Compare commits

..
19 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5 ffb8ec6373 MAINT-04 review: pin the default divergence with a check, not a comment
validate.py's comment said "if config.yaml's value moves, move this and
main.py's together" and nothing enforced it - a comment where a check
belonged, in a PR that elsewhere proves it knows the difference.

test_validate.py now reads main.py and maintenance.py directly and asserts
the divergence EXACTLY AS IT STANDS: config.yaml/validate.py at 2000,
main.py's two fallbacks and MaintConfig's dataclass default at 2500. It
records the mismatch rather than demanding it be closed, so it passes today
and goes red if either side moves - including when somebody closes it in
main.py, at which point the check and validate.py's block are deleted
together. Nothing in a file another ticket owns is touched.

The consequence is asserted through the real code as well as the literals:
with the key absent the validator accepts, MaintConfig builds 2500 W against
a 2000 W ceiling, and the arbiter resolves it to 0 W as a contradiction -
the bug rule 6 exists to catch, passing rule 6. Production-unreachable (the
Supervisor always supplies every key) but fully reachable from sim/inject.py
and the tests, which is where anyone debugging maintenance works.

Also: a CHANGELOG section for the upgrade path, covering both the case where
the Supervisor re-derives the default and the case where it persisted the
old one, since which applies was not verifiable without probing the live
install. And maintenance.py's timeout comment said 13.5 kWh where everything
else says 13.8 (300 Ah x 51.2 V, DoD 90); SAFETY-18 does not touch that file.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:51:40 +02:00
glenn schrooyenandClaude Opus 5 878a6ce452 MAINT-04: refuse a maintenance charge the ceiling cannot deliver
config.yaml shipped max_w 2000 against maintenance_charge_w 2500. The
cheap-window shaping files Claim.limit(hi = -maintenance_charge_w) against
the supervised SAFETY limit's lo = -max_w, so lo > hi - the arbiter's
clause 3, correctly resolved to 0 W and logged as a CONTRADICTION.
Maintenance silently never charged in a cheap window on a default install,
and the only evidence read like a bug in the arbiter rather than like the
two numbers the operator set.

validate_startup_config() now refuses maintenance_charge_w > max_w, the
same shape as CFG-01's sign_disagree_w >= max_w. Equality is reachable
(-max_w is a single valid point) and is not refused. Demonstrated by
starting the add-on on the pre-fix pair: exit 78 and the refusal banner.

maintenance_discharge_w was checked rather than assumed and is NOT the same
case: the drain phase OWNS the actuator (Claim.set at P_MAINTENANCE), so
the ceiling clamps it to +2000 W and the arbiter's explain() names the
clamp every cycle. Loud, and it still moves energy - warned, not refused.

The shipped maintenance rates drop to 2000 so the defaults pass the rule;
max_w was deliberately not raised, because it is the supervised safety
ceiling. test_validate.py now reads config.yaml itself, so a default the
validator refuses cannot ship again.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:28:09 +02:00
admin bb64f8fdd7 SAFETY-02 follow-up: persist the latch, and make the gate assertion bite (#9) 2026-08-28 23:09:27 +02:00
glenn schrooyenandClaude Opus 5 e40eb0768d SAFETY-02: the P_PEAK assertion was pinning the test's copy of the gate
Review finding 2, and it is the same duplication `disagrees()` just removed, so
it gets the same fix rather than a follow-up card.

`following_from()` in test_watchdog.py was a TRANSCRIPTION of the gate in
main.py, carrying "keep the two in step" as an instruction - which is exactly the
arrangement that does not keep two things in step. Measured: editing the shipped
gate alone to `winner in ("loop", "peak")` left every suite green while the
watchdog went blind for the duration of every peak event. The row whose whole job
is to force whoever lands peak shaving to come and change an expectation did not
do that.

The expression is now `watchdog.loop_is_following()`, called by main.py and by
the test. One definition, two callers, same reasoning as `disagrees()`: the copy
that drifts is always the one in the harness doing the grading.

⚠️ AND EXTRACTING IT WAS NOT SUFFICIENT - the drift proof still came out green
after the extraction, which is why it was worth running rather than assuming. The
realistic P_PEAK row has peak shaving asking for MORE than the loop, so the
magnitude term rejects it whatever `winner` says and masks the term under test. A
second row with peak asking for LESS makes `winner` the only deciding term. With
that row, widening the shipped gate fails two checks; without it, none.

Also enforcing the write ordering that was documented and not asserted: swapping
the two `store.set` calls passed everything. A store that fails the second write
now proves the property the ordering exists for - a crash mid-trip leaves a
reason with no latch, never a latch with no explanation. Swapping them now turns
that check red.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:59:46 +02:00
glenn schrooyenandClaude Opus 5 cc4e88490b SAFETY-02 review: a latch that a restart clears is not a latch
BLOCKER. `auto` was persisted and `sign_wd.tripped` was not, so reconstructing
the Controller against the same store - which is what a container restart does -
brought it back ARMED, into the same fault, unattended: tripped=False, banner
back to NOT READY, and it resumed commanding -1000 then -2000 W before
re-tripping 180 s later. "Restart the add-on" is the first thing an operator
looking at a FAILSAFE banner and a 0 W inverter will try, and under a supervisor
that restarts a crashed add-on it is a loop of three-minute wrong-direction
bursts. DOCS.md's "it does not clear itself" was false across a restart.

`sign_tripped` and `sign_reason` are Store keys now, beside the maintenance
state and for the reason store.py's own docstring gives. Written the moment the
trip happens - reason first, flag second, so a crash between the two can never
persist a latch with no explanation - restored in Controller.__init__, cleared
only by the operator's start. The regression is covered: reverting the restore
fails seven checks in test_watchdog.py.

Review follow-ups, no behaviour change:

- The arming gate is tested against the REAL arbiter. It is the decision the
  ticket turns on and it was asserted in three comment blocks and verified by
  nothing - every case passed `following` in as a literal. Twelve claim
  configurations now derive it from resolve(), including the redirect case
  `winner == "loop"` alone would have got wrong and the `lo` limit that raises
  magnitude without flipping sign.
- The MQTT `status: "failsafe"` value is tested. The check that claimed to cover
  it restated the line above it and never touched the payload.
- The worked example described a config that does not ship: at the defaults
  maintenance_charge_w 2500 against max_w 2000 is an arbiter contradiction and
  0 W, not a -2500 W charge. Rewritten at 1500 W. The contradiction is a real
  pre-existing bug - a default cheap-window maintenance charge silently never
  happens - filed separately and deliberately not fixed here.
- Forward hazard recorded at the gate: `winner == "loop"` disarms the watchdog
  under any higher-priority SET, and a peak-shaving strategy at P_PEAK IS
  grid-following in sign, so it would blind this for every peak event.
- disagrees() is public so the replay harness stops carrying its own copy of the
  predicate it grades.
- held_s takes the clock instead of reading one.
- The two limits are now each stated in both places rather than one each.
- The no-false-positive argument is tied to control.py's freeze permitting the
  command to cross zero; under the shrink-only encoding control.py records as
  rejected, this would false-trip on a load step.
- Measured figures corrected: 93.4 % / 4212 of 17280, per-cluster
  0.3/0.9/10.5/0.0, and the near-circularity of those figures is now stated
  rather than leaned on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:33:15 +02:00
admin 2513ba1f12 SAFETY-02: the sign-disagreement watchdog (#8) 2026-08-28 21:55:52 +02:00
glenn schrooyenandClaude Opus 5 9aed43990b SAFETY-02: a loop can be fresh, tracking and inside its rating and still push the wrong way
The stale-input watchdog asks whether the meter is still talking. The saturation
freeze asks whether the inverter can follow. The output clamp asks whether the
number is too big. A loop can pass all three while charging the battery out of
the grid, because the only thing wrong is the sign.

On 2026-08-20 a commercial controller did exactly that four times in one day,
for up to 77 minutes at a stretch, reaching a commanded -14 768 W against a
±5000 W inverter. app/watchdog.py compares the emitted setpoint against the
authoritative P1 figure and, when they oppose each other with both over 300 W
for 180 s continuously, files a failsafe SET claim at P_SAFETY, commands 0 W and
latches there until an operator starts control again.

Validated against that day rather than against an argument: sim/replay_sign.py
in the infra repo drives this module over the committed captures of both
2026-08-20 and the healthy 2026-08-23 and reaches 18 trips on the fault day -
every one inside a window NOTES.md §4.7 accounts for - and 0 on the healthy day.
The four episodes do share one signature: 0.3 / 0.9 / 10.5 / 0.0 % sign
agreement inside them against 92.9 % healthy.

Three decisions the ticket could not make:

- It is DISARMED whenever the grid-following loop is not what is driving. Sign
  agreement is a property of a loop that follows the meter, and a maintenance
  grid charge opposes the meter by design - 2500 W of charge into a house
  drawing 500 W is +3000 W on the meter against a -2500 W command, for hours.
  The gate tests the emitted number, not the winning claim's name, because a
  limit claim can let the loop "win" and still replace its value.
- The trip LATCHES. Commanding 0 W removes the command side of the comparison,
  so the disagreement always clears the moment the trip works.
- sign_disagree_w at or above max_w is refused at startup. The arbiter never
  lets a command exceed max_w, so such a threshold leaves the watchdog incapable
  of firing while the status page still reports it armed.

What it does not catch, said out loud: an inverter that ACTS opposite to its
command moves the meter further the same way, leaving command and meter in
agreement. That is the saturation freeze's job.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:51:35 +02:00
admin 35856a73ae SAFETY-12: a loop that only thinks when the number changes cannot fail safe (#7) 2026-08-28 21:18:20 +02:00
glenn schrooyenandClaude Opus 5 aae74d7571 SAFETY-12 review: name the safety claim that could not fire, and fix two figures
Review fixes.

A. test_loop.py takes 73 s, not the ~35 s claimed in three places. That number
is the whole defence against a future developer deleting a slow test, so it was
understated by 2x in exactly the place it matters. Corrected - and it is now
~95 s (measured 93 s), because this commit adds the scenario below rather than
trimming windows to make an inconvenient number smaller. Both call sites carry
an instruction to re-measure if the windows change.

B. "242 checks" was test_p1's own count quoted as the total for all five
suites. The real figure is 395 across the five, plus 14 here.

And the finding this PR should have led with. stale_input_s and the
`inputs missing -> 0 W` claim both live INSIDE cycle(), so pre-fix, on a meter
whose value happened to repeat, that claim could not fire at all. Constant
meter, SoC entity dying at t=4 s, one binary:

  pre-fix   final target 220.0 W, reason 'loop -> 220 W'
  post-fix  final target   0.0 W, reason 'safety -> 0 W'

The old controller held 220 W through the whole input outage with its status
line still reading loop -> 220 W, and layer 1 does not cover that on a
`meter_source: off` install - no P1 age sensor is published, so the firmware has
nothing to veto on, while the heartbeat keeps its watchdog fed. The pre-fix
behaviour was not "holds a stale command safely"; it was a failsafe a repeating
meter switched off. Asserted in test_loop.py, both halves.

Three points of reasoning tightened, none of them wrong before:

- the re-tune is unreachable by construction, not merely by the reset: the
  combined cycle rate is max(arrival rate, 1/floor), never the sum, and 1/15 s
  is strictly slower than the ~1/5 s arrival rate. That holds only while the
  floor exceeds the meter's update interval - and the schema minimum of 5 s is
  exactly the reference meter's interval. Flagged for validate.py, not fixed
  here.
- the ~11 s lower bracket is not only a dropped poll: a 5.0 s poller against a
  4.97 s meter beats, so about every 14 minutes the poller steps over an update
  entirely. Reaching 15 s takes a beat-skip AND a failed poll.
- the "freshness is decided upstream" guarantee is transport-conditional. On
  `meter_source: off` the grid figure comes straight from hass.number() with no
  age gate. Running the full law is still right; the claim is narrower than it
  was stated.

The 15 s default is not independently justified - it rests on the firmware's
30 s ingest veto and moves if that ever does. Said beside the constant.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:14:58 +02:00
glenn schrooyenandClaude Opus 5 8cc9438aec SAFETY-12: record the six-minute observation, not just the unit check
test_loop.py proves the property in 35 s. This is the same three scenarios run
for six and three real minutes each, on one binary, and it is what AC2 and AC3
were actually asked for: 1 cycle before vs 24 after on a constant meter with the
command stuck at 220 W against a 350 W import, and byte-identical write
sequences on both the converged and the normally-changing meter.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:48:49 +02:00
glenn schrooyenandClaude Opus 5 96a808a057 HANDOVER: run every suite before deploying, and say why one is slow
The pre-deploy command listed three of the five suites; test_validate and
test_p1 were never added when they arrived. Adds those and test_loop, with a
note that test_loop's ~35 s is the cost of proving a wall-clock property about a
loop that sleeps 1 s a tick rather than a sign something is wrong.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:32:00 +02:00
glenn schrooyenandClaude Opus 5 88cd97cc7a SAFETY-12: the loop thinks on a clock, not only when the number moves
run_control() ran cycle() only when the meter value differed from the previous
poll. A meter that repeats a value therefore ran no control cycles at all -
while the heartbeat kept re-emitting the last command and the firmware kept
putting it on the wire every 2 s. Layer 1 stayed fed and every indicator read
healthy, so a command computed from an old reading went on being executed
through whatever the load did next. TEL-05 measured it: 70 s at a literally
constant 350.0 W, 14 arrivals, zero cycles.

cycle_floor_s (default 15 s) is a deadline on the GAP between cycles, reset by
every cycle whichever trigger fired - not a second scheduler. On a healthy meter
it never elapses, so the cycle rate and the commanded sequence are unchanged;
test_loop.py asserts that by driving the real loop twice on one binary (a huge
cycle_floor_s reproduces the old behaviour) and diffing the writes.

15 s is bracketed: above the ~11 s worst gap on a merely-unlucky healthy meter
(~5 s arrivals, 1 s detection, one dropped poll retried on the next tick), below
meter_max_age_s and the firmware's 30 s ingest veto, and equal to stale_input_s.

A floor cycle runs the full law. Freshness is already decided upstream - past
meter_max_age_s the reading is None, which is a P_SAFETY 0 W claim - and the
integrator advances per cycle, not per second, so bounding the gap bounds the
accumulation.

Not a freeze detector: nothing here decides whether a repeated reading is true.
DOCS.md's "accepted deviation" passage is qualified rather than deleted - the
window is now bounded at 3 x cycle_floor_s instead of open-ended, and its
"nothing accumulates while it is stalled" argument is called out as having
covered windup and not staleness. Same correction in control.py's comment.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:29:16 +02:00
admin e2e331ea54 CFG-01 AC2: refuse to start on a config the lower layer will silently override (#6) 2026-08-28 20:17:55 +02:00
glenn schrooyenandClaude Opus 5 547d796c5d CFG-01 review: widen the rule, refuse the firmware-veto case, fix the stop footgun
Review findings, all confirmed in code before changing anything.

THE RULE DID NOT AUTHORISE ITS OWN BEST REFUSAL. The stated test was
"makes a safety mechanism inoperative, or makes a stated limit untrue",
and a blank setpoint_entity does neither - layer 1 pinning the inverter
at 0 W is the failsafe WORKING, as validate.py's own text admitted. The
real justification is a second, separate category: the add-on is inert
and indistinguishable from healthy. Stated as (a) and (b), with each
refusal tagged, and with both halves explicitly bounded - (a) is not
"any two numbers that could disagree", (b) is not "anything degraded".
Left implicit, the gap is where trivia-creep comes back in.

meter_max_age_s ABOVE THE FIRMWARE'S VETO IS NOW REFUSED. The schema
allows int(5,300); the firmware's threshold is a compile-time
`max_age_s: "30"` and it trips layer 1 at `p1_age_s >= 30`. At 120 the
add-on believes a 119 s reading is fresh and keeps commanding while the
board has already vetoed and is holding at 0 W - healthy meter, running
controller, nothing moving. Structurally identical to the max_w case,
and unlike max_w it is settable on this install, so the headline
behaviour finally has a live demonstration. That firmware file's own
comment says a lower bound on this "belongs in CFG-01, not here".

Only ABOVE is refused: below the veto the add-on gives up first, which
is fail-safe and visible on its own status page. Scoped to P1 being
enabled, because meter_max_age_s governs nothing otherwise.
FIRMWARE_INGEST_VETO_S cannot be imported from a compile-time YAML
substitution, so it carries a note on the single direction in which it
can go stale - and a warning that TEL-06 is editing `ingest_stale`, so a
matching integer may stop meaning a matching rule.

stop= WAS A LIVE FOOTGUN. It defaulted to None, which made a Controller
that cannot stop itself the DEFAULT one. On the late-refusal path that
meant: log the banner, return, and leave the process alive forever with
no control loop and no exit - the exact "inert but looks healthy"
failure this module exists to refuse. Now required and keyword-only, so
the broken shape does not construct; test_p1.py's five call sites pass
an Event.

That whole path had no test and no live demo. It has one now: it drives
run_control() against a device that only reports a narrower range once
the loop starts, and asserts it refuses, signals, returns, and writes
NOTHING - plus the converse, that an agreeing device leads to real
writes. This also covers the max_w composition that cannot be reached
through the Supervisor on the live install.

max_w <= 0 is refused. Schema-blocked in production, but
validate_startup_config() is the simulation suite's entry point too, and
a non-positive max_w inverts the arbiter's supervised bounds into a
contradiction that reads as a safety trip rather than a typo.

Verified live 2026-08-28 (backup goodwe_controller-cfg01r2-1787940076):
meter_max_age_s 120 refused with a message naming 120, 30, and THE
FIRMWARE WINS; no traceback; add-on restored byte-exact and running.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:05:10 +02:00
glenn schrooyenandClaude Opus 5 fc9bd89dca CFG-01: refuse to start on a configuration that cannot be honoured
main.py used to read the setpoint device's own +-5000 W rating, notice a
configured max_w above it, log one WARNING, and run anyway with
write_setpoint() quietly clamping. The operator's stated ceiling was never
the real ceiling and the only evidence had scrolled off the log. specs
§1.5 is explicit that such a config is refused at startup, not survived at
runtime.

validate_startup_config() runs in amain() before the broker, the web
server or any task exists, so a refusal cannot leave half a controller
running behind a UI. It refuses exactly three things, all sharing one
property - continuing makes a safety mechanism inoperative or makes a
stated limit untrue:

  1. max_w outside the setpoint device's own rating.
  2. No setpoint_entity: every write is a no-op, the device rating is
     never read, and the ESP32 heartbeat that holds off the layer-1
     failsafe never happens. It ran, looked healthy, and moved nothing.
  3. A meter_source that can never produce a reading. These were already
     caught, but they only DISABLED ingestion, which leaves grid None
     forever: permanent inputs-missing, 0 W, and a status page
     indistinguishable from a healthy meter nobody has fed yet.

Those last predicates move into p1.validate_meter_options(), which
build_source() also calls - one definition, two callers, not two
competing validators. ha_dsmr with half its entities and mqtt_p1 with a
blank topic gained the check the other two transports already had.

Deliberately not refused, because untidy is not unsafe: integrator_max_w
above max_w (the arbiter still bounds the wire to +-max_w, so the cost is
unwind latency - warned), a missing soc/batt entity (fail-safe and
already a red NOT READY banner), a setpoint entity that has not appeared
on the Core API yet (ESPHome is routinely late; re-checked in
run_control() once the real rating arrives), and a thin meter_poll_s
margin.

A refusal is legible as one: a banner saying in words that this is
configuration and nothing is broken, numbered problems, no traceback, and
exit 78 (EX_CONFIG).

Verified on the live add-on 2026-08-28, not by reading the code: a blank
setpoint_entity and a meter_poll_s equal to meter_max_age_s each stopped
the add-on with the banner and no stack trace.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 19:29:35 +02:00
glenn schrooyenandClaude Opus 5 0422127cab HANDOVER said 0.2.0; the running add-on is 0.4.0
Two versions stale. 0.3.0 shipped SAFETY-04 and TEL-01, 0.4.0 shipped TEL-04
and TEL-05 and changed the meter transport to homewizard_local - so a reader
taking this line at face value would look for a meter path that is no longer
how this system reads the grid.

Found in the 2026-08-27 backlog audit.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-27 23:55:37 +02:00
glenn schrooyenandClaude Opus 5 80ebb96e7d Two comments asserted an entity id that has never existed
mqtt.py said the P1 age entity "must be exactly sensor.p1_sample_age_s,
because SAFETY-01's firmware watchdog subscribes to that literal id", and
main.py:340 repeated it. Both are wrong, and wrong in the direction that
disarms a safety layer.

On HA 2026.8 object_id in a discovery payload does not determine entity_id.
HA composes it from the device name plus the entity name, so this one is
sensor.goodwe_p1_sample_age. That is what the firmware subscribes to, that is
what exists on the live system (verified 2026-08-26), and the firmware's own
comment records that sensor.p1_sample_age_s never existed on any HA.

The hazard is not the stale name itself, it is that two shipped artefacts
disagreed about a safety-critical id while sounding certain. A reader who
trusted these comments would have "corrected" the firmware to a name that
resolves to nothing - and the failure is silent, because has_state() simply
stays false forever and the ingest guard never arms. The firmware calls that
out as the shape that FAILS SILENTLY AND LOOKS CORRECT.

The comment now says what actually determines the id, and states plainly that
renaming the device or the entity's friendly name changes the composed id and
disarms the guard. It also cross-references TEL-06, since the guard reads this
sensor's value rather than its arrival and so cannot fire for a dead publisher.

Found in a backlog audit, as the substance behind PKG-02's premise: the real
coupling between firmware and add-on is names, not versions.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-27 23:48:40 +02:00
glenn schrooyenandClaude Opus 5 c70239cac2 0.4.0: the meter transports that fit this house
TEL-04 and TEL-05 merged without a version bump, so Home Assistant would not
have offered the update - the same trap DEPLOY-01 caught at 0.2.1, recurring
because merging a feature does not touch the version.

ha_signed reads one signed entity. homewizard_local polls the meter's own API,
where every HTTP response is a genuine arrival - the property the firmware
watchdog needs, and the one HA cannot provide for a repeated reading.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-26 01:31:54 +02:00
glenn schrooyenandClaude Opus 5 08f17f65dd TEL-05: read the meter, not Home Assistant's opinion of the meter
sensor.p1_sample_age_s measured time since the value CHANGED, not since the
meter REPORTED. Home Assistant fires no state_changed for a repeated reading and
exposes no arrival signal at all - proven on the rig three ways and confirmed
against the live house, where ten repeated meter values left last_reported
frozen every time. Real captured data in sim/scenarios/ has inter-change gaps of
42.2 s and 97.0 s, and the firmware watchdog thresholds that age at 30 s, so it
would have commanded 0 W on a perfectly healthy meter.

meter_source: homewizard_local polls GET /api/v1/data. Every HTTP response is a
genuine arrival. Same pipeline as ha_signed - only the arrival mechanism changed.

The decisive evidence is the STEADY case, not the frozen one: hwsim served a
literally constant 350.0 W for 70 s - the exact state where the HA path recorded
samples: 0 across 45 s - and this transport took 14 arrivals with the age never
exceeding the poll cadence. Reproduced independently by the reviewer against the
real hwsim, and again by the tester at 14/14.

