Merge pull request 'SAFETY-90: the peak guard goes on after a P1 meter gap' (#175) from safety-90-peak-guard-gap into release/1.0
infra-pin / fresh (push) Successful in 2s
infra-pin / fresh (push) Successful in 2s
SAFETY-90: the peak guard goes on after a P1 meter gap (#175)
This commit was merged in pull request #175.
This commit is contained in:
@@ -0,0 +1,81 @@
|
||||
# SAFETY-90 - the peak guard goes on after a P1 meter gap
|
||||
|
||||
**Status: DEV 2026-10-05, for review.** Tests: `test_safety90.py`.
|
||||
|
||||
**The defect.** A meter gap longer than `meter_max_age_s` leaves seconds the
|
||||
quarter average does not count (`p1.QuarterAverager`, on purpose: a guess must
|
||||
not reach the bill record). `peakguard.blindness()` then called the projection
|
||||
blind for the rest of the quarter, so the floor was 0 W. During a HOLD the
|
||||
battery gave nothing and the quarter went over: SAFETY-86 rig case 7b, N=2,
|
||||
3964.8 W against a 3450 W aim, the month peak raised; N=1, 3701 W (review).
|
||||
The page still read "Keeping the grid near zero". At start-up mid-quarter the
|
||||
same rule left the start-up quarter blind, and a held battery was drawn as last
|
||||
resort (SAFETY-91 test, O2).
|
||||
|
||||
**The fix** (`peakguard.fill_gaps()`, `peakguard.gap_w()`,
|
||||
`Controller._fill_peak_gaps()`).
|
||||
- Once readings are back, every second of a silence longer than
|
||||
`meter_max_age_s` counts at `gap_w = max(the limit, the import just before
|
||||
the gap, the import just after it)`, where "import" is the grid plus the
|
||||
batteries' discharge, i.e. with the batteries at 0 W. The gap's first
|
||||
`meter_max_age_s`, which the averager credits at the last reading, is topped
|
||||
up to `gap_w` too. The guard then grades the quarter as usual, so it is not
|
||||
blind and gives what keeps the quarter at the aim.
|
||||
- **The bound.** The count is at or above the true import as long as, during
|
||||
the gap, the house load (less solar) stayed at or under the higher of the loads seen just
|
||||
before and just after it, or under the limit, and the batteries did not
|
||||
start charging (during a gap they hold their last command, then go to 0 W).
|
||||
It never counts the gap below the limit. A load that rises above all three
|
||||
only inside the gap is the one case it can miss.
|
||||
- **Cost of the bound.** It is conservative: with the house at 6500 W, a 30 s
|
||||
to 5 min gap lands the quarter 100-180 W under the aim (table below), paid in
|
||||
battery energy.
|
||||
- **While the gap lasts** nothing changes: the reading is too old to steer by,
|
||||
the guard is blind (floor 0 W) and the "inputs missing" stop sets 0 W, as
|
||||
before.
|
||||
- **Before the first reading** (start-up or restart mid-quarter) the
|
||||
add-on was down, so the batteries were at 0 W (it sets 0 W when it stops,
|
||||
the ESP32 watchdog after 30 s). Those seconds count like a gap, at
|
||||
`gap_w(the limit, the import seen first)`; after a restart the restored
|
||||
reading's held `meter_max_age_s` is topped up the same way. The bound is
|
||||
the gap's, with only the "after" side known. A load the batteries cannot
|
||||
make up then raises "Load too high", which is true: that quarter is going
|
||||
over. The page says so: the status row "Peak guard: part of this
|
||||
15-minute period was not measured, counted as high use" and the home line
|
||||
"Part of this 15-minute period was not measured." / "Een deel van dit
|
||||
kwartier is niet gemeten." until the quarter ends.
|
||||
*Review:* the first version counted them at the aim, with "nothing is
|
||||
known" as the reason. The first reading does show the load, and with the
|
||||
batteries at 0 W the import was that load, not the aim: a 60 s restart
|
||||
during a 6500 W HOLD landed 3653 W against 3450 W.
|
||||
- The bill record (`quarter_blocks`) is unchanged: it still banks only what
|
||||
was measured. The estimate steers the guard and is never banked.
|
||||
- The action log gets one `PEAK_GUARD_GAP` row per gap, with the seconds and
|
||||
the watts it was counted at.
|
||||
- No option. The threshold is `meter_max_age_s`, the limit and the aim are
|
||||
`peak_cap_w` and `peak_margin_w`.
|
||||
|
||||
**Before -> after** (`test_safety90.py`, quarter as the meter really averages
|
||||
it, gap starting 300 s in; 10 s battery lag; aim 3450 W):
|
||||
|
||||
| case | before | after |
|
||||
|---|---|---|
|
||||
| N=1 HOLD 6500 W, gap 30 s / 60 s | 3456.6 / 5329.2 | 3346.2 / 3272.2 |
|
||||
| N=1 HOLD 5500 W, gap 5 min | 4717.9 | 3330.6 |
|
||||
| N=2 HOLD, B able, 6500 W, gap 30 s / 60 s | 3456.6 / 3865.6 | 3346.3 / 3272.7 |
|
||||
| N=2 HOLD, B able, 5500 W, gap 5 min | 3745.4 | 3288.9 |
|
||||
| N=2 HOLD, B held, 5500 W, gap 60 s | 3254.9, B drawn 2500 W | 3335.4, B 0 W |
|
||||
| gap across the edge, next quarter, N=1 / N=2 | 4100.0 / 3621.2 | 3446.3 / 3382.2 |
|
||||
| house 3000 -> 6500 W inside a 60 s gap, N=1 | 5255.6 | 3368.3 |
|
||||
| house 6500 -> 2000 W late in a 5 min gap, N=1 | 3629.2 | 3145.1 |
|
||||
| start-up 450 s in, N=1, house 5000 W (batteries at 0 W before it) | 5000.0 | 3450.0 |
|
||||
| restart, down 60 s / 150 s, N=1, house 6500 W | 4039.1 / 5483.3 | 3450.0 / 3450.0 |
|
||||
| meter never drops, N=1 and N=2 | | rows identical |
|
||||
|
||||
**Not changed.** The late-reading edge (SAFETY-91 test, O1): a reading late by
|
||||
less than `meter_max_age_s` is not a gap, and the seconds since it are not
|
||||
counted in the projection (on any quarter, not only after a gap). Near a
|
||||
quarter's end the 900/remaining gain turns that into a large negative excess
|
||||
and the floor drops for a cycle or more. Counting those seconds at the held
|
||||
reading would fix it, but it changes every quarter's last seconds on a
|
||||
healthy meter; it is handed back as its own card.
