glenn schrooyenandClaude Opus 5 dd40c56ab4
checks / unit (pull_request) Successful in 2m43s
FCST-03: yesterday's prices, flagged as yesterday's, and unable to move anything
§8.3 fills the hours a day-ahead feed has not published yet with yesterday's
profile and flags them provisional, and forbids any irreversible action on such
a price. The whole risk of this ticket is one line - a carried point and a
published point are three fields and a bool, so `provisional=y.provisional`
copies yesterday's False onto today's guess and produces stale data presented as
current. That is SAFETY-18's frozen-but-fresh meter one layer up.

So the flag is never passed through. Carried points come from a constructor with
no provisional parameter; published points pass through BY IDENTITY, so no copy
exists that could lose one; an audit re-derives the expected flag for every
emitted point and raises rather than repairing; and the check walks the module's
own AST so the pass-through idiom cannot come back looking ordinary. A published
point may itself be provisional (eneco_eddy's imbalance print is), so the rule
for a published hour is "whatever the feed said", never False.

The fill keys on the Brussels wall clock rather than t-24h, so the 23- and
25-hour days are right; a late publication rebuilds the series, moving the
number and the flag together.

AC2 and AC3 landed on TARIFF-03's existing verdict surface rather than beside
it. Refusal 3 became "fewer than two FIRM hours" - refusing on "any point is
provisional" would have switched arbitrage off every morning on every dynamic
site - and refusal 5 is new: the spread must clear a threshold widened by the
widest active uncertainty source (max, never a product). The permitting variant
now refuses to be constructed around a provisional point at all, and the
cheap-window flag became per-hour for the same reason.

The irreversible action is a value carrying the hours it commits, derived from
maintenance.py's own DRAIN_TIMEOUT_MIN; the gate blocks a maintenance drain
whose window reaches into a carried hour, and the phase machine stays idle. It
is the price-justified entry point only - a gate that blocked on no_data would
stop the monthly cycle on every default install.

Zero new config options; TEST-14's signature scan ported to cover both Gate's
and Arbitrage's constructors, closing _Refused.reason's open hole.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:54:07 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
20 MiB
Languages
Python 98.2%
JavaScript 1.2%
CSS 0.3%
HTML 0.2%