179 -> 242 checks. Twelve mutants from the reviewer and six from the developer,
every one reddening a NAMED check rather than aborting the suite.

WHAT THIS DOES NOT DO. The ticket asked for two things that cannot both be true:
that the age reset on every HTTP response including an unchanged value, AND that
a frozen meter show a climbing age. A frozen meter still answers 200 OK - it IS
arriving - so no arrival detector can do both. That acceptance criterion was
wrong and was written by the PM; the developer refused it rather than quietly
building half of it.

Freeze detection is delivered separately as unchanged_s on the energy registers,
which the local API exposes and HA never did: 70.2 s frozen against 10.0 s
steady. Deliberately unthresholded, because at the converged -10 W this
controller aims for, a 1 Wh register needs about six minutes to move while the
power figure legitimately repeats - any threshold would rebuild the false-trip
cycle at the target operating point. It is surfaced on the status line so a
human can read it, which is what makes leaving it unthresholded defensible
rather than a dodge.

So the flash covers meter SILENCE, not meter DISHONESTY.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-25 21:27:13 +02:00
16 changed files with 3037 additions and 130 deletions
+33 -2
View File
@@ -12,7 +12,7 @@ a GoodWe GW5000S-BP.
| | |
|---|---|
| running | `local_goodwe_controller` **0.2.0**, `boot: auto`, holding grid at zero |
| running | `local_goodwe_controller` **0.4.0**, `boot: auto`, holding grid at zero |
| installed as | a **Local** add-on: `/addons/goodwe_controller` on HA OS at 192.168.2.158 |
| repo | Gitea `admin/goodwe-addon` (ssh://git@192.168.2.147:2222) — **private** |
| tuning | gain 0.6, `max_w` 5000, slew 1000, deadband 15, step 10, saturation 500/3, heartbeat 10 s |
@@ -52,9 +52,40 @@ Run the checks before deploying. No framework needed:
```bash
cd goodwe_controller
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py \
&& python3 test_validate.py && python3 test_p1.py && python3 test_watchdog.py \
&& python3 test_loop.py
```
`test_watchdog.py` covers SAFETY-02's logic, its arming gate (derived from the
real arbiter, not passed in), its trip path, and the fact that the latch survives
an add-on restart. Its headline validation is not here at all: `sim/replay_sign.py`
in the infra repo drives the same module over the two captured RS485 days and must
fire on all four of the 2026-08-20 episodes and stay silent on 2026-08-23. That
needs both checkouts:
```bash
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py --stub
```
The second run checks the grader still *discriminates* rather than merely still
passing — a watchdog that never trips and one that always trips must both be
rejected.
⚠️ **If you are testing the failsafe by hand, note that stopping and starting the
add-on will not clear a trip.** That is the point of it; use the *Start / stop
control* button twice, or delete `sign_tripped` from `/data/state.json`.
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
wall-clock property about it (SAFETY-12); mocking the clock there would leave the
assertion testing the mock. The other six suites together are ~440 checks and finish in
seconds — `test_watchdog.py` spends ~3 s of that driving a real `Controller` through a
trip. If you shorten `test_loop.py`'s windows, re-measure and correct this figure —
an understated runtime is what makes a slow test look like a hung one, and a slow test
that looks hung gets deleted.
---
## 3. Known broken / unfinished
+408
View File
@@ -2,6 +2,414 @@
## Unreleased
**Cheap-window maintenance charging was unreachable at the shipped defaults, and
now the config that makes it unreachable is refused (MAINT-04).** `config.yaml`
shipped `max_w: 2000` against `maintenance_charge_w: 2500`. The cheap-window
shaping files `Claim.limit(hi = -maintenance_charge_w)` against the supervised
SAFETY limit's `lo = -max_w`, so `lo > hi` — the arbiter's clause 3, correctly
resolved to **0 W** and logged as a CONTRADICTION. **Maintenance silently never
charged in a cheap window on a default install**, and the only evidence read
like a bug in the arbiter rather than like the two numbers an operator set.
Measured against the real arbiter, loop asking +500 W:
```
max_w=2000 hi=-2500 -> +0 W contradiction=True
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(cheap-window charge)
```
`validate_startup_config()` now refuses `maintenance_charge_w > max_w` (rule 6),
the same shape as CFG-01's `sign_disagree_w >= max_w`: a number the operator set,
overridden by a layer they cannot see. Equality is reachable (`-max_w` is a
single valid point) and deliberately not refused. Verified by starting the
add-on on the pre-fix pair: exit 78, the refusal banner, no traceback.
**`maintenance_discharge_w` was checked, not assumed, and it is NOT the same
case.** The shaping is not symmetric. The drain phase does not shape the loop,
it OWNS the actuator — `Claim.set(P_MAINTENANCE, +discharge_w)` — and a SET is
*clamped* by the limits above it rather than contradicted by them. 2500 against
a 2000 W ceiling emits **+2000 W**, and the arbiter's own `explain()` prints
`maintenance -> 2000 W, limited by supervised(max_w)` every cycle. Nothing is
silent and energy still moves; the cycle completes slower (13.8 kWh usable at
2000 W is ~6.9 h against the 720 min drain timeout). **Warned about, not
refused.**
**The shipped defaults changed so the validator does not reject them.**
`maintenance_charge_w` and `maintenance_discharge_w` are now **2000**, at the
shipped `max_w`. `max_w` was deliberately NOT raised instead: it is the
supervised safety ceiling and raising a default upward ships more power to every
new install. Raising `max_w` (the reference install runs 5000) is what unlocks a
faster maintenance cycle — raise it first, then these. `test_validate.py` now
reads `config.yaml` itself and asserts the shipped numbers pass the rule, so a
default that the validator refuses cannot ship again.
### ⚠️ Upgrading an existing default install: the add-on may refuse to start
An install still carrying `maintenance_charge_w: 2500` against `max_w: 2000`
now meets rule 6 and **exits 78 with the refusal banner** instead of starting.
That is the intended behaviour — the configuration was already broken, it was
just silent about it — but an add-on that will not come back after an update
needs the fix stated here rather than only in the log.
**The fix, either way: set `maintenance_charge_w` to `2000` or lower, OR raise
`max_w` to `2500` or higher** (Settings → Add-ons → GoodWe RS485 Controller →
Configuration), then start it. The banner in the log says the same thing and
names both numbers.
Whether you hit this at all depends on whether the Supervisor kept the old
value, and **both cases are covered above because we did not verify which one
applies here.** The Supervisor merges an add-on's *stored* options over the
defaults in `config.yaml`, so:
- **A key the operator never edited** re-derives from the new `config.yaml` and
becomes 2000 on upgrade. Non-event, nothing to do.
- **A key the operator did set** persists at 2500 and the add-on refuses to
start until it is changed. Note this includes anyone who used the
Configuration page's YAML editor, which writes the whole options block back —
so "I never touched that field" is not a guarantee the old value is gone.
⚠️ **This is reasoned from the Supervisor's documented merge behaviour, not
measured on the live install.** The reference install's stored options could not
be read (`/api/hassio/` refuses a long-lived token) and probing it was out of
scope — it regulates a real battery. It runs `max_w: 5000` and is unaffected
either way.
⚠️ **Known, deliberately left, and worth a follow-up:** `main.py` and
`maintenance.py` still fall back to **2500** when the key is absent from the
options dict, while `config.yaml` and `validate.py` now say 2000. Unreachable on
a Supervisor install (every key is always supplied) and reachable only from
tests/`sim`. The real fix is one source of truth for option defaults, which is
bigger than this ticket and touches files another ticket is in.
## 0.5.1
**SAFETY-02's latch now survives an add-on restart, which is the difference
between a latch and a pause.** `auto` was persisted and `sign_wd.tripped` was
not, so reconstructing the `Controller` against the same store — exactly what a
container restart does — brought it back **armed, into the same fault, with no
operator involved**: `tripped=False`, banner back to `NOT READY`, and it resumed
commanding (measured: −1000 W, −2000 W) before re-tripping 180 s later. Under a
Supervisor that restarts a crashed add-on that is a loop of three-minute
wrong-direction bursts — and "restart the add-on" is the first thing an operator
looking at a `FAILSAFE` banner and a 0 W inverter will try.
`sign_tripped` and `sign_reason` are now `Store` keys beside the maintenance
state, written the moment the trip happens (reason first, flag second, so a crash
between the two can never persist a latch with no explanation) and restored in
`Controller.__init__`. Cleared only by the operator's start. `DOCS.md` said "it
does not clear itself"; that was false across a restart and now is not.
Also in this release, all of it review follow-up rather than new behaviour:
- **The arming gate is tested against the real arbiter.** It was the decision the
whole ticket turns on and it was asserted in three comment blocks and verified
by nothing — every case passed `following` in as a literal. `test_watchdog.py`
now derives it from `resolve()` across twelve claim configurations, including
the redirect case `winner == "loop"` alone would have got wrong and the `lo`
limit that raises magnitude without flipping sign.
- **The MQTT `status: "failsafe"` value is tested.** The check that claimed to
cover it restated the assertion three lines above it and never touched the
payload.
- **A forward hazard written down where it will be read, and made to bite.**
`winner == "loop"` disarms the watchdog under any higher-priority SET claim.
Today only maintenance and the safety stops emit one and neither follows the
meter; a peak-shaving strategy at `P_PEAK` **does**, and would blind the
watchdog for every peak event.
The gate is now `watchdog.loop_is_following()`, called by both `main.py` and
the test, for the same reason `disagrees()` was extracted: the test held a
*transcription* of the shipped expression, so editing the shipped gate alone to
`winner in ("loop", "peak")` left every suite green while the watchdog went
blind. Two copies, and the one that drifts is the one doing the grading.
⚠️ Extracting it was not sufficient on its own. The realistic P_PEAK row —
peak shaving asking for *more* than the loop — still could not detect the
widened gate, because the magnitude term rejects it regardless and masks the
winner term. A second row with peak asking for *less* isolates `winner` as the
only deciding term, and that is the one that turns red.
- **The worked example described a configuration that does not ship.** At the
defaults `maintenance_charge_w` (2500) exceeds `max_w` (2000), so that claim is
an arbiter *contradiction* resolving to 0 W, not a −2500 W charge. The example
is now written at 1500 W. (The contradiction is a real pre-existing bug —
a default cheap-window maintenance charge silently never happens — filed
separately, deliberately not fixed here.)
- **`disagrees()` is public**, so `sim/replay_sign.py` stops carrying its own copy
of the predicate it grades.
- `held_s` takes the clock instead of reading one, restoring the pure-function
property the module advertises.
- **The `sign_reason`-before-`sign_tripped` write ordering is enforced, not just
documented.** Swapping the two lines used to pass every check. A store that
fails the second write now proves the property the ordering exists for: what
survives a crash mid-trip is a reason with no latch, never a latch with no
explanation.
- Measured figures corrected throughout: 93.4 % / 4212 of 17280 (was 92.9 % /
4127 of 16349), per-cluster 0.3 / 0.9 / 10.5 / 0.0 %.
## 0.5.0
**SAFETY-02 — the sign-disagreement watchdog.** The add-on now watches whether
the setpoint it is emitting and the grid figure it is regulating on point the
same way. If they oppose each other, both over `sign_disagree_w` (300 W), for
`sign_disagree_s` (180 s) **continuously**, it files a failsafe claim at
`P_SAFETY`, commands **0 W**, and latches there until an operator starts control
again. New module `app/watchdog.py`; new options `sign_disagree_w` and
`sign_disagree_s`.
This is the gap the existing failsafes leave open. The stale-input watchdog asks
whether the meter is still talking, the saturation freeze asks whether the
inverter can follow, the output clamp asks whether the number is too big — a
loop can pass all three while charging the battery out of the grid, because the
only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly
that four times in one day, for up to 77 minutes at a stretch, and reached a
commanded −14 768 W against a ±5000 W inverter.
Validated against that day. `sim/replay_sign.py` in the infra repo drives this
module over the committed RS485 captures of both 2026-08-20 (the four episodes)
and 2026-08-23 (healthy): **18 trips on the fault day, every one inside a window
`NOTES.md` §4.7 accounts for, and 0 on the healthy day.** The four episodes do
share one signature rather than merely resembling each other — sign agreement
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 93.4 % on the healthy day.
Three decisions worth knowing about:
- **It is disarmed whenever the grid-following loop is not what is driving.**
Sign agreement is a property of a loop that follows the meter. A maintenance
grid charge opposes the meter *by design* — 2500 W of charge into a house
drawing 500 W is +3000 W on the meter against a −2500 W command, for hours —
and armed unconditionally this would trip on every maintenance cycle. The gate
tests the emitted number, not the winning claim's name: a limit claim can let
the loop "win" and still replace its value with one pointing the other way.
- **The trip latches.** Commanding 0 W removes the command side of the
comparison, so the disagreement always clears the moment the trip works.
Un-latched, this would trip, clear, and hand the actuator back to the loop that
was driving the wrong way, every three minutes forever.
- **`sign_disagree_w` at or above `max_w` is refused at startup** (validator rule
5). The arbiter never lets a command exceed `max_w`, so such a threshold makes
the watchdog incapable of firing while the status page still reports it armed.
A disarmed guard that advertises itself as armed is the failure mode this
project keeps refusing to ship.
What it does **not** catch, stated so nobody assumes otherwise: an inverter that
acts opposite to what it was told moves the meter *further* the same way, so
command and meter agree while everything runs away. That is the saturation
freeze's job, which compares the command against the battery's actual power.
`test_validate.py`'s "the smallest sane max_w still starts" case now names a
reachable sign threshold, because a 1 W ceiling genuinely does disarm the 300 W
default and is now correctly refused.
## 0.4.0
**CFG-01.** The add-on now refuses to start on a configuration it cannot honour,
instead of logging a line and carrying on. `validate_startup_config()` runs in
`amain()` before the broker, the web server or any task exists, so a refusal
cannot leave half a controller running behind a UI.
It refuses only where continuing produces one of two outcomes: **(a)** a stated
limit is untrue - the operator configured a bound and a lower layer silently
enforces a different one - or **(b)** the add-on is inert and indistinguishable
from healthy. (b) is not a special case of (a): with no `setpoint_entity`, layer
1 pinning the inverter at 0 W is the failsafe *working*. The system does not
become unsafe, it becomes a convincing impression of a working controller.
Four things qualify:
- **`max_w` above (or below) the setpoint device's own rating.** This is the one
that changed behaviour. It used to warn `the device wins` and run anyway, with
`write_setpoint()` silently clamping, so the configured ceiling was never the
real one and the only evidence had scrolled off the log. The refusal names the
configured value, the device's value, and which wins.
- **No `setpoint_entity`.** A controller with no actuator: every write is a
no-op, the device rating is never read, and the ESP32 heartbeat that holds off
the layer-1 failsafe never happens. It ran, looked healthy, and moved nothing.
- **A `meter_source` that can never produce a reading** - missing `p1_host`,
missing `p1_net_entity`, a blank MQTT topic, a phase list disagreeing with
`meter_phases`, an unknown source name, or a `meter_poll_s` at or past
`meter_max_age_s`. These were already caught, but they only *disabled
ingestion*, which leaves the grid reading None forever: permanent "inputs
missing", 0 W, and a status page indistinguishable from a healthy meter nobody
has sent anything to yet.
- **`meter_max_age_s` above the firmware's ingest veto.** The schema accepts
`int(5,300)`; the ESP32's threshold is a compile-time `max_age_s: "30"` and it
trips layer 1 at `p1_age_s >= 30`. Set 120 and the add-on treats a 119 s
reading as fresh and keeps commanding, while the firmware has already vetoed
and is holding the inverter at 0 W - healthy meter, running controller,
nothing moving, and no line anywhere saying the number you set was overruled.
Structurally the same fault as the `max_w` case. Only *above* the veto is
refused: below it the add-on gives up first, which is fail-safe and visible on
its own status page. Mirrored as `validate.FIRMWARE_INGEST_VETO_S` - it cannot
be imported from a compile-time YAML substitution, so it carries a note about
the one direction in which it can go stale.
`max_w` at or below zero is refused too. Schema-blocked on a real install, but
`validate_startup_config()` is now also the simulation suite's entry point, and
a non-positive `max_w` inverts the arbiter's `supervised` bounds into a
contradiction that resolves to 0 W - i.e. it would read as a safety trip rather
than as the typo it is.
The predicates for the meter group still live in `p1.validate_meter_options()`,
which `build_source()` also calls - one definition, two callers, not two
competing validators. Two transports gained a check they never had: `ha_dsmr`
with only one of its two entities, and `mqtt_p1` with a blank topic, both of
which previously built a transport that could never read.
Deliberately **not** refused, because it is untidy rather than unsafe:
`integrator_max_w` above `max_w` (the arbiter still bounds the wire to ±max_w,
so the cost is unwind latency, not amperage - warned), a missing `soc_entity` /
`batt_entity` (fail-safe, and already a red NOT READY banner naming it), a
`setpoint_entity` that has not appeared on the Core API yet (ESPHome is routinely
late; refusing would make a slow boot need a human - re-checked once the real
rating arrives), and a thin-but-nonzero `meter_poll_s` margin.
A refusal is legible as a refusal: a banner that says in words that this is a
configuration problem and nothing is broken, the numbered problems, no traceback,
and exit status 78 (`EX_CONFIG`).
**SAFETY-12.** The control loop now evaluates on a clock as well as on a change.
`run_control()` ran `cycle()` only when the meter value differed from the
previous poll, so a meter that repeated a value ran **no control cycles at
all** - while the heartbeat went on re-emitting the last command and the
firmware went on putting it on the wire every 2 s. Layer 1 stayed fed, every
indicator read healthy, and a command computed from an old reading kept being
executed through whatever the load did next. Measured on the rig during TEL-05:
70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
**It was worse than a latency limit: it was a safety claim that could not
fire.** `stale_input_s` and the `inputs missing -> 0 W` claim both live *inside*
`cycle()`. Pre-fix, if the meter value happened to be constant, `cycle()` was
never called again - so that claim had no way to run. Constant meter, SoC entity
dying at t=4 s, same binary:
```
pre-fix writes: [(0.0, 220.0), (0.0, 220.0), (10.1, 220.0)]
final target: 220.0 W reason: 'loop -> 220 W'
post-fix writes: [(0.0, 220.0), (0.0, 220.0), (3.0, 430.0), (9.1, 0.0), (10.1, 0.0)]
final target: 0.0 W reason: 'safety -> 0 W'
```
The pre-fix controller held 220 W through the entire input outage with its
status line still reading `loop -> 220 W`, and layer 1 does not cover that case
on a `meter_source: off` install: no P1 age sensor is published, so the firmware
has nothing to veto on, while the heartbeat keeps its watchdog fed. So the old
behaviour was not "holds a stale command safely" - it was a failsafe that a
repeating meter switched off. `test_loop.py` asserts both halves.
`cycle_floor_s` (default **15 s**) is a deadline on the gap between cycles, not
a second scheduler: every cycle resets it, whichever trigger fired. On a healthy
meter it never elapses, so the cycle rate, the write sequence and therefore the
per-cycle gain the tuning was measured against are unchanged - asserted in
`test_loop.py` by driving the real loop twice on one binary (a huge
`cycle_floor_s` reproduces the old behaviour exactly) and comparing the
commanded values.
The reset is not the only thing holding that up, and the other argument is the
sturdier one: the combined cycle rate is `max(arrival rate, 1/floor)`, never the
sum. At 1/15 s the floor is strictly slower than the ~1/5 s arrival rate, so
even a hypothetical floor racing the arrivals could not exceed the nominal
healthy rate. The re-tune is unreachable by construction. ⚠️ That holds only
while `cycle_floor_s` stays above the meter's update interval, and the schema
minimum is 5 s - which is exactly the reference meter's interval. Nothing
enforces the relationship; `validate.py` is the obvious home for it and does not
have it yet.
Observed over six real minutes on the same rig, one binary, meter held at a
literally constant 350.0 W: **before, 1 cycle** (at startup) and then nothing,
the command stuck at 220 W against a 350 W import for the rest of the window.
**After, 24 cycles**, worst gap 15.14 s, and the ordinary PI ramp doing its job -
220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle,
rail at t=136 s and flat after. Three minutes with the meter parked at the
target instead: **1 cycle before, 12 after, and 19 writes either way - the same
19**. Three minutes on a normally-changing meter: **36 cycles and 49 writes on
both sides, the same values in the same order.** The heartbeat write count never
moves; the only writes the fix adds are the ten the loop was supposed to be
making all along.
15 s is bracketed, not round.
**Below it, ~11 s, and it arises more routinely than a dropped poll.**
`HomeWizardLocalSource` polls at 5.0 s against a meter that updates every 4.97 s
(NOTES.md:640). Two near-equal periods beat, so roughly once every ~14 minutes
the poller steps over an update entirely - a ~10 s gap between changed values on
a perfectly healthy meter, plus up to 1 s for the 1 s tick to notice. A failed
HTTP poll (retried on the next tick, no backoff) adds another 5 s. The floor
sits above the beat-skip so it does not fire on that alone; what it takes to
reach 15 s is a beat-skip *and* a failed poll coinciding.
**Above it, 30 s.** `meter_max_age_s` is 30 s, past which there is no reading to
evaluate, and the firmware's ingest veto is also 30 s - so the loop is
guaranteed to have re-decided at least twice inside any window in which layer 1
might otherwise be the only thing deciding. ⚠️ The default is therefore not
independently justified at 15: if the firmware's veto ever moves, this moves
with it. Noted beside the constant in `main.py`.
It is also exactly `stale_input_s`, this system's existing answer to "how long
may we hold without re-deciding".
A floor cycle runs the **full** law on the same inputs, integrator included. In
P1 mode the freshness question is already answered upstream and answered harder
- past `meter_max_age_s` the reading is None, which is "inputs missing", which
is a `P_SAFETY` 0 W claim - so a floor cycle there can only ever run on a reading