|
||||
@@ -1752,10 +1752,17 @@ ceiling at the cap, so a broken instrument makes the guard stricter, never loose
|
||||
**When it cannot see, it forbids importing.** Three states are not evidence and
|
||||
are checked before the projection is graded: no open quarter (a fresh averager
|
||||
projects a confident 0 W, which is under every ceiling there is), a meter gap
|
||||
longer than `meter_max_age_s`, and SAFETY-18's frozen-meter conjunction. In all
|
||||
three the claim becomes a floor of **0 W**. That is the backstop for the frozen
|
||||
meter: the alarm arrives at `meter_freeze_s` (300 s) of a 900 s billing quarter
|
||||
and commands nothing, and this stops the import.
|
||||
longer than `meter_max_age_s` while it lasts, and SAFETY-18's frozen-meter
|
||||
conjunction. In all three the claim becomes a floor of **0 W**. That is the
|
||||
backstop for the frozen meter: the alarm arrives at `meter_freeze_s` (300 s) of
|
||||
a 900 s billing quarter and commands nothing, and this stops the import.
|
||||
|
||||
**After a gap it goes on (SAFETY-90).** The seconds the meter missed count at
|
||||
the higher of the peak limit and the import seen just before and just after
|
||||
the gap, with the batteries at 0 W. Seconds before the add-on's first reading
|
||||
count the same way, at the import seen first, and the page says part of the
|
||||
period was not measured. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md has the
|
||||
bound.
|
||||
|
||||
**It trips, where the freeze detector only notifies,** and the captures are why.
|
||||
On the healthy reference day (2026-08-23) it engages on **zero** of 95 quarters.
|
||||
|
||||
@@ -904,7 +904,9 @@ def month_peak(c, now):
|
||||
if pg is not None:
|
||||
out["period_w"] = pg.projected_w
|
||||
ceiling = pg.ceiling_w or limit_w
|
||||
out["line"] = line_period(out["period_w"], ceiling, c.shadow)
|
||||
out["line"] = line_period(out["period_w"], ceiling, c.shadow,
|
||||
unmeasured=getattr(c, "peak_unmeasured_s", 0.0)
|
||||
> 0.0)
|
||||
return out
|
||||
|
||||
|
||||
@@ -1294,8 +1296,11 @@ def line_peak_not_covered() -> str:
|
||||
return _t("peak_not_covered")
|
||||
|
||||
|
||||
def line_period(period_w, limit_w, shadow) -> str:
|
||||
def line_period(period_w, limit_w, shadow, unmeasured=False) -> str:
|
||||
step = _w(shadow, "step_in", kw=_kw(limit_w))
|
||||
if unmeasured:
|
||||
# SAFETY-90: the add-on started during this period.
|
||||
return _t("period_unmeasured") + " " + step
|
||||
if period_w is None:
|
||||
return step
|
||||
return _t("period", kw=_kw(period_w)) + " " + step
|
||||
@@ -1369,6 +1374,7 @@ def _samples() -> list:
|
||||
("plan", line_peak_limit(3500, sh)),
|
||||
("plan", line_period(1240, 3500, sh)),
|
||||
("plan", line_period(None, 3500, sh)),
|
||||
("plan", line_period(1240, 3500, sh, unmeasured=True)),
|
||||
("plan", control_text(True, sh)),
|
||||
("plan", control_text(False, sh))]
|
||||
out += [("plan", run_grid_why(0.1412)), ("plan", run_grid_amount(1.23)),
|
||||
|
||||
@@ -947,6 +947,22 @@ class Controller:
|
||||
# SAFETY-81: what the alarm is graded on, beside the guard's decision.
|
||||
self._peak_proj = None
|
||||
self._peak_batt_prev = None
|
||||
# SAFETY-90: what a meter gap is counted at (`_fill_peak_gaps()`).
|
||||
self._gap_seen_w = None
|
||||
self._gap_w = None
|
||||
self._gap_block = None
|
||||
self._gap_filled_s = 0.0
|
||||
self._gap_held_ws = 0.0
|
||||
self._gap_pre = None
|
||||
self._unseen = None
|
||||
# A held sample TARIFF-01 restored from before this restart: the
|
||||
# averager credits it max_hold_s into the restart, at 0 W batteries.
|
||||
_held = self.p1.averager.held_since
|
||||
self._run_pre = (None if _held is None
|
||||
else (_held, self.p1.averager.held_net_w))
|
||||
self._unseen_held_ws = 0.0
|
||||
self.peak_gap_s = 0.0
|
||||
self.peak_unmeasured_s = 0.0
|
||||
self._peak_alarm_block = None
|
||||
self._peak_high_since = None
|
||||
self._peak_floor_limited = False
|
||||
@@ -2693,6 +2709,74 @@ class Controller:
|
||||
lo=p, reason=c.reason,
|
||||
actuator=u)
|
||||
|
||||
def _fill_peak_gaps(self, proj, now, reading):
|
||||
"""SAFETY-90: `proj` with a meter gap's uncounted seconds counted at
|
||||
`peakguard.gap_w()` of the imports seen just before and just after it,
|
||||
and those before this run's first reading likewise at the import seen
|
||||
first (shown as not measured).
|
||||
DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
|
||||
self.peak_gap_s = self.peak_unmeasured_s = 0.0
|
||||
avg = self.p1.averager
|
||||
since = avg.held_since
|
||||
if proj is None or proj.block_start is None or since is None:
|
||||
return proj
|
||||
if self._unseen is None and self.p1.last is not None:
|
||||
self._unseen = [proj.block_start, max(0.0, (
|
||||
since - proj.block_start).total_seconds() - avg.elapsed_s),
|
||||
since, None]
|
||||
seen = (None if self.grid is None or self.site_batt_w is None
|
||||
else float(self.grid) + max(0.0, float(self.site_batt_w)))
|
||||
if proj.block_start != self._gap_block:
|
||||
self._gap_block, self._gap_w = proj.block_start, None
|
||||
self._gap_filled_s = self._gap_held_ws = 0.0
|
||||
cap = float(self.o.get("peak_cap_w", 3500))
|
||||
ceiling = peakguard.quarter_ceiling_w(cap, reading)[0]
|
||||
unseen_on = (self._unseen is not None
|
||||
and self._unseen[0] == proj.block_start)
|
||||
if unseen_on and self._unseen[3] is None and seen is not None:
|
||||
# While the add-on was down the batteries were at 0 W, so the
|
||||
# seconds before its first reading count like a gap, at the
|
||||
# import seen first; a restored reading's held part is topped up.
|
||||
self._unseen[3] = peakguard.gap_w(ceiling, seen)
|
||||
if self._run_pre is not None:
|
||||
s0, g0 = self._run_pre
|
||||
h = (min(s0 + timedelta(seconds=avg.max_hold_s),
|
||||
self._unseen[2])
|
||||
- max(s0, proj.block_start)).total_seconds()
|
||||
self._unseen_held_ws = max(0.0, h) * max(
|
||||
0.0, self._unseen[3] - max(0.0, g0))
|
||||
kw = dict(tail_s=(now - since).total_seconds(),
|
||||
max_hold_s=avg.max_hold_s,
|
||||
unseen_s=self._unseen[1] if unseen_on else 0.0,
|
||||
unseen_w=(self._unseen[3] if unseen_on
|
||||
and self._unseen[3] is not None else ceiling))
|
||||
_p, gap_s, _u = peakguard.fill_gaps(proj, gap_w=0.0, **kw)
|
||||
if gap_s > self._gap_filled_s + peakguard.GAP_TOL_S:
|
||||
self._gap_w = peakguard.gap_w(ceiling, self._gap_w,
|
||||
self._gap_seen_w, seen)
|
||||
if self._gap_pre is not None:
|
||||
# The averager credited the gap's first max_hold_s at the
|
||||
# reading before it; top that part up to gap_w as well.
|
||||
s0, g0 = self._gap_pre
|
||||
h = (min(s0 + timedelta(seconds=avg.max_hold_s), since)
|
||||
- max(s0, proj.block_start)).total_seconds()
|
||||
self._gap_held_ws += max(0.0, h) * max(
|
||||
0.0, self._gap_w - max(0.0, g0))
|
||||
self.log_event(f"PEAK_GUARD_GAP: the meter missed {gap_s:.0f} s "
|
||||
f"of this 15-minute period, counted at "
|
||||
f"{self._gap_w:.0f} W",
|
||||
hint=messages.hint("peak_gap"))
|
||||
self._gap_filled_s = max(self._gap_filled_s, gap_s)
|
||||
if seen is not None:
|
||||
self._gap_seen_w = seen
|
||||
if self.grid is not None:
|
||||
self._gap_pre = (since, float(self.grid))
|
||||
out, self.peak_gap_s, self.peak_unmeasured_s = peakguard.fill_gaps(
|
||||
proj, gap_w=self._gap_w if self._gap_w is not None else ceiling,
|
||||
held_ws=self._gap_held_ws + (self._unseen_held_ws if unseen_on
|
||||
else 0.0), **kw)
|
||||
return out
|
||||
|
||||
def _peak_over_drain(self, claims, maint_results) -> None:
|
||||
"""SAFETY-83: at N=1 a peak floor above the drain rate outranks it.
|
||||
|
||||
@@ -4218,6 +4302,10 @@ class Controller:
|
||||
# gives for SAFETY-18 on a transport that cannot see `unchanged_s`.
|
||||
self._peak_proj = (None if not self.p1_enabled
|
||||
else self.peak.project(self.p1.averager, now))
|
||||
_reading = self.peak.peak(now) if self.p1_enabled else None
|
||||
# SAFETY-90: seconds a meter gap left uncounted are counted, so the
|
||||
# guard goes on after the readings return.
|
||||
self._peak_proj = self._fill_peak_gaps(self._peak_proj, now, _reading)
|
||||
# SAFETY-91: at N>=2 the quarter's edge is graded on the next quarter,
|
||||
# so a HOLD's ceiling does not lapse for a cycle onto a held battery.
|
||||
if self._peak_proj is not None and len(self.inverters) > 1:
|
||||
@@ -4232,7 +4320,7 @@ class Controller:
|
||||
batt_w=self.site_batt_w,
|
||||
cap_w=float(self.o.get("peak_cap_w", 3500)),
|
||||
margin_w=self.peak_margin_w,
|
||||
reading=self.peak.peak(now),
|
||||
reading=_reading,
|
||||
# ⚠️ SUMMED FROM THE PER-UNIT CONJUNCTION, WHICH IS AC 4. Each
|
||||
# unit contributes `min(its max_w, |its own device bounds|)`, so
|
||||
# inverter B's rating bounds inverter B. Conjoining the SUMS instead
|
||||
@@ -6390,6 +6478,11 @@ class Controller:
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_blind(
|
||||
peakguard.blind_kind(_pg.blind))})
|
||||
elif self.peak_unmeasured_s > 0.0:
|
||||
# SAFETY-90: the start of this quarter came before the first
|
||||
# reading, and the guard counts it as high use.
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_unmeasured()})
|
||||
elif _pg.engaged:
|
||||
out.append({"ok": False, "warn": True, "id": "peak_guard",
|
||||
"text": messages.row_peak_guard_on(
|
||||
|
||||
@@ -793,6 +793,12 @@ def row_peak_guard_blind(why: str) -> str:
|
||||
f"meanwhile")
|
||||
|
||||
|
||||
def row_peak_guard_unmeasured() -> str:
|
||||
"""SAFETY-90. Before the first reading; that part counts as high use."""
|
||||
return ("Peak guard: part of this 15-minute period was not measured, "
|
||||
"counted as high use")
|
||||
|
||||
|
||||
def row_peak_guard_on(floor_w, limit_w, *, shadow: bool = False) -> str:
|
||||
if shadow:
|
||||
return (f"Peak guard: would ask for {watts(floor_w)} to stay under "
|
||||
@@ -912,6 +918,7 @@ HINTS = {
|
||||
"peak_on": "Peak guard started",
|
||||
"peak_off": "Peak guard idle",
|
||||
"peak_blind": "Peak guard cannot read the meter well",
|
||||
"peak_gap": "Meter is back, the peak guard counts the missed time as high use",
|
||||
"peak_saturated": T_PEAK_SATURATED,
|
||||
"peak_reserve": T_PEAK_RESERVE,
|
||||
"meter_frozen": T_METER_FROZEN,
|
||||
@@ -1097,6 +1104,7 @@ def status_samples() -> list:
|
||||
("row_peak_guard_idle", GREEN, row_peak_guard_idle(1300, 2500, True)),
|
||||
("row_peak_guard_idle", GREEN, row_peak_guard_idle(1300, 2500, False)),
|
||||
("row_peak_guard_quiet", GREEN, row_peak_guard_quiet()),
|
||||
("row_peak_guard_unmeasured", AMBER, row_peak_guard_unmeasured()),
|
||||
*(("row_peak_guard_blind", AMBER, row_peak_guard_blind(k))
|
||||
for k in BLIND_WORDS),
|
||||
("row_peak_guard_on", AMBER, row_peak_guard_on(1200, 2500)),
|
||||
|
||||
@@ -312,6 +312,13 @@ class QuarterAverager:
|
||||
"""
|
||||
return self._last_net
|
||||
|
||||
@property
|
||||
def held_since(self) -> datetime | None:
|
||||
"""SAFETY-90: when the held sample arrived (its `ingest_ts`), or None."""
