adminandClaude Opus 5.5 badea3cb2d UX-13 P0 review: keep unread keys, back off a failed entity read
checks / unit (pull_request) Successful in 9m30s
infra-pin / fresh (pull_request) Successful in 1s
- uimodel: editing a listed inverter keeps the stored flat keys, and a
  region of "own" keeps a stored price_taxes_profile (both were dropped).
- haentities: a failed read also waits CACHE_S, so polls while Home
  Assistant is down do not queue one 10 s read each.
- ui_text: the Flanders preset names its DSO, and the help says
  Wallonia and Brussels have no figures yet. REGION_PRESETS cites the card.
- tests: decode of a reversed solar row, both kept keys, the backoff.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 23:39:43 +02:00
glenn schrooyenandClaude Opus 5.5 15627c38a6 UX-13 P0: layout table, page<->options derivation, warning tier, entity list
checks / unit (pull_request) Successful in 9m32s
infra-pin / fresh (pull_request) Successful in 1s
The foundation for the new settings page. No visible UI change.

- app/uilayout.py: screen -> group -> part -> field for every option in
  config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
  scale, step, entity kind, show conditions, Simple/wizard placement and
  "applies after a restart". Ranges stay in the schema, words in
  translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
  inverter vs the list, solar rows, static_profile from simple prices, a
  year-stamped region preset for the levies figure, and an OPT-11 hook for
  arbitrage_enabled that changes nothing yet). Unchanged derivations write
  the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
  a note when a list is passed; config_notes() adds checks that need live
  data (missing entity, a kW sensor read as W, a limit below this month's
  peak). /config/validate returns them as "notes". No refusal changed: 261
  recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
  hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
  with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
  code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
  the TEST-23 option files and config.yaml defaults), test_haentities, a
  warning-tier part in test_validate; test_messages scans notes and
  ui_text; test_pv and test_selfconfig part 7 widened on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 23:11:31 +02:00
admin 652097abde Merge pull request 'SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min' (#141) from SAFETY-52-refused-hold into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 18:21:21 +02:00
adminandClaude Opus 5.5 3c0f2b9669 SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
checks / unit (pull_request) Successful in 9m22s
infra-pin / fresh (pull_request) Successful in 1s
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
  own 100 W answer, not below saturation_w: a battery derated to 100-499 W
  was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
  or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
  reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
  DECISIONS record carries the traced cause of the replay's extra trips.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 18:11:42 +02:00
glenn schrooyenandClaude Opus 5.5 1d33265aac test_price: grade the Why row of the same render, not a second read of why_words
checks / unit (pull_request) Successful in 9m20s
infra-pin / fresh (pull_request) Successful in 1s
Since UX-10 the waiting sentence counts its seconds when it is read, so the
second read could cross a second boundary on a loaded runner ("1 second" in
the row, "2 seconds" in the check). CI run 953 on this PR failed that way;
test_price.py passes locally on the same tree.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 17:04:55 +02:00
glenn schrooyenandClaude Opus 5.5 1f97c7652f SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Failing after 9m32s
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).

test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 16:43:27 +02:00
admin d1f7e3336e Merge pull request 'UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG' (#140) from UX-11-short-safety-lines into release/1.0
infra-pin / fresh (push) Successful in 2s
Merge UX-11: short safety log lines, figures to DEBUG and events (#140)
2026-09-27 14:31:05 +02:00
adminandClaude Opus 5.5 3c298af3d8 UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
checks / unit (pull_request) Successful in 9m7s
infra-pin / fresh (pull_request) Successful in 1s
- After a restart, each restored stop (direction per inverter and site,
  delivery, circulation) also writes its saved reason to the action log.
  log_level defaults to info and events starts empty, so the DEBUG
  evidence alone left the figures only in state.json.
- A flapping meter (ha_signed under a flat load, 42-97 s between changes)
  logs at most one WARNING/INFO pair per 10 minutes, with the episodes in
  between at DEBUG.
- LONG_LINE_OK refuses any key whose text is a safety reason.
- test_watchdog keeps the byte pin beside the meaning pin, since the text
  did not change.
- DOCS says the DEBUG line needs log_level debug.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 14:21:05 +02:00
glenn schrooyenandClaude Opus 5.5 c628099e69 UX-11: the meter WARNING names the limit only, as 'over 30 seconds'
checks / unit (pull_request) Successful in 9m4s
infra-pin / fresh (pull_request) Successful in 2s
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30
seconds': the age is 30.4 s, which rounds to the limit. The limit alone is
always true at the moment the line is logged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:49:17 +02:00
glenn schrooyenandClaude Opus 5.5 29837dfaa7 UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- Every WARNING/ERROR line that reported a safety reason (direction, delivery,
  stuck meter, stale reading, peak guard, circulation, over-rating) now ends in
  the reason's code (messages.reason_code()). The reason itself, figures and
  limits included, is on a DEBUG line right after it and in the action log.
- The reasons and state.json are unchanged, so an old state file loads and
  shows the same way: every saved reason opens with its code.
- test_messages part 6 checks every WARNING+ line at 25 words as logged; nine
  non-safety families are listed with a reason and capped. The byte pin in
  test_watchdog now pins the meaning, in order.
- The meter logs one WARNING per quiet episode, and INFO when back, so the red
  row's "the add-on log shows why" holds. The Why line past the hold names
  the missing reading. Action log: "25 engagements", "Shadow mode off: ...".

No trigger, latch, threshold, log level, notification id, cadence, row colour
or banner order changed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:34:30 +02:00
admin c4032ebc21 Merge pull request 'CI: bump infra pin to d637d0b (admin/goodwe#61, UX-10)' (#139) from pin-bump-d637d0b into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 12:30:15 +02:00
glenn schrooyenandClaude Opus 5.5 2f1627e287 CI: bump infra pin to d637d0b (admin/goodwe#61, UX-10)
checks / unit (pull_request) Successful in 9m5s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 12:19:51 +02:00
admin 2b14b88cb4 Merge pull request 'UX-10: the last plain-language leftovers (log lines, two table rows, 'Why: Other', red at 0 s)' (#138) from UX-10-plain-leftovers into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 12:18:22 +02:00
39 changed files with 3650 additions and 119 deletions
+1 -1
View File
@@ -1,2 +1,2 @@
# The admin/goodwe commit CI tests against. Bump: set to the full SHA of admin/goodwe release/1.0 HEAD (README.md, "CI and the infra pin").
ecd3864d9376a990c267dfb399eb2dae4e56c76b
d637d0b1b13f1b863dc47e445e2ca4cf4a82fe10
+1 -1
View File
@@ -7,7 +7,7 @@ This applies to everything a home owner or installer reads: notifications, phone
- **Body**: **one sentence** of at most 25 words, saying what happened and what to do. A **red alarm** may use up to **3 sentences** (70 words, each sentence at most 30 words), so that no action a person must take is lost.
- **Details**: the last line links to the add-on documentation and names the section with the rest: `Details: add-on documentation, section "<title>" under Notifications.` Background, figures, reason codes and history go there or into the log, never into the body.
- **Status row**: one sentence of at most 15 words. A **red** row may use up to 3 sentences (30 words), like a red alarm. It shows the live numbers the reader acts on and never an HA entity id. **Banner**: at most 12 words. **Refusal**: at most 30 words, naming the setting by its label and then its key, as `messages.setting()` writes it: “Inverter rating” (max_w), or “Inverter rating” for inverter-b (inverters.max_w) for one inverter in the list. **Option name**: at most 6 words, not counting the group prefix. **Option description**: at most 30 words. Where a value comes from belongs in DOCS.md.
- **Log line** (WARNING/ERROR): one line, at most 25 words, with the numbers that matter. The reasoning goes on a DEBUG line. Log lines stay in English and are not translated. A reason text a line quotes (`%s`) keeps its reason code (`OUTPUT_CLAMP`, `STALE_READING`), because that is the evidence an installer searches for. The reason itself has the shape of a red alarm: at most 3 sentences of at most 30 words. The line as logged has no semicolon, banned word, capitals, "1 times" or "(s)". `test_messages.py` part 6 builds every such reason with the real code and checks it. A line that repeats every cycle is DEBUG. INFO lines carry no section numbers, ISO timestamps or capitals.
- **Log line** (WARNING/ERROR): one line of at most 25 words **as logged**, with any built text filled in. Log lines stay in English and are not translated. A line that reports a safety reason gives one plain sentence and the reason's code (`STALE_READING`, `OUTPUT_CLAMP`), the evidence an installer searches for. The reason itself, with its figures and limits, goes on a DEBUG line right after it and into the action log, never onto the WARNING/ERROR line. It keeps the shape of a red alarm: at most 3 sentences of at most 30 words. The line as logged has no semicolon, banned word, capitals, "1 times" or "(s)". `test_messages.py` part 6 builds every such text with the real code and checks it, and lists the few non-safety families still over 25 words. A line that repeats every cycle is DEBUG. INFO lines carry no section numbers, ISO timestamps or capitals.
- **Refusal length is counted as shown**: a setting placeholder counts as its label and key, and the long cases are driven through the validator (`test_messages.py` part 3).
- **Event line** under the buttons: the plain words of `messages.hint()`, like a green row. The add-on's own action log stays technical and is not shown on the page. Installers read it as `events` in the `status` JSON.
- **Sentences**: one idea each, active voice, present tense, with nothing nested in brackets and no semicolons (a semicolon is a second sentence in disguise). These translate well into Dutch and French.
@@ -0,0 +1,110 @@
# SAFETY-52 - a battery that refuses is asked for 0 W
**Decided 2026-09-27 by the owner, on the phase A plan (option D3). All four
questions answered yes.**
## The defect
At the BMS cut-out the battery gives ~0 W whatever it is asked. The saturation
freeze (`control.py`, `frozen`) then holds the request where it stood, and its
SAFETY-13 exit cannot fire, because a reading of ~0 against a large ask lies
inside the interval a limit can produce. The request stood at +5000 W for
11.87 h on 2026-09-06 and at +1940 W for 3 h 55 m on the bus on 2026-09-19. It
moved again only when the grid error changed sign. SAFETY-48's lead cap only
changes where `i_w` parks (one slew step ahead instead of at the rail). When
the request moved after the reading went flat, the stale-reading gate won
instead and ran SAFETY-59's ~70 s trip cycle.
## What was decided
1. **A refused direction is held at 0 W**, reason `battery refuses`. It engages
in `compute()` when the freeze has held `SETTLE_CYCLES` and the reading is
below `REFUSED_BELOW_W` (100 W, the probe's own answer) against an ask beyond
`saturation_w`. The drop to 0 skips
the slew limit (it only removes an ask nobody meets). The direction is
carried like `sat_count` (`refused=`, `Decision.refused`).
2. **A 200 W probe every 15 minutes, 34 s long** (`PROBE_W`, `PROBE_EVERY_S`,
`PROBE_S`; twice `BATT_OBLIGED_S`). A reading of at least 100 W in the held
direction ends the refusal, during a probe or not. 200 W is below `freshness.MOVE_W` (250 W), so a probe cannot arm
the gate. The clock is main.py's `now_mono`; `compute()` stays clockless.
3. **A gate trip while the loop is frozen on a ~0 W reading is a refusal** for
control (`Controller._refusal_from_stale`). This is what stops the ~70 s
cycle. The log keeps SAFETY-56's two-explanation wording.
4. **No SoC in the loop.** SAFETY-25 Option A stands. Nothing reads SoC.
Other exits: the loop wants the other direction (charge is accepted at the
floor), control stopped or started, another writer on the wire (the arbiter
reseed). A gap in the readings keeps the refusal, because the gate's own stop is
what seeds it.
**One inverter only.** At N>1, OPT-09's `pack` limit already closes an empty
battery's discharge end and moves its share. There, a one-unit gate trip must
not refuse the site. `compute()` is passed `refused=None` there, and that path
is release/1.0's law unchanged (the `i_w=None` equivalence sweep in
`test_control.py` still holds).
## Evidence
`test_refusal.py` drives the real Controller and gate (the 09-06 and 09-19
shapes, recovery with no sign change, the probe cadence, every exit).
`tools/replay_refusal.py` replays the 16-day capture, same model as
`replay_recorded_loop.py`, and should be read for deltas:
| plant | law | gate trips | request >1 kW above delivery | longest held | import / export kWh | worst 15-min |
|---|---|---|---|---|---|---|
| fitted | old | 85 | 113.3 h | 16.57 h | 112.0 / 35.2 | 3434 W |
| fitted | new | 130 (133 after review) | 11.4 h | 0.21 h | 112.3 / 35.4 | 3456 W |
| offset 0 W | old | 1010 | 102.2 h | 16.58 h | 112.0 / 35.2 | 3434 W |
| offset 0 W | new | 85 | 6.1 h | 0.33 h | 111.9 / 35.1 | 3434 W |
**Traced in review (#141).** The +22 W worst quarter is the old law's worst
quarter too. There the old law stands at +2060 W on a pack giving 0 W, and the
new law asks 0 W, which the fitted plant answers with its -22 W offset: 22 W
charged from the grid. The fit above the floor reads `batt = cmd - 28 W`, so a
real inverter asked 0 W may do the same. Of the 71 new-law trips with no
old-law trip within 2 min, 59 come 85-97 s after an answered probe. The offset has lifted the modelled pack
just above its floor, the probe is answered, control ramps, the pack empties
again mid-ramp, and the gate trips, which re-seeds the hold. The other 12
follow an other-direction exit the same way. On a site this is one
`STALE_READING` ERROR line per answered probe at most, and only on a battery
that answers a probe and then cuts out again. Catching the re-cut before the
gate needs a faster engage than `SETTLE_CYCLES`, which accuses a healthy slow
battery, so it is left to SAFETY-58/59. After the review changes below the
fitted-plant row reads 133 trips (the delivery exit now also catches answers
that arrive after the probe window); the other figures are unchanged. Rejected alternatives and their figures are in
the phase A plan: bounding the integrator by demand made the worst quarter
+541 W worse or cycled the gate 3368 times, and an SoC envelope needs the
configured floor to be right and needs SoC.
## Review changes (#141)
- **"Gives nothing" is below 100 W, not below 500 W.** At `saturation_w` a
battery derated to 100-499 W (cold, a tapering battery) was held at 0 W for
~93 % of the time: 300 W derated gave 86 Wh in 4 h against 1 200 Wh on the
old law. The capture has 0.11 h in that band, so the replay does not move.
- **Any delivery ends the hold, not only an answered probe.** With
`meter_poll_s: 1` the 12 cycles last 12 s, less than a healthy battery's
reading lag (up to `BATT_OBLIGED_S`, 17 s). That engaged on a healthy step and
held it for 15 min. Now the late reading ends it within seconds (2 s held in
`test_refusal.py` part 5b).
- **N>1 is stated as a limit in DOCS.** The pack limit there covers an empty
battery only when its cut-out level is configured right.
## Not covered
A battery that gives a steady part of the ask (e.g. a 500 W keep-alive) is a
genuine limit (SAFETY-13 case a) and still holds its request.
## What SAFETY-58 and SAFETY-59 must take into account
- **SAFETY-58** (the first read after a rest trips at once): a probe never arms
the gate (200 < 250 W), but the refusal seeding reads the trip. If 58 delays
the first verdict, the seed arrives later. The 09-19 shape then needs the
compute-side engagement (12 cycles) to win, which it does only while the
request stands still. Keep `test_refusal.py` part 4 green.
- **SAFETY-59** (DOCS says a ~70 s pattern proves a failed register): with this
change a refusing battery no longer produces the pattern at one inverter. The
DOCS text should say so, and that the `battery refuses` reason is the
discriminator the add-on now has. At N>1 the old pattern can still occur.
- If either changes `MOVE_W`, `PROBE_W` must stay below it.
`test_refusal.py` part 2 checks the inequality.
@@ -78,3 +78,15 @@ The allowlist is empty and its cap is 0 (43 → 0). Every WARNING and ERROR line
7. **Review: the line as logged gets the shape too.** Part 6 first checked the quoted reason alone, so a title, a 2-sentence reason and two tails still logged as 4 sentences ("Power request too high …: OUTPUT_CLAMP: … +5000 W. The command this cycle was +1000 W. Control is still running. Cut back 1 time so far."). Part 6 now also checks the whole line: at most 3 sentences, none over 30 words. The wrappers became one sentence each, the circulation and peak guard reasons two, and `STALE_READING`'s fixed limits moved from the reason to a DEBUG line beside the ERROR (its release clause stays, pinned by test_freshness). The clamp lines for one inverter are pinned at 30 words at most: `OUTPUT_CLAMP: computed +9000 W, cut to the +5000 W rating, command now +2000 W`. Several clamped inverters read as one sentence of asked/sent pairs; which limit bound each is on its own action-log row and in the notification. Totals above 30 words remain on the direction, delivery, frozen-meter and stale lines (up to 74 words). Shortening them is a follow-up: the direction and delivery reasons are also persisted in state.json, and the direction one is pinned byte-for-byte in test_watchdog.
8. **Home Assistant 400 while it loads** now reads "Home Assistant refused number.set_value for number.x (error 400, no details). The entity may still be loading, or the value is out of range." A body with more than "400: Bad Request" is still quoted. Still WARNING, still once a minute, still a failed write.
9. **Witness** (admin/goodwe): the resolved push says "after no answers from … to …", as the resolved card does. The YAML with every title and message stripped is identical.
# UX-11: safety log lines give the code, the figures go to DEBUG
**Unchanged:** every trigger, latch, threshold and alarm log level (the WARNING and ERROR lines stay), every notification id and cadence, every row colour and the banner cascade. No notification is added.
1. **One plain sentence and the code.** A WARNING/ERROR line that reports a safety reason (direction, delivery, stuck meter, stale reading, peak guard, circulation, over-rating) now ends in the reason's code, taken by `messages.reason_code()`. The reason itself, figures and limits included, is on a DEBUG line logged right after it ("Evidence for inverter-a: …"), and the action log entry carries it as before. Part 6 checks that pairing in the code. Circulation and the clamp lines were not among the five named, but they break the same 25-word rule, so they follow the same pattern. The clamp numbers stay in the notification (phase 2a item 3).
2. **The reasons and `state.json` are unchanged.** `reason` stays the evidence text, so what is saved has the same format as before. An old state file therefore loads and displays like a new one: every saved reason has opened with its code since it was first written (checked in the git history), and that code is all the ERROR line reads. The saved text goes on the DEBUG line. A stop saved without a reason shows `REASON_NOT_SAVED`. `test_messages.py` part 7 restarts from a state file holding the old long texts. `test_watchdog.py` pins the meaning (the code first, then command, reading, time and both limits, in that order) and, since the text did not change, still the bytes.
3. **The 25-word rule is checked as logged.** Part 6 fails any WARNING+ line over 25 words with its built text filled in. Nine non-safety families still run long (tariff plan words, price feed reasons, the state migration report, write refusals and claim scope errors that only a software fault raises, maintenance, trading gate and price history reasons). They are listed with a reason in `LONG_LINE_OK`, capped at 9, and a listed family that gets shorter fails until it is removed. Shortening them is a follow-up.
4. **The meter row's "the add-on log shows why" is now true.** When the meter goes quiet past its limit, the add-on logs one WARNING per episode, not one per cycle, and an INFO line when readings return. A meter that flaps (on `ha_signed` a healthy meter under a flat load can go 42–97 s between changes) logs at most one such pair per 10 minutes, and the episodes in between go to DEBUG. This is a new log line, not a new alarm: it has no notification and changes no decision.
5. **The Why line past the 15 s hold** names the missing reading ("No usable meter reading for over 15 seconds: 0 W", or the battery power or level of an inverter), instead of "A reading is missing: 0 W".
6. **Action log:** "25 engagement(s)" is "25 engagements", and "SHADOW MODE OFF - …" is "Shadow mode off: …". "SHADOW MODE ON" was not named in the card and is left as it is.
7. **Review: after a restart the figures go on the action log too.** `log_level` defaults to `info`, so the DEBUG evidence line is not seen by default, and `events` starts empty. Each restored stop (direction per inverter and site, delivery, circulation) now also writes its saved reason to the action log ("FAILSAFE inverter-a, saved before the restart: …"), and the page's event line gets the same plain words the live stop gives. `LONG_LINE_OK` also refuses a key whose text is a safety reason, not only a `reason_code` key.
@@ -0,0 +1,69 @@
# UX-13 — one layout table, and why UI code may now name an option key
**Status: DECIDED 2026-09-27 (owner approved the UX-13 design and mockup).**
Card 6ab979852f3eca02fb40f69e. Amends [[UX-02]] §3.1. Design note and
mockup: `goodwe-session/UX-13-design.md`, `UX-13-mockup.html`.
## 1. What UX-02 said, and why it no longer fits
UX-02 built the configuration panel from the Supervisor's schema, so
`app/configui.py` contains "no option key, no label and no rule", and
test_selfconfig.py part 5 checks that the page script names no key. That kept
a second copy of the option surface from drifting, and it is why the panel is
a flat list of fields in schema order.
UX-13 needs things a schema cannot say: groups and sub-groups, a slider in kW
for a value stored in W, a picker for an entity, a field shown only for one
meter source, locked measured values, a Simple view and a setup wizard. It
also needs page fields that are not options at all: one inverter card that is
stored as six flat keys, solar rows that become `pv_entity` or `pv_entities`,
a contract and two prices that become `static_profile` JSON, and a region
that becomes the levies figure. None of that can be read off the schema, so
some code has to name option keys.
## 2. The decision
Option keys may appear in UI code in exactly two files:
- **`app/uilayout.py`**, the layout table: screen → group → part → field, with
control, unit, display scale, step, entity kind, when it is shown, whether it
is on the Simple view or a wizard step, and whether it applies now or after a
restart. Every option in `config.yaml` is a field, `DERIVED` or `HIDDEN`,
exactly once.
- **`app/uimodel.py`**, the derivations the table names: `options_to_ui()` and
`ui_to_options()`. It may name only the keys it writes.
What UX-02 made authoritative stays authoritative:
- **Ranges** come from the schema (`uilayout.range_of()`); the table writes
none. A unit holds no digit.
- **Labels and help** come from `translations/*.yaml` by key. Page-only fields,
group titles and choices are in `app/ui_text/*.json`, held to STYLE by
test_messages.py.
- **Rules** stay in `validate.py`. It gains a warning tier (`validate.Note`,
"warn" or "info") for the page. A note never blocks a save, and passing the
notes list does not change the refusals returned.
- **The stored blob** is still the one truth. The page model carries the stored
values of every derived key (`keep`). A derivation whose page fields are
unchanged writes those values back untouched, so a blob the page cannot
express survives a save of another field.
## 3. How it is held
- test_uilayout.py fails when `config.yaml` gains an option, or an inverter
field, that the table does not place. It also checks that uimodel.py names
only the keys it writes and that web.py and haentities.py name none.
- test_uimodel.py round-trips options → page model → JSON → options for every
validator call the suite made at 652097a (`scenarios/ux13/`), the TEST-23
option files and config.yaml's defaults. All must be identical.
- `tools/ux13_validator_calls.py compare` runs those calls through the old and
new validator. At P0: 261 calls, 158 refused, no refusal changed.
- test_selfconfig.py part 5 still checks the old page script; P1 moves the page
into `app/static/` and the same check applies there.
## 4. What this costs
The table is a second place that knows the option surface, which UX-02 set
out to avoid. The cost is bounded by the coverage test: an option added to
config.yaml and not placed here fails CI, rather than silently missing from
the page. Changing a key's type or range needs no change here.
+37 -7
View File
@@ -526,7 +526,7 @@ accumulator is doing:
| `Loop integrator lead` | W | that value minus **the command it was computed against**, i.e. the command the previous cycle left standing |
| `Loop reason` | — | the law's own word for this cycle |
`Loop reason` takes one of eight values:
`Loop reason` takes one of ten values:
| value | what happened |
|---|---|
@@ -538,6 +538,27 @@ accumulator is doing:
| `saturated-freeze` | the inverter is not following, so the command's magnitude may fall but not rise |
| `freeze-released` | the freeze had run out of plant-shaped explanations and the command was let move again |
| `not-running` | control is stopped **and** shadow mode is off, so the loop did not run |
| `battery refuses` | the battery gave less than 100 W for 12 cycles (a minute at a 5-second meter) while asked for more than 500 W, so the add-on asks 0 W in that direction (see below) |
| `battery probe` | the add-on asks 200 W to test whether a refusing battery gives power again |
**When the battery refuses.** At its cut-out level the battery gives nothing,
whatever it is asked. The add-on then asks 0 W instead of repeating its last
request, and the `Why` row reads *The battery refuses to give power: 0 W*. Every
15 minutes it asks 200 W for about half a minute. Control resumes as soon as
the battery gives 100 W or more, when the grid needs charging instead, and when
control is stopped or started. 200 W is below the 250 W the stale-reading check
needs, so a test never trips it. A battery that gives some power, even 100 W,
is not refusing and keeps its request.
⚠️ **One inverter only.** With several inverters this hold is off. There, the
battery level limit moves an empty battery's share to the others, but only if
its “Battery cut-out level” matches where the battery really stops. A battery
that refuses at another level, or for another reason (cold, a battery fault),
can still hold its last request until the grid starts to export.
*For installers:* SAFETY-52. The event log reads `BATTERY REFUSES …` and
`BATTERY REFUSES ENDED: …`, and the INFO line ends in `BATTERY_REFUSES`.
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures.
⚠️ **`Loop reason` is not the `Why` row on the status page, and the two will
often disagree.** `Why` is the *arbiter's* answer in words — *Keeping the grid
@@ -3095,8 +3116,11 @@ stop control on the add-on page.
This part is for installers. The texts live in `app/messages.py` and follow
`STYLE.md`. Every notification keeps a fixed `notification_id`, so a repeat
replaces the card. The full figures and reason codes are on the ERROR or
WARNING line of the add-on log.
replaces the card. The ERROR or WARNING line of the add-on log names the
reason code. The full figures are in `events` in the `status` JSON, also for a
stop restored after a restart, and on the DEBUG line logged right after it.
That DEBUG line only shows with “Log level” (log_level) set to `debug`; the
default `info` hides it.
| Title | Severity | id | Card |
|---|---|---|---|
@@ -3223,8 +3247,9 @@ ends. That row says how to clear it.
### For installers: status page
The texts are in `app/messages.py`. The full figures of any alarm are on its
ERROR or WARNING line in the add-on log.
The texts are in `app/messages.py`. An alarm's ERROR or WARNING line names its
reason code, and its full figures are on the DEBUG line right after it and in
`events` in the `status` JSON.
- **Stuck-meter check: off** needs `meter_source: homewizard_local` (label
“Where the meter reading comes from”), a `max_w` (“Inverter rating”) and a
@@ -3246,9 +3271,14 @@ ERROR or WARNING line in the add-on log.
check** SAFETY-42.
- **Month peak** and **15-minute periods measured** are TARIFF-01 and
TARIFF-13. The store's state at start is the INFO line `Month peak store:
…`, and the peak guard's full reason is on its log line.
…`, and the peak guard's full reason is on the DEBUG line after its ERROR.
- ***name*: battery power reading stopped changing** is SAFETY-37/56/57. The
ERROR line carries the full `STALE_READING` reason and when it clears.
ERROR line says when it clears and names `STALE_READING`. The full reason,
with both possible causes, is on the DEBUG line after it.
