SAFETY-73: a battery that refuses, per inverter, with two or more
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R). A unit that gives < 100 W for 12 cycles in one direction while asked > 200 W, or trips its stale-reading gate on a ~0 W reading, gets a P_SAFETY `refused` unit limit closing that direction, so the allocator hands its share to the others within their own limits. Probe: a +-200 W pin every 15 min, one unit at a time, only while the site asks 200 W that way. All units refusing: the site law holds 0 W. Exits reseed the site target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above the configured cut-out; SAFETY-42/43 no longer report a refusing unit. N=1 unchanged. test_refusal_units.py: cases a/b/c on flat and jitter registers against the old behaviour, probes, recovery, exits; mutations U1-U13 all red. TEST-19 no-fault campaign: 0 engagements in 5280 runs. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
652097abde
commit
016ed5a5a3
@@ -0,0 +1,89 @@
|
||||
# SAFETY-73 - a battery that refuses, with two or more inverters
|
||||
|
||||
**Decided 2026-09-27 by the owner, on the phase A plan (option R). All four
|
||||
new questions answered yes. SAFETY-52's four decisions carry over.**
|
||||
|
||||
## The defect
|
||||
|
||||
SAFETY-52 held a refusing battery at 0 W at one inverter only. At N>1
|
||||
(`main.py` passed `refused=None`) nothing closed a unit that gives ~0 W while
|
||||
its state of charge reads above its configured cut-out, so the allocator kept
|
||||
handing it its weighted half. Measured on the real `Controller`, two units,
|
||||
house 3000 W, A cut out:
|
||||
|
||||
| register | law | B gives | grid | A's gate trips / h |
|
||||
|---|---|---|---|---|
|
||||
| flat -4 W | old | 533 W | +2471 W | 46 (each stops the whole site) |
|
||||
| flat -4 W | new | 2000 W (its rating) | +1004 W | 1 |
|
||||
| jitter | old | 1910 W | +1094 W | 0 |
|
||||
| jitter | new | 2000 W | +1004 W | 0 |
|
||||
|
||||
House 1200 W, which B alone carries: old +671 W (flat) and +284 W (jitter)
|
||||
standing import, new -16 W. Both cut out: old keeps asking two empty batteries
|
||||
(+1910 W each on the jitter shape), new holds the site at 0 W.
|
||||
|
||||
## What was decided
|
||||
|
||||
1. **A refusing unit is closed in that direction** by its own P_SAFETY unit
|
||||
claim, source `refused`. It engages when the unit gives under
|
||||
`REFUSED_BELOW_W` (100 W) for `SETTLE_CYCLES` (12) cycles in one direction
|
||||
while asked more than `PROBE_W` (200 W), or when its stale-reading gate
|
||||
trips on a held reading under 100 W. The allocator then hands its share to
|
||||
the others within their own limits (owner decision 1). It is a hard unit
|
||||
limit that always intersects, so OPT-11's P_MODE layer fits inside it.
|
||||
2. **It binds every strategy's ask on that unit** (decision 2): peak guard,
|
||||
arbitrage and maintenance are placed around it like the loop.
|
||||
3. **A refusal above the configured cut-out** logs INFO plus one WARNING ending
|
||||
in `REFUSES_ABOVE_CUT_OUT` (decision 3). SAFETY-42/43 no longer report such a
|
||||
unit: its share is 0 W, and `account()` treats it as parked.
|
||||
4. **All units refusing the same way** pass that sign to `compute()`, so the
|
||||
site holds 0 W with SAFETY-52's law (decision 4). Probes go one unit at a
|
||||
time.
|
||||
5. **Probe:** every 15 min for 34 s the claim becomes a pin at +-200 W and the
|
||||
others carry the rest. The pin stands only while the resolved site target
|
||||
asks at least 200 W its way; otherwise it would make a sibling take the
|
||||
opposite direction, so it falls back to the closed limit for that cycle.
|
||||
6. **Exits:** a reading of 100 W or more in the held direction (probe or not);
|
||||
100 W or more taken the other way for 12 cycles (charge at the floor; one
|
||||
cycle of the loop overshooting through zero is not enough); stop or start.
|
||||
On every exit the site target and integrator restart from the watts on the
|
||||
wire, or the reopened unit is handed a parked remainder at once.
|
||||
|
||||
**Why 200 W and not `saturation_w`.** A unit's share is often small: a 400 W
|
||||
night load split two ways asks 200 W of each. With 500 W the empty battery
|
||||
kept a phantom share that SAFETY-43's relative arm then reported as not
|
||||
delivering, the ERROR decision 3 replaces. Shares of 200 W or less that give
|
||||
under 100 W are "too small to call" in `account()`: the sibling covers the
|
||||
meter and nothing is asked of the empty battery that matters.
|
||||
|
||||
**Why one direction throughout.** On TEST-19's flapping family a command that
|
||||
swaps sign each cycle reads ~0 through the plant's lag: 42 engagements in 21
|
||||
no-fault runs without the rule, 0 with it.
|
||||
|
||||
**N=1 is unchanged.** Every SAFETY-73 path is gated on `len(inverters) > 1`.
|
||||
`test_refusal_units.py` part 6 runs SAFETY-52's whole suite with every
|
||||
SAFETY-73 method made to raise.
|
||||
|
||||
## Evidence
|
||||
|
||||
- `test_refusal_units.py`: cases a, b and c on both register shapes against
|
||||
the old behaviour, probes and their spacing, one-at-a-time probing, the
|
||||
recovery reseed, each exit, the small-ask and small-site-target cases, the
|
||||
WARNING, the status row and shadow mode. Mutations U1-U13 in its docstring.
|
||||
- **No false engagements.** TEST-19's no-fault campaign (admin/goodwe
|
||||
`sim/delivery_window.py` families, 2640 runs at N=2 and 2640 at N=1, every
|
||||
unit executing its share) graded with the engage clause: 0 engagements, the
|
||||
longest qualifying streak 5 cycles against 12. The grader is
|
||||
`goodwe-session/scratch_s73/s73_nofault.py`.
|
||||
- **Recovery.** Case a, A recovering into a house that fell below the parked
|
||||
target: worst grid +0 W with the reseed. Phase A measured -1059 W without the
|
||||
reseed and the site hold.
|
||||
|
||||
## Not covered
|
||||
|
||||
- A unit that gives a steady part of its ask (100 W or more) is a limit, as at
|
||||
N=1. SAFETY-42/43 still report it.
|
||||
- `pack_permissions` stays SoC-based, so the peak guard may size a shave with a
|
||||
refusing battery counted. The shortfall shows as `unmet_w`.
|
||||
- A wedged unit (HW-01) reading ~0 W is now shown as a refusal, not reported as
|
||||
not delivering. Its share still moves, which is the gain SAFETY-42 measured.
|
||||
@@ -295,7 +295,7 @@ When the add-on refuses to start, each reason names the setting by its label and
|
||||
- **Stuck meter alarm after** (`meter_freeze_s`): measured, not chosen (SAFETY-18). Over 2399 s of this house at its operating point, the longest run without a new reading is 15.4 s, and 300 s is 19.5 times that. It raises an alarm only and does not set 0 W.
|
||||
- **Opposing inverters threshold** (`circulation_w`): measured on 924 closed-loop test runs (SAFETY-31). The worst legitimate opposition drops from 505 s at 100 W to 5 s at 400 W, the lowest value accepted. 700 W is 1.75 times that knee, with margin because the second inverter is still a copy of the first.
|
||||
- **Opposing inverters time** (`circulation_hold_s`): derived (SAFETY-31). 75 s is fifteen control cycles, 15 times the worst legitimate episode, and 2.5 times the control board's 30 s link limit.
|
||||
- **Not delivering alarm after** (`delivery_hold_s`): two or more inverters only. It reports only (SAFETY-42): nothing is commanded differently. Derived from 2640 closed-loop test runs with nothing faulty. The worst legitimate episode is 35.0 s and 185 s is 5.29 times that. The schema allows 30 s, below that, so expect false reports there. A battery at or below its own cut-out level is never reported. Re-derive with admin/goodwe `sim/delivery_window.py --campaign --blag`.
|
||||
- **Not delivering alarm after** (`delivery_hold_s`): two or more inverters only. It reports only (SAFETY-42): nothing is commanded differently. Derived from 2640 closed-loop test runs with nothing faulty. The worst legitimate episode is 35.0 s and 185 s is 5.29 times that. The schema allows 30 s, below that, so expect false reports there. A battery at or below its own cut-out level is never reported, and neither is one that gives under 100 W (SAFETY-73: it is a battery that refuses). Re-derive with admin/goodwe `sim/delivery_window.py --campaign --blag`.
|
||||
- **Shadow mode** (`shadow_mode`): the whole decision path runs and nothing reaches the inverter. The status page and action log show what would have been sent. A safety stop that is already up stays up. See [Shadow mode](#shadow-mode-shadow_mode).
|
||||
- **Control gain** (`gain`): measured on real hardware and already at the limit.
|
||||
- **Largest change per cycle** (`slew_w`): 0 means follow the rating: about a ninth of it, derived (SAFETY-39) from a measured ~18 s step response against a 2 s meter tick. A fixed value faster than the rating allows is refused. At 1000 W against a 5000 W rating control swung the meter from 3.4 kW export to 2.8 kW import on 2026-09-05.
