Compare commits
25
Commits
0c7e786ed5
...
MAINT-05
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
905b6fd2b3 | ||
|
|
65cddf35f1 | ||
|
|
1aef19e995 | ||
|
|
2d025eebf7 | ||
|
|
ae21b71824 | ||
|
|
18f052a071 | ||
|
|
d5c1577212 | ||
|
|
22c016fadd | ||
|
|
f000547518 | ||
|
|
6b85acb0f1 | ||
|
|
b30797e1f9 | ||
|
|
7ef3d23245 | ||
|
|
b6f41f736c | ||
|
|
753f700539 | ||
|
|
f594543988 | ||
|
|
d48c6b971d | ||
|
|
e941bf7f62 | ||
|
|
e306c74cb8 | ||
|
|
591c35ed01 | ||
|
|
3030f72b9e | ||
|
|
3fe3c7acb0 | ||
|
|
186e13ceca | ||
|
|
df88b323f5 | ||
|
|
38f6680639 | ||
|
|
06f95e0a64 |
+18
-1
@@ -83,7 +83,24 @@ rejected.
|
||||
|
||||
⚠️ **If you are testing the failsafe by hand, note that stopping and starting the
|
||||
add-on will not clear a trip.** That is the point of it; use the *Start / stop
|
||||
control* button twice, or delete `sign_tripped` from `/data/state.json`.
|
||||
control* button twice, or delete the trip from `/data/state.json`.
|
||||
|
||||
⚠️ **DEV-02 renamed that key. There is one `SignWatchdog` per inverter, so the
|
||||
LIVE latch lives under `unit/<inverter>/sign_tripped`** —
|
||||
`unit/inverter-a/sign_tripped` on a single-inverter site. **That is the one to
|
||||
delete if you are clearing a trip by hand**; deleting the flat one alone clears
|
||||
nothing.
|
||||
|
||||
⚠️ **The flat `sign_tripped` is still maintained, though — it is the ROLLBACK
|
||||
VIEW, not a fossil.** It is written alongside the namespaced key on a trip and
|
||||
cleared alongside it when you press *Start / stop control*, so an add-on you
|
||||
**downgrade** past this version still finds the latch it should. It is also read
|
||||
on **every** start, and the one disagreement it can produce is acted on: *the
|
||||
flat key says tripped and no inverter came up latched* means the latch was
|
||||
written by an older add-on while this install was rolled back — or the migration
|
||||
lost it — and the controller **re-arms the latch and shouts in the log** rather
|
||||
than coming up disarmed with a green banner. So if you edit `/data/state.json`
|
||||
by hand, clear **both** spellings or the next start will put the trip back.
|
||||
|
||||
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
|
||||
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
|
||||
|
||||
@@ -2,6 +2,707 @@
|
||||
|
||||
## Unreleased
|
||||
|
||||
**Every pack is recalibrated on its own schedule, and only one moves power at a
|
||||
time (MAINT-05).** §12's monthly cycle drains a pack to empty and refills it to
|
||||
true its coulomb counter. There was exactly one `Maintenance` state machine and
|
||||
one un-namespaced history, so at two packs **only the first was ever
|
||||
recalibrated** and the second's counter drifted forever — and nothing prevented
|
||||
the cycle draining pack A while the loop or arbitrage charged pack B, which is
|
||||
two power-moving phases on one grid connection pulling against each other.
|
||||
|
||||
* **ONE `Maintenance` PER ROSTER ENTRY**, each with its own schedule, phase and
|
||||
history under `unit/<name>/...`. `store.migrate_maint_keys()` moves an
|
||||
existing install's flat history into the first pack's namespace under
|
||||
`migrate_unit_keys()`'s three rules — shared in code, not restated — with the
|
||||
same read-back postcondition, and the flat keys are kept **live** as the
|
||||
rollback view so a downgrade finds a current history rather than one dated
|
||||
migration day.
|
||||
* **ONE MAINTENANCE SLOT PER SITE.** At most one pack may be in a power-moving
|
||||
phase (`drain`, `charge` **and** `hold` — `charge` is in the set because a
|
||||
pack pulled full from the grid beside a pack exporting to empty is 4 kW
|
||||
circulating with the meter at zero). The holder is **derived** from the packs'
|
||||
own stored phases, not persisted, so a restart mid-drain re-derives it. When
|
||||
several packs are due in the same hour the slot goes to the one that has gone
|
||||
**longest without a completed cycle**; roster order breaks a numeric tie and
|
||||
nothing else. Nothing preempts a cycle in flight.
|
||||
* **THE DEFERRED PACK IS NOT STARVED AND IS NOT A FAULT.** A deferral does not
|
||||
stamp `last_start_attempt` (that is the 90 min post-abort cooldown, inside a
|
||||
60 min start hour), and does not move the phase, so neither the 12 h `drain`
|
||||
nor the 36 h `charge` timeout — *"the battery is not following commands"* —
|
||||
can be reached by waiting. It says WAITING, names the pack it waits for, and
|
||||
recalibrates at the next start hour; a test drives the winner's whole cycle
|
||||
and observes it start.
|
||||
* **THE SCHEDULE IS NOT STAGGERED BY CONSTRUCTION.** The interlock defers and
|
||||
the stagger is what comes out of it: one contested month separates two packs
|
||||
by one cycle length and they stay separated. `DECISIONS/MAINT-05-per-pack-maintenance.md`
|
||||
§3 carries the argument.
|
||||
* **`validate.py` rule 6 now grades `maintenance_charge_w` against the WEAKEST
|
||||
cap on the roster**, like rule 5. Its own comment said it would have to move
|
||||
the day `maint_unit` stopped being `inverters[0]`; that day is this card. It
|
||||
refuses configurations that used to start — a 3000 W charge beside a 2000 W
|
||||
pack that is now recalibrated too — which is the `lo > hi` contradiction rule
|
||||
6 exists to refuse, caught when the config is written. Identical at N=1.
|
||||
* **AT A ROSTER OF ONE, NOTHING CHANGES**, and it is asserted rather than
|
||||
assumed: the state file keeps the flat keys and gains none, the migration does
|
||||
not run, the four cycle events are the shipped strings character for
|
||||
character, and the status banner is the bare phase with no pack name.
|
||||
* **THE MIGRATION IS GRADED AGAINST THE ROSTER, NOT AGAINST THE NAME IT WAS
|
||||
HANDED** (fix round). `migrate_maint_keys()` takes the roster rather than a
|
||||
pack count and `_verify_moves()` checks the namespace it wrote against the
|
||||
names the machines actually read. A postcondition that reads back the
|
||||
namespace it was given cannot detect being given the wrong one: handed
|
||||
`inverter.UNIT_A` on a roster of `["garage", "shed"]`, the first version of
|
||||
this card wrote all four keys under `unit/inverter-a/...`, read all four back
|
||||
equal, reported **verified**, and stamped `maint_schema_version` — so both
|
||||
packs came up believing they had never been recalibrated and the next start
|
||||
skipped the migration too. That is now `misdirected`: not `ok`, the marker is
|
||||
**not** written, and the next start re-runs and recovers (rule 1 makes the
|
||||
re-run a no-op). `build_roster()` numbers a nameless roster entry
|
||||
`inverter-1`, so `inverter-a` is not even the fallback for a declared roster.
|
||||
Every two-pack fixture that could see this now names its first pack
|
||||
`garage`; with them all called `inverter-a`, `self.inverters[0].name` and
|
||||
`UNIT_A` were the same string and the swap left all 19 suites green.
|
||||
* **AND THE REFUSAL NOW SURVIVES THE NEXT START** (second fix round). The fix
|
||||
above graded only the keys it had just *written*, so it refused exactly once:
|
||||
measured at Controller level over one persisted store, roster
|
||||
`["garage", "shed"]`, with the call site still wrong on both starts —
|
||||
construction 1 `ok=False misdirected=4 moved=4 kept=0 marker=<absent>`,
|
||||
construction 2 `ok=True misdirected=0 moved=0 kept=4` and the marker
|
||||
**stamped**. On the second start rule 1 finds the wrong keys already there and
|
||||
routes all four to `kept`, so `moved` is empty and the roster loop grades
|
||||
nothing — and start 3 skips the migration forever, *including after the call
|
||||
site is fixed*. Loud-and-recoverable became silent-and-permanent after one
|
||||
restart. `_verify_moves()` now grades `set(moved) | set(kept)`; both lists are
|
||||
built from the same `unit` argument, so grading `kept` grades the same
|
||||
namespace decision. `test_maintenance.py` part **9c** drives two starts with
|
||||
the same wrong unit over one store — the shape nothing in the suite had, since
|
||||
9b measured recovery along the path where the operator has *already* fixed the
|
||||
call site.
|
||||
* **AND THE MARKER GATE IS PINNED ON BOTH GUARDS.** `if rep.ok:` is
|
||||
`not lost and not misdirected`, and the mutation `if rep.ok or rep.kept:`
|
||||
stamped the marker on a migration that **lost a month of history** with all 19
|
||||
suites green. Part **9d** is the fixture that separates the two guards: two
|
||||
keys already namespaced (`kept` non-empty) and two whose write the store
|
||||
drops (`lost` non-empty), `misdirected` empty throughout.
|
||||
* ⚠️ **AND THE SAME MUTATION ONE FUNCTION UP WAS A SURVIVOR, FOUND HERE AND
|
||||
CLOSED.** `migrate_unit_keys()` — SAFETY-02's **latch** migration — gates its
|
||||
own marker on `rep.ok` too, and every check that reached that gate ran on a
|
||||
store where nothing was namespaced yet, so `rep.kept` was empty in all of
|
||||
them. `if rep.ok or rep.kept:` there stamps `schema_version` on a migration
|
||||
that **dropped the latch**: the guard is off, the file still says
|
||||
`sign_tripped: true`, and the next start skips the migration that would have
|
||||
re-armed it. Measured a survivor of all 19 files; now red on
|
||||
`test_inverter.py` part 10, which drops the `sign_tripped` write beside an
|
||||
already-namespaced `sign_reason`. No source change — the shipped gate was
|
||||
right; nothing could see it.
|
||||
* ⚠️ **FOUND, RECORDED, NOT FIXED (SECOND ONE).** `migrate_unit_keys()` —
|
||||
SAFETY-02's latch migration — has the identical hole and it costs a **guard**
|
||||
rather than a history. It runs before `build_roster()` (each `Inverter`
|
||||
restores its latch in its constructor), so it is handed the constant `UNIT_A`
|
||||
and there is no roster to grade against. On a declared roster a pre-DEV-02
|
||||
`sign_tripped: true` lands under `unit/inverter-a/sign_tripped`, which no unit
|
||||
reads — and `_grade_store_migration()`, whose job is to re-arm exactly this,
|
||||
is **defeated by the key the defect wrote**: its "is anything namespaced
|
||||
latched" test is satisfied by the misdirected value itself. Fixing it means
|
||||
naming the migration's target from the config before any `Inverter` exists,
|
||||
which is `inverter.py` and SAFETY-02's semantics, with its own battery.
|
||||
Measured and pinned as a running check (`test_maintenance.py` part 13), whose
|
||||
assertions state the WRONG behaviour on purpose.
|
||||
* ⚠️ **FOUND, RECORDED, NOT FIXED.** A maintenance drain **pins** its pack while
|
||||
the loop's target is a **site** claim, so when the site target is below the
|
||||
pin the only split asks the sibling to charge against the drain and
|
||||
`allocator.plan()` refuses it — the site parks at 0 W and the pack's 12 h
|
||||
timeout would eventually report *"drain stuck"* about a healthy battery.
|
||||
Pre-existing on `release/1.0` at `2d025ee` with the unit names swapped; fixing
|
||||
it means changing what the loop's target means while a unit is pinned, which
|
||||
is loop and allocator territory. Pinned as a running check
|
||||
(`test_maintenance.py` part 12) so it cannot be forgotten.
|
||||
|
||||
**At two inverters the sign watchdog stops comparing one unit against the whole
|
||||
site meter, and becomes two checks instead of one (SAFETY-30).**
|
||||
`disagrees(commanded_w, grid_w, ...)` compared the command **this controller put
|
||||
on ONE actuator** against **what the whole site** is exchanging with the network.
|
||||
At a roster of one those are two views of the same thing - §6.2's identity - and
|
||||
that is what makes the check sound and what earned it the best record in the
|
||||
safety table. At two they are not, and it fails **in both directions**: inverter
|
||||
A commanded −1500 W while the meter reads +1500 W is evidence of nothing when
|
||||
inverter B is discharging 3000 W exactly as told, and - worse - a unit genuinely
|
||||
driving the wrong way is **MASKED** by a sibling that covers for it, because the
|
||||
site figure nets. No threshold recovers that; the summation destroys the
|
||||
evidence.
|
||||
|
||||
* **PER UNIT: each inverter's own share against its OWN measured power**
|
||||
(`Inverter.batt`, holding register 0x0518, per-instance since DEV-02).
|
||||
Conclusion: *the actuator I am driving is not doing what I told it* - evidence
|
||||
about one device, so the remedy stays the per-unit `failsafe` SET that
|
||||
`arbiter.CLAIM_SCOPE` has classified `SCOPE_UNIT` since it was written. That
|
||||
entry read *"the evidence is site-wide and the remedy is not"*; after this card
|
||||
the first half is simply true. Verified by making one unit reverse while its
|
||||
sibling covers it at the meter: the shipped comparison is false on **0 of 14**
|
||||
cycles while the new one convicts that unit on every one, and only that unit is
|
||||
parked.
|
||||
* **SITE: the SUM of the standing commands against the meter**, as a new
|
||||
`sign_site` SET at `P_SAFETY` on the site actuator, latched under flat
|
||||
`site_sign_tripped` / `site_sign_reason`. This is the fault the 2026-08-20
|
||||
capture contains and **no per-unit check can see it**, because every inverter
|
||||
is faithfully executing its share - what is wrong is the number they were
|
||||
given. It stops every inverter and the banner names the site rather than an
|
||||
inverter, so nobody is sent to swap the wrong box.
|
||||
* **⚠️ Different questions from SAFETY-31, and the PR and the decision record
|
||||
both say which.** `circulation.py` compares the units **against each other**
|
||||
and catches two inverters pushing *through* each other, which nets to zero at
|
||||
the meter and which no single command is evidence about. This compares each
|
||||
unit against **its own command**. They overlap in exactly one scenario - a unit
|
||||
reversing while its sibling pulls the other way - and `test_watchdog.py`
|
||||
asserts on that fixture that both fire and what each concludes. It is also not
|
||||
the saturation freeze: that is a magnitude test (`|command − measured| >
|
||||
500 W`) that shapes the loop and fires on a merely saturated unit; this is a
|
||||
direction test that latches and parks one.
|
||||
* **⚠️ All four thresholds RE-DERIVED at two inverters - one carried with a
|
||||
justification, one refused.** 1890 closed-loop runs in which nothing is faulty,
|
||||
over the whole range `config.yaml` accepts for `gain` and `slew_w`, across load
|
||||
reversals with write staggers and flapping loads, **run at both rosters so the
|
||||
N=1 arm is the control.** `unit_sign_disagree_w: 250` is `saturation_w / 2`, so
|
||||
the smallest divergence this can see is exactly the gap at which the control
|
||||
law itself already says the inverter is not following; `unit_sign_disagree_s:
|
||||
85` is 8.5× the worst legitimate opposition those runs produce (10.0 s), 2.8×
|
||||
the firmware's own 30 s link veto and under half the site hold.
|
||||
`site_sign_disagree_w: 300` is **carried** - its argument is the meter's noise
|
||||
floor and the deadband, and the roster touches neither. **`site_sign_disagree_s`
|
||||
is NOT: 180 s would have shipped a false trip.** The worst legitimate crossing
|
||||
at 300 W is 110 s with one inverter and **215 s with two**, because the command
|
||||
must travel a rail that is the roster sum at a `slew_w` that is not - reachable
|
||||
at `gain: 0.05`, `slew_w: 50` and a 2.2 kW load reversal, all schema-legal.
|
||||
325 s is 1.51× that, inside the 900 s billing quarter and inside every episode
|
||||
of the fault day. See `DECISIONS/SAFETY-30-per-unit-sign.md`.
|
||||
* **⚠️ At ONE inverter this changes nothing, and "nothing" is asserted rather
|
||||
than assumed.** The two questions are the same sentence at a roster of one, so
|
||||
only the detector that shipped is armed: same comparison against the meter,
|
||||
same 300 W / 180 s, same reason string byte for byte, same namespaced latch and
|
||||
flat rollback mirror, same `failsafe` claim, same banner, same single status
|
||||
row - and the site detector's window is never so much as opened.
|
||||
`unit_sign_disagree_*` and `site_sign_disagree_*` do nothing on a
|
||||
one-inverter install.
|
||||
* **The threshold WIRING is pinned, not just the threshold values.** Review
|
||||
found that `arm(self.sign_cfg if one else self.unit_sign_cfg, ...)` could be
|
||||
collapsed to `arm(self.sign_cfg, ...)` — arming every unit with the
|
||||
meter-facing pair instead of the re-derived per-unit one — with all 19 test
|
||||
files still green, because nothing at a roster of two read `sign_wd.cfg` and
|
||||
the trips in the fixture happen under either pair. `test_watchdog.py` part 3
|
||||
now asserts the pair and the instrument on **every** detector against
|
||||
literals, and the fixture's three threshold pairs were made pairwise distinct
|
||||
in both coordinates so that a hold delivered from the wrong pair cannot
|
||||
compare equal to the right one. M14–M16 in
|
||||
`DECISIONS/SAFETY-30-per-unit-sign.md` §5.
|
||||
* **Known and recorded rather than fixed:** the site comparison is defeated by a
|
||||
square-wave load whose half period is about one control cycle, which holds it
|
||||
opposed for ~1000 s at *both* rosters. The N=1 control arm is what says this is
|
||||
a property of comparing a lagged command against a meter and has nothing to do
|
||||
with the second inverter, so it is not acted on here - it wants an alternation
|
||||
test, not a number, and a card of its own.
|
||||
|
||||
**An operator can declare a second inverter, and the shape was measured against
|
||||
the Supervisor rather than assumed (CFG-04).** DEV-02 made rating, SoC,
|
||||
watchdogs, heartbeat and store keys per-instance, so the code no longer assumed
|
||||
one inverter — but the options schema still described exactly one, and
|
||||
`build_roster()` returned a list of length one and said so in its own docstring.
|
||||
The roster could only ever be a roster of one. **Version bumped to 0.6.0,
|
||||
because the Supervisor keys the built image by `version:` and a schema change
|
||||
without a bump is a schema nobody reads.**
|
||||
|
||||
* **`inverters:` — a list of objects, defaulting to `[]`.** Empty is not
|
||||
"unconfigured", it is **the single-inverter configuration**: the flat
|
||||
`setpoint_entity` / `soc_entity` / `batt_entity` / `batt_invert` / `max_w`
|
||||
keys describe the one unit exactly as they always did. An install that
|
||||
upgrades reads identically — same entities, same rating, same behaviour, no
|
||||
operator action, and the whole existing check suite runs against it unchanged.
