# MAINT-14 - no SoC reading in a maintenance cycle
**Status: for review.** Tests: `test_maint14.py`. No option added; the one new
number is a constant in `app/maintenance.py`.
**The fault.** `Maintenance.tick()` returned early when the SoC was `None`,
before any timeout check. (1) A charge on a pack whose SoC reading was lost
never ended: no timeout, no back-off, no notice, and the 7-day backstop of
MAINT-13 sat behind the same return. (2) A drain kept commanding `discharge_w`
with an unknown level, which breaks the TEL-08 rule that an unknown level never
allows discharge.
## Rules
1. **Charge, no SoC.** The charge timeout (`CHARGE_TIMEOUT_MIN`, gate-open
minutes) and the 7-day wall backstop still run. When one fires: if the last
SoC seen was >= target - 3 the charge counts as done (the MAINT-13 "close
enough to full" rule, HOLD follows); otherwise it fails: MAINT-13 back-off
and its one notification. If no SoC was ever seen, it fails.
2. **Drain, no SoC.** DRAIN holds at 0 W and owns the setpoint, exactly as HOLD
does. The 12 h drain timeout still runs and fails as before.
3. **SoC comes back.** Nothing is recorded; the drain continues at the drain
rate, the charge carries on, and the stall wait of MAINT-13 restarts from
what it was: it paused while the reading was missing, so a gap never counts
as "no more charge".
4. **HOLD** is unchanged (0 W).
5. **Log.** One line when a drain starts holding for this reason ("the battery
level is unknown, so the drain holds at 0 W until it is back"), and one line
when the level has been missing for `NOSOC_NOTE_MIN` = 15 min. Both are said
once per episode; the old line that repeated every tick is gone.
## Why
- **"Last seen", not "best seen".** A pack that was at 99 and then dropped to 50
before the reading went is not close to full. Only the last reading counts.
It is saved with the charge record (`charge_track.last`), and saved at once
when the reading first goes missing, so a restart mid-gap still knows it
(within the usual 5 min save interval otherwise).
- **Failure when nothing was seen.** With no level we cannot call a pack full.
The failure costs a 7-day wait and one notice; calling it done costs a
missed balance and a month-long false "complete". The first is the honest one.
- **Timeouts count the same minutes as with a reading.** Gate-open charging
minutes only; the wall backstop for a gate that never opens.
- **15 min.** A judgement. A poll glitch of a few minutes should not write a
line; a reading lost for a quarter of an hour is worth one. Raise it if the
action log shows noise.
- **0 W, not "stop the phase".** Aborting a drain on a short gap would throw
away the part already drained. Holding at 0 W loses nothing and the 12 h
timeout is the limit.
## Cost
- A drain that loses its reading stops draining, and the 12 h clock keeps
running. A gap of many hours can therefore fail a drain that was working. The
back-off then applies (7 days).
- A charge whose reading is lost early (last SoC below target - 3) fails at the
timeout, even if the pack was in fact filling. The same 7-day wait applies.
## What this does not cover
- **HOLD with no SoC** still holds 0 W and, as before, does not end while the
reading is missing: its time check sits behind the same early return. A HOLD
needs no level to end, so this is a candidate follow-up, not part of this fix.
- It does not tell the operator why the reading is missing (sensor, register,
link). It does not reuse the stale-input gate; it is the cycle's own rule.
- The charge itself is still driven by the control loop, which has its own
handling of a missing SoC (TEL-08 for the loop is a separate card).
- A restart loses at most 5 min of accounting, as in MAINT-13. The "unknown for
long" line may be said again after a restart: the episode start is in memory.
- Text added is two log lines, English only, like the other log lines.
