90 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5 d57122ec74 DATA-02: a real Belgian price year, so AC4 stops being unmeetable
checks / unit (pull_request) Successful in 3m36s
OPT-04 reported AC4 - "net-positive across 12 months of replayed prices" -
as NOT MET and replayed a synthetic year, because scenarios/ held only P1
meter captures. Right call, wrong diagnosis: the criterion was being carried
beside a 30-day METER criterion as though both needed waiting. EPEX BE
day-ahead is public data, not a capture. It needed a fetch.

8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, canonical three
fields. Licence checked BEFORE committing: Energy-Charts publishes the BE
zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under
private-use-only terms, so this one is redistributable with attribution. The
fetcher refuses to write a file whose per-response license_info stops saying
so. Cross-checked against SMARD's own 4996/DE: 96 of 96 quarter-hours, max
difference 0.00 EUR/MWh.

Raw wholesale, and the file says so. all_in: false, with the markup/tax
assumption carried as numbers to APPLY rather than numbers applied -
TARIFF-02's trap in data form. Section 7B applies it in one visible place and
asserts arithmetically that its additive terms cancel out of every daily
spread, so the trade count turns on the VAT multiplier alone; the raw replay
is run too, so how much rests on the guess is reported (110 vs 88).

DST by construction: iterate in UTC, render through price.brussels().
2025-10-26 is 25 points, 2026-03-29 is 23, verified by counting per Brussels
day rather than asserting 24, and by checking October's 02:00 appears twice
at two offsets with two prices while March's never appears. Both bugs the
point-and-gap accounting caught were real: a UTC-bounded window made the
first day 22 hours, and an inclusive-end off-by-one dropped the last day
silently. A day nobody asked for is not a day with no prices.

THE RESULT, AT THE SHIPPED DEFAULT, WHATEVER IT IS. At 0.10 widened 1.5x to
0.1500: 110 round trips, +24.88 EUR net of the cycle cost. Unwidened, 173.
Nothing tuned - the threshold and the 2.5/1.5 factors are untouched.

And what the owner's decision now has under it: the four reports that a
static ~0.0840 spread does not clear 0.10 all STAND. What was missing is that
a dynamic site clears the widened requirement on 121 of 365 days, median
all-in spread 0.1130, so a median day would clear at 0.0754 - 156 trips,
+35.42 EUR. Reported, not applied.

The synthetic year stays, because the real one cannot grade section 17: not
one of 365 days has a negative DEAREST hour, so a zero there counts something
that could not happen. 7B asserts that degeneracy rather than reporting the
zero.

Size measured, not assumed: 893 KB plain but 74.6 KB as a git object against
56.5 KB gzipped. Git already compresses; 18 KB is not worth making the
provenance block - the licence claim a reviewer must check - unreadable in a
diff.

Nothing wired into the add-on; generic_dayahead is still the live path.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 11:01:42 +02:00
admin 4601682815 SAFETY-24: an energy floor under the peak guard's forced discharge (#21)
SAFETY-07 could command a discharge to hold a billed quarter down and nothing below it consulted the state of charge - the BMS was the sole energy backstop. decide() now takes soc and soc_floor, and discharge_permitted() is the one place the question is answered: public, no default arguments, and consulted only AFTER a forced discharge is actually being asked for. The denied action is a 0 W floor - one-directional, forbids charging, structurally cannot cap the discharge the loop is already doing.

Reviewed independently. The trade-off is ruled honest and was made a check rather than a footnote: on a pack deliberately sized so the floor must bind, the worst quarter goes 4338 -> 5030 W while end SoC goes 9.6 -> 20.0 % and cycles pinned at the BMS cut-out go 1227 -> 0. Reproduced on the reviewer's own replay, including the 304.2 Wh withheld against 292.8 Wh between the two floors - half a cycle at the rail apart, so the floor is doing the arithmetic it claims.

The guard's central guarantee was re-derived across 19,800 combinations of load x elapsed x battery x SoC x floor: 0 negative floors, 0 claims with hi other than +inf, 0 decisions both floor-limited and saturated, 0 arbiter resolutions lowered or contradicted. Rule 8's <= is right: at equality the EMS floor could never be the thing that stops the discharge.

Eleven author mutations plus nine reviewer ones, all red under python -B with a purged __pycache__ and real byte deltas. One survivor is an equivalent mutant and provably so: a float(soc or 100) defaulting above the call site is dead code, because a Controller with no SoC never reaches decide() at all - inputs_ok is False and cycle() stops at the safety claim first. That property is now asserted on the service call, replacing an assertion whose sentence was wider than its check.

Merged after two rebases. The second one broke a grader neither card could have seen alone: test_peakguard graded the FIRST .decide( in main.py and required exactly one, which stopped being true when OPT-04 added arbitrage.decide(). It failed loudly rather than grading the wrong call. Fixed by selecting peakguard.decide by qualified name and requiring exactly one of that, verified still red on a decoy and on the maintenance_soc_floor swap.

Follow-ups filed as SAFETY-27, not addressed here: arbitrage_soc_floor has no rule-8 twin against bms_soc_floor, and this card's own 'revisit if a third floor appears' trigger has fired.
2026-08-31 10:24:36 +02:00
glenn schrooyenandClaude Opus 5 9234016419 Merge release/1.0 (OPT-04) into SAFETY-24, and fix one grader the merge broke
checks / unit (pull_request) Successful in 3m36s
OPT-04 landed after the previous rebase. Conflicts were CHANGELOG.md and one
IMPORT LINE in validate.py; both refusal blocks and both option sets survive
untouched, and DOCS.md, main.py and config.yaml auto-merged.

⚠️ AND THE MERGE BROKE A CHECK THAT NEITHER CARD COULD HAVE SEEN ALONE.
test_peakguard.py graded "the first `.decide(` call in main.py" and asserted
there was exactly one. That was true when SAFETY-24 was written; OPT-04 added
`arbitrage.decide(...)`, so the merged tree had two and the assertion failed.
It failed loudly rather than grading the wrong call - the guard did its job -
but it cannot ship red.

Fixed by selecting the call by QUALIFIED NAME (`peakguard.decide`) instead of
by position, and requiring exactly one of THAT. Other modules may now call
their own decide(); this grader can no longer be moved by one of them. Verified
still discriminating: a decoy `peakguard.decide` added to main.py turns it red
on 7 assertions, and the `maintenance_soc_floor` swap still turns it red on 6.

Also folded in the review's wording finding. An assertion read "a CONTROLLER
whose SoC entity does not answer hands decide() None" while driving no
Controller. The wiring property is stronger than the one claimed, and is now
asserted on the SERVICE CALL: a Controller with no SoC never reaches the guard
at all, because `inputs_ok` is False and cycle() stops at the safety claim
first - so a `float(soc or 100)` defaulting line above the call site cannot
disarm the floor. The original decide()-level check is kept, reworded to say
what it actually grades.

Full suite green on the merged tree: 15 files.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 07:39:40 +02:00
admin b7272169b1 SAFETY-26: pin the negative-price boundary from below, not just from above (#23)
Closes the survivor found reviewing OPT-04: price < 0 weakened to < -0.001 left every suite green while a -0.0005 EUR/kWh sell hour discharged. Pinned as a sweep rather than a point - five magnitudes spanning >10000x down to -0.000001, the last place the canonical 6-decimal format expresses - with the well-formedness of each stimulus asserted first so section 17 is the only rung that can refuse, and the same five sign-flipped asserted to discharge so it is a boundary at exactly zero. app/ untouched.
2026-08-31 07:37:46 +02:00
glenn schrooyenandClaude Opus 5 2b8b8cb97f SAFETY-26: pin the negative-price refusal from below, not only from above
checks / unit (pull_request) Successful in 3m15s
OPT-04's reviewer weakened `if price < 0` to `if price < -0.001` and every
suite stayed green while a -0.0005 EUR/kWh sell hour discharged. The shipped
code was right the whole time; the CHECK could not tell correct from
nearly-correct. The only probe near the boundary sat at 0.0000, which catches a
`<=` and says nothing about a tolerance invented on the other side - and a
tolerance on the other side is §17's named regression walking through with the
suite passing. A dearest hour at -0.0005 is an ordinary Belgian day-ahead
print, not a fuzz value.

`app/` IS NOT TOUCHED. `if price < 0` is already correct and changing it would
be the defect; this card closes the check, not the behaviour. The 0.0000 probe
stays and is now labelled as the half that pins the boundary from above.

The new probe is a SWEEP rather than a point, because one probe at -0.0005
closes `-0.001` and nothing else - a mutation reaching for `-0.01` would be the
identical defect one decimal further out. Five prices span four orders of
magnitude down to -0.000001, the last place the canonical six-decimal format
can express; each is asserted to survive that rounding as strictly negative,
to still be the DEAREST hour, and to still clear the widened threshold, so §17
is the only rung that can refuse. The same five magnitudes with the sign
flipped all discharge, so this is a boundary at exactly zero rather than a
refusal of small numbers.

AC4, the look: every price/quantity boundary in arbitrage.py and
static_tariff.py was given the same tolerance mutation, both directions where
both exist. Two survive, both in static_tariff.py and both NAMED RATHER THAN
FIXED - they are TARIFF-03's rungs and want probes in its own file. `spread ==
0.0` loosened to `<= 0.001` flips a real 0.0005 spread from allowed to refused
at min_spread_eur_kwh=0.0, a documented supported value, and otherwise prints a
false reason about a tariff that is not flat. `len(firm) < 2` loosened to `< 1`
survives at +0 bytes - TEST-15's risky delta - and is masked only by the flat
rung, so the two mask each other and a later edit to either opens a hole
nothing reports.

