Compare commits
25
Commits
@@ -0,0 +1,10 @@
|
||||
# This add-on is deployed to a Linux container. core.autocrlf=true on the
|
||||
# authoring box gave the checkout CRLF, so a plain copy shipped CRLF files -
|
||||
# run.sh with CRLF is a "bad interpreter" failure, and any hash-based drift
|
||||
# check between repo and deployment fails for a reason that has nothing to do
|
||||
# with the code. Deploy with:
|
||||
# git -c core.autocrlf=false archive release/1.0 goodwe_controller | tar -x
|
||||
# which is how 0.3.0 went out, byte-identical to the blobs.
|
||||
* text=auto eol=lf
|
||||
*.png binary
|
||||
*.gz binary
|
||||
+19
-2
@@ -12,7 +12,7 @@ a GoodWe GW5000S-BP.
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| running | `local_goodwe_controller` **0.2.0**, `boot: auto`, holding grid at zero |
|
||||
| running | `local_goodwe_controller` **0.4.0**, `boot: auto`, holding grid at zero |
|
||||
| installed as | a **Local** add-on: `/addons/goodwe_controller` on HA OS at 192.168.2.158 |
|
||||
| repo | Gitea `admin/goodwe-addon` (ssh://git@192.168.2.147:2222) — **private** |
|
||||
| tuning | gain 0.6, `max_w` 5000, slew 1000, deadband 15, step 10, saturation 500/3, heartbeat 10 s |
|
||||
@@ -52,9 +52,26 @@ Run the checks before deploying. No framework needed:
|
||||
|
||||
```bash
|
||||
cd goodwe_controller
|
||||
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py
|
||||
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py \
|
||||
&& python3 test_validate.py && python3 test_p1.py && python3 test_watchdog.py \
|
||||
&& python3 test_loop.py
|
||||
```
|
||||
|
||||
`test_watchdog.py` covers SAFETY-02's logic and its trip path. Its headline
|
||||
validation is not here at all: `sim/replay_sign.py` in the infra repo drives the
|
||||
same module over the two captured RS485 days and must fire on all four of the
|
||||
2026-08-20 episodes and stay silent on 2026-08-23. That needs both checkouts —
|
||||
`GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py`.
|
||||
|
||||
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
|
||||
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
|
||||
wall-clock property about it (SAFETY-12); mocking the clock there would leave the
|
||||
assertion testing the mock. The other six suites together are ~440 checks and finish in
|
||||
seconds — `test_watchdog.py` spends ~3 s of that driving a real `Controller` through a
|
||||
trip. If you shorten `test_loop.py`'s windows, re-measure and correct this figure —
|
||||
an understated runtime is what makes a slow test look like a hung one, and a slow test
|
||||
that looks hung gets deleted.
|
||||
|
||||
---
|
||||
|
||||
## 3. Known broken / unfinished
|
||||
|
||||
@@ -1,5 +1,378 @@
|
||||
# Changelog
|
||||
|
||||
## 0.5.0
|
||||
|
||||
**SAFETY-02 — the sign-disagreement watchdog.** The add-on now watches whether
|
||||
the setpoint it is emitting and the grid figure it is regulating on point the
|
||||
same way. If they oppose each other, both over `sign_disagree_w` (300 W), for
|
||||
`sign_disagree_s` (180 s) **continuously**, it files a failsafe claim at
|
||||
`P_SAFETY`, commands **0 W**, and latches there until an operator starts control
|
||||
again. New module `app/watchdog.py`; new options `sign_disagree_w` and
|
||||
`sign_disagree_s`.
|
||||
|
||||
This is the gap the existing failsafes leave open. The stale-input watchdog asks
|
||||
whether the meter is still talking, the saturation freeze asks whether the
|
||||
inverter can follow, the output clamp asks whether the number is too big — a
|
||||
loop can pass all three while charging the battery out of the grid, because the
|
||||
only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly
|
||||
that four times in one day, for up to 77 minutes at a stretch, and reached a
|
||||
commanded −14 768 W against a ±5000 W inverter.
|
||||
|
||||
Validated against that day. `sim/replay_sign.py` in the infra repo drives this
|
||||
module over the committed RS485 captures of both 2026-08-20 (the four episodes)
|
||||
and 2026-08-23 (healthy): **18 trips on the fault day, every one inside a window
|
||||
`NOTES.md` §4.7 accounts for, and 0 on the healthy day.** The four episodes do
|
||||
share one signature rather than merely resembling each other — sign agreement
|
||||
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 92.9 % on the healthy day.
|
||||
|
||||
Three decisions worth knowing about:
|
||||
|
||||
- **It is disarmed whenever the grid-following loop is not what is driving.**
|
||||
Sign agreement is a property of a loop that follows the meter. A maintenance
|
||||
grid charge opposes the meter *by design* — 2500 W of charge into a house
|
||||
drawing 500 W is +3000 W on the meter against a −2500 W command, for hours —
|
||||
and armed unconditionally this would trip on every maintenance cycle. The gate
|
||||
tests the emitted number, not the winning claim's name: a limit claim can let
|
||||
the loop "win" and still replace its value with one pointing the other way.
|
||||
- **The trip latches.** Commanding 0 W removes the command side of the
|
||||
comparison, so the disagreement always clears the moment the trip works.
|
||||
Un-latched, this would trip, clear, and hand the actuator back to the loop that
|
||||
was driving the wrong way, every three minutes forever.
|
||||
- **`sign_disagree_w` at or above `max_w` is refused at startup** (validator rule
|
||||
5). The arbiter never lets a command exceed `max_w`, so such a threshold makes
|
||||
the watchdog incapable of firing while the status page still reports it armed.
|
||||
A disarmed guard that advertises itself as armed is the failure mode this
|
||||
project keeps refusing to ship.
|
||||
|
||||
What it does **not** catch, stated so nobody assumes otherwise: an inverter that
|
||||
acts opposite to what it was told moves the meter *further* the same way, so
|
||||
command and meter agree while everything runs away. That is the saturation
|
||||
freeze's job, which compares the command against the battery's actual power.
|
||||
|
||||
`test_validate.py`'s "the smallest sane max_w still starts" case now names a
|
||||
reachable sign threshold, because a 1 W ceiling genuinely does disarm the 300 W
|
||||
default and is now correctly refused.
|
||||
|
||||
## 0.4.0
|
||||
|
||||
**CFG-01.** The add-on now refuses to start on a configuration it cannot honour,
|
||||
instead of logging a line and carrying on. `validate_startup_config()` runs in
|
||||
`amain()` before the broker, the web server or any task exists, so a refusal
|
||||
cannot leave half a controller running behind a UI.
|
||||
|
||||
It refuses only where continuing produces one of two outcomes: **(a)** a stated
|
||||
limit is untrue - the operator configured a bound and a lower layer silently
|
||||
enforces a different one - or **(b)** the add-on is inert and indistinguishable
|
||||
from healthy. (b) is not a special case of (a): with no `setpoint_entity`, layer
|
||||
1 pinning the inverter at 0 W is the failsafe *working*. The system does not
|
||||
become unsafe, it becomes a convincing impression of a working controller.
|
||||
|
||||
Four things qualify:
|
||||
|
||||
- **`max_w` above (or below) the setpoint device's own rating.** This is the one
|
||||
that changed behaviour. It used to warn `the device wins` and run anyway, with
|
||||
`write_setpoint()` silently clamping, so the configured ceiling was never the
|
||||
real one and the only evidence had scrolled off the log. The refusal names the
|
||||
configured value, the device's value, and which wins.
|
||||
- **No `setpoint_entity`.** A controller with no actuator: every write is a
|
||||
no-op, the device rating is never read, and the ESP32 heartbeat that holds off
|
||||
the layer-1 failsafe never happens. It ran, looked healthy, and moved nothing.
|
||||
- **A `meter_source` that can never produce a reading** - missing `p1_host`,
|
||||
missing `p1_net_entity`, a blank MQTT topic, a phase list disagreeing with
|
||||
`meter_phases`, an unknown source name, or a `meter_poll_s` at or past
|
||||
`meter_max_age_s`. These were already caught, but they only *disabled
|
||||
ingestion*, which leaves the grid reading None forever: permanent "inputs
|
||||
missing", 0 W, and a status page indistinguishable from a healthy meter nobody
|
||||
has sent anything to yet.
|
||||
- **`meter_max_age_s` above the firmware's ingest veto.** The schema accepts
|
||||
`int(5,300)`; the ESP32's threshold is a compile-time `max_age_s: "30"` and it
|
||||
trips layer 1 at `p1_age_s >= 30`. Set 120 and the add-on treats a 119 s
|
||||
reading as fresh and keeps commanding, while the firmware has already vetoed
|
||||
and is holding the inverter at 0 W - healthy meter, running controller,
|
||||
nothing moving, and no line anywhere saying the number you set was overruled.
|
||||
Structurally the same fault as the `max_w` case. Only *above* the veto is
|
||||
refused: below it the add-on gives up first, which is fail-safe and visible on
|
||||
its own status page. Mirrored as `validate.FIRMWARE_INGEST_VETO_S` - it cannot
|
||||
be imported from a compile-time YAML substitution, so it carries a note about
|
||||
the one direction in which it can go stale.
|
||||
|
||||
`max_w` at or below zero is refused too. Schema-blocked on a real install, but
|
||||
`validate_startup_config()` is now also the simulation suite's entry point, and
|
||||
a non-positive `max_w` inverts the arbiter's `supervised` bounds into a
|
||||
contradiction that resolves to 0 W - i.e. it would read as a safety trip rather
|
||||
than as the typo it is.
|
||||
|
||||
The predicates for the meter group still live in `p1.validate_meter_options()`,
|
||||
which `build_source()` also calls - one definition, two callers, not two
|
||||
competing validators. Two transports gained a check they never had: `ha_dsmr`
|
||||
with only one of its two entities, and `mqtt_p1` with a blank topic, both of
|
||||
which previously built a transport that could never read.
|
||||
|
||||
Deliberately **not** refused, because it is untidy rather than unsafe:
|
||||
`integrator_max_w` above `max_w` (the arbiter still bounds the wire to ±max_w,
|
||||
so the cost is unwind latency, not amperage - warned), a missing `soc_entity` /
|
||||
`batt_entity` (fail-safe, and already a red NOT READY banner naming it), a
|
||||
`setpoint_entity` that has not appeared on the Core API yet (ESPHome is routinely
|
||||
late; refusing would make a slow boot need a human - re-checked once the real
|
||||
rating arrives), and a thin-but-nonzero `meter_poll_s` margin.
|
||||
|
||||
A refusal is legible as a refusal: a banner that says in words that this is a
|
||||
configuration problem and nothing is broken, the numbered problems, no traceback,
|
||||
and exit status 78 (`EX_CONFIG`).
|
||||
|
||||
**SAFETY-12.** The control loop now evaluates on a clock as well as on a change.
|
||||
`run_control()` ran `cycle()` only when the meter value differed from the
|
||||
previous poll, so a meter that repeated a value ran **no control cycles at
|
||||
all** - while the heartbeat went on re-emitting the last command and the
|
||||
firmware went on putting it on the wire every 2 s. Layer 1 stayed fed, every
|
||||
indicator read healthy, and a command computed from an old reading kept being
|
||||
executed through whatever the load did next. Measured on the rig during TEL-05:
|
||||
70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
|
||||
|
||||
**It was worse than a latency limit: it was a safety claim that could not
|
||||
fire.** `stale_input_s` and the `inputs missing -> 0 W` claim both live *inside*
|
||||
`cycle()`. Pre-fix, if the meter value happened to be constant, `cycle()` was
|
||||
never called again - so that claim had no way to run. Constant meter, SoC entity
|
||||
dying at t=4 s, same binary:
|
||||
|
||||
```
|
||||
pre-fix writes: [(0.0, 220.0), (0.0, 220.0), (10.1, 220.0)]
|
||||
final target: 220.0 W reason: 'loop -> 220 W'
|
||||
post-fix writes: [(0.0, 220.0), (0.0, 220.0), (3.0, 430.0), (9.1, 0.0), (10.1, 0.0)]
|
||||
final target: 0.0 W reason: 'safety -> 0 W'
|
||||
```
|
||||
|
||||
The pre-fix controller held 220 W through the entire input outage with its
|
||||
status line still reading `loop -> 220 W`, and layer 1 does not cover that case
|
||||
on a `meter_source: off` install: no P1 age sensor is published, so the firmware
|
||||
has nothing to veto on, while the heartbeat keeps its watchdog fed. So the old
|
||||
behaviour was not "holds a stale command safely" - it was a failsafe that a
|
||||
repeating meter switched off. `test_loop.py` asserts both halves.
|
||||
|
||||
`cycle_floor_s` (default **15 s**) is a deadline on the gap between cycles, not
|
||||
a second scheduler: every cycle resets it, whichever trigger fired. On a healthy
|
||||
meter it never elapses, so the cycle rate, the write sequence and therefore the
|
||||
per-cycle gain the tuning was measured against are unchanged - asserted in
|
||||
`test_loop.py` by driving the real loop twice on one binary (a huge
|
||||
`cycle_floor_s` reproduces the old behaviour exactly) and comparing the
|
||||
commanded values.
|
||||
|
||||
The reset is not the only thing holding that up, and the other argument is the
|
||||
sturdier one: the combined cycle rate is `max(arrival rate, 1/floor)`, never the
|
||||
sum. At 1/15 s the floor is strictly slower than the ~1/5 s arrival rate, so
|
||||
even a hypothetical floor racing the arrivals could not exceed the nominal
|
||||
healthy rate. The re-tune is unreachable by construction. ⚠️ That holds only
|
||||
while `cycle_floor_s` stays above the meter's update interval, and the schema
|
||||
minimum is 5 s - which is exactly the reference meter's interval. Nothing
|
||||
enforces the relationship; `validate.py` is the obvious home for it and does not
|
||||
have it yet.
|
||||
|
||||
Observed over six real minutes on the same rig, one binary, meter held at a
|
||||
literally constant 350.0 W: **before, 1 cycle** (at startup) and then nothing,
|
||||
the command stuck at 220 W against a 350 W import for the rest of the window.
|
||||
**After, 24 cycles**, worst gap 15.14 s, and the ordinary PI ramp doing its job -
|
||||
220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle,
|
||||
rail at t=136 s and flat after. Three minutes with the meter parked at the
|
||||
target instead: **1 cycle before, 12 after, and 19 writes either way - the same
|
||||
19**. Three minutes on a normally-changing meter: **36 cycles and 49 writes on
|
||||
both sides, the same values in the same order.** The heartbeat write count never
|
||||
moves; the only writes the fix adds are the ten the loop was supposed to be
|
||||
making all along.
|
||||
|
||||
15 s is bracketed, not round.
|
||||
|
||||
**Below it, ~11 s, and it arises more routinely than a dropped poll.**
|
||||
`HomeWizardLocalSource` polls at 5.0 s against a meter that updates every 4.97 s
|
||||
(NOTES.md:640). Two near-equal periods beat, so roughly once every ~14 minutes
|
||||
the poller steps over an update entirely - a ~10 s gap between changed values on
|
||||
a perfectly healthy meter, plus up to 1 s for the 1 s tick to notice. A failed
|
||||
HTTP poll (retried on the next tick, no backoff) adds another 5 s. The floor
|
||||
sits above the beat-skip so it does not fire on that alone; what it takes to
|
||||
reach 15 s is a beat-skip *and* a failed poll coinciding.
|
||||
|
||||
**Above it, 30 s.** `meter_max_age_s` is 30 s, past which there is no reading to
|
||||
evaluate, and the firmware's ingest veto is also 30 s - so the loop is
|
||||
guaranteed to have re-decided at least twice inside any window in which layer 1
|
||||
might otherwise be the only thing deciding. ⚠️ The default is therefore not
|
||||
independently justified at 15: if the firmware's veto ever moves, this moves
|
||||
with it. Noted beside the constant in `main.py`.
|
||||
|
||||
It is also exactly `stale_input_s`, this system's existing answer to "how long
|
||||
may we hold without re-deciding".
|
||||
|
||||
A floor cycle runs the **full** law on the same inputs, integrator included. In
|
||||
P1 mode the freshness question is already answered upstream and answered harder
|
||||
- past `meter_max_age_s` the reading is None, which is "inputs missing", which
|
||||
is a `P_SAFETY` 0 W claim - so a floor cycle there can only ever run on a reading
|
||||
this system already calls fresh. ⚠️ That is transport-conditional: with
|
||||
`meter_source: off`, `read_inputs()` takes the grid figure straight from
|
||||
`hass.number()` with **no age gate at all**, so a Home Assistant entity that has
|
||||
gone quiet reads as current on that path, with or without this change. Running
|
||||
the full law is still right there - the alternative is a degraded second law
|
||||
reasoning about an age nobody measured - but the floor does not make that path
|
||||
fresh. The integrator advances per *cycle*, not per second,
|
||||
so bounding the gap bounds the accumulation; `integrator_max_w` bounds it after
|
||||
that. A gentler second law for floor cycles would be a second set of dynamics
|
||||
nobody can test on this hardware.
|
||||
|
||||
⚠️ **This is not a freeze detector**, and TEL-05 established one cannot be built
|
||||
here: at the converged -10 W target a 1 Wh register needs ~6 minutes to move
|
||||
while the power figure legitimately repeats, so any threshold on `unchanged_s`
|
||||
false-trips at the exact operating point we run at. Nothing in this change
|
||||
decides whether a repeated reading is *true*. It stops "the number is the same"
|
||||
from meaning "do not think". The consequence, stated plainly: against a meter
|
||||
genuinely frozen at a wrong value the loop will now correct toward that wrong
|
||||
value rather than hold a stale command, bounded by `max_w`, the arbiter and the
|
||||
device rating. That was already what happened to a lying meter whose value
|
||||
merely jittered; bit-exact repetition was never a safety property.
|
||||
|
||||
`DOCS.md`'s "Saturation is counted in cycles, not seconds" section documented
|
||||
the old behaviour as an accepted deviation. It is **qualified, not deleted**:
|
||||
the deviation survives (the window is still counted in cycles, and 3 x 15 s is
|
||||
still not the specification's 10 s) but it is now bounded at 45 s instead of
|
||||
open-ended, and the passage's second justification - "nothing accumulates while
|
||||
it is stalled" - is called out as having covered integrator windup and not
|
||||
staleness, which was the actual hazard. The same wrong argument in
|
||||
`control.py`'s saturation comment is corrected too.
|
||||
|
||||
**TEL-04.** `meter_source: ha_signed` reads a single *signed* power entity, which
|
||||
is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two
|
||||
unsigned registers and refuse negatives, so neither fits the meter installed here.
|
||||
|
||||
**TEL-05.** `meter_source: homewizard_local` polls the meter's own local API
|
||||
directly. This exists because of something the HA paths cannot do: Home Assistant
|
||||
fires no state change for a repeated reading and exposes no arrival signal at
|
||||
all, so `sensor.p1_sample_age_s` on those transports measures time since the
|
||||
*value changed*, not since the meter *reported*. Real captured data has gaps of
|
||||
42 s and 97 s between changes on a perfectly healthy meter - long enough for a
|
||||
30 s staleness threshold to command 0 W for no reason. Every HTTP response to the
|
||||
local API is a genuine arrival, so the age means what it says.
|
||||
|
||||
Verified on the rig against a literally constant 350.0 W for 70 s - the exact
|
||||
state where the HA path recorded zero samples in 45 s - with 14 arrivals and the
|
||||
age never exceeding the poll cadence.
|
||||
|
||||
Set `p1_host` to the meter's address and `meter_poll_s` (default 5 s, matching
|
||||
the meter's own ~5 s update). Still defaults to `off`; nothing changes for an
|
||||
install that does not opt in.
|
||||
|
||||
Freeze detection is separate and deliberately not thresholded: a meter answering
|
||||
200 OK with a stale number *is* arriving, so no arrival stamp can flag it. The
|
||||
energy registers carry that as `unchanged_s`, surfaced on the status line for a
|
||||
human to read rather than alarmed on - at a converged -10 W a 1 Wh register needs
|
||||
about six minutes to move, so any threshold would false-trip at the target
|
||||
operating point.
|
||||
|
||||
## Unreleased
|
||||
|
||||
**TEL-05.** A fourth `meter_source`, `homewizard_local`, which polls a
|
||||
HomeWizard P1's **own local API** (`GET /api/v1/data`) instead of watching a
|
||||
Home Assistant entity. Set `p1_host` to the meter's address; `meter_poll_s`
|
||||
(default 5 s, the meter's own update rate) sets the cadence.
|
||||
|
||||
✅ **This is the first transport whose `sensor.p1_sample_age_s` measures when
|
||||
the meter *reported*, and therefore the first one a firmware watchdog may
|
||||
threshold.** Every HTTP response is an arrival: the meter answered, now, with
|
||||
its current reading, and whether the *number* moved is not consulted. Home
|
||||
Assistant cannot express that at all — a repeated reading emits no
|
||||
`state_changed`, advances `last_reported` on neither serialiser, and
|
||||
`state_reported` is not subscribable ("Event filter is required"). On
|
||||
`ha_signed` that made a healthy meter under a flat load indistinguishable from
|
||||
a dead one, and our own capture of this house's meter goes 42.2 s and 97.0 s
|
||||
between changes — both past the default `meter_max_age_s` of 30, i.e. a false
|
||||
trip to 0 W on a meter that is fine. If you have a HomeWizard P1, move to this
|
||||
mode.
|
||||
|
||||
Everything TEL-01 established is reused, not re-implemented: ingest
|
||||
timestamping, `meter_max_age_s`, the clock-recomputed age, the plausibility
|
||||
bounds and the §20 unsigned-decode rejection, and the same `split_signed` sign
|
||||
convention `ha_signed` uses. A failed or timed-out poll submits nothing, so it
|
||||
is a *missing* reading — never 0 W — and it does not reset the age.
|
||||
|
||||
Verified on the ENV-01 rig against `sim/hwsim.py`, steady and with `--fault
|
||||
freeze` injected. Still defaults to `off`.
|
||||
|
||||
⚠️ **An arrival stamp still cannot see a *frozen* meter**, and no arrival
|
||||
detector can: a meter answering `200 OK` forever with a stale number is
|
||||
arriving. The local API does expose what the HA path never had — the
|
||||
`total_power_*_kwh` registers stop advancing — and the transport tracks it as
|
||||
`unchanged_s`, but that is deliberately **not** folded into the age and not
|
||||
thresholded: this controller regulates grid power toward ~0 W, and at a
|
||||
converged −10 W the export register needs six minutes to move by its 1 Wh
|
||||
resolution while the power figure legitimately repeats. Thresholding it at 30 s
|
||||
would rebuild the false-trip limit cycle at the exact operating point we aim
|
||||
for. Freeze detection needs the low-power case solved first, separately. It is
|
||||
shown on the status page's P1 line instead — leaving it unthresholded only
|
||||
holds up if a human can read it, so now they can.
|
||||
|
||||
**TEL-04.** A third `meter_source`, `ha_signed`, reading **one signed** Home
|
||||
Assistant entity: positive = import, negative = export. That is the shape a
|
||||
HomeWizard P1 publishes (`sensor.p1_meter_active_power`), and it is the meter
|
||||
actually fitted here - which neither TEL-01 transport can read, because
|
||||
`ha_dsmr` needs two unsigned registers and refuses a negative one, i.e. every
|
||||
exporting telegram. Set `p1_net_entity`, and `p1_phase_net_entities` for the
|
||||
per-phase capacity-tariff figures on a three-phase connection.
|
||||
|
||||
Everything TEL-01 established is inherited rather than re-implemented - the
|
||||
new transport is a subclass of the `ha_dsmr` one overriding only which
|
||||
entities it wants and how they become a sample. So ingest timestamping,
|
||||
`meter_max_age_s`, `sensor.p1_sample_age_s` recomputed against the clock and
|
||||
republished once a second, the plausibility bounds, and `unavailable` /
|
||||
`unknown` treated as a *missing reading and never 0 W* all behave identically
|
||||
across the three sources.
|
||||
|
||||
Still defaults to `off`; an existing install is unaffected until it opts in.
|
||||
|
||||
⚠️ **`sensor.p1_sample_age_s` is published on `ha_signed`, but must not yet be
|
||||
thresholded by the ESP32 stale-input watchdog.** On the HA WebSocket paths the
|
||||
age is stamped from `state_changed`, so it measures time since the value
|
||||
*changed*, not since the meter *reported* - and Home Assistant exposes no
|
||||
arrival signal for a repeated reading (no `state_changed`, no `last_reported`
|
||||
movement on either serialiser, and `state_reported` is not subscribable over
|
||||
the WebSocket). Measured on the ENV-01 rig against the real HomeWizard
|
||||
integration. `ha_dsmr` mostly escapes it because a telegram moves several
|
||||
entities at once; `ha_signed` has one, so a healthy meter under a flat load is
|
||||
indistinguishable from a dead one. Our own capture has the house meter going
|
||||
42.2 s and 97.0 s between changes. Raising `meter_max_age_s` does not fix that,
|
||||
it only chooses which error you get; the fix is an arrival stamp from the meter
|
||||
itself and is a separate ticket. Full detail in DOCS.md.
|
||||
|
||||
## 0.3.0
|
||||
|
||||
**SAFETY-04.** The control law's integrator is now an explicit accumulator,
|
||||
bounded independently of the output clamp instead of inheriting whatever
|
||||
headroom the clamp happened to leave. It also freezes while the inverter is
|
||||
not tracking, rather than continuing to wind up against a command nothing is
|
||||
acting on. `integrator_max_w` (default `0`) governs the bound; `0` means
|
||||
"follow `max_w`", which is the existing behaviour.
|
||||
|
||||
Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep
|
||||
against the previous control law confirms it decides identically at
|
||||
`integrator_max_w: 0`.
|
||||
|
||||
**TEL-01.** P1 meter ingestion, so a Belgian P1's two unsigned registers
|
||||
(consumption, injection) no longer need a hand-written signed template
|
||||
sensor: the subtraction moves into the add-on, done once and tested. Two
|
||||
transports, chosen with the new `meter_source` option: `ha_dsmr` subscribes
|
||||
to the DSMR integration over the HA WebSocket, `mqtt_p1` reads a topic.
|
||||
Defaults to `off`, which keeps the existing `meter_entity` path untouched -
|
||||
nothing changes for an install that does not opt in.
|
||||
|
||||
Enabling it publishes `sensor.p1_sample_age_s`: seconds since the newest
|
||||
accepted telegram, recomputed against the clock and republished roughly once
|
||||
a second rather than only when a telegram lands. That is deliberate - Home
|
||||
Assistant only pushes a state on change, so a meter sitting at a genuinely
|
||||
constant reading would otherwise look identical to a dead one. Watching the
|
||||
age instead means a frozen meter shows a climbing age, not a flat line. The
|
||||
firmware watchdog subscribes to this exact entity id.
|
||||
|
||||
Known limits, both already in DOCS.md: on `mqtt_p1`, a bridge stuck
|
||||
republishing its last telegram still "arrives", so the age cannot detect
|
||||
that particular failure - prefer `ha_dsmr` where both are available. And a
|
||||
dead P1 meter takes 45 s to reach 0 W commanded (30 s for `meter_max_age_s`
|
||||
to call the reading stale, then 15 s of `stale_input_s` on top), which is
|
||||
`meter_max_age_s` and `stale_input_s` stacking, not either one alone.
|
||||
|
||||
## 0.2.1
|
||||
|
||||
`target_grid_w` (default -10 W): what the meter should rest at. The deadband
|
||||
|
||||
+229
-26
@@ -24,6 +24,9 @@ The inverter **holds its last command forever** — it has no meter-timeout. So:
|
||||
commanding it.
|
||||
- This add-on commands 0 W when its inputs go missing, when you stop control,
|
||||
and when it shuts down.
|
||||
- This add-on commands 0 W **and latches there** if what it is commanding and
|
||||
what the meter reads point opposite ways for three minutes — see "The
|
||||
sign-disagreement failsafe" below.
|
||||
- The **optional RS485 e-stop** is the only thing that covers this machine
|
||||
dying. Without it, a failed host leaves the battery latched at its last
|
||||
command until someone intervenes.
|
||||
@@ -51,21 +54,67 @@ phase having charged nothing.
|
||||
### P1 meter ingestion
|
||||
|
||||
`meter_entity` above expects one signed sensor, which usually means a template
|
||||
someone wrote by hand. A Belgian P1 meter does not publish one: it publishes two
|
||||
**unsigned** registers, consumption and injection. Setting `meter_source` moves
|
||||
that subtraction into the add-on, where it is done once and tested, and replaces
|
||||
`meter_entity` entirely.
|
||||
someone wrote by hand. Setting `meter_source` moves the whole derivation into
|
||||
the add-on, where it is done once and tested, and replaces `meter_entity`
|
||||
entirely.
|
||||
|
||||
Which mode you want depends on what your P1 reader publishes, and there are two
|
||||
shapes in the wild:
|
||||
|
||||
- **Two unsigned registers**, consumption and injection, which is what a Belgian
|
||||
P1 read over DSMR gives you → `ha_dsmr`, or `mqtt_p1` for a bridge. The add-on
|
||||
subtracts them.
