22c016fadd |
CFG-04 fix round: the probe now measures the key it is cited for
checks / unit (pull_request) Successful in 4m33s
Review blocked this on ONE finding, and it was in the EVIDENCE, not the code.
The design and the shipped behaviour are unchanged.
THE INSTRUMENT DID NOT MEASURE WHAT FOUR DOCUMENTS SAID IT MEASURED
tools/supervisor_shape_probe.py section B validated the RECONSTRUCTED LIVE
options blob - which is missing many required keys that have nothing to do with
this card. Its refusal therefore named whichever of THOSE the validator reached
first: the committed transcript recorded `meter_freeze_s`, the reviewer's run
printed `p1_phase_export_entities`, and a run today printed `sign_disagree_w`.
The string those documents quoted - `Missing option 'inverters' in root` - was
never produced by the instrument.
And section B asserted a bare `not ok`. Any refusal at all satisfied it, so
deleting `inverters: []` from config.yaml left it printing PASS: the probe could
not detect the one regression it is the committed evidence for.
THE UNDERLYING CLAIM IS TRUE AND IS NOW MEASURED PROPERLY
Section B is an ISOLATED COUNTERFACTUAL now: the full shipped `options:` block
(expect accept), and the SAME block with `inverters` removed and nothing else
varying (expect refusal). One key differs, so the refusal has nowhere else to
come from - and the assertion is on the KEY NAME IN THE REFUSAL STRING, so the
line goes red if the refusal is ever about a different key. The probe also exits
non-zero when any case fails; without that a transcript is only evidence to
someone who reads it.
The old live-blob case survives as section B2, relabelled for what it is: an
incomplete reconstruction whose RAW half is refused for unrelated missing keys,
kept because its MERGED half genuinely demonstrates what App.options is.
VERIFIED BY BREAKING IT, WHICH IS THE WHOLE POINT
`inverters: []` deleted from config.yaml, probe re-run against
ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0:
== B. THE LOAD-BEARING ONE: an options blob with no `inverters` key ==
FAIL the shipped `options:` block validates AS IT STANDS - ...
Missing option 'inverters' in root in GoodWe RS485 Controller
...
== 2 CASE(S) FAILED ==
exit 1. Key restored, same image, same command: `== all cases passed ==`, exit
0. The transcript in DECISIONS is that restored run, re-run today, not the old
one.
THE FOUR MIS-CITATIONS
DECISIONS/CFG-04-inverter-roster.md section 4's "section B shows both halves"
sentence and its line-103 transcript; CHANGELOG.md; test_inverter.py's part-9
comment and its part-12 mutation row; and the PR description. All now attribute
the string to section B and say plainly what section B2 does not show. The
part-12 row additionally records that the probe was blind to that mutation until
review, because a mutation table that lists a defeat nothing catches is the
failure this repository keeps finding.
MUTATION.md gains it as the sixth instance of "the check's data cannot reach the
failure it names" - the first found OUTSIDE the suite, in a committed evidence
artifact, because nothing in that document had ever been pointed at tools/. Three
habits with it: assert on the CONTENT of a refusal rather than that one happened;
vary ONE thing, from an ACCEPTED baseline; and treat a committed transcript as a
check subject to the mutation battery.
TWO NON-BLOCKING FINDINGS, ALSO FIXED
validate.py rules 5 and 6 NAMED THE WRONG INVERTER. `unit_caps()` SKIPS an
entry with no usable `max_w`, so caps position i stops being roster position i
the moment one entry is malformed - and rule 5 fed `caps.index(weakest)` to
`_unit_label()`, which indexes the roster, while rule 6 paired `caps[0]` with a
hard-wired `_unit_label(opts, 0)`. Right number, another inverter's name: an
operator sent to the wrong device by the message that exists to stop that. New
`unit_caps_indexed()` carries the roster index with the cap. It is latent -
rule 9(d) refuses such a config in the same pass - but that was a property of
today's rule ordering, not of the code, and validate_startup_config() is also
sim/inject.py's entry point. Part 10 gains a check that asserts the fixture
really does desynchronise the two lists, then that both messages name the right
unit, then the counterfactual: the OLD expressions, on that same config, still
evaluate to the wrong names.
DOCS.md called a downgrade "safe". True of the SCHEMA - the older schema drops
the key with a warning - and incomplete about the ADD-ON: rule 9(e) requires the
flat `setpoint_entity` be cleared when a roster is declared, so a config that
downgrades cleanly is by construction one whose flat actuator is blank, and the
older version has nothing to write to. Confirmed by running release/1.0's own
validate_startup_config() on that blob: one refusal, naming setpoint_entity.
Recoverable and loud, but an outage until a field is refilled. The note says so
now, and tells the operator to write the entity down before downgrading.
19/19 green in the goodwe-addon-ci image.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
753f700539 |
DEV-02: merge release/1.0, and close the two review blockers
checks / unit (pull_request) Successful in 4m15s
PR #43 was rejected on two findings and had gone unmergeable behind SAFETY-28 and the ALLOC-01 fix. This is the merge commit; the conflict resolution and both fixes are below, because a merge that also changes behaviour has to say so. THE MERGE, AND WHAT IT COST =========================== Two conflicts in main.py, both where SAFETY-28 and this card touched the same method: * `write_setpoint()` split into a site entry point plus a per-unit `_write_unit()` here, while SAFETY-28 put its record gate in the old single-unit body. `write_refusal()` now takes the INVERTER it is about. Asking it with `self.unit` - as release/1.0 does - would authorise A's share on B's wire, and would also trip test_inverter.py part 1's AST scan, which goes red on any read of a Controller N=1 view inside Controller. * the SAFETY-28 gate sits above the clamp and below the non-finite coercion, exactly where release/1.0 put it, and is now asked about `inv`. Fallout the merge produced in the checks, re-aimed rather than relaxed: * every fixture that calls `write_setpoint()` DIRECTLY - the clamp probe, the hung-heartbeat experiment and its serialised counterfactual, the split deadline probe - now arms a real allocation record first. test_inverter.py grows an `arm()` built through the shipped `resolve()`, the same shape test_clamp.py's is: the per-unit envelopes are filed as real `supervised` claims and the site target is their sum, so the water-fill has exactly one answer and the fixture cannot quietly become its own allocator. * test_clamp.py's two-unit failsafe fixture assigned `c.units`, which DEV-02 made a derived property with no setter. It appends a real `Inverter`. BLOCKER 1 - AC 4's ARBITER-BOUND EVIDENCE WAS VACUOUS ===================================================== test_peakguard.py claimed "each unit's `supervised` bound is ITS OWN `max_w` - give inverter B a different rating and the claim filed on inverter B moves with it", and compared B's bound against `_b2.max_w`. `second_inverter()` DEFAULTED B's rating to `LIVE_MAX_W`, which is A's. IT COMPARED (-5000, 5000) AGAINST (-5000, 5000): a number against itself, unable to observe the failure it named. Reproduced: filing the per-unit `device`/`supervised` claims from `self.inverters[0]`'s numbers while leaving `actuator=self.actuator_of(..., inv)` alone left ALL 19 FILES GREEN. At a roster of two with A=5000/B=3000 that makes inverter B's planned envelope (-5000, 5000) instead of (-3000, 3000) - a 2000 W over-command the arbiter believes is supervised. It is a DIFFERENT defect from the actuator variant the static routing pin catches, and only the actuator variant was in the mutation table. * `second_inverter()` gives B 3000 W - a hypothesis, marked as one - for every fixture in the file, so no check there can compare B against A by accident. * the claim is asserted against LITERAL numbers rather than against an expression that can read the same object twice, for `supervised` AND for `device` (whose `dev` had the same defect), plus the envelope the ARBITER RESOLVED for B - a claim filed right and resolved wrong is the same defect one layer down. * a PRECONDITION check fails if the two ratings are ever made equal again. * the BOUND mutation is in the table, beside the actuator one, and was observed RED (3 checks in test_peakguard.py) via tools/mutation_run.sh. ⚠️ THIRD INSTANCE THIS SESSION of a check whose DATA cannot reach the failure it names - ARB-03's call-site scan saw 3 of 8 appends, ALLOC-01's replay generator saw 0 escapes where a widened one saw 39,991. MUTATION.md gains a section for it beside the stale-bytecode and masking ones, and the rule is written at the line: ANY CHECK ASSERTING "X DIFFERS FROM Y" MUST BE RUN ONCE WITH X AND Y ACTUALLY MADE DIFFERENT. BLOCKER 2 - THE LATCH WAS SILENTLY DISARMED BY THE ROLLBACK ROUND TRIP ====================================================================== store.py's rule 2 keeps the flat keys "so a rollback still finds its latch". The operator path that rule contemplates is a ROUND TRIP, and this card lost the latch on it: 1. install migrates -> schema_version=1, unit/inverter-a/... = False 2. operator DOWNGRADES; SAFETY-02 trips inside the downgrade window and the old add-on writes only the flat `sign_tripped: true` 3. operator upgrades again -> `rep.ran` is False, so `_grade_store_migration()` returned early, and `Inverter.__init__` read the namespaced key: False Observed: the controller came up with `sign_wd.tripped = False` while /data/state.json said `sign_tripped: true`. That is store.py's own header sentence - "the file still says sign_tripped: true, the banner is green, and the controller resumes driving the wrong way" - rebuilt by the version marker. A firmware version change with a rollback path was performed on this site on 2026-09-02, so this is not hypothetical. Three changes, each graded by a mutation observed RED: * THE OPERATOR'S CLEAR CLEARS BOTH SPELLINGS. That is what removes the "re-arm forever" objection the `rep.ran` gate existed to answer: with the fossil cleared, `flat True + namespaced False` is unambiguously a downgrade-window latch. * A TRIP MIRRORS THE FLAT PAIR. Rule 2 only ever covered the latch present AT MIGRATION TIME - nothing flat was written for a trip taken afterwards, so an operator who downgraded found `sign_tripped: false` and came up DRIVING. store.py claimed the staleness could only fail toward a SPURIOUS latch. It could not; that sentence is corrected rather than left standing. * THE GUARD RUNS ON EVERY START, and asks the STORE - not the roster - whether anything namespaced is latched. A mirrored trip on B must not re-arm a healthy A, and the store is the right place to ask because it holds every `unit/*/sign_tripped` this install has written, including one belonging to a unit that is not in today's roster. Graded by the three-step scenario itself, run end to end in test_inverter.py part 2, with all three preconditions asserted - including that the catching start did NOT migrate anything, which is what used to skip the guard. Part 2's idempotence check now PRESSES the button instead of hand-writing the store, because the state it used to construct is not one the shipped clear path can produce. Part 3 grades the mirror and the clear on a real roster of two. test_watchdog.py's "the flat key is NOT written" assertion is re-aimed rather than deleted: its argument was right about the READ and wrong about the WRITE. Nothing at runtime reads that key, and the one thing that does ignores it whenever any namespaced latch is set - which a sibling's trip always leaves. What its absence actually cost was the rollback. HANDOVER.md and DOCS.md said the flat key "is never read again", which was the instruction an operator clearing a trip by hand would follow. Both corrected: it is a maintained rollback view, it IS read on every start, and clearing a trip by hand means clearing both spellings. MUTATIONS THIS ROUND, each applied on a purged tree via tools/mutation_run.sh and observed RED: * per-unit `device`/`supervised` BOUNDS from `self.inverters[0]`, actuator left correct -> test_peakguard.py 10g * `_grade_store_migration()` gated on `rep.ran` -> test_inverter.py part 2 * the operator's clear leaving the flat keys set -> test_inverter.py part 2/3 * a trip not mirroring the flat pair -> test_inverter.py part 3 * the guard asking only `self.inverters[0]` -> test_inverter.py part 3 19/19 files green on the merged tree. No hardware was touched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
d48c6b971d |
DEV-02: correct the operator instruction the latch rename made wrong
checks / unit (pull_request) Successful in 4m13s
HANDOVER.md told an operator to "delete `sign_tripped` from /data/state.json" to clear a sign-disagreement trip by hand. After this card that key is a FOSSIL: the live latch is `unit/<inverter>/sign_tripped`, and the flat one is left in the file only so a rollback finds its latch and is never read again. Following the old instruction would delete a key that clears nothing, on the one path an operator reaches while staring at a FAILSAFE banner - so the instruction would look like it had failed. DOCS.md's §SAFETY-02 section named the file but not the key; it now names both, and says why there is one per inverter. No code change; the suite is unaffected and green. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e941bf7f62 |
DEV-02: zero every unit's target when the operator stops, not just the site's
checks / unit (pull_request) Successful in 4m12s
A hazard THIS CARD CREATED, found by re-reading the operator paths rather than by a failing check - so a check now exists for it. Before DEV-02 the heartbeat re-emitted `self.target`, so the stop button zeroing that one scalar was enough: the next refresh carried the zero. The heartbeat now re-emits `inv.target` - it has to, or it would put the SITE number on every inverter, which is the ARCH-01 broadcast fault arriving once every `heartbeat_s` on a path with no allocator in it. So a stop that zeroed only `self.target` left each unit's LAST SHARE standing. No cycle has run yet at that moment, so nothing else would have cleared it, and the very next heartbeat - up to `heartbeat_s` later - would put it back on the wire. The operator presses stop, watches the inverter go to zero, and sees it resume seconds later. `command_site_zero()` moves both together and carries the reason. It is one method rather than two lines at three call sites precisely because the two lines have to stay together: shutdown(), the stop button and maint_abort all mean the same thing, and 0 W is the one value that may legitimately be written site-wide. test_inverter.py part 6 presses stop with 995/995 standing and then runs the SHIPPED `send_heartbeats()` before any cycle, which is the racing refresh. The mutation that zeroes the site target alone takes it red. 19 files green. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e306c74cb8 |
DEV-02: per-instance inverter objects, so nothing is graded against a sibling
checks / unit (pull_request) Successful in 4m15s
Every piece of per-device state in the Controller was a scalar, and several of
them are safety inputs. app/inverter.py introduces an `Inverter` that owns its
entities, its rating, its device range, its SignWatchdog, its last_write and
its last_beat, under store keys namespaced by unit name. The Controller holds a
list of them and keeps only what is genuinely site-level: the P1 reading, the
site integrator, and the tariff quarter.
WHAT THE SCALARS WERE SILENTLY ASSERTING
dev_min/dev_max one pair, read from one setpoint_entity. A second
inverter's rating was NEVER READ AT ALL, so its clamp, its
freeze rail and the peak guard's achievable_w were the
first one's numbers.
soc one reading into the maintenance FSM, SAFETY-24's pack
floor and arbitrage's bounds. An average lets the emptier
pack be driven below its own floor.
sign_wd ONE SignWatchdog, whose own docstring says "one instance
per actuator", latched under FLAT store keys - so a trip
caused by B latched A across restarts and one operator
press cleared both.
last_beat one deadline and one serialised hass.call(), so a hung
write to A ate B's 30 s layer-1 budget.
actual_w BECAME SITE LEVEL WHILE THE READINGS BECAME PER-INSTANCE, and those
are opposite directions on purpose. compute()'s anti-windup test is
`abs(prev_w - actual_w) > saturation_w` with prev_w the SITE target, so feeding
it one inverter's power compares a site number against a unit number, trips the
saturation freeze permanently and leaves a standing grid error. Measured on
admin/goodwe's two-master rig (tools/alloc_sim.py --splits, 2 kW load, 40
cycles), worst |delta| between splits at the meter:
gain one unit's power the site sum
0.2 510 W 0 W
0.4 250 W 0 W
0.6 50 W 0 W
That was ALLOC-01's disclosed finding; test_alloc.py part 8 kept its stimulus
and now grades the other row.
THE STORE MIGRATION IS GRADED, NOT MERELY PERFORMED. sign_tripped/sign_reason
move to unit/<name>/... once, verified by READING BACK what was written, and
the version marker is set only when nothing that carried state was lost. The
flat keys stay in the file so a rollback still finds its latch. And __init__
compares the pre-migration flat latch against what unit A actually came up
with: if the latch did not survive it is RE-ARMED from the legacy value and
shouted about. A latch that silently fails to migrate is a disarmed safety
guard on an install whose state file says it is protected - which is strictly
worse than never persisting it, because now there is evidence saying it is
fine. test_inverter.py part 2 breaks the migration and watches the guard fire.
HEARTBEATS ARE INDEPENDENT AND THE BUDGET IS DERIVED. Each inverter owns its
deadline, the refreshes go out concurrently, and each write is bounded by
WRITE_BUDGET_S = 4 s. The inequality is graded rather than asserted: 4 +
heartbeat_s's schema maximum of 25 < 30, validate.FIRMWARE_INGEST_VETO_S.
Verified by injecting a transport that accepts and never answers.
live_units() ANSWERS HONESTLY. A unit whose every write has been rejected for a
whole layer-1 window is not commandable; the allocator drops it, the survivors
carry its share, the action log names it, and the dropped unit is commanded
0 W rather than left standing on its last share. A roster entry with NO
setpoint_entity is deliberately not handled there - that is a configuration
that cannot be delivered, and it reaches main.py's refusal branch, which is how
that branch keeps a live trigger after this card removed its old one.
AT N=1 NOTHING MOVES. The removed scalars survive as read/write properties of
the sole inverter, so every existing replay runs unmodified - and they REFUSE
at N>=2 rather than answering for the first inverter, which is the tripwire on
a consumer that was never made per-instance.
EVIDENCE. 19 files green. test_inverter.py is new (82 checks). Eighteen
mutations were applied to the shipped modules on a purged tree via
tools/mutation_run.sh and each was observed RED. Two of them SURVIVED first
time and the checks were changed rather than the table: the serialised dispatch
and the shared last_beat both passed while part 6 gathered its own writes and
computed its own `due` list. send_heartbeats() was extracted from run_control()
so the shipped dispatch is reachable by a check at all.
INVERTER B STILL DOES NOT EXIST. build_roster() returns exactly one inverter
from the flat options and is the one function CFG-04 changes; every two-unit
figure here is architecture, and the second rating in the checks is marked a
hypothesis.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
3fe3c7acb0 |
ALLOC-01: clamp each envelope end on its own, and widen the replay that missed it
checks / unit (pull_request) Successful in 4m9s
Two blocking findings from the review of
|
||
|
|
186e13ceca |
ALLOC-01: allocate the site grid target, sum-invariant, never broadcast
checks / unit (pull_request) Successful in 4m6s
ARB-03 left `allocate()` as a documented seam that passed through at N<=1 and
DECLINED at N>=2, with the reasoning recorded at the line: the obvious
placeholder - hand the site target to each inverter - IS the ARCH-01 fault, and
"a placeholder that cannot be told apart from the real thing by any guard we
have is worse than no placeholder". This fills the seam.
WHY A BROADCAST IS A FAULT AND NOT AN INEFFICIENCY. The control primitive is
meter emulation: the master reports a FABRICATED grid reading and the inverter
regulates itself to it, so one number means "the battery moves X W" to this
add-on and "the grid is at X W" to the inverter - an identity that holds only at
N=1. Hand two inverters the same target and each supplies it IN FULL, so the
loop gain at the meter becomes N times the per-unit gain. Reproduced on
admin/goodwe's two-master rig against this tree: -400 W export overshoot at
gain 0.6, and at gain 1.0 - which config.yaml accepts as its documented maximum
- a permanent 4000 W peak-to-peak limit cycle, commands alternating
1000/2000/1000/0 W, with NOT ONE GUARD FIRING. The sign watchdog is evaluated on
every cycle and never trips, because the disagreement flips on alternate ticks
and never holds its 180 s window.
WHAT WAS BUILT. `app/allocator.py`, host-side and strictly above the driver
seam. It consumes intervals and a number and nothing else - no claims, no
priorities, and no measurement, because an allocator that read P1 would be a
SECOND integrator on the site measurement.
* ENVELOPE CLAMP, from ARB-03 stage 1's `UnitBounds`, read PER TICK. `plan()`
is a pure function and the module holds no state, so there is nowhere for a
construction-time envelope to be cached.