|
||||
@@ -550,15 +550,23 @@ control is stopped or started. 200 W is below the 250 W the stale-reading check
|
||||
needs, so a test never trips it. A battery that gives some power, even 100 W,
|
||||
is not refusing and keeps its request.
|
||||
|
||||
⚠️ **One inverter only.** With several inverters this hold is off. There, the
|
||||
battery level limit moves an empty battery's share to the others, but only if
|
||||
its “Battery cut-out level” matches where the battery really stops. A battery
|
||||
that refuses at another level, or for another reason (cold, a battery fault),
|
||||
can still hold its last request until the grid starts to export.
|
||||
**With two or more inverters** the same rule works per inverter. An inverter
|
||||
whose battery gives less than 100 W for 12 cycles while asked for more than
|
||||
200 W is asked 0 W, and the other inverters take over its share, each up to
|
||||
its own limits. The status page names it: *inverter-a: the battery refuses to
|
||||
give power, the others take over*. It is tested at 200 W every 15 minutes, one
|
||||
inverter at a time, and only while the site asks at least 200 W that way.
|
||||
It still accepts charge, and a minute of charging ends the refusal. When every
|
||||
inverter refuses the same way, the whole site asks 0 W as with one inverter.
|
||||
If the battery refuses while its level reads above its “Battery cut-out level”,
|
||||
the log adds one warning ending in `REFUSES_ABOVE_CUT_OUT`: check that setting.
|
||||
A battery that refuses is not reported as *not delivering*.
|
||||
|
||||
*For installers:* SAFETY-52. The event log reads `BATTERY REFUSES …` and
|
||||
`BATTERY REFUSES ENDED: …`, and the INFO line ends in `BATTERY_REFUSES`.
|
||||
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures.
|
||||
*For installers:* SAFETY-52 and SAFETY-73. The event log reads
|
||||
`BATTERY REFUSES …` and `BATTERY REFUSES ENDED …` (with the inverter's name at
|
||||
N>1), and the INFO line ends in `BATTERY_REFUSES`.
|
||||
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures and
|
||||
`DECISIONS/SAFETY-73-refusal-per-inverter.md` the two-inverter ones.
|
||||
|
||||
⚠️ **`Loop reason` is not the `Why` row on the status page, and the two will
|
||||
often disagree.** `Why` is the *arbiter's* answer in words — *Keeping the grid
|
||||
|
||||
@@ -226,6 +226,12 @@ CLAIM_SCOPE = {
|
||||
# reaches the allocator, so a unit-scoped claim is the shape that sentence
|
||||
# asks for rather than an evasion of it.
|
||||
"pack": SCOPE_UNIT,
|
||||
# main.py: `Claim.limit("refused", P_SAFETY, ...)` and, during a probe,
|
||||
# `Claim.set("refused", P_SAFETY, +-PROBE_W)`. SAFETY-73: THIS battery gives
|
||||
# nothing in one direction, measured on THIS unit's own reading. A hard unit
|
||||
# limit that always intersects, so the share goes to the siblings. Filed at
|
||||
# N>1 only; at N=1 SAFETY-52's law in compute() does the same job.
|
||||
"refused": SCOPE_UNIT,
|
||||
# main.py: `Claim.set("maintenance", P_MAINTENANCE, ...)` when the cycle owns
|
||||
# the setpoint, and `Claim.limit("maintenance", P_MAINT_SHAPE, hi=...)` when
|
||||
# it only shapes. §12's monthly recalibration is a PACK procedure - drain
|
||||
|
||||
@@ -317,6 +317,16 @@ class Inverter:
|
||||
tripped=bool(data.get(self.key("delivery_tripped"), False)),
|
||||
reason=str(data.get(self.key("delivery_reason"), "") or ""))
|
||||
|
||||
# SAFETY-73. The direction this unit's battery refuses (+1 give, -1
|
||||
# take, 0 none), when that refusal or its last probe started, the
|
||||
# current probe's start, and the cycles of evidence so far. Memory
|
||||
# only, like SAFETY-52's: stop and start end it. Used at N>1 only.
|
||||
self.refused = 0
|
||||
self.refused_at = None
|
||||
self.probe_from = None
|
||||
self.ref_count = 0
|
||||
self.ref_sign = 0
|
||||
|
||||
# -- store ---------------------------------------------------------------
|
||||
def key(self, name: str) -> str:
|
||||
"""This unit's namespaced Store key for `name`. See store.unit_key()."""
|
||||
@@ -411,6 +421,13 @@ class Inverter:
|
||||
return (messages.row_battery_stuck(self.name) if self.batt_fresh.stale
|
||||
else "")
|
||||
|
||||
def refusal_note(self) -> str:
|
||||
"""SAFETY-73's status row while this unit's battery refuses."""
|
||||
if not self.refused:
|
||||
return ""
|
||||
return messages.row_battery_refuses(self.name, self.refused,
|
||||
self.probe_from is not None)
|
||||
|
||||
def link_note(self, now: datetime) -> str:
|
||||
"""One line for the status page. Empty when there is nothing to say.
|
||||
|
||||
|
||||
@@ -28,6 +28,7 @@ import contextlib
|
||||
import functools
|
||||
import json
|
||||
import logging
|
||||
import math
|
||||
import signal
|
||||
import time
|
||||
from datetime import datetime, timedelta, timezone
|
||||
@@ -234,6 +235,11 @@ def pack_energy_of(inv):
|
||||
inv.capacity_kwh, inv.max_w)
|
||||
|
||||
|
||||
def _refused_interval(sign: int) -> tuple:
|
||||
"""SAFETY-73: the (lo, hi) a refusing unit may be asked: 0 W that way."""
|
||||
return (-math.inf, 0.0) if sign > 0 else (0.0, math.inf)
|
||||
|
||||
|
||||
def why_key(winner: str, claims) -> str:
|
||||
"""The key of `messages.WHY_WINNER` for a resolution's winner.
|
||||
|
||||
@@ -1121,6 +1127,19 @@ class Controller:
|
||||
"""
|
||||
t = self.tuning
|
||||
standing = inv.standing_w()
|
||||
if len(self.inverters) > 1:
|
||||
# SAFETY-73: at N>1 the same trip refuses THIS unit only.
|
||||
if ((self.auto or self.shadow) and not inv.refused
|
||||
and inv.ref_count >= t.saturation_cycles
|
||||
and inv.batt_fresh.held is not None
|
||||
and abs(inv.batt_fresh.held) < _ctl.REFUSED_BELOW_W
|
||||
and abs(standing) > _ctl.PROBE_W):
|
||||
self._now_mono = now_mono
|
||||
self._unit_refusal_start(
|
||||
inv, 1 if standing > 0 else -1,
|
||||
f"stale reading {inv.batt_fresh.held:+.0f} W while asked "
|
||||
f"{standing:+.0f} W")
|
||||
return
|
||||
if (len(self.inverters) == 1 and (self.auto or self.shadow)
|
||||
and not self.batt_refused
|
||||
and self.sat_count >= t.saturation_cycles
|
||||
@@ -1132,6 +1151,111 @@ class Controller:
|
||||
f"stale reading {inv.batt_fresh.held:+.0f} W "
|
||||
f"while asked {standing:+.0f} W")
|
||||
|
||||
# --- SAFETY-73: the same refusal, per inverter, at N>1 -------------------
|
||||
# SAFETY-52's decisions applied to one unit of several: a unit that gives
|
||||
# < REFUSED_BELOW_W for SETTLE_CYCLES while asked > PROBE_W is closed in
|
||||
# that direction by a P_SAFETY unit limit, so the allocator hands its share
|
||||
# to the others; it is probed at PROBE_W every PROBE_EVERY_S, one unit at a
|
||||
# time. The ask is PROBE_W, not `saturation_w`: a unit's share is often
|
||||
# small (a 400 W night load split two ways) and SAFETY-43 would otherwise
|
||||
# name the empty battery as not delivering. DECISIONS/SAFETY-73.
|
||||
def _unit_refusal_start(self, inv, sign: int, evidence: str) -> None:
|
||||
inv.refused, inv.refused_at = sign, self._now_mono
|
||||
inv.probe_from, inv.ref_count = None, 0
|
||||
self.log_event(f"BATTERY REFUSES {inv.name}: {evidence}",
|
||||
hint=messages.hint("unit_refuses", unit=inv.name))
|
||||
_LOG.info("%s: the battery refuses power, so it is asked 0 W and the "
|
||||
"other inverters take over: BATTERY_REFUSES.", inv.name)
|
||||
_LOG.debug("Evidence for %s: BATTERY_REFUSES: %s.", inv.name, evidence)
|
||||
if (inv.soc is not None and inv.bms_soc_floor is not None
|
||||
and float(inv.soc) > float(inv.bms_soc_floor)):
|
||||
# Owner decision 3: a refusal above the configured cut-out level
|
||||
# may mean that level is set wrong. One line, no safety stop.
|
||||
_LOG.warning("%s refuses power above its battery cut-out level, "
|
||||
"check its cut-out level: REFUSES_ABOVE_CUT_OUT.",
|
||||
inv.name)
|
||||
_LOG.debug("Evidence for %s: REFUSES_ABOVE_CUT_OUT: battery level "
|
||||
"%.0f %%, cut-out level %.0f %%.", inv.name,
|
||||
float(inv.soc), float(inv.bms_soc_floor))
|
||||
|
||||
def _unit_refusal_end(self, inv, why: str) -> None:
|
||||
if not inv.refused:
|
||||
return
|
||||
inv.refused, inv.refused_at, inv.probe_from = 0, None, None
|
||||
inv.ref_count = 0
|
||||
self.log_event(f"BATTERY REFUSES ENDED {inv.name}: {why}",
|
||||
hint=messages.hint("unit_gives", unit=inv.name))
|
||||
_LOG.info("%s: the battery refusal ends, it is asked for power again: "
|
||||
"%s.", inv.name, why)
|
||||
# The site target may stand above what was placed (the refused share
|
||||
# was unmet). Restart it from the watts on the wire, or the reopened
|
||||
# unit is handed the parked remainder at once (phase A: -1059 W).
|
||||
placed = float(sum(i.standing_w() for i in self.inverters))
|
||||
self.target = self.i_w = placed
|
||||
self.sat_count = 0
|
||||
|
||||
def _unit_probe(self, inv) -> bool:
|
||||
"""True while `inv` may try PROBE_W. One unit probes at a time."""