|
||||
- **One signed figure**, positive = import and negative = export, which is what
|
||||
a HomeWizard P1 gives you (`sensor.p1_meter_active_power`) → `ha_signed`. The
|
||||
add-on splits it. `ha_dsmr` **cannot** read this: it wants two registers and
|
||||
rejects a negative one outright, which is every exporting telegram.
|
||||
|
||||
Either way, do not build the missing shape out of template sensors. The point of
|
||||
`meter_source` is that the sign convention is derived in one tested place rather
|
||||
than in YAML nobody reviews underneath a safety input.
|
||||
|
||||
> ✅ **If your meter is a HomeWizard P1, use `homewizard_local`, not
|
||||
> `ha_signed`.** It reads the same meter and produces the same numbers, but it
|
||||
> polls the meter directly instead of watching a Home Assistant entity — and
|
||||
> that is the difference between an age sensor a watchdog can threshold and one
|
||||
> it cannot. See "`sensor.p1_sample_age_s`" below; `ha_signed` remains for
|
||||
> installs where the meter is only reachable through Home Assistant.
|
||||
|
||||
> ⚠️ **`ha_dsmr` and `mqtt_p1` have never processed a telegram from real
|
||||
> hardware.** No meter in this installation uses either one. Both were written
|
||||
> to the assumption in `specs.md` §5.2 that a Belgian P1 exposes two unsigned
|
||||
> registers, and the meter actually fitted here does not — it is the HomeWizard
|
||||
> P1 that `ha_signed` reads. They are covered by the unit checks in `test_p1.py`
|
||||
> and by an end-to-end test against a fake Home Assistant, and nothing more.
|
||||
>
|
||||
> This is recorded because the realistic way it bites is someone debugging a
|
||||
> meter problem months from now treating those two paths as proven and looking
|
||||
> for the fault elsewhere. If you are the first person to point one at a real
|
||||
> meter, expect to find something, and please update this note when you do.
|
||||
|
||||
| option | default | meaning |
|
||||
|---|---|---|
|
||||
| `meter_source` | `off` | `off` keeps `meter_entity`. `ha_dsmr` subscribes to the DSMR integration over the HA WebSocket; `mqtt_p1` reads a topic |
|
||||
| `meter_source` | `off` | `off` keeps `meter_entity`. `ha_dsmr` subscribes to the DSMR integration over the HA WebSocket; `mqtt_p1` reads a topic; `ha_signed` subscribes to one signed entity over the HA WebSocket; `homewizard_local` polls a HomeWizard P1's own local API, bypassing Home Assistant |
|
||||
| `meter_phases` | 1 | 1 or 3. Must match the telegram, or every telegram is rejected and logged |
|
||||
| `meter_max_age_s` | 30 | Beyond this the reading is stale and grid power reads as *missing*. On its own it does **not** command 0 W — see the timing note below. It is also the longest a reading is held forward into the 15-minute average |
|
||||
| `meter_poll_s` | 5 | `homewizard_local` only. Seconds between polls. **Must be well under `meter_max_age_s`** — see below |
|
||||
| `p1_host` | | `homewizard_local` only. The meter's own address, `host` or `host:port` (e.g. `192.168.2.250`) |
|
||||
| `meter_mqtt_topic` | | `mqtt_p1` only |
|
||||
| `p1_import_entity` | | The **unsigned** consumption sensor. Do not point this at a signed template |
|
||||
| `p1_export_entity` | | The **unsigned** injection sensor |
|
||||
| `p1_phase_import_entities` | `[]` | L1..L3, in order. Needed for the capacity-tariff peak on a three-phase connection |
|
||||
| `p1_phase_export_entities` | `[]` | L1..L3, in order |
|
||||
| `p1_net_entity` | | `ha_signed` only. The **signed** net-power sensor: `+` import, `-` export |
|
||||
| `p1_phase_net_entities` | `[]` | `ha_signed` only. L1..L3, in order, each signed the same way. Needed for the capacity-tariff peak on a three-phase connection. **The list length must equal `meter_phases`** |
|
||||
|
||||
Both per-phase lists are checked against `meter_phases` **once at startup**: a
|
||||
list of the wrong length disables P1 ingestion with an error in the log, rather
|
||||
than letting every telegram fail its phase-count check one at a time. Leaving
|
||||
the list empty is fine and is not an error — you simply get no per-phase
|
||||
figures, and therefore no capacity-tariff peak. On a three-phase connection
|
||||
that is a much bigger omission than it looks: on a surveyed reading here the
|
||||
phases carried 2769 W of import while the connection netted 187 W, so the
|
||||
billed quantity is understated roughly fifteenfold if the phases are missing.
|
||||
|
||||
#### How long a dead meter takes to reach 0 W
|
||||
|
||||
@@ -106,6 +155,55 @@ tested, and guessing a key here means guessing a kilowatt:
|
||||
it is present it is used for the age, which is what stops a retained message
|
||||
replayed on reconnect from presenting a ten-minute-old reading as current.
|
||||
|
||||
#### `homewizard_local` — polling the meter instead of Home Assistant
|
||||
|
||||
Set `p1_host` to the meter's address and the add-on does `GET /api/v1/data` on
|
||||
it every `meter_poll_s` seconds, reading `active_power_w` (signed, same
|
||||
convention as `ha_signed`) and the three `active_power_l{1,2,3}_w` fields. Home
|
||||
Assistant is not involved: no entity, no WebSocket, no integration to
|
||||
mis-configure. Per-phase figures are used only when the meter serves all
|
||||
`meter_phases` of them — a single-phase meter returns `null` for L2/L3, and the
|
||||
connection-level reading is still accepted on its own.
|
||||
|
||||
**Why this mode exists:** every HTTP response is an *arrival*. The meter
|
||||
answered, now, with its current reading — whether or not the number moved. That
|
||||
is the signal `sensor.p1_sample_age_s` needs and the one Home Assistant cannot
|
||||
give it at all (see the note below). It is also simply fewer moving parts: the
|
||||
five-second cadence is the meter's own, rather than an integration's polling of
|
||||
it re-published as a state change.
|
||||
|
||||
**Cadence.** The age is never fresher than the poll interval, so:
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| meter's own update rate | ~5.0 s (measured 4.97 s) |
|
||||
| `meter_poll_s` default | 5 s — nothing to gain below the meter's own rate |
|
||||
| `meter_max_age_s` default | 30 s, i.e. six polls of headroom |
|
||||
| `meter_poll_s >= meter_max_age_s` | **refused at startup** — every reading would be stale before its successor arrived |
|
||||
| `meter_poll_s > meter_max_age_s / 2` | warned — one missed poll makes the reading stale |
|
||||
|
||||
A failed poll — timeout, connection refused, non-200, unparseable body — is a
|
||||
**missing** reading. It submits nothing, so the reading does not become 0 W, the
|
||||
last good value and its timestamp are left alone, and the age goes on climbing.
|
||||
That is exactly what a dead meter should look like.
|
||||
|
||||
**What it still cannot see: a frozen meter.** A meter that answers `200 OK`
|
||||
forever with a stale number is arriving, so no arrival detector — this one
|
||||
included — can tell it from a healthy one. The local API does expose the raw
|
||||
material the HA path never had (the `total_power_*_kwh` registers stop
|
||||
advancing), and the transport tracks it as `unchanged_s`, but it is deliberately
|
||||
*not* folded into the age and *not* thresholded: this controller regulates grid
|
||||
power toward ~0 W, and at a converged −10 W the export register needs six
|
||||
minutes to move by its 1 Wh resolution while the power figure legitimately
|
||||
repeats. Thresholding that at 30 s would rebuild the false-trip limit cycle at
|
||||
the exact operating point the controller aims for. Freeze detection is a
|
||||
separate problem and needs the low-power case solved first.
|
||||
|
||||
You read it yourself instead: the add-on's status page shows it on the P1 line,
|
||||
as `… 4 rejected, measurement unchanged for 312 s`. On a house drawing real
|
||||
power that figure stays in the seconds; minutes of it while the load is clearly
|
||||
not near zero is the meter to go and look at.
|
||||
|
||||
#### `sensor.p1_sample_age_s`
|
||||
|
||||
Published over MQTT discovery whenever a broker is available: **seconds since the
|
||||
@@ -123,13 +221,48 @@ The entity is only created when `meter_source` is not `off`. With P1 ingestion
|
||||
disabled there is nothing feeding it, and an age sensor climbing with no ingester
|
||||
behind it would trip the firmware watchdog on a system that is working fine.
|
||||
|
||||
> **Known limit, `mqtt_p1` only.** The age measures *arrival*, not change. On the
|
||||
> `ha_dsmr` path that is exactly right: a frozen meter emits no `state_changed`,
|
||||
> so nothing arrives and the age climbs. On the MQTT path a bridge that is stuck
|
||||
> republishing its last telegram keeps arriving, so the age stays near zero and a
|
||||
> frozen meter still looks fresh. Detecting *that* needs a change-detector rather
|
||||
> than an arrival-detector, and it is not in this version. Prefer `ha_dsmr` where
|
||||
> both are available.
|
||||
> **Known limit, `mqtt_p1`.** The age measures *arrival*. On the MQTT path a
|
||||
> bridge that is stuck republishing its last telegram keeps arriving, so the age
|
||||
> stays near zero and a frozen meter still looks fresh. Detecting *that* needs a
|
||||
> change-detector rather than an arrival-detector, and it is not in this version.
|
||||
|
||||
> ⚠️ **Known limit, `ha_signed` — do not drive a watchdog off this age yet.**
|
||||
> On the HA WebSocket paths the age is stamped when a `state_changed` arrives,
|
||||
> which means it measures *time since the value last changed*, not time since
|
||||
> the meter last reported. Home Assistant offers nothing better: a repeated
|
||||
> reading produces no `state_changed`, does **not** advance `last_reported` on
|
||||
> either the REST or the WebSocket serialiser, and `state_reported` cannot be
|
||||
> subscribed to over the WebSocket at all (`Event filter is required for event
|
||||
> state_reported`). All three measured on the ENV-01 rig against the real
|
||||
> HomeWizard integration with the meter frozen: 0 `state_changed` in 70 s and no
|
||||
> timestamp movement anywhere.
|
||||
>
|
||||
> `ha_dsmr` mostly escapes this because a DSMR telegram updates several entities
|
||||
> and something in the set almost always moves. **`ha_signed` has exactly one
|
||||
> entity, so a healthy meter under a flat load is indistinguishable from a dead
|
||||
> one.** This is not hypothetical: in our own captures
|
||||
> (`sim/scenarios/ha-p1_meter_active_power-2026-08-20.json`) the real house meter
|
||||
> went **42.2 s and 97.0 s** between changes, and 23 Aug peaks at 29.1 s — all
|
||||
> past the default `meter_max_age_s` of 30.
|
||||
>
|
||||
> So `sensor.p1_sample_age_s` on `ha_signed` is safe to *read*, and it is
|
||||
> correct whenever the value is moving, but it must not yet be thresholded by
|
||||
> the ESP32 stale-input watchdog: a quiet house would trip the battery to 0 W.
|
||||
> Raising `meter_max_age_s` is **not** the fix — the two conditions produce an
|
||||
> identical signal, so a bigger number only chooses which of the two errors you
|
||||
> get. The real fix is an arrival stamp the meter itself provides — and that now
|
||||
> exists: **`meter_source: homewizard_local`**. If you have a HomeWizard P1,
|
||||
> switch to it. If your meter is only reachable through Home Assistant, this
|
||||
> limit still applies to you and the watchdog threshold still must not be armed.
|
||||
|
||||
**Where the age is trustworthy:**
|
||||
|
||||
| mode | the age measures | safe to threshold from firmware |
|
||||
|---|---|---|
|
||||
| `homewizard_local` | time since the meter **answered** | **yes** — every HTTP response is an arrival |
|
||||
| `ha_dsmr` | time since one of several entities changed | no — statistically usually fine, which is a masked bug, not an absent one |
|
||||
| `ha_signed` | time since the one entity changed | **no** — see above |
|
||||
| `mqtt_p1` | time since a message arrived | arrivals yes, but a stuck bridge republishing keeps arriving |
|
||||
|
||||
### Control
|
||||
|
||||
@@ -142,11 +275,60 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
|
||||
| `step_w` | 10 | Quantisation |
|
||||
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one meter update or `cycle_floor_s`, whichever comes first - see the note below. **Do not set to 1** |
|
||||
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
|
||||
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
|
||||
| `cycle_floor_s` | 15 | The longest the loop may go without evaluating. A deadline on the gap between cycles, reset by every cycle — on a healthy meter it never elapses and changes nothing. Raise it only if your meter is slower than ~10 s; it must stay under `meter_max_age_s`, past which there is no reading to evaluate anyway |
|
||||
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
| `sign_disagree_w` | 300 | Both the command and the meter must exceed this before a sign difference counts. Must stay **below `max_w`** or the watchdog can never fire, and the add-on refuses to start |
|
||||
| `sign_disagree_s` | 180 | How long they must stay opposed, continuously, before the failsafe trips |
|
||||
|
||||
#### The sign-disagreement failsafe
|
||||
|
||||
If the setpoint this add-on is emitting and the grid figure it is regulating on
|
||||
point **opposite ways** — charging the battery while the house imports, or
|
||||
discharging it while the house exports — with both over `sign_disagree_w`, for
|
||||
`sign_disagree_s` **continuously**, the add-on commands **0 W** and holds it
|
||||
there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
|
||||
**It does not clear itself.** Pressing *Start / stop control* twice clears it.
|
||||
That is deliberate: commanding 0 W removes the command side of the comparison,
|
||||
so the disagreement always vanishes the instant the trip works, and a watchdog
|
||||
that took that as proof the fault was over would hand the inverter straight back
|
||||
to the loop that was driving the wrong way.
|
||||
|
||||
**What it is for.** This is a loop-integrity check: it asks whether the loop's
|
||||
output direction still matches the input state it was regulating. It catches a
|
||||
polarity error anywhere between the meter and the wire, and an integrator so far
|
||||
wound up that unwinding takes minutes. It is the check that would have caught all
|
||||
four episodes of 2026-08-20, when a commercial controller charged the battery out
|
||||
of the grid, four times, for up to 77 minutes at a time.
|
||||
|
||||
**What it is not for.** It does not detect an inverter that acts opposite to what
|
||||
it was told — that moves the meter *further* the same way, so command and meter
|
||||
agree while everything runs away. That is the saturation freeze's job
|
||||
(`saturation_w` / `saturation_cycles`), which compares the command against the
|
||||
battery's actual power. The two checks are complementary and neither replaces the
|
||||
other.
|
||||
|
||||
**Why it will not false-trip on ordinary operation.** A battery that refuses a
|
||||
command (empty, full, standby) leaves the meter where it was, so command and
|
||||
meter agree. A frozen meter drives the loop into agreeing with it. Around the
|
||||
resting point both signals are inside the 300 W gate, so the deadband can never
|
||||
produce one. A load step does flip the meter's sign before the loop catches up —
|
||||
measured on a full captured day, the longest such crossing is 30 s, against a
|
||||
180 s window. And the watchdog is **disarmed whenever the grid-following loop is
|
||||
not what is driving**: a maintenance grid charge opposes the meter by design and
|
||||
must not be mistaken for a fault.
|
||||
|
||||
Both numbers are measured rather than chosen, and are exposed only because the
|
||||
ticket requires defaults rather than constants. On the captured healthy day sign
|
||||
agreement is 92.9 %; on the four captured fault episodes it is 0.3 %, 0.9 %,
|
||||
10.5 % and 0.0 %. There is no reason to move either value without a capture that
|
||||
says so.
|
||||
|
||||
#### Saturation is counted in cycles, not seconds
|
||||
|
||||
@@ -154,22 +336,43 @@ The specification states the saturation window as **"> 10 s"**. This add-on coun
|
||||
**cycles** instead, and that is a deliberate, accepted deviation rather than an
|
||||
oversight - the acceptance criterion is not met as literally written.
|
||||
|
||||
A cycle here is one *changed* meter reading: the controller only runs the loop when the
|
||||
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
|
||||
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
|
||||
window** - a meter that repeats the same value stalls the counter for as long as it
|
||||
repeats.
|
||||
A cycle here is one meter update **or `cycle_floor_s` elapsing, whichever comes
|
||||
first**. At the reference P1's ~5 s update rate the default of 3 cycles is usually
|
||||
around 15 s, and the worst case is bounded at `3 x cycle_floor_s` = 45 s. It is still
|
||||
not the 10 s the specification asks for, so the deviation stands - but it is now a
|
||||
bounded number rather than an open one.
|
||||
|
||||
Two reasons that is acceptable:
|
||||
⚠️ **This passage used to say something different, and the second half of it was
|
||||
wrong.** Until SAFETY-12 the loop ran only when the meter value *changed*, so a meter
|
||||
that repeated a value stalled the counter for as long as it repeated, with no upper
|
||||
bound at all. That was defended here on the grounds that "a stalled counter is a
|
||||
detection-latency limit and not a runaway risk - the condition that stalls it stops the
|
||||
whole loop, so nothing accumulates while it is stalled". That argument covers
|
||||
**integrator windup and nothing else**. The hazard it misses is **staleness**: while the
|
||||
loop was stopped the heartbeat kept re-emitting the last command and the firmware kept
|
||||
putting it on the wire every 2 s, so a command computed from an old reading went on
|
||||
being executed through a real load change, with every indicator reading healthy.
|
||||
Measured on the rig during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals,
|
||||
zero control cycles.
|
||||
|
||||
- the control law is a pure function with no clock, which is what makes it testable
|
||||
without hardware, and a seconds-based window would have to live in the controller;
|
||||
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
|
||||
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
|
||||
while it is stalled.
|
||||
The half that survives is the first one: the control law is still a pure function with
|
||||
no clock, and the wall-clock window still lives in `Controller`, which has one - see
|
||||
`run_control()`. What changed is that the controller now enforces a floor on the gap
|
||||
between cycles, so `saturation_cycles` finally means a bounded number of seconds.
|
||||
|
||||
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
|
||||
and treat the figure as "N meter updates" rather than "N seconds".
|
||||
If a tighter window matters on your site, lower `cycle_floor_s` (not below your meter's
|
||||
update interval, or the floor starts firing on a healthy meter) or raise
|
||||
`saturation_cycles` for a fast meter.
|
||||
|
||||
**This is not a freeze detector, and it deliberately cannot be one.** Nothing here
|
||||
decides whether a repeated reading is true — see `unchanged_s` in the meter section for
|
||||
why no threshold on that is safe at the converged operating point. The floor only stops
|
||||
"the number is the same" from meaning "do not think". The consequence is worth stating
|
||||
plainly: against a meter that is genuinely frozen at a wrong value, the loop will now
|
||||
correct toward that wrong value instead of holding a stale command. It is bounded by
|
||||
`max_w`, the arbiter and the device rating, and it is the same thing that already
|
||||
happened to a lying meter whose value merely jittered — bit-exact repetition was never a
|
||||
safety property.
|
||||
|
||||
#### Why `target_grid_w` is not zero
|
||||
|
||||
|
||||
@@ -95,19 +95,23 @@ def compute(
|
||||
# lets slew be larger than saturation_w.
|
||||
#
|
||||
# The spec states this window twice and differently: "> 10 s" (§11.2) and
|
||||
# "3 samples" (§10.3). This counts CYCLES, and a cycle is not a unit of
|
||||
# time: run_control() calls cycle() only when the meter value CHANGES
|
||||
# (`if self.grid != last_grid`), so three cycles is three distinct meter
|
||||
# readings and nothing more. At the reference P1's ~5 s update rate that is
|
||||
# usually ~15 s, but there is no upper bound on it - a meter that repeats a
|
||||
# value stalls the counter.
|
||||
# "3 samples" (§10.3). This counts CYCLES, and a cycle is still not a unit
|
||||
# of time - but it is now a BOUNDED one. run_control() runs a cycle on a
|
||||
# changed meter value OR on `cycle_floor_s` elapsing, whichever comes first
|
||||
# (SAFETY-12), so three cycles is at most 3 x cycle_floor_s = 45 s at the
|
||||
# defaults, and usually ~15 s at the reference P1's ~5 s update rate.
|
||||
#
|
||||
# That is a detection-latency limit, not a windup hazard: the same
|
||||
# condition that stalls the counter stalls the whole loop, so nothing
|
||||
# accumulates in the meantime either. If a wall-clock window is ever
|
||||
# required, it belongs in Controller (which has a clock) and not here.
|
||||
# ponytail: this function is worth keeping clockless; the ceiling is that
|
||||
# saturation_cycles cannot express a guaranteed number of seconds.
|
||||
# ⚠️ THIS COMMENT USED TO CLAIM there was no upper bound and that it did not
|
||||
# matter, "because the same condition that stalls the counter stalls the
|
||||
# whole loop, so nothing accumulates in the meantime". The first clause was
|
||||
# true and the second was the bug: a stalled loop does not stop commanding,
|
||||
# it goes on emitting its last command through the heartbeat. Windup was
|
||||
# never the hazard; staleness was.
|
||||
#
|
||||
# The wall-clock window lives in Controller, which has a clock, exactly as
|
||||
# this comment always said it should. ponytail: this function stays
|
||||
# clockless; the remaining ceiling is that saturation_cycles expresses a
|
||||
# bound in seconds rather than an exact number of them.
|
||||
saturated_now = abs(prev_w - actual_w) > tuning.saturation_w
|
||||
sat_count = min(sat_count + 1, 10) if saturated_now else 0
|
||||
frozen = sat_count >= tuning.saturation_cycles
|
||||
|
||||
+269
-14
@@ -40,6 +40,8 @@ from .hass import HomeAssistant
|
||||
from .maintenance import IDLE, MaintConfig, Maintenance
|
||||
from .mqtt import MqttPublisher
|
||||
from .p1 import P1Ingest, build_source, is_enabled
|
||||
from .validate import ConfigRefused, refuse, validate_startup_config
|
||||
from .watchdog import SignWatchdog, SignWatchdogConfig
|
||||
from . import web
|
||||
|
||||
OPTIONS_PATH = "/data/options.json"
|
||||
@@ -56,11 +58,22 @@ def load_options() -> dict:
|
||||
|
||||
|
||||
class Controller:
|
||||
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub):
|
||||
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub, *, stop):
|
||||
self.o = opts
|
||||
self.hass = hass
|
||||
self.store = store
|
||||
self.mqtt = mqtt_pub
|
||||
# ⚠️ REQUIRED, AND KEYWORD-ONLY, AFTER A REVIEW CATCH. This started life
|
||||
# as `stop=None`, which made a Controller that CANNOT STOP ITSELF the
|
||||
# default one. On the late-refusal path in run_control() that default
|
||||
# meant: log the banner, return, and leave the process alive forever
|
||||
# with no control loop, no exit and no further output - the exact
|
||||
# "inert but looks healthy" failure this whole module exists to refuse.
|
||||
# amain() always passed a real Event, so it was latent, but test_p1.py
|
||||
# was already constructing Controllers without one. No default now, so
|
||||
# the broken shape does not typecheck.
|
||||
self.stop_event = stop
|
||||
self.refused: list[str] | None = None
|
||||
|
||||
self.tuning = Tuning(
|
||||
gain=float(opts.get("gain", 0.6)),
|
||||
@@ -91,12 +104,22 @@ class Controller:
|
||||
store,
|
||||
)
|
||||
|
||||
# SAFETY-02. One instance, one actuator, one cadence - see watchdog.py.
|
||||
self.sign_wd = SignWatchdog(SignWatchdogConfig(
|
||||
min_w=float(opts.get("sign_disagree_w", 300)),
|
||||
hold_s=float(opts.get("sign_disagree_s", 180)),
|
||||
))
|
||||
|
||||
# P1 ingestion (TEL-01). `meter_source: off` keeps the original
|
||||
# single-entity meter_entity path, so an existing install is unchanged
|
||||
# until it opts in.
|
||||
self.p1 = P1Ingest(phases=int(opts.get("meter_phases", 1)),
|
||||
max_age_s=float(opts.get("meter_max_age_s", 30)))
|
||||
self.p1_enabled = is_enabled(opts)
|
||||
# Set by amain() once the transport is built, so the status page can show
|
||||
# what only the transport knows (homewizard_local's unchanged_s). Stays
|
||||
# None when P1 is off, or under a transport that has no such counter.
|
||||
self.p1_source = None
|
||||
|
||||
# live state
|
||||
self.auto = bool(store.data.get("auto", opts.get("auto_start", False)))
|
||||
@@ -104,6 +127,11 @@ class Controller:
|
||||
self.sat_count = 0
|
||||
self.i_w = 0.0 # the loop's integrator, carried between cycles
|
||||
self.loop_w = None # what the loop asked for last cycle, or None
|
||||
# Did the grid-following loop actually win the LAST arbitration? That is
|
||||
# the question SAFETY-02 has to ask about the command standing on the
|
||||
# wire right now, so it is recorded when the arbitration happens rather
|
||||
# than re-derived a cycle later. Starts False: nothing is on the wire.
|
||||
self.following = False
|
||||
self.reason = "starting"
|
||||
self.grid = self.soc = self.batt = None
|
||||
self.peak_fc = None
|
||||
@@ -198,8 +226,29 @@ class Controller:
|
||||
for msg in result.events:
|
||||
self.log_event(msg)
|
||||
|
||||
# --- SAFETY-02, and it runs BEFORE the early return below -------------
|
||||
# ⚠️ ORDER MATTERS HERE. If this were evaluated after the "inputs missing
|
||||
# but not yet stale" hold, a run of held cycles would leave
|
||||
# `disagree_since` untouched across the gap and the timer would resume
|
||||
# from a start time that predates it. It is evaluated every cycle,
|
||||
# unconditionally, so a missing meter CLEARS the window - see watchdog.py.
|
||||
#
|
||||
# The value compared is the command STANDING ON THE WIRE, which is what
|
||||
# this cycle's fresh meter reading is a response to. `last_write` is that
|
||||
# value after the device clamp and confirmed accepted; `target` covers
|
||||
# the case where nothing has been written yet (and, deliberately, the
|
||||
# case where the last write was REJECTED - the inverter is then still
|
||||
# latched on `last_write`, which is exactly what `last_write` holds).
|
||||
was_tripped = self.sign_wd.tripped
|
||||
standing = self.last_write if self.last_write is not None else self.target
|
||||
if self.sign_wd.evaluate(standing, self.grid, self.following, now) \
|
||||
and not was_tripped:
|
||||
self.log_event("FAILSAFE " + self.sign_wd.reason)
|
||||
_LOG.error("SAFETY-02 TRIPPED - %s. Commanding 0 W and holding it "
|
||||
"until control is started again.", self.sign_wd.reason)
|
||||
|
||||
stale_after = float(self.o.get("stale_input_s", 15))
|
||||
if not self.inputs_ok:
|
||||
if not self.inputs_ok and not self.sign_wd.tripped:
|
||||
bad_for = (now - self.inputs_bad_since).total_seconds() if self.inputs_bad_since else 0.0
|
||||
if bad_for < stale_after:
|
||||
# A single missed poll is not a fault. Hold, keep the heartbeat
|
||||
@@ -219,6 +268,16 @@ class Controller:
|
||||
claims.append(Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"))
|
||||
|
||||
# --- safety stops ----------------------------------------------------
|
||||
# ⚠️ SAFETY-02 is claimed FIRST and unconditionally while latched. It is
|
||||
# a SET at P_SAFETY, so it outranks maintenance, peak shaving and the
|
||||
# loop alike - a controller pushing power the wrong way is wrong
|
||||
# whatever it thinks it is doing. Re-filed EVERY cycle: claims are not
|
||||
# sticky, and one filed once would lapse the next cycle and hand the
|
||||
# actuator silently back to the loop that was driving the wrong way.
|
||||
if self.sign_wd.tripped:
|
||||
claims.append(Claim.set("failsafe", P_SAFETY, 0.0,
|
||||
"sign disagreement"))
|
||||
|
||||
if not self.auto:
|
||||
claims.append(Claim.set("safety", P_SAFETY, 0.0, "stopped"))
|
||||
elif not self.inputs_ok:
|
||||
@@ -290,6 +349,28 @@ class Controller:
|
||||
resolution = resolve(claims)
|
||||
if resolution.contradiction:
|
||||
self.log_event("ARBITER CONTRADICTION - commanding 0 W, see the log")