|
||||
if self._last_t is None:
|
||||
return None
|
||||
return datetime.fromtimestamp(self._last_t, timezone.utc)
|
||||
|
||||
@property
|
||||
def offtake_avg_w(self) -> float:
|
||||
"""Average offtake over the part of the open block seen so far."""
|
||||
|
||||
@@ -183,6 +183,8 @@ guard passes its own tests while being switched off:
|
||||
record). Those seconds make the projection read LOW, which is the
|
||||
under-guarding direction. The threshold is `max_hold_s` itself - the point
|
||||
p1.py already stops trusting a held sample - not a new number.
|
||||
SAFETY-90: once readings are back, main.py counts those seconds
|
||||
(`fill_gaps()`), so this holds only while the gap lasts.
|
||||
|
||||
* FROZEN. SAFETY-18's conjunction, evaluated through `freeze.looks_frozen()`
|
||||
rather than re-written here. A frozen meter is the worst case of all: the
|
||||
@@ -599,6 +601,57 @@ def blindness(projection, max_hold_s, frozen: bool) -> str | None:
|
||||
return None
|
||||
|
||||
|
||||
# SAFETY-90. Seconds of uncounted time below which nothing is filled: float
|
||||
# noise between the averager's sums and the wall clock, never a real gap.
|
||||
GAP_TOL_S = 1e-3
|
||||
|
||||
|
||||
def gap_w(ceiling_w, *seen_w) -> float:
|
||||
"""SAFETY-90: the watts a meter gap is counted at. The highest of the
|
||||
limit and `seen_w`, the import with the batteries at 0 W (grid + their
|
||||
discharge) just before and just after the gap; None entries are skipped.
|
||||
DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
|
||||
return max([float(ceiling_w)] + [float(w) for w in seen_w if w is not None])
|
||||
|
||||
|
||||
def fill_gaps(projection, *, tail_s, max_hold_s, unseen_s, gap_w, unseen_w,
|
||||
held_ws=0.0):
|
||||
"""SAFETY-90: `projection` with the seconds the averager did not count
|
||||
(a meter gap past `max_hold_s`) counted at `gap_w`, and those from before
|
||||
this run's first reading (`unseen_s`) at `unseen_w`. `held_ws` is added
|
||||
too: what the gap's first `max_hold_s`, credited at the reading before
|
||||
it, lacks to reach `gap_w`. Returns
|
||||
`(projection, gap seconds filled, unseen seconds filled)`.
|
||||
|
||||
`tail_s` is the age of the held reading: up to `max_hold_s` of it is left
|
||||
as before (the averager credits it once the next reading lands). Past
|
||||
that the gap is still open, nothing is filled and `blindness()` answers
|
||||
as before. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
|
||||
if projection.block_start is None or max_hold_s is None:
|
||||
return projection, 0.0, 0.0
|
||||
wall = float(projection.elapsed_s)
|
||||
tail = min(max(0.0, float(tail_s)), wall)
|
||||
if tail > float(max_hold_s):
|
||||
return projection, 0.0, 0.0
|
||||
covered = wall - uncovered_s(projection)
|
||||
missing = wall - covered - tail
|
||||
if missing <= GAP_TOL_S:
|
||||
missing = 0.0
|
||||
if held_ws <= 0.0:
|
||||
return projection, 0.0, 0.0
|
||||
unseen = min(missing, max(0.0, float(unseen_s)))
|
||||
gap = missing - unseen
|
||||
add_ws = gap * float(gap_w) + unseen * float(unseen_w) + float(held_ws)
|
||||
done = covered + missing
|
||||
return (replace(
|
||||
projection,
|
||||
projected_w=float(projection.projected_w) + add_ws / QUARTER_S,
|
||||
elapsed_w=((float(projection.elapsed_w) * covered + add_ws) / done
|
||||
if done > 0.0 else float(projection.elapsed_w)),
|
||||
covered_frac=(done / wall if wall > 0.0
|
||||
else float(projection.covered_frac))), gap, unseen)
|
||||
|
||||
|
||||
def discharge_permitted(soc, soc_floor) -> str | None:
|
||||
"""SAFETY-24. May the guard size a forced discharge, or why may it not?
|
||||
|
||||
|
||||
@@ -410,6 +410,7 @@
|
||||
"step_in": "The batteries step in above {kw}.",
|
||||
"step_in_would": "The batteries would step in above {kw}.",
|
||||
"period": "This 15-minute period is heading for {kw}.",
|
||||
"period_unmeasured": "Part of this 15-minute period was not measured.",
|
||||
"prices": {
|
||||
"now": "Price now {eur} per kWh, all in.",
|
||||
"today": "Today: lowest {lo} at {lo_at}, highest {hi} at {hi_at}.",
|
||||
|
||||
@@ -347,6 +347,7 @@
|
||||
"step_in": "De batterijen springen bij boven {kw}.",
|
||||
"step_in_would": "De batterijen zouden bijspringen boven {kw}.",
|
||||
"period": "Dit kwartier gaat richting {kw}.",
|
||||
"period_unmeasured": "Een deel van dit kwartier is niet gemeten.",
|
||||
"prices": {"now": "Prijs nu {eur} per kWh, alles inbegrepen.", "today": "Vandaag: laagste {lo} om {lo_at}, hoogste {hi} om {hi_at}.", "none": "Geen prijzen voor vandaag."},
|
||||
"tomorrow": {"known": "De prijzen van morgen zijn binnen.", "unknown": "De prijzen van morgen komen meestal na 13:00."},
|
||||
"region": {"preset": "Heffingen en btw: {region}, cijfers van {year}.", "own": "Heffingen en btw: uw eigen bedrag."},
|
||||
|
||||
@@ -0,0 +1,483 @@
|
||||
"""Runnable check for SAFETY-90: the peak guard goes on after a P1 meter gap.
|
||||
`python3 test_safety90.py`
|
||||
|
||||
A gap past `meter_max_age_s` left seconds the quarter average never counted,
|
||||
so the guard was blind for the rest of the quarter: a HOLD gave 0 W and the
|
||||
quarter raised the month peak (SAFETY-86 rig case 7b: 3964.8 W against a
|
||||
3450 W aim). Now the missed seconds count at `peakguard.gap_w()`, and so do
|
||||
the seconds before the add-on's first reading, with a plain line on the
|
||||
page. Drives the REAL Controller on a lagging battery (10 s), with the P1
|
||||
telegrams stopped for each gap. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md.
