glenn schrooyenandClaude Opus 5 d57122ec74
checks / unit (pull_request) Successful in 3m36s
DATA-02: a real Belgian price year, so AC4 stops being unmeetable
OPT-04 reported AC4 - "net-positive across 12 months of replayed prices" -
as NOT MET and replayed a synthetic year, because scenarios/ held only P1
meter captures. Right call, wrong diagnosis: the criterion was being carried
beside a 30-day METER criterion as though both needed waiting. EPEX BE
day-ahead is public data, not a capture. It needed a fetch.

8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, canonical three
fields. Licence checked BEFORE committing: Energy-Charts publishes the BE
zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under
private-use-only terms, so this one is redistributable with attribution. The
fetcher refuses to write a file whose per-response license_info stops saying
so. Cross-checked against SMARD's own 4996/DE: 96 of 96 quarter-hours, max
difference 0.00 EUR/MWh.

Raw wholesale, and the file says so. all_in: false, with the markup/tax
assumption carried as numbers to APPLY rather than numbers applied -
TARIFF-02's trap in data form. Section 7B applies it in one visible place and
asserts arithmetically that its additive terms cancel out of every daily
spread, so the trade count turns on the VAT multiplier alone; the raw replay
is run too, so how much rests on the guess is reported (110 vs 88).

DST by construction: iterate in UTC, render through price.brussels().
2025-10-26 is 25 points, 2026-03-29 is 23, verified by counting per Brussels
day rather than asserting 24, and by checking October's 02:00 appears twice
at two offsets with two prices while March's never appears. Both bugs the
point-and-gap accounting caught were real: a UTC-bounded window made the
first day 22 hours, and an inclusive-end off-by-one dropped the last day
silently. A day nobody asked for is not a day with no prices.

THE RESULT, AT THE SHIPPED DEFAULT, WHATEVER IT IS. At 0.10 widened 1.5x to
0.1500: 110 round trips, +24.88 EUR net of the cycle cost. Unwidened, 173.
Nothing tuned - the threshold and the 2.5/1.5 factors are untouched.

And what the owner's decision now has under it: the four reports that a
static ~0.0840 spread does not clear 0.10 all STAND. What was missing is that
a dynamic site clears the widened requirement on 121 of 365 days, median
all-in spread 0.1130, so a median day would clear at 0.0754 - 156 trips,
+35.42 EUR. Reported, not applied.

The synthetic year stays, because the real one cannot grade section 17: not
one of 365 days has a negative DEAREST hour, so a zero there counts something
that could not happen. 7B asserts that degeneracy rather than reporting the
zero.

Size measured, not assumed: 893 KB plain but 74.6 KB as a git object against
56.5 KB gzipped. Git already compresses; 18 KB is not worth making the
provenance block - the licence claim a reviewer must check - unreadable in a
diff.

Nothing wired into the add-on; generic_dayahead is still the live path.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-31 11:01:42 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.