|
||||
# --- SAFETY-02's arming gate ------------------------------------------
|
||||
# Was the number about to go on the wire chosen by the grid-following
|
||||
# loop, or by a strategy that commands against the meter on purpose?
|
||||
# Only the former is expected to agree in sign with P1. See gate 1 in
|
||||
# watchdog.py - without this, every maintenance grid charge trips the
|
||||
# failsafe within three minutes of starting.
|
||||
#
|
||||
# ⚠️ "THE LOOP WON" IS NOT ENOUGH, and the difference is a whole class of
|
||||
# false trip. A LIMIT claim can survive the loop winning and still
|
||||
# replace its number: maintenance's charge-only shaping is
|
||||
# `hi = -charge_w`, so the loop can ask for +500 W of discharge, win the
|
||||
# arbitration, and have the emitted value come out at -2500 W of grid
|
||||
# charge. Winner says "loop"; the wire carries maintenance's intent. So
|
||||
# the test is on the NUMBER, not on the name: the loop is following only
|
||||
# while the emitted value points the way the loop asked and is no larger
|
||||
# than it asked - i.e. limits reduced it, they did not redirect it.
|
||||
# Zero on either side falls out as not-following, which costs nothing:
|
||||
# a 0 W command cannot be a wrong-direction command.
|
||||
asked = self.loop_w
|
||||
self.following = (resolution.winner == "loop" and asked is not None
|
||||
and resolution.target_w * asked > 0
|
||||
and abs(resolution.target_w) <= abs(asked))
|
||||
self.target = resolution.target_w
|
||||
self.reason = resolution.explain()
|
||||
await self.write_setpoint(self.target)
|
||||
@@ -299,19 +380,112 @@ class Controller:
|
||||
entity = self.o.get("setpoint_entity", "")
|
||||
if entity:
|
||||
self.dev_min, self.dev_max, _ = await self.hass.limits(entity)
|
||||
if self.dev_max is not None and self.tuning.max_w > self.dev_max:
|
||||
self.log_event(
|
||||
f"clamp {self.tuning.max_w:.0f} W exceeds the device maximum "
|
||||
f"{self.dev_max:.0f} W - the device wins")
|
||||
# ⚠️ THIS USED TO WARN AND CARRY ON, and that was the bug CFG-01
|
||||
# exists to remove: a max_w above the device's rating meant
|
||||
# write_setpoint() silently clamped and the configured ceiling was
|
||||
# never the real one.
|
||||
#
|
||||
# amain() already ran this gate before anything started. It runs
|
||||
# AGAIN here for one case the gate cannot cover: ESPHome is often
|
||||
# not up yet when the add-on boots, so hass.limits() returned
|
||||
# (None, None) and the range checks were skipped rather than
|
||||
# guessed at. This is the first moment the device's real rating is
|
||||
# known. If it conflicts, refuse now - stopping deterministically
|
||||
# through the normal shutdown, which commands 0 W on the way out.
|
||||
problems = validate_startup_config(self.o, self.dev_min, self.dev_max)
|
||||
if problems:
|
||||
refuse(problems)
|
||||
self.refused = problems
|
||||
self.log_event("REFUSED: " + problems[0])
|
||||
# Signal, then return WITHOUT entering the loop. amain() wakes
|
||||
# on this, runs the normal wind-down (which commands 0 W) and
|
||||
# re-raises ConfigRefused afterwards, so the exit code is 78 and
|
||||
# the inverter is left at zero rather than latched.
|
||||
self.stop_event.set()
|
||||
return
|
||||
|
||||
last_grid = object()
|
||||
heartbeat = float(self.o.get("heartbeat_s", 10))
|
||||
last_beat = 0.0
|
||||
# ⚠️ SAFETY-12. The floor is a DEADLINE ON THE GAP BETWEEN CYCLES, not a
|
||||
# second scheduler running alongside the arrival trigger. Every cycle
|
||||
# resets it, whichever trigger fired, so on a healthy changing meter it
|
||||
# never elapses and not one existing cycle moves - and therefore no
|
||||
# change to the per-cycle gain the tuning was measured against.
|
||||
#
|
||||
# That is true twice over, and the second reason is the sturdier one:
|
||||
# the combined cycle rate is max(arrival rate, 1/floor), never the sum.
|
||||
# At the defaults 1/15 s is strictly slower than the ~1/5 s arrival
|
||||
# rate, so even a floor that raced the arrivals could not push the loop
|
||||
# past its nominal healthy rate. The re-tune is unreachable by
|
||||
# construction, not merely by the reset. ⚠️ That argument holds only
|
||||
# while floor > the meter's update interval - which is why the schema
|
||||
# minimum of 5 s deserves the second look validate.py has not given it
|
||||
# yet: 5 s IS the reference meter's interval, i.e. the one configurable
|
||||
# value that would double the cycle rate.
|
||||
#
|
||||
# Why it has to exist, and it is not only about latency: `self.grid !=
|
||||
# last_grid` alone means a meter that repeats a value runs NO control
|
||||
# cycles at all. The heartbeat below keeps re-emitting the last command
|
||||
# and the firmware keeps putting it on the wire, so every indicator
|
||||
# reads healthy - and, worse, the `inputs missing -> 0 W` claim lives
|
||||
# INSIDE cycle(), so on a repeating meter THAT SAFETY CLAIM CANNOT FIRE.
|
||||
# Demonstrated in test_loop.py: constant meter, SoC entity dies at t=4 s,
|
||||
# and the pre-fix controller holds 220 W through the whole outage with
|
||||
# the status line still reading "loop -> 220 W". Layer 1 does not cover
|
||||
# it on a `meter_source: off` install either - no P1 age sensor is
|
||||
# published, so the firmware has nothing to veto on. Measured on the rig
|
||||
# during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals, zero
|
||||
# cycles.
|
||||
#
|
||||
# This is NOT a freeze detector, and deliberately so - see
|
||||
# HomeWizardLocalSource.unchanged_s for why one cannot be built here (at
|
||||
# the converged -10 W target a 1 Wh register needs ~6 minutes to move,
|
||||
# so any freeze threshold false-trips at the exact operating point we
|
||||
# run at). Nothing here decides whether a repeated reading is true. It
|
||||
# only stops "the number is the same" from meaning "do not think".
|
||||
#
|
||||
# ⚠️ THE 15 s DEFAULT HAS A CEILING IT DOES NOT OWN. It is under
|
||||
# validate.FIRMWARE_INGEST_VETO_S (30 s) and under meter_max_age_s on
|
||||
# purpose, so the loop re-decides at least twice inside any window in
|
||||
# which layer 1 might otherwise be the only thing deciding. If the
|
||||
# firmware's veto ever moves, this default moves with it - it is not
|
||||
# independently justified at 15.
|
||||
floor = float(self.o.get("cycle_floor_s", 15))
|
||||
last_cycle = None
|
||||
while not self.stopping:
|
||||
await self.read_inputs()
|
||||
# A cycle is one meter update, exactly as on the reference install.
|
||||
if self.grid != last_grid:
|
||||
now_mono = asyncio.get_running_loop().time()
|
||||
# A cycle is one meter update, exactly as on the reference install -
|
||||
# or the floor elapsing, whichever comes first.
|
||||
overdue = last_cycle is None or (now_mono - last_cycle) >= floor
|
||||
if self.grid != last_grid or overdue:
|
||||
last_grid = self.grid
|
||||
last_cycle = now_mono
|
||||
# ⚠️ The FULL cycle, not a degraded one. A floor cycle runs the
|
||||
# same law on the same inputs as an arrival cycle, because in P1
|
||||
# mode the freshness question is already answered upstream and
|
||||
# answered harder: past `meter_max_age_s` (30 s) p1.net_w is
|
||||
# None, which is "inputs missing", which becomes a P_SAFETY 0 W
|
||||
# claim. So a floor cycle cannot run the PI on a 60 s old
|
||||
# figure, because at 60 s there is no figure.
|
||||
#
|
||||
# ⚠️ THAT GUARANTEE IS TRANSPORT-CONDITIONAL, and saying so
|
||||
# matters more than the guarantee: with `meter_source: off`,
|
||||
# read_inputs() takes self.grid straight from hass.number() with
|
||||
# NO age gate at all, so a Home Assistant entity that has gone
|
||||
# quiet reads as a current value on that path with or without
|
||||
# this change. Running the full law is still the right choice
|
||||
# there - the alternative is a degraded second law reasoning
|
||||
# about an age nobody measured - but the floor does not make
|
||||
# that path fresh, and nothing here should be read as claiming
|
||||
# it does. And the integrator
|
||||
# advances per CYCLE, not per second (control.py), so bounding
|
||||
# the gap bounds the accumulation: at most one extra
|
||||
# gain x error per floor interval, under the same
|
||||
# integrator_max_w as every other cycle. A second, gentler
|
||||
# control law for floor cycles would be a second set of
|
||||
# dynamics nobody can test on this hardware.
|
||||
await self.cycle()
|
||||
# ⚠️ The heartbeat is not an optimisation. The ESP32 treats silence
|
||||
# longer than ~30 s as "the controller is gone" and zeroes the
|
||||
@@ -330,10 +504,18 @@ class Controller:
|
||||
"battery": self.batt,
|
||||
"soc": self.soc,
|
||||
"phase": self.maint.phase,
|
||||
"status": "running" if self.auto else "stopped",
|
||||
# ⚠️ SAFETY-02's alarm surface, and it is deliberately an existing
|
||||
# one. IF-01/IF-02 own `ems/event/failsafe` and the `failsafe active`
|
||||
# binary sensor and neither is built yet; inventing a bespoke topic
|
||||
# here would be a surface to migrate later. This sensor is already
|
||||
# discovered, already on every dashboard, and "failsafe" is
|
||||
# additive to its vocabulary rather than a change to it.
|
||||
"status": ("failsafe" if self.sign_wd.tripped
|
||||
else "running" if self.auto else "stopped"),
|
||||
}
|
||||
# ⚠️ ONLY when P1 ingestion is actually running. The ESP32's stale-input
|
||||
# watchdog subscribes to sensor.p1_sample_age_s and forces the layer-1
|
||||
# watchdog subscribes to sensor.goodwe_p1_sample_age - see the entity-id
|
||||
# note in mqtt.py; the composed name is not the object_id - and forces layer-1
|
||||
# failsafe once it reaches max_age_s. With meter_source off there is no
|
||||
# ingester feeding it, so published_age_s would be time-since-startup
|
||||
# climbing without bound - i.e. every existing install would cross the
|
||||
@@ -365,10 +547,22 @@ class Controller:
|
||||
+ (f" - last error: {self.p1.last_error}"
|
||||
if self.p1.last_error else "")})
|
||||
else:
|
||||
# ⚠️ unchanged_s is REPORTED, never thresholded and never folded
|
||||
# into the age - see HomeWizardLocalSource.unchanged_s for why
|
||||
# (at the converged -10 W this controller aims for, a 1 Wh
|
||||
# register needs ~6 minutes to move, so any limit false-trips at
|
||||
# the exact operating point we target). The whole argument for
|
||||
# leaving it unthresholded is that a human interprets it, which
|
||||
# requires a human being able to see it - so here it is. getattr:
|
||||
# only homewizard_local has one, and p1_source is None until
|
||||
# amain() builds the transport.
|
||||
unchanged = getattr(self.p1_source, "unchanged_s", None)
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"P1 meter ({o.get('meter_source')}): {self.p1.net_w:g} W, "
|
||||
f"{age:.0f} s old, {self.p1.samples} telegrams, "
|
||||
f"{self.p1.parse_errors} rejected"})
|
||||
f"{self.p1.parse_errors} rejected"
|
||||
+ (f", measurement unchanged for {unchanged:.0f} s"
|
||||
if unchanged is not None else "")})
|
||||
rows = [("battery SoC", self.soc, o.get("soc_entity")),
|
||||
("battery power", self.batt, o.get("batt_entity"))]
|
||||
if not self.p1_enabled:
|
||||
@@ -399,6 +593,22 @@ class Controller:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "last write to the inverter was REJECTED - check the log"})
|
||||
|
||||
# SAFETY-02. Reported in both states: a watchdog nobody can see is armed
|
||||
# is a watchdog nobody trusts when it fires.
|
||||
if self.sign_wd.tripped:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "SIGN-DISAGREEMENT FAILSAFE - " + self.sign_wd.reason
|
||||
+ ". The inverter is held at 0 W. Find out why the "
|
||||
"command opposed the meter before starting control "
|
||||
"again; starting clears this."})
|
||||
else:
|
||||
held = self.sign_wd.held_s
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"sign watchdog: armed (trips after "
|
||||
f"{self.sign_wd.cfg.hold_s:.0f} s opposed, both over "
|
||||
f"{self.sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {held:.0f} s now" if held else "")})
|
||||
|
||||
if not o.get("estop_fitted", False):
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "no e-stop fitted: if this host dies the battery stays "
|
||||
@@ -416,7 +626,11 @@ class Controller:
|
||||
def status_payload(self) -> dict:
|
||||
checks = self.checks()
|
||||
bad = [c for c in checks if not c["ok"] and not c["warn"]]
|
||||
if bad:
|
||||
if self.sign_wd.tripped:
|
||||
# Outranks "NOT READY": nothing is missing, something went wrong.
|
||||
level, banner = "bad", ("FAILSAFE — the command opposed the meter. "
|
||||
"Inverter held at 0 W.")
|
||||
elif bad:
|
||||
level, banner = "bad", f"NOT READY — {bad[0]['text']}"
|
||||
elif not self.auto:
|
||||
level, banner = "warn", "Stopped — inverter commanded to 0 W"
|
||||
@@ -450,6 +664,15 @@ class Controller:
|
||||
self.auto = not self.auto
|
||||
self.store.set("auto", self.auto)
|
||||
self.log_event("control started" if self.auto else "control stopped")
|
||||
if self.auto and self.sign_wd.tripped:
|
||||
# ⚠️ THE ONLY WAY OUT OF A SIGN-DISAGREEMENT TRIP, on purpose.
|
||||
# It clears on a deliberate human start, not on the condition
|
||||
# going away - the condition ALWAYS goes away, because the trip
|
||||
# commands 0 W and a 0 W command cannot disagree with anything.
|
||||
# An operator pressing start has, at minimum, looked at the
|
||||
# banner that says why.
|
||||
self.sign_wd.reset()
|
||||
self.log_event("sign-disagreement failsafe cleared by operator")
|
||||
if not self.auto:
|
||||
self.target = 0.0
|
||||
await self.write_setpoint(0.0, force=True)
|
||||
@@ -498,6 +721,26 @@ async def amain() -> None:
|
||||
except Exception as _e: # noqa: BLE001
|
||||
_LOG.error("core api probe failed: %s", _e)
|
||||
|
||||
# ⚠️ THE STARTUP GATE (CFG-01). Nothing below this line may run on a
|
||||
# configuration validate.py rejects - specs §1.5: a config the system
|
||||
# cannot honour is refused at startup, not survived at runtime.
|
||||
#
|
||||
# It sits HERE, before the broker, before the web server and before any
|
||||
# task exists, so a refusal cannot leave half a controller running with
|
||||
# a UI in front of it. Reading the device range is the one thing the
|
||||
# validator cannot do for itself; (None, None) when ESPHome has not come
|
||||
# up yet is not a refusal - run_control() re-checks once the real rating
|
||||
# is known. See validate.py for where the line is drawn and why.
|
||||
_sp = str(opts.get("setpoint_entity", "") or "").strip()
|
||||
_dev_min = _dev_max = None
|
||||
if _sp:
|
||||
_dev_min, _dev_max, _ = await hass.limits(_sp)
|
||||
_LOG.info("setpoint device %s reports range %s…%s W", _sp, _dev_min, _dev_max)
|
||||
_problems = validate_startup_config(opts, _dev_min, _dev_max)
|
||||
if _problems:
|
||||
refuse(_problems)
|
||||
raise ConfigRefused(_problems)
|
||||
|
||||
# ⚠️ Status publishing must NEVER be able to stop the controller. A
|
||||
# broken broker, a missing library, an API change in paho - all of it is
|
||||
# observability, and the battery does not care. Caught broadly and on
|
||||
@@ -523,10 +766,10 @@ async def amain() -> None:
|
||||
|
||||
pub = _NoMqtt()
|
||||
|
||||
controller = Controller(opts, hass, store, pub)
|
||||
stop = asyncio.Event()
|
||||
controller = Controller(opts, hass, store, pub, stop=stop)
|
||||
runner = await web.start(controller, port=8099)
|
||||
|
||||
stop = asyncio.Event()
|
||||
loop = asyncio.get_running_loop()
|
||||
for sig in (signal.SIGTERM, signal.SIGINT):
|
||||
with contextlib.suppress(NotImplementedError):
|
||||
@@ -540,6 +783,7 @@ async def amain() -> None:
|
||||
# unit - would be computed from a fraction of the data.
|
||||
p1_source = build_source(opts, controller.p1, session, broker)
|
||||
if p1_source is not None:
|
||||
controller.p1_source = p1_source # so checks() can report on it
|
||||
tasks.append(asyncio.create_task(p1_source.run()))
|
||||
|
||||
await stop.wait()
|
||||
@@ -552,6 +796,10 @@ async def amain() -> None:
|
||||
await task
|
||||
await runner.cleanup()
|
||||
_LOG.info("stopped")
|
||||
# The late-arriving-device refusal from run_control(). Re-raised only
|
||||
# now, so the wind-down above still ran and the inverter is at 0 W.
|
||||
if controller.refused:
|
||||
raise ConfigRefused(controller.refused)
|
||||
|
||||
|
||||
def main() -> None:
|
||||
@@ -559,6 +807,13 @@ def main() -> None:
|
||||
asyncio.run(amain())
|
||||
except KeyboardInterrupt:
|
||||
pass
|
||||
except ConfigRefused:
|
||||
# ⚠️ No traceback, on purpose. The banner refuse() already printed says
|
||||
# everything an operator needs, and a stack trace on top of it would say
|
||||
# "this crashed" - the exact confusion AC3 is about. 78 is sysexits(3)
|
||||
# EX_CONFIG, so even a script reading the exit status can tell a bad
|
||||
# config from a bug.
|
||||
raise SystemExit(78)
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
|
||||
@@ -45,13 +45,32 @@ SENSORS = [
|
||||
("soc", "goodwe_battery_soc", "Battery SoC", "%", "battery", "measurement", None),
|
||||
("phase", "goodwe_maintenance_phase", "Maintenance phase", None, None, None, "mdi:battery-sync"),
|
||||
("status", "goodwe_controller_status", "Controller status", None, None, None, "mdi:heart-pulse"),
|
||||
# ⚠️ This one deliberately breaks the goodwe_ prefix above: the entity id
|
||||
# must be exactly `sensor.p1_sample_age_s`, because SAFETY-01's firmware
|
||||
# watchdog subscribes to that literal id and the ENV-01 simulation rig
|
||||
# asserts on it. Renaming it silently disarms a safety layer. It is seconds
|
||||
# since the newest accepted P1 telegram, republished every second so that a
|
||||
# meter frozen at a constant value still shows a climbing age - which is the
|
||||
# false-trip that this entity exists to remove.
|
||||
# ⚠️ THE LIVE ENTITY IS `sensor.goodwe_p1_sample_age`, NOT what this
|
||||
# object_id spells. An earlier version of this comment said the id "must be
|
||||
# exactly sensor.p1_sample_age_s" - that name has never existed on any HA,
|
||||
# and believing it is how a safety layer gets disarmed by someone tidying up.
|
||||
#
|
||||
# On HA 2026.8 `object_id` in a discovery payload does NOT determine the
|
||||
# entity_id. HA composes it from the device name plus the entity name:
|
||||
# "GoodWe RS485 Controller" + "P1 sample age" -> sensor.goodwe_p1_sample_age.
|
||||
# Verified against the live system 2026-08-26; the firmware subscribes to
|
||||
# that composed name (goodwe-master-stage4-failsafe.yaml, homeassistant
|
||||
# sensor p1_age_s), and its own comment records that sensor.p1_sample_age_s
|
||||
# never existed.
|
||||
#
|
||||
# So: do NOT "fix" the firmware to match the object_id below, and do not
|
||||
# rename the device or this entity's friendly name - either changes the
|
||||
# composed id and silently disarms the ingest guard, because has_state()
|
||||
# simply stays false forever and nothing reports it. The firmware calls this
|
||||
# out as the failure that "FAILS SILENTLY AND LOOKS CORRECT".
|
||||
#
|
||||
# The value: seconds since the newest accepted P1 telegram, republished
|
||||
# every second so a meter frozen at a constant value still shows a climbing
|
||||
# age - the false-trip this entity exists to remove.
|
||||
#
|
||||
# ⚠️ Separately, and not fixed here: the firmware's ingest guard tests this
|
||||
# sensor's VALUE rather than its arrival, so a dead publisher freezes the
|
||||
# number and reads permanently fresh. Filed as TEL-06.
|
||||
("p1_age", "p1_sample_age_s", "P1 sample age", "s", "duration", "measurement", None),
|
||||
]
|
||||
|
||||
|
||||
+503
-7
@@ -4,13 +4,22 @@ Everything downstream trusts this module: the safety checks, the capacity-tariff
|
||||
peak, the optimizer, the control loop's sign. So three things happen here and
|
||||
nowhere else.
|
||||
|
||||
1. The IMPORT/EXPORT DERIVATION. A Belgian P1 meter exposes two UNSIGNED
|
||||
registers - consumption and injection - never one signed figure. Net power
|
||||
is `import_w - export_w`, positive = import, and that subtraction is done
|
||||
1. The IMPORT/EXPORT DERIVATION. A Belgian P1 read over DSMR exposes two
|
||||
UNSIGNED registers - consumption and injection. Net power is
|
||||
`import_w - export_w`, positive = import, and that subtraction is done
|
||||
exactly once, here (spec §5.2: "the derivation is the EMS's job, not a
|
||||
template the user has to write"). A second copy of it somewhere else is a
|
||||
second chance to invert the control loop.
|
||||
|
||||
Some P1 readers - the HomeWizard P1 among them - publish the OTHER shape:
|
||||
one SIGNED figure, positive = import, and no unsigned registers at all.
|
||||
`split_signed()` fans that back out into the same two magnitudes, so there
|
||||
is still exactly one internal representation and one sign convention. ⚠️ It
|
||||
lives here, next to the subtraction, for the same reason the subtraction
|
||||
does: the moment a user is asked to write two template sensors that split a
|
||||
signed value, the sign convention is back in unreviewed YAML underneath a
|
||||
safety input, which is precisely what §5.2 moved into the EMS.
|
||||
|
||||
2. THE INGEST TIMESTAMP. Every accepted sample is stamped on arrival. A value
|
||||
with no age is a value that cannot be trusted (§5.2), and staleness is the
|
||||
failsafe trigger (§11.2).
|
||||
@@ -47,6 +56,8 @@ _LOG = logging.getLogger("goodwe.p1")
|
||||
|
||||
SOURCE_HA = "ha_dsmr"
|
||||
SOURCE_MQTT = "mqtt_p1"
|
||||
SOURCE_HA_SIGNED = "ha_signed"
|
||||
SOURCE_HOMEWIZARD = "homewizard_local"
|
||||
|
||||
QUARTER_S = 900
|
||||
|
||||
@@ -78,7 +89,7 @@ class P1Sample:
|
||||
ingest_ts: datetime # tz-aware UTC, set at ingest
|
||||
ingest_mono: float # time.monotonic() at ingest - see age_s()
|
||||
telegram_ts: datetime | None # from the telegram, where the source has one
|
||||
source: str # SOURCE_HA | SOURCE_MQTT
|
||||
source: str # one of the SOURCE_* constants above
|
||||
import_w: float # unsigned magnitude, as the meter reports it
|
||||
export_w: float # unsigned magnitude
|
||||
net_w: float # import_w - export_w (+ import, - export)
|
||||
@@ -129,6 +140,29 @@ def _watts(value, what: str) -> float:
|
||||
return out
|
||||
|
||||
|
||||
def split_signed(net_w) -> tuple[float, float]:
|
||||
"""One signed figure -> the (import, export) magnitudes the module speaks.
|
||||
|
||||
The inverse of make_sample's subtraction, and the easy direction: no second
|
||||
register to disagree with, so there is nothing to mix a fresh reading with a
|
||||
stale one. `+` is import, `-` is export - verified in test_p1.py against real
|
||||
captured readings from this house's own meter, not against a datasheet.
|
||||
|
||||
⚠️ Exactly one of the two comes out non-zero. Splitting into `(max(v,0),
|
||||
max(-v,0))` rather than clamping keeps `import_w - export_w == v` exactly, so
|
||||
the signed value the meter published survives the round trip bit for bit -
|
||||
a control loop must not be steered by a number that changed on the way in.
|
||||
|
||||
⚠️ Validation is `_watts`, the same gate the unsigned path uses: NaN,
|
||||
infinity, non-numbers and the §20 open-question-5 unsigned-decode
|
||||
contamination (64954 for -582 W) are all refused here rather than believed.
|
||||
A signed source makes that check MORE important, not less - on this path
|
||||
64954 is not obviously wrong the way a negative "unsigned" register is.
|
||||
"""
|
||||
v = _watts(net_w, "net")
|
||||
return (v, 0.0) if v >= 0 else (0.0, -v)
|
||||
|
||||
|
||||
def make_sample(source: str, import_w, export_w, *, phases: int,
|
||||
phase_import_w=None, phase_export_w=None,
|
||||
telegram_ts: datetime | None = None,
|
||||
@@ -668,6 +702,333 @@ class MqttP1Source:
|
||||
self.ingest.reject(err)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# transport 3: Home Assistant WebSocket, one signed entity
|
||||
# --------------------------------------------------------------------------- #
|
||||
class HaSignedSource(HaDsmrSource):
|
||||
"""The same websocket, subscribed to ONE signed power entity.
|
||||
|
||||
For readers that publish net power as a single signed figure - a HomeWizard
|
||||
P1's `sensor.p1_meter_active_power`, positive = import - rather than the two
|
||||
unsigned DSMR registers. This is the meter actually installed at the house,
|
||||
and `ha_dsmr` cannot read it: it needs two registers and refuses a negative
|
||||
one outright, which is every exporting telegram.
|
||||
|
||||
⚠️ A subclass, not a copy. The connect / auth / subscribe / reconnect /
|
||||
`_absorb` machinery above is transport, not shape, and it has already been
|
||||
debugged once - notably "prime the cache from get_states but never build a
|
||||
sample out of it" and "a reconnect emits nothing". Only `_wanted` (which
|
||||
entity ids) and `build` (how they become a sample) differ, so only those two
|
||||
are overridden. Everything TEL-01 established therefore applies unchanged:
|
||||
ingest timestamping, meter_max_age_s, the clock-recomputed age sensor, and
|
||||
`unavailable` treated as a missing reading rather than 0 W.
|
||||
|
||||
⚠️ THE AGE ON THIS TRANSPORT MEASURES TIME SINCE THE VALUE CHANGED, not time
|
||||
since the meter reported, and on one entity those are very different things.
|
||||
Home Assistant offers no arrival signal for a repeated reading: it emits no
|
||||
`state_changed`, it does not advance `last_reported` on either serialiser,
|
||||
and `state_reported` cannot be subscribed to over the websocket at all
|
||||
("Event filter is required for event state_reported"). All three measured on
|
||||
the ENV-01 rig against the real HomeWizard integration with the meter frozen
|
||||
- 0 state_changed in 70 s, no timestamp movement anywhere.
|
||||
|
||||
`ha_dsmr` mostly escapes it because a DSMR telegram moves several entities at
|
||||
once. This transport has ONE, so a healthy meter under a flat load looks
|
||||
exactly like a dead one - and our own capture has the real meter going 42.2 s
|
||||
and 97.0 s between changes, both past the default max_age_s of 30. Hence
|
||||
DOCS.md: sensor.p1_sample_age_s is correct while the value moves and must not
|
||||
yet be thresholded by the firmware watchdog on this transport. Raising
|
||||
meter_max_age_s does not fix it, it only chooses which of the two errors you
|
||||
get. The fix is an arrival stamp from the meter itself - reading the
|
||||
HomeWizard local API rather than an HA entity - which is a separate ticket.
|
||||
|
||||
⚠️ The debounce is inherited but does nothing useful here, and that is fine:
|
||||
one telegram is one entity, so there is no burst of per-entity events to
|
||||
coalesce and no window in which a new reading sits beside a stale one. It
|
||||
costs one scheduled sleep per telegram at ~0.2 Hz. Left in place rather than
|
||||
special-cased, because a second code path through build() is a second place
|
||||
for the sign to go wrong.
|
||||
"""
|
||||
|
||||
def _wanted(self) -> set[str]:
|
||||
out = set()
|
||||
if self.entities.get("net"):
|
||||
out.add(self.entities["net"])
|
||||
out.update(e for e in self.entities.get("phase_net") or [] if e)
|
||||
return out
|
||||
|
||||
def build(self) -> bool:
|
||||
"""Assemble one sample from the cache. Returns True if one was accepted."""
|
||||
net_id = self.entities.get("net")
|
||||
if net_id not in self.cache:
|
||||
return False
|
||||
pn = [self.cache.get(e) for e in self.entities.get("phase_net") or []]
|
||||
if pn and None in pn:
|
||||
return False # incomplete phase set: wait, do not guess
|
||||
try:
|
||||
imp, exp = split_signed(self.cache[net_id])
|
||||
pi = pe = None
|
||||
if pn:
|
||||
# ponytail: this split is arithmetically redundant today -
|
||||
# make_sample subtracts the two lists again and does not
|
||||
# sign-check per-phase figures, so handing it the signed values
|
||||
# with a zero export list produces the identical tuple. Verified:
|
||||
# mutating it that way leaves all 174 checks green, i.e. no test
|
||||
# can tell the difference, and it is recorded here rather than
|
||||
# left as a silent equivalent mutant for the next reviewer to
|
||||
# rediscover. Kept because `phase_import_w` means a MAGNITUDE:
|
||||
# a negative in it is the double-signing that make_sample refuses
|
||||
# outright for the connection-level registers, and the day that
|
||||
# check is extended per-phase the shortcut breaks the meter, not
|
||||
# the test.
|
||||
pairs = [split_signed(v) for v in pn]
|
||||
pi = [a for a, _ in pairs]
|
||||
pe = [b for _, b in pairs]
|
||||
self.ingest.submit(make_sample(
|
||||
SOURCE_HA_SIGNED, imp, exp,
|
||||
phases=self.ingest.phases,
|
||||
phase_import_w=pi, phase_export_w=pe,
|
||||
# ⚠️ No telegram_ts, for the same reason as ha_dsmr: HA's
|
||||
# last_changed is when the VALUE changed, which on a steady meter
|
||||
# is minutes ago while the telegram is current. sensor.
|
||||
# p1_sample_age_s is what covers a genuinely frozen meter.
|
||||
))
|
||||
return True
|
||||
except P1Error as err:
|
||||
self.ingest.reject(err)
|
||||
return False
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# transport 4: the HomeWizard P1's own local API
|
||||
# --------------------------------------------------------------------------- #
|
||||
HOMEWIZARD_PATH = "/api/v1/data"
|
||||
HOMEWIZARD_PORT = 80
|
||||
|
||||
|
||||
def parse_homewizard(doc, phases: int, *, now: datetime | None = None,
|
||||
ingest_mono: float | None = None) -> P1Sample:
|
||||
"""One `GET /api/v1/data` document -> a sample. Raises P1Error.