- **Meter: no reading for …** (red): the add-on logs one WARNING when the
meter goes quiet, "No meter reading for …", and an INFO line when readings
return, at most once every 10 minutes. Past `stale_input_s` the **Why**
line names the missing reading.
- The table at the top: **Why** is `messages.why()`, the arbiter's answer in
words (`Resolution.explain()` stays on the log). **Tariff**, **Price
history**, **Arbitrage** and **Shadow mode** keep every figure they had
+58 -1
View File
@@ -265,6 +265,34 @@ _SAT_COUNT_CAP = SETTLE_CYCLES + 1 # 13
# `slew_limit_w()` and therefore with the rail.
SLEW_LEAD_STEPS = 1
# ---------------------------------------------------------------------------
# SAFETY-52. A BATTERY THAT REFUSES IS ASKED FOR 0 W, NOT HELD AT ITS LAST ASK.
#
# At the BMS cut-out the pack delivers ~0 W whatever it is asked, so the
# saturation freeze below holds the command where it stood (the recorded
# 09-06 case: +5000 W for 11.87 h) until the grid error changes sign. The
# freeze's own exit cannot help: a reading of ~0 against a large ask is inside
# the interval a limit can produce. So a refused DIRECTION is held at 0 W,
# carried between cycles like `sat_count`, and left again when the loop wants
# the other direction, when a small probe is answered, or when the caller
# resets it (stop, start, another writer). The record is DECISIONS/SAFETY-52.
#
# PROBE_W is below freshness.MOVE_W (250 W) on purpose: a probe that small can
# never arm the stale-reading gate, so it cannot start the gate's ~70 s cycle.
# test_refusal.py pins the inequality. The cadence and length are the owner's
# 2026-09-27 answer (every 15 minutes) and freshness.BATT_OBLIGED_S twice over
# (17 s is how long a healthy reading needs to show a command).
REFUSED = "battery refuses"
PROBING = "battery probe"
PROBE_W = 200.0
PROBE_ANSWER_W = PROBE_W / 2
# "Gives nothing" is below the probe's own answer, not below `saturation_w`: a
# pack derated to 100-499 W is a limit, and at 500 W it kept ~7 % of its power
# (review of #141). The capture's refusals read -4 W.
REFUSED_BELOW_W = PROBE_ANSWER_W
PROBE_EVERY_S = 900.0
PROBE_S = 34.0
@dataclass(frozen=True)
class Tuning:
@@ -346,6 +374,9 @@ class Decision:
i_bound_w: float = 0.0
requested_w: float = 0.0
clamped_w: float = 0.0
# SAFETY-52. The refused direction to carry back in (+1 discharge, -1
# charge, 0 none), or None when the caller does not carry it.
refused: int | None = None
def slew_limit_w(tuning: Tuning) -> float:
@@ -442,6 +473,8 @@ def compute(
tuning: Tuning,
sat_count: int = 0,
i_w: float | None = None,
refused: int | None = None,
probe: bool = False,
) -> Decision:
"""One control cycle. A cycle is one meter update (~5 s on a HomeWizard P1).
@@ -449,6 +482,9 @@ def compute(
`grid_w` net grid power, + = importing
`actual_w` what the inverter reports it is doing, + = discharging
`i_w` the carried integrator, or None to seed it from `prev_w`
`refused` SAFETY-52's carried refused direction, or None to leave it out
(the `i_w=None` equivalence path does)
`probe` the caller's clock says a refused direction may try PROBE_W now
"""
reason = "tracking"
@@ -739,6 +775,27 @@ def compute(
target = min(target, prev_w) if prev_w > 0 else max(target, prev_w)
reason = "saturated-freeze"
# --- SAFETY-52: a refused direction is held at 0 W ----------------------
# Engages only where the freeze has held for SETTLE_CYCLES and the unit
# delivers ~nothing: a reading below REFUSED_BELOW_W against an ask beyond
# `saturation_w` is a refusal, not a slow plant. The drop to 0 skips the slew
# limit because it only removes an ask the battery is not meeting.
if refused is not None:
if (refused == 0 and frozen and sat_count >= SETTLE_CYCLES
and abs(prev_w) > tuning.saturation_w
and abs(actual_w) < REFUSED_BELOW_W):
refused = 1 if prev_w > 0 else -1
if refused and refused * i_w < 0:
refused = 0 # the loop wants the other way
elif refused and refused * actual_w >= PROBE_ANSWER_W:
refused = 0 # it delivers: a probe answered,
# or a slow reading arriving
elif refused:
wants = refused * i_w > 0
i_w = 0.0
target = refused * PROBE_W if probe and wants else 0.0
reason = PROBING if probe and wants else REFUSED
# --- quantise ----------------------------------------------------------
# 10 W. The register is 1 W and the inverter reports at 1 W, but its
# response lands on a coarser ladder (~17.6 W measured at ~900 W, consistent
@@ -749,7 +806,7 @@ def compute(
return Decision(float(target), sat_count, frozen, reason, float(i_w),
i_clamped, clamped, float(i_bound_w), float(want),
float(clamped_w))
float(clamped_w), refused)
def maintenance_charge_floor(
+91
View File
@@ -0,0 +1,91 @@
"""UX-13: Home Assistant's entities, for the settings page's entity picker.
A read of `GET /api/states` through the add-on's own session (hass.states()),
cached for 30 s and trimmed to what a picker shows. Nothing here writes, so
UX-02 §6 holds. When Home Assistant does not answer, the last good list is
served with its age, or an empty one that says why: the route never fails.
"""
import asyncio
import time
CACHE_S = 30.0
DOWN_TEXT = "Home Assistant is not answering, so the entity list is empty."
STALE_TEXT = "Home Assistant is not answering, so this list may be old."
_POWER_UNITS = ("mW", "W", "kW", "MW", "GW", "TW")
_ENERGY_UNITS = ("Wh", "kWh", "MWh", "GWh")
def row(state: dict) -> dict | None:
"""One state object -> {entity_id, name, state, unit, device_class}."""
if not isinstance(state, dict) or not isinstance(state.get("entity_id"), str):
return None
attrs = state.get("attributes") if isinstance(state.get("attributes"), dict) else {}
return {"entity_id": state["entity_id"],
"name": str(attrs.get("friendly_name") or state["entity_id"]),
"state": state.get("state"),
"unit": attrs.get("unit_of_measurement"),
"device_class": attrs.get("device_class")}
def matches(r: dict, kind: str) -> bool:
"""Is `r` what a picker of this kind offers first? `kind` is one of
uilayout.ENTITY_KINDS; "" or "any" offers everything."""
unit, cls = r.get("unit"), r.get("device_class")
if kind in ("power", "power_w"):
return cls == "power" or unit in _POWER_UNITS
if kind == "energy":
return cls == "energy" or unit in _ENERGY_UNITS
if kind == "pct":
return unit == "%"
if kind == "number":
return r["entity_id"].startswith(("number.", "input_number."))
return True
class EntityCache:
"""The last entity list read from Home Assistant, at most CACHE_S old."""
def __init__(self, hass, clock=time.monotonic):
self.hass = hass
self.clock = clock
self.rows: dict | None = None
self.read_at: float | None = None
self.tried_at: float | None = None
self._lock = asyncio.Lock()
async def get(self) -> tuple[dict | None, float | None]:
"""(rows by entity id, age in s), or (None, None) if never read."""
async with self._lock: # one HA read however many pickers ask
now = self.clock()
# A failed read also waits CACHE_S, so polls while HA is down do
# not queue one 10 s read each behind this lock.
if self.tried_at is None or now - self.tried_at >= CACHE_S:
self.tried_at = now
states = await self.hass.states()
if states is not None:
rows = (row(s) for s in states)
self.rows = {r["entity_id"]: r for r in rows if r}
self.read_at = now
if self.read_at is None:
return None, None
return self.rows, now - self.read_at
def peek(self) -> dict | None:
"""The cached rows if they are fresh, without asking Home Assistant."""
if self.read_at is None or self.clock() - self.read_at >= CACHE_S:
return None
return self.rows
async def payload(self, kind: str = "") -> dict:
"""The route's JSON: matching entities first, then the rest."""
rows, age = await self.get()
if rows is None:
return {"available": False, "text": DOWN_TEXT, "entities": []}
ordered = sorted(rows.values(), key=lambda r: r["entity_id"])
first = [dict(r, match=True) for r in ordered if matches(r, kind)]
rest = [dict(r, match=False) for r in ordered if not matches(r, kind)]
out = {"available": True, "age_s": round(age, 1), "entities": first + rest}
if age >= CACHE_S:
out["text"] = STALE_TEXT
return out
+27
View File
@@ -18,6 +18,7 @@ SUPERVISOR_API = "http://supervisor"
BAD_STATES = ("unknown", "unavailable", "none", "")
# What the Supervisor's proxy answers while Home Assistant restarts.
UNAVAILABLE = (502, 503, 504)
STATES_TIMEOUT_S = 10 # UX-13's entity list, like every other read here
class Outage:
@@ -113,6 +114,32 @@ class HomeAssistant:
return None
return obj
async def states(self) -> list | None:
"""Every entity's state object (`GET /api/states`), or None when Home
Assistant does not answer. A read only (UX-13 entity picker)."""
try:
async with self.session.get(
f"{CORE_API}/states", headers=self._headers,
timeout=STATES_TIMEOUT_S
) as resp:
if resp.status in UNAVAILABLE:
OUTAGE.down("api", f"error {resp.status}",
f"read all states: {resp.status}")
return None
OUTAGE.up("api")
resp.raise_for_status()
obj = await resp.json()
except aiohttp.ClientConnectionError as err:
OUTAGE.down("api", "no connection", f"read all states: {err}")
return None
except (aiohttp.ClientError, TimeoutError, ValueError) as err:
self._moan("read:*", "Reading the entity list failed: %s", err)
return None
if not isinstance(obj, list):
self._moan("shape:*", "The entity list is not a list: %.80r", obj)
return None
return obj
async def number(self, entity_id: str, invert: bool = False) -> float | None:
"""Numeric state, or None. Never substitutes a default."""
obj = await self.state(entity_id)
+229 -34
View File
@@ -39,6 +39,7 @@ from .arbiter import (
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY,
Claim, Resolution, actuator_for, resolve,
)
from . import control as _ctl
from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk
from .delivery import (
DELIVERY_OPTION_DEFAULTS, DeliveryConfig, UnitDelivery,
@@ -119,6 +120,9 @@ WRITE_BUDGET_S = 4.0
# restart this add-on (measured on TEST-23), so a latched alarm is re-asserted
# this often. Why: goodwe docs/DECISIONS.md, SAFETY-34.
REANNOUNCE_S = 300.0
# UX-11 review: a quiet meter logs at most one WARNING this often, because on
# `ha_signed` a healthy meter under a flat load can go 42-97 s between changes.
METER_QUIET_REPEAT_S = 600.0
_mono = time.monotonic # patched by the checks; asyncio keeps the real one
# --------------------------------------------------------------------------- #
@@ -238,6 +242,10 @@ def why_key(winner: str, claims) -> str:
disagreement"). A failsafe with no claim of its own is the arbiter's "no
claim was made", or main.py's refusal to split the power ("unsplit").
"""
if winner == "loop":
# SAFETY-52: a loop holding a refused direction says so.
return next((c.reason for c in claims if c.source == "loop"
and c.reason in (_ctl.REFUSED, _ctl.PROBING)), winner)
if winner in ("safety", "failsafe"):
return next((c.reason for c in claims
if c.source == winner and c.kind == "set"),
@@ -611,10 +619,21 @@ class Controller:
self._grade_store_migration(store)
for inv in self.inverters:
if inv.sign_wd.tripped:
# UX-11: the plain sentence and the code. The saved reason,
# with its figures, is on the DEBUG line beside it.
_LOG.error("%s stays at 0 W after the restart because its "
"power went the wrong way, so find out why before "
"you start control. %s.", inv.name,
"you start control: %s.", inv.name,
messages.reason_code(inv.sign_wd.reason))
_LOG.debug("Evidence for %s: %s.", inv.name,
inv.sign_wd.reason or "(reason not recorded)")
# UX-11 review: `events` starts empty and DEBUG is off by
# default, so the saved figures go on the action log too.
saved = inv.sign_wd.reason or messages.NO_REASON_SAVED
self.log_event(f"FAILSAFE {inv.name}, saved before the "
f"restart: {saved}",
hint=messages.hint("stop_restored",
unit=inv.name))
# --- SAFETY-42 + SAFETY-34 -------------------------------------------
# ⚠️ A LATCH THAT DOES NOT ACT, WHICH IS THE ONE ASYMMETRY WITH EVERY
@@ -637,8 +656,15 @@ class Controller:
_LOG.error(
"%s is still marked as not delivering after the restart "
"while control keeps running, and only stopping and "
"starting control clears this. %s.",
inv.name, inv.delivery_wd.reason or "(reason not recorded)")
"starting control clears this: %s.",
inv.name, messages.reason_code(inv.delivery_wd.reason))
_LOG.debug("Evidence for %s: %s.", inv.name,
inv.delivery_wd.reason or "(reason not recorded)")
saved = inv.delivery_wd.reason or messages.NO_REASON_SAVED
self.log_event(f"NOT DELIVERING {inv.name}, saved before the "
f"restart: {saved}",
hint=messages.hint("not_delivering",
unit=inv.name))
# --- SAFETY-30: THE SITE HALF OF THE SIGN CHECK ----------------------
# ⚠️ ONE PER SITE, BESIDE THE ONE PER INVERTER, AND ARMED ONLY AT N>=2.
@@ -669,8 +695,13 @@ class Controller:
_LOG.error(
"After the restart every inverter stays at 0 W, as the total "
"power went the wrong way, so find out why before starting "
"control. %s.",
self.site_sign_wd.reason or "(reason not recorded)")
"control: %s.", messages.reason_code(self.site_sign_wd.reason))
_LOG.debug("Evidence for the site: %s.",
self.site_sign_wd.reason or "(reason not recorded)")
self.log_event("FAILSAFE site, saved before the restart: "
+ (self.site_sign_wd.reason
or messages.NO_REASON_SAVED),
hint=messages.hint("site_direction"))
# And the per-unit detectors are told which question they are asking,
# here as well as in `cycle()`. `checks()` and the status page read
# `inv.sign_wd.cfg` and can be called before the first cycle has run, so
@@ -722,8 +753,14 @@ class Controller:
_LOG.error(
"After the restart every inverter stays at 0 W, as the "
"inverters worked against each other, so find out why before "
"starting control. %s.",
self.circ_wd.reason or "(reason not recorded)")
"starting control: %s.",
messages.reason_code(self.circ_wd.reason))
_LOG.debug("Evidence for the site: %s.",
self.circ_wd.reason or "(reason not recorded)")
self.log_event("CIRCULATING POWER, saved before the restart: "
+ (self.circ_wd.reason
or messages.NO_REASON_SAVED),
hint=messages.hint("circulating"))
# SAFETY-03. The output clamp's alarm - see clamp.py for why the clamp
# itself is the cheap half.
@@ -893,6 +930,12 @@ class Controller:
self.target = 0.0
self.sat_count = 0
self.i_w = 0.0 # the loop's integrator, carried between cycles
# SAFETY-52. The direction the battery refuses (+1 / -1 / 0), carried
# like `i_w`, and when the refusal (or its last probe) started.
self.batt_refused = 0
self.batt_refused_at = None
self._now_mono = None
self._refusal_auto = False
# TEL-10. What the last cycle's loop did, kept for publication. Seeded
# to the SAME values the "stopped or blind" branch of `cycle()` writes,
# because before the first cycle the loop has not run - which is the
@@ -929,6 +972,11 @@ class Controller:
self.following = False
self.reason = "starting"
self.why_words = "Starting"
# UX-11: has this meter episode's WARNING been logged? See read_inputs.
self._meter_quiet_logged = False
# ...when the last WARNING was, and whether this episode logged one.
self._meter_quiet_warned = None
self._meter_quiet_loud = False
# ALLOC-01. The allocation record from the last resolution, or None
# before the first cycle. ⚠️ IT IS KEPT SO THAT SOMETHING CAN GATE ON
# IT: SAFETY-28 puts the write path behind this record, and DEV-02 reads
@@ -1021,6 +1069,69 @@ class Controller:
self.loop_pass_mono = None
# -- helpers -------------------------------------------------------------
# --- SAFETY-52: a battery that refuses is asked for 0 W ------------------
def _refusal_probe(self) -> bool:
"""True while a refused direction may try `PROBE_W` (every 15 min)."""
if (not self.batt_refused or self.batt_refused_at is None
or self._now_mono is None):
return False
held = self._now_mono - self.batt_refused_at
if held >= _ctl.PROBE_EVERY_S + _ctl.PROBE_S:
self.batt_refused_at = self._now_mono
return False
return held >= _ctl.PROBE_EVERY_S
def _refusal_start(self, sign: int, evidence: str) -> None:
self.batt_refused = sign
self.batt_refused_at = self._now_mono
self.log_event(f"BATTERY REFUSES {evidence}",
hint=messages.hint("battery_refuses"))
_LOG.info("The battery refuses to give power, so the add-on asks 0 W "
"and tries %.0f W every %.0f minutes: BATTERY_REFUSES.",
_ctl.PROBE_W, _ctl.PROBE_EVERY_S / 60)
_LOG.debug("Evidence: BATTERY_REFUSES: %s.", evidence)
def _refusal_end(self, why: str) -> None:
if not self.batt_refused:
return
self.batt_refused, self.batt_refused_at = 0, None
self.log_event(f"BATTERY REFUSES ENDED: {why}",
hint=messages.hint("battery_gives"))
_LOG.info("The battery refusal ends, control asks for power again: %s.",
why)
def _refusal_update(self, decision, asked_w, batt_w, probe) -> None:
"""Follow `compute()`'s carried refused direction, and say so."""
now = decision.refused or 0
if now and not self.batt_refused:
self._refusal_start(now, f"asked {asked_w:+.0f} W, the battery "
f"gave {batt_w:+.0f} W for "
f"{decision.sat_count} cycles")
elif self.batt_refused and not now:
gave = self.batt_refused * batt_w >= _ctl.PROBE_ANSWER_W
self._refusal_end("the probe was answered" if gave and probe
else "the battery gives power" if gave
else "the grid now asks the other direction")
def _refusal_from_stale(self, inv, now_mono) -> None:
"""A stale-reading stop while the loop is frozen on ~0 W is a refusal.
Only at one inverter: with several, one empty battery must not stop the
site (OPT-09's pack limit moves its share to the others).
"""
t = self.tuning
standing = inv.standing_w()
if (len(self.inverters) == 1 and (self.auto or self.shadow)
and not self.batt_refused
and self.sat_count >= t.saturation_cycles
and inv.batt_fresh.held is not None
and abs(inv.batt_fresh.held) < _ctl.REFUSED_BELOW_W
and abs(standing) > t.saturation_w):
self._now_mono = now_mono
self._refusal_start(1 if standing > 0 else -1,
f"stale reading {inv.batt_fresh.held:+.0f} W "
f"while asked {standing:+.0f} W")
def log_event(self, msg: str, hint: str | None = None) -> None:
"""`msg` goes on the action log, the add-on's own technical record.
`hint` is `messages.hint()`'s plain words for the same event, and is
@@ -1229,8 +1340,9 @@ class Controller:
first.store_set("sign_tripped", True)
_LOG.error(
"%s is set to 0 W again because an older saved safety stop was "
"found, so find out why before you start control. %s.",
first.name, first.sign_wd.reason)
"found, so find out why before you start control: %s.",
first.name, messages.reason_code(first.sign_wd.reason))
_LOG.debug("Evidence for %s: %s.", first.name, first.sign_wd.reason)
_LOG.debug(
"SAFETY-02 latch guard: the pre-DEV-02 flat key says the "
"sign-disagreement failsafe is latched and no inverter came up "
@@ -1726,6 +1838,18 @@ class Controller:
return all(inv.soc is not None and inv.batt is not None
for inv in self.inverters)
def missing_reading(self) -> str:
"""UX-11: the first reading `inputs_ok` finds missing, in words."""
if self.grid is None or not self.inverters:
return "meter"
for inv in self.inverters:
of = "" if len(self.inverters) == 1 else f" from {inv.name}"
if inv.batt is None:
return f"battery power{of}"
if inv.soc is None:
return f"battery level{of}"
return "input"
# -- io ------------------------------------------------------------------
@property
def pv_roster(self) -> tuple:
@@ -1790,6 +1914,7 @@ class Controller:
"""
o = self.o
now_mono = freshness.monotonic() if now_mono is None else float(now_mono)
self._now_mono = now_mono
if self.p1_enabled:
# ⚠️ P1 is the only authoritative measurement of what the utility
# sees (§5.1). When it is stale this is None, which falls into the
@@ -1885,6 +2010,34 @@ class Controller:
horizon_h=float(price_option(o, "price_horizon_h")),
provider=provider_configured(o), max_age_s=TARIFF_MAX_AGE_S)
# UX-11: the red meter row says "the add-on log shows why", so a meter
# that goes quiet gets one WARNING per episode, not one per cycle. It
# is a log line only: no notification, and nothing it decides.
# A flapping meter logs at most one WARNING per METER_QUIET_REPEAT_S,
# and the episodes in between go to DEBUG.
if self.p1_enabled:
if (self.p1.stale and not self._meter_quiet_logged
and self.p1.published_age_s > self.p1.max_age_s):
self._meter_quiet_logged = True
now = _mono()
self._meter_quiet_loud = (
self._meter_quiet_warned is None
or now - self._meter_quiet_warned >= METER_QUIET_REPEAT_S)
if self._meter_quiet_loud:
self._meter_quiet_warned = now
_LOG.warning("No meter reading for over %s, so control "
"waits and then sets the battery to 0 W.",
messages.seconds(self.p1.max_age_s))
else:
_LOG.debug("No meter reading for over %s again.",
messages.seconds(self.p1.max_age_s))
elif not self.p1.stale and self._meter_quiet_logged:
self._meter_quiet_logged = False
if self._meter_quiet_loud:
_LOG.info("Meter readings are back.")
else:
_LOG.debug("Meter readings are back.")
if self.inputs_ok:
if self.inputs_bad_since is not None:
self.log_event("inputs recovered",
@@ -1925,6 +2078,7 @@ class Controller:
if inv.batt_fresh.stale and not was_stale:
self.log_event(f"STALE {inv.name}: " + inv.batt_fresh.reason,
hint=messages.hint("battery_stuck", unit=inv.name))
self._refusal_from_stale(inv, now_mono)
# ⚠️ SAFETY-57 REWROTE THE LAST SENTENCE OF THIS LINE AND NOTHING
# ELSE IN IT. The escape clause used to read "It clears itself the
# moment the register reports a different value", full stop - and
@@ -1953,13 +2107,16 @@ class Controller:
# learns to skim it.
# UX-08 2d: plain, with SAFETY-57's escape clause kept as an
# ordered pair (time, then power), and the reason still in `%s`.
# UX-10: one sentence, then the reason's two. Its limits are on
# the DEBUG line below, to keep the line within 3 sentences.
# UX-11: one sentence and the code. The reason, with SAFETY-56's
# two explanations and its figures, and the limits are on the
# DEBUG lines below and in the action log.
_LOG.error("%s: battery power reading stopped changing, set to "
"0 W until it changes, or %.0f s after the command "
"drops below %.0f W. %s.",
"drops below %.0f W: %s.",
inv.name, inv.batt_fresh.bound.release_s,
inv.batt_fresh.bound.move_w, inv.batt_fresh.reason)
inv.batt_fresh.bound.move_w,
messages.reason_code(inv.batt_fresh.reason))
_LOG.debug("Evidence for %s: %s.", inv.name, inv.batt_fresh.reason)
_LOG.debug("%s: the limits are unchanged over %.0f s, a command "
"over %.0f W and a move by over %.0f W.", inv.name,
inv.batt_fresh.bound.unchanged_s,
@@ -2491,8 +2648,10 @@ class Controller:
self.log_event(f"FAILSAFE {inv.name}: " + inv.sign_wd.reason,
hint=messages.hint("direction", unit=inv.name))
_LOG.error("%s is set to 0 W until control is started, "
"because its power went the wrong way. %s.",
inv.name, inv.sign_wd.reason)
"because its power went the wrong way: %s.",
inv.name, messages.reason_code(inv.sign_wd.reason))
_LOG.debug("Evidence for %s: %s.", inv.name,
inv.sign_wd.reason)
# ⚠️ THE SITE'S OWN STANDING COMMAND, WHICH IS THE SUM OF THE UNITS'.
# SAFETY-07 and SAFETY-18 both grade a SITE quantity - the quarter-hour
# average at the grid connection, and a meter that has stopped moving
@@ -2540,7 +2699,10 @@ class Controller:
hint=messages.hint("site_direction"))
_LOG.error("Every inverter is set to 0 W until control is "
"started, because the total power went the wrong "
"way. %s.", self.site_sign_wd.reason)
"way: %s.",
messages.reason_code(self.site_sign_wd.reason))
_LOG.debug("Evidence for the site: %s.",
self.site_sign_wd.reason)
# --- SAFETY-31, AND IT RUNS BESIDE SAFETY-02 FOR THE SAME REASON -----
# Evaluated EVERY cycle, unconditionally, above the "inputs missing but
@@ -2572,8 +2734,9 @@ class Controller:
hint=messages.hint("circulating"))
_LOG.error(
"Every inverter is set to 0 W until control is started, "
"because the inverters worked against each other. %s.",
self.circ_wd.reason)
"because the inverters worked against each other: %s.",
messages.reason_code(self.circ_wd.reason))
_LOG.debug("Evidence for the site: %s.", self.circ_wd.reason)
# --- SAFETY-42, AND IT RUNS HERE FOR SAFETY-02's AND SAFETY-31's REASON
# Evaluated EVERY cycle, unconditionally, ABOVE the "inputs missing but
@@ -2680,8 +2843,10 @@ class Controller:
unit=inv.name))
_LOG.error(
"%s is not delivering while control keeps running, and "
"only stopping and starting control clears this. %s.",
inv.name, inv.delivery_wd.reason)
"only stopping and starting control clears this: %s.",
inv.name, messages.reason_code(inv.delivery_wd.reason))
_LOG.debug("Evidence for %s: %s.", inv.name,
inv.delivery_wd.reason)
_LOG.debug(
"SAFETY-42 reports and does not act: commanding a unit "
"that is not listening achieves nothing (HW-01), and the "
@@ -3251,6 +3416,12 @@ class Controller:
# loop should be. It is safe because the loop's `prev_w` is
# `self.target`, which the end of this method re-seeds to what is
# actually standing on the wire.
# SAFETY-52: a refusal learned while control ran does not survive a
# stop or a start (shadow mode keeps the loop running when stopped).
if bool(self.auto) != self._refusal_auto:
self._refusal_auto = bool(self.auto)
self._refusal_end("control started" if self.auto
else "control stopped")
if (self.auto or self.shadow) and self.inputs_ok:
# ⚠️ prev is the ARBITER's last output, not the loop's own last
# wish. If something outranked the loop, that is what the hardware
@@ -3268,6 +3439,13 @@ class Controller:
# stale period as power.
if self.loop_w is None or self.target != self.loop_w:
self.i_w = self.target
# SAFETY-52: another writer overrode the loop, so a refusal learned
# against the loop's own ask no longer describes the wire. A gap
# (`loop_w` None: blind or stopped) keeps it: the stale-reading stop
# is what seeds it, and dropping it there restarts the ~70 s cycle.
if self.loop_w is not None and self.target != self.loop_w:
self._refusal_end("another writer")
probe = self._refusal_probe()
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
# The anti-windup test inside compute() is
# `abs(prev_w - actual_w) > saturation_w`, and `prev_w` is the SITE
@@ -3296,6 +3474,10 @@ class Controller:
tuning=self.tuning,
sat_count=self.sat_count,
i_w=self.i_w,
# SAFETY-52 at one inverter only: with several, OPT-09's pack
# limit already closes an empty battery's discharge end.
refused=self.batt_refused if len(self.inverters) == 1 else None,
probe=probe,
)
if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
self.log_event(f"saturation freeze ({self.target:.0f} W vs "
@@ -3304,6 +3486,7 @@ class Controller:
self.sat_count = decision.sat_count
self.i_w = decision.i_w
self.loop_w = decision.target_w
self._refusal_update(decision, loop_prev, site_batt, probe)
# --- TEL-10 ------------------------------------------------------
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
# THE CARD IS. `self.i_w` is carried between cycles and published
@@ -3554,9 +3737,14 @@ class Controller:
# UX-10: `why_key()` maps a safety winner to its claim's reason, and
# every key it can return has words in messages.WHY_WINNER.
_why = why_key(resolution.winner, claims)
self.why_words = messages.why(_why, resolution.target_w,
resolution.bound_by,
contradiction=resolution.contradiction)
if _why == "inputs missing" and not resolution.contradiction:
# UX-11: past the hold, say which reading is missing.
self.why_words = messages.why_missing(self.missing_reading(),
stale_after)
else:
self.why_words = messages.why(
_why, resolution.target_w, resolution.bound_by,
contradiction=resolution.contradiction)
# --- DEV-02: EACH INVERTER IS TOLD ITS OWN SHARE ---------------------
# ⚠️ ITS OWN SHARE, NEVER THE SITE TARGET. `resolution.shares` is the
# allocator's answer and `sum(shares) + unmet_w == round(target_w)` is
@@ -3743,8 +3931,8 @@ class Controller:
shadow.why(self.o, control_started=self.auto))
elif not first:
self.log_event(
"SHADOW MODE OFF - the battery is being controlled again, "
f"resuming from {shadow.WIRE_W:.0f} W",
"Shadow mode off: the add-on controls the battery again, "
f"starting from {shadow.WIRE_W:.0f} W",
hint=messages.hint("shadow_off"))
_LOG.info(
"Shadow mode is off, so the add-on controls the battery "
@@ -3856,8 +4044,9 @@ class Controller:
# write-path engagements and 2 loop-side ones.
if engaged and not engaged_write:
tag = f"{CLAMP_REASON} episode {self.clamp_wd.episodes}"
row = (f"{tag}: {self.clamp_wd.engagements} engagement(s) - "
f"{reason}")
row = (f"{tag}: "
f"{messages.count(self.clamp_wd.engagements, 'engagement')}"
f" - {reason}")
if self.events and tag in self.events[0]:
stamp = self.events[0].split(" ", 1)[0]
self.events[0] = f"{stamp} {row}"
@@ -3871,8 +4060,9 @@ class Controller:
# WARNING and a plainly titled notice, same cadence. Its OWN id, so
# it can never replace a BUG SIGNAL notice still on screen.
_LOG.warning("The battery gives less than asked: %s. Held back %s "
"so far.", self.clamp_wd.reason,
"so far.", messages.reason_code(self.clamp_wd.reason),
messages.times(self.clamp_wd.engagements))
_LOG.debug("Evidence: %s.", self.clamp_wd.reason)
_LOG.debug("A short hold after a large load or solar step is "
"normal. If it lasts, check that the battery follows "
"its commands.")