|
||||
|
||||
1. N=1 HOLD: gaps of 30 s, 60 s and 5 min mid-quarter land at or under the aim.
|
||||
2. N=2 HOLD, B able: the same.
|
||||
3. N=2 HOLD, B held at its reserve: the same, and B gives nothing (O2).
|
||||
4. A gap across a quarter edge; the house rising during a gap.
|
||||
5. Start-up mid-quarter: the guard runs, the page says what it assumed.
|
||||
6. While the gap lasts the guard is blind as before; no gap, no change.
|
||||
7. fill_gaps() and gap_w() at their boundaries.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import sys
|
||||
import types
|
||||
from datetime import timedelta
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
import app.p1 as p1mod # noqa: E402
|
||||
import app.tariff as tariff # noqa: E402
|
||||
from app import homeview, messages, peakguard # noqa: E402
|
||||
from app.maintenance import HOLD # noqa: E402
|
||||
from app.p1 import make_sample, split_signed # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
from app.tariff import QUARTER_S, Projection # noqa: E402
|
||||
|
||||
fails = []
|
||||
A, B = "inverter-a", "inverter-b"
|
||||
AIM = 3450.0 # peak_cap_w 3500 - peak_margin_w 50
|
||||
TOL = 5.0 # W over the aim a quarter may land (SAFETY-79)
|
||||
CUT = 10.0
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def store(phase_of, n):
|
||||
s = rig._Store()
|
||||
for u in (A, B)[:n]:
|
||||
key = (lambda k: k) if n == 1 else (lambda k, u=u: unit_key(u, k))
|
||||
if u in phase_of:
|
||||
s.data[key("phase")] = phase_of[u]
|
||||
s.data[key("phase_started")] = rig.BASE.isoformat()
|
||||
else:
|
||||
s.data[key("last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def run(house, socs, dur, *, n, gaps=(), start=0.0, lag=10.0, on_cycle=None):
|
||||
"""Rows and controller. A holds full; `socs` are the starting levels
|
||||
(B's follows its power). `gaps`: (t0, t1), no telegram for t0 <= t < t1.
|
||||
`start`: the add-on starts this many s into the run (mid-quarter). The
|
||||
P1 clock is simulated, so a gap really goes stale. `c.truth` is the grid
|
||||
each second, which the quarter really averages."""
|
||||
clock = [0.0]
|
||||
soc, last, truth = dict(socs), [start], []
|
||||
|
||||
def before(c, t0):
|
||||
if on_cycle is not None:
|
||||
on_cycle(c, t0) # the state the last cycle left
|
||||
t = t0 + start
|
||||
clock[0] = t
|
||||
g = c.hass.grid()
|
||||
truth.append((t, g))
|
||||
for u in soc:
|
||||
soc[u] = max(CUT, soc[u] - c.hass.power(u) * (t - last[0])
|
||||
/ 3600.0 / 153.6)
|
||||
last[0] = t
|
||||
if any(a <= t < b for a, b in gaps):
|
||||
return
|
||||
imp, exp = split_signed(g)
|
||||
c.p1.submit(make_sample("ha_signed", imp, exp, phases=1,
|
||||
ingest_ts=rig.BASE + timedelta(seconds=t0),
|
||||
ingest_mono=1e6 + t))
|
||||
|
||||
def power(self, u):
|
||||
st = self.__dict__.setdefault("_plant", {})
|
||||
a, tgt, tl = st.get(u, (0.0, 0.0, self.t))
|
||||
for _ in range(int(round((self.t - tl) / 0.1))):
|
||||
d = self.cmd[u] - tgt
|
||||
tgt += math.copysign(min(abs(d), 80.0), d)
|
||||
a += (tgt - a) * (1 - math.exp(-0.1 / lag))
|
||||
st[u] = (a, tgt, self.t)
|
||||
return 0.0 if self.soc(u, self.t) <= CUT and a > 0 else float(round(a))
|
||||
|
||||
real = (rig._Hass.power, rig.TICK, rig.BASE, p1mod.time)
|
||||
rig._Hass.power, rig.TICK = power, 1.0
|
||||
rig.BASE = real[2] + timedelta(seconds=start)
|
||||
p1mod.time = types.SimpleNamespace(monotonic=lambda: 1e6 + clock[0])
|
||||
try:
|
||||
rows, c = s84.run(
|
||||
n, load=house if callable(house) else (lambda t: house),
|
||||
cheap=False, store=store({A: HOLD}, n), before=before, dur=dur,
|
||||
soc=lambda u, t: soc[u],
|
||||
extra={"maintenance_hold_min": 600})
|
||||
finally:
|
||||
rig._Hass.power, rig.TICK, rig.BASE, p1mod.time = real
|
||||
c.truth = truth
|
||||
return rows, c
|
||||
|
||||
|
||||
def without_fix(fn):
|
||||
"""release/1.0 3ed3302: nothing is filled, so a gap blinds the guard."""
|
||||
real = peakguard.fill_gaps
|
||||
peakguard.fill_gaps = lambda p, **kw: (p, 0.0, 0.0)
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
peakguard.fill_gaps = real
|
||||
|
||||
|
||||
def quarter(c, q):
|
||||
"""What quarter `q` (0 = the run's first) really averages, in W."""
|
||||
return sum(max(g, 0.0) for t, g in c.truth if int(t // QUARTER_S) == q) \
|
||||
/ QUARTER_S
|
||||
|
||||
|
||||
def cmd(r):
|
||||
return dict(r[2])
|
||||
|
||||
|
||||
def mean(rows, u, lo, hi):
|
||||
rs = [cmd(r)[u] for r in rows if lo <= r[0] < hi]
|
||||
return round(sum(rs) / len(rs))
|
||||
|
||||
|
||||
TABLE = []
|
||||
|
||||
|
||||
def case(tag, n, house, socs, gaps, q=0, dur=1800.0):
|
||||
"""One gap case, after and before the fix; prints and records it."""