|
||||
* **⚠️ The shape was ESTABLISHED, not assumed, and the empty default is the
|
||||
load-bearing part.** There was no list-of-objects anywhere in `config.yaml`
|
||||
and `static_profile` carries its structure as a JSON string in a `str?`
|
||||
precisely because a nested schema was doubted. So Supervisor **2026.08.0**'s
|
||||
own `AppOptions` validator — the version this site runs — was run against this
|
||||
repository's `config.yaml` out of the release image
|
||||
(`tools/supervisor_shape_probe.py`, committed; the transcript and the
|
||||
reasoning are in `DECISIONS/CFG-04-inverter-roster.md`). It accepts the list,
|
||||
enforces per-entry types, refuses a missing `name` / `setpoint_entity` /
|
||||
`max_w` **by name**, and renders the option in the UI as a repeatable section.
|
||||
And the shipped `options:` block validates as it stands while the **same
|
||||
block with only `inverters` removed** is answered with **`Missing option
|
||||
'inverters' in root`** — one key varied, so the refusal is about that key —
|
||||
which is every options blob written before this version, since the key did not
|
||||
exist when they were written. `App.options` is
|
||||
the shipped `options:` block deep-merged with the operator's stored one, so
|
||||
`inverters: []` in `config.yaml` is the difference between an upgrade nobody
|
||||
notices and an add-on that cannot start with a schema pinned to the version
|
||||
that would fix it. That is `docs/deploy-rollback.md` §4's trap in the forward
|
||||
direction, found before it was sprung rather than after.
|
||||
* **Nothing is inherited by an entry that omits a key, and that is DEV-02
|
||||
restated as a config rule.** `name`, `setpoint_entity` and `max_w` are
|
||||
required of every entry; a missing `soc_entity` means *this unit has no SoC
|
||||
sensor*, never *use the other one's*. A three-line fallback to the flat keys
|
||||
would have rebuilt the sibling-grading defect DEV-02 spent a card removing, in
|
||||
YAML. Defaults still live in exactly one place (CFG-03): there is no
|
||||
per-entry default anywhere, because there is no optional per-entry number.
|
||||
* **SAFETY-28's `actuator_writers()` refuses two inverters naming one
|
||||
`setpoint_entity` — the first configuration in this add-on's life in which
|
||||
that was expressible.** The census was already structural and case-folding, so
|
||||
it needed no change; what it needed was a config that could express the
|
||||
hazard, and now there is one. Its sibling refusal is new: a flat
|
||||
`setpoint_entity` left set beside a declared roster names an actuator nothing
|
||||
will write, and is refused rather than ignored.
|
||||
* **⚠️ Two PERMISSIVE READERS in shipped code, found and fixed.** Both failed in
|
||||
the direction that hides a defect. (1) `validate.py` rules 5 and 6 compared
|
||||
`sign_disagree_w` and `maintenance_charge_w` against the **flat** `max_w`; at
|
||||
a roster of two 2000 W units with `max_w: 5000` left over from a
|
||||
single-inverter install, `sign_disagree_w: 3000` passed rule 5 while
|
||||
SAFETY-02's watchdog could fire on **neither** unit — rule 5's own failure
|
||||
mode, reached through rule 5. They now read the roster's caps
|
||||
(`unit_caps()`), which at one inverter is `[max_w]` exactly. (2)
|
||||
`run_control()` re-ran the device-rating check behind `if
|
||||
self.o.get("setpoint_entity")` — the flat key, which a roster config leaves
|
||||
blank — so on a two-inverter site **no** inverter's `max_w` was ever graded
|
||||
against the device it is written to. `validate_unit_ranges()` grades each unit
|
||||
against its own ESPHome and runs unconditionally.
|
||||
* **⚠️ Three config.yaml READERS IN THE CHECKS took the first match on a
|
||||
stripped line, and one of them was already known.** `test_peakguard.py`'s
|
||||
`read_option()` and `_schema_bound()` and `test_inverter.py`'s
|
||||
`read_schema_max()` threw indentation away, so the nested per-inverter
|
||||
`max_w:` began outranking the flat one — **silently, and correctly**, because
|
||||
the two bounds are the same `int(100,5000)` today. A reader that is right by
|
||||
coincidence is the failure mode this project is named after. All three are
|
||||
anchored at exactly two spaces now, the halves of the file disambiguate
|
||||
`peak_cap_w` instead of first-match, and an ambiguous key raises rather than
|
||||
picking one. `test_tariff.py`'s copy of the idiom went with them.
|
||||
* **The audit is a check, not a promise.** `test_inverter.py` part 11 finds
|
||||
every `config.yaml`-reading function in the suite — transitively, so a reader
|
||||
that never names the file because it delegates is still found — **executes**
|
||||
each one against a synthetic two-inverter `config.yaml` whose per-inverter
|
||||
numbers differ from its flat ones, and fails if any returns the per-inverter
|
||||
value. The table is not maintained by hand: the signature decides, so the
|
||||
eleventh reader is named on its first run. `config.yaml` declares `inverters:`
|
||||
**before** `max_w:` on purpose, and part 11 asserts that ordering, so the trap
|
||||
stays baited rather than sorted out by an ordering nobody would maintain.
|
||||
* **Ten mutations run and observed red** (`tools/mutation_run.sh`), listed in
|
||||
`test_inverter.py` part 12 with the check that bites each. **Two survived the
|
||||
first run and the checks were changed, not the table:** the inheritance check
|
||||
had blank flat keys, so "inherited" and "not inherited" were the same empty
|
||||
string; and the `run_control()` check asserted a **source line** was present,
|
||||
which re-indenting it does not remove. The second is now driven through the
|
||||
shipped `run_control()` under a deadline, because that mutation's real symptom
|
||||
is a hang rather than a red.
|
||||
|
||||
**Circulating power - two inverters pushing against each other - becomes a
|
||||
measured quantity, a bounded one, and an alarm that survives a restart
|
||||
(SAFETY-31).** Inverter A charging at 3 kW while inverter B discharges at 3 kW
|
||||
nets ~0 W at P1: the site reads idle while the packs are cycled through two
|
||||
round-trip conversion losses continuously. **Every guard in this add-on is a
|
||||
consumer of that net figure**, so none of them can see it - SAFETY-02's sign
|
||||
watchdog gates on `abs(grid_w) > 300` and the gate never opens, and both the
|
||||
peak guard and the capacity tariff bill grid exchange.
|
||||
|
||||
* **A site sensor, `Σ|Bᵢ| − |ΣBᵢ|`.** Zero when the units pull the same way,
|
||||
`2 × min(|B_a|,|B_b|)` when they oppose. Published as
|
||||
`sensor.goodwe_circulating_power` beside the grid figure, because *"grid 0 W,
|
||||
circulating 6000 W"* is the whole phenomenon in two dashboard rows and no
|
||||
arithmetic on the grid figure alone can produce the second one.
|
||||
* **⚠️ Derived from MEASURED per-inverter power, never from the allocation
|
||||
record, and that is the whole card.** ALLOC-01's sign-coherence gate
|
||||
(`REFUSE_SIGN`, its AC 7) already refuses any allocation whose shares carry
|
||||
two signs, so a record-derived sensor reads zero **by construction** and could
|
||||
only ever confirm that the allocator agrees with itself. What this detects is
|
||||
circulation **nobody commanded**: a unit ignoring or lagging its share, a
|
||||
stale share still being executed, a maintenance or SAFETY-25 pin holding one
|
||||
unit while the loop drives the other, or HW-01's power stage running its last
|
||||
instruction for **6 h 25 m** with the comms dead and the allocation record
|
||||
impeccable throughout. Verified by making one unit ignore its share on the
|
||||
TEST-19 rig: the record stays `ok` with both shares at −1250 W - a
|
||||
record-derived sensor reads **0 W** - while the shipped sensor reads
|
||||
**2000 W**. `Inverter.batt` became per-instance in DEV-02; before that this
|
||||
sensor could not have been written.
|
||||
* **The trip stops the site, and the decision record says why that is an action
|
||||
rather than theatre.** Sustained opposition files `Claim.set("circulation",
|
||||
P_SAFETY, 0.0)` on the **site** actuator - every inverter to 0 W, latched.
|
||||
HW-01 established that a wedged inverter cannot be commanded at all, so the
|
||||
remedy is not aimed at it: a circulating loop needs **two** participants and
|
||||
**one of them is this controller**, faithfully driving the listening sibling
|
||||
into the one that stopped listening. Stopping halves the loop, and - the more
|
||||
important half - **makes the residue visible at the meter**, where every
|
||||
existing guard can finally see it. What it cannot do is stop the wedged unit;
|
||||
the notification says so, and names the isolator as the last actuator.
|
||||
* **The threshold and the window were measured, not chosen (AC 3).** 924
|
||||
closed-loop runs on the TEST-19 two-master rig in which *nothing* is faulty,
|
||||
swept over the whole range the schema accepts for `gain` and `slew_w`. Worst
|
||||
**continuous** legitimate opposition by threshold: **505.0 s at 100 W, 40.0 s
|
||||
at 250 W, 10.0 s at 300 W, 5.0 s at 400 W and above**. The knee is 400 W and
|
||||
it is the schema floor. `circulation_w: 700` is 1.75× it, the headroom bought
|
||||
for inverter B's ramp and lag being **placeholders until SPIKE-04 measures
|
||||
them**. `circulation_hold_s: 75` clears three bounds - 15× the worst
|
||||
legitimate episode (5.0 s), 2.5× the firmware's own `LINK_STALE_S` veto, and
|
||||
12× inside the 900 s capacity-tariff quarter. **A momentary opposition while
|
||||
one inverter slews through zero is legitimate** - the serialised write path
|
||||
lands B's number up to a control cycle after A's - and the guard does not fire
|
||||
on it, in any of the 924 runs.
|
||||
* **The alarm survives a Home Assistant restart (SAFETY-34).**
|
||||
`persistent_notification` is in memory, which is exactly how the 2026-09-02
|
||||
outage went unseen for 6 h 25 m with the detector correct throughout. The
|
||||
latch is persisted to `/data` as flat, site-level keys - flat because the
|
||||
quantity is defined over the roster and is identically zero for any one unit,
|
||||
so there is no inverter to attribute it to - and the notification is
|
||||
**re-raised on the first cycle after every start**, through the same code path
|
||||
as a fresh trip.
|
||||
* **At one inverter the sensor is identically zero and nothing changes (AC 5).**
|
||||
`|B| − |B| == 0` for every reading, including one nobody took; no claim is
|
||||
ever filed, the arbitration is byte-identical, and the status page says *n/a*
|
||||
rather than claiming to watch something that cannot happen.
|
||||
* **Verified by breaking it.** 18 mutations against the sensor, the window, the
|
||||
latch, the claim, the store, the alarm, the routing table and both config
|
||||
copies - **all red**, each on a named check; one equivalent mutant argued
|
||||
rather than claimed; and one genuine **survivor found and closed** (`publish()`
|
||||
turning an unknown into a published `0 W`). `arbiter.CLAIM_SCOPE` gains its
|
||||
ninth source and `test_peakguard.py`'s 10f/10g tripwires were updated
|
||||
deliberately, as their own comments require. Full ledger in
|
||||
`DECISIONS/SAFETY-31-circulating-power.md`.
|
||||
|
||||
**Every per-device value stops being a Controller scalar: rating, SoC, battery
|
||||
power, watchdogs, heartbeat, write bookkeeping and store keys are now
|
||||
per-instance (DEV-02).** `app/inverter.py` introduces an `Inverter` object that
|
||||
owns its entities, its rating, its device range, its `SignWatchdog`, its
|
||||
`last_write` and its `last_beat`, under **store keys namespaced by unit name**.
|
||||
The Controller holds a list of them and keeps only what is genuinely site-level:
|
||||
the P1 reading, the site integrator, and the tariff quarter.
|
||||
|
||||
* **What the scalars were silently asserting.** One `dev_min`/`dev_max` pair was
|
||||
read from one `setpoint_entity`, so a second inverter's rating was **never
|
||||
read at all** and its clamp, its freeze rail and the peak guard's
|
||||
`achievable_w` were the first one's numbers. One `soc` fed the maintenance
|
||||
FSM, SAFETY-24's pack floor and arbitrage's bounds. One `SignWatchdog` - whose
|
||||
own docstring says *"one instance per actuator"* - latched under **flat** store
|
||||
keys, so a trip caused by B latched A across restarts and one operator press
|
||||
cleared both. One `last_beat` and one serialised `hass.call()` meant a hung
|
||||
write to A ate B's 30 s layer-1 budget.
|
||||
* **`actual_w` became SITE level while the readings became per-instance, and
|
||||
those are opposite directions on purpose.** `compute()`'s anti-windup test is
|
||||
`abs(prev_w - actual_w) > saturation_w` with `prev_w` the **site** target, so
|
||||
feeding it one inverter's power compares a site number against a unit number,
|
||||
trips the saturation freeze permanently and leaves a standing grid error.
|
||||
Measured on `admin/goodwe`'s two-master rig, 2 kW load: with one unit's power
|
||||
the aggregate trace at the meter is split-dependent by **510 W at `gain: 0.2`,
|
||||
250 W at 0.4 and 50 W at 0.6**; with the site sum **every split is
|
||||
bit-identical at every gain the schema accepts**. That was ALLOC-01's
|
||||
disclosed finding, graded in `test_alloc.py` part 8 and now closed there.
|
||||
* **The store migration is graded, not merely performed.** `sign_tripped` /
|
||||
`sign_reason` move to `unit/<name>/...` once, verified by **reading back**
|
||||
what was written, and the version marker is only set when nothing that carried
|
||||
state was lost. The flat keys are left in the file so a rollback still finds
|
||||
its latch. And `Controller.__init__` compares the pre-migration flat latch
|
||||
against what unit A actually came up with: if the latch did not survive it is
|
||||
**re-armed from the legacy value and shouted about**, because a latch that
|
||||
silently fails to migrate is a disarmed safety guard on an install whose state
|
||||
file says it is protected.
|
||||
* **Heartbeats are independent, and the budget is derived.** Each inverter owns
|
||||
its own deadline, the refreshes are dispatched **concurrently**, and each write
|
||||
is bounded by `WRITE_BUDGET_S` (4 s). The inequality that fixes that number is
|
||||
graded rather than asserted: `4 + heartbeat_s`'s schema maximum of `25 < 30`,
|
||||
layer 1's `FIRMWARE_INGEST_VETO_S`. Verified by injecting a transport that
|
||||
accepts and never answers: B's write reaches the wire while A is still
|
||||
hanging, and the serialised shape it replaces is run beside it.
|
||||
* **`live_units()` answers honestly.** A unit whose every write has been rejected
|
||||
for a whole layer-1 window is not commandable; the allocator drops it, the
|
||||
survivors carry its share, the action log names it, and the dropped unit is
|
||||
commanded **0 W** rather than left standing on its last share. A roster entry
|
||||
with **no** `setpoint_entity` is deliberately *not* handled there - that is a
|
||||
configuration that cannot be delivered, and it reaches main.py's refusal
|
||||
branch, which commands 0 W and names the inverter.
|
||||
* **At N=1 nothing moves.** The removed scalars survive as read/write properties
|
||||
of the sole inverter, so every existing replay in this repository runs
|
||||
unmodified - and they **refuse at N>=2** rather than answering for the first
|
||||
inverter, which is the tripwire on a consumer that was never made
|
||||
per-instance. `test_inverter.py` is the new file (77 checks); `test_alloc.py`
|
||||
part 8, `test_peakguard.py` 10g/10h, `test_watchdog.py` and `test_clamp.py`
|
||||
were re-aimed rather than relaxed.
|
||||
* **Inverter B still does not exist.** `build_roster()` returns exactly one
|
||||
inverter, from the flat options, and is the one function CFG-04 changes. Every
|
||||
two-unit figure above is architecture, not a measurement of a second device;
|
||||
the second rating in the checks is marked as a hypothesis.
|
||||
|
||||
**The write path is gated on the allocation record, not on how many config keys
|
||||
exist (SAFETY-28).** specs §1.5 makes *"any configuration in which two writers
|
||||
can reach one actuator"* a non-goal. Until now that non-goal was enforced by
|
||||
`len(validate.ACTUATOR_WRITE_KEYS) == 1` - there is exactly one option key, so a
|
||||
second writer is not expressible in the schema. True, and a statement about **the
|
||||
shape of the options schema rather than about the writes**: add a per-inverter
|
||||
config (CFG-04) and there are two real writers with that length still 1, so the
|
||||
check stays green while the property it protects is gone. `sim/inject.py`'s
|
||||
`two_writers` scenario asserted on the same tuple and went green with it.
|
||||
|
||||
* **The enforcement moved onto the writes.** `write_setpoint()` now refuses any
|
||||
value that is not in **this tick's** allocation record from ALLOC-01:
|
||||
`Controller.write_refusal()` asks `Allocation.authorises()` whether the single
|
||||
allocator placed exactly this number, for this unit, on this tick. A second
|
||||
writer with arithmetic of its own cannot satisfy that - its number appears in
|
||||
no record - so it has to file a `Claim` and go through `resolve()`, which is
|
||||
the one allocator. "Exactly one allocator per shared resource" stops being a
|
||||
convention and becomes something the write path checks.
|
||||
* **A refusal is a refusal, not a log line.** The unauthorised value is replaced
|
||||
with **0 W and written**. Returning instead would leave the inverter latched
|
||||
on its last command with the ESP32 heartbeat still being fed - holding an
|
||||
unauthorised setpoint quietly, which is the outcome the gate exists to prevent.
|
||||
* **A stale record cannot be replayed.** Every record now carries the `tick` it
|
||||
was made for, handed *in* by the caller so `allocator.plan()` stays the pure
|
||||
function `test_alloc.py` part 10 grades. The counter advances **once per
|
||||
resolution, not once per loop iteration**: a new allocation makes the previous
|
||||
record stale immediately, while the "inputs missing, not yet stale" hold -
|
||||
which returns before the allocator runs, so one dropped meter reading does not
|
||||
zero the inverter - leaves the standing authorisation intact for the heartbeat.
|
||||
An **unstamped** record authorises nothing; "I cannot say when I was made"
|
||||
fails closed.
|
||||
* **⚠️ 0 W IS AUTHORISED UNCONDITIONALLY, SO THE FAILSAFE CANNOT DEADLOCK BEHIND
|
||||
THE GATE.** `write_setpoint()` is also how layer 2 commands zero, and every
|
||||
path that does so - `cycle()`'s two refusal branches, `shutdown()`, the
|
||||
operator's stop button - runs while the allocator has *refused*. A gate that
|
||||
asked the allocator's permission to command zero would block the safety write
|
||||
behind the very component whose failure the safety write answers. The
|
||||
exemption is on the **value**, not on a `failsafe=True` flag a caller asserts,
|
||||
and the argument is that the hazard §1.5 names is N-times loop gain from
|
||||
*broadcast*: at `S = 0` the broadcast and the correct allocation coincide -
|
||||
`a_i = 1` for every unit gives every unit 0 W, which is exactly its share - so
|
||||
there is no over-command to make at zero. Driven end to end through the real
|
||||
refusal branch in `test_clamp.py` part 7c.
|
||||
* **`unmet_w` is still not `ok`.** The gate reads `ok` and the unit's share and
|
||||
never `unmet_w`, because an allocation that could not place every watt is
|
||||
still safe to write; fusing them would let one saturated inverter park the
|
||||
whole site. Graded on a record with 3800 W unmet.
