OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
checks / unit (pull_request) Successful in 11m4s
infra-pin / fresh (pull_request) Successful in 2s

- arbiter: a mode now gives way only as far as a site limit above P_MODE
  needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
  released only when the peak floor bound S, so a trade won above the floor
  kept them and placed less than the floor (an Off battery at N=1 went to 0 W
  under a 2000 W floor), and a capped grid charge released an Off battery.
  While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
  rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
  (peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
  loop bound counts live units only). DOCS and DECISIONS say the new rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
This commit is contained in:
glenn schrooyen
2026-09-28 19:41:36 +02:00
co-authored by Claude Opus 5.5
parent d69fd8fbfd
commit ffc9a4d721
10 changed files with 365 additions and 40 deletions
@@ -1,14 +1,21 @@
# OPT-11 - battery modes, per battery
A battery's mode (on/off, Solar first, Leftover solar) is a soft unit limit at
`P_MODE` = 35 that always holds 0 W, applies only while the site target is
decided at or below 35, and is released by anything above it, such as the peak
guard. Design and owner answers: `goodwe-session/OPT-11-design.md` (2026-09-27);
`P_MODE` = 35 that always holds 0 W. A SET above 35 (a safety stop) overrides
it; a limit above 35 (the peak guard) makes it give way only as far as that
limit needs, and a battery its mode holds back then carries only what the
others cannot (`arbiter._unit_modes()`, `_site_mode()`). Design and owner answers: `goodwe-session/OPT-11-design.md` (2026-09-27);
P1 is its section 6 P1, and the pull request lists what was measured.
- Off by default (`battery_modes_enabled`); off, commands are byte-identical to
a5dddad (`test_modes.py` part 1).
- Off is a mode range, so the peak guard can still use an Off battery (design
sections 2-3). Whether Off should be absolute is an open owner question.
- Off is a mode range, so the peak guard can still use an Off battery when the
others cannot cover the floor (design sections 2-3). Whether Off should be
absolute is an open owner question.
- Review (PR #149): releasing only when the peak floor bound S let a trade won
above the floor keep the modes and place less than the floor, and let a
capped grid charge release an Off battery. Both are graded in
`test_arbiter.py` part 11. The loop bound leaves a side that reaches the
rail to the rail, so SAFETY-03 still flags a loop winding into it.
- In P1 only Off closes a direction; Leftover solar differs by charging last.
Price runs, selling (`pack_sell`, reserved) and the forecast are P3/P4.
+2 -2
View File
@@ -517,12 +517,12 @@ below.
Off by default. Turn it on, restart the add-on, and the Batteries screen gives each battery two controls. They apply at once, with no restart.
- **On or off.** Off asks the battery for 0 W and starts no monthly cycle on it. A cycle that is running stops, and the add-on log says so. The peak limit may still use it, like every battery.
- **On or off.** Off asks the battery for 0 W and starts no monthly cycle on it. A cycle that is running stops, and the add-on log says so. The peak limit may still use it, but only for what the other batteries cannot cover.
- **Mode.** *Solar first* charges from spare solar before the other batteries. *Leftover solar* charges from the solar they cannot take. Both cover the house at any hour. Charging from the grid in cheap hours, and selling, come in a later update.
The peak limit, the safety stops and the monthly cycle always come before a battery's mode.
*For installers:* a mode is a limit at priority 35, kept apart from the hard limits, and released whenever a claim above it (the peak guard) decides the site target. A mode range always holds 0 W, so a mode can forbid a direction and never force one. With one inverter the mode also bounds the loop. The record is `DECISIONS/OPT-11-battery-modes.md`.
*For installers:* a mode is a limit at priority 35, kept apart from the hard limits. It gives way only as far as a limit above it (the peak guard) needs. A mode range always holds 0 W, so a mode can forbid a direction and never force one. With one inverter the mode also bounds the loop. The record is `DECISIONS/OPT-11-battery-modes.md`.
