Ships release 0.15.0 (`3ed3302`, merged via #173) to `master`, which Home Assistant installs from.
Owner go: 2026-10-05 ("Go deploy").
- Pinned to `3ed3302` through the branch `deploy-0.15.0`.
- `predeploy_check.py --deployed-version 0.14.0` with a fresh export of the live options (two-inverter roster, Watchdog on): see the deploy report.
- Changelog: `## 0.15.0` in `goodwe_controller/CHANGELOG.md` (SAFETY-94, SAFETY-97, SAFETY-58; CI-14).
🤖 Generated with [Claude Code](https://claude.com/claude-code)
The stale-reading gate counted its 35 s from the register's last change, so
after a rest the first read after a new command tripped it (SAFETY-58; live
2026-10-03, four trips 1 s after the command). It now counts only the time
the command asked the register to move.
At N=1 the refusal engaged after 12 frozen cycles if the reading was under
100 W at that moment, which a battery reversing through its lag passes at a
1 s meter. The refusal now needs the N>1 evidence at every roster size: under
100 W, one way, for 12 cycles spanning 22 s, restarting when the reading
moves 50 W towards the ask.
DECISIONS/SAFETY-94-lagging-battery.md; test_safety94.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- test_safety94 part 4: time under 250 W is not counted; a command that
swaps direction every cycle is never refusal evidence; a reading moving
away from the ask does not restart the evidence. These kill review
mutants R1, R3 and R6, which survived the PR's tests.
- DECISIONS: at N=1 a battery with B's standby offset no longer latches
a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after
35/d s of wall time.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
B's power reading shows -95 to -118 W at idle (standby draw), so the
|reading| < 100 W refusal band never held a refusing B: never at N=2,
and since SAFETY-94's shared rule not at N=1 either (review F1).
Each unit now learns its idle reading (app/idle.py): only while control
runs, the unit is not refused/stale/tripped and its command has stayed
within 50 W for 120 s; first value a 120 s mean, then a 30 min follow;
samples beyond 250 W dropped, value clamped to 250 W; saved per unit and
restored. The shared refusal evidence, compute()'s N=1 engage and end,
the unit refusal ends, the stale-path refusal and SAFETY-42's "parked"
test are centred on it. Until learned it is 0 W, the rule as it was.
Refusing B caught at N=1 28/28/65 s and N=2 24/24/60 s (1/2/5 s
meters), before never; refusing A unchanged. Healthy B with its offset,
SAFETY-94's scenarios, 96 runs: 0 stale, 0 refused. Live replay: 0.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
At a 5 s meter a register frozen at rest on B trips the stale gate before
the 12-cycle evidence; its refusal must be centred on B's idle reading,
or the site stops and re-trips instead of refusing B.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
The N=1 stale-path refusal and SAFETY-42's parked test are centred on the
idle reading; learning stops while control is stopped or the sign watchdog
has latched. Each had no check (review mutants X7, X8, X13, X14).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Owner decision 2026-10-04 (review R1). A wrong idle reading more than
about 100 W off hid every refusal on that battery. Clamped under the band,
the band keeps 0 W +-25 W, so a battery reading about 0 W while refusing is
caught whatever was learned or restored. Samples are still taken to 250 W.
Beyond about +-170 W of idle a battery behaves as in 0.14.0.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from
SAFETY-94/97, no option change). New `## 0.15.0` section with the contents
since 0.14.0 (cf705a9#171, 3129dae#172) and the known issues.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Ships release 0.15.0 (
3ed3302, merged via #173) tomaster, which Home Assistant installs from.Owner go: 2026-10-05 ("Go deploy").
3ed3302through the branchdeploy-0.15.0.predeploy_check.py --deployed-version 0.14.0with a fresh export of the live options (two-inverter roster, Watchdog on): see the deploy report.## 0.15.0ingoodwe_controller/CHANGELOG.md(SAFETY-94, SAFETY-97, SAFETY-58; CI-14).🤖 Generated with Claude Code