* WATER-FILL by weight, with the surplus of a full unit moving to the others.
Weights express PREFERENCE, envelopes express PERMISSION: a zero weight is
honoured while another unit has headroom and overridden when it does not,
because the SUM is the safety property and stranding capacity behind a
comfort choice manufactures a standing error at the meter.
* LARGEST-REMAINDER ROUNDING. The target is rounded ONCE, at the top; every
sum below that line is integer arithmetic, so it cannot drift. Measured: a
per-unit round() drifts -125 W over 50 000 ticks at three inverters.
* THE ALLOCATION RECORD, with `unmet_w`, `dropped` and a per-unit reason.
`ok` is one boolean for SAFETY-28 to gate on, and `unmet_w` is deliberately
NOT fused into it - a saturated inverter must not park the whole site.
THE STABILITY PROPERTY IS STRUCTURAL. With sum(a_i) = 1 the gain at the meter is
sum(a_i * g_i), a convex combination of the per-unit gains, so it lies in
[min g_i, max g_i] FOR ANY SPLIT. That is what makes the weights a comfort
choice rather than a tuning parameter, and it is why a bad split cannot
destabilise the site. Graded directly, and measured end to end: 90/10, 50/50 and
100/0 give a bit-identical aggregate trace at the meter, and a gain sweep to 1.0
at every split has a flat tail at all 84 combinations.
THE TWO REFUSALS main.py NOW MAKES, AND WHY THERE ARE TWO. `allocated=False` no
longer means "no allocator"; it means no safe split EXISTS - a mis-routed claim,
an empty envelope set, or a split that could only be made by commanding one pack
to charge while another discharges. Separately, and this guard is the price of
making allocate() succeed rather than something inherited, main.py refuses to
act on a valid split it cannot DELIVER: there is one `setpoint_entity`, so
writing the site target to the one inverter it can reach would over-command that
inverter by exactly the other's share. Commanding a partial site is a worse
instruction than commanding nothing. DEV-02 gives it the second writer.
scope_violations() IS NOW CONSUMED, AND AS A REFUSAL. ARB-03 left it logging
without changing the resolution. A mis-routed claim means the number about to be
divided may itself be wrong, and dividing a number that may be wrong is worse
than not dividing it - the same answer clause 3 already gives a contradiction.
It is NOT promoted into an envelope: a unit-scoped claim that landed on the site
names no unit, so promoting it would mean guessing one, or applying one
inverter's rating to a sibling that does not have it.
AT N<=1 IT IS A PASS-THROUGH, BYTE-IDENTICAL: the share is the site target, as a
float, unrounded and unclamped. All 17 existing suites replay unedited.
test_peakguard.py part 10h and test_arbiter.py part 7 were RE-AIMED, not
deleted. PR #40's reviewer proved that refusal branch was unreachable and
untested once; removing its trigger without giving it a new one would have
rebuilt the hole. Part 10h now drives three real cycles - a deliverable split, a
dead sibling, and every master stale - and grades all three.
KNOWN AND NOT CLOSED HERE: at a roster of two the loop's `actual_w` is one
inverter's power used as a site measurement, because the add-on binds a single
`inverter_power` sensor. That is the SENSING half of the same N=1 identity this
card removes from the COMMANDING half, and it makes the aggregate trace
split-dependent below gain 1.0. Measured with its counterfactual in test_alloc.py
part 8 and tools/alloc_sim.py --splits. It belongs to DEV-02.
Verified: all 18 suites green in the CI image. 16 mutations run through
tools/mutation_run.sh on a purged tree; 13 red, and the 3 survivors are recorded
in test_alloc.py part 12 with the reason each cannot be caught.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
38f6680639 |
ARB-03: pin all eight actuator call sites statically
checks / unit (pull_request) Successful in 3m45s
The independent review of PR #40 found AC 6 met at three of the eight claim construction sites while the check claimed to cover the class - this repository's named failure mode, a check observing something other than what it claimed, reproduced inside the check written to prevent it. WHAT WAS WRONG. Part 10g's only call-site check was a real two-inverter cycle. That cycle is auto, P1-healthy, no maintenance procedure, no tripped sign watchdog, the guard idle and arbitrage off, so it reaches `device`, `supervised` and `loop` and nothing else - three of the eight direct appends in `Controller.cycle()`. Its own check text nevertheless read "the line a mis-typed `actuator_of(...)` at a call site goes red on", and the PR body's mutation table presented it as covering the class. The reviewer proved the gap on the shipped tree: `actuator_of("maintenance")` -> `actuator_of("peak")` at the maintenance-shaping append left test_arbiter.py, test_peakguard.py and test_arbitrage.py ALL GREEN, while at a roster of two it built a site loop of -1500 W against the guard's site `lo` of 1500 W and the now-misrouted charge-only `hi = 0` - `lo > hi`, arbiter clause 3, 0 W IN THE BILLED QUARTER, SAFETY-25 §0a's fatal case from a one-word typo. The same mutation at the `failsafe` append survived too. The runtime detector does fire - `scope_violations()` names it - but it only logs; nothing graded it. THE FIX, over machinery already present. Part 10f's AST scan already reads each `claims.append(...)` in `Controller.cycle()`. All eight direct appends expose their actuator statically as `actuator=self.actuator_of('<literal>')`, so 10g now requires that literal to EQUAL the source the claim is filed under, read as SOURCE TEXT rather than evaluated - `actuator_of("peak")` at the maintenance append is the same VALUE at the shipped roster of one and a different string here. That pins all eight routing sites, on the line the typo is written, in every configuration and at every roster, exactly the way 10f pins the source set. Two further lines keep the scan from going vacuous: every direct append must be readable in that shape (a computed or hand-written actuator fails there), and the ten appends must still account for 10f's eight sources. The two INDIRECT appends carry no `actuator=` at the call site to mis-type. `peak_claim` and `arb_claim` are routed where their claim is built, and are pinned there - `peakguard.claim()` by the SWEEP_SITE sweep over every load x elapsed x battery x SoC x floor combination, `arbitrage.claim()` by test_arbitrage.py. 10g now says so at the line, and says which three of the eight its dynamic cycle actually sees, rather than rounding up. MEASURED, NOT ARGUED. Each of the eight direct appends mutated in turn to a wrong actuator - device->loop, supervised->peak, failsafe->safety, safety(stopped)->device, safety(inputs missing)->maintenance, maintenance(SET)->loop, maintenance(shaping)->peak, loop->supervised - each on a purged tree via tools/mutation_run.sh over all 17 files. All eight RED, every one of them on the new line. TWO SURVIVING MUTATIONS OF THE SAME CLASS, ALSO CLOSED. * `resolve()` did not have to honour the roster it was given: `if units is None:` -> `if True:` left the whole suite green. Ignoring the argument makes a unit that filed nothing this cycle cease to exist - a site of two reads as a site of one and stage 3 passes the whole grid target through to the inverter that spoke, which is ARCH-01's fault with its own evidence removed. test_arbiter.py part 7 now grades it on the one case that separates the two, a SILENT unit. Mutation RED in test_arbiter.py and test_peakguard.py. * main.py's N>=2 refusal was unreachable and ungraded: `if not resolution.allocated:` -> `if False:` left the whole suite green, so the right instinct was one refactor away from being deleted as dead code. The guard is KEPT - the alternative default is the ARCH-01 fault - and new part 10h grades it on the two-inverter cycle that already existed: the 0 W, the `failsafe` winner, the log line naming the roster size, and the write that follows. Mutation RED. AND THE WORDING CORRECTED. main.py does not "refuse to write" on `allocated=False`. It SUBSTITUTES a 0 W failsafe and then calls `write_setpoint(0.0)` like any other cycle. 0 W is the correct fail-toward-inaction direction and the log text is accurate about what it refuses - to BROADCAST the site target - but "refuses to write" overstates the code. Said as what it does, in the CHANGELOG, at the branch in main.py, and in 10h's own check text. `resolve()`'s docstring now says the roster argument has to be HONOURED, which is not the same as existing. 17/17 green on a purged tree. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
ab6fbe2f9e |
SAFETY-25: record the owner's decision - option a, with alloc-01 as the revisit trigger
checks / unit (pull_request) Successful in 3m43s
The product owner answered SAFETY-25's §1 on 2026-09-02: OPTION A. The BMS cut-out is the DELIBERATE and only backstop for demand-driven discharge on the grid-following loop, and Option B - a loop-side reserve floor - is DEFERRED rather than rejected. Option A is the shipped behaviour, so this is a recording, not a change. `app/` is touched in exactly two places and both are comments that claimed the question was still open (freeze.py's finding, peakguard.py's point 2). No setpoint, no claim, no option, no default moved. The 17-suite run is green on the same numbers as before. WHY DEFERRING IS THE SAFE DIRECTION. Option B's proof - bms_soc_floor < loop_soc_floor <= peak_soc_floor, run through the real arbiter in test_peakguard.py part 10d - has an unstated premise: the reserve predicate and discharge_permitted() read the SAME state of charge. With two packs they read different numbers. The reserve binds on the emptier pack and files hi = 0; the peak guard, reading the other pack or an average, files lo = excess > 0; lo > hi is arbiter clause 3 and the answer is 0 W - the battery parked in the billed quarter, which is the failure the memo itself marks fatal. And no config validator can catch it: it is a runtime divergence between two readings, not a config ordering, so CFG-01's shape of check passes on the exact tree that parks the battery. Option A's cost is energy; Option B's cost built too early is the one quarter of the month that sets the bill. THE REVISIT TRIGGER IS ALLOC-01, recorded in §0c. Under ARCH-01's host-side allocator the two claims stop sharing a list: the loop floor becomes a per-inverter `hi` consumed as an INTERVAL at stage A, while the peak floor stays a site `lo` at stage B. Different claim lists, different stages, structurally unable to cross - a stronger argument than the ordering rule, because it makes the crossing unreachable rather than harmless. That is the shape in which Option B becomes safe to build. WHAT HAS TO BE RE-EARNED AT N=2 is stated plainly in §0d rather than left for someone to discover. SAFETY-27 now names five floors across two packs, so "the SoC" stops being a scalar the config can bound. And part 10f - the pin that made SAFETY-25 mergeable - CANNOT EXPRESS TWO PACKS: its dynamic half is a scalar 0-100 % SoC sweep against a single-series capture, and a two-pack exposure lives in the DIFFERENCE between two readings, which that sweep visits at no resolution. Its static half, the AST scan pinning the eight claim sources, still bites at N=2; the dynamic half goes silent. Merging a two-pack reserve on 10f's current green would be merging on a check that cannot see the failure. The options analysis is kept intact on purpose - §1-§7 stand exactly as written, including §5's "(recommended)" on Option B and §6's recommendation, with a new §0 saying what was decided and §6 marked as answered. A memo that recorded the verdict and deleted the reasoning is the failure this DECISIONS/ directory exists to prevent. Part 10e's check moved with the memo: it used to pin the honest "Status: OPEN" line and now pins that the memo names the option, the date and the trigger AND still carries both options and the recommendation. The tripwire itself stays - a ninth claim source in Controller.cycle() still takes 10f red on the line it is written, and "deferred" is precisely the state in which someone builds Option B by accident. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
acbdf41248 |
TEST-13: grade record_block()'s policy argument, and the two import spellings SAFETY-20's check could not see
checks / unit (pull_request) Successful in 3m55s
Two survivors from TARIFF-01's review, closed in test_tariff.py only. app/ is
untouched and no shipped behaviour changes. Two further items on the card were
already closed in shipped code and are struck rather than re-implemented.
ITEM 1 - the per-phase reduction's PLUMBING was unobservable.
Mutating PeakStore.record_block()'s `billed_w(block, policy)` to
`billed_w(block, POLICY_NET)` (+4 B) leaves all 17 suites green. Measured
three times now: by TARIFF-01's reviewer, re-run through TEST-15's purge
harness this session, and re-run again here on a clean uncontended tree.
The product code is correct - tariff.py:363 really is
`def record_block(self, block, policy: str = POLICY_NET)` and it really does
forward the argument. What was missing is any check that could tell that
apart from a hardcoded call, and the reason is the third instance of one
shape: A STIMULUS EVALUATED WHERE THE QUANTITY IT GRADES IS DEGENERATE, after
WITNESS-02's span normalisation and TARIFF-01's own DST window.
billed_w() short-circuits to block.offtake_avg_w whenever
per_phase_offtake_avg_w is absent. Every block reaching a store anywhere in
the suite was single-phase or built as _CB(..., None) - so NET, SUM and MAX
collapsed onto one number and the argument could not be observed at the call
site. Section 7 grades the FUNCTION on an unbalanced fixture and says nothing
about its CALLER.
So section 7's own (3000, 500, -200) W block - whose three reductions are
3300 / 3500 / 3000 W, asserted distinct three lines above - is now
round-tripped THROUGH the store under each policy and read back from both
tables (peak() and recompute_month(), so both writes in that single
transaction are graded). record_block() with no policy is checked to bank the
NET figure. An anti-degeneracy pin is stated over the three BANKED numbers,
not over vals, because it is the banked ones this triple is made of.
Direction, which is why this is worth plumbing-testing: NET is the SMALLEST
of the three here, because the exporting phase nets off. A store that quietly
billed NET while asked for MAX would UNDER-record the month's peak, and an
under-recorded peak is maximum headroom for SAFETY-07 - the same
under-guarding direction as the getattr(..., 0.0) default SAFETY-07 already
removed from project().
ITEM 2 - the SAFETY-20 import grader claimed more than it checked.
It collected `m.module for m in walk(tree) if isinstance(m, ImportFrom)` and
matched a literal list of six spellings. That is blind to two of Python's
three import forms:
* `from . import arbiter as _ab` is an ImportFrom whose .module is None -
the dots are in .level and the module name is in .names - so it collected
"" and matched nothing;
* `import app.arbiter` is an ast.Import node the walk filtered out entirely.
Both were added to app/tariff.py and the shipped suite stayed GREEN, with the
_names half not firing either (an alias import creates no Name node). Low
severity: any USE of either alias still produces an Attribute the _names half
catches. But the printed sentence "it imports nothing from arbiter, clamp or
control" was false for two forms out of three, and a check that overclaims is
worse than one that claims less, because the next reader stops looking.
_imported_modules() now walks Import as well as ImportFrom and joins
`from . import X` onto its base. _forbidden_imports() matches per dotted
SEGMENT, not by substring: `app.arbiter` must not hide behind a package
prefix, and `clamps` / `arbiters` / `controller` must not be falsely flagged -
`controller` is not hypothetical, this package is goodwe_controller. Five
evasion spellings and eight innocent ones grade the grader itself, and both
the name half and the import half are shown non-vacuous against main.py,
which carries all three import forms and really does import all three modules.
ITEMS 3 AND 4 - ALREADY CLOSED. STRUCK, NOT RE-IMPLEMENTED.
Item 3: app/tariff.py:266-267 is `def is_observed(self): return self.state ==
OBSERVED`, already false for NO_RECORD. Nothing to do.
Item 4: app/tariff.py:672-680 reads `held = max(averager.held_net_w, 0.0)`
with NO getattr default, and carries a comment naming TEST-13 item 4. Fixed
by SAFETY-07 in 616b62d; held_net_w is a documented public property on
QuarterAverager (p1.py:290), so a rename raises AttributeError on the first
cycle instead of crediting 0 W held. A projection crediting 0 W held reads
LOW, which is the under-guarding direction for SAFETY-07's floor. Restoring
a default would re-open a money guard.
And the recorded NON-finding stays a non-finding: removing clear_partial()
is still green and that is a PASS. quarter_start is the PRIMARY KEY and the
upsert carries `ON CONFLICT ... WHERE excluded.offtake_avg_w >
quarter_blocks.offtake_avg_w`, so a replay is a structural no-op. That
demonstrates TARIFF-01's "double counting is answered structurally, not by
care" claim rather than contradicting it.
EVIDENCE - all through tools/mutation_run.sh (recursive __pycache__ purge,
python3 -B, tree re-read from disk, mutated line grepped off disk, byte delta
recorded), in the goodwe-addon-ci image against a :ro mount.
baseline, 17 suites, before any edit ............................ 17 PASS
baseline, 17 suites, final tree ................................. 17 PASS
A1 billed_w(block, policy) -> billed_w(block, POLICY_NET) +4 B 5 RED
the 'sum' and 'max' round-trips, both tiers, and the distinctness pin
A2 billed_w(block, policy) -> billed_w(block, POLICY_MAX) +4 B 6 RED
the 'net' and 'sum' round-trips, both tiers, the default, and the pin
B1 add `from . import arbiter as _ab` to app/tariff.py +29 B 1 RED
the import sentence. SHIPPED suite on the same tree: GREEN - the hole.
B2 add `import app.arbiter` to app/tariff.py +19 B 1 RED
the import sentence. SHIPPED suite on the same tree: GREEN - the hole.
B3 add `from .control import compute` (the form the OLD grader DID
catch, as a regression control) 1 RED
C1 delete the ast.Import branch from _imported_modules() 1 RED
names the two spellings it MISSED, so the grader-grader is live
C2 segment match -> substring match (`any(f in m for f in ...)`) 1 RED
names clamps / arbiters / controller as falsely flagged
CONTROL, and the point of the whole ticket: A1 graded by the SHIPPED
test_tariff.py is green, and A1 graded by all 17 SHIPPED suites on a clean
uncontended run is 17 PASS, rc=0. The survivor is real and it is now closed.
ONE THING THE REVIEWER SHOULD KNOW. During the first (contended - two docker
containers at once) run of that 17-suite survivor sweep, test_peakguard.py
reported FAIL once. It has passed 8 times since on the identical tree,
including three concurrent runs and one clean uncontended full sweep, and its
tail was lost to a grep so I cannot say which check it was. I believe it is a
timing-sensitive check under CPU contention and NOT related to this change -
this commit touches no product code and no peakguard fixture - but I could not
reproduce it, so I am recording it rather than asserting it away.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
6ea84a46f6 |
Merge remote-tracking branch 'origin/release/1.0' into TEST-16
checks / unit (pull_request) Successful in 3m41s
# Conflicts: # goodwe_controller/CHANGELOG.md |
||
|
|
20f9f4969d |
TEST-16: pin the two one-sided arbitrage rungs, and un-mask them from each other
checks / unit (pull_request) Successful in 3m51s
SAFETY-26's AC4 gave the same tolerance mutation to every price and quantity
boundary in arbitrage.py and static_tariff.py. Everything in arbitrage.py went
red - `price < 0`, `soc <= floor_pct`, `soc >= ceiling_pct` are each red under
+/-5. Two survived, both in static_tariff.py, and this card closes them.
D `spread == 0.0` (:912) weakened to `spread <= 0.001` SURVIVED at +2 B.
F `len(firm) < 2` (:901) weakened to `len(firm) < 1` SURVIVED at +0 B - the
delta MUTATION.md names as the risky one.
THE DEFECT IS NOT EITHER ROW, IT IS THE INTERACTION. D and F MASK EACH OTHER. A
single firm hour also has a spread of 0.0, so with F weakened the flat rung
refuses the stimulus anyway; with D weakened the small-but-real spread is still
refused, only for a lie. Each rung's failure is absorbed by the other, so BOTH
can be weakened together and a suite grading `kind == "refused"` reports
nothing. That is structurally invisible to single-mutation testing, which is how
this pair came through four rounds of review on TARIFF-03 and FCST-03 - and it
is the arrangement in which the next edit to either rung opens a real hole with
nothing to report it.
D is not cosmetic either. With the tolerance in place a series priced 0.20000 /
0.20050 - a REAL 0.0005 EUR/kWh spread - flips ALLOWED to REFUSED at
min_spread_eur_kwh=0.0, a value arbitrage()'s own docstring documents ("pass 0.0
to mean any positive spread, explicitly") and its validator at :861 accepts on
purpose. At a shipped threshold the outcome does not move, but the operator
reads the false sentence "the tariff is flat - every one of the 2 firm hours
costs 0.2000 EUR/kWh" about a tariff that is not flat.