### Reading the grid-following loop: `Loop integrator`, `Loop integrator lead`, `Loop reason`
+3 -3
View File
@@ -304,9 +304,9 @@ def unit_interval(b, deciding_priority=None):
"""OPT-11. `(lo, hi, note)`: the interval a unit is allocated into.
The hard limits (`b.lo`, `b.hi`) always apply. The unit's MODE range
(`b.mode_lo`, `b.mode_hi`) narrows them only when the site target was
decided at or below the mode's own priority - `deciding_priority` None
means no higher claim was named, so the mode applies. `note` says why the
(`b.mode_lo`, `b.mode_hi`) narrows them unless `deciding_priority` is
above the mode's own priority (arbiter._unit_modes() passes None when the
modes hold, and the yielding limit's priority when they give way). `note` says why the
mode did not apply, or is None when it did or there is none:
* MODE_FAULT: the mode range leaves out 0 W. A mode may forbid a direction
+108 -20
View File
@@ -87,9 +87,9 @@ P_MAINT_SHAPE = 40 # maintenance shaping the loop (charge-only)
# loop would otherwise cancel every charge the moment it created import.
P_ARBITRAGE = 30 # price arbitrage - trades against the meter on purpose
# OPT-11. A battery's mode (Solar first, Leftover solar, Off): a SOFT unit
# limit, kept apart from the hard ones and applied only while the site target
# is decided at or below this priority. Above arbitrage, so a trade stays inside
# each battery's mode; below the peak guard, which releases every mode.
# limit, kept apart from the hard ones. Above arbitrage, so a trade stays inside
# each battery's mode; below the peak guard, to which a mode gives way only as
# far as the floor needs (`_unit_modes()`, `_site_mode()`).
# DECISIONS/OPT-11-battery-modes.md.
P_MODE = 35
P_LOOP = 10 # ordinary grid-following
@@ -250,8 +250,8 @@ CLAIM_SCOPE = {
# main.py: `Claim.limit("mode", P_MODE, lo, hi, ...)`, OPT-11. THIS
# battery's mode, chosen per battery by its owner. A unit claim that never
# enters a `lo > hi` test with a site limit: stage 1 keeps it apart from the
# hard limits, and stage 3 applies it only when the site target was decided
# at or below P_MODE. At N=1 it routes to the site like every source, and
# hard limits, and it gives way to a site limit above P_MODE only as far as
# that limit needs (`_unit_modes()`). At N=1 it routes to the site, and
# `resolve()` takes it out of stage 2 for the same reason.
"mode": SCOPE_UNIT,
}
@@ -434,9 +434,10 @@ class Resolution:
# `explain()` names.
winner_priority: int | None = None
# OPT-11. The higher of the winning set's priority and the priority of the
# limit that bound `target_w`. Stage 3 applies each unit's mode only when
# this is at or below that mode's priority (P_MODE), so a peak floor that
# binds S (P_PEAK) releases every mode and never meets a mode `hi`.
# limit that bound `target_w`. Whether the modes hold is decided from the
# limits themselves (`_site_mode()`, `_unit_modes()`): a mode gives way
# only as far as a limit above it (the peak floor) needs, so a mode `hi`
# never meets a site `lo`.
deciding_priority: int | None = None
# OPT-11 at N=1: why the site's mode layer was dropped this tick, or None.
# At N>1 the same fact is on `allocation.mode_faults`, per unit.
@@ -676,7 +677,7 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
# `claims`, so this is the shipped arbiter on the shipped list.
out = site_resolve(site_claims)
if site_modes:
_site_mode(out, site_modes)
_site_mode(out, site_modes, site_claims)
# STAGE 3 - the seam, and since ALLOC-01 the allocator behind it.
#
@@ -709,23 +710,67 @@ def resolve(claims: list, *, units=None, weights=None, live=None,
