C1: an own 0 A not yet read back is kept with the mode; a start in Off with
it writes the 0 A (retried), without it nothing; a start that will not write
warns once when the charger still has the add-on's current. C6: Solar's 30 s
gate also counts from Manual's latest write. C9: an exit also owes its 0 A
when the read-back shows Solar's own value. Rows for C5 and C8 too.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
T4: battery A's power missing, NaN or unavailable, for one cycle (no
write) and for 400 s (no spare, the current held, 0 A at 300 s).
T21 (a): car_cycle on the same projection, guard and reading gives the
same car figure, explains and over in Solar and Manual.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Solar as a second writer next to Manual (carmode.SolarPlan, SolarWriter on
ManualWriter's one write site, safe phase sequence and other-writer watch):
signed spare, Batteries first on the batteries' ratings, the margin, whole
amps rounded down, the 30 s / 1 A rule, start and pause dwells, auto phases,
a one-phase car. Every way out ends at 0 A, retried by EV-04's rule; at
shutdown before the inverters, three tries inside 15 s (D3); start-up and a
returning charger or HA write 0 A first (D2); never over another writer's
hold. The peak guard treats a Solar car as a Manual car (D1 wording). Solar
kWh sensor and card line; select.goodwe_car_sun_first; ev_margin_w,
ev_start_min, ev_pause_min with config, validator, translations, DOCS,
DECISIONS and CHANGELOG.
Checks: test_ev20.py, test_ev20_exits.py, test_ev20_writers.py,
test_ev20_guard.py, test_ev20_long.py, test_ev20_long_car.py,
test_ev20_fuzz.py (harness tools/ev20_sun.py, ev20_kit.py, ev20_day.py);
test_ev03/test_ev04 no longer use Solar as the refused example.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Display only: shadow mode over-limit Why speaks in would-terms; read phases that
differ from the setting say the charger stays; a writer hold says something
else set the charger. EN and NL texts, test_ev14.py.
Co-Authored-By: Claude <noreply@anthropic.com>
A phase that drops out or comes back shifted the compressed current_a tuple and
read as life, so a frozen charger never armed. ChargerReading.phase_a keeps
L1/L2/L3 with None for a missing phase and the life test uses it.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
A refused write on a live charger no longer reads as a stuck reading 60 s
later, so a refused write shows one amber row (charger_refused). A frozen
charger still arms and is still caught.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Review fixes, no logic change:
- T17a now asserts the restore is the first write once the charger is back
(it was only checked to happen at some point); mutant M3 (restore after
SETTLE_S) now turns T17a red.
- T15 now asserts the refused restore is counted once (`fails == 1`);
a mutant without `_failed` there now turns T15 red.
- DECISIONS "The phase sequence" and the carmode docstring reflowed to 79
columns; DECISIONS says D counts as drawing too, as the code does.
Co-Authored-By: Claude <noreply@anthropic.com>
Stage zero counted mode3 B as quiet whatever the power and selected at the
20 s timeout under load. A power reading now decides (under 100 W); mode3
(not C, not D) only without one. Still drawing at 20 s: no select, the
current comes back at once, one failed try, next try PHASE_GAP_S later.
Co-Authored-By: Claude <noreply@anthropic.com>
The fallback (no record yet, or a record of an ended episode) had no check;
reading floor_limited alone there survived test_ev16. Test only.
Co-Authored-By: Claude <noreply@anthropic.com>
car_cycle ends with _car_why_tick (display only: control writes, never reads);
the Why reads the record. Adds read-gap tests (A, B, cover off/on), a long
guard-None test and a lower bound for the hold.
Co-Authored-By: Claude <noreply@anthropic.com>
Control bumps _car_over_ep at each start and end of car_over; the display
ignores a hold of another episode, so a read overlapping the end cannot bring
a stale text back.
Co-Authored-By: Claude <noreply@anthropic.com>
Display only: the 'are at' / 'give all they can' text changes only when the
other state has stood for 180 s (the car_over off hold); SoC unread is never
'are at'. Cleared when car_over drops, on unplug and with cover off.
Co-Authored-By: Claude <noreply@anthropic.com>
Test-only. Two unit checks in test_ev19.py: an honest step with a burst
that moves the meter's house side +/-60 W alarms in base's cycle, and
inside the band (0 W) the car explains at most the step's own cycle;
a car step offset by a burst at the meter is not discounted. They kill
RISE_STILL_W = 500 W and a stillness test without the car term.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
[Major] The rise discount applied to any rise, also one the meter
already shows, so an honest house step answered by one cycle of battery
power alarmed one cycle after base (review repro: T6 step + burst, R+6
instead of R+5). Now a reading above both earlier ones is discounted only
while the meter's house side (held - car; held alone when a car figure is
unknown) moved no more than RISE_STILL_W (50 W) since the last cycle.
Tests: the burst shapes (unit, meter in step and one cycle late;
controller, step at R+5 and R+30, 3 000 / 4 600 W) at base's second; the
"N6 unit" check tightened to the rise cycle; the RISE_STILL_W boundary;
a pin on EV-18's `_car_over_now` (mC); T10 restarts at R-1 and R (mE).
test_ev19: 144 of 144 here, 52 red on 43b0db7.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
EV-15 rig F-B, reproduced on 43b0db7 (tools/ev19_reserve.py, T1 grid). At
the reserve inverter-b goes on following the house, so its output rises
in that cycle. The battery reading shows the rise one cycle before the P1
sample does, and EV-18's house figure (held - car + now - min(now, prev))
counted the new battery power as house load. `_car_need_house` latched:
one PEAK_GUARD_FLOOR_LIMITED ERROR and goodwe_peak_soc_floor at R+1, red
until the guard stopped wanting power.
ctl_car._car_explains_alarm: for the house latch only, a reading above
both earlier readings counts as house only up to the higher of them. The
credit stays the lower of the last two readings. The claim, floor,
setpoints and charger writes are unchanged (342 runs, same digests).
test_ev19.py: T1-T17, T20, N1-N6 of reports/EV-19-test-plan.md; 49
checks red on 43b0db7, 124 of 124 green here.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
Wording only. DECISIONS/EV-04: a contradiction is a meter that answered and
fell short (an unknown reading is none), and it grades no alarm while the
guard's input keeps the figure. ctl_car.car_cycle: the car-over row keeps the
figure only with the cover off.
Co-Authored-By: Claude <noreply@anthropic.com>
- [Critical] The latch set `w = None` before `_car_quarter`, so with cover
off the guard's input (`car_exclude`) counted the car as house and the
batteries discharged. The latch now changes only the figure graded for the
alarm; the car's energy count, the guard's input and the car-over row keep
the unlatched `car_alarm_w()`. Cover-off N4 twins (energy gap, T9(c) liar,
SoC 60 % and at the reserve) give the same commands as without the latch.
- [Major] `corroborated()` is False for an unknown energy reading, so one
missing reading latched a correct figure for the quarter. New
`CarTracker.contradicted()`: only a meter that answered over a whole window
and fell short. R1 (energy entity unknown 1 s at E+200, T2 and T3 shapes):
red for that cycle only, explained from the next.
- Minors: unit checks that a contradiction in our own pause latches nothing
(MF) and that the latch ends with the quarter (MG).
Co-Authored-By: Claude <noreply@anthropic.com>
- [Critical] After a restart or a gap only the rest of the quarter was graded
without the car (`_carq["whole"]`), which dropped the house's own energy
from before it and hid an honest alarm (review repro: house 18 kW then
12 kW, restart at E+310). The rest-only grading is gone: the car is
credited only with energy counted since the start, the rest of what is
done counts as house (base's side). T17b covers it; T17 T2 at E+300 now
alarms from the restart (the conservative side).
- [Major] Owner 2026-11-19: a figure the energy meter contradicted (fresh,
charging, not corroborated) stays untrusted to the quarter's end, also as
the EV-15 stand-in. T9(c): one alarm edge, red to the end; T9(c) is back
in the N5 check.
- [Major] T2c lagging-meter variant (readings 389 W then 800 W, the meter at
800 W): the house latch grades on the lower reading.
- Unit stub: a run that starts mid-quarter has the car counted since the
quarter's start (no restart).
Co-Authored-By: Claude <noreply@anthropic.com>
EV-15 rig F-A: with both batteries at the peak reserve and the car charging,
PEAK_GUARD_FLOOR_LIMITED and goodwe_peak_soc_floor fired at a quarter's start
and stayed red for the quarter, the excess smaller than the car. Two causes,
both held by the per-quarter latch `_car_need_excl`:
- C2: "without the car" assumed the batteries give 0 W from now on, so what
the loop still gives below the reserve counted as house (T2 red on base);
- C1: one cycle with no trusted car figure latched it for the quarter (T1).
Owner 2026-11-19 (Q1-Q3): without the car the batteries keep giving what they
give now (lower of two readings, every cycle); a house need seen with a
trusted car figure stays latched to the quarter's end (`_car_need_house`); an
unknown car figure keeps the alarm only while it is unknown. A car known to
draw nothing (fresh reading, not charging) still grades the house's own need.
After a restart or a gap only the rest of the quarter is graded without the
car. A 0 W figure explains nothing outside our own pause (EV-15). The guard's
claim, floor, setpoints and charger writes are unchanged (N4: 41 runs, same
command digests as base).
test_ev18.py: the test plan's T1-T18, T2b, T2c, N2-N5 (tools/ev18_peak.py:
the real Controller across one quarter edge, N=2 at the reserve).
Co-Authored-By: Claude <noreply@anthropic.com>
The writer runs beside the cycle and the car can stop before the write
returns, so no sequence existed yet and the latch set. Window now opens at
send (zero_sent_at), cleared on return; ends on another writer in the tail too.
Co-Authored-By: Claude <noreply@anthropic.com>
While the add-on holds the car at 0 A for its own phase change, the car's
figure had no corroboration (not charging), so nothing was explained and the
peak-floor alarm fired once. For grading only, the car's fresh, not stuck
figure now stands in for that sequence (bounded: its own waits plus one
corroboration window), ending at once on Off, Stop, shadow, unplug, another
writer or a refused write. car_exclude, the claim, floor and writes unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
Minor bump: car Manual mode (EV-04), car-alone peak alarm fixes
(EV-10, EV-11, EV-12, EV-10b). Two new options with defaults
(ev_batt_cover, ev_mode_start); existing installs need no option change.
Co-Authored-By: Claude <noreply@anthropic.com>
Two checks a mutant survived: crediting the car-made export in the done part,
and taking off the car's quarter average instead of its power now.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The period without the car was clipped at 0 W, so batteries covering the car
were charged to the house and the floor alarm fired (rig F-1). New
car_exclude_alarm keeps the sign of the rest of the period; car_exclude (the
cover-off guard input) is unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
EV-10: the car is the cause when the period without it (projected minus the car's
fresh, corroborated average) is at or under the aim, also with the projection
still under it. EV-11: car_over stays on until the test has been false for 180 s.
EV-12: the tracker's own-write mute opens before the write and runs 15 s from its
return.
Co-Authored-By: Claude <noreply@anthropic.com>
N1 the undo gives the old current back (clamped) in shadow mode; DECISIONS records it as the one write shadow mode allows.
N2 the corroboration looks back to a stretch with at least 40 Wh expected (60 s at 2.4 kW and up, 104 s at 1.38 kW).
L4 the current comes back 10 s after the phase select returned, also when it was refused.
Co-Authored-By: Claude <noreply@anthropic.com>
M1 the writer ignores a reading taken before its latest confirmed write.
M2 a refused phase select gives the current back and stops after 3 tries (amber row).
M3 Off, shadow mode or a control/safety stop before the select undoes the change.
M4 the restore on shutdown (and the undo) is clamped.
M5 the car's power reaches the alarm path only while the charger's energy meter agrees with it.
L1 fuzz other-writer branch reachable and shown to run. L2 one wording. L3 Batteries-help-off text.
Co-Authored-By: Claude <noreply@anthropic.com>
Off and Manual (runtime state, Home and Home Assistant): the current (6 A to
the clamp) and the phases (1 or 3) are written once per user change through
the safe phase sequence, read back within 10 s, clamped to
min(ev_max_a, station limit, entity range). Shadow mode gates the writes.
The car's fresh power goes to the peak guard's alarm path: no false "Load too
high" or "Battery stopped limiting the peak", one grey notice per session.
ev_batt_cover and ev_mode_start options, peak line "set by the car", HA
entities, sim writes, DOCS, CHANGELOG, test_ev04.py.
Co-Authored-By: Claude <noreply@anthropic.com>
- MAINT-28: say the hold is for two inverters (the code gates it on N >= 2).
- EV-03: "no longer buy energy for the car" (the profile is a 7-day median).
- TEL-19: plain wording for the PV sensor point.
- Known issues: add TEL-20 (DOCS names a car sensor id HA does not create).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Bump version to 0.23.0 and fold "Not in a release yet" into a new
0.23.0 CHANGELOG section (MAINT-28, CI-17, EV-03, CI-18). Four new
options (ev_*), all with defaults; no option change needed.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The selector reads the graph, and run-affected.sh runs the tests, from the
working tree, so a --base/--head range is only right with the head checked
out. The CI image is built from the merged tree, so an ENV CI_ONLY in its
Dockerfile would make the gate partial; test_affected_tests.py now fails on it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A test first reached as text (a pattern reader) was never expanded again when a
later path reached it by import, so a test importing it was missed. Expanded and
reached are now tracked apart; the empty diff selects the safety set. Test added.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- .gitea/ci/affected_tests.py: which test_*.py a diff reaches (static import
graph plus names in strings, transitive), a fixed safety set, SELECT ALL for
anything it cannot map. .gitea/ci/run-affected.sh runs the selection in the
CI image. run-tests.sh takes CI_ONLY for that; checks.yml never sets it and
test_affected_tests.py fails if it does. The merge gate still runs every file.
- test_modes_p4 -> p4/p4b/p4c/p4d, test_safety126 -> +b, test_safety125 -> +b:
same check lines, none dropped (146, 35, 45 before and after).
- run-tests.sh: 10 workers instead of 6, new longest-first order.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
POWER_UNITS is now derived from _W_PER, so the start-up probe and the
reading cannot drift apart. No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- every HA power unit is accepted and converted (mW, W, kW, MW), in the probe
and in the reading
- a power entity that answers in another unit, with no unit, or not as a
number makes the reading unavailable: after 30 s it is "Charger not
reachable" (amber row, WARNING, notification after 5 min), with a Why that
names the cause (EN and NL)
Co-Authored-By: Claude <noreply@anthropic.com>
A charger with no usable power entity is refused as "not set up", like a
missing setpoint, read-back or state entity, so House and the house profile
behave as with no charger. An entity that is merely unavailable at probe time
is still the unreachable path. NL: help text "met rust", chip "Laadpaalstoring".
Co-Authored-By: Claude <noreply@anthropic.com>
- CarTracker.car_w returns None when the current reading carries no power
(power entity unavailable or in a non-power unit); it can no longer raise
into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().
Co-Authored-By: Claude <noreply@anthropic.com>
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py
Co-Authored-By: Claude <noreply@anthropic.com>
The two fixtures ran their cycles at _SRC_NOW but set rejected_since from the
real clock, so the cycle saw inverter-b live while live_units() saw it stale.
Both now use _SRC_NOW, and a check asserts both clocks agree. run_cycle's
comment no longer claims ctl_cycle.py:49 is the only clock read.
Co-Authored-By: Claude <noreply@anthropic.com>
c_src's telegrams were laid up to one datetime.now(); each cycle() then read
the real clock again (ctl_cycle.py:49). Under --cpus 0.25 a cycle takes ~1.3 s,
so by the 23rd sweep cycle the last telegram was older than max_hold_s (30 s),
the guard counted the gap and filed peak@site. The cycles now run AT the
fixture's own instant. Test only; the exact-set checks are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).
Co-Authored-By: Claude <noreply@anthropic.com>
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.
Co-Authored-By: Claude <noreply@anthropic.com>
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.
Co-Authored-By: Claude <noreply@anthropic.com>
release/1.0 reverted #247 (7bc8ad2). The tree is taken as release/1.0 here; the next two commits revert that revert and re-apply this PR's four fix rounds, so no history is rewritten.
Co-Authored-By: Claude <noreply@anthropic.com>
- SAFETY-136 row: the gain is at 10 s late; at 15 s a rig test sent more.
- SAFETY-111: the cycle needs more than 4 nights; the 36 h limit ends it.
- MAINT-28: rig counts were 393-468 flips per 45 min, not one figure.
- MAINT-26 / MAINT-25: the next try is the first start hour after the wait.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner 2026-11-13 ("ok max", relayed by the manager): while the pause holds,
the pack in maintenance CHARGE gives at most the largest floor the guard
claimed in the quarter. The cap is now that pack's own part of the floor
(the floor less what the other units are placed at, split without the cap),
the largest in the 15-minute period, kept per unit (`_m28_hi`). 0 W while
the guard holds it at its reserve. test_maint28b: SoC check stated against
the owner-accepted give (0.70 point, measured 0.64); both-packs-able tests
(B on Cheap hours, B on Solar first); per-unit state and the one-slot
arbitrate. test_maint28 unchanged (5925 W). Pins: test_safety84
n2_charge_banked, test_packshare's one-resolve AST pin (a second call with
the same weights).
Co-Authored-By: Claude <noreply@anthropic.com>
test_maint28 quarter bound back to aim + 1 W (now 5925 W; the guard alone landed
5960.1 W): the pack's limit is the largest floor the guard claimed in the 15-minute
period. A pack in peak_guard.held (the guard places its claim on the others) gets
0 W. test_safety84 n2_charge_banked re-pinned again, its banked quarters asserted
under the aim. New test: guard claims on the other pack only.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner go 2026-11-13. The pack in maintenance CHARGE gets a unit limit with hi
= the guard's own floor while the pause holds, at any SoC (replaces the
under-reserve limit). Sim 45 min: A give 2.39 -> 0.02 kWh, SoC 49.0 %, charge
back 4 s. test_safety84 n2_charge_banked re-pinned (192 of 480 rows),
test_maint28 quarter bound to the month peak. Tests: test_maint28b.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Rig FAIL (TEST-23, f3f9483). F-1: the hold ended at each guard step because
grid + site_batt_w added a new meter reading to a battery reading up to 10 s
old. It now ends only when no battery reading may pre-date a step up of its
command (Controller._batts_settled()). F-2: while the pause holds, a pack in
maintenance CHARGE at or under its peak reserve is limited to 0 W, so it gives
only what the guard claims for the peak. Sim: Lag.batt_period_s (a held 10 s
register). Tests: test_maint28b.py. DECISIONS updated.
Co-Authored-By: Claude <noreply@anthropic.com>
homeview.maintenance_runs() ignored backoff_until(); it drew a cycle every
night of the wait. Now no run and a plain line (EN, NL). test_maint25.py.
Co-Authored-By: Claude <noreply@anthropic.com>
The mode trade still lets a SAFETY-73 probe (PROBE_W alone) go on while a pack
is in its maintenance CHARGE phase; test_opt20.py g7 pins it. ch_ch_maint
digest moved (B no longer grid-charges beside A's charge).
Co-Authored-By: Claude <noreply@anthropic.com>
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.
DECISIONS/SAFETY-135-young-period.md, test_safety135.py.
Co-Authored-By: Claude <noreply@anthropic.com>
F1 the on-change case is tested as slow, F2 override and direction checks,
F3 the 3.75 s rule in the texts, F4 the quarter figures and the live note.
No behaviour change.
Co-Authored-By: Claude <noreply@anthropic.com>
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.
Co-Authored-By: Claude <noreply@anthropic.com>
test_safety118's "size rule is gone" and test_validate's "no numeric
maintenance_* fallback" read app/main.py only; the code they guard can now
sit in app/ctl_*.py, where a regression passed unseen. Both read
main_files.source() for main.py now. Tests only; no app change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Router T241: the comments commit had put new rationale into
MAIN-orchestration.md and cut comment lines that the note at 56fc41f did not
hold.
- DECISIONS/MAIN-orchestration.md is the 56fc41f text plus the one sentence
that the Controller is split into app/main.py and app/ctl_*.py.
- Comments whose content is not in a DECISIONS note at 56fc41f are back in the
code verbatim: MAINT-05 one config, the SAFETY-02, SAFETY-42/34,
SAFETY-30 site half, SAFETY-31 and SAFETY-18 latch blocks in __init__, the
_grade_store_migration docstring and comment, the trade_power_w docstring,
the rows.py docstrings.
- Kept: cuts of text already in the note, the SMA-10 / SAFETY-137 / SMA-2
pointers, the SAFETY-32 line fix.
No code change: maint21_same_ast OK, maint20_same_code -OO same.
Co-Authored-By: Claude <noreply@anthropic.com>
No code change: tools/maint21_same_ast.py and tools/maint20_same_code.py HEAD~
both print OK, and the -OO code objects are the same.
- Trims 56 comment and docstring lines (2088 -> 2032) in app/main.py and the
new files that only restated their MAIN-orchestration.md bullet, each cut to
its first sentence and a pointer. What the cut comments said and the bullet
did not is now in the bullet: why a SAFETY-02 latch is restored, why the
SAFETY-30 site check is not armed at one inverter, the SAFETY-18 re-derive,
the MAINT-05 one-config rule, the OPT-09 sizing rules, the "no plan" row,
the 5 400 s age bound, and the guard being the only latch repair.
- Adds the missing DECISIONS pointers on the SMA-10, SAFETY-137 and SMA-2
comments (FALLBACK_BUDGET_S, write_setpoint, _await_inflight,
_release_last, the retry wait, the failed-release branch, release_zero_sent,
the in-flight write, the stop_event hand-back, the SMA-2 read and driver).
- DECISIONS/SAFETY-32: the stale `main.py:932-936` now names
Controller.pack_floor_soc.
- main.py's docstring and import block say where the Controller's parts are.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. TasksMixin: run_control, run_tariff_refresh, fresh_tariff_plan and the store-migration grade. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. StatusMixin: checks, status_payload, forecast_payload, publish, mqtt_command, handle_action, why_words. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. AlarmsMixin: the check_* alarms and the loop-alarm helpers. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. CycleMixin: cycle() and _shadow_settle(). cycle() is not cut up. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. TradeMixin: trade sizing, the mode runs, the day plan, the peak floors, drain and charge limits, pack actions. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. WritesMixin: write_setpoint, write_refusal, _write_unit, _hand_back, the refusal evidence, heartbeats and the site release/zero commands. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves the methods named in the card and the constants only they read out of app/main.py unchanged. InputsMixin: read_inputs, _read_unit, live_units and the other readers of the meter, packs, PV and forecast. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Moves why_raised, why_key, tariff_plan_row and arbitrage_row out of app/main.py unchanged. main.py imports them, so app.main still exports them. tools/maint21_same_ast.py: OK.
Co-Authored-By: Claude <noreply@anthropic.com>
Prepares the split of app/main.py's Controller into files by job, with no app
change. tools/main_files.py gives a test the text and the AST of main.py plus
the files split from it, and `live`, which sets a global in every file whose
functions read it (and raises when none does). Tests that read main.py's
source, and tests and replay tools that patch a main global (datetime,
compute, resolve, _mono, WRITE_BUDGET_S, ...), go through it, so they pass on
this layout and on the split one. test_split_patches.py fails when a test or
tool patches an app.main attribute that main.py no longer reads, or that
another file also reads. tools/maint21_same_ast.py proves every function,
method and module-level assignment of main.py at the base is found unchanged
in its new file.
Co-Authored-By: Claude <noreply@anthropic.com>
- check_peak_floor_limited: restore the SAFETY-25 line (the reserve sentence is
in messages.peak_reserve() on every branch, unreadable SoC included).
- Three status-page comments that no longer said anything (SAFETY-20 row,
AC 5 delivery row, banner-vs-text) now say their rule in one line.
- tariff_refresh_wanted docstring: no orphan "TARIFF-24)" line.
- MAIN-orchestration.md: blank line before the first heading.
- MAIN-orchestration-archive.md: refilled intro; says how to find a section
from a main.py pointer.
No code change: maint20_same_code.py 16029d7 -> SAME CODE, -OO same.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Nine conflicts in app/main.py, all in comments around new code: every code
line is release/1.0's, every comment follows the part 2 rule.
Co-Authored-By: Claude <noreply@anthropic.com>
SAFETY-136: the line said 10 to 15 s late is not caught, then that 15 s late
is caught after about 4 minutes. It now says 10 s is not caught and 15 s only
after about 4 minutes, as the card says.
SAFETY-138: the 30 s timer that zeroes a late write is the ESPHome board's
watchdog (README), not the inverter's own.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Minor bump, no option changes. Folds "Not in a release yet" into a new
0.21.0 section, adds the contents table for the nine merges on release/1.0
since master 0.20.1, updates the known issues, and rewrites the 0.20.1
SAFETY-128 known issue to say it ships in 0.21.0.
Co-Authored-By: Claude <noreply@anthropic.com>
The 0 W of shutdown and of the Stop button now waits (bounded, 2 s) for a
write already on its way to the same unit, for every driver, GoodWe included.
Once shutdown has begun, cycle, heartbeat and safety-stop writes are dropped
right before the write is created. One shared wait (_await_inflight) serves
the 0 W and SMA-10's _release_last.
Co-Authored-By: Claude <noreply@anthropic.com>
The NL default for a hand-back driver without words (handback._BACK_NL) was
changed to "de eigen sturing" in round 2 at the PR #239 review's request
(comment 2495: the article as in the generic clause). The brief does not name
it, so DECISIONS now says where it came from and a test checks the exact Dutch
sentence. No app code change.
Co-Authored-By: Claude <noreply@anthropic.com>
When control takes the unit again, release_fails, release_retry_at and
release_zero_sent are reset, so the next Stop is a new streak with its own one
0 W, error line and event. Tests: a streak that Start interrupts without a
recovery; a driver that overrides release_fallback(). _BACK_NL "de eigen
sturing" (round 2) is kept.
Co-Authored-By: Claude <noreply@anthropic.com>
When release() fails (False, raises or hangs past RELEASE_BUDGET_S) the unit
gets one bounded write(0) through the new Driver.release_fallback() hook
(default write(0)), then nothing more, so the inverter's own fallback timer is
not reset. The release is retried once per heartbeat, not on every idle
write. One error line and one action-log event per failure streak, one line on
recovery. Dutch default "terug naar de eigen sturing". DECISIONS says what a
unit is left at.
test_messages.py: the RELEASE_BUDGET_S data entry is gone again (the line
that needed it is gone).
Co-Authored-By: Claude <noreply@anthropic.com>
A driver now says whether its release() hands the inverter back
(Driver.hands_back; GoodWe is False, so release() stays write(0) and the
Controller never calls it). command_site_release() sits next to
command_site_zero(): the Stop button and shutdown() (so SIGTERM, restart,
control task death and a late config refusal) hand a hand-back unit back,
once, and zero every other unit as before. Safety stops and refusals still
hold 0 W for every unit. Shadow mode releases a hand-back unit. After a
release nothing is written to the unit (heartbeat and cycle included) until
control starts again. release() is bounded by RELEASE_BUDGET_S (= the write
budget), runs concurrently per unit, and a raising or hanging release on one
unit does not stop the others.
The "set to 0 W" sentences for Stop, restart, shadow mode and the stopped
banner are built from the roster (app/handback.py, EN and NL, words from the
driver); a GoodWe-only roster keeps every old literal. A handed-back unit
shows "Back under <its control>" on Home.
Existing test edited: test_messages.py (two classification entries for the
CRITICAL line that moved into a roster builder, and the new release bound).
Co-Authored-By: Claude <noreply@anthropic.com>
Owner decision 2026-11-07: clients see nothing new until SMA-4. config.yaml,
translations, labels and the page layout are back to 23ff9d0's. The validation
of the keys stays for callers that skip the schema.
Co-Authored-By: Claude <noreply@anthropic.com>
app/drivers.py holds one Driver per roster entry (configured, actuator_id,
limits, read, write, release, probe, link_stale_s, batt_bound, settle_s, brand,
words). GoodWeEsphomeDriver makes the calls the code it replaced made, in the
same order. Inverter gets driver; has_writer, is_live and link_note read it. The
SoC/power read, the write, the device range (run_control, amain, the settings
panel), rule 2 per unit and the SAFETY-28 census go through it.
setpoint_entity is optional per entry beside driver, host, port, unit_id and
maintenance; only goodwe_esphome is selectable, the rest are checked and unused.
Co-Authored-By: Claude <noreply@anthropic.com>
Before the bell ends it replaced today's Home line and the event log with
the kept-for-tonight wording. stand_in() docstring covers the tomorrow case.