@@ -3881,8 +4071,9 @@ class Controller:
return
_LOG.error(
"Power request too high, a software fault: %s. Cut back %s so "
"far, control runs on.",
self.clamp_wd.reason, messages.times(self.clamp_wd.engagements))
"far, control runs on.", messages.reason_code(self.clamp_wd.reason),
messages.times(self.clamp_wd.engagements))
_LOG.debug("Evidence: %s.", self.clamp_wd.reason)
_LOG.debug(
"SAFETY-03: silently clipping this is how a winding integrator "
"reached 14 768 W on this project before. The clamp makes every "
@@ -3931,7 +4122,9 @@ class Controller:
hint=messages.hint("peak_saturated"))
_LOG.error(
"Switch off large loads, the battery alone cannot keep this "
"15-minute period under the peak limit. %s.", g.reason)
"15-minute period under the peak limit: %s.",
messages.reason_code(g.reason))
_LOG.debug("Evidence: %s.", g.reason)
# A fixed notification_id, and a DIFFERENT one from every other alarm
# here - check_meter_frozen() gives the reasoning. A saturated peak guard
# is not a frozen meter and is not an out-of-range setpoint.
@@ -3988,7 +4181,8 @@ class Controller:
self.log_event(g.reason, hint=messages.hint("peak_reserve"))
_LOG.error(
"Switch off large loads, the peak guard may not draw the battery "
"lower. %s.", g.reason)
"lower: %s.", messages.reason_code(g.reason))
_LOG.debug("Evidence: %s.", g.reason)
# A fixed notification_id, and a DIFFERENT one from every other alarm
# here - check_meter_frozen() gives the reasoning. A battery at its
# energy floor is not a saturated inverter and is not a frozen meter,
@@ -4148,8 +4342,9 @@ class Controller:
hint=messages.hint("meter_frozen"))
_LOG.error(
"The meter shows the same value while the battery is asked for "
"full power, and control still follows it, so check the meter. "
"%s.", self.freeze_wd.reason)
"full power, and control still follows it, so check the meter: "
"%s.", messages.reason_code(self.freeze_wd.reason))
_LOG.debug("Evidence: %s.", self.freeze_wd.reason)
_LOG.debug(
"SAFETY-18: nothing else stops this. The meter still answers, so "
"its age is fresh, the firmware watchdog is fed and the arbiter "
+38
View File
@@ -311,6 +311,22 @@ def seconds(value) -> str:
return f"{n} second" if n == "1" else f"{n} seconds"
# One token each, like a code, so the line keeps its length and stays greppable.
NO_REASON_SAVED, NO_REASON_CODE = "REASON_NOT_SAVED", "REASON_WITHOUT_CODE"
_REASON_CODE = re.compile(r"\b[A-Z][A-Z0-9]*(?:_[A-Z0-9]+)+\b")
def reason_code(reason) -> str:
"""UX-11: the code in a safety reason (`STALE_READING`), for the one plain
WARNING or ERROR line that reports it. The reason with its figures goes on
a DEBUG line beside it and into the action log. Saved reasons have always
opened with their code, so an old state file reads the same way."""
if not reason:
return NO_REASON_SAVED
m = _REASON_CODE.search(str(reason))
return m.group(0) if m else NO_REASON_CODE
def times(n) -> str:
return "1 time" if int(n) == 1 else f"{int(n)} times"
@@ -786,6 +802,9 @@ WHY_WINNER = {
# failsafe winner. test_messages.py part 7 finds every one in the code.
"sign disagreement": "Safety stop, power went the wrong way",
"unsplit": "The power could not be split, all at 0 W",
# SAFETY-52: the loop's two words for a battery that gives nothing.
"battery refuses": "The battery refuses to give power",
"battery probe": "Testing if the battery gives power again",
}
WHY_LIMIT = {
"peak(quarter peak)": "the peak limit",
@@ -813,6 +832,11 @@ def why(winner, target_w, bound_by=None, *, contradiction=False) -> str:
return out
def why_missing(what, limit_s) -> str:
"""UX-11: past the hold, which reading is missing and what it does."""
return f"No usable {what} reading for over {seconds(limit_s)}: 0 W"
def why_waiting(missing_s) -> str:
"""A reading went missing a moment ago: control holds and waits."""
return f"A reading is missing for {seconds(missing_s)}, control waits"
@@ -831,6 +855,8 @@ HINTS = {
"stop_restored": "{unit}: an earlier safety stop is back, it stays at 0 W",
"battery_stuck": "{unit}: battery power reading stopped changing",
"battery_back": "{unit}: battery power reading is used again",
"battery_refuses": "The battery refuses to give power, the add-on asks 0 W",
"battery_gives": "The battery refusal ended, control asks for power again",
"bad_value": "The add-on made an invalid power value, inverters set to 0 W",
"write_blocked": "{unit}: a power request was blocked, it is set to 0 W",
"all_blocked": "A power request was blocked, inverters set to 0 W",
@@ -1073,6 +1099,18 @@ LABELS = {
"unit_sign_disagree_w": "Per-inverter wrong-direction threshold",
"slew_w": "Largest change per cycle",
"shadow_mode": "Shadow mode",
# UX-13: named by the settings page's warnings (validate.Note).
"integrator_max_w": "Catch-up limit",
"maintenance_discharge_w": "Draw-down rate",
"peak_cap_w": "Peak limit",
"peak_forecast_entity": "15-minute demand forecast entity",
"meter_entity": "Grid power entity",
"soc_entity": "Battery level entity",
"batt_entity": "Battery power entity",
"pv_entity": "Solar production entity",
"pv_entities": "Solar production entities, per inverter",
"p1_phase_import_entities": "Import entities per phase",
"p1_phase_export_entities": "Export entities per phase",
}
+6 -3
View File
@@ -288,7 +288,7 @@ async def problems_for(opts: dict, hass=None) -> list:
return problems
async def problems_and_ranges(opts: dict, hass=None):
async def problems_and_ranges(opts: dict, hass=None, notes=None):
"""`problems_for()`, plus WHICH setpoint entities did not report a range.
⚠️ THE SECOND HALF EXISTS SO THE PAGE CANNOT LOOK GREEN FOR A REASON THE
@@ -303,6 +303,8 @@ async def problems_and_ranges(opts: dict, hass=None):
has just typed a new `setpoint_entity` must be told about THAT entity, and
a route that asked the running controller instead would report on the old
one. That was the first shape of this and it disagreed with itself.
UX-13: a list passed as `notes` collects the validator's warnings too.
"""
flat = str(opts.get("setpoint_entity", "") or "").strip()
@@ -329,7 +331,7 @@ async def problems_and_ranges(opts: dict, hass=None):
# disagreement is itself the finding - so it is reported rather than
# swallowed. Returning `[]` here would turn a crash into a silent
# acceptance, which is worse than the 500 this replaced.
found = list(validate_startup_config(opts))
found = list(validate_startup_config(opts, notes=notes))
if not found:
found = [f"the configuration could not be composed ({type(exc).__name__}: "
f"{exc}), and the validator did not name a reason. This is a "
@@ -347,7 +349,8 @@ async def problems_and_ranges(opts: dict, hass=None):
if flat and unit.setpoint_entity.strip().lower() == flat.lower():
dev_min, dev_max = unit.dev_min, unit.dev_max
break
problems = list(validate_startup_config(opts, dev_min, dev_max))
problems = list(validate_startup_config(opts, dev_min, dev_max,
notes=notes))
problems += validate_unit_ranges(units, skip_entity=flat)
unread = [unit.setpoint_entity for unit in units
if unit.setpoint_entity and unit.dev_min is None
+38
View File
@@ -0,0 +1,38 @@
{
"groups": {
"meter": {"name": "Meter", "description": "Where the grid reading comes from."},
"inverters": {"name": "Inverters and batteries", "description": "The inverters the add-on controls, and your solar."},
"tariff": {"name": "Tariff and prices", "description": "What you pay and are paid per kWh."},
"safety": {"name": "Safety limits", "description": "The peak limit, starting and stopping, and the safety stops."},
"maintenance": {"name": "Maintenance", "description": "The monthly battery cycle and the log."},
"tuning": {"name": "Control tuning", "description": "For support only, because these were measured on real hardware."}
},
"parts": {
"meter.timing": {"name": "Timing"},
"inverters.solar": {"name": "Solar"},
"tariff.selling": {"name": "Charging and selling on price"},
"tariff.feed": {"name": "Price feed details"},
"safety.peak": {"name": "Peak limit"},
"safety.start": {"name": "Starting and stopping"},
"safety.stops": {"name": "Safety stops", "description": "Measured on real hardware, so leave them unchanged."},
"maintenance.support": {"name": "Support"}
},
"fields": {
"solar": {"name": "Solar inverters", "description": "Each solar inverter's power sensor, which the add-on records but does not use for control."},
"contract": {"name": "Your contract", "description": "How your supplier prices each kWh you take from the grid."},
"region": {"name": "Region", "description": "Fills in grid costs, levies and VAT for the year shown, but not yet for Wallonia or Brussels, so check your bill."},
"fallback": {"name": "Price when the feed is down", "description": "Used when the price source does not answer."},
"fixed_price": {"name": "Price per kWh, all in", "description": "Energy, supplier costs, grid costs, levies and VAT together."},
"day_price": {"name": "Day price, weekdays 07:00 to 22:00", "description": "All in, as on your bill."},
"night_price": {"name": "Night and weekend price", "description": "All in, as on your bill."}
},
"choices": {
"contract": {"none": "No prices", "fixed": "Fixed price", "daynight": "Day and night", "dynamic": "Dynamic, hourly", "custom": "Other time windows"},
"fallback": {"none": "None", "fixed": "One price", "daynight": "Day and night", "custom": "Other time windows"},
"region": {"flanders": "Flanders, Fluvius Antwerpen", "own": "I enter my own figure"}
},
"applies": {
"restart": {"name": "Applies after a restart"},
"now": {"name": "Applies right away"}
}
}
+295
View File
@@ -0,0 +1,295 @@
"""UX-13: the new page's layout, written once - screen, group, field.
UI code names option keys only here and in uimodel.py, which holds the
derivations this table lists (DECISIONS/UX-13-one-layout-table.md, amending
UX-02 §3). Everything else stays where UX-02 put it: ranges in config.yaml's
schema, rules in validate.py. test_uilayout.py fails CI when an option in
config.yaml has no place here.
A field's `key` is an option key, `inverters.<field>` for one inverter in the
list, or `ui.<name>` for a page-only control that uimodel.py turns into options.
The key is also its text key: label and help are translations/*.yaml's entry
for an option, and app/ui_text's `fields.<name>` for a `ui.` field.
"""
from dataclasses import dataclass
RESTART = "restart" # stored options apply after a restart (UX-02 §5)
NOW = "now" # runtime state (OPT-11's battery switches), none yet
# Controls are names, not string literals, so a key is never followed by a
# constant (test_defaults_pin.py reads `f("key", <constant>)` as a fallback).
CHOICE, ENTITY, ENTITY_LIST, TOGGLE, SEGMENTED, SLIDER = (
"choice", "entity", "entity_list", "toggle", "segmented", "slider")
NUMBER, TEXT, SELECT, LOCKED, INVERTER_LIST, SOLAR_LIST = (
"number", "text", "select", "locked", "inverter_list", "solar_list")
CONTROLS = (CHOICE, ENTITY, ENTITY_LIST, TOGGLE, SEGMENTED, SLIDER, NUMBER,
TEXT, SELECT, LOCKED, INVERTER_LIST, SOLAR_LIST)
# What an entity picker offers first. `power_w` is a power sensor the add-on
# reads as watts with no unit conversion, so validate.py warns on a kW sensor.
ENTITY_KINDS = ("power_w", "power", "energy", "pct", "number", "any")
SHOW_OPS = ("==", "!=", "in", ">", "<")
@dataclass(frozen=True)
class Field:
key: str
control: str
unit: str = ""
scale: int = 1 # shown = stored / scale (the peak limit in kW)
step: float = 0 # slider or number step, stored units; 0 = 1
kind: str = "" # entity picker filter, one of ENTITY_KINDS
show: tuple = () # ((name, op, value), ...), all must hold
applies: str = RESTART
simple: bool = False # also on Settings, Simple
wizard: int = 0 # setup wizard step 1-6, 0 = not in the wizard
@property
def text(self) -> str:
"""Where the label and help live: `translations` or `ui_text`."""
return "ui_text" if self.key.startswith("ui.") else "translations"
@dataclass(frozen=True)
class Part:
id: str # "" is the group's main part
fields: tuple
collapsed: bool = False
@dataclass(frozen=True)
class Group:
id: str
parts: tuple
support_only: bool = False # collapsed, with a "for support" warning
def _src(*values):
return (("meter_source", "in", values),)
_DYNAMIC = (("ui.contract", "==", "dynamic"),)
_MAINT = (("maintenance_enabled", "==", True),)
_ONE = (("inverter_count", "==", 1),)
_SEVERAL = (("inverter_count", ">", 1),)
_PHASES = (("meter_phases", ">", 1),)
# The per-inverter card. Its keys are `inverters.<field>` in config.yaml.
ROSTER_FIELDS = (
Field("inverters.name", TEXT, wizard=2),
Field("inverters.setpoint_entity", ENTITY, kind="number", wizard=2),
Field("inverters.max_w", SLIDER, "W", step=100, wizard=2),
Field("inverters.bms_soc_floor", SLIDER, "%", wizard=2),
Field("inverters.soc_entity", ENTITY, kind="pct", wizard=2),
Field("inverters.batt_entity", ENTITY, kind="power_w", wizard=2),
Field("inverters.batt_invert", TOGGLE, wizard=2),
Field("inverters.capacity_kwh", NUMBER, "kWh", step=0.1, wizard=2),
)
GROUPS = (
Group("meter", (
Part("", (
Field("meter_source", CHOICE, wizard=1),
Field("meter_entity", ENTITY, kind="power_w", show=_src("off"),
wizard=1),
Field("meter_invert", TOGGLE, show=_src("off"), wizard=1),
Field("p1_net_entity", ENTITY, kind="power_w",
show=_src("ha_signed"), wizard=1),
Field("p1_import_entity", ENTITY, kind="power_w",
show=_src("ha_dsmr"), wizard=1),
Field("p1_export_entity", ENTITY, kind="power_w",
show=_src("ha_dsmr"), wizard=1),
Field("p1_host", TEXT, show=_src("homewizard_local"), wizard=1),
Field("meter_mqtt_topic", TEXT, show=_src("mqtt_p1"), wizard=1),
Field("meter_phases", SEGMENTED, wizard=1),
Field("p1_phase_net_entities", ENTITY_LIST, kind="power_w",
show=_src("ha_signed") + _PHASES, wizard=1),
Field("p1_phase_import_entities", ENTITY_LIST, kind="power_w",
show=_src("ha_dsmr") + _PHASES, wizard=1),
Field("p1_phase_export_entities", ENTITY_LIST, kind="power_w",
show=_src("ha_dsmr") + _PHASES, wizard=1),
)),
Part("timing", (
Field("meter_max_age_s", SLIDER, "s", step=5),
Field("meter_poll_s", SLIDER, "s",
show=_src("homewizard_local")),
), collapsed=True),
)),
Group("inverters", (
Part("", (Field("inverters", INVERTER_LIST, wizard=2),)),
# pv.py reads each entity's own unit, so a kW sensor is fine here.
Part("solar", (Field("ui.solar", SOLAR_LIST, kind="power",
wizard=3),)),
)),
Group("tariff", (
Part("", (
Field("ui.contract", SEGMENTED, wizard=4),
Field("price_provider", SELECT, show=_DYNAMIC, wizard=4),
Field("price_formula", TEXT,
show=_DYNAMIC + (("price_provider", "==", "custom_formula"),),
wizard=4),
Field("price_csv_path", TEXT,
show=_DYNAMIC + (("price_provider", "==", "manual_csv"),),
wizard=4),
Field("ui.region", SELECT, wizard=4),
Field("price_taxes_eur_kwh", NUMBER, "€/kWh", step=0.00001,
wizard=4),
Field("price_markup_eur_kwh", NUMBER, "€/kWh", step=0.001,
show=_DYNAMIC, wizard=4),
Field("export_price_eur_kwh", NUMBER, "€/kWh", step=0.001,
wizard=4),
Field("price_export_formula", TEXT),
Field("ui.fallback", SEGMENTED, show=_DYNAMIC, wizard=4),
Field("ui.fixed_price", NUMBER, "€/kWh", step=0.01,
show=(("ui.fallback", "==", "fixed"),), wizard=4),
Field("ui.day_price", NUMBER, "€/kWh", step=0.01,
show=(("ui.fallback", "==", "daynight"),), wizard=4),
Field("ui.night_price", NUMBER, "€/kWh", step=0.01,
show=(("ui.fallback", "==", "daynight"),), wizard=4),
)),
Part("selling", (
# OPT-11: derived from the batteries' selling switches once battery
# modes exist (uimodel.arbitrage_from_batteries). A toggle until then.
Field("arbitrage_enabled", TOGGLE),
Field("cycle_cost_threshold_eur", NUMBER, "€/kWh", step=0.01),
Field("arbitrage_soc_floor", SLIDER, "%"),
Field("arbitrage_soc_ceiling", SLIDER, "%"),
)),
Part("feed", (
Field("price_feed_url", TEXT, show=_DYNAMIC),
Field("price_horizon_h", SLIDER, "h", show=_DYNAMIC),
Field("price_timeout_s", SLIDER, "s", show=_DYNAMIC),
Field("price_now_entity", ENTITY, kind="any"),
Field("price_avg_entity", ENTITY, kind="any"),
), collapsed=True),
)),
Group("safety", (
Part("peak", (
Field("peak_cap_w", SLIDER, "kW", scale=1000, step=100,
simple=True, wizard=5),
Field("peak_forecast_entity", ENTITY, kind="power_w", wizard=5),
Field("peak_soc_floor", LOCKED, "%"),
)),
Part("start", (
Field("shadow_mode", SEGMENTED, simple=True, wizard=6),
Field("auto_start", TOGGLE),
Field("estop_fitted", TOGGLE),
Field("stale_input_s", SLIDER, "s"),
Field("meter_freeze_s", SLIDER, "s", step=30,
show=_src("homewizard_local")),
)),
Part("stops", (
Field("sign_disagree_w", LOCKED, "W", step=10, show=_ONE),
Field("sign_disagree_s", LOCKED, "s", step=5, show=_ONE),
Field("unit_sign_disagree_w", LOCKED, "W", step=10,
show=_SEVERAL),
Field("unit_sign_disagree_s", LOCKED, "s", step=5,
show=_SEVERAL),
Field("site_sign_disagree_w", LOCKED, "W", step=10,
show=_SEVERAL),
Field("site_sign_disagree_s", LOCKED, "s", step=5,
show=_SEVERAL),
Field("circulation_w", LOCKED, "W", step=10, show=_SEVERAL),
Field("circulation_hold_s", LOCKED, "s", step=5, show=_SEVERAL),
Field("delivery_hold_s", LOCKED, "s", step=5, show=_SEVERAL),
), collapsed=True),
)),
Group("maintenance", (
Part("", (
Field("maintenance_enabled", TOGGLE),
Field("maintenance_interval_days", SLIDER, "days", show=_MAINT),
Field("maintenance_start_hour", SELECT, show=_MAINT),
Field("maintenance_discharge_w", SLIDER, "W", step=100,
show=_MAINT),
Field("maintenance_charge_w", SLIDER, "W", step=100,
show=_MAINT),
Field("maintenance_soc_floor", SLIDER, "%", show=_MAINT),
Field("maintenance_soc_target", SLIDER, "%", show=_MAINT),
Field("maintenance_hold_min", SLIDER, "min", step=5,
show=_MAINT),
)),
Part("support", (Field("log_level", SELECT),)),
)),
Group("tuning", (
Part("", (
Field("gain", LOCKED, step=0.05),
Field("slew_w", LOCKED, "W", step=50),
Field("deadband_w", LOCKED, "W"),
Field("target_grid_w", LOCKED, "W"),
Field("step_w", LOCKED, "W"),
Field("saturation_w", LOCKED, "W", step=10),
Field("saturation_cycles", LOCKED),
Field("integrator_max_w", LOCKED, "W", step=100),
Field("heartbeat_s", LOCKED, "s"),
Field("cycle_floor_s", LOCKED, "s"),
)),
), support_only=True),
)
# Option keys the page never shows. uimodel.py writes each from page fields.
DERIVED = {
"setpoint_entity": "inverters", # one inverter, stored flat
"soc_entity": "inverters",
"batt_entity": "inverters",
"batt_invert": "inverters",
"max_w": "inverters",
"bms_soc_floor": "inverters",
"pv_entity": "ui.solar", # one solar row, stored flat
"pv_entities": "ui.solar",
"pv_invert_entities": "ui.solar", # the rows' "reads negative" toggles
"static_profile": "ui.fallback", # built from the price fields
"price_taxes_profile": "ui.region", # a preset writes it, "own" keeps it
}
# Option keys the page never shows and never writes: passed through as stored.
HIDDEN: dict = {}
def fields():
"""Every field once, in page order, roster fields after `inverters`."""
for group in GROUPS:
for part in group.parts:
for field in part.fields:
yield group, part, field
if field.control == INVERTER_LIST:
for sub in ROSTER_FIELDS:
yield group, part, sub
def field(key: str) -> Field | None:
return next((f for _g, _p, f in fields() if f.key == key), None)
def visible(fld: Field, model: dict) -> bool:
"""Whether `fld` is shown for this page model (uimodel.options_to_ui)."""
for name, op, value in fld.show:
have = model.get(name)
if op == "==" and have != value:
return False
if op == "!=" and have == value:
return False
if op == "in" and have not in value:
return False
try:
if op == ">" and not float(have) > value:
return False
if op == "<" and not float(have) < value:
return False
except (TypeError, ValueError):
return False
return True
def range_of(key: str, schema_ui: list):
"""(min, max) from the Supervisor's schema (`info["schema"]`), or None.
Never typed here: config.yaml is the one place a range is written. A range
arrives as lengthMin/lengthMax (tools/supervisor_selfapi_probe.py)."""
path = key.split(".")
nodes = schema_ui or []
for step in path[:-1]:
parent = next((n for n in nodes if n.get("name") == step), None)
nodes = (parent or {}).get("schema") or []
node = next((n for n in nodes if n.get("name") == path[-1]), None)
if not node or "lengthMin" not in node or "lengthMax" not in node:
return None
return node["lengthMin"], node["lengthMax"]
+331
View File
@@ -0,0 +1,331 @@
"""UX-13: stored options <-> the page model, for the keys the page derives.
`options_to_ui()` turns the stored blob into what the page edits: always a list
of inverter cards, solar rows with a "reads negative" toggle, a contract and
simple prices instead of `static_profile` JSON, and a region preset instead of
the levies figure. `ui_to_options()` turns it back, so the validator and the
Supervisor always see the real blob.
The rule that makes the round trip exact: the model carries the stored values
of the derived keys (`keep`). A derivation whose page fields still read what
`keep` decodes to writes `keep` back untouched, and only an edited one is
re-encoded. So a blob the page cannot express (a `static_profile` with odd
windows, a malformed roster) survives a save of some other field unchanged.
See DECISIONS/UX-13-one-layout-table.md.
"""
import copy
import json
from .price import FLEMISH_TAXES_COMPONENTS_EUR_KWH
from .static_tariff import ProfileInvalid, parse_static_profile
__all__ = ["options_to_ui", "ui_to_options", "REGION_PRESETS",
"arbitrage_from_batteries", "DeriveError"]
class DeriveError(ValueError):
"""The page model asks for something no options blob can say."""