Mutation verified under `python -B` with a recursive __pycache__ purge, byte
delta printed (+5 B), the mutated line asserted changed, and - per the
reviewer's addition to TEST-15 - the tree re-read from disk and asserted to be
the tree that was mutated before each run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 02:07:56 +02:00
admin 8e589fee3f OPT-04: price arbitrage, at priority 3, shipped switched off (#22)
app/arbitrage.py consumes TARIFF-02s canonical prices, TARIFF-03s Arbitrage verdict and FCST-03s firm/provisional split rather than re-implementing them. An idle decision files NO claim - a 0 W set at P_ARBITRAGE would out-rank the loop and kill self-consumption. Peak shaving is honoured twice: TARIFF-03s required peak_guard_active interlock, and P_PEAK 50 clamping P_ARBITRAGE 30 in the arbiter. The fetch lives in run_tariff_refresh(), asserted on the shipped AST to be absent from cycle() and read_inputs(). Selling into a negative-price hour is refused. arbitrage_enabled ships false.
2026-08-31 01:53:31 +02:00
glenn schrooyenandClaude Opus 5 bdd7f18a54 OPT-04: charge cheap, discharge expensive - and only when it pays
checks / unit (pull_request) Successful in 3m16s
Four cards built the price stack and nothing traded on it. app/arbitrage.py is
§10.1's priority 3, and it consumes all four rather than re-deciding anything:
whether a trade is permitted at all, on which two hours, against which widened
threshold is TariffPlan.arbitrage()'s answer, and that answer cannot be
obtained without first saying whether the peak guard is holding. §9.1's "peak
shaving outranks arbitrage" is therefore honoured structurally - there is no
path to a spread that skips the question - and again in the arbiter, where
P_PEAK (50) clamps a claim filed at P_ARBITRAGE (30).

A guard that never ran is not a guard that is clear. On meter_source off the
peak guard is never evaluated; that third state is carried as None and refuses,
because charging at the rail creates the billed quantity while nothing measures
the quarter. validate.py refuses that configuration too, along with arbitrage
armed with no price source and a SoC floor at or above the ceiling.

§17: never export into a negative price. The guard is on the hour being sold
into, not on the spread - a day priced -0.30 .. -0.05 clears any threshold and
its dearest hour is still negative. Buying in a negative hour stays allowed.

resolve_tariff() may open an HTTPS connection and the tick feeds the ESP32
heartbeat, so the fetch runs in its own task at a 30 min cadence and the tick
reads an attribute and an age bound. test_arbitrage.py section 8 asserts that
structurally on the shipped AST: a fetch put back on cycle() is red.

AC4 is NOT met and is not restated - this repository holds no price history.
Section 7 replays a synthetic year and asserts the property that does not need
real prices: every executed round trip cleared its own widened requirement, and
zero discharges landed in the 522 negative-priced hours. At the shipped 0.10
EUR/kWh threshold a realistic Belgian day/night site does not trade at all.
Reported, not tuned: that number and FCST-03's widening factors are one product
decision and it is the owner's.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 01:36:09 +02:00
glenn schrooyenandClaude Opus 5 a1376e44e4 Merge release/1.0 (FCST-03) into SAFETY-24 - CHANGELOG only
checks / unit (pull_request) Successful in 3m28s
FCST-03 landed while this was in review, so both branches had prepended an
Unreleased stanza. Only CHANGELOG.md conflicted, exactly as predicted;
app/, config.yaml, validate.py and DOCS.md all auto-merged, and this card
touches neither price_forecast.py nor static_tariff.py.

Both stanzas kept verbatim, SAFETY-24's above FCST-03's - no text from
either author edited. Full suite green on the merged tree: 14 files.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 00:43:58 +02:00
glenn schrooyenandClaude Opus 5 e709554857 SAFETY-24: an energy floor under the peak guard's forced discharge
checks / unit (pull_request) Successful in 3m29s
SAFETY-07 can command a discharge to hold a billed quarter down, and
nothing below it consulted the state of charge. On the 2026-08-20 replay
it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a
real floor and it works - but it is the pack's protection rather than the
operator's, and a month of aggressive quarters leaves the battery
repeatedly at that cut-out with no EMS-side record of why. The first
symptom is a pack never available when wanted, which is indistinguishable
from the SoC drift MAINT-01 exists to correct.

decide() now takes soc and soc_floor, both required and neither
defaulted, and discharge_permitted() is the one place the question is
answered. Above the floor nothing changes. At or below it the guard files
a 0 W floor instead of a sized one - one-directional, so charging stays
blocked and no discharge is capped - and reports floor_limited with the
reason it bound. It is not a trip: every stop in 11.2's table still
outranks the claim, and the floor is never negative, so 9.1's asymmetry
survives as a property of the object (0 negative floors over 1296 swept
combinations, SoC included).

The SoC is graded only after `wanted > 0` is established, so it is never
evaluated where it governs nothing. An unreadable SoC is floor-limited,
not a full battery - a full battery is exactly the value that would
disarm the floor, and this project shipped that defaulting once already.

Failing to shave is not silent: one notification per episode
(goodwe_peak_soc_floor), distinct from the saturation alarm because the
two ask for opposite operator actions, plus its own status row and an
action-log line.

Verified by replay. The 2026-08-20 capture is driven against a modelled
pack sized from the day's own measured appetite, so it genuinely
exhausts: without the floor it reaches the BMS cut-out and holds there
for 1227 guard cycles; with it the pack stops at 20.0 % and never touches
the BMS. The energy withheld equals the energy between the two floors to
within one cycle at the rail. The honest half is reported too - the worst
quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less
on purpose.

Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS
(TARIFF-02's pattern), imported by validate.py and main.py rather than
typed as literals and pinned to config.yaml by a check that reads the
file - so CFG-03 still tracks three places. validate.py rule 8 refuses
peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner.
maintenance_soc_floor is deliberately not reused and not renamed: it is a
drain target, not a spend limit, and the rename is recorded as a decision
to revisit if a third floor appears.

Eleven mutations of the shipped source were run against the checks; all
eleven go red and there are no survivors.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 00:29:36 +02:00
admin a30bde1ab1 FCST-03: provisional prices - yesterday flagged as yesterday, and unable to move anything (#20)
app/price_forecast.py fills unknown hours from yesterday, flagged provisional by four independent mechanisms: _carried() has no provisional parameter, published points pass through by identity, _audit() re-derives every flag and raises rather than repairs, and an AST check refuses a non-literal provisional. Gate blocks irreversible actions on provisional hours. Arbitrage refusal 3 rewritten to fewer-than-two-FIRM-hours so filling does not switch arbitrage off every morning, with the 11.4 fallback still refused by a truer route. Real-time products get a measured 2.5x wider threshold, following the declared PriceProduct.
2026-08-31 00:23:41 +02:00
glenn schrooyenandClaude Opus 5 71cd7849e4 Merge release/1.0 (SAFETY-07) into FCST-03, and close two degenerate stimuli
checks / unit (pull_request) Successful in 3m13s
CHANGELOG.md was the entire collision - SAFETY-07 lands in peakguard.py, main.py
and the arbiter, none of which this branch touches. Both entries kept.

X1. `_firm_or_die` guarding only `cheapest` survived, because the check passed
the SAME provisional point as both cheapest and dearest: a guard on either role
alone raises, so the stimulus could not tell "the buy hour is guarded" from
"both are". Now one call per role with a firm point in the other seat, plus the
positive arm so the two refusals are discriminating.

X6. `firm_points()` returning the carried hours too survived, because its two
consumers - the §11.4 refusal and cheap_now - guard provenance independently and
both keep answering correctly. The accessor is now graded directly: exactly the
published points, by identity and in order.

Both are the degeneracy rule this file states at the top, in a new dress - a
stimulus that cannot distinguish the two things it grades.

⚠️ AND THE REASON THE M9 MUTATION "SURVIVED" IN MY EARLIER REPORT: a stale
__pycache__. Reverting `self.provisional` to `here.provisional` changes neither
the file size nor, at one-second resolution, the mtime, so CPython kept the
MUTATED bytecode and a green run afterwards proved nothing about that line. Every
mutation here now clears __pycache__ first; re-run that way, M9 is caught. The
committed source was always correct - the checks were not being run against it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 00:15:32 +02:00
admin e7c95bfd8a SAFETY-07: cap the loop before it sets the month's billed capacity peak (#18)
The first thing in this system that can STOP a runaway rather than alarm on one. Each cycle it projects the open 900 s block from P1 telegrams and, over the ceiling, files one arbiter claim: a lower bound at P_PEAK, sized as excess = 900*(projected-ceiling)/remaining added to the MEASURED battery power. No writes, no I/O, no clock, no state between calls.

Replayed independently by the reviewer on a separate harness: 2026-08-20's billed quarter 5029.8 W -> 3485.3 W, both days 189/190 -> 190/190 under the 3500 W soft limit, 878 Wh modelled discharge on the failure day and 0 Wh with 0 engagements on the healthy one.

Verified as properties rather than witnesses: the lo-limit claim cannot cap discharge or export (hi is inf; 0 of 54 loop/floor pairs lowered the target; no floor in 0..5000 W reduces a full-rate discharge; decide() emitted 0 negative floors over 630 input combinations), and the 900/remaining gain is exactly 1.0 at the top of the block, growing, bounded at the end by the achievable_w clamp so it can never file lo > hi.

Round one held this PR on three wiring mutations that left all twelve suites green while a default install parked at 0 W in the billed quarter - including the suppression re-gated on the optional peak_forecast_entity, verbatim the historical defect this card's own comment described. All three are closed. The conjunction moved out of main.py into peakguard.shaping_suspended() so the check can assert on the shipped expression, and part 7 now executes the mutations against the real Controller.cycle(). The reviewer confirmed the harness cannot go vacuous: re-inlining the conjunction in main.py with behaviour-identical code turns B1 and B2 RED rather than green, because they assert the mutation takes effect.

Eight further reviewer mutations this round, all red, no survivors. One note recorded, not blocking: the parsed-syntax grade on decide(batt_w=...) is defeated by a decoy .decide() call or by overwriting self.batt before the call, and it is the behavioural checks beside it that catch both.

AC 3 remains TARIFF-01's and is NOT met - do not close the card as AC 3 met. SAFETY-24, the missing SoC backstop on the forced discharge, is named in peakguard.py with the 878 Wh figure and must land before this reaches a client install.
2026-08-30 23:56:20 +02:00
glenn schrooyenandClaude Opus 5 dd40c56ab4 FCST-03: yesterday's prices, flagged as yesterday's, and unable to move anything
checks / unit (pull_request) Successful in 2m43s
§8.3 fills the hours a day-ahead feed has not published yet with yesterday's
profile and flags them provisional, and forbids any irreversible action on such
a price. The whole risk of this ticket is one line - a carried point and a
published point are three fields and a bool, so `provisional=y.provisional`
copies yesterday's False onto today's guess and produces stale data presented as
current. That is SAFETY-18's frozen-but-fresh meter one layer up.