|
||||
* **`ACTUATOR_WRITE_KEYS` is replaced by `actuator_writers()`**, which counts
|
||||
**writers per actuator** rather than option keys, and finds them by walking
|
||||
the options tree rather than by looking for a container name CFG-04 has not
|
||||
chosen yet. Two inverters with two entities are accepted - that is what the
|
||||
per-inverter roster is *for*; two declarations aimed at one entity are refused,
|
||||
naming the actuator and every writer pointed at it. The tuple survives only as
|
||||
the enumeration a census needs, and nothing asserts on its length any more.
|
||||
* **What neither check observes, said out loud.** The census sees *configured*
|
||||
writers, so a second write path added in **code** is invisible to it - exactly
|
||||
as it was invisible to the tuple. That half is closed at runtime by the record
|
||||
gate, which does not care what the options look like or who called the method.
|
||||
* Verified by breaking it: seven mutations on a purged tree via
|
||||
`tools/mutation_run.sh` - removing the gate, making the zero exit an amnesty,
|
||||
dropping the tick comparison, deleting the census refusal, fusing `unmet_w`
|
||||
into `ok`, freezing the tick on the live path, and moving the gate below the
|
||||
clamp - each turn `test_clamp.py` or `test_validate.py` red.
|
||||
|
||||
**The site grid target is now ALLOCATED across N inverters, sum-invariant, and
|
||||
never broadcast (ALLOC-01).** `ARB-03` left `allocate()` as a documented seam
|
||||
that passed through at N<=1 and DECLINED at N>=2; this fills it. The new
|
||||
`app/allocator.py` turns one site target `S` into per-inverter shares with one
|
||||
invariant - **`sum(shares) + unmet_w == S`, in integer arithmetic** - and each
|
||||
inverter is then told a function of **its own share**, never of the shared
|
||||
measurement.
|
||||
|
||||
* **Why a broadcast is a fault and not merely an inefficiency.** The control
|
||||
primitive is meter emulation: the master reports a *fabricated grid reading*
|
||||
and the inverter regulates itself to it, so one number means "the battery
|
||||
moves X W" here and "the grid is at X W" there - an identity that holds only
|
||||
at N=1. Hand both inverters the same target and each supplies it in full, so
|
||||
the loop gain at the meter becomes N times the per-unit gain. Measured on
|
||||
`admin/goodwe`'s two-master rig (TEST-19): **-400 W export overshoot at
|
||||
`gain: 0.6`, and at `gain: 1.0` - which `config.yaml` accepts as its
|
||||
documented maximum - a permanent 4000 W peak-to-peak limit cycle with not one
|
||||
guard firing.** The sign watchdog is evaluated on every cycle and never trips,
|
||||
because the disagreement flips on alternate ticks and never holds its 180 s
|
||||
window.
|
||||
* **The stability property is structural, not tuned.** With `sum(a_i) = 1` the
|
||||
gain at the meter is `sum(a_i * g_i)`, a **convex combination** of the
|
||||
per-unit gains, so it lies in `[min g_i, max g_i]` **for any split**. That is
|
||||
what makes the weights a comfort choice (SoC, thermals, wear) rather than a
|
||||
tuning parameter, and it means a bad split cannot destabilise the site.
|
||||
Graded directly in `test_alloc.py` part 9, and measured end-to-end: a 90/10,
|
||||
a 50/50 and a 100/0 split produce a **bit-identical aggregate trace at the
|
||||
meter**, and a gain sweep to 1.0 at every split shows a flat tail at all 84
|
||||
combinations.
|
||||
* **Rounding is a safety property here.** The register is 1 W, and a per-unit
|
||||
`round()` biases the sum - measured at **-125 W over 50 000 ticks at three
|
||||
inverters**. At 1-2 Hz that is a permanent standing error the site integrator
|
||||
chases and never reaches. So the target is rounded **once**, at the top, and
|
||||
the fractional parts are settled by **largest remainder** with a deterministic
|
||||
tie-break; every sum below that line is integer arithmetic and cannot drift.
|
||||
Verified over 250 000 randomised ticks: **0 sum failures, 0 envelope escapes**,
|
||||
and the one rounding that is left - the single site-level `quantisation_w`,
|
||||
never distributed into a per-unit bias - totals **-39.8 W over 137 964
|
||||
allocations, i.e. -0.0003 W per tick.**
|
||||
* **Each share is clipped to that unit's interval, and THE TWO ENDS OF THE
|
||||
INTERVAL ARE APPLIED INDEPENDENTLY.** `UnitBounds()` defaults to
|
||||
`(-inf, +inf)`, so a one-sided envelope is the ordinary case at N>=2 rather
|
||||
than an edge. The first cut of this work folded both ends into one
|
||||
`min(max(v, lo), hi)` and substituted `v` itself for a missing bound, which
|
||||
reads as "an absent bound cannot bind" but is not what it does: with
|
||||
`hi == inf` the expression collapses to `min(max(v, lo), v) == v`, so **a
|
||||
missing ceiling silently discarded the floor.** `_clamp_int(0, 2142, inf)`
|
||||
returned 0. The worked failure it caused: a unit with a 2000 W floor and no
|
||||
ceiling, beside a symmetric unit, against a +1000 W site target, was allocated
|
||||
**+500 W - a quarter of its own floor** - and the sign-coherence refusal that
|
||||
the same case with a finite ceiling correctly raises was **suppressed** with
|
||||
it. Fixed by clamping each end on its own, and `UnitPlan.explain()` can no
|
||||
longer print a share as being inside an interval that excludes it: that line
|
||||
now reads `OUTSIDE ... - ENVELOPE VIOLATED, DO NOT WRITE`.
|
||||
* **The envelope is read per tick, never cached.** `plan()` is a pure function
|
||||
of that tick's intervals and holds no state, because a unit's range moves for
|
||||
reasons unrelated to the allocator - a stale link, a pack at its floor, a
|
||||
device rating that failed to read.
|
||||
* **A dead link is announced, not absorbed.** A unit whose master is stale is
|
||||
dropped from the envelope set; the survivors carry its share, and the
|
||||
allocation record names the unit and the reason so `main.py` logs it. A site
|
||||
running at half its inverters and reporting nothing reads as healthy on every
|
||||
dashboard.
|
||||
* **Opposite directions are refused, not averaged.** One pack discharging while
|
||||
another charges nets to exactly the right number at the meter, so no existing
|
||||
guard can see it. A sign-coherence gate makes it inexpressible.
|
||||
* **`scope_violations()` is now consumed, and it is consumed as a refusal.**
|
||||
ARB-03 left it logging without changing the resolution. A mis-routed claim
|
||||
means the number about to be divided may itself be wrong, and dividing a
|
||||
number that may be wrong is worse than not dividing it - the same answer
|
||||
clause 3 already gives a contradiction. It is *not* promoted into an envelope:
|
||||
a unit-scoped claim that landed on the site names no unit, so promoting it
|
||||
would mean guessing one.
|
||||
* **At N<=1 it is a pass-through, byte-identical.** The share is the site
|
||||
target, as a float, unrounded and unclamped. Every one of the existing suites
|
||||
replays unedited and green.
|
||||
* **`main.py` still refuses to act at N>=2, for a new and narrower reason.**
|
||||
There is one `setpoint_entity`, so this controller can command one inverter; a
|
||||
valid two-way split names an inverter it has no writer for, and commanding a
|
||||
partial site is a worse instruction than commanding nothing. The old
|
||||
"no allocator" refusal and its test (`test_peakguard.py` part 10h) were
|
||||
**re-aimed, not deleted** - `allocated=False` is now reachable on a mis-routed
|
||||
claim, an empty envelope set, or sign incoherence, and all three are graded on
|
||||
real cycles.
|
||||
* **And the replay that missed it was widened, so the fix is graded rather than
|
||||
merely applied.** The 250 000-tick replay drew every envelope as
|
||||
`B(-uniform(0, rating), uniform(0, rating))` - **finite on both ends and
|
||||
containing zero, every time** - while the check it fed claimed "no share ever
|
||||
leaves the envelope it was clamped into". The data could only exercise a
|
||||
symmetric closed interval around zero, so it reported 0 escapes against a live
|
||||
defect. The generator now draws from **every shape `UnitBounds` can express**:
|
||||
half-open above, half-open below, intervals that exclude zero, and bare
|
||||
`UnitBounds()`. Measured A/B against the defective clamp on the same seed and
|
||||
the same 250 000 ticks: **the old generator sees 0 escapes, the new one sees
|
||||
39 991.** Reverting the clamp fix under the widened generator takes
|
||||
`test_alloc.py` red on four checks; re-applying it takes it green. The
|
||||
collapse is now a row in part 12's mutation table.
|
||||
* **Known and not closed here:** at a roster of two the loop's `actual_w` is one
|
||||
inverter's power used as a site measurement, because the add-on binds a single
|
||||
`inverter_power` sensor. That is the *sensing* half of the same N=1 identity
|
||||
this card removes from the *commanding* half, and it makes the aggregate trace
|
||||
split-dependent below `gain: 1.0`. Measured, with the counterfactual, in
|
||||
`test_alloc.py` part 8 and `tools/alloc_sim.py --splits`. It belongs to
|
||||
`DEV-02`.
|
||||
|
||||
**`Claim` carries the `actuator` specs.md always said it did, and `resolve()`
|
||||
is three-stage (ARB-03).** `specs.md` §6.1 declares `actuator: str` as the first
|
||||
field of `Claim`; the shipped `app/arbiter.py` had no such field, so every claim
|
||||
was implicitly about "the one and only actuator", `resolve()` returned one
|
||||
scalar, and `main.py` assigned it to one `self.target`. **There was no seam an
|
||||
allocator could occupy** - and `ARCH-01` decided the site grid target is
|
||||
ALLOCATED across several inverters and never broadcast. This is a regression fix
|
||||
against the written design, and it creates that seam. **At N=1 it is a pure
|
||||
refactor: every one of the 17 suites replays unedited and green, on the same
|
||||
numbers.**
|
||||
|
||||
* **The split, verified at each construction site rather than assumed.** Four
|
||||
sources are about the **grid connection** and are SITE claims - `loop`
|
||||
(regulates `grid_w`, the P1 measurement), `peak` (the quarter-hour average
|
||||
offtake the capacity tariff bills), `arbitrage` (buys and sells at the grid
|
||||
against a day-ahead price) and `safety` (`stopped` is the site's switch,
|
||||
`inputs missing` is the site's own meter). Four are about **a pack, a device
|
||||
or one write** and are PER-INVERTER - `device` (one inverter's own reported
|
||||
rating), `supervised` (`max_w` caps what may be WRITTEN to one setpoint
|
||||
entity), `failsafe` (**site-wide evidence, per-unit remedy**: SAFETY-02 grades
|
||||
the command THIS controller put on THIS actuator, and at N>=2 that evidence
|
||||
cannot be pinned on a sibling nobody here commands) and `maintenance` (§12's
|
||||
recalibration is a pack procedure). The reasoning is recorded **at the line**,
|
||||
in `arbiter.CLAIM_SCOPE` and again at each `claims.append` in `main.py`.
|
||||
* **Getting it wrong is the parked-battery bug, so it is routed rather than
|
||||
written.** A per-inverter reserve filed as a site `hi` against the peak guard's
|
||||
site `lo` is `lo > hi`, arbiter clause 3, **0 W in the billed quarter** -
|
||||
SAFETY-25 §0a's fatal case. `actuator_for()` is the one routing point and it
|
||||
**raises `KeyError` on an unclassified source** rather than defaulting to the
|
||||
site, because defaulting to the site is the failure itself.
|
||||
* **Three stages, each a function a test can construct a case at.**
|
||||
`pre_resolve()` turns one inverter's own claims into that unit's interval;
|
||||
`site_resolve()` turns the site claims into one grid target and **is the
|
||||
shipped arbiter, unchanged**; `allocate()` is **the seam, and deliberately not
|
||||
an allocator** - `ALLOC-01` builds it. With at most one unit it passes the
|
||||
target through (§6.2's N=1 identity); with two or more **it declines, no
|
||||
shares, `allocated=False`**, because the obvious placeholder - hand the target
|
||||
to each - IS the fault `ARCH-01` was filed about. **What `main.py` then does
|
||||
is SUBSTITUTE, not abstain**: it replaces the resolution with a 0 W `failsafe`,
|
||||
logs "refusing to broadcast the site target", and writes that 0 W through
|
||||
`write_setpoint()` like any other cycle. The refusal is to BROADCAST; the
|
||||
write still happens, in the fail-toward-inaction direction. Graded end to end
|
||||
on a real two-inverter cycle by new **part 10h** - the branch is unreachable
|
||||
on the shipped roster, and replacing it with `if False:` had left all 17
|
||||
suites green.
|
||||
* **`resolve()` HONOURS the roster it is handed, and that is now graded too.**
|
||||
Left `None` the roster is derived from the claims, which is the documented
|
||||
default; passed explicitly it is used. Deriving it *always* - ignoring the
|
||||
argument - makes a unit that filed nothing this cycle cease to exist, so a
|
||||
site of two reads as a site of one and the seam passes the whole grid target
|
||||
through to the inverter that spoke: `ARCH-01`'s fault with its own evidence
|
||||
removed. `test_arbiter.py` part 7 grades it on the one case that separates the
|
||||
two, a **silent unit**.
|
||||
* **The contradiction is no longer guarded against, it CANNOT BE WRITTEN DOWN.**
|
||||
The partition is by `actuator` and it is a partition: a unit's `hi` and the
|
||||
site's `lo` are never both terms of one `lo > hi` test. Constructed and swept -
|
||||
40 filings (every per-inverter source x unit x bound, a unit contradicting
|
||||
ITSELF included) against a live site floor, and not one moves the site target
|
||||
or raises a contradiction. A unit's own impossible pair parks that unit and
|
||||
says so on its own bounds; it does not park the site. That is SAFETY-25 §0c's
|
||||
table made mechanical.
|
||||
* **At N=1 nothing splits, and that is §6.2's identity rather than the
|
||||
classification being ignored.** With one inverter the fabricated grid reading
|
||||
and the battery setpoint are the same number, so the grid connection and the
|
||||
only unit ARE one actuator and every source routes to the site. **Measured:
|
||||
dropping that identity - splitting at N=1 - takes `test_peakguard.py`,
|
||||
`test_freeze.py` and part 10g red**, because the `failsafe` and `maintenance`
|
||||
SET claims would stop competing for the winner, `explain()` would name a
|
||||
different source and `loop_is_following()` reads that name.
|
||||
* **SAFETY-24's floor asymmetry survives, and now has a second half.** The
|
||||
combination sweep is re-run and still holds - no negative floor, `hi` still
|
||||
`+inf` on every claim the guard files - and it now also asserts every one of
|
||||
them is on the **site** actuator, because a floor bound to one inverter's share
|
||||
would leave the site, the thing the capacity tariff meters, with no floor.
|
||||
* **The part 10f tripwire is kept and widened, not adapted around.** Its static
|
||||
AST scan and its dynamic SoC sweep are untouched in substance - `source` is
|
||||
still `Claim.set()`'s first positional argument precisely so the scan keeps
|
||||
reading it, which is why `actuator` is the LAST field of `Claim` and not the
|
||||
first. Its spy gained `**kw` so the roster passes through unread rather than
|
||||
being silently dropped. New **part 10g** pins `CLAIM_SCOPE` to the same
|
||||
eight-source set, so a ninth source now goes red twice. Verified by breaking
|
||||
it: building SAFETY-25's Option B as a ninth source still takes 10f red on the
|
||||
line it is written.
|
||||
* **And the CALL SITES are pinned statically, at all eight of them.** 10g's
|
||||
first cut graded routing only through a **real two-inverter cycle** and called
|
||||
that "the line a mis-typed `actuator_of(...)` at a call site goes red on".
|
||||
**It was not.** That cycle reaches `device`, `supervised` and `loop` and
|
||||
nothing else - three of the eight direct appends - so a mis-type at the other
|
||||
five survived every suite in this repository. Proved on the shipped tree by PR
|
||||
#40's reviewer: `actuator_of("maintenance")` -> `actuator_of("peak")` at the
|
||||
maintenance-shaping append left `test_arbiter.py`, `test_peakguard.py` and
|
||||
`test_arbitrage.py` all green while, at a roster of two, it built a site loop
|
||||
of -1500 W against the guard's site `lo` of 1500 W and the now-misrouted
|
||||
charge-only `hi = 0` - `lo > hi`, arbiter clause 3, **0 W in the billed
|
||||
quarter**, SAFETY-25 §0a's fatal case from a one-word typo. That is this
|
||||
repository's named failure mode - **a check observing something other than
|
||||
what it claimed** - reproduced inside the check written to prevent it, so it
|
||||
is closed the way 10f closes it: over the **same AST scan**. All eight direct
|
||||
appends expose their actuator as a literal `actuator=self.actuator_of('...')`,
|
||||
so the literal is required to EQUAL the source the claim is filed under - all
|
||||
eight, on the line the typo is written, in every configuration and at every
|
||||
roster, whether or not any fixture reaches the state that files them.
|
||||
**Measured: each of the eight mutated to a wrong actuator in turn, each one
|
||||
red.** The two INDIRECT appends (`peak_claim`, `arb_claim`) carry no
|
||||
`actuator=` at the call site to mis-type, and are pinned where their routing
|
||||
is actually chosen - `peakguard.claim()` by the `SWEEP_SITE` sweep,
|
||||
`arbitrage.claim()` by `test_arbitrage.py`. 10g's dynamic cycle is kept and
|
||||
now says which three of the eight it sees instead of claiming the class.
|
||||
|
||||
**SAFETY-25's open question is ANSWERED: the BMS cut-out is the DELIBERATE and
|
||||
only backstop for demand-driven discharge, and a loop-side reserve floor is
|
||||
DEFERRED to `ALLOC-01` rather than rejected (SAFETY-25).** Decided by the
|
||||
|
||||
@@ -0,0 +1,213 @@
|
||||
# CFG-04 — how a second inverter is declared, and why that shape was measured
|
||||
|
||||
**Status: DECIDED 2026-09-04 — a list of objects, `inverters:`, with `[]` as
|
||||
the shipped default.** The alternative on the table was the `static_profile`
|
||||
precedent: a structured value carried as a JSON **string** in a `str?` option.
|
||||
Both work. The list wins on three counts that were measured rather than argued,
|
||||
and the empty default is not cosmetic — without it the upgrade breaks.
|
||||
|
||||
Filed with CFG-04. Card 6a99fdf9d381935eddce4467.
|
||||
|
||||
---
|
||||
|
||||
## 1. The question, and why it could not be answered from the documentation
|
||||
|
||||
`config.yaml` used `list(off|ha_dsmr|…)` for enums and `str?` for free text, and
|
||||
**there was no list-of-objects anywhere in the file**. `static_profile`
|
||||
(`options:` `""`, `schema:` `str?`) carries a whole tariff structure as one JSON
|
||||
line, and its own comment says why: *"a JSON string rather than a nested schema,
|
||||
deliberately … it survives config.yaml's flat options block"*. That comment is
|
||||
evidence that a nested schema was **doubted**, not that it was tried.
|
||||
|
||||
So the question was not "is this expressible in YAML" but **"does the Supervisor
|
||||
this site actually runs accept it"** — and the Supervisor pins the options schema
|
||||
to the *installed* version (`docs/pickup.md`), so guessing wrong is not a
|
||||
compile error, it is an operator whose add-on will not start after an update
|
||||
(`docs/deploy-rollback.md` §4, in the forward direction).