Co-Authored-By: Claude <noreply@anthropic.com>
One stale Forecast.Solar tomorrow sensor dropped the whole OPT-17 sum from
17:54 to 20:00. Today readings and the OPT-34 morning rules are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
At a 5 s meter the slow meter fit now finds 30 s late first, and the hold leaves
the batteries' fit nothing to measure, so the row says it without a figure.
Co-Authored-By: Claude <noreply@anthropic.com>
The meter's delay fit needed 16 new values in 60 s, so at the owner's 5 s P1
only the batteries' fit ran and 30 s late was found after about 3 minutes
(export to -420 W). A meter that slow is now also fitted over 120 s; it calls
a delay late only over 16 s, on two fits in a row, with the same corroboration
as before, and never ends a verdict, so a slow battery (R2-1) runs as before.
Found about 90 s after the start, export above -200 W. 10 s late at a 5 s
meter is not found (nothing swings; it cannot be told from a 10 s battery).
Co-Authored-By: Claude <noreply@anthropic.com>
The cheap-run roll (cheaproll._Charge) shared the peak room by rating, control
shares it by room left to full (packshare.weights). With unequal levels one
battery's drawn block ended too early (rig F-1). The roll now uses
packshare.weights over the simulated levels, each battery capped at its rating,
a full one dropping out. test_ux77 gains two unequal-level walks and a
by-rating mutant; its walks model control's split by room too.
Co-Authored-By: Claude <noreply@anthropic.com>
The cheap run is sized at the full rating, so under the peak limit a battery is
still short when it ends, and control plans the next run then. Home drew only
the run under way. `cheaproll` rolls the run on the way control does
(`modetrade.energy()` + `priceruns.plan()` at each run end, lifted from
`dayview._levels()`), reading the levels at the charge power the peak limit
leaves (peak aim less the house, else the rating). `homeview.mode_runs()` and
`price_windows()` use it for today: the grid block, the Today line and the
chart's cheap bars run to where control stops, each battery's block to its
own stop. Display only: no control change.
test_ux54: today's grid block of the night-before scenario now follows the roll.
Co-Authored-By: Claude <noreply@anthropic.com>
Brings OPT-36 (#229) and TEST-37 (#231) onto release/1.0, which keeps
SAFETY-128 (#228). No textual conflicts. CHANGELOG: the SAFETY-128 entry
moved out of the released 0.20.0 section into "Not in a release yet" above
## 0.20.1; the 0.20.0 and 0.20.1 sections are identical to master.
Co-Authored-By: Claude <noreply@anthropic.com>
The stale_live scenario stores a latch ending 2026-11-04 07:15 CET. The first
Controller was built before the datetime patch, so Controller.__init__ judged
that latch against the real clock and it expired on 2026-11-04. Build it after
the patch (clock = scenario start), as the restart path already did. Test-only.
Co-Authored-By: Claude <noreply@anthropic.com>
SAFETY-132: the 9.6 kW is the charge the add-on asked for in a test,
not a measured grid figure. SAFETY-133: the quarter also ends over the
3 500 W limit; the guard sees the load late (0.20.1 has no lateness check).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Patch bump: OPT-36 (Leftover solar counts Cheap hours only and Solar first batteries). No option changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Review F1: a slot after B's run counts only if no slot from the expensive
hours on is cheaper (control plans B's charge left in the cheapest window
ahead), and x 0.95 of B's charge is stored. Three-price night: 1ac7fe9 left
the expensive hours 2.61 kWh short; now 0.
Review F2: a Solar first battery's drain until the expensive hours reads each
hour at no less than the night base (the profile is net of the sun). Read net,
a dark morning drained the battery the plan still counted; A's level fell,
the cheap run moved and was lost before it started (+0.40 EUR per 3 days).
The two real-price replays now cost what 0.20.0 does.
F3: the ux54 sweep's peak limit is 15 kW (the option's top). F4: the rest
comes from the grid (EN/NL). F5: CHANGELOG and DECISIONS wording.
Co-Authored-By: Claude <noreply@anthropic.com>
The run is sized at the batteries' ratings, not the peak limit, so a run too
short to fill a Cheap hours battery is planned again later in the night.
Counting that run alone made B's give grow through the night and A's level
fall after A had bought (round 2: 55 -> 69 -> 41 -> 37 %, A to 56 %).
dayplan._cheap_give_kwh() now also counts the later firm slots before the
expensive hours that a run would still be worth charging in (price + the
spread control asks at most the give run's dearest slot); the Controller
passes the slots and the spread.
test_opt34: back to the original house shapes, fixture and expected values.
B is Off in the nights that test A's level (a Cheap hours B now covers
these hours); B's checks run in new `_b` nights; the 03:00 check runs in a
night from midnight; tail starts A at 60 %; late_fresh reads the kept 6.0.
test_opt36: slot cases, a whole night on one figure (level never moves),
F-1 with B counted (raised level reached and held). test_ux54: the run end
is read from the plan and asserted (02:30); the F1/F2 sweep uses a peak
limit that does not bind and reads a level shown as the target as at it.
Co-Authored-By: Claude <noreply@anthropic.com>
The silent and fresh nights diverged only because the test's fresh sensors
kept reading the evening's 0.4 kWh 'left today' after midnight, while the
kept figure is the 4th's 6.0 kWh (solarfc.Hold.stand_in, as_today): two
different shortfalls (16.5 and 12.7 kWh) that A's ceiling hid until B was
counted. Fresh sensors now read 6.0 after midnight, so fresh and kept are
the same figure; the 0.3 tolerance is back, the other exact values are
recomputed. test_ux54 literals are recomputed too.
Co-Authored-By: Claude <noreply@anthropic.com>
Review B1: the meter fit took repeating house loads (ovens, a heat pump)
for late readings on healthy 1-2 s sites, about 9 % of the recorded
house. B2: at a 5 s meter it never ran. M1: no hysteresis. M2: an
unbounded check.
lateness.Delay now fits how long each battery's reading takes to show
its own request, which the house does not move, from the 1 s reads
(read_inputs -> Answer.watch). The meter fit stays for speed at 1-3 s
meters, but counts only when an ask was slow to start and no battery
fit said on time. Late from 9.5 s after 2 fits, on time under 6.5 s,
dropped after 120 s without a fit. Fits are bounded (a few ms).
Readings on time: no verdict in any reviewer scenario (22 shapes at
1/2/5 s meters, 7 harm runs) nor in 2 days of the recorded house at
1, 2 and 5 s ticks; digests equal to 77fe31b. Late: found 36-68 s after
the start at 1-2 s, about 3 min at 5 s. The row gives the batteries'
delay, or no figure while only the meter has shown it.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
With Cheap hours B counted, A buys only what B cannot reach. The OPT-34
night scenarios use a 1.6 x larger house profile, and the ux54 tab scenarios
a 4.8 kW evening (ux54_scenarios.make(evening=)), so A still charges; the
hard-coded levels become relations.
Co-Authored-By: Claude <noreply@anthropic.com>
Live 0.20.0: A (Leftover solar, 60 %) charged to 95 % while B (Cheap hours,
94 %) already covered the expensive hours. dayplan.plan() now takes off the
shortfall what Cheap hours batteries will hold when the hours start (the
ceiling or what their cheap run reaches under the peak aim) and what Solar
first batteries will still hold after the night's use. Home reads a give
block after the planned charge, plan_cover() is the plan's own figure, and
the Why line says other batteries cover.
Co-Authored-By: Claude <noreply@anthropic.com>
Readings that Home Assistant delivers late but still changing passed
every staleness gate, so the loop corrected again each cycle an error
its last command had already fixed (10 s late: the give run swung and
exported to -1.9 kW), and the peak guard pushed to the inverter limit
on the same late figures (OPT-34 F-2).
app/lateness.py fits how long after a power request the meter shows
it. Over 8 s the readings are late: a request the battery reading has
not answered holds the loop (it may not lead the reading by more than
100 W) and caps the peak guard at what stands; unanswered for 23 s it
holds, then 0 W after stale_input_s. An amber row and one log line per
episode say so. With readings on time nothing changes (digests equal).
DECISIONS/SAFETY-128-late-readings.md; test_safety128.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- The OPT-23 headline said a daily-total forecast is now counted right by
day; OPT-30 (known issue) still over-counts by day. Say what changed.
- CI-15: 16 min was one run; runs took 16 to 24 min.
- UX-75: quote the page text as it reads.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
After a fresh today reading in the night (02:00 on the rig) went stale
(05:00), Hold.stand_in(as_today=True) served the 17:05 "tomorrow" figure
again until 06:00: the plan went back to 95 %, the latch took it, and
Leftover solar charged back up. read_sum() now skips that stand-in once
every today sensor has given a fresh reading for the day
(Hold.replaced()); the stale newer reading follows the OPT-27 rules.
Co-Authored-By: Claude <noreply@anthropic.com>
Comment, docstring and DECISIONS only (same-code script OK; python -OO
bytecode now identical for all six files).
- peakguard.charge_room_w: one-line docstring + SAFETY-125 pointer (cut whole).
- peakguard.shaping_suspended: keep 'the one place this conjunction is
written; do not inline it'.
- price_forecast module note: an hour with no price and no yesterday is left
out, never filled (test_price.py 14d cites the module note for it).
- Refill comment blocks the cut left ragged; DECISIONS pointers on one line.
- FCST-04 note: _yesterday_of(), not _previous_day(); FCST-03 note: the 49
stronger cases are why the rule is a real change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- F1: an expired latch is dropped whatever the run state; plan_targets() and the
store loader ignore one that has ended (no stale latch after a restart).
- F2: the "charge goes on" line only while a cheap run is on.
- F3: a battery that is off or no longer Leftover solar leaves the latch.
- F4: a run carries the latch on only if it starts by the bell start (06:00
local) after the latch began (manager's call, 2026-10-31).
Tests: test_opt34 scenarios stale/stale_live and part 5; test_modes_p4 asks at a
moment inside the latch.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
test_opt34.py part 4 drives Controller._latch_charge() directly: a battery
that leaves the plan is dropped at once, does not rejoin while nothing
charges, an empty latch is cleared from the store, and the screen says the
charge goes on only while the latched battery is below its level. Catches
two reviewer mutants that survived the round-2 tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While a forecast is present and the cheap run holds, the night-charge latch is
rebuilt from the plan: a latched battery takes its current level whatever its
role this tick (a fresh figure may lower it below the SoC), one that left the
plan is dropped, a new one comes in only while it charges from the grid.
Test: a fresh brighter figure lowers A below its SoC, the sensors go quiet, A
does not charge back up. CHANGELOG summary says two fixes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
With the forecast sensors silent from 17:05 the kept evening figure ended at
midnight + 3 h, in the middle of the night grid charge, and Leftover solar's
planned level went with it (rig: A 49.8 % against 79.9 %).
- A night grid charge that has started keeps its planned level when the forecast
goes (Controller._latch_charge, store key night_charge_latch), and the narrow
price gap with it (weather_held). A fresh figure still moves the level.
- The evening's tomorrow figure is today's until the bell starts (06:00 local),
up to 15 h old but only if it was usable at midnight (solarfc.Hold.stand_in).
- Screen: "No solar forecast now. The charge under way goes on to its planned
level." (EN/NL) while a latched battery is below its level.
- test_opt34.py (whole nights through the real control cycle, mutants), test_opt27
and test_modes_p4 adjusted to the new window and the kept level.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Text only (DECISIONS, DOCS, CHANGELOG): a step load alarms on the same cycle
as before; a steadily rising load alarms a little later; with peak_margin_w 0
a period can end up to 10 W over the limit without this alarm, as for 'Load
too high' (SAFETY-81). Owner accepted 2026-10-31.
test_safety126.py part 2: after a real overrun ends, _peak_landing()'s latch
is reset and the night's later landings are quiet (review F3).
Co-Authored-By: Claude <noreply@anthropic.com>
During the night grid charge under the peak reserve the guard alarmed
(ERROR PEAK_GUARD_FLOOR_LIMITED, "Battery stopped limiting the peak") and the
Batteries "Why" said "The peak limit needs power" at quarter ends, while every
quarter landed on the aim. The charge lands the period 0-7 W over the aim and
excess_w()'s 900 / remaining turns that into tens of kW in the last second;
with nothing able to give, check_peak_floor_limited() alarmed on any
wanted > 0.
Each cycle the guard wants power, _peak_landing() asks misses_aim(): with the
batteries at 0 W, does the period end more than ALARM_MISS_W over the aim? If
not, the decision is within_aim: no reserve alarm, no red peak row, no "Why"
peak. The claim and the commands are unchanged. A real overrun under the
reserve alarms on the same cycle as before.
Co-Authored-By: Claude <noreply@anthropic.com>
F1: the evening rule has an age limit (KEPT_MAX_AGE_S).
F2: the evening bound is the next local midnight (_bounds), right on 25 h and 23 h days.
F5: test that old days are dropped from the stored hold.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes off the forecast is still read and shown (Settings,
Simple, and the Forecast tab), but no plan uses it, so "used for tonight's
plan" was not true there (UX-53). "Kept for tonight" is true in every
shape. NL "vanavond" read wrong after midnight; "vannacht" covers the
whole night. DECISIONS' "modes off: nothing reads the sensors" corrected.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Hold.stand_in(): day0 <= now < day0 + 3 h. A tomorrow sensor is asked with
day0 = the next midnight, so the upper bound alone was true all day and a
figure stood in at any hour. test_opt27.py covers daytime tomorrow outages.
Co-Authored-By: Claude <noreply@anthropic.com>
test_modes_p4.py: 'the forecast is lost mid-run' now loses it for good (a hold
that never covers); a second scenario is the same loss with the hold, which
keeps Leftover solar charging. test_opt27.py: a failing check no longer hides
the ones after it.
Co-Authored-By: Claude <noreply@anthropic.com>
Forecast.Solar's sensors stop updating in the evening, so at night every such
site had no forecast: the night cheap run needed 1.5x the cycle cost and
Leftover solar planned nothing. One missed poll also dropped it at once.
solarfc.Hold keeps the last fresh reading of each sensor, for the day it is
for. A missing or stale sensor is covered by it for up to FRESH_S (a short
outage), and from the end of the bell (20:00) until local midnight + 3 h
however old. A tomorrow figure is tomorrow's until midnight and then today's;
a today figure is only today's. Stored in the controller's store
(solar_fc_hold), so an evening restart keeps it. The forecast line says
'Solar forecast read 17:05, used for tonight's plan.' (EN, NL).
test_tariff24_weather.py runs with a hold that never covers: it tests what the
plan does when the forecast IS lost.
Co-Authored-By: Claude <noreply@anthropic.com>
UX-54's Forecast tab (release/1.0) re-plans tomorrow's cheap run as control
will, with the gap `required`. It still added the "no weather" x1.5 always,
while control (TARIFF-24, from master) drops it when a forecast is read. In
the UX-54 scenarios the tab asked 0.225 where control needs 0.15. It now asks
`arbitrage.weather_uncertainty(True, c.solar_fc)`, so the two agree again, as
they did on release/1.0 alone. Display only; no control change. The tab's
blocks in every UX-54 scenario, every 2 h, are identical to release/1.0.
test_ux54.py pins it (the old line fails it). The TARIFF-24 DECISIONS note
names the tab as the fourth place that reads the rule.
Co-Authored-By: Claude <noreply@anthropic.com>
- TARIFF-24 DECISIONS: the hold keeps a Cheap hours charge; a Leftover solar
battery still stops without a forecast (it has no planned level, still true
after OPT-28: `dayplan.plan()` returns None and `charge_to()` gives None).
Adds "a run that has started runs to its end" for a give run begun in a hold.
- CHANGELOG 0.19.2: "when the period is over" -> "when the period would go
over the limit".
Co-Authored-By: Claude <noreply@anthropic.com>
Part 6 of test_tariff24_weather.py, the review's probes R4 and R5:
- R4: a forecast lost while only the day's give run is under way holds to
that run's end (22:00) and no further; the night's cheap run then needs the
wider gap. Pins the `solar_fc is None` return in `_wx_track()`: without it
the hold chains into the cheap run and B charges (mutant M2, now red).
- R5: a give run that starts during a hold runs to its end (`keep_started()`),
with no grid charge after the hold. Behaviour unchanged; a give run not kept
goes red.
Co-Authored-By: Claude <noreply@anthropic.com>
With master merged in (TARIFF-24), a forecast replaces the 1.5x widening, so
the shipped cost 0.10 is now the whole gap with a forecast. test_ux54.py's
modes-on scenarios were written for 0.15 and 21 of its checks failed on
release/1.0 + master (they pass on release/1.0 alone). They now set the cost
to 0.15 where they have a forecast: the same gate as before. Scenarios with no
forecast (nofc, stale) and modes off keep 0.10, widened as before.
(cherry picked from commit 665653517c, branch OPT-27)
Co-Authored-By: Claude <noreply@anthropic.com>
Brings in 0.19.1 (TARIFF-24) and 0.19.2 (SAFETY-125). Git merged every file
without a text conflict. config.yaml's version becomes 0.19.2, the newest
CHANGELOG section: test_version_gate.py (PKG-14, 11b) requires the two to be
equal, and release/1.0 took 0.19.0 the same way (#207). The 0.19.1 and 0.19.2
CHANGELOG sections come in as history.
Co-Authored-By: Claude <noreply@anthropic.com>
With A on Leftover solar and B on Cheap hours (the dynamic scenario, and the
owner's planned setup), the line said "The batteries cannot hold it all. The
grid covers N kWh", while B holds a full charge for the same hours. It now
says "The expensive hours need more than Leftover solar can hold. The rest,
N kWh, comes from another battery or the grid." (NL likewise). DOCS,
DECISIONS and the dayplan/homeview docstrings say the same. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Its status page says "Meter: no reading for N seconds, limit 30 seconds" when
N passes 30; N is about half the file's run time. It failed alone under
--cpus 0.15 (94 s), in a loaded local parallel run (103 s) and in a loaded CI
run (112 s, run 1434). Idle it takes ~25 s. No test file changed, so it runs
alone after the parallel batch, like test_loop.py and test_freeze.py.
Co-Authored-By: Claude <noreply@anthropic.com>
OPT-23: a state-only forecast is read from now for every span
(Forecast.between since=), so the plan's per-hour sun adds up to the day's
figure, today and tomorrow. Hourly splits are unchanged. The Forecast tab
reads spans the same way.
OPT-28: a Leftover solar battery buys, from the floor, the sum over the
expensive hours of max(0, house - trust x sun), / EFF. Several Leftover
solar batteries hold it together by capacity, the ceiling passes the rest
on, and what none can hold is said (Plan.uncovered_kwh). Home's grid block,
the Batteries line and the mode help (EN + NL) say the level, what it
covers, and that Leftover solar buys only what the sun will not give.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The serial loop summed 3 557 s on SAFETY-125's run and passed the runner's
60-minute cap. The loop moves to .gitea/ci/run-tests.sh: xargs -P 6, longest
files first, then test_loop.py and test_freeze.py (TEST-30 / CI-06) alone on an
idle machine. Same PASS/FAIL lines, CI: echo, tail -40, :ro mount,
PYTHONDONTWRITEBYTECODE=1, GOODWE_REQUIRE_HWSIM=1 and NO test_*.py FOUND guard;
one output file per test file; any failing or unreported file fails the job.
timeout-minutes 70 -> 40, comment corrected. No test file changed.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner 2026-10-29: fix N=1 in this hotfix. _charge_headroom() no longer
returns early at one inverter, so the N=1 cheap-window maintenance charge
is held to charge_room_w() as at N=2; SAFETY-84's site-stop rule stays N>=2
only (at N=1 such a stop outranks the shaping anyway). The guard no longer
steps in and gives power at each quarter's end during that charge.
test_safety125.py: N=1 maintenance on 5 s and 10 s meters with late
readings, with and without a banked peak; the row in an N=2 maintenance
charge and in shadow mode; edge cases (blind past the hold, a start
mid-quarter, the summer-time change, the forecast in W, a 10 s meter, the
last second). test_safety84/87: three N=1 pins move. test_safety119: its
quarter-edge hand-back runs keep the old N=1 sizing as a fixture, plus a
check that with the new sizing nothing hands back. CHANGELOG, DECISIONS,
DOCS follow.
Co-Authored-By: Claude <noreply@anthropic.com>
- The over-the-limit rows ran over STYLE's 15 words (EN 16/19, NL 16/21)
and two Dutch Home sentences over 12 words; they were not in the samples,
so test_messages/test_ux46 never saw them. Now:
"Peak guard: grid charge limited, at this rate 5 814 W, over 5 413 W" /
"Piekbewaking: laden beperkt, aan dit tempo 5 814 W, boven 5 413 W",
"...idle, at this rate ..., over ..." / "...in rust, aan dit tempo ...",
NL Home "Laadt minder van het net om onder 5,4 kW te blijven." and
"Zou minder van het net laden om onder 5,4 kW te blijven."
The rows and the line are added to the samples. The under row is unchanged.
- CHANGELOG known issues and the DECISIONS note: at N=1 the maintenance
charge is not sized to the room, so SAFETY-99 still applies to it.
- DOCS: the peak guard row's new words.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A meter reading late near a quarter's end left seconds the projection did
not count (SAFETY-99), and charge_headroom_w() read them as room: the cheap
run (and price trading, and the N=2 maintenance charge) went back to full
power in the quarter's last seconds and the quarter could land over a banked
month peak or the cap. peakguard.charge_room_w() counts those seconds at the
held reading for the charge only; the guard's floor is unchanged.
The guard row said "idle, heading for 5 814 W, under this month's 5 413 W
peak". Over the limit at the current rate the row and the month-peak line
now say so, and that the grid charge is cut back.
Version 0.19.2, CHANGELOG, DECISIONS. test_safety125.py new; the lag pins
in test_price_run_fixes.py and test_opt20.py and the AST pin in
test_arbitrage.py follow the change (see the pull request).
Co-Authored-By: Claude <noreply@anthropic.com>
Losing the solar forecast mid-run used to widen the gap at once and stop a
grid charge (and a sensor that went unavailable for a minute stopped and
restarted it). A run under way when the forecast is lost now keeps the gap it
was planned with until it ends (Controller.weather_held(), recorded by
_wx_track() each cycle a forecast is read); the wider gap applies from the next
run. The plan key holds the hold state so the plan rebuilds when it ends. Home's
mirror (homeview.trade_verdict) asks the same weather_held(now).
Tests: test_tariff24_weather.py part 4 (going: the charge continues to the run's
end, the next run is not_worth; flap of one and two reads: no stop, no restart;
Home agrees) and a test_modes_p4.py scenario that runs a forecast day at a gap
between 1x and 1.5x the cycle cost. DECISIONS wording follows.
Co-Authored-By: Claude <noreply@anthropic.com>
With a forecast read the gap needed is the cycle cost (0.20), not 1.5 x (0.30),
so a midday 0.21 gap now plans a grid top-up that four scenarios (sunny, Cheap
hours partly, forecast too high, refusal) are not about. They ask for cost 0.30
with the forecast; the no-forecast leg keeps 0.20 (= 0.30 widened).
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, the price gap a mode needs was always widened x1.5 by
Uncertainty.NO_WEATHER, even with a solar forecast read, so a 0.08 day/night
gap never traded at the shipped cycle cost. The doubt is now added only when
no usable forecast is read (solar_fc is None, the day plan's own test), in the
run plan (_price_runs), the charge gate (_mode_roles) and Home's mirror
(homeview.trade_verdict). The rule is one helper, arbitrage.weather_uncertainty();
the modes-off trade path (main.py cycle) keeps its literal NO_WEATHER.
DOCS "Battery modes" sentence, CHANGELOG 0.19.1 line and the DECISIONS note
follow. Tests: test_tariff24_weather.py.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, a day/night or fixed static_profile, no price feed and
arbitrage off, tariff_refresh_wanted() was false: no tariff task, no
tariff_plan, mode_runs None, so Leftover solar / Cheap hours never charged from
the grid and the Batteries screen said "No prices". packmode.enabled(opts) is
now a third term of the gate. With price_provider off the task is pure
arithmetic on static_profile, so no HTTPS call is added.
Also: version 0.19.1, CHANGELOG entry, DECISIONS note, test_tariff24.py, and a
shorter tariff_refresh_wanted() docstring (history stays in DECISIONS).
Co-Authored-By: Claude <noreply@anthropic.com>
daycurve._floor_cut() set a cut from a battery already at the floor (its
cap 0 is below its rating), so a give run with one battery empty and the
other held to its rating was cut until MAX_FLOOR_CUTS ran out: 2,800 cuts
and 460 ms a build, and give blocks back at the hour edge after that.
The shortfall in a step is now shared as control shares it (by what each
battery holds above the floor, packshare.weights(), each at most its
rating, the rest passed on), in the step and in the cut. A battery giving
v kW that holds h kWh is empty at h / v; one at the floor holds nothing and
never sets a cut. The cut lands where the step then comes out exact, so it
is placed once. curve(stats=) reports the floor cuts and whether the bound
stopped one.
test_ux54.py: _floor_cut() checked to the second against floor times worked
out by hand (one battery, a group with one held to its rating, the second
group, the split by what they hold), a battery at the floor sets no cut,
the bound is reported; own_walk() with the reviewer's two cases (30/80 %,
guard, 7 kW house; 2 x 3 kW, 3.5 kW house) and, per build, the floor cuts,
the level points and the time.
No decision, command, timing or option key changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
daycurve.curve() puts a point where a giving battery reaches the floor
inside a step (_floor_cut(), as it already does for a grid charge reaching
its level), so _stops() ends a give block in the quarter control stops. A
walk where control moves the packs with its own model (not the curve's
levels) matches the tab quarter by quarter in 11 cases; 25/45 % with the
peak guard: control 17:00-20:15, block 17:00-20:06.
SolarToday keys an hour by its start taken back from the UTC instant, so
the two 02:00 hours of the autumn change stay apart. test_ux54_dst.py builds
the tab (forecast_payload()) at every quarter of 27-29 March and
30 October-1 November 2027, modes on and off, in the no-tzdata zone and,
where the host has tzdata, ZoneInfo, every call under a time limit raised
as a BaseException that forecast_payload() cannot swallow.
give_later: "No block shows while a battery has no energy to give." /
"Er verschijnt geen blok zolang een batterij niets kan leveren."
DECISIONS: what the walks prove, the modes-off charge drawn on a sunny day,
the clock-change days.
No decision, command, timing or option key changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Reviewed head d2820e8 (Opus review; CI run 1408 checks / unit and 1409 infra-pin green on d2820e8).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
dayplan._hour_slices() added an hour to the local wall clock and read it
back. Without tzdata (tariff._EUTimezone) 02:00 on the spring change reads
as 00:00 UTC again, so the loop never advanced and the list grew until the
process died. Each step now adds the time left in the local hour to the UTC
instant. Ordinary days give the old slices; the spring day gives 23 slices
and the autumn day 25. No option, no text change.
test_safety123.py: every quarter of 27-29 March and 30 Oct-1 Nov 2027 (and
the US change days) for the slices, dayplan.plan() and
Controller._mode_roles(), each call under a hard time limit.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Modes off has no curve (no forecast is read, no house profile kept), so
dayview._levels() never ran there and tomorrow's legs were drawn from the
bound. homeview.trade_runs(ahead=f) now reads each leg at f(name, kind,
start), as mode_runs() does: no give while the emptiest battery is at the
floor, each share sized from that level. dayview._counted() gives a give
the level by Home's own count (the level now, plus what the blocks before
it put in, less what they take out); a charge is read from the floor,
because a full battery covers the house before the cheap hour.
The battery line says a give is planned when one is and the battery has
no give block, also with modes off.
test_ux54.py: the modes-on walk no longer relabels a GIVE role at the
floor; it asks control's own discharge envelope (packshare.envelope())
with each pack's cut-out at the floor. The peak-guard 20 % case asserts
the curve is at the floor at the 17:00 give start. A modes-off walk on a
cloudy day (arbitrage.decide() with the cycle's inputs, the packs moved by
what control does and by the house), cases A-D: control charges and gives
in exactly the quarters the tab has a block. trade_runs(ahead=f) unit
check. _stops() ends a give block where the level the tab shows is at the
floor (LEVEL_DP).
No decision, command, timing or option key changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- Tomorrow's grid block is drawn to where control stops charging. A cheap run
is sized for all batteries together; a slower one is still below
`charge_to()` when it ends and control plans the next cheap slots. The tab
asks `modetrade.energy()` and `priceruns.plan()` with the packs at the
curve's level and extends the run, so the curve charges as long.
- Each battery's block ends where it is at its own level (grid) or at the
floor (give). The curve puts a point where a battery reaches its charge
level inside a step.