this system already calls fresh. ⚠️ That is transport-conditional: with
`meter_source: off`, `read_inputs()` takes the grid figure straight from
`hass.number()` with **no age gate at all**, so a Home Assistant entity that has
gone quiet reads as current on that path, with or without this change. Running
the full law is still right there - the alternative is a degraded second law
reasoning about an age nobody measured - but the floor does not make that path
fresh. The integrator advances per *cycle*, not per second,
so bounding the gap bounds the accumulation; `integrator_max_w` bounds it after
that. A gentler second law for floor cycles would be a second set of dynamics
nobody can test on this hardware.
⚠️ **This is not a freeze detector**, and TEL-05 established one cannot be built
here: at the converged -10 W target a 1 Wh register needs ~6 minutes to move
while the power figure legitimately repeats, so any threshold on `unchanged_s`
false-trips at the exact operating point we run at. Nothing in this change
decides whether a repeated reading is *true*. It stops "the number is the same"
from meaning "do not think". The consequence, stated plainly: against a meter
genuinely frozen at a wrong value the loop will now correct toward that wrong
value rather than hold a stale command, bounded by `max_w`, the arbiter and the
device rating. That was already what happened to a lying meter whose value
merely jittered; bit-exact repetition was never a safety property.
`DOCS.md`'s "Saturation is counted in cycles, not seconds" section documented
the old behaviour as an accepted deviation. It is **qualified, not deleted**:
the deviation survives (the window is still counted in cycles, and 3 x 15 s is
still not the specification's 10 s) but it is now bounded at 45 s instead of
open-ended, and the passage's second justification - "nothing accumulates while
it is stalled" - is called out as having covered integrator windup and not
staleness, which was the actual hazard. The same wrong argument in
`control.py`'s saturation comment is corrected too.
**TEL-04.** `meter_source: ha_signed` reads a single *signed* power entity, which
is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two
unsigned registers and refuse negatives, so neither fits the meter installed here.
**TEL-05.** `meter_source: homewizard_local` polls the meter's own local API
directly. This exists because of something the HA paths cannot do: Home Assistant
fires no state change for a repeated reading and exposes no arrival signal at
all, so `sensor.p1_sample_age_s` on those transports measures time since the
*value changed*, not since the meter *reported*. Real captured data has gaps of
42 s and 97 s between changes on a perfectly healthy meter - long enough for a
30 s staleness threshold to command 0 W for no reason. Every HTTP response to the
local API is a genuine arrival, so the age means what it says.
Verified on the rig against a literally constant 350.0 W for 70 s - the exact
state where the HA path recorded zero samples in 45 s - with 14 arrivals and the
age never exceeding the poll cadence.
Set `p1_host` to the meter's address and `meter_poll_s` (default 5 s, matching
the meter's own ~5 s update). Still defaults to `off`; nothing changes for an
install that does not opt in.
Freeze detection is separate and deliberately not thresholded: a meter answering
200 OK with a stale number *is* arriving, so no arrival stamp can flag it. The
energy registers carry that as `unchanged_s`, surfaced on the status line for a
human to read rather than alarmed on - at a converged -10 W a 1 Wh register needs
about six minutes to move, so any threshold would false-trip at the target
operating point.
## Unreleased
**TEL-05.** A fourth `meter_source`, `homewizard_local`, which polls a
HomeWizard P1's **own local API** (`GET /api/v1/data`) instead of watching a
Home Assistant entity. Set `p1_host` to the meter's address; `meter_poll_s`
+98 -16
View File
@@ -24,6 +24,9 @@ The inverter **holds its last command forever** — it has no meter-timeout. So:
commanding it.
- This add-on commands 0 W when its inputs go missing, when you stop control,
and when it shuts down.
- This add-on commands 0 W **and latches there** if what it is commanding and
what the meter reads point opposite ways for three minutes — see "The
sign-disagreement failsafe" below.
- The **optional RS485 e-stop** is the only thing that covers this machine
dying. Without it, a failed host leaves the battery latched at its last
command until someone intervenes.
@@ -272,11 +275,69 @@ behind it would trip the firmware watchdog on a system that is working fine.
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
| `step_w` | 10 | Quantisation |
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one meter update or `cycle_floor_s`, whichever comes first - see the note below. **Do not set to 1** |
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
| `cycle_floor_s` | 15 | The longest the loop may go without evaluating. A deadline on the gap between cycles, reset by every cycle — on a healthy meter it never elapses and changes nothing. Raise it only if your meter is slower than ~10 s; it must stay under `meter_max_age_s`, past which there is no reading to evaluate anyway |
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
| `auto_start` | false | Start controlling on boot (only after commissioning) |
| `sign_disagree_w` | 300 | Both the command and the meter must exceed this before a sign difference counts. Must stay **below `max_w`** or the watchdog can never fire, and the add-on refuses to start |
| `sign_disagree_s` | 180 | How long they must stay opposed, continuously, before the failsafe trips |
#### The sign-disagreement failsafe
If the setpoint this add-on is emitting and the grid figure it is regulating on
point **opposite ways** — charging the battery while the house imports, or
discharging it while the house exports — with both over `sign_disagree_w`, for
`sign_disagree_s` **continuously**, the add-on commands **0 W** and holds it
there. The banner reads `FAILSAFE`, the commissioning list says which two
numbers disagreed and for how long, and the `Controller status` entity reports
`failsafe`.
**It does not clear itself, and restarting the add-on does not clear it either.**
Pressing *Start / stop control* twice — stop, then start — is the only thing that
does. That is deliberate on both counts:
- Commanding 0 W removes the command side of the comparison, so the disagreement
always vanishes the instant the trip works. A watchdog that took that as proof
the fault was over would hand the inverter straight back to the loop that was
driving the wrong way, three minutes later, forever.
- The trip is written to `/data/state.json` and restored on startup. Restarting
the add-on is the first thing most people try when they see a red banner, and
a latch that a restart clears would bring the controller back **armed, into the
same fault, unattended** — and under a Supervisor that restarts a crashed add-on
automatically, would do so in a loop. After a restart the banner, the 0 W and
the recorded reason are all still there.
**What it is for.** This is a loop-integrity check: it asks whether the loop's
output direction still matches the input state it was regulating. It catches a
polarity error anywhere between the meter and the wire, and an integrator so far
wound up that unwinding takes minutes. It is the check that would have caught all
four episodes of 2026-08-20, when a commercial controller charged the battery out
of the grid, four times, for up to 77 minutes at a time.
**What it is not for.** It does not detect an inverter that acts opposite to what
it was told — that moves the meter *further* the same way, so command and meter
agree while everything runs away. That is the saturation freeze's job
(`saturation_w` / `saturation_cycles`), which compares the command against the
battery's actual power. The two checks are complementary and neither replaces the
other.
**Why it will not false-trip on ordinary operation.** A battery that refuses a
command (empty, full, standby) leaves the meter where it was, so command and
meter agree. A frozen meter drives the loop into agreeing with it. Around the
resting point both signals are inside the 300 W gate, so the deadband can never
produce one. A load step does flip the meter's sign before the loop catches up —
measured on a full captured day, the longest such crossing is 30 s, against a
180 s window. And the watchdog is **disarmed whenever the grid-following loop is
not what is driving**: a maintenance grid charge opposes the meter by design and
must not be mistaken for a fault.
Both numbers are measured rather than chosen, and are exposed only because the
ticket requires defaults rather than constants. On the captured healthy day sign
agreement is 93.4 %; on the four captured fault clusters it is 0.3 %, 0.9 %,
10.5 % and 0.0 %. There is no reason to move either value without a capture that
says so.
#### Saturation is counted in cycles, not seconds
@@ -284,22 +345,43 @@ The specification states the saturation window as **"> 10 s"**. This add-on coun
**cycles** instead, and that is a deliberate, accepted deviation rather than an
oversight - the acceptance criterion is not met as literally written.
A cycle here is one *changed* meter reading: the controller only runs the loop when the
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
window** - a meter that repeats the same value stalls the counter for as long as it
repeats.
A cycle here is one meter update **or `cycle_floor_s` elapsing, whichever comes
first**. At the reference P1's ~5 s update rate the default of 3 cycles is usually
around 15 s, and the worst case is bounded at `3 x cycle_floor_s` = 45 s. It is still
not the 10 s the specification asks for, so the deviation stands - but it is now a
bounded number rather than an open one.
Two reasons that is acceptable:
⚠️ **This passage used to say something different, and the second half of it was
wrong.** Until SAFETY-12 the loop ran only when the meter value *changed*, so a meter
that repeated a value stalled the counter for as long as it repeated, with no upper
bound at all. That was defended here on the grounds that "a stalled counter is a
detection-latency limit and not a runaway risk - the condition that stalls it stops the
whole loop, so nothing accumulates while it is stalled". That argument covers
**integrator windup and nothing else**. The hazard it misses is **staleness**: while the
loop was stopped the heartbeat kept re-emitting the last command and the firmware kept
putting it on the wire every 2 s, so a command computed from an old reading went on
being executed through a real load change, with every indicator reading healthy.
Measured on the rig during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals,
zero control cycles.
- the control law is a pure function with no clock, which is what makes it testable
without hardware, and a seconds-based window would have to live in the controller;
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
while it is stalled.
The half that survives is the first one: the control law is still a pure function with
no clock, and the wall-clock window still lives in `Controller`, which has one - see
`run_control()`. What changed is that the controller now enforces a floor on the gap
between cycles, so `saturation_cycles` finally means a bounded number of seconds.
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
and treat the figure as "N meter updates" rather than "N seconds".
If a tighter window matters on your site, lower `cycle_floor_s` (not below your meter's
update interval, or the floor starts firing on a healthy meter) or raise
`saturation_cycles` for a fast meter.
**This is not a freeze detector, and it deliberately cannot be one.** Nothing here
decides whether a repeated reading is true — see `unchanged_s` in the meter section for
why no threshold on that is safe at the converged operating point. The floor only stops
"the number is the same" from meaning "do not think". The consequence is worth stating
plainly: against a meter that is genuinely frozen at a wrong value, the loop will now
correct toward that wrong value instead of holding a stale command. It is bounded by
`max_w`, the arbiter and the device rating, and it is the same thing that already
happened to a lying meter whose value merely jittered — bit-exact repetition was never a
safety property.
#### Why `target_grid_w` is not zero
@@ -332,8 +414,8 @@ help - see "Why the tuning is what it is".
| `maintenance_enabled` | false | Enable the monthly cycle |
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
| `maintenance_discharge_w` | 2500 | Drain rate (exports the surplus) |
| `maintenance_charge_w` | 2500 | Charge ceiling, capped again by peak headroom |
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor |
| `maintenance_soc_target` | 99 | Charge target |
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
+16 -12
View File
@@ -95,19 +95,23 @@ def compute(
# lets slew be larger than saturation_w.
#
# The spec states this window twice and differently: "> 10 s" (§11.2) and
# "3 samples" (§10.3). This counts CYCLES, and a cycle is not a unit of
# time: run_control() calls cycle() only when the meter value CHANGES
# (`if self.grid != last_grid`), so three cycles is three distinct meter
# readings and nothing more. At the reference P1's ~5 s update rate that is
# usually ~15 s, but there is no upper bound on it - a meter that repeats a
# value stalls the counter.
# "3 samples" (§10.3). This counts CYCLES, and a cycle is still not a unit
# of time - but it is now a BOUNDED one. run_control() runs a cycle on a
# changed meter value OR on `cycle_floor_s` elapsing, whichever comes first
# (SAFETY-12), so three cycles is at most 3 x cycle_floor_s = 45 s at the
# defaults, and usually ~15 s at the reference P1's ~5 s update rate.
#
# That is a detection-latency limit, not a windup hazard: the same
# condition that stalls the counter stalls the whole loop, so nothing
# accumulates in the meantime either. If a wall-clock window is ever
# required, it belongs in Controller (which has a clock) and not here.
# ponytail: this function is worth keeping clockless; the ceiling is that
# saturation_cycles cannot express a guaranteed number of seconds.
# ⚠️ THIS COMMENT USED TO CLAIM there was no upper bound and that it did not
# matter, "because the same condition that stalls the counter stalls the
# whole loop, so nothing accumulates in the meantime". The first clause was
# true and the second was the bug: a stalled loop does not stop commanding,
# it goes on emitting its last command through the heartbeat. Windup was
# never the hazard; staleness was.
#
# The wall-clock window lives in Controller, which has a clock, exactly as
# this comment always said it should. ponytail: this function stays
# clockless; the remaining ceiling is that saturation_cycles expresses a
# bound in seconds rather than an exact number of them.
saturated_now = abs(prev_w - actual_w) > tuning.saturation_w
sat_count = min(sat_count + 1, 10) if saturated_now else 0
frozen = sat_count >= tuning.saturation_cycles
+272 -13
View File
@@ -40,6 +40,8 @@ from .hass import HomeAssistant
from .maintenance import IDLE, MaintConfig, Maintenance
from .mqtt import MqttPublisher
from .p1 import P1Ingest, build_source, is_enabled
from .validate import ConfigRefused, refuse, validate_startup_config
from .watchdog import SignWatchdog, SignWatchdogConfig, loop_is_following
from . import web
OPTIONS_PATH = "/data/options.json"
@@ -56,11 +58,22 @@ def load_options() -> dict:
class Controller:
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub):
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub, *, stop):
self.o = opts
self.hass = hass
self.store = store
self.mqtt = mqtt_pub
# ⚠️ REQUIRED, AND KEYWORD-ONLY, AFTER A REVIEW CATCH. This started life
# as `stop=None`, which made a Controller that CANNOT STOP ITSELF the
# default one. On the late-refusal path in run_control() that default
# meant: log the banner, return, and leave the process alive forever
# with no control loop, no exit and no further output - the exact
# "inert but looks healthy" failure this whole module exists to refuse.
# amain() always passed a real Event, so it was latent, but test_p1.py
# was already constructing Controllers without one. No default now, so
# the broken shape does not typecheck.
self.stop_event = stop
self.refused: list[str] | None = None
self.tuning = Tuning(
gain=float(opts.get("gain", 0.6)),
@@ -91,6 +104,29 @@ class Controller:
store,
)
# SAFETY-02. One instance, one actuator, one cadence - see watchdog.py.
#
# ⚠️ RESTORED FROM THE STORE, and that is the difference between a latch
# and a pause. A trip held only in memory is cleared by the one action an
# operator staring at a FAILSAFE banner is most likely to take - restart
# the add-on - and the controller then comes back armed, into the fault,
# with nobody involved. Restored here, the banner and the 0 W survive the
# restart and only `auto_toggle` clears them.
self.sign_wd = SignWatchdog(
SignWatchdogConfig(
min_w=float(opts.get("sign_disagree_w", 300)),
hold_s=float(opts.get("sign_disagree_s", 180)),
),
tripped=bool(store.data.get("sign_tripped", False)),
reason=str(store.data.get("sign_reason", "") or ""),
)
if self.sign_wd.tripped:
_LOG.error("SAFETY-02 was TRIPPED before this restart and stays "
"tripped: %s. The inverter is held at 0 W. Restarting the "
"add-on does not clear this - start control from the UI "
"once you know why the command opposed the meter.",
self.sign_wd.reason or "(reason not recorded)")
# P1 ingestion (TEL-01). `meter_source: off` keeps the original
# single-entity meter_entity path, so an existing install is unchanged
# until it opts in.
@@ -108,6 +144,11 @@ class Controller:
self.sat_count = 0
self.i_w = 0.0 # the loop's integrator, carried between cycles
self.loop_w = None # what the loop asked for last cycle, or None
# Did the grid-following loop actually win the LAST arbitration? That is
# the question SAFETY-02 has to ask about the command standing on the
# wire right now, so it is recorded when the arbitration happens rather
# than re-derived a cycle later. Starts False: nothing is on the wire.
self.following = False
self.reason = "starting"
self.grid = self.soc = self.batt = None
self.peak_fc = None
@@ -202,8 +243,38 @@ class Controller:
for msg in result.events:
self.log_event(msg)
# --- SAFETY-02, and it runs BEFORE the early return below -------------
# ⚠️ ORDER MATTERS HERE. If this were evaluated after the "inputs missing
# but not yet stale" hold, a run of held cycles would leave
# `disagree_since` untouched across the gap and the timer would resume
# from a start time that predates it. It is evaluated every cycle,
# unconditionally, so a missing meter CLEARS the window - see watchdog.py.
#
# The value compared is the command STANDING ON THE WIRE, which is what
# this cycle's fresh meter reading is a response to. `last_write` is that
# value after the device clamp and confirmed accepted; `target` covers
# the case where nothing has been written yet (and, deliberately, the
# case where the last write was REJECTED - the inverter is then still
# latched on `last_write`, which is exactly what `last_write` holds).
was_tripped = self.sign_wd.tripped
standing = self.last_write if self.last_write is not None else self.target
if self.sign_wd.evaluate(standing, self.grid, self.following, now) \
and not was_tripped:
# ⚠️ REASON FIRST, FLAG SECOND, and each `set` writes the file. The
# ordering is the whole atomicity story: a crash between the two
# persists a reason nothing reads, which is harmless, where the other
# order persists a latch with no explanation for the operator who has
# to decide whether to clear it.
self.store.set("sign_reason", self.sign_wd.reason)
self.store.set("sign_tripped", True)
self.log_event("FAILSAFE " + self.sign_wd.reason)
_LOG.error("SAFETY-02 TRIPPED - %s. Commanding 0 W and holding it "
"until control is started again. This survives an add-on "
"restart; restarting will not clear it.",
self.sign_wd.reason)
stale_after = float(self.o.get("stale_input_s", 15))
if not self.inputs_ok:
if not self.inputs_ok and not self.sign_wd.tripped:
bad_for = (now - self.inputs_bad_since).total_seconds() if self.inputs_bad_since else 0.0
if bad_for < stale_after:
# A single missed poll is not a fault. Hold, keep the heartbeat
@@ -223,6 +294,16 @@ class Controller:
claims.append(Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"))
# --- safety stops ----------------------------------------------------
# ⚠️ SAFETY-02 is claimed FIRST and unconditionally while latched. It is
# a SET at P_SAFETY, so it outranks maintenance, peak shaving and the
# loop alike - a controller pushing power the wrong way is wrong
# whatever it thinks it is doing. Re-filed EVERY cycle: claims are not
# sticky, and one filed once would lapse the next cycle and hand the
# actuator silently back to the loop that was driving the wrong way.
if self.sign_wd.tripped:
claims.append(Claim.set("failsafe", P_SAFETY, 0.0,
"sign disagreement"))
if not self.auto:
claims.append(Claim.set("safety", P_SAFETY, 0.0, "stopped"))
elif not self.inputs_ok:
@@ -294,6 +375,20 @@ class Controller:
resolution = resolve(claims)
if resolution.contradiction:
self.log_event("ARBITER CONTRADICTION - commanding 0 W, see the log")
# --- SAFETY-02's arming gate ------------------------------------------
# Was the number about to go on the wire chosen by the grid-following
# loop, or by a strategy that commands against the meter on purpose?
# Only the former is expected to agree in sign with P1 - without this,
# every maintenance grid charge trips the failsafe within three minutes.
#
# ⚠️ THE EXPRESSION LIVES IN watchdog.py, NOT HERE, and that is not
# tidiness. It was inline, test_watchdog.py held a transcription of it,
# and the P_PEAK case meant to force whoever lands peak shaving to come
# and change an expectation did not: editing this line alone to
# `winner in ("loop", "peak")` left every suite green while the watchdog
# went blind for every peak event. Read loop_is_following() before
# touching the gate - the forward hazard and the reasoning are there.
self.following = loop_is_following(resolution, self.loop_w)
self.target = resolution.target_w
self.reason = resolution.explain()
await self.write_setpoint(self.target)
@@ -303,19 +398,112 @@ class Controller:
entity = self.o.get("setpoint_entity", "")
if entity:
self.dev_min, self.dev_max, _ = await self.hass.limits(entity)
if self.dev_max is not None and self.tuning.max_w > self.dev_max:
self.log_event(
f"clamp {self.tuning.max_w:.0f} W exceeds the device maximum "
f"{self.dev_max:.0f} W - the device wins")
# ⚠️ THIS USED TO WARN AND CARRY ON, and that was the bug CFG-01
# exists to remove: a max_w above the device's rating meant
# write_setpoint() silently clamped and the configured ceiling was
# never the real one.
#
# amain() already ran this gate before anything started. It runs
# AGAIN here for one case the gate cannot cover: ESPHome is often
# not up yet when the add-on boots, so hass.limits() returned
# (None, None) and the range checks were skipped rather than
# guessed at. This is the first moment the device's real rating is
# known. If it conflicts, refuse now - stopping deterministically
# through the normal shutdown, which commands 0 W on the way out.
problems = validate_startup_config(self.o, self.dev_min, self.dev_max)
if problems:
refuse(problems)
self.refused = problems
self.log_event("REFUSED: " + problems[0])
# Signal, then return WITHOUT entering the loop. amain() wakes
# on this, runs the normal wind-down (which commands 0 W) and
# re-raises ConfigRefused afterwards, so the exit code is 78 and
# the inverter is left at zero rather than latched.
self.stop_event.set()
return
last_grid = object()
heartbeat = float(self.o.get("heartbeat_s", 10))
last_beat = 0.0