|
||||
new = run(house, socs, dur, n=n, gaps=gaps)
|
||||
old = without_fix(lambda: run(house, socs, dur, n=n, gaps=gaps))
|
||||
a, b = quarter(new[1], q), quarter(old[1], q)
|
||||
print(f" {tag}: quarter {a:.1f} W (before the fix {b:.1f} W), aim "
|
||||
f"{AIM:.0f}")
|
||||
TABLE.append((tag, n, round(a, 1), round(b, 1)))
|
||||
return new, old, a, b
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. N=1 HOLD, house 6500 W (5500 W for 5 min, so it can be held)")
|
||||
for tag, gap, house in (("30 s", (300, 330), 6500.0),
|
||||
("60 s", (300, 360), 6500.0),
|
||||
("5 min", (300, 600), 5500.0)):
|
||||
(rows, c), _old, a, b = case(f"N=1 gap {tag}", 1, house, {"a": 99.0},
|
||||
[gap])
|
||||
check(f"⭐ N=1, {tag} gap mid-quarter: the quarter lands at or under the "
|
||||
f"aim ({a:.1f} W)", a <= AIM + TOL)
|
||||
if tag != "30 s":
|
||||
check(f"...non-vacuous: before the fix it went over ({b:.1f} W)",
|
||||
b > AIM + 100)
|
||||
check("...and once readings are back the battery gives at least the "
|
||||
"house over the aim",
|
||||
mean(rows, "a", gap[1] + 15, 900) >= house - AIM)
|
||||
check("...the action log says what the gap was counted at",
|
||||
any("PEAK_GUARD_GAP" in e for e in c.events))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. N=2 HOLD (A holding), B able at 60 %, house 6500 W")
|
||||
for tag, gap, house in (("30 s", (300, 330), 6500.0),
|
||||
("60 s", (300, 360), 6500.0),
|
||||
("5 min", (300, 600), 5500.0)):
|
||||
(rows, c), _old, a, b = case(f"N=2 gap {tag}", 2, house,
|
||||
{"a": 99.0, "b": 60.0}, [gap])
|
||||
check(f"⭐ N=2, {tag} gap: the quarter lands at or under the aim "
|
||||
f"({a:.1f} W)", a <= AIM + TOL)
|
||||
if tag != "30 s":
|
||||
check(f"...non-vacuous: before the fix it went over ({b:.1f} W)",
|
||||
b > AIM + 100)
|
||||
check("...B gives first: at its full 2500 W once readings are back",
|
||||
mean(rows, "b", gap[1] + 30, 900) >= 2450)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. N=2 HOLD, B held at 15 % (under its 20 % reserve), house 5500 W "
|
||||
"(4500 W for 5 min: A alone gives 2500 W)")
|
||||
for tag, gap, house in (("30 s", (300, 330), 5500.0),
|
||||
("60 s", (300, 360), 5500.0),
|
||||
("5 min", (300, 600), 4500.0)):
|
||||
(rows, c), (orows, _oc), a, b = case(
|
||||
f"N=2 B held, gap {tag}", 2, house, {"a": 99.0, "b": 15.0}, [gap])
|
||||
check(f"⭐ N=2 B held, {tag} gap: the quarter lands at or under the aim "
|
||||
f"({a:.1f} W)", a <= AIM + TOL)
|
||||
check("⭐ O2: the held B gives nothing once readings are back; the "
|
||||
"holding A gives the need",
|
||||
all(cmd(r)["b"] == 0.0 for r in rows if gap[1] <= r[0] < 900)
|
||||
and mean(rows, "a", gap[1] + 15, 900) >= house - AIM)
|
||||
if tag != "30 s":
|
||||
check("...non-vacuous: before the fix the blind guard left A at 0 W "
|
||||
"and the held B was drawn at 2500 W as last resort",
|
||||
mean(orows, "a", gap[1] + 30, 900) == 0
|
||||
and mean(orows, "b", gap[1] + 30, 900) >= 2450)
|
||||
|
||||
rows, c = run(5500.0, {"a": 99.0, "b": 15.0}, 1000.0, n=2,
|
||||
gaps=[(300, 360), (899, 910)])
|
||||
edge = [(r[0], cmd(r)["a"], cmd(r)["b"]) for r in rows if 900 <= r[0] < 915]
|
||||
print(f" a 60 s gap, then the edge's telegram 11 s late: {edge[:4]}; the "
|
||||
f"second before the edge (O1, not this card): "
|
||||
f"{[(r[0], cmd(r)['a'], cmd(r)['b']) for r in rows if r[0] == 899]}")
|
||||
check("⭐ ...a quarter that had a gap still hands over at its edge (SAFETY-91): "
|
||||
"with the edge's telegram late the held B gives nothing and A keeps "
|
||||
"giving", all(b == 0.0 and a > 1500.0 for _t, a, b in edge))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. a gap across a quarter edge, and a house that rises in a gap")
|
||||
for n, socs in ((1, {"a": 99.0}), (2, {"a": 99.0, "b": 60.0})):
|
||||
(rows, c), _o, a, b = case(f"N={n} gap across the edge", n, 6500.0, socs,
|
||||
[(870, 930)], q=1)
|
||||
check(f"⭐ N={n}: the quarter the readings come back in lands at or "
|
||||
f"under the aim ({a:.1f} W; before the fix {b:.1f} W)",
|
||||
a <= AIM + TOL and b > AIM + 100)
|
||||
check("...the quarter that ended in the gap could not be steered after "
|
||||
"it, and stays under the limit itself",
|
||||
quarter(c, 0) <= 3500.0)
|
||||
|
||||
|
||||
def rising(t):
|
||||
return 3000.0 if t < 320 else 6500.0
|
||||
|
||||
|
||||
for n, socs in ((1, {"a": 99.0}), (2, {"a": 99.0, "b": 15.0})):
|
||||
house = rising if n == 1 else (lambda t: 3000.0 if t < 320 else 5500.0)
|
||||
(rows, c), _o, a, b = case(f"N={n} house rises in a 60 s gap", n, house,
|
||||
socs, [(300, 360)])
|
||||
check(f"⭐ N={n}: the house goes from 3000 W to over the limit during "
|
||||
f"the gap; the import seen after it is counted and the quarter "
|
||||
f"lands at or under the aim ({a:.1f} W)", a <= AIM + TOL)
|
||||
|
||||
for n, socs in ((1, {"a": 99.0}), (2, {"a": 99.0, "b": 15.0})):
|
||||
big = 6500.0 if n == 1 else 5500.0
|
||||
(rows, c), _o, a, b = case(
|
||||
f"N={n} house falls in a 5 min gap", n,
|
||||
lambda t, big=big: big if t < 560 else 2000.0, socs, [(300, 600)])
|
||||
check(f"⭐ N={n}: the house falls to 2000 W just before readings return; "
|
||||
f"the import before the gap (batteries at 0 W) is counted and the "
|
||||
f"quarter lands at or under the aim ({a:.1f} W; before {b:.1f} W, "
|
||||
f"at N=2 by drawing the held B)",
|
||||
a <= AIM + TOL and (n == 2 or b > AIM + 100))
|
||||
|
||||
(rows, c), _o, a, b = case(
|
||||
"N=1 5 min gap at 3000 W, then 60 s gap at 6500 W next quarter", 1,
|
||||
lambda t: 3000.0 if t < 900 else 6500.0, {"a": 99.0},
|
||||
[(300, 600), (1200, 1260)], q=1)
|
||||
check(f"⭐ ...each quarter's gap is counted on its own: a long gap at a low "
|
||||
f"load does not hide a shorter one in the next quarter ({a:.1f} W)",
|
||||
a <= AIM + TOL and sum("PEAK_GUARD_GAP" in e for e in c.events) == 2)
|
||||
|
||||
|
||||
|
||||
def dip(t):
|
||||
return 3000.0 if 450 <= t < 700 else 6500.0
|
||||
|
||||
|
||||
(rows, c), _o, a, b = case("N=1 two gaps, the second at a lower load", 1,
|
||||
dip, {"a": 99.0}, [(300, 360), (500, 560)])
|
||||
at = [float(e.split("counted at ")[1].split(" W")[0]) for e in c.events
|
||||
if "PEAK_GUARD_GAP" in e]
|
||||
check(f"⭐ ...two gaps in one quarter: the second, at a lower load, does not "
|
||||
f"price the first one down (counted at {at}; {a:.1f} W)",
|
||||
a <= AIM + TOL and len(at) == 2 and min(at) >= 6400.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. start-up mid-quarter (the add-on starts 450 s into the quarter)")
|
||||
UI = {}
|
||||
|
||||
|
||||
def grab(c, t):
|
||||
if t == 60.0:
|
||||
UI["unmeasured"] = c.peak_unmeasured_s
|
||||
UI["rows"] = [r for r in c.checks() if r.get("id") == "peak_guard"]
|
||||
UI["en"] = homeview.month_peak(c, c.cycle_at)["line"]
|
||||
homeview._LANG[0] = "nl"
|
||||
try:
|
||||
UI["nl"] = homeview.month_peak(c, c.cycle_at)["line"]
|
||||
finally:
|
||||
homeview._LANG[0] = "en"
|
||||
if t == 453.0:
|
||||
UI["later"] = (c.peak_unmeasured_s,
|
||||
[r for r in c.checks() if r.get("id") == "peak_guard"])
|
||||
|
||||
|
||||
def restored(t_dead, start=450.0):
|
||||
"""TARIFF-01 restores the averager at start-up: 0..t_dead measured at
|
||||
the aim, the held sample at t_dead (the restart's first second)."""