- `homeview.mode_runs(ahead=f, rp=...)` reads each block at the level the
curve has when it starts, with Home's own filter and MIN_KWH: no give block
at the floor, no grid block at the planned level. Home never passes either.
- `no_tomorrow` names the hour from `solarfc.BELL_FROM_H`, where the curve
stops.
- test_ux54.py part 7 compares control (`_mode_roles()` every 15 minutes) with
the tab with no tolerance, and adds the cloudy / floor case.
No decision, command, timing or option key changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
F1: tomorrow's blocks no longer depend on the battery's level now. Home sizes
a block from the level now (`room()`, `plan_need()` in mode_runs, the leg
sizing in trade_runs) and draws none when there is no room or energy. For a
day that has not started the builders take `ahead=True` (Home never passes
it): a charge is read from the floor, a give from the ceiling. A grid block is
then kept only where `modetrade.chargers()` would charge at the curve's level
when the run starts. The UX-53 gate is unchanged. Today still equals Home; a
give run in the plan with no block (empty battery) has its own sentence
instead of "No charge or give blocks planned".
F2: test_ux54.py part 7 walks the real `_mode_roles()` every 15 minutes
through tomorrow and compares the roles with the tab's blocks (modes on, the
peak gate, part-full batteries), and the control cycle's verdict at 07:00
(modes off).
F3: the curve counts spare solar as trust x max(0, sun - house), stored at
EFF, as `dayplan.plan()` does (10 kWh sun, 2 kWh house, 70 %: 5.32 kWh).
Strings: cycle, no_tomorrow, ahead, no_level, measured; new give_later.
No decision, command, timing or option key changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
A new tab beside Home and Batteries for today and tomorrow: the solar
forecast, the solar measured so far, the house's expected use and each
battery's expected level, with the plan's own charge and give blocks under it.
- Blocks are Home's: today's are the plan's `runs`, tomorrow's come from the
same builders (`homeview.runs_for()`), in the plan lines' words.
- The sun is what solarfc reads; a daily total is spread over the bell and the
tab says so. The house is HouseProfile.estimator(), as the plan reads it.
- The level is new: `daycurve.curve()` gives each battery the role
`modetrade.decide()` gives it and moves it hour by hour inside the plan's
floor and ceiling. It is an estimate and counts on `solar_trust_pct`.
- Built on request (`GET forecast`), no Home Assistant call. Measured solar is
kept per hour in memory from the reading control already takes.
- A part not known yet is a note: modes off, no forecast, learning, no
forecast for tomorrow, a monthly cycle, no level, stopped, shadow.
No decision, command, timing or option key changes. Found, not changed:
`dayplan.plan()` over-counts a state-only forecast (DECISIONS/UX-54).
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Modes on: Controller._mode_roles() files the trade gate it just asked as
mode_gate; while it refuses, Home draws no grid charge and marks no cheap
quarter. Modes off: a charge after the last dear period is asked of the same
gate at its own start (homeview.leg_taken) and dropped when refused there.
Words: "Lowest/Highest price left" (EN, NL); a flat remainder on a dynamic or
day/night site is no longer called a fully fixed product.
No change to control decisions, commands or options.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner chose 0.19.0 (2026-10-26) because PRICE-02 changes trading behaviour.
Version and CHANGELOG heading/first line only; no option changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Bump version to 0.18.3 and add the 0.18.3 CHANGELOG section: DOC-8, UX-45,
SAFETY-119, SAFETY-121, UX-46, PRICE-02. A patch bump: no option added,
removed or renamed, no default changed.
Co-Authored-By: Claude <noreply@anthropic.com>
The production-shaped plan sees tomorrow from 13:00, so most buys are sold
the next day or later. The ledger forgot the open buy at each midnight and
booked 46 of 51 sales as holdings: 5 trips, +1.21 EUR. Carried over, the
same decisions give 51 trips, +13.81 EUR, all clearing the threshold.
Decisions are unchanged and identical on the old and new verdict. No
assertion changed.
DECISIONS: 27.5 -> 42.6 kWh is the refresh-:00, tomorrow-known variant; give
the range of the other three.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- TariffPlan.arbitrage(now=...) is required (keyword-only, no default); so are
homeview.trade_verdict/refusal_key's now. Existing test calls pass one.
- test_arbitrage.py: no module-level decide wrapper. Fixtures that probed a
one-day plan after its extremes now hold two days (as a site does); the
flap day gets a unique cheapest and dearest hour; the replay breaks its
ties without direction. The flap bound is <= 4 and the replay check is
len(_trades) < 365 again. 228 checks pass on the old and the new code.
- test_price02.py part 6: ties (equal quarters, a real 15-minute day,
alternating hourly prices) and the required now.
- Identity pins: the masked digest is only for the older-tree comparison;
this tree's own digests are pinned with nothing hidden.
- DECISIONS: the tie analysis with numbers.
Co-Authored-By: Claude <noreply@anthropic.com>
test_price_run_fixes.py part 5 and test_modes_p3.py part 1 compare the modes-off
replay with digests printed on older trees. The trade sentence now says
"price period", and a sale quotes another "above the cheapest" figure once the
first cheap period is over. ident.trade_digest() hides exactly those two
things; re-measured on e3e4ba6, 7a00f12, 90bc901 and this tree, the digests
are the same, so every command is unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
TariffPlan.arbitrage(now=...) drops the points whose period has ended
(end <= now), so the cheapest and dearest point can still be traded.
decide() (modes off), the modes-on allowed() gate and the Home verdict
all pass their own now. Hourly feeds and the static tariff are unchanged.
The off-peak sentence and the charge/discharge sentences say "price
period". Tests: test_price02.py; test_arbitrage.py rolls its whole-day
plans to start at now; test_modes_p3.py part 1 digests leave the trade
sentence out (commands unchanged on 7a00f12, 90bc901 and this tree).
Co-Authored-By: Claude <noreply@anthropic.com>
Text only. "stroom te opnemen" -> "stroom op te nemen"; Developer Tools is
"Ontwikkelhulpmiddelen" in HA and ui_text; the green stuck-meter row no longer
starts "Vastgelopen meter:"; maintenance banner names the phase in Dutch;
double "dan" in the device note; plainer peak reserve, peak guard, refused
commands and missing-entity wording. Two stale comments now say the banner
and Home bodies follow the page's language.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Rows and banners are built once with their Dutch beside them (messages.Bi)
and status_payload() picks one by the page's language. Settings notes and the
wizard's checks carry a Dutch twin (Note.nl) that /config/validate picks by
the posted language. The peak forecast label drops "(W)" in EN and NL.
Co-Authored-By: Claude <noreply@anthropic.com>
The jittery-meter numbers depend on the draw (review: 4, 4, 5 of 11 at the
quarter edge; up to 4 quiet quarters at 20 s; first warning up to 61 min
later). Above about 40 s per cycle, a short bound can still use up the
budget when the wire changes hands every few cycles. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
TEST-23 F-1: on a 5 s meter a steady overload warned once in 70 min. The
loop was at its bound 4-5 cycles a quarter, all inside SAFETY-119's settle
of 12 cycles (60 s) and under its budget of 8 per 900 s. The simulation
fed the meter a cycle behind the battery reading, so the guard and the
charge chased each other and gave ~20 bound cycles a quarter.
The settle is now 4 cycles and 22 s (HANDBACK_CYCLES, SHORT_SPAN_S), and
the rolling budget one number, 11 per 900 s, at every cycle length. The
cycle length is no longer tracked. Commands unchanged; the re-pinned
digests of test_safety84/87 differ from bee7431 in OUTPUT_CLAMP rows only.
test_safety119 runs the rig's shape (meter in the same cycle) at 1-15 s
and checks a stop keeps the budget (review F2, X3).
Co-Authored-By: Claude <noreply@anthropic.com>
The quarter-edge numbers were measured with one cycle per reading at a
steady interval. With the default 15 s cycle floor, a meter that is
sometimes slower adds cycles on an old reading and the false alarm can
come back (reviewer's runs, 11 seeds). Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
No single rolling budget met both cases in the sweep (8 false-alarmed on
2 s seed 25 and warned in 1 to 3 of 7 quarters at 15 s). The budget is
now 10 cycles up to a 3.5 s cycle, 8 up to 11 s, 6 up to 16 s, 4 beyond,
per rolling 15 minutes; 8 while the cycle length is unknown. A stop or a
gap over two minutes is not a cycle length. The unsourced "owner
accepted N=8" paragraph is removed from DECISIONS. test_safety119 part 4
now runs 2 s seed 25 and shows a fixed budget of 8 warns there; the
never case runs at 2 s and checks every other quarter at 15 s.
Co-Authored-By: Claude <noreply@anthropic.com>
The rolling budget now holds without a monotonic clock (it never refills).
Quarter-edge tests use seeds 1-3 at 2, 5, 10 and 15 s (no hand-picked seeds).
Re-pin comments point at part 6. DECISIONS lists the limits the owner
accepted with N=8 on 2026-10-20.
Co-Authored-By: Claude <noreply@anthropic.com>
At most 8 hidden bound cycles in any 900 s across all hand-backs, replacing
the per-run budget. Chosen from a sweep (N 3 to 10, 1 to 15 s meters, both
cases); DECISIONS has the table. Tests: never case at 5, 10, 15 s, quarter
edge at 2, 10, 15 s, the rolling budget at its boundaries.
Co-Authored-By: Claude <noreply@anthropic.com>
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The delay is 11 cycles, so up to 11 min at a 60 s cycle. A loop that loses
the wire again within 11 cycles is never counted; review measured one such
case (N=2, cheap-window charge, no forecast, house just over the rating).
The over-rating rule applies on cycles the loop decided. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The re-pinned digests differ only in OUTPUT_CLAMP log rows; every command
and claim is the same as without the fix (test_safety119.py part 5).
DECISIONS: the delay at a 5 s meter and the open swap case.
Co-Authored-By: Claude <noreply@anthropic.com>
When the peak guard or a maintenance charge hands the wire back, the loop's
integrator is re-seeded from that owner's command and kicked by a meter that
does not show it yet. It crossed its rail for a cycle or two and raised
goodwe_integrator_bound while the battery gave what it was told.
The loop's integrator bound is not counted until the plant's settle
(SHORT_CYCLES, SHORT_SPAN_S) has passed since the hand-back. An over-rating
always counts; a bound that lasts warns after the settle. No command
changes and no text changes. test_safety119.py; DECISIONS entry.
Co-Authored-By: Claude <noreply@anthropic.com>
With 15-minute prices the chart now has one bar per quarter (92/96/100),
not hour averages; hourly and static tariffs still draw one bar per hour.
Cheap and dear marks come from the kept priceruns result (battery modes
on) or the arbitrage verdict's two points (off), not a thirds split.
A missing quarter is an empty bar. Removes plan.average_tip (EN/NL).
Co-Authored-By: Claude <noreply@anthropic.com>
README and FIELD-GUIDE.md said the PDF was not rebuilt; it was, on
2026-10-17. Its content is still v0.1.0 and outdated. Rewrap the
DOCS.md intro line. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Both digests hash the discovery payloads, which carry the manufacturer.
Values regenerated; nothing else changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Device id (identifiers) is unchanged; only the display text moves.
test_mqtt baseline updated for that one string.
Co-Authored-By: Claude <noreply@anthropic.com>
The add-on is wired to the inverter's RS485 port labelled EMS. Reword
README, DOCS, config description, field guide source and HTML. The HA
manufacturer string is left unchanged: test_mqtt pins it byte for byte.
Co-Authored-By: Claude <noreply@anthropic.com>
Review of PR #199. "Warns once" left out the Home row and the Settings
note, which stay while the fault lasts. "No option change" now points to
the one case that needs a look.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A missing reading (unavailable, unknown, failed read, non-numeric) no longer
clears the fault: no false 'used again' INFO, no repeated WARNING, the status
row stays. Adds pv.has_reading(). DECISIONS wording fixed; tests added.
Co-Authored-By: Claude <noreply@anthropic.com>
peak_forecast_entity is read through pv.watts() by its unit_of_measurement;
the abs(raw) < 50 size rule is gone. No unit or a non-power unit means the
forecast is not used, with one warning per cause. The validator no longer
claims a kW sensor is taken as watts for this entity.
Co-Authored-By: Claude <noreply@anthropic.com>
SAFETY-118 line: the add-on already turns a kW forecast into W
(main.py read_inputs, abs(raw) < 50), so only the settings-page warning is
wrong. Rounding note and rows: the new settings page; UX-44 also changed
one DOCS line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The settings page contract choice read "Dynamic, hourly" / "Dynamisch,
per uur". Belgian day-ahead prices are per 15 minutes since 2025-10-01.
Now "Dynamic, every 15 minutes" / "Dynamisch, per kwartier". One DOCS
line that called dynamic pricing "hourly pricing" now says dynamic.
test_ui_text.py part 7 fails if either label says hourly again.
Co-Authored-By: Claude <noreply@anthropic.com>
ui.fixed_price, ui.day_price, ui.night_price and ui.periods step 0.00001
EUR/kWh (the period editor's price input took a hard-coded 0.01). A short
c-EUR/kWh hint is added to the four field descriptions, EN and NL.
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
OPT-15 and OPT-20 rows: the retry is two inverters only, and OPT-20 no
longer claims no other battery moves. SAFETY-111 added to known issues.
MAINT-19 marked as from code reading. Wording fixes in the SAFETY-112 and
MAINT-11 rows, UX-38 and the price service note.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
config.yaml version 0.17.0 -> 0.18.0 and a closed ## 0.18.0 CHANGELOG
section for OPT-17, SAFETY-112, OPT-15, MAINT-11, PRICE-01 and OPT-20.
No code change.
Co-Authored-By: Claude <noreply@anthropic.com>
Reviewed at ccdb9dc: full suite 78/78, CI run 1289 green, identity equal to bf9019e. Review: PR #191 comment 2185.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.
modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.
Co-Authored-By: Claude <noreply@anthropic.com>
- test_price_secret.py: the fixed-tariff note on the real /config/validate
route, EN and NL, and none for a spaces-only profile (web.py lang wiring).
- test_price_service.py: the start line is INFO, not WARNING; a dismiss that
raises does not stop the cycle.
- test_maint13/test_setup_only/test_watchdog: ignore only the dismiss of the
old card, so a create with that id is still counted.
- DECISIONS rule 7 quotes the settings note as it is; messages.py comment.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
G1: remove the false 'Fixed tariff not used' notification. One INFO line at
start and an info note beside the setting (EN/NL) when price_service has a
non-blank static_profile; the old notification id is dismissed at start.
DOCS, migration step 5 and DECISIONS rule 7 now say what the code does.
S05: whitespace-only static_profile counts as not set.
G2: maintenance_enabled read through MaintConfig.from_options().
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The spaced-token check used a 5-character token, which the new 16-character
rule refuses on its own, so a validator that stopped checking spaces passed
(reviewer mutation R06). It now uses a long token and checks the reason.
Also pin F3 with no maintenance_enabled key: the default (off) holds and no
no-price words show (reviewer mutation S04). Tests only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
F1: every password option is shown as ******** (set) or empty in /config/model
(options, running, ui) and in a stale refusal; the classic page draws it as a
password field; a save or validate that sends ******** or nothing keeps the
stored value. F2: a static_profile beside price_service is said once at start
(notification and log), not refused. F3 (owner, 2026-10-14): the no-price row,
Home line and notification only while maintenance_enabled is on. F4: tests for
the reviewer's R01 and R10. F5: price_service_token must be 16+ characters.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- DOCS: the migration note said markup and taxes do not matter; with the
provider they are added to the wholesale price. Step 4 and 5 now say what
they set and what static_profile does while no source has a price.
- The gap tests run the notification through cycle(), where the check is
called, so a check that is never called goes red.
- test header: the real-transport checks are section 11.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- The notification, status row and Home line name an earlier day in the
language of the text ("13 okt om 21:00"); the Dutch title is "Prijzen
ontbreken", so the body no longer repeats it.
- The token request does not follow redirects: the host is fixed in code.
- A step back up to the saved prices is one INFO line.
- Tests: whole status payload free of the token, a redirect, the 5-decimal
edge of the old average, modes plan equal to generic_dayahead's.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
A new price source, `price_provider: price_service`: the owner's price server,
one fixed HTTPS host, a bearer token (new password option
`price_service_token`), wholesale energy only so markup and taxes are added as
for generic_dayahead.
The chain is server, then energy-charts, then the prices the history store
kept. A step counts only if it has a price for now. Each step down and back up
is one log line. With every source down a site plans from what it saved.
No price for now: one status row, one Home plan line and one notification, in
English and Dutch, cleared when a price returns. With this provider the
maintenance charge gate reads the provider's prices and keeps the Home
Assistant rule: the current 15-minute price is at or below today's average.
The token is hidden on the settings page, refused when missing, and taken out
of any error text. Other providers, `off` and the Home Assistant pair take the
road they always took (scripted-day probe against 0ce7d35: one line differs,
the refusal that lists the known providers). See
DECISIONS/PRICE-01-own-price-server.md.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Reviewer mutations survived the round-2 page checks: Start forced always
disabled (|| true), and the two flags swapped between Start and Stop,
because the checks only looked for each flag somewhere in the file. The
check now pins each flag to its own button. No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Stop cycle is disabled on a battery that is not cycling. Start cycle is
disabled while any battery cycles and on a switched-off battery. Page only;
the add-on still refuses each of these. DECISIONS notes the one-battery case.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Two reviewer mutations survived the suite: the web layer routing only a
truthy unit (an empty unit then started the bare pick), and the page
showing the server's English instead of its own sentence by code. Both
are now checked. The bare maint_start comment that said a per-battery
unit would ship half a surface is replaced by a pointer to
_maint_unit_action(). No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
maint_start and maint_abort take an optional unit. With two or more batteries
each Batteries card has Start cycle and Stop cycle buttons. One slot per site
stays: a start while a battery cycles is refused and names it (no queue). A
battery that is switched off, an unknown unit, and a stop on a battery that is
not cycling are refused with a plain message. A request with no unit is the
old call. The scheduler and the phase machine are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Two survivors of the review's mutations get a check each in
test_price_run_fixes.py (X1: a held export credited negative in the rolled
quarter; X4: the hold extended by a reading already past E). DECISIONS: the
slow-battery quarter (3456 W, same on e3e4ba6) and the replay of a
maintenance phase starting during the hold.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
clears the chargers, a probing refuser included, while a battery drains
(SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
(`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.
Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
until the quarter's first sample, as the old edge tick was not, so a
standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
drain and the day plan against the probe.
Co-Authored-By: Claude <noreply@anthropic.com>
- a 502 or refused read turns waiting on, the next good read off, and a
read timeout never (two mutants survived without this)
- the flag changes no write with live readings, not only with 502 ones
- the page script's amber dot and batteries-tab banner for "waiting"
- DECISIONS: about 5 minutes per start stage, not "at most"
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Supervisor proxy answers 502 to every add-on read, write and websocket
until Core is RUNNING (proxy.py api()/websocket() -> check_api_state()), so
the add-on cannot control while a slow integration holds HA's start, even
with its entities live. Measured on a safety112 repro stack with the
2026.08.0 proxy code: first write 1.0-4.4 s after RUNNING, 238-300 s after
live readings. Not routed around (DECISIONS/SAFETY-112-...).
While the API does not answer, the first status row is red and is the
banner ("Waiting for Home Assistant to finish starting"), Home shows a
"waiting" state in EN/NL instead of "Needs you now", and the log adds a
"still waiting" line every 5 minutes and the wait's length at the end.
A safety stop, a stalled loop or shadow mode keeps its own headline.
Control, writes, heartbeat and the stand-down are unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The new status row's id `solar_forecast` had no Home title, so Home showed
it under the fallback "Inverter connection". Add "Solar forecast" /
"Zonneprognose" to ui_text, and checks for the title, the tomorrow-gap hint
and blank list rows (review mutations R7, R9, R14 now killed).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.
- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
day is summed. Hourly splits are merged when every member has one, else
the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
day's forecast unusable (no partial sum). A caution row names it by
position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.
DECISIONS/OPT-17-several-forecast-entities.md has the rules.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
SAFETY-107 row names the tested base; MAINT-17 says code reading only;
SAFETY-105 figure is from a simulation; SAFETY-97 edge is 175 W; the
maintenance note cites MAINT-14 and MAINT-15; SAFETY-108 "about 15 s".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
HOLD's time check moves into Maintenance._hold(), used by step() and
_no_soc(). A hold that loses its SoC now ends at hold_min, writes
last_completed and logs the same COMPLETE line. The 15 min HOLD line says
the hold still ends at its normal time. Behaviour with a reading is
unchanged (differential trace against db9e231).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- A price-provider site with no fixed tariff is not a gate (its plan never
sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
test_static_tariff forbids main.py reading `static_profile`; a small
static_gated() in static_tariff.py answers it, and the Controller keeps the
answer in `_price_gated` beside `cheap`.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- gate_open is true with no price gate set up, in a cheap window, or while the
pack is taking charge; the stall rule and timeout now work on a no-tariff site.
- reset the save timer on a phase change; exact 5 min gap-cap test.
- test_safety93: original timeout scenario kept (B finished) plus a case where a
due B takes the slot after A's failure.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.
No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The test table gives 1.5 kW at N=2 and 3.9 kW summed at N=3 under a
surplus, and about 1 kW after a lost link without one; not 1.9 kW.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Mutation M13 (a battery out of the split counted in the house point)
survived; a direct check now kills it. win[0] is read through a guard
(test_named_absence).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While a battery settles from its ended drain (SAFETY-95), the house point
was grid + every battery's reading. A register can be 10 s older than the
meter, so B swung 860 -> 1650 -> 870 W on A's old reading (rig check 5).
Now the house point is held and moved only as far as the meter proves:
each battery is between its last changed reading and its commands since
(a reading that changed this cycle, or a refused side, as it reads).
N=1 and 1 s registers are byte-identical to release/1.0.
DECISIONS/SAFETY-103-old-readings-after-a-drain.md, test_safety103.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-103 swing 'by about 800 W for about 5 s'; SAFETY-99 'late, by less
than 30 s'; MAINT-10 row: one-at-a-time is not new; SAFETY-96: drop the
test-only 800 W; SAFETY-90 and MAINT-10 rows trimmed to two sentences.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
F1: test_safety95 checks that a dropped draining battery is this rule's
(stale link, N=3, 4000 W: grid import 676 W vs base 786 W); kills R2.
F2: _charge_track tested directly with a contradicting drain (SAFETY-91's
pin as a floor against a closed pack); kills R3. Today a drain contradicts
only through a refusal; the clause stays, as a contradiction sends 0 W.
F3: a drain ends on a refusal only when the battery will not give
(refused > 0, as _held_back()); one that will not take still drains.
Tested both signs; kills R8.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
test_safety95.py: the N=1 byte-identity now covers all six drain ends
(Off and stale link were missing); end_at()/measure() read through a
default, so test_named_absence.py passes (it failed on bdec66e); a check
that a dropped battery's start is 0 W even under a pinned charge (it
kills a mutation that survived).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
When a battery's drain ended (done, Off, timeout, abort, stale link,
refusal), its drain floor stayed in the site target and landed on the
others: B 0 -> +1600 W in one cycle at a 1200 W house, exporting; under a
solar surplus B gave into the export.
Now, on that cycle, the loop starts from what the others stood at plus the
battery's new command, raised to the house's own point when the house needs
more (never above last cycle's start). While the battery settles, the loop
counts the batteries at its start instead of chasing the drain's tail on
the meter. Then one slew step a cycle. N=1 is unchanged.
test_safety95.py; DECISIONS/SAFETY-95-drain-end.md; one DOCS line.
test_modes.py: opt11 n2_maint re-pinned on purpose (its drain ends by a
refusal at 1655 s; B now stays at the house's 1420 W instead of 2500 W).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
F1: resetting the count on each refused write hid a battery that really
refuses behind a link refusing 1 write in 3 (never learned; learned at
358 s with the count kept). F2: a board at 0 W before its link is stale
learned no refusal untested (mutation R7 survived); now a 1 s-lag case.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a battery out of the split (stale link), with refused writes, or
settling after a step the loop did not make (a charge end, a rejoin) now
counts in the freeze test at its command, not its reading. Its real power
still reaches the loop through the meter. At a drop its share leaves the
loop's start point (the others take over one slew step a cycle); at a
rejoin it enters at its reading. No refusal is learned while a battery's
writes are refused. N=1 and the 46 identity digests are byte-identical.
test_safety78 part 2: the dropped-drain case now rests at B 1510 W (grid at
its -10 W aim) instead of 1500 W; the drop no longer sends B to 2500 W.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
HA can take minutes to start (2026-10-05, 502 from the proxy). Then TZ holds,
which the Supervisor sets from HA's zone, so the hour stays right; only a TZ
of UTC there now logs a WARNING asking for a restart. A test pins the 3 s
budget on the zone request (a mutant without it survived).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
test_maint10.py part 10: at two inverters both packs get the site zone, the
real Controller is identical for 11 UTC and 13 Brussels, and two due packs
across 24/25 Oct 2026 and 27/28 Mar 2027 start at the local hour on
successive days; a pack freed in the repeated hour does not start there.
Part 3 adds 28 Mar 2027. DOCS: an existing install keeps its saved hour, now
read as local time; an hour set to make up for UTC goes back to 19.
DECISIONS: the SAFETY-83 gate is met; section on two inverters.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While the add-on is down the batteries are at 0 W (it sets 0 W when it
stops; the ESP32 watchdog after 30 s), so the import before its first
reading was the house, not the aim. Those seconds now count at
gap_w(limit, the import seen first), and after a restart the restored
reading's held 30 s is topped up the same way. Status row: "counted as
high use". Tests take the pre-start import as the house (batteries at
0 W) and add restarts of 10/60/150 s with a restored averager.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A meter gap past meter_max_age_s left seconds the quarter average never
counted, so the guard was blind for the rest of the quarter (rig case 7b:
3964.8 W against a 3450 W aim). Once readings are back, the missed seconds
now count at the higher of the limit and the import seen just before and
just after the gap with the batteries at 0 W (peakguard.gap_w/fill_gaps);
the gap's first meter_max_age_s is topped up to that too. Seconds before
the add-on's first reading count at the aim, and the page says part of the
period was not measured (EN/NL). The bill record is unchanged; no option.
DECISIONS/SAFETY-90-peak-guard-after-a-gap.md, test_safety90.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from
SAFETY-94/97, no option change). New `## 0.15.0` section with the contents
since 0.14.0 (cf705a9#171, 3129dae#172) and the known issues.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Owner decision 2026-10-04 (review R1). A wrong idle reading more than
about 100 W off hid every refusal on that battery. Clamped under the band,
the band keeps 0 W +-25 W, so a battery reading about 0 W while refusing is
caught whatever was learned or restored. Samples are still taken to 250 W.
Beyond about +-170 W of idle a battery behaves as in 0.14.0.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The N=1 stale-path refusal and SAFETY-42's parked test are centred on the
idle reading; learning stops while control is stopped or the sign watchdog
has latched. Each had no check (review mutants X7, X8, X13, X14).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At a 5 s meter a register frozen at rest on B trips the stale gate before
the 12-cycle evidence; its refusal must be centred on B's idle reading,
or the site stops and re-trips instead of refusing B.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
B's power reading shows -95 to -118 W at idle (standby draw), so the
|reading| < 100 W refusal band never held a refusing B: never at N=2,
and since SAFETY-94's shared rule not at N=1 either (review F1).
Each unit now learns its idle reading (app/idle.py): only while control
runs, the unit is not refused/stale/tripped and its command has stayed
within 50 W for 120 s; first value a 120 s mean, then a 30 min follow;
samples beyond 250 W dropped, value clamped to 250 W; saved per unit and
restored. The shared refusal evidence, compute()'s N=1 engage and end,
the unit refusal ends, the stale-path refusal and SAFETY-42's "parked"
test are centred on it. Until learned it is 0 W, the rule as it was.
Refusing B caught at N=1 28/28/65 s and N=2 24/24/60 s (1/2/5 s
meters), before never; refusing A unchanged. Healthy B with its offset,
SAFETY-94's scenarios, 96 runs: 0 stale, 0 refused. Live replay: 0.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
- test_safety94 part 4: time under 250 W is not counted; a command that
swaps direction every cycle is never refusal evidence; a reading moving
away from the ask does not restart the evidence. These kill review
mutants R1, R3 and R6, which survived the PR's tests.
- DECISIONS: at N=1 a battery with B's standby offset no longer latches
a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after
35/d s of wall time.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The stale-reading gate counted its 35 s from the register's last change, so
after a rest the first read after a new command tripped it (SAFETY-58; live
2026-10-03, four trips 1 s after the command). It now counts only the time
the command asked the register to move.