# ⚠️ SAFETY-12. The floor is a DEADLINE ON THE GAP BETWEEN CYCLES, not a
# second scheduler running alongside the arrival trigger. Every cycle
# resets it, whichever trigger fired, so on a healthy changing meter it
# never elapses and not one existing cycle moves - and therefore no
# change to the per-cycle gain the tuning was measured against.
#
# That is true twice over, and the second reason is the sturdier one:
# the combined cycle rate is max(arrival rate, 1/floor), never the sum.
# At the defaults 1/15 s is strictly slower than the ~1/5 s arrival
# rate, so even a floor that raced the arrivals could not push the loop
# past its nominal healthy rate. The re-tune is unreachable by
# construction, not merely by the reset. ⚠️ That argument holds only
# while floor > the meter's update interval - which is why the schema
# minimum of 5 s deserves the second look validate.py has not given it
# yet: 5 s IS the reference meter's interval, i.e. the one configurable
# value that would double the cycle rate.
#
# Why it has to exist, and it is not only about latency: `self.grid !=
# last_grid` alone means a meter that repeats a value runs NO control
# cycles at all. The heartbeat below keeps re-emitting the last command
# and the firmware keeps putting it on the wire, so every indicator
# reads healthy - and, worse, the `inputs missing -> 0 W` claim lives
# INSIDE cycle(), so on a repeating meter THAT SAFETY CLAIM CANNOT FIRE.
# Demonstrated in test_loop.py: constant meter, SoC entity dies at t=4 s,
# and the pre-fix controller holds 220 W through the whole outage with
# the status line still reading "loop -> 220 W". Layer 1 does not cover
# it on a `meter_source: off` install either - no P1 age sensor is
# published, so the firmware has nothing to veto on. Measured on the rig
# during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals, zero
# cycles.
#
# This is NOT a freeze detector, and deliberately so - see
# HomeWizardLocalSource.unchanged_s for why one cannot be built here (at
# the converged -10 W target a 1 Wh register needs ~6 minutes to move,
# so any freeze threshold false-trips at the exact operating point we
# run at). Nothing here decides whether a repeated reading is true. It
# only stops "the number is the same" from meaning "do not think".
#
# ⚠️ THE 15 s DEFAULT HAS A CEILING IT DOES NOT OWN. It is under
# validate.FIRMWARE_INGEST_VETO_S (30 s) and under meter_max_age_s on
# purpose, so the loop re-decides at least twice inside any window in
# which layer 1 might otherwise be the only thing deciding. If the
# firmware's veto ever moves, this default moves with it - it is not
# independently justified at 15.
floor = float(self.o.get("cycle_floor_s", 15))
last_cycle = None
while not self.stopping:
await self.read_inputs()
# A cycle is one meter update, exactly as on the reference install.
if self.grid != last_grid:
now_mono = asyncio.get_running_loop().time()
# A cycle is one meter update, exactly as on the reference install -
# or the floor elapsing, whichever comes first.
overdue = last_cycle is None or (now_mono - last_cycle) >= floor
if self.grid != last_grid or overdue:
last_grid = self.grid
last_cycle = now_mono
# ⚠️ The FULL cycle, not a degraded one. A floor cycle runs the
# same law on the same inputs as an arrival cycle, because in P1
# mode the freshness question is already answered upstream and
# answered harder: past `meter_max_age_s` (30 s) p1.net_w is
# None, which is "inputs missing", which becomes a P_SAFETY 0 W
# claim. So a floor cycle cannot run the PI on a 60 s old
# figure, because at 60 s there is no figure.
#
# ⚠️ THAT GUARANTEE IS TRANSPORT-CONDITIONAL, and saying so
# matters more than the guarantee: with `meter_source: off`,
# read_inputs() takes self.grid straight from hass.number() with
# NO age gate at all, so a Home Assistant entity that has gone
# quiet reads as a current value on that path with or without
# this change. Running the full law is still the right choice
# there - the alternative is a degraded second law reasoning
# about an age nobody measured - but the floor does not make
# that path fresh, and nothing here should be read as claiming
# it does. And the integrator
# advances per CYCLE, not per second (control.py), so bounding
# the gap bounds the accumulation: at most one extra
# gain x error per floor interval, under the same
# integrator_max_w as every other cycle. A second, gentler
# control law for floor cycles would be a second set of
# dynamics nobody can test on this hardware.
await self.cycle()
# ⚠️ The heartbeat is not an optimisation. The ESP32 treats silence
# longer than ~30 s as "the controller is gone" and zeroes the
@@ -334,10 +522,18 @@ class Controller:
"battery": self.batt,
"soc": self.soc,
"phase": self.maint.phase,
"status": "running" if self.auto else "stopped",
# ⚠️ SAFETY-02's alarm surface, and it is deliberately an existing
# one. IF-01/IF-02 own `ems/event/failsafe` and the `failsafe active`
# binary sensor and neither is built yet; inventing a bespoke topic
# here would be a surface to migrate later. This sensor is already
# discovered, already on every dashboard, and "failsafe" is
# additive to its vocabulary rather than a change to it.
"status": ("failsafe" if self.sign_wd.tripped
else "running" if self.auto else "stopped"),
}
# ⚠️ ONLY when P1 ingestion is actually running. The ESP32's stale-input
# watchdog subscribes to sensor.p1_sample_age_s and forces the layer-1
# watchdog subscribes to sensor.goodwe_p1_sample_age - see the entity-id
# note in mqtt.py; the composed name is not the object_id - and forces layer-1
# failsafe once it reaches max_age_s. With meter_source off there is no
# ingester feeding it, so published_age_s would be time-since-startup
# climbing without bound - i.e. every existing install would cross the
@@ -415,6 +611,23 @@ class Controller:
out.append({"ok": False, "warn": False,
"text": "last write to the inverter was REJECTED - check the log"})
# SAFETY-02. Reported in both states: a watchdog nobody can see is armed
# is a watchdog nobody trusts when it fires.
if self.sign_wd.tripped:
out.append({"ok": False, "warn": False,
"text": "SIGN-DISAGREEMENT FAILSAFE - " + self.sign_wd.reason
+ ". The inverter is held at 0 W. Find out why the "
"command opposed the meter before starting control "
"again; starting clears this. Restarting the "
"add-on does NOT clear it."})
else:
held = self.sign_wd.held_s(datetime.now(timezone.utc))
out.append({"ok": True, "warn": False,
"text": f"sign watchdog: armed (trips after "
f"{self.sign_wd.cfg.hold_s:.0f} s opposed, both over "
f"{self.sign_wd.cfg.min_w:.0f} W)"
+ (f" - opposed for {held:.0f} s now" if held else "")})
if not o.get("estop_fitted", False):
out.append({"ok": False, "warn": True,
"text": "no e-stop fitted: if this host dies the battery stays "
@@ -432,7 +645,11 @@ class Controller:
def status_payload(self) -> dict:
checks = self.checks()
bad = [c for c in checks if not c["ok"] and not c["warn"]]
if bad:
if self.sign_wd.tripped:
# Outranks "NOT READY": nothing is missing, something went wrong.
level, banner = "bad", ("FAILSAFE — the command opposed the meter. "
"Inverter held at 0 W.")
elif bad:
level, banner = "bad", f"NOT READY — {bad[0]['text']}"
elif not self.auto:
level, banner = "warn", "Stopped — inverter commanded to 0 W"
@@ -466,6 +683,17 @@ class Controller:
self.auto = not self.auto
self.store.set("auto", self.auto)
self.log_event("control started" if self.auto else "control stopped")
if self.auto and self.sign_wd.tripped:
# ⚠️ THE ONLY WAY OUT OF A SIGN-DISAGREEMENT TRIP, on purpose.
# It clears on a deliberate human start, not on the condition
# going away - the condition ALWAYS goes away, because the trip
# commands 0 W and a 0 W command cannot disagree with anything.
# An operator pressing start has, at minimum, looked at the
# banner that says why.
self.sign_wd.reset()
self.store.set("sign_tripped", False)
self.store.set("sign_reason", "")
self.log_event("sign-disagreement failsafe cleared by operator")
if not self.auto:
self.target = 0.0
await self.write_setpoint(0.0, force=True)
@@ -514,6 +742,26 @@ async def amain() -> None:
except Exception as _e: # noqa: BLE001
_LOG.error("core api probe failed: %s", _e)
# ⚠️ THE STARTUP GATE (CFG-01). Nothing below this line may run on a
# configuration validate.py rejects - specs §1.5: a config the system
# cannot honour is refused at startup, not survived at runtime.
#
# It sits HERE, before the broker, before the web server and before any
# task exists, so a refusal cannot leave half a controller running with
# a UI in front of it. Reading the device range is the one thing the
# validator cannot do for itself; (None, None) when ESPHome has not come
# up yet is not a refusal - run_control() re-checks once the real rating
# is known. See validate.py for where the line is drawn and why.
_sp = str(opts.get("setpoint_entity", "") or "").strip()
_dev_min = _dev_max = None
if _sp:
_dev_min, _dev_max, _ = await hass.limits(_sp)
_LOG.info("setpoint device %s reports range %s…%s W", _sp, _dev_min, _dev_max)
_problems = validate_startup_config(opts, _dev_min, _dev_max)
if _problems:
refuse(_problems)
raise ConfigRefused(_problems)
# ⚠️ Status publishing must NEVER be able to stop the controller. A
# broken broker, a missing library, an API change in paho - all of it is
# observability, and the battery does not care. Caught broadly and on
@@ -539,10 +787,10 @@ async def amain() -> None:
pub = _NoMqtt()
controller = Controller(opts, hass, store, pub)
stop = asyncio.Event()
controller = Controller(opts, hass, store, pub, stop=stop)
runner = await web.start(controller, port=8099)
stop = asyncio.Event()
loop = asyncio.get_running_loop()
for sig in (signal.SIGTERM, signal.SIGINT):
with contextlib.suppress(NotImplementedError):
@@ -569,6 +817,10 @@ async def amain() -> None:
await task
await runner.cleanup()
_LOG.info("stopped")
# The late-arriving-device refusal from run_control(). Re-raised only
# now, so the wind-down above still ran and the inverter is at 0 W.
if controller.refused:
raise ConfigRefused(controller.refused)
def main() -> None:
@@ -576,6 +828,13 @@ def main() -> None:
asyncio.run(amain())
except KeyboardInterrupt:
pass
except ConfigRefused:
# ⚠️ No traceback, on purpose. The banner refuse() already printed says
# everything an operator needs, and a stack trace on top of it would say
# "this crashed" - the exact confusion AC3 is about. 78 is sysexits(3)
# EX_CONFIG, so even a script reading the exit status can tell a bad
# config from a bug.
raise SystemExit(78)
if __name__ == "__main__":
+4 -3
View File
@@ -28,9 +28,10 @@ _LOG = logging.getLogger("goodwe.maint")
IDLE, DRAIN, CHARGE, HOLD = "idle", "drain", "charge", "hold"
# A drain of a 13.5 kWh usable pack at 2500 W is ~5 h even with no house load
# helping. 12 h means the battery is not following commands - a fault, not a
# slow day. The charge phase deliberately waits for sun and for cheap hours, so
# A drain of a 13.8 kWh usable pack (300 Ah x 51.2 V, DoD 90) at the shipped
# 2000 W is ~6.9 h even with no house load helping - and less in practice, since
# house load drains alongside the export and soc_floor stops short of empty.
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
# it is expected to span a night; 36 h still bounds it.
DRAIN_TIMEOUT_MIN = 720
CHARGE_TIMEOUT_MIN = 2160
+26 -7
View File
@@ -45,13 +45,32 @@ SENSORS = [
("soc", "goodwe_battery_soc", "Battery SoC", "%", "battery", "measurement", None),
("phase", "goodwe_maintenance_phase", "Maintenance phase", None, None, None, "mdi:battery-sync"),
("status", "goodwe_controller_status", "Controller status", None, None, None, "mdi:heart-pulse"),
# ⚠️ This one deliberately breaks the goodwe_ prefix above: the entity id
# must be exactly `sensor.p1_sample_age_s`, because SAFETY-01's firmware
# watchdog subscribes to that literal id and the ENV-01 simulation rig
# asserts on it. Renaming it silently disarms a safety layer. It is seconds
# since the newest accepted P1 telegram, republished every second so that a
# meter frozen at a constant value still shows a climbing age - which is the
# false-trip that this entity exists to remove.
# ⚠️ THE LIVE ENTITY IS `sensor.goodwe_p1_sample_age`, NOT what this
# object_id spells. An earlier version of this comment said the id "must be
# exactly sensor.p1_sample_age_s" - that name has never existed on any HA,
# and believing it is how a safety layer gets disarmed by someone tidying up.
#
# On HA 2026.8 `object_id` in a discovery payload does NOT determine the
# entity_id. HA composes it from the device name plus the entity name:
# "GoodWe RS485 Controller" + "P1 sample age" -> sensor.goodwe_p1_sample_age.
# Verified against the live system 2026-08-26; the firmware subscribes to
# that composed name (goodwe-master-stage4-failsafe.yaml, homeassistant
# sensor p1_age_s), and its own comment records that sensor.p1_sample_age_s
# never existed.
#
# So: do NOT "fix" the firmware to match the object_id below, and do not
# rename the device or this entity's friendly name - either changes the
# composed id and silently disarms the ingest guard, because has_state()
# simply stays false forever and nothing reports it. The firmware calls this
# out as the failure that "FAILS SILENTLY AND LOOKS CORRECT".
#
# The value: seconds since the newest accepted P1 telegram, republished
# every second so a meter frozen at a constant value still shows a climbing
# age - the false-trip this entity exists to remove.
#
# ⚠️ Separately, and not fixed here: the firmware's ingest guard tests this
# sensor's VALUE rather than its arrival, so a dead publisher freezes the
# number and reads permanently fresh. Filed as TEL-06.
("p1_age", "p1_sample_age_s", "P1 sample age", "s", "duration", "measurement", None),
]
+130 -67
View File
@@ -1044,15 +1044,133 @@ def is_enabled(opts: dict) -> bool:
return str(opts.get("meter_source", "off") or "off").strip() not in ("off", "")
def homewizard_host_port(opts: dict) -> tuple[str, str]:
"""`p1_host` split into host and (still unparsed) port text.
One definition because validate_meter_options() and build_source() must
agree byte for byte about what counts as a usable address - a pasted browser
URL is the obvious way to fill this in wrong.
"""
host = str(opts.get("p1_host", "") or "").strip()
host = host.removeprefix("http://").removeprefix("https://").rstrip("/")
host, _, port_s = host.partition(":")
return host, port_s
def validate_meter_options(opts: dict, phases: int, max_age_s: float) -> list[str]:
"""Every way `meter_source` can name a meter that will never produce a reading.
⚠️ THIS IS THE ONLY PLACE THAT KNOWS THESE RULES. It used to be a run of
inline `return None`s inside build_source(); CFG-01 lifted them out because
the same predicates now have two callers with two different consequences:
validate.validate_startup_config() refuses to start the add-on
build_source() returns None, as it always did
They are one function and not two on purpose. A second copy of "what makes a
meter config wrong" would drift, and the half that drifted would be the one
that decides whether the process is allowed to run.
Checked ONCE at startup rather than per telegram, because a misconfigured
source otherwise fails in the one way indistinguishable from a healthy source
nobody has sent anything to yet: no samples, a climbing age, the firmware
watchdog holding the battery at 0 W, and nothing in the log saying why.
Returns a list of human-readable problems; empty means the config is usable.
`phases` and `max_age_s` are passed in rather than read from opts so the
caller decides whether it is validating the options or an already-built
P1Ingest - build_source() has an ingest whose values may not have come from
this dict.
"""
source = str(opts.get("meter_source", "off") or "off").strip()
if source in ("off", ""):
return []
problems: list[str] = []
if source == SOURCE_HA:
imp = str(opts.get("p1_import_entity", "") or "").strip()
exp = str(opts.get("p1_export_entity", "") or "").strip()
if not imp or not exp:
problems.append(
f"meter_source {SOURCE_HA} needs both p1_import_entity and "
f"p1_export_entity (got {imp or '<blank>'!r} / {exp or '<blank>'!r})")
elif source == SOURCE_HA_SIGNED:
net = str(opts.get("p1_net_entity", "") or "").strip()
phase_net = [str(e).strip() for e in
(opts.get("p1_phase_net_entities") or []) if str(e).strip()]
if not net:
problems.append(
f"meter_source {SOURCE_HA_SIGNED} needs p1_net_entity "
"(sensor.p1_sample_age_s would otherwise be announced with "
"nothing feeding it)")
if phase_net and len(phase_net) != phases:
problems.append(
f"p1_phase_net_entities has {len(phase_net)} entities but "
f"meter_phases is {phases} - every telegram would be rejected "
"on the phase-count check")
elif source == SOURCE_MQTT:
if not str(opts.get("meter_mqtt_topic", "") or "").strip():
problems.append(f"meter_source {SOURCE_MQTT} needs meter_mqtt_topic")
elif source == SOURCE_HOMEWIZARD:
host, port_s = homewizard_host_port(opts)
if not host:
problems.append(
f"meter_source {SOURCE_HOMEWIZARD} needs p1_host (the meter's "
"own address, e.g. 192.168.2.250)")
if port_s:
try:
int(port_s)
except ValueError:
problems.append(f"p1_host {opts.get('p1_host')!r} has an "
"unparseable port")
try:
# ⚠️ Not `or 5`: that turns an explicit 0 into the default, and a
# cadence of 0 is a misconfiguration that must be reported, not
# quietly corrected into something that looks like it was asked for.
raw = opts.get("meter_poll_s", 5)
poll_s = float(5 if raw is None or raw == "" else raw)
except (TypeError, ValueError):
problems.append(f"meter_poll_s {opts.get('meter_poll_s')!r} is not a number")
else:
if poll_s <= 0:
problems.append("meter_poll_s must be positive")
# ⚠️ The age can never be fresher than the poll interval. At or past
# max_age_s every reading is stale before its successor arrives, so
# the controller would sit permanently on missing inputs while the
# meter is perfectly healthy - refuse it rather than ship that.
elif poll_s >= max_age_s:
problems.append(
f"meter_poll_s {poll_s:.1f} is not under meter_max_age_s "
f"{max_age_s:.1f} - every reading would go stale before the "
"next poll")
else:
problems.append(
f"meter_source {source!r} is not one of "
+ ", ".join((SOURCE_HA, SOURCE_MQTT, SOURCE_HA_SIGNED, SOURCE_HOMEWIZARD)))
return problems
def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
"""Return the transport named by `meter_source`, or None if disabled.
This is the whole of AC 1's "switchable": every consumer reads P1Ingest, so
changing transport is a config edit, never a code path.
⚠️ In the add-on this is now unreachable with a bad config -
validate_startup_config() refuses to start on anything
validate_meter_options() rejects. The guard stays because this function is
also called directly by tests and by anything embedding P1Ingest, and
"returns None" is a safer default for those callers than a transport that
can never read.
"""
source = str(opts.get("meter_source", "off") or "off").strip()
if not is_enabled(opts):
return None
problems = validate_meter_options(opts, ingest.phases, ingest.max_age_s)
if problems:
for problem in problems:
_LOG.error("%s - P1 ingestion disabled", problem)
return None
if source == SOURCE_HA:
return HaDsmrSource(session, ingest, {
"import": opts.get("p1_import_entity", ""),
@@ -1061,70 +1179,19 @@ def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
"phase_export": opts.get("p1_phase_export_entities") or [],
})
if source == SOURCE_HA_SIGNED:
net = str(opts.get("p1_net_entity", "") or "").strip()
phase_net = [str(e).strip() for e in
(opts.get("p1_phase_net_entities") or []) if str(e).strip()]
# ⚠️ Both of these are checked ONCE here rather than per telegram. A
# misconfigured source otherwise fails silently in the only way that
# looks exactly like a healthy one that has not been sent anything yet:
# no samples, a climbing age, and the firmware watchdog holding the
# battery at 0 W with nothing in the log saying why.
if not net:
_LOG.error("meter_source %s needs p1_net_entity - P1 ingestion "
"disabled (sensor.p1_sample_age_s would otherwise be "
"announced with nothing feeding it)", SOURCE_HA_SIGNED)
return None
if phase_net and len(phase_net) != ingest.phases:
_LOG.error("p1_phase_net_entities has %d entities but meter_phases "
"is %d - P1 ingestion disabled. Every telegram would be "
"rejected on the phase-count check.",
len(phase_net), ingest.phases)
return None
return HaSignedSource(session, ingest,
{"net": net, "phase_net": phase_net})
return HaSignedSource(session, ingest, {
"net": str(opts.get("p1_net_entity", "") or "").strip(),
"phase_net": [str(e).strip() for e in
(opts.get("p1_phase_net_entities") or []) if str(e).strip()],
})
if source == SOURCE_HOMEWIZARD:
host = str(opts.get("p1_host", "") or "").strip()
# A pasted browser URL is the obvious way to fill this in wrong.
host = host.removeprefix("http://").removeprefix("https://").rstrip("/")
host, _, port_s = host.partition(":")
# ⚠️ Checked ONCE here, like the ha_signed entity ids and for the same
# reason: a misconfigured source otherwise fails in the one way that
# looks exactly like a healthy one nobody has sent anything to yet - no
# samples, a climbing age, the watchdog holding the battery at 0 W, and
# nothing in the log saying why.
if not host:
_LOG.error("meter_source %s needs p1_host (the meter's own address, "
"e.g. 192.168.2.250) - P1 ingestion disabled",
SOURCE_HOMEWIZARD)
return None
try:
port = int(port_s) if port_s else HOMEWIZARD_PORT
except ValueError:
_LOG.error("p1_host %r has an unparseable port - P1 ingestion disabled",
opts.get("p1_host"))
return None
try:
# ⚠️ Not `or 5`: that turns an explicit 0 into the default, and a
# cadence of 0 is a misconfiguration that must be reported, not
# quietly corrected into something that looks like it was asked for.
raw = opts.get("meter_poll_s", 5)
poll_s = float(5 if raw is None or raw == "" else raw)
except (TypeError, ValueError):
_LOG.error("meter_poll_s %r is not a number - P1 ingestion disabled",
opts.get("meter_poll_s"))
return None
if poll_s <= 0:
_LOG.error("meter_poll_s must be positive - P1 ingestion disabled")
return None
# ⚠️ The age can never be fresher than the poll interval. At or past
# max_age_s every reading is stale before its successor arrives, so the
# controller would sit permanently on missing inputs while the meter is
# perfectly healthy - refuse it rather than ship that.
if poll_s >= ingest.max_age_s:
_LOG.error("meter_poll_s %.1f is not under meter_max_age_s %.1f - every "
"reading would go stale before the next poll. P1 ingestion "
"disabled.", poll_s, ingest.max_age_s)
return None
host, port_s = homewizard_host_port(opts)
port = int(port_s) if port_s else HOMEWIZARD_PORT
raw = opts.get("meter_poll_s", 5)
poll_s = float(5 if raw is None or raw == "" else raw)
# A warning, not a refusal: one missed poll costs a stale reading and a
# 0 W cycle, which is fail-safe. The refusal above is for cadences that
# can NEVER be fresh.
if poll_s > ingest.max_age_s / 2:
_LOG.warning("meter_poll_s %.1f leaves no room under meter_max_age_s "
"%.1f: one missed poll makes the reading stale. The meter "
@@ -1136,8 +1203,4 @@ def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
return MqttP1Source(ingest, str(opts.get("meter_mqtt_topic", "")),
broker.get("host"), broker.get("port", 1883),
broker.get("username"), broker.get("password"))
if source:
_LOG.error("meter_source %r is not one of %s - P1 ingestion disabled",
source, ", ".join((SOURCE_HA, SOURCE_MQTT, SOURCE_HA_SIGNED,
SOURCE_HOMEWIZARD)))
return None
+23 -2
View File
@@ -22,11 +22,30 @@ _LOG = logging.getLogger("goodwe.store")
# `auto_start` option only when the key is absent - if a default supplied False,
# the fallback could never fire and auto_start would silently do nothing on
# every fresh install.
#
# ⚠️ `sign_tripped` IS in here, and the difference from `auto` is the whole
# reason both decisions are written down. `auto` has an option to fall back to
# (`auto_start`), so a stored default would mask a fresh install. A latched
# failsafe has no such fallback: absent means "never tripped", which is exactly
# what a default of False says.
#
# It is persisted for the reason this module's docstring gives for maintenance
# state, applied to something with a much shorter fuse. SAFETY-02's latch is the
# only thing standing between a controller that has been caught driving the wrong
# way and its own restart, and "restart the add-on" is the FIRST thing an operator
# looking at a FAILSAFE banner will try. Held only in memory it came back armed,
# into the fault, unattended - measured: after reconstructing Controller against
# the same store, `tripped` was False, the banner read NOT READY, and it resumed
# commanding -1000, -2000 W before re-tripping 180 s later. Under a supervisor
# that restarts a crashed add-on that is a loop, three minutes of wrong-direction
# power at a time, forever.
DEFAULTS = {