So the flag is never passed through. Carried points come from a constructor with
no provisional parameter; published points pass through BY IDENTITY, so no copy
exists that could lose one; an audit re-derives the expected flag for every
emitted point and raises rather than repairing; and the check walks the module's
own AST so the pass-through idiom cannot come back looking ordinary. A published
point may itself be provisional (eneco_eddy's imbalance print is), so the rule
for a published hour is "whatever the feed said", never False.

The fill keys on the Brussels wall clock rather than t-24h, so the 23- and
25-hour days are right; a late publication rebuilds the series, moving the
number and the flag together.

AC2 and AC3 landed on TARIFF-03's existing verdict surface rather than beside
it. Refusal 3 became "fewer than two FIRM hours" - refusing on "any point is
provisional" would have switched arbitrage off every morning on every dynamic
site - and refusal 5 is new: the spread must clear a threshold widened by the
widest active uncertainty source (max, never a product). The permitting variant
now refuses to be constructed around a provisional point at all, and the
cheap-window flag became per-hour for the same reason.

The irreversible action is a value carrying the hours it commits, derived from
maintenance.py's own DRAIN_TIMEOUT_MIN; the gate blocks a maintenance drain
whose window reaches into a carried hour, and the phase machine stays idle. It
is the price-justified entry point only - a gate that blocked on no_data would
stop the monthly cycle on every default install.

Zero new config options; TEST-14's signature scan ported to cover both Gate's
and Arbitrage's constructors, closing _Refused.reason's open hole.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:54:07 +02:00
glenn schrooyenandClaude Opus 5 c2ed509565 Merge release/1.0 (TARIFF-03) into SAFETY-07
checks / unit (pull_request) Successful in 3m12s
The anticipated conflict again, and only it: both cards prepend to CHANGELOG.md's
Unreleased section. Both entries kept, SAFETY-07 first. app/main.py and DOCS.md
auto-merged, so the overlap claim on #18 still holds - config.yaml and
validate.py remain untouched by this card even after TARIFF-02 and TARIFF-03
widened both.

Full suite green on the merge result, test_price.py and test_static_tariff.py
included.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:43:35 +02:00
glenn schrooyenandClaude Opus 5 2d570d84ce SAFETY-07 review: defend the three wiring mutations that survived
The reviewer's finding was correct and the shape of it matters: everything the
first cut graded was in peakguard.py, and grading the module is not the same as
grading the guard. Three one-line changes to main.py's CALL SITE left all twelve
suites green while a default install parked at 0 W in the quarter that sets the
month's bill.

B2 was the serious one. My own comment described that defect - "that entity is
optional and empty on a default install, so until now the suspension could not
fire on the site that needed it" - and nothing could regress it. A comment that
documents a fix nobody can test is the same shape as a corrected comment nobody
tests, which this project has already been caught by once.

WHAT CHANGED

The suppression conjunction moved out of main.py and into
peakguard.shaping_suspended(), for the reason watchdog.loop_is_following() and
freeze.looks_frozen() live where they do: the check that grades a safety
predicate must assert on THE SHIPPED EXPRESSION, not on a transcription that can
drift apart from it in silence. Its docstring carries both terms and why neither
is sufficient alone. main.py's call site now says READ THAT FUNCTION FIRST, and
records that a reviewer mutated it back to its historical broken form with every
suite staying green.

test_peakguard.py part 7 gains a section that EXECUTES the three mutations
rather than describing them. Each one is put in place on the shipped module and
the REAL Controller.cycle() is driven with it, on the dangerous fixture: a
default install (no peak_forecast_entity, so peak_fc is None and peak_at_risk is
False forever) with maintenance in its CHARGE phase, so a P_MAINT_SHAPE `hi <= 0`
limit is live, and the guard genuinely engaged on the measurement. That the
mutations are monkeypatched onto the shipped module is itself load-bearing: if
main.py inlined either expression again the patch would do nothing and these
checks would pass vacuously.

    SHIPPED   suspended=True    loop -> 1498 W, limited by peak    +1497.8 W
    B1        suspended=False   CONTRADICTION between limits           0.0 W
    B2        suspended=False   CONTRADICTION between limits           0.0 W
    B2b (forecast term dropped instead) - caught by its own check

B3 is graded three ways, because the single-cycle form is only INFLATED and the
failure is what happens on the next cycle:

  * the value main.py actually hands decide() is recorded off the real call, with
    the measured battery at 0 W and the command standing at +3000 W;
  * the one-cycle difference is asserted to be exactly the standing command - the
    whole defect in one line, watts that were asked for and never arrived counted
    as if they had;
  * both forms are then run forward against the REAL controller's own projection
    with an inverter that never follows:

        intent-sized floor    4482 5000 5000 5000 ...  SATURATED at cycle 2
        delivered-power floor 1482 1482 1482 1482 ...  stationary

  * and the call site is graded on parsed syntax, so a rename cannot quietly
    reintroduce it: `decide(batt_w=...)` must unparse to `self.batt`.

SAFETY-24 is now named in peakguard.py, in its own section, with the number that
makes it real - 878 Wh of forced discharge on the 2026-08-20 replay - and the
statement that this must not go to a client install before that ticket lands. A
ticket nobody can find from the code is a ticket nobody reads before shipping.

RED AND GREEN

Fifteen mutations run against the shipped modules, each reverted after: the six
new wiring ones (B1, B2, B2b, B3, B3b, and deleting the SAFETY-24 pointer) and
the eight from the first round, re-run to confirm they still bite. All fifteen
turn test_peakguard.py red. Full suite green, test_price.py and TARIFF-03's
included.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:40:39 +02:00
admin cf5094c608 TARIFF-03: the static day/night profile as a first-class product and the 11.4 fallback (#19)
app/static_tariff.py: StaticProfile derives STATIC vs FIXED from its own prices, one generator serves both the configured product and the degradation fallback differing only in the provisional flag. TariffPlan.arbitrage() is a refusal type behind a required keyword-only peak_guard_active, and a flat tariff is refused by arithmetic rather than by matching PriceProduct.FIXED. main.py touched only in read_inputs() else-branch, one field, one status row - nothing in cycle(), the arbiter or the peak path; an empty profile is bit-for-bit the old behaviour. Rule 7 tripwire re-aimed rather than silenced.
2026-08-30 23:24:53 +02:00
glenn schrooyenandClaude Opus 5 9f8b721a4d Merge release/1.0 (TARIFF-02) into SAFETY-07
checks / unit (pull_request) Successful in 3m9s
Conflict was the one anticipated: both cards prepend to CHANGELOG.md's
Unreleased section. Both entries kept, SAFETY-07 first. Nothing else of
TARIFF-02's surface (app/price.py, validate.py rule 7, config.yaml, DOCS.md)
overlaps this card - config.yaml and validate.py are untouched here, so the
CFG-03 check still reads a config.yaml that only TARIFF-02 has widened.

Full suite green on the merge result, test_price.py included.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:13:29 +02:00
glenn schrooyenandClaude Opus 5 303525cfc5 TARIFF-03: static day/night and fully-fixed tariffs, first-class
checks / unit (pull_request) Successful in 2m43s
§9.2 puts a large share of the Belgian installed base on a static profile, and
an EMS that only works under dynamic pricing is an EMS for a minority. A new
`static_profile` option describes a two-period day/night tariff - or a single
fixed price - and app/static_tariff.py turns it into the same canonical
{start, eur_per_kwh, provisional} series the fetched providers emit.

Not a sixth provider plugin, for two mechanical reasons. capabilities() is a
classmethod, so a plugin's PriceProduct is fixed when the class is written -
but §9.2 makes STATIC and FIXED two different products and which one a site is
on is a property of the operator's data; StaticProfile.product derives it from
the number of distinct prices. And the plugin framework exists to stop a
FETCHED figure being marked up twice, which a number typed as all-in cannot be.
So the profile sits where §11.4 already says it does - under the providers, as
the fallback. Configured product and feed-is-down are one generator differing
in one flag, so the degradation path cannot rot unused.

"No arbitrage" is a type. TariffPlan.arbitrage() returns a variant whose
ALLOWED arm carries the spread and the cheapest/dearest hours and whose REFUSED
arm carries a reason and nothing else - .spread_eur_kwh on a refusal raises
rather than answering 0.0, so an optimiser cannot compute a trade from one.
Four refusals, all derived: peak guard holding, no price data, plan
provisional, or the series is FLAT. The last is AC2: a fixed tariff disables
arbitrage by arithmetic, not by matching on an enum. peak_guard_active is a
required keyword argument, so §10.1's priority 2 over 3 cannot be skipped.

Time-window shifting reaches the one shiftable load that exists: main.py's
cheap-window flag falls back to the static profile, and the UI gained a Tariff
row. Cheap is STRICTLY below the seven-day mean - `<=` would call every hour of
a flat tariff cheap, and 48 h taken on a Friday is two-thirds weekend.

A profile must tile every day type exactly once, checked at startup; a gap is
refused with the range named rather than filled in. `22:00-07:00 mon-fri` does
not cover Saturday morning, and that trap is what the check catches.

validate.py rule 7's stated reason expired exactly as TARIFF-02 predicted: the
test_price.py section 12 tripwire went red naming static_tariff.py. The message
now says what is true instead, and the tripwire is re-aimed rather than removed
- consumer set pinned, expired phrase asserted gone. Rule 7 also grew a second
refusal for static_profile alongside the HA price pair, the same silent-loser
conflict and a live one.

CFG-03 is not widened: static_profile went into price.py's PRICE_OPTION_DEFAULTS
- the one in-code mirror pinned to config.yaml by a check - and the new module
carries no defaults dict of its own.

Measured on the two committed days of this house's real P1 meter. 2026-08-20
(Thursday): 15.220 kWh imported, 9.606 day / 5.614 night, EUR 4.7185 under
day/night vs EUR 4.6725 flat, shifting saves EUR 0.8069 = 9.606 kWh x the
0.0840 spread, derived twice. 2026-08-23 (Sunday): 0.728 kWh, all of it
night-priced, which is the weekend row proving itself. §17 names six Belgian
scenarios; this is the seventh, and it is two days rather than a season - the
file says so rather than implying an annual figure.

All 12 suites green. Eleven mutations of static_tariff.py were each caught by
at least one check.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:07:53 +02:00
glenn schrooyenandClaude Opus 5 616b62d3e9 SAFETY-07: cap the loop before it sets the month's billed capacity peak
checks / unit (pull_request) Successful in 3m7s
TARIFF-01 measured the quarter and said the consumer would be this card. It is
one new module, app/peakguard.py, and one new claim.