|
||||
now = self._now_mono
|
||||
if not inv.refused or inv.refused_at is None or now is None:
|
||||
return False
|
||||
if inv.probe_from is not None:
|
||||
if now - inv.probe_from < _ctl.PROBE_S:
|
||||
return True
|
||||
inv.probe_from, inv.refused_at = None, now
|
||||
return False
|
||||
if now - inv.refused_at < _ctl.PROBE_EVERY_S or any(
|
||||
i.probe_from is not None for i in self.inverters):
|
||||
return False
|
||||
inv.probe_from = now
|
||||
return True
|
||||
|
||||
def _unit_refusals(self) -> None:
|
||||
"""Engage and end each unit's refusal from its own reading."""
|
||||
for inv in self.inverters:
|
||||
b = inv.batt
|
||||
if inv.refused:
|
||||
if b is not None and inv.refused * b >= _ctl.PROBE_ANSWER_W:
|
||||
self._unit_refusal_end(
|
||||
inv, "the probe was answered"
|
||||
if inv.probe_from is not None
|
||||
else "the battery gives power")
|
||||
continue
|
||||
# The other direction: the battery takes PROBE_ANSWER_W or more
|
||||
# the other way (charge at the floor) for SETTLE_CYCLES. Counted
|
||||
# on its own reading, so one cycle of the loop overshooting
|
||||
# through zero does not hand it its share back.
|
||||
inv.ref_count = (inv.ref_count + 1 if b is not None and
|
||||
-inv.refused * b >= _ctl.PROBE_ANSWER_W else 0)
|
||||
if inv.ref_count >= _ctl.SETTLE_CYCLES:
|
||||
self._unit_refusal_end(
|
||||
inv, "the battery takes power the other way")
|
||||
continue
|
||||
if b is None:
|
||||
continue # a gap keeps the count: the gate's trip seeds
|
||||
standing = inv.standing_w()
|
||||
sign = 1 if standing > 0 else -1
|
||||
# One direction throughout: a command that swaps sign every cycle
|
||||
# (a flapping load) reads ~0 through the plant's own lag, and that
|
||||
# is a battery following, not refusing (TEST-19 flapping family).
|
||||
if abs(standing) > _ctl.PROBE_W and abs(b) < _ctl.REFUSED_BELOW_W:
|
||||
inv.ref_count = (min(inv.ref_count + 1, _ctl.SETTLE_CYCLES)
|
||||
if sign == inv.ref_sign else 1)
|
||||
else:
|
||||
inv.ref_count = 0
|
||||
inv.ref_sign = sign
|
||||
if inv.ref_count >= _ctl.SETTLE_CYCLES:
|
||||
self._unit_refusal_start(
|
||||
inv, sign,
|
||||
f"asked {standing:+.0f} W, the battery gave {b:+.0f} W "
|
||||
f"for {_ctl.SETTLE_CYCLES} cycles")
|
||||
|
||||
def _site_refused(self):
|
||||
"""Owner decision 4: every unit refuses the same way, so the site law
|
||||
holds 0 W (SAFETY-52's, in compute()). Otherwise None, the old law."""
|
||||
signs = {inv.refused for inv in self.inverters}
|
||||
return signs.pop() if len(signs) == 1 and 0 not in signs else None
|
||||
|
||||
def log_event(self, msg: str, hint: str | None = None) -> None:
|
||||
"""`msg` goes on the action log, the add-on's own technical record.
|
||||
`hint` is `messages.hint()`'s plain words for the same event, and is
|
||||
@@ -2516,7 +2640,8 @@ class Controller:
|
||||
now = datetime.now(timezone.utc)
|
||||
return [n for n in
|
||||
[x for inv in self.inverters
|
||||
for x in (inv.link_note(now), inv.stale_note())]
|
||||
for x in (inv.link_note(now), inv.stale_note(),
|
||||
inv.refusal_note())]
|
||||
if n]
|
||||
|
||||
async def cycle(self) -> None:
|
||||
@@ -2810,7 +2935,13 @@ class Controller:
|
||||
# what part 6 grades instead is that WIDENING the window
|
||||
# changes the answer.
|
||||
live=inv.is_live(now)[0],
|
||||
parked=inv.sign_wd.tripped,
|
||||
# SAFETY-73: a refusing unit is asked 0 W on purpose, and
|
||||
# one asked under PROBE_W that gives under 100 W is a
|
||||
# refusal too small to call (its sibling covers the meter).
|
||||
parked=inv.sign_wd.tripped or bool(inv.refused) or (
|
||||
n_units > 1 and inv.batt is not None
|
||||
and abs(float(standing[inv.name])) <= _ctl.PROBE_W
|
||||
and abs(float(inv.batt)) < _ctl.REFUSED_BELOW_W),
|
||||
# ⚠️ THIS UNIT'S OWN CUT-OUT. Not the shipped 10 %, and not
|
||||
# the site's `peak_soc_floor` either - that one bounds a
|
||||
# money-saving discharge only, and grading a pack against it
|
||||
@@ -3422,6 +3553,16 @@ class Controller:
|
||||
self._refusal_auto = bool(self.auto)
|
||||
self._refusal_end("control started" if self.auto
|
||||
else "control stopped")
|
||||
for inv in (self.inverters if len(self.inverters) > 1 else ()):
|
||||
self._unit_refusal_end(inv, "control started" if self.auto
|
||||
else "control stopped")
|
||||
# SAFETY-73: each unit's own refusal, engaged and ended on its own
|
||||
# reading, before the loop reads `self.target` (an end reseeds it).
|
||||
_probing = {}
|
||||
if len(self.inverters) > 1 and self.inputs_ok:
|
||||
self._unit_refusals()
|
||||
_probing = {inv.name: self._unit_probe(inv)
|
||||
for inv in self.inverters if inv.refused}
|
||||
if (self.auto or self.shadow) and self.inputs_ok:
|
||||
# ⚠️ prev is the ARBITER's last output, not the loop's own last
|
||||
# wish. If something outranked the loop, that is what the hardware
|
||||
@@ -3446,6 +3587,8 @@ class Controller:
|
||||
if self.loop_w is not None and self.target != self.loop_w:
|
||||
self._refusal_end("another writer")
|
||||
probe = self._refusal_probe()
|
||||
if len(self.inverters) > 1:
|
||||
probe = any(_probing.values())
|
||||
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
|
||||
# The anti-windup test inside compute() is
|
||||
# `abs(prev_w - actual_w) > saturation_w`, and `prev_w` is the SITE
|
||||
@@ -3476,7 +3619,10 @@ class Controller:
|
||||
i_w=self.i_w,
|
||||
# SAFETY-52 at one inverter only: with several, OPT-09's pack
|
||||
# limit already closes an empty battery's discharge end.
|
||||
refused=self.batt_refused if len(self.inverters) == 1 else None,
|
||||
# SAFETY-73: at N>1 the site law holds 0 W only while every
|
||||
# unit refuses the same way. Otherwise None, the old law.
|
||||
refused=self.batt_refused if len(self.inverters) == 1
|
||||
else self._site_refused(),
|
||||
probe=probe,
|
||||
)
|
||||
if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
|
||||
@@ -3486,7 +3632,8 @@ class Controller:
|
||||
self.sat_count = decision.sat_count
|
||||
self.i_w = decision.i_w
|
||||
self.loop_w = decision.target_w
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe)
|
||||
if len(self.inverters) == 1:
|
||||
self._refusal_update(decision, loop_prev, site_batt, probe)
|
||||
# --- TEL-10 ------------------------------------------------------
|
||||
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
|
||||
# THE CARD IS. `self.i_w` is carried between cycles and published
|
||||
@@ -3585,8 +3732,44 @@ class Controller:
|
||||
# ability to DELIVER rests on this argument - a weight cannot stop a
|
||||
# unit being commanded and cannot move a failing unit's load to its
|
||||
# sibling. The `pack` claim filed above is the half that constrains.
|
||||
resolution = resolve(claims, units=self.units, live=self.live_units(),
|
||||
weights=self.pack_weights, tick=self.alloc_tick)
|
||||
# --- SAFETY-73: each refusing unit's own P_SAFETY claim ---------------
|
||||
# A hard unit limit that always intersects (OPT-11's P_MODE layer sits
|
||||
# inside it): closed in the refused direction, so the allocator hands
|
||||
# the share to the others within their own limits. During its probe it
|
||||
# is a pin at PROBE_W and the others carry the rest.
|
||||
for inv in self.inverters:
|
||||
if not inv.refused:
|
||||
continue
|
||||
if _probing.get(inv.name):
|
||||
claims.append(Claim.set("refused", P_SAFETY,
|
||||
inv.refused * _ctl.PROBE_W,
|
||||
_ctl.PROBING,
|
||||
actuator=self.actuator_of("refused",
|
||||
inv)))
|
||||
else:
|
||||
claims.append(Claim.limit("refused", P_SAFETY,
|
||||
*_refused_interval(inv.refused),
|
||||
_ctl.REFUSED,
|
||||
actuator=self.actuator_of("refused",
|
||||
inv)))
|
||||
_live = self.live_units()
|
||||
while True:
|
||||
resolution = resolve(claims, units=self.units, live=_live,
|
||||
weights=self.pack_weights, tick=self.alloc_tick)
|
||||
# SAFETY-73: a probe pin stands only while the resolved site target
|
||||
# asks at least PROBE_W its way. Below that a sibling would carry
|
||||
# the opposite direction (circulation), so the pin goes back to the
|
||||
# closed limit and the split is resolved once more.
|
||||
_void = [k for k, c in enumerate(claims)
|
||||
if c.source == "refused" and c.kind == "set"
|
||||
and c.value * resolution.target_w < _ctl.PROBE_W ** 2]
|
||||
if not _void:
|
||||
break
|
||||
for k in _void:
|
||||
claims[k] = Claim.limit(
|
||||
"refused", P_SAFETY,
|
||||
*_refused_interval(1 if claims[k].value > 0 else -1),
|
||||
_ctl.REFUSED, actuator=claims[k].actuator)
|
||||
self.allocation = resolution.allocation
|
||||
# --- THE TWO REFUSALS, AND THEY ARE NOT THE SAME REFUSAL --------------
|
||||
# Both do the same thing - REPLACE the resolution with a 0 W failsafe
|
||||
@@ -5114,7 +5297,8 @@ class Controller:
|
||||
_now = datetime.now(timezone.utc)
|
||||
for inv in self.inverters:
|
||||
for note, red in ((inv.link_note(_now), not inv.is_live(_now)[0]),
|
||||
(inv.stale_note(), False)):
|
||||
(inv.stale_note(), False),
|
||||
(inv.refusal_note(), False)):
|
||||
if note:
|
||||
out.append({"ok": False, "warn": not red, "text": note})
|
||||
|
||||
|
||||
@@ -786,6 +786,14 @@ def row_battery_stuck(unit) -> str:
|
||||
f"for now")
|
||||
|
||||
|
||||
def row_battery_refuses(unit, sign, probing) -> str:
|
||||
"""SAFETY-73. One inverter's battery refuses, the others take its share."""
|
||||
way = "give" if sign > 0 else "take"
|
||||
if probing:
|
||||
return f"{unit}: testing if the battery will {way} power again"
|
||||
return f"{unit}: the battery refuses to {way} power, the others take over"
|
||||
|
||||
|
||||
# The top of the page: why the battery does what it does (the "Why" line).
|
||||
WHY_WINNER = {
|
||||
"loop": "Keeping the grid near zero",
|
||||
@@ -805,6 +813,8 @@ WHY_WINNER = {
|
||||
# SAFETY-52: the loop's two words for a battery that gives nothing.
|
||||
"battery refuses": "The battery refuses to give power",
|
||||
"battery probe": "Testing if the battery gives power again",
|
||||
# SAFETY-73: a refusing inverter's own claim, closed or probing.
|
||||
"refused": "A battery refuses power, the others take over",
|
||||
}
|
||||
WHY_LIMIT = {
|
||||
"peak(quarter peak)": "the peak limit",
|
||||
@@ -815,6 +825,7 @@ WHY_LIMIT = {
|
||||
"pack": "the battery level",
|
||||
"reserve": "the battery reserve",
|
||||
"maintenance": "battery maintenance",
|
||||
"refused": "a battery that refuses power",
|
||||
}
|
||||
|
||||
|
||||
@@ -857,6 +868,8 @@ HINTS = {
|
||||
"battery_back": "{unit}: battery power reading is used again",
|
||||
"battery_refuses": "The battery refuses to give power, the add-on asks 0 W",
|
||||
"battery_gives": "The battery refusal ended, control asks for power again",
|
||||
"unit_refuses": "{unit}: the battery refuses power, the others take over",
|
||||
"unit_gives": "{unit}: the battery refusal ended, it is asked for power again",
|
||||
"bad_value": "The add-on made an invalid power value, inverters set to 0 W",
|
||||
"write_blocked": "{unit}: a power request was blocked, it is set to 0 W",
|
||||
"all_blocked": "A power request was blocked, inverters set to 0 W",
|
||||
@@ -1027,6 +1040,12 @@ def status_samples() -> list:
|
||||
("row_peak_guard_on", AMBER, row_peak_guard_on(1200, 2500,
|
||||
shadow=True)),
|
||||
("row_battery_stuck", AMBER, row_battery_stuck("inverter-b")),
|
||||
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
|
||||
False)),
|
||||
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", -1,
|
||||
False)),
|
||||
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
|
||||
True)),
|
||||
("row_circulating_check", GREEN, row_circulating_check(0, 0, 60)),
|
||||
]
|
||||
|
||||
|
||||
@@ -149,7 +149,7 @@ check("...and `source` is still the first positional argument, which is what "
|
||||
Claim.limit("device", P_SAFETY, -1, 1).source == "device")
|
||||
|
||||
print()
|
||||
print("ARB-03 2. the split: eleven sources, each classified where it is BUILT")
|
||||
print("ARB-03 2. the split: twelve sources, each classified where it is BUILT")
|
||||
# The classification is graded against what each claim is ABOUT, restated here
|
||||
# so that the table in arbiter.py and the expectation in a test are not the same
|
||||
# sentence read twice. test_peakguard.py part 10f pins this set against main.py's
|
||||
@@ -189,16 +189,20 @@ UNIT_SOURCES = {
|
||||
"is added, `peak_soc_floor` is not consulted, the SITE target "
|
||||
"is untouched, and main.py does not file it at all at a "
|
||||
"roster of one",
|
||||
# SAFETY-73.
|
||||
"refused": "THIS battery's own reading gave nothing against THIS unit's "
|
||||
"own standing command, so that direction is closed on THIS "
|
||||
"unit and its share goes to the others. Filed at N>1 only",
|
||||
}
|
||||
for _src, _why in sorted(SITE_SOURCES.items()):
|
||||
print(f" site {_src:<11} {_why}")
|
||||
for _src, _why in sorted(UNIT_SOURCES.items()):
|
||||
print(f" unit {_src:<11} {_why}")
|
||||
check("all ELEVEN claim sources are classified, and only those eleven",
|
||||
check("all TWELVE claim sources are classified, and only those twelve",
|
||||
set(CLAIM_SCOPE) == set(SITE_SOURCES) | set(UNIT_SOURCES))
|
||||
check("the six that are about the GRID CONNECTION are site claims",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE} == set(SITE_SOURCES))
|
||||
check("the five that are about a PACK, a DEVICE or one write are per-inverter",
|
||||
check("the six that are about a PACK, a DEVICE or one write are per-inverter",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT} == set(UNIT_SOURCES))
|
||||
check("a source nobody classified cannot be routed at all - actuator_for() "
|
||||
"raises rather than defaulting to the site, because defaulting to the "
|
||||
@@ -216,7 +220,7 @@ check("with one inverter every source routes to the site, per-inverter ones "
|
||||
all(actuator_for(s, "inverter-a", ONE) == ACTUATOR_SITE for s in CLAIM_SCOPE))
|
||||
check("...and with none configured at all, likewise",
|
||||
all(actuator_for(s, "inverter-a", ()) == ACTUATOR_SITE for s in CLAIM_SCOPE))
|
||||
check("with TWO the identity breaks and the split becomes real: the five "
|
||||
check("with TWO the identity breaks and the split becomes real: the six "
|
||||
"per-inverter sources route to the unit this controller drives, the six "
|
||||
"site sources stay on the grid connection",
|
||||
{s: actuator_for(s, "inverter-a", TWO) for s in CLAIM_SCOPE}
|
||||
|
||||
@@ -33,7 +33,7 @@ from datetime import datetime, timedelta, timezone
|
||||
|
||||
from named_absence import given, present
|
||||
|
||||
from app import messages
|
||||
from app import control, messages
|
||||
from app.control import Tuning
|
||||
from app.delivery import (
|
||||
DELIVERY_OPTION_DEFAULTS, DELIVERY_SHARE_FRACTION, REASON_CODE,
|
||||
@@ -592,7 +592,21 @@ check("...and the SHARES now differ, which is OPT-09 and not a weakening of the
|
||||
"cards meet here from opposite sides: OPT-09 stops the ASK, this file "
|
||||
"grades the ALARM, and neither can do the other's half",
|
||||
_pw != _pf
|
||||
and _sf[-1]["shares"][1] == 0.0 and _sw[-1]["shares"][1] == 2000.0)
|
||||
and _sf[-1]["shares"][1] == 0.0
|
||||
and max(r["shares"][1] for r in _sw) == 2000.0)