"phase": "idle",
"phase_started": None,
"last_completed": None,
"last_start_attempt": None,
"sign_tripped": False,
"sign_reason": "",
}
@@ -42,8 +61,10 @@ class Store:
loaded = json.load(fh)
if isinstance(loaded, dict):
self.data = {**DEFAULTS, **loaded}
_LOG.info("state restored: phase=%s last_completed=%s",
self.data.get("phase"), self.data.get("last_completed"))
_LOG.info("state restored: phase=%s last_completed=%s "
"sign_tripped=%s",
self.data.get("phase"), self.data.get("last_completed"),
self.data.get("sign_tripped"))
except FileNotFoundError:
_LOG.info("no saved state, starting fresh")
except (json.JSONDecodeError, OSError) as err:
+414
View File
@@ -0,0 +1,414 @@
"""Startup configuration validation - the gate before the control loop runs.
WHAT THIS IS FOR, in one sentence: some configurations are not "a bit off", they
are configurations under which the add-on's own safety machinery does not work,
and for those the correct behaviour is to refuse to start rather than to log a
line and carry on.
⚠️ THE FAILURE THIS REPLACES. `main.py` used to read the setpoint device's own
±5000 W rating, notice that a configured `max_w` of, say, 8000 W exceeded it,
write one WARNING to a log nobody reads, and then run anyway with
`write_setpoint()` quietly clamping. The operator's stated ceiling was simply not
the ceiling, and the only evidence was a line that had scrolled off. specs §1.5
is explicit that a configuration in which the system cannot honour what it was
told is refused at startup, not survived at runtime.
WHERE THE LINE IS DRAWN, and why it is not further out. A validator that refuses
on trivia gets switched off by the first person it inconveniences, so this one
refuses only where **continuing produces one of two outcomes:**
(a) **a stated limit is untrue** - the operator configured a bound, a lower
layer silently enforces a different one, and nothing says which won; or
(b) **the add-on is inert and indistinguishable from healthy** - it starts,
serves its UI, reports green, and moves no energy, with no symptom that
separates it from a correctly-idle system.
⚠️ (b) IS NOT A SPECIAL CASE OF (a), and an earlier draft of this file wrongly
implied it was by claiming every refusal here "makes a safety mechanism
inoperative". It does not: when `setpoint_entity` is blank, layer 1 pinning the
inverter at 0 W is the failsafe WORKING. The problem is not that the system
becomes unsafe, it is that it becomes a very convincing impression of a working
controller - and an operator has no way to tell. That is its own reason to
refuse, and stating it as one is what stops the rule being stretched later to
cover mere untidiness.
Both halves have to stay narrow. (a) is not "any two numbers that could
disagree"; it is a bound the operator SET being overridden by a layer they
cannot see. (b) is not "anything degraded"; it is inert AND silent - if a red
NOT READY banner already names the problem, (b) does not apply.
1. `max_w` outside the setpoint device's own rating. [(a)]
The stated limit is untrue. arbiter.py's `supervised` SAFETY claim says the
output is bounded by ±max_w; it is not, it is bounded by the device, and the
two numbers disagree. Which one wins is a coin toss to anyone reading the
config.
2. No `setpoint_entity`. [(b)]
A controller with no actuator, and nothing about it looks broken.
`write_setpoint()` returns immediately on a blank entity, so: no device
rating is ever read (the `device` SAFETY claim is never made at all), and
the ESP32 heartbeat - the thing that feeds LAYER 1 - never happens. The
add-on serves a UI, publishes MQTT, resolves claims, and moves nothing.
Layer 1 then holds the inverter at 0 W, which is the failsafe working
exactly as designed - this is (b), not (a). Nothing is unsafe; it is simply
impossible to tell from the outside that the thing is doing nothing.
3. A `meter_source` that can never produce a reading. [(b)]
§5.1 makes P1 the only authoritative measurement and deliberately provides
no fallback, so a transport that cannot be built means `grid` is None
forever: permanent "inputs missing", 0 W, and a status page that reports a
meter with a climbing age exactly as it would for a healthy meter nobody has
sent anything to yet. The predicates live in `p1.validate_meter_options()`,
which is also what `build_source()` uses - one definition, two callers.
4. `meter_max_age_s` above the firmware's own ingest veto. [(a)]
The purest example of (a) in the system, and structurally the same fault as
1. The add-on's schema accepts `int(5,300)`. The firmware's threshold is a
COMPILE-TIME SUBSTITUTION - `max_age_s: "30"` in
goodwe-master-stage4-failsafe.yaml - used by both its monotonic receipt
clock and its `ingest_stale` veto, which trips layer 1 on
`p1_age_s >= 30`. Set 120 and the add-on believes a 119 s reading is fresh
and keeps commanding into it, while the firmware vetoed at 30 s and is
holding the inverter at 0 W. Status page: healthy meter, running
controller, nothing moving, and no line anywhere saying the number you set
was overruled. That firmware file's own comment says a lower bound on this
"belongs in CFG-01, not here" - so here it is.
5. `sign_disagree_w` at or above `max_w`. [(a)]
The arbiter's `supervised` limit bounds every command to +-max_w, and
SAFETY-02's predicate needs `abs(command) > sign_disagree_w`. Set the
threshold at or above the ceiling and the command side of the comparison
is unsatisfiable BY CONSTRUCTION: the watchdog can never fire, on any
input, ever. Same shape as 1 and 4 - the operator set a number, a layer
they cannot see makes it mean something else, and nothing says so. Worse
here, because what the status page reports in that state is "sign
watchdog: armed". A disarmed guard that advertises itself as armed is the
one thing this project has decided repeatedly it will not ship.
6. `maintenance_charge_w` above `max_w`. [(a)]
The same shape as 5, and found the same way - by checking a worked example
against what actually ships. maintenance's cheap-window shaping files
`Claim.limit(hi=-maintenance_charge_w)` at P_MAINT_SHAPE, against the
`supervised` SAFETY limit's `lo=-max_w`. Both bind (P_SAFETY and
P_MAINT_SHAPE both outrank the loop that wins the SET), so a charge rate
above the ceiling gives `lo > hi` - the arbiter's clause 3, which it
correctly resolves to 0 W and logs as a CONTRADICTION. Measured against
the arbiter, loop asking +500 W:
max_w=2000 hi=-2500 -> +0 W contradiction=True
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(...)
So MAINTENANCE SILENTLY NEVER CHARGES IN A CHEAP WINDOW until max_w is at
or above the charge rate, and the only evidence is a contradiction line
that reads like a bug in the arbiter rather than like the two numbers the
operator set. Equality is fine and deliberately not refused - at
max_w == charge_w the window is a single reachable point, -max_w.
⚠️ `maintenance_discharge_w` IS NOT THE SAME CASE, and this was checked
rather than assumed. THE SHAPING IS NOT SYMMETRIC: the drain phase does
not shape the loop, it OWNS the actuator - `Claim.set(P_MAINTENANCE,
+discharge_w)`. A SET is clamped by the limits above it, not contradicted
by them, so 2500 against a 2000 W ceiling emits +2000 W and the arbiter's
own explain() says `maintenance -> 2000 W, limited by supervised(max_w)`
on the status page every cycle. That is neither (a) - nothing is silent -
nor (b) - it moves energy and the cycle still completes, just slower
(13.8 kWh usable at 2000 W is ~6.9 h against the 720 min DRAIN_TIMEOUT).
It is warned about below, not refused.
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
extra headroom buys is more wrong-direction power to unwind after
saturation - but the arbiter's `supervised` limit still binds the wire to
±max_w, so nothing out of range ever reaches the inverter. The cost is
latency, not amperage. Warned about, not refused.
- A missing `soc_entity` / `batt_entity`. `inputs_ok` goes False, the loop
commands 0 W, and `checks()` already renders a red NOT READY banner naming
the missing entity. Fail-safe AND already loud; a refusal adds nothing.
- A `setpoint_entity` that exists in the config but is not found on the Core
API at startup. This is the transient case - ESPHome is frequently not up
yet when the add-on boots - and refusing here would turn a device that
arrives thirty seconds late into a restart loop needing a human. It stays a
NOT READY banner.
- `meter_poll_s` above half `meter_max_age_s`. One missed poll costs a stale
reading and a 0 W cycle. Warned about in p1.py, not refused.
- `maintenance_discharge_w` above `max_w`. Clamped, not contradicted, and the
clamp names itself in the arbiter's explain() - see rule 6. Warned about,
not refused.
"""
import logging
from .p1 import is_enabled, validate_meter_options
_LOG = logging.getLogger("goodwe.config")
# ⚠️ A MIRROR OF A FIRMWARE CONSTANT, AND IT CANNOT BE IMPORTED. The firmware
# threshold is a compile-time YAML substitution baked into the ESP32 image
# (`max_age_s: "30"`, master/goodwe-master-stage4-failsafe.yaml), so nothing at
# runtime can ask the board what value it was built with. This number is a copy,
# and a copy of a constant in another repo is a thing that goes stale.
#
# What makes that acceptable here: the copy can only ever be WRONG IN THE SAFE
# DIRECTION for the check below. If the firmware's veto is raised above 30, this
# refuses some configs that would in fact have worked - annoying, visible
# immediately, and fixed by editing one line. It cannot start accepting a config
# the firmware vetoes unless the firmware's number goes DOWN, which would be a
# tightening nobody does silently.
#
# ⚠️ TEL-06 IS EDITING `ingest_stale` DIRECTLY. If that ticket changes what the
# veto MEANS - e.g. thresholding arrival rather than the sensor's value - this
# constant's justification has to be re-read, not just its number. Do not assume
# a matching integer means a matching rule.
FIRMWARE_INGEST_VETO_S = 30.0
# ⚠️ The complete set of option keys through which this add-on can reach an
# actuator. specs §1.5 makes "any configuration in which two writers can reach
# one actuator" a non-goal, and the way that non-goal is ENFORCED here is by
# construction: there is exactly one such key, so a second writer is not
# expressible in the options schema at all. sim/inject.py's `two_writers`
# scenario asserts on this tuple - if a second write path is ever added, that
# scenario goes red and somebody has to decide how the two are arbitrated
# BEFORE the config that allows both can ship.
ACTUATOR_WRITE_KEYS = ("setpoint_entity",)
class ConfigRefused(Exception):
"""The configuration is wrong. Not "something broke" - see main.py's handler.
Carries the list of problems so the caller can render them; str() is the
first one, so an unhandled traceback still names something useful.
"""
def __init__(self, problems: list[str]):
self.problems = problems
super().__init__(problems[0] if problems else "configuration refused")
def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]:
"""Return the list of reasons this configuration must not be started.
Empty list means go. `dev_min`/`dev_max` are the setpoint device's own
reported range (`hass.limits()`), or None when the device could not be
reached - in which case the range checks are skipped rather than guessed at,
for the transient reason in this module's docstring.
Pure and side-effect free apart from two warnings, so it can be called from
a test or from sim/inject.py without a Home Assistant anywhere near it.
"""
problems: list[str] = []
# --- 1. an actuator to write to ------------------------------------------
writers = [k for k in ACTUATOR_WRITE_KEYS
if str(opts.get(k, "") or "").strip()]
if not writers:
problems.append(
"setpoint_entity is not set, so this add-on has no actuator: every "
"write is a no-op, the device's own rating is never read, and the "
"ESP32 heartbeat that holds off the layer-1 failsafe never happens. "
"It would run, look healthy, and move no energy at all. Set it to "
"the ESPHome number entity that carries the setpoint.")
# --- 2. the configured ceiling against the device's own rating -----------
max_w = _number(opts, "max_w", 2000.0)
if max_w is None:
problems.append(f"max_w {opts.get('max_w')!r} is not a number")
# ⚠️ config.yaml's int(100,5000) already blocks this on a real install, so
# the check is not for the Supervisor path - it is because
# validate_startup_config() is now also sim/inject.py's entry point and can
# be handed any dict at all. A max_w of 0 or below inverts the arbiter's
# `supervised` bounds (lo=-max_w becomes the HIGHER number), and a limit
# claim whose lo exceeds its hi is exactly the contradiction the arbiter
# resolves to 0 W - i.e. it would look like a safety trip rather than the
# nonsense config it is.
elif max_w <= 0:
problems.append(
f"max_w is {max_w:.0f} W and must be positive - it is a magnitude, "
"not a signed setpoint. At or below zero the arbiter's supervised "
f"limit becomes lo={-max_w:.0f} / hi={max_w:.0f}, which is a "
"contradiction it resolves to 0 W, so the controller would look "
"like it was tripping rather than misconfigured.")
elif dev_max is not None and max_w > dev_max:
problems.append(
f"max_w is {max_w:.0f} W but {opts.get('setpoint_entity') or 'the setpoint device'} accepts at "
f"most {dev_max:.0f} W - THE DEVICE WINS, so the {max_w:.0f} W you "
f"configured would silently never happen. Lower max_w to "
f"{dev_max:.0f} W or less, or point setpoint_entity at a device that "
f"can take {max_w:.0f} W.")
elif dev_min is not None and -max_w < dev_min:
problems.append(
f"max_w is {max_w:.0f} W, so this controller may command "
f"{-max_w:.0f} W, but {opts.get('setpoint_entity') or 'the setpoint device'} accepts no less "
f"than {dev_min:.0f} W - THE DEVICE WINS on the charge side. Lower "
f"max_w to {abs(dev_min):.0f} W or less.")
# --- 3. a meter that can actually read -----------------------------------
# ⚠️ Not a second copy of these rules - p1.py owns them, because
# build_source() has to apply the identical predicates and a drifted copy
# would be worse than no check.
phases = _number(opts, "meter_phases", 1.0)
max_age_s = _number(opts, "meter_max_age_s", 30.0)
if phases is None or max_age_s is None:
problems.append("meter_phases and meter_max_age_s must both be numbers "
f"(got {opts.get('meter_phases')!r} / "
f"{opts.get('meter_max_age_s')!r})")
else:
problems.extend(validate_meter_options(opts, int(phases), max_age_s))
# --- 4. the staleness window the FIRMWARE will actually enforce -----------
# ⚠️ Only when P1 ingestion is on, and that is a real scope limit rather than
# caution: meter_max_age_s is read by nothing but P1Ingest, and the veto it
# collides with keys off `p1_age_s.has_state()`, which is only ever published
# when ingestion is running (see Controller.publish()). With meter_source off
# there is no sensor, the veto is inert, and the number governs nothing.
#
# Strictly greater, not >=: the firmware trips at `>= 30` and P1Ingest goes
# stale at `> max_age_s`, so 30 against 30 has the firmware fractionally
# stricter by one sample. That is the shipped default and the tested pair.
# BELOW 30 is fine and deliberately not refused - the add-on then gives up
# first, which is fail-safe and visible on its own status page. Only ABOVE is
# the silent case, where the add-on keeps commanding into a reading the board
# has already rejected.
if (is_enabled(opts) and max_age_s is not None
and max_age_s > FIRMWARE_INGEST_VETO_S):
problems.append(
f"meter_max_age_s is {max_age_s:.0f} s but the ESP32 firmware vetoes "
f"any P1 sample at {FIRMWARE_INGEST_VETO_S:.0f} s and forces the "
"layer-1 failsafe - THE FIRMWARE WINS, and it wins silently. This "
f"add-on would treat a {max_age_s - 1:.0f} s reading as fresh and "
"keep commanding, while the inverter sat at 0 W with a healthy-"
"looking meter on the status page. Lower meter_max_age_s to "
f"{FIRMWARE_INGEST_VETO_S:.0f} s or less (30 s is the tested value), "
"or rebuild the firmware with a matching max_age_s and update "
"validate.FIRMWARE_INGEST_VETO_S.")
# --- 5. a sign watchdog that can actually fire ---------------------------
# ⚠️ Strictly `>=`, matching the predicate exactly: watchdog.py tests
# `abs(commanded_w) > min_w`, and the arbiter holds `abs(commanded_w)` at or
# below max_w, so threshold == max_w is already unsatisfiable. Anything
# BELOW max_w is reachable and therefore fine - this refuses the disarmed
# case only, not "close to the rail".
sign_w = _number(opts, "sign_disagree_w", 300.0)
if sign_w is None:
problems.append(f"sign_disagree_w {opts.get('sign_disagree_w')!r} is not a number")
elif max_w is not None and max_w > 0 and sign_w >= max_w:
problems.append(
f"sign_disagree_w is {sign_w:.0f} W but max_w is {max_w:.0f} W, so "
"the SAFETY-02 sign-disagreement watchdog can never fire: the "
"arbiter never lets a command exceed max_w, and the watchdog needs "
f"a command over {sign_w:.0f} W. It would sit there reporting "
"'armed' on the status page while being incapable of tripping - the "
f"one runaway failure mode this system has actually observed. Lower "
f"sign_disagree_w below {max_w:.0f} W (300 W is the measured "
"default), or raise max_w.")
# --- 6. a maintenance charge the ceiling can actually accommodate --------
# ⚠️ Strictly `>`, matching the arbiter exactly. The shaping is
# `Claim.limit(hi=-charge_w)` against `supervised`'s `lo=-max_w`, so
# charge_w == max_w leaves the single reachable point -max_w and works;
# only ABOVE is `lo > hi`, arbiter clause 3, 0 W and a contradiction.
#
# Not scoped to maintenance_enabled, deliberately. The pair is
# contradictory whether or not the schedule is on, and scoping it would
# leave the trap armed for the one operator action - ticking
# maintenance_enabled - that cannot possibly be expected to change what a
# charge rate means.
# ⚠️ THE FALLBACK IS config.yaml's SHIPPED VALUE, and it has to be kept
# equal to it - that is the whole point of AC3. It is reachable only when a
# caller hands over a dict with the key missing (sim/inject.py, a test); the
# Supervisor always supplies every key from config.yaml, so on a real
# install the argument is always present.
#
# ⚠️ KNOWN MISMATCH, LEFT DELIBERATELY AND FLAGGED RATHER THAN FIXED HERE:
# `main.py` still falls back to 2500 in two places
# (`opts.get("maintenance_charge_w", 2500)`), as does maintenance.py's
# MaintConfig dataclass. So a dict with the key ABSENT is accepted by this
# rule at 2000 and then built by main.py at 2500 - the contradiction this
# rule exists to catch, in the one case it cannot see. It is unreachable on
# a Supervisor install and those files are another ticket's right now.
# THE REAL FIX is one source of truth for option defaults; until then the
# divergence is PINNED BY A CHECK rather than by this comment - see
# test_validate.py, "the KNOWN cross-file default divergence". It asserts
# the mismatch as it stands and goes red if EITHER side moves, including
# when somebody closes it in main.py, at which point this block and that
# check both get deleted.
charge_w = _number(opts, "maintenance_charge_w", 2000.0)
if charge_w is None:
problems.append(
f"maintenance_charge_w {opts.get('maintenance_charge_w')!r} is not a number")
elif max_w is not None and max_w > 0 and charge_w > max_w:
problems.append(
f"maintenance_charge_w is {charge_w:.0f} W but max_w is "
f"{max_w:.0f} W, so a maintenance charge in a cheap window can "
"never happen: the shaping asks the arbiter for at most "
f"{-charge_w:.0f} W while the supervised limit allows no less than "
f"{-max_w:.0f} W, which is a contradiction it resolves to 0 W - "
"THE CEILING WINS, and what you would see is an ARBITER "
"CONTRADICTION line that reads like a bug rather than like these "
f"two numbers. Lower maintenance_charge_w to {max_w:.0f} W or less, "
f"or raise max_w to at least {charge_w:.0f} W.")
# --- warnings: real, but not worth refusing over -------------------------
integ = opts.get("integrator_max_w")
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
if integ_w is not None and max_w is not None and integ_w > max_w:
_LOG.warning(
"integrator_max_w %.0f W is above max_w %.0f W. Not refused - the "
"arbiter still bounds the wire to +-max_w - but the only thing the "
"extra headroom buys is more wrong-direction power to unwind after "
"saturation. 0 (follow max_w) is the recommended value.",
integ_w, max_w)
# ⚠️ THE SIBLING OF RULE 6, AND NOT THE SAME CASE - see the docstring. The
# drain phase OWNS the actuator (`Claim.set` at P_MAINTENANCE), and a SET is
# clamped by the limits above it rather than contradicted by them. So this
# drains at max_w instead of the configured rate, the arbiter says so in
# words on the status page every cycle, and the cycle still completes -
# slower, and eating into maintenance.DRAIN_TIMEOUT_MIN. Loud and it moves
# energy, so it is neither (a) nor (b): warned, not refused.
disch_w = _number(opts, "maintenance_discharge_w", 2000.0)
if disch_w is not None and max_w is not None and max_w > 0 and disch_w > max_w:
_LOG.warning(
"maintenance_discharge_w %.0f W is above max_w %.0f W. Not refused - "
"the drain phase SETS the setpoint and the arbiter clamps it to "
"%.0f W and names the clamp ('limited by supervised(max_w)'), so "
"nothing is silent and the cycle still completes. But it drains at "
"%.0f W, not the %.0f W you configured, and the drain phase has a "
"720 min timeout. Lower it to %.0f W or raise max_w to remove the "
"surprise.",
disch_w, max_w, max_w, max_w, disch_w, max_w)
return problems
def _number(opts: dict, key, default):
raw = opts.get(key, default)
if raw is None or raw == "":
return default
try:
return float(raw)
except (TypeError, ValueError):
return None
def refuse(problems: list[str]) -> None:
"""Log a refusal an operator can tell apart from a crash. Does not raise.
⚠️ THE POINT OF THE BANNER. "You configured this wrong" must not read like
"it broke". A Python traceback in an add-on log means the same thing to most
operators as a segfault - file a bug - whereas this block names the keys,
names the fix, and says in words that nothing is broken. main.py catches
ConfigRefused and exits 78 (sysexits EX_CONFIG), so no traceback is printed
at all and even the exit status distinguishes the two.
"""
_LOG.error("=" * 72)
_LOG.error("REFUSING TO START: the add-on configuration is not usable.")
_LOG.error("This is a CONFIGURATION problem, not a crash. Nothing is broken;")
_LOG.error("the add-on will start as soon as the settings below are fixed.")
_LOG.error("Fix them in Settings > Add-ons > GoodWe RS485 Controller >")
_LOG.error("Configuration, then start the add-on again.")
_LOG.error("-" * 72)
for i, problem in enumerate(problems, 1):
_LOG.error(" %d. %s", i, problem)
_LOG.error("=" * 72)
+354
View File
@@ -0,0 +1,354 @@
"""SAFETY-02 - the sign-disagreement watchdog.
WHAT IT CATCHES, in one sentence: a grid-following loop that is pushing power in
the wrong direction, which every other guard in this system is blind to.
The stale-input watchdog (SAFETY-01) asks "is the meter still talking?". The
saturation freeze asks "can the inverter follow?". The output clamp asks "is the
number too big?". A loop can pass all three and still be charging the battery
out of the grid while the house imports - the meter is fresh, the inverter is
tracking beautifully, and the magnitude is inside the rating. The only thing
that separates that from healthy operation is the SIGN.
⚠️ THIS IS NOT A HYPOTHETICAL. On 2026-08-20 the vendor controller (Illusmart)
did exactly this four times in one day (NOTES.md §4.7). Both captures of that
bus are committed - `sim/scenarios/bus-2026-08-20.log.gz` and the healthy
`bus-2026-08-23.log.gz` in the infra repo - and `sim/replay_sign.py` drives this
module over both of them. Every number in this file was measured on those two
days, not chosen:
day samples gated in sign agreement
2026-08-23 4 212 / 17 280 93.4 % (healthy)
2026-08-20 7 182 / 17 280 56.4 % (the whole fault day)
cluster A 15:26-16:43 0.3 %
cluster B 17:11-18:28 0.9 %
cluster C 20:01-20:31 10.5 %
cluster D 20:55-21:11 0.0 %
⚠️ THOSE AGREEMENT FIGURES ARE THE WEAKEST EVIDENCE ON THIS PAGE, and an earlier