# nothing. See `packshare.weights()` on the residual this leaves (the fill's
# own direction can differ from the target's sign under a pin, in which case
# the weighting is a worse preference and still cannot be unsafe).
# OPT-11: whether each unit's mode holds this tick (`_unit_modes()`).
# Before the weights, because a limit above the modes may move the target.
gate, held = _unit_modes(out, site_claims, bounds, live)
if callable(weights):
weights = weights(out.target_w)
if held:
weights = {u: (0.0 if u in held else
(1.0 if weights is None else weights.get(u, 1.0)))
for u in bounds}
out.shares, out.allocated, out.allocation = allocate_record(
out.target_w, bounds, weights=weights, live=live,
scope_errors=out.scope_errors, site_priority=out.winner_priority,
tick=tick, deciding_priority=out.deciding_priority)
tick=tick, deciding_priority=gate)
return out
def _site_mode(out: Resolution, modes: list) -> None:
def _limits_above(site_claims: list, prio: int) -> tuple:
"""OPT-11: `(lo, lo_src, hi, hi_src)` over the site LIMITs above `prio`.
These are what a mode may never take the site target outside of: the peak
guard (P_PEAK), maintenance shaping (P_MAINT_SHAPE) and the hard limits.
"""
lo, hi = -inf, inf
lo_src = hi_src = None
for c in site_claims:
if c.kind != LIMIT or c.priority <= prio:
continue
if c.lo > lo:
lo, lo_src = c.lo, c
if c.hi < hi:
hi, hi_src = c.hi, c
return lo, lo_src, hi, hi_src
def _yield_to(out: Resolution, t1: float, above: tuple):
"""OPT-11: the target `t1` the modes allow, moved only as far as the limits
above the mode need (`_limits_above()`). Returns the claim that moved it,
or None when `t1` already satisfies them, and sets `out.target_w`."""
lo, lo_src, hi, hi_src = above
t2 = max(lo, min(hi, t1))
out.target_w = float(t2)
if t2 == t1:
return None
binder = lo_src if t2 == lo else hi_src
out.bound_by = (f"{binder.source}({binder.reason})" if binder.reason
else binder.source)
out.deciding_priority = max(out.deciding_priority or binder.priority,
binder.priority)
return binder
def _site_mode(out: Resolution, modes: list, site_claims: list) -> None:
"""OPT-11 at N=1: the one battery's mode bounds the SITE target, after stage 2.
The unit rule of `allocator.unit_interval()` on the site: the mode applies
only when stage 2 decided at or below its priority, and a range without 0 W
is a software fault that drops the mode (`out.mode_fault`). A clamp of one
number into a range that holds 0 cannot contradict anything, so the peak
floor still wins by releasing the mode, as at N>1.
A SET above the mode (a safety stop) decides alone. Otherwise the target is
clamped into the mode range and then back into the site limits above the
mode, so the mode gives way only as far as those limits need: a peak floor
of 2000 W over an Off battery asks it for 2000 W, whether a trade or the
loop won stage 2, and a charge the peak guard merely caps stays at 0 W. A
range without 0 W is a software fault that drops the mode
(`out.mode_fault`). Clamping one number cannot contradict anything.
"""
out.considered = out.considered + [f"{c.source}:{c.kind}" for c in modes]
lims = [c for c in modes if c.kind == LIMIT]
@@ -737,10 +782,53 @@ def _site_mode(out: Resolution, modes: list) -> None:
if not (lo <= 0.0 <= hi):
out.mode_fault = f"mode range [{lo:.0f}, {hi:.0f}] leaves out 0 W"
return
if out.deciding_priority is not None and out.deciding_priority > prio:
if out.winner_priority is not None and out.winner_priority > prio:
return
target = max(lo, min(hi, out.target_w))
if target != out.target_w:
before = out.target_w
t1 = max(lo, min(hi, before))
if _yield_to(out, t1, _limits_above(site_claims, prio)) is None \
and t1 != before:
c = lims[0]
out.bound_by = f"{c.source}({c.reason})" if c.reason else c.source
out.target_w = float(target)
def _unit_modes(out: Resolution, site_claims: list, bounds: dict, live):
"""OPT-11 at N>1: `(gate, held)` for stage 3.
`gate` is the `deciding_priority` handed to the allocator: None applies
every unit's mode, a number above P_MODE releases them. `held` is the set
of units whose mode holds them back in the target's direction; while the
modes are released they weigh 0, so they carry only what the other units
cannot (the allocator's last-resort pass).