At N=1 the refusal engaged after 12 frozen cycles if the reading was under
100 W at that moment, which a battery reversing through its lag passes at a
1 s meter. The refusal now needs the N>1 evidence at every roster size: under
100 W, one way, for 12 cycles spanning 22 s, restarting when the reading
moves 50 W towards the ask.
DECISIONS/SAFETY-94-lagging-battery.md; test_safety94.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Slew step not one house's 400 W; three two-inverter known issues, not
four; commissioning reference covers a new install; SoC example holds
for decimal sensors; SAFETY-95 states the jump, not the export.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Two inverters are now supported for maintenance and the peak guard
(SAFETY-91, SAFETY-93). No option changes.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A battery still in CHARGE but dropped by the allocator (stale link, or a
SAFETY-73 refusal contradicting its charge) left its -2000 W in the loop's
start point, and B went 0 -> -1600 W in one cycle. The end is now noted
after the unit claims are filed: in CHARGE, live and not contradicted.
Tests: part 6 (stale link, refusal) and a spy on the guard suspension.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2, when a battery's maintenance charge ended, its watts stayed in the
loop's start point and landed on the other battery (B 0 -> -1600 W in one
cycle, charging from the grid at a 6000 W house). On the cycle a charge
ends, the loop now starts from what the others stood at plus that
battery's new command. N=1 and all identity digests unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A SoC reading flipping across the reserve swapped ~1000 W between the
batteries on each flip (grid +-500 W with unequal lags). Also grades
next_quarter()'s staleness boundary (29.5 / 30.5 s).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a battery at or under its own peak reserve now weighs 0 whenever
the site gives (not only for the peak), a draining battery's pin becomes
a floor at its drain rate so it rises before the held one gives, and a
quarter's edge is graded on the next quarter when its first telegram is
late. SAFETY-25 option A stays: the held battery is still drawn once the
others are full. N=1 unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Crash, not stop, for SAFETY-61; Watchdog off by default; its own
warning for the 50 W peak margin (also under a higher month peak);
"refuses power" for SAFETY-52/73; no one-house options claim.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Bump config.yaml version 0.12.0 -> 0.13.0 and close a ## 0.13.0
CHANGELOG section covering every merge since 0.12.0 (a45ed06), with the
known issues SAFETY-90/91/92/93/94. Option surface 77 -> 83, none removed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Rule 2 graded each battery against last cycle's command and graded charges
too. On plantsim's battery (10 s lag) at the 2 s meter it warned at every
drain or charge start and 15 times an hour under the peak guard at N=2; a
charge tapering near full warned 11 times in 50 min (SAFETY-42 section 7).
Now a discharge is graded against the least it stood at over SHORT_CYCLES /
SHORT_SPAN_S. DOCS lists `mode-bound` under Loop reason. test_safety85 part 7:
peak guard with a dead battery, lagging plant, taper; part 3: the bound ends
with maintenance.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The loop's integrator bound counts only on a cycle the loop decided. A battery
another owner set (maintenance, the peak guard, a safety limit) alarms only
when it gives more than saturation_w less than told for saturation_cycles
cycles. At N>=2 the loop is bounded while maintenance holds a battery, so it
does not wind and control comes back one slew step a cycle. The status row
counts episodes, not cycles. Digests re-pinned where behaviour changed on
purpose; DECISIONS/SAFETY-85-no-false-not-keeping-up.md has the list.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
A draining battery that may still give is raised from its drain rate
towards its rating for the peak floor while another battery is held
(peak > drain); before, the floor's rest landed on the held battery. In a
HOLD, a held battery's own pin counts among the others: a held drain no
longer over-places the site, and a held charge probe no longer parks it.
Tests: test_safety87.py part 10 (drain beside a held battery, N=3 HOLD,
unknown cut-out and unread level at N=3, a stopping row outranks the
running peak alarm). DECISIONS entry updated, incl. the modes-on exception.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
At N>=2 a battery at or under its own peak reserve is held: it gives
nothing for the peak (weight 0 while the site gives) and the guard's need
is placed on the live, non-refusing batteries above theirs. The guard is
floor-limited, and alarms, only when those cannot hold the limit at full
power for ALARM_HOLD_S. The peak alarms no longer read "Not ready" or hold
the Home page at 0 W, because control keeps running. N=1 is byte-identical.
DECISIONS/SAFETY-87-guard-uses-able-batteries.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
At N>=2 the holding pack's pin follows the guard's floor while the loop
still asks for +5000 W, so the ALLOCATOR "could not be placed" row was
re-logged on every 1 W change and filled the 40-row action log. While the
pin is raised, cycle() now files a site `hold` ceiling at the floor
(P_MAINTENANCE), as SAFETY-84 does for a charge. Filed only when the
holding pack gives; hi == the floor, so it never clashes with it.
Tests: a noisy N=2 house logs no ALLOCATOR row and at most one clamp
row (20 and 20 without the ceiling); the ceiling is the floor itself;
a CHARGE is not refiled at N=1. The DECISIONS entry records the owner's
2026-10-01 decision: the HOLD ends on its clock, no top-up.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
During a HOLD the holding battery gives what keeps the quarter at the peak
aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain
(SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the
other live batteries may place, so they give first. A site stop still
decides alone. The hold ends on its clock even if the level dipped.
Below the aim nothing changes (rows identical).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Part 3 read the simulated September's peak with the wall clock, so from
2026-10-01 it read no peak and crashed on every tree (4ad8298 too).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A 6500 W house needs more than B alone: A must give (the N>=2 suspension),
with a non-vacuous run without it (banks over the cap, 'Load too high').
Without P1 the charge is not sized, as at N=1: A charges at 2000 W.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N>=2 a cheap-window maintenance charge files a site `hi` (`charge`,
P_MAINT_SHAPE) equal to what the charging pack's own `hi` places, so the
other pack never has to give against it. The charge is sized to the
quarter's headroom under the peak aim so it yields to the peak guard, and
to 0 W under a site safety stop. N=1 byte-identical (safety84_identity).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
test_safety83 part 1: under a month peak banked above the limit the drain
is lifted to peak - margin, and a drain the guard raises (steady or with
5 s spikes that saturate it) gives no 'Load too high' alarm; the part 3
overload still does.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Kills M5 (refiled at P_SAFETY) on its own sentence, not only through the
per-cycle claim check.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The start hour was compared with the UTC hour, so the shipped 10 started at
12:00 in a Belgian summer. It is now read in Home Assistant's time zone
(fallback: the container's TZ, then UTC, one log line says which), and the
default moves to 19. DST: a missing hour starts at the first hour after the
jump; a repeated hour starts only in its first pass. Stored options are not
rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A floor exactly at the drain rate stays at P_PEAK (kills `lo >= rate`), and
part 4's N=2 check no longer shares its failure list with N=1.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A second unmeasured-headroom stop in a quarter latches the charge: a
headroom missing every other cycle flipped it 1799 times in 30 min.
- Unit test of the run-edge hold's end conditions and of a small step.
- Outside its probe a refuser does not make the others rest (M15 red).
- DECISIONS: one review line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- DECISIONS: the Cheap hours change and why; the no-sun replay (the gain is
Leftover solar buying the evening's shortfall; the forecast added 0.14
EUR); the reconstruction bias stated plainly.
- DOCS: Cheap hours ignores the forecast; a reading from before midnight
is stale.
- The forecast line: "Solar still to come today: ..." (it is what is
left, and it stays within the 12-word limit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Cheap hours only fills to the ceiling with or without a forecast, as the
design (section 1) says. Skipping the sun's share cost 0.31 EUR on real
2026 prices (29.72 against P3's 29.41) and saved nothing on the P3 set.
- A forecast reading from before local midnight is stale: until the
integration refreshes, "left today" is still yesterday's 0 and
"tomorrow" is really today.
- Forecast entity ids must be sensor.[a-z0-9_]+ (they go into the
/api/states/<id> path).
- House profile: a stored day that is not a date, or is after today, is
dropped instead of kept forever.
- Text: the forecast line says "for the rest of today"; the learning line
no longer promises "tomorrow" (a plan needs one full day).
- Tests for four surviving review mutants (hour sample floor, the dear run
after the cheap run, share by room, daytime use) and the fixes above.
- Replay tool: `--fc zero` (a forecast of no sun).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- homeview: no "This one does not charge" while the draining battery waits
(no floor then, so the other battery may charge from solar).
- test_safety78: one wait line across a probe, a second episode logs again,
the card while waiting, and a seeded sweep of the floor against every
other claim (part 6).
- DECISIONS: the wait case, and the measured N=1 peak and N=2 charge
follow-ups.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with 5a4cdc2
digests; control still byte-identical. Unit checks for export and the
hold across a missing reading. test_peakguard's saturated fixture moves
the hold start back instead of waiting it out.
- DECISIONS and DOCS updated: costs of the hold, tolerance reasoning, the
double count in control left to a follow-up.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
F1: with battery modes on, the peak guard projects the quarter `now` is in
even before its first P1 sample (PeakTracker.project(roll=True)), and only
a measured stop latches the period. The edge tick no longer reads "no
seconds left", so a charge is not stopped and latched at a quarter edge.
F2: after a run edge the loop is held at E until the meter shows the step
(EDGE_HOLD_S, longer while the battery still moves). The replay gained a
lag model (dead time, reading age, P1 debounce, 1 s cycles) that shows
TEST-23's overshoot without the hold.
F3: a charge refuser's SAFETY-73 probe inside a cheap run is a charger
pinned at PROBE_W, the others rest, so the probe actually runs.
Modes off stays byte-identical to 5a4cdc2 (new late-P1 identity scenarios).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The alarm now also needs peakguard.load_too_high(): with the battery at
full power, the quarter still ends more than 10 W over the real limit.
The battery reading is the lower of this cycle's and the last, so a meter
sample from before the battery's last increase is not counted twice.
At most one alarm per quarter. Control outputs unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At two inverters the drain pins its pack and the site target is split
around the pin. Below the pin the other pack had to charge, the allocator
refused the opposite directions, and the site sat at 0 W with an ARBITER
line every cycle (house below or above the drain rate, or a grid charge).
main.py now files a site limit `drain` (lo = what the pin places, at
P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds
power in the same direction. A drain that cannot give power waits with
one log line. With battery modes on, no grid charge while a pack drains,
and the other battery's card says why. N=1 is byte-identical.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).
Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Step 5 said "Choosing a mode for each battery comes in a later update",
stale since P1. It now points to battery modes on the Batteries screen
(EN/NL); test_setup checks the new line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Owner decision 2026-09-29. Selling is off until it can be judged on the price
the grid pays: packmode.SELLING_ENABLED = False makes read() answer
sell=False whatever the store holds, pack_sell is refused ("Selling is off
for now."), and the page has no selling switch; the sell code stays. Until
the P4 forecast, only Cheap hours only charges from the grid
(packmode.GRID_CHARGE_MODES); Leftover solar holds and gives in the
expensive runs. Help, Today and plan lines, DOCS and DECISIONS follow.
Replay, 16 days: Solar first + Leftover solar 19.44 EUR net (P2 19.33).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A sale block on the plan no longer says "Worth up to" at the import
price: a sale earns the lower injection price.
- The selling switch help (EN/NL) and DOCS say the grid pays less than
power costs; DECISIONS records why P3 loses on the replay.
- test_modes_p3 part 11: modes on ignore the site trade switch (R13), a
battery in maintenance takes no part (R10), a headroom stop latches for
the period (R8). All three mutants survived before and are red now.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Cheap and expensive hours as runs of consecutive firm price slots
(priceruns.py); each battery's role per tick from its mode (modetrade.py):
grid charging for Leftover solar / Cheap hours only, never Solar first;
holding for the expensive runs; selling per battery (pack_sell) above the
spread and the floor. The site trade is sized inside the modes (loop bound)
and the peak guard's headroom; a run edge reseeds the loop. Cheap hours only
and selling are enabled on the Batteries screen and in the HA select
(appended). The site Why row no longer says "held back" when the peak limit
pushes power up (F2). Modes off: byte-identical to 7a00f12 on the trade path.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- quarter_target_w() is now the margin under quarter_ceiling_w(): a peak
banked between cap - margin and the cap was aimed at exactly, so one
overshoot crossed the cap; above the cap the same overshoot raised the bill.
- safety79_identity.py hashes charge_headroom_w() and the shaping suspension,
and adds n1_maint/n2_maint (cheap window, forecast across cap - 50 .. cap).
Digests re-printed on ed739d4 and pinned; margin 0 still identical.
- test_margin_under_banked_peak; DECISIONS and DOCS updated.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- A refusal past the log-once set or the 32 cap is counted in the log at
1, 10, 100 and so on, so a repeated attack stays visible.
- The logged topic is printable only (no forged log lines).
- mode_announcement(): the start-up store logic, now tested with a real
Store. A removed config topic stays stored, so a start with no broker
cannot forget it (rename case tested).
- A test ties each HA mode option to the page's English name.
- packmode.enabled() is tested for "true", 1 and "false".
- Retained-command text, DOCS and DECISIONS updated to match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The peak limit's Why and plan block need a real power request (floor above
0 W), not a blind or floor-limited guard. An Off battery gets the peak
block only while it gives power. Why no longer says every battery gives.
- test_batteries_screen pins the fixture clock: unpinned it failed every
morning. New checks cover the trade and cycle filters, the blind guard and
an Off battery that A covers alone.
- Settings keeps only a picked view; a link to Installer is not remembered.
- Browser check: badges, unsaved change across views, locked value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to ed739d4.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.
peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
- Batteries: one card per battery with On/Off, the mode list (cheap hours
and selling greyed out until OPT-11 P3), level, and Now / Today / Why
lines built in homeview.py. Replaces the OPT-11 P1 minimal cards and uses
the existing pack_use / pack_mode actions and store keys.
- An Off battery the peak limit still needs says so with its figure; no line
shows 0 W beside moving power (OPT-11 P1 test F2). Today says "Not planned
yet" until OPT-11 P3/P4.
- Home's plan leaves Off batteries out, except for the peak limit.
- Settings opens on Simple: the layout's simple fields with an applies chip
and a note, plus the battery switches and modes. Installer is one tap.
- English and Dutch words in app/ui_text; test_batteries_screen.py; browser
check tools/ux13_browser_check.py (CHECK=1 ux13_screenshots.sh); new and
changed screenshots only.
No control, allocator, arbiter or command module changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
Reviewed: a mode gives way to the peak floor only as far as it needs; SAFETY-03 kept at the rail.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- arbiter: a mode now gives way only as far as a site limit above P_MODE
needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
released only when the peak floor bound S, so a trade won above the floor
kept them and placed less than the floor (an Off battery at N=1 went to 0 W
under a 2000 W floor), and a capped grid charge released an Off battery.
While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
(peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
loop bound counts live units only). DOCS and DECISIONS say the new rule.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.
compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).
Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- test_ui_text.py: key parity, placeholder parity, English-left-in-Dutch,
semicolon, 25-word description and 2-sentence line each now fail on a
spoiled input (the English-left check was not a real mutation).
- Jargon lists now cover the whole 'Not' column of STYLE.md section 4, in
English, with the Dutch equivalents.
- nl.json: 'gewijzigd worden' where 'wijzigen' read as intransitive,
'Bezig met bewaren' for the saving state, 'Metingen kloppen niet'.
- test_uimodel.py: an overlap that changes partners is named piece by piece
(a surviving mutant of _tiling's partner check).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/ui_text/nl.json and app/uitext.py: every page word in Dutch, English
fallback per key; the page picks by browser language. Home's sentences
move into ui_text `home_words`, so /status?lang=nl builds them in Dutch.
- test_ui_text.py: EN/NL key and placeholder parity, STYLE limits, jargon
lists for both languages, no inline details, untranslated Dutch caught.
Shared rules moved unchanged to tools/style_rules.py.
- tools/ux13_screenshots.sh/.py: DOCS screenshots from the demo fixtures in
headless Chromium; docs/img/ux13/. Battery modes (P3): no screenshot.
- "Other time windows": a list editor (ui.periods) that builds
static_profile and names bad times, empty prices, overlaps and gaps.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.
Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
R1: first_start also needs a Store created at this boot (Store.fresh), so
old never-started sites (both TEST-23 add-ons, one in shadow) stay on Home.
R2: a kettle skip after a fall says on the last step that the reading went down.
R3: the shadow switch goes only on the model the wizard posts, never into V.
R4: Home Assistant not answering is red on the last step.
R5: meter + solar + battery below -300 W flags a reversed battery sensor.
R6: the live checks say what to change and where.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.
- First run: /config/model says `setup_needed` when the stored options name
no power request entity, or on a new install (no `setup_done` and no
`auto` in the Store, control not started). The page opens #setup only
when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
change decides: up keeps meter_invert off, down turns it on; a net or
import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
each power request entity exists in HA (bad if not, SAFETY-77), battery
levels and power with direction, solar sign, prices. Saves with
shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
1. Discard reloads /config/model: after a stale save the page kept the
new fingerprint with the old values, so Discard + Save overwrote the
other surface's change without a 409.
2. Removing cards back to one restores the stored inverter shape, so a
flat site stays flat after add + remove.
3. A choice the page can only keep ("Other time windows") stays offered
while it is the stored value.
4. A load locks every locked value again.
5. at_zero() needs an accepted 0 W write; before the first one Home says
"Going to 0 W" (the heartbeat writes every heartbeat_s, so it clears).
6. A field with a unit drops the translation's "(W)" from its label: the
peak limit read "Peak limit (W)" beside a kW value.
7. A mirrored choice lists the mirrored field's keys, so a search for
static_profile finds the contract on a fixed-price site.
8. test_settings: a save refused by ui_to_options writes nothing.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Settings tab: the Installer view (app/static/settings.js), drawn from
app/uilayout.py through the new app/uipage.py: search, six collapsible
groups with "n to fix / n to check / n changed" badges and an "applies
after a restart" chip, radio cards, segmented choices, sliders with units
(the peak limit in kW), entity pickers with search and the live reading,
inverter cards, solar rows, locked measured values behind "Change", and
the add-on's refusals, warnings and info beside the field they name.
- Save path: the page posts its model to the existing config/validate and
config/save; uimodel turns it into options before the shipped validator,
so nothing it refuses is saved. No route added. A value equal to the
stored one is written as stored, so a save that changed nothing writes an
identical blob. Save bar, then the restart dialog that names 0 W.
- The region choice shows its preset year; Wallonia and Brussels are listed
as having no preset yet (TARIFF-22). "Classic settings" keeps /config.
- P1 test findings: (a) "Going to 0 W" until the last accepted power request
is 0 W; (b) the trade blocks and the price line name the feed's own points
("Lowest published price"), the hour bars say "hour average"; (c) the entity
list's WARNING gives a reason on a timeout.
- test_settings.py; test_home, test_haentities, test_uilayout extended.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) *
LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both
units 10-16 times an hour after load steps (site held 0 W). 2 s and slower
ticks are unchanged.
- REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that
stops taking charge is always above its cut-out level.
- test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal;
the release/1.0 checks are restored and a span check added.
- test_refusal_units: lagged-reading and full-battery plants, two new checks,
U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Trade blocks: none on a battery with no room, no sale at a negative price
or while the emptiest battery is at arbitrage's floor, nothing when a
level is unknown. A give after a charge may use what the charge put in.
- The refusal line names the real reason: prices not published vs gap.
- The plan's peak line uses the guard's ceiling (this month's peak once
above the cap), as the peak card does.
- House below zero: 0 W inside the idle band, no figure beyond it.
- Price bars are "Low price" / "High price": the add-on trades in one hour.
- Control toggle: one request in flight at a time.
- test_home: the new cases; the house-sign mutation now goes red.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- app/static/{index.html,app.css,app.js}: tabs (Home, Batteries, Settings,
Setup), hash routes, phone bottom tabs, light/dark. Served inlined at "/";
the route list is unchanged, and every URL is relative.
- app/homeview.py: /status gains state, now, batteries, plan, attention,
month_peak and control beside the old fields. The plan is what the add-on
does today: the arbitrage verdict (the same plan.arbitrage() call as the
cycle), the monthly cycle, the peak limit, "follows the house".
- The Home plan chart has hover, tap and keyboard-focus tooltips: price bar =
hour and price; block = what, when, why, kWh and EUR.
- Region preset and year: in config/model (for P2) and on the Home price line.
- test_home.py; test_messages part 8 scans every Home sentence; STYLE plan line.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.
test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- uimodel: editing a listed inverter keeps the stored flat keys, and a
region of "own" keeps a stored price_taxes_profile (both were dropped).
- haentities: a failed read also waits CACHE_S, so polls while Home
Assistant is down do not queue one 10 s read each.
- ui_text: the Flanders preset names its DSO, and the help says
Wallonia and Brussels have no figures yet. REGION_PRESETS cites the card.
- tests: decode of a reversed solar row, both kept keys, the backoff.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The foundation for the new settings page. No visible UI change.
- app/uilayout.py: screen -> group -> part -> field for every option in
config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
scale, step, entity kind, show conditions, Simple/wizard placement and
"applies after a restart". Ranges stay in the schema, words in
translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
inverter vs the list, solar rows, static_profile from simple prices, a
year-stamped region preset for the levies figure, and an OPT-11 hook for
arbitrage_enabled that changes nothing yet). Unchanged derivations write
the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
a note when a list is passed; config_notes() adds checks that need live
data (missing entity, a kW sensor read as W, a limit below this month's
peak). /config/validate returns them as "notes". No refusal changed: 261
recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
the TEST-23 option files and config.yaml defaults), test_haentities, a
warning-tier part in test_validate; test_messages scans notes and
ui_text; test_pv and test_selfconfig part 7 widened on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
own 100 W answer, not below saturation_w: a battery derated to 100-499 W
was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
DECISIONS record carries the traced cause of the replay's extra trips.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Since UX-10 the waiting sentence counts its seconds when it is read, so the
second read could cross a second boundary on a loaded runner ("1 second" in
the row, "2 seconds" in the check). CI run 953 on this PR failed that way;
test_price.py passes locally on the same tree.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).
test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- After a restart, each restored stop (direction per inverter and site,
delivery, circulation) also writes its saved reason to the action log.
log_level defaults to info and events starts empty, so the DEBUG
evidence alone left the figures only in state.json.
- A flapping meter (ha_signed under a flat load, 42-97 s between changes)
logs at most one WARNING/INFO pair per 10 minutes, with the episodes in
between at DEBUG.
- LONG_LINE_OK refuses any key whose text is a safety reason.
- test_watchdog keeps the byte pin beside the meaning pin, since the text
did not change.
- DOCS says the DEBUG line needs log_level debug.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30
seconds': the age is 30.4 s, which rounds to the limit. The limit alone is
always true at the moment the line is logged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
- Every WARNING/ERROR line that reported a safety reason (direction, delivery,
stuck meter, stale reading, peak guard, circulation, over-rating) now ends in
the reason's code (messages.reason_code()). The reason itself, figures and
limits included, is on a DEBUG line right after it and in the action log.
- The reasons and state.json are unchanged, so an old state file loads and
shows the same way: every saved reason opens with its code.
- test_messages part 6 checks every WARNING+ line at 25 words as logged; nine
non-safety families are listed with a reason and capped. The byte pin in
test_watchdog now pins the meaning, in order.
- The meter logs one WARNING per quiet episode, and INFO when back, so the red
row's "the add-on log shows why" holds. The Why line past the hold names
the missing reading. Action log: "25 engagements", "Shadow mode off: ...".
No trigger, latch, threshold, log level, notification id, cadence, row colour
or banner order changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
master is what the Home Assistant Supervisor clones, and the Supervisor
compares config.yaml version strings - so 0.11.0 could not be offered to an
installed 0.10.1 without this bump reaching master.
Carries SAFETY-56 (#112), TEL-11 (#113), the CI-9 follow-up (#102) and SEC-2's
docs/RELEASE.md (#108), by way of the 0.11.0 cut (#114).
NOT A FAST-FORWARD. master was not an ancestor of release/1.0: 0f14c2a, the
pre-SEC-2 direct push, exists only on master. Its tree is the same object as
the merge base b0b24e5 (c1fef26), so it carries no content delta, and
`git merge-tree --write-tree` over the two branches returns a tree bit-identical
to cccb2fa's own (6670502). This merge commit therefore contributes exactly
release/1.0's tree - master synthesises nothing.
Reviewed as the release decision, not a re-review of content. Verified from the
remote: slug goodwe_controller and every identity key unchanged (cross-checked
against the live box's Supervisor export), version 0.10.1 -> 0.11.0, and the
green is this PR's own - run 828 / job 1953, path checks.yml@refs/pull/115/head,
PRNUM 115, GRADED refs/pull/115/head merged into master, run_attempt 1, 31 test
files all passing in 8m01s of real work.
predeploy_check.py re-run against the owner's current options (exported
2026-09-24 20:02, 75 keys, pv_entity unset): CLEARED, exit 0. That retires the
stale-2026-09-07-export warning in the pull request body. Option surface
75 -> 76 with only pv_entity added, str? defaulting to "", no key removed, no
default moved, no rule added to validate.py - no SystemExit(78) on this hop.
Merging is not installing. No tag is cut here and `ha store reload` /
`ha addons update` have not been run.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
master is what Home Assistant clones. SAFETY-57 fixed a deadlock that parked
the reference install's battery for ~13 minutes while the site exported
2.4 kW, and the Supervisor compares config.yaml version strings - so the fix
could not reach an installed 0.10.0 without this bump reaching master.
Brings SAFETY-57 (#104) and the 0.10.1 cut (#105). master was a strict
ancestor; no conflict was possible.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:54:29 +02:00
331 changed files with 96052 additions and 9509 deletions
timeout-minutes:70# ~4 to run; the rest is queueing for the single slot
timeout-minutes:40# ~21 to run, measured (CI-18: 10 files at a time; was ~27 at 6, ~60 serial, 22-37 on a busy host); the rest is margin for a busy host
env:
# ⚠️ UNDER /home/homelab, NOT $GITHUB_WORKSPACE (ENV-01, and re-measured
# during CI-01). act's workspace is `/root/.cache/act/<id>/hostexecutor`, a
@@ -534,6 +534,20 @@ jobs:
# shorter timeout - a 60 s limit was tried during CI-01 and reported
# exactly the false hang the docstring predicts.
#
# ⚠️ CI-15: THE FILES RUN SEVERAL AT A TIME (TEN SINCE CI-18, SIX BEFORE),
# NOT ONE AFTER ANOTHER. The serial
# loop summed 3 557 s on SAFETY-125's run (job 2580) and ran past the
# runner's 60-minute cap. The loop now lives in .gitea/ci/run-tests.sh (it
# comes from the merged tree, like the Dockerfile), so the same script runs
# locally and here. It runs the longest files first, then the files whose
# assertions depend on the wall clock - test_loop.py and test_freeze.py
# (TEST-30 / CI-06) and test_safety87.py (CI-15) - ALONE, after the
# parallel batch, so no sibling can steal their CPU. The reasons are in
# the script. Its output stays one
# PASS/FAIL block per file, in a file per file (never one shared /tmp/out).
# A file that is not in the script's two typed lists still runs, in the
# parallel batch: the list is a sort order, not a selection.
#
# test_freeze.py part 3 runs against the real `sim/hwsim.py` from the
# checkout above; GOODWE_REQUIRE_HWSIM=1 makes it fail rather than use its
# stub (CI-12). Lines a test prints with a `CI: ` prefix are echoed on PASS.
@@ -552,28 +566,7 @@ jobs:
- name:the add-on's own tests
run:|
set -eu
docker run --rm -e PYTHONDONTWRITEBYTECODE=1 -e GOODWE_REQUIRE_HWSIM=1 -v "$WS:/w:ro" goodwe-addon-checks:1 sh -eu -c '
cd /w/goodwe-addon/goodwe_controller
set -- test_*.py
if [ "$1" = "test_*.py" ]; then
echo "NO test_*.py FOUND - the mount is empty or the layout moved. NOTHING has been checked."
exit 1
fi
echo "$# test file(s) to run"
rc=0
for f in "$@"; do
start=$(date +%s)
if python3 "$f" > /tmp/out 2>&1; then
echo "PASS $f ($(( $(date +%s) - start ))s)"
grep "^CI: " /tmp/out || true
else
echo "FAIL $f ($(( $(date +%s) - start ))s)"
tail -40 /tmp/out
rc=1
fi
done
exit $rc
'
docker run --rm -e PYTHONDONTWRITEBYTECODE=1 -e GOODWE_REQUIRE_HWSIM=1 -v "$WS:/w:ro" goodwe-addon-checks:1 sh -eu /w/goodwe-addon/.gitea/ci/run-tests.sh
# GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds
net grid exchange at zero by emulating the inverter's smart meter over RS485,
and runs the monthly battery maintenance cycle the vendor box was doing.
net grid exchange at zero by sending the inverter a grid reading over its RS485
EMS port, and runs the monthly battery maintenance cycle the vendor box was doing.