THE MECHANISM. Every cycle the guard projects the open 900 s block to its
end-of-interval average - from P1 telegrams only, never from the command - and
compares it to a ceiling. Over the ceiling it files ONE arbiter claim: a lower
bound on the setpoint at P_PEAK. That single shape is both behaviours 10.1 asks
for, a hard clamp on charging and pre-emptive discharge, and it cannot cap
discharge or export, because a floor cannot. 9.1's asymmetry becomes a property
of the object instead of a rule to remember.

    excess = 900 x (projected - ceiling) / seconds remaining
    floor  = MEASURED battery power + excess

The 900/remaining gain is 1.0 at the top of the quarter and grows, so the guard
is gentlest where its projection rests on the least evidence. The floor is sized
from delivered battery power, not the standing command: a floor built on intent
re-adds its own unmet ask every cycle and winds to the rail whenever the inverter
fails to follow, and test_peakguard.py part 1 shows the two diverging.

IT TRIPS, AND THE CAPTURES DECIDED THAT. On the healthy reference day it engages
on zero of 95 quarters. The action is level-triggered, unlatched and re-derived
every cycle, so a false engagement costs one cycle of discharge rather than a
parked battery - the cost SAFETY-18 could not bound and this one can. Replayed on
2026-08-20 the billed quarter goes from 5029.8 W, above the inverter's own 5000 W
rating, to 3485 W, under the soft limit and without saturating. Quarters under
the limit across both committed days: 189/190 -> 190/190. Two days is not thirty
and AC 3 remains TARIFF-01's open item.

BLINDNESS IS CHECKED BEFORE THE PROJECTION IS GRADED, and it is a different
action. A fresh averager projects a confident 0 W, which is under every ceiling
there is; a meter gap longer than meter_max_age_s makes the projection read LOW;
a frozen meter reading export projects 0 W at full coverage. All three become a
floor of 0 W - no importing while the billed quantity is unobservable - which is
one-directional and cannot cost pack energy. That is the backstop SAFETY-18 could
not be: its alarm arrives at 300 s of a 900 s quarter and commands nothing. The
frozen term is freeze.looks_frozen() itself, on this cycle's standing command.

THE CEILING IS peak_cap_w, RAISED ONLY BY AN OBSERVED READING. NO_RECORD and
NOT_OBSERVED both leave it at the cap, so an unreadable peak store makes the
guard stricter and never looser. The gate is the reading's STATE, not whether a
number happens to be attached: today a `peak_w is not None` test behaves
identically, and depending on that coincidence is how a future last-known-peak
field would raise the ceiling off a read that failed. headroom_w() is
deliberately not consumed - cap minus peak turns a zero peak into FULL freedom.

TWO DEFECTS FOUND BUILDING IT, both in the interaction rather than the
arithmetic, and both caught by running the thing rather than by reading it:

  * A LIMIT does not out-vote another LIMIT. arbiter.resolve() applies every
    limit at or above the winner's priority and takes the most restrictive, so
    the peak floor (lo >= 0) and the maintenance charge-only shaping (hi <= 0)
    resolved to a CONTRADICTION and 0 W - the battery parked in the exact quarter
    it should shave. Fixed by suppression, not priority: main.py drops the
    maintenance shaping while the guard is engaged, which is what that branch
    already did for the optional peak_forecast_entity - a key empty on a default
    install, so until now the suspension could not fire on the site that needed
    it.
  * Thresholding `excess > 0` released the claim the instant it began working,
    producing seventeen engage/release cycles in one 900 s quarter and leaving
    that quarter 49 W over the limit it had spent fifteen minutes holding. That
    is 10.2's oscillation. The threshold is now the floor itself, which is the
    same arithmetic read as a level rather than as a switch.

PeakTracker.project() no longer reads a private name with a default.
getattr(averager, "_last_net", 0.0) failed quiet AND disarming - a rename credits
0 W held, the projection reads low, the money guard does not engage.
QuarterAverager.held_net_w is a documented public property now, read without a
default, and Projection carries it. TEST-13 item 4.

NO NEW OPTION AND NO FOURTH DEFAULTS SITE. The ceiling is peak_cap_w, the
coverage threshold is meter_max_age_s, the freeze predicate is meter_freeze_s,
and the achievable discharge comes from max_w and the device rating. config.yaml
and validate.py are untouched; 14's capacity_peak_limit_kw stays declined. On
meter_source: off there are no telegrams, so the guard does not run at all and
the status page says NOT COVERED - running it there blinded it permanently and
stopped every legacy install from charging, which is what the first cut did until
test_clamp.py's export case caught it.

test_peakguard.py: eight parts, all figures derived from the shipped config.yaml
and the committed captures. Part 8 runs seven one-line defeats of the guard and
reports which check bites; six do, and the seventh is reported as NOT caught,
because max(cap, peak) makes a zero peak the strictest ceiling there is and there
is nothing left to catch.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 23:05:05 +02:00
admin 91ea676af4 TARIFF-02: price provider plugins + the canonical all-in price format (#16)
Five providers behind a registry, canonical all-in {start, eur_per_kwh, provisional}. Plugins return RawPoints and declare capabilities().sources; assemble() adds the complement once. register() refuses at import any plugin whose class code mentions a framework key, PRICE_OPTION_DEFAULTS, price_option or _o - closing the three routes review used to double-count. PriceRead.series/no_data as an absence type; all-zero is a series, no_data forbids arbitrage. Additive only: main.py untouched, zero deletions.
2026-08-30 22:35:49 +02:00
adminandClaude Opus 5 862f0fa574 Merge release/1.0 (TARIFF-01) into TARIFF-02
checks / unit (pull_request) Successful in 2m39s
TARIFF-01 (#17) landed on release/1.0 first, so this branch was two
commits behind and Gitea reported the PR unmergeable. Integrating rather
than rebasing: the two reviewed commits stay addressable, and the branch
is protected against force-push anyway.

ONE CONFLICT, AND IT IS THE BORING HALF OF THE ONE REVIEW PREDICTED.
Review of #16 expected collisions in four places - the tail of
`options:`, the tail of `schema:`, the rule list inside
validate_startup_config(), and the tail of validate.py. None of them
happened: TARIFF-01 touched neither config.yaml nor validate.py. It
added app/tariff.py, test_tariff.py, two P1 scenario captures, and edits
to main.py and p1.py, none of which this branch goes near.

The only conflict was CHANGELOG.md, where both branches prepended a
block under the same `## Unreleased` heading. Both blocks kept, TARIFF-02
above TARIFF-01 since it lands second. Nothing was dropped or reworded on
either side, and the resolution adds no line of its own beyond the blank
one between them.

Checked rather than assumed after the merge:
  - all ELEVEN test files pass, including TARIFF-01's own test_tariff.py
    (which this branch had never run) and the 93 s test_loop.py;
  - the 24-mutation battery still has 0 survivors;
  - no semantic overlap in config: TARIFF-01's peak tracker reads the
    peak_cap_w / peak_forecast_entity options that already existed, so
    the price options added here neither shadow nor duplicate anything.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 19:42:16 +02:00
adminandClaude Opus 5 e102cde841 TARIFF-02 review: close the three other doors to the markup, and stop overclaiming
checks / unit (pull_request) Successful in 2m34s
Review of PR #16 wrote a double-counting plugin four ways. PluginOptions
blocked one. The one that decided it touched nothing but
PRICE_OPTION_DEFAULTS - a public dict in the module every plugin must
already import for register() - so "the number is not in scope" was
simply false, and an absolute guarantee a reviewer trusts is worse than
a stated limit, because they stop checking.

register() now refuses, AT IMPORT, any plugin whose own code mentions a
framework-owned name: FRAMEWORK_KEYS plus PRICE_OPTION_DEFAULTS,
price_option and _o. code_leaks() parses the class and drops every
docstring node before searching, because every plugin is REQUIRED to
name its sourced components in prose - engie_dynamic says "markup" in
its docstring and a raw text scan false-positives on the documentation
the same file mandates. A check that fires on required documentation is
a check somebody deletes. test_price.py asserts that a raw scan really
would have false-positived, so the strip is proven load-bearing rather
than asserted.

It fails OPEN if inspect.getsource() cannot find the .py, which the
add-on image always can. Refusing to start a battery controller because
a static analysis could not run would trade a real outage for a
hypothetical accounting error - so instead the checks assert source was
found for all five shipped plugins, and a build that lost it is a red
check rather than a quietly disarmed guard.

All three reachable attacks are written out as plugins in the suite and
each must be refused at registration. The cost is measured, not
asserted: honest wholesale 0.188, every attack 0.219 - one markup high,
every hour, invisible in every log this add-on writes.

The guarantee is now stated at its true size everywhere it appears: the
framework adds the complement exactly once, GIVEN A CORRECT sources
DECLARATION. A plugin that declares {ENERGY} while its feed is all-in
still doubles while touching no framework name, and no code can catch
that - the declaration is an unverifiable claim about somebody else's
tariff. Measured in the suite (0.276) so the limit is a number rather
than a caveat. The docstring/declaration check verifies that a plugin's
two claims AGREE, not that either is true; that now says so.

The three surviving mutations:

M3 - _NoData's reason taking a default. This is the identical survivor
left open on RIG-01's _Unread.cause: the shape was borrowed from
sim/riglock.py including its blind spot, which is what borrowing a shape
does if nobody re-runs the mutations against the copy. Closed by
SIGNATURE - no constructor or handler of an outcome type may carry a
default - so the next one is red without anyone writing a new case.

M5 - the ENERGY-required guard was untested. Its consequence is that
adds becomes {ENERGY, TAXES} and the emitted price silently omits the
energy it is pricing.

M7 - deleting the TLS refusal went green AND the check named for it
still passed, because the old parser stripped a fixed len("https://")
and mangled http://api.energy-charts.info/p into the host
pi.energy-charts.info, which then failed the ALLOW-LIST. An assertion
that does not test what it names, inside a security check. Fixed on both
sides: the scheme is parsed as a scheme, so an http URL now resolves to
its real and declared host and only the TLS rule can refuse it; and the
check asserts the REASON. Fixing it surfaced M7b - the no-scheme guard
was survivable the same way - found by mutating my own fix, and closed
the same way.