WHAT WAS ADDED. test_static_tariff.py section 9, and the shape of it is the
argument:
* THE REASON IS GRADED, NOT THE VERDICT. The masked case refuses CORRECTLY
while reporting the wrong sentence, so a check asserting only "refused"
passes on a broken tree. A `rung9()` helper names which refusal answered,
from the sentence the operator would read; an unrecognised refusal reports
itself as UNATTRIBUTED rather than quietly matching nothing.
* EACH RUNG IS GIVEN A STIMULUS THE OTHER CANNOT ABSORB, or the pinning is
circular. The flat rung gets a THREE-firm-hour flat series, which no
`len(firm) < N` a person would write can reach. The firm-pair rung gets a
ONE-FIRM-HOUR series, which the flat rung CAN reach - so its attribution is
the whole check, and that is why it is written as a rung name rather than a
verdict.
* AC1 is a sweep of small-but-real spreads (0.0005 down to 0.000001) all
ALLOWED at min_spread_eur_kwh=0.0, with the exactly flat series on the other
side still refused BY THE FLAT RUNG - without that mirror the sweep would
also pass for a rung deleted outright. 1e-6 is the floor because the shipped
line rounds the spread to 6 decimals; that quantisation is graded in the
open as its own row rather than left unstated.
* AC3 is a five-row table graded on rung attribution, which denies the masking
from both sides at once.
* The firm-pair count is also pinned from ABOVE (`< 3`) and BELOW (`< 0`),
which the criteria do not ask for but which is what stops this section being
one-sided in exactly the way it was written to fix.
EVIDENCE. Eight rounds through TEST-15's tools/mutation_run.sh, used UNCHANGED:
recursive __pycache__ purge before each run, python3 -B, the tree re-copied FROM
DISK between rounds, the mutated line grepped out of the file before the run,
byte delta printed, test_static_tariff.py and test_arbitrage.py graded each
time. Baseline green.
baseline, shipped +0 B PASS
D1 `spread == 0.0` -> `<= 0.001` +2 B RED, 3 checks
D2 `spread == 0.0` -> `<= 0.000001` +5 B RED, AC1 alone
D3 `spread == 0.0` -> `< 0.0` (rung gone) +0 B RED (section 2 as well)
F1 `len(firm) < 2` -> `< 1` +0 B RED, 3 checks
F2 `len(firm) < 2` -> `< 3` +0 B RED, 6 checks
F3 `len(firm) < 2` -> `< 0` (rung gone) +0 B RED (ValueError)
D1+F1 BOTH AT ONCE - THE TICKET +2 B RED, 5 checks
Four of the seven are +0 B, the delta MUTATION.md names as the one stale
bytecode can hide. All are REDS, the direction that defect cannot fabricate -
but they were run under the purge anyway, because "it went red so the cache
cannot have lied" is a conclusion and not a procedure.
NO SHIPPED BEHAVIOUR CHANGED. app/ is untouched; both rungs were correct all
along, and the card is explicit that a rung found actually wrong is a stop-and-
report rather than an edit. Also updated: MUTATION.md gains a short section on
masking as a SECOND way a survivor lies, with the two rules that fall out of it
(grade the reason, and mutate suspected pairs together); and test_arbitrage.py's
SAFETY-26 AC4 note is marked closed rather than left reading as an open finding.
UNSURE ABOUT. The 5e-7 row asserts the shipped `round(spread, 6)` quantisation.
That is a real property of the line and worth stating, but it does pin a
rounding the ticket never named - if a reviewer would rather that stayed
unpinned, it is one check to drop and nothing else depends on it.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
d0b053b150 |
TEST-10: pin max_w beside the meter_freeze_s key TEST-06 already pinned
checks / unit (pull_request) Successful in 3m43s
max_w and the LIVE_MAX_W literal beside it were the two survivors left
after TEST-06 pinned meter_freeze_s: changing max_w 2000 -> 4500 in
config.yaml passed every check in test_freeze.py and test_tariff.py
GREEN, and LIVE_MAX_W = 5000.0 was a bare literal that silently
disagreed with the shipped max_w (2000) with nothing in the file
saying so. For contrast, deadband_w 15 -> 5 already went RED 2 + 1,
so the pinning technique was known to work - it just was not applied
to the key either side of it.
Three changes, each measured:
1. test_freeze.py gains a check comparing Tuning()'s code default
(control.py, 2000.0) against SHIPPED_MAX_W, read from config.yaml
by extending the file's existing _cfg_default() regex reader
rather than reimplementing test_arbitrage.py's _shipped. Broken
and confirmed red: max_w: 2000 -> 4500 in config.yaml now fails
exactly "the code default and the shipped default agree on max_w
too" and nothing else in either file; reverting returns both files
to all-green. (AC 1, AC 4)
2. LIVE_MAX_W is renamed LIVE_INSTALL_MAX_W in both test_freeze.py
and test_tariff.py, each with a comment stating plainly that 5000
is the live install's own override, not config.yaml's shipped
max_w (2000) - the defect was a literal that could be misread as
the shipped default, not the number itself. (AC 2)
3. test_freeze.py states PINNED_KEYS = ("meter_freeze_s", "deadband_w",
"max_w") in one place as the complete set of config keys this
suite pins. Deliberately excludes maintenance_* - CFG-03 (merged
into release/1.0 since this branch started, merged in here) gave
those keys a separate single source of truth in app/maintenance.py
and this ticket has no reason to duplicate that pin. Not every key
in config.yaml is pinned here on purpose: meter_freeze_s,
deadband_w and max_w are the three this file's mutual-exclusion
arithmetic (section 2b) actually reasons about together. (AC 3)
Full 17-file suite run green under goodwe-addon-ci after the merge
with release/1.0 (
|
||
|
|
d5b1ef19b3 |
CFG-03: give maintenance option defaults one source of truth
checks / unit (pull_request) Successful in 3m44s
Option defaults for the maintenance cycle were declared in three places that
could disagree, and MAINT-04 proved they already did. config.yaml shipped
`maintenance_charge_w: 2000`; main.py carried TWO `opts.get(..., 2500)`
fallbacks; MaintConfig's dataclass carried a third `2500.0`. So an options dict
with the key ABSENT was ACCEPTED by validate.py's rule 6 - which read 2000 -
and then built by main.py at 2500, against a 2000 W ceiling:
options dict with maintenance_charge_w ABSENT, max_w=2000
validate_startup_config -> [] (accepted, no problems)
MaintConfig().charge_w -> 2500.0
arbiter.resolve() -> 0.0 W, contradiction=True
That is the bug rule 6 exists to refuse, passing rule 6. It is unreachable on a
Supervisor install, which always supplies every key from config.yaml, and fully
reachable from sim/inject.py and from the test suite - which is where anyone
debugging maintenance actually works.
MAINT-04 shipped a TRIPWIRE and said so: test_validate.py pinned all three
literals and asserted the consequence through the real arbiter, so the
divergence could not silently widen or be half-closed. Its PASSING CONDITION
WAS THE BUG. Both it and validate.py's comment said to delete each other when
the divergence was closed. It is closed, so both are deleted.
THE DIVERGENCE WAS WIDER THAN ONE KEY. `maintenance_discharge_w` had the
identical three-way split (config.yaml 2000, MaintConfig 2500) and the card
named only the charge side. Closing one and leaving its twin would have
satisfied the numbers and left three sources of truth one line down, which is
the state that produced the bug. Both are closed, and so is the whole family:
all eight `maintenance_*` keys go through the same mechanism.
WHAT THE SINGLE SOURCE IS. config.yaml's `options:` block - it is what the
Supervisor reads and what the operator edits, so it wins by definition. There
is now exactly one in-code copy, `maintenance.MAINT_OPTION_DEFAULTS`, which is
TARIFF-02's `PRICE_OPTION_DEFAULTS` and SAFETY-24's `PEAK_OPTION_DEFAULTS`
pattern applied to the family that named the card - validate.py's rule 8 comment
already called that "CFG-03 read as a rule rather than as a complaint", so this
makes the rule hold where it was first broken rather than inventing a fourth
mechanism for one option family.
A MIRROR RATHER THAN A RUNTIME READ, and the reason is mechanical: the
Dockerfile copies `app/` and `run.sh` into the image and NOT config.yaml. The
running add-on cannot open the file it is configured by, so there is nothing to
read at 03:00 on a client's Pi, and a YAML-subset parser that could fail at
import is a new way for the add-on not to start. What makes the copy safe is
that test_maintenance.py pins every entry by READING the shipped file - drift is
a CI failure, not a comment.
EVERY OTHER SITE NOW DERIVES FROM IT OR HAS CEASED TO EXIST:
* MaintConfig's eight dataclass defaults are indexed out of the mirror. No
numeric literal survives in the class that held the third opinion.
* `MaintConfig.from_options()` is the ONLY place in the add-on that reads a
`maintenance_*` option. main.py's eight inline `opts.get(key, <literal>)`
calls are gone: moving the read next to the mirror means the fallback cannot
be anything but the mirror, because there is no literal in sight of it to
disagree with. It uses `key in opts` rather than truthiness, so a shipped
`false` or `0` is honoured instead of being quietly replaced by the default
- this card's own bug in a different costume.
* main.py's SECOND fallback site - the cheap-window charge floor at the
P_MAINT_SHAPE claim - reads `self.maint.cfg.charge_w` instead of re-opening
the options dict with its own literal. The Controller had already parsed
this once in __init__; asking the object that owns it cannot drift from it,
and the rate the shaping asks for can no longer be a different number from
the rate the state machine drains at on the same install.
* validate.py's rule 6 and its `maintenance_discharge_w` warning take their
fallbacks from the mirror.
WHERE THE RANGE LIVES, STATED AND CHECKED. config.yaml's `schema:` block carries
`maintenance_charge_w: int(500,5000)` - a fourth declaration site of a different
kind. It is a BOUND, not a default, so it is not this bug; but leaving the
question open is how a fifth site arrives. The decision recorded in config.yaml
and in maintenance.py is: bounds live in the schema block ONLY, because the
Supervisor is what enforces them and the Supervisor reads only that file, so a
Python copy of `int(500,5000)` would be a place to disagree and nothing else.
test_maintenance.py checks both halves of that: every mirrored key must have a
schema entry - without one the Supervisor drops the option and the add-on
silently runs on the mirror instead of the operator's value - and every shipped
default must lie INSIDE its own range, since a default the schema rejects is a
config that cannot be re-entered once it is edited. What the schema grammar
cannot express is a relation BETWEEN keys (`maintenance_charge_w` against
`max_w`), which is exactly why rule 6 is written in Python and why it does not
belong in the mirror either.
THE REPLACEMENT CHECKS, AND HOW THEY WERE VERIFIED. test_validate.py's new
section exercises the same four consumers the defect ran through, the same way:
the validator ACCEPTS a dict with every maintenance key missing; a REAL
Controller built from that same dict holds 2000 W (through main.py, not through
a regex over its source); `MaintConfig()` answers 2000 W with no dict at all;
and the real arbiter emits `-2000 W, limited by supervised(max_w)` instead of
`0 W, contradiction=True`. test_maintenance.py pins the mirror to config.yaml in
both directions - equal values, and full coverage of every `maintenance_*` key
the file ships, so a ninth key cannot arrive unmirrored - and asserts the
consumers move as a RELATION rather than against numbers, reading MaintConfig's
defaults back out of `dataclasses.fields()`.
Each new check was verified by BREAKING the thing it watches and observing red,
this project's rule:
1. config.yaml -> 1500, mirror left at 2000: test_maintenance 1 FAILED,
test_validate 4 FAILED.
2. config.yaml AND the mirror -> 1500: green again, and every consumer moved
together - MaintConfig() 1500 W, the Controller 1500 W, and the arbiter
`-1500 W, limited by maintenance(cheap-window charge)` where it had said
`-2000 W, limited by supervised(max_w)`. That is AC4: change the single
source and watch the consumers follow.
3. `charge_w: float = 2500.0` retyped into the dataclass: 2 FAILED in each of
the two files.
4. `opts.get("maintenance_charge_w", 2500)` restored in main.py: 1 FAILED,
naming the file and the literal it found.
5. `maintenance_hold_min` deleted from config.yaml's options block: 3 FAILED.
Full suite 17/17 in goodwe-addon-ci, twice, once under parallel load.
Stale prose that asserted the now-closed divergence as current is corrected in
app/watchdog.py, test_watchdog.py and test_peakguard.py - watchdog.py's example
still uses 1500 W, but because the point of the example is a charge strictly
inside the ceiling, not because 2500 is what ships.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
e498dd4c1c |
SAFETY-25: pin the claim-source set, so the tripwire is one
checks / unit (pull_request) Successful in 3m53s
The durability claim this PR shipped was FALSE, and the reviewer of #31 disproved it by building the fix. Part 10 said, in four committed places, that it "goes RED the day a loop-side floor is built, so the exposure cannot change size under a green suite". The reviewer implemented the memo's own recommended Option B in main.py - a `Claim.limit("reserve", P_LOOP, hi=0.0)` filed under a `loop_soc_floor` - and the ENTIRE SUITE STAYED GREEN. Part 10 green. Mutation 13 went on printing "NOTHING PREVENTS IT, ON PURPOSE" and the same 21 % -> 10.0 %, on a tree where something DID prevent it. Pushed to an absurd always-binding 95 % reserve it was caught only by SAFETY-24's pre-existing part 7 wiring checks; part 10 was still green. THE CAUSE IS STRUCTURAL, not a missing assertion. `replay_loop()` hand-builds main.py's claim list as a literal `[supervised, loop, peakguard.claim(...)]`, so it is blind to any claim main.py ADDS - which is exactly where AC 2 would be built. That is this repository's named failure mode: a check that observed something other than what it claimed to observe, shipped as a guarantee inside the document that recommends the change. THE FIX IS 10f: THE CLAIM-SOURCE SET, PINNED, two ways because the two fail differently. * STATICALLY, over `Controller.cycle()`'s own AST. Every `claims.append(...)` in it must be one the scan can read - an unreadable append FAILS rather than counting as nothing, which is how a scan like this goes quietly vacuous - and the sources it can file must be exactly {device, supervised, failsafe, safety, peak, arbitrage, maintenance, loop}. A ninth takes part 10 red on the line it is written, in every configuration, whether or not any fixture here reaches the state that files it. * DYNAMICALLY, through REAL `Controller.cycle()`s with main.py's OWN `resolve` spied - not a list this file built and hoped matched - swept over the WHOLE 0..100 % SoC range in the two states 10a-10c replay. Idle: exactly {device, supervised, loop}. Floor-limited: exactly {device, supervised, loop, peak}. A claim conditioned on a low pack, which is the shape a loop-side floor has, cannot hide from a sweep that visits 0 %. And the fold is checked rather than assumed: main.py's two P_SAFETY rating limits are both symmetric LIMITs, so replay_loop() modelling them as one `supervised` claim at the tighter bound is exact. MEASURED AGAINST THE COUNTEREXAMPLE. Reproduced first on the unfixed tree (green, as reported). On this tree the reviewer's Option B at its recommended default takes part 10 RED on 3 checks, and the 95 % variant on 6. Nine mutations were run in all, each against a freshly copied tree with no `__pycache__` present, mounted `:ro`; all nine red, no survivors, no `+0 B` delta. MUTATION.md records why a second round was needed: the first round's mutations were all aimed at DISARMING the guard, while the claim part 10 actually made was about the guard being FIXED. The four false sentences are replaced with what is now true, and each says WHICH half catches WHICH shape - 10f for an arbiter claim (Options B and C), 10a-10c for a clamp inside control.compute() or the guard (Option D), which the replay drives directly. AC 2 IS STILL OPEN AND NOTHING HERE BUILDS IT. The loop-side floor was a test mutant, reverted before commit. The memo still says "Status: OPEN. This is a memo, not a decision." Also, non-blocking, from the same review: the NOT READY banner had inherited the new scope sentence and become a ~550-character paragraph that the row three lines below repeated verbatim. A checks() row may now carry an optional short `banner` form; the floor-limited row does, and `status_payload()` prefers it. THE ROW IS UNCHANGED - shortening that would have been weakening AC 3 - and rows without the key are unaffected. Graded, and mutated: dropping the short form goes red. Merged origin/release/1.0 first (CI-02), keeping both tickets' CHANGELOG entries. Full suite green: 17/17 in goodwe-addon-ci (test_ci_gate.py needs `git`, which CI-02 added to .gitea/ci/Dockerfile but the local image lacks; run with it installed and it passes). Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
3cb9d3b7d9 |
Merge origin/release/1.0 into SAFETY-25
CI-02 landed on release/1.0 after this branch was opened and both tickets add a block under `## Unreleased`, so CHANGELOG.md collided. Both entries are kept, newest-first: SAFETY-25's, then CI-02's, then SAFETY-20's. Nothing else conflicted. |
||
|
|
29fa39eda7 |
Merge origin/release/1.0 into SAFETY-20
checks / unit (pull_request) Successful in 3m36s
# Conflicts: # goodwe_controller/CHANGELOG.md |
||
|
|
7b4877d56d |
TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran, and reported the mutation as a survivor. It was not one. CPython validates a cached `.pyc` on (source size, source mtime truncated to whole seconds), and that edit moved neither number - same length, same second - so the interpreter loaded the bytecode it already had. Disassembly settled it at the time: the source read `here`, the running code loaded `self`. A mutation run had graded code that was not there, with no error and exit status 0. This does not make the results already on the record wrong. It makes them UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a campaign and nothing here quietly assumes the old numbers hold. REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two return values are the same length, imports it in a real subprocess, rewrites it inside the same second (retrying until both writes land in one whole second - milliseconds, no sleep) and reads back which value ran. Part 1 shows the interpreter running SELF off a file that says HERE. AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only. Neither stops an EXISTING stale .pyc being read, and a mutation run always has one, because the previous run wrote it. Part 2 grades both still running the old code. The advice in test_control.py's coverage audit led with `-B`; it is corrected here - the purge is the half that works, and `-B` earns its place by keeping THIS run from leaving a cache for the NEXT edit to inherit. NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy. Waiting it out would slow every run down and would still only cover the edit somebody remembered to slow down. THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of every app/*.py it is about to grade - so a mutation report can say WHICH source produced it, which is the reviewer's addition to this card - runs each suite under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's reason), and fails if a cache appears during the run. It takes the tree as an argument so the infra repo's replay harnesses can call it without being moved. WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement, the reporting rules and the survey, and every one of the 16 suites now points at it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py part 5, so a new suite that joins this directory without the pointer is red - the same failure shape CI-01's file glob exists to prevent. CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit status 0 - while the same probe on a writable mount produces one. Each job also rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the `:ro` is one character wide and the next person debugging a write will be tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the file - the first draft searched the whole workflow and stayed green after the flag was deleted, because the comment explaining it still named it. THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed: goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was written. There is no deploy-side finding. THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is one-directional - a mutation that never took leaves the suite green, so stale bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every "all red, no survivors" claim in the window out of scope, along with mutations executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where no source file is edited) and everything run after the purge discipline landed on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is the recorded SURVIVORS from source-edit runs before that date. Two were re-run here under the harness and both still stand: TARIFF-01's record_block() ignoring its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green each, on the tree as it stood. The rest are labelled still-unverified rather than assumed or re-run; each is one harness run to close, and the moment to spend it is when somebody next touches that module. OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today), so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes a tree argument for exactly that, but the change belongs in that repo and some of those harnesses want the rig. RED AND GREEN. Every new check was broken and watched fail: the purge commented out of the harness turns part 4 red (and its non-vacuity probe already proves the fixture would mis-grade without it); one docstring pointer removed turns part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow turn part 6 red. Full suite green, 16 files, in the CI image on a read-only mount - the shape the runner uses. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
504e8daac3 |
TEST-17: grade the status page's peak row at a stated month, not at today's
checks / unit (pull_request) Successful in 3m35s
release/1.0 went red at 00:00 on 2026-09-01 on a commit nobody had touched. `Controller.checks()` read the capacity-tariff peak with `self.peak.peak()` - no argument - so tariff.py resolved the month from `datetime.now()`, while test_tariff.py section 10 banks its quarter at the fixed fixture 2026-08-30. From 1 September the page was correctly asked for September, correctly answered NO_RECORD, and the row read "no completed quarter recorded yet" - a string containing no "peak", which the section's own filter required. Four checks failed. ISOLATED BY MOVING ONLY THE CLOCK. Same commit, same shipped-deps image, libfaketime: green at 2026-08-30, four failures at 2026-09-01. Identical at |
||
|
|
04292c4a08 |
DATA-01: thirty days of the real meter, and what AC 3 actually measures
checks / unit (pull_request) Successful in 3m36s
TARIFF-01 and SAFETY-07 both merged with AC 3 - "monthly peak held under
the soft limit in >= 95 % of intervals over a 30-day simulation replay" -
honestly unmet, because two days of capture existed and it was believed
nothing longer could be produced. That belief was a true statement about
the past read as a claim about the future: HA's recorder still held the
whole month, and the reason nobody found out is that the 2026-08-25
export was a one-off script that left no artefact.