|
||||
|
||||
The meter's own JSON, of which we read four keys:
|
||||
|
||||
{"active_power_w": -5710.0, # SIGNED, + import - export
|
||||
"active_power_l1_w": ..., "active_power_l2_w": ..., "..._l3_w": ...,
|
||||
"total_power_import_kwh": 1234.567, "total_power_export_kwh": 890.123}
|
||||
|
||||
Same shape as `ha_signed` - one signed connection figure plus signed
|
||||
per-phase figures - so it goes through the same `split_signed` and the same
|
||||
`make_sample`. Nothing about the sign convention is re-derived here.
|
||||
|
||||
⚠️ No telegram timestamp, because the API carries none, and that is correct
|
||||
rather than a gap: the document was produced by the meter in the moment it
|
||||
answered, so the ingest stamp IS the measurement time. This is the whole
|
||||
reason the transport exists - see HomeWizardLocalSource.
|
||||
|
||||
⚠️ Per-phase figures are taken only when the meter serves ALL `phases` of
|
||||
them. A single-phase HomeWizard returns `active_power_l2_w: null`, and a
|
||||
partial set must not become a fabricated tuple. Unlike the HA transports
|
||||
there is no "wait for the rest" case to worry about: every field here came
|
||||
out of ONE response, so a missing phase cannot be a stale phase, and the
|
||||
connection-level reading is still a genuine, complete measurement. Dropping
|
||||
the whole sample over an absent per-phase field would turn a healthy meter
|
||||
into a climbing age, which is the exact false-trip this ticket removes.
|
||||
"""
|
||||
if not isinstance(doc, dict):
|
||||
raise P1Error(f"meter response is not a JSON object ({type(doc).__name__})")
|
||||
|
||||
imp, exp = split_signed(doc.get("active_power_w"))
|
||||
|
||||
pi = pe = None
|
||||
# ⚠️ range(phases), not the legs the meter served: a 3-phase meter configured
|
||||
# as meter_phases: 1 yields a per-phase tuple covering ONE leg of three.
|
||||
# Control is unaffected (it uses the connection figure), but the
|
||||
# capacity-tariff peak is understated. Filed separately - not fixed here.
|
||||
legs = [doc.get(f"active_power_l{i + 1}_w") for i in range(phases)]
|
||||
if all(v is not None for v in legs):
|
||||
pairs = [split_signed(v) for v in legs]
|
||||
pi = [a for a, _ in pairs]
|
||||
pe = [b for _, b in pairs]
|
||||
|
||||
return make_sample(SOURCE_HOMEWIZARD, imp, exp, phases=phases,
|
||||
phase_import_w=pi, phase_export_w=pe,
|
||||
ingest_ts=now, ingest_mono=ingest_mono)
|
||||
|
||||
|
||||
def measurement_fingerprint(doc) -> tuple:
|
||||
"""The part of a response that a genuinely new measurement has to move.
|
||||
|
||||
Power plus both energy registers. A meter under any real load advances a
|
||||
kWh counter (1 Wh resolution: ~10 s at 350 W), so this changes even when the
|
||||
power figure happens to repeat. Used ONLY for `unchanged_s` - see there for
|
||||
why it must not be allowed anywhere near the age.
|
||||
"""
|
||||
if not isinstance(doc, dict):
|
||||
return ()
|
||||
return (doc.get("active_power_w"),
|
||||
doc.get("total_power_import_kwh"),
|
||||
doc.get("total_power_export_kwh"))
|
||||
|
||||
|
||||
class HomeWizardLocalSource:
|
||||
"""Polls the meter's own local HTTP API instead of a Home Assistant entity.
|
||||
|
||||
⚠️ THIS IS THE ONLY TRANSPORT WHOSE AGE MEASURES ARRIVAL. That is the entire
|
||||
reason it exists, and it is not an optimisation - it is the difference
|
||||
between an age sensor a firmware watchdog may threshold and one it may not.
|
||||
|
||||
Every HTTP response is a genuine arrival: the meter answered, now, with its
|
||||
current reading. Whether the NUMBER moved is irrelevant, so a healthy meter
|
||||
under a flat load resets the age exactly like a busy one. Home Assistant
|
||||
cannot provide this at all - it emits `state_changed` only on a change, does
|
||||
not advance `last_reported` on either serialiser for a repeat, and refuses a
|
||||
`state_reported` subscription outright ("Event filter is required"). Measured
|
||||
on the ENV-01 rig over 70 s of a frozen meter, and independently against the
|
||||
live house over ten repeated readings. So on `ha_signed` the age means "time
|
||||
since the value changed", and our own capture of this house's meter has
|
||||
42.2 s and 97.0 s between changes - both past the default `meter_max_age_s`
|
||||
of 30, i.e. a false trip to 0 W on a perfectly healthy meter.
|
||||
|
||||
Everything else is TEL-01's pipeline unchanged: ingest timestamping,
|
||||
`meter_max_age_s`, the clock-recomputed age, the plausibility bounds, and a
|
||||
failed read treated as a MISSING reading rather than 0 W.
|
||||
|
||||
⚠️ A failed or timed-out poll submits nothing. It is a rejection, so the
|
||||
last good sample and its stamp stay exactly where they were and the age goes
|
||||
on climbing - which is precisely the signal a dead meter should produce.
|
||||
|
||||
⚠️ POLL CADENCE vs `meter_max_age_s`. The age can only be as fresh as the
|
||||
poll interval, so `meter_poll_s` must sit well under `meter_max_age_s` or the
|
||||
reading flaps in and out of staleness on a healthy meter. The real meter
|
||||
updates every ~5.0 s (NOTES.md:640 measures 4.97 s), so polling faster than
|
||||
that buys nothing but re-reads. Default 5 s against a 30 s max age; the
|
||||
startup check in build_source refuses `meter_poll_s >= meter_max_age_s` and
|
||||
warns past half of it.
|
||||
|
||||
ponytail: a plain `asyncio.sleep` loop rather than a scheduler, and no
|
||||
backoff. A poll that fails costs one rejection and is retried on the next
|
||||
tick; a meter that is down stays down and the age reports it. The ceiling is
|
||||
a meter so slow that polls overlap - the request timeout is held under the
|
||||
poll interval so they cannot.
|
||||
"""
|
||||
|
||||
def __init__(self, session, ingest: P1Ingest, host: str, *,
|
||||
port: int = HOMEWIZARD_PORT, poll_s: float = 5.0,
|
||||
timeout_s: float | None = None):
|
||||
self.session = session
|
||||
self.ingest = ingest
|
||||
self.host, self.port = host, int(port)
|
||||
self.poll_s = float(poll_s)
|
||||
# ⚠️ Held under the poll interval on purpose: a timeout longer than the
|
||||
# cadence queues polls behind a hung meter, and a backlog of requests
|
||||
# all landing at once would stamp several arrivals for one measurement.
|
||||
self.timeout_s = float(timeout_s) if timeout_s else max(1.0, self.poll_s * 0.8)
|
||||
self.url = f"http://{self.host}:{self.port}{HOMEWIZARD_PATH}"
|
||||
self.connected = False
|
||||
self.polls = 0
|
||||
self.poll_errors = 0
|
||||
self._fingerprint: tuple | None = None
|
||||
self._changed_mono: float | None = None
|
||||
|
||||
@property
|
||||
def unchanged_s(self) -> float | None:
|
||||
"""Seconds since the meter last served a DIFFERENT measurement.
|
||||
|
||||
⚠️ Diagnostic only, and deliberately NOT folded into
|
||||
`sensor.p1_sample_age_s`. A frozen meter (SAFETY-01's six-minute
|
||||
runaway) answers 200 OK with a stale document forever, so no arrival
|
||||
detector can see it - only the document standing still can, and this is
|
||||
that signal. It is exposed rather than acted on because it is NOT safe
|
||||
as a 30 s watchdog input: this controller regulates grid power toward
|
||||
~0 W, and at a converged -10 W the export register takes six minutes to
|
||||
advance by its 1 Wh resolution while the power figure legitimately
|
||||
repeats. Thresholding that would rebuild the very limit cycle the
|
||||
arrival stamp just removed, at the exact operating point we aim for.
|
||||
Whoever wires a freeze detector must handle the low-power case first.
|
||||
"""
|
||||
if self._changed_mono is None:
|
||||
return None
|
||||
return max(0.0, time.monotonic() - self._changed_mono)
|
||||
|
||||
async def run(self) -> None:
|
||||
"""Long-lived task: poll, submit, sleep, forever.
|
||||
|
||||
⚠️ Nothing but cancellation may end this loop. An escaping exception
|
||||
would kill the poll task for the lifetime of the add-on, and it would do
|
||||
it QUIETLY: the failure mode is safe (no submissions, the age climbs, the
|
||||
watchdog holds the battery at 0 W) but it looks identical to a dead
|
||||
meter, so the operator goes hunting the wrong device. Retry on the next
|
||||
tick instead - poll_s is already the retry cadence, so no backoff.
|
||||
"""
|
||||
_LOG.info("P1 ingest: polling %s every %.1fs", self.url, self.poll_s)
|
||||
while True:
|
||||
try:
|
||||
await self.poll_once()
|
||||
except asyncio.CancelledError:
|
||||
raise
|
||||
except Exception as err: # noqa: BLE001 - the task must outlive it
|
||||
_LOG.warning("P1 meter poll %s: %s - retrying in %.1fs", self.url,
|
||||
str(err) or type(err).__name__, self.poll_s)
|
||||
await asyncio.sleep(self.poll_s)
|
||||
|
||||
async def poll_once(self) -> bool:
|
||||
"""One GET. Returns True if a sample was accepted."""
|
||||
self.polls += 1
|
||||
try:
|
||||
async with self.session.get(
|
||||
self.url,
|
||||
timeout=aiohttp.ClientTimeout(total=self.timeout_s)) as resp:
|
||||
if resp.status != 200:
|
||||
raise P1Error(f"meter returned HTTP {resp.status}")
|
||||
# content_type=None: the meter's own firmware is the authority on
|
||||
# what it serves, and refusing a reading over a Content-Type
|
||||
# header would be a fabricated outage.
|
||||
# ⚠️ Kept because a real HomeWizard firmware that ever answers
|
||||
# text/plain would otherwise read as a dead meter and hold the
|
||||
# battery at 0 W. (This was once recorded here as an equivalent
|
||||
# mutant - it is not. aiohttp's json_response always sets
|
||||
# application/json, but web.Response(text=...) defaults to
|
||||
# text/plain, so the fake meter CAN serve valid JSON under the
|
||||
# wrong header, and test_p1.py now does.)
|
||||
doc = await resp.json(content_type=None)
|
||||
except asyncio.CancelledError:
|
||||
raise
|
||||
except Exception as err: # noqa: BLE001 - any read failure is a gap
|
||||
self.connected = False
|
||||
self.poll_errors += 1
|
||||
# ⚠️ str() of a bare asyncio.TimeoutError is the EMPTY STRING, so
|
||||
# f"...: {err}" renders "last error:" and then nothing - on the
|
||||
# status page, on a hung meter, at the moment the battery has just
|
||||
# dropped to 0 W and someone is reading that line to find out why.
|
||||
# The class name is the only thing that says "it timed out".
|
||||
# ⚠️ str(err), not `err or ...`: an exception object is ALWAYS truthy,
|
||||
# empty message or not, so the `or` would never reach the fallback.
|
||||
self.ingest.reject(
|
||||
f"meter poll {self.url}: {str(err) or type(err).__name__}")
|
||||
return False
|
||||
|
||||
self.connected = True
|
||||
try:
|
||||
sample = parse_homewizard(doc, self.ingest.phases)
|
||||
# ⚠️ Submitted unconditionally, INCLUDING a document identical to the
|
||||
# last one. The response is the arrival; the number is not.
|
||||
# Inside the try on purpose: submit() outside it would put a raise on
|
||||
# a path with no handler at all, killing the poll task permanently -
|
||||
# safely (the age climbs) but silently. run() backstops the rest.
|
||||
self.ingest.submit(sample)
|
||||
self._note(doc)
|
||||
except P1Error as err:
|
||||
self.ingest.reject(err)
|
||||
return False
|
||||
return True
|
||||
|
||||
def _note(self, doc) -> None:
|
||||
fp = measurement_fingerprint(doc)
|
||||
if self._changed_mono is None or fp != self._fingerprint:
|
||||
self._fingerprint = fp
|
||||
self._changed_mono = time.monotonic()
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# selection
|
||||
# --------------------------------------------------------------------------- #
|
||||
@@ -683,15 +1044,133 @@ def is_enabled(opts: dict) -> bool:
|
||||
return str(opts.get("meter_source", "off") or "off").strip() not in ("off", "")
|
||||
|
||||
|
||||
def homewizard_host_port(opts: dict) -> tuple[str, str]:
|
||||
"""`p1_host` split into host and (still unparsed) port text.
|
||||
|
||||
One definition because validate_meter_options() and build_source() must
|
||||
agree byte for byte about what counts as a usable address - a pasted browser
|
||||
URL is the obvious way to fill this in wrong.
|
||||
"""
|
||||
host = str(opts.get("p1_host", "") or "").strip()
|
||||
host = host.removeprefix("http://").removeprefix("https://").rstrip("/")
|
||||
host, _, port_s = host.partition(":")
|
||||
return host, port_s
|
||||
|
||||
|
||||
def validate_meter_options(opts: dict, phases: int, max_age_s: float) -> list[str]:
|
||||
"""Every way `meter_source` can name a meter that will never produce a reading.
|
||||
|
||||
⚠️ THIS IS THE ONLY PLACE THAT KNOWS THESE RULES. It used to be a run of
|
||||
inline `return None`s inside build_source(); CFG-01 lifted them out because
|
||||
the same predicates now have two callers with two different consequences:
|
||||
|
||||
validate.validate_startup_config() refuses to start the add-on
|
||||
build_source() returns None, as it always did
|
||||
|
||||
They are one function and not two on purpose. A second copy of "what makes a
|
||||
meter config wrong" would drift, and the half that drifted would be the one
|
||||
that decides whether the process is allowed to run.
|
||||
|
||||
Checked ONCE at startup rather than per telegram, because a misconfigured
|
||||
source otherwise fails in the one way indistinguishable from a healthy source
|
||||
nobody has sent anything to yet: no samples, a climbing age, the firmware
|
||||
watchdog holding the battery at 0 W, and nothing in the log saying why.
|
||||
|
||||
Returns a list of human-readable problems; empty means the config is usable.
|
||||
`phases` and `max_age_s` are passed in rather than read from opts so the
|
||||
caller decides whether it is validating the options or an already-built
|
||||
P1Ingest - build_source() has an ingest whose values may not have come from
|
||||
this dict.
|
||||
"""
|
||||
source = str(opts.get("meter_source", "off") or "off").strip()
|
||||
if source in ("off", ""):
|
||||
return []
|
||||
problems: list[str] = []
|
||||
|
||||
if source == SOURCE_HA:
|
||||
imp = str(opts.get("p1_import_entity", "") or "").strip()
|
||||
exp = str(opts.get("p1_export_entity", "") or "").strip()
|
||||
if not imp or not exp:
|
||||
problems.append(
|
||||
f"meter_source {SOURCE_HA} needs both p1_import_entity and "
|
||||
f"p1_export_entity (got {imp or '<blank>'!r} / {exp or '<blank>'!r})")
|
||||
elif source == SOURCE_HA_SIGNED:
|
||||
net = str(opts.get("p1_net_entity", "") or "").strip()
|
||||
phase_net = [str(e).strip() for e in
|
||||
(opts.get("p1_phase_net_entities") or []) if str(e).strip()]
|
||||
if not net:
|
||||
problems.append(
|
||||
f"meter_source {SOURCE_HA_SIGNED} needs p1_net_entity "
|
||||
"(sensor.p1_sample_age_s would otherwise be announced with "
|
||||
"nothing feeding it)")
|
||||
if phase_net and len(phase_net) != phases:
|
||||
problems.append(
|
||||
f"p1_phase_net_entities has {len(phase_net)} entities but "
|
||||
f"meter_phases is {phases} - every telegram would be rejected "
|
||||
"on the phase-count check")
|
||||
elif source == SOURCE_MQTT:
|
||||
if not str(opts.get("meter_mqtt_topic", "") or "").strip():
|
||||
problems.append(f"meter_source {SOURCE_MQTT} needs meter_mqtt_topic")
|
||||
elif source == SOURCE_HOMEWIZARD:
|
||||
host, port_s = homewizard_host_port(opts)
|
||||
if not host:
|
||||
problems.append(
|
||||
f"meter_source {SOURCE_HOMEWIZARD} needs p1_host (the meter's "
|
||||
"own address, e.g. 192.168.2.250)")
|
||||
if port_s:
|
||||
try:
|
||||
int(port_s)
|
||||
except ValueError:
|
||||
problems.append(f"p1_host {opts.get('p1_host')!r} has an "
|
||||
"unparseable port")
|
||||
try:
|
||||
# ⚠️ Not `or 5`: that turns an explicit 0 into the default, and a
|
||||
# cadence of 0 is a misconfiguration that must be reported, not
|
||||
# quietly corrected into something that looks like it was asked for.
|
||||
raw = opts.get("meter_poll_s", 5)
|
||||
poll_s = float(5 if raw is None or raw == "" else raw)
|
||||
except (TypeError, ValueError):
|
||||
problems.append(f"meter_poll_s {opts.get('meter_poll_s')!r} is not a number")
|
||||
else:
|
||||
if poll_s <= 0:
|
||||
problems.append("meter_poll_s must be positive")
|
||||
# ⚠️ The age can never be fresher than the poll interval. At or past
|
||||
# max_age_s every reading is stale before its successor arrives, so
|
||||
# the controller would sit permanently on missing inputs while the
|
||||
# meter is perfectly healthy - refuse it rather than ship that.
|
||||
elif poll_s >= max_age_s:
|
||||
problems.append(
|
||||
f"meter_poll_s {poll_s:.1f} is not under meter_max_age_s "
|
||||
f"{max_age_s:.1f} - every reading would go stale before the "
|
||||
"next poll")
|
||||
else:
|
||||
problems.append(
|
||||
f"meter_source {source!r} is not one of "
|
||||
+ ", ".join((SOURCE_HA, SOURCE_MQTT, SOURCE_HA_SIGNED, SOURCE_HOMEWIZARD)))
|
||||
return problems
|
||||
|
||||
|
||||
def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
|
||||
"""Return the transport named by `meter_source`, or None if disabled.
|
||||
|
||||
This is the whole of AC 1's "switchable": every consumer reads P1Ingest, so
|
||||
changing transport is a config edit, never a code path.
|
||||
|
||||
⚠️ In the add-on this is now unreachable with a bad config -
|
||||
validate_startup_config() refuses to start on anything
|
||||
validate_meter_options() rejects. The guard stays because this function is
|
||||
also called directly by tests and by anything embedding P1Ingest, and
|
||||
"returns None" is a safer default for those callers than a transport that
|
||||
can never read.
|
||||
"""
|
||||
source = str(opts.get("meter_source", "off") or "off").strip()
|
||||
if not is_enabled(opts):
|
||||
return None
|
||||
problems = validate_meter_options(opts, ingest.phases, ingest.max_age_s)
|
||||
if problems:
|
||||
for problem in problems:
|
||||
_LOG.error("%s - P1 ingestion disabled", problem)
|
||||
return None
|
||||
if source == SOURCE_HA:
|
||||
return HaDsmrSource(session, ingest, {
|
||||
"import": opts.get("p1_import_entity", ""),
|
||||
@@ -699,12 +1178,29 @@ def build_source(opts: dict, ingest: P1Ingest, session, broker: dict | None):
|
||||
"phase_import": opts.get("p1_phase_import_entities") or [],
|
||||
"phase_export": opts.get("p1_phase_export_entities") or [],
|
||||
})
|
||||
if source == SOURCE_HA_SIGNED:
|
||||
return HaSignedSource(session, ingest, {
|
||||
"net": str(opts.get("p1_net_entity", "") or "").strip(),
|
||||
"phase_net": [str(e).strip() for e in
|
||||
(opts.get("p1_phase_net_entities") or []) if str(e).strip()],
|
||||
})
|
||||
if source == SOURCE_HOMEWIZARD:
|
||||
host, port_s = homewizard_host_port(opts)
|
||||
port = int(port_s) if port_s else HOMEWIZARD_PORT
|
||||
raw = opts.get("meter_poll_s", 5)
|
||||
poll_s = float(5 if raw is None or raw == "" else raw)
|
||||
# A warning, not a refusal: one missed poll costs a stale reading and a
|
||||
# 0 W cycle, which is fail-safe. The refusal above is for cadences that
|
||||
# can NEVER be fresh.
|
||||
if poll_s > ingest.max_age_s / 2:
|
||||
_LOG.warning("meter_poll_s %.1f leaves no room under meter_max_age_s "
|
||||
"%.1f: one missed poll makes the reading stale. The meter "
|
||||
"updates every ~5 s; 5 s against 30 s is the tested pair.",
|
||||
poll_s, ingest.max_age_s)
|
||||
return HomeWizardLocalSource(session, ingest, host, port=port, poll_s=poll_s)
|
||||
if source == SOURCE_MQTT:
|
||||
broker = broker or {}
|
||||
return MqttP1Source(ingest, str(opts.get("meter_mqtt_topic", "")),
|
||||
broker.get("host"), broker.get("port", 1883),
|
||||
broker.get("username"), broker.get("password"))
|
||||
if source:
|
||||
_LOG.error("meter_source %r is not %s or %s - P1 ingestion disabled",
|
||||
source, SOURCE_HA, SOURCE_MQTT)
|
||||
return None
|
||||
|
||||
@@ -0,0 +1,315 @@
|
||||
"""Startup configuration validation - the gate before the control loop runs.
|
||||
|
||||
WHAT THIS IS FOR, in one sentence: some configurations are not "a bit off", they
|
||||
are configurations under which the add-on's own safety machinery does not work,
|
||||
and for those the correct behaviour is to refuse to start rather than to log a
|
||||
line and carry on.
|
||||
|
||||
⚠️ THE FAILURE THIS REPLACES. `main.py` used to read the setpoint device's own
|
||||
±5000 W rating, notice that a configured `max_w` of, say, 8000 W exceeded it,
|
||||
write one WARNING to a log nobody reads, and then run anyway with
|
||||
`write_setpoint()` quietly clamping. The operator's stated ceiling was simply not
|
||||
the ceiling, and the only evidence was a line that had scrolled off. specs §1.5
|
||||
is explicit that a configuration in which the system cannot honour what it was
|
||||
told is refused at startup, not survived at runtime.
|
||||
|
||||
WHERE THE LINE IS DRAWN, and why it is not further out. A validator that refuses
|
||||
on trivia gets switched off by the first person it inconveniences, so this one
|
||||
refuses only where **continuing produces one of two outcomes:**
|
||||
|
||||
(a) **a stated limit is untrue** - the operator configured a bound, a lower
|
||||
layer silently enforces a different one, and nothing says which won; or
|
||||
(b) **the add-on is inert and indistinguishable from healthy** - it starts,
|
||||
serves its UI, reports green, and moves no energy, with no symptom that
|
||||
separates it from a correctly-idle system.
|
||||
|
||||
⚠️ (b) IS NOT A SPECIAL CASE OF (a), and an earlier draft of this file wrongly
|
||||
implied it was by claiming every refusal here "makes a safety mechanism
|
||||
inoperative". It does not: when `setpoint_entity` is blank, layer 1 pinning the
|
||||
inverter at 0 W is the failsafe WORKING. The problem is not that the system
|
||||
becomes unsafe, it is that it becomes a very convincing impression of a working
|
||||
controller - and an operator has no way to tell. That is its own reason to
|
||||
refuse, and stating it as one is what stops the rule being stretched later to
|
||||
cover mere untidiness.
|
||||
|
||||
Both halves have to stay narrow. (a) is not "any two numbers that could
|
||||
disagree"; it is a bound the operator SET being overridden by a layer they
|
||||
cannot see. (b) is not "anything degraded"; it is inert AND silent - if a red
|
||||
NOT READY banner already names the problem, (b) does not apply.
|
||||
|
||||
1. `max_w` outside the setpoint device's own rating. [(a)]
|
||||
The stated limit is untrue. arbiter.py's `supervised` SAFETY claim says the
|
||||
output is bounded by ±max_w; it is not, it is bounded by the device, and the
|
||||
two numbers disagree. Which one wins is a coin toss to anyone reading the
|
||||
config.
|
||||
|
||||
2. No `setpoint_entity`. [(b)]
|
||||
A controller with no actuator, and nothing about it looks broken.
|
||||
`write_setpoint()` returns immediately on a blank entity, so: no device
|
||||
rating is ever read (the `device` SAFETY claim is never made at all), and
|
||||
the ESP32 heartbeat - the thing that feeds LAYER 1 - never happens. The
|
||||
add-on serves a UI, publishes MQTT, resolves claims, and moves nothing.
|
||||
Layer 1 then holds the inverter at 0 W, which is the failsafe working
|
||||
exactly as designed - this is (b), not (a). Nothing is unsafe; it is simply
|
||||
impossible to tell from the outside that the thing is doing nothing.
|
||||
|
||||
3. A `meter_source` that can never produce a reading. [(b)]
|
||||
§5.1 makes P1 the only authoritative measurement and deliberately provides
|
||||
no fallback, so a transport that cannot be built means `grid` is None
|
||||
forever: permanent "inputs missing", 0 W, and a status page that reports a
|
||||
meter with a climbing age exactly as it would for a healthy meter nobody has
|
||||
sent anything to yet. The predicates live in `p1.validate_meter_options()`,
|
||||
which is also what `build_source()` uses - one definition, two callers.
|
||||
|
||||
4. `meter_max_age_s` above the firmware's own ingest veto. [(a)]
|
||||
The purest example of (a) in the system, and structurally the same fault as
|
||||
1. The add-on's schema accepts `int(5,300)`. The firmware's threshold is a
|
||||
COMPILE-TIME SUBSTITUTION - `max_age_s: "30"` in
|
||||
goodwe-master-stage4-failsafe.yaml - used by both its monotonic receipt
|
||||
clock and its `ingest_stale` veto, which trips layer 1 on
|
||||
`p1_age_s >= 30`. Set 120 and the add-on believes a 119 s reading is fresh
|
||||
and keeps commanding into it, while the firmware vetoed at 30 s and is
|
||||
holding the inverter at 0 W. Status page: healthy meter, running
|
||||
controller, nothing moving, and no line anywhere saying the number you set
|
||||
was overruled. That firmware file's own comment says a lower bound on this
|
||||
"belongs in CFG-01, not here" - so here it is.
|
||||
|
||||
5. `sign_disagree_w` at or above `max_w`. [(a)]
|
||||
The arbiter's `supervised` limit bounds every command to +-max_w, and
|
||||
SAFETY-02's predicate needs `abs(command) > sign_disagree_w`. Set the
|
||||
threshold at or above the ceiling and the command side of the comparison
|
||||
is unsatisfiable BY CONSTRUCTION: the watchdog can never fire, on any
|
||||
input, ever. Same shape as 1 and 4 - the operator set a number, a layer
|
||||
they cannot see makes it mean something else, and nothing says so. Worse
|
||||
here, because what the status page reports in that state is "sign
|
||||
watchdog: armed". A disarmed guard that advertises itself as armed is the
|
||||
one thing this project has decided repeatedly it will not ship.
|
||||
|
||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
|
||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||
extra headroom buys is more wrong-direction power to unwind after
|
||||
saturation - but the arbiter's `supervised` limit still binds the wire to
|
||||
±max_w, so nothing out of range ever reaches the inverter. The cost is
|
||||
latency, not amperage. Warned about, not refused.
|
||||
- A missing `soc_entity` / `batt_entity`. `inputs_ok` goes False, the loop
|
||||
commands 0 W, and `checks()` already renders a red NOT READY banner naming
|
||||
the missing entity. Fail-safe AND already loud; a refusal adds nothing.