Also carried forward: rule 7's refusal is correct forever but its stated
reason ("the provider decides nothing") expires the moment TARIFF-03 or
OPT-04 lands. test_price.py section 12 now greps app/ by AST for a
load_prices consumer and goes red when one appears, telling whoever
lands it to update the message in the same commit. The first draft of
that tripwire used a substring and matched the comment in validate.py
explaining the tripwire - the same false-positive class as the plugin
docstrings, hit twice in one ticket, and fixed the same way.

Documented rather than coded around: vars(read).get("points", []) and
bool(read) both still get past the absence type, and neither is worth
code - defining __bool__ would turn a line that reads like a guard into
one that IS a guard by accident, which is how .get(k, default) got here
in the first place.

Stated plainly in DOCS/CHANGELOG/PR: every fixture is synthetic, so the
five feed URLs and JSON shapes are verified against a belief about what
those suppliers publish rather than against the feeds. A wrong shape
degrades to no-price-data, not to a wrong price.

Review's own DST verification recorded: 149,040 hourly instants,
2020-2036, zero mismatches against zoneinfo. The residual is political,
not arithmetic, and the docstring now says so.

24 mutations driven through the suite, 0 survivors. Whole add-on suite
green. No deleted lines outside this ticket's own files; main.py still
untouched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 19:35:36 +02:00
admin 0dbd485b5a TARIFF-01: measure the month's billed capacity peak, and make it survive a restart (#17)
The instrument SAFETY-07 will read: the highest clock-aligned 15-minute average offtake of the calendar month, persisted in /data/tariff.db across two retention tiers, with a monthly peak that recompute_month() proves has not diverged from the 15-minute tier. Files no claim, applies no clamp, commands nothing.

AC 1 was already built and unwired - p1.QuarterAverager on the base already does clock-aligned 900 s blocks, time-weighted over irregular spacing, offtake-only, per-phase, with the max_hold_s gap rule; verified on 9aadf46 rather than taken on the PR's word, and the p1.py diff removes zero lines. So this is persistence and reduction rather than a second source of truth for the quantity the money depends on.

Block rather than rolling, and the reading is provable: a 900 s burst centred on a :15 boundary bills at 2000 W and reads 4000 W through a trailing window - exactly 2.00x, the supremum - and since the aligned windows are a subset of all trailing windows, a rolling figure can only ever read HIGH, never low. On the real captures, 1.09x and 1.05x.

Reviewed independently: the encoded EU DST rule graded against zoneinfo at minute resolution over eight transitions, all of 2026 hourly and every month boundary - 0 mismatches - and the wrong-arm fromutc() mutation that differs only inside the one-hour transition window now goes red, which is the class that escaped the first draft. All four persistence behaviours produced rather than read, including a hard os._exit with no close() losing neither a banked quarter nor the open checkpoint. The SAFETY-20 syntax grader discriminates on names; two evasions remain in its import half.

AC 3 is NOT met and the check says so: no 30-day dataset exists. The two days that do exist replay to 189/190 quarters = 99.5 % under the 3500 W soft limit, uncontrolled - the baseline SAFETY-07 must improve on - and 2026-08-20's peak reproduces independently at 5029.8 W, a billed quarter over the live install's own 5000 W rating. Do not close the card as AC 3 met; start the 30-day capture.

Four reviewer mutations survive, recorded on the PR. The one to act on: record_block() ignoring its policy argument stays green, because every block reaching the store in the check is single-phase where NET, SUM and MAX collapse - the third instance of the degeneracy trap this file already documents twice, sitting on the exact line the pending per-phase product decision will change.

No conflict with TARIFF-02 (#16) beyond CHANGELOG.md, verified from both sides.
2026-08-30 19:33:57 +02:00
glenn schrooyenandClaude Opus 5 f4914a174a TARIFF-01: measure the month's billed peak, and make it survive a restart
checks / unit (pull_request) Successful in 2m38s
The 15-minute block average was already built and unwired. p1.QuarterAverager
computes clock-aligned 900 s blocks, time-weighted over irregular telegram
spacing, offtake-only and per-phase; P1Ingest.blocks was a 96-entry list in
memory that a restart erased. So this is the persistence and the monthly
reduction, not a second accumulator - a second one would be a second source of
truth for the exact quantity the money depends on.

BLOCKS, NOT A SLIDING WINDOW. The card says "rolling"; 9.1 bills "the highest
15-minute average offtake" and states its own worked case per QUARTER - one
4998 W quarter moving a monthly peak from 4832 to 5013 W. A trailing window
reports a peak the meter never bills, and reports it HIGH: a burst straddling
:15 fills the window completely while contributing to two block averages at
partial weight.

DELIVERED, NOT INTENDED. tariff.py only ever sees P1Sample - the meter's own
reading - and never a setpoint. SAFETY-20's open question does not arise for a
capacity tariff: the utility integrates the current that flowed.

AN UNREADABLE STORE IS NOT A ZERO PEAK. peak() answers OBSERVED / NO_RECORD /
NOT_OBSERVED with peak_w None unless observed, which is riglock.holder()'s fix
applied to something that spends money. A peak read as 0 W hands SAFETY-07
maximum headroom and disarms the guard at the moment its own storage breaks.

Restart mid-block resumes the accumulator through a new snapshot()/restore()
pair, checkpointed every 15 s and cleared in the same breath as a block close.
The held sample keeps its ORIGINAL timestamp, so an outage is integrated under
the same max_hold_s rule a running process would apply. quarter_start is the
primary key and a re-bank may only ever RAISE a figure.

Calendar months are LOCAL: a quarter starting 22:15 UTC on 31 August bills in
September.

No new option (the limit is the existing peak_cap_w), so config.yaml and
validate.py are untouched and CFG-03 is not widened. No second peak entity:
peak_forecast_entity stays the input to maintenance_charge_floor(), because
repointing that consumer changes what moves energy and belongs to SAFETY-07.

AC 3 is NOT met. It asks for 30 days of replay; two days of this house's real
meter exist and are committed here. test_tariff.py part 9 replays them, reports
the percentage next to the sample size in days, and asserts nothing about 95 %.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 19:13:58 +02:00
adminandClaude Opus 5 852fc7ced6 TARIFF-02: one canonical price format, and a seam that keeps supplier names out of the optimiser
checks / unit (pull_request) Successful in 2m33s
Five provider plugins - generic_dayahead, engie_dynamic,
totalenergies_dynamic, eneco_eddy, manual_csv - all emitting exactly
{"prices": [{"start", "eur_per_kwh", "provisional"}]}, tz-aware at the
Brussels offset, EUR/kWh, all-in. Nothing consumes it yet; the seam
lands first, per the PM's ordering.

It is built in goodwe_controller/app/ rather than at specs.md 2.2's
ems/ingest/prices/, per the product owner's decision of 2026-08-30. The
behaviour 9.3 / 8.3 / 11.4 specifies is unchanged.

Three things shape the design, and each is the mechanism rather than a
comment saying to be careful:

Double-counting the markup is unreachable. A plugin does not return a
price - it returns the figure its source published and declares which of
{energy, markup, taxes} that figure already contains. assemble() adds
the complement, once, in the framework. A plugin is never handed
price_markup_eur_kwh: PluginOptions raises FrameworkOption on it, so the
line that adds the margin a second time cannot be written. Engie and
TotalEnergies publish a retail figure with their margin inside; adding
the configured 3 c/kWh on top would have made every arbitrage decision
wrong by that amount with nothing reporting it.

The product type is declared, not inferred from the plugin's name.
eneco_eddy is real-time/imbalance and gets 8.3's widened thresholds
through capabilities().product and volatility_regime(), never through a
name comparison - which is AC2. test_price.py asserts mechanically that
no plugin id appears anywhere in the framework's code, and drives a
sixth provider defined inside the test file to the right regime with
price.py untouched.

"No price data" is a type, not an empty list - the same rework
sim/riglock.py took under TEST-04. A fetch returns PriceRead.series(...)
or PriceRead.no_data(reason), and only the first carries fields. An
empty series is not constructible; no_data has no .points, no .at(), and
.get("points", []) raises rather than returning the default. A day of
free electricity and a day with no prices are different instructions -
arbitrage is pointless under one and forbidden under the other - and an
implementation returning [] cannot tell them apart. Every site-level
failure returns no_data; nothing raises into the control tick.

Also: injection stays a separate scalar (export_price_eur_kwh, AC4),
negative prices survive the boundary validator (17's regression case),
egress is allow-listed against each plugin's own declaration (16), and
no tzdata is used - the shipped Alpine image has none, so Brussels
offsets come from the EU rule and instants are carried as UTC.

validate.py grows rule 7: an unknown provider id, manual_csv with no
path, and - the HA overlap the PM told us to decide about -
price_provider set alongside price_now_entity/price_avg_entity, which is
two price sources where the HA pair silently wins. The HA sensors are
kept and still work alone; TARIFF-03 and OPT-04 are what replace them.

CFG-03 is not widened: the price defaults have ONE in-code mirror,
PRICE_OPTION_DEFAULTS, which validate.py imports rather than restating
and which test_price.py pins to config.yaml by reading the file.

test_price.py is runnable, assert-free in the house style, and every
verdict it prints is derived. It grades the markup arithmetic with
0.031/0.057 rather than the shipped 0.03/0.06, because 0.06 is exactly
twice 0.03 and a degenerate pair would make double-counting
indistinguishable from correct addition - and it asserts that
non-degeneracy as its first section. The DST checks run on the 23-hour
and 25-hour days, not on a normal day where a fixed 24-slot
implementation and a correct one agree. Thirteen mutations were driven
through it; all thirteen go red.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 19:05:12 +02:00
admin 9aadf469bc TEST-06: pin the cycle() ordering, the NOT COVERED string and the shipped meter_freeze_s (#14)
Closes the three mutations that survived SAFETY-18 suite green. Ordering pinned by consequence (N8 red above the assignment, N3 green below it); NOT COVERED asserted in both directions; shipped meter_freeze_s and its schema bounds pinned. notes_of()/all_notes_of() split so this guard and the whole notification surface are separately nameable, with the three surface-wide claims decided per scenario after SAFETY-03. app/ change is comment-only (AST-identical).
2026-08-30 18:39:07 +02:00
glenn schrooyenandClaude Opus 5 4b521b2df0 ci: trigger a run on the rebased head
checks / unit (pull_request) Successful in 2m33s
No content change. The gate never created a run for 0942228d - the newest
run stayed on d31a12b7, the pre-rebase head - so `checks / unit` had
nothing to report and sat pending. Why no run was created is CI-02 and
belongs to CI-01's owner; this commit only asks for one.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 18:11:21 +02:00
glenn schrooyenandClaude Opus 5 0942228d65 Merge release/1.0 (SAFETY-03) into TEST-06
checks / unit (pull_request) Canceled after 0s
Two conflicts, both predicted, both mine as the later merger.

app/main.py - #12 inserted `await self.check_output_clamp()` on the line
immediately above `await self.check_meter_frozen()`, so its hunk abuts my
comment correction. Resolved so EACH CALL CARRIES ITS OWN BOUNDARY,
because the two guards do not share one:

  - check_output_clamp() reads `self.clamp_last`, which is None until
    write_setpoint() has run, so its boundary IS the write;
  - check_meter_frozen() grades `self.target`, assigned further up, so
    its boundary is the assignment.