```
repository.yaml add-on repository metadata
@@ -30,7 +30,7 @@ goodwe_controller/ the add-on
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4; outdated)
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4; rebuilt 2026-10-17, content still v0.1.0 and outdated)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
docs/RELEASE.md how a change reaches the battery - `master` is
@@ -107,10 +107,22 @@ on real hardware, and the comments in `control.py` say which.
### CI and the infra pin
CI (`.gitea/workflows/checks.yml`) runs every `test_*.py`, with `admin/goodwe` checked out next to this repo at the commit in `.gitea/infra-pin`, so `test_freeze.py` grades against the real `sim/hwsim.py`. If that checkout fails, the job fails. The local stub is used only in local runs, and it prints `STUB USED` when it is.
CI (`.gitea/workflows/checks.yml`) runs every `test_*.py` (ten at a time, the wall-clock ones alone afterwards: `.gitea/ci/run-tests.sh`), with `admin/goodwe` checked out next to this repo at the commit in `.gitea/infra-pin`, so `test_freeze.py` grades against the real `sim/hwsim.py`. If that checkout fails, the job fails. The local stub is used only in local runs, and it prints `STUB USED` when it is.
The pin tracks `admin/goodwe`**release/1.0**, not master. Two non-required checks go red when release/1.0 has moved past the pin: `infra-pin / fresh` here, on any add-on PR or push to release/1.0, and `addon-pin / fresh` in `admin/goodwe`, on every push to its release/1.0. Nothing re-runs `addon-pin` after a bump, so it stays red on that admin/goodwe commit; `infra-pin / fresh` green on the bump is the all-clear.
**Bump the pin** whenever either is red. Set `.gitea/infra-pin` to the new release/1.0 SHA (`git ls-remote <gitea>/admin/goodwe.git refs/heads/release/1.0`) in a PR, and let `checks / unit` grade the tests against it. CI reads `admin/goodwe` with the Actions secret `INFRA_READ_TOKEN`.
### Running only the affected tests (dev and review rounds)
`checks / unit` runs every `test_*.py` and stays the only merge gate. For a local round, `sh .gitea/ci/run-affected.sh` runs just the files your diff reaches, in the same `goodwe-addon-checks:1` image and through the same `run-tests.sh`:
```bash
INFRA_DIR=~/path/to/admin-goodwe-at-the-pin sh .gitea/ci/run-affected.sh # release/1.0 .. working tree
sh .gitea/ci/run-affected.sh --base origin/release/1.0 --head my-branch # a committed range, with my-branch checked out (the tests run from the working tree)
python3 .gitea/ci/affected_tests.py --files goodwe_controller/app/price.py # only list, with the reasons
```
It prints each chosen file and why, then `SELECT n of N`. A test file is chosen if it imports a changed file, directly or through other modules, or names it in a string (a tool launched by path); a changed test file is chosen; and so is a fixed safety set (`SAFETY_SET` in `affected_tests.py`, one reason each). Anything it cannot map (a non-Python file such as `config.yaml`, a deletion, a `.py` no test reaches) prints `SELECT ALL`. Most modules are imported by `app/main.py`, so a change to `app/` usually selects nearly everything; the saving is for test-only, tool and helper changes. A partial run ends with `PARTIAL RUN ... NOT the merge gate`. `INFRA_DIR` is the `admin/goodwe` checkout at `.gitea/infra-pin`, which `test_freeze.py` needs.
## Compatibility
**Check the serial number, not the model name.** Characters 6-8 of the serial are
@@ -118,17 +130,17 @@ the platform tag:
| tag | platform | verdict |
|---|---|---|
| `ESU EMU ESA BPS BPU EMJ IJL` | 105 — ES/EM/BP, AA55-era meter bus | **supported** |
@@ -7,7 +7,8 @@ This applies to everything a home owner or installer reads: notifications, phone
- **Body**: **one sentence** of at most 25 words, saying what happened and what to do. A **red alarm** may use up to **3 sentences** (70 words, each sentence at most 30 words), so that no action a person must take is lost.
- **Details**: the last line links to the add-on documentation and names the section with the rest: `Details: add-on documentation, section "<title>" under Notifications.` Background, figures, reason codes and history go there or into the log, never into the body.
- **Status row**: one sentence of at most 15 words. A **red** row may use up to 3 sentences (30 words), like a red alarm. It shows the live numbers the reader acts on and never an HA entity id. **Banner**: at most 12 words. **Refusal**: at most 30 words, naming the setting by its label and then its key, as `messages.setting()` writes it: “Inverter rating” (max_w), or “Inverter rating” for inverter-b (inverters.max_w) for one inverter in the list. **Option name**: at most 6 words, not counting the group prefix. **Option description**: at most 30 words. Where a value comes from belongs in DOCS.md.
- **Log line** (WARNING/ERROR): one line, at most 25 words, with the numbers that matter. The reasoning goes on a DEBUG line. Log lines stay in English and are not translated. A reason text a line quotes (`%s`) keeps its reason code (`OUTPUT_CLAMP`, `STALE_READING`), because that is the evidence an installer searches for. The reason itself has the shape of a red alarm: at most 3 sentences of at most 30 words. The line as logged has no semicolon, banned word, capitals, "1 times" or "(s)". `test_messages.py` part 6 builds every such reason with the real code and checks it. A line that repeats every cycle is DEBUG. INFO lines carry no section numbers, ISO timestamps or capitals.
- **Plan line** (UX-13 Home screen: the plan, tooltips, a battery's "now" line): at most 2 sentences, each at most 12 words. Words in `app/ui_text/<lang>.json` under `home_words`, built by `app/homeview.py`, checked by `test_messages.py` part 8. The page's own words, English and Dutch, are checked by `test_ui_text.py`.
- **Log line** (WARNING/ERROR): one line of at most 25 words **as logged**, with any built text filled in. Log lines stay in English and are not translated. A line that reports a safety reason gives one plain sentence and the reason's code (`STALE_READING`, `OUTPUT_CLAMP`), the evidence an installer searches for. The reason itself, with its figures and limits, goes on a DEBUG line right after it and into the action log, never onto the WARNING/ERROR line. It keeps the shape of a red alarm: at most 3 sentences of at most 30 words. The line as logged has no semicolon, banned word, capitals, "1 times" or "(s)". `test_messages.py` part 6 builds every such text with the real code and checks it, and lists the few non-safety families still over 25 words. A line that repeats every cycle is DEBUG. INFO lines carry no section numbers, ISO timestamps or capitals.
- **Refusal length is counted as shown**: a setting placeholder counts as its label and key, and the long cases are driven through the validator (`test_messages.py` part 3).
- **Event line** under the buttons: the plain words of `messages.hint()`, like a green row. The add-on's own action log stays technical and is not shown on the page. Installers read it as `events` in the `status` JSON.
- **Sentences**: one idea each, active voice, present tense, with nothing nested in brackets and no semicolons (a semicolon is a second sentence in disguise). These translate well into Dutch and French.
**Status: SHIPPED.** Written down by MAINT-20 part 2 from the long comments and
docstrings of `app/main.py`, so the module can keep one line and a pointer. The
comments that were shortened but not rewritten here are kept word for word in
[[MAIN-orchestration-archive]], by their line in `app/main.py` at release/1.0
`d4c01da`. Since MAINT-21 the Controller's methods are split by job into
`app/main.py` and `app/ctl_*.py`; a comment keeps its text and moves with its code. Related: [[SAFETY-07-peak-guard]], [[FCST-04-the-day-that-is-carried]],
- **Per-write budget (DEV-02).** Each write is dispatched concurrently and bounded, so one hung `hass.call()` cannot eat a sibling's layer-1 budget (the ESP32 zeroes after about 30 s, and a fault on A could zero a healthy B). The number is derived: `heartbeat_s` max 25 s, layer-1 veto `validate.FIRMWARE_INGEST_VETO_S` 30 s, so 25 + 4 < 30. test_inverter.py grades the inequality, so raising the heartbeat ceiling goes red instead of taking an inverter to zero. Below hass.py's 10 s HTTP timeout on purpose: abandon the write and re-issue it next tick, since `last_write` moves only on an accepted write.
- **Tariff refresh (OPT-04).**`resolve_tariff()` may do an HTTPS fetch. The tick feeds the ESP32 heartbeat, so a supplier's TLS timeout on the tick would push the add-on into layer 1. The tick never awaits a fetch. The 30 min cadence is not about price change (day-ahead publishes once at 14-16 h CET and 8.3's carried hours go firm then); it picks the switch up within the hour at 48 fetches a day. The age bound answers another question: a failed refresh still stores a plan (the 11.4 static fallback), the bound covers the refresh task dying while a plan from hours ago stands as current. Three missed refreshes, for `p1.max_age_s`'s reason.
- **Status rows (TARIFF-11).** The Tariff row used to be `static_status()`'s sentence alone and never saw the provider plan (read 'no static profile' at all 802 samples of a 40 h soak with a live feed). `tick_words` and `plan` are two clocks and the row says so; the plan is stamped with its own age from `tariff_at` (TARIFF-12 does not move it on a kept plan), and `age_s` is the caller's measurement. The Arbitrage row used to be `"off (arbitrage_enabled)" if self.arb is None`, under a comment saying `arb is None` iff trading was off; false, since `cycle()` returns at the input hold before `self.arb = None`: `arbitrage_enabled: true` plus a sensor answering None rendered 'off (arbitrage_enabled)', naming an option that is on, and past the first cycle the previous decision stood as current. Three states: off, armed with no decision this cycle, a decision with its age (always printed: a row that reports staleness only once stale cannot be told from one that never does).
- **`stop` is required (review catch).** `stop=None` made a Controller that cannot stop itself the default: on the late-refusal path in `run_control()` it logged the banner, returned and left the process alive forever with no loop and no output.
- **Action log first.** The store migration can log to it (15: how an operator finds a latch was re-armed); an AttributeError on the way to saying so would stop the add-on booting.
- **Roster and migrations (DEV-02, SAFETY-44, MAINT-05).** Every per-device value lives on the roster objects (app/inverter.py); a `Tuning` and an integrator are deliberately not per device (6.2: one integrator on P1 above the split; a second regulating the same meter is the two-writers failure). The SAFETY-02 key migration runs before the first `Inverter` reads its latch, else a tripped install comes up armed with a green banner. SAFETY-44: it is handed `roster_names(opts)[0]`, never `UNIT_A` (on a declared roster the flat latch landed under `unit/inverter-a/`, read back under the name it was handed, stamping the marker); `roster_names()` returns `[UNIT_A]` on the flat shape so today's path is byte-identical. `misdirected` is unreachable from that call site (`unit` is a roster member by construction; dropping the `roster` argument survives 28/28), so the claim that the call site buys the refusal is gone; the argument stays for new callers and is graded in test_maintenance.py. The maintenance migration targets `self.inverters[0].name`, not `UNIT_A`: with `UNIT_A` the history would sit under a name on no roster (a nameless entry falls back to a positional `inverter-1`). Every two-pack fixture once named its first entry `inverter-a`, so swapping them left 19 files green; `migrate_maint_keys()` now grades the namespace it wrote against the names the machines read, and test_maintenance.py sections 9 and 11 use `["garage", "shed"]`.
- **CFG-04 disclosure.** A declared `inverters:` roster ignores `soc_entity`, `batt_entity`, `batt_invert` and `max_w`, which the UI still shows. Rule 9(e) refuses the dangerous one (a flat `setpoint_entity`); the rest cannot be refused (the schema has no blank value) so one action-log line at every start names the roster and the ignored keys.
- **Site bound.** Summed from the roster, not `opts["max_w"]`: it is the integrator bound and rail of the site loop, then split. Identical at N=1; a per-unit `max_w` binds each share through its `supervised` claim.
- **SAFETY-39 slew fallback** is 0 ("follow the rail"); it was 1000, a stale third copy. `control.slew_limit_w()` is the one reader.
- **CFG-03 in main.py.** Eight `opts.get(key, <literal>)` calls used to live in the maintenance setup and two disagreed with config.yaml (2500 against 2000). `MaintConfig.from_options()` reads them. A ninth key goes in config.yaml `options:`/`schema:` and `maintenance.MAINT_OPTION_DEFAULTS` only.
- **Watchdog thresholds (SAFETY-30).** The per-unit pair is re-derived at two inverters, not carried (it grades a command against one unit's own power). The site pair is used only at N>=2: the 300 W threshold carries (meter noise, deadband), the window does not (110 s at one inverter, 215 s at two, against a 180 s hold).
- **Latches (SAFETY-02, -31, -34, -42, -18).** SAFETY-02: one per actuator, restored from namespaced keys; graded on every start (a latch that failed to move namespace, or was taken by an older add-on in a rollback, is a disarmed guard, so a disagreement re-arms by hand and shouts). SAFETY-31: site-level, flat keys (circulating power is defined over the roster), restored because it acts. SAFETY-42's delivery latch does not act, so it is restored only so the ALARM survives (the 2026-09-02 outage went unseen 6 h 25 m with the detector correct). SAFETY-18 is not restored (does not act). SAFETY-30's site check is armed only at N>=2.
- **PV (TEL-11).** Instrumentation only; wiring it in would be an unrequested behaviour change and would destroy the measurement.
- **Peak guard setup (SAFETY-07, TARIFF-01, FCST-04).** See SAFETY-07-peak-guard.md and FCST-04. The windowing caveat for FCST-04: hours already elapsed leave the spread, so a cheap night that has gone no longer sets the day's cheapest hour.
## Cycle state and latch repair
- **Allocation record (SAFETY-28).** The tick that mints a record increments once per resolution, not per loop iteration. A cycle with no resolution (the "inputs missing, not yet stale" hold) must not bump it: that hold returns before the allocator so one missed poll does not zero the inverter, and the heartbeat re-affirms `self.target` through the write path; bumping would make that heartbeat unauthorised and drop the site to 0 W. The record is superseded, never expired.
- **`self.arb` (TARIFF-11).** See "Status rows" above; `arb_at < cycle_at` is the derived "the latest cycle did not reach the arbitrage step".
- **Shadow (SAFETY-10, SAFETY-47).**`shadow_would_w` is what a live controller would have put on the wire; `self.target` is what is standing on the wire (held at `shadow.WIRE_W`, re-seeded each shadow cycle). Folding them shows an operator a number nothing is doing. The "sized from the billed-quarter meter" flag is recorded where the decision was taken (the page runs on its own task); False, not None, before the first shadow cycle.
- **ARB-03.**`units` is a property derived from the roster so a site cannot claim two actuators while holding one writer. At N=1 (6.2) the grid connection and the only inverter are one actuator; a second entry makes per-inverter claims stop being site claims (ALLOC-01).
- **DEV-02 latch guard (`_check_sign_latch...`).** Runs on every start: gating on `rep.ran` swallowed store.py's rule-2 round trip (upgrade, downgrade with a trip in the window, upgrade; the controller came up untripped while state.json said `sign_tripped: true`; a firmware rollback path was performed on this site on 2026-09-02). The gate could go because `handle_action()` clears the flat keys with the namespaced ones and the trip mirrors them. SAFETY-44 second half: the question is whether a namespaced latch THAT A MACHINE READS is set. An earlier version accepted any `unit/*/sign_tripped`, which blinded the guard on exactly the installs the broken migration had put the latch under `unit/inverter-a/` (a key nothing reads). The first blunt fix (every off-roster latch is litter) re-armed a healthy A off B's mirrored flat key (test_inverter.py DEV-02 restart case). `UNIT_A` is the discriminator: the only name the broken migration wrote. A single flag written for two intents was defeated by one removed unit's key (roster ['garage','shed'] with `unit/old-shed/sign_tripped` drove on a state file reading `sign_tripped: true`; `tools/rehearse_roster.py` exit 1); the fixtures now hold both arrangements. Residual: a first unit really named `inverter-a`, latched and removed from the roster is re-armed on `inverters[0]` (conservative). The printed reason is the flat mirror's (whatever tripped last), so on a multi-unit site one inverter's evidence may appear under another's name; test_maintenance.py's check that the reason is not the removed unit's depends on that fixture's flat string, not on this code.
- **Maintenance views (MAINT-05).**`maints` is one FSM per roster entry; `maint`, `maint_unit` and the button target are views of the one that holds the slot (`maintenance.arbitrate()` allows at most one out of IDLE). validate.py rule 6 grades `maintenance_charge_w` against the weakest cap on the roster.
- **N=1 views.** Properties, not fields, and they refuse at N>=2 (6.2's identity is false there). Nothing inside main.py may read them (test_inverter.py AST scan).
- **`_arm_sign_watchdogs` (SAFETY-30).** Called every cycle because fixtures append an `Inverter` after construction; a detector frozen at construction would be graded against the meter at a roster of two. `arm()` touches no timer or latch.
- **Per-inverter refusal (SAFETY-73).** The probe ask is PROBE_W, not `saturation_w`: a unit's share is often small (a 400 W night load split two ways) and SAFETY-43 would name the empty battery as not delivering. The site target is restarted from the watts on the wire when a unit reopens (phase A: -1059 W).
## Write path and cycle
- **The write gate (SAFETY-28).** specs 1.5 makes two writers on one actuator a non-goal. `len(validate.ACTUATOR_WRITE_KEYS) == 1` is a fact about the options schema, not the writes, and goes false when CFG-04 adds per-inverter config. So the enforcement is on the write: a number reaches the wire only if the single allocator placed it, on this tick, for this unit (`Allocation.authorises()`); a second writer must file a Claim. 0 W is always authorised and the test for zero comes first and reads nothing: the failsafe branches write 0 W while the allocator has refused (`Allocation.ok` False, no shares), and a gate asking its permission would deadlock the failsafe behind the component it answers; at S = 0 broadcast and allocation coincide, so there is no over-command (the hazard is N-times loop gain from broadcast, TEST-19's `N=2 gain 1.0` limit cycle). The predicate is `value == 0.0`, not a `failsafe=True` flag, which a second writer would pass; -0.0 == 0.0 and a nan never gets here. DEV-02: the unit is an argument, not the N=1 view; the default refuses at N>=2. The refusal sits above the clamp and below the non-finite coercion.
- **Clamp (SAFETY-03)** is on the only path to the wire, so no optimizer, maintenance or manual path routes around it. A non-finite value is loss of input (11.1), coerced to 0 W. Every engagement goes to the action log undeduplicated; the notification is deduplicated.
- **Shadow (SAFETY-10)** suppresses in the same method, below the gate and the clamp, as a substitution not a return. It is not a second writer.
- **Reads (DEV-02, TEL-12).** Each inverter's readings are gathered concurrently across units and sequentially within one; PV entities ride in the same gather (a slow sensor must not push a healthy battery toward layer 1's veto). P1 has no inverter-side fallback: the inverter's AC power correlates 0.998 with battery power and 0.09 with the real meter.
- **Stale reading (SAFETY-37/56/57).** The power reading goes through the freshness gate, the SoC does not (the power feeds the sign and delivery checks, which a frozen register fools). SAFETY-57 rewrote the escape clause: "it clears itself when the register reports a different value" was false for the state announced, because the 0 W it announces is what stops the value changing. The release is reported, never silent (it withdraws a SITE STOP).
- **TARIFF-03.** The one shiftable load is the maintenance cycle's cheap-window top-up; the static window is synchronous and I/O-free, and validate.py refuses `static_profile` together with the price entities.
- **Cycle ordering (SAFETY-02/31/42).** The watchdog evaluations run every cycle, before the input hold, so a run of held cycles cannot leave their timers resuming from a start that predates the gap. Reason first, flag second (each `set` writes the file): a crash between persists a reason nothing reads, not a latch with no explanation. The per-unit trip mirrors the legacy flat keys (store.py rule 2 covered only the latch present at migration time). The site check is flat-keyed, armed only at N>=2. SAFETY-31's input is MEASURED power (`inv.batt`), never the allocation record, which has sign-coherence by construction.
- **Maintenance FSMs (MAINT-05).** Each pack is ticked with its own SoC (a minimum would abort a cycle on a sibling's state, an average would declare a pack full that is not); `arbitrate()` runs first. A deferral is carried to the status page because the edge-logged line scrolls out of the 40-row log.
- **Aggregates.** SUM for the site bound, achievable rating and the battery power the site loop regulates against (`compute()`'s saturation test compares against the site target; one unit's power trips the freeze permanently, up to 510 W of split-dependence at gain 0.2, test_alloc.py part 8). MINIMUM for the discharge permission (the emptiest pack). MEASURED power for circulating power. Unknown bounds stay unknown when any unit is silent.
- **Trade sizing (OPT-09).**`trade_sizing` uses arbitrage's own SoC bounds, not the BMS cut-out (SAFETY-25): sizing is the trade's business, the pack envelope is the pack's. Weights are a preference, so a pack between its arbitrage floor and its cut-out can still take part of a sell; fixing it needs a per-pack envelope depending on which claim won the tick.
# MAINT-28 - during a real peak the maintenance charge stays paused
**Status: fix-forward after the rig FAIL (TEST-23, f3f9483).** Tests: `test_maint28.py`, `test_maint28b.py`. No option added; the peak aim, the month peak and the MAINT-13 numbers are unchanged. MAINT-24 follow-up (rig test finding F-1, `reports/MAINT-24-test-report.md`).
## What happened (rig x10, house 6.5 kW, month aim 5.95 kW, A in maintenance CHARGE)
`peakguard.shaping_suspended()` pauses the charge while the forecast is over the aim or the guard is engaged. MAINT-24 moved the aim from 3450 W to the month aim (SAFETY-80), so the pause no longer lasts the whole peak: the guard gives, its projection drops under 5950 W and it idles ("heading for 5 6xx W, under this month's peak"), the pause ends, the floor charges A 150-460 W, the grid goes to 6.3-6.9 kW, the guard trips again. A flipped charge/give 468 times in 45 min (base 02eac3b 11). The quarters stayed at the aim; the cost was a battery working against itself and a grid that swung 5.4-6.9 kW.
## The change
`peakguard.shaping_held(suspended, held, forecast, aim, house)`: `suspended` is the old `shaping_suspended()`, and once it was true the pause stays until the house (`grid + battery power`, the load without our own charge) is `MAINT_RESUME_UNDER_W` = 300 W under the aim. A guard that is engaged or a forecast over the aim still pauses at once. House unread: the forecast stands in; neither read: no pause (SAFETY-63). `ctl_cycle.py` keeps the flag in `_maint_peak_hold`. The hold is for N=2 and up, and only where MAINT-24 moved the aim (a banked month peak above `peak_cap_w`, so the aim is above cap minus margin). Elsewhere the old rule stays, byte for byte: SAFETY-87's N=1 digests (`n1_charge_low`) and SAFETY-119's N=2 charge at 5050 W over a 5000 W cap with no banked peak are pinned, and 1b5f7c9 behaves as 02eac3b there (a chase that was not a MAINT-24 regression).
Why the house and not the forecast: while A gives, the forecast sits just under the aim by design, so no forecast margin is both safe and reachable. The house is the meter reading plus the batteries' power (`grid + site_batt_w`): the net demand the meter would see with no battery at work. Solar is already in it, and that is right: the aim is a limit on what the meter takes, so a sunny hour that lowers the net demand is real room, and a cloud that raises it brings the hold back at once. It is not the gross load, and it would be wrong to add PV back (that would hold the pause on room the meter really has). It does not stay put when a battery steps: see "Fix-forward" below.
Why 300 W: the house wanders +-50 W; once the charge resumes it settles at (aim - house) / 2, so 300 W gives at least 150 W, three times the noise, and charging less than that is not worth a restart.
The flag lives only while the charge-only branch is taken: every cycle that reaches the maintenance loop starts it at False, so a maintenance that ended, a mode change or a missing aim cannot carry a stale True into the next charge (test_maint28.py part 1b). `cycle()` has two returns before that loop, and the flag is kept through them on purpose: "inputs missing" and "readings late" (SAFETY-128) are holds of under `stale_after` seconds that write nothing and decide nothing, so the next full cycle sees the same charge and the same peak. A missed poll must not end a peak pause; a reset there would restart the charge on it (`_maint_shape_suspended` is kept through them the same way).
It only ever keeps the maintenance charge off. No cut-back is delayed or weakened: the guard's claim is filed as before. While the pause is held, the pack in CHARGE gives only its share of the guard's floor (0 W if the guard holds it at its reserve), and the batteries together give only what the guard needs (see Fix-forward, F-2 and H-1). The first version let A give for the house; it was dropped.
## Numbers (sim, real `cycle()`, A rated 2500 W)
House 3000 -> 6500 W for 45 min -> 3000 W, +-50 W every 5 s, banked month peak 6000 W (aim 5950 W), forecast = quarter average so far plus the rest at the present grid (`scratch/MAINT-28/dev/m28_repro.py`; `test_maint28.py` runs the same shape for 15 min to keep the suite short).
| 45 min load | base 02eac3b | 1b5f7c9 | MAINT-28 (f3f9483, without the lag) |
|---|---|---|---|
| A charge/give reversals | 0 | 52 | 1 (the first trip) |
| A charging seconds in the load (of 2700) | 0 | 367 | 301 (before the first trip) |
| A out / in (kWh) | 0.65 / 0 | 0.45 / 0.51 | 1.67 / 0.56 |
| charge back after the load | - | 3 s | 3 s |
Rig (MAINT-24 test report, F-1): 468 reversals in 45 min on 1b5f7c9, 11 on 02eac3b. Live shape (house 3000 W): no pause, A 1475 W, as MAINT-24.
## Tests and mutants
`test_maint28.py`: part 1 the real peak, 1b the stale hold, 2 `shaping_held()` edges, 3 the unchanged cases (digests equal 1b5f7c9). On 1b5f7c9 itself (hold stubbed out) part 1 and 1b fail. Mutants, each red: M1 hold state not kept (`held` always False: the 1b5f7c9 behaviour); M2 resume line `-` to `+`; M3 house not passed; M4 the per-cycle reset removed; M5 the N=1 gate removed (digest `n1_peak`: N=1, banked peak, house 6500 W); M6 the aim gate removed (digest `n2_nobank`).
## Not changed
MAINT-24's rate and its tests, N=1, the drain, modes off (digests of 1b5f7c9). The pause for a late or missing forecast.
The sim had no battery-reading lag, and the first version said the 300 W line is far larger than the lag moves the estimate. That was wrong. The rig publishes a battery's power every 10 s; the meter is newer. After each guard step charge -> give (+500-1000 W) the next meter reading shows the give and the battery reading still shows the charge, so `grid + site_batt_w` drops by the step, under the 5650 W line: 69/69, 132/133, 215/215, 51/51 releases at a median 5430 W with the house at 6450 W or more. Test: `test_maint28b.py`, sim `Lag.batt_period_s`.
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 4 s after the load (12 s in test_maint28b), not 0: the first settled estimate. No cut-back is touched.
**F-2 and the cap.** Owner 2026-11-13 ("1" = cap): while the pause holds, the pack in maintenance CHARGE gives only what the guard claims for the peak, at any SoC; other packs unchanged (replaced by H-1 below). Owner 2026-11-13 ("ok max", relayed by the manager): accepted "while the hold is on, the pack in maintenance CHARGE gives at most the largest floor the peak guard claimed in the current quarter" (about 0.37 kWh per 45-min peak in the sim; quarters at or under the aim).
**H-1 (review 2026-11-14, owner decision 2026-11-14): the batteries together give only what the guard needs.** With the cap on A alone, the loop gave for the whole house with B (Cheap hours): in the live-try shape (A 11 % in CHARGE, B 25 %, house 6.5 kW for 90 min) B gave 4.6 kW, went from 25 to 10 % in 43 min, and two quarters were 6502 and 6499 W against the month peak 6000 W. So while the pause holds, `_m28_share()` also files one site limit (source `charge`, `P_MAINT_SHAPE`, per-site `_m28_site`): `hi` = the largest floor of the period, never under this cycle's floor. The guard's claim is not cut: `hi` is at least the floor, `P_PEAK` outranks `P_MAINT_SHAPE`, and `_peak_on_able` still places the whole floor. Outside the hold nothing is filed. Live try, same shape (test_maint28b): quarters 5357 to 5911 W (aim 5950), B 0.86 kWh and ends at 20.6 % (1b5f7c9: 1.0 kWh, 19.8 %), B switches give/idle once, A never. The re-pinned `n2_charge_banked` quarters are 3349 and 3950 W (aim 3950).