So the exporter is committed and runnable now.
scenarios/p1-net-30d-2026-08/ is 2026-08-01 to 2026-08-30, 485,841
samples, 30/30 days read, 0 failed, 4.13 MB gzipped, in the schema the
two committed days already fixed.
VERIFIED AGAINST THE DAYS THAT EXIST. `--verify` re-fetches 2026-08-20
and 2026-08-23 by this exact route and reproduces both committed files
BYTE FOR BYTE after decompression (865,024 B / 15,600 samples and
894,387 B / 16,351 samples). The gzip containers differ by design: this
exporter writes mtime 0 so its output is reproducible, where the one-off
wrote a wall clock.
A FAILED READ IS NOT AN OBSERVATION. A day whose read fails writes no
file, is recorded "read": "FAILED", and the run exits non-zero; the
entity is proved to exist through /api/states before any empty day is
believed, because a typo would otherwise answer 200 [] thirty times and
produce a consistent dataset of nothing. Nothing is interpolated, so the
month's 13 gaps (1291 s, 99.95 % covered) and its 3 `unavailable`
samples stay visible as holes.
SIZE: COMMITTED, DELIBERATELY, AND MEASURED. A git bundle of the whole
history goes from 1.58 MB (release/1.0 @
|
||
|
|
d57122ec74 |
DATA-02: a real Belgian price year, so AC4 stops being unmeetable
checks / unit (pull_request) Successful in 3m36s
OPT-04 reported AC4 - "net-positive across 12 months of replayed prices" - as NOT MET and replayed a synthetic year, because scenarios/ held only P1 meter captures. Right call, wrong diagnosis: the criterion was being carried beside a 30-day METER criterion as though both needed waiting. EPEX BE day-ahead is public data, not a capture. It needed a fetch. 8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, canonical three fields. Licence checked BEFORE committing: Energy-Charts publishes the BE zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under private-use-only terms, so this one is redistributable with attribution. The fetcher refuses to write a file whose per-response license_info stops saying so. Cross-checked against SMARD's own 4996/DE: 96 of 96 quarter-hours, max difference 0.00 EUR/MWh. Raw wholesale, and the file says so. all_in: false, with the markup/tax assumption carried as numbers to APPLY rather than numbers applied - TARIFF-02's trap in data form. Section 7B applies it in one visible place and asserts arithmetically that its additive terms cancel out of every daily spread, so the trade count turns on the VAT multiplier alone; the raw replay is run too, so how much rests on the guess is reported (110 vs 88). DST by construction: iterate in UTC, render through price.brussels(). 2025-10-26 is 25 points, 2026-03-29 is 23, verified by counting per Brussels day rather than asserting 24, and by checking October's 02:00 appears twice at two offsets with two prices while March's never appears. Both bugs the point-and-gap accounting caught were real: a UTC-bounded window made the first day 22 hours, and an inclusive-end off-by-one dropped the last day silently. A day nobody asked for is not a day with no prices. THE RESULT, AT THE SHIPPED DEFAULT, WHATEVER IT IS. At 0.10 widened 1.5x to 0.1500: 110 round trips, +24.88 EUR net of the cycle cost. Unwidened, 173. Nothing tuned - the threshold and the 2.5/1.5 factors are untouched. And what the owner's decision now has under it: the four reports that a static ~0.0840 spread does not clear 0.10 all STAND. What was missing is that a dynamic site clears the widened requirement on 121 of 365 days, median all-in spread 0.1130, so a median day would clear at 0.0754 - 156 trips, +35.42 EUR. Reported, not applied. The synthetic year stays, because the real one cannot grade section 17: not one of 365 days has a negative DEAREST hour, so a zero there counts something that could not happen. 7B asserts that degeneracy rather than reporting the zero. Size measured, not assumed: 893 KB plain but 74.6 KB as a git object against 56.5 KB gzipped. Git already compresses; 18 KB is not worth making the provenance block - the licence claim a reviewer must check - unreadable in a diff. Nothing wired into the add-on; generic_dayahead is still the live path. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
9234016419 |
Merge release/1.0 (OPT-04) into SAFETY-24, and fix one grader the merge broke
checks / unit (pull_request) Successful in 3m36s
OPT-04 landed after the previous rebase. Conflicts were CHANGELOG.md and one IMPORT LINE in validate.py; both refusal blocks and both option sets survive untouched, and DOCS.md, main.py and config.yaml auto-merged. ⚠️ AND THE MERGE BROKE A CHECK THAT NEITHER CARD COULD HAVE SEEN ALONE. test_peakguard.py graded "the first `.decide(` call in main.py" and asserted there was exactly one. That was true when SAFETY-24 was written; OPT-04 added `arbitrage.decide(...)`, so the merged tree had two and the assertion failed. It failed loudly rather than grading the wrong call - the guard did its job - but it cannot ship red. Fixed by selecting the call by QUALIFIED NAME (`peakguard.decide`) instead of by position, and requiring exactly one of THAT. Other modules may now call their own decide(); this grader can no longer be moved by one of them. Verified still discriminating: a decoy `peakguard.decide` added to main.py turns it red on 7 assertions, and the `maintenance_soc_floor` swap still turns it red on 6. Also folded in the review's wording finding. An assertion read "a CONTROLLER whose SoC entity does not answer hands decide() None" while driving no Controller. The wiring property is stronger than the one claimed, and is now asserted on the SERVICE CALL: a Controller with no SoC never reaches the guard at all, because `inputs_ok` is False and cycle() stops at the safety claim first - so a `float(soc or 100)` defaulting line above the call site cannot disarm the floor. The original decide()-level check is kept, reworded to say what it actually grades. Full suite green on the merged tree: 15 files. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2b8b8cb97f |
SAFETY-26: pin the negative-price refusal from below, not only from above
checks / unit (pull_request) Successful in 3m15s
OPT-04's reviewer weakened `if price < 0` to `if price < -0.001` and every suite stayed green while a -0.0005 EUR/kWh sell hour discharged. The shipped code was right the whole time; the CHECK could not tell correct from nearly-correct. The only probe near the boundary sat at 0.0000, which catches a `<=` and says nothing about a tolerance invented on the other side - and a tolerance on the other side is §17's named regression walking through with the suite passing. A dearest hour at -0.0005 is an ordinary Belgian day-ahead print, not a fuzz value. `app/` IS NOT TOUCHED. `if price < 0` is already correct and changing it would be the defect; this card closes the check, not the behaviour. The 0.0000 probe stays and is now labelled as the half that pins the boundary from above. The new probe is a SWEEP rather than a point, because one probe at -0.0005 closes `-0.001` and nothing else - a mutation reaching for `-0.01` would be the identical defect one decimal further out. Five prices span four orders of magnitude down to -0.000001, the last place the canonical six-decimal format can express; each is asserted to survive that rounding as strictly negative, to still be the DEAREST hour, and to still clear the widened threshold, so §17 is the only rung that can refuse. The same five magnitudes with the sign flipped all discharge, so this is a boundary at exactly zero rather than a refusal of small numbers. AC4, the look: every price/quantity boundary in arbitrage.py and static_tariff.py was given the same tolerance mutation, both directions where both exist. Two survive, both in static_tariff.py and both NAMED RATHER THAN FIXED - they are TARIFF-03's rungs and want probes in its own file. `spread == 0.0` loosened to `<= 0.001` flips a real 0.0005 spread from allowed to refused at min_spread_eur_kwh=0.0, a documented supported value, and otherwise prints a false reason about a tariff that is not flat. `len(firm) < 2` loosened to `< 1` survives at +0 bytes - TEST-15's risky delta - and is masked only by the flat rung, so the two mask each other and a later edit to either opens a hole nothing reports. Mutation verified under `python -B` with a recursive __pycache__ purge, byte delta printed (+5 B), the mutated line asserted changed, and - per the reviewer's addition to TEST-15 - the tree re-read from disk and asserted to be the tree that was mutated before each run. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
bdd7f18a54 |
OPT-04: charge cheap, discharge expensive - and only when it pays
checks / unit (pull_request) Successful in 3m16s
Four cards built the price stack and nothing traded on it. app/arbitrage.py is §10.1's priority 3, and it consumes all four rather than re-deciding anything: whether a trade is permitted at all, on which two hours, against which widened threshold is TariffPlan.arbitrage()'s answer, and that answer cannot be obtained without first saying whether the peak guard is holding. §9.1's "peak shaving outranks arbitrage" is therefore honoured structurally - there is no path to a spread that skips the question - and again in the arbiter, where P_PEAK (50) clamps a claim filed at P_ARBITRAGE (30). A guard that never ran is not a guard that is clear. On meter_source off the peak guard is never evaluated; that third state is carried as None and refuses, because charging at the rail creates the billed quantity while nothing measures the quarter. validate.py refuses that configuration too, along with arbitrage armed with no price source and a SoC floor at or above the ceiling. §17: never export into a negative price. The guard is on the hour being sold into, not on the spread - a day priced -0.30 .. -0.05 clears any threshold and its dearest hour is still negative. Buying in a negative hour stays allowed. resolve_tariff() may open an HTTPS connection and the tick feeds the ESP32 heartbeat, so the fetch runs in its own task at a 30 min cadence and the tick reads an attribute and an age bound. test_arbitrage.py section 8 asserts that structurally on the shipped AST: a fetch put back on cycle() is red. AC4 is NOT met and is not restated - this repository holds no price history. Section 7 replays a synthetic year and asserts the property that does not need real prices: every executed round trip cleared its own widened requirement, and zero discharges landed in the 522 negative-priced hours. At the shipped 0.10 EUR/kWh threshold a realistic Belgian day/night site does not trade at all. Reported, not tuned: that number and FCST-03's widening factors are one product decision and it is the owner's. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
a1376e44e4 |
Merge release/1.0 (FCST-03) into SAFETY-24 - CHANGELOG only
checks / unit (pull_request) Successful in 3m28s
FCST-03 landed while this was in review, so both branches had prepended an Unreleased stanza. Only CHANGELOG.md conflicted, exactly as predicted; app/, config.yaml, validate.py and DOCS.md all auto-merged, and this card touches neither price_forecast.py nor static_tariff.py. Both stanzas kept verbatim, SAFETY-24's above FCST-03's - no text from either author edited. Full suite green on the merged tree: 14 files. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e709554857 |
SAFETY-24: an energy floor under the peak guard's forced discharge
checks / unit (pull_request) Successful in 3m29s
SAFETY-07 can command a discharge to hold a billed quarter down, and nothing below it consulted the state of charge. On the 2026-08-20 replay it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a real floor and it works - but it is the pack's protection rather than the operator's, and a month of aggressive quarters leaves the battery repeatedly at that cut-out with no EMS-side record of why. The first symptom is a pack never available when wanted, which is indistinguishable from the SoC drift MAINT-01 exists to correct. decide() now takes soc and soc_floor, both required and neither defaulted, and discharge_permitted() is the one place the question is answered. Above the floor nothing changes. At or below it the guard files a 0 W floor instead of a sized one - one-directional, so charging stays blocked and no discharge is capped - and reports floor_limited with the reason it bound. It is not a trip: every stop in 11.2's table still outranks the claim, and the floor is never negative, so 9.1's asymmetry survives as a property of the object (0 negative floors over 1296 swept combinations, SoC included). The SoC is graded only after `wanted > 0` is established, so it is never evaluated where it governs nothing. An unreadable SoC is floor-limited, not a full battery - a full battery is exactly the value that would disarm the floor, and this project shipped that defaulting once already. Failing to shave is not silent: one notification per episode (goodwe_peak_soc_floor), distinct from the saturation alarm because the two ask for opposite operator actions, plus its own status row and an action-log line. Verified by replay. The 2026-08-20 capture is driven against a modelled pack sized from the day's own measured appetite, so it genuinely exhausts: without the floor it reaches the BMS cut-out and holds there for 1227 guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The energy withheld equals the energy between the two floors to within one cycle at the rail. The honest half is reported too - the worst quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less on purpose. Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS (TARIFF-02's pattern), imported by validate.py and main.py rather than typed as literals and pinned to config.yaml by a check that reads the file - so CFG-03 still tracks three places. validate.py rule 8 refuses peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner. maintenance_soc_floor is deliberately not reused and not renamed: it is a drain target, not a spend limit, and the rename is recorded as a decision to revisit if a third floor appears. Eleven mutations of the shipped source were run against the checks; all eleven go red and there are no survivors. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
71cd7849e4 |
Merge release/1.0 (SAFETY-07) into FCST-03, and close two degenerate stimuli
checks / unit (pull_request) Successful in 3m13s
CHANGELOG.md was the entire collision - SAFETY-07 lands in peakguard.py, main.py and the arbiter, none of which this branch touches. Both entries kept. X1. `_firm_or_die` guarding only `cheapest` survived, because the check passed the SAME provisional point as both cheapest and dearest: a guard on either role alone raises, so the stimulus could not tell "the buy hour is guarded" from "both are". Now one call per role with a firm point in the other seat, plus the positive arm so the two refusals are discriminating. X6. `firm_points()` returning the carried hours too survived, because its two consumers - the §11.4 refusal and cheap_now - guard provenance independently and both keep answering correctly. The accessor is now graded directly: exactly the published points, by identity and in order. Both are the degeneracy rule this file states at the top, in a new dress - a stimulus that cannot distinguish the two things it grades. ⚠️ AND THE REASON THE M9 MUTATION "SURVIVED" IN MY EARLIER REPORT: a stale __pycache__. Reverting `self.provisional` to `here.provisional` changes neither the file size nor, at one-second resolution, the mtime, so CPython kept the MUTATED bytecode and a green run afterwards proved nothing about that line. Every mutation here now clears __pycache__ first; re-run that way, M9 is caught. The committed source was always correct - the checks were not being run against it. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
dd40c56ab4 |
FCST-03: yesterday's prices, flagged as yesterday's, and unable to move anything
checks / unit (pull_request) Successful in 2m43s
§8.3 fills the hours a day-ahead feed has not published yet with yesterday's profile and flags them provisional, and forbids any irreversible action on such a price. The whole risk of this ticket is one line - a carried point and a published point are three fields and a bool, so `provisional=y.provisional` copies yesterday's False onto today's guess and produces stale data presented as current. That is SAFETY-18's frozen-but-fresh meter one layer up. So the flag is never passed through. Carried points come from a constructor with no provisional parameter; published points pass through BY IDENTITY, so no copy exists that could lose one; an audit re-derives the expected flag for every emitted point and raises rather than repairing; and the check walks the module's own AST so the pass-through idiom cannot come back looking ordinary. A published point may itself be provisional (eneco_eddy's imbalance print is), so the rule for a published hour is "whatever the feed said", never False. The fill keys on the Brussels wall clock rather than t-24h, so the 23- and 25-hour days are right; a late publication rebuilds the series, moving the number and the flag together. AC2 and AC3 landed on TARIFF-03's existing verdict surface rather than beside it. Refusal 3 became "fewer than two FIRM hours" - refusing on "any point is provisional" would have switched arbitrage off every morning on every dynamic site - and refusal 5 is new: the spread must clear a threshold widened by the widest active uncertainty source (max, never a product). The permitting variant now refuses to be constructed around a provisional point at all, and the cheap-window flag became per-hour for the same reason. The irreversible action is a value carrying the hours it commits, derived from maintenance.py's own DRAIN_TIMEOUT_MIN; the gate blocks a maintenance drain whose window reaches into a carried hour, and the phase machine stays idle. It is the price-justified entry point only - a gate that blocked on no_data would stop the monthly cycle on every default install. Zero new config options; TEST-14's signature scan ported to cover both Gate's and Arbitrage's constructors, closing _Refused.reason's open hole. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c2ed509565 |
Merge release/1.0 (TARIFF-03) into SAFETY-07
checks / unit (pull_request) Successful in 3m12s
The anticipated conflict again, and only it: both cards prepend to CHANGELOG.md's Unreleased section. Both entries kept, SAFETY-07 first. app/main.py and DOCS.md auto-merged, so the overlap claim on #18 still holds - config.yaml and validate.py remain untouched by this card even after TARIFF-02 and TARIFF-03 widened both. Full suite green on the merge result, test_price.py and test_static_tariff.py included. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2d570d84ce |
SAFETY-07 review: defend the three wiring mutations that survived
The reviewer's finding was correct and the shape of it matters: everything the
first cut graded was in peakguard.py, and grading the module is not the same as
grading the guard. Three one-line changes to main.py's CALL SITE left all twelve
suites green while a default install parked at 0 W in the quarter that sets the
month's bill.
B2 was the serious one. My own comment described that defect - "that entity is
optional and empty on a default install, so until now the suspension could not
fire on the site that needed it" - and nothing could regress it. A comment that
documents a fix nobody can test is the same shape as a corrected comment nobody
tests, which this project has already been caught by once.
WHAT CHANGED
The suppression conjunction moved out of main.py and into
peakguard.shaping_suspended(), for the reason watchdog.loop_is_following() and
freeze.looks_frozen() live where they do: the check that grades a safety
predicate must assert on THE SHIPPED EXPRESSION, not on a transcription that can
drift apart from it in silence. Its docstring carries both terms and why neither
is sufficient alone. main.py's call site now says READ THAT FUNCTION FIRST, and
records that a reviewer mutated it back to its historical broken form with every
suite staying green.
test_peakguard.py part 7 gains a section that EXECUTES the three mutations
rather than describing them. Each one is put in place on the shipped module and
the REAL Controller.cycle() is driven with it, on the dangerous fixture: a
default install (no peak_forecast_entity, so peak_fc is None and peak_at_risk is
False forever) with maintenance in its CHARGE phase, so a P_MAINT_SHAPE `hi <= 0`
limit is live, and the guard genuinely engaged on the measurement. That the
mutations are monkeypatched onto the shipped module is itself load-bearing: if
main.py inlined either expression again the patch would do nothing and these
checks would pass vacuously.
SHIPPED suspended=True loop -> 1498 W, limited by peak +1497.8 W
B1 suspended=False CONTRADICTION between limits 0.0 W
B2 suspended=False CONTRADICTION between limits 0.0 W
B2b (forecast term dropped instead) - caught by its own check
B3 is graded three ways, because the single-cycle form is only INFLATED and the
failure is what happens on the next cycle:
* the value main.py actually hands decide() is recorded off the real call, with
the measured battery at 0 W and the command standing at +3000 W;
* the one-cycle difference is asserted to be exactly the standing command - the
whole defect in one line, watts that were asked for and never arrived counted
as if they had;
* both forms are then run forward against the REAL controller's own projection
with an inverter that never follows:
intent-sized floor 4482 5000 5000 5000 ... SATURATED at cycle 2
delivered-power floor 1482 1482 1482 1482 ... stationary
* and the call site is graded on parsed syntax, so a rename cannot quietly
reintroduce it: `decide(batt_w=...)` must unparse to `self.batt`.
