SAFETY-129 round 3: the real reason for the 16 s limit, a slow-start check, the row's tail
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
03541a1eee
commit
c70eeb6916
@@ -33,9 +33,10 @@ inverter limit in its last seconds (OPT-34 rig F-2).
|
||||
16 new values in 60 s, so only a meter of about 3.5 s or faster: at 5 s
|
||||
it gave false delays. Late over 8 s. At a slower meter (a 5 s P1) the
|
||||
same fit runs over 120 s and calls only a delay over 16 s late, on 2 fits
|
||||
in a row, and never ends a verdict (SAFETY-129): a 10-12 s slow battery
|
||||
reads up to 15 s there, so 10 s late is not told from it, and it does not
|
||||
swing at 5 s.
|
||||
in a row, and never ends a verdict (SAFETY-129). Alone it reads 35-90 s on healthy
|
||||
runs, a few times in a row; only the slow-start and battery-fit check
|
||||
below keeps those from a verdict. 10 s late is not found: it cannot be
|
||||
told from a 10 s slow battery, and it does not swing at 5 s.
|
||||
- A meter fit says late only with evidence from the batteries' side too:
|
||||
a request more than 100 W from the battery reading took 3 s or more to
|
||||
move a reading towards it (`SLOW_START_S`; on time they start within
|
||||
@@ -71,7 +72,9 @@ The fits run all the time; the pull request has the counts.
|
||||
- Found 36-68 s after a lag starts at 1-2 s meters; at a 5 s meter 30 s late
|
||||
is found within 100 s after it starts (88 s measured) (the loop first moves 100 W after 60 s,
|
||||
SAFETY-129) with the export above -200 W, and 10 s late is not found. Until
|
||||
then control is as before.
|
||||
then control is as before. In a quiet house the "readings late" row stays
|
||||
about 2 minutes longer after the lag ends (126 s against 32 s on base); no
|
||||
harm measured, and it clears as early as on base when the load changes.
|
||||
- A battery that answers slowly is read as late readings and held: a dead
|
||||
time of 10 s or more (8 s reads 7-8; 10 s reads 10 at 1-2 s meters, 9 at
|
||||
5 s), or a 15-20 s lag (review round 2). The GoodWe measured settles in 6 s
|
||||
|
||||
@@ -174,8 +174,10 @@ M_SHARE, M_BETTER = 0.4, 0.7
|
||||
# SAFETY-129: a meter slower than that (a 5 s P1) has fewer than M_ROWS values
|
||||
# in M_FIT_S, so it is fitted over M_SLOW_FIT_S instead, from the same M_ROWS
|
||||
# values. It calls a delay late only over M_SLOW_LATE_S and on ON_FITS fits in
|
||||
# a row: the slow-battery runs (10-12 s dead time, R2-1) read up to 15 s at a
|
||||
# 5 s meter, and a 10 s lag cannot be told from them, nor does it swing.
|
||||
# a row. Alone it reads 35-90 s on healthy runs, a few times in a row; what
|
||||
# keeps those from a verdict is the slow-start and battery-fit check in
|
||||
# watch(), not the limit. A 10 s lag is not found: it cannot be told from a
|
||||
# slow battery (R2-1), nor does it swing at 5 s.
|
||||
M_SLOW_FIT_S = 120.0
|
||||
M_SLOW_LATE_S = 16.0
|
||||
# A meter fit counts only after an ask that took this long to start moving a
|
||||
|
||||
@@ -121,6 +121,15 @@ for dead in (8.0, 10.0):
|
||||
check(f"{dead:.0f} s dead time at a 5 s meter is not read as late "
|
||||
f"(R2-1 does not get worse)", secs == 0)
|
||||
|
||||
# At a 6 s meter an 8 s dead time reads late on the slow fit alone; only the
|
||||
# slow-start and battery-fit check keeps it from a verdict (122 s late
|
||||
# without the check, from 1 084 s).
|
||||
r, secs, first = run_late(house=owner, noise=80.0, units=AB, p1_s=6.0,
|
||||
dead_s=8.0, dur=1500.0)
|
||||
print(f" 8 s dead time, 6 s meter: late {secs} s")
|
||||
check("an 8 s dead time at a 6 s meter is never late (the slow fit needs an "
|
||||
"ask slow to start and no battery fit on time)", secs == 0)
|
||||
|
||||
# A 12 s dead time is already read as late (R2-1, SAFETY-128); the slow-meter
|
||||
# fit must not make that longer. The same run with the slow fit off is the
|
||||
# tree before this card.
|
||||
@@ -219,8 +228,8 @@ check("one late slow-meter fit is no fit; two in a row are one, and "
|
||||
check("the slow fit asks for a longer window and a later delay than the "
|
||||
"fast one", lateness.M_SLOW_FIT_S > lateness.M_FIT_S
|
||||
and lateness.M_SLOW_LATE_S > lateness.M_LATE_S)
|
||||
check("the slow fit's delay is above what a 10-12 s slow battery reads "
|
||||
"(R2-1: up to 15 s at a 5 s meter)", lateness.M_SLOW_LATE_S >= 16.0)
|
||||
check("the slow fit's late limit is above the fast one's and above a "
|
||||
"10 s lag", lateness.M_SLOW_LATE_S >= 16.0)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
|
||||
Reference in New Issue
Block a user