Deploy 0.17.0 to master #186

Merged
admin merged 23 commits from deploy-0.17.0 into master 2026-10-11 01:37:02 +02:00
Owner

Deploy add-on 0.17.0 (release/1.0 merge e36565f, PR #185) to master.

Contents: SAFETY-103, MAINT-13, MAINT-14, SAFETY-107, MAINT-15. See goodwe_controller/CHANGELOG.md ## 0.17.0.

  • Owner go for deploy: 2026-10-11.
  • predeploy_check (--deployed-version 0.16.0) on fresh live options: to be run before merge.
  • Merge only after checks / unit (pull_request) is green on this head, pinning head_commit_id.

🤖 Generated with Claude Code

https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC

Deploy add-on 0.17.0 (release/1.0 merge e36565f, PR #185) to `master`. Contents: SAFETY-103, MAINT-13, MAINT-14, SAFETY-107, MAINT-15. See `goodwe_controller/CHANGELOG.md` `## 0.17.0`. - Owner go for deploy: 2026-10-11. - predeploy_check (`--deployed-version 0.16.0`) on fresh live options: to be run before merge. - Merge only after `checks / unit (pull_request)` is green on this head, pinning `head_commit_id`. 🤖 Generated with [Claude Code](https://claude.com/claude-code) https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
admin added 23 commits 2026-10-11 01:01:08 +02:00
SAFETY-103: no swing on old battery readings after a drain ends
checks / unit (pull_request) Failing after 35m9s
infra-pin / fresh (pull_request) Successful in 2s
138e45b53f
While a battery settles from its ended drain (SAFETY-95), the house point
was grid + every battery's reading. A register can be 10 s older than the
meter, so B swung 860 -> 1650 -> 870 W on A's old reading (rig check 5).

Now the house point is held and moved only as far as the meter proves:
each battery is between its last changed reading and its commands since
(a reading that changed this cycle, or a refused side, as it reads).
N=1 and 1 s registers are byte-identical to release/1.0.

DECISIONS/SAFETY-103-old-readings-after-a-drain.md, test_safety103.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-103: test a dropped battery is not counted; guard a read
checks / unit (pull_request) Successful in 34m26s
infra-pin / fresh (pull_request) Successful in 1s
98dd110a4f
Mutation M13 (a battery out of the split counted in the house point)
survived; a direct check now kills it. win[0] is read through a guard
(test_named_absence).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-103 review: correct the swing after a refusal or lost link in DECISIONS
checks / unit (pull_request) Successful in 34m52s
infra-pin / fresh (pull_request) Successful in 2s
c6f23a69d4
The test table gives 1.5 kW at N=2 and 3.9 kW summed at N=3 under a
surplus, and about 1 kW after a lost link without one; not 1.9 kW.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-13: a full pack that stops at 98-99 % is not a failed charge
checks / unit (pull_request) Successful in 34m21s
infra-pin / fresh (pull_request) Successful in 1s
28eff568b5
A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.

No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-13 round 2: gate open when nothing holds the charge back; safety93 scenario restored
checks / unit (pull_request) Failing after 34m45s
infra-pin / fresh (pull_request) Successful in 2s
6f05b2e4be
- gate_open is true with no price gate set up, in a cheap window, or while the
  pack is taking charge; the stall rule and timeout now work on a no-tariff site.
- reset the save timer on a phase change; exact 5 min gap-cap test.
- test_safety93: original timeout scenario kept (B finished) plus a case where a
  due B takes the slot after A's failure.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
MAINT-13 round 2: read the price gate without a new main.py option read
checks / unit (pull_request) Successful in 34m35s
infra-pin / fresh (pull_request) Successful in 1s
f7b83cc75c
test_static_tariff forbids main.py reading `static_profile`; a small
static_gated() in static_tariff.py answers it, and the Controller keeps the
answer in `_price_gated` beside `cheap`.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
MAINT-13 round 3: provider site, hourly fixed-tariff check, faster tests
checks / unit (pull_request) Successful in 34m52s
infra-pin / fresh (pull_request) Successful in 1s
6836f61bd4
- A price-provider site with no fixed tariff is not a gate (its plan never
  sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
  5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-13 review: tests for a stale charge record and a clock step back; DOCS names the 7 day end
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 34m49s
ea31289ec0
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-14: maintenance with no SoC reading: charge times out, drain holds at 0 W
checks / unit (pull_request) Successful in 35m13s
infra-pin / fresh (pull_request) Successful in 1s
f39e52efd3
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-14: accurate no-level wording per phase; name the limit that ended the charge
checks / unit (pull_request) Successful in 34m54s
infra-pin / fresh (pull_request) Successful in 1s
ef35f4b925
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-14 review: tests for a HOLD episode after a no-SoC charge, a MAINT-13 state file, and a true twin site at N=2
checks / unit (pull_request) Successful in 34m56s
infra-pin / fresh (pull_request) Successful in 1s
61a61941bb
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-107: a refusal held under another writer is learned once
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 2s
d12228d986
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
SAFETY-107 review: test a writer that turns round on a dead pack; say when rule 3 applies
checks / unit (pull_request) Successful in 35m22s
infra-pin / fresh (pull_request) Successful in 2s
848140c29f
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-15: the balancing hold ends on time with no SoC reading
checks / unit (pull_request) Successful in 35m22s
infra-pin / fresh (pull_request) Successful in 1s
cd1bf2a694
HOLD's time check moves into Maintenance._hold(), used by step() and
_no_soc(). A hold that loses its SoC now ends at hold_min, writes
last_completed and logs the same COMPLETE line. The 15 min HOLD line says
the hold still ends at its normal time. Behaviour with a reading is
unchanged (differential trace against db9e231).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
MAINT-15 round 2: in-repo differential check, full-hold with-reading check
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 1s
35b2a699de
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Reviewed at 35b2a69; CI run 1238 green.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Release 0.17.0
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 2s
35432ce065
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
REL-0.17.0 review: CHANGELOG wording fixes
checks / unit (pull_request) Successful in 35m16s
infra-pin / fresh (pull_request) Successful in 2s
808ec04dc4
SAFETY-107 row names the tested base; MAINT-17 says code reading only;
SAFETY-105 figure is from a simulation; SAFETY-97 edge is 175 W; the
maintenance note cites MAINT-14 and MAINT-15; SAFETY-108 "about 15 s".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Merge pull request #185: Release 0.17.0
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 1s
e36565fe39
admin merged commit 1b6f16dba2 into master 2026-10-11 01:37:02 +02:00