# --------------------------------------------------------------------------- #
# Region presets for "Grid costs, levies and VAT". Year-stamped, updated each
# January (owner, 2026-09-27). Only presets with a sourced figure are listed:
# Flanders is app/price.py's Fluvius Antwerpen sum (TARIFF-18: Eneco
# residential card, Flanders, September 2026, VAT included). Wallonia and
# Brussels have a day and a night band (config.yaml) and join with sourced
# figures; until then those sites choose "own".
# --------------------------------------------------------------------------- #
REGION_PRESETS = {
"flanders": {
"year": 2026,
"taxes_eur_kwh": round(sum(v for _n, v in
FLEMISH_TAXES_COMPONENTS_EUR_KWH), 5),
"taxes_profile": "",
},
}
OWN = "own"
_ROSTER_FLAT = ("setpoint_entity", "soc_entity", "batt_entity", "batt_invert",
"max_w", "bms_soc_floor")
_TOL = 1e-9
def _blank(v) -> bool:
return v is None or (isinstance(v, str) and not v.strip())
def _num(v):
try:
return None if _blank(v) or isinstance(v, bool) else float(v)
except (TypeError, ValueError):
return None
# --- 1. one inverter (flat keys) or the `inverters` list -------------------- #
def _roster_decode(o):
entries = o.get("inverters")
if entries is None or entries == "" or entries == []:
card = {k: o.get(k) for k in _ROSTER_FLAT}
card.update(name="", capacity_kwh=None)
return {"inverter_shape": "flat", "inverters": [card]}
if isinstance(entries, list) and all(isinstance(e, dict) for e in entries):
return {"inverter_shape": "list",
"inverters": [dict(e) for e in entries]}
# Not something a card can show: edited in the Configuration tab only.
return {"inverter_shape": "raw", "inverters": None}
def _roster_encode(m, keep):
out = {}
shape, cards = m.get("inverter_shape"), m.get("inverters")
if shape == "raw":
raise DeriveError("the inverter list is edited in the Configuration tab")
if not cards:
raise DeriveError("at least one inverter is needed")
if shape == "flat" and len(cards) == 1:
card = cards[0]
if not _blank(card.get("name")) or not _blank(card.get("capacity_kwh")):
raise DeriveError("one inverter stored flat has no name or capacity")
for k in _ROSTER_FLAT:
if card.get(k) is not None or k in keep:
out[k] = card.get(k)
out["inverters"] = []
return out
out["inverters"] = [{k: v for k, v in c.items() if v is not None}
for c in cards]
# The flat keys beside a list are not read: they stay as stored.
out.update({k: copy.deepcopy(keep[k]) for k in _ROSTER_FLAT if k in keep})
if shape == "flat":
# CFG-04 rule 9e: a flat power request entity beside a list is refused.
out["setpoint_entity"] = ""
return out
# --- 2. solar rows: pv_entity / pv_entities / pv_invert_entities ------------ #
def _strs(v):
return [str(x).strip() for x in (v if isinstance(v, list) else [])
if not _blank(x)]
def _solar_rows(o):
listed = _strs(o.get("pv_entities"))
if listed:
return listed, True
one = "" if _blank(o.get("pv_entity")) else str(o.get("pv_entity")).strip()
return ([one] if one else []), False
def _solar_decode(o):
rows, _listed = _solar_rows(o)
flipped = set(_strs(o.get("pv_invert_entities")))
return {"ui.solar": [{"entity": e, "reversed": e in flipped}
for e in rows]}
def _solar_encode(m, keep):
out = {}
rows = [r for r in (m.get("ui.solar") or [])
if not _blank(r.get("entity"))]
entities = [str(r["entity"]).strip() for r in rows]
old_rows, was_list = _solar_rows(keep)
if len(entities) <= 1 and not was_list:
out["pv_entity"] = entities[0] if entities else ""
if "pv_entities" in keep:
out["pv_entities"] = []
else:
out["pv_entities"] = entities
if "pv_entity" in keep:
out["pv_entity"] = "" # TEL-12: the list replaces it
# Flips of entities that were never a row stay as stored (pv.stray_inverts
# reports them). Flips of removed rows go with the row.
extras = [x for x in _strs(keep.get("pv_invert_entities"))
if x not in old_rows and x not in entities]
flips = [e for e, r in zip(entities, rows) if r.get("reversed")] + extras
if flips or "pv_invert_entities" in keep:
out["pv_invert_entities"] = flips
return out
# --- 3. contract and static_profile ----------------------------------------- #
def _fixed_json(price) -> str:
return json.dumps({"periods": [
{"name": "all", "from": "00:00", "to": "24:00", "days": "mon-sun",
"eur_per_kwh": price}]})
def _daynight_json(day, night) -> str:
return json.dumps({"periods": [
{"name": "day", "from": "07:00", "to": "22:00", "days": "mon-fri",
"eur_per_kwh": day},
{"name": "night", "from": "22:00", "to": "07:00", "days": "mon-fri",
"eur_per_kwh": night},
{"name": "night", "from": "00:00", "to": "24:00", "days": "sat,sun",
"eur_per_kwh": night}]})
def _shape(text):
"""The periods of a profile without their names, for comparing, or None."""
try:
prof = parse_static_profile(text)
except ProfileInvalid:
return None
if prof is None:
return ()
return tuple(sorted((p.start_min, p.end_min, tuple(sorted(p.days)),
p.eur_per_kwh) for p in prof.periods))
def _profile_decode(raw):
"""("none"|"fixed"|"daynight"|"custom", fixed, day, night)."""
if isinstance(raw, str) and _blank(raw):
return "none", None, None, None
if not isinstance(raw, str):
return "custom", None, None, None
got = _shape(raw)
if not got:
return ("none" if got == () else "custom"), None, None, None
if len(got) == 1 and got == _shape(_fixed_json(got[0][3])):
return "fixed", got[0][3], None, None
day = next((p[3] for p in got if p[:2] == (420, 1320)), None)
night = next((p[3] for p in got if p[:2] == (1320, 420)), None)
if (day is not None and night is not None
and got == _shape(_daynight_json(day, night))):
return "daynight", None, day, night
return "custom", None, None, None
def _tariff_decode(o):
kind, fixed, day, night = _profile_decode(o.get("static_profile", ""))
provider = o.get("price_provider")
dynamic = not _blank(provider) and provider != "off"
return {"ui.contract": "dynamic" if dynamic else kind,
"price_provider": provider, "ui.fallback": kind,
"ui.fixed_price": fixed, "ui.day_price": day,
"ui.night_price": night}
def _tariff_encode(m, keep):
out = {}
contract = m.get("ui.contract")
if contract == "dynamic":
if _blank(m.get("price_provider")) or m.get("price_provider") == "off":
raise DeriveError("a dynamic contract needs a price source")
out["price_provider"] = m["price_provider"]
kind = m.get("ui.fallback")
else:
out["price_provider"] = "off"
kind = contract
if kind == "none":
out["static_profile"] = ""
elif kind == "fixed":
out["static_profile"] = _fixed_json(_price_of(m, "ui.fixed_price"))
elif kind == "daynight":
out["static_profile"] = _daynight_json(_price_of(m, "ui.day_price"),
_price_of(m, "ui.night_price"))
elif kind == "custom":
if "static_profile" not in keep:
raise DeriveError("odd tariff windows are edited in the "
"Configuration tab")
out["static_profile"] = keep["static_profile"]
else:
raise DeriveError(f"unknown contract {kind!r}")
return out
def _price_of(m, name):
value = _num(m.get(name))
if value is None:
raise DeriveError(f"{name} needs a price")
return value
# --- 4. region preset -> price_taxes_eur_kwh / price_taxes_profile ---------- #
def _region_decode(o):
taxes, profile = o.get("price_taxes_eur_kwh"), o.get("price_taxes_profile", "")
region = OWN
for rid, p in REGION_PRESETS.items():
same = _num(taxes) is not None and abs(_num(taxes) - p["taxes_eur_kwh"]) < _TOL
if same and str(profile or "").strip() == p["taxes_profile"]:
region = rid
return {"ui.region": region, "price_taxes_eur_kwh": taxes}
def _region_encode(m, keep):
region = m.get("ui.region")
if region == OWN:
out = {"price_taxes_eur_kwh": m.get("price_taxes_eur_kwh")}
if "price_taxes_profile" in keep: # "own" keeps the stored table
out["price_taxes_profile"] = keep["price_taxes_profile"]
return out
if region not in REGION_PRESETS:
raise DeriveError(f"unknown region {region!r}")
p = REGION_PRESETS[region]
out = {"price_taxes_eur_kwh": p["taxes_eur_kwh"]}
if p["taxes_profile"] or "price_taxes_profile" in keep:
out["price_taxes_profile"] = p["taxes_profile"]
return out
# --- 5. arbitrage_enabled: the OPT-11 hook ---------------------------------- #
def arbitrage_from_batteries(m):
"""OPT-11 hook. With battery modes on, `arbitrage_enabled` is true when any
battery may sell. Battery modes are not built yet, so this returns None and
the toggle is stored as the page has it: no behaviour change."""
return None
def _arbitrage_decode(o):
return {"arbitrage_enabled": o.get("arbitrage_enabled")}
def _arbitrage_encode(m, keep):
derived = arbitrage_from_batteries(m)
value = m.get("arbitrage_enabled") if derived is None else derived
return {} if value is None and "arbitrage_enabled" not in keep \
else {"arbitrage_enabled": value}
# (option keys it writes, decode, encode). Each is independent of the others.
DERIVATIONS = (
(("inverters",) + _ROSTER_FLAT, _roster_decode, _roster_encode),
(("pv_entity", "pv_entities", "pv_invert_entities"), _solar_decode,
_solar_encode),
(("price_provider", "static_profile"), _tariff_decode, _tariff_encode),
(("price_taxes_eur_kwh", "price_taxes_profile"), _region_decode,
_region_encode),
(("arbitrage_enabled",), _arbitrage_decode, _arbitrage_encode),
)
_OWNED = {k for keys, _d, _e in DERIVATIONS for k in keys}
_MODEL_ONLY = ("keep", "inverter_shape", "inverter_count", "region_year")
def options_to_ui(options: dict) -> dict:
"""The page model for a stored blob. Pure: reads nothing else."""
model = {k: copy.deepcopy(v) for k, v in options.items()
if k not in _OWNED}
for _keys, decode, _encode in DERIVATIONS:
model.update(decode(options))
model["keep"] = {k: copy.deepcopy(options[k]) for k in _OWNED
if k in options}
cards = model.get("inverters")
model["inverter_count"] = len(cards) if isinstance(cards, list) else None
preset = REGION_PRESETS.get(model["ui.region"])
model["region_year"] = preset["year"] if preset else None
return model
def ui_to_options(model: dict) -> dict:
"""The options blob for a page model. Raises DeriveError on a model no blob
can express, so the page says so instead of saving something else."""
keep = model.get("keep") or {}
out = {k: copy.deepcopy(v) for k, v in model.items()
if k not in _MODEL_ONLY and k not in _OWNED
and not k.startswith("ui.")}
for keys, decode, encode in DERIVATIONS:
was = decode(keep)
if all(model.get(name) == value for name, value in was.items()):
out.update({k: copy.deepcopy(keep[k]) for k in keys if k in keep})
else:
out.update(encode(model, keep))
return out
+130 -5
View File
@@ -321,8 +321,9 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
"""
import logging
from typing import NamedTuple
from . import messages
from . import messages, pv
from .arbitrage import enabled as arbitrage_on
from .control import SLEW_RAIL_FRAC, LOOP_TICK_S, PLANT_SETTLE_S
from .custom_formula import (
@@ -330,7 +331,8 @@ from .custom_formula import (
parse_export_formula, parse_price_formula, stale_card)
from .inverter import roster_entries
from .maintenance import MAINT_OPTION_DEFAULTS
from .p1 import is_enabled, validate_meter_options
from .p1 import (
SOURCE_HA, SOURCE_HA_SIGNED, is_enabled, validate_meter_options)
from .peakguard import PEAK_OPTION_DEFAULTS
from .price import (
PRICE_OPTION_DEFAULTS, PROVIDERS, RETIRED_PROVIDERS,
@@ -367,6 +369,22 @@ class _WarnOnce(logging.Filter):
WARN_ONCE = _WarnOnce()
_LOG.addFilter(WARN_ONCE)
class Note(NamedTuple):
"""UX-13: a warning or info for the settings page. Never a refusal: the
add-on starts. `keys` are the options it is about, so the page can show it
beside them."""
tier: str # "warn" or "info"
keys: tuple
text: str
def _advise(notes, tier: str, keys, text: str) -> None:
"""Add a Note when the caller collects them (the settings page)."""
if notes is not None:
notes.append(Note(tier, tuple(keys), text))
# ⚠️ A MIRROR OF A FIRMWARE CONSTANT, AND IT CANNOT BE IMPORTED. The firmware
# threshold is a compile-time YAML substitution baked into the ESP32 image
# (`max_age_s: "30"`, master/goodwe-master-stage4-failsafe.yaml), so nothing at
@@ -789,7 +807,8 @@ class ConfigRefused(Exception):
super().__init__(problems[0] if problems else "configuration refused")
def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]:
def validate_startup_config(opts: dict, dev_min=None, dev_max=None,
notes: list | None = None) -> list[str]:
"""Return the list of reasons this configuration must not be started.
Empty list means go. `dev_min`/`dev_max` are the setpoint device's own
@@ -799,6 +818,9 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
Pure and side-effect free apart from two warnings, so it can be called from
a test or from sim/inject.py without a Home Assistant anywhere near it.
UX-13: pass a list as `notes` to also get each logged warning as a `Note`
for the settings page. The refusals returned do not depend on it.
"""
problems: list[str] = []
@@ -1127,7 +1149,7 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
f"site. Set it to 0 or to at most {bound:.0f} W.")
# --- 7. two price sources on one site ------------------------------------
problems.extend(_price_problems(opts))
problems.extend(_price_problems(opts, notes))
# --- 8. an EMS energy floor the BMS does not already enforce -------------
# ⚠️ THE FALLBACKS ARE peakguard.PEAK_OPTION_DEFAULTS, NOT LITERALS, and
@@ -1173,6 +1195,9 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
"integrator_max_w %.0f W is above max_w %.0f W. This is allowed, "
"but it only adds overshoot, so 0 is recommended.",
integ_w, max_w)
_advise(notes, "warn", ("integrator_max_w",),
f"{S('integrator_max_w')} is above {S('max_w')}, which only "
"adds overshoot, so set it to 0.")
# ⚠️ THE SIBLING OF RULE 6, AND NOT THE SAME CASE - see the docstring. The
# drain phase OWNS the actuator (`Claim.set` at P_MAINTENANCE), and a SET is
@@ -1197,6 +1222,10 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
"maintenance_discharge_w %.0f W is above max_w%s %.0f W, so "
"draining runs at %.0f W. Lower it to %.0f W or raise max_w.",
disch_w, maint_where, maint_cap, maint_cap, maint_cap)
_advise(notes, "warn", ("maintenance_discharge_w",),
f"{S('maintenance_discharge_w')} is above "
f"{S('max_w', maint_where)}, so the battery empties at "
f"{messages.watts(maint_cap)} and the cycle takes longer.")
_LOG.debug(
"Not refused: the drain phase sets the setpoint, the arbiter "
"clamps it to %.0f W and names the clamp, and the drain phase has "
@@ -1205,7 +1234,7 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
return problems
def _price_problems(opts: dict) -> list[str]:
def _price_problems(opts: dict, notes: list | None = None) -> list[str]:
"""Rule 7 (TARIFF-02): the price configuration, refused where it is untrue.
⚠️ NOTE WHAT IS *NOT* HERE. `price_provider: "off"` is not refused and never
@@ -1423,6 +1452,9 @@ def _price_problems(opts: dict) -> list[str]:
"%s has negative levies %s EUR/kWh, which are subtracted from "
"the price. This is allowed, but it is usually a sign error.",
TAXES_PROFILE_OPTION, negative)
_advise(notes, "warn", (TAXES_PROFILE_OPTION,),
f"{S(TAXES_PROFILE_OPTION)} has negative figures, which "
"lower the price, and that is usually a sign error.")
# ⚠️ TARIFF-15: THE FORMULA, GRADED AGAINST THE OPERATOR'S OWN CARD, AT
# STARTUP RATHER THAN AT 03:00.
@@ -1478,6 +1510,10 @@ def _price_problems(opts: dict) -> list[str]:
"price_formula is filled in, but price_provider is %r, so the "
"formula is not used. Set price_provider to 'custom_formula' "
"or clear price_formula.", pid)
_advise(notes, "warn", ("price_formula", "price_provider"),
f"{S('price_formula')} is not used, because "
f"{S('price_provider')} is not 'custom_formula', so clear "
"it or choose that source.")
if spec is not None and pid == "custom_formula":
taxes = _number(opts, "price_taxes_eur_kwh",
PRICE_OPTION_DEFAULTS["price_taxes_eur_kwh"])
@@ -1491,6 +1527,8 @@ def _price_problems(opts: dict) -> list[str]:
# exactly right and a site refused over one is a site that
# cannot start.
_LOG.warning("%s", aged)
_advise(notes, "warn", ("price_formula",),
_card_note("price_formula", spec))
# ⚠️ TARIFF-16: THE INJECTION LEG, REFUSED AT STARTUP ON THE SAME RULE.
#
@@ -1571,6 +1609,9 @@ def _price_problems(opts: dict) -> list[str]:
"%.4g, offset %+.5f EUR/kWh).",
EXPORT_FORMULA_OPTION, xspec.passthrough,
xspec.offset_eur_kwh)
_advise(notes, "info", (EXPORT_FORMULA_OPTION,),
f"{S(EXPORT_FORMULA_OPTION)} has no card block, so "
"only the shape of its numbers is checked.")
_LOG.debug(
"Accepted because some suppliers (Eneco) print the "
"injection formula with no price beside it. If your card "
@@ -1582,6 +1623,8 @@ def _price_problems(opts: dict) -> list[str]:
xaged = stale_card(xspec)
if xaged:
_LOG.warning("%s", xaged)
_advise(notes, "warn", (EXPORT_FORMULA_OPTION,),
_card_note(EXPORT_FORMULA_OPTION, xspec))
# ⚠️ A WARNING, NOT A REFUSAL, AND THE ASYMMETRY IS DELIBERATE. §11.4 says a
# site with no price data falls back to the static profile; a dynamic site
@@ -1593,6 +1636,9 @@ def _price_problems(opts: dict) -> list[str]:
"price_provider is %r but static_profile is empty, so a price "
"feed outage leaves no tariff at all. Fill in static_profile as a "
"fallback.", pid)
_advise(notes, "warn", ("static_profile",),
f"{S('static_profile')} is empty, so the site has no tariff "
"at all while the price feed is down.")
# ⚠️ OPT-04. THE THREE WAYS `arbitrage_enabled: true` CAN BE A LIE, refused
# rather than logged, because a strategy that is armed in the UI and cannot
@@ -1644,6 +1690,85 @@ def _price_problems(opts: dict) -> list[str]:
return problems
def _card_note(option: str, spec) -> str:
return (f"{S(option)} uses a tariff card dated {spec.card_month}, so copy "
"the new figures if your contract changed.")
# UX-13: entity options whose number the add-on takes as watts, with no unit
# conversion. pv.py converts each solar entity's own unit, so those are not here.
WATT_ENTITY_KEYS = (
"meter_entity", "p1_net_entity", "p1_import_entity", "p1_export_entity",
"p1_phase_net_entities", "p1_phase_import_entities",
"p1_phase_export_entities", "batt_entity", "peak_forecast_entity")
def _entities_read(opts: dict) -> list[tuple[str, str, str]]:
"""(key, inverter name or "", entity id) for each entity the add-on reads
with these options. Keys the chosen meter source or roster shape ignores
are left out, so a stale default is not reported."""
out = []
def add(key, value, where=""):
for e in (value if isinstance(value, list) else [value]):
if isinstance(e, str) and e.strip():
out.append((key, where, e.strip()))
source = str(opts.get("meter_source") or "off").strip()
by_source = {"off": ("meter_entity",),
SOURCE_HA_SIGNED: ("p1_net_entity", "p1_phase_net_entities"),
SOURCE_HA: ("p1_import_entity", "p1_export_entity",
"p1_phase_import_entities",
"p1_phase_export_entities")}
for key in by_source.get(source, ()):
add(key, opts.get(key))
entries = roster_entries(opts)
if not entries:
for key in ("setpoint_entity", "soc_entity", "batt_entity"):
add(key, opts.get(key))
for i, entry in enumerate(entries):
if isinstance(entry, dict):
where = _unit_label(opts, i).strip().strip("()")
for key in ("setpoint_entity", "soc_entity", "batt_entity"):
add(key, entry.get(key), where)
solar = [e for e in (opts.get("pv_entities") or []) if str(e or "").strip()]
add("pv_entities" if solar else "pv_entity", list(pv.entities(opts)))
for key in ("peak_forecast_entity", "price_now_entity", "price_avg_entity"):
add(key, opts.get(key))
return out
def config_notes(opts: dict, *, entities: dict | None = None,
month_peak_w=None) -> list[Note]:
"""UX-13: warnings that need live data, for the settings page. Never a
refusal, and nothing here changes what `validate_startup_config()` says.
`entities` is Home Assistant's entity list by id (app/haentities.py), or
None when it could not be read, in which case those checks are skipped.
`month_peak_w` is this month's peak so far, or None.
"""
notes: list[Note] = []
if entities is not None:
for key, where, entity in _entities_read(opts):
row = entities.get(entity)
if row is None:
_advise(notes, "warn", (key,),
f"Home Assistant has no entity {entity}, which "
f"{S(key, where)} names.")
continue
unit = str(row.get("unit") or "")
if key in WATT_ENTITY_KEYS and unit in pv.WATTS_PER and unit != "W":
_advise(notes, "warn", (key,),
f"{entity} reads in {unit}, but {S(key, where)} is "
"taken as watts, so pick a sensor in W.")
cap = _number(opts, "peak_cap_w", None)
if month_peak_w is not None and cap is not None and cap < month_peak_w:
_advise(notes, "warn", ("peak_cap_w",),
f"This month's peak is already {messages.watts(month_peak_w)}, "
f"so a lower {S('peak_cap_w')} saves nothing until next month.")
return notes
def _number(opts: dict, key, default):
raw = opts.get(key, default)
if raw is None or raw == "":
+4 -5
View File
@@ -670,11 +670,10 @@ class SignWatchdog:
# ⚠️ `self.against` IS THE ONLY THING SAFETY-30 CHANGED IN THIS STRING,
# and it defaults to the wording that shipped - "a meter reading" - so a
# one-inverter install's `reason` is byte-identical to what an operator
# (and test_watchdog.py) has always read. A per-unit instance names what
# it actually compared instead, because "commanded +1500 W against a
# meter reading -1500 W" would be a false statement about which
# instrument produced the evidence, on the one line somebody woken by
# this alarm reads first.
# has always read (test_watchdog.py pins its meaning). A per-unit
# instance names what it actually compared instead, because "commanded
# +1500 W against a meter reading -1500 W" would be a false statement
# about which instrument produced the evidence.
self.reason = (
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against "
f"{self.against} {against_w:+.0f} W for {held:.0f} s continuously "
+19 -3
View File
@@ -24,7 +24,8 @@ routes below read `GET /addons/self/info`, run the SHIPPED validator, write
mode or reaches `controller.handle_action()`. The set of things an operator can
do to the inverter through this panel is exactly what `/action` offered before
this card - test_selfconfig.py part 7 asserts that by listing the routes and the
actions and comparing them with the shipped set.
actions and comparing them with the shipped set. UX-13's `ha/entities` is a GET
of Home Assistant's entity list (app/haentities.py) and writes nothing.
"""
import logging
@@ -32,6 +33,8 @@ import logging
from aiohttp import web
from . import messages, selfconfig
from .haentities import EntityCache
from .validate import config_notes
from .config_page import CONFIG_PAGE
from .configui import changed_keys, field_model, problems_by_field
@@ -140,6 +143,7 @@ def build_app(controller, selfcfg=None) -> web.Application:
if selfcfg is None:
selfcfg = selfconfig.SelfConfig(controller.hass.session,
controller.hass.token)
entities = EntityCache(controller.hass)
async def index(_request):
return web.Response(text=PAGE, content_type="text/html")
@@ -216,11 +220,16 @@ def build_app(controller, selfcfg=None) -> web.Application:
be a second opinion about a rule it does not own.