|
||||
|
||||
## 2. How it was answered
|
||||
|
||||
`tools/supervisor_shape_probe.py`, committed beside this record, runs
|
||||
**Supervisor's own `AppOptions` validator and its own `SCHEMA_APP_CONFIG`** out
|
||||
of the release image — `ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0`
|
||||
— against **this repository's `config.yaml`**. 2026.08.0 is the version the live
|
||||
install reports (`supervisor_version` in its own backup metadata, 2026-09-03,
|
||||
alongside Home Assistant 2026.8.3).
|
||||
|
||||
Nothing was re-implemented: if the Supervisor changes its rules, the script
|
||||
changes its answer. Nothing was touched, either — it reads the file and runs a
|
||||
validator in a throwaway container. It does **not** talk to the live Supervisor
|
||||
and does not POST options, because the schema conflict is the one thing you do
|
||||
not want to discover on a running site.
|
||||
|
||||
### What it printed, 2026-09-04
|
||||
|
||||
⚠️ **This transcript was RE-RUN after review, against the same image tag, and
|
||||
it is not the one this record first carried.** The first §B validated the
|
||||
reconstructed live blob — a blob missing many required keys that have nothing
|
||||
to do with this card — and quoted its refusal as evidence about `inverters`.
|
||||
It never was: that refusal names whichever unrelated key the validator reaches
|
||||
first, and it has printed `meter_freeze_s`, `p1_phase_export_entities` and
|
||||
`sign_disagree_w` on three different runs. §B is now the isolated
|
||||
counterfactual — the shipped `options:` block, and the same block with
|
||||
`inverters` and nothing else removed — and it asserts on the KEY NAME in the
|
||||
refusal. The mis-cited half is kept, relabelled, as §B2. See §4.
|
||||
|
||||
```
|
||||
App 'GoodWe RS485 Controller' uses deprecated 'arch' values: ['armv7']
|
||||
Option 'inverters' does not exist in the schema for GoodWe RS485 Controller (local_goodwe_controller)
|
||||
== A. the whole config.yaml through SCHEMA_APP_CONFIG ==
|
||||
PASS Supervisor accepts the add-on manifest, version 0.6.0
|
||||
schema declares 66 keys; inverters -> [{"name": "str", "setpoint_entity": "str", "max_w": "int(100,5000)", "soc_entity": "str?", "batt_entity": "str?", "batt_invert": "bool?"}]
|
||||
options ship inverters -> []
|
||||
|
||||
== B. THE LOAD-BEARING ONE: an options blob with no `inverters` key ==
|
||||
PASS the shipped `options:` block validates AS IT STANDS - so anything refused on the next line is refused for the one key that was removed
|
||||
PASS ...and the SAME block with ONLY `inverters` removed is REFUSED, BY NAME - which is every options blob written before 0.6.0, since the key did not exist when they were written
|
||||
Missing option 'inverters' in root in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
|
||||
== B2. AC3: a reconstructed pre-0.6.0 blob upgrades into this version ==
|
||||
PASS the reconstructed raw blob is REFUSED - for an unrelated missing key, because the reconstruction is incomplete; see the refusal printed below and §B for the `inverters` measurement
|
||||
Missing option 'sign_disagree_w' in root in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
PASS the same blob MERGED with these defaults - what App.options actually is
|
||||
inverters=[] setpoint_entity='number.kelder_goodwe_master_stage1_goodwe_setpoint_w' max_w=5000
|
||||
|
||||
== C. AC2: a two-inverter blob an operator would POST ==
|
||||
PASS two inverters
|
||||
[{"name": "inverter-a", "setpoint_entity": "number.goodwe_a_setpoint_w", "soc_entity": "sensor.goodwe_a_soc", "batt_entity": "sensor.goodwe_a_battery_power", "max_w": 5000}, {"name": "inverter-b", "setpoint_entity": "number.goodwe_b_setpoint_w", "soc_entity": "sensor.goodwe_b_soc", "batt_entity": "s
|
||||
|
||||
== D. what the schema itself refuses, per entry ==
|
||||
PASS an entry with no name is refused
|
||||
Missing option 'name' in inverters in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
PASS an entry with no setpoint_entity is refused
|
||||
Missing option 'setpoint_entity' in inverters in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
PASS an entry with no max_w is refused
|
||||
Missing option 'max_w' in inverters in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
PASS an entry with max_w over the range is refused
|
||||
value must be at most 5000.0
|
||||
PASS a JSON STRING where the list belongs is refused
|
||||
Invalid list for option 'inverters' in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
|
||||
== E. the ROLLBACK direction, and the operator's UI ==
|
||||
PASS a schema WITHOUT `inverters` drops the key with a warning rather than refusing - so a downgrade is not the §B trap in reverse
|
||||
['arbitrage_enabled', 'arbitrage_soc_ceiling', 'arbitrage_soc_floor', 'auto_start', 'batt_entity', 'batt_invert']
|
||||
PASS Supervisor's UI renderer turns it into a repeatable section rather than choking - an operator can add the second inverter in the Configuration tab, which the JSON-string alternative could not offer
|
||||
[{"name": "inverters", "type": "schema", "optional": true, "multiple": true, "schema": [{"name": "name", "required": true, "type": "string"}, {"name": "setpoint_entity", "required": true, "type": "string"}, {"name": "max_w", "lengthMin": 100.0, "lengthMax": 5000.0, "required": true, "type": "integer
|
||||
|
||||
== all cases passed ==
|
||||
```
|
||||
|
||||
*(`arch: armv7` deprecation is pre-existing and unrelated.)*
|
||||
|
||||
## 3. What that establishes, item by item
|
||||
|
||||
| Claim | Evidence |
|
||||
|---|---|
|
||||
| A list of objects is a legal `schema:` element | §A — the whole manifest passes `SCHEMA_APP_CONFIG`, whose `SCHEMA_ELEMENT` explicitly permits `[{str: Self}]` |
|
||||
| Per-entry types are enforced | §D — `max_w: 9999` refused with *"value must be at most 5000.0"* |
|
||||
| A missing required key is refused **by name** | §D — *"Missing option 'name' in inverters"* |
|
||||
| A two-inverter blob validates | §C |
|
||||
| The operator can edit it in the UI | §E — `UiOptions` renders `{"type": "schema", "multiple": true}` |
|
||||
| The `inverters: []` default is what makes a pre-0.6.0 blob validate | §B — the shipped defaults **minus only that key** are refused with *"Missing option 'inverters' in root"*; unmodified they pass |
|
||||
| A downgrade drops the key rather than refusing | §E — a schema without `inverters` **drops the key with a warning**; it is not the §B trap in reverse |
|
||||
|
||||
## 4. ⚠️ The one that decided the default: `inverters: []`
|
||||
|
||||
§B is the load-bearing measurement, and it is an **isolated counterfactual**:
|
||||
exactly one key differs between its two runs. `supervisor/apps/options.py`'s
|
||||
`_check_missing_options()` treats a nested list as **required** unless its
|
||||
element is an optional scalar — a list whose element is a dict is never
|
||||
optional. So the shipped `options:` block validates as it stands, and the same
|
||||
block with **only** `inverters` removed is answered with:
|
||||
|
||||
```
|
||||
Missing option 'inverters' in root in GoodWe RS485 Controller (local_goodwe_controller)
|
||||
```
|
||||
|
||||
The live install's stored options have no such key, because it did not exist
|
||||
when they were written. If `config.yaml` declared `inverters:` in `schema:` and
|
||||
**not** in `options:`, then on update `App.test_update_schema()` would log *"new
|
||||
schema is not compatible"* and the operator would be left with an add-on that
|
||||
will not start — and the schema they would need to fix it with is pinned to the
|
||||
version they cannot install.
|
||||
|
||||
What makes it safe is that `App.options` is
|
||||
`deepmerge(config.yaml's options:, the operator's persisted options)`, so a
|
||||
shipped `[]` fills the gap before validation ever runs. §B shows the halves that
|
||||
carry the claim — the defaults **minus this one key refused, by this key's
|
||||
name**, and the unmodified defaults **accepted** — and §B2 shows the merge doing
|
||||
its job on a reconstructed pre-0.6.0 blob.
|
||||
|
||||
⚠️ **What §B2 does NOT show, and what this record used to claim it did.** §B2's
|
||||
`LIVE` dict is an incomplete reconstruction: it carries the keys `HANDOVER.md`
|
||||
and `docs/deploy-rollback.md` record and no others, so it is missing many
|
||||
required keys unrelated to this card. Its RAW half is therefore refused for
|
||||
whichever of *those* the validator reaches first — three separate runs have
|
||||
printed `meter_freeze_s`, `p1_phase_export_entities` and `sign_disagree_w` —
|
||||
and the earlier version of this section quoted that refusal as if it named
|
||||
`inverters`. It never did. The string above was produced by §B, where the
|
||||
`inverters` key is the only thing that varies.
|
||||
|
||||
The probe's assertion on that line is on the **key name in the refusal**, not on
|
||||
"a refusal happened". With the weaker assertion §B would have gone on printing
|
||||
PASS after someone deleted `inverters: []` from `config.yaml` — blind to the one
|
||||
regression it is the committed evidence for. It is now checked both ways: with
|
||||
the default deleted the probe prints `2 CASE(S) FAILED` and exits 1; restored,
|
||||
it prints `all cases passed` and exits 0.
|
||||
|
||||
The merge strategy was checked too, because it is the other way this could have
|
||||
gone wrong: `_OPTIONS_MERGER` is `type_strategies=[(dict, ["merge"])]` with an
|
||||
`override` fallback, so **lists override rather than concatenate**. A shipped
|
||||
one-element default plus an operator's two-element list would otherwise have
|
||||
produced three entries — with inverter A declared twice, aimed at one actuator,
|
||||
which is exactly the hazard SAFETY-28 refuses. `[]` makes that unreachable and
|
||||
the override rule means even a non-empty default could not have grown a roster.
|
||||
|
||||
## 5. Why the list, and not the `str?` + JSON precedent
|
||||
|
||||
The JSON string works — §C of the earlier draft of this probe validated the same
|
||||
roster as a `str?` — and if the list had failed it is what would have shipped.
|
||||
It loses on three things:
|
||||
|
||||
1. **SAFETY-28's writer census stops working.** `actuator_writers()` walks the
|
||||
options **tree** looking for `setpoint_entity` at any depth, and its own
|
||||
docstring anticipates this card: *"Add CFG-04's per-inverter config — a list
|
||||
of inverters, each with its own `setpoint_entity` — and there are two real
|
||||
writers"*. Inside a JSON **string** those entities are invisible to it, so
|
||||
the §1.5 two-writers guarantee would have had to be re-implemented against a
|
||||
parsed copy — a second place for the census to be wrong.
|
||||
2. **No per-field validation.** With `str?` the Supervisor sees one opaque
|
||||
string: a typo'd rating, a missing name and a malformed entity id all arrive
|
||||
at the add-on identically, and every error message has to be written here.
|
||||
§D shows the Supervisor doing that work, in its own words, before the add-on
|
||||
starts.
|
||||
3. **No UI.** §E renders a repeatable section; a `str?` renders a text box into
|
||||
which an operator hand-types JSON. `static_profile` accepts that cost because
|
||||
§14 gives it exactly one key and its structure is a tariff document; a roster
|
||||
is a list of devices an operator adds one at a time.
|
||||
|
||||
## 6. What is deliberately NOT in the shape
|
||||
|
||||
- **No per-entry defaults.** `name`, `setpoint_entity` and `max_w` are
|
||||
**required**; the sensors are optional and their absence means *this unit has
|
||||
no such sensor*, never *use the other one's*. CFG-03 keeps defaults in exactly
|
||||
one place, and a per-entry default would be a second one — worse, it would be
|
||||
a per-entry default whose value is another inverter's measurement, which is
|
||||
the sibling-grading defect DEV-02 spent a card removing.
|
||||
- **No `gain`, `slew_w`, `integrator_max_w` per entry.** §6.2 and ALLOC-01 are
|
||||
ONE integrator on P1 above the split. `app/inverter.py`'s module docstring
|
||||
carries that argument; the config must not make a second one expressible.
|
||||
- **No `inverters` entry for the flat keys.** They ARE the single-inverter
|
||||
shape. Declaring both is refused (rule 9e) rather than merged, because a
|
||||
config that silently becomes a different config is worse than one that
|
||||
refuses to load.
|
||||
|
||||
## 7. Revisit triggers
|
||||
|
||||
- **A Supervisor upgrade that changes `AppOptions`.** Re-run the probe with the
|
||||
new version tag. The whole point of committing it is that this costs a minute.
|
||||
- **SPIKE-04 measuring inverter B.** It supplies a real `max_w` for the second
|
||||
entry. It does not change the shape.
|
||||
- **A second `Maintenance` FSM.** `validate.py` rule 6 grades
|
||||
`maintenance_charge_w` against the first entry of `unit_caps_indexed()`
|
||||
because `Controller.maint_unit` is `inverters[0]`. When that stops being true, that line moves with it.
|
||||
@@ -0,0 +1,388 @@
|
||||
# MAINT-05 — one recalibration per pack, one at a time, and what the card left open
|
||||
|
||||
**Status: DECIDED 2026-09-04.** There is one `Maintenance` per roster entry,
|
||||
each with its own schedule, phase and history. The site holds exactly **one
|
||||
maintenance slot**: at most one pack may be in a power-moving phase, the slot is
|
||||
derived from the packs' own stored phases rather than persisted separately, and
|
||||
when several packs are due in the same hour it goes to the one that has gone
|
||||
**longest without a completed cycle**. The schedule is **not** staggered by
|
||||
construction — the interlock defers, and the stagger emerges from it.
|
||||
|
||||
**Fix round 2026-09-04.** The store migration is now graded against the
|
||||
**roster** rather than against the unit name it was handed — see §2's
|
||||
*"The read-back postcondition is graded against the ROSTER"* — and the same
|
||||
hole in SAFETY-02's latch migration is recorded in §7.
|
||||
|
||||
Filed with MAINT-05. Card `6a9a9e8503872905f298d80a`.
|
||||
|
||||
---
|
||||
|
||||
## 0. What the card asked to be decided, and the answers
|
||||
|
||||
| the card's open question | the decision |
|
||||
|---|---|
|
||||
| §2 the arbitration | **one pack at a time; the other stays under the loop.** Nothing preempts a cycle in flight. |
|
||||
| §2 who wins when several are due | **the longest-waiting pack**, `last_completed` oldest first, `inf` for never-recalibrated. Roster order breaks a numeric tie and nothing else. |
|
||||
| §4 staggering | **not by construction.** The interlock defers the second pack; the stagger is what comes out of it. §3 below. |
|
||||
| AC 7 rule 6's `maint_unit` comment | **no, the first entry's cap is no longer right.** It grades against the weakest cap on the roster now, like rule 5. §4 below. |
|
||||
| the store layout at N=1 | **flat, unchanged.** The namespace appears the day the roster grows. §2 below. |
|
||||
|
||||
## 1. Why the slot is derived and not persisted
|
||||
|
||||
The holder is *"whichever pack's stored phase is not `idle`"* — a fact already on
|
||||
disk, written by the packs themselves in the per-pack history this card
|
||||
introduces. A `maint_slot_holder` key would be a **second opinion about the same
|
||||
thing**, and the two would disagree the first time the add-on was killed between
|
||||
writing the phase and writing the holder. Derived, a controller that comes back
|
||||
up mid-drain reads the drain and re-derives the holder from it; there is no
|
||||
recovery path to get wrong because there is no second fact.
|
||||
|
||||
`CHARGE` is in `POWER_MOVING` even though the control **loop** owns the setpoint
|
||||
in that phase, and that is the decision most likely to be "simplified" later.
|
||||
Pack A charging from the grid at 2000 W while pack B drains 2000 W to export is
|
||||
4 kW going round in a circle with the meter reading zero and both packs
|
||||
believing they are behaving — the circulating power [[SAFETY-31]] exists to
|
||||
detect, arriving as something this module can simply not do. `HOLD` is in the
|
||||
tuple for the other half of the sentence: it moves nothing, and it **owns the
|
||||
actuator**, so a second cycle starting under it would still be two
|
||||
recalibrations at once.
|
||||
|
||||
## 2. Why the store layout at a roster of one does not change
|
||||
|
||||
The maintenance keys are flat — `phase`, `phase_started`, `last_completed`,
|
||||
`last_start_attempt` — on every install since the add-on shipped. At one pack
|
||||
there is nothing for a namespace to distinguish that pack **from**: §6.2's
|
||||
identity, the same one `arbiter.actuator_for()` leans on when it routes every
|
||||
claim to the site actuator at N=1. So `Maintenance` is constructed with
|
||||
`unit=None` there, reads and writes the flat keys directly, and
|
||||
`migrate_maint_keys()` **returns without writing anything**. A one-inverter state
|
||||
file comes out of this card byte-identical, which is AC 6 and which
|
||||
`test_maintenance.py` part 10 asserts by driving a whole cycle and comparing the
|
||||
key set.
|
||||
|
||||
### The migration has its own marker, and that is not tidiness
|
||||
|
||||
`SCHEMA_VERSION` / `schema_version` is DEV-02's, and it is **monotone**: every
|
||||
install runs that migration exactly once. This one runs **only where the roster
|
||||
has more than one pack**, so a single counter could not express *"migrated on
|
||||
this site, deliberately not migrated on that one"* without lying to the next
|
||||
version that reads it — a one-inverter store would have to be pinned at the old
|
||||
number forever, and a genuine future v2 migration could then never be told apart
|
||||
from a site that simply never grew. `maint_schema_version` answers one question
|
||||
and answers it honestly.
|
||||
|
||||
The **three rules are shared in code**, not restated: `_move_flat_keys()` is
|
||||
rule 1 (never overwrite an existing namespaced value) and rule 2 (the flat keys
|
||||
stay in the file), `_verify_moves()` is the read-back postcondition, and the
|
||||
marker is written last. A second transcription of a migration is a second
|
||||
opinion about what "it landed" means.
|
||||
|
||||
### The read-back postcondition is graded against the ROSTER (fix round)
|
||||
|
||||
**A postcondition that reads back the namespace it was handed cannot detect
|
||||
being handed the wrong one.** That sentence is the whole finding, and this card
|
||||
shipped it broken.
|
||||
|
||||
`_verify_moves()` iterated `rep.moved` — the keys it had just written — and
|
||||
asked whether each read back equal. On a store where the write lands, it always
|
||||
does. So a migration handed a `unit` that is on no roster wrote four keys, read
|
||||
four keys back, set `verified = True`, and the caller stamped
|
||||
`maint_schema_version`. Every symptom of a clean migration, and an install's
|
||||
whole maintenance history parked under a name nothing will ever look up. And
|
||||
because the marker was stamped, **the next start skipped the migration too** —
|
||||
which is precisely the state `store.py`'s header says must never happen: a
|
||||
failed migration a later version treats as done.
|
||||
|
||||
Reproduced on the reviewer's roster, a house with a garage pack and a shed pack,
|
||||
carrying a flat `last_completed` of 2026-08-07:
|
||||
|
||||
| | `unit` the migration was handed | key written | pack 0 reads back | due now? |
|
||||
|---|---|---|---|---|
|
||||
| correct | `self.inverters[0].name` = `garage` | `unit/garage/last_completed` | `2026-08-07` | **False** |
|
||||
| wrong | `inverter.UNIT_A` = `inverter-a` | `unit/inverter-a/last_completed` | `None` | **True** |
|
||||
|
||||
`build_roster()` names a declared roster's entries **from the config**, and its
|
||||
fallback for a nameless entry is a **positional** `inverter-1` — so `inverter-a`
|
||||
is not the name of anything on a declared roster, not even by default.