SAFETY-24 is now named in peakguard.py, in its own section, with the number that
makes it real - 878 Wh of forced discharge on the 2026-08-20 replay - and the
statement that this must not go to a client install before that ticket lands. A
ticket nobody can find from the code is a ticket nobody reads before shipping.
RED AND GREEN
Fifteen mutations run against the shipped modules, each reverted after: the six
new wiring ones (B1, B2, B2b, B3, B3b, and deleting the SAFETY-24 pointer) and
the eight from the first round, re-run to confirm they still bite. All fifteen
turn test_peakguard.py red. Full suite green, test_price.py and TARIFF-03's
included.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
9f8b721a4d |
Merge release/1.0 (TARIFF-02) into SAFETY-07
checks / unit (pull_request) Successful in 3m9s
Conflict was the one anticipated: both cards prepend to CHANGELOG.md's Unreleased section. Both entries kept, SAFETY-07 first. Nothing else of TARIFF-02's surface (app/price.py, validate.py rule 7, config.yaml, DOCS.md) overlaps this card - config.yaml and validate.py are untouched here, so the CFG-03 check still reads a config.yaml that only TARIFF-02 has widened. Full suite green on the merge result, test_price.py included. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
303525cfc5 |
TARIFF-03: static day/night and fully-fixed tariffs, first-class
checks / unit (pull_request) Successful in 2m43s
§9.2 puts a large share of the Belgian installed base on a static profile, and
an EMS that only works under dynamic pricing is an EMS for a minority. A new
`static_profile` option describes a two-period day/night tariff - or a single
fixed price - and app/static_tariff.py turns it into the same canonical
{start, eur_per_kwh, provisional} series the fetched providers emit.
Not a sixth provider plugin, for two mechanical reasons. capabilities() is a
classmethod, so a plugin's PriceProduct is fixed when the class is written -
but §9.2 makes STATIC and FIXED two different products and which one a site is
on is a property of the operator's data; StaticProfile.product derives it from
the number of distinct prices. And the plugin framework exists to stop a
FETCHED figure being marked up twice, which a number typed as all-in cannot be.
So the profile sits where §11.4 already says it does - under the providers, as
the fallback. Configured product and feed-is-down are one generator differing
in one flag, so the degradation path cannot rot unused.
"No arbitrage" is a type. TariffPlan.arbitrage() returns a variant whose
ALLOWED arm carries the spread and the cheapest/dearest hours and whose REFUSED
arm carries a reason and nothing else - .spread_eur_kwh on a refusal raises
rather than answering 0.0, so an optimiser cannot compute a trade from one.
Four refusals, all derived: peak guard holding, no price data, plan
provisional, or the series is FLAT. The last is AC2: a fixed tariff disables
arbitrage by arithmetic, not by matching on an enum. peak_guard_active is a
required keyword argument, so §10.1's priority 2 over 3 cannot be skipped.
Time-window shifting reaches the one shiftable load that exists: main.py's
cheap-window flag falls back to the static profile, and the UI gained a Tariff
row. Cheap is STRICTLY below the seven-day mean - `<=` would call every hour of
a flat tariff cheap, and 48 h taken on a Friday is two-thirds weekend.
A profile must tile every day type exactly once, checked at startup; a gap is
refused with the range named rather than filled in. `22:00-07:00 mon-fri` does
not cover Saturday morning, and that trap is what the check catches.
validate.py rule 7's stated reason expired exactly as TARIFF-02 predicted: the
test_price.py section 12 tripwire went red naming static_tariff.py. The message
now says what is true instead, and the tripwire is re-aimed rather than removed
- consumer set pinned, expired phrase asserted gone. Rule 7 also grew a second
refusal for static_profile alongside the HA price pair, the same silent-loser
conflict and a live one.
CFG-03 is not widened: static_profile went into price.py's PRICE_OPTION_DEFAULTS
- the one in-code mirror pinned to config.yaml by a check - and the new module
carries no defaults dict of its own.
Measured on the two committed days of this house's real P1 meter. 2026-08-20
(Thursday): 15.220 kWh imported, 9.606 day / 5.614 night, EUR 4.7185 under
day/night vs EUR 4.6725 flat, shifting saves EUR 0.8069 = 9.606 kWh x the
0.0840 spread, derived twice. 2026-08-23 (Sunday): 0.728 kWh, all of it
night-priced, which is the weekend row proving itself. §17 names six Belgian
scenarios; this is the seventh, and it is two days rather than a season - the
file says so rather than implying an annual figure.
All 12 suites green. Eleven mutations of static_tariff.py were each caught by
at least one check.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
616b62d3e9 |
SAFETY-07: cap the loop before it sets the month's billed capacity peak
checks / unit (pull_request) Successful in 3m7s
TARIFF-01 measured the quarter and said the consumer would be this card. It is
one new module, app/peakguard.py, and one new claim.
THE MECHANISM. Every cycle the guard projects the open 900 s block to its
end-of-interval average - from P1 telegrams only, never from the command - and
compares it to a ceiling. Over the ceiling it files ONE arbiter claim: a lower
bound on the setpoint at P_PEAK. That single shape is both behaviours 10.1 asks
for, a hard clamp on charging and pre-emptive discharge, and it cannot cap
discharge or export, because a floor cannot. 9.1's asymmetry becomes a property
of the object instead of a rule to remember.
excess = 900 x (projected - ceiling) / seconds remaining
floor = MEASURED battery power + excess
The 900/remaining gain is 1.0 at the top of the quarter and grows, so the guard
is gentlest where its projection rests on the least evidence. The floor is sized
from delivered battery power, not the standing command: a floor built on intent
re-adds its own unmet ask every cycle and winds to the rail whenever the inverter
fails to follow, and test_peakguard.py part 1 shows the two diverging.
IT TRIPS, AND THE CAPTURES DECIDED THAT. On the healthy reference day it engages
on zero of 95 quarters. The action is level-triggered, unlatched and re-derived
every cycle, so a false engagement costs one cycle of discharge rather than a
parked battery - the cost SAFETY-18 could not bound and this one can. Replayed on
2026-08-20 the billed quarter goes from 5029.8 W, above the inverter's own 5000 W
rating, to 3485 W, under the soft limit and without saturating. Quarters under
the limit across both committed days: 189/190 -> 190/190. Two days is not thirty
and AC 3 remains TARIFF-01's open item.
BLINDNESS IS CHECKED BEFORE THE PROJECTION IS GRADED, and it is a different
action. A fresh averager projects a confident 0 W, which is under every ceiling
there is; a meter gap longer than meter_max_age_s makes the projection read LOW;
a frozen meter reading export projects 0 W at full coverage. All three become a
floor of 0 W - no importing while the billed quantity is unobservable - which is
one-directional and cannot cost pack energy. That is the backstop SAFETY-18 could
not be: its alarm arrives at 300 s of a 900 s quarter and commands nothing. The
frozen term is freeze.looks_frozen() itself, on this cycle's standing command.
THE CEILING IS peak_cap_w, RAISED ONLY BY AN OBSERVED READING. NO_RECORD and
NOT_OBSERVED both leave it at the cap, so an unreadable peak store makes the
guard stricter and never looser. The gate is the reading's STATE, not whether a
number happens to be attached: today a `peak_w is not None` test behaves
identically, and depending on that coincidence is how a future last-known-peak
field would raise the ceiling off a read that failed. headroom_w() is
deliberately not consumed - cap minus peak turns a zero peak into FULL freedom.
TWO DEFECTS FOUND BUILDING IT, both in the interaction rather than the
arithmetic, and both caught by running the thing rather than by reading it:
* A LIMIT does not out-vote another LIMIT. arbiter.resolve() applies every
limit at or above the winner's priority and takes the most restrictive, so
the peak floor (lo >= 0) and the maintenance charge-only shaping (hi <= 0)
resolved to a CONTRADICTION and 0 W - the battery parked in the exact quarter
it should shave. Fixed by suppression, not priority: main.py drops the
maintenance shaping while the guard is engaged, which is what that branch
already did for the optional peak_forecast_entity - a key empty on a default
install, so until now the suspension could not fire on the site that needed
it.
* Thresholding `excess > 0` released the claim the instant it began working,
producing seventeen engage/release cycles in one 900 s quarter and leaving
that quarter 49 W over the limit it had spent fifteen minutes holding. That
is 10.2's oscillation. The threshold is now the floor itself, which is the
same arithmetic read as a level rather than as a switch.
PeakTracker.project() no longer reads a private name with a default.
getattr(averager, "_last_net", 0.0) failed quiet AND disarming - a rename credits
0 W held, the projection reads low, the money guard does not engage.
QuarterAverager.held_net_w is a documented public property now, read without a
default, and Projection carries it. TEST-13 item 4.
NO NEW OPTION AND NO FOURTH DEFAULTS SITE. The ceiling is peak_cap_w, the
coverage threshold is meter_max_age_s, the freeze predicate is meter_freeze_s,
and the achievable discharge comes from max_w and the device rating. config.yaml
and validate.py are untouched; 14's capacity_peak_limit_kw stays declined. On
meter_source: off there are no telegrams, so the guard does not run at all and
the status page says NOT COVERED - running it there blinded it permanently and
stopped every legacy install from charging, which is what the first cut did until
test_clamp.py's export case caught it.
test_peakguard.py: eight parts, all figures derived from the shipped config.yaml
and the committed captures. Part 8 runs seven one-line defeats of the guard and
reports which check bites; six do, and the seventh is reported as NOT caught,
because max(cap, peak) makes a zero peak the strictest ceiling there is and there
is nothing left to catch.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
f4914a174a |
TARIFF-01: measure the month's billed peak, and make it survive a restart
checks / unit (pull_request) Successful in 2m38s
The 15-minute block average was already built and unwired. p1.QuarterAverager computes clock-aligned 900 s blocks, time-weighted over irregular telegram spacing, offtake-only and per-phase; P1Ingest.blocks was a 96-entry list in memory that a restart erased. So this is the persistence and the monthly reduction, not a second accumulator - a second one would be a second source of truth for the exact quantity the money depends on. BLOCKS, NOT A SLIDING WINDOW. The card says "rolling"; 9.1 bills "the highest 15-minute average offtake" and states its own worked case per QUARTER - one 4998 W quarter moving a monthly peak from 4832 to 5013 W. A trailing window reports a peak the meter never bills, and reports it HIGH: a burst straddling :15 fills the window completely while contributing to two block averages at partial weight. DELIVERED, NOT INTENDED. tariff.py only ever sees P1Sample - the meter's own reading - and never a setpoint. SAFETY-20's open question does not arise for a capacity tariff: the utility integrates the current that flowed. AN UNREADABLE STORE IS NOT A ZERO PEAK. peak() answers OBSERVED / NO_RECORD / NOT_OBSERVED with peak_w None unless observed, which is riglock.holder()'s fix applied to something that spends money. A peak read as 0 W hands SAFETY-07 maximum headroom and disarms the guard at the moment its own storage breaks. Restart mid-block resumes the accumulator through a new snapshot()/restore() pair, checkpointed every 15 s and cleared in the same breath as a block close. The held sample keeps its ORIGINAL timestamp, so an outage is integrated under the same max_hold_s rule a running process would apply. quarter_start is the primary key and a re-bank may only ever RAISE a figure. Calendar months are LOCAL: a quarter starting 22:15 UTC on 31 August bills in September. No new option (the limit is the existing peak_cap_w), so config.yaml and validate.py are untouched and CFG-03 is not widened. No second peak entity: peak_forecast_entity stays the input to maintenance_charge_floor(), because repointing that consumer changes what moves energy and belongs to SAFETY-07. AC 3 is NOT met. It asks for 30 days of replay; two days of this house's real meter exist and are committed here. test_tariff.py part 9 replays them, reports the percentage next to the sample size in days, and asserts nothing about 95 %. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
4b521b2df0 |
ci: trigger a run on the rebased head
checks / unit (pull_request) Successful in 2m33s
No content change. The gate never created a run for |
||
|
|
0942228d65 |
Merge release/1.0 (SAFETY-03) into TEST-06
checks / unit (pull_request) Canceled after 0s
Two conflicts, both predicted, both mine as the later merger. app/main.py - #12 inserted `await self.check_output_clamp()` on the line immediately above `await self.check_meter_frozen()`, so its hunk abuts my comment correction. Resolved so EACH CALL CARRIES ITS OWN BOUNDARY, because the two guards do not share one: - check_output_clamp() reads `self.clamp_last`, which is None until write_setpoint() has run, so its boundary IS the write; - check_meter_frozen() grades `self.target`, assigned further up, so its boundary is the assignment. Letting my correction generalise across both would have been worse than the vague comment it replaces, because it would read as deliberate. The AST of app/main.py is identical to merged release/1.0 (+1251 bytes, all comment). test_freeze.py - #12 independently added `frozen_notes()` keyed on the same id. `notes_of()` subsumes it: same id, plus the title fallback that keeps the id's own check independently falsifiable, plus `all_notes_of()` for claims about the whole surface. THE THREE SURFACE-WIDE ASSERTIONS, DECIDED ONE AT A TIME. Measured on the merged tree: scenario surface ids freeze frozen meter, railed command 2 frozen + clamp 1 TEL-05 converged, -14.2 W 0 - 0 moving meter, a real 8 kW load 1 clamp 0 uncovered transport, no unchanged_s 1 clamp 0 - the wiring scenario STAYS SURFACE-WIDE and now asserts exactly TWO alarms with BOTH IDS NAMED. The answer to "is this still meant to raise one alarm" is no, it raises two, and a third guard has to come back to this line. That is the one assertion in the file that accounts for the controller's entire alarm output; - the CONVERGED case stays surface-wide and stays silent: at the operating point the whole add-on should have nothing to say, that is still true, and narrowing it would give away a real property; - the other two NARROW to notes_of(). The clamp alarm there is correct and is SAFETY-03's subject: a real 8 kW load does drive the loop past the rating, and an uncovered transport does not stop it. Asserting whole-surface silence would make this file fail whenever another guard correctly does its job. Each still owns the load-bearing half - THE FREEZE DETECTOR SAID NOTHING - and the surface is PRINTED so a reader sees what else fired without this file grading it. Re-verified on the merged tree: M1 RED 4, M2 RED 5, M3 RED 3 + RED 2, N6 RED 1, N3 green (correctly), N8 RED 4, R1 RED 2, R2 RED 1. All nine suites green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
d31a12b7c6 |
TEST-06: the id-selection note said 'the only assertion'; there are two
checks / unit (pull_request) Successful in 2m32s
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2983d7c3b0 |
Merge remote-tracking branch 'origin/release/1.0' into TEST-06
checks / unit (pull_request) Canceled after 0s
|
||
|
|
611d3dbcdf |
TEST-06 review follow-ups: two notification surfaces, the real ordering boundary, the schema bounds
1. notes_of() could not tell this guard's alarm from anybody else's. It selected by SERVICE, so against #12's app/ (which adds goodwe_output_clamp) eight assertions went red, AC1's core check among them. Blanket id-keying is not the repair and was measured, not guessed: selector vs #12's app/ id renamed by service (as committed) 8 red 1 red by id alone 3 red 6 red by id or title (shipped) 3 red 1 red all_notes_of() is the whole surface; notes_of() is this guard's, recognised by the id it should carry OR the title it writes - the `or` is what keeps the one assertion whose subject IS the id able to fail on its own. The three surface-wide claims stay surface-wide, each with a comment naming which surface it is about and why the next guard's author must decide rather than narrow them. They are the three that go red against #12, which is the correct signal. 2. The ordering comment named the wrong boundary. N3 - moving the call to immediately before write_setpoint() - is green and correctly so: self.target is assigned two lines earlier, write_setpoint() clamps only a local and can skip the write entirely. So the invariant is "after `self.target = resolution.target_w`", and the detector grades pre-clamp INTENT, not the wire. Corrected in test_freeze.py and in main.py's own note above the call (comment-only; I merge second and own the conflict). N8 - moving the call above the assignment - is RED 4. 3. The schema range's own bounds are now pinned. int(60,3600) -> int(1,86400) survived green: an operator could set meter_freeze_s: 86400 and the guard is dead with nothing red. Both bounds are re-derived rather than restated. 4. find_hwsim() crashed the whole suite on a checkout one level below the root (HERE.parents[1] -> IndexError, reproduced at C:/goodwe_controller). Guarded. And part 3 now names its transport in the summary: the rig hwsim and the stub are not equivalent - the rig path failed 1 run in 3 - so a green log has to say which one backed it. Also: the "revived transport re-rails" check is labelled a PRECONDITION like its sibling; freeze_rows() records that flipping p1_enabled exercises the row's content and never its gate; and the note about the deleted assertion is corrected - it was REDUNDANT, not undecidable. The reviewer falsified it in one line (move the hass.call above `if not fired: return`, RED 9). "I could not construct a falsifier, therefore it cannot fail" was exactly the inference this file exists to distrust. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
46383c5ae5 |
Merge release/1.0 (CI-01) into SAFETY-03 so the required check can run
checks / unit (pull_request) Successful in 2m32s
Branch protection on release/1.0 now requires the context `checks / unit (pull_request)`, and CI-01's workflow arrived after this branch was cut - so no run had ever been triggered for this PR and the required context would have sat pending forever. Clean merge, no conflicts: .gitattributes, .gitea/ci/Dockerfile and .gitea/workflows/checks.yml only. No add-on source or check is touched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
4e66583a52 |
SAFETY-03 review fixes: both clamp stages always run, and two checks that could not fail
1. BEHAVIOURAL, and a regression this PR introduced. clamp_to_rating() returned early from the max_w stage, so the device bound was applied only when the rating bound had NOT fired - the bigger the overshoot, the less the guard did. At max_w 5000 against a +-4000 device, +9999 emitted +5000 W, outside the device range, while +4500 was correctly held to +4000. It undid the pre-PR guarantee "never send a value the device will reject outright" and undercut this module's own case for max_w-not-min(), which rests on that stage catching a validation that did not run. Both stages now always run; the result names both bounds when both bite (max_w+device). Asserted over a 492-point sweep, because the defect was invisible to any single-value check sitting inside one stage. 2. The hysteresis check issued range(CLEAR_CYCLES - 1) clean cycles, which at CLEAR_CYCLES = 1 issues zero, passes, and prints "0 clean cycles do NOT clear it" - green for the chatter setting the constant exists to prevent. Now: ONE clean cycle must not clear the alarm, a literal that does not move with the constant, and the de-assert count is measured by looping until it clears. 3. The re-assert check stimulated at REASSERT_S + 9, green for any value including 3600 - the hour of silence the module promises not to produce. Now stated in wall-clock terms: a loop pinned across the 900 s capacity-tariff quarter must speak at least 5 times and on no more than 20% of cycles. Pinned in both directions. Red confirmed for each: the restored early return (3 checks), CLEAR_CYCLES = 1 (1), REASSERT_S = 3600 (1) and REASSERT_S = 0 (3). Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c34b5a2922 |
TEST-06: close the three gaps that survived SAFETY-18's suite green
None of the three is a bug in the shipped code. They are gaps in what the
suite could detect, and the next person to touch freeze.py had less
protection than the passing count implied.
1. WHERE check_meter_frozen() runs in cycle(). Moving it to the top left
the whole file green. Pinned by CONSEQUENCE, not by source order, so a
refactor that keeps the semantics stays green:
- the alarm must land on the SAME cycle the command reaches the rail
(at the top it grades the previous command against this cycle's
meter and arrives a cycle late);
- the dead-poll-task composition: poll task dies, stale_input_s is
crossed, the arbiter commands 0 W, and on THAT cycle the alarm is
already clear - because the detector ran after the 0 W write.
wired() now returns a per-cycle trace, which is what makes "on which
cycle" an observation rather than a hope.