+79 -9
View File
@@ -84,6 +84,10 @@ FAIL_BACKOFF_DAYS = 7
CHARGE_TICK_MAX_MIN = 5
# The charge accounting is written to the state file at most this often.
CHARGE_SAVE_MIN = 5
# MAINT-14 (DECISIONS/MAINT-14-no-soc-in-maintenance.md): with no SoC reading
# the timeouts still run, a drain holds at 0 W, and the log says once, after this
# many minutes, that the level has been unknown for long.
NOSOC_NOTE_MIN = 15
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
# OPTION, and the only place in the add-on where one of these numbers is typed.
@@ -367,6 +371,10 @@ class Maintenance:
# written to the state file every CHARGE_SAVE_MIN minutes.
self._trk = None
self._trk_saved = None
# MAINT-14: when the SoC reading went missing (None while it is there),
# and whether the "unknown for long" line was said in this episode.
self._nosoc_since = None
self._nosoc_said = False
# -- state ---------------------------------------------------------------
@property
@@ -374,6 +382,7 @@ class Maintenance:
return self.store.get("phase", IDLE)
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
self._nosoc_since = None
self._trk = None
self._trk_saved = None
if self.store.get("charge_track") is not None:
@@ -473,7 +482,8 @@ class Maintenance:
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
return events
def _charge_account(self, now: datetime, soc: float, gate_open: bool) -> dict:
def _charge_account(self, now: datetime, soc: float | None,
gate_open: bool) -> dict:
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
`open_min` counts only ticks with the price gate open; `flat_min` counts
@@ -481,6 +491,9 @@ class Maintenance:
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
counts for nothing. A state file from before MAINT-13, or from another
charge, starts from the wall-clock minutes so far: the old behaviour.
MAINT-14: `soc` may be None (no reading). Time still counts, the stall
wait pauses, and `last` keeps the last SoC seen (saved with the rest).
"""
since = self.store.get("phase_started")
trk = self._trk
@@ -490,7 +503,9 @@ class Maintenance:
trk = dict(raw)
else:
trk = {"since": since, "open_min": self._elapsed_min(now),
"flat_min": 0.0, "best": float(soc), "at": None}
"flat_min": 0.0,
"best": None if soc is None else float(soc),
"last": None if soc is None else float(soc), "at": None}
self._trk = trk
at = trk.get("at")
try:
@@ -500,10 +515,14 @@ class Maintenance:
dt = 0.0 if last is None else min(
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
trk["at"] = now.isoformat()
if soc > trk["best"]:
if soc is None:
pass
elif trk.get("best") is None or soc > trk["best"]:
trk["best"], trk["flat_min"] = float(soc), 0.0
elif gate_open:
trk["flat_min"] += dt
if soc is not None:
trk["last"] = float(soc)
if gate_open:
trk["open_min"] += dt
saved = self._trk_saved
@@ -522,6 +541,57 @@ class Maintenance:
events.append(msg)
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
events: list) -> MaintResult:
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
time is a failure, except when the last SoC seen was within
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
Nothing here may start a phase change that needs the level.
"""
if self._nosoc_since is None:
self._nosoc_since = now
self._nosoc_said = False
self._trk_saved = None # save the last SoC seen, now
if phase == DRAIN:
msg = ("maintenance: the battery level is unknown, so the "
"drain holds at 0 W until it is back.")
_LOG.warning("%s", msg)
events.append(msg)
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
>= NOSOC_NOTE_MIN * 60):
self._nosoc_said = True
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
f"The time limit of the {phase} still applies.")
_LOG.warning("%s", msg)
events.append(msg)
if phase == HOLD:
return MaintResult(HOLD, True, 0.0, False, events)
elapsed = self._elapsed_min(now)
if phase == DRAIN:
if elapsed > DRAIN_TIMEOUT_MIN:
return self._fail(now, "drain",
f"drain stuck, battery level unknown, after "
f"{elapsed / 60:.0f} h")
return MaintResult(DRAIN, True, 0.0, False, events)
trk = self._charge_account(now, None, gate_open)
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
last = trk.get("last")
if last is not None and last >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT:
self._enter(HOLD, now, events,
f"maintenance: charge time is up and the last level "
f"seen was {last:.0f} %, close enough to full, so the "
f"charge counts as done -> holding "
f"{self.cfg.hold_min} min to balance")
return MaintResult(HOLD, True, 0.0, False, events)
return self._fail(now, "charge",
f"charge stuck, battery level unknown, after "
f"{trk['open_min'] / 60:.0f} h of charging time")
return MaintResult(CHARGE, False, None, True, events)
def abort(self, now: datetime, why: str) -> list:
events = []
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
@@ -609,13 +679,13 @@ class Maintenance:
