Release 0.15.0: bump version and close the CHANGELOG section
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from SAFETY-94/97, no option change). New `## 0.15.0` section with the contents since 0.14.0 (cf705a9#171,3129dae#172) and the known issues. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -1,5 +1,39 @@
|
||||
# Changelog
|
||||
|
||||
## 0.15.0
|
||||
|
||||
**A minor bump: changed behaviour, and no option changes.** No option was
|
||||
added, removed or renamed, and no default changed (83 options). Options that
|
||||
start 0.14.0 also start 0.15.0. The changes below apply with one inverter and
|
||||
with two.
|
||||
|
||||
The add-on now learns and saves, per battery, what its power reading shows
|
||||
at rest (`unit/<name>/idle_w`). There is nothing to set.
|
||||
|
||||
Contents of this release, in merge order since 0.14.0 (`02ed120`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `cf705a9` | No more false "battery power reading stopped changing" stops at a new command after a rest, or at a change of phase. Each one held a battery at 0 W for about 17 s (about 4 a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. Each battery learns its own reading at rest (some show about −100 W), so a battery that refuses is still caught, now also with two inverters. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) |
|
||||
| `3129dae` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-14]]) |
|
||||
|
||||
### Known issues
|
||||
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
|
||||
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
|
||||
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
|
||||
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
|
||||
|
||||
### If you are crossing from a version older than 0.10.0
|
||||
|
||||
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
|
||||
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
|
||||
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
|
||||
bare options (`jq '.data.options'`) first.
|
||||
|
||||
## 0.14.0
|
||||
|
||||
**A minor bump: new behaviour with two inverters, and no option changes.**
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.14.0"
|
||||
version: "0.15.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
|
||||