version of this comment leaned on them as though they were the strongest. The
clusters are found by looking for sustained opposed samples, so measuring "how
opposed is this cluster" over them is close to a tautology - and "the healthy day
contains no such cluster" is the same sentence as "the healthy day produces no
trip", not independent corroboration of it.
What actually carries the argument is two things neither the detector nor the
clustering assumes:
1. The RUN-LENGTH DISTRIBUTION. The longest unbroken opposed run on the healthy
day is 30 s. On the fault day there are 18 runs over 180 s and the longest is
1750 s. Nothing about that gap was chosen - it is what the two days measure.
2. The clusters land where a human independently wrote down onsets. NOTES.md
§4.7 records 15:01, 16:56, 19:57 and 20:23 from watching it happen, before
any of this existed, and cluster D coincides with the separately documented
inverter-off runaway of §4.7 item 2.
Be precise about (2), because the convenient overstatement is available and wrong:
the clustering does NOT reproduce four episodes. It yields THREE clusters over the
four documented onsets - C spans both 19:57 and 20:23 - plus a fourth for §4.7
item 2, which is not one of the four. Every trip does fall inside a documented
window, which is the claim worth making.
------------------------------------------------------------------------------
WHY IT LIVES HERE AND NOT IN THE FIRMWARE OR THE WITNESS
Three vantage points see three different things. The firmware knows what it
WROTE, the witness Pi knows what was ON THE WIRE and whether the inverter ACKed
it, and the add-on knows what it INTENDED and holds the authoritative meter.
This check is not command-versus-wire; it is command-versus-physics. It needs
the emitted setpoint and the P1 net figure in the same place, and it needs the
authority to command zero when they fight:
- the witness is read-only by charter and cannot command anything, so it could
raise the alarm but never take the trip action the AC requires;
- the firmware has the wire but not the meter. §5.1 makes P1 the only
authoritative grid figure and the board only ever receives its AGE
(`sensor.goodwe_p1_sample_age`), never its value. Putting the check there
would mean shipping the meter to the ESP32 for no other reason, and it would
be C++ per install rather than one generic guard;
- the add-on has both halves already, plus an arbiter that can outrank every
strategy with a P_SAFETY claim.
The cost of standing here is real and worth stating: this watchdog compares what
we MEANT to put on the wire against the meter. If the firmware or the driver
inverts the sign on the way out, the add-on's own view still agrees with itself
and this check stays silent. That gap is a wire-versus-intent problem and it
belongs to the witness, not here.
------------------------------------------------------------------------------
WHAT "DISAGREEMENT" MEANS, PRECISELY
disagree = following
and commanded_w * grid_w < 0
and abs(commanded_w) > min_w
and abs(grid_w) > min_w
Four gates, and each one exists to exclude a specific thing that is NOT a fault:
1. `following`. ⚠️ THE GATE THAT IS EASIEST TO FORGET AND MOST EXPENSIVE TO
OMIT. Sign agreement is a property of a GRID-FOLLOWING loop. It is not
expected of a strategy that deliberately commands against the meter -
maintenance is exactly that. A maintenance grid charge of 1500 W into a house
drawing 500 W puts +2000 W on the meter against a -1500 W command: opposed,
both far over any sane threshold, and sustained for HOURS. Armed
unconditionally this watchdog would trip on every single maintenance cycle,
which is not a tuning problem, it is the wrong question being asked. So the
caller says whether the grid-following loop actually won the arbitration this
cycle, and the timer only accumulates when it did.
⚠️ 1500 W, NOT THE DEFAULT 2500 W, AND THE REASON IS NOT COSMETIC. At the
shipped defaults `maintenance_charge_w` is 2500 and `max_w` is 2000, so the
cheap-window claim is `hi = -2500` against a supervised `lo = -2000`: lo > hi,
which arbiter.py resolves as a CONTRADICTION and 0 W, not as a -2500 W charge.
The example above is written at 1500 W because that is a combination the
schema and the arbiter both actually produce. (The contradiction at the
defaults is a real pre-existing bug - a default maintenance charge silently
never happens in a cheap window - but it is maintenance's, not this module's,
and it is filed separately. Do not "fix" it here.)
2. The strict `< 0` product. "Opposed" and "neither side is zero" in one
expression.
3. The 300 W magnitude gate ON BOTH SIDES. Near zero the sign is noise, and near
zero is where a healthy loop LIVES - the deadband holds the command still
while the meter wanders either side of `target_grid_w`. On the healthy day
only 4 212 of 17 280 samples (24 %) are even gated in; the other 76 % are the
converged band where sign carries no information. This is also why the
deadband cannot produce a false trip: inside it the meter is by definition
under 300 W.
4. The 180 s continuity requirement. This is what excludes the legitimate
transient. A load step reverses the meter's sign instantly while the command
is still where the last cycle left it; slew limiting then needs a few cycles
to cross over. Measured on the healthy day, the LONGEST such crossing is 30 s
- and that is with a vendor controller far cruder than ours. 180 s is six
times that. It is not a fitted threshold: at 60 s the healthy day still
produces zero trips, and at 300 s the fault day still produces 13.
⚠️ A BATTERY THAT REFUSES A COMMAND CANNOT TRIP THIS, and that is structural
rather than lucky. At SoC 10 % in Standby, a 1350 W discharge command into a
1350 W import is DECLINED: the battery does nothing, so the meter stays at
+1350 W and the command stays at +1350 W. Same sign. Agreement. A refusal leaves
the meter where it was; only the inverter ACTING moves it, and acting in the
commanded direction moves it toward zero, not through it. The failure mode this
check keys on is the opposite of a refusal - it is the inverter obediently doing
a wrong thing.
⚠️ A FROZEN METER cannot trip it either, for the same reason read the other way:
a stuck reading of +800 W makes the loop command discharge and keep commanding
discharge. Command and meter converge on AGREEING. Freezes are SAFETY-12's and
SAFETY-01's problem, and this watchdog neither helps nor hinders there.
⚠️ ALL OF THAT DEPENDS ON ONE PROPERTY OF THE CONTROL LAW, so it is an invariant
and not a happy accident: the saturation freeze in control.py must keep letting
the command FALL, CROSS ZERO AND REVERSE - "may not wind further in the direction
it is already pushing", not "only corrections that shrink |i_w|". control.py
records the shrink-only encoding as tried and rejected because it pins the command
at its last value indefinitely; a pinned command against a meter that has moved on
is precisely a sustained sign disagreement, so under that encoding this watchdog
WOULD false-trip on a plain load step. If anyone ever revisits that freeze, this
module's no-false-positive argument is downstream of the answer.
------------------------------------------------------------------------------
WHAT IT DOES NOT CATCH
An inverter that ACTS opposite to what it was told. Tell it to discharge 2000 W
and have it charge instead, and the meter moves FURTHER the way it was already
going - so the command and the meter agree, all the way into the rail. This
watchdog compares the loop's output direction against the input state it was
regulating; it is blind to the plant lying about which way it went. That is the
saturation freeze's question (|command - the battery's actual power| > 500 W,
NOTES.md §4.7 row 4), and the two checks are complementary rather than
overlapping. Neither substitutes for the other.
Nor does it see a sign inversion introduced DOWNSTREAM of this add-on - in the
firmware, on the wire, or in a future driver. Our view stays self-consistent and
this stays silent. That is a wire-versus-intent problem and it belongs to the
witness, which is the only vantage point that sees both.
------------------------------------------------------------------------------
STATE, TRIP AND LATCH
One timestamp, not a sample counter. The cycle rate is not fixed - a meter
arrival, or `cycle_floor_s` elapsing, whichever comes first - so N samples is a
different wall-clock window on every path, and the AC is written in minutes.
The latch is not optional and not a nicety. Commanding 0 W removes the command
side of the comparison (|0| is not > 300), so the disagreement disappears the
instant the trip works. Un-latched, this watchdog would trip, clear itself, and
hand the actuator straight back to the loop that was driving the wrong way -
three minutes later, forever. `tripped` therefore stays true until an operator
`reset()`s it by starting control again, which is a deliberate human act after
looking at why.
⚠️ AND THE LATCH HAS TO OUTLIVE THE PROCESS. Held only in memory it is not a
latch at all - a container restart clears it and the add-on comes back armed,
into the same fault, unattended. Worse than merely losing state: "restart the
add-on" is the first thing an operator confronted with a FAILSAFE banner and a
0 W inverter will try, and under a supervisor that restarts a crashed add-on it
is a loop of three-minute wrong-direction bursts. `tripped` and `reason` are
therefore constructor arguments, restored from `Store` in `Controller.__init__`
and written back the moment the trip happens. See store.py.
"""
from dataclasses import dataclass
from datetime import datetime
@dataclass(frozen=True)
class SignWatchdogConfig:
"""Defaults, not constants - config.yaml carries both (SAFETY-02 AC 5)."""
min_w: float = 300.0
hold_s: float = 180.0
def disagrees(commanded_w, grid_w, following: bool,
cfg: SignWatchdogConfig) -> bool:
"""The predicate, and the ONLY place it is written down.
⚠️ Public because `sim/replay_sign.py` needs it too - to describe episodes, to
measure agreement, to sweep the clock-skew guard - and it had reimplemented it
inline. Two copies of a safety predicate is one copy plus a future
disagreement about what the check means, and the copy that drifts is always
the one in the harness that grades it.
"""
return (following
and commanded_w is not None and grid_w is not None
and commanded_w * grid_w < 0
and abs(commanded_w) > cfg.min_w
and abs(grid_w) > cfg.min_w)
def loop_is_following(resolution, loop_asked) -> bool:
"""Did the grid-following loop actually choose the number going on the wire?
Gate 1 of the predicate above, and it lives here rather than inline in
`cycle()` for the reason `disagrees()` does: the test suite has to be able to
assert on THE SHIPPED EXPRESSION, not on a transcription of it that drifts
apart from it in silence.
⚠️ IT WAS A TRANSCRIPTION, AND THAT WAS MEASURED, NOT FEARED. The P_PEAK case
in test_watchdog.py exists to make whoever lands peak shaving come here and
change an expectation. With the expression copied into the test it did not do
that: editing the shipped gate alone to `winner in ("loop", "peak")` left every
suite green while the watchdog went blind for the whole of every peak event.
One definition, two callers, and that test now bites.
`resolution` the arbiter's Resolution. Duck-typed on `.winner` and
`.target_w` so this module still imports nothing from arbiter.
`loop_asked` what the grid-following loop claimed this cycle, or None if it
did not claim at all.
"The loop won" is NOT the question, and the difference is a whole class of
false trip. A LIMIT claim can survive the loop winning and still replace its
number: maintenance's cheap-window shaping is `hi = -maintenance_charge_w`, so
at 1500 W the loop can ask for +500 W of discharge, win the arbitration, and
have the emitted value come out at -1500 W of grid charge. Winner says "loop";
the wire carries maintenance's intent.
So the test is on the NUMBER: the loop is following only while the emitted
value points the way the loop asked AND is no larger than it asked - limits
reduced it, they did not redirect it. The magnitude half is load-bearing on
its own, because a `lo` limit can raise magnitude without flipping sign, and
that is not the loop following either. Zero on either side falls out as
not-following, which costs nothing: a 0 W command cannot be a
wrong-direction command.
⚠️ FORWARD HAZARD, and the claim block in cycle() already anticipates it.
`winner == "loop"` disarms the watchdog under ANY higher-priority SET claim.
Today only maintenance and the safety stops emit one and neither follows the
meter, so the gate costs nothing. A peak-shaving strategy claiming SET at
P_PEAK **is** grid-following in sign, and the moment it lands this goes blind
for the duration of every peak event. Widening it means asking "does the
winning strategy follow the meter", not adding another name to a comparison.
"""
return (resolution.winner == "loop" and loop_asked is not None
and resolution.target_w * loop_asked > 0
and abs(resolution.target_w) <= abs(loop_asked))
class SignWatchdog:
"""One instance per actuator, evaluated once per control cycle.
⚠️ NOT SHARED ACROSS CADENCES. `disagree_since` is a wall-clock start time,
so driving one instance from two loops at two rates would have each one
resetting the other's window. If a fast on-device path ever wants this
check, it gets its own instance - the same exactly-one-writer discipline the
arbiter applies to the actuator, applied to the detector's own state.
"""
def __init__(self, cfg: SignWatchdogConfig | None = None, *,
tripped: bool = False, reason: str = ""):
self.cfg = cfg or SignWatchdogConfig()
self.disagree_since: datetime | None = None
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED. A latch that lives only in
# memory is not a latch: a container restart clears it, and the add-on
# comes back armed, into the same fault, with no operator involved. See
# store.py's note on `sign_tripped` for the measured behaviour.
self.tripped = bool(tripped)
self.reason = reason if self.tripped else ""
# -- the whole check, and it is a pure function of its arguments ----------
def evaluate(self, commanded_w, grid_w, following: bool,
now: datetime) -> bool:
"""Advance the detector one cycle. Returns True while tripped.
`commanded_w` the EMITTED setpoint - what is standing on the wire now,
after deadband, slew, quantisation and the arbiter. Not
the optimizer's raw wish: the wire carries the emitted
value, so anything else can disagree with the meter for a
reason that is not a fault.
`grid_w` net P1, + = importing. None when the meter is stale or
missing, which CLEARS the timer rather than accumulating
- a frozen figure held against a moving command would
otherwise manufacture a disagreement in about three
minutes, on top of SAFETY-01 having already commanded
zero for the same cause.
`following` did the grid-following loop actually win this cycle? See
gate 1 in the module docstring.
`now` the caller's clock, so this stays testable and replayable.
"""
if self.tripped:
# Latched. Do not re-evaluate: the trip removed the evidence.
return True
cfg = self.cfg
if not disagrees(commanded_w, grid_w, following, cfg):
self.disagree_since = None
return False
if self.disagree_since is None:
self.disagree_since = now
return False
held = (now - self.disagree_since).total_seconds()
if held < cfg.hold_s:
return False
self.tripped = True
self.reason = (
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against a meter "
f"reading {grid_w:+.0f} W for {held:.0f} s continuously "
f"(limits: both over {cfg.min_w:.0f} W, held over {cfg.hold_s:.0f} s)"
)
return True
def held_s(self, now: datetime) -> float:
"""How long the current disagreement has been standing, for the UI.
⚠️ Takes the clock rather than reading one. It was a property calling
`datetime.now()`, which quietly broke the property this module's header
advertises - every other observable here is a pure function of what it
was handed - and an unclocked function is one nothing can test, which is
exactly what happened to it.
"""
if self.disagree_since is None:
return 0.0
return (now - self.disagree_since).total_seconds()
def reset(self) -> None:
self.disagree_since = None
self.tripped = False
self.reason = ""
+46 -3
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.3.0"
version: "0.5.1"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
@@ -90,14 +90,51 @@ options:
integrator_max_w: 0
heartbeat_s: 10
stale_input_s: 15
cycle_floor_s: 15
auto_start: false
# --- SAFETY-02 sign-disagreement watchdog ----------------------------------
# Trips when the emitted setpoint and the P1 net figure point OPPOSITE ways,
# both over sign_disagree_w, continuously for sign_disagree_s. Action: 0 W and
# a failsafe that latches until an operator starts control again.
#
# Both defaults are measured, not chosen. On the captured healthy day
# (2026-08-23) the longest legitimate opposed run - a load step the loop has
# not caught up with - is 30 s, and sign agreement over the gated samples is
# 93.4 %. On the captured fault day (2026-08-20) the clusters run 0.0-10.5 %
# agreement with opposed runs up to 1752 s. 300 W / 180 s sits in the middle of
# a very wide gap: at 60 s the healthy day still trips nothing, at 300 s the
# fault day still trips 13 times. There is no reason to move either number
# without a capture that says so. They are options because the AC says
# thresholds are defaults rather than constants - not because they are knobs
# anyone is expected to turn.
#
# ⚠️ sign_disagree_w must stay BELOW max_w or the watchdog can never fire (the
# arbiter bounds the command to +-max_w). validate.py refuses that config.
sign_disagree_w: 300
sign_disagree_s: 180
# --- maintenance -----------------------------------------------------------
maintenance_enabled: false
maintenance_interval_days: 28
maintenance_start_hour: 10
maintenance_discharge_w: 2500
maintenance_charge_w: 2500
# ⚠️ BOTH MUST STAY AT OR BELOW max_w, and that is why they are 2000 rather
# than the 2500 they shipped as. The cheap-window charge shaping asks the
# arbiter for `hi = -maintenance_charge_w` against the supervised `lo =
# -max_w`: above the ceiling that is `lo > hi`, a contradiction resolved to
# 0 W, so maintenance would SILENTLY NEVER CHARGE in a cheap window on a
# default install. validate.py refuses that config (rule 6), so these
# defaults had to become self-consistent with the max_w above rather than
# ship a configuration the validator rejects.
#
# The discharge side is clamped rather than contradicted - it drains at max_w
# and the arbiter says so - so it is only warned about; it is 2000 here for
# symmetry and to keep the shipped config warning-free.
#
# Raising max_w (the live reference install runs 5000) is what unlocks a
# faster maintenance cycle. Raise max_w FIRST, then these.
maintenance_discharge_w: 2000
maintenance_charge_w: 2000
maintenance_soc_floor: 11
maintenance_soc_target: 99
maintenance_hold_min: 120
@@ -151,8 +188,14 @@ schema:
integrator_max_w: int(0,15000)
heartbeat_s: int(2,25)
stale_input_s: int(5,120)
cycle_floor_s: int(5,60)
auto_start: bool
# No "off" value, deliberately: this is a P0 safety check and the schema is
# not the place to make disarming it a supported configuration.
sign_disagree_w: int(50,5000)
sign_disagree_s: int(30,1800)
maintenance_enabled: bool
maintenance_interval_days: int(1,90)
maintenance_start_hour: int(0,23)
+213
View File
@@ -0,0 +1,213 @@
"""Runnable check for the control loop's cadence. `python3 test_loop.py`
SAFETY-12: the loop must evaluate on a clock as well as on a change. Before the
fix, `run_control()` ran `cycle()` only when the meter value differed from the
previous poll, so a meter that repeats a value ran NO control cycles while the
heartbeat kept re-emitting the last command - measured on the rig during TEL-05
as 70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
⚠️ THIS TEST TAKES ~95 SECONDS OF WALL CLOCK (measured 93 s), on purpose, and
that figure is the only thing standing between it and a future developer who
decides a slow test is a broken one. The thing under test is a wall-clock floor
inside a loop that sleeps 1 s; mocking the clock would leave the assertion
testing the mock. It drives the real `run_control()` and counts what actually
happened. Eight runs of the real loop is what the eight scenarios cost.
⚠️ If you shorten the windows, re-measure and update this number and the one in
HANDOVER.md. An understated runtime reads as a hang.
`cycle_floor_s` is read from options with no lower bound in code, so a huge
value reproduces the pre-fix behaviour exactly. Every claim below is therefore
an A/B on one binary, not a comparison against a remembered old one.
"""
import asyncio
import sys
import time
from app.main import Controller
fails = []
NEVER = 1e9 # cycle_floor_s so large the floor can never elapse: pre-fix
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
class FakeHass:
"""A scripted meter and a plant that tracks the command instantly."""
def __init__(self, meter, soc_dies_at=None):
self.meter = meter
self.soc_dies_at = soc_dies_at
self.batt = 0.0
self.writes = []
self.t0 = time.monotonic()
async def limits(self, entity):
return (-5000.0, 5000.0, 1.0)
async def number(self, entity, invert=False):
now = time.monotonic() - self.t0
if entity == "sensor.grid":
return self.meter(now)
if entity == "sensor.batt":
return self.batt
if entity == "sensor.soc":
if self.soc_dies_at is not None and now >= self.soc_dies_at:
return None
return 50.0
return None
async def set_number(self, entity, value):
self.writes.append(float(value))
self.batt = float(value)
return True
class _Store:
data = {}
def set(self, *a):
pass
class _Pub:
enabled = False
def publish(self, *a, **k):
pass
def close(self):
pass
BASE = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": 0.6, "slew_w": 1000,
"deadband_w": 15, "target_grid_w": -10, "step_w": 10,
"heartbeat_s": 10, "stale_input_s": 15}
def drive(meter, floor, seconds, soc_dies_at=None, **over):
"""Run the real control loop for `seconds`; return (cycle times, writes)."""
async def go():
hass = FakeHass(meter, soc_dies_at)
c = Controller(dict(BASE, cycle_floor_s=floor, **over), hass, _Store(),
_Pub(), stop=asyncio.Event())
c.auto = True
stamps = []
real = c.cycle
async def counted():
stamps.append(time.monotonic() - hass.t0)
await real()
c.cycle = counted
task = asyncio.create_task(c.run_control())
await asyncio.sleep(seconds)
c.stopping = True
await asyncio.wait_for(task, timeout=10)
return stamps, hass.writes, c.target, c.reason
return asyncio.run(go())
def worst_gap(stamps, seconds):
"""Longest stretch with no cycle, including the tail after the last one."""
edges = [0.0] + list(stamps) + [seconds]
return max(b - a for a, b in zip(edges, edges[1:]))
# --------------------------------------------------------------------------- #
print("a meter that repeats the same value")
FLAT = lambda t: 350.0 # noqa: E731
FLOOR, SECONDS = 3.0, 12.0
pre_stamps, pre_writes, _, _ = drive(FLAT, NEVER, SECONDS)
# The defect itself, demonstrated rather than described: one cycle at startup
# and then nothing for the rest of the window, while writes keep happening.
check("pre-fix: a constant meter runs exactly one cycle, at startup",
len(pre_stamps) == 1)
check("...while the heartbeat keeps writing anyway, so nothing looks wrong",
len(pre_writes) >= 2)
post_stamps, post_writes, _, _ = drive(FLAT, FLOOR, SECONDS)
check("post-fix: the same constant meter runs cycles throughout",
len(post_stamps) >= int(SECONDS / FLOOR) - 1)
# The actual acceptance criterion: a BOUND on the gap, not a count.
gap = worst_gap(post_stamps, SECONDS)
check(f"...with no gap longer than the floor ({gap:.1f}s <= {FLOOR + 1.5:.1f}s)",
gap <= FLOOR + 1.5)
check("...and the loop actually corrected, instead of holding a stale command",
len(post_writes) > len(pre_writes))
# --------------------------------------------------------------------------- #
print("a meter that changes normally - nothing may move")
# ⚠️ THE REGRESSION GUARD, and the more important half. The floor is a deadline
# on the gap between cycles, reset by every cycle whichever trigger fired - not
# a second scheduler. On a healthy meter it must never elapse, so the cycle
# count, the write count and the commanded values must be IDENTICAL either side
# of the fix. Anything else is a new write cadence, which SAFETY-12 forbids:
# the deadband, step_w and the 10 s force-write decide what reaches the wire,
# and this change is only allowed to alter when the loop thinks.
STEPS = [0.0, 300.0, 850.0, -400.0, 120.0, -900.0, 60.0]