|
||||
# SAFETY-73. A unit that gives < 100 W for 12 cycles while asked > 500 W is a
|
||||
# battery that refuses (owner, 2026-09-27): it is closed, its share moves, and
|
||||
# SAFETY-42 is left with units that deliver something but not enough. This
|
||||
# fixture compresses `delivery_hold_s` to 1 s at 0.2 s cycles, so the report
|
||||
# still comes first here. On a site 185 s against 60 s puts the refusal first.
|
||||
_ref_at = next((i for i, r in enumerate(_sw) if r["shares"][1] == 0.0), None)
|
||||
check("SAFETY-73: the wedged arm's B, giving 0 W against 2000 W, is refused "
|
||||
"after 12 cycles of that evidence and asked 0 W from then, the report "
|
||||
"having come first only because this fixture's hold is 1 s",
|
||||
_ref_at is not None and _ref_at >= control.SETTLE_CYCLES
|
||||
and all(r["shares"][1] > 0 for r in _sw[:_ref_at])
|
||||
and all(r["shares"][1] == 0.0 for r in _sw[_ref_at:])
|
||||
and _cw.inverters[1].refused == 1)
|
||||
check("...and the state of charge is still what tells them apart",
|
||||
[r["soc"] for r in _sw] != [r["soc"] for r in _sf])
|
||||
print(f" both arms, last cycle: grid {_sw[-1]['grid']:.0f} W, shares "
|
||||
@@ -640,10 +654,10 @@ check("...and `account()` STILL turns this pack away if the ask does arrive - "
|
||||
account(live=True, parked=False, soc=_cold_b.soc,
|
||||
bms_floor=_cold_b.bms_soc_floor) is not None)
|
||||
check("...and the WEDGED arm's B differs from it in exactly that one place - "
|
||||
"which is why it is still asked for its share, and still named",
|
||||
"which is why it was asked for its share until the refusal, and named",
|
||||
account(live=True, parked=False, soc=_cw.inverters[1].soc,
|
||||
bms_floor=_cw.inverters[1].bms_soc_floor) is None
|
||||
and float(_cw.inverters[1].standing_w()) > 0)
|
||||
and _sw[0]["shares"][1] > 0 and _sw[-1]["named"] == ("inverter-b",))
|
||||
|
||||
# ⚠️ WHICH FLOOR, AND THIS IS A WIRING CHECK THAT THE PURE ONES ABOVE CANNOT
|
||||
# MAKE. `peakguard.pack_floor_pct()` conjoins a pack's own cut-out with the
|
||||
@@ -916,9 +930,13 @@ check("...and EVERY WATT IS THE SAME. Grid, site target, both shares and both "
|
||||
"reported or not - which is what 'it does not act' means, stated as a "
|
||||
"measurement instead of as an intention",
|
||||
_power_domain(_sw) == _power_domain(_sn))
|
||||
check("...the wedged unit is still being commanded its share after the trip, "
|
||||
"not parked: this is NOT SAFETY-02's remedy and must not become it",
|
||||
abs(float(_cw.inverters[1].target)) > 0)
|
||||
_trip_at = next((i for i, r in enumerate(_sw) if r["named"]), None)
|
||||
check("...the wedged unit is still commanded its share after the trip, not "
|
||||
"parked by this guard: this is NOT SAFETY-02's remedy. What later takes "
|
||||
"the share is SAFETY-73's refusal, which runs the same in the arm where "
|
||||
"this guard never trips (the line above)",
|
||||
_trip_at is not None and _ref_at is not None and _trip_at < _ref_at
|
||||
and all(r["shares"][1] > 0 for r in _sw[_trip_at:_ref_at]))
|
||||
check("...and nothing named `delivery` reaches the arbiter - the resolution's "
|
||||
"own sentence is unchanged by the trip",
|
||||
"deliver" not in _cw.reason.lower() and _cw.reason == _cn.reason)
|
||||
|
||||
@@ -2655,7 +2655,7 @@ check("...and so does the persistent notification, which outlives the page and "
|
||||
# wants from you, not an edit.
|
||||
CLAIM_SOURCES = {"device", "supervised", "failsafe", "safety", "peak",
|
||||
"arbitrage", "maintenance", "loop", "circulation",
|
||||
"sign_site", "pack"}
|
||||
"sign_site", "pack", "refused"}
|
||||
# The two appends that file a claim BUILT ELSEWHERE in the method. Named here so
|
||||
# that a THIRD such indirection reads as an unrecognised append rather than as a
|
||||
# silent gap in the scan.
|
||||
@@ -2697,7 +2697,7 @@ check("every `claims.append(...)` in main.py's cycle is one this scan can READ "
|
||||
"- a claim filed through a shape it cannot parse has to fail here rather "
|
||||
"than be counted as nothing, which is how a scan like this goes quietly "
|
||||
"vacuous", len(_appends) >= 10 and None not in _filed)
|
||||
check("...and the sources that cycle can file are EXACTLY these ELEVEN. THIS "
|
||||
check("...and the sources that cycle can file are EXACTLY these TWELVE. THIS "
|
||||
"is what makes part 10 a tripwire: replay_loop() hand-builds the claim "
|
||||
"list, so it cannot see a claim main.py adds - and a loop-side SoC "
|
||||
"reserve is a new source. Filing one takes this line red on the line it "
|
||||
@@ -2848,7 +2848,8 @@ check("...and the split is the one ARB-03 argued, with SAFETY-31's and "
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE}
|
||||
== {"loop", "peak", "arbitrage", "safety", "circulation", "sign_site"}
|
||||
and {s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT}
|
||||
== {"device", "supervised", "failsafe", "maintenance", "pack"})
|
||||
== {"device", "supervised", "failsafe", "maintenance", "pack",
|
||||
"refused"})
|
||||
|
||||
# The shipped roster is ONE inverter, so §6.2's identity holds and every claim a
|
||||
# real cycle files is a site claim. Observed on the claims main.py's own resolve
|
||||
@@ -2945,7 +2946,7 @@ check("⚠️ AND THIS IS THE BREAKING HALF. Give the same Controller a second "
|
||||
"rest of the roster goes on pushing the same way - and this line goes red",
|
||||
_routed == {"device": "inverter-a", "supervised": "inverter-a",
|
||||
"failsafe": "inverter-a", "maintenance": "inverter-a",
|
||||
"pack": "inverter-a",
|
||||
"pack": "inverter-a", "refused": "inverter-a",
|
||||
"loop": ACTUATOR_SITE, "peak": ACTUATOR_SITE,
|
||||
"arbitrage": ACTUATOR_SITE, "safety": ACTUATOR_SITE,
|
||||
"circulation": ACTUATOR_SITE, "sign_site": ACTUATOR_SITE})
|
||||
@@ -3027,13 +3028,13 @@ _unit_sources_unrouted = [
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT and "," not in r[1]]
|
||||
print(f" {len(_direct)} direct appends, each read at its own line: "
|
||||
+ ", ".join(f"main.py:{ln} {s} -> {a}" for s, a, ln in _routing))
|
||||
check("all ELEVEN of `Controller.cycle()`'s DIRECT appends route through "
|
||||
check("all THIRTEEN of `Controller.cycle()`'s DIRECT appends route through "
|
||||
"`self.actuator_of(<string literal>)`, so this scan can read the routing "
|
||||
"of EVERY one of them. An append that computed its actuator, or omitted "
|
||||
"the argument, or hand-wrote a string, fails HERE rather than being "
|
||||
"silently skipped - which is how a scan like this goes quietly vacuous, "
|
||||
"and 10f is in this file because that already happened once",
|
||||
len(_direct) == 11
|
||||
len(_direct) == 13
|
||||
and all(a is not None and a.startswith("self.actuator_of('")
|
||||
for _s, a, _ln in _routing))
|
||||
check("⚠️ AND AT EVERY ONE OF THE ELEVEN THE LITERAL IT ROUTES THROUGH IS THE "
|
||||
@@ -3050,15 +3051,15 @@ check("⚠️ AND EVERY PER-INVERTER APPEND NAMES THE INVERTER IT IS ABOUT. "
|
||||
"site-scoped sources and is the whole defect for a per-inverter one: a "
|
||||
"`device` limit built inside the roster loop and routed without `inv` "
|
||||
"files inverter B's rating on inverter A, where it binds the wrong "
|
||||
"share. Six of the eleven appends are SCOPE_UNIT - `device`, "
|
||||
"`supervised`, `failsafe`, maintenance's two and OPT-09's `pack` - and "
|
||||
"all six pass one. "
|
||||
"share. Eight of the thirteen appends are SCOPE_UNIT - `device`, "
|
||||
