SAFETY-87 review: grade the three surviving review mutants
A battery refusing only to charge stays able; the reserve alarm is graded on the real limit, not the aim; 'control still runs' is set on the two peak rows only. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
@@ -656,6 +656,52 @@ check("⭐ a row that stops control outranks the running peak alarm: the "
|
||||
and "Meter down" in _both["banner"]
|
||||
and "until the alarm clears" in json.dumps(_both, ensure_ascii=False))
|
||||
|
||||
for _inv, _s, _r in zip(_ctl2.inverters, (15.0, 60.0), (0, -1)):
|
||||
_inv.soc, _inv.refused = _s, _r # B refuses only to CHARGE
|
||||
_chg = _ctl2._peak_on_able(_lim_all, [MaintResult(IDLE, False, None, False,
|
||||
[])] * 2)
|
||||
_ctl2.inverters[1].refused = 0
|
||||
check("⭐ a battery that refuses only to charge can still give: it stays "
|
||||
"able and carries the floor (2000 W of 2500 W)",
|
||||
not _chg.floor_limited and _chg.floor_w == 2000.0
|
||||
and _chg.able_w == 2500.0 and _chg.held == (A,))
|
||||
|
||||
|
||||
def _short_for(held_w, secs=30.0):
|
||||
"""`_reserve_short()` over `secs` of a steady quarter: the meter at
|
||||
`held_w` with the able batteries already at their full 2500 W."""
|
||||
s = types.SimpleNamespace(_reserve_batt_prev=None,
|
||||
_reserve_high_since=None,
|
||||
_peak_floor_limited=False, site_batt_w=2500.0)
|
||||
g = dataclasses.replace(_lim, floor_w=2500.0, able_w=2500.0)
|
||||
out = []
|
||||
for k in range(int(secs / 5.0) + 1):
|
||||
s._peak_proj = types.SimpleNamespace(
|
||||
block_start=rig.BASE, elapsed_s=450.0 + 5.0 * k,
|
||||
projected_w=held_w, held_w=held_w)
|
||||
out.append(Controller._reserve_short(s, g))
|
||||
return out
|
||||
|
||||
|
||||
_aim_miss, _limit_miss = _short_for(3480.0), _short_for(3600.0)
|
||||
check("⭐ the reserve alarm is graded on the real limit, not the aim: a "
|
||||
"quarter ending at 3480 W (over the 3450 W aim, under 3500 W) never "
|
||||
"alarms; one ending at 3600 W alarms once it holds ALARM_HOLD_S",
|
||||
not any(_aim_miss) and not any(_limit_miss[:2])
|
||||
and all(_limit_miss[2:]))
|
||||
|
||||
_runs_src = {}
|
||||
for _f in ("main.py", "homeview.py"):
|
||||
with open(os.path.join(HERE, "app", _f), encoding="utf-8") as _fh:
|
||||
_src = _fh.read()
|
||||
for _part in _src.split('out.append({')[1:]:
|
||||
if '"runs": True' in _part.split("})", 1)[0]:
|
||||
_runs_src.setdefault(_f, []).append(
|
||||
_part.split('"id": "', 1)[-1].split('"', 1)[0])
|
||||
check("⭐ 'control still runs' is set on the two peak rows only (saturated "
|
||||
"and reserve); no row that stops control carries it",
|
||||
_runs_src == {"main.py": ["peak_guard", "peak_guard"]})
|
||||
|
||||