DEV-02: correct the operator instruction the latch rename made wrong
checks / unit (pull_request) Successful in 4m13s
checks / unit (pull_request) Successful in 4m13s
HANDOVER.md told an operator to "delete `sign_tripped` from /data/state.json" to clear a sign-disagreement trip by hand. After this card that key is a FOSSIL: the live latch is `unit/<inverter>/sign_tripped`, and the flat one is left in the file only so a rollback finds its latch and is never read again. Following the old instruction would delete a key that clears nothing, on the one path an operator reaches while staring at a FAILSAFE banner - so the instruction would look like it had failed. DOCS.md's §SAFETY-02 section named the file but not the key; it now names both, and says why there is one per inverter. No code change; the suite is unaffected and green. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
co-authored by
Claude Opus 5
parent
e941bf7f62
commit
d48c6b971d
+11
-1
@@ -83,7 +83,17 @@ rejected.
|
||||
|
||||
⚠️ **If you are testing the failsafe by hand, note that stopping and starting the
|
||||
add-on will not clear a trip.** That is the point of it; use the *Start / stop
|
||||
control* button twice, or delete `sign_tripped` from `/data/state.json`.
|
||||
control* button twice, or delete the trip from `/data/state.json`.
|
||||
|
||||
⚠️ **DEV-02 renamed that key and the old name is now a fossil.** There is one
|
||||
`SignWatchdog` per inverter, so the latch lives under
|
||||
`unit/<inverter>/sign_tripped` — `unit/inverter-a/sign_tripped` on a
|
||||
single-inverter site. The pre-DEV-02 flat `sign_tripped` is still written in
|
||||
the file on purpose (so a rollback finds its latch) and is **never read again**,
|
||||
so deleting it clears nothing. An install upgrading is migrated on first start,
|
||||
and if the latch cannot be made to survive that migration the controller
|
||||
re-arms it from the old key and says so in the log rather than coming up
|
||||
disarmed.
|
||||
|
||||
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
|
||||
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
|
||||
|
||||
@@ -306,7 +306,9 @@ does. That is deliberate on both counts:
|
||||
always vanishes the instant the trip works. A watchdog that took that as proof
|
||||
the fault was over would hand the inverter straight back to the loop that was
|
||||
driving the wrong way, three minutes later, forever.
|
||||
- The trip is written to `/data/state.json` and restored on startup. Restarting
|
||||
- The trip is written to `/data/state.json` — under
|
||||
`unit/<inverter>/sign_tripped`, one key per inverter since DEV-02, so a trip
|
||||
caused by one inverter cannot latch another — and restored on startup. Restarting
|
||||
the add-on is the first thing most people try when they see a red banner, and
|
||||
a latch that a restart clears would bring the controller back **armed, into the
|
||||
same fault, unattended** — and under a Supervisor that restarts a crashed add-on
|
||||
|
||||