"`supervised`, `failsafe`, maintenance's two, OPT-09's `pack` and "
|
||||
"SAFETY-73's two `refused` - and all eight pass one. "
|
||||
"SAFETY-30's `sign_site` is deliberately NOT one of them: it is filed on "
|
||||
"the site, beside `circulation`, because the number that tripped it is "
|
||||
"the site target",
|
||||
_unit_sources_unrouted == []
|
||||
and len([r for r in _routing
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT]) == 6)
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT]) == 8)
|
||||
check("...and the only appends this pin does NOT reach are the two that file a "
|
||||
"claim BUILT ELSEWHERE - `peak_claim` and `arb_claim` - which have no "
|
||||
"`actuator=` at the call site to mis-type. Their routing is pinned where "
|
||||
@@ -3067,7 +3068,7 @@ check("...and the only appends this pin does NOT reach are the two that file a "
|
||||
"arbitrage.claim() by test_arbitrage.py",
|
||||
sorted(_indirect) == sorted(CLAIM_BUILDERS)
|
||||
and len(_direct) + len(_indirect) == len(_appends))
|
||||
check("...and between them the twelve appends account for exactly the eleven "
|
||||
check("...and between them the fifteen appends account for exactly the twelve "
|
||||
"sources 10f pins, so the routing pin and the source set are one scan "
|
||||
"and neither can drift from the other",
|
||||
{s for s, _a, _ln in _routing} | set(CLAIM_BUILDERS.values())
|
||||
@@ -3119,7 +3120,7 @@ check("⚠️ AND THE RATING LIMITS ARE FILED ONCE PER INVERTER, ON ITS OWN "
|
||||
("supervised", "inverter-a"),
|
||||
("supervised", "inverter-b")])
|
||||
check("...and naming those three is not an accident of this fixture but the "
|
||||
"reason the static pin exists - SEVEN of the eleven sources need a state "
|
||||
"reason the static pin exists - EIGHT of the twelve sources need a state "
|
||||
"no check in this file reaches. SAFETY-31's `circulation` is one of the "
|
||||
"seven: it is filed only while the site is MEASURED to be circulating, "
|
||||
"which no fixture here is. SAFETY-30's `sign_site` is another, and it "
|
||||
@@ -3127,7 +3128,8 @@ check("...and naming those three is not an accident of this fixture but the "
|
||||
"standing opposed to the meter for its whole window",
|
||||
{c.source for c in _cl2}
|
||||
== CLAIM_SOURCES - {"failsafe", "safety", "maintenance", "peak",
|
||||
"arbitrage", "circulation", "sign_site"})
|
||||
"arbitrage", "circulation", "sign_site",
|
||||
"refused"})
|
||||
# ⚠️ AND NOW THE HALF THAT WAS EVIDENCE-SHAPED AND OBSERVED NOTHING. The three
|
||||
# checks above grade WHICH ACTUATOR each claim lands on. They say nothing about
|
||||
# WHOSE NUMBERS the bound is built from - and those are two different defects
|
||||
|
||||
@@ -0,0 +1,480 @@
|
||||
"""Runnable check for SAFETY-73. `python3 test_refusal_units.py`
|
||||
|
||||
SAFETY-52 per inverter. With two or more inverters, a battery that refuses
|
||||
(gives < 100 W for 12 cycles while asked > 500 W, or trips the stale-reading
|
||||
gate on a ~0 W reading) is closed in that direction by its own P_SAFETY limit,
|
||||
so the allocator hands its share to the others. It is probed at 200 W every
|
||||
15 minutes, one inverter at a time. When every inverter refuses the same way
|
||||
the site holds 0 W. When a refusal ends the site target restarts from the watts
|
||||
on the wire. DECISIONS/SAFETY-73 has the record.
|
||||
|
||||
Drives the REAL `Controller` (read_inputs + cycle, the real freshness gate,
|
||||
allocator, OPT-09 pack claim and SAFETY-42 detector) with two inverters in
|
||||
simulated time. At the cut-out a battery reads -4 W for any request >= -4 W
|
||||
and accepts charge. Two register shapes: FLAT at -4 W (the 09-06 capture) and
|
||||
JITTER +-3 W (the gate cannot arm). `OLD` runs the same fixture with the
|
||||
per-unit refusal switched off, which is 652097a's behaviour at N>1.
|
||||
|
||||
Mutations (MUTATION.md, `python3 -B`, copies purged of `__pycache__`), graded
|
||||
over this file / test_delivery / test_refusal. Every one is red here:
|
||||
|
||||
# mutation reds
|
||||
--- --------------------------------------------------------- -------
|
||||
U1 main.py: the per-unit engage clause never fires 7/2/0
|
||||
U2 main.py: the N>1 stale-reading seed returns at once 14/0/0
|
||||
U3 main.py: no `refused` claim is filed 13/2/0
|
||||
U4 main.py: a probe never pins (always the closed limit) 7/0/0
|
||||
U5 main.py: a probe pin stands whatever the site target 1/0/0
|
||||
U6 main.py: no reseed of the site target when a refusal ends 1/0/0
|
||||
U7 main.py: no site hold when every inverter refuses 2/0/0
|
||||
U8 main.py: the other-direction exit removed (charge counter) 1/0/0
|
||||
U9 main.py: the delivery exit removed 3/0/0
|
||||
U10 main.py: probes are no longer one at a time 1/0/0
|
||||
U11 main.py: the above-cut-out WARNING condition inverted 1/0/0
|
||||
U12 main.py: SAFETY-42's account no longer sees a small ask 1/0/0
|
||||
U13 main.py: a unit engages above `saturation_w`, not PROBE_W 1/0/0
|
||||
|
||||
On 652097a itself this file stops at the first sample (`Inverter` has no
|
||||
`refused`); its OLD arms reproduce that tree's N>1 behaviour instead, and
|
||||
every PRECONDITION line is graded against them.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import logging
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app import control
|
||||
from app.control import PROBE_EVERY_S, PROBE_S, PROBE_W
|
||||
from app.main import Controller
|
||||
from app.arbiter import P_LOOP, P_PEAK, P_SAFETY, Claim, resolve
|
||||
import app.main as m
|
||||
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
TICK = 5.0
|
||||
CUT_W = -4.0
|
||||
H = 3600.0
|
||||
BASE = datetime(2026, 9, 6, 19, 30, tzinfo=timezone.utc)
|
||||
UNITS = ("a", "b")
|
||||
|
||||
|
||||
class _Store:
|
||||
def __init__(self):
|
||||
from app.store import DEFAULTS
|
||||
self.data = dict(DEFAULTS)
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
class _Hass:
|
||||
"""A house, one meter, and two batteries that follow unless cut out."""
|
||||
|
||||
def __init__(self, load, cut, soc, jitter):
|
||||
self.load, self.cut, self.soc, self.jitter = load, cut, soc, jitter
|
||||
self.cmd = {u: 0.0 for u in UNITS}
|
||||
self.t = 0.0
|
||||
|
||||
def batt(self, u):
|
||||
c = self.cmd[u]
|
||||
if self.cut[u](self.t) and c >= CUT_W:
|
||||
if self.jitter:
|
||||
return CUT_W + ((int(self.t / TICK) % 3) - 1) * 3.0
|
||||
return CUT_W
|
||||
return float(round(c))
|
||||
|
||||
def grid(self):
|
||||
return self.load(self.t) - sum(self.batt(u) for u in UNITS)
|
||||
|
||||
async def limits(self, e):
|
||||
return (-2000.0, 2000.0, 1.0)
|
||||
|
||||
async def call(self, *a):
|
||||
return True
|
||||
|
||||
async def number(self, e, invert=False):
|
||||
if e == "sensor.grid":
|
||||
return self.grid()
|
||||
u = e[-1]
|
||||
if e.startswith("sensor.soc"):
|
||||
v = self.soc[u]
|
||||
return v(self.t) if callable(v) else v
|
||||
if e.startswith("sensor.batt"):
|
||||
return self.batt(u)
|
||||
return None
|
||||
|
||||
async def set_number(self, e, v):
|
||||
self.cmd[e[-1]] = float(v)
|
||||
return True
|
||||
|
||||
|
||||
def _off(c):
|
||||
"""652097a's N>1 behaviour: nothing refuses per unit."""
|
||||
c._unit_refusals = lambda: None
|
||||
c._unit_refusal_start = lambda *a, **k: None
|
||||
|
||||
|
||||
def run(load, cut, dur, *, soc=None, jitter=False, old=False, events=None,
|
||||
extra=None):
|
||||
"""Real cycles every TICK of simulated time. Rows are dicts per cycle."""