LIVE = lambda t: STEPS[int(t // 2) % len(STEPS)] # noqa: E731
a_stamps, a_writes, _, _ = drive(LIVE, NEVER, 12.0)
b_stamps, b_writes, _, _ = drive(LIVE, FLOOR, 12.0)
check("a changing meter runs the same number of cycles as before the fix",
len(a_stamps) == len(b_stamps))
check("...commanding exactly the same sequence of values", a_writes == b_writes)
# --------------------------------------------------------------------------- #
print("a meter parked at the target - the converged operating point")
# The case TEL-05 warned about: at the converged target the power figure
# legitimately repeats for minutes. The loop must still run, and must still
# write nothing but the heartbeat, because the deadband - not the arrival
# trigger - is what holds the command still.
AT_TARGET = lambda t: -10.0 # noqa: E731
c_stamps, c_writes, _, _ = drive(AT_TARGET, NEVER, 12.0)
d_stamps, d_writes, _, _ = drive(AT_TARGET, FLOOR, 12.0)
check("the loop evaluates at the converged point too", len(d_stamps) > len(c_stamps))
check("...and the deadband still holds the command, so writes are unchanged",
d_writes == c_writes)
# --------------------------------------------------------------------------- #
print("an input dies while the meter repeats - the safety claim must still fire")
# ⚠️ THE STRONGEST PROPERTY IN SAFETY-12, and the one that makes it a safety fix
# rather than a latency fix. The `inputs missing -> 0 W` claim lives INSIDE
# cycle() (main.py, the stale_input_s branch and the P_SAFETY claim below it).
# Pre-fix, on a meter whose value happened to repeat, cycle() was never called
# again - so that claim could not fire AT ALL. The controller held its last
# command through an input outage of unbounded length with the status line still
# reading "loop -> N W".
#
# Layer 1 does not cover this either on a `meter_source: off` install: no P1 age
# sensor is published (see Controller.publish), so the firmware has nothing to
# veto on, and the heartbeat keeps its watchdog fed the whole time.
#
# stale_input_s is shortened to 3 s here so the outage resolves inside a test
# rather than inside a quarter of a minute. The mechanism is the default one.
c2_stamps, c2_writes, pre_target, pre_reason = drive(
FLAT, NEVER, 10.0, soc_dies_at=4.0, stale_input_s=3)
check("pre-fix: a dead input during a constant meter never reaches the safety claim",
pre_target != 0.0 and "safety" not in pre_reason)
check(f"...so it holds its last command instead ({pre_target:g} W, {pre_reason!r})",
pre_target == 220.0)
d2_stamps, d2_writes, post_target, post_reason = drive(
FLAT, FLOOR, 10.0, soc_dies_at=4.0, stale_input_s=3)
check("post-fix: the same outage commands 0 W", post_target == 0.0)
check(f"...through the safety claim, not by accident ({post_reason!r})",
"safety" in post_reason)
check("...and the 0 W actually reached the device", 0.0 in d2_writes)
# --------------------------------------------------------------------------- #
print()
if fails:
print(f"{len(fails)} FAILED: " + "; ".join(fails))
sys.exit(1)
print("all checks passed")
+16 -5
View File
@@ -1346,6 +1346,17 @@ check("with P1 on the age sensor IS announced",
from app.main import Controller # noqa: E402
def _never():
"""A stop Event these publish-only tests never set.
`stop` is a REQUIRED keyword argument (CFG-01): a Controller that cannot
stop itself used to be the default one, and on the late-refusal path that
meant a live process with no control loop and no exit. These cases only call
publish(), so any Event will do - but they may not skip it.
"""
return asyncio.Event()
class _Store:
data = {}
@@ -1368,14 +1379,14 @@ class _Pub:
pub_off = _Pub()
Controller({"meter_source": "off"}, None, _Store(), pub_off).publish()
Controller({"meter_source": "off"}, None, _Store(), pub_off, stop=_never()).publish()
check("with P1 off, p1_age is absent from the published payload",
"p1_age" not in pub_off.last)
check("...while the normal status keys are still published",
"setpoint" in pub_off.last and "grid" in pub_off.last)
pub_on = _Pub()
Controller({"meter_source": SOURCE_HA}, None, _Store(), pub_on).publish()
Controller({"meter_source": SOURCE_HA}, None, _Store(), pub_on, stop=_never()).publish()
check("with P1 on, p1_age is published", "p1_age" in pub_on.last)
check("...as a number, so has_state() becomes true only once we feed it",
isinstance(pub_on.last["p1_age"], float))
@@ -1384,14 +1395,14 @@ check("...as a number, so has_state() becomes true only once we feed it",
# age sensor is a hard prerequisite for the FW-01 flash, and it has to appear on
# the transport that can actually read the meter in this house.
pub_sig = _Pub()
Controller({"meter_source": SOURCE_HA_SIGNED}, None, _Store(), pub_sig).publish()
Controller({"meter_source": SOURCE_HA_SIGNED}, None, _Store(), pub_sig, stop=_never()).publish()
check("with ha_signed selected, p1_age is published too",
"p1_age" in pub_sig.last and isinstance(pub_sig.last["p1_age"], float))
# ⚠️ And on homewizard_local, where it is the one age FW-01 may actually
# threshold - every other transport's age measures when the VALUE changed.
pub_hw = _Pub()
Controller({"meter_source": SOURCE_HOMEWIZARD}, None, _Store(), pub_hw).publish()
Controller({"meter_source": SOURCE_HOMEWIZARD}, None, _Store(), pub_hw, stop=_never()).publish()
check("with homewizard_local selected, p1_age is published",
"p1_age" in pub_hw.last and isinstance(pub_hw.last["p1_age"], float))
@@ -1421,7 +1432,7 @@ def p1_rows(ctl):
def _fed(source):
ctl = Controller({"meter_source": source}, None, _Store(), _Pub())
ctl = Controller({"meter_source": source}, None, _Store(), _Pub(), stop=_never())
ctl.p1.submit(make_sample(source, 350.0, 0.0, phases=1,
ingest_mono=time.monotonic()))
return ctl
+489
View File
@@ -0,0 +1,489 @@
"""Runnable check for the startup gate. `python3 test_validate.py`
Two halves, and the second is the one that matters. The first asserts that the
three refusable configurations are refused. The second asserts that everything
on validate.py's "deliberately not refused" list still STARTS - because the way
a validator dies is not by missing a fault, it is by refusing something harmless
until somebody deletes the call.
"""
import asyncio
import sys
from app.validate import (
ACTUATOR_WRITE_KEYS, FIRMWARE_INGEST_VETO_S, ConfigRefused, refuse,
validate_startup_config,
)
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def base(**over):
"""A configuration that must start. Everything else is this, spoilt."""
# ⚠️ The maintenance rates are named EXPLICITLY, at the values config.yaml
# ships (MAINT-04). They are not decoration: with the key absent, rule 6
# falls back to main.py's 2500 W, which against this 2000 W ceiling is a
# genuine refusal - so a base() without them would be a config that does
# not start, and every check below would be measuring the wrong thing.
o = {"setpoint_entity": "number.goodwe_setpoint", "max_w": 2000,
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off",
"maintenance_charge_w": 2000, "maintenance_discharge_w": 2000}
o.update(over)
return o
def why(problems, needle):
return any(needle in p for p in problems)
# --------------------------------------------------------------------------- #
print("the baseline must start, or nothing below means anything")
check("a good config with a 5000 W device is accepted",
validate_startup_config(base(), -5000, 5000) == [])
check("...and with no device reachable yet, too",
validate_startup_config(base(), None, None) == [])
# --------------------------------------------------------------------------- #
print("1. max_w against the device's own rating")
# ⚠️ THE ORIGINAL BUG. main.py used to log 'the device wins' and run anyway,
# with write_setpoint() clamping, so the configured ceiling was never the real
# one and the only evidence had scrolled off the log.
p = validate_startup_config(base(max_w=8000), -5000, 5000)
check("max_w above the device maximum is refused", len(p) == 1)
check("...and the message names the configured value", why(p, "8000"))
check("...and the device's value", why(p, "5000"))
check("...and says which one wins", why(p, "THE DEVICE WINS"))
check("max_w exactly at the device maximum is fine",
validate_startup_config(base(max_w=5000), -5000, 5000) == [])
check("max_w under it is fine",
validate_startup_config(base(max_w=2000), -5000, 5000) == [])
# The charge side is a separate rail and an asymmetric device is legal.
p = validate_startup_config(base(max_w=4000), -2500, 5000)
check("a max_w the device cannot take on the CHARGE side is refused too",
len(p) == 1 and why(p, "charge side"))
check("...naming the device's floor", why(p, "-2500"))
# ⚠️ Not guessed at: the entity may simply not have booted yet. run_control()
# re-runs this the moment the real rating arrives.
check("an unreachable device skips the range check rather than assuming",
validate_startup_config(base(max_w=8000), None, None) == [])
check("a non-numeric max_w is refused",
why(validate_startup_config(base(max_w="lots"), -5000, 5000), "not a number"))
# --------------------------------------------------------------------------- #
print("2. an actuator to write to")
# A controller with no actuator: write_setpoint() returns on the blank entity,
# so no rating is read, no heartbeat is sent, layer 1 pins the inverter at 0 W,
# and the add-on looks perfectly healthy the whole time.
for blank in ("", " ", None):
p = validate_startup_config(base(setpoint_entity=blank), None, None)
check(f"setpoint_entity {blank!r} is refused", len(p) == 1)
check("...and the message says why it is dangerous rather than untidy",
why(validate_startup_config(base(setpoint_entity=""), None, None),
"heartbeat"))
# specs §1.5: two writers on one actuator is not expressible in this schema.
check("there is exactly one way to reach the actuator",
ACTUATOR_WRITE_KEYS == ("setpoint_entity",))
# --------------------------------------------------------------------------- #
print("3. a meter that can never read")
# ⚠️ These predicates belong to p1.validate_meter_options(), which build_source()
# also uses. Asserted here to prove the gate actually consults it - one entry
# point, not two.
check("meter_source off asks nothing of the P1 keys",
validate_startup_config(base(meter_source="off"), -5000, 5000) == [])
check("homewizard_local with no p1_host is refused",
why(validate_startup_config(base(meter_source="homewizard_local"),
-5000, 5000), "p1_host"))
check("...and with a host it is accepted",
validate_startup_config(base(meter_source="homewizard_local",
p1_host="192.168.2.250"), -5000, 5000) == [])
check("a poll cadence at meter_max_age_s is refused at STARTUP, not just disabled",
why(validate_startup_config(base(meter_source="homewizard_local",
p1_host="m", meter_poll_s=30,
meter_max_age_s=30), -5000, 5000),
"meter_max_age_s"))
check("ha_signed with no p1_net_entity is refused",
why(validate_startup_config(base(meter_source="ha_signed"), -5000, 5000),
"p1_net_entity"))
check("a phase list disagreeing with meter_phases is refused",
why(validate_startup_config(base(meter_source="ha_signed",
p1_net_entity="sensor.n", meter_phases=3,
p1_phase_net_entities=["a", "b"]),
-5000, 5000), "phase-count"))
check("mqtt_p1 with no topic is refused",
why(validate_startup_config(base(meter_source="mqtt_p1"), -5000, 5000),
"meter_mqtt_topic"))
check("ha_dsmr with only half its entities is refused",
why(validate_startup_config(base(meter_source="ha_dsmr",
p1_import_entity="sensor.i"), -5000, 5000),
"p1_export_entity"))
check("a misspelt meter_source is refused rather than silently ignored",
why(validate_startup_config(base(meter_source="ha_signd"), -5000, 5000),
"is not one of"))
# --------------------------------------------------------------------------- #
print("4. meter_max_age_s against the firmware's compile-time veto")
# ⚠️ The schema allows int(5,300); the firmware's threshold is baked in at 30 s
# and wins silently. Same shape as the max_w case: a configured bound overridden
# by a lower layer, with nothing saying so.
hw = dict(meter_source="homewizard_local", p1_host="m")
p = validate_startup_config(base(**hw, meter_max_age_s=120), -5000, 5000)
check("a meter_max_age_s above the firmware veto is refused", len(p) == 1)
check("...naming the configured value", why(p, "120"))
check("...naming the firmware's value", why(p, "30"))
check("...and saying which one wins", why(p, "THE FIRMWARE WINS"))
check("the tested pair 30/30 is accepted",
validate_startup_config(base(**hw, meter_max_age_s=30), -5000, 5000) == [])
check("one second above it is refused",
validate_startup_config(base(**hw, meter_max_age_s=31), -5000, 5000) != [])
# Below the veto the add-on gives up FIRST, which is fail-safe and visible on
# its own status page. Only above is the silent case.
check("below the veto is fine - the add-on being stricter is not a conflict",
validate_startup_config(base(**hw, meter_max_age_s=10,
meter_poll_s=4), -5000, 5000) == [])
# ⚠️ Scope: meter_max_age_s is read by nothing but P1Ingest, and the veto keys
# off a sensor only published when ingestion runs. With the meter off it governs
# nothing, so refusing would be pure trivia.
check("with meter_source off the number governs nothing and is not refused",
validate_startup_config(base(meter_source="off", meter_max_age_s=300),
-5000, 5000) == [])
check("the constant is the firmware's, not a rounded guess",
FIRMWARE_INGEST_VETO_S == 30.0)
# --------------------------------------------------------------------------- #
print("6. a maintenance charge the ceiling can actually accommodate (MAINT-04)")
# ⚠️ THE SHIPPED BUG. config.yaml shipped max_w 2000 against
# maintenance_charge_w 2500, so the cheap-window shaping asked for hi=-2500
# against the supervised lo=-2000 - lo > hi, arbiter clause 3, 0 W. Maintenance
# silently never charged in a cheap window on a default install.
p = validate_startup_config(base(max_w=2000, maintenance_charge_w=2500),
-5000, 5000)
check("maintenance_charge_w above max_w is refused", len(p) == 1)
check("...and the message names the charge rate", why(p, "2500"))
check("...and the ceiling", why(p, "2000"))
check("...and says which one wins", why(p, "THE CEILING WINS"))
# ⚠️ Equality is REACHABLE, not a near miss: lo=-2000, hi=-2000 is the single
# point -2000 W. Refusing it would be exactly the trivia that gets a validator
# deleted, and it is the boundary the rule is written `>` for.
check("maintenance_charge_w exactly at max_w starts",
validate_startup_config(base(max_w=2000, maintenance_charge_w=2000),
-5000, 5000) == [])
check("below it starts",
validate_startup_config(base(max_w=2000, maintenance_charge_w=1500),
-5000, 5000) == [])
# Not scoped to maintenance_enabled: the pair is contradictory either way, and
# scoping would leave the trap armed for the one action - ticking the box - that
# cannot be expected to change what a charge rate means.
check("...and it is refused with maintenance_enabled off, as shipped",
why(validate_startup_config(
base(max_w=2000, maintenance_charge_w=2500,
maintenance_enabled=False), -5000, 5000), "THE CEILING WINS"))
# ⚠️ THE SIBLING, CHECKED RATHER THAN ASSUMED. The shaping is NOT symmetric:
# drain files Claim.set at P_MAINTENANCE and owns the actuator, so the ceiling
# CLAMPS it (+2000 W) instead of contradicting it, and the arbiter's explain()
# names the clamp every cycle. Loud, and it still moves energy - so warned, not
# refused. If someone later "fixes the asymmetry" by making this a refusal,
# this check goes red and they have to justify it.
check("maintenance_discharge_w above max_w WARNS but starts",
validate_startup_config(base(max_w=2000, maintenance_discharge_w=2500),
-5000, 5000) == [])
# The demonstration the rule is derived from, asserted rather than described.
from app.arbiter import ( # noqa: E402
Claim, P_LOOP, P_MAINTENANCE, P_MAINT_SHAPE, P_SAFETY, resolve,
)
def _charge(max_w, charge_w):
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-charge_w,
reason="cheap-window charge"),
Claim.set("loop", P_LOOP, 500.0, "grid")])
def _drain(max_w, disch_w):
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
Claim.set("maintenance", P_MAINTENANCE, disch_w, "drain"),
Claim.set("loop", P_LOOP, 500.0, "grid")])
r = _charge(2000, 2500)
check("arbiter: the refused pair really does emit 0 W",
r.target_w == 0.0 and r.contradiction)
r = _charge(2000, 2000)
check("arbiter: the permitted equality really does charge",
r.target_w == -2000.0 and not r.contradiction)
r = _charge(3000, 2500)
check("arbiter: raising max_w above the rate charges at the rate",
r.target_w == -2500.0 and not r.contradiction)
r = _drain(2000, 2500)
check("arbiter: the drain SET is clamped, not contradicted",
r.target_w == 2000.0 and not r.contradiction)
check("...and the clamp names itself, which is why it is not refused",
"supervised" in (r.bound_by or "") and "limited by" in r.explain())
# --------------------------------------------------------------------------- #
print("the SHIPPED defaults must pass the rule they are governed by (AC3)")
# ⚠️ Shipping a default the validator refuses would be worse than the bug it
# refuses. Read config.yaml itself rather than a transcription of it - a
# transcription is what lets the two drift apart silently. Regex, not PyYAML:
# the add-on image has no PyYAML (Dockerfile installs py3-aiohttp/py3-paho-mqtt
# only) and a check that skips on ImportError is not a check.
import os # noqa: E402
import re # noqa: E402
_CFG = os.path.join(os.path.dirname(os.path.abspath(__file__)), "config.yaml")
with open(_CFG, encoding="utf-8") as _fh:
_txt = _fh.read()
_shipped = {k: float(v) for k, v in re.findall(
r"^ (max_w|maintenance_charge_w|maintenance_discharge_w|sign_disagree_w): "
r"(-?\d+(?:\.\d+)?)\s*$", _txt, re.M)}
check("config.yaml really was read (all four defaults found)",
set(_shipped) == {"max_w", "maintenance_charge_w",
"maintenance_discharge_w", "sign_disagree_w"})
check(f"the shipped defaults are accepted {_shipped}",
validate_startup_config(base(**_shipped), -5000, 5000) == [])
check("...and the shipped charge rate is at or under the shipped ceiling",
_shipped["maintenance_charge_w"] <= _shipped["max_w"])
check("...and the shipped discharge rate too, so it warns about nothing",
_shipped["maintenance_discharge_w"] <= _shipped["max_w"])
# --------------------------------------------------------------------------- #
print("the KNOWN cross-file default divergence, pinned rather than commented")
# ⚠️ WHAT THIS GUARDS, AND WHY IT ASSERTS THE BUG RATHER THAN THE FIX.
# config.yaml and validate.py now default maintenance_charge_w to 2000, while
# main.py's two `opts.get(..., 2500)` fallbacks and MaintConfig's dataclass
# default still say 2500. So an options dict with the key ABSENT is ACCEPTED by
# rule 6 at 2000 and then built by main.py at 2500 - which is a contradiction:
#
# validate_startup_config -> [] (accepted)
# MaintConfig().charge_w -> 2500.0
# arbiter -> 0.0 W, contradiction=True
#
# That is the bug rule 6 exists to catch, passing rule 6. It is unreachable on a
# Supervisor install (every key is always supplied from config.yaml) but fully
# reachable from sim/inject.py and from tests - which is exactly where anyone
# debugging maintenance works.
#
# The fix is ONE SOURCE OF TRUTH for option defaults. That is a bigger change
# than this ticket and it lands in main.py, which another ticket is live in - so
# the divergence is RECORDED here instead of closed. The check therefore passes
# on the mismatch and FAILS when either side moves, in EITHER direction:
#
# - config.yaml moves -> FAIL: re-decide what the fallback should be
# - main.py is fixed to match -> FAIL: the divergence is gone, DELETE this
# check and the ⚠️ block in validate.py
#
# A comment cannot do that, and "a comment where a check belonged" is this
# repo's most repeated defect.
_APP = os.path.join(os.path.dirname(os.path.abspath(__file__)), "app")
def _read(*parts):
with open(os.path.join(*parts), encoding="utf-8") as fh:
return fh.read()
# Every literal fallback for this key in main.py, whatever the call shape.
_main_falls = [float(m) for m in re.findall(
r'\.get\(\s*"maintenance_charge_w"\s*,\s*(-?\d+(?:\.\d+)?)\s*\)',
_read(_APP, "main.py"))]
# ...and MaintConfig's own dataclass default, which is the one that bites when
# main.py is bypassed entirely (a Maintenance built straight from defaults).
_dc_falls = [float(m) for m in re.findall(
r"^\s*charge_w:\s*float\s*=\s*(-?\d+(?:\.\d+)?)\s*$",
_read(_APP, "maintenance.py"), re.M)]
check(f"main.py's fallbacks are still found and still 2500 {_main_falls}",
len(_main_falls) == 2 and set(_main_falls) == {2500.0})
check(f"MaintConfig's default is still found and still 2500 {_dc_falls}",
len(_dc_falls) == 1 and set(_dc_falls) == {2500.0})
check(f"...and config.yaml still ships 2000, so the divergence is UNCHANGED "
f"(shipped {_shipped['maintenance_charge_w']:.0f}, code 2500)",
_shipped["maintenance_charge_w"] == 2000.0)
# ⚠️ And the consequence itself, through the REAL code rather than through the
# numbers above - so that if someone "fixes" this by changing a literal without
# understanding it, the thing that goes red is the behaviour, not the transcript.
from app.maintenance import MaintConfig # noqa: E402
_absent = {k: v for k, v in base().items() if k != "maintenance_charge_w"}
_built = MaintConfig().charge_w
check("with the key ABSENT the validator accepts...",
validate_startup_config(_absent, -5000, 5000) == [])
check(f"...while the code would build {_built:.0f} W against a "
f"{_absent['max_w']:.0f} W ceiling...", _built > _absent["max_w"])
_r = _charge(_absent["max_w"], _built)
check("...which the arbiter resolves to 0 W as a contradiction - the hole, "
"asserted so it cannot widen unnoticed",
_r.target_w == 0.0 and _r.contradiction)
# --------------------------------------------------------------------------- #
print("max_w must be a positive magnitude")
# Schema-blocked on a real install, but validate_startup_config() is also
# sim/inject.py's entry point and can be handed any dict at all.
for bad in (0, -1, -2000):
p = validate_startup_config(base(max_w=bad), -5000, 5000)
check(f"max_w {bad} is refused", len(p) == 1 and why(p, "must be positive"))
check("...and the message explains it would read as a trip, not a mistake",
why(validate_startup_config(base(max_w=0), -5000, 5000), "contradiction"))
# ⚠️ SAFETY-02 changed what this case has to say, and the change is real rather
# than bookkeeping: with a 1 W ceiling the default 300 W sign-disagreement
# threshold is unreachable, so rule 5 refuses - correctly, because the watchdog
# would report itself armed while being incapable of firing. What this check is
# FOR is "a positive max_w is not itself a refusal", so it now names a sign
# threshold the ceiling can actually reach, and the interaction gets its own
# check below.
check("the smallest sane max_w still starts",
validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
maintenance_charge_w=1), -5000, 5000) == [])
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
# --------------------------------------------------------------------------- #
print("what must NOT be refused - a validator that fires on trivia gets deleted")
# DOCS.md: the arbiter's `supervised` limit still binds the wire to +-max_w, so
# the only cost of the extra headroom is unwind latency after saturation.
check("integrator_max_w above max_w warns but starts",
validate_startup_config(base(max_w=2000, integrator_max_w=9000),
-5000, 5000) == [])
check("integrator_max_w 0 (follow max_w) starts",
validate_startup_config(base(integrator_max_w=0), -5000, 5000) == [])
# Fail-safe AND already a red NOT READY banner naming the entity: a refusal on
# top of that adds nothing an operator can act on.
check("a missing soc_entity is left to the readiness banner",
validate_startup_config(base(soc_entity=""), -5000, 5000) == [])
check("a missing batt_entity likewise",
validate_startup_config(base(batt_entity=""), -5000, 5000) == [])
# The transient case. ESPHome is routinely not up when the add-on boots, and
# refusing here would turn a device that arrives late into a restart loop.
check("a setpoint entity that is configured but not yet found starts",
validate_startup_config(base(), None, None) == [])