The rule matches N=1: a SET above the mode decides alone. Otherwise the
target is clamped into what the units can place with their modes
(`allocator.loop_bound()`) and back into the site limits above the mode.
If that point is still placeable with the modes, they hold and the target
is unchanged (what they cannot place is reported unmet, as before). If a
limit above the mode needs more, the target moves only that far, and the
modes are released for it.
"""
mode_units = [u for u, b in bounds.items()
if getattr(b, "mode_priority", None) is not None]
if not mode_units or out.contradiction:
return out.deciding_priority, set()
prio = min(bounds[u].mode_priority for u in mode_units)
if out.winner_priority is not None and out.winner_priority > prio:
return out.deciding_priority, set()
clo, chi = allocator.loop_bound(bounds, live)
t1 = max(clo, min(chi, out.target_w))
before = out.target_w
binder = _yield_to(out, t1, _limits_above(site_claims, prio))
if binder is None:
out.target_w = float(before)
return None, set()
held = set()
for u in mode_units:
b = bounds[u]
nlo, nhi, note = allocator.unit_interval(b)
if note is not None:
continue
if (nhi < b.hi) if out.target_w > 0 else (nlo > b.lo):
held.add(u)
return binder.priority, held
+11 -3
View File
@@ -17,6 +17,7 @@ exists because its absence produced a specific, observed failure.
"""
import math
from math import inf
from dataclasses import dataclass
# ---------------------------------------------------------------------------
@@ -500,6 +501,14 @@ def compute(
# main.py never builds one: every term of `loop_bound()` holds 0).
if bound is not None and not (bound[0] <= 0.0 <= bound[1]):
bound = None
# ...and a side of it that reaches the rail is left to the rail, so that
# SAFETY-03's `i_clamped` still fires when the loop winds into it. With
# every battery on, the bound IS the rail, and the law is exactly as it was.
if bound is not None:
_rail = min(tuning.max_w, tuning.max_w if tuning.integrator_max_w is None
else tuning.integrator_max_w)
bound = (float(bound[0]) if bound[0] > -_rail else -inf,
float(bound[1]) if bound[1] < _rail else inf)
# --- saturation, WITH the duration term -------------------------------
# Command and actual diverging means the inverter cannot follow - it is at
@@ -603,9 +612,8 @@ def compute(
i_w = max(moved, i_w)
# OPT-11: the integrator does not wind past what the modes let the
# batteries place. Applied BEFORE the integrator bound below, so a loop
# held by a mode reads as `mode-bound` and not as SAFETY-03's winding into
# the rail (`i_clamped`). That bound still bites where it is the tighter.
# batteries place. Only a side tighter than the rail is left in `bound`
# (above), so this never takes SAFETY-03's `i_clamped` away from the rail.
if bound is not None:
held = max(float(bound[0]), min(float(bound[1]), i_w))
if held != i_w:
+3 -3
View File
@@ -3692,9 +3692,9 @@ class Controller:
# Filed only with battery modes on, and never on a battery in any
# maintenance phase: maintenance at 60/40 outranks the mode. The range
# always holds 0 W (packmode.mode_range()). pre_resolve() keeps it
# apart from the hard limits, and the allocator applies it only while
# the site target is decided at or below P_MODE, so the peak guard's
# site floor (P_PEAK) releases it and never meets it in a `lo > hi`.
# apart from the hard limits, and it gives way to the peak guard's
# site floor (P_PEAK) only as far as the floor needs, so the two never
# meet in a `lo > hi` (arbiter._unit_modes()).
if self.modes_on:
for inv, result in zip(self.inverters, maint_results):
if result.phase != IDLE:
+96
View File
@@ -694,6 +694,102 @@ check("...and with no mode claim at all, stage 2's answer is untouched "
resolve([Claim.set("loop", P_LOOP, 1200.0)], units=ONE).target_w
== 1200.0)
print()
print("OPT-11 11. a mode gives way only as far as the peak limit needs")