|
||||
- A `setpoint_entity` that exists in the config but is not found on the Core
|
||||
API at startup. This is the transient case - ESPHome is frequently not up
|
||||
yet when the add-on boots - and refusing here would turn a device that
|
||||
arrives thirty seconds late into a restart loop needing a human. It stays a
|
||||
NOT READY banner.
|
||||
- `meter_poll_s` above half `meter_max_age_s`. One missed poll costs a stale
|
||||
reading and a 0 W cycle. Warned about in p1.py, not refused.
|
||||
"""
|
||||
|
||||
import logging
|
||||
|
||||
from .p1 import is_enabled, validate_meter_options
|
||||
|
||||
_LOG = logging.getLogger("goodwe.config")
|
||||
|
||||
# ⚠️ A MIRROR OF A FIRMWARE CONSTANT, AND IT CANNOT BE IMPORTED. The firmware
|
||||
# threshold is a compile-time YAML substitution baked into the ESP32 image
|
||||
# (`max_age_s: "30"`, master/goodwe-master-stage4-failsafe.yaml), so nothing at
|
||||
# runtime can ask the board what value it was built with. This number is a copy,
|
||||
# and a copy of a constant in another repo is a thing that goes stale.
|
||||
#
|
||||
# What makes that acceptable here: the copy can only ever be WRONG IN THE SAFE
|
||||
# DIRECTION for the check below. If the firmware's veto is raised above 30, this
|
||||
# refuses some configs that would in fact have worked - annoying, visible
|
||||
# immediately, and fixed by editing one line. It cannot start accepting a config
|
||||
# the firmware vetoes unless the firmware's number goes DOWN, which would be a
|
||||
# tightening nobody does silently.
|
||||
#
|
||||
# ⚠️ TEL-06 IS EDITING `ingest_stale` DIRECTLY. If that ticket changes what the
|
||||
# veto MEANS - e.g. thresholding arrival rather than the sensor's value - this
|
||||
# constant's justification has to be re-read, not just its number. Do not assume
|
||||
# a matching integer means a matching rule.
|
||||
FIRMWARE_INGEST_VETO_S = 30.0
|
||||
|
||||
# ⚠️ The complete set of option keys through which this add-on can reach an
|
||||
# actuator. specs §1.5 makes "any configuration in which two writers can reach
|
||||
# one actuator" a non-goal, and the way that non-goal is ENFORCED here is by
|
||||
# construction: there is exactly one such key, so a second writer is not
|
||||
# expressible in the options schema at all. sim/inject.py's `two_writers`
|
||||
# scenario asserts on this tuple - if a second write path is ever added, that
|
||||
# scenario goes red and somebody has to decide how the two are arbitrated
|
||||
# BEFORE the config that allows both can ship.
|
||||
ACTUATOR_WRITE_KEYS = ("setpoint_entity",)
|
||||
|
||||
|
||||
class ConfigRefused(Exception):
|
||||
"""The configuration is wrong. Not "something broke" - see main.py's handler.
|
||||
|
||||
Carries the list of problems so the caller can render them; str() is the
|
||||
first one, so an unhandled traceback still names something useful.
|
||||
"""
|
||||
|
||||
def __init__(self, problems: list[str]):
|
||||
self.problems = problems
|
||||
super().__init__(problems[0] if problems else "configuration refused")
|
||||
|
||||
|
||||
def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]:
|
||||
"""Return the list of reasons this configuration must not be started.
|
||||
|
||||
Empty list means go. `dev_min`/`dev_max` are the setpoint device's own
|
||||
reported range (`hass.limits()`), or None when the device could not be
|
||||
reached - in which case the range checks are skipped rather than guessed at,
|
||||
for the transient reason in this module's docstring.
|
||||
|
||||
Pure and side-effect free apart from two warnings, so it can be called from
|
||||
a test or from sim/inject.py without a Home Assistant anywhere near it.
|
||||
"""
|
||||
problems: list[str] = []
|
||||
|
||||
# --- 1. an actuator to write to ------------------------------------------
|
||||
writers = [k for k in ACTUATOR_WRITE_KEYS
|
||||
if str(opts.get(k, "") or "").strip()]
|
||||
if not writers:
|
||||
problems.append(
|
||||
"setpoint_entity is not set, so this add-on has no actuator: every "
|
||||
"write is a no-op, the device's own rating is never read, and the "
|
||||
"ESP32 heartbeat that holds off the layer-1 failsafe never happens. "
|
||||
"It would run, look healthy, and move no energy at all. Set it to "
|
||||
"the ESPHome number entity that carries the setpoint.")
|
||||
|
||||
# --- 2. the configured ceiling against the device's own rating -----------
|
||||
max_w = _number(opts, "max_w", 2000.0)
|
||||
if max_w is None:
|
||||
problems.append(f"max_w {opts.get('max_w')!r} is not a number")
|
||||
# ⚠️ config.yaml's int(100,5000) already blocks this on a real install, so
|
||||
# the check is not for the Supervisor path - it is because
|
||||
# validate_startup_config() is now also sim/inject.py's entry point and can
|
||||
# be handed any dict at all. A max_w of 0 or below inverts the arbiter's
|
||||
# `supervised` bounds (lo=-max_w becomes the HIGHER number), and a limit
|
||||
# claim whose lo exceeds its hi is exactly the contradiction the arbiter
|
||||
# resolves to 0 W - i.e. it would look like a safety trip rather than the
|
||||
# nonsense config it is.
|
||||
elif max_w <= 0:
|
||||
problems.append(
|
||||
f"max_w is {max_w:.0f} W and must be positive - it is a magnitude, "
|
||||
"not a signed setpoint. At or below zero the arbiter's supervised "
|
||||
f"limit becomes lo={-max_w:.0f} / hi={max_w:.0f}, which is a "
|
||||
"contradiction it resolves to 0 W, so the controller would look "
|
||||
"like it was tripping rather than misconfigured.")
|
||||
elif dev_max is not None and max_w > dev_max:
|
||||
problems.append(
|
||||
f"max_w is {max_w:.0f} W but {opts.get('setpoint_entity') or 'the setpoint device'} accepts at "
|
||||
f"most {dev_max:.0f} W - THE DEVICE WINS, so the {max_w:.0f} W you "
|
||||
f"configured would silently never happen. Lower max_w to "
|
||||
f"{dev_max:.0f} W or less, or point setpoint_entity at a device that "
|
||||
f"can take {max_w:.0f} W.")
|
||||
elif dev_min is not None and -max_w < dev_min:
|
||||
problems.append(
|
||||
f"max_w is {max_w:.0f} W, so this controller may command "
|
||||
f"{-max_w:.0f} W, but {opts.get('setpoint_entity') or 'the setpoint device'} accepts no less "
|
||||
f"than {dev_min:.0f} W - THE DEVICE WINS on the charge side. Lower "
|
||||
f"max_w to {abs(dev_min):.0f} W or less.")
|
||||
|
||||
# --- 3. a meter that can actually read -----------------------------------
|
||||
# ⚠️ Not a second copy of these rules - p1.py owns them, because
|
||||
# build_source() has to apply the identical predicates and a drifted copy
|
||||
# would be worse than no check.
|
||||
phases = _number(opts, "meter_phases", 1.0)
|
||||
max_age_s = _number(opts, "meter_max_age_s", 30.0)
|
||||
if phases is None or max_age_s is None:
|
||||
problems.append("meter_phases and meter_max_age_s must both be numbers "
|
||||
f"(got {opts.get('meter_phases')!r} / "
|
||||
f"{opts.get('meter_max_age_s')!r})")
|
||||
else:
|
||||
problems.extend(validate_meter_options(opts, int(phases), max_age_s))
|
||||
|
||||
# --- 4. the staleness window the FIRMWARE will actually enforce -----------
|
||||
# ⚠️ Only when P1 ingestion is on, and that is a real scope limit rather than
|
||||
# caution: meter_max_age_s is read by nothing but P1Ingest, and the veto it
|
||||
# collides with keys off `p1_age_s.has_state()`, which is only ever published
|
||||
# when ingestion is running (see Controller.publish()). With meter_source off
|
||||
# there is no sensor, the veto is inert, and the number governs nothing.
|
||||
#
|
||||
# Strictly greater, not >=: the firmware trips at `>= 30` and P1Ingest goes
|
||||
# stale at `> max_age_s`, so 30 against 30 has the firmware fractionally
|
||||
# stricter by one sample. That is the shipped default and the tested pair.
|
||||
# BELOW 30 is fine and deliberately not refused - the add-on then gives up
|
||||
# first, which is fail-safe and visible on its own status page. Only ABOVE is
|
||||
# the silent case, where the add-on keeps commanding into a reading the board
|
||||
# has already rejected.
|
||||
if (is_enabled(opts) and max_age_s is not None
|
||||
and max_age_s > FIRMWARE_INGEST_VETO_S):
|
||||
problems.append(
|
||||
f"meter_max_age_s is {max_age_s:.0f} s but the ESP32 firmware vetoes "
|
||||
f"any P1 sample at {FIRMWARE_INGEST_VETO_S:.0f} s and forces the "
|
||||
"layer-1 failsafe - THE FIRMWARE WINS, and it wins silently. This "
|
||||
f"add-on would treat a {max_age_s - 1:.0f} s reading as fresh and "
|
||||
"keep commanding, while the inverter sat at 0 W with a healthy-"
|
||||
"looking meter on the status page. Lower meter_max_age_s to "
|
||||
f"{FIRMWARE_INGEST_VETO_S:.0f} s or less (30 s is the tested value), "
|
||||
"or rebuild the firmware with a matching max_age_s and update "
|
||||
"validate.FIRMWARE_INGEST_VETO_S.")
|
||||
|
||||
# --- 5. a sign watchdog that can actually fire ---------------------------
|
||||
# ⚠️ Strictly `>=`, matching the predicate exactly: watchdog.py tests
|
||||
# `abs(commanded_w) > min_w`, and the arbiter holds `abs(commanded_w)` at or
|
||||
# below max_w, so threshold == max_w is already unsatisfiable. Anything
|
||||
# BELOW max_w is reachable and therefore fine - this refuses the disarmed
|
||||
# case only, not "close to the rail".
|
||||
sign_w = _number(opts, "sign_disagree_w", 300.0)
|
||||
if sign_w is None:
|
||||
problems.append(f"sign_disagree_w {opts.get('sign_disagree_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and sign_w >= max_w:
|
||||
problems.append(
|
||||
f"sign_disagree_w is {sign_w:.0f} W but max_w is {max_w:.0f} W, so "
|
||||
"the SAFETY-02 sign-disagreement watchdog can never fire: the "
|
||||
"arbiter never lets a command exceed max_w, and the watchdog needs "
|
||||
f"a command over {sign_w:.0f} W. It would sit there reporting "
|
||||
"'armed' on the status page while being incapable of tripping - the "
|
||||
f"one runaway failure mode this system has actually observed. Lower "
|
||||
f"sign_disagree_w below {max_w:.0f} W (300 W is the measured "
|
||||
"default), or raise max_w.")
|
||||
|
||||
# --- warnings: real, but not worth refusing over -------------------------
|
||||
integ = opts.get("integrator_max_w")
|
||||
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
|
||||
if integ_w is not None and max_w is not None and integ_w > max_w:
|
||||
_LOG.warning(
|
||||
"integrator_max_w %.0f W is above max_w %.0f W. Not refused - the "
|
||||
"arbiter still bounds the wire to +-max_w - but the only thing the "
|
||||
"extra headroom buys is more wrong-direction power to unwind after "
|
||||
"saturation. 0 (follow max_w) is the recommended value.",
|
||||
integ_w, max_w)
|
||||
|
||||
return problems
|
||||
|
||||
|
||||
def _number(opts: dict, key, default):
|
||||
raw = opts.get(key, default)
|
||||
if raw is None or raw == "":
|
||||
return default
|
||||
try:
|
||||
return float(raw)
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
|
||||
|
||||
def refuse(problems: list[str]) -> None:
|
||||
"""Log a refusal an operator can tell apart from a crash. Does not raise.
|
||||
|
||||
⚠️ THE POINT OF THE BANNER. "You configured this wrong" must not read like
|
||||
"it broke". A Python traceback in an add-on log means the same thing to most
|
||||
operators as a segfault - file a bug - whereas this block names the keys,
|
||||
names the fix, and says in words that nothing is broken. main.py catches
|
||||
ConfigRefused and exits 78 (sysexits EX_CONFIG), so no traceback is printed
|
||||
at all and even the exit status distinguishes the two.
|
||||
"""
|
||||
_LOG.error("=" * 72)
|
||||
_LOG.error("REFUSING TO START: the add-on configuration is not usable.")
|
||||
_LOG.error("This is a CONFIGURATION problem, not a crash. Nothing is broken;")
|
||||
_LOG.error("the add-on will start as soon as the settings below are fixed.")
|
||||
_LOG.error("Fix them in Settings > Add-ons > GoodWe RS485 Controller >")
|
||||
_LOG.error("Configuration, then start the add-on again.")
|
||||
_LOG.error("-" * 72)
|
||||
for i, problem in enumerate(problems, 1):
|
||||
_LOG.error(" %d. %s", i, problem)
|
||||
_LOG.error("=" * 72)
|
||||
@@ -0,0 +1,220 @@
|
||||
"""SAFETY-02 - the sign-disagreement watchdog.
|
||||
|
||||
WHAT IT CATCHES, in one sentence: a grid-following loop that is pushing power in
|
||||
the wrong direction, which every other guard in this system is blind to.
|
||||
|
||||
The stale-input watchdog (SAFETY-01) asks "is the meter still talking?". The
|
||||
saturation freeze asks "can the inverter follow?". The output clamp asks "is the
|
||||
number too big?". A loop can pass all three and still be charging the battery
|
||||
out of the grid while the house imports - the meter is fresh, the inverter is
|
||||
tracking beautifully, and the magnitude is inside the rating. The only thing
|
||||
that separates that from healthy operation is the SIGN.
|
||||
|
||||
⚠️ THIS IS NOT A HYPOTHETICAL. On 2026-08-20 the vendor controller (Illusmart)
|
||||
did exactly this four times in one day (NOTES.md §4.7). Both captures of that
|
||||
bus are committed - `sim/scenarios/bus-2026-08-20.log.gz` and the healthy
|
||||
`bus-2026-08-23.log.gz` in the infra repo - and `sim/replay_sign.py` drives this
|
||||
module over both of them. Every number in this file was measured on those two
|
||||
days, not chosen:
|
||||
|
||||
day samples gated in sign agreement
|
||||
2026-08-23 4 127 / 16 349 92.9 % (healthy)
|
||||
2026-08-20 6 892 / 15 598 55.6 % (the whole fault day)
|
||||
episode A 15:26-16:43 0.3 %
|
||||
episode B 17:11-18:28 0.8 %
|
||||
episode C 20:01-20:31 11.0 %
|
||||
episode D 20:55-21:11 0.0 %
|
||||
|
||||
That is the signature, and it is the SAME signature in all four episodes: not a
|
||||
noisier version of healthy, a near-total inversion.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY IT LIVES HERE AND NOT IN THE FIRMWARE OR THE WITNESS
|
||||
|
||||
Three vantage points see three different things. The firmware knows what it
|
||||
WROTE, the witness Pi knows what was ON THE WIRE and whether the inverter ACKed
|
||||
it, and the add-on knows what it INTENDED and holds the authoritative meter.
|
||||
|
||||
This check is not command-versus-wire; it is command-versus-physics. It needs
|
||||
the emitted setpoint and the P1 net figure in the same place, and it needs the
|
||||
authority to command zero when they fight:
|
||||
|
||||
- the witness is read-only by charter and cannot command anything, so it could
|
||||
raise the alarm but never take the trip action the AC requires;
|
||||
- the firmware has the wire but not the meter. §5.1 makes P1 the only
|
||||
authoritative grid figure and the board only ever receives its AGE
|
||||
(`sensor.goodwe_p1_sample_age`), never its value. Putting the check there
|
||||
would mean shipping the meter to the ESP32 for no other reason, and it would
|
||||
be C++ per install rather than one generic guard;
|
||||
- the add-on has both halves already, plus an arbiter that can outrank every
|
||||
strategy with a P_SAFETY claim.
|
||||
|
||||
The cost of standing here is real and worth stating: this watchdog compares what
|
||||
we MEANT to put on the wire against the meter. If the firmware or the driver
|
||||
inverts the sign on the way out, the add-on's own view still agrees with itself
|
||||
and this check stays silent. That gap is a wire-versus-intent problem and it
|
||||
belongs to the witness, not here.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT "DISAGREEMENT" MEANS, PRECISELY
|
||||
|
||||
disagree = following
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > min_w
|
||||
and abs(grid_w) > min_w
|
||||
|
||||
Four gates, and each one exists to exclude a specific thing that is NOT a fault:
|
||||
|
||||
1. `following`. ⚠️ THE GATE THAT IS EASIEST TO FORGET AND MOST EXPENSIVE TO
|
||||
OMIT. Sign agreement is a property of a GRID-FOLLOWING loop. It is not
|
||||
expected of a strategy that deliberately commands against the meter -
|
||||
maintenance is exactly that. A maintenance grid charge of 2500 W into a house
|
||||
drawing 500 W puts +3000 W on the meter against a -2500 W command: opposed,
|
||||
both far over any sane threshold, and sustained for HOURS. Armed
|
||||
unconditionally this watchdog would trip on every single maintenance cycle,
|
||||
which is not a tuning problem, it is the wrong question being asked. So the
|
||||
caller says whether the grid-following loop actually won the arbitration this
|
||||
cycle, and the timer only accumulates when it did.
|
||||
|
||||
2. The strict `< 0` product. "Opposed" and "neither side is zero" in one
|
||||
expression.
|
||||
|
||||
3. The 300 W magnitude gate ON BOTH SIDES. Near zero the sign is noise, and near
|
||||
zero is where a healthy loop LIVES - the deadband holds the command still
|
||||
while the meter wanders either side of `target_grid_w`. On the healthy day
|
||||
only 4 127 of 16 349 samples (25 %) are even gated in; the other 75 % are the
|
||||
converged band where sign carries no information. This is also why the
|
||||
deadband cannot produce a false trip: inside it the meter is by definition
|
||||
under 300 W.
|
||||
|
||||
4. The 180 s continuity requirement. This is what excludes the legitimate
|
||||
transient. A load step reverses the meter's sign instantly while the command
|
||||
is still where the last cycle left it; slew limiting then needs a few cycles
|
||||
to cross over. Measured on the healthy day, the LONGEST such crossing is 30 s
|
||||
- and that is with a vendor controller far cruder than ours. 180 s is six
|
||||
times that. It is not a fitted threshold: at 60 s the healthy day still
|
||||
produces zero trips, and at 300 s the fault day still produces 13.
|
||||
|
||||
⚠️ A BATTERY THAT REFUSES A COMMAND CANNOT TRIP THIS, and that is structural
|
||||
rather than lucky. At SoC 10 % in Standby, a 1350 W discharge command into a
|
||||
1350 W import is DECLINED: the battery does nothing, so the meter stays at
|
||||
+1350 W and the command stays at +1350 W. Same sign. Agreement. A refusal leaves
|
||||
the meter where it was; only the inverter ACTING moves it, and acting in the
|
||||
commanded direction moves it toward zero, not through it. The failure mode this
|
||||
check keys on is the opposite of a refusal - it is the inverter obediently doing
|
||||
a wrong thing.
|
||||
|
||||
⚠️ A FROZEN METER cannot trip it either, for the same reason read the other way:
|
||||
a stuck reading of +800 W makes the loop command discharge and keep commanding
|
||||
discharge. Command and meter converge on AGREEING. Freezes are SAFETY-12's and
|
||||
SAFETY-01's problem, and this watchdog neither helps nor hinders there.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
STATE, TRIP AND LATCH
|
||||
|
||||
One timestamp, not a sample counter. The cycle rate is not fixed - a meter
|
||||
arrival, or `cycle_floor_s` elapsing, whichever comes first - so N samples is a
|
||||
different wall-clock window on every path, and the AC is written in minutes.
|
||||
|
||||
The latch is not optional and not a nicety. Commanding 0 W removes the command
|
||||
side of the comparison (|0| is not > 300), so the disagreement disappears the
|
||||
instant the trip works. Un-latched, this watchdog would trip, clear itself, and
|
||||
hand the actuator straight back to the loop that was driving the wrong way -
|
||||
three minutes later, forever. `tripped` therefore stays true until an operator
|
||||
`reset()`s it by starting control again, which is a deliberate human act after
|
||||
looking at why.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class SignWatchdogConfig:
|
||||
"""Defaults, not constants - config.yaml carries both (SAFETY-02 AC 5)."""
|
||||
|
||||
min_w: float = 300.0
|
||||
hold_s: float = 180.0
|
||||
|
||||
|
||||
class SignWatchdog:
|
||||
"""One instance per actuator, evaluated once per control cycle.
|
||||
|
||||
⚠️ NOT SHARED ACROSS CADENCES. `disagree_since` is a wall-clock start time,
|
||||
so driving one instance from two loops at two rates would have each one
|
||||
resetting the other's window. If a fast on-device path ever wants this
|
||||
check, it gets its own instance - the same exactly-one-writer discipline the
|
||||
arbiter applies to the actuator, applied to the detector's own state.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None):
|
||||
self.cfg = cfg or SignWatchdogConfig()
|
||||
self.disagree_since: datetime | None = None
|
||||
self.tripped = False
|
||||
self.reason = ""
|
||||
|
||||
# -- the whole check, and it is a pure function of its arguments ----------
|
||||
def evaluate(self, commanded_w, grid_w, following: bool,
|
||||
now: datetime) -> bool:
|
||||
"""Advance the detector one cycle. Returns True while tripped.
|
||||
|
||||
`commanded_w` the EMITTED setpoint - what is standing on the wire now,
|
||||
after deadband, slew, quantisation and the arbiter. Not
|
||||
the optimizer's raw wish: the wire carries the emitted
|
||||
value, so anything else can disagree with the meter for a
|
||||
reason that is not a fault.
|
||||
`grid_w` net P1, + = importing. None when the meter is stale or
|
||||
missing, which CLEARS the timer rather than accumulating
|
||||
- a frozen figure held against a moving command would
|
||||
otherwise manufacture a disagreement in about three
|
||||
minutes, on top of SAFETY-01 having already commanded
|
||||
zero for the same cause.
|
||||
`following` did the grid-following loop actually win this cycle? See
|
||||
gate 1 in the module docstring.
|
||||
`now` the caller's clock, so this stays testable and replayable.
|
||||
"""
|
||||
if self.tripped:
|
||||
# Latched. Do not re-evaluate: the trip removed the evidence.
|
||||
return True
|
||||
|
||||
cfg = self.cfg
|
||||
disagree = (
|
||||
following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w
|
||||
)
|
||||
|
||||
if not disagree:
|
||||
self.disagree_since = None
|
||||
return False
|
||||
|
||||
if self.disagree_since is None:
|
||||
self.disagree_since = now
|
||||
return False
|
||||
|
||||
held = (now - self.disagree_since).total_seconds()
|
||||
if held < cfg.hold_s:
|
||||
return False
|
||||
|
||||
self.tripped = True
|
||||
self.reason = (
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against a meter "
|
||||
f"reading {grid_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"(limits: both over {cfg.min_w:.0f} W, held over {cfg.hold_s:.0f} s)"
|
||||
)
|
||||
return True
|
||||
|
||||
@property
|
||||
def held_s(self) -> float:
|
||||
"""How long the current disagreement has been standing, for the UI."""
|
||||
if self.disagree_since is None:
|
||||
return 0.0
|
||||
return (datetime.now(self.disagree_since.tzinfo)
|
||||
- self.disagree_since).total_seconds()
|
||||
|
||||
def reset(self) -> None:
|
||||
self.disagree_since = None
|
||||
self.tripped = False
|
||||
self.reason = ""
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.2.1"
|
||||
version: "0.5.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -42,11 +42,24 @@ options:
|
||||
# --- P1 meter ingestion (specs §5.2 / §14 `meter:`) -------------------------
|
||||
# `off` keeps the original single meter_entity path above, so an existing
|
||||
# install is untouched until it opts in. ha_dsmr subscribes to the DSMR
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below.
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below;
|
||||
# ha_signed reads ONE signed HA entity (+ import / - export), which is what a
|
||||
# HomeWizard P1 publishes and what ha_dsmr cannot consume.
|
||||
# homewizard_local skips Home Assistant entirely and polls the meter's own
|
||||
# local API. ⚠️ It is the ONLY mode whose sensor.p1_sample_age_s measures when
|
||||
# the meter REPORTED rather than when the value last CHANGED - HA emits
|
||||
# nothing at all for a repeated reading - so it is the only mode a firmware
|
||||
# watchdog may threshold. See DOCS.md.
|
||||
meter_source: "off"
|
||||
meter_phases: 1
|
||||
meter_max_age_s: 30
|
||||
meter_mqtt_topic: ""
|
||||
# homewizard_local only. The meter's own address, `host` or `host:port`.
|
||||
p1_host: ""
|
||||
# homewizard_local only. Seconds between polls. Must be well under
|
||||
# meter_max_age_s - the age is never fresher than this interval - and there is
|
||||
# nothing to gain below the meter's own ~5.0 s update rate (NOTES.md:640).
|
||||
meter_poll_s: 5
|
||||
# The two UNSIGNED Belgian registers. The EMS derives net power from them
|
||||
# (import - export); do NOT point these at a signed template sensor.
|
||||
p1_import_entity: ""
|
||||
@@ -55,6 +68,15 @@ options:
|
||||
# three-phase connection; the list length must equal meter_phases.
|
||||
p1_phase_import_entities: []
|
||||
p1_phase_export_entities: []
|
||||
# ha_signed only. ONE signed net-power sensor: positive = import from the
|
||||
# grid, negative = export to it. Do NOT split it into two template sensors -
|
||||
# the split is done in the add-on (p1.split_signed) precisely so the sign
|
||||
# convention is tested rather than living in unreviewed YAML.
|
||||
p1_net_entity: ""
|
||||
# Optional, in L1..L3 order, each one signed the same way. Same role as
|
||||
# p1_phase_import_entities: the capacity-tariff peak on a three-phase
|
||||
# connection. The list length must equal meter_phases.
|
||||
p1_phase_net_entities: []
|
||||
|
||||
# --- control ---------------------------------------------------------------
|
||||
max_w: 2000
|
||||
@@ -68,8 +90,30 @@ options:
|
||||
integrator_max_w: 0
|
||||
heartbeat_s: 10
|
||||
stale_input_s: 15
|
||||
cycle_floor_s: 15
|
||||
auto_start: false
|
||||
|
||||
# --- SAFETY-02 sign-disagreement watchdog ----------------------------------
|
||||
# Trips when the emitted setpoint and the P1 net figure point OPPOSITE ways,
|
||||
# both over sign_disagree_w, continuously for sign_disagree_s. Action: 0 W and
|
||||
# a failsafe that latches until an operator starts control again.
|
||||
#
|
||||
# Both defaults are measured, not chosen. On the captured healthy day
|
||||
# (2026-08-23) the longest legitimate opposed run - a load step the loop has
|
||||
# not caught up with - is 30 s, and sign agreement over the gated samples is
|
||||
# 92.9 %. On the captured fault day (2026-08-20) the four episodes run 0.0-11 %
|
||||
# agreement with opposed runs up to 1752 s. 300 W / 180 s sits in the middle of
|
||||
# a very wide gap: at 60 s the healthy day still trips nothing, at 300 s the
|
||||
# fault day still trips 13 times. There is no reason to move either number
|
||||
# without a capture that says so. They are options because the AC says
|
||||
# thresholds are defaults rather than constants - not because they are knobs
|
||||
# anyone is expected to turn.
|
||||
#
|
||||
# ⚠️ sign_disagree_w must stay BELOW max_w or the watchdog can never fire (the
|
||||
# arbiter bounds the command to +-max_w). validate.py refuses that config.
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- maintenance -----------------------------------------------------------
|
||||
maintenance_enabled: false
|
||||
maintenance_interval_days: 28
|
||||
@@ -98,20 +142,25 @@ schema:
|
||||
batt_invert: bool
|
||||
setpoint_entity: str
|
||||
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1)
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1|ha_signed|homewizard_local)
|
||||
# ⚠️ 2 is accepted by this range but is not a real Belgian connection. A
|
||||
# telegram whose phase count disagrees is rejected at ingest and logged, so a
|
||||
# mis-set 2 shows up immediately as "0 telegrams accepted" rather than as a
|
||||
# quietly wrong number.
|
||||
meter_phases: int(1,3)
|
||||
meter_max_age_s: int(5,300)
|
||||
meter_poll_s: int(1,60)
|
||||
meter_mqtt_topic: str?
|
||||
p1_host: str?
|
||||
p1_import_entity: str?
|
||||
p1_export_entity: str?
|
||||
p1_phase_import_entities:
|
||||
- str
|
||||
p1_phase_export_entities:
|
||||
- str
|
||||
p1_net_entity: str?