|
||||
def fake(self, averager, now=None):
|
||||
bs = int(rig.BASE.timestamp() - start)
|
||||
averager.restore({"block": bs, "acc": AIM * t_dead,
|
||||
"pp_acc": [AIM * t_dead], "elapsed": t_dead,
|
||||
"last_t": bs + t_dead, "last_net": AIM,
|
||||
"last_pp": [AIM], "phases": 1})
|
||||
self.restore_state = "resumed"
|
||||
return self.restore_state
|
||||
return fake
|
||||
|
||||
|
||||
def startup(house, socs, n, *, t_dead=None, on_cycle=None):
|
||||
"""The add-on starts 450 s in. While it was down the batteries were at
|
||||
0 W (the ESP32 watchdog), so the meter saw the house: the quarter is
|
||||
that, or the restored part at the aim, plus what this run measured."""
|
||||
real = tariff.PeakTracker.restore
|
||||
if t_dead is not None:
|
||||
tariff.PeakTracker.restore = restored(t_dead)
|
||||
try:
|
||||
rows, c = run(house, socs, 455.0, n=n, start=450.0,
|
||||
on_cycle=on_cycle)
|
||||
finally:
|
||||
tariff.PeakTracker.restore = real
|
||||
pre = 450.0 * house if t_dead is None else (
|
||||
t_dead * AIM + (450.0 - t_dead) * house)
|
||||
return rows, c, (pre + sum(max(g, 0.0) for t, g in c.truth if t < 900)) \
|
||||
/ QUARTER_S
|
||||
|
||||
|
||||
for n, socs, house in ((1, {"a": 99.0}, 5000.0),
|
||||
(2, {"a": 99.0, "b": 15.0}, 4500.0)):
|
||||
rows, c, land = startup(house, socs, n, on_cycle=grab if n == 1 else None)
|
||||
orows, _oc, old = without_fix(lambda: startup(house, socs, n))
|
||||
TABLE.append((f"N={n} start-up mid-quarter", n, round(land, 1),
|
||||
round(old, 1)))
|
||||
check(f"⭐ N={n}: the first 450 s (house {house:.0f} W, batteries at 0 W) "
|
||||
f"count at the import seen first; the quarter lands at or under "
|
||||
f"the aim ({land:.1f} W, before the fix {old:.1f} W)",
|
||||
land <= AIM + TOL and (n == 2 or old > AIM + 100))
|
||||
if n == 2:
|
||||
check("...and the held B gives nothing (O2 at start-up); before the "
|
||||
"fix it was drawn at 2500 W",
|
||||
all(cmd(r)["b"] == 0.0 for r in rows if 1 <= r[0] < 450)
|
||||
and mean(orows, "b", 30, 450) >= 2450)
|
||||
check("...non-vacuous: before the fix A gave 0 W for the quarter",
|
||||
mean(orows, "a", 30, 450) == 0)
|
||||
|
||||
rows, c, land = startup(6500.0, {"a": 99.0}, 1)
|
||||
check(f"⭐ N=1, house 6500 W: more than the battery can make up; A gives its "
|
||||
f"full 5000 W and the alarm says so ({land:.1f} W)",
|
||||
mean(rows, "a", 30, 450) >= 4900
|
||||
and any("PEAK_GUARD_SATURATED" in e for e in c.events))
|
||||
|
||||
for t_dead in (300.0, 390.0, 440.0):
|
||||
rows, c, land = startup(6500.0, {"a": 99.0}, 1, t_dead=t_dead)
|
||||
TABLE.append((f"N=1 restart, down {450 - t_dead:.0f} s", 1,
|
||||
round(land, 1), round(without_fix(lambda: startup(
|
||||
6500.0, {"a": 99.0}, 1, t_dead=t_dead))[2], 1)))
|
||||
check(f"⭐ restart mid-quarter, down {450 - t_dead:.0f} s at house "
|
||||
f"6500 W (the restored reading's held 30 s topped up too): the "
|
||||
f"quarter lands at or under the aim ({land:.1f} W)",
|
||||
land <= AIM + TOL)
|
||||
|
||||
rows, c = run(6500.0, {"a": 99.0}, 1350.0, n=1, start=450.0,
|
||||
gaps=[(1200, 1260)])
|
||||
a = quarter(c, 1)
|
||||
TABLE.append(("N=1 start-up, then 60 s gap next quarter", 1, round(a, 1),
|
||||
round(quarter(without_fix(lambda: run(
|
||||
6500.0, {"a": 99.0}, 1350.0, n=1, start=450.0,
|
||||
gaps=[(1200, 1260)]))[1], 1), 1)))
|
||||
check(f"...the start-up assumption stays in its own quarter: a 60 s gap in "
|
||||
f"the next one is counted as a gap and lands at or under the aim "
|
||||
f"({a:.1f} W)", a <= AIM + TOL)
|
||||
|
||||
print(f" page: {UI.get('rows')}\n EN {UI.get('en')!r}\n"
|
||||
f" NL {UI.get('nl')!r}")
|
||||
check("⭐ the page says plainly that part of the period was not measured, "
|
||||
"in English and Dutch",
|
||||
UI.get("unmeasured", 0) > 400
|
||||
and UI["rows"][0]["text"] == messages.row_peak_guard_unmeasured()
|
||||
and UI["en"].startswith("Part of this 15-minute period was not "
|
||||
"measured.")