# Review of PR #149. The first cut released the modes only when a limit above
# P_MODE bound S. A trade (30) that won above the peak floor then kept the
# modes, and the units placed less than the floor: the mode beat the peak
# guard (a billed peak). And a peak limit that merely capped a charge released
# the modes, so an Off battery was charged from the grid. The rule now: clamp
# into what the modes can place, then back into the limits above the mode.
_offb = {"inverter-b": (0.0, 0.0)}
def _placed(r):
return sum(r.shares.values())
_ra = resolve(_two(0.0, arb=3000.0, peak_lo=2000.0, rating=1500.0,
modes=_offb)[:-1] + [
Claim.set("arbitrage", P_ARBITRAGE, 3000.0),
Claim.limit("peak", P_PEAK, lo=2000.0)], units=TWO)
print(f" trade 3000 W over a 2000 W floor, A 1500 W, B off: {_ra.shares}")
check("⭐ a trade above the peak floor with B Off: the units still place the "
"floor (2000 W), A to its rating and B only the 500 W A cannot give",
_placed(_ra) == 2000 and _ra.shares == {"inverter-a": 1500,
"inverter-b": 500})
_r1t = resolve(_one + [Claim.set("arbitrage", P_ARBITRAGE, 3000.0),
Claim.limit("peak", P_PEAK, lo=2000.0)], units=ONE)
check("⭐ ...and at N=1 an Off battery under a trade gives the peak floor "
"(2000 W), not 0 W", _r1t.target_w == 2000.0
and _r1t.bound_by == "peak")
_rc = resolve(_two(0.0, arb=-3000.0, peak_lo=-1000.0, modes=_offb),
units=TWO)
check("⭐ a grid charge the peak limit caps at 1000 W does not release B's "
"Off: A takes it all and B stays at 0 W",
_rc.shares == {"inverter-a": -1000, "inverter-b": 0})
_r1c = resolve(_one + [Claim.set("arbitrage", P_ARBITRAGE, -3000.0),
Claim.limit("peak", P_PEAK, lo=-1000.0)], units=ONE)
check("...and at N=1 an Off battery is not charged from the grid under a "
"capped trade", _r1c.target_w == 0.0)
_rp = resolve(_two(500.0, peak_lo=1500.0, modes=_offb), units=TWO)
check("a peak floor A can carry alone leaves B Off at 0 W",
_rp.shares == {"inverter-a": 1500, "inverter-b": 0}
and _rp.target_w == 1500.0)
_rall = resolve(_two(0.0, peak_lo=3000.0,
modes={"inverter-a": (0.0, 0.0),
"inverter-b": (0.0, 0.0)}), units=TWO)
check("every battery Off and a 3000 W peak floor: the floor is placed, "
"split between them, and nothing contradicts",
_placed(_rall) == 3000 and not _rall.contradiction
and _rall.allocation.refused is None)
import random as _rnd # noqa: E402
_g = _rnd.Random(149)
_worse, _needless, _sign, _nn = [], [], [], 0
for _ in range(20000):
_units = ("inverter-a", "inverter-b", "inverter-c")[:_g.choice((2, 3))]
_cl = []
for _u in _units:
_rt = _g.choice((1000.0, 2500.0))
_cl.append(Claim.limit("supervised", P_SAFETY, -_rt, _rt,
actuator=_u))
if _g.random() < 0.2:
_cl.append(Claim.limit("pack", P_SAFETY,
*_g.choice(((0.0, inf), (-inf, 0.0))),
actuator=_u))
_cl.append(Claim.limit(MODE_SOURCE, P_MODE,
_g.choice((0.0, -_rt)), _g.choice((0.0, _rt)),
actuator=_u))
_src = _g.choice(("loop", "arbitrage"))
_cl.append(Claim.set(_src, P_LOOP if _src == "loop" else P_ARBITRAGE,
_g.uniform(-7000.0, 7000.0)))
_pk = _g.uniform(-4000.0, 6000.0)
_cl.append(Claim.limit("peak", P_PEAK, lo=_pk))
_r = resolve(_cl, units=_units)
_r0 = resolve([c for c in _cl if c.source != MODE_SOURCE], units=_units)
_nn += 1
if _r.allocation.refused is not None:
_sign.append(_cl)
continue
if _placed(_r) < _pk - 1 and _placed(_r0) >= _pk - 1:
_worse.append(_cl)