Letting my correction generalise across both would have been worse than
the vague comment it replaces, because it would read as deliberate. The
AST of app/main.py is identical to merged release/1.0 (+1251 bytes, all
comment).

test_freeze.py - #12 independently added `frozen_notes()` keyed on the
same id. `notes_of()` subsumes it: same id, plus the title fallback that
keeps the id's own check independently falsifiable, plus `all_notes_of()`
for claims about the whole surface.

THE THREE SURFACE-WIDE ASSERTIONS, DECIDED ONE AT A TIME. Measured on the
merged tree:

  scenario                              surface  ids             freeze
  frozen meter, railed command             2     frozen + clamp     1
  TEL-05 converged, -14.2 W                0     -                  0
  moving meter, a real 8 kW load           1     clamp              0
  uncovered transport, no unchanged_s      1     clamp              0

  - the wiring scenario STAYS SURFACE-WIDE and now asserts exactly TWO
    alarms with BOTH IDS NAMED. The answer to "is this still meant to
    raise one alarm" is no, it raises two, and a third guard has to come
    back to this line. That is the one assertion in the file that
    accounts for the controller's entire alarm output;
  - the CONVERGED case stays surface-wide and stays silent: at the
    operating point the whole add-on should have nothing to say, that is
    still true, and narrowing it would give away a real property;
  - the other two NARROW to notes_of(). The clamp alarm there is correct
    and is SAFETY-03's subject: a real 8 kW load does drive the loop past
    the rating, and an uncovered transport does not stop it. Asserting
    whole-surface silence would make this file fail whenever another
    guard correctly does its job. Each still owns the load-bearing half -
    THE FREEZE DETECTOR SAID NOTHING - and the surface is PRINTED so a
    reader sees what else fired without this file grading it.

Re-verified on the merged tree: M1 RED 4, M2 RED 5, M3 RED 3 + RED 2,
N6 RED 1, N3 green (correctly), N8 RED 4, R1 RED 2, R2 RED 1. All nine
suites green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 17:45:09 +02:00
admin 6aabb832fc SAFETY-03: alarm when a computed setpoint exceeds the rating, do not just clip it (#12)
The clamp already existed; the alarm did not, and specs 10.3 records a silently clipped integrator that reached 14,768 W while every dashboard read a legal 5000 W. OUTPUT_CLAMP now alarms on every engagement, with its own reason code, notification_id, status row and counter, distinct from ordinary saturation. Clamp lives in write_setpoint(), the one path every write takes; the alarm runs after it, out of the write path. Not a trip: the clamped value is written and the loop keeps running.

Reviewed over two rounds. Round one held the PR on three findings: clamp_to_rating() returned early from the max_w stage so the device bound was never applied when the first stage engaged (the bigger the overshoot, the less the guard did), and two checks that could not fail - range(CLEAR_CYCLES - 1) issued zero clean cycles at CLEAR_CYCLES=1, and REASSERT_S + 9 passed for any value including an hour of silence. All three fixed in 4e66583 and verified independently: both clamp stages now run on symmetric, asymmetric and wider-device ratings with no escapes; the 492-point sweep was shown to bite where the witness values cannot (a positive-side-only device bound gives 181 escapes with both witnesses passing, and a single-grid-point hole gives 1); and the rewritten checks pin the requirement rather than the constant - CLEAR_CYCLES red at 1 and at 51, REASSERT_S red at <=5 and at >=300.

Author's six mutations all reproduced red, including the cross-suite one where removing the event-log coalescing turns test_freeze red - this guard's log had been evicting SAFETY-18's METER FROZEN? row. Headline claim reproduced: keying the alarm on Decision.reason instead of the i_clamped/clamped booleans takes the 10.3 replay from 2 engagements to 0. AC2 verified with an independent saturation-without-clamping scenario: sat_count 10 at 21.6% of the rating, zero clamp engagements.

Two reviewer mutations survive, both recorded and neither blocking: describe() dropping the bound name (the bound field itself is pinned), and abs() on limit_w (unreachable under the int(100,5000) schema).

First merge in this repository to pass through CI-01's gate rather than around it: 46383c5 merged release/1.0 in so the required context could run at all, and checks / unit (pull_request) reports success in 2m32s.

Note for TEST-06 (#14), which rebases behind this: it conflicts in BOTH app/main.py and test_freeze.py, and its 8 red assertions are its own service-keyed notification counting - keying those four call sites on notification_id turns the whole suite green against this app/ with no change here.
2026-08-30 17:22:30 +02:00
glenn schrooyenandClaude Opus 5 d31a12b7c6 TEST-06: the id-selection note said 'the only assertion'; there are two
checks / unit (pull_request) Successful in 2m32s
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 17:10:42 +02:00
glenn schrooyen 2983d7c3b0 Merge remote-tracking branch 'origin/release/1.0' into TEST-06
checks / unit (pull_request) Canceled after 0s
2026-08-30 17:05:35 +02:00
glenn schrooyenandClaude Opus 5 611d3dbcdf TEST-06 review follow-ups: two notification surfaces, the real ordering boundary, the schema bounds
1. notes_of() could not tell this guard's alarm from anybody else's. It
   selected by SERVICE, so against #12's app/ (which adds
   goodwe_output_clamp) eight assertions went red, AC1's core check among
   them. Blanket id-keying is not the repair and was measured, not
   guessed:

       selector                    vs #12's app/   id renamed
       by service (as committed)     8 red           1 red
       by id alone                   3 red           6 red
       by id or title (shipped)      3 red           1 red

   all_notes_of() is the whole surface; notes_of() is this guard's,
   recognised by the id it should carry OR the title it writes - the `or`
   is what keeps the one assertion whose subject IS the id able to fail on
   its own. The three surface-wide claims stay surface-wide, each with a
   comment naming which surface it is about and why the next guard's
   author must decide rather than narrow them. They are the three that go
   red against #12, which is the correct signal.

2. The ordering comment named the wrong boundary. N3 - moving the call to
   immediately before write_setpoint() - is green and correctly so:
   self.target is assigned two lines earlier, write_setpoint() clamps only
   a local and can skip the write entirely. So the invariant is "after
   `self.target = resolution.target_w`", and the detector grades pre-clamp
   INTENT, not the wire. Corrected in test_freeze.py and in main.py's own
   note above the call (comment-only; I merge second and own the
   conflict). N8 - moving the call above the assignment - is RED 4.

3. The schema range's own bounds are now pinned. int(60,3600) ->
   int(1,86400) survived green: an operator could set meter_freeze_s:
   86400 and the guard is dead with nothing red. Both bounds are
   re-derived rather than restated.

4. find_hwsim() crashed the whole suite on a checkout one level below the
   root (HERE.parents[1] -> IndexError, reproduced at C:/goodwe_controller).
   Guarded. And part 3 now names its transport in the summary: the rig
   hwsim and the stub are not equivalent - the rig path failed 1 run in 3
   - so a green log has to say which one backed it.

Also: the "revived transport re-rails" check is labelled a PRECONDITION
like its sibling; freeze_rows() records that flipping p1_enabled exercises
the row's content and never its gate; and the note about the deleted
assertion is corrected - it was REDUNDANT, not undecidable. The reviewer
falsified it in one line (move the hass.call above `if not fired: return`,
RED 9). "I could not construct a falsifier, therefore it cannot fail" was
exactly the inference this file exists to distrust.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 17:05:28 +02:00
glenn schrooyenandClaude Opus 5 46383c5ae5 Merge release/1.0 (CI-01) into SAFETY-03 so the required check can run
checks / unit (pull_request) Successful in 2m32s
Branch protection on release/1.0 now requires the context
`checks / unit (pull_request)`, and CI-01's workflow arrived after this
branch was cut - so no run had ever been triggered for this PR and the
required context would have sat pending forever. Clean merge, no
conflicts: .gitattributes, .gitea/ci/Dockerfile and
.gitea/workflows/checks.yml only. No add-on source or check is touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 16:03:32 +02:00
admin 5e966ca59f CI-01: this repository's first automated check (#13) 2026-08-30 16:00:42 +02:00
glenn schrooyenandClaude Opus 5 4e66583a52 SAFETY-03 review fixes: both clamp stages always run, and two checks that could not fail
1. BEHAVIOURAL, and a regression this PR introduced. clamp_to_rating() returned
early from the max_w stage, so the device bound was applied only when the rating
bound had NOT fired - the bigger the overshoot, the less the guard did. At max_w
5000 against a +-4000 device, +9999 emitted +5000 W, outside the device range,
while +4500 was correctly held to +4000. It undid the pre-PR guarantee "never
send a value the device will reject outright" and undercut this module's own
case for max_w-not-min(), which rests on that stage catching a validation that
did not run. Both stages now always run; the result names both bounds when both
bite (max_w+device). Asserted over a 492-point sweep, because the defect was
invisible to any single-value check sitting inside one stage.

2. The hysteresis check issued range(CLEAR_CYCLES - 1) clean cycles, which at
CLEAR_CYCLES = 1 issues zero, passes, and prints "0 clean cycles do NOT clear
it" - green for the chatter setting the constant exists to prevent. Now: ONE
clean cycle must not clear the alarm, a literal that does not move with the
constant, and the de-assert count is measured by looping until it clears.

3. The re-assert check stimulated at REASSERT_S + 9, green for any value
including 3600 - the hour of silence the module promises not to produce. Now
stated in wall-clock terms: a loop pinned across the 900 s capacity-tariff
quarter must speak at least 5 times and on no more than 20% of cycles. Pinned in
both directions.