|
||||
p1_phase_net_entities:
|
||||
- str
|
||||
|
||||
max_w: int(100,5000)
|
||||
gain: float(0.05,1.0)
|
||||
@@ -124,8 +173,14 @@ schema:
|
||||
integrator_max_w: int(0,15000)
|
||||
heartbeat_s: int(2,25)
|
||||
stale_input_s: int(5,120)
|
||||
cycle_floor_s: int(5,60)
|
||||
auto_start: bool
|
||||
|
||||
# No "off" value, deliberately: this is a P0 safety check and the schema is
|
||||
# not the place to make disarming it a supported configuration.
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
maintenance_enabled: bool
|
||||
maintenance_interval_days: int(1,90)
|
||||
maintenance_start_hour: int(0,23)
|
||||
|
||||
@@ -0,0 +1,213 @@
|
||||
"""Runnable check for the control loop's cadence. `python3 test_loop.py`
|
||||
|
||||
SAFETY-12: the loop must evaluate on a clock as well as on a change. Before the
|
||||
fix, `run_control()` ran `cycle()` only when the meter value differed from the
|
||||
previous poll, so a meter that repeats a value ran NO control cycles while the
|
||||
heartbeat kept re-emitting the last command - measured on the rig during TEL-05
|
||||
as 70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
|
||||
|
||||
⚠️ THIS TEST TAKES ~95 SECONDS OF WALL CLOCK (measured 93 s), on purpose, and
|
||||
that figure is the only thing standing between it and a future developer who
|
||||
decides a slow test is a broken one. The thing under test is a wall-clock floor
|
||||
inside a loop that sleeps 1 s; mocking the clock would leave the assertion
|
||||
testing the mock. It drives the real `run_control()` and counts what actually
|
||||
happened. Eight runs of the real loop is what the eight scenarios cost.
|
||||
|
||||
⚠️ If you shorten the windows, re-measure and update this number and the one in
|
||||
HANDOVER.md. An understated runtime reads as a hang.
|
||||
|
||||
`cycle_floor_s` is read from options with no lower bound in code, so a huge
|
||||
value reproduces the pre-fix behaviour exactly. Every claim below is therefore
|
||||
an A/B on one binary, not a comparison against a remembered old one.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import sys
|
||||
import time
|
||||
|
||||
from app.main import Controller
|
||||
|
||||
fails = []
|
||||
NEVER = 1e9 # cycle_floor_s so large the floor can never elapse: pre-fix
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
class FakeHass:
|
||||
"""A scripted meter and a plant that tracks the command instantly."""
|
||||
|
||||
def __init__(self, meter, soc_dies_at=None):
|
||||
self.meter = meter
|
||||
self.soc_dies_at = soc_dies_at
|
||||
self.batt = 0.0
|
||||
self.writes = []
|
||||
self.t0 = time.monotonic()
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
now = time.monotonic() - self.t0
|
||||
if entity == "sensor.grid":
|
||||
return self.meter(now)
|
||||
if entity == "sensor.batt":
|
||||
return self.batt
|
||||
if entity == "sensor.soc":
|
||||
if self.soc_dies_at is not None and now >= self.soc_dies_at:
|
||||
return None
|
||||
return 50.0
|
||||
return None
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
self.batt = float(value)
|
||||
return True
|
||||
|
||||
|
||||
class _Store:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
BASE = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": 0.6, "slew_w": 1000,
|
||||
"deadband_w": 15, "target_grid_w": -10, "step_w": 10,
|
||||
"heartbeat_s": 10, "stale_input_s": 15}
|
||||
|
||||
|
||||
def drive(meter, floor, seconds, soc_dies_at=None, **over):
|
||||
"""Run the real control loop for `seconds`; return (cycle times, writes)."""
|
||||
async def go():
|
||||
hass = FakeHass(meter, soc_dies_at)
|
||||
c = Controller(dict(BASE, cycle_floor_s=floor, **over), hass, _Store(),
|
||||
_Pub(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
stamps = []
|
||||
real = c.cycle
|
||||
|
||||
async def counted():
|
||||
stamps.append(time.monotonic() - hass.t0)
|
||||
await real()
|
||||
|
||||
c.cycle = counted
|
||||
task = asyncio.create_task(c.run_control())
|
||||
await asyncio.sleep(seconds)
|
||||
c.stopping = True
|
||||
await asyncio.wait_for(task, timeout=10)
|
||||
return stamps, hass.writes, c.target, c.reason
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
def worst_gap(stamps, seconds):
|
||||
"""Longest stretch with no cycle, including the tail after the last one."""
|
||||
edges = [0.0] + list(stamps) + [seconds]
|
||||
return max(b - a for a, b in zip(edges, edges[1:]))
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter that repeats the same value")
|
||||
FLAT = lambda t: 350.0 # noqa: E731
|
||||
FLOOR, SECONDS = 3.0, 12.0
|
||||
|
||||
pre_stamps, pre_writes, _, _ = drive(FLAT, NEVER, SECONDS)
|
||||
# The defect itself, demonstrated rather than described: one cycle at startup
|
||||
# and then nothing for the rest of the window, while writes keep happening.
|
||||
check("pre-fix: a constant meter runs exactly one cycle, at startup",
|
||||
len(pre_stamps) == 1)
|
||||
check("...while the heartbeat keeps writing anyway, so nothing looks wrong",
|
||||
len(pre_writes) >= 2)
|
||||
|
||||
post_stamps, post_writes, _, _ = drive(FLAT, FLOOR, SECONDS)
|
||||
check("post-fix: the same constant meter runs cycles throughout",
|
||||
len(post_stamps) >= int(SECONDS / FLOOR) - 1)
|
||||
# The actual acceptance criterion: a BOUND on the gap, not a count.
|
||||
gap = worst_gap(post_stamps, SECONDS)
|
||||
check(f"...with no gap longer than the floor ({gap:.1f}s <= {FLOOR + 1.5:.1f}s)",
|
||||
gap <= FLOOR + 1.5)
|
||||
check("...and the loop actually corrected, instead of holding a stale command",
|
||||
len(post_writes) > len(pre_writes))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter that changes normally - nothing may move")
|
||||
# ⚠️ THE REGRESSION GUARD, and the more important half. The floor is a deadline
|
||||
# on the gap between cycles, reset by every cycle whichever trigger fired - not
|
||||
# a second scheduler. On a healthy meter it must never elapse, so the cycle
|
||||
# count, the write count and the commanded values must be IDENTICAL either side
|
||||
# of the fix. Anything else is a new write cadence, which SAFETY-12 forbids:
|
||||
# the deadband, step_w and the 10 s force-write decide what reaches the wire,
|
||||
# and this change is only allowed to alter when the loop thinks.
|
||||
STEPS = [0.0, 300.0, 850.0, -400.0, 120.0, -900.0, 60.0]
|
||||
LIVE = lambda t: STEPS[int(t // 2) % len(STEPS)] # noqa: E731
|
||||
|
||||
a_stamps, a_writes, _, _ = drive(LIVE, NEVER, 12.0)
|
||||
b_stamps, b_writes, _, _ = drive(LIVE, FLOOR, 12.0)
|
||||
check("a changing meter runs the same number of cycles as before the fix",
|
||||
len(a_stamps) == len(b_stamps))
|
||||
check("...commanding exactly the same sequence of values", a_writes == b_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter parked at the target - the converged operating point")
|
||||
# The case TEL-05 warned about: at the converged target the power figure
|
||||
# legitimately repeats for minutes. The loop must still run, and must still
|
||||
# write nothing but the heartbeat, because the deadband - not the arrival
|
||||
# trigger - is what holds the command still.
|
||||
AT_TARGET = lambda t: -10.0 # noqa: E731
|
||||
c_stamps, c_writes, _, _ = drive(AT_TARGET, NEVER, 12.0)
|
||||
d_stamps, d_writes, _, _ = drive(AT_TARGET, FLOOR, 12.0)
|
||||
check("the loop evaluates at the converged point too", len(d_stamps) > len(c_stamps))
|
||||
check("...and the deadband still holds the command, so writes are unchanged",
|
||||
d_writes == c_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("an input dies while the meter repeats - the safety claim must still fire")
|
||||
# ⚠️ THE STRONGEST PROPERTY IN SAFETY-12, and the one that makes it a safety fix
|
||||
# rather than a latency fix. The `inputs missing -> 0 W` claim lives INSIDE
|
||||
# cycle() (main.py, the stale_input_s branch and the P_SAFETY claim below it).
|
||||
# Pre-fix, on a meter whose value happened to repeat, cycle() was never called
|
||||
# again - so that claim could not fire AT ALL. The controller held its last
|
||||
# command through an input outage of unbounded length with the status line still
|
||||
# reading "loop -> N W".
|
||||
#
|
||||
# Layer 1 does not cover this either on a `meter_source: off` install: no P1 age
|
||||
# sensor is published (see Controller.publish), so the firmware has nothing to
|
||||
# veto on, and the heartbeat keeps its watchdog fed the whole time.
|
||||
#
|
||||
# stale_input_s is shortened to 3 s here so the outage resolves inside a test
|
||||
# rather than inside a quarter of a minute. The mechanism is the default one.
|
||||
c2_stamps, c2_writes, pre_target, pre_reason = drive(
|
||||
FLAT, NEVER, 10.0, soc_dies_at=4.0, stale_input_s=3)
|
||||
check("pre-fix: a dead input during a constant meter never reaches the safety claim",
|
||||
pre_target != 0.0 and "safety" not in pre_reason)
|
||||
check(f"...so it holds its last command instead ({pre_target:g} W, {pre_reason!r})",
|
||||
pre_target == 220.0)
|
||||
|
||||
d2_stamps, d2_writes, post_target, post_reason = drive(
|
||||
FLAT, FLOOR, 10.0, soc_dies_at=4.0, stale_input_s=3)
|
||||
check("post-fix: the same outage commands 0 W", post_target == 0.0)
|
||||
check(f"...through the safety claim, not by accident ({post_reason!r})",
|
||||
"safety" in post_reason)
|
||||
check("...and the 0 W actually reached the device", 0.0 in d2_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + "; ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -11,6 +11,7 @@ computes the wrong quarter-hour figure whenever the telegram cadence changes.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import json
|
||||
import sys
|
||||
import time
|
||||
from datetime import datetime, timedelta, timezone
|
||||
@@ -18,8 +19,11 @@ from datetime import datetime, timedelta, timezone
|
||||
import aiohttp # already required by app.p1, so this adds no new dependency
|
||||
|
||||
from app.p1 import (
|
||||
P1Error, P1Ingest, HaDsmrSource, QuarterAverager, SOURCE_HA, SOURCE_MQTT,
|
||||
make_sample, parse_mqtt_payload,
|
||||
P1Error, P1Ingest, HaDsmrSource, HaSignedSource, HomeWizardLocalSource,
|
||||
QuarterAverager,
|
||||
SOURCE_HA, SOURCE_HA_SIGNED, SOURCE_HOMEWIZARD, SOURCE_MQTT,
|
||||
build_source, is_enabled, make_sample, parse_homewizard, parse_mqtt_payload,
|
||||
split_signed,
|
||||
)
|
||||
|
||||
fails = []
|
||||
@@ -56,6 +60,25 @@ def raises(name, fn):
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def built(src):
|
||||
"""`src.build()`, with any escaping exception turned into a visible value.
|
||||
|
||||
⚠️ Legibility of a RED, not leniency. build() is contracted to return a bool
|
||||
and to funnel every bad telegram through ingest.reject() - a guard that goes
|
||||
missing (say the "is the net entity cached at all" one) makes it raise
|
||||
instead. That still fails the suite, but by aborting it with a traceback at
|
||||
whichever check happened to run first, which costs the next person ten
|
||||
minutes deciding whether the suite is broken or the code is. Returning the
|
||||
exception makes it compare unequal to True/False, so the NAMED check goes red
|
||||
and says which rule died.
|
||||
"""
|
||||
try:
|
||||
return src.build()
|
||||
except Exception as err: # noqa: BLE001 - a raise here is itself the failure
|
||||
print(f" build() raised {type(err).__name__}: {err}")
|
||||
return err
|
||||
|
||||
|
||||
def sample(net_import, net_export=0.0, at=BASE, phases=1, pi=None, pe=None):
|
||||
return make_sample(SOURCE_HA, net_import, net_export, phases=phases,
|
||||
phase_import_w=pi, phase_export_w=pe,
|
||||
@@ -548,6 +571,726 @@ check("the averager integrated the live stream", live.averager.elapsed_s > 0.2)
|
||||
check("the primed cache let the first telegram build immediately",
|
||||
live.samples == 2 and live.last.import_w == 0.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: one signed entity -> the same two magnitudes")
|
||||
# The meter actually fitted at this house is a HomeWizard P1 publishing ONE
|
||||
# signed sensor. ha_dsmr cannot read it - it wants two unsigned registers and
|
||||
# refuses a negative one, which is every exporting telegram.
|
||||
|
||||
check("a positive reading is import", split_signed(1500.0) == (1500.0, 0.0))
|
||||
check("a negative reading is export", split_signed(-900.0) == (0.0, 900.0))
|
||||
check("zero is a balanced reading, not a missing one",
|
||||
split_signed(0.0) == (0.0, 0.0))
|
||||
check("exactly one magnitude is ever non-zero",
|
||||
all(a == 0.0 or b == 0.0 for a, b in
|
||||
(split_signed(v) for v in (-5710.0, -1.0, 0.0, 1.0, 4384.0))))
|
||||
# ⚠️ The split must not change the number. A control loop steered by a value
|
||||
# that was rounded or clamped on the way in is steered by a different meter.
|
||||
check("the split round-trips the signed value exactly",
|
||||
all(make_sample(SOURCE_HA_SIGNED, *split_signed(v), phases=1).net_w == v
|
||||
for v in (-11763.0, -5710.0, -0.5, 0.0, 0.5, 775.0, 4384.0)))
|
||||
|
||||
raises("a non-numeric signed reading is rejected", lambda: split_signed("n/a"))
|
||||
raises("a signed None is rejected, not read as zero", lambda: split_signed(None))
|
||||
raises("a signed NaN is rejected", lambda: split_signed(float("nan")))
|
||||
raises("a signed infinity is rejected", lambda: split_signed(float("inf")))
|
||||
# ⚠️ This one matters MORE on the signed path than on the unsigned one. On
|
||||
# ha_dsmr the §20 contamination is also caught by "unsigned cannot be negative";
|
||||
# here 64954 arrives as a perfectly well-formed positive signed reading and the
|
||||
# plausibility ceiling is the only thing standing in front of it.
|
||||
raises("the 64954 signed-decode contamination is still rejected",
|
||||
lambda: split_signed(64954.0))
|
||||
raises("...and its negative twin too", lambda: split_signed(-64954.0))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: the sign convention, against real captured readings")
|
||||
# ⚠️ Not a datasheet claim. These are literal values out of
|
||||
# sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json, HA recorder
|
||||
# exports of sensor.p1_meter_active_power at this house, copied here rather than
|
||||
# read from that repo so this file still runs on a laptop with nothing installed
|
||||
# (§17). If the convention were inverted, the physics below would be absurd.
|
||||
|
||||
# 2026-08-23T11:46:52Z - the day's most negative reading, 13:46 local, full sun.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(-5710.0), phases=1)
|
||||
check("the midday PV peak (-5710 W) is EXPORT, not a 5.7 kW draw",
|
||||
s.net_w == -5710.0 and s.export_w == 5710.0 and s.import_w == 0.0)
|
||||
# 2026-08-19T22:00:00Z - midnight local, 20 Aug's file starts here. No sun.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(775.0), phases=1)
|
||||
check("the overnight base load (+775 W) is IMPORT",
|
||||
s.net_w == 775.0 and s.import_w == 775.0 and s.export_w == 0.0)
|
||||
# 2026-08-20T12:20:58Z - 14:20 local, the largest export in either capture.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(-11763.0), phases=1)
|
||||
check("the -11763 W midday extreme is export and survives the ceiling",
|
||||
s.net_w == -11763.0 and s.export_w == 11763.0)
|
||||
# 2026-08-23T10:18:28Z - the largest import in the healthy capture.
|
||||
s = make_sample(SOURCE_HA_SIGNED, *split_signed(4384.0), phases=1)
|
||||
check("the +4384 W peak is import", s.net_w == 4384.0 and s.import_w == 4384.0)
|
||||
# The whole convention in one line: night draws, midday feeds back.
|
||||
check("night is positive and midday is negative, which is the convention",
|
||||
split_signed(775.0)[0] > 0 and split_signed(-5710.0)[1] > 0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed transport: building a sample out of one entity state")
|
||||
|
||||
NET = {"net": "sensor.p1_meter_active_power", "phase_net": []}
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
sig = HaSignedSource(None, ing, NET, token="x")
|
||||
|
||||
check("nothing cached yet builds nothing", built(sig) is False and ing.last is None)
|
||||
sig._absorb("sensor.p1_meter_active_power", "1000")
|
||||
check("one signed entity is a complete telegram on its own",
|
||||
built(sig) is True and ing.net_w == 1000.0)
|
||||
check("the sample is tagged with its own transport",
|
||||
ing.last.source == SOURCE_HA_SIGNED)
|
||||
sig._absorb("sensor.p1_meter_active_power", "-2500")
|
||||
built(sig)
|
||||
check("a negative state lands as a negative net", ing.net_w == -2500.0)
|
||||
|
||||
before = ing.last
|
||||
sig._absorb("sensor.p1_meter_active_power", "unavailable")
|
||||
check("an unavailable signed entity is a parse error", ing.parse_errors == 1)
|
||||
check("an unavailable entity does not build a sample", built(sig) is False)
|
||||
# ⚠️ The rule the whole ticket turns on: a missing reading is MISSING. Resolving
|
||||
# it to 0 W would read as a perfectly balanced house and defeat the staleness
|
||||
# trigger that FW-01's watchdog is built on.
|
||||
check("an unavailable entity leaves the last good sample untouched, not 0 W",
|
||||
ing.last is before and ing.net_w == -2500.0)
|
||||
sig._absorb("sensor.p1_meter_active_power", "unknown")
|
||||
check("an unknown signed entity is treated the same way", ing.parse_errors == 2)
|
||||
sig._absorb("sensor.p1_meter_active_power", "banana")
|
||||
check("a non-numeric signed state is a parse error, not 0 W",
|
||||
ing.parse_errors == 3 and ing.net_w == -2500.0)
|
||||
sig._absorb("sensor.p1_meter_active_power", "64954")
|
||||
check("64954 is refused at the signed transport too",
|
||||
built(sig) is False and ing.parse_errors == 4)
|
||||
sig._absorb("sensor.not_ours", "123")
|
||||
check("an unsubscribed entity is never cached by the signed transport",
|
||||
"sensor.not_ours" not in sig.cache)
|
||||
|
||||
# A rejected reading must not make the age look fresh - the age is what the
|
||||
# firmware watchdog reads, and a rejection is exactly when it must keep climbing.
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
sig = HaSignedSource(None, ing, dict(NET), token="x")
|
||||
ing.submit(make_sample(SOURCE_HA_SIGNED, 1200, 0, phases=1,
|
||||
ingest_mono=time.monotonic() - 20.0))
|
||||
sig._absorb("sensor.p1_meter_active_power", "unavailable")
|
||||
built(sig)
|
||||
check("a rejected reading does not reset the published age",
|
||||
ing.published_age_s > 19 and ing.net_w == 1200.0)
|
||||
ing.submit(make_sample(SOURCE_HA_SIGNED, 1200, 0, phases=1,
|
||||
ingest_mono=time.monotonic() - 40.0))
|
||||
check("...and the age keeps climbing past max_age_s on its own",
|
||||
ing.stale is True and ing.net_w is None)
|
||||
|
||||
# The three-phase reading the TEL-04 survey recorded at this house: L1 +2301 W,
|
||||
# L2 +468 W, L3 -2582 W, netting +187 W. A signed per-phase set splits the same
|
||||
# way, and the exporting phase must still clamp out of the billed figure.
|
||||
ing3 = P1Ingest(phases=3, max_age_s=30.0)
|
||||
NET3 = {"net": "sensor.p1_meter_active_power",
|
||||
"phase_net": ["sensor.p1_l1", "sensor.p1_l2", "sensor.p1_l3"]}
|
||||
sig3 = HaSignedSource(None, ing3, NET3, token="x")
|
||||
for eid, val in (("sensor.p1_meter_active_power", "187"), ("sensor.p1_l1", "2301")):
|
||||
sig3._absorb(eid, val)
|
||||
check("an incomplete signed phase set waits instead of guessing", built(sig3) is False)
|
||||
sig3._absorb("sensor.p1_l2", "468")
|
||||
sig3._absorb("sensor.p1_l3", "-2582")
|
||||
check("a complete signed three-phase set builds", built(sig3) is True)
|
||||
check("signed per-phase entities keep the exporting phase negative",
|
||||
ing3.last.per_phase_w == (2301.0, 468.0, -2582.0))
|
||||
check("per-phase IMPORT clamps the exporting phase to zero",
|
||||
ing3.last.per_phase_import_w == (2301.0, 468.0, 0.0))
|
||||
check("the phase import sum is 2769 W while the connection nets 187 W",
|
||||
sum(ing3.last.per_phase_import_w) == 2769.0 and ing3.last.net_w == 187.0)
|
||||
check("the signed per-phase tuple length matches meter_phases",
|
||||
len(ing3.last.per_phase_w) == ing3.phases == 3)
|
||||
|
||||
sig_bad = HaSignedSource(None, P1Ingest(phases=3, max_age_s=30.0),
|
||||
{"net": "sensor.net", "phase_net": ["sensor.a", "sensor.b"]},
|
||||
token="x")
|
||||
for eid in ("sensor.net", "sensor.a", "sensor.b"):
|
||||
sig_bad._absorb(eid, "100")
|
||||
check("two phases delivered against meter_phases 3 is rejected, not padded",
|
||||
built(sig_bad) is False and sig_bad.ingest.last is None
|
||||
and sig_bad.ingest.parse_errors == 1)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed transport: end to end against a fake Home Assistant")
|
||||
# The transport is a subclass, so this is what proves the INHERITED machinery -
|
||||
# auth, subscribe, the get_states priming rule, the reconnect-emits-nothing
|
||||
# rule - still behaves when only _wanted() and build() were replaced.
|
||||
|
||||
|
||||
async def _e2e_signed():
|
||||
from aiohttp import web
|
||||
import app.p1 as p1mod
|
||||
|
||||
done = asyncio.Event()
|
||||
eid = "sensor.p1_meter_active_power"
|
||||
|
||||
async def fake_ha(request):
|
||||
ws = web.WebSocketResponse()
|
||||
await ws.prepare(request)
|
||||
await ws.send_json({"type": "auth_required", "ha_version": "2026.8"})
|
||||
auth = await ws.receive_json()
|
||||
assert auth["type"] == "auth" and auth["access_token"] == "tok"
|
||||
await ws.send_json({"type": "auth_ok"})
|
||||
sub = await ws.receive_json()
|
||||
assert sub["type"] == "subscribe_events"
|
||||
await ws.send_json({"id": sub["id"], "type": "result", "success": True})
|
||||
get = await ws.receive_json()
|
||||
assert get["type"] == "get_states"
|
||||
await ws.send_json({"id": get["id"], "type": "result", "success": True, "result": [
|
||||
{"entity_id": eid, "state": "775.0"},
|
||||
{"entity_id": "sensor.something_else", "state": "hello"},
|
||||
]})
|
||||
# Two real telegrams, both literal captured values: overnight import,
|
||||
# then the midday export peak.
|
||||
for val in ("775.0", "-5710.0"):
|
||||
await asyncio.sleep(0.5)
|
||||
await ws.send_json({"type": "event", "event": {"data": {
|
||||
"entity_id": eid,
|
||||
"new_state": {"entity_id": eid, "state": val}}}})
|
||||
await asyncio.sleep(0.5)
|
||||
await ws.send_json({"type": "event", "event": {"data": {
|
||||
"entity_id": eid,
|
||||
"new_state": {"entity_id": eid, "state": "unavailable"}}}})
|
||||
await asyncio.sleep(0.5)
|
||||
done.set()
|
||||
return ws
|
||||
|
||||
srv = web.Application()
|
||||
srv.router.add_get("/ws", fake_ha)
|
||||
runner = web.AppRunner(srv)
|
||||
await runner.setup()
|
||||
site = web.TCPSite(runner, "127.0.0.1", 0)
|
||||
await site.start()
|
||||
port = site._server.sockets[0].getsockname()[1]
|
||||
p1mod.WS_URL = f"http://127.0.0.1:{port}/ws"
|
||||
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
async with aiohttp.ClientSession() as sess:
|
||||
src = HaSignedSource(sess, ing, dict(NET), token="tok")
|
||||
task = asyncio.get_running_loop().create_task(src.run())
|
||||
try:
|
||||
await asyncio.wait_for(done.wait(), 20)
|
||||
await asyncio.sleep(0.5)
|
||||
finally:
|
||||
task.cancel()
|
||||
try:
|
||||
await task
|
||||
except asyncio.CancelledError:
|
||||
pass
|
||||
await runner.cleanup()
|
||||
return ing, src
|
||||
|
||||
|
||||
live, wire = asyncio.run(_e2e_signed())
|
||||
# ⚠️ TWO, not three - the same rule as the ha_dsmr e2e. get_states primes the
|
||||
# cache but must never become a sample: after a Core restart it is a
|
||||
# RestoreEntity value of unknown age, and stamping it with ingest_ts=now reports
|
||||
# a fresh meter that may have been dead for an hour.
|
||||
check("ha_signed does not manufacture a sample from cached HA state",
|
||||
live.samples == 2)
|
||||
check("the signed telegrams arrived over a real websocket",
|
||||
live.last.source == SOURCE_HA_SIGNED)
|
||||
check("the final export telegram nets negative, over the wire",
|
||||
live.last.net_w == -5710.0 and live.last.export_w == 5710.0)
|
||||
check("ha_signed subscribes to the one entity and caches nothing else",
|
||||
wire.ids == {"sensor.p1_meter_active_power"}
|
||||
and "sensor.something_else" not in wire.cache)
|
||||
check("a mid-stream unavailable signed state is a parse error, not a sample",
|
||||
live.parse_errors == 1 and live.samples == 2)
|
||||
# ⚠️ And the cached half is DROPPED, so no later telegram can be assembled out
|
||||
# of a value that stopped reporting.
|
||||
check("an unavailable entity is evicted from the cache", wire.cache == {})
|
||||
check("the last good reading survives the unavailable, and is not 0 W",
|
||||
live.net_w == -5710.0)
|
||||
check("the averager integrated the live signed stream", live.averager.elapsed_s > 0.2)
|
||||
# ⚠️ The entity FW-01 waits on. It must be a number here exactly as it is on the
|
||||
# other transports - the house P1 went 51.1 s and 36.2 s between state changes
|
||||
# overnight, and without this the watchdog false-trips the battery to 0 W.
|
||||
check("sensor.p1_sample_age_s is a live number on this transport too",
|
||||
isinstance(live.published_age_s, float) and live.published_age_s >= 0.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("ha_signed: selection by config")
|
||||
|
||||
check("ha_signed is enabled", is_enabled({"meter_source": SOURCE_HA_SIGNED}) is True)
|
||||
# ⚠️ `sel`, not `built` - that name is the build() wrapper defined at the top of
|
||||
# this file, and rebinding it here silently disarms every check appended below
|
||||
# this line. Caught in review: an added check went `TypeError: 'HaSignedSource'
|
||||
# object is not callable` and aborted the suite, which is the exact failure the
|
||||
# wrapper exists to prevent, reintroduced by a name collision.
|
||||
sel = build_source({"meter_source": SOURCE_HA_SIGNED,
|
||||
"p1_net_entity": "sensor.p1_meter_active_power"},
|
||||
P1Ingest(), None, None)
|
||||
check("meter_source ha_signed selects the signed transport",
|
||||
isinstance(sel, HaSignedSource))
|
||||
check("...wired to p1_net_entity, and subscribed to exactly that one entity",
|
||||
sel.ids == {"sensor.p1_meter_active_power"})
|
||||
# ⚠️ The three modes must not bleed into each other: ha_dsmr must keep ignoring
|
||||
# p1_net_entity, or a half-configured install silently reads the wrong sensor.
|
||||
plain = build_source({"meter_source": SOURCE_HA,
|
||||
"p1_import_entity": "sensor.i", "p1_export_entity": "sensor.e",
|
||||
"p1_net_entity": "sensor.p1_meter_active_power"},
|
||||
P1Ingest(), None, None)
|
||||
check("ha_dsmr still selects the unsigned transport and ignores p1_net_entity",
|
||||
type(plain) is HaDsmrSource and plain.ids == {"sensor.i", "sensor.e"})
|
||||
check("meter_source off still selects nothing",
|
||||
build_source({"meter_source": "off"}, P1Ingest(), None, None) is None)
|
||||
check("an unrecognised meter_source selects nothing rather than guessing",
|
||||
build_source({"meter_source": "ha_signd"}, P1Ingest(), None, None) is None)
|
||||
|
||||
# ⚠️ Caught once at startup, not once per telegram. A source that is wired up
|
||||
# wrong otherwise fails in the one way indistinguishable from a healthy source
|
||||
# nobody has sent anything to yet: no samples, a climbing age, the watchdog
|
||||
# holding the battery at 0 W, and nothing in the log saying why.
|
||||
check("a blank p1_net_entity is refused rather than silently never receiving",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": ""},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("...and whitespace does not sneak past it",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": " "},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("a phase list that disagrees with meter_phases is refused at startup",
|
||||
build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n",
|
||||
"p1_phase_net_entities": ["sensor.a", "sensor.b"]},
|
||||
P1Ingest(phases=3), None, None) is None)
|
||||
check("a phase list that agrees with meter_phases is accepted",
|
||||
isinstance(build_source(
|
||||
{"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n",
|
||||
"p1_phase_net_entities": ["sensor.a", "sensor.b", "sensor.c"]},
|
||||
P1Ingest(phases=3), None, None), HaSignedSource))
|
||||
check("no phase list at all is still fine - per-phase billing is optional",
|
||||
isinstance(build_source(
|
||||
{"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n"},
|
||||
P1Ingest(phases=3), None, None), HaSignedSource))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: parsing the meter's own /api/v1/data document")
|
||||
# The same JSON `sim/hwsim.py` serves and the same JSON the real meter at
|
||||
# 192.168.2.250 serves. One SIGNED connection figure plus three signed legs, so
|
||||
# it goes through the same split_signed as ha_signed - the sign convention is
|
||||
# not re-derived on this transport, it is reused.
|
||||
|
||||
|
||||
def hw_doc(w, l1=None, l2=None, l3=None, imp_kwh=1234.567, exp_kwh=890.123):
|
||||
return {"wifi_ssid": "sim", "smr_version": 50, "meter_model": "SIM-P1",
|
||||
"total_power_import_kwh": imp_kwh, "total_power_export_kwh": exp_kwh,
|
||||
"active_power_w": w,
|
||||
"active_power_l1_w": l1, "active_power_l2_w": l2,
|
||||
"active_power_l3_w": l3, "total_gas_m3": 0.0}
|
||||
|
||||
|
||||
s = parse_homewizard(hw_doc(775.0, l1=775.0), 1)
|
||||
check("the overnight base load (+775 W) is import on this transport too",
|
||||
s.net_w == 775.0 and s.import_w == 775.0 and s.export_w == 0.0)
|
||||
check("the sample is tagged homewizard_local", s.source == SOURCE_HOMEWIZARD)
|
||||
s = parse_homewizard(hw_doc(-5710.0, l1=-5710.0), 1)
|
||||
check("the midday PV peak (-5710 W) is export, not a 5.7 kW draw",
|
||||
s.net_w == -5710.0 and s.export_w == 5710.0)
|
||||
check("a single-phase document still yields its one leg", s.per_phase_w == (-5710.0,))
|
||||
|
||||
# The TEL-04 three-phase survey reading, served the HomeWizard way.
|
||||
s = parse_homewizard(hw_doc(187.0, 2301.0, 468.0, -2582.0), 3)
|
||||
check("signed legs keep the exporting phase negative",
|
||||
s.per_phase_w == (2301.0, 468.0, -2582.0))
|
||||
check("per-phase import clamps the exporting leg out of the billed figure",
|
||||
s.per_phase_import_w == (2301.0, 468.0, 0.0))
|
||||
check("the legs sum to 2769 W while the connection nets 187 W",
|
||||
sum(s.per_phase_import_w) == 2769.0 and s.net_w == 187.0)
|
||||
|
||||
# ⚠️ A single-phase HomeWizard serves `active_power_l2_w: null`. Unlike the HA
|
||||
# transports there is no "wait for the rest" case - every field came out of ONE
|
||||
# response, so a missing leg cannot be a STALE leg. Dropping the whole sample
|
||||
# over it would turn a healthy meter into a climbing age, which is the exact
|
||||
# false trip this transport exists to remove.
|
||||
def parsed(doc, phases=1):
|
||||
"""parse_homewizard(), with an escaping exception turned into a visible value.
