Release 0.15.0: bump version and close the CHANGELOG section
checks / unit (pull_request) Successful in 29m1s
infra-pin / fresh (pull_request) Successful in 1s

config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from
SAFETY-94/97, no option change). New `## 0.15.0` section with the contents
since 0.14.0 (cf705a9 #171, 3129dae #172) and the known issues.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-05 00:48:04 +02:00
co-authored by Claude Opus 5.5
parent 3129daed62
commit f01152b113
2 changed files with 35 additions and 1 deletions
+34
View File
@@ -1,5 +1,39 @@
# Changelog
## 0.15.0
**A minor bump: changed behaviour, and no option changes.** No option was
added, removed or renamed, and no default changed (83 options). Options that
start 0.14.0 also start 0.15.0. The changes below apply with one inverter and
with two.
The add-on now learns and saves, per battery, what its power reading shows
at rest (`unit/<name>/idle_w`). There is nothing to set.
Contents of this release, in merge order since 0.14.0 (`02ed120`):
| | |
|---|---|
| `cf705a9` | No more false "battery power reading stopped changing" stops at a new command after a rest, or at a change of phase. Each one held a battery at 0 W for about 17 s (about 4 a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. Each battery learns its own reading at rest (some show about −100 W), so a battery that refuses is still caught, now also with two inverters. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) |
| `3129dae` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-14]]) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.14.0
**A minor bump: new behaviour with two inverters, and no option changes.**
+1 -1