# An Off unit gives power only when the peak floor is short without it.
_off = [c.actuator for c in _cl if c.source == MODE_SOURCE
and c.lo == 0.0 and c.hi == 0.0]
# What the units whose mode lets them give power can give, within it.
_on_cap = sum(max(0.0, min(_r.unit_bounds[u].hi, _r.unit_bounds[u].mode_hi))
for u in _units if _r.unit_bounds[u].mode_hi > 0.0
and _r.unit_bounds[u].lo <= 0.0)
if any(_r.shares.get(u, 0) > 0 for u in _off) and _pk <= _on_cap - 1:
_needless.append(_cl)
check(f"over {_nn} random N=2/3 cycles (modes, packs, a trade or the loop, a "
f"peak floor): no split is refused, the placed power never falls under "
f"the floor where the same cycle without modes met it, and an Off "
f"battery gives power only when the others cannot carry the floor "
f"({len(_sign)}, {len(_worse)}, {len(_needless)})",
not _sign and not _worse and not _needless)
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
+24
View File
@@ -1268,6 +1268,30 @@ for _ in range(4000):
check("a bound wider than the rail changes no Decision (4000 random cycles)",
_wide)
# (g) Review of PR #149: a bound EQUAL to the rail - every battery on, the
# default once modes are on - must leave SAFETY-03 exactly as it was. Before
# the fix the mode clamp ran first and took `i_clamped` away from the rail.
_rail_same, _rail_hits = True, 0
for _tb in (TB, Tuning(gain=0.6, max_w=5000.0, slew_w=400.0, deadband_w=15.0,
step_w=10, target_grid_w=-10.0,
integrator_max_w=7000.0)):
_lim = _tb.max_w
for _ in range(4000):
args = (_rngc.uniform(-5000, 5000), _rngc.uniform(-12000, 12000),
_rngc.uniform(-5000, 5000), _tb, _rngc.randint(0, 5),
_rngc.choice((None, _rngc.uniform(-8000, 8000))))
_d0 = compute(*args)
_rail_hits += _d0.i_clamped
if compute(*args, bound=(-_lim, _lim)) != _d0:
_rail_same = False
check(f"a bound equal to the rail changes no Decision, SAFETY-03's i_clamped "
f"included ({_rail_hits} of 8000 random cycles wind into the rail), and "
f"with integrator_max_w above max_w too", _rail_same and _rail_hits > 100)
_one_side = compute(4000.0, 12000.0, 4000.0, TB, 0, 4990.0,
bound=(0.0, 5000.0))
check("...and a bound that closes only the other side still lets the rail "
"flag a loop winding into it", _one_side.i_clamped)