"""
_body, options = await _proposed(request)
notes = []
problems, unread = await selfconfig.problems_and_ranges(
options, controller.hass)
options, controller.hass, notes=notes)
by_key, unanchored = problems_by_field(problems, _keys_of(options))
# UX-13: warnings and info beside the refusals. Never block a save.
# The entity checks use the picker's cached list and never wait on HA.
notes += config_notes(options, entities=entities.peek())
payload = {"problems": problems, "by_key": by_key,
"unanchored": unanchored}
"unanchored": unanchored,
"notes": [n._asdict() for n in notes]}
if unread:
payload["device_note"] = DEVICE_NOTE % ", ".join(sorted(set(unread)))
return web.json_response(payload)
@@ -290,6 +299,12 @@ def build_app(controller, selfcfg=None) -> web.Application:
hint=messages.hint("restart_requested"))
return web.json_response({"ok": True})
async def ha_entities(request):
"""UX-13: Home Assistant's entities for the picker. A read only, and
never an error: when Home Assistant is down the list says so."""
kind = str(request.query.get("kind", "") or "")[:16]
return web.json_response(await entities.payload(kind))
app = web.Application()
app.add_routes([
web.get("/", index),
@@ -300,6 +315,7 @@ def build_app(controller, selfcfg=None) -> web.Application:
web.post("/config/validate", config_validate),
web.post("/config/save", config_save),
web.post("/config/restart", config_restart),
web.get("/ha/entities", ha_entities),
])
return app
@@ -0,0 +1,73 @@
{
"arbitrage_enabled": true,
"arbitrage_soc_ceiling": 95,
"arbitrage_soc_floor": 20,
"auto_start": false,
"batt_entity": "sensor.test23_battery_power",
"batt_invert": false,
"bms_soc_floor": 10,
"circulation_hold_s": 75,
"circulation_w": 700,
"cycle_cost_threshold_eur": 0.1,
"cycle_floor_s": 15,
"deadband_w": 15,
"delivery_hold_s": 185,
"estop_fitted": false,
"export_price_eur_kwh": 0.04,
"gain": 0.6,
"heartbeat_s": 10,
"integrator_max_w": 0,
"inverters": [],
"log_level": "info",
"maintenance_charge_w": 2000,
"maintenance_discharge_w": 2000,
"maintenance_enabled": false,
"maintenance_hold_min": 120,
"maintenance_interval_days": 28,
"maintenance_soc_floor": 11,
"maintenance_soc_target": 99,
"maintenance_start_hour": 10,
"max_w": 2000,
"meter_entity": "sensor.p1_meter_active_power",
"meter_freeze_s": 300,
"meter_invert": false,
"meter_max_age_s": 30,
"meter_mqtt_topic": "",
"meter_phases": 1,
"meter_poll_s": 5,
"meter_source": "ha_signed",
"p1_export_entity": "",
"p1_host": "",
"p1_import_entity": "",
"p1_net_entity": "sensor.test23_p1_meter_active_power",
"p1_phase_export_entities": [],
"p1_phase_import_entities": [],
"p1_phase_net_entities": [],
"peak_cap_w": 3500,
"peak_forecast_entity": "",
"peak_soc_floor": 20,
"price_avg_entity": "",
"price_csv_path": "/share/goodwe_prices.csv",
"price_feed_url": "https://api.energy-charts.info/price?bzn=BE",
"price_horizon_h": 48,
"price_markup_eur_kwh": 0.03,
"price_now_entity": "",
"price_provider": "generic_dayahead",
"price_taxes_eur_kwh": 0.06,
"price_timeout_s": 10,
"saturation_cycles": 3,
"saturation_w": 500,
"setpoint_entity": "number.test23_setpoint_w",
"sign_disagree_s": 180,
"sign_disagree_w": 300,
"site_sign_disagree_s": 325,
"site_sign_disagree_w": 300,
"slew_w": 0,
"soc_entity": "sensor.test23_soc",
"stale_input_s": 15,
"static_profile": "",
"step_w": 10,
"target_grid_w": -10,
"unit_sign_disagree_s": 85,
"unit_sign_disagree_w": 250
}
@@ -0,0 +1,73 @@
{
"arbitrage_enabled": false,
"arbitrage_soc_ceiling": 95,
"arbitrage_soc_floor": 20,
"auto_start": false,
"batt_entity": "",
"batt_invert": false,
"bms_soc_floor": 10,
"circulation_hold_s": 75,
"circulation_w": 700,
"cycle_cost_threshold_eur": 0.1,
"cycle_floor_s": 15,
"deadband_w": 15,
"delivery_hold_s": 185,
"estop_fitted": false,
"export_price_eur_kwh": 0.04,
"gain": 0.6,
"heartbeat_s": 10,
"integrator_max_w": 0,
"inverters": [],
"log_level": "info",
"maintenance_charge_w": 2000,
"maintenance_discharge_w": 2000,
"maintenance_enabled": false,
"maintenance_hold_min": 120,
"maintenance_interval_days": 28,
"maintenance_soc_floor": 11,
"maintenance_soc_target": 99,
"maintenance_start_hour": 10,
"max_w": 2000,
"meter_entity": "sensor.p1_meter_active_power",
"meter_freeze_s": 300,
"meter_invert": false,
"meter_max_age_s": 30,
"meter_mqtt_topic": "",
"meter_phases": 1,
"meter_poll_s": 5,
"meter_source": "off",
"p1_export_entity": "",
"p1_host": "",
"p1_import_entity": "",
"p1_net_entity": "",
"p1_phase_export_entities": [],
"p1_phase_import_entities": [],
"p1_phase_net_entities": [],
"peak_cap_w": 3500,
"peak_forecast_entity": "",
"peak_soc_floor": 20,
"price_avg_entity": "",
"price_csv_path": "/share/goodwe_prices.csv",
"price_feed_url": "",
"price_horizon_h": 48,
"price_markup_eur_kwh": 0.03,
"price_now_entity": "",
"price_provider": "off",
"price_taxes_eur_kwh": 0.06,
"price_timeout_s": 10,
"saturation_cycles": 3,
"saturation_w": 500,
"setpoint_entity": "",
"sign_disagree_s": 180,
"sign_disagree_w": 300,
"site_sign_disagree_s": 325,
"site_sign_disagree_w": 300,
"slew_w": 0,
"soc_entity": "",
"stale_input_s": 15,
"static_profile": "",
"step_w": 10,
"target_grid_w": -10,
"unit_sign_disagree_s": 85,
"unit_sign_disagree_w": 250
}
@@ -0,0 +1,98 @@
{
"arbitrage_enabled": false,
"arbitrage_soc_ceiling": 95,
"arbitrage_soc_floor": 20,
"auto_start": false,
"batt_entity": "sensor.test23_battery_power",
"batt_invert": false,
"bms_soc_floor": 10,
"circulation_hold_s": 75,
"circulation_w": 700,
"cycle_cost_threshold_eur": 0.1,
"cycle_floor_s": 15,
"deadband_w": 15,
"delivery_hold_s": 185,
"estop_fitted": false,
"export_price_eur_kwh": 0.04,
"gain": 0.6,
"heartbeat_s": 10,
"integrator_max_w": 0,
"inverters": [
{
"batt_entity": "sensor.goodwe_a_battery_power",
"bms_soc_floor": 10,
"capacity_kwh": 15.36,
"max_w": 5000,
"name": "inverter-a",
"setpoint_entity": "number.goodwe_a_setpoint_w",
"soc_entity": "sensor.goodwe_a_soc"
},
{
"batt_entity": "sensor.goodwe_b_battery_power",
"bms_soc_floor": 10,
"capacity_kwh": 20.48,
"max_w": 4600,
"name": "inverter-b",
"setpoint_entity": "number.goodwe_b_setpoint_w",
"soc_entity": "sensor.goodwe_b_soc"
}
],
"log_level": "info",
"maintenance_charge_w": 2000,
"maintenance_discharge_w": 2000,
"maintenance_enabled": false,
"maintenance_hold_min": 120,
"maintenance_interval_days": 28,
"maintenance_soc_floor": 11,
"maintenance_soc_target": 99,
"maintenance_start_hour": 10,
"max_w": 2000,
"meter_entity": "sensor.p1_meter_active_power",
"meter_freeze_s": 300,
"meter_invert": false,
"meter_max_age_s": 30,
"meter_mqtt_topic": "",
"meter_phases": 1,
"meter_poll_s": 5,
"meter_source": "ha_signed",
"p1_export_entity": "",
"p1_host": "",
"p1_import_entity": "",
"p1_net_entity": "sensor.test23_p1_meter_active_power",
"p1_phase_export_entities": [],
"p1_phase_import_entities": [],
"p1_phase_net_entities": [],
"peak_cap_w": 3500,
"peak_forecast_entity": "",
"peak_soc_floor": 20,
"price_avg_entity": "",
"price_csv_path": "/share/goodwe_prices.csv",
"price_export_formula": "",
"price_feed_url": "https://api.energy-charts.info/price?bzn=BE",
"price_formula": "",
"price_horizon_h": 48,
"price_markup_eur_kwh": 0.03,
"price_now_entity": "",
"price_provider": "generic_dayahead",
"price_taxes_eur_kwh": 0.06,
"price_taxes_profile": "",
"price_timeout_s": 10,
"pv_entities": [],
"pv_entity": "",
"saturation_cycles": 3,
"saturation_w": 500,
"setpoint_entity": "",
"shadow_mode": "auto",
"sign_disagree_s": 180,
"sign_disagree_w": 300,
"site_sign_disagree_s": 325,
"site_sign_disagree_w": 300,
"slew_w": 0,
"soc_entity": "sensor.test23_soc",
"stale_input_s": 15,
"static_profile": "",
"step_w": 10,
"target_grid_w": -10,
"unit_sign_disagree_s": 85,
"unit_sign_disagree_w": 250
}
@@ -0,0 +1,73 @@
{
"arbitrage_enabled": false,
"arbitrage_soc_ceiling": 95,
"arbitrage_soc_floor": 20,
"auto_start": false,
"batt_entity": "sensor.test23_battery_power",
"batt_invert": false,
"bms_soc_floor": 10,
"circulation_hold_s": 75,
"circulation_w": 700,
"cycle_cost_threshold_eur": 0.1,
"cycle_floor_s": 15,
"deadband_w": 15,
"delivery_hold_s": 185,
"estop_fitted": false,
"export_price_eur_kwh": 0.04,
"gain": 0.6,
"heartbeat_s": 10,
"integrator_max_w": 0,
"inverters": [],
"log_level": "info",
"maintenance_charge_w": 2000,
"maintenance_discharge_w": 2000,
"maintenance_enabled": false,
"maintenance_hold_min": 120,
"maintenance_interval_days": 28,
"maintenance_soc_floor": 11,
"maintenance_soc_target": 99,
"maintenance_start_hour": 10,
"max_w": 2000,
"meter_entity": "sensor.p1_meter_active_power",
"meter_freeze_s": 300,
"meter_invert": false,
"meter_max_age_s": 30,
"meter_mqtt_topic": "",
"meter_phases": 1,
"meter_poll_s": 5,
"meter_source": "ha_signed",
"p1_export_entity": "",
"p1_host": "",
"p1_import_entity": "",
"p1_net_entity": "sensor.test23_p1_meter_active_power",
"p1_phase_export_entities": [],
"p1_phase_import_entities": [],
"p1_phase_net_entities": [],
"peak_cap_w": 3500,
"peak_forecast_entity": "",
"peak_soc_floor": 20,
"price_avg_entity": "",
"price_csv_path": "/share/goodwe_prices.csv",
"price_feed_url": "https://api.energy-charts.info/price?bzn=BE",
"price_horizon_h": 48,
"price_markup_eur_kwh": 0.03,
"price_now_entity": "",
"price_provider": "generic_dayahead",
"price_taxes_eur_kwh": 0.06,
"price_timeout_s": 10,
"saturation_cycles": 3,
"saturation_w": 500,
"setpoint_entity": "number.test23_setpoint_w",
"sign_disagree_s": 180,
"sign_disagree_w": 300,
"site_sign_disagree_s": 325,
"site_sign_disagree_w": 300,
"slew_w": 0,
"soc_entity": "sensor.test23_soc",
"stale_input_s": 15,
"static_profile": "",
"step_w": 10,
"target_grid_w": -10,
"unit_sign_disagree_s": 85,
"unit_sign_disagree_w": 250
}
@@ -0,0 +1,73 @@
{
"arbitrage_enabled": true,
"arbitrage_soc_ceiling": 95,
"arbitrage_soc_floor": 20,
"auto_start": true,
"batt_entity": "sensor.test23_battery_power",
"batt_invert": false,
"bms_soc_floor": 10,
"circulation_hold_s": 75,
"circulation_w": 700,
"cycle_cost_threshold_eur": 0.1,
"cycle_floor_s": 15,
"deadband_w": 15,
"delivery_hold_s": 185,
"estop_fitted": false,
"export_price_eur_kwh": 0.04,
"gain": 0.6,
"heartbeat_s": 10,
"integrator_max_w": 0,
"inverters": [],
"log_level": "info",
"maintenance_charge_w": 2000,
"maintenance_discharge_w": 2000,
"maintenance_enabled": false,
"maintenance_hold_min": 120,
"maintenance_interval_days": 28,
"maintenance_soc_floor": 11,
"maintenance_soc_target": 99,
"maintenance_start_hour": 10,
"max_w": 2000,
"meter_entity": "sensor.p1_meter_active_power",
"meter_freeze_s": 300,
"meter_invert": false,
"meter_max_age_s": 30,
"meter_mqtt_topic": "",
"meter_phases": 1,
"meter_poll_s": 5,
"meter_source": "ha_signed",
"p1_export_entity": "",
"p1_host": "",
"p1_import_entity": "",
"p1_net_entity": "sensor.test23_p1_meter_active_power",
"p1_phase_export_entities": [],
"p1_phase_import_entities": [],
"p1_phase_net_entities": [],
"peak_cap_w": 15000,
"peak_forecast_entity": "",
"peak_soc_floor": 20,
"price_avg_entity": "",
"price_csv_path": "/share/goodwe_prices.csv",
"price_feed_url": "",
"price_horizon_h": 48,
"price_markup_eur_kwh": 0.03,
"price_now_entity": "",
"price_provider": "manual_csv",
"price_taxes_eur_kwh": 0.06,
"price_timeout_s": 10,
"saturation_cycles": 3,
"saturation_w": 500,
"setpoint_entity": "number.test23_setpoint_w",
"sign_disagree_s": 180,
"sign_disagree_w": 300,
"site_sign_disagree_s": 325,
"site_sign_disagree_w": 300,
"slew_w": 0,
"soc_entity": "sensor.test23_soc",
"stale_input_s": 15,
"static_profile": "",
"step_w": 10,
"target_grid_w": -10,
"unit_sign_disagree_s": 85,
"unit_sign_disagree_w": 250
}
+21 -7
View File
@@ -497,8 +497,13 @@ check(f"AC 1: NOT ONE of the {len(emitted)} values that reached the device "
# largest emitted value is what it is and not 5000 W. The clamp is what makes it
# bounded; the freeze is what makes it small. A check that read
# `max(emitted) == max_w` would have been asserting the freeze, not the clamp.
# SAFETY-52 re-baseline: an inverter reporting 0 W for SETTLE_CYCLES is a
# battery that refuses, so the command then drops to 0 W. The freeze still
# engaged first, and the event log says so.
check(f"...and the saturation freeze is what pins it at {max(emitted):,.0f} W "
f"rather than the rail", ctl_r.sat_count >= ctl_r.tuning.saturation_cycles)
f"rather than the rail",
any("saturation freeze" in e for e in ctl_r.events)
and max(emitted) < LIVE_MAX_W)
notes_r = clamp_notes(hass_r)
print(f" the loop clamped on {ctl_r.clamp_wd.engagements} of {60} cycles, "
@@ -521,7 +526,8 @@ check(f"the action log records every engagement, coalesced into one row per "
f"episode ({len(rows_r)} row(s), {ctl_r.clamp_wd.engagements} "
f"engagement(s))",
len(rows_r) == ctl_r.clamp_wd.episodes
and f"{ctl_r.clamp_wd.engagements} engagement(s)" in rows_r[0])
and messages.count(ctl_r.clamp_wd.engagements, "engagement")
in rows_r[0])
# ⚠️ REGRESSION, AND IT WAS A REAL BUG BEFORE IT WAS A CHECK. `log_event()` keeps
# 40 rows. A row per engagement flushes that ring inside 40 cycles of a winding
@@ -538,7 +544,8 @@ check(f"a long winding episode does NOT flood the 40-row event log "
f"({len(rows_l)} rows for {ctl_l.clamp_wd.engagements} engagements)",
ctl_l.clamp_wd.engagements > 40 and len(rows_l) <= ctl_l.clamp_wd.episodes)
check("...and the count in the row is the counter's, so nothing is lost",
f"{ctl_l.clamp_wd.engagements} engagement(s)" in nth(rows_l, -1))
messages.count(ctl_l.clamp_wd.engagements, "engagement")
in nth(rows_l, -1))
# The RED row exists only while engaged, and the episode above is short, so it
# is captured mid-run rather than asserted after the hysteresis has cleared it.
check("the status page flags it WHILE it is engaged - amber, since it is the "
@@ -578,8 +585,12 @@ check("UX-07 item 1: during a bound episode an earlier over-rating count is "
# ⚠️ NOT A TRIP. 11.2's action is "clamp and alarm"; the loop keeps running and
# keeps writing the clamped value. If a later cut changes that it must come here.
check(f"it is NOT a trip - the command stands at {ctl_r.target:+.0f} W, not 0 W",
ctl_r.target != 0.0 and ctl_r.target == hass_r.writes[-1])
# SAFETY-52: the loop itself now asks 0 W of an inverter that gives nothing,
# with its own reason. That is the loop's decision, not a stop.
check(f"it is NOT a trip - the command stands at {ctl_r.target:+.0f} W because "
f"the loop says '{ctl_r.loop_reason}', not because of a stop",
ctl_r.loop_reason == "battery refuses"
and ctl_r.target == hass_r.writes[-1])
check("...and the controller still reports itself running, not failsafe",
ctl_r.auto and not ctl_r.sign_wd.tripped)
@@ -2051,9 +2062,12 @@ check("it still NOTIFIES (not suppressed), under a title that claims no bug",
check("...under its OWN notification_id, so it cannot replace a BUG SIGNAL "
"notice still on screen",
notes_i and all(n["notification_id"] == BOUND_ID for n in notes_i))
# UX-11: the WARNING quotes the code. The reason is on the DEBUG line beside
# it (test_messages.py part 6).
check("...logged as a WARNING, not an ERROR",
any(x.levelno == logging.WARNING and "reached its" in x.getMessage()
for x in log_i)
any(x.levelno == logging.WARNING
and x.getMessage().startswith("The battery gives less than asked: "
"OUTPUT_CLAMP.") for x in log_i)
and not any(x.levelno >= logging.ERROR and "OUTPUT_CLAMP" in x.getMessage()
for x in log_i))
check("...and the status row is amber, not red",
+8 -3
View File
@@ -1147,8 +1147,10 @@ async def _one():
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": 0.6,
# ⚠️ THE SAME 1 s AS THE TWO-INVERTER FIXTURE, AND THAT IS WHAT
# MAKES THIS SECTION NON-VACUOUS. The run below is 2 s of wall clock
# against a 1 s window, so a hold is not what stops this firing -
# MAKES THIS SECTION NON-VACUOUS. The run below is 1.1 s of wall
# clock against a 1 s window (SAFETY-52 shortened it from 2 s, and
# "the window was never even opened" below is what still makes it
# non-vacuous), so a hold is not what stops this firing -
# the reduction is. With a shipped-length hold "nothing was
# reported" would be true of a fixture that simply ran out of time.
"bms_soc_floor": _FLOOR_PCT, "delivery_hold_s": 1,
@@ -1158,7 +1160,10 @@ async def _one():
c.inverters[0].dev_min, c.inverters[0].dev_max = -2000.0, 2000.0
c.auto = True
hass.ctrl = c
await _drive(c, n=20, dt=0.1)
# SAFETY-52: from SETTLE_CYCLES of delivering nothing the loop asks 0 W
# (the battery refuses), so the run stops just before that. 11 cycles is
# still 1.1 s against the 1 s hold.
await _drive(c, n=11, dt=0.1)
return c, hass, store
+6 -1
View File
@@ -1813,6 +1813,11 @@ _S56_ACCUSATIONS = [
]
_log56 = [r.getMessage() for r in _LOGREC[_S56_LOG0:]
if "battery power reading stopped changing" in r.getMessage()]
# UX-11: the ERROR line quotes the code, and the reason itself is on the DEBUG
# line logged beside it.
_dbg56 = [r.getMessage() for r in _LOGREC[_S56_LOG0:]
if r.levelno == logging.DEBUG
and r.getMessage().startswith("Evidence for ")] or [""]
def _s56_row(c):
@@ -1855,7 +1860,7 @@ check("PRECONDITION: all four operator-facing surfaces were really produced by "
"two are the same string, which is 11b again on the log surface",
len(_log56) == 2 and _log56[0] == _log56[1]
and all(len(s) > 30 for s in _S56_SURFACES.values())
and _r56_ref in _log56[-1])
and _log56[-1].endswith(": STALE_READING.") and _r56_ref in _dbg56[-1])
_idx56 = [_r56_ref.find(t) for _w, t in _S56_EXPLANATIONS]
check(f"11c. BOTH EXPLANATIONS ARE NAMED, AND IN THAT ORDER: "
f"{_S56_EXPLANATIONS[0][1]!r} at {_idx56[0]} then "
+227
View File
@@ -0,0 +1,227 @@
"""UX-13 P0: the entity list for the picker. `python3 test_haentities.py`
`GET ha/entities` reads Home Assistant's states through the add-on's own
session (hass.states()) and must never fail the page: part 1 drives the real
HomeAssistant client against a local server that answers 502, garbage, the
wrong shape, nothing at all, or too slowly. Part 2 checks the 30 s cache and
what is served while Home Assistant is down. Part 3 serves the real route.
Mutating a module this file grades? Read MUTATION.md first (purge __pycache__).
"""
import asyncio
import json
import sys
import time
from aiohttp import ClientSession, web as aioweb
from app import hass as H, haentities as E, web
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
STATES = [
{"entity_id": "sensor.grid", "state": "812",
"attributes": {"friendly_name": "Grid power", "unit_of_measurement": "W",
"device_class": "power"}},
{"entity_id": "sensor.soc", "state": "54",
"attributes": {"friendly_name": "Battery level", "unit_of_measurement": "%",
"device_class": "battery"}},
{"entity_id": "number.setpoint", "state": "0", "attributes": {}},
{"entity_id": "sensor.pv_kw", "state": "1.2",
"attributes": {"unit_of_measurement": "kW"}},
{"no_entity_id": True},
]
async def serve(handler):
app = aioweb.Application()
app.router.add_get("/api/states", handler)
runner = aioweb.AppRunner(app)
await runner.setup()
site = aioweb.TCPSite(runner, "127.0.0.1", 0)
await site.start()
return runner, site._server.sockets[0].getsockname()[1]
async def read_with(handler, timeout_s=10):
runner, port = await serve(handler)
H.CORE_API, H.STATES_TIMEOUT_S = f"http://127.0.0.1:{port}/api", timeout_s
try:
async with ClientSession() as session:
t0 = time.monotonic()
got = await H.HomeAssistant(session, "token").states()
read_with.took = time.monotonic() - t0
return got
finally:
await runner.cleanup()
async def ok(_r):
return aioweb.json_response(STATES)
async def bad_gateway(_r):
return aioweb.Response(status=502)
async def garbage(_r):
return aioweb.Response(text="<html>", content_type="application/json")
async def not_a_list(_r):
return aioweb.json_response({"message": "hi"})
async def slow(_r):
await asyncio.sleep(2)
return aioweb.json_response(STATES)
async def closed_port():
H.CORE_API = "http://127.0.0.1:9/api"
async with ClientSession() as session:
return await H.HomeAssistant(session, "token").states()
print("1. hass.states() answers None, never an exception")
check("a normal answer is the state list", asyncio.run(read_with(ok)) == STATES)
for name, handler in (("502 while HA restarts", bad_gateway),
("a body that is not JSON", garbage),
("JSON that is not a list", not_a_list)):
check(f"{name} -> None", asyncio.run(read_with(handler)) is None)
check("an answer slower than the timeout -> None, at the timeout",
asyncio.run(read_with(slow, timeout_s=0.3)) is None
and read_with.took < 1.0)
check("no server at all -> None", asyncio.run(closed_port()) is None)
check("the timeout for the list is the same 10 s as every other read",
"STATES_TIMEOUT_S = 10 " in open(H.__file__, encoding="utf-8").read())
class FakeHass:
def __init__(self):
self.answer, self.reads = STATES, 0
async def states(self):
self.reads += 1
await asyncio.sleep(0.01)
return self.answer
class Clock:
def __init__(self):
self.t = 1000.0
def __call__(self):
return self.t
print("\n2. the cache, and Home Assistant being down")
_h, _c = FakeHass(), Clock()
_cache = E.EntityCache(_h, clock=_c)
async def burst():
return await asyncio.gather(*(_cache.payload("power") for _ in range(5)))
_p = asyncio.run(burst())
check("five pickers opening at once cost one read of Home Assistant",
_h.reads == 1 and all(x == _p[0] for x in _p))
_ids = [r["entity_id"] for r in _p[0]["entities"]]
check("power entities come first, then the rest, and a broken state is left "
f"out ({_ids})", _ids == ["sensor.grid", "sensor.pv_kw",
"number.setpoint", "sensor.soc"]
and [r["match"] for r in _p[0]["entities"]] == [True, True, False, False])
check("each row carries id, name, state, unit and device class",
_p[0]["entities"][0] == {"entity_id": "sensor.grid", "name": "Grid power",
"state": "812", "unit": "W",
"device_class": "power", "match": True})
check("the kinds filter as the pickers need",
[r["entity_id"] for r in _p[0]["entities"]
if E.matches(r, "pct")] == ["sensor.soc"]
and [r["entity_id"] for r in _p[0]["entities"]
if E.matches(r, "number")] == ["number.setpoint"])
_c.t += 10
asyncio.run(_cache.payload())
check("within 30 s the cached list is served", _h.reads == 1)
check("peek() hands the validator the fresh list without a read",
set(_cache.peek()) == set(_ids) and _h.reads == 1)
_h.answer = None
_c.t += 30
_down = asyncio.run(_cache.payload())
check("Home Assistant down after a good read: the old list, marked old",
_h.reads == 2 and _down["available"] and _down["text"] == E.STALE_TEXT
and len(_down["entities"]) == 4 and _down["age_s"] >= 30)
check("...and peek() then gives nothing, so no warning rests on an old list",
_cache.peek() is None)
async def down_windows():
"""One loop throughout: a contended asyncio.Lock binds to its loop."""
hass, clock = FakeHass(), Clock()
hass.answer = None
cache = E.EntityCache(hass, clock=clock)
counts = []
for step in (0, 1, 30):
clock.t += step
await asyncio.gather(*(cache.payload() for _ in range(5)))
counts.append(hass.reads)
return counts
check("five polls while Home Assistant is down cost one read, the polls just "
"after wait for the next window, and that window tries once",
asyncio.run(down_windows()) == [1, 1, 2])
_h2 = FakeHass()
_h2.answer = None
_empty = asyncio.run(E.EntityCache(_h2).payload("power"))
check("Home Assistant down from the start: an empty list that says why",
_empty == {"available": False, "text": E.DOWN_TEXT, "entities": []})
print("\n3. the route")
class FakeController:
def __init__(self, hass):
self.hass, self.o = hass, {}
async def route(hass, query=""):
app = web.build_app(FakeController(hass), selfcfg=object())
runner = aioweb.AppRunner(app)
await runner.setup()
site = aioweb.TCPSite(runner, "127.0.0.1", 0)
await site.start()
port = site._server.sockets[0].getsockname()[1]
try:
async with ClientSession() as s:
async with s.get(f"http://127.0.0.1:{port}/ha/entities{query}") as r:
return r.status, await r.json()
finally:
await runner.cleanup()
_st, _body = asyncio.run(route(FakeHass(), "?kind=pct"))
check("GET ha/entities?kind=pct answers 200 with the matching entity first",
_st == 200 and _body["entities"][0]["entity_id"] == "sensor.soc")
_st, _body = asyncio.run(route(_h2))
check("with Home Assistant down it still answers 200, with the reason",
_st == 200 and _body["available"] is False and _body["entities"] == [])
check("the words shown are short and plain (STYLE: one sentence)",
all(len(t.split()) <= 12 and t.count(".") == 1
for t in (E.DOWN_TEXT, E.STALE_TEXT)))
print(json.dumps(_body))
print()
if fails:
print(f"{len(fails)} FAILED")
sys.exit(1)
print("all passed")
+293 -25
View File
@@ -26,6 +26,7 @@ Run `python3 -B test_messages.py --violations` to print what part 3 sees.
import ast
import hashlib
import json
import os
import re
import sys
@@ -388,6 +389,9 @@ LIMITS = { # kind: (words, keys ok, entity ids ok)
"log": (25, True, True),
"option-name": (6, False, False),
"option-desc": (30, True, True),
"note": (25, True, True), # UX-13: a settings-page warning
"ui-name": (6, False, False), # UX-13: app/ui_text, a name or choice
"ui-desc": (25, False, False), # UX-13: app/ui_text, one-line help
}
LOG_CALL = re.compile(r"(?:^|\.)(?:_LOG|log|logger|LOG)\.(warning|error|critical|exception)$")
@@ -453,6 +457,10 @@ def collect():
if arg is not None:
for n, t in strings_in(arg):
out.append(("log", f"{f.name}:{n.lineno}", t))
elif name.endswith("_advise") and node.args:
for n, t in strings_in(node.args[-1], expand=True):
if len(words(t)) > 1:
out.append(("note", f"{f.name}:{n.lineno}", t))
elif re.search(r"problems\.(append|extend)$", name):
for a in node.args:
for n, t in strings_in(a, expand=True):
@@ -475,6 +483,16 @@ def collect():
if isinstance(v.get("fields"), dict):
walk(v["fields"], f"{path}{key}.")