2. The NOT COVERED status row. The old check only asserted that an
uncovered transport is SILENT, which a page claiming `armed` on a guard
that cannot run also satisfies. The string is now asserted in both
directions: the uncovered row must say NOT COVERED, name the
meter_source and homewizard_local, and warn; the covered row must still
say armed, or "does not say armed" would be satisfied by deleting the
armed branch.
3. meter_freeze_s. Pinned in test_validate.py by MAINT-04's regex
technique (no PyYAML in the image), and in test_freeze.py by its
consequences: the shipped value drives the replays, must stay inside
the 900 s billing quarter, and 3600/hold_s must stay inside the shipped
deadband. A Controller built with the key ABSENT must land on the same
number, which pins main.py's fallback without touching CFG-03.
All three demonstrated red before being accepted green, and every new
check was mutated to confirm it can fail; one candidate assertion ("no new
notification while parked at 0 W") was DELETED because no mutation could
break it, and replaced by the exact notification count across a revived
transport, which can.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
9c1a23328a |
CI-01: this repository's first automated check
checks / unit (pull_request) Successful in 2m39s
Before this commit `admin/goodwe-addon` had no `.gitea/workflows/` directory at all. Eight runnable test files - `test_loop.py` alone drives the real `run_control()` for 93 s of wall clock - and not one of them had ever been run by a machine. Every merge here was a human reading a diff, and the product owner's requirement that a green CI gate a merge could not be met on a repository with no CI to be green. One job, `unit`, with no `paths:` filter, so it reports on every PR and can therefore be a REQUIRED status check: Gitea leaves a required context it never receives pending forever, which is the failure mode on the other side of this ticket. Concurrency is scoped per PR from the start rather than to a bare group name - the bare name is what let the infra repo's run 521 be superseded while still pending, so its four jobs concluded `cancelled` with `started_at` at the Unix epoch and its PR merged on no evidence at all. The tests run in `.gitea/ci/Dockerfile`: `alpine:3` plus `py3-aiohttp` and `py3-paho-mqtt` from apk, matching goodwe_controller/Dockerfile exactly, because pip would install glibc wheels of a library the shipped image gets from Alpine. The runner itself cannot host them - bare python3, no aiohttp, no pip - and mutating a shared long-lived runner with `apk add` is invisible to anyone reading this repo. Two things measured while building it and recorded in the file rather than learned again: the checkout must sit two levels below the mount root or test_freeze.py's `find_hwsim()` dies on `IndexError: 1` before its first assertion, and test_freeze's hwsim section is silently absent here because admin/goodwe is private - so its PASS is a weaker claim than it looks, and the file says so. Verified green on release/1.0 content before this workflow was written: 8 of 8 files pass, ~4 minutes. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c040aac4b8 |
SAFETY-03: alarm when a computed setpoint exceeds the rating, do not just clip it
The clamp was never the missing half. specs.md 10.3 records an unclamped integrator climbing ~130 W per 4 s past 10 kW and reporting 14 768 W pinned at the 5 kW rail; clipped silently that is a flat, legal-looking 5000 W hold and nothing says the loop asked for three times it. write_setpoint() - the one path every write takes - now clamps to the VALIDATED max_w and reports whether the raw value differed; check_output_clamp() raises OUTPUT_CLAMP as a notification, an ERROR, an event row and a red status banner. Not a trip: the clamped value is written and the loop keeps running. The rating is max_w and nothing is min()ed at runtime - CFG-01 already refuses a max_w outside the device range at startup. The device range is applied second as defence in depth; it cannot bite after a successful validation, so if it ever does it alarms too and names the bound. No new config key. Decision grew i_clamped / clamped booleans, and that is the load-bearing part: `reason` is one string that slew-limiting and the saturation freeze overwrite, so an alarm keyed on it is silent on exactly the cycles a winding loop produces. Mutating main.py back onto the string drops the 10.3 replay from 2 engagements to 0. Distinct from saturation by construction - no shared reason code, notification id, status row or counter - and checked in the negative, after first asserting the saturation freeze really did engage. Two things found by running it rather than by reading it: a row per engagement flushed the 40-row event log and evicted SAFETY-18's own METER FROZEN? row (now coalesced per episode with an exact count), and a naive clamp turns a nan into a command at the full rating because every comparison against nan is False. test_clamp.py is new: assert-based, no framework. Six author mutations reproduced red, including "clamp kept, alarm deleted". Two of the check's own hypotheses about the freeze/clamp interaction were refused by its sweep and rewritten to what it measured. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
7cde5d862a |
Merge release/1.0 into SAFETY-18 - CHANGELOG only
MAINT-04 (#10) landed on release/1.0 mid-review, so both branches had prepended a stanza. config.yaml and DOCS.md auto-merged clean; only the CHANGELOG needed a hand. Both stanzas are kept verbatim, MAINT-04's Unreleased above the new 0.5.2 - no text from either author edited. MAINT-04 is unreleased and 0.5.2 is being cut here, so a release manager may want to fold the two; that is an editorial call, not a reviewer's. Full suite green on the merged tree: arbiter, control, loop, maintenance, p1, validate, watchdog, freeze. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
ffb8ec6373 |
MAINT-04 review: pin the default divergence with a check, not a comment
validate.py's comment said "if config.yaml's value moves, move this and main.py's together" and nothing enforced it - a comment where a check belonged, in a PR that elsewhere proves it knows the difference. test_validate.py now reads main.py and maintenance.py directly and asserts the divergence EXACTLY AS IT STANDS: config.yaml/validate.py at 2000, main.py's two fallbacks and MaintConfig's dataclass default at 2500. It records the mismatch rather than demanding it be closed, so it passes today and goes red if either side moves - including when somebody closes it in main.py, at which point the check and validate.py's block are deleted together. Nothing in a file another ticket owns is touched. The consequence is asserted through the real code as well as the literals: with the key absent the validator accepts, MaintConfig builds 2500 W against a 2000 W ceiling, and the arbiter resolves it to 0 W as a contradiction - the bug rule 6 exists to catch, passing rule 6. Production-unreachable (the Supervisor always supplies every key) but fully reachable from sim/inject.py and the tests, which is where anyone debugging maintenance works. Also: a CHANGELOG section for the upgrade path, covering both the case where the Supervisor re-derives the default and the case where it persisted the old one, since which applies was not verifiable without probing the live install. And maintenance.py's timeout comment said 13.5 kWh where everything else says 13.8 (300 Ah x 51.2 V, DoD 90); SAFETY-18 does not touch that file. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
0ba3a200fe |
SAFETY-18: verify on the real rig, and record what it showed
AC3 says "verified on the rig". The previous commit drove hwsim in-process because `riglock status` reported UNKNOWN - which is the tool declining to observe, not an observation. riglock shells out to the local docker CLI; on a Windows host without DOCKER_HOST that resolves to a Docker Desktop npipe which is not running, and the result is indistinguishable from a genuinely absent rig. The rig was up the whole time. With DOCKER_HOST=ssh://homelab@192.168.2.147 it reads FREE. Re-run under sim/riglock.py against the real goodwe-sim compose project, with the shipped modules staged into goodwe-sim-plant so they poll that container's own hwsim while plantsim drives it. Both phases passed, lock released cleanly. The rig produced a result the in-process stub could not, and it strengthens the design rather than merely confirming it: in the NEGATIVE twin - +8000 W of house load, healthy meter, correctly railed command - `active_power_w` did not move at all, sitting at exactly 10130.0 W for 26 consecutive polls. The only thing keeping `unchanged_s` at 0.0 s was the kWh registers advancing. So the register terms in measurement_fingerprint() are not belt-and-braces for this detector, they ARE the negative case: fingerprinted on the power figure alone it would have raised a false alarm on a healthy meter under a real load, which is precisely how a safety guard gets switched off. Recorded in freeze.py so nobody simplifies the fingerprint without meeting that run first. No behaviour change - documentation and the harness note only. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
7aa1bd052e |
SAFETY-18: a meter frozen at a wrong-but-fresh value now raises an alarm
A meter that answers 200 OK with a stale document forever is ARRIVING on every
poll, so every freshness mechanism in the stack reads it as healthy while the
loop integrates a constant error and rails: 360/135/75 s at the live install's
max_w: 5000 for a meter frozen at 350/1000/>=3000 W. Fifteen minutes of a 5 kW
unattended import sets the month's billed capaciteitstarief peak.
The detector is a conjunction, not the bare unchanged_s threshold TEL-05
measured and rejected:
unchanged_s >= meter_freeze_s AND |command| within 5 % of max_w
Both terms already existed and were already on the status page, and they fail
for independent reasons: at the converged point the command is nowhere near the
rail, and at the rail against a real load the kWh registers move in seconds. At
the shipped 300 s the relation is structural rather than a margin - the slowest
a healthy 1 Wh register can tick and still look unchanged is 12 W, which is
inside the 15 W deadband, so the command there is parked at 0 W.
Notification only, deliberately: an HA persistent notification with a fixed
notification_id, an ERROR log line, a UI event and a red status row. No claim,
no latch, no 0 W. A false trip parks the battery; a false notification costs an
alert. Only meter_source: homewizard_local is covered - the status page says
NOT COVERED elsewhere rather than pretending the guard is armed.
DOCS.md states the capacity-tariff exposure this does NOT close: peak_cap_w caps
maintenance charging and nothing caps the loop. That cap is SAFETY-07.
test_freeze.py grades both directions and was verified by breaking what it
watches (six mutations, all red): silent over the committed 40-minute converged
capture, silent over an hour of TEL-05's low-power case where the rejected bare
threshold is shown to fire, alarming on a genuinely frozen meter driven over
real HTTP through the real HomeWizardLocalSource (the rig's own hwsim freeze
fault when reachable), silent on the same railed command against a meter that is
still moving, and asserting on the service call that leaves Controller.cycle()
rather than on the watchdog's own flag.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
878a6ce452 |
MAINT-04: refuse a maintenance charge the ceiling cannot deliver
config.yaml shipped max_w 2000 against maintenance_charge_w 2500. The cheap-window shaping files Claim.limit(hi = -maintenance_charge_w) against the supervised SAFETY limit's lo = -max_w, so lo > hi - the arbiter's clause 3, correctly resolved to 0 W and logged as a CONTRADICTION. Maintenance silently never charged in a cheap window on a default install, and the only evidence read like a bug in the arbiter rather than like the two numbers the operator set. validate_startup_config() now refuses maintenance_charge_w > max_w, the same shape as CFG-01's sign_disagree_w >= max_w. Equality is reachable (-max_w is a single valid point) and is not refused. Demonstrated by starting the add-on on the pre-fix pair: exit 78 and the refusal banner. maintenance_discharge_w was checked rather than assumed and is NOT the same case: the drain phase OWNS the actuator (Claim.set at P_MAINTENANCE), so the ceiling clamps it to +2000 W and the arbiter's explain() names the clamp every cycle. Loud, and it still moves energy - warned, not refused. The shipped maintenance rates drop to 2000 so the defaults pass the rule; max_w was deliberately not raised, because it is the supervised safety ceiling. test_validate.py now reads config.yaml itself, so a default the validator refuses cannot ship again. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e40eb0768d |
SAFETY-02: the P_PEAK assertion was pinning the test's copy of the gate
Review finding 2, and it is the same duplication `disagrees()` just removed, so
it gets the same fix rather than a follow-up card.
`following_from()` in test_watchdog.py was a TRANSCRIPTION of the gate in
main.py, carrying "keep the two in step" as an instruction - which is exactly the
arrangement that does not keep two things in step. Measured: editing the shipped
gate alone to `winner in ("loop", "peak")` left every suite green while the
watchdog went blind for the duration of every peak event. The row whose whole job
is to force whoever lands peak shaving to come and change an expectation did not
do that.
The expression is now `watchdog.loop_is_following()`, called by main.py and by
the test. One definition, two callers, same reasoning as `disagrees()`: the copy
that drifts is always the one in the harness doing the grading.
⚠️ AND EXTRACTING IT WAS NOT SUFFICIENT - the drift proof still came out green
after the extraction, which is why it was worth running rather than assuming. The
realistic P_PEAK row has peak shaving asking for MORE than the loop, so the
magnitude term rejects it whatever `winner` says and masks the term under test. A
second row with peak asking for LESS makes `winner` the only deciding term. With
that row, widening the shipped gate fails two checks; without it, none.
Also enforcing the write ordering that was documented and not asserted: swapping
the two `store.set` calls passed everything. A store that fails the second write
now proves the property the ordering exists for - a crash mid-trip leaves a
reason with no latch, never a latch with no explanation. Swapping them now turns
that check red.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
cc4e88490b |
SAFETY-02 review: a latch that a restart clears is not a latch
BLOCKER. `auto` was persisted and `sign_wd.tripped` was not, so reconstructing the Controller against the same store - which is what a container restart does - brought it back ARMED, into the same fault, unattended: tripped=False, banner back to NOT READY, and it resumed commanding -1000 then -2000 W before re-tripping 180 s later. "Restart the add-on" is the first thing an operator looking at a FAILSAFE banner and a 0 W inverter will try, and under a supervisor that restarts a crashed add-on it is a loop of three-minute wrong-direction bursts. DOCS.md's "it does not clear itself" was false across a restart. `sign_tripped` and `sign_reason` are Store keys now, beside the maintenance state and for the reason store.py's own docstring gives. Written the moment the trip happens - reason first, flag second, so a crash between the two can never persist a latch with no explanation - restored in Controller.__init__, cleared only by the operator's start. The regression is covered: reverting the restore fails seven checks in test_watchdog.py. Review follow-ups, no behaviour change: - The arming gate is tested against the REAL arbiter. It is the decision the ticket turns on and it was asserted in three comment blocks and verified by nothing - every case passed `following` in as a literal. Twelve claim configurations now derive it from resolve(), including the redirect case `winner == "loop"` alone would have got wrong and the `lo` limit that raises magnitude without flipping sign. - The MQTT `status: "failsafe"` value is tested. The check that claimed to cover it restated the line above it and never touched the payload. - The worked example described a config that does not ship: at the defaults maintenance_charge_w 2500 against max_w 2000 is an arbiter contradiction and 0 W, not a -2500 W charge. Rewritten at 1500 W. The contradiction is a real pre-existing bug - a default cheap-window maintenance charge silently never happens - filed separately and deliberately not fixed here. - Forward hazard recorded at the gate: `winner == "loop"` disarms the watchdog under any higher-priority SET, and a peak-shaving strategy at P_PEAK IS grid-following in sign, so it would blind this for every peak event. - disagrees() is public so the replay harness stops carrying its own copy of the predicate it grades. - held_s takes the clock instead of reading one. - The two limits are now each stated in both places rather than one each. - The no-false-positive argument is tied to control.py's freeze permitting the command to cross zero; under the shrink-only encoding control.py records as rejected, this would false-trip on a load step. - Measured figures corrected: 93.4 % / 4212 of 17280, per-cluster 0.3/0.9/10.5/0.0, and the near-circularity of those figures is now stated rather than leaned on. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
9aed43990b |
SAFETY-02: a loop can be fresh, tracking and inside its rating and still push the wrong way
The stale-input watchdog asks whether the meter is still talking. The saturation freeze asks whether the inverter can follow. The output clamp asks whether the number is too big. A loop can pass all three while charging the battery out of the grid, because the only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly that four times in one day, for up to 77 minutes at a stretch, reaching a commanded -14 768 W against a ±5000 W inverter. app/watchdog.py compares the emitted setpoint against the authoritative P1 figure and, when they oppose each other with both over 300 W for 180 s continuously, files a failsafe SET claim at P_SAFETY, commands 0 W and latches there until an operator starts control again. Validated against that day rather than against an argument: sim/replay_sign.py in the infra repo drives this module over the committed captures of both 2026-08-20 and the healthy 2026-08-23 and reaches 18 trips on the fault day - every one inside a window NOTES.md §4.7 accounts for - and 0 on the healthy day. The four episodes do share one signature: 0.3 / 0.9 / 10.5 / 0.0 % sign agreement inside them against 92.9 % healthy. Three decisions the ticket could not make: - It is DISARMED whenever the grid-following loop is not what is driving. Sign agreement is a property of a loop that follows the meter, and a maintenance grid charge opposes the meter by design - 2500 W of charge into a house drawing 500 W is +3000 W on the meter against a -2500 W command, for hours. The gate tests the emitted number, not the winning claim's name, because a limit claim can let the loop "win" and still replace its value. - The trip LATCHES. Commanding 0 W removes the command side of the comparison, so the disagreement always clears the moment the trip works. - sign_disagree_w at or above max_w is refused at startup. The arbiter never lets a command exceed max_w, so such a threshold leaves the watchdog incapable of firing while the status page still reports it armed. What it does not catch, said out loud: an inverter that ACTS opposite to its command moves the meter further the same way, leaving command and meter in agreement. That is the saturation freeze's job. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
aae74d7571 |
SAFETY-12 review: name the safety claim that could not fire, and fix two figures
Review fixes. A. test_loop.py takes 73 s, not the ~35 s claimed in three places. That number is the whole defence against a future developer deleting a slow test, so it was understated by 2x in exactly the place it matters. Corrected - and it is now ~95 s (measured 93 s), because this commit adds the scenario below rather than trimming windows to make an inconvenient number smaller. Both call sites carry an instruction to re-measure if the windows change. B. "242 checks" was test_p1's own count quoted as the total for all five suites. The real figure is 395 across the five, plus 14 here. And the finding this PR should have led with. stale_input_s and the `inputs missing -> 0 W` claim both live INSIDE cycle(), so pre-fix, on a meter whose value happened to repeat, that claim could not fire at all. Constant meter, SoC entity dying at t=4 s, one binary: pre-fix final target 220.0 W, reason 'loop -> 220 W' post-fix final target 0.0 W, reason 'safety -> 0 W' The old controller held 220 W through the whole input outage with its status line still reading loop -> 220 W, and layer 1 does not cover that on a `meter_source: off` install - no P1 age sensor is published, so the firmware has nothing to veto on, while the heartbeat keeps its watchdog fed. The pre-fix behaviour was not "holds a stale command safely"; it was a failsafe a repeating meter switched off. Asserted in test_loop.py, both halves. Three points of reasoning tightened, none of them wrong before: - the re-tune is unreachable by construction, not merely by the reset: the combined cycle rate is max(arrival rate, 1/floor), never the sum, and 1/15 s is strictly slower than the ~1/5 s arrival rate. That holds only while the floor exceeds the meter's update interval - and the schema minimum of 5 s is exactly the reference meter's interval. Flagged for validate.py, not fixed here. - the ~11 s lower bracket is not only a dropped poll: a 5.0 s poller against a 4.97 s meter beats, so about every 14 minutes the poller steps over an update entirely. Reaching 15 s takes a beat-skip AND a failed poll. - the "freshness is decided upstream" guarantee is transport-conditional. On `meter_source: off` the grid figure comes straight from hass.number() with no age gate. Running the full law is still right; the claim is narrower than it was stated. The 15 s default is not independently justified - it rests on the firmware's 30 s ingest veto and moves if that ever does. Said beside the constant. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
8cc9438aec |
SAFETY-12: record the six-minute observation, not just the unit check
test_loop.py proves the property in 35 s. This is the same three scenarios run for six and three real minutes each, on one binary, and it is what AC2 and AC3 were actually asked for: 1 cycle before vs 24 after on a constant meter with the command stuck at 220 W against a 350 W import, and byte-identical write sequences on both the converged and the normally-changing meter. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
96a808a057 |
HANDOVER: run every suite before deploying, and say why one is slow
The pre-deploy command listed three of the five suites; test_validate and test_p1 were never added when they arrived. Adds those and test_loop, with a note that test_loop's ~35 s is the cost of proving a wall-clock property about a loop that sleeps 1 s a tick rather than a sign something is wrong. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
88cd97cc7a |
SAFETY-12: the loop thinks on a clock, not only when the number moves
run_control() ran cycle() only when the meter value differed from the previous poll. A meter that repeats a value therefore ran no control cycles at all - while the heartbeat kept re-emitting the last command and the firmware kept putting it on the wire every 2 s. Layer 1 stayed fed and every indicator read healthy, so a command computed from an old reading went on being executed through whatever the load did next. TEL-05 measured it: 70 s at a literally constant 350.0 W, 14 arrivals, zero cycles. cycle_floor_s (default 15 s) is a deadline on the GAP between cycles, reset by every cycle whichever trigger fired - not a second scheduler. On a healthy meter it never elapses, so the cycle rate and the commanded sequence are unchanged; test_loop.py asserts that by driving the real loop twice on one binary (a huge cycle_floor_s reproduces the old behaviour) and diffing the writes. 15 s is bracketed: above the ~11 s worst gap on a merely-unlucky healthy meter (~5 s arrivals, 1 s detection, one dropped poll retried on the next tick), below meter_max_age_s and the firmware's 30 s ingest veto, and equal to stale_input_s. A floor cycle runs the full law. Freshness is already decided upstream - past meter_max_age_s the reading is None, which is a P_SAFETY 0 W claim - and the integrator advances per cycle, not per second, so bounding the gap bounds the accumulation. Not a freeze detector: nothing here decides whether a repeated reading is true. DOCS.md's "accepted deviation" passage is qualified rather than deleted - the window is now bounded at 3 x cycle_floor_s instead of open-ended, and its "nothing accumulates while it is stalled" argument is called out as having covered windup and not staleness. Same correction in control.py's comment. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
547d796c5d |
CFG-01 review: widen the rule, refuse the firmware-veto case, fix the stop footgun
Review findings, all confirmed in code before changing anything. THE RULE DID NOT AUTHORISE ITS OWN BEST REFUSAL. The stated test was "makes a safety mechanism inoperative, or makes a stated limit untrue", and a blank setpoint_entity does neither - layer 1 pinning the inverter at 0 W is the failsafe WORKING, as validate.py's own text admitted. The real justification is a second, separate category: the add-on is inert and indistinguishable from healthy. Stated as (a) and (b), with each refusal tagged, and with both halves explicitly bounded - (a) is not "any two numbers that could disagree", (b) is not "anything degraded". Left implicit, the gap is where trivia-creep comes back in. meter_max_age_s ABOVE THE FIRMWARE'S VETO IS NOW REFUSED. The schema allows int(5,300); the firmware's threshold is a compile-time `max_age_s: "30"` and it trips layer 1 at `p1_age_s >= 30`. At 120 the add-on believes a 119 s reading is fresh and keeps commanding while the board has already vetoed and is holding at 0 W - healthy meter, running controller, nothing moving. Structurally identical to the max_w case, and unlike max_w it is settable on this install, so the headline behaviour finally has a live demonstration. That firmware file's own comment says a lower bound on this "belongs in CFG-01, not here". Only ABOVE is refused: below the veto the add-on gives up first, which is fail-safe and visible on its own status page. Scoped to P1 being enabled, because meter_max_age_s governs nothing otherwise. FIRMWARE_INGEST_VETO_S cannot be imported from a compile-time YAML substitution, so it carries a note on the single direction in which it can go stale - and a warning that TEL-06 is editing `ingest_stale`, so a matching integer may stop meaning a matching rule. stop= WAS A LIVE FOOTGUN. It defaulted to None, which made a Controller that cannot stop itself the DEFAULT one. On the late-refusal path that meant: log the banner, return, and leave the process alive forever with no control loop and no exit - the exact "inert but looks healthy" failure this module exists to refuse. Now required and keyword-only, so the broken shape does not construct; test_p1.py's five call sites pass an Event. That whole path had no test and no live demo. It has one now: it drives run_control() against a device that only reports a narrower range once the loop starts, and asserts it refuses, signals, returns, and writes NOTHING - plus the converse, that an agreeing device leads to real writes. This also covers the max_w composition that cannot be reached through the Supervisor on the live install. max_w <= 0 is refused. Schema-blocked in production, but validate_startup_config() is the simulation suite's entry point too, and a non-positive max_w inverts the arbiter's supervised bounds into a contradiction that reads as a safety trip rather than a typo. Verified live 2026-08-28 (backup goodwe_controller-cfg01r2-1787940076): meter_max_age_s 120 refused with a message naming 120, 30, and THE FIRMWARE WINS; no traceback; add-on restored byte-exact and running. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
fc9bd89dca |
CFG-01: refuse to start on a configuration that cannot be honoured
main.py used to read the setpoint device's own +-5000 W rating, notice a
configured max_w above it, log one WARNING, and run anyway with
write_setpoint() quietly clamping. The operator's stated ceiling was never
the real ceiling and the only evidence had scrolled off the log. specs
§1.5 is explicit that such a config is refused at startup, not survived at
runtime.
