MAINT-28: during a real peak the maintenance charge stays paused #247

Merged
admin merged 11 commits from MAINT-28 into release/1.0 2026-11-13 06:23:13 +01:00
Owner

MAINT-24 follow-up (rig finding F-1). With A in maintenance CHARGE and the house over the month aim, the pause ended each time the guard idled, so A flipped charge/give (468 flips in 45 min on the rig, 11 at base 02eac3b). Now peakguard.shaping_held() keeps the pause until the house is 300 W under the aim. No cut-back is delayed or weakened; MAINT-24's night rate (1475 W live shape), N=1, the drain and modes off are unchanged.

Sim, real cycle(), house 6500 W for 45 min, banked month peak 6000 W (aim 5950 W):

02eac3b 1b5f7c9 MAINT-28
A charge/give flips in the load 0 52 1
grid min / max in the load (W) 3950 / 9024 3952 / 7994 3950 / 7994
quarter averages (W) 5959 5950 5950 5438 5502 5356 5923 5924 5041 4479 5356 4012 4000 4226 4476
A charging seconds in the load 0 367 301 (before the first trip)

DECISIONS: goodwe_controller/DECISIONS/MAINT-28-hold-the-pause-in-a-peak.md. Tests: test_maint28.py.

CHANGELOG: During a real peak above this month's peak, the monthly battery charge now stays paused instead of restarting every few seconds, until the house load is clear of the limit.

🤖 Generated with Claude Code

https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC

MAINT-24 follow-up (rig finding F-1). With A in maintenance CHARGE and the house over the month aim, the pause ended each time the guard idled, so A flipped charge/give (468 flips in 45 min on the rig, 11 at base 02eac3b). Now `peakguard.shaping_held()` keeps the pause until the house is 300 W under the aim. No cut-back is delayed or weakened; MAINT-24's night rate (1475 W live shape), N=1, the drain and modes off are unchanged. Sim, real `cycle()`, house 6500 W for 45 min, banked month peak 6000 W (aim 5950 W): | | 02eac3b | 1b5f7c9 | MAINT-28 | |---|---|---|---| | A charge/give flips in the load | 0 | 52 | 1 | | grid min / max in the load (W) | 3950 / 9024 | 3952 / 7994 | 3950 / 7994 | | quarter averages (W) | 5959 5950 5950 5438 5502 | 5356 5923 5924 5041 4479 | 5356 4012 4000 4226 4476 | | A charging seconds in the load | 0 | 367 | 301 (before the first trip) | DECISIONS: `goodwe_controller/DECISIONS/MAINT-28-hold-the-pause-in-a-peak.md`. Tests: `test_maint28.py`. CHANGELOG: During a real peak above this month's peak, the monthly battery charge now stays paused instead of restarting every few seconds, until the house load is clear of the limit. 🤖 Generated with [Claude Code](https://claude.com/claude-code) https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
admin added 1 commit 2026-11-12 21:52:05 +01:00
MAINT-28: during a real peak the maintenance charge stays paused until the house is clear of the aim
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Failing after 1h10m11s
8cd10ee6aa
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-12 22:28:05 +01:00
MAINT-28: the hold is for N=2 and up (SAFETY-87 N=1 pins), N=1 peak digest test
checks / unit (pull_request) Failing after 36m51s
infra-pin / fresh (pull_request) Successful in 2s
4f9aa5223f
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-12 22:44:34 +01:00
MAINT-28: reset the hold every cycle, test it; digests vs 1b5f7c9; DECISIONS numbers and mutants
checks / unit (pull_request) Failing after 36m49s
infra-pin / fresh (pull_request) Successful in 2s
92f0387415
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-12 23:14:01 +01:00
MAINT-28: hold only where MAINT-24 moved the aim (banked peak above the cap); test_safety119 pins stay
checks / unit (pull_request) Failing after 34m27s
infra-pin / fresh (pull_request) Successful in 2s
8640bfcbc1
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-12 23:29:15 +01:00
MAINT-28: test_maint28 points at MUTATION.md (test_bytecode)
checks / unit (pull_request) Failing after 34m49s
infra-pin / fresh (pull_request) Successful in 1s
23359a047d
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-12 23:58:21 +01:00
MAINT-28: keep the single shaping_suspended(.., maint_aim) call site (test_peak_margin pin); shaping_held takes its answer
checks / unit (pull_request) Successful in 32m46s
infra-pin / fresh (pull_request) Successful in 1s
edf30f345a
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-13 00:20:26 +01:00
MAINT-28: N=1 digest test with a banked peak (so the N=1 gate is tested)
checks / unit (pull_request) Successful in 34m0s
infra-pin / fresh (pull_request) Successful in 2s
bc5be4964e
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-13 00:59:44 +01:00
MAINT-28: re-pin test_safety84 n2_charge_banked (the charge no longer restarts in the 5000 W load)
checks / unit (pull_request) Successful in 43m17s
infra-pin / fresh (pull_request) Successful in 2s
f5bd2a3520
Co-Authored-By: Claude <noreply@anthropic.com>
admin added 1 commit 2026-11-13 02:29:33 +01:00
admin added 1 commit 2026-11-13 03:57:34 +01:00
MAINT-28: test_maint28 reads the replay clock directly (main_files.live parsed every app file per cycle): 269 s -> 28 s, same numbers
checks / unit (pull_request) Successful in 42m47s
infra-pin / fresh (pull_request) Successful in 2s
7edf8484d1
Co-Authored-By: Claude <noreply@anthropic.com>
Author
Owner