walk(tr.get("configuration"), "")
# UX-13: the new page's own words, held to the option texts' rule.
for f in sorted((APP / "ui_text").glob("*.json")):
def walk_ui(node, path):
for key, v in node.items():
if isinstance(v, dict):
walk_ui(v, f"{path}{key}.")
elif isinstance(v, str):
out.append(("ui-desc" if key == "description" else
"ui-name", f"{f.name}:{path}{key}", v))
walk_ui(json.loads(f.read_text(encoding="utf-8")), "")
return out
@@ -485,6 +503,8 @@ def problems_of(kind, text):
p.append(f"over {lim} words ({len(words(text))})")
if ";" in text:
p.append("semicolon")
if kind in ("note", "ui-desc") and sentences(text) > 1:
p.append(f"over 1 sentence ({sentences(text)})")
return p + text_problems(text, keys=keys, entities=ents)
@@ -877,6 +897,7 @@ DATA = {
"main.py:messages.when(brussels(self.tariff_at))",
"main.py:messages.duration(TARIFF_MAX_AGE_S)",
"main.py:messages.count(len(targets), 'inverter')",
"main.py:messages.seconds(self.p1.max_age_s)",
# maintenance.py, mqtt.py, p1.py
"maintenance.py:phase", "mqtt.py:err", "p1.py:err", "p1.py:self.host",
"p1.py:self.topic", "p1.py:poll_s", "p1.py:ingest.max_age_s",
@@ -1047,20 +1068,35 @@ def _static(spec):
return [t for t in out if len(words(t)) > 1]
# UX-11: a WARNING+ line quotes a safety reason by its code only. The reason,
# with its figures, is on a DEBUG line beside it and in the action log.
SAFETY_REASONS = {
"sign": _sign_texts, "circulation": _circ_texts,
"delivery": _delivery_texts, "clamp": _clamp_texts, "peak": _peak_texts,
"freeze": _freeze_texts, "stale": _stale_texts,
}
def _coded(maker):
"""The codes a WARNING+ line shows for the reasons `maker` builds, plus
the fallback for a restored stop with no reason saved."""
return lambda: ([messages.reason_code(t) for t in maker()]
+ [messages.reason_code("")])
TEXT = {
"main.py:first.sign_wd.reason": _sign_texts,
"main.py:inv.sign_wd.reason": _sign_texts,
"main.py:inv.sign_wd.reason or '(reason not recorded)'": _sign_texts,
"main.py:self.site_sign_wd.reason": _sign_texts,
"main.py:self.site_sign_wd.reason or '(reason not recorded)'": _sign_texts,
"main.py:self.circ_wd.reason": _circ_texts,
"main.py:self.circ_wd.reason or '(reason not recorded)'": _circ_texts,
"main.py:inv.delivery_wd.reason": _delivery_texts,
"main.py:inv.delivery_wd.reason or '(reason not recorded)'": _delivery_texts,
"main.py:self.clamp_wd.reason": _clamp_texts,
"main.py:g.reason": _peak_texts,
"main.py:self.freeze_wd.reason": _freeze_texts,
"main.py:inv.batt_fresh.reason": _stale_texts,
"main.py:messages.reason_code(first.sign_wd.reason)": _coded(_sign_texts),
"main.py:messages.reason_code(inv.sign_wd.reason)": _coded(_sign_texts),
"main.py:messages.reason_code(self.site_sign_wd.reason)":
_coded(_sign_texts),
"main.py:messages.reason_code(self.circ_wd.reason)": _coded(_circ_texts),
"main.py:messages.reason_code(inv.delivery_wd.reason)":
_coded(_delivery_texts),
"main.py:messages.reason_code(self.clamp_wd.reason)": _coded(_clamp_texts),
"main.py:messages.reason_code(g.reason)": _coded(_peak_texts),
"main.py:messages.reason_code(self.freeze_wd.reason)":
_coded(_freeze_texts),
"main.py:messages.reason_code(inv.batt_fresh.reason)": _coded(_stale_texts),
"main.py:rep.explain()": _migration_texts,
"store.py:rep.explain()": _migration_texts,
"main.py:plan.words": _tariff_texts,
@@ -1086,6 +1122,26 @@ TEXT = {
}
# UX-11: a WARNING+ line, as logged with its built text filled in, is at most
# 25 words (STYLE.md). These families are not safety reasons and were not
# rewritten by UX-11. Each is listed with why, the list may only shrink
# (LONG_LINE_CAP), and a listed key that no longer runs long fails.
LONG_LINE_OK = {
"main.py:plan.words": "tariff plan words, TARIFF-11 pins them, follow-up",
"static_tariff.py:read.reason": "price feed reasons, follow-up",
"main.py:rep.explain()": "state migration report, names saved keys",
"store.py:rep.explain()": "state migration report, names saved keys",
"main.py:refusal": "write refusals, a software fault only",
"main.py:' / '.join(resolution.scope_errors)":
"claim scope errors, a software fault only",
"maintenance.py:msg": "maintenance gate reasons, follow-up",
"price_forecast.py:gate.reason": "trading gate reasons, follow-up",
"price_history.py:self.last_error": "price history errors, follow-up",
}
LONG_LINE_CAP = 9
LINE_WORDS = 25
def reason_problems(text):
"""STYLE.md's red-alarm shape, for a text a log line quotes."""
out = []
@@ -1133,10 +1189,12 @@ def _fill(template, fmt_node, key_part, sample):
return template # %-style: filled by the caller
def scan_log_lines(files, text=None, data=None):
def scan_log_lines(files, text=None, data=None, long_ok=None, long_seen=None):
"""-> (unclassified keys, stale keys, [(key, sample, problems)])."""
text = TEXT if text is None else text
data = DATA if data is None else data
long_ok = LONG_LINE_OK if long_ok is None else long_ok
long_seen = set() if long_seen is None else long_seen
seen, bad = set(), []
for fname, tree in files:
for key, call in dynamic_parts(tree, fname):
@@ -1162,6 +1220,11 @@ def scan_log_lines(files, text=None, data=None):
line = PLACEHOLDER.sub("X", line).replace("\0", sample)
p += [f"as logged: {x}" for x in line_problems(line)
+ logged_shape(line) if x not in p]
if len(words(line)) > LINE_WORDS:
long_seen.add(key)
if key not in long_ok:
p.append(f"as logged: over {LINE_WORDS} words "
f"({len(words(line))})")
if p:
bad.append((key, sample, p))
unknown = sorted(seen - set(data) - set(text))
@@ -1171,14 +1234,81 @@ def scan_log_lines(files, text=None, data=None):
_FILES = [(f.name, ast.parse(f.read_text(encoding="utf-8")))
for f in sorted(APP.glob("*.py"))]
_unknown, _stale, _bad = scan_log_lines(_FILES)
_long_seen = set()
_unknown, _stale, _bad = scan_log_lines(_FILES, long_seen=_long_seen)
for k, sample, p in _bad:
print(f" BAD {k}: {'; '.join(p)} :: {sample[:110]!r}")
print(f" BAD {k}: {'; '.join(p)} :: {sample!r}")
check(f"every dynamic part of a WARNING+ line is classified as data or as a "
f"built text (unclassified: {_unknown})", not _unknown)
check(f"...and no classification is left over from a line that is gone "
f"(stale: {_stale})", not _stale)
_n_texts = sum(len(m()) for m in TEXT.values() if m is not None)
check(f"UX-11: no WARNING+ line runs over {LINE_WORDS} words as logged, except "
f"the {len(LONG_LINE_OK)} listed families, and none of them is a safety "
f"reason (cap {LONG_LINE_CAP})",
len(LONG_LINE_OK) <= LONG_LINE_CAP
and not any("reason_code" in k
or TEXT.get(k) in SAFETY_REASONS.values()
for k in LONG_LINE_OK))
check(f"...and every listed family still runs long, so the list only shrinks "
f"(no longer long: {sorted(set(LONG_LINE_OK) - _long_seen)})",
set(LONG_LINE_OK) <= _long_seen)
def _code_lines_without_evidence(files):
"""WARNING+ calls quoting `messages.reason_code(X)` whose next statement
is not a DEBUG call that logs X itself (UX-11: nothing is lost)."""
out, n = [], 0
for fname, tree in files:
for node in ast.walk(tree):
for body in (getattr(node, f, None) for f in ("body", "orelse")):
if not isinstance(body, list):
continue
for i, st in enumerate(body):
call = st.value if isinstance(st, ast.Expr) else None
if not (isinstance(call, ast.Call)
and LOG_CALL.search(ast.unparse(call.func))):
continue
coded = [a.args[0] for a in call.args
if isinstance(a, ast.Call) and a.args
and ast.unparse(a.func) == "messages.reason_code"]
if not coded:
continue
n += 1
nxt = body[i + 1] if i + 1 < len(body) else None
dbg = (nxt.value if isinstance(nxt, ast.Expr)
and isinstance(nxt.value, ast.Call)
and ast.unparse(nxt.value.func).endswith(".debug")
else None)
want = ast.unparse(coded[0])
if dbg is None or not any(
ast.unparse(a) == want
or ast.unparse(a).startswith(want + " or ")
for a in dbg.args):
out.append(f"{fname}:{call.lineno}")
return n, out
_n_coded, _no_evidence = _code_lines_without_evidence(_FILES)
check(f"every WARNING+ line that quotes a reason code ({_n_coded}) has the "
f"reason itself on a DEBUG line right after it (missing: {_no_evidence})",
_n_coded >= 14 and not _no_evidence)
_n_m, _m_bad = _code_lines_without_evidence([("x.py", ast.parse(
"_LOG.error('Stop: %s.', messages.reason_code(wd.reason))\n"
"_LOG.debug('Something else.')\n"))])
check("...and a line whose DEBUG evidence was dropped is caught",
_n_m == 1 and _m_bad == ["x.py:1"])
_evidence_bad = [(n, t, reason_problems(t)) for n, m in SAFETY_REASONS.items()
for t in m() if reason_problems(t)]
check(f"the safety reasons behind those lines, on the DEBUG line and in the "
f"action log, keep the red-alarm shape ({_evidence_bad})",
not _evidence_bad)
_codes = {n: [messages.reason_code(t) for t in m()]
for n, m in SAFETY_REASONS.items()}
check(f"...and every one carries a code the line can quote ({_codes})",
all(re.fullmatch(r"[A-Z]+(?:_[A-Z]+)+", c)
and c not in (messages.NO_REASON_SAVED, messages.NO_REASON_CODE)
for cs in _codes.values() for c in cs))
check(f"every built text, run for real, obeys the rule, and so does the line "
f"that quotes it ({_n_texts} texts, {len(_bad)} bad)", not _bad)
_counts = [f"{f}:{n.lineno}" for f, t in _FILES for n in ast.walk(t)
@@ -1208,29 +1338,43 @@ _clamp_lines = {
"error, write": (_clamp_line("Power request too high"), _w1),
"warning, loop": (_clamp_line("The battery gives less than asked"), _at),
}
_clamp_shown = {k: (f % (r, messages.times(1)) if f else None)
_clamp_shown = {k: (f % (messages.reason_code(r), messages.times(1))
if f else None)
for k, (f, r) in _clamp_lines.items()}
for k, v in _clamp_shown.items():
print(f" {k}: {v!r} ({len(words(v or ''))} words)")
check("the clamp lines for one inverter are at most 3 sentences and 30 words, "
"and keep OUTPUT_CLAMP and the numbers",
all(v and sentences(v) <= 3 and len(words(v)) <= 30
check("UX-11: the clamp lines are at most 25 words and keep OUTPUT_CLAMP and "
"the count, and the numbers are in the reason the DEBUG line beside "
"them logs",
all(v and len(words(v)) <= LINE_WORDS
and "OUTPUT_CLAMP" in v and "1 time so far" in v
for v in _clamp_shown.values())
and all(x in _clamp_shown["error, loop"]
for x in ("+9000 W", "+5000 W", "+2000 W", "software fault")))
and "+9000" not in v for v in _clamp_shown.values())
and "software fault" in _clamp_shown["error, loop"]
and all(x in _over for x in ("+9000 W", "+5000 W", "+2000 W")))
# Mutations: the scan catches what the 2d scan missed.
_OLD_CLAMP = ("OUTPUT_CLAMP: the loop computed +2148 W, over the 2000 W rating, "
"and it was clamped to +2000 W; the loop's command this cycle was "
"+440 W. This is a BUG SIGNAL, not a limit being used: something "
"upstream computed a setpoint the actuator cannot deliver.")
_mut_text = dict(TEXT, **{"main.py:self.clamp_wd.reason": lambda: [_OLD_CLAMP]})
_mut_text = dict(TEXT, **{"main.py:messages.reason_code(self.clamp_wd.reason)":
lambda: [_OLD_CLAMP]})
_u, _s, _b = scan_log_lines([f for f in _FILES if f[0] == "main.py"],
text=_mut_text)
check("an injected bad reason (the 2d clamp text) is caught, on both clamp "
f"lines ({sorted({k for k, _t, _p in _b if 'clamp' in k})})",
[k for k, _t, _p in _b].count("main.py:self.clamp_wd.reason") == 2)
[k for k, _t, _p in _b].count(
"main.py:messages.reason_code(self.clamp_wd.reason)") == 2)
# UX-11: the line that quoted the whole STALE_READING reason (60 words on
# TEST-23) is caught by the length rule alone.
_old_stale = dict(TEXT, **{"main.py:messages.reason_code(inv.batt_fresh.reason)":
_stale_texts})
_u, _s, _b = scan_log_lines([f for f in _FILES if f[0] == "main.py"],
text=_old_stale)
check("...and the UX-10 stale line, which quoted the whole reason, is caught "
f"for its length ({[p for k, _t, p in _b if 'batt_fresh' in k][:1]})",
any("batt_fresh" in k and any(f"over {LINE_WORDS} words" in x for x in p)
for k, _t, p in _b))
_new_site = ast.parse("_LOG.warning('Something broke: %s', self.new_wd.reason)")
_u, _s, _b = scan_log_lines([("main.py", _new_site)])
check(f"...and a new line quoting a text nobody classified is caught ({_u})",
@@ -1275,6 +1419,8 @@ import logging # noqa: E402
from app import hass as _hass, p1 as _p1, validate as _validate, web as _web # noqa: E402
from app.arbiter import Claim # noqa: E402
from app.main import Controller, why_key # noqa: E402
from app import control as _control # noqa: E402
from app import main as _main # noqa: E402
class _Rec(logging.Handler):
@@ -1460,6 +1606,11 @@ for _f in sorted(APP.glob("*.py")):
_keys = {why_key(s, [Claim.set(s, 0, 0.0, r)]) for s, r in _SOURCES}
_keys |= {why_key("failsafe", []),
why_key("failsafe", [Claim.set("loop", 0, 1.0, "tracking")])}
# SAFETY-52: the loop's claim reason is computed, so the scan cannot see it.
_keys |= {why_key("loop", [Claim.set("loop", 0, 0.0, _r)])
for _r in (_control.REFUSED, _control.PROBING)}
check("...including the loop's two battery-refuses reasons, which get words of "
"their own", {_control.REFUSED, _control.PROBING} <= _keys)
check(f"the scan found the claims ({len(_SOURCES)}), including the latched "
f"per-inverter stop the 2d test saw as 'Other'",
("failsafe", "sign disagreement") in _SOURCES and len(_SOURCES) >= 8)
@@ -1487,6 +1638,9 @@ class _H:
async def call(self, *a, **k):
return True
async def set_number(self, *a, **k):
return True
class _S:
data = {}
@@ -1549,6 +1703,120 @@ _c.why_words = "Keeping the grid near zero: 0 W"
check("...and once a cycle decides again, the line is that decision",
_c.why_words == "Keeping the grid near zero: 0 W")
# UX-11 item 3: past the hold, the Why line says which reading is missing,
# not "A reading is missing: 0 W". Driven through cycle() for real.
_c.inputs_bad_since = _dt.now(_tz.utc) - _td(seconds=20)
asyncio.run(_c.cycle())
check(f"past the hold, the Why line names the missing reading "
f"({_c.why_words!r})",
_c.why_words == "No usable meter reading for over 15 seconds: 0 W")
# UX-11 item 2: the red meter row says the log shows why. A meter that goes
# quiet logs one WARNING per episode, not one per cycle, and INFO when back.
_c.p1_enabled = True
_c.p1 = _p1.P1Ingest(max_age_s=30.0)
def _meter_at(age_s):
import time as _time
_c.p1.submit(_p1.make_sample(_p1.SOURCE_HA, 500.0, 0.0, phases=1,
ingest_mono=_time.monotonic() - age_s))
def _quiet_episodes():
# Two quiet episodes close together, then a third 10 minutes on.
for age in (1, 40, 45, 50, 1, 2, 60, 65, 1):
_meter_at(age)
asyncio.run(_c.read_inputs())
_c._meter_quiet_warned -= _main.METER_QUIET_REPEAT_S
for age in (40, 45, 1):
_meter_at(age)
asyncio.run(_c.read_inputs())
_mq = [r for r in _captured("goodwe", _quiet_episodes)
if "meter" in r.getMessage().lower()]
_mq_warn = [r.getMessage() for r in _mq if r.levelno == logging.WARNING]
_mq_info = [r.getMessage() for r in _mq if r.levelno == logging.INFO]
_mq_dbg = [r.getMessage() for r in _mq if r.levelno == logging.DEBUG]
check(f"a meter that goes quiet logs one WARNING per episode, not per cycle, "
f"and one INFO when readings return, and a flapping meter at most one "
f"pair per {_main.METER_QUIET_REPEAT_S:.0f} s ({_mq_warn}, {_mq_info}, "
f"{_mq_dbg})",
len(_mq_warn) == 2 and _mq_info == ["Meter readings are back."] * 2
and len(_mq_dbg) == 2
and _mq_warn[0] == "No meter reading for over 30 seconds, so control "
"waits and then sets the battery to 0 W."
and len(words(_mq_warn[0])) <= LINE_WORDS)
# UX-11 item 1: a state file saved before UX-11 holds the long reasons, and
# they load unchanged. The ERROR line at start shows the code, and the saved
# text goes on the DEBUG line beside it. Old and new files look the same,
# because the saved reason's format did not change and it opens with its code.
_OLD = {
"sign": "SIGN_DISAGREEMENT: commanded -1000 W against a meter reading "
"+1500 W for 180 s continuously (limits: both over 300 W, held "
"over 180 s)",
"delivery": "UNIT_NOT_DELIVERING: inverter-a is standing at +2000 W and "
"delivering +0 W - 2000 W of its share (100 % of it) is not "
"arriving - while inverter-b is not in that state. Nothing "
"this add-on reads explains it - held for 121 s continuously "
"(limit: over 120 s)",
"circ": "CIRCULATING_POWER: 5800 W measured going round between the "
"inverters for 61 s, peaking at 6000 W, over the limits of 250 W "
"and 60 s. The meter cannot see it, because it nets to zero there",
}
class _OldStore(_S):
data = {"unit/inverter-a/sign_tripped": True,
"unit/inverter-a/sign_reason": _OLD["sign"],
"unit/inverter-a/delivery_tripped": True,
"unit/inverter-a/delivery_reason": _OLD["delivery"],
"circ_tripped": True, "circ_reason": _OLD["circ"],
"site_sign_tripped": True, "site_sign_reason": ""}
_restart = []
_rs = _captured("goodwe", lambda: _restart.append(Controller(
{"setpoint_entity": "number.sp", "meter_source": "off", "max_w": 2000},
_H(), _OldStore(), _P(), stop=asyncio.Event())))
_rs_err = [r.getMessage() for r in _rs if r.levelno == logging.ERROR]
_rs_dbg = [r.getMessage() for r in _rs if r.levelno == logging.DEBUG]
for _m in _rs_err:
print(f" {_m!r} ({len(words(_m))} words)")
check("an old state file's long reasons load unchanged, so the stops stay on",
_restart and _restart[0].inverters[0].sign_wd.tripped
and _restart[0].inverters[0].sign_wd.reason == _OLD["sign"]
and _restart[0].inverters[0].delivery_wd.reason == _OLD["delivery"]
and _restart[0].circ_wd.reason == _OLD["circ"])
check("...each ERROR line at start is one plain sentence with the code, at "
f"most {LINE_WORDS} words, and a stop saved without a reason says so",
len(_rs_err) == 4
and all(len(words(m)) <= LINE_WORDS and "(limits" not in m
for m in _rs_err)
and any(m.endswith(": SIGN_DISAGREEMENT.") for m in _rs_err)
and any(m.endswith(": UNIT_NOT_DELIVERING.") for m in _rs_err)
and any(m.endswith(": CIRCULATING_POWER.") for m in _rs_err)
and any(m.endswith(f": {messages.NO_REASON_SAVED}.") for m in _rs_err))
check("...and the saved text, figures and all, is on a DEBUG line beside it",
all(any(t in m for m in _rs_dbg) for t in _OLD.values()))
# UX-11 review: `log_level` defaults to info and `events` starts empty, so the
# saved figures also go on the action log, where `status` shows them.
_rs_ev = _restart[0].events if _restart else []
check(f"...and in the action log, which an installer reads at the default "
f"log level ({len(_rs_ev)} events)",
all(any(t in e for e in _rs_ev) for t in _OLD.values())
and any(e.endswith(messages.NO_REASON_SAVED) for e in _rs_ev))
# UX-11 item 4: the action log's clamp count and the shadow-off entry.
_main_src = (APP / "main.py").read_text(encoding="utf-8")
check("the action log counts 'engagements' with a real plural and the "
"shadow-off entry is plain, not 'engagement(s)' or 'SHADOW MODE OFF -'",
"engagement(s)" not in _main_src and "SHADOW MODE OFF" not in _main_src
and messages.count(25, "engagement") == "25 engagements"
and messages.count(1, "engagement") == "1 engagement")
print()
if fails:
print(f"{len(fails)} FAILED")
+7 -3
View File
@@ -4412,12 +4412,16 @@ check(f"AC, AND THE WHOLE OF DEFECT 4: 'trading is off' and 'trading is on "
f"`off (arbitrage_enabled)` for both - naming an option that is `true` "
f"in the options blob",
_T11_OFF[0]["Arbitrage"] != _T11_ON_HELD[0]["Arbitrage"])
# ⚠️ THE "Why" ROW OF THE SAME RENDER, NOT A SECOND READ OF `why_words`. Since
# UX-10 the waiting sentence counts its seconds when it is read, so reading the
# property again here, after the other renders above, could cross a second
# ("1 second" in the row, "2 seconds" now) - CI run 953 on PR #141 did.
check(f"...and the armed-but-held row carries the CONTROL LOOP'S OWN REASON "
f"({_T11_ON_HELD[1].why_words!r}), so the operator is told which input is "
f"({_T11_ON_HELD[0]['Why']!r}), so the operator is told which input is "
f"missing rather than being sent to look at a switch that is already on. "
f"The reason comes from main.py, not from this file",
_T11_ON_HELD[1].why_words
and _T11_ON_HELD[1].why_words in _T11_ON_HELD[0]["Arbitrage"])
_T11_ON_HELD[0]["Why"].startswith("A reading is missing")
and _T11_ON_HELD[0]["Why"] in _T11_ON_HELD[0]["Arbitrage"])
check(f"...and a cycle that DID reach the step renders the strategy's own "
f"sentence - {_T11_ON_OK[1].arb.explain()[:50]!r} - rather than a "
f"re-derivation of it, which is the guarantee OPT-04 put on this row and "
+15 -7
View File
@@ -697,13 +697,21 @@ print(f" {len(APP)} modules under app/; TEL-11 material is in: {_touch}")
check(f"PRECONDITION: the scan found the whole package, not a subset - "
f"{len(APP)} modules", len(APP) >= 25 and "control.py" in
[f.name for f in APP])
check("⭐ EXACTLY THREE MODULES CAN SEE THE MATERIAL: `pv.py` (the reader), "
"`main.py` (the read and the two operator surfaces) and `mqtt.py` (the "
"publication). `control.py`, `arbiter.py`, `allocator.py`, `peakguard.py`, "
"`arbitrage.py`, `maintenance.py`, `clamp.py`, `freeze.py`, "
"`watchdog.py`, `delivery.py` and `circulation.py` do not mention it in "
"any spelling, comments included",
_touch == ["main.py", "mqtt.py", "pv.py"])
# UX-13 adds the settings surface: labels (messages.py), a settings warning
# (validate.py) and the page's layout and derivation (uilayout.py, uimodel.py).
# None of them decides anything, so the decision modules stay excluded.
_DECIDERS = ("control.py", "arbiter.py", "allocator.py", "peakguard.py",
"arbitrage.py", "maintenance.py", "clamp.py", "freeze.py",
"watchdog.py", "delivery.py", "circulation.py")
check("⭐ ONLY THE READER, THE PUBLISHER AND THE SETTINGS SURFACE SEE THE "
"MATERIAL: `pv.py` (the reader), `main.py` (the read and the two operator "
"surfaces), `mqtt.py` (the publication), and `messages.py`, "
"`validate.py`, `uilayout.py` and `uimodel.py` (settings). "
f"{', '.join(_DECIDERS)} do not mention it in any spelling, comments "
"included",
_touch == ["main.py", "messages.py", "mqtt.py", "pv.py", "uilayout.py",
"uimodel.py", "validate.py"]
and not set(_DECIDERS) & set(_touch))
# habit 4 in the instrument: a scanner that cannot go red is not a scanner.
check("...and the scan CAN go red - a module body with the material in it is "
"caught, so the green above is the tree speaking and not the scanner "
+475
View File
@@ -0,0 +1,475 @@
"""Runnable check for SAFETY-52. `python3 test_refusal.py`
A battery that refuses to give power (the BMS cut-out) used to leave the
command standing at its last ask for hours: +5000 W for 11.87 h on 2026-09-06,
+1940 W for 3 h 55 m on the bus on 2026-09-19. Now a refused direction is held
at 0 W, a 200 W probe asks every 15 minutes, and the refusal ends on charge, on
an answered probe, on stop/start and when another writer takes the wire.
DECISIONS/SAFETY-52 has the record and the replay figures.
Mutating the modules this file grades? Purge `__pycache__` first, or run
`tools/mutation_run.sh`, which does - see MUTATION.md.
Parts 1-5 drive the REAL `Controller` (read_inputs + cycle, the real
SAFETY-37/57 gate) against a scripted battery whose reading stands at exactly
-4 W for any request >= -4 W at the cut-out, and follows otherwise. Time is the
`now_mono` handed to `read_inputs()`, so 12 hours run in seconds. `OLD` runs the
same fixture with `refused=None` forced into `compute()` - release/1.0's law -
so every "new" figure is shown beside the one it replaces. Part 4 also runs
`compute()` alone, as the bus saw 09-19 before the gate existed.
Mutations, each on a copy of this tree purged of `__pycache__`, graded with
`python3 -B` over test_refusal, test_control, test_clamp, test_telemetry and
test_messages (MUTATION.md). Reds are failing checks, on this tree:
# mutation reds
-- ------------------------------------------------------- ---------------
R1 control.py: the engage `if` -> `if False and ...` 8 here + 1 clamp
(release/1.0's behaviour)
R2 control.py: the exit on the other direction removed 1
R3 control.py: the exit on an answered probe removed 2
R4 control.py: `PROBE_W = 300.0`, above the gate's 250 W 4
R5 control.py: the hold keeps the old target, not 0 W 4
R6 main.py: `_refusal_from_stale()` returns at once 1
R7 main.py: another writer no longer ends the refusal 1
R8 main.py: stop/start no longer ends the refusal 1
R9 main.py: the probe window never opens 4
R10 main.py: seed from a stale stop below `saturation_w` again, 1
not below REFUSED_BELOW_W (review of #141). The same mutation
in control.py's engage clause SURVIVES, and that is expected:
the delivery exit (R11) ends such a refusal in the same cycle.