validate_startup_config() runs in amain() before the broker, the web
server or any task exists, so a refusal cannot leave half a controller
running behind a UI. It refuses exactly three things, all sharing one
property - continuing makes a safety mechanism inoperative or makes a
stated limit untrue:
1. max_w outside the setpoint device's own rating.
2. No setpoint_entity: every write is a no-op, the device rating is
never read, and the ESP32 heartbeat that holds off the layer-1
failsafe never happens. It ran, looked healthy, and moved nothing.
3. A meter_source that can never produce a reading. These were already
caught, but they only DISABLED ingestion, which leaves grid None
forever: permanent inputs-missing, 0 W, and a status page
indistinguishable from a healthy meter nobody has fed yet.
Those last predicates move into p1.validate_meter_options(), which
build_source() also calls - one definition, two callers, not two
competing validators. ha_dsmr with half its entities and mqtt_p1 with a
blank topic gained the check the other two transports already had.
Deliberately not refused, because untidy is not unsafe: integrator_max_w
above max_w (the arbiter still bounds the wire to +-max_w, so the cost is
unwind latency - warned), a missing soc/batt entity (fail-safe and
already a red NOT READY banner), a setpoint entity that has not appeared
on the Core API yet (ESPHome is routinely late; re-checked in
run_control() once the real rating arrives), and a thin meter_poll_s
margin.
A refusal is legible as one: a banner saying in words that this is
configuration and nothing is broken, numbered problems, no traceback, and
exit 78 (EX_CONFIG).
Verified on the live add-on 2026-08-28, not by reading the code: a blank
setpoint_entity and a meter_poll_s equal to meter_max_age_s each stopped
the add-on with the banner and no stack trace.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
0422127cab |
HANDOVER said 0.2.0; the running add-on is 0.4.0
Two versions stale. 0.3.0 shipped SAFETY-04 and TEL-01, 0.4.0 shipped TEL-04 and TEL-05 and changed the meter transport to homewizard_local - so a reader taking this line at face value would look for a meter path that is no longer how this system reads the grid. Found in the 2026-08-27 backlog audit. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
80ebb96e7d |
Two comments asserted an entity id that has never existed
mqtt.py said the P1 age entity "must be exactly sensor.p1_sample_age_s, because SAFETY-01's firmware watchdog subscribes to that literal id", and main.py:340 repeated it. Both are wrong, and wrong in the direction that disarms a safety layer. On HA 2026.8 object_id in a discovery payload does not determine entity_id. HA composes it from the device name plus the entity name, so this one is sensor.goodwe_p1_sample_age. That is what the firmware subscribes to, that is what exists on the live system (verified 2026-08-26), and the firmware's own comment records that sensor.p1_sample_age_s never existed on any HA. The hazard is not the stale name itself, it is that two shipped artefacts disagreed about a safety-critical id while sounding certain. A reader who trusted these comments would have "corrected" the firmware to a name that resolves to nothing - and the failure is silent, because has_state() simply stays false forever and the ingest guard never arms. The firmware calls that out as the shape that FAILS SILENTLY AND LOOKS CORRECT. The comment now says what actually determines the id, and states plainly that renaming the device or the entity's friendly name changes the composed id and disarms the guard. It also cross-references TEL-06, since the guard reads this sensor's value rather than its arrival and so cannot fire for a dead publisher. Found in a backlog audit, as the substance behind PKG-02's premise: the real coupling between firmware and add-on is names, not versions. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
c70239cac2 |
0.4.0: the meter transports that fit this house
TEL-04 and TEL-05 merged without a version bump, so Home Assistant would not have offered the update - the same trap DEPLOY-01 caught at 0.2.1, recurring because merging a feature does not touch the version. ha_signed reads one signed entity. homewizard_local polls the meter's own API, where every HTTP response is a genuine arrival - the property the firmware watchdog needs, and the one HA cannot provide for a repeated reading. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
08f17f65dd |
TEL-05: read the meter, not Home Assistant's opinion of the meter
sensor.p1_sample_age_s measured time since the value CHANGED, not since the meter REPORTED. Home Assistant fires no state_changed for a repeated reading and exposes no arrival signal at all - proven on the rig three ways and confirmed against the live house, where ten repeated meter values left last_reported frozen every time. Real captured data in sim/scenarios/ has inter-change gaps of 42.2 s and 97.0 s, and the firmware watchdog thresholds that age at 30 s, so it would have commanded 0 W on a perfectly healthy meter. meter_source: homewizard_local polls GET /api/v1/data. Every HTTP response is a genuine arrival. Same pipeline as ha_signed - only the arrival mechanism changed. The decisive evidence is the STEADY case, not the frozen one: hwsim served a literally constant 350.0 W for 70 s - the exact state where the HA path recorded samples: 0 across 45 s - and this transport took 14 arrivals with the age never exceeding the poll cadence. Reproduced independently by the reviewer against the real hwsim, and again by the tester at 14/14. 179 -> 242 checks. Twelve mutants from the reviewer and six from the developer, every one reddening a NAMED check rather than aborting the suite. WHAT THIS DOES NOT DO. The ticket asked for two things that cannot both be true: that the age reset on every HTTP response including an unchanged value, AND that a frozen meter show a climbing age. A frozen meter still answers 200 OK - it IS arriving - so no arrival detector can do both. That acceptance criterion was wrong and was written by the PM; the developer refused it rather than quietly building half of it. Freeze detection is delivered separately as unchanged_s on the energy registers, which the local API exposes and HA never did: 70.2 s frozen against 10.0 s steady. Deliberately unthresholded, because at the converged -10 W this controller aims for, a 1 Wh register needs about six minutes to move while the power figure legitimately repeats - any threshold would rebuild the false-trip cycle at the target operating point. It is surfaced on the status line so a human can read it, which is what makes leaving it unthresholded defensible rather than a dodge. So the flash covers meter SILENCE, not meter DISHONESTY. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
4d41b0a79e |
TEL-05 review follow-ups: show unchanged_s, name a timeout, keep the poll task alive
Four follow-ups on the reviewed and approved TEL-05 work. Additive; no shipped behaviour changes except the two failure paths below. 1. unchanged_s had no operator surface. DOCS.md told a reader "the transport tracks it as unchanged_s" and there was nowhere to look: main.py built the transport, scheduled run(), and never read the object again. The status page now shows it on the healthy P1 line. Still NOT thresholded and NOT folded into the age - that refusal was reviewed and upheld, because at the converged -10 W this controller aims for a 1 Wh register needs ~6 minutes to move, so any limit false-trips at the target operating point. The whole argument for leaving it to a human requires the human being able to see it. 2. The "equivalent mutant" note on the content_type guard was wrong, and the comment is downgraded to say so. web.Response(text=...) defaults to text/plain, so the fake meter CAN serve valid JSON under the wrong mimetype. Test added; shipped behaviour was already correct. 3. A timed-out poll logged an empty reason: str(asyncio.TimeoutError()) is "", so the status page read "last error:" and then nothing, on a hung meter, at the moment the battery had just gone to 0 W. Falls back to the class name. Note str(err), not `err or ...` - an exception object is always truthy. 4. submit() sat outside the try in poll_once() and run() had no except, so a raise would kill the poll task permanently and SILENTLY - safe (the age climbs, the controller commands 0 W) but indistinguishable from a dead meter. Both wrapped; poll_s is already the retry cadence, so no backoff. Also a comment at the parse_homewizard range(phases) slice: a 3-phase meter configured as 1-phase understates the capacity-tariff figure. Filed separately, not fixed here. 242 checks in test_p1.py (236 before, 6 new). test_control 55, test_arbiter 18, test_maintenance 21, all untouched and green. Each new check proved non-vacuous: six mutations, six named reds, no suite aborts, sources restored byte-identical. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
98109a9b91 |
TEL-05: read the meter, not Home Assistant's opinion of the meter
A fourth meter_source, `homewizard_local`, polling a HomeWizard P1's own local API (GET /api/v1/data) instead of watching an HA entity. The point is the age sensor. sensor.p1_sample_age_s is FW-01's watchdog input, and on every transport we had it measured "time since the value CHANGED", not "time since the meter REPORTED". Home Assistant offers nothing better: a repeated reading emits no state_changed, advances last_reported on neither serialiser, and state_reported cannot be subscribed to at all. Measured twice - 70 s of a frozen meter on the ENV-01 rig, and ten repeated readings against the live house. Our own capture of this house's meter goes 42.2 s and 97.0 s between changes, both past the default meter_max_age_s of 30, so the age sensor would have commanded 0 W on a perfectly healthy meter. Here every HTTP response is an arrival. The meter answered, now, with its current reading; whether the number moved is not consulted. Five identical readings are five arrivals. Reuses TEL-01's pipeline rather than restructuring it: same split_signed sign convention as ha_signed, same make_sample, same ingest stamping, meter_max_age_s, clock-recomputed age, plausibility bounds and the §20 unsigned-decode rejection. A failed or timed-out poll submits nothing, so it is a missing reading - never 0 W - and does not reset the age. meter_poll_s (default 5 s, the meter's own rate) is checked against meter_max_age_s once at startup, like the ha_signed entity ids. ⚠️ An arrival stamp cannot see a FROZEN meter, and no arrival detector can - one answering 200 OK with a stale number is arriving. The local API does expose what HA never had (the total_power_*_kwh registers stop advancing) and the transport tracks it as `unchanged_s`, but it is deliberately not folded into the age and not thresholded: this controller regulates grid toward ~0 W, and at a converged -10 W the export register needs six minutes to move by its 1 Wh resolution while the power figure legitimately repeats. Thresholding that would rebuild the false-trip limit cycle at the exact operating point we aim for. test_p1.py 179 -> 236 checks. Still defaults to off. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
ad9c5772a4 |
TEL-04: a meter source for the meter this house actually has
TEL-01 shipped ha_dsmr and mqtt_p1. Neither fits the installed meter - a HomeWizard P1 publishing one signed figure, where ha_dsmr requires two unsigned registers and refuses negatives. So sensor.p1_sample_age_s could not be produced here at all. ha_signed is a subclass of HaDsmrSource overriding only _wanted() and build(), so ingest timestamping, staleness, the clock-recomputed age, plausibility bounds and unavailable-is-never-zero are inherited by construction rather than copied. A reviewer traced every inherited member and confirmed nothing in the base assumes two entities. 122 -> 179 checks. Sign convention asserted against real captures in sim/scenarios/: -5710 W at 13:46 local under full sun, +775 W at midnight, verified to the timestamp by two people independently. WHAT THIS DOES NOT DO, documented in DOCS.md, the docstring and the CHANGELOG rather than discovered later: the age it publishes measures time since the VALUE CHANGED, not since the meter reported. Home Assistant exposes no arrival signal for a repeated reading - proven on the rig against a frozen meter (no state_changed, last_reported advancing on neither serialiser, state_reported rejected outright) and confirmed independently against the live house, where ten repeated values all left last_reported frozen. So this entity must NOT yet be thresholded by the firmware watchdog. ha_dsmr has the same blind spot and escapes only statistically, because a DSMR telegram moves several entities. The fix is to read the meter's own API, where every response is an arrival. That is TEL-05, and it is FW-01's real gate. Two equivalent mutants are known and recorded: the per-phase split, documented at the site, and the incomplete-phase-set guard, which is cosmetic - both paths return False, one via an extra log line. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
1b343da8e3 |
DOCS: say plainly that ha_dsmr and mqtt_p1 have never seen real hardware
No meter in this installation uses either transport. Both were written to specs.md 5.2's assumption that a Belgian P1 exposes two unsigned registers, which the meter actually fitted here does not - it is the HomeWizard P1 that ha_signed reads. Their only coverage is test_p1.py and an end-to-end test against a fake Home Assistant. Deliberately not called "experimental". That word says the design is unfinished, which is not the defect and is vaguer than the truth; these are complete and reviewed, they have simply never had a real telegram through them. The failure this note is guarding against is a future session debugging a meter problem, treating those two paths as proven, and looking elsewhere. Placed where the mode is chosen rather than in a footnote, because the choice is the decision it should inform. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
e663e10245 |
TEL-04 review: unshadow the helper, validate config at startup, and record
what the rig proved about the age sensor
Review findings 1, 3, 5 and 6. Finding 2 is deliberately untouched - it is
its own ticket.
3. `built` was rebound at test_p1.py:816 by `built = build_source(...)`,
silently disarming the build() wrapper for anything appended below it.
Renamed to `sel`. Reproduced the reviewer's failure before fixing:
appending a check that calls built() after that line gives
`TypeError: 'HaSignedSource' object is not callable` and aborts at 163 of
180; with the rename the same probe reaches 180 and passes.
5. DOCS.md now states the "length must equal meter_phases" constraint that
config.yaml already carried, plus what leaving the list empty actually
costs: on the surveyed reading the phases carry 2769 W of import while the
connection nets 187 W, so the tariff quantity is understated ~15x.
6. build_source now checks the ha_signed wiring once at startup instead of
once per telegram: a blank p1_net_entity, or a phase list whose length
disagrees with meter_phases, logs an error and disables ingestion. Both
otherwise fail in the single way indistinguishable from a healthy source
nobody has fed yet - no samples, a climbing age, the watchdog holding the
battery at 0 W, and nothing in the log.
1. THE AGE SENSOR. Measured on the ENV-01 rig against the real HomeWizard
integration, meter frozen via hwsim's `?fault=freeze` seam (cleared in a
finally:, rig verified restored):
- websocket state_changed for the meter over 70 s : 0
- last_reported advanced (REST serialiser) : no
- last_reported advanced (websocket serialiser) : no
- subscribe_events(state_reported) : rejected,
"Event filter is required for event state_reported"
So Home Assistant exposes NO arrival signal for a repeated reading, and
the proposed fix - stamp from last_reported via subscribe_entities - is
not available. subscribe_entities listens only to EVENT_STATE_CHANGED, and
as_compressed_state carries no last_reported at all.
The age is therefore "time since the value changed", which on ha_dsmr is
mostly harmless (a telegram moves several entities) and on ha_signed is
not: one entity means a healthy meter under a flat load is
indistinguishable from a dead one. Recorded loudly in DOCS.md, in the
HaSignedSource docstring and in the CHANGELOG, with the measured 42.2 s
and 97.0 s gaps from our own capture.
meter_max_age_s is deliberately NOT widened. The two conditions produce an
identical signal, so a larger number does not separate them - it only
chooses which of the two errors you get, and it would disarm the watchdog
for a genuinely dead meter as well. The honest fix is an arrival stamp the
meter itself provides.
test_p1.py: 174 -> 179 checks, all green. Other three suites unchanged.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
632be44f6c |
TEL-04: make a missing build() guard fail legibly instead of aborting
Review point from the non-vacuity run. Deleting build()'s "is the net entity cached at all" guard makes build() raise KeyError rather than return False. That still failed the suite, but by aborting it with a traceback at whichever check ran first - a red that costs the next person ten minutes deciding whether the suite is broken or the code is. New `built()` helper in test_p1.py wraps build() and turns an escaping exception into a returned value, so the comparison against True/False fails by name. Applied only to the ha_signed section; TEL-01's own checks are untouched. Mutation 4 before: 0 named checks red, aborted at check 123 of 174. Mutation 4 after: 2 named checks red - "nothing cached yet builds nothing" and "an unavailable entity does not build a sample" - all 174 reached. Still 174 checks, all green, and the other nine mutations are unchanged. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
8b51a51e20 |
TEL-04: a third meter_source for a single signed entity
TEL-01 shipped ha_dsmr and mqtt_p1, and neither can read the meter that is
actually fitted here. The house has a HomeWizard P1 exposing ONE signed
entity, sensor.p1_meter_active_power (+ import, - export); ha_dsmr wants two
unsigned registers and refuses a negative one outright, which is every
exporting telegram. So sensor.p1_sample_age_s could not be produced at this
site, and FW-01's watchdog needs it - measured, not theoretical: the house P1
went 51.1 s and 36.2 s without a state change overnight, both past
meter_max_age_s 30, so without the age sensor the watchdog would false-trip
the battery to 0 W.