MAINT-28 review of 7edf848 (independent, Opus). Verdict: NOT READY. One docs change only; the code is fine.

The code, the tests, CI and the local suite all pass. The only thing blocking is a wrong reason in DECISIONS for the energy trade-off.

Findings

M-1 (Medium, docs) goodwe_controller/DECISIONS/MAINT-28-hold-the-pause-in-a-peak.md:17. The note says: "A cap on that give would conflict with the guard's lo (lo > hi resolves to 0 W), so it is not tried here." That is not true for the state the hold adds:

  • While the guard is idle, peakguard.claim() files no claim at all (app/peakguard.py:482).
  • While the guard is engaged, suspended is true and the shaping claim is dropped as before.

So a hi = 0 claim filed only while the pause is held and the guard is idle never meets a lo. I measured that option in a scratch tree (not proposed for merge; same 45-min sim, scratch/MAINT-28/review/repro_alt.txt):

  • A gives 0.44 kWh instead of 1.66 kWh.
  • Quarters 5919 and 5915 W, under the aim.
  • 1 charge/give flip.
  • But A switches between giving and idle 32 times in 40 min, and the guard toggles (engaged in 662 of 2400 cycles).

The choice in this PR is still the better one: one steady give, which is the point of the card. But the stated reason is wrong. Fix: replace that sentence with the real reason and these numbers. A cap is possible. It saves about 1.2 kWh per 45-min peak but brings back a give/idle toggle at the guard's edge (32 in 40 min in the sim). No code change.

L-1 (Low, style) goodwe_controller/app/ctl_cycle.py:571-574. The comment is 4 lines and has no DECISIONS pointer; the reset comment at 540-542 has one. Make it one line plus the pointer.

L-2 (Low, report only). The "grid min in the load" values in the dev report and PR table (452 / 2988 / 3485 W) are the last sample of the load: the house steps down while A is still giving. On all three heads the real minimum in the load is about 3950 W (see the review report). The DECISIONS table does not carry these values, so no change is needed there.

Info. After a real peak, while the house sits 0-300 W under the aim, the charge stays off and A gives for the house. At 1b5f7c9, A would charge 150 W or less in that band. This is rare and only ever moves toward less grid draw.

Checks

  1. Numbers match the dev's table exactly: flips, quarters, A charge seconds, out/in kWh, charge back after 3 s, on 02eac3b, 1b5f7c9 and 7edf848.

    • Live-shape night: 0 / -1476 / -1476 W. The pause never comes on 1b5f7c9 or 7edf848 (02eac3b: 596 paused cycles).
    • The B-in-CHARGE mirror (15-min load): 18 flips on 1b5f7c9, 1 on 7edf848.
  2. Safety: no issue.

    • The hold only stops a shaping claim from being filed. It never adds a claim or delays the guard's claim.
    • The N=1, n1_peak, drain and modes-off digests are the same as 1b5f7c9.
    • Forecast unreadable: the hold only follows a real guard step-in, and with neither forecast nor house reading it lets go (SAFETY-63).
    • Late readings: the two early returns write nothing; a reading late by stale_after or more files the safety SET of 0 W, which wins.
    • Shadow mode: same path, nothing written.
    • Month start: the maint_aim > peak_aim_w() gate ends the hold on the first cycle of a new month.
  3. Give cost. While the pause is held and the guard is idle, no shaping claim is filed, so the loop runs A as a normal battery: A gives a mean of 2496 W, its full rating, and the grid sits near 4000 W. The quarter only needs about 550 W. The cost is about 1.2 kWh more through A per 45-min real peak:

    • Money: a few cents of round-trip loss. The energy replaces grid power bought at the same night price.
    • Delay: about 50 min more maintenance charge at 1475 W. That is far inside CHARGE_TIMEOUT_MIN (2160 open minutes).

    Acceptable as is: it buys the steadiness the card asked for. It only needs the correct reason in DECISIONS (M-1).

  4. _maint_peak_hold lifetime: keep as is.