R11 control.py: only an answered PROBE ends the refusal 2
(`and probe` back in the delivery exit; review of #141)
"""
import asyncio
import sys
from datetime import datetime, timedelta, timezone
from app import control, freshness
from app.control import PROBE_EVERY_S, PROBE_S, PROBE_W, REFUSED, PROBING
from app.main import Controller, why_key
from app.arbiter import Claim
from app import messages
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
LIVE = {"max_w": 5000.0, "gain": 0.6, "slew_w": 400.0, "target_grid_w": -10.0,
"deadband_w": 15, "step_w": 10}
TICK = 5.0 # the meter's measured median tick (replay_recorded_loop)
CUT_W = -4.0 # what the register reads at the cut-out, 2026-09-06
H = 3600.0
BASE = datetime(2026, 9, 6, 19, 30, tzinfo=timezone.utc)
class _Store:
def __init__(self):
self.data = {}
def set(self, *a):
pass
def get_time(self, *a):
return None
class _Pub:
enabled = False
def publish(self, values):
pass
def close(self):
pass
class _Hass:
"""House load, and a battery that follows unless `cut(t)` says it refuses.
At the cut-out the reading is exactly CUT_W for any request >= CUT_W (a flat
register, which is what arms or does not arm the stale-reading gate). A
charge request is followed: the pack accepts charge at the floor.
`cap(t)` limits discharge while not cut (the 09-06 pack gave 4570 W at 10 %).
"""
def __init__(self, load, cut, cap=lambda t: 1e9):
self.load, self.cut, self.cap = load, cut, cap
self.t = 0.0
self.cmd = 0.0
self.writes = []
def batt(self):
if self.cut(self.t) and self.cmd >= CUT_W:
return CUT_W
return float(round(min(self.cmd, self.cap(self.t))))
async def limits(self, entity):
return (-LIVE["max_w"], LIVE["max_w"], 1.0)
async def number(self, entity, invert=False):
b = self.batt()
return {"sensor.grid": self.load(self.t) - b, "sensor.soc": 9.0,
"sensor.batt": b}.get(entity)
async def set_number(self, entity, value):
self.writes.append((self.t, float(value)))
self.cmd = float(value)
return True
async def call(self, *a):
return True
def run(load, cut, dur, cap=lambda t: 1e9, old=False, events=None):
"""Real cycles every TICK seconds of `now_mono`. `events[t] = fn(c)` pokes
the controller (stop, start, another writer) at that instant.
Returns [(t, grid, batt, setpoint, i_w, loop_reason, batt_refused)], the
number of gate trips, and the controller."""
async def go():
hass = _Hass(load, cut, cap)
c = Controller(dict(
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "heartbeat_s": 10, "stale_input_s": 15},
**LIVE), hass, _Store(), _Pub(), stop=asyncio.Event())
c.auto = True
c.dev_min, c.dev_max = -LIVE["max_w"], LIVE["max_w"]
import app.main as m
real, real_dt = m.compute, m.datetime
clock = [0.0]
class _DT(real_dt):
"""`cycle()`'s wall clock follows `now_mono`, so the 15 s input hold
and the gate's release run in simulated seconds too."""
@classmethod
def now(cls, tz=None):
return BASE + timedelta(seconds=clock[0])
m.datetime = _DT
if old:
m.compute = lambda *a, **k: real(*a, **dict(k, refused=None))
rows, trips, was = [], 0, False
try:
t = 0.0
while t < dur:
hass.t = clock[0] = t
for et, fn in list((events or {}).items()):
if et <= t:
fn(c)
del events[et]
await c.read_inputs(now_mono=t)
stale = c.inverters[0].batt_fresh.stale
trips += stale and not was
was = stale
await c.cycle()
rows.append((t, hass.load(t) - hass.batt(), hass.batt(),
hass.cmd, c.i_w, c.loop_reason, c.batt_refused))
t += TICK
finally:
m.compute, m.datetime = real, real_dt
return rows, trips, c
return asyncio.run(go())
def at(rows, t):
return min(rows, key=lambda r: abs(r[0] - t))
def longest_hold_h(rows, floor_w=250.0, until=None):
"""Longest run of one identical request at or above `floor_w`, in hours."""
best = cur = 0.0
last = None
for r in rows:
if until is not None and r[0] >= until:
break
cur = cur + TICK if (r[3] == last and abs(r[3]) >= floor_w) else 0.0
last = r[3]
best = max(best, cur)
return best / H
# ==============================================================================
print("1. the 09-06 shape: a load step takes the request to 5000 W, the battery "
"cuts out, the load ends")
# ==============================================================================
def load906(t):
return 1020 if t < 60 else 4800 if t < 162 else 940 if t < 11.9 * H else -600
def cut906(t):
return t >= 132
def cap906(t):
return 4570.0
old906, otrips906, _ = run(load906, cut906, 12.2 * H, cap906, old=True)
new906, ntrips906, c906 = run(load906, cut906, 12.2 * H, cap906)
for name, rows, tr in (("old", old906, otrips906), ("new", new906, ntrips906)):
print(f" {name}: request at 2 min {at(rows, 120)[3]:+.0f} W, at 6 h "
f"{at(rows, 6 * H)[3]:+.0f} W (i_w {at(rows, 6 * H)[4]:+.0f}), longest "
f"hold {longest_hold_h(rows):.2f} h, gate trips {tr}")
check("PRECONDITION: the old law holds +5000 W for the whole night on this "
"fixture, as it did on 2026-09-06 - the fixture reproduces the card",
at(old906, 6 * H)[3] == 5000.0 and longest_hold_h(old906) > 11.5)
check("the request reaches the rail before the cut, so the new law starts from "
"the same place", at(new906, 120)[3] == 5000.0)
t0 = next((r[0] for r in new906 if r[5] == REFUSED), None)
check(f"after the cut the battery-refuses hold takes the request to 0 W within "
f"about a minute (at t={t0})", t0 is not None and 132 < t0 <= 132 + 90
and at(new906, t0)[3] == 0.0)
check("...and it stays refused overnight, with the integrator at 0, and no "
"request of 250 W or more stands for longer than one probe interval",
at(new906, 6 * H)[6] == 1 and at(new906, 6 * H)[4] == 0.0
and longest_hold_h(new906, until=11.9 * H) < PROBE_EVERY_S / H)
check(f"...and the stale-reading gate does not cycle: {ntrips906} trips in "
f"12 hours (the old law's latch also kept it quiet: {otrips906})",
ntrips906 == 0)
morning = [r for r in new906 if r[0] >= 11.9 * H + 60]
check("when solar makes the grid export, the refusal ends and the battery "
"charges - the exit on the other direction",
morning and morning[-1][6] == 0 and morning[-1][3] < -400)
# ==============================================================================
print("2. the probe: 200 W every 15 minutes, below the gate's 250 W")
# ==============================================================================
probes = []
for r in new906:
if r[3] == PROBE_W and (not probes or r[0] - probes[-1][1] > TICK):
probes.append([r[0], r[0]])
elif r[3] == PROBE_W:
probes[-1][1] = r[0]
starts = [p[0] for p in probes]
gaps = [b - a for a, b in zip(starts, starts[1:])]
print(f" {len(probes)} probes, first at {starts[0] / 60 if starts else 0:.1f} "
f"min, gaps {sorted(set(round(g) for g in gaps))} s, lengths "
f"{sorted(set(round(p[1] - p[0] + TICK) for p in probes))} s")
check("the probe asks exactly PROBE_W, which is below the stale-reading gate's "
"threshold, so a probe can never arm it",
PROBE_W < freshness.MOVE_W and all(r[3] in (0.0, PROBE_W)
for r in new906 if r[6] == 1))
check("there is a probe every 15 minutes through the night (at least 40 in "
"11.8 hours), each about 34 s long",
len(probes) >= 40 and all(PROBE_EVERY_S <= g <= PROBE_EVERY_S + PROBE_S
+ 2 * TICK for g in gaps)
and all(PROBE_S - TICK <= p[1] - p[0] + TICK <= PROBE_S + TICK
for p in probes))
check("...and a probe reads as a probe on the loop's own reason row",
any(r[5] == PROBING for r in new906))
# ==============================================================================
print("3. recovery with no sign change: the battery gives power again at 2 h")
# ==============================================================================
def cut_rec(t):
return 132 <= t < 2 * H
oldr, _, _ = run(load906, cut_rec, 2.6 * H, cap906, old=True)
newr, _, crec = run(load906, cut_rec, 2.6 * H, cap906)
after_o = [r for r in oldr if 2 * H <= r[0] < 2 * H + 600]
after_n = [r for r in newr if 2 * H <= r[0] < 2.6 * H]
exp_o = sum(max(0.0, -r[1]) * TICK for r in after_o) / 3600
exp_n = sum(max(0.0, -r[1]) * TICK for r in after_n) / 3600
print(f" old: worst grid {min(r[1] for r in after_o):+.0f} W, export "
f"{exp_o:.0f} Wh; new: worst grid {min(r[1] for r in after_n):+.0f} W, "
f"export {exp_n:.0f} Wh")
check("PRECONDITION: the old law answers a recovering battery with its "
"standing +5000 W and exports kilowatts into a 940 W house",
min(r[1] for r in after_o) < -3000)
check("the new law never exports more than the probe while it waits, and the "
"answered probe ends the refusal so control resumes",
min(r[1] for r in after_n) > -PROBE_W - 50
and after_n[-1][6] == 0 and abs(after_n[-1][1] - (-10)) < 100)
check("...and the event log says the probe was answered",
any("BATTERY REFUSES ENDED: the probe was answered" in e
for e in crec.events))
# ==============================================================================
print("4. the 09-19 shape: a stale-reading stop on a frozen ~0 W reading "
"is a refusal")
# ==============================================================================
# The request steps +1540 -> +1940 and more as the battery cuts out mid-ramp:
# the request moves after the reading went flat, so the gate trips before the
# hold's 12 cycles - the ~70 s cycle SAFETY-59 measured. The trip seeds the hold.
def load919(t):
return 1530 if t < 60 else 2400 if t < 1800 else 900 if t < 4 * H else -600
def cut919(t):
return t >= 65
def run919(old):
return run(load919, cut919, 4.2 * H, old=old)
old919, otr919, _ = run919(True)
new919, ntr919, c919 = run919(False)
print(f" old: gate trips {otr919}, longest hold {longest_hold_h(old919):.2f} h;"
f" new: gate trips {ntr919}, longest hold {longest_hold_h(new919):.2f} h")
check("PRECONDITION: on the old law the gate trips over and over all night "
"(the SAFETY-59 cycle) or the request stands for hours",
otr919 > 20 or longest_hold_h(old919) > 1.0)
check("the new law stops after at most two trips and holds 0 W, and the event "
"log says the battery refuses",
ntr919 <= 2 and at(new919, 2 * H)[3] in (0.0, PROBE_W)
and any("BATTERY REFUSES" in e for e in c919.events))
# The same shape through `compute()` alone, as the bus saw it on 2026-09-19
# before the gate existed: +1540 -> +1940, then a battery giving nothing.
T = control.Tuning(**LIVE)
res = {}
for name, carry in (("old", None), ("new", 0)):
# sat_count 2: the +1540 and +1940 cycles were already short (the plan)
prev, i_w, sat, ref, cmds = 1940.0, 2340.0, 2, carry, []
for _ in range(2000): # ~2.8 h at 5 s
d = control.compute(prev, 1950.0, CUT_W, T, sat, i_w, refused=ref)
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
cmds.append(prev)
res[name] = cmds
print(f" compute() alone: old stands at {res['old'][-1]:+.0f} W "
f"({sum(v == 1940.0 for v in res['old'])} of 2000 cycles at +1940 W), "
f"new at {res['new'][-1]:+.0f} W from cycle "
f"{res['new'].index(0.0) if 0.0 in res['new'] else None}")
check("PRECONDITION: without the gate the old law parks at +1940 W, the 7 065 "
"identical writes the bus recorded", set(res["old"]) == {1940.0})
check("...and the new law holds 0 W within SETTLE_CYCLES cycles",
res["new"].index(0.0) < control.SETTLE_CYCLES
and set(res["new"][control.SETTLE_CYCLES:]) == {0.0})
# ==============================================================================
print("5. the other exits: stop, start, another writer")
# ==============================================================================
def stop(c):
c.auto = False
def start(c):
c.auto = True
rows, _, c = run(load906, cut906, 1200, cap906, events={600.0: stop,
700.0: start})
check("stopping control ends the refusal, and starting again begins from "
"nothing refused", at(rows, 590)[6] == 1 and at(rows, 650)[6] == 0
and at(rows, 705)[6] == 0)
def other_writer(c):
c.loop_w = 1234.0 # the arbiter gave the wire something the loop did not ask
rows, _, c = run(load906, cut906, 900, cap906, events={600.0: other_writer})
check("another writer on the wire ends the refusal (the arbiter reseed)",
at(rows, 590)[6] == 1 and at(rows, 605)[6] == 0)
# ==============================================================================
print("5b. review of #141: a pack that gives SOME power, and a reading that is "
"only late, are not a refusal")
# ==============================================================================
# A pack derated to 100-499 W (cold, BMS taper) gives what it can against a
# larger ask. Engaging below `saturation_w` (500 W) held it at 0 W for ~93 % of
# the time; "gives nothing" is below the probe's own answer.
# `compute()` alone: through the Controller the stale-reading gate trips on the
# flat 300 W first, and that fixture then passes whatever this threshold is.
def derated(carry, cap_w=300.0, n=1800):
prev, i_w, sat, ref, gave, held = 0.0, 0.0, 0, carry, 0.0, 0
b = 0.0
for _ in range(n): # 2.5 h at 5 s
d = control.compute(prev, 2000.0 - b, b, T, sat, i_w, refused=ref)
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
held += bool(ref)
b = max(0.0, min(prev, cap_w)) # one tick late
gave += b
return gave / n, held
T = control.Tuning(**LIVE)
gave_old, _ = derated(None)
gave_new, held_new = derated(0)
print(f" pack derated to 300 W: old law {gave_old:.0f} W average, new "
f"{gave_new:.0f} W, held as refusing on {held_new} cycles")
check("a pack that gives a steady 300 W against a 2000 W ask is never held at "
"0 W as refusing, and keeps giving what the old law got from it",
held_new == 0 and gave_new == gave_old and gave_old > 290.0)
def lagging(tick, dead_s=6.0, publish_s=10.0, phase_s=5.0, dur=600.0):
"""`compute()` on a HEALTHY pack whose reading lags: it follows the command
of `dead_s` ago, published every `publish_s`. A 1 s meter (`meter_poll_s`
1) makes SETTLE_CYCLES only 12 s, shorter than that lag."""
prev, i_w, sat, ref, hist, reg, pub = 0.0, 0.0, 0, 0, [], 0.0, -phase_s
held = engaged = 0
t = 0.0
while t < dur:
then = [c for tc, c in hist if tc <= t - dead_s]
b = then[-1] if then else 0.0
if t - pub >= publish_s:
reg, pub = b, t
d = control.compute(prev, (3000.0 if t >= 10 else 0.0) - b, reg, T,
sat, i_w, refused=ref)
engaged += bool(d.refused) and not ref
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
hist.append((t, prev))
held += tick * bool(ref)
t += tick
return engaged, held
lag1 = lagging(1.0)
print(f" 1 s meter, healthy pack with a late reading: engaged {lag1[0]} "
f"time(s), held {lag1[1]:.0f} s")
check("a healthy pack whose reading is merely late is let go as soon as the "
"reading shows it delivering - not held until the next probe",
lag1[1] <= 10.0)
async def _seed(held_w):
"""`_refusal_from_stale()` on a unit standing at +2000 W, frozen."""
c = Controller(dict(
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off"}, **LIVE),
_Hass(lambda t: 0.0, lambda t: False), _Store(), _Pub(),
stop=asyncio.Event())
c.auto, c.sat_count = True, c.tuning.saturation_cycles
inv = c.inverters[0]
inv.last_write, inv.batt_fresh.held = 2000.0, held_w
c._refusal_from_stale(inv, 100.0)
return c.batt_refused
check("a stale-reading stop on a register standing at 300 W is not a refusal "
"(it gives something), and one at -4 W is",
asyncio.run(_seed(300.0)) == 0 and asyncio.run(_seed(CUT_W)) == 1)
d = control.compute(0.0, 1500.0, 1400.0, T, 0, 0.0, refused=1, probe=False)
check("...i.e. a held direction that reads 100 W or more ends the refusal "
"without waiting for a probe", d.refused == 0)
# ==============================================================================
print("6. words")
# ==============================================================================
w = messages.why(why_key("loop", [Claim.set("loop", 0, 0.0, REFUSED)]), 0.0)
wp = messages.why(why_key("loop", [Claim.set("loop", 0, PROBE_W, PROBING)]),
PROBE_W)
print(f" {w!r} / {wp!r}")
check("the page's Why line says the battery refuses, not 'Keeping the grid "
"near zero: 0 W'", w == "The battery refuses to give power: 0 W")
check("...and a probe says what it is", wp.startswith("Testing if the battery"))
check("...and an ordinary loop cycle still reads as the loop",
why_key("loop", [Claim.set("loop", 0, 10.0, "tracking")]) == "loop")
print()
if fails:
print(f"{len(fails)} FAILED: " + ", ".join(fails))
sys.exit(1)
print("all checks passed")
+20 -5
View File
@@ -636,12 +636,18 @@ _app = web.build_app(FakeController(), FakeSupervisor())
_routes = sorted({(r.method, r.get_info().get("path"))
for r in _app.router.routes() if r.method != "HEAD"})
print(" " + " ".join(f"{m} {p}" for m, p in _routes))
check("the configuration surface adds five routes and touches none of the "
"three that were there",
check("the configuration surface adds five routes and UX-13 one GET, and "
"none touches the three that were there",
_routes == [("GET", "/"), ("GET", "/config"), ("GET", "/config/model"),
("GET", "/status"), ("POST", "/action"),
("POST", "/config/restart"), ("POST", "/config/save"),
("POST", "/config/validate")])
("GET", "/ha/entities"), ("GET", "/status"),
("POST", "/action"), ("POST", "/config/restart"),
("POST", "/config/save"), ("POST", "/config/validate")])
_ents_src = io.open(os.path.join(HERE, "app", "haentities.py"),
encoding="utf-8").read()
check("UX-13's entity list only reads: haentities.py calls hass.states() and "
"no service, setter or action",
"hass.states()" in _ents_src
and not re.search(r"\.(call|set_number|handle_action|post)\(", _ents_src))
_selfconfig_src = io.open(os.path.join(HERE, "app", "selfconfig.py"),
encoding="utf-8").read()
for forbidden in ("set_number", "write_setpoint", "handle_action",
@@ -692,6 +698,10 @@ async def _e2e():
async with s.post(f"{root}/config/validate",
json={"options": base(setpoint_entity="")}) as r:
out["invalid"] = await r.json()
async with s.post(f"{root}/config/validate",
json={"options": base(integrator_max_w=3000)}
) as r:
out["warned"] = await r.json()
# ⚠️ THE COUNTS ARE SNAPSHOTTED AT EACH STAGE. Asserting
# `sup.writes == []` after the whole sequence would be asserting
# about the LAST request, not this one - the first draft did, and
@@ -749,6 +759,11 @@ check("...and it honours the browser's language per key, falling back to "
check("POST config/validate returns the validator's sentences, anchored",
E["invalid"]["problems"]
and "setpoint_entity" in E["invalid"]["by_key"])
check("UX-13: POST config/validate also returns the validator's warnings, "
"beside no refusal",
E["warned"]["problems"] == [] and [n["keys"] for n in
E["warned"]["notes"]]
== [["integrator_max_w"]] and E["warned"]["notes"][0]["tier"] == "warn")
check("a save of an invalid blob answers 422 and the Supervisor got nothing",
E["save_invalid"][0] == 422
and E["save_invalid"][1]["kind"] == "invalid"
+202
View File
@@ -0,0 +1,202 @@
"""UX-13 P0: the layout table places every option once. `python3 test_uilayout.py`
app/uilayout.py is the one place UI code names an option key
(DECISIONS/UX-13-one-layout-table.md). This file fails CI when config.yaml
gains an option the table does not place, and checks each row against the
sources UX-02 keeps authoritative: config.yaml for ranges, translations and
app/ui_text for words, validate.py for which entities are read as watts.
Mutating a module this file grades? Read MUTATION.md first (purge __pycache__).
"""
import io
import json
import os
import re
import sys
HERE = os.path.dirname(os.path.abspath(__file__))
sys.path.insert(0, os.path.join(HERE, "tools"))
import translations_lint as TL # noqa: E402
from app import uilayout as L, uimodel, validate # noqa: E402
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
CONFIG = io.open(os.path.join(HERE, "config.yaml"), encoding="utf-8").read()
ORDER, NESTED = TL.config_surface(CONFIG)
TYPES = dict(re.findall(r"^ ([a-z_0-9]+): *(\S.*?) *$",
CONFIG[CONFIG.index("\nschema:"):], re.M))
EN = TL.parse_translation_file(os.path.join(HERE, "translations", "en.yaml"))
UI_TEXT = json.load(io.open(os.path.join(HERE, "app", "ui_text", "en.json"),
encoding="utf-8"))
ROWS = list(L.fields())
KEYS = [f.key for _g, _p, f in ROWS]
def coverage_problems(order, nested):
"""Every way the table and config.yaml's schema disagree."""
out = []
placed = [k for k in KEYS if not k.startswith(("ui.", "inverters."))]
for k in order:
n = placed.count(k) + (k in L.DERIVED) + (k in L.HIDDEN)
if n != 1:
out.append(f"{k} is placed {n} times")
out += [f"{k} is not in config.yaml" for k in
set(placed) | set(L.DERIVED) | set(L.HIDDEN) if k not in order]
sub = [k.split(".", 1)[1] for k in KEYS if k.startswith("inverters.")]
out += [f"inverters.{k} has no card field" for k in nested.get("inverters", [])
if sub.count(k) != 1]
out += [f"inverters.{k} is not in config.yaml" for k in sub
if k not in nested.get("inverters", [])]
return out
print("1. every option has exactly one place")
_p = coverage_problems(ORDER, NESTED)
_fields = sum(1 for k in ORDER if k in KEYS)
print(f" {len(ORDER)} options: {_fields} fields, {len(L.DERIVED)} derived, "
f"{len(L.HIDDEN)} hidden. Problems: {_p}")
check(f"config.yaml's {len(ORDER)} options are each a field, derived or hidden, "
"once", not _p and len(ORDER) >= 78)
check("a new option without a place fails this check",
coverage_problems(ORDER + ["new_option_w"], NESTED)
== ["new_option_w is placed 0 times"])
check("...and so does a new inverter field",
coverage_problems(ORDER, {"inverters": NESTED["inverters"] + ["mode"]})
== ["inverters.mode has no card field"])
check("no key is both a field and derived",
not set(KEYS) & (set(L.DERIVED) | set(L.HIDDEN)))
check("each derived key names the page field that writes it",
all(any(f.key == how for _g, _p2, f in ROWS)
for how in L.DERIVED.values()))
print("\n2. each row is well formed")
check("every control, entity kind and show operator is a known one",
all(f.control in L.CONTROLS and (not f.kind or f.kind in L.ENTITY_KINDS)
and all(op in L.SHOW_OPS for _n, op, _v in f.show)
for _g, _p2, f in ROWS))
_names = set(ORDER) | set(KEYS) | {"inverter_count"}
check("every show condition reads an option, a page field or inverter_count",
all(n in _names for _g, _p2, f in ROWS for n, _o, _v in f.show))
check("every entity control has a kind, and no other control has one",
all((f.control in (L.ENTITY, L.ENTITY_LIST, L.SOLAR_LIST)) == bool(f.kind)
for _g, _p2, f in ROWS))
check("everything applies after a restart: options are read at start, and "
"OPT-11's runtime switches are not built yet",
all(f.applies == L.RESTART for _g, _p2, f in ROWS))
check("no unit states a number, so no range is written here",
all(not re.search(r"\d", f.unit) for _g, _p2, f in ROWS))
_SCHEMA = CONFIG[CONFIG.index("\nschema:"):]
_ROSTER = re.search(r"^ inverters:\n((?: {4,}.*\n)+)", _SCHEMA, re.M).group(1)
ROSTER_TYPES = dict(re.findall(r"^ {4,}(?:- )?([a-z_0-9]+): *(\S+)", _ROSTER,
re.M))
def _type(key):
if key.startswith("inverters."):
return ROSTER_TYPES.get(key.split(".", 1)[1], "")
return TYPES.get(key, "")
_ranged = [f.key for _g, _p2, f in ROWS
if f.control in (L.SLIDER, L.NUMBER, L.LOCKED)
and not f.key.startswith("ui.")]
