DOC-8 review: say the field guide PDF is rebuilt, still v0.1.0
README and FIELD-GUIDE.md said the PDF was not rebuilt; it was, on 2026-10-17. Its content is still v0.1.0 and outdated. Rewrap the DOCS.md intro line. Text only. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
b8b357b552
commit
a4a7ff695e
+3
-3
@@ -4,9 +4,9 @@ The guide technicians carry is the PDF:
|
||||
|
||||
**`docs/GoodWe-RS485-Field-Guide.pdf`** — 10 pages, A4, print it double-sided.
|
||||
|
||||
⚠️ **Outdated: it is v0.1.0.** Its `slew_w` row is corrected in `build_guide.py`
|
||||
and `field-guide.html`, but the PDF has not been rebuilt (see below). Where the
|
||||
guide disagrees with `goodwe_controller/DOCS.md`, DOCS.md wins.
|
||||
⚠️ **Outdated: the content is still v0.1.0.** The PDF was rebuilt on 2026-10-17
|
||||
for the EMS-port wording and the `slew_w` row only. Where the guide disagrees with
|
||||
`goodwe_controller/DOCS.md`, DOCS.md wins.
|
||||
|
||||
It covers, in the order the work is done: pre-visit checks, hardware, firmware,
|
||||
add-on install and configuration, how to read the Web UI, the six commissioning
|
||||
|
||||
@@ -30,7 +30,7 @@ goodwe_controller/ the add-on
|
||||
returns, run against its own release image
|
||||
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
|
||||
estop/rs485_log.py optional RS485 e-stop / bus witness
|
||||
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4; outdated)
|
||||
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4; rebuilt 2026-10-17, content still v0.1.0 and outdated)
|
||||
docs/build_guide.py its single source - rebuilds the HTML and PDF
|
||||
FIELD-GUIDE.md how to edit and rebuild the guide
|
||||
docs/RELEASE.md how a change reaches the battery - `master` is
|
||||
|
||||
@@ -1,8 +1,9 @@
|
||||
# GoodWe RS485 Controller
|
||||
|
||||
Drives a GoodWe ES/BP battery inverter over its RS485 EMS port: sends it a grid
|
||||
reading to hold net grid exchange at zero, and runs a monthly battery maintenance cycle so the BMS can
|
||||
balance cells and recalibrate its coulomb counter.
|
||||
reading to hold net grid exchange at zero, and runs a monthly battery
|
||||
maintenance cycle so the BMS can balance cells and recalibrate its coulomb
|
||||
counter.
|
||||
|
||||
Installers: the printed field guide (`docs/GoodWe-RS485-Field-Guide.pdf`) is
|
||||
v0.1.0 and outdated; where it disagrees with this page, this page wins.
|
||||
|
||||