Adds meter_source: ha_signed, reading p1_net_entity (and optionally
p1_phase_net_entities in L1..L3 order for the capacity-tariff peak). The
derivation is split_signed(), sitting next to make_sample's subtraction for
the same reason it does - the moment a user is asked to write two template
sensors that split a signed value, the sign convention is back in unreviewed
YAML underneath a safety input, which is exactly what TEL-01 removed.
The transport is a subclass of HaDsmrSource overriding only _wanted() and
build(), so every rule TEL-01 established is inherited rather than
re-implemented: ingest timestamping, meter_max_age_s, the clock-recomputed
sensor.p1_sample_age_s republished ~1 Hz, the plausibility ceiling, the
"prime the cache from get_states but never build a sample out of it" rule,
"a reconnect emits nothing", and unavailable/unknown treated as a MISSING
reading and never as 0 W.
Defaults to off. An existing install is unaffected until it opts in.
test_p1.py: 122 -> 174 checks. Includes an end-to-end run of the new
transport against a fake Home Assistant websocket, and the sign convention
asserted against real captured readings from
sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json (-5710 W at
13:46 local under full sun is export; +775 W at midnight is import).
Non-vacuity: ten mutations of the new rules, each applied alone and reverted
byte-identical. Nine turn the suite red. The tenth - splitting the per-phase
signed values rather than passing them through - is an equivalent mutant,
because make_sample subtracts the two lists again and does not sign-check
per-phase figures. That is recorded in a ponytail: comment at the site rather
than left for the next reviewer to rediscover.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
|
||
|
|
c24bc0a011 |
Pin LF, because the deployment target is a Linux container
core.autocrlf=true gave the checkout CRLF .py and .yaml. run.sh happened to be LF, which is the only reason a plain copy would not have produced a "bad interpreter" failure on the add-on's entrypoint. 0.3.0 was deployed by extracting from git with autocrlf forced off and verified byte-identical to the blobs before copying. This makes that the default rather than something the deployer has to remember. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
80402c978f |
DEPLOY-01: 0.3.0, so the update is installable at all
release/1.0 carried SAFETY-04 and TEL-01 but still declared version 0.2.1 - identical to what is installed and running on the house. Home Assistant keys add-on updates off the version string, so the update would never have been offered. Two files. No code, no option defaults. What reaches the house at these defaults is SAFETY-04's control law alone, and it carries a 4,928-case equivalence proof against the previous law at integrator_max_w: 0. TEL-01 is inert until meter_source is turned on. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
6c980e87b0 |
DEPLOY-01: bump version to 0.3.0, changelog for SAFETY-04 and TEL-01
Fixes the version collision noticed while planning DEPLOY-01: release/1.0 still carried version 0.2.1, identical to what is already running on the live system, so Home Assistant would not have offered the update at all. - config.yaml: version 0.2.1 -> 0.3.0 (minor: TEL-01 adds a feature, SAFETY-04 changes the control law's internals) - CHANGELOG.md: 0.3.0 entry for SAFETY-04 and TEL-01, in the existing voice No code under app/ touched, no option defaults changed. Verified: meter_source: off, integrator_max_w: 0, target_grid_w: -10 all unchanged. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
505a847d85 |
TEL-01: P1 ingestion, with the derivation and the sample age the EMS owns
Evidence at sign-off: 122 checks in test_p1.py, 14 mutations all red with the tree restored byte-identical, and an end-to-end run of the HA transport against a fake Home Assistant websocket server with a real auth handshake. Age semantics verified live rather than from fixtures - a real 2.2 s sleep with no telegram arriving, age climbing 2.2004 s. The deliverable that matters beyond this ticket is sensor.p1_sample_age_s: recomputed against a monotonic clock and republished ~1 Hz rather than stamped per telegram, so a meter frozen at a constant value - which pushes no state change and therefore emits nothing - still shows an age that climbs. SAFETY-01's firmware subscribes to it and trips on has_state() && state >= max_age_s. Two blockers on the way, both of which would have shipped. With meter_source off - the default, chosen for zero regression - the age was published anyway and climbed without bound, which would have crossed max_age_s within half a minute and pinned every installed inverter at 0 W. And a reconnect emitted a synthetic sample that reset the age, hiding an outage from the watchdog that exists to catch it, contradicting the module's own docstring while a test asserted the violation. Not verifiable without hardware, and not claimed: real DSMR entity ids and units, whether a real P1 MQTT bridge matches the documented strict schema, the 0.35 s debounce against real telegram timing, and MQTT reconnect against a real broker. Known limits, both documented and filed as SAFETY-12: mqtt_p1 cannot detect a frozen bridge that keeps republishing, and a value-frozen meter stops the control loop cycling at all - the latter pre-existing and affecting the legacy meter_entity path today. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
f498d5fa54 |
SAFETY-04: bound the integrator independently of the output
Evidence at sign-off: 55 checks in test_control.py (24 on release/1.0), independently reproduced. 108,031 failsafe-release combinations swept across both grid directions, 2,500 randomised carried-i_w trajectories at 200 ticks, 300 repeated-meter-value stall scenarios - zero anomalies. The historical runaway regression uses the real 10.3 numbers and goes red when the protection is removed. Two rejections on the way. The first cut deadlocked the loop at small |i_w| and let the accumulator run 50% past the rail, which ADDED windup this codebase never had - the accumulator used to be the post-clamp command, so it could not exceed max_w by construction. The second deadlocked at i_w == 0.0 in the export direction, found by sweeping the boundary after three reviewers had each covered the same half of it. The finding worth keeping: deleting the integrator freeze outright failed 0 of 55 checks, because the integrator bound truncated to exactly the value the fixture asserted. A neighbouring mechanism was standing in for the one under test. The same pattern turned up again in the output clamp. test_control.py now carries the audit table and its invariant - every mechanism in compute() must be noticed by at least two checks when deleted. Deliberately not met as literally written: the detector counts cycles, not the 10 s the AC specifies. compute() is clockless and cycle() runs only on a changed meter reading, so there is no wall-clock window at all. Documented in the code and in DOCS. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |
||
|
|
4bd659c499 |
TEL-01 review fixes: stop the age sensor tripping installs that have no meter
T-1, and it was a fleet-wide trip to zero. publish() emitted p1_age unconditionally, and published_age_s counts from P1Ingest.__init__ when no sample has ever arrived. With meter_source defaulting to off, every existing install would have published sensor.p1_sample_age_s climbing without bound; the ESP32 does `has_state() && state >= max_age_s` and forces the layer-1 failsafe, so each of them would have pinned its inverter at 0 W within 30 s. Exactly the opposite of the zero-regression the off default was for. The key is now omitted from the payload AND from MQTT discovery when P1 is off, so the entity does not exist at all - which is the status quo, and what has_state() is testing for. The predicate is one function, is_enabled(), because the grid reading, the task start and the discovery announcement have to agree or this comes back. T-2, connect no longer manufactures a sample. get_states returns whatever HA currently holds, which after a Core restart is a RestoreEntity value of unknown age; stamping it with ingest_ts=now reset the age and reported a fresh meter that could have been dead for an hour. run()'s own docstring already said a reconnect must emit nothing - the code disagreed with it, and a test asserted the violation. The cache is still primed, so the first real state_changed builds a complete sample; the age just stays honest until one arrives. T-3, gaps are no longer filled with the last held value. The averager held a sample forward across any interval, so a meter dying at 5 kW and returning ten minutes later credited 5 kW x 600 s to the capacity-tariff accumulator - a fabricated peak on a permanent record. The hold is capped at max_age_s: past that the stretch is walked so block boundaries still land correctly, but nothing accumulates and elapsed does not grow, which is what finally makes the comment about a gap dragging the billed average down true. Same threshold for control and billing: a reading too old to steer by is too old to bill by. T-4, the out-of-order/duplicate guard is covered. It was untested, and the reason is worth recording: the obvious assertion passes without the guard, because the negative interval is separately refused by the covered > 0 test. What the guard prevents is the timestamp REWIND, which only shows up one sample later as a re-integrated window. The test now goes one sample later. T-6, DOCS was wrong about latency. meter_max_age_s and stale_input_s stack, so meter death to 0 W is 45 s and not 30. Documented as a table with both clocks. Also documented the T-5 asymmetry rather than papering over it: the age measures arrival, not change, so a stuck MQTT bridge republishing its last telegram still looks fresh. Correct on ha_dsmr, not detectable on mqtt_p1 without a change-detector. Written up as a known limit. Writing the T-1 test caught a second defect in the test itself: it recorded only MQTT topics, and object_id lives in the payload, so "the age sensor is not announced" had been passing for the wrong reason. test_p1.py: 99 -> 122 checks. 14 mutations run, all 14 red, files restored byte-identical - including one per fix above. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
f47f1f0129 |
TEL-01: P1 ingestion, with the derivation and the age the EMS owns
A Belgian P1 meter publishes two UNSIGNED registers, not one signed figure. Until now the add-on asked the installer to bridge that gap with a template sensor, which put the sign convention of the whole control loop in a text box. This moves it into the EMS: net = import - export, derived once, in one place, with a test that fails if anyone inverts it. Two transports behind one contract, chosen by `meter_source`: the HA WebSocket subscribing to the DSMR integration's entities, and MQTT on a configurable topic. Everything downstream reads P1Ingest, so switching is a config edit. `meter_source: off` is the default and keeps the existing meter_entity path, so no installed system changes until it opts in. The other half is the timestamp. Every accepted sample is stamped at ingest with a monotonic clock, `meter_max_age_s` is applied to it, and the age is published as sensor.p1_sample_age_s for the ESP32's stale-input watchdog. That entity is recomputed against the clock every second rather than only when a telegram lands, because HA pushes state only on change: a meter frozen at a constant reading emits nothing and looks, to anything watching the value, exactly like a meter that has died. The age tells them apart. Deliberately absent: any fallback to an inverter-side power figure. The inverter's own AC power correlates 0.998 with battery power and 0.09 with the real meter, so failing over to it means regulating against your own output. A gap stays a gap - a reconnect emits no synthetic sample, and a rejected telegram never resolves to 0 W or refreshes the timestamp. Quarter-hour averages are time-weighted over clock-aligned blocks rather than a mean of samples, so a cadence change cannot bias the capacity-tariff figure, and only offtake is accumulated so a quarter of pure export averages to 0 kW. Per-phase import is kept separately: on an unbalanced three-phase load the phase sum and the connection net are different numbers, and only one of them is billed. test_p1.py: 99 checks, runnable with a bare interpreter and no meter. Includes an end-to-end run of the HA transport against a fake Home Assistant websocket. Stacked on SAFETY-04; nothing here touches control.py. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
680461c9bf |
SAFETY-04: record the coverage audit as a comment, with its invariant
The audit found a dead mechanism twice, both times a clamp standing in for the mechanism under test, so the technique has to survive this ticket. Not as a script: the only cheap way to automate it is to key on source lines, that goes stale silently, and a green audit that has quietly stopped testing anything is this ticket's own failure mode one level up. Automating it properly would mean decomposing compute() to make its statements separately addressable, which is a refactor of the most safety-critical function in the repo for the benefit of test tooling. So it goes in as a comment block next to the checks it describes, carrying the commit it was measured at, the thirteen figures, and the invariant with the teeth in it: every mechanism must be noticed by at least two checks when it is deleted, and adding a mechanism means re-running the audit. A comment cannot go stale-green, because it never claims to be running. Also recorded: fixtures must sit clear of every rail they are not testing, which is the rule both misses violated; and the `python -B` / clear-pycache discipline, with the reason (CPython invalidates on source mtime-in-seconds plus size, so a same-second same-size rewrite reuses stale bytecode) and the reason it casts no doubt on the figures (the error is one-directional, so every number is a lower bound). Figures are the lead's independent reproduction. I re-measured the one that differed: the detector is 11 for `saturated_now = False` and 10 for the weaker `frozen = False` form, so the table names the form. test_control.py stays at 55 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
389d9ecd6d |
SAFETY-04: stop the clamps standing in for the mechanisms under test
AC 3 - "integration freezes while saturated" - had no non-vacuous test. Deleting the integrator freeze outright failed 0 of 55 checks: the two checks that name it used a fixture at max_w 2000 with the integrator bound following it, so a wound value was truncated back to exactly 2000 and the assertion passed on the clamp instead. Fixture lifted to max_w 5000, clear of every rail. Deleting the freeze now fails 2. Then swept the whole function for the same pattern, one mechanism at a time: delete it, count which checks notice. It found a second instance - the OUTPUT clamp. `clamped to max_w` and `clamped to -max_w` were both satisfied by the integrator bound truncating first, so removing the output clamp failed only the reason-string check. Those two fixtures now set integrator_max_w above max_w so the mechanism they name is the binding one; the output clamp goes from 1 failure to 3. Every mechanism in compute() is now caught by a check that names it: freeze 2, integrator clamp 6, bound-follows-max_w 4, output clamp 3, slew 4, output freeze 2, deadband 5, quantise 2, detector 10, duration 2, counter reset 6, grid bias 3, None-seeding 6. No mechanism at zero. Method note: the audit disables bytecode caching. Rewriting control.py inside one second leaves a stale app/__pycache__ entry and silently under-reports - it under-reported one mutation as 2 failures where the true figure is 6. test_control.py stays at 55 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
53d301b920 |
SAFETY-04: exactly zero is its own case in the freeze tie-break
`min(moved, i_w) if i_w > 0 else max(moved, i_w)` files i_w == 0.0 under rising-only, so the first push toward charging from exactly zero was blocked permanently - the S-1 deadlock again, mirrored in sign. main.py resets i_w to exactly 0.0 on every stop and every reseed, so it is a normal state. Zero is now handled explicitly and both directions are allowed: nothing is wound, so "may not wind further" has no referent, and a first step from zero is bounded by the gain, the output clamp and the slew limit like any other. Measured before the fix, at i_w == 0.0 and frozen: 12 800 of 25 920 ticks held the integrator and 8 304 of those changed the emitted command, worst case abandoning a 2 kW charge into a 4 kW export. Note this is NOT the same as the reported symptom: at prev_w == 0 the command holds at 0 W either way, because the output freeze forbids starting a charge while saturated, and that rule is release/1.0's and unchanged. There is now a test asserting it deliberately. Tests. The durable part is a property rather than more points: over 13 041 frozen states the integrator may be held ONLY by a correction pushing it further from zero on the side it already sits, and any other hold fails. Both signs at exactly 0.0. Mirrors added everywhere the suite tested one direction of two - freeze wind/unwind while charging, i_w=-100, the export-direction runaway, the negative clamp and slew. DOCS: the cycles-vs-seconds deviation is now written down as a deviation - the "> 10 s" criterion is not met as literally written, a cycle is one CHANGED meter reading, and there is no guaranteed wall-clock window. test_control.py: 43 -> 55 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
7123aa00a4 |
SAFETY-04: revive the clamp reason, and compare reasons in the sweep
`want = i_w` after the integrator bound, so at the default limit == max_w the output clamp can never fire and `reason == "clamped"` had become unreachable. Observability only today - nothing gates on the string - but SAFETY-03 exists to alarm on exactly that engagement, so its hook was dead before it was built. The integrator bound now reports "i-clamped", and that is the signal SAFETY-03 must watch: it is the one that fires on a default install. "clamped" stays reachable for a configuration that lets the integrator run above the rail, where both fire and the output clamp - which describes the value actually emitted - is the one reported. Two names because the two events want different alarms: the loop winding, versus a command that came out over the rating. The real fix is the second half. The equivalence sweep compared (target_w, sat_count), which is how a dead reason survived 3024 cases. It now compares (target_w, sat_count, frozen, reason) and it catches this defect: dropping the emit turns it red. Deliberate rename aliased explicitly, so any OTHER reason divergence still fails. Result of adding reason to the tuple: 105 of 3024 cases differ, and every one of them is the i-clamped/clamped rename. Zero value divergences, `frozen` included. Nothing else surfaced. test_control.py: 41 -> 43 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
e46175559b |
SAFETY-04 review fixes: the freeze deadlocked, the bound was too loose
S-1. The frozen branch admitted a correction only if it shrank |i_w|. That is unsatisfiable for BOTH signs of error whenever |correction| > 2*|i_w|, i.e. whenever the integrator is near zero, so the loop stopped moving and the freeze could never clear - it clears when the inverter tracks, and not tracking is what saturation means. Measured: 0 W held into a 2 kW import indefinitely, where release/1.0 recovers on the next cycle. Re-encoded as the same asymmetric rule the output freeze has always used: may not wind further in the direction it is already pushing, may fall, cross zero or reverse. Same interpretation, an encoding that cannot deadlock. S-2. integrator_max_w defaulted to 1.5x max_w, which ADDED windup: in release/1.0 the accumulator was the post-clamp command and could never pass the rail. Default is now "follow max_w" (config 0 = unset). Measured on the 4000 W load-drop sim, first cycle after the drop: 1000 W at the new default, 1800 W at 3000. DOCS row inverted - the useful direction is below max_w, and the 14 768 W anecdote is a vendor controller, not evidence about this code. S-3. The claim that i_w=None preserved release/1.0 exactly was false, because the S-1 gate ran regardless of seeding. It is true again, and now asserted rather than asserted-about: 3024-case exhaustive comparison against a transcription of the old law, over both freeze states, both signs and either side of the deadband. Added the carried-i_w convergence/overshoot sim that the shipped configuration was missing. S-4. Cycles are distinct meter values, not seconds: cycle() runs only when the meter reading changes, so the window has no wall-clock bound. Comment and DOCS corrected; the stall is detection latency, not a windup hazard, because the same condition stalls the whole loop. test_control.py: 33 -> 41 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
37bac79ad8 |
SAFETY-04: clamp the integrator, not only the output
The loop was in velocity form: the accumulator WAS the commanded power, so "clamp the integrator" and "clamp the output" were the same line of code and could not be set apart. This makes the accumulator an explicit carried value (`i_w`), bounds it with its own `integrator_max_w`, and keeps the output clamp where it was. Killing either mechanism now still leaves the other holding - which is the point of the ticket, and what the new regression test asserts. Freeze semantics: while saturated the integrator may unwind but not wind further. A strict freeze would strand the command at whatever it reached, because the condition that releases it is the inverter tracking again, and not tracking is exactly what saturation means. The integrator is re-seeded from the arbiter's actual output whenever the loop did not get what it asked for, so entering any failsafe (all of which resolve to 0 W) zeroes it, and the first cycle after release does not dump the stale period as power. test_control.py: 24 -> 33 checks, all passing. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa |
||
|
|
5184a2cfc2 |
Rest the meter just below zero, not at zero
The deadband is a one-way ratchet: any resting point inside it holds indefinitely. Import and export are separate registers on the meter, so a loop resting at +14 W bills 0.34 kWh/day while behaving perfectly. target_grid_w (default -10 W) moves that residue onto the export register. Worst billed rest point drops from 15 W to under 5 W. Behaviour is unchanged at target_grid_w: 0. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> |