_unranged = [k for k in _ranged if not re.match(r"(int|float)\(", _type(k))]
check(f"every slider, number and locked value has a range in config.yaml "
f"({len(_ranged)} of them, without: {_unranged})", not _unranged)
_SUFFIX = (("_eur_kwh", "€/kWh"), ("_eur", "€/kWh"), ("_kwh", "kWh"),
("_w", "W"), ("_s", "s"), ("_h", "h"), ("_min", "min"),
("_days", "days"), ("_floor", "%"), ("_ceiling", "%"),
("_target", "%"))
def _unit_problem(f):
want = next((u for suf, u in _SUFFIX if f.key.endswith(suf)), None)
if want is None or f.control not in (L.SLIDER, L.NUMBER, L.LOCKED):
return False
return f.unit != want and not (want == "W" and f.unit == "kW"
and f.scale == 1000)
_mism = [(f.key, f.unit) for _g, _p2, f in ROWS if _unit_problem(f)]
check(f"each unit matches its key's suffix (mismatched: {_mism})", not _mism)
check("the peak limit is shown in kW and stored in W",
L.field("peak_cap_w").unit == "kW" and L.field("peak_cap_w").scale == 1000)
_watt = sorted({f.key.split(".")[-1] for _g, _p2, f in ROWS
if f.kind == "power_w"})
check(f"the pickers that expect watts are exactly the entities validate.py "
f"reads as watts ({_watt})",
_watt == sorted(validate.WATT_ENTITY_KEYS))
check("range_of() reads a Supervisor-shaped schema, nested ones too",
L.range_of("max_w", [{"name": "max_w", "lengthMin": 100,
"lengthMax": 5000}]) == (100, 5000)
and L.range_of("inverters.max_w", [{"name": "inverters", "schema": [
{"name": "max_w", "lengthMin": 100, "lengthMax": 5000}]}])
== (100, 5000)
and L.range_of("p1_host", [{"name": "p1_host"}]) is None)
print("\n3. the words come from translations and app/ui_text")
_conf = EN["configuration"]
_no_tr = [k for k in KEYS if not k.startswith("ui.") and not (
k in _conf if "." not in k
else k.split(".")[1] in _conf["inverters"]["fields"])]
check(f"every option field has an en.yaml name (missing: {_no_tr})", not _no_tr)
_no_ui = [k for k in KEYS if k.startswith("ui.")
and k[3:] not in UI_TEXT["fields"]]
check(f"every page-only field has words in ui_text (missing: {_no_ui})",
not _no_ui)
_titles = [g.id for g in L.GROUPS if g.id not in UI_TEXT["groups"]] + [
f"{g.id}.{p.id}" for g in L.GROUPS for p in g.parts
if p.id and f"{g.id}.{p.id}" not in UI_TEXT["parts"]]
check(f"every group and part has a title (missing: {_titles})", not _titles)
_contract = {"none", "fixed", "daynight", "dynamic", "custom"}
check("every contract, fallback and region the model can hold has words",
set(UI_TEXT["choices"]["contract"]) == _contract
and set(UI_TEXT["choices"]["fallback"]) == _contract - {"dynamic"}
and set(UI_TEXT["choices"]["region"])
== set(uimodel.REGION_PRESETS) | {uimodel.OWN})
check("both 'applies' labels have words",
set(UI_TEXT["applies"]) == {L.RESTART, L.NOW})
print("\n4. visibility follows the page model")
_m = uimodel.options_to_ui({"meter_source": "ha_signed", "meter_phases": 3,
"inverters": [], "maintenance_enabled": False})
check("a signed meter shows its net entity, and three phases its net list",
L.visible(L.field("p1_net_entity"), _m)
and L.visible(L.field("p1_phase_net_entities"), _m)
and not L.visible(L.field("meter_entity"), _m)
and not L.visible(L.field("p1_phase_import_entities"), _m))
check("one inverter shows the one-inverter stops, not the per-inverter ones",
L.visible(L.field("sign_disagree_w"), _m)
and not L.visible(L.field("unit_sign_disagree_w"), _m))
check("maintenance details hide while maintenance is off",
not L.visible(L.field("maintenance_charge_w"), _m))
print("\n5. UI code names option keys in two files only")
_KEY = re.compile(r"""["']([a-z0-9]+(?:_[a-z0-9]+)+)["']""")
_src = io.open(os.path.join(HERE, "app", "uimodel.py"), encoding="utf-8").read()
_owned = set(L.DERIVED) | {"inverters", "price_provider",
"price_taxes_eur_kwh", "arbitrage_enabled"}
_extra = sorted({k for k in _KEY.findall(_src) if k in ORDER} - _owned)
check(f"uimodel.py names only the keys its derivations write (others: "
f"{_extra})", not _extra)
_leak = sorted({f"{name}:{k}" for name in ("haentities.py", "web.py")
for k in _KEY.findall(io.open(os.path.join(HERE, "app", name),
encoding="utf-8").read())
if k in ORDER})
check(f"haentities.py and web.py name no option key ({_leak})", not _leak)
print()
if fails:
print(f"{len(fails)} FAILED")
sys.exit(1)
print("all passed")
+224
View File
@@ -0,0 +1,224 @@
"""UX-13 P0: stored options <-> page model, exactly. `python3 test_uimodel.py`
app/uimodel.py derives the keys the page does not show (the flat inverter,
the solar keys, static_profile, the levies figure, arbitrage_enabled). Part 1
round-trips every options blob the test suite hands the validator
(scenarios/ux13/, recorded by tools/ux13_validator_calls.py at 652097a), the
TEST-23 option files and config.yaml's defaults: options -> model -> JSON ->
options must be identical. Parts 2-6 edit one page field and check the blob.
Mutating a module this file grades? Read MUTATION.md first (purge __pycache__).
"""
import glob
import gzip
import io
import json
import logging
import os
import re
import sys
HERE = os.path.dirname(os.path.abspath(__file__))
logging.disable(logging.WARNING) # the validator's own log lines
from app import uimodel as U # noqa: E402
from app.price import (FLEMISH_TAXES_COMPONENTS_EUR_KWH, # noqa: E402
PRICE_OPTION_DEFAULTS)
from app.static_tariff import parse_static_profile # noqa: E402
from app.validate import validate_startup_config # noqa: E402
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def trip(options):
return U.ui_to_options(json.loads(json.dumps(U.options_to_ui(options))))
def edit(options, **fields):
model = json.loads(json.dumps(U.options_to_ui(options)))
for k, v in fields.items():
model[k.replace("__", ".")] = v
return U.ui_to_options(model)
def raises(fn):
try:
fn()
except U.DeriveError:
return True
return False
def defaults():
"""config.yaml's `options:` block, read without PyYAML (not in CI)."""
text = io.open(os.path.join(HERE, "config.yaml"), encoding="utf-8").read()
block = text[text.index("\noptions:"):text.index("\nschema:")]
out = {}
for key, raw in re.findall(r"^ ([a-z_0-9]+):(.*)$", block, re.M):
raw = raw.split(" #")[0].strip()
try:
out[key] = json.loads(raw)
except ValueError:
out[key] = raw
return out
DEFAULTS = defaults()
SITE = dict(DEFAULTS, setpoint_entity="number.goodwe_setpoint",
soc_entity="sensor.soc", batt_entity="sensor.batt")
print("1. every known blob survives the round trip unchanged")
_calls = [json.loads(line) for line in gzip.open(os.path.join(
HERE, "scenarios", "ux13", "validator-calls-652097a.jsonl.gz"), "rt")]
_test23 = sorted(glob.glob(os.path.join(HERE, "scenarios", "ux13", "test23",
"*.json")))
_blobs = ([("config.yaml", DEFAULTS)]
+ [(c["source"], c["opts"]) for c in _calls
if isinstance(c["opts"], dict)]
+ [(os.path.basename(f), json.load(open(f))) for f in _test23])
_bad = []
for _src, _o in _blobs:
try:
_back = trip(_o)
except Exception as e: # noqa: BLE001
_bad.append(f"{_src}: {type(e).__name__} {e}")
continue
if json.dumps(_back, sort_keys=True) != json.dumps(_o, sort_keys=True):
_bad.append(f"{_src}: {sorted(set(_back) ^ set(_o)) or 'values'}")
print(f" {len(_calls)} validator calls, {len(_test23)} TEST-23 files, "
f"config.yaml defaults")
check(f"all {len(_blobs)} are identical after options -> model -> JSON -> "
f"options (not: {_bad[:3]})", not _bad and len(_calls) >= 200
and len(_test23) >= 5 and len(DEFAULTS) >= 78)
check("config.yaml was read whole: the defaults hold every option",
"inverters" in DEFAULTS and DEFAULTS["inverters"] == []
and DEFAULTS["price_taxes_eur_kwh"] == 0.11736)
_m = U.options_to_ui(DEFAULTS)
check("the page model never shows a derived key: it keeps them aside",
not {"setpoint_entity", "pv_entity", "pv_entities", "static_profile",
"price_taxes_profile"} & set(_m)
and set(_m["keep"]) >= {"static_profile", "pv_entity", "max_w"})
check("a blob that lacks keys gains none", trip({"max_w": 900}) == {"max_w": 900})
print("\n2. one inverter or a list")
_one = edit(SITE, inverters=[dict(U.options_to_ui(SITE)["inverters"][0],
max_w=1500)])
check("editing the one inverter writes the flat keys and keeps the list empty",
_one["max_w"] == 1500 and _one["inverters"] == []
and _one["setpoint_entity"] == "number.goodwe_setpoint")
_card = U.options_to_ui(SITE)["inverters"][0]
_two = edit(SITE, inverters=[
dict(_card, name="inverter-a", capacity_kwh=None),
dict(_card, name="inverter-b", setpoint_entity="number.goodwe_b",
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b")])
check("a second inverter writes the list and clears the flat power request "
"entity, which the validator refuses beside a list",
len(_two["inverters"]) == 2 and _two["setpoint_entity"] == ""
and "capacity_kwh" not in _two["inverters"][0]
and not validate_startup_config(_two))
_listed = dict(SITE, setpoint_entity="", inverters=[
{"name": "garage", "setpoint_entity": "number.g", "max_w": 2000,
"bms_soc_floor": 10}])
_l1 = edit(_listed, inverters=[dict(_listed["inverters"][0], max_w=1800)])
check("a list of one stays a list, so the inverter keeps its name and stored "
"state", _l1["inverters"] == [dict(_listed["inverters"][0], max_w=1800)])
check("editing a listed inverter keeps the unread flat keys as stored",
all(_l1[k] == _listed[k] for k in ("setpoint_entity", "soc_entity",
"batt_entity", "max_w")))
check("a name on the flat inverter is refused rather than dropped",
raises(lambda: edit(SITE, inverters=[dict(_card, name="garage")])))
_raw = dict(SITE, inverters="garage")
check("a roster no card can show is kept when another field is saved, and "
"cannot be edited here",
edit(_raw, gain=0.5)["inverters"] == "garage"
and raises(lambda: edit(_raw, inverters=[_card])))
print("\n3. solar rows")
check("a stored flip reads as a reversed row",
U.options_to_ui(dict(DEFAULTS, pv_entity="sensor.pv",
pv_invert_entities=["sensor.pv"]))["ui.solar"]
== [{"entity": "sensor.pv", "reversed": True}])
check("one row writes pv_entity",
edit(DEFAULTS, ui__solar=[{"entity": "sensor.pv", "reversed": False}])
["pv_entity"] == "sensor.pv")
_pv2 = edit(dict(DEFAULTS, pv_entity="sensor.a"), ui__solar=[
{"entity": "sensor.a", "reversed": False},
{"entity": "sensor.b", "reversed": True}])
check("two rows write pv_entities, clear pv_entity and flip the reversed one",
_pv2["pv_entities"] == ["sensor.a", "sensor.b"] and _pv2["pv_entity"] == ""
and _pv2["pv_invert_entities"] == ["sensor.b"])
_stray = dict(DEFAULTS, pv_entities=["sensor.a", "sensor.b"],
pv_invert_entities=["sensor.b", "sensor.old"])
_pv1 = edit(_stray, ui__solar=[{"entity": "sensor.a", "reversed": False}])
check("removing a reversed row drops its flip, and a flip that was never a row "
"stays as stored", _pv1["pv_entities"] == ["sensor.a"]
and _pv1["pv_invert_entities"] == ["sensor.old"])
print("\n4. contract and prices")
_fixed = edit(DEFAULTS, ui__contract="fixed", ui__fixed_price=0.31)
check("a fixed price writes a profile the tariff parser reads as one price",
_fixed["price_provider"] == "off"
and [p.eur_per_kwh for p in parse_static_profile(
_fixed["static_profile"]).periods] == [0.31]
and U.options_to_ui(_fixed)["ui.contract"] == "fixed")
_dn = edit(SITE, ui__contract="daynight", ui__day_price=0.34,
ui__night_price=0.26)
check("day and night write a profile that starts and reads back the same",
not validate_startup_config(_dn)
and U.options_to_ui(_dn)["ui.day_price"] == 0.34
and U.options_to_ui(_dn)["ui.night_price"] == 0.26)
_dyn = edit(_dn, ui__contract="dynamic", price_provider="generic_dayahead")
check("a dynamic contract keeps the day and night profile as its fallback",
_dyn["price_provider"] == "generic_dayahead"
and _dyn["static_profile"] == _dn["static_profile"])
check("a dynamic contract without a price source is refused here",
raises(lambda: edit(DEFAULTS, ui__contract="dynamic")))
_odd = json.dumps({"periods": [
{"from": "00:00", "to": "12:00", "days": "mon-sun", "eur_per_kwh": 0.2},
{"from": "12:00", "to": "24:00", "days": "mon-sun", "eur_per_kwh": 0.3}]})
_om = U.options_to_ui(dict(DEFAULTS, static_profile=_odd))
check("odd windows show as 'custom' and survive saving another field",
_om["ui.contract"] == "custom"
and edit(dict(DEFAULTS, static_profile=_odd), gain=0.5)
["static_profile"] == _odd)
print("\n5. region presets")
_fl = U.REGION_PRESETS["flanders"]
check("the Flanders preset is the sum of app/price.py's components, and is the "
"shipped default", _fl["taxes_eur_kwh"] == round(sum(
v for _n, v in FLEMISH_TAXES_COMPONENTS_EUR_KWH), 5)
== PRICE_OPTION_DEFAULTS["price_taxes_eur_kwh"] == DEFAULTS[
"price_taxes_eur_kwh"])
check("every preset carries its year", all(
isinstance(p["year"], int) and p["year"] >= 2026
for p in U.REGION_PRESETS.values()))
_own = dict(DEFAULTS, price_taxes_eur_kwh=0.06)
check("a figure that is no preset reads as 'own', and choosing Flanders "
"writes the preset", U.options_to_ui(_own)["ui.region"] == U.OWN
and edit(_own, ui__region="flanders")["price_taxes_eur_kwh"] == 0.11736)
_prof = dict(DEFAULTS, price_taxes_eur_kwh=0.12,
price_taxes_profile='{"day": 0.14, "night": 0.1}')
check("'own' keeps a stored levies table when the figure is edited",
edit(_prof, price_taxes_eur_kwh=0.13)["price_taxes_profile"]
== _prof["price_taxes_profile"])
check("'own' stores the typed figure",
edit(DEFAULTS, ui__region=U.OWN, price_taxes_eur_kwh=0.13)
["price_taxes_eur_kwh"] == 0.13)
print("\n6. arbitrage_enabled: the OPT-11 hook changes nothing yet")
check("the hook answers None while battery modes do not exist",
U.arbitrage_from_batteries(U.options_to_ui(DEFAULTS)) is None)
check("so the toggle is stored as the page has it",
edit(DEFAULTS, arbitrage_enabled=True)["arbitrage_enabled"] is True)
print()
if fails:
print(f"{len(fails)} FAILED")
sys.exit(1)
print("all passed")
+41
View File
@@ -1808,6 +1808,47 @@ check("an UNREADABLE shadow_mode resolves to SHADOW, not to live - the "
and shadow.engaged({"shadow_mode": ""}, control_started=True) is True
and shadow.mode({"shadow_mode": "garbage"}) == "on")
# --------------------------------------------------------------------------- #
print("\nUX-13 - the warning tier: notes for the settings page, never refusals")
from app.validate import Note, WATT_ENTITY_KEYS, config_notes # noqa: E402
_warned = base(integrator_max_w=3000, maintenance_discharge_w=2500,
price_provider="generic_dayahead", static_profile="")
_notes = []
_with = validate_startup_config(_warned, -5000, 5000, notes=_notes)
check("a config with three logged warnings starts, and gives three notes, "
"each filed under the setting it names",
_with == [] and validate_startup_config(_warned, -5000, 5000) == []
and sorted(n.keys for n in _notes) == [
("integrator_max_w",), ("maintenance_discharge_w",),
("static_profile",)]
and all(n.tier == "warn" and f"({n.keys[0]})" in n.text for n in _notes))
_refused = base(setpoint_entity="", integrator_max_w=3000)
_n2 = []
check("collecting notes changes no refusal",
validate_startup_config(_refused, notes=_n2)
== validate_startup_config(_refused) != [] and len(_n2) == 1)
_rows = {"number.goodwe_setpoint": {"unit": None},
"sensor.soc": {"unit": "%"}, "sensor.batt": {"unit": "kW"}}
_cn = config_notes(base(), entities=_rows)
check("a battery power sensor in kW is warned about: the add-on takes it as "
"watts", [n.keys for n in _cn] == [("batt_entity",)]
and "kW" in _cn[0].text)
_cn = config_notes(base(meter_entity="sensor.grid"), entities={})
check("an entity Home Assistant does not have is named, and only the ones "
"this meter source and roster shape read",
sorted(n.keys[0] for n in _cn) == ["batt_entity", "meter_entity",
"setpoint_entity", "soc_entity"])
check("with no entity list (Home Assistant down) those checks are skipped",
config_notes(base(), entities=None) == [])
check("a peak limit below this month's peak is warned about",
[n.keys for n in config_notes(base(peak_cap_w=2500),
month_peak_w=2900)] == [("peak_cap_w",)]
and config_notes(base(peak_cap_w=3500), month_peak_w=2900) == [])
check("pv.py converts solar units itself, so no solar key is read as watts",
not [k for k in WATT_ENTITY_KEYS if k.startswith("pv_")]
and isinstance(_cn[0], Note))
# --------------------------------------------------------------------------- #
print()
if fails:
+22 -8
View File
@@ -1422,14 +1422,28 @@ for _t in range(0, 400, 5):
_wd_unit.evaluate(-1000.0, 1500.0, True, T0 + timedelta(seconds=_t))
print(f" site: {_wd_site.reason!r}")
print(f" unit: {_wd_unit.reason!r}")
check("⚠️ THE SITE INSTANCE'S SENTENCE IS BYTE-IDENTICAL TO THE ONE THAT "
"SHIPPED. It is what an operator reads on the status page, what goes in "
"the action log and what is persisted to /data/state.json, so it is "
"asserted against the literal rather than against a format string",
_wd_site.reason == (
"SIGN_DISAGREEMENT: commanded -1000 W against a meter reading "
"+1500 W for 180 s continuously (limits: both over 300 W, held over "
"180 s)"))
# UX-11: this was a byte pin. The reason is now the evidence: the action
# log, the DEBUG line and /data/state.json carry it, and the ERROR line quotes
# only its code (`messages.reason_code()`). So what is pinned is what it says:
# the code in front, where every saved reason has had it and where the ERROR
# line finds it, then the command and the reading in that order (habit 14),
# the time held and both limits.
_sr = _wd_site.reason
_order = [_sr.find(t) for t in ("commanded -1000 W", "meter reading +1500 W",
"for 180 s", "both over 300 W",
"held over 180 s")]
check("⚠️ THE SITE INSTANCE'S REASON SAYS WHAT SHIPPED, IN THE SAME ORDER: "
"the code first, then what was commanded, what the meter read, how "
f"long, and the two limits ({_order})",
_sr.startswith("SIGN_DISAGREEMENT: ")
and messages.reason_code(_sr) == "SIGN_DISAGREEMENT"
and all(i > 0 for i in _order) and _order == sorted(_order))
# UX-11 review: the text itself did not change, and it is what state.json
# holds, so the byte pin stays beside the meaning pin.
check("...and it is still byte-identical to the one that shipped",
_sr == ("SIGN_DISAGREEMENT: commanded -1000 W against a meter reading "
"+1500 W for 180 s continuously (limits: both over 300 W, held "
"over 180 s)"))
check("...and the per-unit instance names what it ACTUALLY compared instead. "
"'against a meter reading' there would be a false statement about which "
"instrument produced the evidence, on the one line somebody woken by "
+97
View File
@@ -0,0 +1,97 @@
#!/usr/bin/env python3
"""SAFETY-52's evidence: the 16-day capture replayed with and without the
battery-refuses hold. `python3 tools/replay_refusal.py`
Same disturbance, fitted plant and pack floor as `replay_recorded_loop.py`,
plus main.py's reseed, 15 s input hold and 0 W rules and the REAL SAFETY-37/57
gate on a register published every 10 s. `old` is `compute()` with
`refused=None`, which is release/1.0's law unchanged; `new` carries the refusal,
runs the probe on main.py's clock and seeds a refusal from a gate trip.
Modelled watt-hours: read the deltas, not the absolutes (see that tool).
"""
import math
import pathlib
import sys
ADDON = pathlib.Path(__file__).resolve().parent.parent
sys.path.insert(0, str(ADDON))
sys.path.insert(0, str(ADDON / "tools"))
import replay_recorded_loop as R # noqa: E402
from app import freshness, control as NEW # noqa: E402
def go(which, rows, fit, publish_s=10.0, stale_input_s=15.0):
law = NEW
tun = law.Tuning(**R.LIVE)
t0, g0, b0, sp0, soc0 = rows[0]
pl = R.Plant(*fit[:4], soc0); pl.seed(t0, b0, sp0)
st = dict(target=sp0, i_w=sp0, sat=0, loop_w=sp0, ref=0, anchor=None)
fr = freshness.Freshness(freshness.BOUNDS["batt"]); reg, reg_t = None, -1e18
bad, trips, was = None, 0, False
M = dict(und=0.0, imp=0.0, exp=0.0, q={}, run=0.0, mx=0.0, last=None, refh=0.0, probes=0)
for i in range(1, len(rows)):
t, gr, ba, sp, soc = rows[i]
dt = t - rows[i - 1][0]
if dt > R.TICK_CAP_S:
pl = R.Plant(*fit[:4], soc); pl.seed(t, ba, sp)
st.update(target=sp, i_w=sp, sat=0, loop_w=sp, ref=0, anchor=None)
fr = freshness.Freshness(freshness.BOUNDS["batt"]); reg_t = -1e18; bad = None
continue
b = pl.step(t, dt, st["target"]); grid = gr + ba - b
if t - reg_t >= publish_s:
reg, reg_t = float(round(b)), t
fr.submit(reg, st["target"], t); batt = fr.reading()
if fr.stale and not was:
trips += 1
if (which == "new" and not st["ref"] and st["sat"] >= tun.saturation_cycles
and abs(reg) < NEW.REFUSED_BELOW_W and abs(st["target"]) > tun.saturation_w):
st["ref"], st["anchor"] = (1 if st["target"] > 0 else -1), t
was = fr.stale
if batt is None:
bad = t if bad is None else bad
if t - bad >= stale_input_s:
st.update(target=0.0, i_w=0.0, loop_w=None)
else:
bad = None
if st["loop_w"] is None or st["target"] != st["loop_w"]:
st["i_w"] = st["target"]
if which == "old":
d = law.compute(st["target"], grid, batt, tun, st["sat"], st["i_w"],
refused=None)
else:
probe = False
if st["ref"] and st["anchor"] is not None:
h = t - st["anchor"]
if h >= NEW.PROBE_EVERY_S + NEW.PROBE_S: st["anchor"] = t
else: probe = h >= NEW.PROBE_EVERY_S
d = law.compute(st["target"], grid, batt, tun, st["sat"], st["i_w"], refused=st["ref"], probe=probe)
if d.refused and not st["ref"]: st["anchor"] = t
if not d.refused: st["anchor"] = None
if probe and d.target_w == NEW.PROBE_W and M["last"] != NEW.PROBE_W: M["probes"] += 1
st["ref"] = d.refused
st.update(sat=d.sat_count, i_w=d.i_w, loop_w=d.target_w, target=d.target_w)
tg = st["target"]
if tg - b > 1000: M["und"] += dt / 3600
if st["ref"]: M["refh"] += dt / 3600
M["imp"] += max(0, grid) * dt / 3.6e6; M["exp"] += max(0, -grid) * dt / 3.6e6
k = math.floor(t / 900); a = M["q"].setdefault(k, [0.0, 0.0]); a[0] += grid * dt; a[1] += dt
M["run"] = M["run"] + dt if (M["last"] == tg and abs(tg) >= 250) else 0.0
M["mx"] = max(M["mx"], M["run"]); M["last"] = tg
worst = max(max(0.0, s / d) for s, d in M["q"].values() if d > 600)
return trips, M, worst
def main():
rows = R.stream()
fit = R.fit_plant(rows, stride=7)
print(f"fit {[round(x, 2) for x in fit]}, {len(rows)} meter instants")
for label, f in (("fitted plant", fit),
("plant offset 0 W", (fit[0], fit[1], fit[2], 0.0, fit[4]))):
for which in ("old", "new"):
tr, M, w = go(which, rows, f)
print(f"{label:17s} {which}: gate trips {tr:4d} | request >1 kW above "
f"delivery {M['und']:6.1f} h | longest held >=250 W "
f"{M['mx'] / 3600:5.2f} h | import {M['imp']:6.1f} kWh export "
f"{M['exp']:5.1f} kWh | worst 15-min {w:5.0f} W | refused "
f"{M['refh']:5.1f} h, probes {M['probes']}", flush=True)
if __name__ == "__main__":
main()
@@ -0,0 +1,106 @@
"""UX-13: record every `validate_startup_config()` call the test suite makes,
and compare two validators over those calls.
python3 tools/ux13_validator_calls.py record OUT.jsonl.gz
python3 tools/ux13_validator_calls.py compare OLD_APP_PARENT OUT.jsonl.gz
`record` runs each test_*.py with the validator wrapped (in this directory, so
run it where the suite runs: the CI image). `compare` runs the recorded calls
through the validator under OLD_APP_PARENT (a directory holding an `app/`,
e.g. from `git archive <base> goodwe_controller/app`) and through this tree's,
and prints every call whose refusals differ. P0 of UX-13 used it to show that
adding the warning tier changed no refusal. scenarios/ux13/ holds the record
test_uimodel.py round-trips.
"""
import gzip
import json
import os
import subprocess
import sys
HERE = os.path.dirname(os.path.dirname(os.path.abspath(__file__)))
_WRAP = r"""
import json, runpy, sys
sys.path.insert(0, ".")
from app import validate
real = validate.validate_startup_config
out = open(sys.argv[1], "a")
def rec(opts, dev_min=None, dev_max=None, *a, **kw):
try:
out.write(json.dumps({"opts": opts, "dev_min": dev_min,
"dev_max": dev_max}) + "\n")
except (TypeError, ValueError):
pass
return real(opts, dev_min, dev_max, *a, **kw)
validate.validate_startup_config = rec
sys.argv = sys.argv[2:]
try:
runpy.run_path(sys.argv[0], run_name="__main__")
except SystemExit:
pass
"""
def record(out_path):
tmp = out_path + ".part"
open(tmp, "w").close()
rows, seen = [], set()
for name in sorted(f for f in os.listdir(HERE)
if f.startswith("test_") and f.endswith(".py")):
before = sum(1 for _ in open(tmp))
subprocess.run([sys.executable, "-B", "-c", _WRAP, tmp, name],
cwd=HERE, stdout=subprocess.DEVNULL,
stderr=subprocess.DEVNULL)
with open(tmp) as fh:
for line in list(fh)[before:]:
call = json.loads(line)
key = json.dumps(call, sort_keys=True)
if key not in seen:
seen.add(key)
rows.append(dict(call, source=name))
os.remove(tmp)
with gzip.open(out_path, "wt") as fh:
for row in rows:
fh.write(json.dumps(row, sort_keys=True) + "\n")
print(f"{len(rows)} distinct validator calls -> {out_path}")
def _run(app_parent, path):
code = r"""
import gzip, json, logging, sys
logging.disable(logging.CRITICAL)
sys.path.insert(0, sys.argv[1])
from app.validate import validate_startup_config as v
out = []
for line in gzip.open(sys.argv[2], "rt"):
c = json.loads(line)
try:
out.append(v(c["opts"], c["dev_min"], c["dev_max"]))
except Exception as e:
out.append("raised " + type(e).__name__)
print(json.dumps(out))
"""
got = subprocess.run([sys.executable, "-B", "-c", code, app_parent, path],
capture_output=True, text=True, check=True)
return json.loads(got.stdout)
def compare(old_parent, path):
old, new = _run(old_parent, path), _run(HERE, path)
differ = [i for i, (a, b) in enumerate(zip(old, new)) if a != b]
print(f"{len(old)} calls, {sum(1 for r in old if r)} refused by the old "
f"validator, {len(differ)} with different refusals")
for i in differ:
print(f" call {i}:\n old {old[i]}\n new {new[i]}")
return 1 if differ else 0
if __name__ == "__main__":
if len(sys.argv) == 3 and sys.argv[1] == "record":
record(sys.argv[2])
elif len(sys.argv) == 4 and sys.argv[1] == "compare":
sys.exit(compare(sys.argv[2], sys.argv[3]))
else:
sys.exit(__doc__)