The independent review of PR #40 found AC 6 met at three of the eight claim construction sites while the check claimed to cover the class - this repository's named failure mode, a check observing something other than what it claimed, reproduced inside the check written to prevent it. WHAT WAS WRONG. Part 10g's only call-site check was a real two-inverter cycle. That cycle is auto, P1-healthy, no maintenance procedure, no tripped sign watchdog, the guard idle and arbitrage off, so it reaches `device`, `supervised` and `loop` and nothing else - three of the eight direct appends in `Controller.cycle()`. Its own check text nevertheless read "the line a mis-typed `actuator_of(...)` at a call site goes red on", and the PR body's mutation table presented it as covering the class. The reviewer proved the gap on the shipped tree: `actuator_of("maintenance")` -> `actuator_of("peak")` at the maintenance-shaping append left test_arbiter.py, test_peakguard.py and test_arbitrage.py ALL GREEN, while at a roster of two it built a site loop of -1500 W against the guard's site `lo` of 1500 W and the now-misrouted charge-only `hi = 0` - `lo > hi`, arbiter clause 3, 0 W IN THE BILLED QUARTER, SAFETY-25 §0a's fatal case from a one-word typo. The same mutation at the `failsafe` append survived too. The runtime detector does fire - `scope_violations()` names it - but it only logs; nothing graded it. THE FIX, over machinery already present. Part 10f's AST scan already reads each `claims.append(...)` in `Controller.cycle()`. All eight direct appends expose their actuator statically as `actuator=self.actuator_of('<literal>')`, so 10g now requires that literal to EQUAL the source the claim is filed under, read as SOURCE TEXT rather than evaluated - `actuator_of("peak")` at the maintenance append is the same VALUE at the shipped roster of one and a different string here. That pins all eight routing sites, on the line the typo is written, in every configuration and at every roster, exactly the way 10f pins the source set. Two further lines keep the scan from going vacuous: every direct append must be readable in that shape (a computed or hand-written actuator fails there), and the ten appends must still account for 10f's eight sources. The two INDIRECT appends carry no `actuator=` at the call site to mis-type. `peak_claim` and `arb_claim` are routed where their claim is built, and are pinned there - `peakguard.claim()` by the SWEEP_SITE sweep over every load x elapsed x battery x SoC x floor combination, `arbitrage.claim()` by test_arbitrage.py. 10g now says so at the line, and says which three of the eight its dynamic cycle actually sees, rather than rounding up. MEASURED, NOT ARGUED. Each of the eight direct appends mutated in turn to a wrong actuator - device->loop, supervised->peak, failsafe->safety, safety(stopped)->device, safety(inputs missing)->maintenance, maintenance(SET)->loop, maintenance(shaping)->peak, loop->supervised - each on a purged tree via tools/mutation_run.sh over all 17 files. All eight RED, every one of them on the new line. TWO SURVIVING MUTATIONS OF THE SAME CLASS, ALSO CLOSED. * `resolve()` did not have to honour the roster it was given: `if units is None:` -> `if True:` left the whole suite green. Ignoring the argument makes a unit that filed nothing this cycle cease to exist - a site of two reads as a site of one and stage 3 passes the whole grid target through to the inverter that spoke, which is ARCH-01's fault with its own evidence removed. test_arbiter.py part 7 now grades it on the one case that separates the two, a SILENT unit. Mutation RED in test_arbiter.py and test_peakguard.py. * main.py's N>=2 refusal was unreachable and ungraded: `if not resolution.allocated:` -> `if False:` left the whole suite green, so the right instinct was one refactor away from being deleted as dead code. The guard is KEPT - the alternative default is the ARCH-01 fault - and new part 10h grades it on the two-inverter cycle that already existed: the 0 W, the `failsafe` winner, the log line naming the roster size, and the write that follows. Mutation RED. AND THE WORDING CORRECTED. main.py does not "refuse to write" on `allocated=False`. It SUBSTITUTES a 0 W failsafe and then calls `write_setpoint(0.0)` like any other cycle. 0 W is the correct fail-toward-inaction direction and the log text is accurate about what it refuses - to BROADCAST the site target - but "refuses to write" overstates the code. Said as what it does, in the CHANGELOG, at the branch in main.py, and in 10h's own check text. `resolve()`'s docstring now says the roster argument has to be HONOURED, which is not the same as existing. 17/17 green on a purged tree. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.