Red confirmed for each: the restored early return (3 checks), CLEAR_CYCLES = 1
(1), REASSERT_S = 3600 (1) and REASSERT_S = 0 (3).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 15:52:09 +02:00
glenn schrooyenandClaude Opus 5 c34b5a2922 TEST-06: close the three gaps that survived SAFETY-18's suite green
None of the three is a bug in the shipped code. They are gaps in what the
suite could detect, and the next person to touch freeze.py had less
protection than the passing count implied.

1. WHERE check_meter_frozen() runs in cycle(). Moving it to the top left
   the whole file green. Pinned by CONSEQUENCE, not by source order, so a
   refactor that keeps the semantics stays green:
     - the alarm must land on the SAME cycle the command reaches the rail
       (at the top it grades the previous command against this cycle's
       meter and arrives a cycle late);
     - the dead-poll-task composition: poll task dies, stale_input_s is
       crossed, the arbiter commands 0 W, and on THAT cycle the alarm is
       already clear - because the detector ran after the 0 W write.
   wired() now returns a per-cycle trace, which is what makes "on which
   cycle" an observation rather than a hope.

2. The NOT COVERED status row. The old check only asserted that an
   uncovered transport is SILENT, which a page claiming `armed` on a guard
   that cannot run also satisfies. The string is now asserted in both
   directions: the uncovered row must say NOT COVERED, name the
   meter_source and homewizard_local, and warn; the covered row must still
   say armed, or "does not say armed" would be satisfied by deleting the
   armed branch.

3. meter_freeze_s. Pinned in test_validate.py by MAINT-04's regex
   technique (no PyYAML in the image), and in test_freeze.py by its
   consequences: the shipped value drives the replays, must stay inside
   the 900 s billing quarter, and 3600/hold_s must stay inside the shipped
   deadband. A Controller built with the key ABSENT must land on the same
   number, which pins main.py's fallback without touching CFG-03.

All three demonstrated red before being accepted green, and every new
check was mutated to confirm it can fail; one candidate assertion ("no new
notification while parked at 0 W") was DELETED because no mutation could
break it, and replaced by the exact notification count across a revived
transport, which can.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 15:50:08 +02:00
glenn schrooyenandClaude Opus 5 9c1a23328a CI-01: this repository's first automated check
checks / unit (pull_request) Successful in 2m39s
Before this commit `admin/goodwe-addon` had no `.gitea/workflows/` directory at
all. Eight runnable test files - `test_loop.py` alone drives the real
`run_control()` for 93 s of wall clock - and not one of them had ever been run
by a machine. Every merge here was a human reading a diff, and the product
owner's requirement that a green CI gate a merge could not be met on a
repository with no CI to be green.

One job, `unit`, with no `paths:` filter, so it reports on every PR and can
therefore be a REQUIRED status check: Gitea leaves a required context it never
receives pending forever, which is the failure mode on the other side of this
ticket. Concurrency is scoped per PR from the start rather than to a bare group
name - the bare name is what let the infra repo's run 521 be superseded while
still pending, so its four jobs concluded `cancelled` with `started_at` at the
Unix epoch and its PR merged on no evidence at all.

The tests run in `.gitea/ci/Dockerfile`: `alpine:3` plus `py3-aiohttp` and
`py3-paho-mqtt` from apk, matching goodwe_controller/Dockerfile exactly, because
pip would install glibc wheels of a library the shipped image gets from Alpine.
The runner itself cannot host them - bare python3, no aiohttp, no pip - and
mutating a shared long-lived runner with `apk add` is invisible to anyone
reading this repo.

Two things measured while building it and recorded in the file rather than
learned again: the checkout must sit two levels below the mount root or
test_freeze.py's `find_hwsim()` dies on `IndexError: 1` before its first
assertion, and test_freeze's hwsim section is silently absent here because
admin/goodwe is private - so its PASS is a weaker claim than it looks, and the
file says so.

Verified green on release/1.0 content before this workflow was written: 8 of 8
files pass, ~4 minutes.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 15:46:30 +02:00
glenn schrooyenandClaude Opus 5 c040aac4b8 SAFETY-03: alarm when a computed setpoint exceeds the rating, do not just clip it
The clamp was never the missing half. specs.md 10.3 records an unclamped
integrator climbing ~130 W per 4 s past 10 kW and reporting 14 768 W pinned at
the 5 kW rail; clipped silently that is a flat, legal-looking 5000 W hold and
nothing says the loop asked for three times it.

write_setpoint() - the one path every write takes - now clamps to the VALIDATED
max_w and reports whether the raw value differed; check_output_clamp() raises
OUTPUT_CLAMP as a notification, an ERROR, an event row and a red status banner.
Not a trip: the clamped value is written and the loop keeps running.

The rating is max_w and nothing is min()ed at runtime - CFG-01 already refuses a
max_w outside the device range at startup. The device range is applied second as
defence in depth; it cannot bite after a successful validation, so if it ever
does it alarms too and names the bound. No new config key.

Decision grew i_clamped / clamped booleans, and that is the load-bearing part:
`reason` is one string that slew-limiting and the saturation freeze overwrite,
so an alarm keyed on it is silent on exactly the cycles a winding loop produces.
Mutating main.py back onto the string drops the 10.3 replay from 2 engagements
to 0.

Distinct from saturation by construction - no shared reason code, notification
id, status row or counter - and checked in the negative, after first asserting
the saturation freeze really did engage.

Two things found by running it rather than by reading it: a row per engagement
flushed the 40-row event log and evicted SAFETY-18's own METER FROZEN? row (now
coalesced per episode with an exact count), and a naive clamp turns a nan into a
command at the full rating because every comparison against nan is False.

test_clamp.py is new: assert-based, no framework. Six author mutations
reproduced red, including "clamp kept, alarm deleted". Two of the check's own
hypotheses about the freeze/clamp interaction were refused by its sweep and
rewritten to what it measured.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 15:22:22 +02:00
admin 0cdaa3bd3e SAFETY-18: alarm on a meter frozen at a wrong-but-fresh value (#11)
A meter answering 200 OK with a document that never changes reads healthy to every freshness mechanism in the stack while the loop rails. Detected by a conjunction - unchanged_s >= meter_freeze_s AND |command| within 5% of max_w - which fails in both directions for independent reasons. Alarm only: no claim, no latch, no 0 W.

Reviewed: all six author mutations reproduced red (redder than reported), four more added, three survivors recorded for follow-up. Capture figures re-derived independently. Attack point 4 (dead poll task) measured, not just reasoned. Known follow-up: a device rating that clips max_w by >5% silently disarms the rail term while the status page says armed - does not affect the live install, where dev_max == max_w == 5000.
2026-08-30 03:20:38 +02:00
glenn schrooyenandClaude Opus 5 7cde5d862a Merge release/1.0 into SAFETY-18 - CHANGELOG only
MAINT-04 (#10) landed on release/1.0 mid-review, so both branches had
prepended a stanza. config.yaml and DOCS.md auto-merged clean; only the
CHANGELOG needed a hand. Both stanzas are kept verbatim, MAINT-04's
Unreleased above the new 0.5.2 - no text from either author edited.
MAINT-04 is unreleased and 0.5.2 is being cut here, so a release manager
may want to fold the two; that is an editorial call, not a reviewer's.

Full suite green on the merged tree: arbiter, control, loop, maintenance,
p1, validate, watchdog, freeze.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 03:20:26 +02:00
admin b0a17474a3 MAINT-04: refuse a maintenance charge the ceiling cannot deliver (#10)
Rule 6 and the default change verified; four claimed mutations plus six of my own all reproduce red. The cross-file default divergence is now pinned by a check that fails in both directions, including when someone closes it - verified against MaintConfig-only, one-call-site-refactored, both-refactored and one-literal-silently-changed.
2026-08-30 03:01:14 +02:00
glenn schrooyenandClaude Opus 5 ffb8ec6373 MAINT-04 review: pin the default divergence with a check, not a comment
validate.py's comment said "if config.yaml's value moves, move this and
main.py's together" and nothing enforced it - a comment where a check
belonged, in a PR that elsewhere proves it knows the difference.

test_validate.py now reads main.py and maintenance.py directly and asserts
the divergence EXACTLY AS IT STANDS: config.yaml/validate.py at 2000,
main.py's two fallbacks and MaintConfig's dataclass default at 2500. It
records the mismatch rather than demanding it be closed, so it passes today
and goes red if either side moves - including when somebody closes it in
main.py, at which point the check and validate.py's block are deleted
together. Nothing in a file another ticket owns is touched.

The consequence is asserted through the real code as well as the literals:
with the key absent the validator accepts, MaintConfig builds 2500 W against
a 2000 W ceiling, and the arbiter resolves it to 0 W as a contradiction -
the bug rule 6 exists to catch, passing rule 6. Production-unreachable (the
Supervisor always supplies every key) but fully reachable from sim/inject.py
and the tests, which is where anyone debugging maintenance works.

Also: a CHANGELOG section for the upgrade path, covering both the case where
the Supervisor re-derives the default and the case where it persisted the
old one, since which applies was not verifiable without probing the live
install. And maintenance.py's timeout comment said 13.5 kWh where everything
else says 13.8 (300 Ah x 51.2 V, DoD 90); SAFETY-18 does not touch that file.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:51:40 +02:00
glenn schrooyenandClaude Opus 5 0ba3a200fe SAFETY-18: verify on the real rig, and record what it showed
AC3 says "verified on the rig". The previous commit drove hwsim in-process
because `riglock status` reported UNKNOWN - which is the tool declining to
observe, not an observation. riglock shells out to the local docker CLI; on a
Windows host without DOCKER_HOST that resolves to a Docker Desktop npipe which
is not running, and the result is indistinguishable from a genuinely absent rig.
The rig was up the whole time. With DOCKER_HOST=ssh://homelab@192.168.2.147 it
reads FREE.

Re-run under sim/riglock.py against the real goodwe-sim compose project, with
the shipped modules staged into goodwe-sim-plant so they poll that container's
own hwsim while plantsim drives it. Both phases passed, lock released cleanly.

The rig produced a result the in-process stub could not, and it strengthens the
design rather than merely confirming it: in the NEGATIVE twin - +8000 W of house
load, healthy meter, correctly railed command - `active_power_w` did not move at
all, sitting at exactly 10130.0 W for 26 consecutive polls. The only thing
keeping `unchanged_s` at 0.0 s was the kWh registers advancing.