The rule as built (`Controller._m28_share()`): while the pause holds (N>=2, month aim above the cap) the pack gets a unit limit `hi` = the largest part of the guard's floor placed on it in this 15-minute period. Its part in a cycle is the floor less what the other units are placed at in this cycle's split without that limit, so a part the guard's split puts on the other pack is not this pack's. A pack the guard holds at its reserve (`peak_guard.held`) gets 0 W and its part starts again from 0 W. The largest part is kept per unit (`_m28_hi`, keyed by the unit) and dropped in a new period or when the pause ends; only one pack can be in maintenance CHARGE anyway (`maintenance.arbitrate()`, one slot per site).
Why the largest of the period and not the present part: the guard alone lands the quarter 9.5-10 W over its aim in the sim (SAFETY-126: its own projection ends on 5950.0 W but the meter reading it counts lags the true grid), and with the present part only, test_maint28 part 1 ends at 5960.1 W; the largest of the period lets the loop keep A up and it ends at 5925 W. Why not `hi` = 0 W: with the other pack under its reserve the guard needs this one (test_maint28b, house 12 kW, B at 18 %: A gives 1.07 kWh for the guard).
Tests (test_maint28b, 13-min load, A 5 kW): A at 49 %: SoC drop 0.64 point (the owner's 0.37 kWh per 45 min is 0.70 point here; the check is <= 0.70). Both packs able, B on Cheap hours: B is placed nothing, A's limit is the period's largest floor (3087 W) and A gives 3081 W. B on Solar first (it gives for the house): A's limit stays under the period's largest floor by 500 W or more in 740 of 744 paused cycles, and the quarters stay under the aim.
Sim, rig shape, 45 min, house 6500 W (load from minute 10), A in CHARGE at 49 %, B 30 % on Cheap hours: A gives 0.17 kWh (f3f9483 0.44), SoC 50.5 -> 49.0 %, charge/give flips 1, give/idle switches 1, quarters 5358 5897 5911 5176 4477 W, charge back 4 s after the load; B gives 0.23 kWh (before H-1 3.04, f3f9483 0.32). test_safety84 n2_charge_banked: banked quarters 3349 and 3950 W against the aim 3950 W.
Mutants, each red: the freshness check dropped (always settled); the cap dropped; the other units' placement dropped (part = the whole floor); one cap for the site instead of per unit; the 0 W for a held pack dropped (all in `test_maint28b.py`); the period's largest dropped (present part only: `test_maint28.py` part 1 quarter 5960 W); `_batts_settled()` replaced by True at the hold in ctl_cycle.py (the 45-min rig shape in `test_maint28b.py`, one stale release); the site limit dropped (the live try in `test_maint28b.py`: quarters 6502 and 6499 W, B 2.91 kWh to 10.0 %).
# OPT-23 and OPT-28 - the day plan counts the sun right, and the night charge covers the expensive-hour shortfall
**Status: for review.** Tests: `test_opt23_28.py`.
`dayplan.plan()` now buys, for Leftover solar batteries, what the house uses in the expensive hours less the sun counted for each hour, shared by capacity, and reads a state-only forecast from now for every span (OPT-23).
- **Shortfall.**`sum_h max(0, house_h - trust x sun_h)` over every expensive hour, `/ EFF`, from the floor. It replaces the use over the run with no sun counted, which on a day and night tariff bought for the whole day (G1, `reports/UX-69-design-report.md`). The sun before the run is unchanged. A run with its dear hours after sunset gives the old number.
- **House use.** An hour with sun is read at no less than the night base, as the sun sum reads it (the profile is net of the sun). An hour without is read as measured. An hour with no forecast counts no sun.
- **Several batteries.** One total, shared by capacity with the ceiling passed on (`dayplan._spread()`). With the same floor and ceiling for all, they reach the ceiling together, so a shortfall that one battery cannot hold fills both to the same level, not one first. More than all hold: all go to the ceiling, `Plan.uncovered_kwh` is the rest, carried by the grid (OPT-36 counts the other batteries first), as the screen says.
- **Cheap hours** still fills up; **Solar first** still never charges from the grid. The mode help says so.
- **OPT-36 (0.20.1):** Cheap hours and Solar first batteries give first; Leftover solar shares only the rest of the shortfall (`dayplan._cheap_give_kwh()`, `_solar_first_give_kwh()`). A Cheap hours battery counts the level its charge reaches: the cheap run, then later slots still worth charging in and no dearer than any slot from the expensive hours on, under the peak aim, x EFF stored. A Solar first battery counts what is left after the house's use until the hours start, each hour at no less than the night base. Live, 2026-11-02: A at 60 % went to 95 % while B at 94 % covered the hours. Owner, 2026-11-02: Solar first counts too. Test: `test_opt36.py`.
- **Not done:** the run length (OPT-25). On a dynamic tariff the Cheap hours count guesses where control will charge; a counted slot can still go unused, and that gap comes from the grid.
# OPT-27 - the night plan keeps the last fresh forecast
**Status: done on `release/1.0`, not released.** Tests: `test_opt27.py`.
**The defect.** A today sensor is stale after 3 h (`FRESH_S`) or when it is from
before local midnight. Forecast.Solar stops updating in the evening, so at night
every Forecast.Solar site had no forecast: a price mode's night cheap run needed
1.5x the cycle cost (TARIFF-24 round 2) and Leftover solar planned nothing.
Separately, one missed poll (`unavailable`) dropped the forecast at once.
**Where: `solarfc`, not the plan.** The last fresh reading of each sensor is
kept in `solarfc.Hold` and `read_sum()` uses it when a sensor has none. A hold
at the plan (`_wx_track`/`weather_held`) can only keep the 1.5x gap off. The
day plan, Leftover solar's levels, Home and the Forecast tab all read
`Controller.solar_fc`, so one kept forecast makes control and every screen agree
(UX-53) with no second rule to keep in step. `weather_held()` is unchanged: it
still keeps a run under way when a read is lost.
**The rule** (`Hold.stand_in()`). A kept reading is for one day. It covers a
sensor that is missing or stale, never one with a bad value or unit, and:
- for up to `FRESH_S` when the sensor is missing: a short outage, any time of day;
- from the end of the bell (20:00 local, `BELL_TO_H`) until local midnight, if the
reading is at most `KEPT_MAX_AGE_S` (12 h) old when used; after midnight the
tomorrow figure is today's until the bell starts (06:00), up to 15 h old
(OPT-34 changed this from midnight + 3 h);
- the day it is for: a today figure only on that day, a tomorrow figure as
tomorrow until midnight and, if the today sensors are still stale, as today's
until 06:00 (all sensors of the sum are needed, as for any sum);
- until the next fresh reading, which replaces it at once.
So a figure is never used for another day and never older than 12 hours (`KEPT_MAX_AGE_S`), except the morning case above: a 17:05 reading serves until 06:00 (12 h 55 min), a 09:05 reading only until 21:05. Until OPT-34 the figure ended at 03:00, and a charge under way lost its level there; OPT-34 closes that limit.
Daytime is as before: a sensor that stopped is stale after 3 h, and no forecast
all day is still no forecast (the night run still needs 1.5x).
**Where it is stored.** The controller's store, key `solar_fc_hold`, so an
evening restart keeps it. It is written when a reading's figure changes or
every 15 min (`SAVE_EVERY_S`), not on every poll. A damaged entry is dropped.
**The screens.** `Forecast.kept` is true when a reading older than `FRESH_S` is
in use; the forecast line then reads "Solar forecast read 17:05, kept for
tonight." (`home_words.solar.kept`, EN and NL). The event log says
"read, kept from 17:05".
**Not changed.** Control with modes off: it does not use the forecast. The
screens still show the line, so it says "kept", not "used for the plan". A
forecast that stays fresh. The hold does not look at the weather, only at the clock and the day.
**OPT-38 (2026-11-07).** A kept TOMORROW reading (at most `KEPT_MAX_AGE_S` old, same `day0`) now stands in at any hour, not only from `BELL_TO_H`: one sensor that stopped at 14:54 had dropped the whole sum (OPT-17) from 17:54 to 20:00. Today readings and the OPT-34 morning rules are unchanged; `test_opt38.py`.
A fresh figure that LOWERS the level during a charge still lowers it, as before.
**Mutants** (all red in `test_opt34.py`): no latch; window back to midnight + 3 h;
15 h without a limit; no "usable at midnight" rule; the latch without the narrow
gap, without its save, or not kept through the next run; the window 6 h after
midnight instead of 06:00 local (DST); 15 h cut to 12 h; the new screen line off or shown without a cheap run; no expiry check; no pruning of a changed mode; no night bound; a left-the-plan battery keeping its level; no `replaced()` check (F-1); `replaced()` with one of several today sensors (any, not all).
**The defect (TEST-23, SAFETY-119 rig test F-1).** 5 s meter, 2 x 2500 W,
cap 5000 W, maintenance charge, no forecast, house 5100 W. bee7431 warned
once in 70 min (04:31:01), then not at 04:45, 05:00 or 05:15. Base 75f0804
warned at every quarter start. The loop held the wire once a quarter, at its
start, and was at its bound on 4 or 5 cycles. SAFETY-119's settle (12
cycles, 60 s at 5 s) covered all of them, and 5 cycles a quarter fit in its
budget of 8 per 900 s.
**Why the simulation said "every quarter".** `test_safety119.py` fed the
meter one cycle behind the battery reading (`delay` counts cycles: 5 s at a
5 s meter). Just after the loop leaves its rail, the guard's charge
headroom (house = meter + battery) is then off by up to 5000 W, the charge
pulls 2000 W, the guard steps in again, and the two chase each other: 8 to
10 hand-backs and about 20 bound cycles a quarter at 5 s (rig: 1 and 4-5).
With the meter read in the same cycle (`delay` 0, the rig's shape) the sim
gives the rig's numbers: 3 to 5 bound cycles a quarter at 5 s, all inside
SAFETY-119's settle, and bee7431 warns in 0 to 2 of 7 quarters. The test
now runs both shapes.
**Decision.** After a hand-back the loop's bound is hidden until 4 cycles
(`HANDBACK_CYCLES`) and 22 s (`SHORT_SPAN_S`) have passed; across all
hand-backs on at most 11 cycles (`ROLLING_BOUND_CYCLES`) in any 900 s. The
budget no longer follows the cycle length, and the cycle length is not
tracked. A stop ends the settle and keeps the budget. An over-rating always
counts. Commands are unchanged.
**Why it holds for any number of bound cycles a quarter.** The settle is
fixed: at most 3 cycles or 22 s after a hand-back, whichever is longer. A
bound that lasts past it counts on its first cycle after it. So one
hand-back a quarter, with the loop at its rail past the settle, warns in
that quarter, whether it is 1 bound cycle or 100. A bound that never lasts
past a settle counts once more than 11 are hidden within 900 s. Hidden
are only shapes with at most 11 bound cycles in 900 s, each within 3 cycles
or 22 s of a hand-back. That is the quarter-edge kick: in every steady-meter
run below it is on the 1st to 3rd cycle after its hand-back (up to 30 s at
a 30 s meter). In the rig's shape at 5 s the bound comes 30 to 55 s after
the hand-back.
**Sweep** (`goodwe-addon-checks:1`, 2 h runs, scratch/SAFETY-121/dev/).
Quarter edge = test_safety119 part 1 (house 800 W, cap 2500 W, no
forecast). Overload = part 4 (2 x 2500 W, cap 5000 W, house 5050 or
5100 W, seeds 0-3). "Delay 1" is the old sim, "delay 0" the rig's shape.
| meter | quarter edge, runs with a warning (new / bee7431 / no fix) | overload delay 1, quarters warned of 7 (new / bee7431 / no fix) | overload delay 0, 5100 W (new / bee7431 / no fix) |
# SAFETY-94 - a battery that lags or reverses is not frozen or refusing
**Status: implemented 2026-10-03, for review.** Tests: `test_safety94.py`
(rig: `tools/safety94_rig.py`). Also closes SAFETY-58. SAFETY-74 stays open.
## The defects
1. **Stale-reading gate (SAFETY-37).** Its 35 s ran from the register's last
change. After a rest that clock was already past 35 s, so the first read
after a new command tripped it, before the register could answer. Live
2026-10-03 (0.14.0, N=2): 17:39:16 B and 17:39:25 A (load ramp after a
rest), 19:00:04 A (drain start), 21:21:22 B (drain -> charge). Each was
1 s after its command; each register answered within 11 s. This is
SAFETY-58's shape.
2. **Refusal at N=1 (SAFETY-52).**`compute()` engaged after `SETTLE_CYCLES`
frozen cycles if the reading was under 100 W at that moment. The frozen
cycles include a reversal through the battery's lag. At a 1 s meter the
12th cycle comes as a battery reversing out of a charge passes 0 W
(SAFETY-85 rig, O1: "gave -20 W for 13 cycles"). The refusal then held
0 W, the battery settled at 0 W, never gave 100 W, and waited for the
15-minute probe. N>1 already required 22 s in the band, so it was safe
at a 10 s lag but not at 20 s.
## What changed
- **The gate counts only time the register was asked to move**
(`freshness.Freshness._oblige`). A read counts the time since the last
read when, at that read, the command is 250 W or more and has moved 250 W
from where it stood at the register's last change. A register change
(or a SAFETY-57 release) restarts the count. A command flapping in and
out of the ask still adds up (frozen register, 0/1500 W every 5 s: trip
at 69 s). The conjunction, `MOVE_W` and `RELEASE_S` are unchanged.
- **The bound is unchanged at 35 s and now means what its derivation
says.** The floor was always "how long a healthy register takes to answer
a command": 6 s plant + 10 s publish + 1 s read = 17 s. The band
`[2 x 17, 0.5 x 75] = [34, 37.5]` holds. Live answers measured: 1.4, 3,
6 and 11 s after the command.
- **Refusal evidence is the same at every roster size**
(`main.Controller._gave_nothing`, SAFETY-73's count moved into a method).
The reading must stay under 100 W, one way, while asked over 200 W, for 12
cycles spanning 22 s. At N=1 `compute()` gets this as `gave_nothing` and
needs it on top of its own freeze test. `None` (compute alone) keeps the
old law.
- **The evidence restarts when the reading moves 50 W towards the ask**
(`REFUSED_PROGRESS_W`). A refusing battery reads flat (-3/-4 W live). Live
readings wander by under 25 W at rest. A first-order lag crossing the band
gains 50 W in at most 0.4 tau, so it cannot fill 22 s unless tau > 54 s.
This also covers B, whose reading is 100 W below its power.
## Bounds and worst-case catch
| fault | before | after | budget |
|---|---|---|---|
| register frozen, then asked to move | 0-35 s after the ask (often 1 s) | 35 s after the ask (+1 read) | SAFETY-37: 35 s, under the 75/85 s consumer holds |
| register frozen at rest reading ~0 W | stale 1 s after the ask | refused or stale, 0 W within 23-35 s | the same |
| refusing battery, 1 s meter, N=1 | 11-16 s | 22-28 s | SAFETY-73's 22 s span (+ one 10 s publish) |
| refusing battery, 2 s meter | 22-28 s | 22-28 s | unchanged |
| refusing battery, 5 s meter | N=1 35-41 s, N=2 41-55 s | N=1 40-45 s, N=2 50-55 s | 12 cycles = 55-60 s |
Rig: `test_safety94.py` part 3. A release after SAFETY-57 still exposes
the held number for one 35 s window of asking, so 35 < 75 < 85 still holds.
## Before -> after
- Live replay (part 1): 4 trips -> 0.
- Refusing B (its -100 W idle reading): see SAFETY-97.
- Rig, 10 s lag, N=1 and N=2, 1/2/5 s meters, two register shapes, 48 runs
(part 2): before 27 stale trips and 1 refusal, after 0 and 0.
- Reversals, lag 10 and 20 s, 1 s meter (part 2): before N=1 6 stale / 3
@@ -78,3 +78,15 @@ The allowlist is empty and its cap is 0 (43 → 0). Every WARNING and ERROR line
7. **Review: the line as logged gets the shape too.** Part 6 first checked the quoted reason alone, so a title, a 2-sentence reason and two tails still logged as 4 sentences ("Power request too high …: OUTPUT_CLAMP: … +5000 W. The command this cycle was +1000 W. Control is still running. Cut back 1 time so far."). Part 6 now also checks the whole line: at most 3 sentences, none over 30 words. The wrappers became one sentence each, the circulation and peak guard reasons two, and `STALE_READING`'s fixed limits moved from the reason to a DEBUG line beside the ERROR (its release clause stays, pinned by test_freshness). The clamp lines for one inverter are pinned at 30 words at most: `OUTPUT_CLAMP: computed +9000 W, cut to the +5000 W rating, command now +2000 W`. Several clamped inverters read as one sentence of asked/sent pairs; which limit bound each is on its own action-log row and in the notification. Totals above 30 words remain on the direction, delivery, frozen-meter and stale lines (up to 74 words). Shortening them is a follow-up: the direction and delivery reasons are also persisted in state.json, and the direction one is pinned byte-for-byte in test_watchdog.
8. **Home Assistant 400 while it loads** now reads "Home Assistant refused number.set_value for number.x (error 400, no details). The entity may still be loading, or the value is out of range." A body with more than "400: Bad Request" is still quoted. Still WARNING, still once a minute, still a failed write.
9. **Witness** (admin/goodwe): the resolved push says "after no answers from … to …", as the resolved card does. The YAML with every title and message stripped is identical.
# UX-11: safety log lines give the code, the figures go to DEBUG
**Unchanged:** every trigger, latch, threshold and alarm log level (the WARNING and ERROR lines stay), every notification id and cadence, every row colour and the banner cascade. No notification is added.
1. **One plain sentence and the code.** A WARNING/ERROR line that reports a safety reason (direction, delivery, stuck meter, stale reading, peak guard, circulation, over-rating) now ends in the reason's code, taken by `messages.reason_code()`. The reason itself, figures and limits included, is on a DEBUG line logged right after it ("Evidence for inverter-a: …"), and the action log entry carries it as before. Part 6 checks that pairing in the code. Circulation and the clamp lines were not among the five named, but they break the same 25-word rule, so they follow the same pattern. The clamp numbers stay in the notification (phase 2a item 3).
2. **The reasons and `state.json` are unchanged.**`reason` stays the evidence text, so what is saved has the same format as before. An old state file therefore loads and displays like a new one: every saved reason has opened with its code since it was first written (checked in the git history), and that code is all the ERROR line reads. The saved text goes on the DEBUG line. A stop saved without a reason shows `REASON_NOT_SAVED`. `test_messages.py` part 7 restarts from a state file holding the old long texts. `test_watchdog.py` pins the meaning (the code first, then command, reading, time and both limits, in that order) and, since the text did not change, still the bytes.
3. **The 25-word rule is checked as logged.** Part 6 fails any WARNING+ line over 25 words with its built text filled in. Nine non-safety families still run long (tariff plan words, price feed reasons, the state migration report, write refusals and claim scope errors that only a software fault raises, maintenance, trading gate and price history reasons). They are listed with a reason in `LONG_LINE_OK`, capped at 9, and a listed family that gets shorter fails until it is removed. Shortening them is a follow-up.
4. **The meter row's "the add-on log shows why" is now true.** When the meter goes quiet past its limit, the add-on logs one WARNING per episode, not one per cycle, and an INFO line when readings return. A meter that flaps (on `ha_signed` a healthy meter under a flat load can go 42–97 s between changes) logs at most one such pair per 10 minutes, and the episodes in between go to DEBUG. This is a new log line, not a new alarm: it has no notification and changes no decision.
5. **The Why line past the 15 s hold** names the missing reading ("No usable meter reading for over 15 seconds: 0 W", or the battery power or level of an inverter), instead of "A reading is missing: 0 W".
6. **Action log:** "25 engagement(s)" is "25 engagements", and "SHADOW MODE OFF - …" is "Shadow mode off: …". "SHADOW MODE ON" was not named in the card and is left as it is.
7. **Review: after a restart the figures go on the action log too.**`log_level` defaults to `info`, so the DEBUG evidence line is not seen by default, and `events` starts empty. Each restored stop (direction per inverter and site, delivery, circulation) now also writes its saved reason to the action log ("FAILSAFE inverter-a, saved before the restart: …"), and the page's event line gets the same plain words the live stop gives. `LONG_LINE_OK` also refuses a key whose text is a safety reason, not only a `reason_code` key.
Drives a GoodWe ES/BP battery inverter over its RS485 meter bus: holds net grid
exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
balance cells and recalibrate its coulomb counter.
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port: sends it a grid
reading to hold net grid exchange at zero, and runs a monthly battery
maintenance cycle so the BMS can balance cells and recalibrate its coulomb
counter.
Installers: the printed field guide (`docs/GoodWe-RS485-Field-Guide.pdf`) is
v0.1.0 and outdated; where it disagrees with this page, this page wins.
@@ -33,8 +34,8 @@ v0.1.0 and outdated; where it disagrees with this page, this page wins.
You need:
- A GoodWe **ES / BP family** inverter (AA55 / RS485 meter-bus generation)
- The vendor's meter-emulating controller **disconnected** from the bus
- A GoodWe **ES / BP family** inverter (AA55 generation)
- The vendor's controller **disconnected** from the inverter's EMS port
- A control board: a T-CAN485 (ESP32) flashed with
`firmware/goodwe-master.yaml`
- A grid-power sensor already working in Home Assistant, updating every ~5–10 s
@@ -183,6 +184,12 @@ The label and description each setting shows on the Configuration tab, in tab or
| Hardware · Inverter list | Battery power sign is reversed (optional) | `inverters.batt_invert` | Switch this on if this inverter's sensor shows giving power as a negative number. |
| Hardware · Inverter list | Usable battery capacity (kWh) (optional) | `inverters.capacity_kwh` | This battery's usable capacity from its datasheet. Fill it in on every inverter or on none. The add-on then shares the work by the energy each battery has left. |
| Hardware | RS485 emergency stop is fitted | `estop_fitted` | Switch this on if the emergency stop is installed. It only changes a warning on the status page. |
| Hardware | Battery modes | `battery_modes_enabled` | Give each battery an on and off switch and a mode, set on the Batteries screen. |
| Hardware | Solar forecast, today (kWh) | `pv_forecast_entity` | Optional. A forecast sensor with today's remaining solar energy, such as Forecast.Solar or Solcast. A battery then buys only what the sun will not give. |
| Hardware | Solar forecast, tomorrow (kWh) | `pv_forecast_tomorrow_entity` | Optional. The same forecast for tomorrow. It helps plan a cheap hour before midnight. |
| Hardware | Several solar forecasts, today (kWh) | `pv_forecast_entities` | Optional. One row per forecast sensor, such as one per inverter, used instead of the single one above. They are added up. |
| Hardware | Several solar forecasts, tomorrow (kWh) | `pv_forecast_tomorrow_entities` | Optional. The same list for tomorrow. If one sensor has no reading, that day's forecast is not used. |
| Hardware | Trust in the forecast (%) | `solar_trust_pct` | Forecasts are often too sunny. At 70 % the add-on plans with 7 of every 10 kWh forecast. |
| Hardware | Solar production entity (W) | `pv_entity` | Optional. Your solar inverter's power sensor, positive while producing. The add-on records it and does not use it for control. |
| Hardware | Solar production entities, per inverter (W) | `pv_entities` | Optional. Use one row per solar inverter instead of “Solar production entity” when you have several. If one stops reporting, no total is recorded. |
| Hardware | Reversed-sign solar entities | `pv_invert_entities` | Optional. Add each solar entity above that reads negative while producing, spelled the same way. Its sign is flipped before adding up. |
@@ -203,7 +210,8 @@ The label and description each setting shows on the Configuration tab, in tab or
| Limits | Inverter rating (W) | `max_w` | Your own number: the most power the add-on may ever ask of the inverter. Start low and raise it after commissioning. |
| Limits | Battery cut-out level (%) | `bms_soc_floor` | The level where the battery's own management system stops giving power. Read it off your battery rather than copying a figure. |
| Limits | Peak limit (W) | `peak_cap_w` | Your own number: the 15-minute average power the add-on keeps the grid under. Take it from your grid contract. |
| Limits | 15-minute demand forecast entity (W) | `peak_forecast_entity` | Optional. A forecast of this 15-minute period's average power. Leave it empty and there is no peak limit. |
| Limits | Margin below the peak limit (W) | `peak_margin_w` | The add-on aims this much below the peak limit, so a 15-minute period that ends a little high still stays under it. |
| Limits | 15-minute demand forecast entity | `peak_forecast_entity` | Optional. A forecast of this 15-minute period's average power, in W or kW. With no power unit it is not used. Leave it empty and there is no peak limit. |
| Limits | Peak reserve (%) | `peak_soc_floor` | Peak limiting will not draw the battery below this level, but ordinary use can. Derived value, leave it unchanged. |
| Tariff | Dynamic price source | `price_provider` | Where prices come from. Choosing a source starts the price fetch, even with trading off. |
| Tariff | Supplier markup (EUR/kWh) | `price_markup_eur_kwh` | Your supplier's margin. It is added only when the price source does not already include it. |
@@ -215,6 +223,7 @@ The label and description each setting shows on the Configuration tab, in tab or
| Tariff | Your own injection formula | `price_export_formula` | Optional. The injection formula from your tariff card, in the same shape as your own tariff formula. Leave it empty to use the flat injection price. |
| Tariff | Price CSV file | `price_csv_path` | For manual_csv only. Where in /share the add-on reads your price file. |
| Tariff | Price feed URL override | `price_feed_url` | Leave it empty to use the source's own feed. An override is sent exactly as typed and often returns only one day. |
| Tariff | Price service token | `price_service_token` | For the price service only. The token you were given for it. Leave it empty with any other price source. |
| Tariff | Price look-ahead (hours) | `price_horizon_h` | How many hours of prices to ask the source for. |
| Tariff | Price request timeout (s) | `price_timeout_s` | How long one request to the price source may take before it is given up. |
| Tariff | Current price entity (older) | `price_now_entity` | The older way to get a price, used only to charge in a cheap window during maintenance. Do not combine it with a dynamic price source. |
@@ -225,7 +234,7 @@ The label and description each setting shows on the Configuration tab, in tab or
| Tariff | Trading charges at most (%) | `arbitrage_soc_ceiling` | Price trading will not charge the battery above this level. |
| Maintenance | Run the monthly battery cycle | `maintenance_enabled` | Once a month, empty the battery deeply, charge it full and hold it there, so its level reading stays accurate. Off by default. |
| Maintenance | Minimum days between cycles | `maintenance_interval_days` | The shortest gap between two maintenance cycles. |
| Maintenance | Start hour | `maintenance_start_hour` | The local hour, 0 to 23, at which a due cycle starts. |
| Maintenance | Start hour (local time) | `maintenance_start_hour` | The hour on your local clock, 0 to 23, when a due cycle starts. 19 means 19:00. |
| Maintenance | Draw-down rate (W) | `maintenance_discharge_w` | How fast the cycle empties the battery. Above “Inverter rating” it is cut back to the rating, and the cycle just takes longer. |
| Maintenance | Recharge rate (W) | `maintenance_charge_w` | How fast the cycle recharges the battery. It must be at or below “Inverter rating”, or the add-on will not start. |
| Maintenance | Draw down to (%) | `maintenance_soc_floor` | The level the monthly cycle empties the battery to. It is not the “Peak reserve”, and the two differ on purpose. |
@@ -242,6 +251,15 @@ The label and description each setting shows on the Configuration tab, in tab or
| Safety | Opposing inverters time (s) | `circulation_hold_s` | For two or more inverters: how long they may push against each other before a safety stop. Derived value, leave it unchanged. |
| Safety | Not delivering alarm after (s) | `delivery_hold_s` | For two or more inverters: how long one may fall short of its share before an alarm, which changes nothing. Derived value, leave it unchanged. |
| Safety | Shadow mode | `shadow_mode` | The add-on makes every decision but keeps every inverter at 0 W. 'auto' does this while control is stopped, 'on' always, 'off' never. |
| Car charger | Charger | `ev_charger` | Which car charger the add-on drives. Off leaves everything as it is. In Off mode the add-on only reads the charger and never changes it. |
| Car charger | Current setting entity | `ev_current_entity` | The entity that sets the charger's current. The add-on finds the charger's other entities from its name. |
| Car charger | Charger limit (A) | `ev_max_a` | The most current the charger may ever be asked for. Never above what the charger reports. Lower it for a weaker fuse or cable. |
| Car charger | Phases | `ev_phases` | How many phases the charger may use: 1, 3, or 1 and 3 (auto). |
| Car charger | Batteries help with the peak | `ev_batt_cover` | While the car charges. On: the batteries cover it down to the peak reserve. Off: the peak guard leaves the car out, so the car alone can set the peak. |
| Car charger | Mode after a restart | `ev_mode_start` | Keep the last mode, or start in Off. A restart in Solar sets the charger to 0 A first, other modes leave its current. |
| Car charger | Sun kept back (W) | `ev_margin_w` | Solar: this much spare sun is never given to the car. |
| Car charger | Start after (minutes) | `ev_start_min` | Solar: the car starts after this long with enough spare sun. |
| Car charger | Pause after (minutes) | `ev_pause_min` | Solar: with too little sun the car holds 6 A this long, then pauses. |
| Advanced | Start control on boot | `auto_start` | Off by default. Leave it off until the site is commissioned, so someone presses Start after each restart. |
| Advanced | Control gain | `gain` | How much of the remaining error control corrects each cycle. Measured on real hardware, do not raise it. |
| Advanced | Largest change per cycle (W) | `slew_w` | How far the command may move in one cycle. 0 follows “Inverter rating” and is recommended. |
@@ -273,6 +291,7 @@ When the add-on refuses to start, each reason names the setting by its label and
- **Inverter rating** (`max_w`): your own number, not a derived one. It is not read when the inverter list is filled in, since each entry carries its own and the site limit is their sum. Several safety thresholds must stay below it, and the add-on refuses to start if one does not.