|
||||
and UI["nl"].startswith("Een deel van dit kwartier is niet gemeten."))
|
||||
check("...and stops saying it in the next quarter",
|
||||
UI["later"][0] == 0.0 and UI["later"][1][0]["text"]
|
||||
!= messages.row_peak_guard_unmeasured())
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n6. while the gap lasts, and with no gap at all")
|
||||
LIVE = {}
|
||||
|
||||
|
||||
def live(c, t):
|
||||
if t == 350.0:
|
||||
LIVE["g"] = c.peak_guard
|
||||
|
||||
|
||||
run(6500.0, {"a": 99.0}, 400.0, n=1, gaps=[(300, 360)], on_cycle=live)
|
||||
check("⭐ 50 s into a gap the guard is blind as before (floor 0 W, no "
|
||||
"charging): nothing is filled while the gap is open",
|
||||
LIVE["g"].blind is not None and LIVE["g"].floor_w == 0.0)
|
||||
for n, socs, house in ((1, {"a": 99.0}, 6500.0),
|
||||
(2, {"a": 99.0, "b": 60.0}, 6500.0),
|
||||
(2, {"a": 99.0, "b": 15.0}, 5500.0)):
|
||||
rows, c = run(house, socs, 1000.0, n=n)
|
||||
orows, _ = without_fix(lambda: run(house, socs, 1000.0, n=n))
|
||||
check(f"⭐ N={n}, meter never drops: every row is identical with and "
|
||||
f"without the fix, and nothing is filled",
|
||||
rows == orows and not any("PEAK_GUARD_GAP" in e for e in c.events))
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n7. fill_gaps() and gap_w() at their boundaries")
|
||||
T0 = rig.BASE
|
||||
|
||||
|
||||
def proj(wall, covered, held=1000.0, acc_w=1000.0):
|
||||
return Projection(projected_w=(acc_w * covered + held * (QUARTER_S - wall))
|
||||
/ QUARTER_S, elapsed_w=acc_w, elapsed_s=wall,
|
||||
covered_frac=covered / wall, complete=False,
|
||||
block_start=T0, held_w=held)
|
||||
|
||||
|
||||
def fill(p, tail, unseen=0.0, gw=4000.0, uw=3450.0):
|
||||
return peakguard.fill_gaps(p, tail_s=tail, max_hold_s=30.0,
|
||||
unseen_s=unseen, gap_w=gw, unseen_w=uw)
|
||||
|
||||
|
||||
p = proj(400.0, 300.0) # 100 s uncounted
|
||||
f, g, u = fill(p, 10.0)
|
||||
check("90 s missed (100 s uncounted less a 10 s tail): counted at gap_w, "
|
||||
"the tail left as before, no longer blind",
|
||||
g == 90.0 and u == 0.0
|
||||
and abs(f.projected_w - (p.projected_w + 90.0 * 4000.0 / QUARTER_S))
|
||||
< 1e-9 and abs(peakguard.uncovered_s(f) - 10.0) < 1e-9
|
||||
and peakguard.blindness(f, 30.0, False) is None
|
||||
and peakguard.blindness(p, 30.0, False) is not None)
|
||||
check("tail exactly max_hold_s: filled; one past it: the gap is open, "
|
||||
"nothing filled",
|
||||
fill(p, 30.0)[1] == 70.0 and fill(p, 30.001) == (p, 0.0, 0.0))
|
||||
f, g, u = fill(p, 10.0, unseen=60.0)
|
||||
check("unseen seconds come first and count at the aim, the rest at gap_w",
|
||||
u == 60.0 and g == 30.0
|
||||
and abs(f.projected_w - (p.projected_w + (60 * 3450.0 + 30 * 4000.0)
|
||||
/ QUARTER_S)) < 1e-9)
|
||||
check("nothing missed (or under 1 ms): the projection object is returned "
|
||||
"unchanged",
|
||||
fill(proj(400.0, 400.0), 0.0)[0] is not None
|
||||
and fill(proj(400.0, 400.0), 0.0) == (proj(400.0, 400.0), 0.0, 0.0)
|
||||
and fill(proj(400.0, 399.9995), 0.0)[1] == 0.0)
|
||||
f, g, u = fill(proj(400.0, 400.0), 0.0)
|
||||
f2 = peakguard.fill_gaps(proj(400.0, 400.0), tail_s=0.0, max_hold_s=30.0,
|
||||
unseen_s=0.0, gap_w=4000.0, unseen_w=3450.0,
|
||||
held_ws=9000.0)
|
||||
check("held_ws (the gap's first 30 s topped up) is added even when nothing "
|
||||
"is missing any more",
|
||||
g == 0.0 and abs(f2[0].projected_w - f.projected_w - 10.0) < 1e-9)
|
||||
z = peakguard.fill_gaps(Projection(0, 0, 0, 0, False, T0, 0), tail_s=0.0,
|
||||
max_hold_s=30.0, unseen_s=0.0, gap_w=4000.0,
|
||||
unseen_w=3450.0, held_ws=9000.0)
|
||||
check("the first instant of a block (0 s elapsed) with held_ws: no division "
|
||||
"by zero", abs(z[0].projected_w - 10.0) < 1e-9)
|
||||
check("no open block: unchanged (blindness says so)",
|
||||
fill(Projection(0, 0, 0, 0, False, None, 0), 0.0)[1:] == (0.0, 0.0))
|
||||
check("gap_w(): the highest of the limit and the imports seen, None skipped",
|
||||
peakguard.gap_w(3500, None, 3000.0) == 3500.0
|
||||
and peakguard.gap_w(3500, 6500.0, None) == 6500.0
|
||||
and peakguard.gap_w(3500, 3000.0, 4500.0) == 4500.0
|
||||
and peakguard.gap_w(3500) == 3500.0)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n case N quarter W before W aim")
|
||||
for tag, n, a, b in TABLE:
|
||||
print(f" {tag:<34}{n} {a:>9.1f} {b:>9.1f} {AIM:.0f}")
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED")
|
||||
sys.exit(1)
|
||||
print("all SAFETY-90 checks passed")
|
||||
Reference in New Issue