    • Any cycle that reaches the maintenance loop without the charge-only branch clears the flag (part 1b, M4).
    • On a same-cycle pack switch the flag carries over, but each cycle checks it again against the measured house (more than aim - 300) and the month gate, so it can only keep a charge of 150 W or less off.
    • Restart: the flag starts at False and is not stored.
    • Moving the reset to the top of cycle() would be worse: each missed poll would restart the charge, one flap per missed poll.
  5. Tests.

    • test_maint28 passes on 7edf848 and fails on 1b5f7c9 (6 checks).
    • M1-M6 each fail (4/2/4/2/1/1 failing checks).
    • The five AT_BASE digests are the same on a clean 1b5f7c9 with a stub, so they are true base values.
    • test_safety84 n2_charge_banked: 64 of 480 rows differ. Rows 310-371 (t = 1550-1855 s): A no longer charges -127 W; A and B give 2500 W each while the load runs. Rows 387-388: a small difference at the restart. The other five pins are the same. It moves by design.
    • The replay clock: ctl_cycle reads datetime as a global (line 49), so main_files.live patches it with the same _DT. It is a faithful stand-in.
  6. Docs. The DECISIONS note is short, has no duplicate paragraph, and its sha and numbers are right; the one wrong sentence is M-1. The CHANGELOG line is in the PR body and CHANGELOG.md is not touched. No new user text.

  7. CI and suite.

    • CI runs 1634 (checks / unit) and 1635 (infra-pin / fresh): success on head_sha 7edf848.
    • Local full suite (goodwe-addon-checks:1, --network none, :ro mount, real hwsim): 107 files, 0 failed, 1593 s wall. test_maint28 78 s.

Not merged (M-1 is above Low). Details: reports/MAINT-28-review-report.md.

**MAINT-28 review of 7edf848 (independent, Opus). Verdict: NOT READY. One docs change only; the code is fine.** The code, the tests, CI and the local suite all pass. The only thing blocking is a wrong reason in DECISIONS for the energy trade-off. ### Findings **M-1 (Medium, docs) `goodwe_controller/DECISIONS/MAINT-28-hold-the-pause-in-a-peak.md:17`.** The note says: "A cap on that give would conflict with the guard's `lo` (`lo > hi` resolves to 0 W), so it is not tried here." That is not true for the state the hold adds: - While the guard is idle, `peakguard.claim()` files no claim at all (`app/peakguard.py:482`). - While the guard is engaged, `suspended` is true and the shaping claim is dropped as before. So a `hi = 0` claim filed only while the pause is held and the guard is idle never meets a `lo`. I measured that option in a scratch tree (not proposed for merge; same 45-min sim, `scratch/MAINT-28/review/repro_alt.txt`): - A gives 0.44 kWh instead of 1.66 kWh. - Quarters 5919 and 5915 W, under the aim. - 1 charge/give flip. - But A switches between giving and idle 32 times in 40 min, and the guard toggles (engaged in 662 of 2400 cycles). The choice in this PR is still the better one: one steady give, which is the point of the card. But the stated reason is wrong. Fix: replace that sentence with the real reason and these numbers. A cap is possible. It saves about 1.2 kWh per 45-min peak but brings back a give/idle toggle at the guard's edge (32 in 40 min in the sim). No code change. **L-1 (Low, style) `goodwe_controller/app/ctl_cycle.py:571-574`.** The comment is 4 lines and has no DECISIONS pointer; the reset comment at 540-542 has one. Make it one line plus the pointer. **L-2 (Low, report only).** The "grid min in the load" values in the dev report and PR table (452 / 2988 / 3485 W) are the last sample of the load: the house steps down while A is still giving. On all three heads the real minimum in the load is about 3950 W (see the review report). The DECISIONS table does not carry these values, so no change is needed there. **Info.** After a real peak, while the house sits 0-300 W under the aim, the charge stays off and A gives for the house. At 1b5f7c9, A would charge 150 W or less in that band. This is rare and only ever moves toward less grid draw. ### Checks 1. **Numbers match the dev's table exactly**: flips, quarters, A charge seconds, out/in kWh, charge back after 3 s, on 02eac3b, 1b5f7c9 and 7edf848. - Live-shape night: 0 / -1476 / -1476 W. The pause never comes on 1b5f7c9 or 7edf848 (02eac3b: 596 paused cycles). - The B-in-CHARGE mirror (15-min load): 18 flips on 1b5f7c9, 1 on 7edf848. 2. **Safety: no issue.** - The hold only stops a shaping claim from being filed. It never adds a claim or delays the guard's claim. - The N=1, `n1_peak`, drain and modes-off digests are the same as 1b5f7c9. - Forecast unreadable: the hold only follows a real guard step-in, and with neither forecast nor house reading it lets go (SAFETY-63). - Late readings: the two early returns write nothing; a reading late by `stale_after` or more files the safety SET of 0 W, which wins. - Shadow mode: same path, nothing written. - Month start: the `maint_aim > peak_aim_w()` gate ends the hold on the first cycle of a new month. 3. **Give cost.** While the pause is held and the guard is idle, no shaping claim is filed, so the loop runs A as a normal battery: A gives a mean of 2496 W, its full rating, and the grid sits near 4000 W. The quarter only needs about 550 W. The cost is about 1.2 kWh more through A per 45-min real peak: - Money: a few cents of round-trip loss. The energy replaces grid power bought at the same night price. - Delay: about 50 min more maintenance charge at 1475 W. That is far inside `CHARGE_TIMEOUT_MIN` (2160 open minutes). **Acceptable as is**: it buys the steadiness the card asked for. It only needs the correct reason in DECISIONS (M-1). 4. **`_maint_peak_hold` lifetime: keep as is.** - Any cycle that reaches the maintenance loop without the charge-only branch clears the flag (part 1b, M4). - On a same-cycle pack switch the flag carries over, but each cycle checks it again against the measured house (more than aim - 300) and the month gate, so it can only keep a charge of 150 W or less off. - Restart: the flag starts at False and is not stored. - Moving the reset to the top of `cycle()` would be worse: each missed poll would restart the charge, one flap per missed poll. 5. **Tests.** - `test_maint28` passes on 7edf848 and fails on 1b5f7c9 (6 checks). - M1-M6 each fail (4/2/4/2/1/1 failing checks). - The five AT_BASE digests are the same on a clean 1b5f7c9 with a stub, so they are true base values. - `test_safety84` `n2_charge_banked`: 64 of 480 rows differ. Rows 310-371 (t = 1550-1855 s): A no longer charges -127 W; A and B give 2500 W each while the load runs. Rows 387-388: a small difference at the restart. The other five pins are the same. It moves by design. - The replay clock: `ctl_cycle` reads `datetime` as a global (line 49), so `main_files.live` patches it with the same `_DT`. It is a faithful stand-in. 6. **Docs.** The DECISIONS note is short, has no duplicate paragraph, and its sha and numbers are right; the one wrong sentence is M-1. The CHANGELOG line is in the PR body and CHANGELOG.md is not touched. No new user text. 7. **CI and suite.** - CI runs 1634 (`checks / unit`) and 1635 (`infra-pin / fresh`): success on head_sha 7edf848. - Local full suite (`goodwe-addon-checks:1`, `--network none`, `:ro` mount, real hwsim): 107 files, 0 failed, 1593 s wall. `test_maint28` 78 s. Not merged (M-1 is above Low). Details: `reports/MAINT-28-review-report.md`.
admin added 1 commit 2026-11-13 05:53:58 +01:00
MAINT-28: DECISIONS gives the measured reason for the uncapped give (review M-1); ctl_cycle comment one line + pointer (L-1)
checks / unit (pull_request) Successful in 27m38s
infra-pin / fresh (pull_request) Successful in 2s
e7706150e8
Co-Authored-By: Claude <noreply@anthropic.com>
admin merged commit f3f9483d9c into release/1.0 2026-11-13 06:23:13 +01:00
Author
Owner