|
||||
|
||||
**The remedy, and why this one.** `migrate_maint_keys()` now takes the **roster**
|
||||
in place of an `n_units` count (the count was `len(self.inverters)` at the only
|
||||
call site, so the roster carries it, and a count passed beside the names is a
|
||||
second opinion about how many packs there are). `_verify_moves()` grades the
|
||||
namespace it wrote against those names, and a unit that is not among them is
|
||||
reported as `misdirected` — a **different** failure from `lost`:
|
||||
|
||||
* `lost` is *the store took the write and dropped it* — a storage fault, and it
|
||||
has a harmless-default case (a write of `last_completed: None` loses nothing,
|
||||
because "absent" and "never recalibrated" are the same statement).
|
||||
* `misdirected` is *the store did exactly as it was told, by a caller that was
|
||||
wrong*. There is no harmless-default version of it: a write nobody reads is
|
||||
not information, whatever its value. So anything in it fails `ok` on its own.
|
||||
|
||||
And **`ok` gates the marker**, so a misdirected migration is not stamped and the
|
||||
next start runs it again. The argument for it is asymmetric: a re-run is
|
||||
recoverable — rule 1 makes it a no-op where keys did land, and rule 2 left the
|
||||
flat keys in the file to recover *from* — while a silent skip is not recoverable
|
||||
at all, because the store now claims the migration happened.
|
||||
|
||||
### ⚠️ THE PARAGRAPH ABOVE USED TO END HERE, AND AS IT STOOD IT WAS FALSE
|
||||
|
||||
**The refusal lasted exactly one start. The second start stamped the marker.**
|
||||
That is a correction to what the first fix round wrote down, not a new
|
||||
qualification of it, and it is recorded here because a decision document that
|
||||
states a guarantee the code does not provide is worse than one that says
|
||||
nothing.
|
||||
|
||||
`_verify_moves()` graded only `rep.moved`. Measured at Controller level over
|
||||
**one persisted store**, roster `["garage", "shed"]`, flat `last_completed`
|
||||
2026-08-07, with the call site still handing `inverter-a` on **both** starts:
|
||||
|
||||
```
|
||||
construction 1: ok=False misdirected=4 moved=4 kept=0 marker=<absent> (withheld)
|
||||
construction 2: ok=True misdirected=0 moved=0 kept=4 marker=1 (STAMPED)
|
||||
history parked under unit/inverter-a/…; marker stamped after ONE restart.
|
||||
```
|
||||
|
||||
On start 2 the same wrong call site finds the four keys it wrote already
|
||||
present, so **rule 1** — never overwrite a namespaced value — routes every one
|
||||
of them to `rep.kept`. `rep.moved` is empty, the roster-grading loop iterates
|
||||
over nothing, `misdirected` is empty, `ok` is True, the marker is stamped, and
|
||||
start 3 takes the `from_version >= MAINT_SCHEMA_VERSION` early return **forever
|
||||
— including after the call site is fixed**. Loud-and-recoverable became
|
||||
silent-and-permanent after one restart: exactly the state `store.py`'s header
|
||||
says must never happen, reached by the fix written to prevent it.
|
||||
|
||||
**The remedy is one line**, and it is sound by construction rather than by
|
||||
argument: grade `set(rep.moved) | set(rep.kept)`. Every entry in *both* lists is
|
||||
a `unit_key(unit, legacy)` built from the **same** `unit` argument, so grading
|
||||
`kept` grades the same namespace decision `moved` does. A correct call site's
|
||||
`kept` entries are under a roster name and pass; a wrong one cannot launder its
|
||||
namespace by having already written it. `migrate_unit_keys()` passes
|
||||
`roster=None` and returns before the loop, so it is unaffected.
|
||||
|
||||
**Why the check missed it, which is the part worth keeping.** Part 9b's recovery
|
||||
check was `migrate_maint_keys(_m5, ROSTER[0], ROSTER)` — the **corrected** name.
|
||||
It measures recovery along the one path where the operator has *already fixed
|
||||
the bug*. The real failure is a call site that is still wrong on the next start,
|
||||
and nothing in the 19 files called `migrate_maint_keys()` twice with the **same
|
||||
wrong** `unit`. The check was true, passed, and could not reach the failure its
|
||||
sentence named — MUTATION.md's third defect, this time sitting inside the fix
|
||||
written to close it. Part **9c** now drives two starts with the same wrong unit
|
||||
over one store, asserts the marker is still withheld on the second, and asserts
|
||||
the *shape* of the second report (`moved` empty, `kept` full) so it cannot
|
||||
quietly revert to 9b's path.
|
||||
|
||||
### The marker gate is `rep.ok` and nothing weaker — both guards, each pinned
|
||||
|
||||
`if rep.ok:` is `not lost and not misdirected`, and until this round only the
|
||||
`misdirected` half was reachable by a check that also had a non-empty `kept`.
|
||||
The mutation
|
||||
|
||||
```
|
||||
if rep.ok: -> if rep.ok or rep.kept:
|
||||
```
|
||||
|
||||
stamps the marker on a migration that **lost a month of history** — defeating
|
||||
the older, settled `lost` guard as well as the new one — and **all 19 suites
|
||||
were green on it**. Part **9d** is the fixture that separates them: two keys
|
||||
already namespaced (`kept` non-empty, so the mutant's `or` fires) and two keys
|
||||
whose write the store drops (`lost` non-empty, so `ok` is False), with
|
||||
`misdirected` empty throughout so the section cannot pass on the other guard by
|
||||
accident. Measured differential on it: shipped → marker absent; mutant → marker
|
||||
`1`, both reporting `ok=False lost=2 kept=2`.
|
||||
|
||||
**Why the fixtures had to change, and this is the part that got the card
|
||||
rejected.** Nothing in the repository could see whether any of the above was
|
||||
true, because `inverter.UNIT_A` **is** the string `"inverter-a"` and every
|
||||
two-pack fixture in `test_maintenance.py` named its first roster entry
|
||||
`inverter-a`. `self.inverters[0].name` and `UNIT_A` were therefore the same
|
||||
value in every check that existed, and swapping one for the other at the call
|
||||
site left **all 19 suites green**. MUTATION.md's third defect exactly — a check
|
||||
whose *data* cannot reach the failure it names — and the fifth consecutive card
|
||||
to carry it. Parts 9 and 11 now run on `["garage", "shed"]`, each behind a
|
||||
**precondition check** asserting that the first name is not `UNIT_A`, so an edit
|
||||
that makes them equal again goes red instead of making the claims vacuous.
|
||||
|
||||
### And the flat keys are kept LIVE, which is the half DEV-02 had to add later
|
||||
|
||||
Rule 2 originally said the flat keys are left in place and go stale. DEV-02
|
||||
amended it, for the sign latch, to *"left in place is not enough"* — and the
|
||||
same sentence holds for history. A fossil dated the day the second inverter was
|
||||
declared would hand a rolled-back single-FSM add-on a `last_completed` months
|
||||
old (it recalibrates a pack that does not need it) or a stale `phase` with a
|
||||
`phase_started` old enough to abort on the 12 h timeout the moment it comes up.
|
||||
So `UnitHistory` **mirrors the first pack's writes back onto the flat keys** for
|
||||
as long as the roster has more than one entry. Only the first pack: the flat
|
||||
spelling means `inverters[0]` on every install that has one, and a mirror from
|
||||
pack B would overwrite pack A's rollback view with pack B's phase.
|
||||
|
||||
## 3. Staggering: the interlock defers, and the stagger is the residue
|
||||
|
||||
Two packs on one monthly schedule are due in the same hour every month. The
|
||||
options were a stagger **by construction** — offset each pack's first cycle by
|
||||
`interval_days / N` — or **deferral**. Deferral, for three reasons:
|
||||
|
||||
1. **A constructed stagger cannot remove the need for the interlock.** A forced
|
||||
start, a commissioning cycle, an abort-and-retry, or a pack added mid-month
|
||||
desynchronises any static offset immediately, so the interlock has to be
|
||||
there anyway — and then the stagger is a second mechanism that must also be
|
||||
correct, for a case the first one already handles.
|
||||
2. **A deferral is observable and a stagger is not.** The deferred pack says, in
|
||||
the action log and on the status page, that it is waiting, which pack it is
|
||||
waiting for, and that it will run at the next start hour. A silent offset
|
||||
moves an operator's configured start day and explains nothing.
|
||||
3. **The stagger comes out of the deferral for free and then persists.** Pack A
|
||||
completes on day 1 and is next due on day 29; pack B, deferred, completes on
|
||||
day 2 and is next due on day 30. One contested month separates them by one
|
||||
cycle length and they stay separated.
|
||||
|
||||
**Starvation was the risk and it is closed at two points.** A deferral does
|
||||
**not** stamp `last_start_attempt` — that key is the post-abort cooldown, and at
|
||||
90 minutes inside a 60-minute start hour, stamping it would lock the deferred
|
||||
pack out of exactly the hour it is waiting for. And the winner is the
|
||||
longest-waiting pack rather than the first in the roster, so a pack that keeps
|
||||
aborting cannot monopolise the slot month after month while its sibling drifts —
|
||||
which is this card's own defect wearing a different costume.
|
||||
|
||||
**The deferral must not read as a fault.** §12's 12 h and 36 h phase timeouts
|
||||
mean *"the battery is not following commands"*. A deferred pack stays `IDLE`
|
||||
with `phase_started` untouched, so no timeout is reachable by waiting, and the
|
||||
line it logs says WAITING, names the pack it waits for and says it will run
|
||||
next — none of which any failure path in `maintenance.py` says.
|
||||
|
||||
## 4. Rule 6 (the card calls it rule 8): the first entry's cap is no longer right
|
||||
|
||||
`validate.py`'s rule 6 comment said, in as many words, that
|
||||
`maintenance_charge_w` was graded against `inverters[0]`'s cap because there was
|
||||
exactly one `Maintenance` and it could only ever recalibrate the first pack —
|
||||
and that taking `min()` would be an over-refusal, because it would refuse *"a
|
||||
5000 W pack being recalibrated beside a 2000 W sibling the cycle never
|
||||
touches"*. It closed: **"when `maint_unit` stops being `inverters[0]`, this line
|
||||
moves with it."**
|
||||
|
||||
It has stopped. Every pack is recalibrated on its own schedule, so **the sibling
|
||||
the cycle never touches does not exist** and the over-refusal argument has no
|
||||
subject. The shaping claim is filed on whichever pack is charging, so the cap
|
||||
that can contradict it is any cap on the roster and the one that contradicts it
|
||||
first is the smallest.
|
||||
|
||||
**This refuses configurations that used to start**, and that is the point rather
|
||||
than a side effect: `max_w` 5000 on pack A beside 2000 on pack B with
|
||||
`maintenance_charge_w` 3000 was correct while only pack A was ever recalibrated,
|
||||
and is now a cheap-window charge asking the arbiter for `hi = -3000` against a
|
||||
supervised `lo = -2000` — `lo > hi`, arbiter clause 3, 0 W, on the pack nobody
|
||||
was watching. Refused when it is **written**, which is rule 6's whole job. At a
|
||||
roster of one `min()` over one cap is that cap: same comparison, same message,
|
||||
same boundary.
|
||||
|
||||
## 5. The claim stays per-unit, and nothing here files a site claim
|
||||
|
||||
`arbiter.CLAIM_SCOPE` has classified `maintenance` as `SCOPE_UNIT` since it was
|
||||
written. Two FSMs mean two claims on two actuators, which the allocator consumes
|
||||
as per-unit intervals. [[ARCH-01]] is explicit that this must never become a
|
||||
site claim, because per-inverter constraints filed site-wide are the
|
||||
cross-inverter `lo > hi` contradiction at `arbiter.py:114`. The only line this
|
||||
card changed there is **which** roster entry the claim is filed on: the one whose
|
||||
state machine produced the result, rather than `inverters[0]`.
|
||||
|
||||
## 6. FOUND AND NOT FIXED: the site loop still contradicts a drain at N>=2
|
||||
|
||||
Measured while wiring this card, and **pre-existing on `release/1.0` at
|
||||
`2d025ee`** — the same drain filed on `inverters[0]` produces the identical
|
||||
refusal with the two unit names swapped.
|
||||
|
||||
The maintenance SET **pins** its pack. The loop's target is a **site** claim.
|
||||
When the site target is *below* the pin — a 2000 W drain while the house imports
|
||||
less than that, which is most of a night — the only split that sums to the site
|
||||
target asks the sibling to **charge** while the maintained pack **discharges**,
|
||||
and `allocator.plan()` refuses it by name as circulating power. The refusal is
|
||||
correct and fails safe: the whole site goes to 0 W with an `ARBITER: REFUSED`
|
||||
line in the action log.
|
||||
|
||||
**The consequence an operator would see is a misdiagnosis.** The pack is held at
|
||||
0 W while its state machine believes it is draining, so after 12 h the DRAIN
|
||||
timeout fires and reports *"drain stuck"* — §12's words for a battery that is not
|
||||
following commands. The battery is fine; the site refused to allocate.
|
||||
|
||||
**Why it is not fixed here.** The fix is to change what the site loop's target
|
||||
*means* while a unit is pinned — regulate the meter using only the unpinned
|
||||
packs — which is loop and allocator territory and changes the integrator's
|
||||
subject. MAINT-05 moves which pack is pinned and nothing else about it. It is
|
||||
pinned as a running check (`test_maintenance.py` part 12) rather than left as a
|
||||
comment, so it cannot be forgotten or quietly tuned away, and it wants a card of
|
||||
its own.
|
||||
|
||||
## 7. FOUND AND NOT FIXED: `migrate_unit_keys()` has the same hole, and it is a LATCH
|
||||
|
||||
Found while fixing §2's instance. It is the same defect one module over and it
|
||||
costs a **disarmed safety guard** rather than a lost history.
|
||||
|
||||
`Controller.__init__` calls `migrate_unit_keys(store, UNIT_A)` — a hardcoded
|
||||
constant where the maintenance migration now passes the roster's own first name.
|
||||
It **has** to run before `build_roster()`, because each `Inverter` restores its
|
||||
sign latch in its constructor, so there is no roster to name yet and
|
||||
`_verify_moves()` is passed `roster=None`. On a **declared** roster a pre-DEV-02
|
||||
`sign_tripped: true` therefore lands under `unit/inverter-a/sign_tripped`, which
|
||||
no unit on that site reads.
|
||||
|
||||
**And the guard that exists for exactly this is defeated by the key the defect
|
||||
wrote.** `_grade_store_migration()` re-arms the latch when the flat key says
|
||||
tripped and *nothing namespaced is latched*. The misdirected write **is**
|
||||
namespaced and **is** latched, so `namespaced_latched` is `True`, the guard
|
||||
returns, and no inverter on the roster comes up tripped — on an install whose
|
||||
`/data/state.json` still reads `sign_tripped: true`. That is DEV-02's own
|
||||
sentence for the worst case: the state file says protected, the banner is green,
|
||||
and the controller resumes commanding into the fault that tripped it.
|
||||
|
||||
Measured, on the same `["garage", "shed"]` roster:
|
||||
|
||||
```
|
||||
pre-DEV-02 flat latch + declared roster ['garage', 'shed'] ->
|
||||
migrated 2 flat key(s): unit/inverter-a/sign_reason, unit/inverter-a/sign_tripped
|
||||
latch keys in the store: ['sign_tripped', 'site_sign_tripped', 'unit/inverter-a/sign_tripped']
|
||||
roster came up tripped: [('garage', False), ('shed', False)]
|
||||
the same store on the FLAT config -> [('inverter-a', True)]
|
||||
```
|
||||
|
||||
The last line is the counterfactual: on the flat shape, where `UNIT_A` really is
|
||||
the roster's only name, the same store migrates and comes up latched. So this is
|
||||
a defect of the **declared roster**, not of the migration as such.
|
||||
|
||||
**Why it is not fixed here.** The remedy is to name the migration's target from
|
||||
the config before any `Inverter` exists, which means factoring `build_roster()`'s
|
||||
naming rule out of `build_roster()` so there is still only **one** spelling of
|
||||
it — `inverter.py` and SAFETY-02's latch semantics, with its own mutation battery
|
||||
over `test_inverter.py` and `test_watchdog.py`. MAINT-05 moves the maintenance
|
||||
history and nothing about the sign latch, and a silent expansion into a safety
|
||||
latch is how a rejected PR becomes a broken one.
|
||||
|
||||
It is pinned as a running check (`test_maintenance.py` part 13) rather than left
|
||||
as a comment. ⚠️ **Its assertions state the WRONG behaviour on purpose** — read
|
||||
them as the specification of a defect; the card that fixes it should expect them
|
||||
to go red and should replace them.
|
||||
|
||||
### And its MARKER GATE had the round-3 hole too — found here, closed here
|
||||
|
||||
Separate from the namespace hole above, and **fixed** rather than recorded,
|
||||
because closing it cost one test fixture and no source change.
|
||||
`migrate_unit_keys()` gates `schema_version` on `rep.ok` exactly as
|
||||
`migrate_maint_keys()` gates its own marker, and every check that reached that
|
||||
gate ran on a store where **nothing** was namespaced yet — so `rep.kept` was
|
||||
empty in all of them and
|
||||
|
||||
```
|
||||
if rep.ok: -> if rep.ok or rep.kept:
|
||||
```
|
||||
|
||||
**survived all 19 files**. What it does is stamp the schema marker on a
|
||||
migration that DROPPED THE LATCH: the guard is off, the state file still reads
|
||||
`sign_tripped: true`, and because the store now says the migration finished, the
|
||||
next start skips the one thing that would have re-armed it. DEV-02's own worst
|
||||
case, filed under *done*.
|
||||
|
||||
`test_inverter.py` part 10 now drops the `sign_tripped` write **beside an
|
||||
already-namespaced `sign_reason`** — `lost` non-empty *and* `kept` non-empty,
|
||||
which is the one shape none of the existing fixtures had — and asserts the
|
||||
marker is withheld, with the accepted-baseline counterfactual beside it (habit
|
||||
7). The shipped gate was correct throughout; what changed is that a check can
|
||||
now see it.
|
||||
@@ -0,0 +1,474 @@
|
||||
# SAFETY-30 — what the sign watchdog compares once there is more than one inverter, and the numbers it compares with
|
||||
|
||||
**Status: DECIDED 2026-09-04.** The one comparison becomes **two**, asked of the
|
||||
evidence that can answer each: **each unit's standing command against that
|
||||
unit's own measured power** (register 0x0518, per-instance since [[DEV-02]]),
|
||||
and **the sum of the standing commands against the meter**. At a roster of one
|
||||
nothing changes at all — the two questions are the same sentence there, and the
|
||||
detector that ships is the only one armed.
|
||||
|
||||
This document records the argument for that split, the campaign the four numbers
|
||||
were read off, **a number that was carried and a number that refused to be**, and
|
||||
the mutation ledger. Filed with SAFETY-30, card `6a9a1828e844f22fabf7fe9c`.