|
||||
|
||||
Same reason as `built()` above: if the "all legs or none" guard goes missing,
|
||||
parsing raises, and without this the suite aborts on a traceback instead of
|
||||
reddening the NAMED check that says which rule died.
|
||||
"""
|
||||
try:
|
||||
return parse_homewizard(doc, phases)
|
||||
except Exception as err: # noqa: BLE001 - a raise here is itself the failure
|
||||
print(f" parse_homewizard raised {type(err).__name__}: {err}")
|
||||
return err
|
||||
|
||||
|
||||
s = parsed(hw_doc(500.0, l1=500.0), 3)
|
||||
check("a meter serving fewer legs than meter_phases still gives a reading",
|
||||
getattr(s, "net_w", None) == 500.0 and getattr(s, "per_phase_w", "?") is None)
|
||||
check("...and does not fabricate a partial phase tuple",
|
||||
getattr(s, "per_phase_import_w", "?") is None)
|
||||
|
||||
raises("a response that is not a JSON object is rejected",
|
||||
lambda: parse_homewizard([1, 2, 3], 1))
|
||||
raises("a document with no active_power_w is rejected, not read as 0 W",
|
||||
lambda: parse_homewizard({"total_gas_m3": 0.0}, 1))
|
||||
raises("a null active_power_w is rejected", lambda: parse_homewizard(hw_doc(None), 1))
|
||||
raises("a string active_power_w is rejected", lambda: parse_homewizard(hw_doc("775"), 1))
|
||||
raises("a NaN active_power_w is rejected",
|
||||
lambda: parse_homewizard(hw_doc(float("nan")), 1))
|
||||
raises("the 64954 signed-decode contamination is refused here too",
|
||||
lambda: parse_homewizard(hw_doc(64954.0), 1))
|
||||
raises("a non-numeric leg is rejected rather than quietly dropped",
|
||||
lambda: parse_homewizard(hw_doc(600.0, "2000", 0.0, 100.0), 3))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: every HTTP response is an arrival")
|
||||
# THE WHOLE TICKET. sensor.p1_sample_age_s has to mean "time since the meter
|
||||
# REPORTED", not "time since the value CHANGED". Home Assistant cannot express
|
||||
# the first: a repeated reading emits no state_changed, advances last_reported
|
||||
# on neither serialiser, and state_reported cannot be subscribed to at all
|
||||
# ("Event filter is required"). Measured on the ENV-01 rig over 70 s of a frozen
|
||||
# meter and again against the live house over ten repeated readings. Our own
|
||||
# capture of this house's meter goes 42.2 s and 97.0 s between changes, both past
|
||||
# the default meter_max_age_s of 30 - i.e. the age sensor would command 0 W on a
|
||||
# perfectly healthy meter. Polling the meter itself removes that: the response is
|
||||
# the arrival, and the number in it is not consulted.
|
||||
|
||||
|
||||
class _FakeMeter:
|
||||
"""hwsim in eight lines: serves whatever document it is told to, or a fault."""
|
||||
|
||||
def __init__(self, doc=None):
|
||||
self.doc = doc
|
||||
self.status = 200
|
||||
self.body = None # set to raw text to serve something unparseable
|
||||
self.delay = 0.0 # set to seconds to imitate a meter that hangs
|
||||
self.hits = 0
|
||||
|
||||
async def handle(self, request):
|
||||
from aiohttp import web
|
||||
self.hits += 1
|
||||
if self.delay:
|
||||
await asyncio.sleep(self.delay)
|
||||
# ⚠️ web.Response(text=...) defaults to text/plain. That is not just the
|
||||
# "unparseable body" path: fed VALID json it serves a good document under
|
||||
# the wrong mimetype, which is the only way to reach the content_type
|
||||
# guard in poll_once - json_response can never produce it.
|
||||
if self.body is not None:
|
||||
return web.Response(text=self.body, status=self.status)
|
||||
return web.json_response(self.doc, status=self.status)
|
||||
|
||||
|
||||
async def _hw_rig(fn):
|
||||
"""Run `fn(make_source, meter)` against a real HTTP server on localhost."""
|
||||
from aiohttp import web
|
||||
meter = _FakeMeter(hw_doc(350.0, l1=350.0))
|
||||
app = web.Application()
|
||||
app.router.add_get("/api/v1/data", meter.handle)
|
||||
runner = web.AppRunner(app)
|
||||
await runner.setup()
|
||||
site = web.TCPSite(runner, "127.0.0.1", 0)
|
||||
await site.start()
|
||||
port = site._server.sockets[0].getsockname()[1]
|
||||
async with aiohttp.ClientSession() as sess:
|
||||
try:
|
||||
return await fn(sess, port, meter)
|
||||
finally:
|
||||
await runner.cleanup()
|
||||
|
||||
|
||||
async def _arrivals(sess, port, meter):
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
src = HomeWizardLocalSource(sess, ing, "127.0.0.1", port=port, poll_s=1.0)
|
||||
out = {}
|
||||
out["first"] = await src.poll_once()
|
||||
out["stamp1"] = ing.last.ingest_mono
|
||||
# Four more polls of the IDENTICAL document - the meter has not moved a watt.
|
||||
for _ in range(4):
|
||||
await asyncio.sleep(0.05)
|
||||
await src.poll_once()
|
||||
out["ing"], out["src"], out["meter"] = ing, src, meter
|
||||
return out
|
||||
|
||||
|
||||
r = asyncio.run(_hw_rig(_arrivals))
|
||||
ing, src = r["ing"], r["src"]
|
||||
check("a poll of the meter's own API builds a sample",
|
||||
r["first"] is True and ing.net_w == 350.0)
|
||||
# ⚠️ THE acceptance criterion. Five identical readings, five arrivals. On
|
||||
# ha_signed this whole sequence produces exactly ONE state_changed and then
|
||||
# silence, and the age climbs to 30 s on a meter that is answering perfectly.
|
||||
check("five identical readings are five arrivals, not one",
|
||||
ing.samples == 5 and r["meter"].hits == 5 and src.polls == 5)
|
||||
check("an unchanged value still stamps a NEW arrival time",
|
||||
ing.last.ingest_mono > r["stamp1"])
|
||||
check("...so the age resets on a response carrying an unchanged number",
|
||||
ing.published_age_s < 1.0 and ing.stale is False)
|
||||
check("no arrival was ever a parse error", ing.parse_errors == 0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: frozen vs steady, the pair HA cannot separate")
|
||||
# ⚠️ Read this before changing anything here. A frozen meter (hwsim --fault
|
||||
# freeze) answers 200 OK forever with a stale document. It is ARRIVING. So the
|
||||
# age - an arrival detector, correctly - reads fresh on both, and that is not a
|
||||
# defect in the age, it is the definition of the signal. What the local API adds
|
||||
# that Home Assistant never had is the ENERGY REGISTERS: a meter under real load
|
||||
# advances total_power_import_kwh (1 Wh resolution, ~10 s at 350 W) even when the
|
||||
# power figure repeats, and a frozen one does not. That is the discriminator, and
|
||||
# it is exposed as `unchanged_s` - deliberately NOT folded into the age, because
|
||||
# this controller regulates grid power toward ~0 W and at a converged -10 W the
|
||||
# export register needs six minutes to move. Thresholding unchanged_s at 30 s
|
||||
# would rebuild the false-trip limit cycle at the exact operating point we aim
|
||||
# for. See DOCS.md and HomeWizardLocalSource.unchanged_s.
|
||||
|
||||
|
||||
async def _freeze_vs_steady(sess, port, meter):
|
||||
ing_f = P1Ingest(phases=1, max_age_s=30.0)
|
||||
frozen = HomeWizardLocalSource(sess, ing_f, "127.0.0.1", port=port, poll_s=1.0)
|
||||
meter.doc = hw_doc(350.0, l1=350.0) # --fault freeze: never moves
|
||||
for i in range(4):
|
||||
if i:
|
||||
await asyncio.sleep(0.1) # sleep BEFORE, so unchanged_s
|
||||
await frozen.poll_once() # is read the instant a poll lands
|
||||
|
||||
ing_s = P1Ingest(phases=1, max_age_s=30.0)
|
||||
steady = HomeWizardLocalSource(sess, ing_s, "127.0.0.1", port=port, poll_s=1.0)
|
||||
kwh = 1234.567
|
||||
for i in range(4):
|
||||
if i:
|
||||
await asyncio.sleep(0.1)
|
||||
# A steady 350 W house: the power figure repeats, the register climbs.
|
||||
kwh += 0.001
|
||||
meter.doc = hw_doc(350.0, l1=350.0, imp_kwh=round(kwh, 3))
|
||||
await steady.poll_once()
|
||||
return (ing_f, frozen), (ing_s, steady)
|
||||
|
||||
|
||||
(ing_f, frozen), (ing_s, steady) = asyncio.run(_hw_rig(_freeze_vs_steady))
|
||||
check("a frozen meter keeps arriving, so both read the same power",
|
||||
ing_f.net_w == 350.0 and ing_s.net_w == 350.0)
|
||||
# ⚠️ Recorded as a rule, not a shortcoming: the age is an ARRIVAL detector and a
|
||||
# frozen meter genuinely is arriving. Anyone tempted to make the age catch freeze
|
||||
# is about to reintroduce the false trip on a steady house.
|
||||
check("the age cannot separate them, and is fresh on both",
|
||||
ing_f.published_age_s < 1.0 and ing_s.published_age_s < 1.0)
|
||||
check("the frozen meter's measurement stands still", frozen.unchanged_s > 0.25)
|
||||
check("...while the steady meter's energy register keeps advancing",
|
||||
steady.unchanged_s < 0.05)
|
||||
check("so the two ARE separable on the local API, which HA could not do",
|
||||
frozen.unchanged_s > steady.unchanged_s * 3)
|
||||
check("unchanged_s is None before the first response ever lands",
|
||||
HomeWizardLocalSource(None, P1Ingest(), "h").unchanged_s is None)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: a failed poll is a missing reading, never 0 W")
|
||||
|
||||
|
||||
async def _failures(sess, port, meter):
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
src = HomeWizardLocalSource(sess, ing, "127.0.0.1", port=port, poll_s=1.0)
|
||||
await src.poll_once()
|
||||
# Age the good sample by hand so a reset would be unmistakable.
|
||||
ing.submit(make_sample(SOURCE_HOMEWIZARD, 350.0, 0.0, phases=1,
|
||||
ingest_mono=time.monotonic() - 90.0))
|
||||
out = {}
|
||||
meter.status = 500
|
||||
out["http500"] = await src.poll_once()
|
||||
out["conn_after_500"] = src.connected
|
||||
meter.status, meter.body = 200, "<html>gateway</html>"
|
||||
out["notjson"] = await src.poll_once()
|
||||
meter.body = None
|
||||
meter.doc = {"total_gas_m3": 0.0} # 200 OK, no power in it
|
||||
out["nopower"] = await src.poll_once()
|
||||
out["ing"], out["src"] = ing, src
|
||||
|
||||
# And a meter that is not listening at all: `--fault down`.
|
||||
dead = HomeWizardLocalSource(sess, P1Ingest(phases=1, max_age_s=30.0),
|
||||
"127.0.0.1", port=1, poll_s=1.0)
|
||||
out["down"] = await dead.poll_once()
|
||||
out["dead"] = dead
|
||||
return out
|
||||
|
||||
|
||||
r = asyncio.run(_hw_rig(_failures))
|
||||
ing, src = r["ing"], r["src"]
|
||||
check("an HTTP 500 is not a reading", r["http500"] is False)
|
||||
# A source that was connected and then failed must SAY it is disconnected -
|
||||
# otherwise the diagnostic reads healthy while the age climbs, which is exactly
|
||||
# the "connected: True, parse_errors: 0, samples: 0" state the rig recorded.
|
||||
check("a poll that fails clears the connected flag", r["conn_after_500"] is False)
|
||||
check("a 200 OK carrying something that is not JSON is not a reading",
|
||||
r["notjson"] is False)
|
||||
check("a 200 OK with no active_power_w in it is not a reading", r["nopower"] is False)
|
||||
check("a meter that refuses the connection is not a reading",
|
||||
r["down"] is False and r["dead"].connected is False)
|
||||
check("every failure was counted as a parse error", ing.parse_errors == 3)
|
||||
check("...and the transport records the transport-level ones separately",
|
||||
src.poll_errors == 2 and src.polls == 4)
|
||||
# ⚠️ The rule the safety chain rests on. A failed poll must not manufacture a
|
||||
# balanced house, and must not reset the clock the watchdog reads.
|
||||
check("a failed poll does not reset the age", ing.published_age_s > 89)
|
||||
check("a failed poll leaves the last good value in place, and it is not 0 W",
|
||||
ing.last.net_w == 350.0 and ing.stale is True and ing.net_w is None)
|
||||
check("no failed poll ever became a sample", ing.samples == 2)
|
||||
check("a 200 OK marks the transport connected even when its body is refused",
|
||||
src.connected is True)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: a wrong header, a hung meter, a submit that throws")
|
||||
# Three failure shapes that all end the same way if they are mishandled - no
|
||||
# sample, a climbing age, the battery at 0 W - and each of which would send the
|
||||
# operator hunting the wrong device.
|
||||
|
||||
|
||||
async def _header_and_timeout(sess, port, meter):
|
||||
out = {}
|
||||
# Valid JSON under text/plain: exactly what content_type=None is for.
|
||||
meter.body = json.dumps(hw_doc(350.0, l1=350.0))
|
||||
ing = P1Ingest(phases=1, max_age_s=30.0)
|
||||
src = HomeWizardLocalSource(sess, ing, "127.0.0.1", port=port, poll_s=1.0)
|
||||
out["mimetype"] = await src.poll_once()
|
||||
out["ing"] = ing
|
||||
meter.body = None
|
||||
|
||||
# A meter that takes the connection and then does not answer.
|
||||
meter.delay = 0.6
|
||||
ing_t = P1Ingest(phases=1, max_age_s=30.0)
|
||||
slow = HomeWizardLocalSource(sess, ing_t, "127.0.0.1", port=port,
|
||||
poll_s=1.0, timeout_s=0.05)
|
||||
out["timeout"] = await slow.poll_once()
|
||||
out["timeout_err"] = ing_t.last_error
|
||||
meter.delay = 0.0
|
||||
return out
|
||||
|
||||
|
||||
r = asyncio.run(_hw_rig(_header_and_timeout))
|
||||
# ⚠️ A real firmware answering text/plain must not read as a dead meter. Drop
|
||||
# content_type=None from poll_once and this goes red with "unexpected mimetype".
|
||||
check("valid JSON under the wrong Content-Type is still a reading",
|
||||
r["mimetype"] is True and r["ing"].samples == 1 and r["ing"].net_w == 350.0)
|
||||
# ⚠️ str(asyncio.TimeoutError()) is the EMPTY STRING. Without the class-name
|
||||
# fallback the status page reads "last error:" and then nothing, on a hung
|
||||
# meter, at the moment someone is reading that line to find out why the battery
|
||||
# went to 0 W.
|
||||
check("a timed-out poll names the fault instead of logging an empty reason",
|
||||
r["timeout"] is False and "TimeoutError" in (r["timeout_err"] or ""))
|
||||
|
||||
|
||||
async def _submit_rejects(sess, port, meter):
|
||||
"""submit() raising P1Error must be a rejection, not an escaping exception."""
|
||||
class _P1Boom(P1Ingest):
|
||||
def submit(self, sample):
|
||||
raise P1Error("register went backwards")
|
||||
|
||||
ing = _P1Boom(phases=1, max_age_s=30.0)
|
||||
src = HomeWizardLocalSource(sess, ing, "127.0.0.1", port=port, poll_s=1.0)
|
||||
try:
|
||||
ok = await src.poll_once()
|
||||
except Exception as err: # noqa: BLE001 - an escape IS the failure
|
||||
ok = err
|
||||
return ok, ing.parse_errors
|
||||
|
||||
|
||||
ok, errs = asyncio.run(_hw_rig(_submit_rejects))
|
||||
check("a submit that rejects the sample is handled, not left to escape",
|
||||
ok is False and errs == 1)
|
||||
|
||||
|
||||
async def _submit_explodes(sess, port, meter):
|
||||
"""And an UNEXPECTED raise must not kill the poll task for good."""
|
||||
class _Boom(P1Ingest):
|
||||
def submit(self, sample):
|
||||
raise RuntimeError("kaboom")
|
||||
|
||||
src = HomeWizardLocalSource(sess, _Boom(phases=1, max_age_s=30.0),
|
||||
"127.0.0.1", port=port, poll_s=0.05)
|
||||
task = asyncio.create_task(src.run())
|
||||
await asyncio.sleep(0.3)
|
||||
alive = not task.done()
|
||||
task.cancel()
|
||||
# ⚠️ BaseException, and the same reason built() exists: if run() loses its
|
||||
# guard the task is already dead HOLDING the RuntimeError, and awaiting it
|
||||
# re-raises - aborting the whole suite with a traceback instead of reddening
|
||||
# the check that names the rule. The death is what `alive` records; catching
|
||||
# it here is bookkeeping, not leniency.
|
||||
try:
|
||||
await task
|
||||
except BaseException: # noqa: BLE001
|
||||
pass
|
||||
return alive, src.polls
|
||||
|
||||
|
||||
# ⚠️ The silent-death case. A dead poll task fails SAFE - the age climbs and the
|
||||
# controller commands 0 W - but it looks exactly like a dead meter, so the
|
||||
# operator spends the outage power-cycling hardware that was never at fault.
|
||||
alive, polls = asyncio.run(_hw_rig(_submit_explodes))
|
||||
check("a raise inside a poll does not permanently kill the polling task",
|
||||
alive is True and polls > 1)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("homewizard_local: selection by config")
|
||||
|
||||
check("homewizard_local is enabled", is_enabled({"meter_source": SOURCE_HOMEWIZARD}) is True)
|
||||
sel = build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "192.168.2.250"},
|
||||
P1Ingest(), None, None)
|
||||
check("meter_source homewizard_local selects the polling transport",
|
||||
isinstance(sel, HomeWizardLocalSource))
|
||||
# ⚠️ getattr, not attribute access, for the same reason `built()` exists: a
|
||||
# startup guard that goes wrong returns None here, and `None.url` would abort the
|
||||
# suite with a traceback instead of reddening the check that names the rule.
|
||||
check("...pointed at the meter's own local API on the default port",
|
||||
getattr(sel, "url", None) == "http://192.168.2.250:80/api/v1/data")
|
||||
check("the default cadence is the meter's own ~5 s update rate",
|
||||
getattr(sel, "poll_s", None) == 5.0)
|
||||
# ⚠️ The request must not outlive the poll interval: a backlog of queued requests
|
||||
# behind a slow meter would land several arrivals for one measurement.
|
||||
check("the request timeout is held under the poll interval",
|
||||
getattr(sel, "timeout_s", 99) < getattr(sel, "poll_s", 0))
|
||||
|
||||
sel = build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "10.0.0.9:8080"},
|
||||
P1Ingest(), None, None)
|
||||
check("an explicit host:port is honoured, which is how the sim is reached",
|
||||
getattr(sel, "url", None) == "http://10.0.0.9:8080/api/v1/data")
|
||||
sel = build_source({"meter_source": SOURCE_HOMEWIZARD,
|
||||
"p1_host": "http://192.168.2.250/"}, P1Ingest(), None, None)
|
||||
check("a pasted browser URL still resolves to the right host",
|
||||
getattr(sel, "url", None) == "http://192.168.2.250:80/api/v1/data")
|
||||
|
||||
# ⚠️ Caught once at startup, not once per poll - a source wired up wrong
|
||||
# otherwise fails in the one way indistinguishable from a healthy one nobody has
|
||||
# polled yet: no samples, a climbing age, the watchdog at 0 W, nothing in the log.
|
||||
check("a blank p1_host is refused rather than silently never polling",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": ""},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("...and whitespace does not sneak past it",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": " "},
|
||||
P1Ingest(), None, None) is None)
|
||||
check("an unparseable port is refused rather than guessed",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "meter:eighty"},
|
||||
P1Ingest(), None, None) is None)
|
||||
# ⚠️ The age can never be fresher than the poll interval, so a cadence at or past
|
||||
# max_age_s means every reading is stale before its successor arrives: the
|
||||
# controller would sit permanently on missing inputs while the meter is fine.
|
||||
check("a poll cadence at meter_max_age_s is refused",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "m",
|
||||
"meter_poll_s": 30}, P1Ingest(max_age_s=30), None, None) is None)
|
||||
check("...and one past it too",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "m",
|
||||
"meter_poll_s": 45}, P1Ingest(max_age_s=30), None, None) is None)
|
||||
check("a cadence with headroom is accepted",
|
||||
isinstance(build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "m",
|
||||
"meter_poll_s": 5}, P1Ingest(max_age_s=30),
|
||||
None, None), HomeWizardLocalSource))
|
||||
check("a zero cadence is refused rather than spinning",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "m",
|
||||
"meter_poll_s": 0}, P1Ingest(max_age_s=30), None, None) is None)
|
||||
check("a non-numeric cadence is refused",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD, "p1_host": "m",
|
||||
"meter_poll_s": "fast"}, P1Ingest(max_age_s=30), None, None) is None)
|
||||
# The four modes must not bleed into each other.
|
||||
check("ha_signed ignores p1_host and still selects the entity transport",
|
||||
type(build_source({"meter_source": SOURCE_HA_SIGNED, "p1_net_entity": "sensor.n",
|
||||
"p1_host": "192.168.2.250"}, P1Ingest(), None, None))
|
||||
is HaSignedSource)
|
||||
check("homewizard_local ignores p1_net_entity and needs its own host",
|
||||
build_source({"meter_source": SOURCE_HOMEWIZARD,
|
||||
"p1_net_entity": "sensor.n"}, P1Ingest(), None, None) is None)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the age sensor must not exist when P1 is off")
|
||||
# ⚠️ This is a fleet-wide regression guard, not a nicety. The ESP32 watchdog
|
||||
@@ -556,7 +1299,6 @@ print("the age sensor must not exist when P1 is off")
|
||||
# age were published with meter_source off it would climb past 30 s on every
|
||||
# existing install within half a minute and pin the inverter at 0 W forever.
|
||||
|
||||
from app.p1 import is_enabled # noqa: E402
|
||||
from app.mqtt import SENSORS, MqttPublisher # noqa: E402
|
||||
|
||||
check("meter_source off is disabled", is_enabled({"meter_source": "off"}) is False)
|
||||
@@ -564,6 +1306,8 @@ check("a missing meter_source is disabled", is_enabled({}) is False)
|
||||
check("an empty meter_source is disabled", is_enabled({"meter_source": ""}) is False)
|
||||
check("ha_dsmr is enabled", is_enabled({"meter_source": SOURCE_HA}) is True)
|
||||
check("mqtt_p1 is enabled", is_enabled({"meter_source": SOURCE_MQTT}) is True)
|
||||
check("homewizard_local is enabled here too",
|
||||
is_enabled({"meter_source": SOURCE_HOMEWIZARD}) is True)
|
||||
|
||||
# The entity id SAFETY-01's firmware subscribes to, pinned by object_id.
|
||||
row = [s for s in SENSORS if s[0] == "p1_age"]
|
||||
@@ -602,6 +1346,17 @@ check("with P1 on the age sensor IS announced",
|
||||
from app.main import Controller # noqa: E402
|
||||
|
||||
|
||||
def _never():
|
||||
"""A stop Event these publish-only tests never set.
|
||||
|
||||
`stop` is a REQUIRED keyword argument (CFG-01): a Controller that cannot
|
||||
stop itself used to be the default one, and on the late-refusal path that
|
||||
meant a live process with no control loop and no exit. These cases only call
|
||||
publish(), so any Event will do - but they may not skip it.
|
||||
"""
|
||||
return asyncio.Event()
|
||||
|
||||
|
||||
class _Store:
|
||||
data = {}
|
||||
|
||||
@@ -624,18 +1379,80 @@ class _Pub:
|
||||
|
||||
|
||||
pub_off = _Pub()
|
||||
Controller({"meter_source": "off"}, None, _Store(), pub_off).publish()
|
||||
Controller({"meter_source": "off"}, None, _Store(), pub_off, stop=_never()).publish()
|
||||
check("with P1 off, p1_age is absent from the published payload",
|
||||
"p1_age" not in pub_off.last)
|
||||
check("...while the normal status keys are still published",
|
||||
"setpoint" in pub_off.last and "grid" in pub_off.last)
|
||||
|
||||
pub_on = _Pub()
|
||||
Controller({"meter_source": SOURCE_HA}, None, _Store(), pub_on).publish()
|
||||
Controller({"meter_source": SOURCE_HA}, None, _Store(), pub_on, stop=_never()).publish()
|
||||
check("with P1 on, p1_age is published", "p1_age" in pub_on.last)
|
||||
check("...as a number, so has_state() becomes true only once we feed it",
|
||||
isinstance(pub_on.last["p1_age"], float))
|
||||
|
||||
# ⚠️ And on ha_signed identically - this is the whole reason TEL-04 exists. The
|
||||
# age sensor is a hard prerequisite for the FW-01 flash, and it has to appear on
|
||||
# the transport that can actually read the meter in this house.
|
||||
pub_sig = _Pub()
|
||||
Controller({"meter_source": SOURCE_HA_SIGNED}, None, _Store(), pub_sig, stop=_never()).publish()
|
||||
check("with ha_signed selected, p1_age is published too",
|
||||
"p1_age" in pub_sig.last and isinstance(pub_sig.last["p1_age"], float))
|
||||
|
||||
# ⚠️ And on homewizard_local, where it is the one age FW-01 may actually
|
||||
# threshold - every other transport's age measures when the VALUE changed.
|
||||
pub_hw = _Pub()
|
||||
Controller({"meter_source": SOURCE_HOMEWIZARD}, None, _Store(), pub_hw, stop=_never()).publish()
|
||||
check("with homewizard_local selected, p1_age is published",
|
||||
"p1_age" in pub_hw.last and isinstance(pub_hw.last["p1_age"], float))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("unchanged_s has somewhere an operator can read it")
|
||||
# ⚠️ The counter is deliberately NOT thresholded and NOT folded into the age -
|
||||
# at the converged -10 W this controller aims for, a 1 Wh register needs six
|
||||
# minutes to move, so any limit false-trips at the target operating point. That
|
||||
# refusal only holds up if a HUMAN can interpret the number instead, and DOCS.md
|
||||
# tells them "the transport tracks it as unchanged_s". Before this, nothing ever
|
||||
# read the transport object back: connected, polls, poll_errors and unchanged_s
|
||||
# were all write-only, and the documented signal existed nowhere an operator
|
||||
# could see it.
|
||||
|
||||
|
||||
def p1_rows(ctl):
|
||||
"""The P1 status line(s), or the exception that stopped checks() making one.