# transitions below mean anything, and a stale "100 %" would end the
# charge phase having charged nothing. Hold the current phase's command
# and wait; the phase timeout is the backstop.
#
# MAINT-14: "hold and wait" is not "wait for ever". The timeouts run
# here too, and a drain holds at 0 W (an unknown level never allows
# discharge, TEL-08). See `_no_soc`.
if soc is None:
_LOG.warning("maintenance: no SoC reading, holding phase %s", phase)
if phase == DRAIN:
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
if phase == HOLD:
return MaintResult(HOLD, True, 0.0, False, events)
return MaintResult(CHARGE, False, None, True, events)
return self._no_soc(now, phase, gate_open, events)
self._nosoc_since = None
elapsed = self._elapsed_min(now)
+356
View File
@@ -0,0 +1,356 @@
"""MAINT-14: maintenance with no SoC reading.
`python3 test_maint14.py`
Graded here: charge and drain with SoC None at one and two packs - the charge
timeout and 7 day backstop still run (failure, or done when the last SoC was
>= target - 3), the drain holds at 0 W and times out, SoC coming back resumes
normally with no back-off, the log lines (once per episode), a restart while the
SoC is missing, and one pack's missing SoC leaving the other pack alone.
See DECISIONS/MAINT-14-no-soc-in-maintenance.md.
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
"""
import os
import sys
import tempfile
from datetime import datetime, timedelta, timezone
from app.maintenance import (
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_TIMEOUT_MIN, CHARGE_WALL_TIMEOUT_MIN,
DRAIN, DRAIN_TIMEOUT_MIN, FAIL_BACKOFF_DAYS, HOLD, IDLE, NOSOC_NOTE_MIN,
MaintConfig, Maintenance, arbitrate,
)
from app.store import DEFAULTS, Store
UTC = timezone.utc
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
discharge_w=2000, charge_w=2000, soc_floor=11,
soc_target=100, hold_min=120)
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
MIN = timedelta(minutes=1)
class Mem:
def __init__(self, data=None):
self.data = dict(DEFAULTS, **(data or {}))
def set(self, k, v):
self.data[k] = v
def set_time(self, k, when):
self.data[k] = when.astimezone(UTC).isoformat() if when else None
def get_time(self, k):
raw = self.data.get(k)
return datetime.fromisoformat(raw) if raw else None
def save(self):
pass
def in_drain(store=None, unit=None, at=T0):
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
m.force_start(at)
assert m.phase == DRAIN
return m
def in_charge(store=None, unit=None, at=T0):
m = in_drain(store, unit, at)
m.tick(at, 11.0)
assert m.phase == CHARGE
return m
def run(m, start, minutes, soc, gate=True, step=1):
"""Tick every `step` min; returns (last result, end time, first result that
is not the starting phase with its time, all events)."""
ph, t, res, out, ev = m.phase, start, None, None, []
for i in range(0, minutes, step):
t = start + i * MIN
s = soc(i) if callable(soc) else soc
res = m.tick(t, s, gate_open=gate)
ev += res.events
if out is None and res.phase != ph:
out = (res, t)
break
return res, start + minutes * MIN, out, ev
print("1. charge with no SoC")
m = in_charge()
res, _, out, _ = run(m, T0, 600, None)
check("it keeps charging: the loop owns the setpoint, no start of a new phase",
out is None and res.phase == CHARGE and res.charge_only
and not res.owns_setpoint)
m = in_charge()
run(m, T0, 60, 60.0)
res, _, out, ev = run(m, T0 + 60 * MIN, CHARGE_TIMEOUT_MIN + 10, None)
check("the charge timeout still runs: it fails once the time is up (last SoC 60)",
out and out[0].failed == "charge" and out[0].phase == IDLE)
check("...with the MAINT-13 back-off and its one plain line",
m.store.get_time("last_failed") is not None
and sum("did not finish" in e for e in ev) == 1