|
||||
async def go():
|
||||
hass = _Hass(load, cut, soc or {"a": 50.0, "b": 50.0}, jitter)
|
||||
inv = [{"name": f"inverter-{u}", "setpoint_entity": f"number.sp_{u}",
|
||||
"soc_entity": f"sensor.soc_{u}",
|
||||
"batt_entity": f"sensor.batt_{u}",
|
||||
"max_w": 2000, "bms_soc_floor": 10} for u in UNITS]
|
||||
o = {"meter_entity": "sensor.grid", "meter_source": "off",
|
||||
"inverters": inv, "gain": 0.6, "slew_w": 400,
|
||||
"target_grid_w": -10, "deadband_w": 15, "step_w": 10,
|
||||
"heartbeat_s": 10, "stale_input_s": 15, "auto_start": True}
|
||||
o.update(extra or {})
|
||||
c = Controller(o, hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
for i in c.inverters:
|
||||
i.dev_min, i.dev_max = -2000.0, 2000.0
|
||||
c.auto = True
|
||||
if old:
|
||||
_off(c)
|
||||
real_dt = m.datetime
|
||||
clock = [0.0]
|
||||
|
||||
class _DT(real_dt):
|
||||
@classmethod
|
||||
def now(cls, tz=None):
|
||||
return BASE + timedelta(seconds=clock[0])
|
||||
|
||||
m.datetime = _DT
|
||||
rows = []
|
||||
trips = {u: 0 for u in UNITS}
|
||||
was = {u: False for u in UNITS}
|
||||
pending = dict(events or {})
|
||||
try:
|
||||
t = 0.0
|
||||
while t < dur:
|
||||
hass.t = clock[0] = t
|
||||
for et in sorted(pending):
|
||||
if et <= t:
|
||||
pending.pop(et)(c)
|
||||
await c.read_inputs(now_mono=t)
|
||||
for u, i in zip(UNITS, c.inverters):
|
||||
s = i.batt_fresh.stale
|
||||
trips[u] += s and not was[u]
|
||||
was[u] = s
|
||||
await c.cycle()
|
||||
rows.append(dict(
|
||||
t=t, grid=hass.grid(), site=c.target, reason=c.loop_reason,
|
||||
a=hass.cmd["a"], b=hass.cmd["b"],
|
||||
ra=c.inverters[0].refused, rb=c.inverters[1].refused,
|
||||
da=c.inverters[0].delivery_wd.tripped,
|
||||
db=c.inverters[1].delivery_wd.tripped))
|
||||
t += TICK
|
||||
finally:
|
||||
m.datetime = real_dt
|
||||
return rows, trips, c
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
def after(rows, t0, t1=None):
|
||||
return [r for r in rows if r["t"] >= t0 and (t1 is None or r["t"] < t1)]
|
||||
|
||||
|
||||
def mean(rows, k):
|
||||
return sum(r[k] for r in rows) / len(rows) if rows else float("nan")
|
||||
|
||||
|
||||
def never(t):
|
||||
return False
|
||||
|
||||
|
||||
def cut_at(t0, t1=None):
|
||||
return lambda t: t >= t0 and (t1 is None or t < t1)
|
||||
|
||||
|
||||
def probes(rows, k):
|
||||
"""Start times of runs where refused unit `k` is asked exactly PROBE_W."""
|
||||
out, prev = [], False
|
||||
for r in rows:
|
||||
on = abs(r[k]) == PROBE_W and r["r" + k] != 0
|
||||
if on and not prev:
|
||||
out.append(r["t"])
|
||||
prev = on
|
||||
return out
|
||||
|
||||
|
||||
SHAPES = (("flat", False), ("jitter", True))
|
||||
|
||||
# ==============================================================================
|
||||
print("1. case a: house 3000 W, both give power, A cuts out at 120 s")
|
||||
# ==============================================================================
|
||||
for shape, jit in SHAPES:
|
||||
new, ntr, cn = run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, H,
|
||||
jitter=jit)
|
||||
old, otr, _ = run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, H,
|
||||
jitter=jit, old=True)
|
||||
tail_n, tail_o = after(new, 300), after(old, 300)
|
||||
held = [r for r in tail_n if abs(r["a"]) != PROBE_W]
|
||||
print(f" {shape}: old B {mean(tail_o, 'b'):.0f} W grid "
|
||||
f"{mean(tail_o, 'grid'):+.0f} W trips A {otr['a']}; new B "
|
||||
f"{mean(tail_n, 'b'):.0f} W grid {mean(tail_n, 'grid'):+.0f} W "
|
||||
f"trips A {ntr['a']}")
|
||||
check(f"{shape}: PRECONDITION: on the old law B never takes over (mean "
|
||||
f"under 1950 W) while A gives nothing",
|
||||
mean(tail_o, "b") < 1950 and mean(tail_o, "grid") > 1050)
|
||||
check(f"{shape}: A is refused and asked 0 W outside its probes, B carries "
|
||||
f"its rating, and the grid imports only what B cannot give",
|
||||
cn.inverters[0].refused == 1 and all(r["a"] == 0.0 for r in held)
|
||||
and min(r["b"] for r in tail_n) == 2000.0
|
||||
and abs(mean(tail_n, "grid") - 1004) < 20)
|
||||
check(f"{shape}: A's stale-reading gate trips at most once, the site is "
|
||||
f"never stopped after the first 5 minutes, and SAFETY-42 does not "
|
||||
f"report A as not delivering",
|
||||
ntr["a"] <= 1
|
||||
and all(r["reason"] != "not-running" for r in tail_n)
|
||||
and not any(r["da"] for r in new))
|
||||
|
||||
# ==============================================================================
|
||||
print("2. case b: house 1200 W, which B alone can carry, A cuts out")
|
||||
# ==============================================================================
|
||||
for shape, jit in SHAPES:
|
||||
new, ntr, cn = run(lambda t: 1200.0, {"a": cut_at(120), "b": never}, H,
|
||||
jitter=jit)
|
||||
old, _, _ = run(lambda t: 1200.0, {"a": cut_at(120), "b": never}, H,
|
||||
jitter=jit, old=True)
|
||||
tail_n, tail_o = after(new, 300), after(old, 300)
|
||||
imp = sum(max(0.0, r["grid"]) for r in tail_n) * TICK / H
|
||||
print(f" {shape}: old grid {mean(tail_o, 'grid'):+.0f} W, new grid "
|
||||
f"{mean(tail_n, 'grid'):+.0f} W, new import {imp:.0f} Wh")
|
||||
check(f"{shape}: PRECONDITION: the old law leaves a standing import",
|
||||
mean(tail_o, "grid") > 250)
|
||||
check(f"{shape}: B takes over the whole house and the grid sits near its "
|
||||
f"target", abs(mean(tail_n, "grid") + 10) < 25 and imp < 10)
|
||||
pa = probes(new, "a")
|
||||
in_probe = [r for r in new
|
||||
if any(p <= r["t"] < p + PROBE_S for p in pa)]
|
||||
check(f"{shape}: A is probed at 200 W every 15 minutes while B carries "
|
||||
f"the rest, and the two never pull opposite ways",
|
||||
len(pa) >= 3
|
||||
and all(abs(q - p - PROBE_EVERY_S - PROBE_S) <= 2 * TICK
|
||||
for p, q in zip(pa, pa[1:]))
|
||||
and all(r["b"] > 0 for r in in_probe)
|
||||
and all(r["a"] * r["b"] >= 0 for r in new))
|
||||
|
||||
# ==============================================================================
|
||||
print("3. case c: both cut out; the site holds 0 W, probes one at a time")
|
||||
# ==============================================================================
|
||||
for shape, jit in SHAPES:
|
||||
new, ntr, cn = run(lambda t: 3000.0, {"a": cut_at(120), "b": cut_at(150)},
|
||||
1.5 * H, jitter=jit)
|
||||
old, _, _ = run(lambda t: 3000.0, {"a": cut_at(120), "b": cut_at(150)},
|
||||
1.5 * H, jitter=jit, old=True)
|
||||
tail_n, tail_o = after(new, 600), after(old, 600)
|
||||
pa, pb = probes(new, "a"), probes(new, "b")
|
||||
print(f" {shape}: old mean asks A/B {mean(tail_o, 'a'):.0f}/"
|
||||
f"{mean(tail_o, 'b'):.0f} W; new {mean(tail_n, 'a'):.0f}/"
|
||||
f"{mean(tail_n, 'b'):.0f} W, probes A {len(pa)} B {len(pb)}")
|
||||
check(f"{shape}: PRECONDITION: the old law keeps asking two empty "
|
||||
f"batteries", mean(tail_o, "a") > 150 and mean(tail_o, "b") > 150)
|
||||
check(f"{shape}: the site holds 0 W: the loop says `battery refuses` or "
|
||||
f"`battery probe` and each battery is asked 0 W or its probe",
|
||||
all(r["reason"] in (control.REFUSED, control.PROBING)
|
||||
for r in tail_n)
|
||||
and all(r["a"] in (0.0, PROBE_W) and r["b"] in (0.0, PROBE_W)
|
||||
for r in tail_n))
|
||||
check(f"{shape}: both batteries are probed, never at the same time",
|
||||
len(pa) >= 3 and len(pb) >= 3
|
||||
and not any(r["a"] and r["b"] for r in new if r["t"] > 300))
|
||||
|
||||
# ==============================================================================
|
||||
print("4. recovery: the reseed stops the parked site target reaching the grid")