check("meter_poll_s with thin but non-zero headroom starts",
validate_startup_config(base(meter_source="homewizard_local", p1_host="m",
meter_poll_s=20, meter_max_age_s=30),
-5000, 5000) == [])
# --------------------------------------------------------------------------- #
print("the refusal must be legible as a refusal, not as a crash")
p = validate_startup_config(base(max_w=8000, setpoint_entity=""), -5000, 5000)
check("several problems are all reported, not just the first", len(p) >= 1)
refuse(p) # prints the banner; the eye is the assertion for its wording
err = ConfigRefused(p)
check("ConfigRefused carries every problem", err.problems == p)
check("...and str() names one of them", str(err) == p[0])
# --------------------------------------------------------------------------- #
print("the LATE refusal, when the device only shows up after the gate has run")
# ⚠️ This path had no test at all and no live demonstration - the review's
# catch. ESPHome is routinely not up when the add-on boots, so hass.limits()
# returns (None, None), the range checks are skipped, and run_control() is the
# first place the device's real rating is ever known. Everything below is about
# what happens when it turns out to conflict.
from app.main import Controller # noqa: E402
class _LateHass:
"""Reports the range only run_control() gets to see."""
def __init__(self, lo, hi):
self.lo, self.hi = lo, hi
self.writes = []
async def limits(self, entity):
return (self.lo, self.hi, 1.0)
async def number(self, *a, **k):
return 0.0
async def set_number(self, entity, value):
self.writes.append(value)
return True
class _Store2:
data = {}
def set(self, *a):
pass
class _Pub2:
enabled = False
def publish(self, *a, **k):
pass
def close(self):
pass
def late(opts_over, lo, hi):
"""Drive run_control() against a device that only reports (lo, hi) now.
⚠️ Returns whether run_control() EXITED ON ITS OWN. That is the assertion
that matters: on a refusal it must return without entering the while loop,
and on a clean config it must not return at all. So the clean case is stopped
from outside after it has had time to write, rather than waited on - a
wait_for() here would just time out, which is the correct behaviour dressed
up as a failure.
"""
async def go():
stop = asyncio.Event()
hass = _LateHass(lo, hi)
# A device narrower than the shipped 5000 W schema ceiling is exactly
# the case that cannot be reached through the Supervisor on the live
# install, so it is reached here instead.
c = Controller(base(**opts_over), hass, _Store2(), _Pub2(), stop=stop)
c.auto = True
task = asyncio.create_task(c.run_control())
for _ in range(30): # up to ~3 s
if task.done():
break
await asyncio.sleep(0.1)
exited = task.done()
if not exited:
c.stopping = True
await asyncio.wait_for(task, timeout=5)
return c, stop, hass, exited
return asyncio.run(go())
c, stop, hass, exited = late({"max_w": 5000}, -3600.0, 3600.0)
check("a device narrower than max_w, discovered late, is refused",
c.refused is not None and len(c.refused) == 1)
check("...naming both values", why(c.refused, "5000") and why(c.refused, "3600"))
check("...signalling amain to wind down", stop.is_set())
check("...and returning instead of looping forever", exited)
# The whole point: run_control() must not fall through into the while loop. A
# single write here would mean it commanded the inverter under a config it had
# just declared unusable.
check("...having never entered the control loop, so it wrote nothing",
hass.writes == [])
check("...and it is recorded in the event log an operator reads",
any("REFUSED" in e for e in c.events))
# The same path when there is no conflict: it must NOT refuse, and it must
# actually regulate - asserted by a write reaching the device, not by absence.
c2, stop2, hass2, exited2 = late({"max_w": 2000}, -5000.0, 5000.0)
check("a late device that agrees does not trip the re-check", c2.refused is None)
check("...and the control loop runs, writing to the device", hass2.writes != [])
check("...and does not signal a shutdown", not stop2.is_set() and not exited2)
# ⚠️ THE FOOTGUN THE REVIEW FOUND. `stop` used to default to None, so this
# construction was legal and the refusal path then returned into a live process
# with no control loop, no exit and no further output.
try:
Controller(base(), _LateHass(-5000.0, 5000.0), _Store2(), _Pub2())
check("a Controller with no stop Event is rejected at construction", False)
except TypeError:
check("a Controller with no stop Event is rejected at construction", True)
# --------------------------------------------------------------------------- #
print()
if fails:
print(f"{len(fails)} FAILED: " + "; ".join(fails))
sys.exit(1)
print("all checks passed")
+495
View File
@@ -0,0 +1,495 @@
"""Runnable check for the sign-disagreement watchdog. `python3 test_watchdog.py`
Every case here is either a fault this must catch or a piece of NORMAL behaviour
it must not mistake for one. The second list is the longer one on purpose: an
alarm that fires on ordinary operation is worse than no alarm, because the next
person switches it off.
The headline validation is not here - it is `sim/replay_sign.py` in the infra
repo, which drives this module over the two captured bus days. This file is the
table-driven half: boundaries, timers, the latch, and the arming gate.
"""
import sys
from datetime import datetime, timedelta, timezone
from app.watchdog import (
SignWatchdog, SignWatchdogConfig, loop_is_following,
)
fails = []
T0 = datetime(2026, 8, 20, 15, 0, 0, tzinfo=timezone.utc)
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def drive(samples, cfg=None, following=True):
"""Feed (offset_s, commanded_w, grid_w) tuples. Returns (wd, trip_offset)."""
wd = SignWatchdog(cfg)
trip_at = None
for item in samples:
offset, cmd, grid = item[0], item[1], item[2]
f = item[3] if len(item) > 3 else following
if wd.evaluate(cmd, grid, f, T0 + timedelta(seconds=offset)) and trip_at is None:
trip_at = offset
return wd, trip_at
def opposed(duration_s, step=5, cmd=-1000, grid=1500, following=True, start=0):
return [(start + t, cmd, grid, following)
for t in range(0, int(duration_s) + 1, step)]
print("the fault it exists to catch")
wd, at = drive(opposed(300))
check("charging into an importing house trips", wd.tripped)
check("and trips at 180 s, not before", at == 180)
check("the reason names both signals", "-1000" in wd.reason and "+1500" in wd.reason)
print(f" e.g. {wd.reason!r}")
wd, at = drive(opposed(300, cmd=2000, grid=-2000))
check("discharging into an exporting house trips too", wd.tripped and at == 180)
print()
print("the boundaries")
wd, _ = drive(opposed(600, cmd=-300, grid=1500))
check("300 W exactly does NOT qualify (strictly greater)", not wd.tripped)
wd, _ = drive(opposed(600, cmd=-301, grid=1500))
check("301 W does", wd.tripped)
wd, _ = drive(opposed(600, cmd=-1000, grid=300))
check("a 300 W meter does not qualify either", not wd.tripped)
wd, _ = drive(opposed(175))
check("175 s of disagreement does not trip", not wd.tripped)
wd, _ = drive(opposed(180))
check("180 s does (>= hold_s)", wd.tripped)
print()
print("continuity - the rule that produced zero false positives on real data")
broken = opposed(175) + [(180, -1000, -1500)] + opposed(175, start=185)
wd, _ = drive(broken)
check("179 s, one agreeing sample, then 175 s more: no trip", not wd.tripped)
check("and the window really was reset", wd.disagree_since is not None)
long_enough = broken + opposed(200, start=365)
wd, _ = drive(long_enough)
check("but a full 180 s after the reset does trip", wd.tripped)
print()
print("things that are NOT faults")
# The load-step transient. Measured on the healthy capture: longest 30 s.
wd, _ = drive(opposed(30) + [(35 + t, 800, 900) for t in range(0, 300, 5)])
check("a 30 s load-step crossover does not trip", not wd.tripped)
# SoC 10 %, Standby, declining a 1350 W discharge. The battery does nothing, so
# the meter stays where it was and the command agrees with it.
wd, _ = drive([(t, 1350, 1350) for t in range(0, 900, 5)])
check("a battery refusing a discharge command cannot trip it", not wd.tripped)
# A frozen meter drives command and reading into agreement, not disagreement.
wd, _ = drive([(t, 800, 800) for t in range(0, 900, 5)])
check("a frozen meter cannot trip it", not wd.tripped)
# Maintenance grid charge: 2500 W of charge against an importing house, for
# hours. Opposed, both huge - and entirely correct.
wd, _ = drive(opposed(7200, cmd=-2500, grid=3000, following=False))
check("two hours of maintenance grid charge does not trip", not wd.tripped)
check("and the timer never even started", wd.disagree_since is None)
wd, _ = drive([(t, -1000, None) for t in range(0, 900, 5)])
check("a missing meter reading does not trip", not wd.tripped)
wd, _ = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
check("a missing reading mid-window RESETS it rather than accumulating",
wd.tripped and wd.disagree_since is not None)
wd, at = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
check("...so the trip lands 180 s after the gap, not after 180 s total",
at == 365)
wd, _ = drive([(t, 0.0, 3000) for t in range(0, 900, 5)])
check("a 0 W command is not a wrong-direction command", not wd.tripped)
print()
print("the latch")
wd, _ = drive(opposed(200))
check("tripped after the fault", wd.tripped)
# The trip commands 0 W, which removes the command side of the comparison.
for t in range(200, 900, 5):
wd.evaluate(0.0, 3000, True, T0 + timedelta(seconds=t))
check("stays tripped once the command is zeroed", wd.tripped)
for t in range(900, 1500, 5):
wd.evaluate(1000, 1000, True, T0 + timedelta(seconds=t))
check("stays tripped even once everything looks healthy again", wd.tripped)
wd.reset()
check("reset() is the only way out", not wd.tripped and wd.disagree_since is None)
check("and the reason is cleared with it", wd.reason == "")
print()
print("the thresholds are configuration, not constants")
cfg = SignWatchdogConfig(min_w=800.0, hold_s=60.0)
wd, at = drive(opposed(300, cmd=-1000, grid=1500), cfg=cfg)
check("a 60 s hold trips at 60 s", wd.tripped and at == 60)
wd, _ = drive(opposed(600, cmd=-700, grid=1500), cfg=cfg)
check("an 800 W gate ignores a 700 W command", not wd.tripped)
print()
print("the configuration that would disarm it is refused")
from app.validate import validate_startup_config # noqa: E402
base = {"setpoint_entity": "number.sp", "meter_source": "off",
"meter_phases": 1, "meter_max_age_s": 30}
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 300},
-5000, 5000)
check("300 W under a 2000 W ceiling is accepted", p == [])
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 2000},
-5000, 5000)
check("a threshold AT max_w is refused", len(p) == 1 and "never fire" in p[0])
# ⚠️ maintenance_charge_w is named here only to keep this case about the SIGN
# rule. MAINT-04 added a second rule against the same ceiling, and a 500 W
# max_w is also below the 2000 W shipped maintenance charge - so without this
# the dict is refused twice, for two correct but different reasons, and the
# `len(p) == 1` below would be measuring the interaction rather than this rule.
p = validate_startup_config({**base, "max_w": 500, "sign_disagree_w": 3000,
"maintenance_charge_w": 500}, -5000, 5000)
check("a threshold above max_w is refused", len(p) == 1 and "never fire" in p[0])
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 1999},
-5000, 5000)
check("one watt under the ceiling is reachable, so accepted", p == [])
print()
print("the arming gate, derived from the REAL arbiter")
# ⚠️ THIS IS THE DECISION THE WHOLE TICKET TURNS ON, and until now it was
# asserted in three comment blocks and verified by nothing: every other case in
# this file passes `following` in as a literal. What has to hold is that the
# expression in main.py - loop won AND the emitted value points the way the loop
# asked AND is no larger - is never True for a resolution the loop did not
# actually get. So run real claims through the real resolve() and derive it.
from app.arbiter import ( # noqa: E402
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY, Claim, resolve,
)
def following_from(claims, asked):
"""THE SHIPPED gate, not a copy of it.
⚠️ This used to transcribe main.py's expression with a comment saying
"keep the two in step", which is exactly the arrangement that does not keep
two things in step. Measured: editing the shipped gate alone to
`winner in ("loop", "peak")` left this suite - including the P_PEAK row below,
whose entire job is to catch that edit - completely green, while the watchdog
went blind for the duration of every peak event. Import it or the P_PEAK
assertion is decoration.
"""
r = resolve(claims)
return r, loop_is_following(r, asked)
MAXW = Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w")
DEV = Claim.limit("device", P_SAFETY, -5000, 5000, "rating")
# name, claims, what the loop asked, expected `following`
TABLE = [
("the loop alone, unopposed",
[Claim.set("loop", P_LOOP, 900)], 900, True),
("the loop bound by max_w - reduced, not redirected",
[Claim.set("loop", P_LOOP, 4000), MAXW], 4000, True),
("charging, bound by max_w on the other side",
[Claim.set("loop", P_LOOP, -4000), MAXW], -4000, True),
("maintenance owns the setpoint outright",
[Claim.set("loop", P_LOOP, 900),
Claim.set("maintenance", P_MAINTENANCE, -2500, "charge"), MAXW], 900, False),
("maintenance charge-only clamps the loop to 0 W",
[Claim.set("loop", P_LOOP, 900),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only"),
MAXW], 900, False),
# ⚠️ THE CASE `winner == \"loop\"` ALONE WOULD HAVE GOT WRONG. 1500 W, not
# the default 2500 W: at max_w 2000 a -2500 hi against a -2000 lo is an
# arbiter contradiction, not a charge - see main.py.
("cheap-window charge REDIRECTS the loop while it still 'wins'",
[Claim.set("loop", P_LOOP, 500),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-1500, reason="cheap-window"),
MAXW], 500, False),
("...and the contradiction at the shipped defaults is not following either",
[Claim.set("loop", P_LOOP, 500),
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-2500, reason="cheap-window"),
MAXW], 500, False),
("a lo limit RAISES the magnitude without flipping the sign",
[Claim.set("loop", P_LOOP, 200),
Claim.limit("floor", P_SAFETY, lo=800), MAXW], 200, False),
("a safety stop wins outright",
[Claim.set("loop", P_LOOP, 900),
Claim.set("safety", P_SAFETY, 0.0, "stopped"), MAXW], 900, False),
("no claims at all - the arbiter's own failsafe",
[MAXW, DEV], None, False),
("the loop asked for zero",
[Claim.set("loop", P_LOOP, 0.0), MAXW], 0.0, False),
# The forward hazard, asserted as it stands TODAY rather than as it should
# be. When peak shaving lands, these expectations are what have to change.
("peak shaving at P_PEAK disarms the gate (loop_is_following's forward hazard)",
[Claim.set("loop", P_LOOP, 900),
Claim.set("peak", P_PEAK, 1800, "shaving"), MAXW], 900, False),
# ⚠️ AND THE ROW ABOVE CANNOT DETECT A WIDENED GATE ON ITS OWN, which was
# found by trying it: with the shipped gate edited to
# `winner in ("loop", "peak")` that case STILL comes out False, because peak
# shaving asked for MORE than the loop and the magnitude term rejects it
# anyway. The winner term is masked. This row isolates it - a peak claim
# smaller than the loop's ask and pointing the same way, so `winner` is the
# only term that can decide - and it is what actually turns red if the gate
# is widened without anyone revisiting the hazard.
("...and with peak BELOW the loop's ask, only the winner term separates them",
[Claim.set("loop", P_LOOP, 1800),
Claim.set("peak", P_PEAK, 900, "shaving"), MAXW], 1800, False),
]
for name, claims, asked, expect in TABLE:
r, got = following_from(claims, asked)
check(f"{name} -> following={expect}", got is expect)
if got is not expect:
print(f" resolution was {r.explain()!r}")
# And the gate is never True when the loop did not win, whatever else is going on.
check("no configuration above arms the gate without the loop winning",
all(not following_from(c, a)[1]
for _, c, a, _ in TABLE if following_from(c, a)[0].winner != "loop"))
print()
print("end to end: the trip is COMMAND ZERO, not alarm-only")
# ⚠️ THE FAULT INJECTED HERE IS A NEGATIVE GAIN, and that is not a contrivance -
# it is the minimal faithful model of what this watchdog is for. The check
# compares the loop's OUTPUT DIRECTION against the INPUT STATE it was regulating,
# so what it detects is a loop whose two ends have become decoupled in sign: a
# gain, a claim or a strategy with its polarity inverted, or an integrator so far
# wound up that unwinding takes minutes. (Illusmart's was the last one: it
# reached -14 768 W against a +-5000 W rail while writing once every 20-60 s, and
# that arithmetic alone is 5-15 minutes of wrong-direction command.)
#
# `gain` is float(0.05,1.0) in the schema, so this is not a reachable
# configuration - it is a stand-in for a code regression, which is the case a
# unit test can actually hold the line on.
import asyncio # noqa: E402
from app.main import Controller # noqa: E402
class _Hass:
def __init__(self):
self.writes = []
async def limits(self, entity):
return (-5000.0, 5000.0, 1.0)
async def number(self, entity, invert=False):
# A house importing 2000 W, steadily, whatever the battery does.
return {"sensor.grid": 2000.0, "sensor.soc": 50.0,
"sensor.batt": 0.0}.get(entity)
async def set_number(self, entity, value):
self.writes.append(float(value))
return True
class _S:
data = {}
def set(self, *a):
pass
def get_time(self, *a):
return None
class _P:
enabled = False
def publish(self, *a, **k):
pass
def close(self):
pass
async def _e2e():
hass = _Hass()
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": -0.6,
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
c = Controller(opts, hass, _S(), _P(), stop=asyncio.Event())
c.auto = True
c.dev_min, c.dev_max = -5000.0, 5000.0
seen_wrong_way = False
for _ in range(12):
await c.read_inputs()
await c.cycle()
if c.target < -300 and not c.sign_wd.tripped:
seen_wrong_way = True
await asyncio.sleep(0.25)
return c, hass, seen_wrong_way
ctrl, hass, wrong_way = asyncio.run(_e2e())
check("the broken loop really did command charge into an import first", wrong_way)
check("the watchdog tripped", ctrl.sign_wd.tripped)
check("the commanded value is 0 W", ctrl.target == 0.0)
check("0 W actually reached the device", 0.0 in hass.writes)
check("and it got there through the failsafe claim, not by accident",
"failsafe" in ctrl.reason)
print(f" status line: {ctrl.reason!r}")
check("the status page says so in words",
any("SIGN-DISAGREEMENT FAILSAFE" in c["text"] for c in ctrl.checks()))
check("the banner leads with it",
"FAILSAFE" in ctrl.status_payload()["banner"])
check("it stays at 0 W on later cycles too",
hass.writes[-1] == 0.0 and hass.writes.count(0.0) >= 1)
# ⚠️ THIS USED TO BE `check("MQTT reports the failsafe state", ctrl.sign_wd.tripped)`
# which restates the assertion three lines above and never touches the payload.
# The `status: "failsafe"` value was shipped untested. Capture what publish()
# actually hands the broker.
published = {}
ctrl.mqtt = type("P", (), {"enabled": True,
"publish": lambda _s, v: published.update(v),
"close": lambda _s: None})()
ctrl.publish()
check("MQTT's controller-status sensor reports 'failsafe'",
published.get("status") == "failsafe")
ctrl.sign_wd.reset()
ctrl.publish()
check("...and goes back to 'running' once cleared",
published.get("status") == "running")
print()
print("the latch survives a restart - it is the only thing between a tripped")
print("controller and the first thing an operator will try")
# ⚠️ THE BLOCKER THIS FILE MISSED FIRST TIME ROUND. `auto` is persisted and
# `tripped` was not, so reconstructing a Controller against the same Store -
# which is exactly what a container restart does - came back armed, into the
# fault, with no operator involved: tripped=False, banner NOT READY, and it
# resumed commanding -1000 then -2000 W before re-tripping 180 s later.
class _MemStore:
"""A Store that keeps its dict across "restarts", like the real file does."""
def __init__(self):
self.data = {"phase": "idle", "sign_tripped": False, "sign_reason": ""}
def set(self, k, v):
self.data[k] = v
def get_time(self, *a):
return None
async def _restart():
shared = _MemStore()
hass1 = _Hass()
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": -0.6,
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
a = Controller(opts, hass1, shared, _P(), stop=asyncio.Event())
a.auto = True
a.dev_min, a.dev_max = -5000.0, 5000.0
for _ in range(12):
await a.read_inputs()
await a.cycle()
await asyncio.sleep(0.25)
# The restart. Same options, same store, brand new Controller and Hass.
hass2 = _Hass()
b = Controller(opts, hass2, shared, _P(), stop=asyncio.Event())
b.auto = True
b.dev_min, b.dev_max = -5000.0, 5000.0
for _ in range(6):
await b.read_inputs()
await b.cycle()
await asyncio.sleep(0.05)
return a, b, shared, hass2
pre, post, store, hass2 = asyncio.run(_restart())
check("it tripped before the restart", pre.sign_wd.tripped)
check("the trip reached the store", store.data["sign_tripped"] is True)
check("...with the reason beside it, so the operator is told why",
"SIGN_DISAGREEMENT" in store.data["sign_reason"])
check("the new Controller comes back TRIPPED", post.sign_wd.tripped)
check("...and says why, restored rather than re-detected",
"SIGN_DISAGREEMENT" in post.sign_wd.reason)
check("...commands 0 W from its very first cycle", post.target == 0.0)
check("...and never commanded anything else after the restart",
hass2.writes != [] and set(hass2.writes) == {0.0})
check("the banner still leads with the failsafe",
"FAILSAFE" in post.status_payload()["banner"])
# ⚠️ TWO PRESSES, and the first one must NOT clear it. `auto` is True while
# tripped, so the first press stops control; only the transition back to True
# clears. That is the documented behaviour and it is worth an assertion, because
# a one-press clear would be reachable by an operator who never read the banner.
asyncio.run(post.handle_action("auto_toggle")) # -> stopped
check("pressing stop does not clear the failsafe",
post.sign_wd.tripped and store.data["sign_tripped"] is True)
asyncio.run(post.handle_action("auto_toggle")) # -> started
check("pressing start DOES clear it, and clears the store with it",
not post.sign_wd.tripped and store.data["sign_tripped"] is False
and store.data["sign_reason"] == "")
# One more restart from the cleared store, to prove the clear persisted too.
fresh = Controller({"setpoint_entity": "number.sp", "meter_source": "off"},
_Hass(), store, _P(), stop=asyncio.Event())
check("...so the next restart comes back armed and untripped, as it should",
not fresh.sign_wd.tripped)
# ⚠️ THE WRITE ORDERING IS AN INVARIANT, SO IT GETS AN ASSERTION. main.py writes
# `sign_reason` and THEN `sign_tripped`, each one its own `save()`, so that a
# process that dies between the two leaves a reason nothing reads - harmless -
# rather than a latch with no explanation for the operator who has to decide
# whether to clear it. Documented reasoning is not enforcement: swapping those two
# lines used to pass every check in this file.
#
# The death is modelled as the second write raising. In the field it is a power
# cut or a container kill (Store.save() swallows OSError rather than raising), so
# what is asserted here is the PROPERTY - what survives on disk - not the
# mechanism.
class _CrashOnFlag(_MemStore):
def set(self, k, v):
if k == "sign_tripped" and v:
raise RuntimeError("power cut, mid-trip")
super().set(k, v)
async def _crash_mid_write():
store = _CrashOnFlag()
hass = _Hass()
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": -0.6,
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
c = Controller(opts, hass, store, _P(), stop=asyncio.Event())
c.auto = True
c.dev_min, c.dev_max = -5000.0, 5000.0
died = False
for _ in range(12):
try:
await c.read_inputs()
await c.cycle()
except RuntimeError:
died = True
break
await asyncio.sleep(0.25)
return store, died
crashed_store, died = asyncio.run(_crash_mid_write())
check("the second write is the one that sets the flag", died)
check("a crash between the two writes leaves the REASON on disk",
"SIGN_DISAGREEMENT" in crashed_store.data.get("sign_reason", ""))
check("...and never a latch with nothing to explain it",
not crashed_store.data.get("sign_tripped"))
print()
if fails:
print(f"{len(fails)} FAILED: {', '.join(fails)}")
sys.exit(1)
print("all checks passed")