|
||||
|
||||
---
|
||||
|
||||
## 0. The half that was already built, and the half this card is
|
||||
|
||||
[[DEV-02]] shipped the **per-instance** half and nothing here re-tests it: each
|
||||
`Inverter` owns its own `SignWatchdog`, the latch is namespaced under
|
||||
`unit/<name>/sign_tripped`, the flat pre-DEV-02 pair is maintained as a rollback
|
||||
view, and a trip on B no longer latches A. `test_inverter.py` part 3 grades that.
|
||||
|
||||
What was left is **the comparison itself**, and it was one line:
|
||||
|
||||
```python
|
||||
inv.sign_wd.evaluate(stood, self.grid, self.following, now) # every unit
|
||||
```
|
||||
|
||||
`stood` is the command **this controller put on THIS actuator**. `self.grid` is
|
||||
what the **whole site** is exchanging with the network. At one inverter those are
|
||||
two views of one thing — §6.2's identity — which is what makes the check sound
|
||||
and what earned its record. At two they are not, and it fails in **both**
|
||||
directions:
|
||||
|
||||
| | what happens | why no threshold fixes it |
|
||||
|---|---|---|
|
||||
| **false trip** | A commanded −1500 W while the meter reads +1500 W, because B is discharging 3000 W exactly as told | the meter is answering for a unit A's command says nothing about |
|
||||
| **missed fault** | B commanded +1500 W and **measured** at −1500 W, beside A at +1500 W — the meter sits where a healthy site leaves it | the summation **destroys** the evidence |
|
||||
|
||||
NOTES.md calls SAFETY-02 the highest-value check in the safety table: 93 %
|
||||
agreement while healthy against 4 % during runaway, four observed episodes, zero
|
||||
false positives. **That record was earned at N=1 on the site comparison.** The
|
||||
first row above spends it; the second row is the guard being absent when it
|
||||
matters.
|
||||
|
||||
## 1. The two questions, and the two remedies
|
||||
|
||||
> **PER UNIT** — this unit's standing command against **its own** measured power.
|
||||
> Conclusion: *the actuator I am driving is not doing what I told it.* Evidence
|
||||
> about one device, so the remedy is that device: the `failsafe` SET, which
|
||||
> `arbiter.CLAIM_SCOPE` has classified `SCOPE_UNIT` since it was written.
|
||||
>
|
||||
> **SITE** — the **sum** of the standing commands against the meter. Conclusion:
|
||||
> *the site as a whole is driving the wrong way* — an inverted gain, an
|
||||
> integrator wound past the rail, a strategy on the wrong side of the meter.
|
||||
> That is the 2026-08-20 fault day, it is a property of the **connection**, and
|
||||
> the remedy is a new SITE SET, `sign_site`, that stops every inverter.
|
||||
|
||||
### Why `failsafe` stays per-unit and `sign_site` is new
|
||||
|
||||
`CLAIM_SCOPE`'s entry for `failsafe` used to read *"the evidence is site-wide and
|
||||
the remedy is not"* — a site measurement attributed to one actuator on the
|
||||
strength of the N=1 identity. After this card the first half of that sentence is
|
||||
simply true: the evidence **is** per-unit. The site-wide half did not disappear;
|
||||
it moved to a claim that is site-scoped for the reason `circulation` is, one
|
||||
entry above it: **the offending number is the site target, which no single
|
||||
inverter owns.** Parking one unit on it would leave the rest of the roster
|
||||
pushing the same way with the guard satisfied.
|
||||
|
||||
### At N=1, exactly one detector is armed
|
||||
|
||||
`Controller._arm_sign_watchdogs()` is the only place the roster decides anything
|
||||
here, and it is a pure function of `len(self.inverters)`:
|
||||
|
||||
* **one inverter** — the unit detector is armed against **the meter**, at the
|
||||
shipped `sign_disagree_w` / `sign_disagree_s`. The site detector is
|
||||
**constructed and never evaluated**. Same comparison, same thresholds, same
|
||||
reason string byte for byte, same namespaced keys and flat mirror, same
|
||||
`failsafe` claim, same banner, same single status row. `test_watchdog.py`
|
||||
part 7 asserts each of those, including that the site detector's window was
|
||||
never so much as opened.
|
||||
* **two or more** — each unit against its own 0x0518 power under the per-unit
|
||||
pair, and the site detector against the meter under the site pair.
|
||||
|
||||
Arming both at N=1 would be two latches and two banners for one fault, and a
|
||||
false-positive record measured on **one** comparison spent twice.
|
||||
|
||||
## 2. What this is NOT — the two neighbours, named
|
||||
|
||||
Two guards that overlap without saying so is how a false-alarm generator gets
|
||||
built, so both are written down.
|
||||
|
||||
### It is not [[SAFETY-31]]
|
||||
|
||||
| | **SAFETY-31 — `circulation.py`** | **SAFETY-30 — the per-unit half** |
|
||||
|---|---|---|
|
||||
| compares | the units **against each other**: `Σ\|Bᵢ\| − \|ΣBᵢ\|` over measured power | each unit against **its own command** |
|
||||
| catches | two inverters pushing **through** each other; nets to zero at the meter | a unit **not doing what it was told**; that unit is faulty or wedged |
|
||||
| attributes | nothing — the quantity is defined over the roster and is identically zero for one unit | **the unit**, by name, and parks it |
|
||||
| scope | SITE claim, flat latch | UNIT claim, namespaced latch |
|
||||
|
||||
They genuinely overlap in **one** scenario — a unit reversing while its sibling
|
||||
pulls the other way — and `test_watchdog.py` part 4 asserts exactly that, on the
|
||||
same fixture, with both readings printed: circulating power is over its threshold
|
||||
**and** SAFETY-30 names B. Neither is the other with a different threshold. Take
|
||||
two units faithfully executing an allocation with two signs: circulating power is
|
||||
the whole loop and every per-unit sign check reads perfect agreement. Take one
|
||||
unit doing the opposite of its share while its sibling covers: this reads the
|
||||
whole disagreement and circulating power can be zero.
|
||||
|
||||
### It is not the saturation freeze
|
||||
|
||||
`compute()`'s anti-windup test is `|prev_w − actual_w| > saturation_w` (500 W). It
|
||||
concludes *the inverter cannot follow*, it fires on a merely **saturated** unit as
|
||||
readily as on a reversed one, it **stops the integrator winding** — an ordinary
|
||||
control action taken every day — and it neither latches nor parks anything.
|
||||
|
||||
This asks for **opposition**: a sign, on both sides of a threshold, held
|
||||
continuously. A saturated-but-obedient unit cannot produce it. And the two meet
|
||||
at a number rather than overlapping in a band nobody drew — see §3.
|
||||
|
||||
## 3. The numbers, and where they come from
|
||||
|
||||
Read off `admin/goodwe`'s `sim/` two-master rig (TEST-19), used **read-only** and
|
||||
run container-free. Real and imported, never transcribed: the control law
|
||||
(`control.compute`, `Tuning`), the allocator (`arbiter.allocate_record` →
|
||||
`allocator.plan`), the sign predicate (`watchdog.disagrees`), the wire
|
||||
(`frame_check.setpoint_atomic`, the firmware's own encoder), the plant
|
||||
(`plantsim.Plant`), and the per-unit reading, taken from **holding register
|
||||
0x0518** — the register the live `batt_entity` binds.
|
||||
|
||||
**1890 closed-loop runs in which NOTHING is faulty** — every unit executes the
|
||||
share the allocator gave it — over **6 gains × 5 slews**, the whole range
|
||||
`config.yaml` accepts for `gain` `float(0.05,1.0)` and `slew_w` `int(50,5000)`,
|
||||
across both families of stimulus that can produce legitimate opposition:
|
||||
|
||||
* **1050 load reversals** — 7 sizes (±300 W … ±4000 W) × 5 write staggers, the
|
||||
serialised write path landing unit B's number up to four cycles after A's;
|
||||
* **840 flapping loads** — 7 periods (10 s … 600 s) × 4 amplitudes.
|
||||
|
||||
Every run is executed **twice**: once at a roster of two and once at a roster of
|
||||
one on the same stimulus. **The N=1 arm is the control**, and it is the reason
|
||||
this document can separate *"a property of the check that shipped"* from *"a
|
||||
property of the second inverter"* instead of asserting one and hoping.
|
||||
|
||||
Supervised caps are the shipped `max_w` (2000 W per unit), so the site rail is
|
||||
2000 W at N=1 and 4000 W at N=2 — `Controller.site_max_w`, the roster sum.
|
||||
|
||||
### Reproducing it
|
||||
|
||||
The harness is **not committed here**, for the reason SAFETY-31's was not: it
|
||||
imports `plantsim` and `frame_check`, which live in the other repository and are
|
||||
not present in CI. What it does is small enough to restate: build two
|
||||
`plantsim.Inverter`s from `INVERTER_A` / `INVERTER_B`, close the loop with the
|
||||
add-on's own `compute()` and `arbiter.allocate_record()`, put each share on its
|
||||
own wire through `Inverter.command()`, advance `Site.settle()` one control cycle,
|
||||
and record `(standing command, inv.reg(0x0518))` per unit and
|
||||
`(Σ standing, site.grid)` for the site. Then, for each candidate threshold, the
|
||||
**longest run of consecutive cycles** on which the shipped `disagrees()` is true —
|
||||
not a count of true samples, because the watchdog's window is cleared by any
|
||||
disagreeing sample. Point it at a checkout with `GOODWE_ADDON_REPO`.
|
||||
⚠️ MUTATION.md's note applies: those harnesses write `__pycache__` into **both**
|
||||
trees.
|
||||
|
||||
### A. PER-UNIT — a unit's standing command vs its own 0x0518 power, N=2
|
||||
|
||||
| threshold | worst continuous, reversals | worst continuous, flapping | runs crossing (of 1890) |
|
||||
|---:|---:|---:|---:|
|
||||
| 50 W | 25.0 s | 20.0 s | 962 |
|
||||
| 100 W | 20.0 s | 15.0 s | 511 |
|
||||
| 150 W | 15.0 s | 15.0 s | 379 |
|
||||
| 200 W | 10.0 s | 15.0 s | 258 |
|
||||
| **250 W** | **10.0 s** | **10.0 s** | **194** |
|
||||
| 300 W | 10.0 s | 10.0 s | 124 |
|
||||
| 500 W | 5.0 s | 5.0 s | 37 |
|
||||
| 700 W | 5.0 s | 5.0 s | 16 |
|
||||
| 1000 W | 0.0 s | 0.0 s | 0 |
|
||||
|
||||
Largest opposed magnitude anywhere in the 1890 runs: **875 W**.
|
||||
|
||||
**The curve is flat, and that is the finding that decided the shape of this
|
||||
pair.** Unlike the site comparison — where the meter is driven by the LOAD and a
|
||||
flapping load can hold it opposed for minutes — a unit's own power **chases its
|
||||
own command** through a bounded ramp and a first-order lag, so the opposition can
|
||||
only last as long as the crossing does. Dropping the threshold from 300 W to
|
||||
50 W buys 15 s of extra transient and nothing else. **So the work is done by the
|
||||
window, and the threshold is put where the control law already draws its line.**
|
||||
|
||||
#### `unit_sign_disagree_w: 250` — schema `int(50,5000)`
|
||||
|
||||
`saturation_w / 2`. The check gates on **both** sides being over `min_w`, and the
|
||||
two are **opposed**, so the smallest command-versus-power gap it can ever see is
|
||||
`2 × min_w`. At 250 W that is exactly the 500 W at which `compute()`'s own
|
||||
anti-windup test already concludes the inverter is not following. **This watchdog
|
||||
therefore cannot fire on a divergence the shipped control law itself calls
|
||||
ordinary tracking**, and the two guards meet at a number.
|
||||
|
||||
Rejected: a threshold above the observed 875 W maximum, which would gate nothing
|
||||
legitimate in — and would also be blind to a unit reversing a 900 W share.
|
||||
|
||||
#### `unit_sign_disagree_s: 85` — schema `int(30,1800)`
|
||||
|
||||
Three bounds, and the value clears all three.
|
||||
|
||||
* **lower, from the rig — 10.0 s.** Two control cycles, the worst continuous
|
||||
legitimate opposition above 250 W across all 1890 runs. It is a reversing site
|
||||
whose second write lands a cycle after the first, both units then slewing
|
||||
through zero behind a 10 s lag. Nothing is wrong.
|
||||
* **lower, from the firmware — 30 s (`inverter.LINK_STALE_S`).** A unit not
|
||||
executing its share for less than the firmware's own veto window is a *link*
|
||||
fault the add-on already answers by dropping the unit from the split. Firing
|
||||
inside that window would raise a second, louder alarm about a state already
|
||||
being handled — the SAFETY-15/SAFETY-19 failure exactly.
|
||||
* **upper, from SAFETY-02 itself — 180 s, the site hold.** A unit that is not
|
||||
doing what it was told must not be parked *later* than the site would be
|
||||
parked for the same watts, and this conclusion needs nothing to net out: it is
|
||||
complete on the first cycle it appears.
|
||||
|
||||
**85 s** is seventeen control cycles: **8.5× the worst legitimate episode**,
|
||||
**2.8× the firmware veto**, and **under half** the site hold. Deliberately not
|
||||
60, 75, 90, 120 or 180.
|
||||
|
||||
### B / C. SITE — Σ standing commands vs the meter, at BOTH rosters
|
||||
|
||||
**Load-reversal family** (1050 runs each), worst continuous legitimate opposition:
|
||||
|
||||
| threshold | **N=2** | **N=1 (control)** | ratio |
|
||||
|---:|---:|---:|---:|
|
||||
| 100 W | 335.0 s | 175.0 s | 1.91× |
|
||||
| 200 W | 260.0 s | 120.0 s | 2.17× |
|
||||
| **300 W** | **215.0 s** | **110.0 s** | **1.95×** |
|
||||
| 500 W | 155.0 s | 90.0 s | 1.72× |
|
||||
| 700 W | 130.0 s | 70.0 s | 1.86× |
|
||||
| 1000 W | 85.0 s | 35.0 s | 2.43× |
|
||||
|
||||
**The second inverter roughly DOUBLES the worst legitimate crossing, and at the
|
||||
shipped 300 W threshold it takes it from 110 s — comfortably inside the 180 s
|
||||
hold — to 215 s, which is outside it.**
|
||||
|
||||
The mechanism is not mysterious and is worth stating because it predicts the
|
||||
ratio: the transient the 180 s hold exists to reject is the loop crossing zero
|
||||
after a load reversal, and the command has to travel the whole **site rail** at
|
||||
`slew_w` per cycle. At N≥2 that rail is `Controller.site_max_w`, the roster sum,
|
||||
while `slew_w` is unchanged. The worst case is the corner of the config space
|
||||
where that takes longest — `gain: 0.05`, `slew_w: 50`, both **schema floors** —
|
||||
against a ±2200 W load reversal, which is an oven and a heat pump.
|
||||
|
||||
#### `site_sign_disagree_w: 300` — CARRIED, and here is the justification
|
||||
|
||||
The argument behind 300 W is about **noise**: *"near zero the sign is noise, and
|
||||
near zero is where a healthy loop LIVES"* — the deadband holds the command still
|
||||
while the meter wanders either side of `target_grid_w`. `deadband_w` is 15 W and
|
||||
there is one P1 whatever is behind it. **Nothing in that argument depends on the
|
||||
roster**, and the campaign agrees: the fraction of samples gated in at 300 W is
|
||||
within a few percent at both rosters. Carried, with a measurement behind the
|
||||
carry rather than an assumption.
|
||||
|
||||
#### `site_sign_disagree_s: 325` — NOT carried, and that is the point of the card
|
||||
|
||||
180 s is **inside** the 215 s the two-inverter campaign measures, at a
|
||||
configuration the schema accepts. Carrying it would have shipped a false trip on
|
||||
the check with the best record in the safety table — which is the exact failure
|
||||
this card was opened to prevent, arriving from the other direction.
|
||||
|
||||
**325 s** is 1.51× the measured worst. It is well inside the **900 s** quarter
|
||||
that bills the capacity tariff, and it is inside **every** episode the fault day
|
||||
contains: 2026-08-20's four clusters run 16, 30, 77 and 77 minutes, and its
|
||||
opposed runs reach 1750 s. What it costs is stated rather than hidden — about two
|
||||
and a half extra minutes of wrong-direction **site** power before the stop —
|
||||
and it is bought to remove a false trip a legal configuration produces.
|
||||
Deliberately not 300 or 360.
|
||||
|
||||
**Rejected alternative:** keep 180 s and raise the site threshold to 1000 W,
|
||||
where the worst is 85 s. It gives a better margin and a faster stop, and it is
|
||||
wrong: it would be raising a **noise** gate to reject a **transient**, which is
|
||||
what the window is for, and it would leave the site check blind to a 900 W
|
||||
whole-site reversal at a 4 kW site.
|
||||
|
||||
### A limitation this campaign found, which SAFETY-30 does not introduce and does not fix
|
||||
|
||||
The **flapping-load** family behaves completely differently for the SITE
|
||||
comparison, and the control arm is what makes it interpretable:
|
||||
|
||||
| threshold | **N=2** | **N=1 (control)** |
|
||||
|---:|---:|---:|
|
||||
| 300 W | 980.0 s | 1000.0 s |
|
||||
| 700 W | 975.0 s | 1000.0 s |
|
||||
| 1000 W | 950.0 s | 1000.0 s |
|
||||
|
||||
A square wave whose half period is about one control cycle opposes the command on
|
||||
**every** cycle: the command chases the previous half-cycle's meter while the
|
||||
meter has already reversed. **No window inside the billing quarter survives it and
|
||||
no threshold up to 1000 W does either — at EITHER roster.** The N=1 column is
|
||||
this document's whole reason for existing: this is a property of comparing a
|
||||
lagged command against a meter, and it has nothing to do with the second
|
||||
inverter.
|
||||
|
||||
It is not acted on here, in order of weight: it is **identical at the roster this
|
||||
add-on ships**, so acting on it would be changing a live safety path on evidence
|
||||
that has nothing to do with this card; a ~6 kW square wave at 0.1 Hz sustained
|
||||
for a quarter of an hour is not a house (the captured healthy day's longest
|
||||
opposed run is **30 s**); and the fix is not a number — it wants the detector to
|
||||
notice that the disagreement is **alternating**, which is a different check.
|
||||
**It is a card, and this section is its evidence.**
|
||||
|
||||
### D. The fault arm — because a survey of healthy data is not a derivation
|
||||
|
||||
210 runs with inverter B executing the **negation** of its share throughout,
|
||||
sibling faithful, meter left to net:
|
||||
|
||||
| threshold | longest run the per-unit check detects | runs the SITE check also sees |
|
||||
|---:|---:|---:|
|
||||
| 250 W | 890.0 s | 210 / 210 |
|
||||
| 300 W | 890.0 s | 180 / 210 |
|
||||
| 700 W | 885.0 s | 112 / 210 |
|
||||
| 1000 W | 885.0 s | 60 / 210 |
|
||||
| 1500 W | 880.0 s | 45 / 210 |
|
||||
| 2000 W | 0.0 s | 39 / 210 |
|
||||
|
||||
At the shipped 250 W the fault is detected continuously for the whole run in
|
||||
every one of the 210 — an 85 s hold has ten times the evidence it needs. The
|
||||
right-hand column is the honest half: on a *reversing* stimulus the site
|
||||
comparison often does see something too, because the reversal is large enough to
|
||||
move the meter. **The case it cannot see is the steady one**, and that is the
|
||||
fixture `test_watchdog.py` part 4 runs: the shipped comparison is false on
|
||||
**0 of 14** cycles while the per-unit check convicts B on every one.
|
||||
|
||||
## 4. Inverter B does not exist
|
||||
|
||||
Every two-inverter figure in §3 was produced with **inverter A's ramp and lag
|
||||
copied onto B** (`plantsim.INVERTER_B`, `measured=False`); its 3000 W rating,
|
||||
where this repository's fixtures use one, is a **hypothesis marked as one**.