Re-review of e770615: MERGE-READY as is, and now merged. release/1.0 is f3f9483 (normal merge; parents 1b5f7c9 and e770615).

  • git diff 7edf848 e770615 changes only DECISIONS and one code comment. No behaviour change.
  • M-1 fixed. DECISIONS now gives the measured reason for not capping A's give: A gives 0.44 vs 1.66 kWh, quarters 5919/5915 W, 32 give/idle switches in 40 min. These numbers match my repro_alt.txt.
  • L-1 fixed. ctl_cycle.py comment is now one line plus the DECISIONS pointer.
  • L-2 fixed. The grid minimum is now 3950 / 3952 / 3950 W in the PR body table and in the dev report.
  • CI: runs 1636 (checks / unit) and 1637 (infra-pin / fresh) both succeeded on e770615 (checked through the API).
  • No findings left above Low.
**Re-review of e770615: MERGE-READY as is, and now merged.** release/1.0 is f3f9483 (normal merge; parents 1b5f7c9 and e770615). - `git diff 7edf848 e770615` changes only DECISIONS and one code comment. No behaviour change. - **M-1 fixed.** DECISIONS now gives the measured reason for not capping A's give: A gives 0.44 vs 1.66 kWh, quarters 5919/5915 W, 32 give/idle switches in 40 min. These numbers match my `repro_alt.txt`. - **L-1 fixed.** `ctl_cycle.py` comment is now one line plus the DECISIONS pointer. - **L-2 fixed.** The grid minimum is now 3950 / 3952 / 3950 W in the PR body table and in the dev report. - **CI:** runs 1636 (`checks / unit`) and 1637 (`infra-pin / fresh`) both succeeded on e770615 (checked through the API). - No findings left above Low.
Sign in to join this conversation.