and f"{FAIL_BACKOFF_DAYS} days" in ev[-1])
check("...it took 36 h of allowed time from the charge start, not more",
out and out[1] <= T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 10))
check("...and the pack does not want a start in the back-off",
not m.wants_start((T0 + timedelta(days=3)).replace(hour=19)))
m = in_charge()
res, _, out, _ = run(m, T0, CHARGE_TIMEOUT_MIN + 10, None)
check("never saw a SoC: the timeout is a failure, not 'done'",
out and out[0].failed == "charge")
for last in (97.0, 99.0):
m = in_charge()
run(m, T0, 10, last)
res, _, out, ev = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
check(f"last SoC {last:.0f} (>= target - {CHARGE_NEAR_FULL_PCT}): time up counts as done",
out and out[0].phase == HOLD and out[0].failed == ""
and m.store.get_time("last_failed") is None)
check("...one plain line says so",
sum("counts as done" in e for e in ev) == 1
and f"{last:.0f} %" in " ".join(ev))
m = in_charge()
run(m, T0, 10, 96.0)
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
check("last SoC 96 (below target - 3): time up is a failure",
out and out[0].failed == "charge")
m = in_charge()
run(m, T0, 10, 99.0)
run(m, T0 + 10 * MIN, 10, 50.0)
res, _, out, _ = run(m, T0 + 20 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
check("'last seen' is the last reading, not the best (99 then 50: failure)",
out and out[0].failed == "charge")
print("2. the 7 day backstop, with the gate shut")
m = in_charge()
run(m, T0, 10, 70.0)
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
gate=False, step=5)
check("gate never opens, last SoC 70: failure at 7 days",
out and out[0].failed == "charge"
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN)
and out[1] <= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN + 10))
m = in_charge()
run(m, T0, 10, 98.0)
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
gate=False, step=5)
check("gate never opens, last SoC 98: done at 7 days",
out and out[0].phase == HOLD and out[0].failed == ""
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN))
m = in_charge()
run(m, T0, 10, 70.0)
res, _, out, _ = run(m, T0 + 10 * MIN, 3000, None, gate=False, step=5)
check("gate shut, no SoC: the open-time clock does not run (no early end)",
out is None)
print("3. SoC comes back mid-charge")
m = in_charge()
run(m, T0, 30, 80.0)
run(m, T0 + 30 * MIN, 600, None)
res, _, out, _ = run(m, T0 + 630 * MIN, 5, 80.0)
check("normal behaviour resumes: still charging, nothing recorded",
out is None and res.phase == CHARGE
and m.store.get_time("last_failed") is None)
res, _, out, _ = run(m, T0 + 640 * MIN, 10, 100.0)
check("...and it completes at the target as usual",
out and out[0].phase == HOLD and m.store.get_time("last_failed") is None)
m = in_charge()
run(m, T0, 30, 98.0)
run(m, T0 + 30 * MIN, 600, None)
res, _, out, _ = run(m, T0 + 630 * MIN, 30, 98.0)
check("the stall wait paused while the SoC was missing (30 min flat after the "
"gap is not 60)", out is None)
res, _, out, _ = run(m, T0 + 660 * MIN, 40, 98.0)
check("...and completes once 60 min flat are in", out and out[0].phase == HOLD)
m = in_charge()
run(m, T0, 10, 70.0)
run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN - 100, None)
res, _, out, _ = run(m, T0 + (CHARGE_TIMEOUT_MIN - 90) * MIN, 5, 70.0)
check("a gap just before the limit then a reading: no failure, no back-off",
out is None and m.store.get_time("last_failed") is None)
print("4. drain with no SoC")
m = in_drain()
run(m, T0, 30, 60.0)
res, _, out, ev = run(m, T0 + 30 * MIN, 60, None)
check("DRAIN holds at 0 W, owned by maintenance, the same as HOLD",
out is None and res.phase == DRAIN and res.owns_setpoint
and res.setpoint_w == 0.0 and not res.charge_only)