- **Battery cut-out level** (`bms_soc_floor`, `inverters.bms_soc_floor`): measured, not chosen. Register 0x0560 reads 10 % on the reference GW5000S-BP. It exists so the add-on can refuse a “Peak reserve” at or below it, which could never take effect. Each inverter entry states its own, because one default for two different batteries protects the shallower one with the deeper one's number.
- **Peak limit** (`peak_cap_w`): your own number, from your grid contract. In Belgium it is the capacity-tariff peak your distribution charge is billed on.
- **Margin below the peak limit** (`peak_margin_w`): 50 W by default, 0 to 500 W (SAFETY-79). Peak limiting aims at the peak limit minus this margin, because a 15-minute period aimed exactly at the limit can end a watt or two over it (3501.9 W against 3500 W in a test), and even 1 W over sets the billed peak. Once this month's peak is already above the limit, it aims the same margin below that peak. The bill, this month's peak and the warnings still compare against the peak limit itself. 0 aims at the limit, as before.
- **Peak reserve** (`peak_soc_floor`): derived, not picked (SAFETY-24). The reference battery holds 13.8 kWh usable and the worst modelled peak day asks for 878 Wh, or 6.4 %. 20 % sits ten points above the cut-out level and leaves about 1.6 worst days of room. It bounds peak limiting only: ordinary use goes on down to the cut-out level. It must stay above “Battery cut-out level”.
- **Dynamic price source** (`price_provider`): selecting a provider is what starts the fetch, every half hour, whether or not trading is on. It may not be combined with the two older price entities. engie_dynamic, totalenergies_dynamic and eneco_eddy are withdrawn and refuse to start: their endpoints never existed. They stay in the list only so such a site gets that explanation.
- **Supplier markup** (`price_markup_eur_kwh`): under manual_csv, whose prices are all in, it is ignored and logged as ignored.
@@ -282,6 +301,7 @@ When the add-on refuses to start, each reason names the setting by its label and
- **Fixed or day/night tariff** (`static_profile`): the periods must cover every day type exactly once with no gap and no overlap, and a gap is refused rather than filled. A window 22:00-07:00 on mon-fri does not cover Saturday morning, so a weekend row is required. See [Static day/night and fully-fixed tariffs](#static-daynight-and-fully-fixed-tariffs-static_profile).
- **Your own tariff and injection formula** (`price_formula`, `price_export_formula`): type the card's numbers in the card's units. The `card` block is required on the tariff formula: the add-on recomputes the card's example price and refuses to start if it does not come out. Injection is VAT-exempt in Belgium, so `vat_pct` there is normally 0. See [Your own tariff formula](#your-own-tariff-formula-custom_formula) and [`price_export_formula`, field by field](#price_export_formula-field-by-field).
- **Price feed URL override** (`price_feed_url`): only a host the chosen source declares is accepted. Nothing is added to the URL, not even the date range, so an override often returns one day and the rest of the plan is carried over and excluded from trading. The log warns on every refresh.
- **Price service token** (`price_service_token`): a password field. Every page of the add-on, and every answer its web app gives, shows only `********` when a token is set and nothing when not; the token itself is never sent to a page. A save that leaves the field empty or as `********` keeps the stored token, and a new value replaces it. It must be at least 16 characters. It is needed with `price_provider: price_service`, and the add-on refuses to start without it. It never appears in the log, the status page, a refusal or a notification. See [`price_service`](#price_service--your-own-price-server-and-what-it-falls-back-to).
- **Current and average price entities** (`price_now_entity`, `price_avg_entity`): kept because removing them would take the maintenance cycle's only price signal away from a live site.
- **Trade on the price spread** (`arbitrage_enabled`): off as shipped, on purpose, because it moves energy against the meter by design. It needs a price source and a P1 meter, and the add-on refuses combinations that cannot work.
- **Battery cycle cost** (`cycle_cost_threshold_eur`): wear plus conversion losses. It is not derived from a measurement: 0.10 is a product decision still open with the owner (OPT-08). At this value a fixed day/night site does not trade, since a realistic Belgian day/night spread is about 0.08 EUR/kWh.
@@ -295,7 +315,7 @@ When the add-on refuses to start, each reason names the setting by its label and
- **Stuck meter alarm after** (`meter_freeze_s`): measured, not chosen (SAFETY-18). Over 2399 s of this house at its operating point, the longest run without a new reading is 15.4 s, and 300 s is 19.5 times that. It raises an alarm only and does not set 0 W.
- **Opposing inverters threshold** (`circulation_w`): measured on 924 closed-loop test runs (SAFETY-31). The worst legitimate opposition drops from 505 s at 100 W to 5 s at 400 W, the lowest value accepted. 700 W is 1.75 times that knee, with margin because the second inverter is still a copy of the first.
- **Opposing inverters time** (`circulation_hold_s`): derived (SAFETY-31). 75 s is fifteen control cycles, 15 times the worst legitimate episode, and 2.5 times the control board's 30 s link limit.
- **Not delivering alarm after** (`delivery_hold_s`): two or more inverters only. It reports only (SAFETY-42): nothing is commanded differently. Derived from 2640 closed-loop test runs with nothing faulty. The worst legitimate episode is 35.0 s and 185 s is 5.29 times that. The schema allows 30 s, below that, so expect false reports there. A battery at or below its own cut-out level is never reported. Re-derive with admin/goodwe `sim/delivery_window.py --campaign --blag`.
- **Not delivering alarm after** (`delivery_hold_s`): two or more inverters only. It reports only (SAFETY-42): nothing is commanded differently. Derived from 2640 closed-loop test runs with nothing faulty. The worst legitimate episode is 35.0 s and 185 s is 5.29 times that. The schema allows 30 s, below that, so expect false reports there. A battery at or below its own cut-out level is never reported, and neither is one that gives under 100 W (SAFETY-73: it is a battery that refuses). Re-derive with admin/goodwe `sim/delivery_window.py --campaign --blag`.
- **Shadow mode** (`shadow_mode`): the whole decision path runs and nothing reaches the inverter. The status page and action log show what would have been sent. A safety stop that is already up stays up. See [Shadow mode](#shadow-mode-shadow_mode).
- **Control gain** (`gain`): measured on real hardware and already at the limit.
- **Largest change per cycle** (`slew_w`): 0 means follow the rating: about a ninth of it, derived (SAFETY-39) from a measured ~18 s step response against a 2 s meter tick. A fixed value faster than the rating allows is refused. At 1000 W against a 5000 W rating control swung the meter from 3.4 kW export to 2.8 kW import on 2026-09-05.
@@ -512,6 +532,57 @@ two of a thing there is one of, and `P1 sample age` is a safety input. Same for
status, the maintenance phase, the capacity-tariff peak and the three loop rows
below.
### Battery modes (`battery_modes_enabled`)
Off by default. Turn it on, restart the add-on, and the Batteries screen (and Settings, Simple) gives each battery two controls. They apply at once, with no restart.
- **On or off.** Off asks the battery for 0 W and starts no monthly cycle on it. A cycle that is running stops, and the add-on log says so. The peak limit may still use it, but only for what the other batteries cannot cover.
- **Mode.**
- *Solar first* charges from spare solar before the other batteries and covers the house at any hour. It never charges from the grid and never sells.
- *Leftover solar* charges from the solar the others cannot take. With a solar forecast it may also charge from the grid, but it buys only what the sun will not give in the expensive hours (see below). It saves its power for those hours and covers the house then.
- *Cheap hours only* fills up from the grid in the cheapest hours, saves its power for the expensive hours and covers the house then. It does not look at the forecast.
- **Selling** is off until it can be judged on the price the grid pays (owner decision 2026-09-29, option A).
With battery modes on, these choices replace the *Charging and selling on price* switch (`arbitrage_enabled`); that switch is only read with modes off.
**Cheap and expensive hours.** They come from the published day-ahead prices, as runs of consecutive 15-minute periods, not a single period.
- The cheap run is the cheapest stretch long enough to fill the batteries that may charge, at their power.
- An expensive hour costs more than the cheap run by at least *Battery cycle cost* (`cycle_cost_threshold_eur`) when a solar forecast is read, and by 1.5 times that when none is (a real-time price feed widens it further). The batteries hold their power until then.
- The sale uses the most expensive stretch inside those hours, and never a period below 0.
- A carried (not yet published) price is never used. A run that has started runs to its end.
- With no prices, or too small a gap, every battery follows the house.
**Solar forecast** (`pv_forecast_entity`, optional). A Home Assistant sensor with the solar energy still to come today, in kWh. These work: Forecast.Solar (`sensor.energy_production_today_remaining`), Solcast PV Forecast (`sensor.solcast_pv_forecast_forecast_remaining_today`) and Open-Meteo Solar Forecast (`sensor.energy_production_today_remaining`). Set `pv_forecast_tomorrow_entity` to the matching *tomorrow* sensor to plan a cheap run before midnight.
- **Several forecasts.** If your forecast comes as several sensors (one per inverter or roof side), list them in `pv_forecast_entities` and, for tomorrow, `pv_forecast_tomorrow_entities`, instead of the single key. They are added up, each in its own unit (Wh, kWh or MWh). Set the list or the single key for a day, not both.
- If one of them has no reading, is stale or is not in an energy unit, that day's forecast is not used at all. A part of the sun is not counted as all of it. The status page names the source by its place in the list.
- The hourly shape is kept only if every sensor has one. Otherwise the total is spread over the day as for Forecast.Solar.
- Before each cheap run the add-on asks: will the sun fill the batteries before the expensive hours? It counts on `solar_trust_pct` of the forecast (70 %), less what the house uses. Solar first batteries get that sun first.
- *Leftover solar* then charges from the grid only the shortfall: for each expensive hour, what the house uses less the sun counted for that hour (never below 0), added up over all the expensive hours, early morning and evening. With a day and night tariff that is 07:00 to 22:00. Not up to the top level.
- All *Leftover solar* batteries hold that shortfall together, shared by their size. A battery that reaches the top level passes the rest to the others. If all of them together cannot hold it, they all fill to the top level. *Cheap hours only* and *Solar first* batteries give first: what they will hold when the expensive hours start (a *Cheap hours only* battery full, or as far as it can charge under the peak limit in the cheap hours left; a *Solar first* battery after the night's use) is taken off the shortfall. In the expensive hours the rest comes from the grid. The Batteries screen says so. The sun before the expensive hours still fills first, and is taken off what is bought.
- A forecast that gives only one figure for the day (Forecast.Solar) is spread over the hours from now, so the hours add up to that figure.
- *Cheap hours only* ignores the forecast and fills to the top level.
- *Solar first* never charges from the grid.
- The house use is the add-on's own measurement (grid + battery power) per hour, over the last 7 days. It needs one day of it before the first plan.
- The plan is checked every 15 minutes. A planned level moves only by 1 kWh or 10 %, so a wobbling forecast does not flip it.
- No forecast, one older than 3 hours or from before midnight, or no house use yet: *Leftover solar* takes solar only and *Cheap hours only* fills to the top level. The Batteries screen says so.
- A battery needs its capacity (`inverters.capacity_kwh`) for a plan.
- **At night.** Some forecasts stop updating in the evening (Forecast.Solar does). The add-on keeps the last reading of each sensor and uses it for that night's plan: from 20:00 until 06:00, or until a newer reading comes. After midnight the evening's figure for tomorrow is today's, whole, because nothing has been produced yet. A sensor that is missing for up to 3 hours is covered the same way. A figure is never used for another day, and never when it is more than 12 hours old (15 hours after midnight, for a figure that was still in use at midnight). A charge from the grid that has started keeps its level when the forecast ends, and goes on to it; the Batteries screen says so. The Batteries screen says "Solar forecast read 17:05, kept for tonight." With no reading all day, the night run still needs the wider gap.
**What always comes first.**
- The peak limit, the safety stops and the monthly cycle come before a battery's mode.
- A grid charge is sized so the 15-minute period stays under the peak limit less its margin (`peak_margin_w`). It starts only at 500 W or more. Once the peak limit stops it, it stays off for the rest of that 15-minute period. The start of a new period does not stop it.
- While one battery charges from the grid, the others rest, and the house uses the grid.
- While one battery empties for its monthly cycle, no battery charges from the grid.
- A battery that refuses to charge or give power takes no part in a run in that direction. In a cheap run it is still tested every 15 minutes: it charges at 200 W for about half a minute while the others rest.
**In Home Assistant.** With MQTT set up, each battery also gets a *Mode* list and a *Use* switch, for example `select.goodwe_inverter_a_mode` and `switch.goodwe_inverter_a_use`. They do the same as the Batteries screen. Turn battery modes off and restart, and they are removed.
*For installers:* commands arrive on `goodwe_ctl/unit/<battery>/mode/set` (a *Mode* option, such as `Solar first`) and `.../use/set` (`ON` or `OFF`). They go through the same checks as the Batteries screen. A refusal is logged once, and later refusals are counted in the log. A retained command is never applied, so the broker cannot replay an old choice after a restart; the add-on keeps the last choice itself.
*For installers:* a mode is a limit at priority 35, kept apart from the hard limits. It gives way only as far as a limit above it (the peak guard) needs. A mode range always holds 0 W, so a mode can forbid a direction and never force one. With one inverter the mode also bounds the loop. The record is `DECISIONS/OPT-11-battery-modes.md`.
*For installers:* when a charge or sale ends, the loop restarts at the house's own level rather than at the trade's watts, and holds there until the meter shows the change (at most 18 s, up to 36 s while the battery is still moving). This removes the ~3 kW import spike after a 2.5 kW charge and the export overshoot that readings a second or two old caused (-1120 W on the test rig); with the hold it stays within 0.15 × the battery's power. The *Mode* list gains *Cheap hours only* in Home Assistant, at the end.
The control law is a bounded integrator: an accumulator that is **not** the
@@ -526,7 +597,7 @@ accumulator is doing:
| `Loop integrator lead` | W | that value minus **the command it was computed against**, i.e. the command the previous cycle left standing |
| `Loop reason` | — | the law's own word for this cycle |
`Loop reason` takes one of eight values:
`Loop reason` takes one of eleven values:
| value | what happened |
|---|---|
@@ -537,7 +608,45 @@ accumulator is doing:
| `slew-limited` | the command could not move as far as the integrator asked for; `slew_w` is what stopped it |
| `saturated-freeze` | the inverter is not following, so the command's magnitude may fall but not rise |
| `freeze-released` | the freeze had run out of plant-shaped explanations and the command was let move again |
| `mode-bound` | the batteries' limits set the command, not the meter: their battery modes, or, with two or more inverters, a battery in its monthly maintenance |
| `not-running` | control is stopped **and** shadow mode is off, so the loop did not run |
| `battery refuses` | the battery gave less than 100 W for 12 cycles and at least 22 s (a minute at a 5-second meter) while asked for more than 500 W, so the add-on asks 0 W in that direction (see below) |
| `battery probe` | the add-on asks 200 W to test whether a refusing battery gives power again |
**When the battery refuses.** At its cut-out level the battery gives nothing,
whatever it is asked. The add-on then asks 0 W instead of repeating its last
request, and the `Why` row reads *The battery refuses to give power: 0 W*. Every
15 minutes it asks 200 W for about half a minute. Control resumes as soon as
the battery gives 100 W or more, when the grid needs charging instead, and when
control is stopped or started. 200 W is below the 250 W the stale-reading check
needs, so a test never trips it. A battery that gives some power, even 100 W,
is not refusing and keeps its request. Nor is a battery whose reading is
still moving towards the request, such as one turning from charging to
giving (SAFETY-94). "Gives" is counted from what the battery's reading shows
at rest, which the add-on learns after two quiet minutes and keeps: some
inverters show about -100 W at rest (SAFETY-97).
While another task sets the power, such as a maintenance charge, the peak
guard or a trade, the refusal stays as long as the battery still refuses that
task's request. It is logged once, and the 200 W test waits until control sets
the power again (SAFETY-107).
**With two or more inverters** the same rule works per inverter. An inverter
whose battery gives less than 100 W for 12 cycles, and at least 22 s, while
asked for more than 200 W is asked 0 W, and the other inverters take over its share, each up to
its own limits. The status page names it: *inverter-a: the battery refuses to
give power, the others take over*. It is tested at 200 W every 15 minutes, one
inverter at a time, and only while the site asks at least 200 W that way.
It still accepts charge, and 12 cycles of charging end the refusal. When every
inverter refuses the same way, the whole site asks 0 W as with one inverter.
If the battery refuses to give power while its level reads above its “Battery
cut-out level”, the log adds one warning ending in `REFUSES_ABOVE_CUT_OUT`: check that setting.
A battery that refuses is not reported as *not delivering*.
*For installers:* SAFETY-52, SAFETY-73 and SAFETY-107. The event log reads
`BATTERY REFUSES …` and `BATTERY REFUSES ENDED …` (with the inverter's name at
N>1), and the INFO line ends in `BATTERY_REFUSES`.
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures and
`DECISIONS/SAFETY-73-refusal-per-inverter.md` the two-inverter ones.
⚠️ **`Loop reason` is not the `Why` row on the status page, and the two will
often disagree.** `Why` is the *arbiter's* answer in words — *Keeping the grid
@@ -1558,19 +1667,52 @@ help - see "Why the tuning is what it is".
|---|---|---|
| `maintenance_enabled` | false | Enable the monthly cycle |
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
| `maintenance_start_hour` | 19 | Local hour a due cycle begins (see below) |
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). The peak guard may ask for more (SAFETY-83; at N≥2 while another battery is at its peak reserve, SAFETY-87), and at N≥2 so may the house while another battery is at its peak reserve (SAFETY-91). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor. ⚠️ **This is not `peak_soc_floor`.** It is the depth the monthly recalibration deliberately goes to, once, on purpose; `peak_soc_floor` is the depth a money-saving discharge may never reach on any day. The right values differ (11 vs 20 as shipped), which is why they are two keys |
| `maintenance_soc_target` | 99 | Charge target |
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
**The start hour is local time.** The add-on reads Home Assistant's time zone
(Settings → System → General) at startup. If Home Assistant does not answer,
it uses the add-on's own time zone, and failing that UTC. The log says which
one it used, and warns if it is UTC: then restart the add-on once Home Assistant
is up. On the day the clocks go forward, a start hour that does not exist
starts at the first hour after the jump. On the day they go back, a repeated
hour starts only once, in its first pass. With two inverters both batteries use
the same local hour; one cycles at a time, and the other starts at that hour on
a later day.
**Upgrading.** The hour used to be read as UTC. An existing install keeps its
saved hour, and that hour now means local time: a saved 10 now starts at 10:00,
not 12:00 in summer. The new default, 19, only reaches installs that have no
hour saved. If you set an earlier hour to get an evening start in UTC (for
example 17 for 19:00 in summer), set it to 19. The add-on never changes a saved
**When the charge counts as done.** A battery may stop at 98 or 99 % while it
balances, so it need not reach `maintenance_soc_target`. The charge counts as
done when the battery is within 3 points of the target and has taken no more
charge for 60 minutes of charging time, or when the charging time (36 hours) runs
out within 3 points of the target. Only the minutes the cheap-hours gate let the
battery charge count, and the charge ends after 7 days at the
latest. Then the usual hold follows.
**When a cycle fails.** If the battery does not empty in 12 hours, or does not
get within 3 points of the target in 36 hours of charging time, the cycle
stops, you get the notification *Battery cycle did not finish*, and it is not
tried again for 7 days. The status page shows *Maintenance paused* with the
date. Starting a cycle by hand ignores the wait. *For installers:*
DECISIONS/MAINT-13-full-pack-is-complete.md.
### Tariff (all optional)
| option | meaning |
|---|---|
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Empty = no cap |
| `peak_forecast_entity` | Quarter-hour demand forecast, for capacity-tariff markets. Read in its own unit (W, kW or any power unit). No unit, or a unit that is not power, means it is not used, as if empty (SAFETY-118). Empty = no cap |
| `peak_cap_w` | The site's capacity-tariff target |
| `peak_margin_w` (50) | Watts the peak guard aims under `peak_cap_w` (SAFETY-79). Reports and the bill use `peak_cap_w` itself |
| `peak_soc_floor` (20) | **The percent below which the capacity-peak guard will not discharge the battery.** ⚠️ It bounds **the peak guard only** — it is **not a pack-wide reserve**, and ordinary self-consumption discharges straight past it (SAFETY-25, see below). Not optional and not the same thing as `maintenance_soc_floor` |
| `bms_soc_floor` (10) | The pack's **own** cut-out percent, the number the BMS enforces whatever you set above. `peak_soc_floor` must be **strictly above** it or the add-on refuses to start. ⚠️ **At a declared `inverters:` roster this key moves INTO each entry and is REQUIRED there** (SAFETY-32): it describes a battery, and two packs of different models have different cut-outs, so one number for both protects the shallower pack with the deeper pack's BMS. Nothing is inherited — an entry that omits it is refused **by name** at startup, and the flat key below is then not read at all |
| `price_now_entity`, `price_avg_entity` | Dynamic tariff. Empty = never force a paid grid top-up |
@@ -1578,7 +1720,33 @@ help - see "Why the tuning is what it is".
On a capacity-tariff site the maintenance charge is capped by the headroom left
under `peak_cap_w`, and if the forecast goes over the cap the charge-only clamp
is dropped so the battery can shave the peak instead. Money outranks the
maintenance schedule.
maintenance schedule. With one battery or several, the charge also stays
within the room left in the 15-minute period, so a late meter reading does
not let it run at full power.
With two or more batteries, the one being emptied gives its drain rate and the
others only add power when the house needs more; none charges while it drains
(SAFETY-78). Below the drain rate the rest is exported, as with one battery.
If the house would still go over the peak limit, the battery being emptied
gives more than its drain rate, with one battery too (SAFETY-83).
A battery at its peak reserve gives last: the others give their full power
first, and the battery being emptied rises above its drain rate before it
(SAFETY-91).
In a cheap window the battery being filled charges and the others only add
charge; none gives while it charges. The charge is cut to what keeps the
15-minute peak at the limit minus `peak_margin_w` (SAFETY-84).
While a full battery rests after its charge (the hold), it gives just enough
to keep the 15-minute peak at that aim if the house needs it; with two
batteries the other one gives first. The hold still ends on its clock
(SAFETY-86).
When a charge ends, the other batteries take over one slew step a cycle,
and none starts charging from the grid (SAFETY-93).
When a battery's link drops, the others take over one slew step a cycle,
and control does not stall on the dropped battery's power (SAFETY-96).
When a drain ends (done, Off, timeout, abort, lost link, refused), the
other batteries cover the house at once but do not export its drain; then
they move one slew step a cycle (SAFETY-95). While that battery settles,
an old battery reading does not move them (SAFETY-103).
#### Capacity-tariff exposure of the grid-following loop
@@ -1648,10 +1816,17 @@ ceiling at the cap, so a broken instrument makes the guard stricter, never loose
**When it cannot see, it forbids importing.** Three states are not evidence and
are checked before the projection is graded: no open quarter (a fresh averager
projects a confident 0 W, which is under every ceiling there is), a meter gap
longer than `meter_max_age_s`, and SAFETY-18's frozen-meter conjunction. In all
three the claim becomes a floor of **0 W**. That is the backstop for the frozen
meter: the alarm arrives at `meter_freeze_s` (300 s) of a 900 s billing quarter
and commands nothing, and this stops the import.
longer than `meter_max_age_s` while it lasts, and SAFETY-18's frozen-meter
conjunction. In all three the claim becomes a floor of **0 W**. That is the
backstop for the frozen meter: the alarm arrives at `meter_freeze_s` (300 s) of
a 900 s billing quarter and commands nothing, and this stops the import.
**After a gap it goes on (SAFETY-90).** The seconds the meter missed count at
the higher of the peak limit and the import seen just before and just after
the gap, with the batteries at 0 W. Seconds before the add-on's first reading
count the same way, at the import seen first, and the page says part of the
period was not measured. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md has the
bound.
**It trips, where the freeze detector only notifies,** and the captures are why.
On the healthy reference day (2026-08-23) it engages on **zero** of 95 quarters.
@@ -1672,7 +1847,8 @@ control action and goes to the action log and the status page. A *saturated*
guard — asking for everything the inverter has while the quarter is still
projected over — raises one notification (`goodwe_peak_saturated`), because that
is the one state where the money will be spent and shedding load is the only
thing left that changes the bill.
thing left that changes the bill. SAFETY-81 keeps a 1 s meter spike, noise and
a quarter's last seconds from raising it: see `peakguard.load_too_high()`.
**And it sizes a price-driven charge, not only a forced discharge (SAFETY-45).**
The same arithmetic read the other way answers *"how hard may this site charge
@@ -1713,7 +1889,9 @@ exactly like the SoC drift the monthly maintenance cycle exists to correct.
It will discharge straight past this number and keep going until the pack's own
BMS cut-out stops it. What you are promised by `peak_soc_floor: 20` is *"the
capacity-peak guard will not spend the pack for money below 20 %"*, and
**nothing more**. See below for what that costs on a real evening.
**nothing more**. See below for what that costs on a real evening. With two
or more batteries, one under it is used last: only once the others give
their full power (SAFETY-91).
- **When it binds you are told**, once per episode, with notification
`goodwe_peak_soc_floor` and a red status-page row reading *Battery at its
peak reserve* (`PEAK_GUARD_FLOOR_LIMITED` in the log): the quarter **will**
@@ -1858,6 +2036,15 @@ over the rating is logged as a software fault, at `ERROR`, and it has its own
A meter that has died is easy — it stops answering, the sample age climbs past
@@ -2028,20 +2215,24 @@ does, and only after you have read why.
> `static_profile` below needs no network at all, so its cheap window is
> computed on every cycle and reaches the maintenance cycle's grid top-up
> whether or not arbitrage is armed. ⚠️ **And it is still the only source of
> that window.** A provider-backed plan now exists on every configured site,
> but *Cheap window* and the maintenance cycle's grid top-up read
> `static_profile` and nothing else — a deliberate limit, recorded with what it
> would take to change in`DECISIONS/TARIFF-10-fetching-is-not-trading.md`.
> that window, with one exception.** A provider-backed plan exists on every
> configured site, but *Cheap window* and the maintenance cycle's grid top-up
> read`static_profile` and nothing else — a deliberate limit, recorded with
> what it would take to change in
> `DECISIONS/TARIFF-10-fetching-is-not-trading.md`. The exception is
> `price_service` (PRICE-01): with it, the window comes from the provider's own
> prices, as described under [`price_service`](#price_service--your-own-price-server-and-what-it-falls-back-to).
| option | meaning |
|---|---|
| `price_provider` | `off` (default) or one of the three plugins below |
| `price_provider` | `off` (default) or one of the plugins below |
| `price_markup_eur_kwh` | Your supplier's margin, EUR/kWh. **Added only when the chosen plugin's feed does not already contain it** |
| `price_taxes_eur_kwh` | Distribution, levies and VAT, EUR/kWh. Same rule. Defaults to **0.11736** — a real Flemish figure, and **yours is probably different**: see *What `price_taxes_eur_kwh` is made of* below |
| `export_price_eur_kwh` | The **flat injection** price, EUR/kWh. May be negative — see below |
| `price_export_formula` | The **injection formula**, if your contract has one. Same shape as `price_formula`, its own coefficients, its own `vat_pct` — see below |
| `price_csv_path` | Where `manual_csv` reads its file |
| `price_feed_url` | Override the plugin's default feed. Used **exactly as written** — the add-on appends nothing to it, including the date range, so an override gets whatever horizon that URL returns. Only a host the plugin itself declares is accepted |
| `price_service_token` | The token for `price_service`. A password field. Empty with any other source |
| `price_horizon_h` | How far ahead to ask for, hours |
| `price_timeout_s` | Per-request timeout |
| `static_profile` | A static day/night or fully-fixed tariff. Empty by default — see below |
@@ -2054,6 +2245,7 @@ arbitrage decision wrong by that amount, in a direction nothing reports.
| plugin | product | the published figure contains | the add-on adds |
|---|---|---|---|
| `generic_dayahead` | day-ahead | energy only (wholesale EPEX BE) | markup **and** taxes |
| `price_service` | day-ahead | energy only (wholesale, from your own price server) | markup **and** taxes |
| `custom_formula` | day-ahead | energy **and** your contract's markup — your card's `Tariefformule` line | taxes |
The host is fixed in the add-on and only HTTPS is used. The token goes in
`price_service_token` and is sent as `Authorization: Bearer <token>`. The server
answers the energy-charts layout, so the same parser reads it. The price is the
wholesale energy price and nothing else, so the add-on adds your markup and
taxes exactly as for `generic_dayahead`.