|
||||
[[SPIKE-04]] measures the real ones and is the revisit trigger for all four
|
||||
numbers — not a reason to move any of them now.
|
||||
|
||||
Which figures depend on it, stated so nobody has to work it out:
|
||||
|
||||
* **`unit_sign_disagree_s: 85`** — most. Its lower bound is the 10.0 s crossing,
|
||||
which is a direct function of B's ramp and lag. A slower second unit lengthens
|
||||
it; the 8.5× is what buys headroom for that.
|
||||
* **`site_sign_disagree_s: 325`** — yes, but less directly. Its 215 s is
|
||||
dominated by the **rail** and by `slew_w`, which are configuration, not
|
||||
hardware; B's dynamics move it at the margin.
|
||||
* **`unit_sign_disagree_w: 250`** — **no.** It is `saturation_w / 2`, read off
|
||||
the add-on's own control law. The rig only confirms that nothing legitimate
|
||||
sits over it for long.
|
||||
* **`site_sign_disagree_w: 300`** — **no.** It is the meter's noise floor and the
|
||||
deadband, neither of which is a property of any inverter.
|
||||
|
||||
## 5. Mutation ledger
|
||||
|
||||
Every run on a **freshly copied tree of its own, no `__pycache__`, mounted
|
||||
`:ro`** into the CI image — the structural immunity MUTATION.md records. ⚠️ The
|
||||
first battery used ONE shared directory rebuilt between mutations and reported a
|
||||
**RED baseline**; a container mounted it mid-copy and read a missing
|
||||
`config.yaml` as a failing check. That whole run was discarded: MUTATION.md's
|
||||
rule is that a run which could have been racing is not a result, and a battery
|
||||
whose baseline is not green establishes nothing. The harness now copies a
|
||||
directory per mutation and **refuses to report anything if the baseline is not
|
||||
green**.
|
||||
|
||||
Byte deltas measured, not estimated; the `+0 B` ones are marked, since a
|
||||
size-preserving edit is what TEST-15 turned into a false survivor once already.
|
||||
|
||||
| # | file | mutation | Δ | result |
|
||||
|---|---|---|---|---|
|
||||
| M1 | `main.py` | the per-unit comparison put back to `self.grid` at every roster | −30 B | **RED** — `test_watchdog.py`. This is the card |
|
||||
| M2 | `main.py` | the per-unit comparison forced to `inv.batt` at N=1 too | −31 B | **RED** — AC 8 |
|
||||
| M3 | `main.py` | the site half never evaluated | −6 B | **RED** — AC 3 |
|
||||
| **M4** | `main.py` | **the site half armed at N=1 as well** | **+0 B** | **SURVIVOR on the first battery — GAP CLOSED**, then RED. See below |
|
||||
| M5 | `main.py` | the `sign_site` claim never filed | −6 B | **RED** — `test_watchdog.py`. ⚠️ `test_peakguard.py` stayed **GREEN**, correctly: 10f's AST scan pins which sources CAN be filed and the append is still written; whether it is REACHED is a dynamic question no fixture there gets to |
|
||||
| M6 | `main.py` | the site latch not persisted to the store | −58 B | **RED** — the flat-keys and restart checks |
|
||||
| M7 | `main.py` | the operator clear leaves the site latch set | −42 B | **RED** — the clear check |
|
||||
| M8 | `watchdog.py` | `arm()` clears `disagree_since` | +35 B | **RED** — "re-armed on every one of 38 cycles still trips" |
|
||||
| M9 | `watchdog.py` | the reason hard-codes "a meter reading" again | +1 B | **RED** — `test_watchdog.py`. `test_inverter.py` stayed **GREEN**; its part-3 row reads the noun off `sign_wd.against` rather than out of the reason string, so the two checks bite in different places |
|
||||
| M10 | `watchdog.py` | `unit_sign_disagree_w` 250 → 300 | **+0 B** | **RED** — the `saturation_w / 2` pin and the CFG-03 pin |
|
||||
| M11 | `watchdog.py` | `site_sign_disagree_s` 325 → 180, i.e. **the number carried** | **+0 B** | **RED** — the measured-215 s check and the CFG-03 pin |
|
||||
| M12 | `arbiter.py` | `sign_site` scoped `SCOPE_UNIT` | **+0 B** | **RED** — `test_arbiter.py` **and** `test_peakguard.py` |
|
||||
| M13 | `validate.py` | the `unit_sign_disagree_w` rule removed | −126 B | **RED** — `test_validate.py` |
|
||||
| **M14** | `main.py` | **`arm()` handed `self.sign_cfg` at EVERY roster** — the WIRING, not the values | −31 B | **SURVIVOR at review — GAP CLOSED**, then RED. See below |
|
||||
| M15 | `main.py` | per-unit `arm()` given the right `min_w` and the SHIPPED hold — a HOLD-ONLY mis-wire | +78 B | **RED** — the same wiring pin |
|
||||
| M16 | `main.py` | per-unit `arm()` given the right `min_w` and the SITE hold — hold-only again, and behaviour-preserving | +83 B | **RED** — the wiring pin, and the ONLY red in `test_watchdog.py` |
|
||||
|
||||
### M4 is recorded as a survivor because it was one
|
||||
|
||||
The check it should have gone red on read:
|
||||
|
||||
```python
|
||||
not _c1s.site_sign_wd.tripped and _c1s.site_sign_wd.disagree_since is None
|
||||
```
|
||||
|
||||
Arming the site detector at a roster of one left that **green**, and the reason
|
||||
is worth reading because the check looked airtight. In the N=1 fixture the unit
|
||||
detector trips first at its 1 s hold and parks the inverter; the site's standing
|
||||
command is then **0 W**, so the site predicate is false, its window is never
|
||||
opened, and `disagree_since is None` is true *whether or not the detector was
|
||||
evaluated at all*. **The assertion ran, the sentence was true, and the data
|
||||
could not reach the failure it named** — MUTATION.md's third failure mode,
|
||||
inside the check written to prevent it.
|
||||
|
||||
Replaced with a **call counter installed on the object** before the run: twelve
|
||||
cycles, zero calls, printed. A counter can only be zero for one reason. The
|
||||
mutation was re-run against it and is red; the run that found it was discarded
|
||||
along with its tree, so this is a result and not an artefact.
|
||||
|
||||
### M14: the VALUES were pinned and the WIRING was not
|
||||
|
||||
M10 and M11 mutate the numbers in `watchdog.SIGN_OPTION_DEFAULTS` and both are
|
||||
red through the config pins. Neither of them touches the line that DELIVERS
|
||||
those numbers to a detector:
|
||||
|
||||
```python
|
||||
inv.sign_wd.arm(self.sign_cfg if one else self.unit_sign_cfg,
|
||||
AGAINST_METER if one else AGAINST_OWN_POWER)
|
||||
```
|
||||
|
||||
Drop the conditional — `arm(self.sign_cfg, ...)` — and every unit is armed with
|
||||
SAFETY-02's meter-facing pair instead of the re-derived per-unit one. At review
|
||||
that left **all 19 files green**. `grep -rn "sign_wd.cfg" test_*.py` found
|
||||
exactly one threshold assertion, and it is §7's N=1 arm — `(300.0, 1.0)` —
|
||||
which the mutation PRESERVES. Nothing anywhere read `inv.sign_wd.cfg` at a
|
||||
roster of two.
|
||||
|
||||
The behavioural checks in part 3 cannot close it and it is worth saying why: B
|
||||
is reversed at ~2000 W and every hold in that fixture is short, so B trips under
|
||||
either pair. **A fault big enough and long enough to trip under both thresholds
|
||||
is evidence about neither.**
|
||||
|
||||
What the survivor costs in the field is the whole product of §3: at
|
||||
`config.yaml`'s own defaults the per-unit check would run at `sign_disagree_s`
|
||||
**180 s instead of 85 s** — 2.1× slower to park a reversed inverter — and its
|
||||
gate would move from 250 W to 300 W, so a unit reversing a share between the two
|
||||
becomes invisible, while `SIGN_OPTION_DEFAULTS`, `config.yaml` and §3 all go on
|
||||
describing a pair the running code does not use. With CI green.
|
||||
|
||||
**Closed by a wiring pin in `test_watchdog.py` part 3**, on the real
|
||||
two-inverter Controller: every `inv.sign_wd.cfg` equals the per-unit pair,
|
||||
`site_sign_wd.cfg` equals the site pair, and each detector's `against` is its
|
||||
own instrument — all graded **against literals**, since `== self.unit_sign_cfg`
|
||||
cannot tell *the per-unit pair* from *whatever this Controller was handed*.
|
||||
|
||||
⚠️ **And the fixture had to be changed for that pin to mean anything.**
|
||||
`_sign_site` set `unit_sign_disagree_s: 1` **and** `site_sign_disagree_s: 1`
|
||||
**and** `sign_disagree_s: 1`, with two of the three magnitude gates at 300 W. A
|
||||
bare equality there discriminates on `min_w` alone: a mis-wiring that delivered
|
||||
the right magnitude with the wrong hold would compare EQUAL to the pair it was
|
||||
supposed to have. That is this document's own §5 lesson and MUTATION.md's third
|
||||
failure mode — a check comparing two things that happen to be equal cannot see
|
||||
the difference it names — reappearing inside the fix for it. The three pairs are
|
||||
now pairwise distinct **in both coordinates** (250 W / 1 s, 320 W / 2 s,
|
||||
300 W / 3 s), a PRECONDITION check asserts that distinctness so a later edit
|
||||
collapsing them goes red rather than quietly vacuous, and both pairs are
|
||||
**printed**. M15 and M16 exist to show the hold half actually bites: right
|
||||
magnitude, wrong hold, red both times — and M16, whose wrong hold still trips
|
||||
inside the drive, is red on the wiring pin and on **nothing else** in that file.
|
||||
|
||||
## 6. What this card does NOT close
|
||||
|
||||
* **The flapping-load blind spot in the SITE comparison.** §3, at length. Present
|
||||
identically at the shipped roster of one; wants an alternation test, not a
|
||||
number; a card of its own.
|
||||
* **A unit misbehaving while it is NOT loop-driven.** Gate 1 (`following`) is
|
||||
kept for the per-unit comparison, deliberately: the whole no-false-positive
|
||||
argument is built on it, and the saturation freeze already grades that window.
|
||||
So between the start of a maintenance cycle and its end, a unit reversing
|
||||
against its own command is the freeze's to notice. Widening it is a card with a
|
||||
rig campaign behind it, not an edit.
|
||||
* **A sign inversion downstream of this add-on** — in the firmware, on the wire,
|
||||
or in a future driver. Unchanged: our view stays self-consistent and both
|
||||
comparisons stay silent. That is the witness's problem and it always was.
|
||||
* **A false-alarm interaction with SAFETY-31 that nobody has to think about.**
|
||||
They overlap in one scenario and both fire in it. That is correct — they
|
||||
conclude different things — but an operator will see two alarms for one event.
|
||||
Whether the banner should say so in one sentence is a UI card.
|
||||
@@ -0,0 +1,316 @@
|
||||
# SAFETY-31 — what "acted on" means for circulating power, and what it cannot mean
|
||||
|
||||
**Status: DECIDED 2026-09-04.** The trip **stops the site**: a `SET 0 W` claim
|
||||
at `P_SAFETY` on the **site** actuator, latched, persisted, and re-announced
|
||||
after a restart. This document records why that is an action rather than
|
||||
theatre, given that [[HW-01]] established a wedged inverter cannot be commanded
|
||||
at all — and it records the numbers the threshold and the window were read off,
|
||||
because "establish the window from the rig, do not pick a round number" is an
|
||||
acceptance criterion and a number without its measurement is a guess.
|
||||
|
||||
Filed with SAFETY-31. Card `6a99e0022b6a6c8ca15dbe3e`.
|
||||
|
||||
---
|
||||
|
||||
## 0. The two halves, and which one this card built
|
||||
|
||||
Half of this card was already shipped, and it is not the half below.
|
||||
|
||||
| | **ALLOC-01, AC 7 — the COMMAND half** | **SAFETY-31 — the MEASUREMENT half** |
|
||||
|---|---|---|
|
||||
| what it is | `allocator.REFUSE_SIGN` | `circulation.circulating_w()` + `CirculationWatchdog` |
|
||||
| what it sees | the shares the allocator is about to hand out | each inverter's **own measured power** (`Inverter.batt`, register 0x0518) |
|
||||
| what it does | **refuses** the allocation, names both units, returns no shares | **stops the site**, latches, alarms durably |
|
||||
| what it covers | circulating power the allocator would have **commanded** | circulating power **nobody commanded** |
|
||||
| graded by | `test_alloc.py` part 6 | `test_watchdog.py`, the SAFETY-31 section |
|
||||
|
||||
**They are complements, not duplicates.** The gate refuses an allocation before
|
||||
it is written and cannot see one millisecond past that. This card reads the
|
||||
hardware and does not care what was written. Neither replaces the other, and
|
||||
**a sensor built on the allocation record would collapse the second into the
|
||||
first and detect nothing** — see §2.
|
||||
|
||||
## 1. What "acted on" means
|
||||
|
||||
> **The trip files `Claim.set("circulation", P_SAFETY, 0.0)` on the SITE
|
||||
> actuator. Every inverter is commanded 0 W and held there until an operator
|
||||
> starts control again.**
|
||||
|
||||
### The objection, which is correct
|
||||
|
||||
[[HW-01]] is on the record: on 2026-09-02 the comms subsystem failed and the
|
||||
power stage went on executing its last instruction for **6 h 25 m**, through
|
||||
every command this add-on sent it. If the cause of the circulation is a unit
|
||||
that has stopped listening, **a command is not a remedy**, and shipping one as
|
||||
though it were is theatre.
|
||||
|
||||
### The answer
|
||||
|
||||
**A circulating loop needs two participants.** In every cause on this card's
|
||||
list — a unit ignoring its share, a unit lagging it, a stale share still being
|
||||
executed, a maintenance or [[SAFETY-25]] pin holding one unit while the loop
|
||||
drives the other, or HW-01's wedged power stage — **exactly one participant is
|
||||
the unit that stopped listening, and the other one is this controller**,
|
||||
faithfully commanding the sibling to a share computed to sum with a number the
|
||||
wedged unit is not actually producing.
|
||||
|
||||
Stopping the commanding half does two things a notification cannot:
|
||||
|
||||
1. **It halves the loop.** The unit that *is* still listening stops being driven
|
||||
into the one that is not. That is real energy and real cycles off a real
|
||||
pack, and it needs no cooperation from the wedged unit to take effect.
|
||||
2. **It makes the residue visible — and this is the more important half.**
|
||||
Circulating power hides *because it nets to zero at the meter*. With this
|
||||
controller's contribution removed, whatever the wedged unit is still doing
|
||||
stops being cancelled and appears at P1 as a plain net flow, where
|
||||
SAFETY-02's sign watchdog, the peak guard and the capacity tariff can all see
|
||||
it. **The fault stops being invisible.**
|
||||
|
||||
Measured on the [[TEST-19]] rig, and this is the number that makes the case:
|
||||
in the card's own scenario — A at −3000 W, B at +3000 W, house load 0 W — the
|
||||
meter reads **+0 W** and the shipped `SignWatchdog`'s predicate is **false on
|
||||
every one of 30 cycles**, because it gates on `abs(grid_w) > 300` and the gate
|
||||
never opens.
|
||||
|
||||
### What it does not do, said plainly
|
||||
|
||||
**It does not stop the wedged inverter. Nothing this add-on can send will.** If
|
||||
the loop persists at the meter after this trip, the remaining actuator is a
|
||||
human at the isolator, and the notification says so in those words.
|
||||
|
||||
### Why the claim is SITE-scoped
|
||||
|
||||
`arbiter.CLAIM_SCOPE` classifies `circulation` as `SCOPE_SITE`, beside `loop`,
|
||||
`peak`, `arbitrage` and `safety`. The neighbouring `failsafe` entry looks like
|
||||
it and is not: SAFETY-02 has site-wide *evidence* and a per-unit *conclusion*,
|
||||
because it compares the meter against the command **this controller put on one
|
||||
actuator**.
|
||||
|
||||
Circulating power has no such conclusion available. It is
|
||||
`Σ|Bᵢ| − |ΣBᵢ|` — defined over the whole roster, **identically zero for any one
|
||||
unit** — and there is no fact of the matter about which of two opposing
|
||||
inverters is the offender: *a unit ignoring its share* and *a sibling faithfully
|
||||
executing a share computed to sum with it* produce **identical readings**.
|
||||
Filing this per-unit would require inventing an attribution the measurement
|
||||
cannot support, and would park one inverter while the other went on feeding the
|
||||
loop — quite possibly parking the only one still listening.
|
||||
|
||||
The same argument is why the latch is **flat** in the store (`circ_tripped`,
|
||||
`circ_reason`) and not namespaced like SAFETY-02's. One site, one latch.
|
||||
|
||||
## 2. Why the sensor is MEASURED, and why the cheap version is worthless
|
||||
|
||||
The obvious cheap version computes the same formula over `Allocation.shares`.
|
||||
It would be simpler, would never be `None`, and would be **worth nothing**, for
|
||||
two independent reasons:
|
||||
|
||||
1. **It cannot fire.** ALLOC-01's sign-coherence gate already refuses any
|
||||
allocation whose shares carry two signs. A record-derived sensor is therefore
|
||||
a sensor over a set that is **guaranteed sign-coherent**. It reads zero *by
|
||||
construction*, forever.
|
||||
2. **It is [[MUTATION.md]]'s third failure mode.** It could only ever confirm
|
||||
that the allocator agrees with itself — a check whose data cannot reach the
|
||||
failure it names.
|
||||
|
||||
Verified rather than argued. On the rig, with inverter B wedged on a stale
|
||||
discharge while PV drives the site to charge:
|
||||
|
||||
```
|
||||
S = -2500 W shares a = -1250 W b = -1250 W <- record: ok, ONE sign, sums to S
|
||||
MEASURED A = -1250 W B = +1000 W <- hardware
|
||||
sensor over the RECORD : 0 W
|
||||
sensor over MEASURED power : 2000 W -> trips at 190 s
|
||||
```
|
||||
|
||||
And the card's own headline scenario, driven on the same rig — A at −3000 W,
|
||||
B at +3000 W, house load 0 W:
|
||||
|
||||
```
|
||||
METER (P1) : +0 W <- the site looks IDLE
|
||||
sensor over MEASURED power : 6000 W -> trips at 100 s
|
||||
SAFETY-02 SignWatchdog : predicate false on 30 of 30 cycles
|
||||
```
|
||||
|
||||
The same pair is asserted in `test_watchdog.py` **with the precondition written
|
||||
as its own check and printed**, per MUTATION.md's rule, and mutation **M10**
|
||||
(the property rewritten to read `self.allocation.shares`) takes it **red**.