hold = in_charge()
hold.tick(T0 + MIN, 100.0)
hr = hold.tick(T0 + 2 * MIN, None)
check("...the same answer as HOLD gives",
(hr.owns_setpoint, hr.setpoint_w) == (res.owns_setpoint, res.setpoint_w))
check("never above 0 W on any missing tick",
all(m.tick(T0 + (100 + i) * MIN, None).setpoint_w == 0.0 for i in range(30)))
check("one plain line that the drain holds, once, not per tick",
sum("drain holds at 0 W" in e for e in ev) == 1)
check("one plain line after the threshold, once",
sum("no battery level for" in e for e in ev) == 1
and f"{NOSOC_NOTE_MIN} min" in " ".join(ev))
m = in_drain()
res, _, out, ev = run(m, T0, NOSOC_NOTE_MIN - 1, None)
check("under the threshold the 'no level for long' line is not said",
not any("no battery level for" in e for e in ev))
m = in_drain()
res, _, out, ev = run(m, T0, DRAIN_TIMEOUT_MIN + 10, None)
check("the 12 h drain timeout still runs: failure with back-off",
out and out[0].failed == "drain" and out[0].phase == IDLE
and out[1] > T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN)
and m.store.get_time("last_failed") is not None)
m = in_drain()
run(m, T0, 60, None)
res, _, out, _ = run(m, T0 + 60 * MIN, 5, 60.0)
check("SoC back: the drain continues at the drain rate",
out is None and res.phase == DRAIN and res.owns_setpoint
and res.setpoint_w == CFG.discharge_w)
res, _, out, _ = run(m, T0 + 70 * MIN, 5, 10.0)
check("...and ends at the floor as usual",
out and out[0].phase == CHARGE and m.store.get_time("last_failed") is None)
m = in_drain()
run(m, T0, 60, None)
run(m, T0 + 60 * MIN, 5, 60.0)
res, _, out, ev = run(m, T0 + 70 * MIN, 5, None)
check("a second episode says its lines again",
any("drain holds at 0 W" in e for e in ev))
print("5. the log is once per episode")
m = in_charge()
res, _, out, ev = run(m, T0, 300, None)
check("a 5 h charge episode: exactly one 'no level for long' line, none per tick",
len(ev) == 1 and "no battery level for" in ev[0])
run(m, T0 + 300 * MIN, 3, 70.0)
res, _, out, ev = run(m, T0 + 303 * MIN, 60, None)
check("...and one more for a new episode", len(ev) == 1)
m = in_charge()
res, _, out, ev = run(m, T0, 5, None)
check("a 5 min gap says nothing", ev == [])
print("6. restart while the SoC is missing")
with tempfile.TemporaryDirectory() as d:
path = os.path.join(d, "state.json")
m = Maintenance(CFG, Store(path))
m.force_start(T0)
m.tick(T0, 11.0)
run(m, T0, 97, lambda i: 90.0 if i < 96 else 98.0) # 98 seen 1 min ago
run(m, T0 + 97 * MIN, 3, None) # SoC lost; state saved at once
t = T0 + 100 * MIN # restart 3 min after the loss, before the next 5 min save
m2 = Maintenance(CFG, Store(path))
r = m2.tick(t, None)
check("a fresh process reads charge, and still charges", m2.phase == CHARGE
and r.phase == CHARGE and r.charge_only)
check("...with the open minutes and the last SoC seen from the file",
m2._trk is not None and m2._trk["last"] == 98.0
and 92 <= m2._trk["open_min"] <= 105)
res, _, out, _ = run(m2, t + MIN, CHARGE_TIMEOUT_MIN, None, step=5)
check("...so the timeout counts from the first charge minute and, with the "
"last SoC 98, completes (no failure)",
out and out[0].phase == HOLD and out[0].failed == ""
and out[1] < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 60))
# drain: restart keeps it at 0 W and keeps the clock
path2 = os.path.join(d, "s2.json")
md = Maintenance(CFG, Store(path2))
md.force_start(T0)
md.tick(T0 + 100 * MIN, None)
md2 = Maintenance(CFG, Store(path2))
r = md2.tick(T0 + 101 * MIN, None)
check("a drain restarted with no SoC holds at 0 W", md2.phase == DRAIN
and r.setpoint_w == 0.0 and r.owns_setpoint)
res, _, out, _ = run(md2, T0 + 102 * MIN, DRAIN_TIMEOUT_MIN, None, step=5)