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
+27 -2
View File
@@ -98,6 +98,12 @@ A5DDDAD = {
"n2": "a60003b1930fa3cba21f3220670d9172b9ff438347d77ba9bc3383fca1ceb15a",
"n1_off": "fc3bca170c46920f08d86baee62ea883954a89ea6222d6bbf7d6652877226262",
"n2_off": "a60003b1930fa3cba21f3220670d9172b9ff438347d77ba9bc3383fca1ceb15a",
# Added in review (PR #149), printed on a5dddad the same way: both
# batteries due for maintenance, and the arbiter alone on 6000 seeded
# claim lists with the peak floor, trades, maintenance and refusals.
"n1_maint": "5a21d43ec7cbf95a224bbb9bca13a8e62a00161101b586ae9fa68ab565992977",
"n2_maint": "48a1ad96121592e207a4664fb2da9f5208a49b88e5802a358873a5d30cb8c18e",
"resolve": "43a874216711936e14b9185bcc8d26c58fe4f3cfc3c1c8eaf89bffd95d6e81ef",
}
_claims, _undo_c = spy_claims()
_bounds, _undo_b = spy_bounds()
@@ -112,7 +118,8 @@ for k in A5DDDAD:
check("⭐ at N=1 and N=2, with the option absent and with it false, every "
"command, reason and allocation record over 540 cycles each is "
"byte-identical to a5dddad (house steps, a solar surplus, a battery "
"at its cut-out level, and at N=2 a refusal with probes)",
"at its cut-out level, at N=2 a refusal with probes, both batteries "
"due for maintenance), and so is the arbiter on 6000 claim lists",
_now == A5DDDAD)
check("...and no cycle in those runs filed a `mode` claim or handed "
"`compute()` a bound",
@@ -194,6 +201,20 @@ finally:
_undo_b()
check("...because main.py hands compute() the loop bound, B's 0 W included: "
"[-2500, 2500]", _bounds and set(_bounds) == {(-2500.0, 2500.0)})
# Review (PR #149): a unit the allocator drops (stale link) must not count in
# the loop bound either, or the loop asks for watts nobody live can place.
_rows, _c = rig.run(2, extra=ON, dur=10.0, load=flat, soc=lambda u, t: 50.0,
cut=lambda u, t: False)
_both = _c.loop_bound([app_main.Claim.limit(
"supervised", app_main.P_SAFETY, -2500.0, 2500.0,
actuator=_c.actuator_of("supervised", i)) for i in _c.inverters])
_c.live_units = lambda: (A,)
_one_live = _c.loop_bound([app_main.Claim.limit(
"supervised", app_main.P_SAFETY, -2500.0, 2500.0,
actuator=_c.actuator_of("supervised", i)) for i in _c.inverters])
check("the loop bound counts only live units: both live [-5000, 5000], B's "
"link stale [-2500, 2500]",
_both == (-5000.0, 5000.0) and _one_live == (-2500.0, 2500.0))
for _n in (1, 2):
_st = store_with(**{A: (False, packmode.SOLAR_FIRST),
@@ -310,10 +331,14 @@ check("pack_use stores the switch, and both are written to the action log",
_bad = [asyncio.run(_c.handle_action("pack_use", unit="inverter-z",
value=True)),
asyncio.run(_c.handle_action("pack_use", unit=A, value="yes")),
# 0 == False in Python: a stored 0 would read back as ON.
asyncio.run(_c.handle_action("pack_use", unit=A, value=0)),
asyncio.run(_c.handle_action("pack_use", unit=A, value=1)),
asyncio.run(_c.handle_action("pack_mode", unit=A,
value=packmode.CHEAP_HOURS)),
asyncio.run(_c.handle_action("pack_mode", unit=A, value=None))]
check("an unknown battery, a switch that is not true or false, and a mode "
check("an unknown battery, a switch that is not true or false (0 and 1 "
"included), and a mode "
"this release does not offer (Cheap hours arrives in P3) are refused, "
"with a plain reason, and store nothing",
all(isinstance(x, dict) and set(x) == {"error"} for x in _bad)
+79 -2
View File
@@ -14,7 +14,8 @@ printed on a5dddad (they are written there, with that provenance).
Scenarios: N=1 and N=2, a house that steps, a surplus of solar, a battery
reaching its cut-out level and, at N=2, a battery that refuses (SAFETY-73) and
is probed.
is probed; the same with both batteries due for maintenance; and the arbiter
alone on 6000 seeded claim lists (peak floor, trades, maintenance, refusals).
"""
import asyncio
@@ -187,6 +188,11 @@ def digest(rows) -> str:
return hashlib.sha256(repr(rows).encode()).hexdigest()