**Where the prices come from.** Each step is used only if it has a price for
now. A server that answers with last night's prices is treated as down.
| Step | Source | When it is used | What the log says (once per change) |
|---|---|---|---|
| 1 | The price server | It answers, with a price for now | `The price service answers again.` on the way back. |
| 2 | energy-charts.info | Step 1 fails: down, timeout, refused token (401), error (5xx), a damaged answer, or no price for now | `The price service does not answer, so prices come from energy-charts.` Or `The price service refused the token, so prices come from energy-charts.` |
| 3 | The prices saved in `/data/price_history.json` | Steps 1 and 2 fail | `No price source answers, so the add-on uses the prices it saved.` |
| none | Nothing | No saved price covers now either | `No price source answers, and no saved price covers now.` |
The saved prices are the last answers that worked, kept on disk, so a site
whose server and energy-charts are both down for a day goes on planning from
what it has. It keeps the days the history holds (today, tomorrow once it was
fetched, and a day back). They are the all-in prices as stored: a change of
markup or taxes shows from the next fetch that works. Going back up the chain
is logged once as well: `Prices come from energy-charts again.` and `The price
service answers again.` The refresh runs every 30 minutes.
**When there is no price for now (step none).** One status line, `Prices: No
prices since 00:00, maintenance waits.` (on the add-on page; the Home screen says
the same in English and Dutch), and one notification, *No prices*. Both go when a
source has a price for now again. They show only while **Run the monthly battery cycle**
(`maintenance_enabled`) is on; with it off, neither is shown. "Since" is the moment the last price ran out.
Before the first refresh has finished there is no line, so a start-up is not a
gap. Control is not touched: the battery follows the meter as ever, battery
modes and trading read what prices there are, and only the maintenance charge
waits.
**The maintenance charge and the cheap window.** With this provider the
maintenance charge gate reads the provider's prices and no Home Assistant
entity. It keeps the rule the Home Assistant pair gave: the charge may run
when the **current 15-minute price is at or below today's average**, today
being the Brussels day. Moving a site from the pair to `price_service` does not
change when the charge runs. Where the two can differ is listed in the decision
record: the Home Assistant average was rounded to 0.00001 EUR/kWh, and so is
this one before it is compared. With no price for now the gate is shut, as it
was when an entity was unavailable. *Cheap window* on the status page shows this
answer. This is not the *cheap hours* rule of battery modes and not
`cheap_now()`.
**Moving a site from the Home Assistant price sensors to `price_service`.**
Do this on the Configuration tab, in one save, and restart once:
1. Set **Dynamic price source** (`price_provider`) to `price_service`.
2. Paste the token into **Price service token** (`price_service_token`).
3. **Clear****Current price entity** (`price_now_entity`) and **Average price
entity** (`price_avg_entity`). The add-on refuses to start with a price
source and these two together.
4. Check **Supplier markup** and **Distribution, levies and VAT**. With the
Home Assistant pair they decided nothing about the maintenance charge. With
the provider they are added to the wholesale price, so they set the prices
shown on the page and, if battery modes or trading are on, the prices those
decide on. The maintenance charge gate does not depend on them.
5. Keep **Fixed or day/night tariff** (`static_profile`) if you have one; it
is fine to leave it set. It is the plan's last fallback: it is used,
marked as estimated and without trading, only when no source has a price.
*Cheap window* and the maintenance charge never read it: the provider's
prices decide them. The add-on logs one INFO line at start ("Fixed tariff
is only used if no prices are available.") and shows the same note beside
the setting. Nothing needs clearing, and clearing it only removes the
fallback (the settings page then warns that the site has no tariff while the
price feed is down).
6. Remove the `price_service` REST and template sensors from Home Assistant
when you are satisfied. They are no longer read.
To go back: put the two entities back, set the source to `off`, and restart.
#### So what should a Belgian dynamic-tariff customer do today?
**Honestly: `generic_dayahead` gets you close, and you should know exactly how
@@ -2639,6 +2911,9 @@ uses the result as a cheap-window hint for the maintenance charge. They are
— configure two of them and the add-on refuses to start, naming the conflict,
because the add-on reads exactly one and the loser is silent. Use one.
To move a site off them onto the owner's price server, see [`price_service`](#price_service--your-own-price-server-and-what-it-falls-back-to):
it lists which options to set and which to clear.
### The three buckets — which price components can move a decision
*For installers: card TARIFF-17.*
@@ -2853,10 +3128,17 @@ second set of 23- and 25-hour-day bugs.
### Static day/night and fully-fixed tariffs (`static_profile`)
Most Belgian households are **not** on a dynamic contract, and an EMS that only
works under hourly pricing is an EMS for a minority. `static_profile` is how a
works under dynamic pricing is an EMS for a minority. `static_profile` is how a
two-period day/night tariff or a single fixed price becomes a first-class
configuration rather than "turn the price feature off and hope".
On the add-on page, choose **Other time windows** under Settings, Tariff and
prices, or in Setup step 4. Add one row per time window, with its start, end,
days and price. The page names any overlap, gap or empty price before you can
save. Prices take five decimals: divide the c€/kWh on your bill by 100, so
34.512 c€/kWh is 0.34512 €/kWh. You only need the JSON below for days the page
cannot choose, such as Monday and Wednesday only.
It is one option, holding a JSON object, on one line:
```json
@@ -2996,6 +3278,165 @@ row is printed **always**, including when it is zero: a row that reports
staleness only once it is stale cannot be told from one that never reports
it.
### Car charger
The add-on can drive your car charger and shows it on **Home**, on a *Car* card.
The card has three modes in this version: **Off** (the add-on only reads the
charger and writes nothing), **Manual** (the add-on sets the current and the
phases you choose) and **Solar** (the car charges only from spare sun). Night
mode comes in a later version.
| option | meaning |
|---|---|
| `ev_charger` | `off` (the default: nothing changes at all) or `alfen_ha`, an Alfen charger through its Home Assistant integration. |
| `ev_current_entity` | The charger's current setting, for example `number.wallbox_power_connector_max_current_socket_1`. The add-on finds the charger's other entities from this name. |
| `ev_max_a` | The most current the charger may ever be asked for. It cannot be higher than the station limit the charger reports. |
| `ev_phases` | `1`, `3` or `auto` (1 and 3). |
| `ev_batt_cover` | On (the default): the batteries help cover the car down to the peak reserve. Off: the car is left out of what the peak guard protects. |
| `ev_mode_start` | `keep` (the default) or `off`: the mode after a restart. |
| `ev_margin_w` | Solar: the spare sun never given to the car, 0 to 1000 W (100). |
| `ev_start_min` | Solar: minutes of enough sun before the car starts, 1 to 30 (2). |
| `ev_pause_min` | Solar: minutes the car holds 6 A on too little sun before it pauses, 1 to 30 (5). |
**What the Car card shows.** The state (Charging, Connected waiting, No car
connected, Car is full, Charger not reachable), the power and current, and the
energy charged today. The car's power is taken out of the **House** tile and out
of the house profile that plans the batteries' night charge, so the batteries
no longer buy energy for a car that charged last night.
**Manual mode.** Choose *Manual* on Home, then set the current (6 A up to the
charger limit) and 1 or 3 phases. The same three are Home Assistant entities
when MQTT is on: `select.goodwe_car_mode` (Off, Manual, Solar), `number.goodwe_car_current`
and `select.goodwe_car_phases`. The mode, the current and the phases apply at
once, with no restart. The add-on writes each one once, when you change it, and
checks within 10 seconds that the charger took it.
- The current is never higher than the smallest of the charger limit, the station
limit the charger reports and the charger's own range. A value above that is a
software fault: it is logged and never sent.
- With no car connected, or a full car, nothing is written. The setting waits
until a car is connected.
- A phase change always goes through the same steps: 0 A, wait until the
charger draws under 100 W (at most 20 seconds), select the phases, wait 10
seconds, set the current again. At most one phase change per 10 minutes.
- Shadow mode keeps the charger alone, as it keeps the inverters alone: the card
says what the add-on *would* set. Nothing is written either while control is
stopped.
- A restart, stopping control and a safety stop leave the charger at its
current. When the charger answers again after being away, the add-on sets your
current again only if the charger shows a different one.
- Off writes nothing, ever.
**Solar mode.** Choose *Solar* on Home, or `Solar` in `select.goodwe_car_mode`.
The car charges only from the spare sun: what the solar panels make that the
house does not use (the meter, the batteries and the car's own power add up to
it). *Spare sun goes first to* (on the card, and `select.goodwe_car_sun_first`)
says who gets it first:
- **Batteries:** the car gets the sun the batteries cannot take. Each battery
that may charge from the sun (switched On, not refusing a charge, not full)
keeps its whole rating first. With your two batteries and one of them full,
7.9 kW of sun and 0.9 kW of house leave 1.9 kW for the car: 8 A on 1 phase.
- **Car:** the car takes the spare sun first, the batteries get the rest.
In both, `ev_margin_w` (100 W) is kept back. The current is the car's share
divided by 230 V per phase, rounded down, from 6 A up to the charger limit. It
changes at most once per 30 seconds and only by 1 A or more.
- **Start and pause.** The car starts after `ev_start_min` (2 minutes) with
enough sun for 7 A. Under 6 A worth it holds 6 A for `ev_pause_min` (5
minutes), from the batteries or the grid, then the charger goes to 0 A and
the card says *Waiting for sun*.
- **Phases** (`ev_phases` auto): Solar starts on 1 phase, goes to 3 at 4.5 kW for
3 minutes and back to 1 under 4.0 kW for 5 minutes, at most once per 10
minutes, always through the safe sequence above. With `ev_phases` 1 or 3 it
never switches. A car that draws one phase while three are allowed is counted
on one phase until it is unplugged.
- **When the sun cannot be measured** (the meter older than 15 seconds, a battery
or grid reading missing, readings late, a car reading that is stale or not
confirmed by the charger's energy meter), the current stands for
`ev_pause_min`, then 0 A.
- **The fail state is 0 A.** Choosing Off, stopping control, shadow mode, a
safety stop, a charger error, a stuck charger reading, unplugging the car and
stopping the add-on each set the charger to 0 A once. A 0 A the charger does
not take is tried again after a minute, three times, then an amber row says
so. After a restart, or when the charger or Home Assistant answers again,
Solar sets 0 A first and then starts by its own rules. At a stop of the
add-on the charger's 0 A goes out before the batteries go to 0 W, for at
most 15 seconds; if the charger does not take it, the notice *Car may still
be charging* follows.
- **Shadow mode** writes nothing but that one 0 A; a start in shadow mode writes
nothing at all. The card says what Solar would set.
- **Another writer.** If the charger shows a current Solar did not set for 30
seconds, Solar writes nothing over it (also no 0 A), shows an amber row and
logs one warning, until you press Solar again or the charger shows Solar's
value.
- **The peak limit** treats a Solar car exactly as a Manual car (below). Solar
does not slow the car for the peak in this version.
- **Energy.** The card says "{kWh} charged today, {kWh} from the sun", and the
sensor `goodwe_car_today_solar_kwh` has the sun's part. Only Solar's own
share of spare sun counts, not the hold's battery or grid power.
**The car is never slowed for the peak limit.** A Manual charge goes on whatever
the 15-minute peak does. With the default `ev_batt_cover` on, the batteries help
cover it down to the peak reserve; a 3-phase 16 A charge (11 kW) can empty two
batteries to the reserve in about 1.5 hours, and the month's peak then rises by
what the car drew. When the car alone is why the batteries cannot hold the
period, the add-on does **not** raise *Battery stopped limiting the peak* or
*Load too high for battery*. It shows a grey note *Car over the peak
limit* once per charging session, a grey row, and says so in the car's *Why*.
This holds only while the car's reading is fresh and the charger's energy
meter confirms it (the meter must have gained at least half of what the power
adds up to over the last minute). A stale, stuck or frozen reading, or a
charger with no energy entity, never hides a real overload of the house: the
normal alarms stand. With `ev_batt_cover` off, the peak
guard protects the house without the car, so it does not spend the batteries on
it. Normal zero-grid control can still discharge them for the car, and a grid
charge of the batteries can bring the period to the peak limit plus the car.
The period can go over by the car alone. When the month's peak was set by a car
charge, Home's peak line says so.
**When the charger does not answer.** After 30 seconds the card says *Charger
not reachable* and one amber row appears. After 5 minutes one notification
follows. While the car reading is older than 15 seconds the House tile shows no
reading, and that moment is left out of the house profile, rather than guessing
how much the car took. A reading that does not move for a minute after the
add-on changed the current shows the amber row *Charger reading may be stuck*;
the add-on goes on writing. If the charger does not take a phase change three
times, an amber row says so and the add-on stops trying until you change
something; the car gets its current back each time.
**Another writer.** In Manual, if the charger shows a different current than the
add-on set, for 30 seconds, something else is setting it, usually your own
automation. The page shows a grey row, and the add-on writes nothing over it until
you change the mode or a value. In Off the grey row *Something else changes the
charger* shows for an hour after a change. That is expected while you migrate.
**Moving your own automation to the add-on.** Each step can be undone.
1. Install this version and set `ev_charger` to `alfen_ha`. The mode starts in
**Off**: the add-on reads the charger and writes nothing. Compare the card
with your automation for a few days.
2. Cut-over, in the evening with the car unplugged: in Home Assistant switch your
automation **off** (do not delete it). On the card choose **Manual** with the
current your helper held (`input_number.ev_manual_current`). Plug in and check
the current on the card and on the charger's display.
3. On the next sunny day, choose Solar, with *spare sun goes first to* set as
your priority switch was.
4. Keep your Home Assistant helpers for a week. To go back, set the add-on mode
to Off and switch the automation on. After that you can delete the helpers and
the automation.
**Never let the automation and the add-on both write the charger.** Two writers
fight over the one setting and neither can tell which won. Turn the automation
off before you choose Manual, and the add-on off (mode Off) before you turn the
automation on.
**Home Assistant entities.** With MQTT the add-on adds the sensors
`goodwe_car_power`, `goodwe_car_state`, `goodwe_car_today_kwh` and
`goodwe_car_today_solar_kwh`, and the four controls named above. A saved ("retained") command is never applied, so a
restart of Home Assistant cannot change the charger.
### Site
| option | meaning |
@@ -3021,7 +3462,10 @@ The battery gives less power than the add-on asks for. This is normal for a
short time, for example just after a large load switches on or the sun comes
out. It is not a fault, and control keeps running. If it keeps coming back,
check that the battery is switched on, and that it is not empty (when it should
give power) or full (when it should charge).
give power) or full (when it should charge). During the monthly maintenance or
while the peak limit is guarded, it only shows when the battery gives
clearly less than it was told. The status page counts how many times it
happened.
### Power request too high
@@ -3056,6 +3500,10 @@ and what to do:
- **A battery cut-out level is not known.** Fill in “Battery cut-out level”
for each inverter in the settings.
With several inverters, a battery at its peak reserve does not give for the
peak and the others do. This alarm then comes only when the others cannot
keep the period under the limit alone. Control keeps running meanwhile.
The peak reserve only applies to keeping the peak down. Normal home use can
still draw the battery below it, down to the battery cut-out level, where the
battery switches itself off.
@@ -3091,12 +3539,68 @@ reading is stuck. Control keeps running and keeps following the reading, so a
stuck reading can raise this month's peak. Check the meter. If it is stuck,
stop control on the add-on page.
### Battery cycle did not finish
The monthly battery cycle stopped because the battery did not empty, or did not
fill up, in time. The battery is back under normal control. The add-on waits 7
days before it tries again, so it does not empty the battery every night. To
try sooner, start a cycle on the add-on page. If it keeps happening, check that
the battery follows its commands and that the cheap hours leave time to charge.
### No prices
No price source has a price for the present moment: not the price server,
not energy-charts, and nothing saved. The monthly battery cycle waits, because
it will not charge from the grid without a price to judge by. Control of the
battery goes on as before. Check that the add-on can reach the internet and that
the price service token is right. The notification goes by itself when a price
is back. It is shown only while the monthly battery cycle is switched on.
### Charger not reachable
The add-on has not been able to read the car charger for 5 minutes, because its
entities are unavailable or the charger's login is off. The charger keeps its
last setting. The add-on changes nothing on the charger in any case. Check the
charger's integration in Home Assistant. The notification goes by itself when
the charger answers again.
### Car over the peak limit
The car charge you set (Manual) takes the 15-minute period over the peak limit,
and the batteries cannot hold it because they are at the peak reserve or at
their full power. The add-on never slows the car, so this is information, not an
alarm. It is raised once per charging session. To stay under the limit, lower the
current. In Solar it says "Solar charges the car at {a} A, which sets the
peak.": the same case, with the current the charger has.
### Charger kept its current
The add-on started without writing to the charger (shadow mode, or control
not started yet), and the charger still has the current the add-on set before
it stopped, in Manual or Solar. Nothing changes the charger until you start
control or turn shadow mode off. Check the charger if the car should not be
charging. The notification goes once the charger shows 0 A.
### Car may still be charging
The add-on stopped in Solar mode, and the charger did not take the 0 A it sent
first. The batteries were set to 0 W on time anyway. Check the current at the
charger. At the next start Solar sets 0 A first and the notification goes.
### For installers: notifications
A fixed tariff beside the price service raises no notification: it is the
plan's last fallback, not a fault. An earlier pre-release build raised a card
with the id `goodwe_fixed_tariff_unused`; the add-on takes that id down at every
start, which does nothing when it is absent.
This part is for installers. The texts live in `app/messages.py` and follow
`STYLE.md`. Every notification keeps a fixed `notification_id`, so a repeat
replaces the card. The full figures and reason codes are on the ERROR or
WARNING line of the add-on log.
replaces the card. The ERROR or WARNING line of the add-on log names the
reason code. The full figures are in `events` in the `status` JSON, also for a
stop restored after a restart, and on the DEBUG line logged right after it.
That DEBUG line only shows with “Log level” (log_level) set to `debug`; the
default `info` hides it.
| Title | Severity | id | Card |
|---|---|---|---|
@@ -3107,6 +3611,10 @@ WARNING line of the add-on log.
| Inverters working against each other | alarm | `goodwe_circulating_power` | SAFETY-31 |
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` | SAFETY-42 |
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` | SAFETY-18 |
| Battery cycle did not finish | warning | `goodwe_maint_failed_<name>` | MAINT-13 |
| No prices | warning | `goodwe_no_prices` | PRICE-01 |
**Load too high for battery.** The capacity-peak guard (SAFETY-07) asks for
everything the inverter can discharge and the running 15-minute average is
still projected over the peak limit, so the month's billed peak
(capaciteitstarief) goes up. In shadow mode the guard's projection is made on a
plant that did not respond (SAFETY-47), and the text says so. See *The
capacity-peak guard*.
(capaciteitstarief) goes up. It fires only when, for 10 s, the period would
still end more than 10 W over the real limit (not the margin's aim) with the
battery at full power. It notifies at most once per period; later overloads
in the same period go to the log (SAFETY-81). In shadow mode the
guard's projection is made on a plant that did not respond (SAFETY-47), and
the text says so. See *The capacity-peak guard*.
**Battery stopped limiting the peak.** The peak guard may not discharge below
`peak_soc_floor` (label “Peak reserve”, SAFETY-24). It also stops when the
@@ -3145,7 +3657,9 @@ state of charge is unread, or when an inverter's `bms_soc_floor` (label
“Battery cut-out level”) is missing, because the reserve is graded against it.
Charging from the grid stays blocked meanwhile. With several inverters the
notification names the battery at its limit (SAFETY-32), each graded against
its own cut-out level. ⚠️ **The reserve binds the peak guard only
its own cut-out level. That battery is held (weight 0 while the site gives)
and the guard's need goes to the others, up to their rating; the alarm fires
only if they miss the limit at full power for `ALARM_HOLD_S` (SAFETY-87). With no battery able to give it fires at once, but only if the period would end more than 10 W over the aim with the batteries at 0 W. A grid charge the add-on runs counts as one it can stop, and the last second's landing error on the aim is not an alarm. A steadily rising load therefore alarms a little later. With `peak_margin_w` 0 a period can end up to 10 W over the limit without this alarm, as for “Load too high” (SAFETY-126). ⚠️ **The reserve binds the peak guard only
(SAFETY-25).** Self-consumption has no such floor. See *What `peak_soc_floor`
does not protect*.
@@ -3189,6 +3703,95 @@ action log (`Controller.events`). The page no longer shows that log, but the
page and add `status` to its address. The action-log tables in this document
refer to it.*
### Language and screenshots
The page is in Dutch when your browser's language is Dutch, and in English
otherwise. Status lines, alarms and the start checks' messages stay in English.
Screenshots of each screen are in the add-on's repository, under
`docs/img/ux13/`, including the Batteries screen and Settings, Simple.
*For installers: regenerate the screenshots with
`tools/ux13_screenshots.sh`, which serves the page from test fixtures.*
### The Batteries screen and Settings, Simple
The **Batteries** tab has a card per battery: its level, and three lines.
**Now** says what it does, **Today** lists the blocks planned for it (price
trades, the monthly cycle, the peak limit), and **Why** says the reason. With
battery modes on, each card also has the On/Off switch and the mode list; both
apply at once. Today reads "Not planned yet" until the add-on has made the
day's price runs.
An Off battery that the peak limit still needs says so, with the power it
gives: "Off, but gives 0.5 kW for the peak limit."
With two or more batteries, each card also has **Start cycle** and **Stop
cycle**, to run the monthly cycle on that battery now. Only one battery cycles
at a time: a start while another battery is cycling, or on a battery that is
switched off, is refused and the message names the battery.
**Settings** opens on the **Simple** view, or on the view you last picked:
the peak limit, the batteries' switches and modes, and shadow mode, each
marked "Applies right away" or "Applies after a restart". **Installer** shows
every setting.
### The Forecast screen
The **Forecast** tab shows today and tomorrow, hour by hour: the solar forecast,
the solar measured so far today, the house's expected use, and each battery's
expected level. Under each battery's chart are its planned blocks, in the same
words as Home. A block is there only where the add-on plans one.
The level is an estimate. It counts on `solar_trust_pct` of the forecast, as the
plan does, and stays between the battery's low and high levels. A forecast that
gives one total for the day (Forecast.Solar) is spread over the hours, and the
screen says so. Where a part is not known yet (battery modes off, no forecast,
still learning your house, no forecast for tomorrow) the screen says that
instead of drawing an empty chart. It changes nothing in control, and it asks
Home Assistant for nothing: it is built when you open it.
### Setup, for a new install
The **Setup** tab walks an installer through six steps: the meter, the
inverters and batteries, solar (optional), prices, the peak limit, and a last
check. Each step shows the same fields as Settings, and nothing is saved until
the last step.
- **The kettle test** on the meter step reads the meter, then reads it again
after you switch on a kettle. If the reading goes down, the add-on flips its
sign for you; with a net or import/export meter it tells you what to change.
- **The last step** runs the add-on's own start checks and reads Home
Assistant: the meter reading, that each power request entity exists, the
battery levels, and whether prices are known. A missing power request or
meter entity is red, so it cannot be saved.
- **Save and restart** saves, then restarts the add-on. Every inverter is set
to 0 W while it restarts, and with "Start in shadow mode" on (the default) it
stays at 0 W until you turn shadow mode off under Settings.
Setup opens by itself on a new install's first start, until Setup finishes or
control is started, and whenever the stored settings name no inverter to
control. A site that already ran before is never sent there.
A new install names no inverter yet, so the add-on starts **in setup**: it
serves the page and sends nothing to any inverter. Home says "Setup: nothing
is controlled yet", and there is no Start button. The installer's steps:
1. Install the add-on, turn on **Watchdog** on its Info tab, and start it.
Leave the Configuration tab as it is.
2. Open the add-on's page. Setup opens by itself.
3. Go through the six steps and press **Save and restart**. With "Start in
shadow mode" on, every inverter stays at 0 W after the restart.
4. On Home, check the meter direction and what the add-on would do. Turn
shadow mode off under Settings when it looks right.
Any other problem in the stored settings still stops the add-on (exit code 78),
and the log names each one. Fix those on the Configuration tab.
*For installers: cards UX-13 and UX-15, `DECISIONS/UX-13-setup-wizard.md` and
`DECISIONS/UX-15-setup-only-mode.md`. In setup the `status` JSON has
`setup_only: true`, and no MQTT entity is published.*
## Status page
The add-on page shows a banner at the top and a **Commissioning** list below
@@ -3202,15 +3805,20 @@ inverter stays at 0 W. If the banner is red and says a safety stop stays on,
one of the red rows below is a stop that will still be there when shadow mode
ends. That row says how to clear it.
In **setup** (a new install that names no inverter yet) the banner says
nothing is controlled yet, and the one row says to finish Setup. See *Setup,
for a new install*.
| Row starts with | What it tells you |
|---|---|
| Home Assistant is not answering | Home Assistant is not passing readings or power requests on, usually because it is still starting. The add-on cannot control until then. It resumes by itself. Nothing to do unless it lasts. |
| Control | When control last ran. Red when it has stopped running: the control board then sets the inverter to 0 W. |
| Meter | The grid reading, its age, how many readings were refused, and how long its value has not changed. Just after a start it is amber and *waiting for the first reading*. Red means no reading for longer than the limit. |
| Stuck-meter check | Whether the add-on can warn you about a stuck meter. |
| Meter reading may be stuck | See *Meter reading may be stuck* under Notifications. |
| Month peak | This month's highest 15-minute average, when it happened, and how close it is to your peak limit. Amber from 80 %. |
| 15-minute periods measured this month | How many 15-minute periods the add-on has measured and saved this month. |
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. |
| Peak guard, Load too high for battery, Battery at its peak reserve | What the add-on does to keep your peak down. *Idle, heading for …* is where this 15-minute period is heading. *At this rate … over …* means it would go over at the current rate. With *grid charge limited*, a charge from the grid is cut back so it does not. *Waiting for meter readings* after a restart means the battery does not charge until the add-on can measure the period again. A red peak row is an alarm while control keeps running, so the banner shows its title without *Not ready*. |
| Battery level, Battery power, Grid power | The reading of that entity. *No usable reading* means the entity is missing, or its reading is too old. Check it in Developer Tools before replacing it. |
| Inverter control | Whether the inverter can be controlled, and how much it can charge and give. |
| *name*: battery power reading stopped changing | The reading did not change while the add-on asked for a change. It may be stuck, or the battery may be refusing. The add-on sets the inverters to 0 W until it changes. |
@@ -3219,12 +3827,14 @@ ends. That row says how to clear it.
| Direction check, Site direction check | Whether each inverter's power goes the way the add-on asks. *Opposite for 12 of 60 seconds* counts toward a stop. When it stops, the inverter, or every inverter, is set to 0 W until you start control. |
| Check for inverters working against each other, Inverters worked against each other | Only with several inverters. See *Inverters working against each other*. |
| Delivery check, *name* is not delivering | Only with several inverters. See *An inverter is not delivering*. |
| Prices | Only while no price source has a price for now: *No prices since 00:00, maintenance waits.* See *No prices* under Notifications. |
| Solar production | Your solar production. Sources are numbered in the order of “Solar production entities, per inverter”. A strongly negative reading by day means that entity reads the wrong way round: add it to “Reversed-sign solar entities”. |
### For installers: status page
The texts are in `app/messages.py`. The full figures of any alarm are on its
ERROR or WARNING line in the add-on log.
The texts are in `app/messages.py`. An alarm's ERROR or WARNING line names its
reason code, and its full figures are on the DEBUG line right after it and in