|
||||
|
||||
Same reason as built(): a status line that raises would abort the suite with
|
||||
a traceback instead of reddening the check that names the rule.
|
||||
"""
|
||||
try:
|
||||
return [c["text"] for c in ctl.checks() if c["text"].startswith("P1 meter")]
|
||||
except Exception as err: # noqa: BLE001 - a raise here is itself the failure
|
||||
print(f" checks() raised {type(err).__name__}: {err}")
|
||||
return err
|
||||
|
||||
|
||||
def _fed(source):
|
||||
ctl = Controller({"meter_source": source}, None, _Store(), _Pub(), stop=_never())
|
||||
ctl.p1.submit(make_sample(source, 350.0, 0.0, phases=1,
|
||||
ingest_mono=time.monotonic()))
|
||||
return ctl
|
||||
|
||||
|
||||
hw_ctl = _fed(SOURCE_HOMEWIZARD)
|
||||
hw_src = HomeWizardLocalSource(None, hw_ctl.p1, "127.0.0.1")
|
||||
hw_src._note(hw_doc(350.0, l1=350.0))
|
||||
hw_ctl.p1_source = hw_src # what amain() does once the transport exists
|
||||
rows = p1_rows(hw_ctl)
|
||||
check("the healthy P1 status line reports the transport's unchanged_s",
|
||||
isinstance(rows, list) and len(rows) == 1 and "unchanged" in rows[0])
|
||||
|
||||
# ⚠️ getattr, not attribute access: p1_source is None until amain() builds one,
|
||||
# and ha_dsmr/ha_signed/mqtt_p1 have no such counter at all. Reaching for it
|
||||
# directly would turn the whole status page into a 500 on every other transport.
|
||||
ha_rows = p1_rows(_fed(SOURCE_HA))
|
||||
check("...and the line is unharmed on a transport that has no such counter",
|
||||
isinstance(ha_rows, list) and len(ha_rows) == 1 and "unchanged" not in ha_rows[0])
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} of {total} FAILED: {', '.join(fails)}")
|
||||
|
||||
@@ -0,0 +1,318 @@
|
||||
"""Runnable check for the startup gate. `python3 test_validate.py`
|
||||
|
||||
Two halves, and the second is the one that matters. The first asserts that the
|
||||
three refusable configurations are refused. The second asserts that everything
|
||||
on validate.py's "deliberately not refused" list still STARTS - because the way
|
||||
a validator dies is not by missing a fault, it is by refusing something harmless
|
||||
until somebody deletes the call.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import sys
|
||||
|
||||
from app.validate import (
|
||||
ACTUATOR_WRITE_KEYS, FIRMWARE_INGEST_VETO_S, ConfigRefused, refuse,
|
||||
validate_startup_config,
|
||||
)
|
||||
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def base(**over):
|
||||
"""A configuration that must start. Everything else is this, spoilt."""
|
||||
o = {"setpoint_entity": "number.goodwe_setpoint", "max_w": 2000,
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off"}
|
||||
o.update(over)
|
||||
return o
|
||||
|
||||
|
||||
def why(problems, needle):
|
||||
return any(needle in p for p in problems)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the baseline must start, or nothing below means anything")
|
||||
check("a good config with a 5000 W device is accepted",
|
||||
validate_startup_config(base(), -5000, 5000) == [])
|
||||
check("...and with no device reachable yet, too",
|
||||
validate_startup_config(base(), None, None) == [])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("1. max_w against the device's own rating")
|
||||
# ⚠️ THE ORIGINAL BUG. main.py used to log 'the device wins' and run anyway,
|
||||
# with write_setpoint() clamping, so the configured ceiling was never the real
|
||||
# one and the only evidence had scrolled off the log.
|
||||
p = validate_startup_config(base(max_w=8000), -5000, 5000)
|
||||
check("max_w above the device maximum is refused", len(p) == 1)
|
||||
check("...and the message names the configured value", why(p, "8000"))
|
||||
check("...and the device's value", why(p, "5000"))
|
||||
check("...and says which one wins", why(p, "THE DEVICE WINS"))
|
||||
check("max_w exactly at the device maximum is fine",
|
||||
validate_startup_config(base(max_w=5000), -5000, 5000) == [])
|
||||
check("max_w under it is fine",
|
||||
validate_startup_config(base(max_w=2000), -5000, 5000) == [])
|
||||
# The charge side is a separate rail and an asymmetric device is legal.
|
||||
p = validate_startup_config(base(max_w=4000), -2500, 5000)
|
||||
check("a max_w the device cannot take on the CHARGE side is refused too",
|
||||
len(p) == 1 and why(p, "charge side"))
|
||||
check("...naming the device's floor", why(p, "-2500"))
|
||||
# ⚠️ Not guessed at: the entity may simply not have booted yet. run_control()
|
||||
# re-runs this the moment the real rating arrives.
|
||||
check("an unreachable device skips the range check rather than assuming",
|
||||
validate_startup_config(base(max_w=8000), None, None) == [])
|
||||
check("a non-numeric max_w is refused",
|
||||
why(validate_startup_config(base(max_w="lots"), -5000, 5000), "not a number"))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("2. an actuator to write to")
|
||||
# A controller with no actuator: write_setpoint() returns on the blank entity,
|
||||
# so no rating is read, no heartbeat is sent, layer 1 pins the inverter at 0 W,
|
||||
# and the add-on looks perfectly healthy the whole time.
|
||||
for blank in ("", " ", None):
|
||||
p = validate_startup_config(base(setpoint_entity=blank), None, None)
|
||||
check(f"setpoint_entity {blank!r} is refused", len(p) == 1)
|
||||
check("...and the message says why it is dangerous rather than untidy",
|
||||
why(validate_startup_config(base(setpoint_entity=""), None, None),
|
||||
"heartbeat"))
|
||||
# specs §1.5: two writers on one actuator is not expressible in this schema.
|
||||
check("there is exactly one way to reach the actuator",
|
||||
ACTUATOR_WRITE_KEYS == ("setpoint_entity",))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("3. a meter that can never read")
|
||||
# ⚠️ These predicates belong to p1.validate_meter_options(), which build_source()
|
||||
# also uses. Asserted here to prove the gate actually consults it - one entry
|
||||
# point, not two.
|
||||
check("meter_source off asks nothing of the P1 keys",
|
||||
validate_startup_config(base(meter_source="off"), -5000, 5000) == [])
|
||||
check("homewizard_local with no p1_host is refused",
|
||||
why(validate_startup_config(base(meter_source="homewizard_local"),
|
||||
-5000, 5000), "p1_host"))
|
||||
check("...and with a host it is accepted",
|
||||
validate_startup_config(base(meter_source="homewizard_local",
|
||||
p1_host="192.168.2.250"), -5000, 5000) == [])
|
||||
check("a poll cadence at meter_max_age_s is refused at STARTUP, not just disabled",
|
||||
why(validate_startup_config(base(meter_source="homewizard_local",
|
||||
p1_host="m", meter_poll_s=30,
|
||||
meter_max_age_s=30), -5000, 5000),
|
||||
"meter_max_age_s"))
|
||||
check("ha_signed with no p1_net_entity is refused",
|
||||
why(validate_startup_config(base(meter_source="ha_signed"), -5000, 5000),
|
||||
"p1_net_entity"))
|
||||
check("a phase list disagreeing with meter_phases is refused",
|
||||
why(validate_startup_config(base(meter_source="ha_signed",
|
||||
p1_net_entity="sensor.n", meter_phases=3,
|
||||
p1_phase_net_entities=["a", "b"]),
|
||||
-5000, 5000), "phase-count"))
|
||||
check("mqtt_p1 with no topic is refused",
|
||||
why(validate_startup_config(base(meter_source="mqtt_p1"), -5000, 5000),
|
||||
"meter_mqtt_topic"))
|
||||
check("ha_dsmr with only half its entities is refused",
|
||||
why(validate_startup_config(base(meter_source="ha_dsmr",
|
||||
p1_import_entity="sensor.i"), -5000, 5000),
|
||||
"p1_export_entity"))
|
||||
check("a misspelt meter_source is refused rather than silently ignored",
|
||||
why(validate_startup_config(base(meter_source="ha_signd"), -5000, 5000),
|
||||
"is not one of"))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("4. meter_max_age_s against the firmware's compile-time veto")
|
||||
# ⚠️ The schema allows int(5,300); the firmware's threshold is baked in at 30 s
|
||||
# and wins silently. Same shape as the max_w case: a configured bound overridden
|
||||
# by a lower layer, with nothing saying so.
|
||||
hw = dict(meter_source="homewizard_local", p1_host="m")
|
||||
p = validate_startup_config(base(**hw, meter_max_age_s=120), -5000, 5000)
|
||||
check("a meter_max_age_s above the firmware veto is refused", len(p) == 1)
|
||||
check("...naming the configured value", why(p, "120"))
|
||||
check("...naming the firmware's value", why(p, "30"))
|
||||
check("...and saying which one wins", why(p, "THE FIRMWARE WINS"))
|
||||
check("the tested pair 30/30 is accepted",
|
||||
validate_startup_config(base(**hw, meter_max_age_s=30), -5000, 5000) == [])
|
||||
check("one second above it is refused",
|
||||
validate_startup_config(base(**hw, meter_max_age_s=31), -5000, 5000) != [])
|
||||
# Below the veto the add-on gives up FIRST, which is fail-safe and visible on
|
||||
# its own status page. Only above is the silent case.
|
||||
check("below the veto is fine - the add-on being stricter is not a conflict",
|
||||
validate_startup_config(base(**hw, meter_max_age_s=10,
|
||||
meter_poll_s=4), -5000, 5000) == [])
|
||||
# ⚠️ Scope: meter_max_age_s is read by nothing but P1Ingest, and the veto keys
|
||||
# off a sensor only published when ingestion runs. With the meter off it governs
|
||||
# nothing, so refusing would be pure trivia.
|
||||
check("with meter_source off the number governs nothing and is not refused",
|
||||
validate_startup_config(base(meter_source="off", meter_max_age_s=300),
|
||||
-5000, 5000) == [])
|
||||
check("the constant is the firmware's, not a rounded guess",
|
||||
FIRMWARE_INGEST_VETO_S == 30.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("max_w must be a positive magnitude")
|
||||
# Schema-blocked on a real install, but validate_startup_config() is also
|
||||
# sim/inject.py's entry point and can be handed any dict at all.
|
||||
for bad in (0, -1, -2000):
|
||||
p = validate_startup_config(base(max_w=bad), -5000, 5000)
|
||||
check(f"max_w {bad} is refused", len(p) == 1 and why(p, "must be positive"))
|
||||
check("...and the message explains it would read as a trip, not a mistake",
|
||||
why(validate_startup_config(base(max_w=0), -5000, 5000), "contradiction"))
|
||||
# ⚠️ SAFETY-02 changed what this case has to say, and the change is real rather
|
||||
# than bookkeeping: with a 1 W ceiling the default 300 W sign-disagreement
|
||||
# threshold is unreachable, so rule 5 refuses - correctly, because the watchdog
|
||||
# would report itself armed while being incapable of firing. What this check is
|
||||
# FOR is "a positive max_w is not itself a refusal", so it now names a sign
|
||||
# threshold the ceiling can actually reach, and the interaction gets its own
|
||||
# check below.
|
||||
check("the smallest sane max_w still starts",
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5), -5000, 5000) == [])
|
||||
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
|
||||
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("what must NOT be refused - a validator that fires on trivia gets deleted")
|
||||
# DOCS.md: the arbiter's `supervised` limit still binds the wire to +-max_w, so
|
||||
# the only cost of the extra headroom is unwind latency after saturation.
|
||||
check("integrator_max_w above max_w warns but starts",
|
||||
validate_startup_config(base(max_w=2000, integrator_max_w=9000),
|
||||
-5000, 5000) == [])
|
||||
check("integrator_max_w 0 (follow max_w) starts",
|
||||
validate_startup_config(base(integrator_max_w=0), -5000, 5000) == [])
|
||||
# Fail-safe AND already a red NOT READY banner naming the entity: a refusal on
|
||||
# top of that adds nothing an operator can act on.
|
||||
check("a missing soc_entity is left to the readiness banner",
|
||||
validate_startup_config(base(soc_entity=""), -5000, 5000) == [])
|
||||
check("a missing batt_entity likewise",
|
||||
validate_startup_config(base(batt_entity=""), -5000, 5000) == [])
|
||||
# The transient case. ESPHome is routinely not up when the add-on boots, and
|
||||
# refusing here would turn a device that arrives late into a restart loop.
|
||||
check("a setpoint entity that is configured but not yet found starts",
|
||||
validate_startup_config(base(), None, None) == [])
|
||||
check("meter_poll_s with thin but non-zero headroom starts",
|
||||
validate_startup_config(base(meter_source="homewizard_local", p1_host="m",
|
||||
meter_poll_s=20, meter_max_age_s=30),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the refusal must be legible as a refusal, not as a crash")
|
||||
p = validate_startup_config(base(max_w=8000, setpoint_entity=""), -5000, 5000)
|
||||
check("several problems are all reported, not just the first", len(p) >= 1)
|
||||
refuse(p) # prints the banner; the eye is the assertion for its wording
|
||||
err = ConfigRefused(p)
|
||||
check("ConfigRefused carries every problem", err.problems == p)
|
||||
check("...and str() names one of them", str(err) == p[0])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the LATE refusal, when the device only shows up after the gate has run")
|
||||
# ⚠️ This path had no test at all and no live demonstration - the review's
|
||||
# catch. ESPHome is routinely not up when the add-on boots, so hass.limits()
|
||||
# returns (None, None), the range checks are skipped, and run_control() is the
|
||||
# first place the device's real rating is ever known. Everything below is about
|
||||
# what happens when it turns out to conflict.
|
||||
from app.main import Controller # noqa: E402
|
||||
|
||||
|
||||
class _LateHass:
|
||||
"""Reports the range only run_control() gets to see."""
|
||||
|
||||
def __init__(self, lo, hi):
|
||||
self.lo, self.hi = lo, hi
|
||||
self.writes = []
|
||||
|
||||
async def limits(self, entity):
|
||||
return (self.lo, self.hi, 1.0)
|
||||
|
||||
async def number(self, *a, **k):
|
||||
return 0.0
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(value)
|
||||
return True
|
||||
|
||||
|
||||
class _Store2:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
|
||||
class _Pub2:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
def late(opts_over, lo, hi):
|
||||
"""Drive run_control() against a device that only reports (lo, hi) now.
|
||||
|
||||
⚠️ Returns whether run_control() EXITED ON ITS OWN. That is the assertion
|
||||
that matters: on a refusal it must return without entering the while loop,
|
||||
and on a clean config it must not return at all. So the clean case is stopped
|
||||
from outside after it has had time to write, rather than waited on - a
|
||||
wait_for() here would just time out, which is the correct behaviour dressed
|
||||
up as a failure.
|
||||
"""
|
||||
async def go():
|
||||
stop = asyncio.Event()
|
||||
hass = _LateHass(lo, hi)
|
||||
# A device narrower than the shipped 5000 W schema ceiling is exactly
|
||||
# the case that cannot be reached through the Supervisor on the live
|
||||
# install, so it is reached here instead.
|
||||
c = Controller(base(**opts_over), hass, _Store2(), _Pub2(), stop=stop)
|
||||
c.auto = True
|
||||
task = asyncio.create_task(c.run_control())
|
||||
for _ in range(30): # up to ~3 s
|
||||
if task.done():
|
||||
break
|
||||
await asyncio.sleep(0.1)
|
||||
exited = task.done()
|
||||
if not exited:
|
||||
c.stopping = True
|
||||
await asyncio.wait_for(task, timeout=5)
|
||||
return c, stop, hass, exited
|
||||
return asyncio.run(go())
|
||||
|
||||
c, stop, hass, exited = late({"max_w": 5000}, -3600.0, 3600.0)
|
||||
check("a device narrower than max_w, discovered late, is refused",
|
||||
c.refused is not None and len(c.refused) == 1)
|
||||
check("...naming both values", why(c.refused, "5000") and why(c.refused, "3600"))
|
||||
check("...signalling amain to wind down", stop.is_set())
|
||||
check("...and returning instead of looping forever", exited)
|
||||
# The whole point: run_control() must not fall through into the while loop. A
|
||||
# single write here would mean it commanded the inverter under a config it had
|
||||
# just declared unusable.
|
||||
check("...having never entered the control loop, so it wrote nothing",
|
||||
hass.writes == [])
|
||||
check("...and it is recorded in the event log an operator reads",
|
||||
any("REFUSED" in e for e in c.events))
|
||||
|
||||
# The same path when there is no conflict: it must NOT refuse, and it must
|
||||
# actually regulate - asserted by a write reaching the device, not by absence.
|
||||
c2, stop2, hass2, exited2 = late({"max_w": 2000}, -5000.0, 5000.0)
|
||||
check("a late device that agrees does not trip the re-check", c2.refused is None)
|
||||
check("...and the control loop runs, writing to the device", hass2.writes != [])
|
||||
check("...and does not signal a shutdown", not stop2.is_set() and not exited2)
|
||||
|
||||
# ⚠️ THE FOOTGUN THE REVIEW FOUND. `stop` used to default to None, so this
|
||||
# construction was legal and the refusal path then returned into a live process
|
||||
# with no control loop, no exit and no further output.
|
||||
try:
|
||||
Controller(base(), _LateHass(-5000.0, 5000.0), _Store2(), _Pub2())
|
||||
check("a Controller with no stop Event is rejected at construction", False)
|
||||
except TypeError:
|
||||
check("a Controller with no stop Event is rejected at construction", True)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + "; ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -0,0 +1,248 @@
|
||||
"""Runnable check for the sign-disagreement watchdog. `python3 test_watchdog.py`
|
||||
|
||||
Every case here is either a fault this must catch or a piece of NORMAL behaviour
|
||||
it must not mistake for one. The second list is the longer one on purpose: an
|
||||
alarm that fires on ordinary operation is worse than no alarm, because the next
|
||||
person switches it off.
|
||||
|
||||
The headline validation is not here - it is `sim/replay_sign.py` in the infra
|
||||
repo, which drives this module over the two captured bus days. This file is the
|
||||
table-driven half: boundaries, timers, the latch, and the arming gate.
|
||||
"""
|
||||
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.watchdog import SignWatchdog, SignWatchdogConfig
|
||||
|
||||
fails = []
|
||||
T0 = datetime(2026, 8, 20, 15, 0, 0, tzinfo=timezone.utc)
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def drive(samples, cfg=None, following=True):
|
||||
"""Feed (offset_s, commanded_w, grid_w) tuples. Returns (wd, trip_offset)."""
|
||||
wd = SignWatchdog(cfg)
|
||||
trip_at = None
|
||||
for item in samples:
|
||||
offset, cmd, grid = item[0], item[1], item[2]
|
||||
f = item[3] if len(item) > 3 else following
|
||||
if wd.evaluate(cmd, grid, f, T0 + timedelta(seconds=offset)) and trip_at is None:
|
||||
trip_at = offset
|
||||
return wd, trip_at
|
||||
|
||||
|
||||
def opposed(duration_s, step=5, cmd=-1000, grid=1500, following=True, start=0):
|
||||
return [(start + t, cmd, grid, following)
|
||||
for t in range(0, int(duration_s) + 1, step)]
|
||||
|
||||
|
||||
print("the fault it exists to catch")
|
||||
wd, at = drive(opposed(300))
|
||||
check("charging into an importing house trips", wd.tripped)
|
||||
check("and trips at 180 s, not before", at == 180)
|
||||
check("the reason names both signals", "-1000" in wd.reason and "+1500" in wd.reason)
|
||||
print(f" e.g. {wd.reason!r}")
|
||||
|
||||
wd, at = drive(opposed(300, cmd=2000, grid=-2000))
|
||||
check("discharging into an exporting house trips too", wd.tripped and at == 180)
|
||||
|
||||
print()
|
||||
print("the boundaries")
|
||||
wd, _ = drive(opposed(600, cmd=-300, grid=1500))
|
||||
check("300 W exactly does NOT qualify (strictly greater)", not wd.tripped)
|
||||
wd, _ = drive(opposed(600, cmd=-301, grid=1500))
|
||||
check("301 W does", wd.tripped)
|
||||
wd, _ = drive(opposed(600, cmd=-1000, grid=300))
|
||||
check("a 300 W meter does not qualify either", not wd.tripped)
|
||||
wd, _ = drive(opposed(175))
|
||||
check("175 s of disagreement does not trip", not wd.tripped)
|
||||
wd, _ = drive(opposed(180))
|
||||
check("180 s does (>= hold_s)", wd.tripped)
|
||||
|
||||
print()
|
||||
print("continuity - the rule that produced zero false positives on real data")
|
||||
broken = opposed(175) + [(180, -1000, -1500)] + opposed(175, start=185)
|
||||
wd, _ = drive(broken)
|
||||
check("179 s, one agreeing sample, then 175 s more: no trip", not wd.tripped)
|
||||
check("and the window really was reset", wd.disagree_since is not None)
|
||||
long_enough = broken + opposed(200, start=365)
|
||||
wd, _ = drive(long_enough)
|
||||
check("but a full 180 s after the reset does trip", wd.tripped)
|
||||
|
||||
print()
|
||||
print("things that are NOT faults")
|
||||
# The load-step transient. Measured on the healthy capture: longest 30 s.
|
||||
wd, _ = drive(opposed(30) + [(35 + t, 800, 900) for t in range(0, 300, 5)])
|
||||
check("a 30 s load-step crossover does not trip", not wd.tripped)
|
||||
|
||||
# SoC 10 %, Standby, declining a 1350 W discharge. The battery does nothing, so
|
||||
# the meter stays where it was and the command agrees with it.
|
||||
wd, _ = drive([(t, 1350, 1350) for t in range(0, 900, 5)])
|
||||
check("a battery refusing a discharge command cannot trip it", not wd.tripped)
|
||||
|
||||
# A frozen meter drives command and reading into agreement, not disagreement.
|
||||
wd, _ = drive([(t, 800, 800) for t in range(0, 900, 5)])
|
||||
check("a frozen meter cannot trip it", not wd.tripped)
|
||||
|
||||
# Maintenance grid charge: 2500 W of charge against an importing house, for
|
||||
# hours. Opposed, both huge - and entirely correct.
|
||||
wd, _ = drive(opposed(7200, cmd=-2500, grid=3000, following=False))
|
||||
check("two hours of maintenance grid charge does not trip", not wd.tripped)
|
||||
check("and the timer never even started", wd.disagree_since is None)
|
||||
|
||||
wd, _ = drive([(t, -1000, None) for t in range(0, 900, 5)])
|
||||
check("a missing meter reading does not trip", not wd.tripped)
|
||||
wd, _ = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
|
||||
check("a missing reading mid-window RESETS it rather than accumulating",
|
||||
wd.tripped and wd.disagree_since is not None)
|
||||
wd, at = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
|
||||
check("...so the trip lands 180 s after the gap, not after 180 s total",
|
||||
at == 365)
|
||||
|
||||
wd, _ = drive([(t, 0.0, 3000) for t in range(0, 900, 5)])
|
||||
check("a 0 W command is not a wrong-direction command", not wd.tripped)
|
||||
|
||||
print()
|
||||
print("the latch")
|
||||
wd, _ = drive(opposed(200))
|
||||
check("tripped after the fault", wd.tripped)
|
||||
# The trip commands 0 W, which removes the command side of the comparison.
|
||||
for t in range(200, 900, 5):
|
||||
wd.evaluate(0.0, 3000, True, T0 + timedelta(seconds=t))
|
||||
check("stays tripped once the command is zeroed", wd.tripped)
|
||||
for t in range(900, 1500, 5):
|
||||
wd.evaluate(1000, 1000, True, T0 + timedelta(seconds=t))
|
||||
check("stays tripped even once everything looks healthy again", wd.tripped)
|
||||
wd.reset()
|
||||
check("reset() is the only way out", not wd.tripped and wd.disagree_since is None)
|
||||
check("and the reason is cleared with it", wd.reason == "")
|
||||
|
||||
print()
|
||||
print("the thresholds are configuration, not constants")
|
||||
cfg = SignWatchdogConfig(min_w=800.0, hold_s=60.0)
|
||||
wd, at = drive(opposed(300, cmd=-1000, grid=1500), cfg=cfg)
|
||||
check("a 60 s hold trips at 60 s", wd.tripped and at == 60)
|
||||
wd, _ = drive(opposed(600, cmd=-700, grid=1500), cfg=cfg)
|
||||
check("an 800 W gate ignores a 700 W command", not wd.tripped)
|
||||
|
||||
print()
|
||||
print("the configuration that would disarm it is refused")
|
||||
from app.validate import validate_startup_config # noqa: E402
|
||||
|
||||
base = {"setpoint_entity": "number.sp", "meter_source": "off",
|
||||
"meter_phases": 1, "meter_max_age_s": 30}
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 300},
|
||||
-5000, 5000)
|
||||
check("300 W under a 2000 W ceiling is accepted", p == [])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 2000},
|
||||
-5000, 5000)
|
||||
check("a threshold AT max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
p = validate_startup_config({**base, "max_w": 500, "sign_disagree_w": 3000},
|
||||
-5000, 5000)
|
||||
check("a threshold above max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 1999},
|
||||
-5000, 5000)
|
||||
check("one watt under the ceiling is reachable, so accepted", p == [])
|
||||
|
||||
print()
|
||||
print("end to end: the trip is COMMAND ZERO, not alarm-only")
|
||||
# ⚠️ THE FAULT INJECTED HERE IS A NEGATIVE GAIN, and that is not a contrivance -
|
||||
# it is the minimal faithful model of what this watchdog is for. The check
|
||||
# compares the loop's OUTPUT DIRECTION against the INPUT STATE it was regulating,
|
||||
# so what it detects is a loop whose two ends have become decoupled in sign: a
|
||||
# gain, a claim or a strategy with its polarity inverted, or an integrator so far
|
||||
# wound up that unwinding takes minutes. (Illusmart's was the last one: it
|
||||
# reached -14 768 W against a +-5000 W rail while writing once every 20-60 s, and
|
||||
# that arithmetic alone is 5-15 minutes of wrong-direction command.)
|
||||
#
|
||||
# `gain` is float(0.05,1.0) in the schema, so this is not a reachable
|
||||
# configuration - it is a stand-in for a code regression, which is the case a
|
||||
# unit test can actually hold the line on.
|
||||
import asyncio # noqa: E402
|
||||
|
||||
from app.main import Controller # noqa: E402
|
||||
|
||||
|
||||
class _Hass:
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
# A house importing 2000 W, steadily, whatever the battery does.
|
||||
return {"sensor.grid": 2000.0, "sensor.soc": 50.0,
|
||||
"sensor.batt": 0.0}.get(entity)
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
return True
|
||||
|
||||
|
||||
class _S:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _P:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
async def _e2e():
|
||||
hass = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
c = Controller(opts, hass, _S(), _P(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
seen_wrong_way = False
|
||||
for _ in range(12):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
if c.target < -300 and not c.sign_wd.tripped:
|
||||
seen_wrong_way = True
|
||||
await asyncio.sleep(0.25)
|
||||
return c, hass, seen_wrong_way
|
||||
|
||||
|
||||
ctrl, hass, wrong_way = asyncio.run(_e2e())
|
||||
check("the broken loop really did command charge into an import first", wrong_way)
|
||||
check("the watchdog tripped", ctrl.sign_wd.tripped)
|
||||
check("the commanded value is 0 W", ctrl.target == 0.0)
|
||||
check("0 W actually reached the device", 0.0 in hass.writes)
|
||||
check("and it got there through the failsafe claim, not by accident",
|
||||
"failsafe" in ctrl.reason)
|
||||
print(f" status line: {ctrl.reason!r}")
|
||||
check("the status page says so in words",
|
||||
any("SIGN-DISAGREEMENT FAILSAFE" in c["text"] for c in ctrl.checks()))
|
||||
check("the banner leads with it",
|
||||
"FAILSAFE" in ctrl.status_payload()["banner"])
|
||||
check("MQTT reports the failsafe state", ctrl.sign_wd.tripped)
|
||||
check("it stays at 0 W on later cycles too",
|
||||
hass.writes[-1] == 0.0 and hass.writes.count(0.0) >= 1)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
Reference in New Issue
Block a user