So the register terms in measurement_fingerprint() are not belt-and-braces for
this detector, they ARE the negative case: fingerprinted on the power figure
alone it would have raised a false alarm on a healthy meter under a real load,
which is precisely how a safety guard gets switched off. Recorded in freeze.py
so nobody simplifies the fingerprint without meeting that run first.

No behaviour change - documentation and the harness note only.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:49:55 +02:00
glenn schrooyenandClaude Opus 5 7aa1bd052e SAFETY-18: a meter frozen at a wrong-but-fresh value now raises an alarm
A meter that answers 200 OK with a stale document forever is ARRIVING on every
poll, so every freshness mechanism in the stack reads it as healthy while the
loop integrates a constant error and rails: 360/135/75 s at the live install's
max_w: 5000 for a meter frozen at 350/1000/>=3000 W. Fifteen minutes of a 5 kW
unattended import sets the month's billed capaciteitstarief peak.

The detector is a conjunction, not the bare unchanged_s threshold TEL-05
measured and rejected:

    unchanged_s >= meter_freeze_s   AND   |command| within 5 % of max_w

Both terms already existed and were already on the status page, and they fail
for independent reasons: at the converged point the command is nowhere near the
rail, and at the rail against a real load the kWh registers move in seconds. At
the shipped 300 s the relation is structural rather than a margin - the slowest
a healthy 1 Wh register can tick and still look unchanged is 12 W, which is
inside the 15 W deadband, so the command there is parked at 0 W.

Notification only, deliberately: an HA persistent notification with a fixed
notification_id, an ERROR log line, a UI event and a red status row. No claim,
no latch, no 0 W. A false trip parks the battery; a false notification costs an
alert. Only meter_source: homewizard_local is covered - the status page says
NOT COVERED elsewhere rather than pretending the guard is armed.

DOCS.md states the capacity-tariff exposure this does NOT close: peak_cap_w caps
maintenance charging and nothing caps the loop. That cap is SAFETY-07.

test_freeze.py grades both directions and was verified by breaking what it
watches (six mutations, all red): silent over the committed 40-minute converged
capture, silent over an hour of TEL-05's low-power case where the rejected bare
threshold is shown to fire, alarming on a genuinely frozen meter driven over
real HTTP through the real HomeWizardLocalSource (the rig's own hwsim freeze
fault when reachable), silent on the same railed command against a meter that is
still moving, and asserting on the service call that leaves Controller.cycle()
rather than on the watchdog's own flag.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:39:54 +02:00
glenn schrooyenandClaude Opus 5 878a6ce452 MAINT-04: refuse a maintenance charge the ceiling cannot deliver
config.yaml shipped max_w 2000 against maintenance_charge_w 2500. The
cheap-window shaping files Claim.limit(hi = -maintenance_charge_w) against
the supervised SAFETY limit's lo = -max_w, so lo > hi - the arbiter's
clause 3, correctly resolved to 0 W and logged as a CONTRADICTION.
Maintenance silently never charged in a cheap window on a default install,
and the only evidence read like a bug in the arbiter rather than like the
two numbers the operator set.

validate_startup_config() now refuses maintenance_charge_w > max_w, the
same shape as CFG-01's sign_disagree_w >= max_w. Equality is reachable
(-max_w is a single valid point) and is not refused. Demonstrated by
starting the add-on on the pre-fix pair: exit 78 and the refusal banner.

maintenance_discharge_w was checked rather than assumed and is NOT the same
case: the drain phase OWNS the actuator (Claim.set at P_MAINTENANCE), so
the ceiling clamps it to +2000 W and the arbiter's explain() names the
clamp every cycle. Loud, and it still moves energy - warned, not refused.

The shipped maintenance rates drop to 2000 so the defaults pass the rule;
max_w was deliberately not raised, because it is the supervised safety
ceiling. test_validate.py now reads config.yaml itself, so a default the
validator refuses cannot ship again.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:28:09 +02:00
admin bb64f8fdd7 SAFETY-02 follow-up: persist the latch, and make the gate assertion bite (#9) 2026-08-28 23:09:27 +02:00
glenn schrooyenandClaude Opus 5 e40eb0768d SAFETY-02: the P_PEAK assertion was pinning the test's copy of the gate
Review finding 2, and it is the same duplication `disagrees()` just removed, so
it gets the same fix rather than a follow-up card.

`following_from()` in test_watchdog.py was a TRANSCRIPTION of the gate in
main.py, carrying "keep the two in step" as an instruction - which is exactly the
arrangement that does not keep two things in step. Measured: editing the shipped
gate alone to `winner in ("loop", "peak")` left every suite green while the
watchdog went blind for the duration of every peak event. The row whose whole job
is to force whoever lands peak shaving to come and change an expectation did not
do that.

The expression is now `watchdog.loop_is_following()`, called by main.py and by
the test. One definition, two callers, same reasoning as `disagrees()`: the copy
that drifts is always the one in the harness doing the grading.

⚠️ AND EXTRACTING IT WAS NOT SUFFICIENT - the drift proof still came out green
after the extraction, which is why it was worth running rather than assuming. The
realistic P_PEAK row has peak shaving asking for MORE than the loop, so the
magnitude term rejects it whatever `winner` says and masks the term under test. A
second row with peak asking for LESS makes `winner` the only deciding term. With
that row, widening the shipped gate fails two checks; without it, none.

Also enforcing the write ordering that was documented and not asserted: swapping
the two `store.set` calls passed everything. A store that fails the second write
now proves the property the ordering exists for - a crash mid-trip leaves a
reason with no latch, never a latch with no explanation. Swapping them now turns
that check red.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:59:46 +02:00
glenn schrooyenandClaude Opus 5 cc4e88490b SAFETY-02 review: a latch that a restart clears is not a latch
BLOCKER. `auto` was persisted and `sign_wd.tripped` was not, so reconstructing
the Controller against the same store - which is what a container restart does -
brought it back ARMED, into the same fault, unattended: tripped=False, banner
back to NOT READY, and it resumed commanding -1000 then -2000 W before
re-tripping 180 s later. "Restart the add-on" is the first thing an operator
looking at a FAILSAFE banner and a 0 W inverter will try, and under a supervisor
that restarts a crashed add-on it is a loop of three-minute wrong-direction
bursts. DOCS.md's "it does not clear itself" was false across a restart.

`sign_tripped` and `sign_reason` are Store keys now, beside the maintenance
state and for the reason store.py's own docstring gives. Written the moment the
trip happens - reason first, flag second, so a crash between the two can never
persist a latch with no explanation - restored in Controller.__init__, cleared
only by the operator's start. The regression is covered: reverting the restore
fails seven checks in test_watchdog.py.

Review follow-ups, no behaviour change:

- The arming gate is tested against the REAL arbiter. It is the decision the
  ticket turns on and it was asserted in three comment blocks and verified by
  nothing - every case passed `following` in as a literal. Twelve claim
  configurations now derive it from resolve(), including the redirect case
  `winner == "loop"` alone would have got wrong and the `lo` limit that raises
  magnitude without flipping sign.
- The MQTT `status: "failsafe"` value is tested. The check that claimed to cover
  it restated the line above it and never touched the payload.
- The worked example described a config that does not ship: at the defaults
  maintenance_charge_w 2500 against max_w 2000 is an arbiter contradiction and
  0 W, not a -2500 W charge. Rewritten at 1500 W. The contradiction is a real
  pre-existing bug - a default cheap-window maintenance charge silently never
  happens - filed separately and deliberately not fixed here.
- Forward hazard recorded at the gate: `winner == "loop"` disarms the watchdog
  under any higher-priority SET, and a peak-shaving strategy at P_PEAK IS
  grid-following in sign, so it would blind this for every peak event.
- disagrees() is public so the replay harness stops carrying its own copy of the
  predicate it grades.
- held_s takes the clock instead of reading one.
- The two limits are now each stated in both places rather than one each.
- The no-false-positive argument is tied to control.py's freeze permitting the
  command to cross zero; under the shrink-only encoding control.py records as
  rejected, this would false-trip on a load step.
- Measured figures corrected: 93.4 % / 4212 of 17280, per-cluster
  0.3/0.9/10.5/0.0, and the near-circularity of those figures is now stated
  rather than leaned on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:33:15 +02:00
admin 2513ba1f12 SAFETY-02: the sign-disagreement watchdog (#8) 2026-08-28 21:55:52 +02:00
glenn schrooyenandClaude Opus 5 9aed43990b SAFETY-02: a loop can be fresh, tracking and inside its rating and still push the wrong way
The stale-input watchdog asks whether the meter is still talking. The saturation
freeze asks whether the inverter can follow. The output clamp asks whether the
number is too big. A loop can pass all three while charging the battery out of
the grid, because the only thing wrong is the sign.

On 2026-08-20 a commercial controller did exactly that four times in one day,
for up to 77 minutes at a stretch, reaching a commanded -14 768 W against a
±5000 W inverter. app/watchdog.py compares the emitted setpoint against the
authoritative P1 figure and, when they oppose each other with both over 300 W
for 180 s continuously, files a failsafe SET claim at P_SAFETY, commands 0 W and
latches there until an operator starts control again.

Validated against that day rather than against an argument: sim/replay_sign.py
in the infra repo drives this module over the committed captures of both
2026-08-20 and the healthy 2026-08-23 and reaches 18 trips on the fault day -
every one inside a window NOTES.md §4.7 accounts for - and 0 on the healthy day.
The four episodes do share one signature: 0.3 / 0.9 / 10.5 / 0.0 % sign
agreement inside them against 92.9 % healthy.

Three decisions the ticket could not make:

- It is DISARMED whenever the grid-following loop is not what is driving. Sign
  agreement is a property of a loop that follows the meter, and a maintenance
  grid charge opposes the meter by design - 2500 W of charge into a house
  drawing 500 W is +3000 W on the meter against a -2500 W command, for hours.
  The gate tests the emitted number, not the winning claim's name, because a
  limit claim can let the loop "win" and still replace its value.
- The trip LATCHES. Commanding 0 W removes the command side of the comparison,
  so the disagreement always clears the moment the trip works.
- sign_disagree_w at or above max_w is refused at startup. The arbiter never
  lets a command exceed max_w, so such a threshold leaves the watchdog incapable
  of firing while the status page still reports it armed.

What it does not catch, said out loud: an inverter that ACTS opposite to its
command moves the meter further the same way, leaving command and meter in
agreement. That is the saturation freeze's job.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:51:35 +02:00