|
||||
# ==============================================================================
|
||||
# Both cut, the house drops to 940 W at 1 h, A recovers at 1.5 h with no sign
|
||||
# change. Phase A, with the envelope but no reseed and no site hold: -1059 W.
|
||||
ld = (lambda t: 3000.0 if t < H else 940.0)
|
||||
for shape, jit in SHAPES:
|
||||
rows, _, c = run(ld, {"a": cut_at(120, 1.5 * H), "b": cut_at(150)},
|
||||
2 * H, jitter=jit)
|
||||
win = after(rows, 1.5 * H, 1.5 * H + 900)
|
||||
worst = min(r["grid"] for r in win)
|
||||
print(f" {shape}: worst grid after A recovers {worst:+.0f} W; A "
|
||||
f"refused {c.inverters[0].refused}")
|
||||
check(f"{shape}: A's recovery is found (at its next probe at the latest) "
|
||||
f"and never exports more than 250 W",
|
||||
c.inverters[0].refused == 0 and worst > -250
|
||||
and any("BATTERY REFUSES ENDED inverter-a" in e for e in c.events))
|
||||
|
||||
# Case a: B at its rating, the site target parked at 3600 W while the house
|
||||
# still imports; the house falls to 2500 W and A recovers. Without the reseed A
|
||||
# is handed the parked 1600 W at once, 1100 W more than the house needs.
|
||||
ld2 = (lambda t: 3000.0 if t < 0.5 * H else 2500.0)
|
||||
rows, _, c = run(ld2, {"a": cut_at(120, 0.75 * H), "b": never}, 1.5 * H)
|
||||
win = after(rows, 0.75 * H, 0.75 * H + 900)
|
||||
print(f" a: worst grid when A recovers {min(r['grid'] for r in win):+.0f} W")
|
||||
check("case a: a recovery hands A no parked site target (worst export under "
|
||||
"250 W)", min(r["grid"] for r in win) > -250
|
||||
and any("BATTERY REFUSES ENDED inverter-a" in e for e in c.events))
|
||||
|
||||
# ==============================================================================
|
||||
print("5. exits, words and the circulation guard")
|
||||
# ==============================================================================
|
||||
# Solar: the house exports from 30 min, so the loop wants to charge.
|
||||
rows, _, c = run(lambda t: 3000.0 if t < 0.5 * H else -2500.0,
|
||||
{"a": cut_at(120), "b": never}, H)
|
||||
check("the grid asking the other direction lets A charge at once (its limit "
|
||||
"closes only the refused direction) and a minute of charge ends the "
|
||||
"refusal",
|
||||
c.inverters[0].refused == 0 and min(r["a"] for r in after(rows, 0.6 * H))
|
||||
< -500 and any("the other way" in e for e in c.events))
|
||||
|
||||
|
||||
def _stop(c):
|
||||
c.auto = False
|
||||
|
||||
|
||||
rows, _, c = run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, 0.5 * H,
|
||||
events={1200.0: _stop})
|
||||
check("stopping control ends the refusal",
|
||||
c.inverters[0].refused == 0
|
||||
and any("control stopped" in e for e in c.events))
|
||||
|
||||
# A small house: the site asks under 200 W, so a probe may not pin A (B would
|
||||
# have to charge while A gives power). The probe waits instead.
|
||||
rows, _, c = run(lambda t: 3000.0 if t < 600 else 120.0,
|
||||
{"a": cut_at(120), "b": never}, 1.2 * H)
|
||||
check("with the site asking under 200 W no probe is sent and no inverter is "
|
||||
"ever asked the opposite way to the other",
|
||||
c.inverters[0].refused == 1
|
||||
and probes(after(rows, 700), "a") == []
|
||||
and all(r["a"] * r["b"] >= 0 for r in rows)
|
||||
and not any("ARBITER" in e for e in c.events))
|
||||
|
||||
# The hold binds every strategy's ask: a peak-guard SET at P_PEAK on the site
|
||||
# is still placed around a refusing unit's closed limit.
|
||||
_res = resolve([Claim.set("peak", P_PEAK, 3000.0, "quarter peak"),
|
||||
Claim.set("loop", P_LOOP, 500.0, "tracking"),
|
||||
Claim.limit("supervised", P_SAFETY, -2000.0, 2000.0,
|
||||
actuator="inverter-a"),
|
||||
Claim.limit("supervised", P_SAFETY, -2000.0, 2000.0,
|
||||
actuator="inverter-b"),
|
||||
Claim.limit("refused", P_SAFETY, hi=0.0,
|
||||
reason=control.REFUSED, actuator="inverter-a")],
|
||||
units=("inverter-a", "inverter-b"),
|
||||
live=("inverter-a", "inverter-b"))
|
||||
check("a P_SAFETY refusal limit binds a higher-priority strategy too: the "
|
||||
"peak guard's 3000 W goes to B, A gets 0 W",
|
||||
_res.shares.get("inverter-a") == 0 and _res.shares.get("inverter-b")
|
||||
== 2000)
|
||||
|
||||
|
||||
class _Grab(logging.Handler):
|
||||
def __init__(self):
|
||||
super().__init__()
|
||||
self.lines = []
|
||||
|
||||
def emit(self, record):
|
||||
self.lines.append((record.levelno, record.getMessage()))
|
||||
|
||||
|
||||
_g = _Grab()
|
||||
_lg = logging.getLogger("goodwe")
|
||||
_lv = _lg.level
|
||||
_lg.setLevel(logging.INFO)
|
||||
_lg.addHandler(_g)
|
||||
run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, 600)
|
||||
run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, 600,
|
||||
soc={"a": 10.0, "b": 50.0})
|
||||
_lg.removeHandler(_g)
|
||||
_lg.setLevel(_lv)
|
||||
warns = [x for lv, x in _g.lines if lv == logging.WARNING
|
||||
and "REFUSES_ABOVE_CUT_OUT" in x]
|
||||
infos = [x for lv, x in _g.lines if lv == logging.INFO
|
||||
and "BATTERY_REFUSES" in x]
|
||||
print(f" {warns} / {infos}")
|
||||
check("a refusal above the configured cut-out level logs INFO and one WARNING "
|
||||
"naming the inverter, and a battery at its cut-out logs neither "
|
||||
"(OPT-09's limit closes it first)",
|
||||
len(warns) == 1 and warns[0].startswith("inverter-a ")
|
||||
and len(infos) == 1 and infos[0].startswith("inverter-a:")
|
||||
and len(warns[0].split()) <= 25)
|
||||
|
||||
# A night load of 400 W: each unit is asked about 400 W once the loop has
|
||||
# made up A's missing half, under `saturation_w`. Engaging at PROBE_W is what
|
||||
# refuses A here; at 500 W it would keep a phantom share that SAFETY-43 names.
|
||||
rows, _, c = run(lambda t: 400.0, {"a": cut_at(0), "b": never}, 1200)
|
||||
check("a 400 W night load: A is refused at a share under 500 W, B carries the "
|
||||
"house and nothing reports A as not delivering",
|
||||
c.inverters[0].refused == 1 and not any(r["da"] for r in rows)
|
||||
and abs(mean(after(rows, 300), "grid") + 10) < 25
|
||||
and mean(after(rows, 300), "b") > 380)
|
||||
|
||||
# A night load of 150 W: A's share never passes PROBE_W, so it is never
|
||||
# refused, and SAFETY-43 must not name it as not delivering either: a battery
|
||||
# asked under 200 W that gives under 100 W is a refusal too small to call.
|
||||
rows, _, c = run(lambda t: 150.0, {"a": cut_at(0), "b": never}, 1200)
|
||||
check("a small share on an empty battery is neither refused nor reported as "
|
||||
"not delivering, and the grid stays near its target",
|
||||
c.inverters[0].refused == 0 and not any(r["da"] for r in rows)
|
||||
and abs(mean(after(rows, 300), "grid") + 10) < 25)
|
||||
|
||||
rows, _, c = run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, 600)
|
||||
notes = c.liveness_notes()
|
||||
check("the status page names the refusing inverter",
|
||||
any(n.startswith("inverter-a: the battery refuses to give power")
|
||||
for n in notes))
|
||||
|
||||
# Shadow mode writes nothing, so nothing is asked and nothing can refuse.
|
||||
rows, _, c = run(lambda t: 3000.0, {"a": cut_at(120), "b": never}, 1200,
|
||||
extra={"shadow_mode": True})
|
||||
check("shadow mode: no inverter is refused and both stay at 0 W",
|
||||
c.inverters[0].refused == 0 and c.inverters[1].refused == 0
|
||||
and all(r["a"] == 0.0 and r["b"] == 0.0 for r in rows))
|
||||
|
||||
# ==============================================================================
|
||||
print("6. one inverter is untouched")
|
||||
# ==============================================================================
|
||||
|
||||
|
||||
def _boom(*a, **k):
|
||||
raise AssertionError("SAFETY-73 code ran at N=1")
|
||||
|
||||
|
||||
_saved = {k: getattr(Controller, k) for k in (
|
||||
"_unit_refusals", "_unit_refusal_start", "_unit_refusal_end",
|
||||
"_unit_probe", "_site_refused")}
|
||||
for k in _saved:
|
||||
setattr(Controller, k, _boom)
|
||||
try:
|
||||
import test_refusal as _t1
|
||||
_one_ok = not _t1.fails
|
||||
except (AssertionError, SystemExit) as e:
|
||||
_one_ok = isinstance(e, SystemExit) and not e.code
|
||||
finally:
|
||||
for k, v in _saved.items():
|
||||
setattr(Controller, k, v)
|
||||
check("SAFETY-52's whole single-inverter suite passes with every SAFETY-73 "
|
||||
"method made to raise, so none of it runs at N=1", _one_ok)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||