check("...and the 12 h clock is from the drain start, not the restart",
out and out[0].failed == "drain"
and out[1] <= T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN + 10))
# a charge restarted with no record of any SoC (old state file)
old = {"phase": "charge", "phase_started": (T0 - timedelta(hours=35)).isoformat(),
"last_completed": None, "last_start_attempt": None, "auto": True}
import json
path3 = os.path.join(d, "s3.json")
json.dump(old, open(path3, "w"))
mo = Maintenance(CFG, Store(path3))
res, _, out, _ = run(mo, T0, 120, None)
check("an old state file with no SoC seen: the charge fails at 36 h",
out and out[0].failed == "charge")
print("7. two packs")
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
a.force_start(T0)
b_alone = Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
same = True
for i in range(0, 120, 10):
t = T0 + i * MIN
plan = arbitrate([a, b], t)
ra = a.tick(t, None, blocked_by=plan[0])
rb = b.tick(t, 55.0, blocked_by=plan[1])
rb0 = b_alone.tick(t, 55.0, blocked_by=plan[1])
same = same and (rb.phase, rb.setpoint_w, rb.deferred) == \
(rb0.phase, rb0.setpoint_w, rb0.deferred)
check("A drains with no SoC at 0 W while B (SoC 55, idle) is as it is when A "
"is healthy", ra.setpoint_w == 0.0 and ra.owns_setpoint and rb.phase == IDLE
and rb.setpoint_w is None and not rb.owns_setpoint)
check("...B's answers are unchanged tick by tick", same)
res = None
for i in range(0, DRAIN_TIMEOUT_MIN + 30, 10):
t = T0 + 120 * MIN + i * MIN
plan = arbitrate([a, b], t)
res = a.tick(t, None, blocked_by=plan[0])
b.tick(t, 55.0, blocked_by=plan[1])
if res.failed:
break
check("A's drain times out and A backs off (A's keys only)",
res.failed == "drain" and a.store.get_time("last_failed") is not None
and b.store.get_time("last_failed") is None)
slot = (T0 + timedelta(days=1)).replace(hour=19, minute=5)
check("...then B, with its SoC, takes the slot as usual",
arbitrate([a, b], slot) == ["", ""] and b.wants_start(slot)
and not a.wants_start(slot))
b.force_start(slot)
rb = b.tick(slot + 5 * MIN, 50.0)
check("...and B's drain runs at the drain rate",
rb.phase == DRAIN and rb.setpoint_w == CFG.discharge_w)
# the other way: B charges with no SoC, A has a SoC
a = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
b = Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
b.force_start(T0)
b.tick(T0, 11.0)
run(b, T0, 5, 97.0)
a_alone = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
same, t = True, T0 + 10 * MIN
while t < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 30):
plan = arbitrate([a, b], t)
rb = b.tick(t, None, blocked_by=plan[1])
ra = a.tick(t, 60.0, blocked_by=plan[0])
ra0 = a_alone.tick(t, 60.0, blocked_by=plan[0])
same = same and (ra.phase, ra.setpoint_w, ra.deferred) == \
(ra0.phase, ra0.setpoint_w, ra0.deferred)
if rb.phase != CHARGE:
break
t += 5 * MIN
check("B charges with no SoC (last 97): A (SoC 60) is unchanged tick by tick",
same)
check("...B ends as done (HOLD), A untouched, no failure on either",
rb.phase == HOLD and rb.failed == ""
and b.store.get_time("last_failed") is None
and a.store.get_time("last_failed") is None and a.phase == IDLE)
print()
if fails:
print(f"{len(fails)} FAILED")
for f in fails:
print(" -", f)
sys.exit(1)
print("all passed")
+2 -1
View File
@@ -122,7 +122,8 @@ m = Maintenance(cfg, FakeStore())
m.force_start(t0)
r = m.tick(t0 + timedelta(minutes=5), soc=None)
check("no SoC: holds the phase rather than guessing", r.phase == DRAIN)
check("no SoC: still commands the drain rate", r.setpoint_w == 2500)
check("no SoC: MAINT-14 the drain holds at 0 W, never discharges",
r.owns_setpoint and r.setpoint_w == 0.0)
m = Maintenance(cfg, FakeStore())
m.store.set("phase", "banana")