# Both batteries due for their monthly cycle at the run's first cycle, so the
# maintenance slot, its pins and its shaping are in every row (PR #149 review:
# the scenarios above never reach maintenance).
_MAINT = {"maintenance_enabled": True, "maintenance_start_hour": 11}
SCENARIOS = {
"n1": dict(n=1),
"n2": dict(n=2),
@@ -194,11 +200,78 @@ SCENARIOS = {
# option without turning it on runs. The old tree ignores the key.
"n1_off": dict(n=1, extra={"battery_modes_enabled": False}),
"n2_off": dict(n=2, extra={"battery_modes_enabled": False}),
"n1_maint": dict(n=1, extra=_MAINT),
"n2_maint": dict(n=2, extra=_MAINT),
}
def resolve_rows(cases=6000, seed=1149):
"""The arbiter alone, on seeded random claim lists with no mode claim:
the peak floor, a trade, the loop, maintenance pins and shaping, SAFETY-73
refusal limits and probe pins, packs, ratings and safety stops, at one to
three inverters. The peak guard needs a P1 meter the cycle runs above do
not have, so its claim is graded here. Uses only a5dddad's API."""
import random
from math import inf
from app import arbiter as a
rnd = random.Random(seed)
rows = []
for _ in range(cases):
n = rnd.choice((1, 2, 3))
units = ("inverter-a", "inverter-b", "inverter-c")[:n]
def act(src, u):
return a.actuator_for(src, u, units)
cl = []
for u in units:
r = rnd.choice((1000.0, 2500.0, 5000.0))
cl.append(a.Claim.limit("supervised", a.P_SAFETY, -r, r, "max_w",
actuator=act("supervised", u)))
x = rnd.random()
if x < 0.15:
cl.append(a.Claim.limit("pack", a.P_SAFETY, *rnd.choice(
((0.0, inf), (-inf, 0.0))), actuator=act("pack", u)))
elif x < 0.25:
cl.append(a.Claim.limit("refused", a.P_SAFETY, *rnd.choice(
((-inf, 0.0), (0.0, inf))), "refused",
actuator=act("refused", u)))
elif x < 0.32:
cl.append(a.Claim.set("refused", a.P_SAFETY,
rnd.choice((200.0, -200.0)), "probing",
actuator=act("refused", u)))
elif x < 0.42:
cl.append(a.Claim.set("maintenance", a.P_MAINTENANCE,
rnd.choice((2000.0, -2000.0)), "drain",
actuator=act("maintenance", u)))
elif x < 0.5:
cl.append(a.Claim.limit("maintenance", a.P_MAINT_SHAPE,
hi=-rnd.choice((500.0, 2000.0)),
actuator=act("maintenance", u)))
y = rnd.random()
if y < 0.8:
cl.append(a.Claim.set("loop", a.P_LOOP, rnd.uniform(-8000, 8000)))
if 0.5 < y < 0.9:
cl.append(a.Claim.set("arbitrage", a.P_ARBITRAGE,
rnd.uniform(-6000, 6000)))
if rnd.random() < 0.6:
cl.append(a.Claim.limit("peak", a.P_PEAK,
lo=rnd.uniform(-4000, 6000)))
if rnd.random() < 0.05:
cl.append(a.Claim.set("safety", a.P_SAFETY, 0.0, "stopped"))
rnd.shuffle(cl)
r = a.resolve(cl, units=units if n > 1 else None,
weights=(None if rnd.random() < 0.5 else
{u: rnd.choice((0.0, 0.5, 1.0)) for u in units}))
rows.append((r.target_w, r.winner, r.bound_by, r.contradiction,
tuple(sorted((r.shares or {}).items())), r.allocated,
r.allocation.explain() if r.allocation else None))
return rows
def digests() -> dict:
return {k: digest(run(**v)[0]) for k, v in SCENARIOS.items()}
out = {k: digest(run(**v)[0]) for k, v in SCENARIOS.items()}
out["resolve"] = digest(resolve_rows())
return out
if __name__ == "__main__":
@@ -208,5 +281,9 @@ if __name__ == "__main__":
print(f"{k}: {len(rows)} cycles, loop reasons "
f"{sorted({r[3] for r in rows})}, arbiter "
f"{sorted({r[6].split(' ->')[0] for r in rows})}")
rr = resolve_rows()
print(f"resolve: {len(rr)} claim lists, winners "
f"{sorted({r[1] for r in rr})}, bound by "
f"{sorted({str(r[2]).split('(')[0] for r in rr})}")
for k, v in digests().items():
print(f"{k} {v}")