|
||||
|
||||
## 3. The numbers, and where they come from
|
||||
|
||||
Both were read off a curve produced on `admin/goodwe`'s `sim/` two-master rig,
|
||||
used read-only: the add-on's own `compute()`, its own `allocator.plan()` and its
|
||||
own `circulating_w()`, driving `plantsim.Plant` through the firmware's own
|
||||
encoder, with the sensor input taken from each unit's holding register 0x0518.
|
||||
|
||||
**924 closed-loop runs in which nothing is faulty** — every unit executes the
|
||||
share it was given — over both families of stimulus that can produce legitimate
|
||||
opposition (7 reversals × 5 write staggers, and 7 flap periods × 4 amplitudes),
|
||||
each swept across the **whole range `config.yaml` accepts** for the two settings
|
||||
that decide how fast the site can turn around: `gain` `float(0.05,1.0)` and
|
||||
`slew_w` `int(50,5000)`.
|
||||
|
||||
### Reproducing it
|
||||
|
||||
The rig lives in `admin/goodwe` (`sim/`) and was used **read-only**; the harness
|
||||
is not committed here because it imports that repo's `plantsim`/`frame_check`,
|
||||
which are not present in this one or in CI. What it does is small enough to
|
||||
restate: build `Site([Inverter.from_spec("A", INVERTER_A),
|
||||
Inverter.from_spec("B", INVERTER_B)])`, close the loop with the add-on's own
|
||||
`compute()` and `allocator.plan()`, put each share on its unit's wire through
|
||||
`Inverter.command()` (which goes out through the firmware's real encoder), and
|
||||
read the sensor from `inv.reg(0x0518)` — **the same register the live add-on's
|
||||
`batt_entity` binds**, so the input is the one the shipped code gets. Point it
|
||||
at a checkout with `GOODWE_ADDON_REPO`. ⚠️ MUTATION.md's note applies: those
|
||||
harnesses write `__pycache__` into **both** trees, so purge both by hand before
|
||||
grading a mutation through one.
|
||||
|
||||
Every figure below was re-run against the final shipped `CirculationConfig`
|
||||
(`min_w=700`, `hold_s=75`) rather than against the draft values they were first
|
||||
measured at.
|
||||
|
||||
### Worst CONTINUOUS legitimate opposition, by threshold
|
||||
|
||||
| threshold | worst continuous | runs that ever cross it |
|
||||
|---:|---:|---:|
|
||||
| 100 W | **505.0 s** | 281 / 924 |
|
||||
| 200 W | 445.0 s | 174 / 924 |
|
||||
| 250 W | 40.0 s | 132 / 924 |
|
||||
| 300 W | 10.0 s | 115 / 924 |
|
||||
| **400 W** | **5.0 s** | 74 / 924 |
|
||||
| 700 W | 5.0 s | 33 / 924 |
|
||||
| 1000 W | 5.0 s | 16 / 924 |
|
||||
| 1700 W | 0.0 s | 0 / 924 |
|
||||
|
||||
****With the shipped `min_w=700 W` and `hold_s=75 s`, 0 of those 924 runs trip.**
|
||||
|
||||
The knee is at 400 W and it is sharp.** Below ~250 W a flapping load holds the
|
||||
sensor above the threshold for *minutes* at a time, and no window shorter than
|
||||
the 900 s billing quarter could tell that from a fault. At 400 W and above the
|
||||
worst legitimate episode collapses to **5.0 s — one control cycle — and stays
|
||||
there**. The worst peak on any legitimate run is **1700 W**.
|
||||
|
||||
That 5.0 s is the serialised write path doing exactly what it should: on a
|
||||
reversing cycle inverter B's new number lands up to a whole control cycle after
|
||||
A's, both then slew through zero at 800 W/s behind a 10 s lag, and **between the
|
||||
two zero crossings they genuinely oppose**. Nothing is wrong. A guard that
|
||||
tripped on it would be the fourth false-alarm generator of the week, and this
|
||||
project's doctrine on crying wolf is explicit ([[SAFETY-15]], [[SAFETY-19]]).
|
||||
|
||||
### `circulation_w: 700` — schema floor `400`
|
||||
|
||||
`700` is **1.75× the measured knee**. The headroom is bought for one named
|
||||
reason: **inverter B does not physically exist.** Its ramp and lag in the rig
|
||||
are inverter A's, *copied*, carrying `measured=False`; [[SPIKE-04]] measures the
|
||||
real ones. A slower or faster second unit moves the transient's shape, and the
|
||||
margin above the knee is what absorbs that without re-opening this card.
|
||||
**Revisit when SPIKE-04 lands, not before.**
|
||||
|
||||
The **schema floor is the knee itself**, 400 W, so a legally configured install
|
||||
cannot land in the 445–505 s regime. What the threshold costs: a circulating
|
||||
loop smaller than 350 W per unit is not reported, which is deliberate — at that
|
||||
scale the round-trip loss is a few watts.
|
||||
|
||||
### `circulation_hold_s: 75` — schema range `30..900`
|
||||
|
||||
Three bounds, and the value clears all three:
|
||||
|
||||
* **lower, from the rig — 5.0 s.** The worst continuous legitimate opposition
|
||||
above 700 W across all 924 runs.
|
||||
* **lower, from the firmware — 30 s (`inverter.LINK_STALE_S`).** A unit still
|
||||
executing a stale share for less than the firmware's own veto window is a
|
||||
*link* fault, and the add-on already answers it: liveness drops the unit and
|
||||
the survivors carry its share, with the record saying so. Firing inside that
|
||||
window would raise a second, louder alarm about a state already being handled.
|
||||
* **upper, from the bill — 900 s**, the quarter that sets the capacity tariff.
|
||||
|
||||
**75 s** is fifteen control cycles: **15× the worst legitimate episode**, **2.5×
|
||||
the firmware veto**, and **12× inside the quarter**. It is deliberately not 60
|
||||
or 120 — a round number here would be a guess wearing a measurement's clothes,
|
||||
and a check in `test_watchdog.py` asserts it is none of the values a guess
|
||||
lands on.
|
||||
|
||||
## 4. Why the window cannot be defeated the way SAFETY-02's was
|
||||
|
||||
`allocator.py` records the measurement that makes SAFETY-02 blind to the
|
||||
broadcast fight: the sign disagreement **flips on alternate ticks**, so
|
||||
`disagree_since` is cleared between every pair of them and the 180 s hold never
|
||||
accumulates.
|
||||
|
||||
Circulating power cannot do that. It is a **magnitude**, non-negative by
|
||||
construction, and a sustained loop holds it high on *every* cycle rather than
|
||||
every other one. An oscillation that genuinely alternated between opposing and
|
||||
agreeing is not a circulating loop and should not be reported as one — which is
|
||||
exactly the flapping-load case in §3, and it is why the window clears.
|
||||
|
||||
## 5. SAFETY-34: the latch is not the alarm
|
||||
|
||||
`persistent_notification` is **in memory**. Home Assistant restarts and the card
|
||||
is gone while the fault runs on — which is precisely how the 2026-09-02 outage
|
||||
went unseen for **6 h 25 m with the detector correct throughout**.
|
||||
|
||||
So the durable half and the visible half are joined, and the join is
|
||||
`Controller._circ_announced`: a **per-process** flag, deliberately *not*
|
||||
persisted. The latch in `/data/state.json` says *"this site is tripped"*; the
|
||||
flag says *"this process has put that in front of a human"*. A restart clears
|
||||
the flag and keeps the latch, so **the notification is re-raised on the first
|
||||
cycle after every start** — which is the first cycle after a Home Assistant
|
||||
restart, because the add-on restarts with it.
|
||||
|
||||
**One code path serves both** the fresh trip and the restart, on purpose: two
|
||||
paths would be two chances for the restart one to rot unnoticed, and the restart
|
||||
one is the case nobody exercises by hand. Mutations **M13** (flag initialised
|
||||
from the latch) and **M18** (the call removed) both take it red.
|
||||
|
||||
## 6. Mutation ledger
|
||||
|
||||
Every run on a **freshly copied tree with no `__pycache__`, mounted `:ro`** into
|
||||
the CI image — the structural immunity MUTATION.md records for CI and for
|
||||
SAFETY-25 — so no stale `.pyc` could exist to be read. Byte deltas recorded;
|
||||
**three are `+0 B`, the risky delta, and are marked**.
|
||||
|
||||
| # | file | mutation | Δ | result |
|
||||
|---|---|---|---|---|
|
||||
| M1 | `circulation.py` | `sum(abs(v))` → `sum(v)` in the sensor | −5 B | **RED** — the 6000 W, 2000 W and three-unit checks |
|
||||
| M2 | `circulation.py` | N≤1 returns `None` instead of `0.0` | +1 B | **RED** — AC 5's nine-reading sweep |
|
||||
| M3 | `circulation.py` | a missing reading at N≥2 returns `0.0` | −1 B | **RED** — "health from an absence" |
|
||||
| M4 | `circulation.py` | drop `max(0.0, ...)` | — | **EQUIVALENT, not run as a claim.** For a same-sign roster the two sums accumulate the same magnitudes in the same order and are bit-identical; 700 000 random rosters produced no negative. Argued at the line and in the check's own text. |
|
||||
| M5 | `circulation.py` | threshold `<=` → `<` | −1 B | **RED** — "exactly 700 W forever does not trip" |
|
||||
| M6 | `circulation.py` | window `<` → `<=` | +1 B | **RED** — "trips at 75 s, not before" |
|
||||
| M7 | `circulation.py` | the window removed entirely | −85 B | **RED** — both slew-transient checks |
|
||||
| M8 | `circulation.py` | `None` no longer clears the window | +34 B | **RED** — the stale-reading gap check |
|
||||
| M9 | `circulation.py` | the latch removed | −123 B | **RED** — "restored as tripped stays tripped" |
|
||||
| **M10** | `main.py` | **the sensor derived from `self.allocation.shares`** | +60 B | **RED** — AC 2's headline check. This is the card. |
|
||||
| M11 | `main.py` | the `circulation` claim never filed | −235 B | **RED** — `test_watchdog.py` **and** `test_peakguard.py` 10f/10g |
|
||||
| M12 | `main.py` | the latch not persisted to the store | −112 B | **RED** — all three durability checks |
|
||||
| M13 | `main.py` | `_circ_announced` initialised from the latch | +21 B | **RED** — SAFETY-34's re-raise |
|
||||
| M14 | `main.py` | the operator clear leaves `_circ_announced` set | −45 B | **RED** — "the next trip would raise nothing" |
|
||||
| M15 | `arbiter.py` | `circulation` scoped `SCOPE_UNIT` | **+0 B** | **RED** — `test_arbiter.py` ×3 and `test_peakguard.py` ×3 |
|
||||
| M16 | `config.yaml` | schema floor `400` → `100` | **+0 B** | **RED** — the measured-knee check |
|
||||
| M17 | `circulation.py` | default `700` → `500` | **+0 B** | **RED** — the CFG-03 pin and the not-a-round-number check |
|
||||
| M18 | `main.py` | `await self.check_circulating()` removed | −39 B | **RED** — all four notification checks |
|
||||
| M19 | `main.py` | publish `round(x or 0.0)` instead of `None` | −68 B | **survivor on the first battery — GAP CLOSED**, then RED |
|
||||
|
||||
**M19 is recorded as a survivor because it was one.** The first battery found no
|
||||
check grading what `publish()` does when a per-unit reading is missing, so
|
||||
turning *"I do not know"* into *"0 W"* on the one surface an operator actually
|
||||
watches went unnoticed — the sensor's own `None` rule, defeated one layer out.
|
||||
A check was added and the mutation re-run; it is red now. The run that found it
|
||||
was purged, so it is a result and not an artefact.
|
||||
|
||||
## 7. What this card does NOT close
|
||||
|
||||
* **Inverter B's ramp and lag are placeholders.** Every transient number in §3
|
||||
was produced with inverter A's parameters copied onto B (`measured=False`).
|
||||
SPIKE-04 measures the real ones and is the revisit trigger for the 1.75×
|
||||
margin. **Do not present any figure here as a measurement of inverter B.**
|
||||
* **A wedged inverter still cannot be stopped by this add-on.** §1 says so; the
|
||||
notification says so; there is no software fix and this card does not pretend
|
||||
to one.
|
||||
* **A loop below ~350 W per unit is not reported.** Deliberate, §3.
|
||||
* **The saturation freeze fires under a wedged unit and leaves a standing grid
|
||||
error.** Observed on the rig while producing §2's numbers: with B wedged, the
|
||||
loop's anti-windup test compares a site target against a measured site power
|
||||
that cannot track it, freezes the integrator and leaves the meter parked at
|
||||
−3750 W. Nothing alarms on that today — a freeze is an ordinary control action
|
||||
by design. It is a real finding, it is **not** in scope here, and it wants a
|
||||
card of its own.
|
||||
+203
-4
@@ -55,6 +55,82 @@ Use the ESP32's readings rather than the inverter's cloud or dongle sensors:
|
||||
those serve cached values, and a stale reading here ends the maintenance charge
|
||||
phase having charged nothing.
|
||||
|
||||
### More than one inverter (`inverters`)
|
||||
|
||||
The six keys above describe **one** inverter, and if that is your site there is
|
||||
nothing to do here — `inverters` ships empty and empty means *"the flat keys
|
||||
above describe the one inverter"*. **An install that upgrades into 0.6.0 reads
|
||||
identically to before: same entities, same rating, same behaviour, no operator
|
||||
action.**
|
||||
|
||||
To run two, declare them. Each entry names its own actuator, its own rating and
|
||||
its own sensors:
|
||||
|
||||
```yaml
|
||||
setpoint_entity: "" # ⚠️ must be cleared — see below
|
||||
inverters:
|
||||
- name: inverter-a
|
||||
setpoint_entity: number.goodwe_a_setpoint_w
|
||||
soc_entity: sensor.goodwe_a_soc
|
||||
batt_entity: sensor.goodwe_a_battery_power
|
||||
max_w: 5000
|
||||
- name: inverter-b
|
||||
setpoint_entity: number.goodwe_b_setpoint_w
|
||||
soc_entity: sensor.goodwe_b_soc
|
||||
batt_entity: sensor.goodwe_b_battery_power
|
||||
max_w: 3000
|
||||
```
|
||||
|
||||
| per-entry key | required | meaning |
|
||||
|---|---|---|
|
||||
| `name` | yes | Short identifier. It namespaces this unit's SAFETY-02 latch, heartbeat and write bookkeeping in the add-on's state file, so **two units may not share one** |
|
||||
| `setpoint_entity` | yes | This inverter's own ESPHome `number.*_goodwe_setpoint_w` |
|
||||
| `max_w` | yes | The supervised cap on what may be written to **this** inverter. The site's ceiling is the **sum** |
|
||||
| `soc_entity` | | This pack's state of charge |
|
||||
| `batt_entity` | | This unit's battery power, `+` = discharging |
|
||||
| `batt_invert` | | Flip if needed |
|
||||
|
||||
⚠️ **Nothing is inherited.** An entry that leaves out `soc_entity` has **no SoC
|
||||
sensor** — it does *not* fall back to the flat one. That is deliberate: every
|
||||
per-device value became per-instance in 0.5.x precisely so that no inverter is
|
||||
ever graded against a sibling's numbers, and a silent fallback would rebuild
|
||||
that in YAML. `name`, `setpoint_entity` and `max_w` are required of every entry
|
||||
for the same reason: there is no rating to borrow.
|
||||
|
||||
⚠️ **Clear the flat `setpoint_entity` when you declare a roster,** or the add-on
|
||||
refuses to start and says so. It is the single-inverter form and it is not read
|
||||
once a roster exists, so leaving it set means one of two things: it names an
|
||||
entity an entry also names — two writers on one actuator, which specs §1.5 makes
|
||||
a non-goal and the add-on refuses outright — or it names a different one, which
|
||||
nothing would ever write, leaving a site running quietly smaller than its
|
||||
configuration reads. `soc_entity`, `batt_entity`, `batt_invert` and `max_w`
|
||||
cannot be blanked (the schema gives them no empty value); they are simply not
|
||||
read, and the add-on writes one line into its action log at every start saying
|
||||
so.
|
||||
|
||||
⚠️ **Two inverters naming the same `setpoint_entity` are refused,** whichever
|
||||
keys they are declared under and whatever the capitalisation. Two independent
|
||||
setpoints on one inverter is the arbitration problem this add-on exists not to
|
||||
have.
|
||||
|
||||
⚠️ **Update the add-on first, then add the roster.** Home Assistant validates the
|
||||
options you save against the schema of the version that is *installed*, so
|
||||
`inverters` cannot be set before 0.6.0 is installed. The order is: update, then
|
||||
configure.
|
||||
|
||||
⚠️ **Going the other way — downgrading with a roster configured — is recoverable
|
||||
but NOT uneventful, and the add-on will not start until you refill a field.**
|
||||
The *schema* side is fine: the older version's schema has no `inverters` key, so
|
||||
it drops the key with a warning rather than refusing the whole blob (measured —
|
||||
`DECISIONS/CFG-04-inverter-roster.md` §E). The *add-on* side is not. Rule 9(e)
|
||||
requires the flat `setpoint_entity` be **cleared** when a roster is declared, so
|
||||
a config that downgrades cleanly is by construction a config whose flat
|
||||
actuator is blank — and the older version has nothing else to write to. It stops
|
||||
at startup validation with a refusal naming `setpoint_entity`, which is loud and
|
||||
in the log rather than silent, but it is an outage until someone puts the
|
||||
single-inverter entity back in that field. **Before downgrading, write down the
|
||||
`setpoint_entity` of the unit you want to keep running.**
|
||||
|
||||
### P1 meter ingestion
|
||||
|
||||
`meter_entity` above expects one signed sensor, which usually means a template
|
||||
@@ -272,7 +348,7 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
|
||||
| option | default | meaning |
|
||||
|---|---|---|
|
||||
| `max_w` | 2000 | Hard limit on what may be commanded. Start low, raise after commissioning |
|
||||
| `max_w` | 2000 | Hard limit on what may be commanded. Start low, raise after commissioning. **Not read when `inverters` is declared** — each entry carries its own, and the site ceiling is their sum |
|
||||
| `gain` | 0.6 | Correction per cycle. **At the limit — do not raise** |
|
||||
| `slew_w` | 1000 | Maximum change per cycle |
|
||||
| `deadband_w` | 15 | Ignore errors smaller than this |
|
||||
@@ -287,6 +363,10 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
| `sign_disagree_w` | 300 | Both the command and the meter must exceed this before a sign difference counts. Must stay **below `max_w`** or the watchdog can never fire, and the add-on refuses to start |
|
||||
| `sign_disagree_s` | 180 | How long they must stay opposed, continuously, before the failsafe trips |
|
||||
| `unit_sign_disagree_w` | 250 | **Two or more inverters only.** Both a unit's own share and its own measured power must exceed this before their sign difference counts. It is `saturation_w / 2`, so the smallest divergence it can see is exactly the gap at which the loop already calls the inverter "not following". Must stay **below `max_w`** or it can never fire, and the add-on refuses to start |
|
||||
| `unit_sign_disagree_s` | 85 | **Two or more inverters only.** How long one unit's command and its own power must stay opposed before that unit is parked |
|
||||
| `site_sign_disagree_w` | 300 | **Two or more inverters only.** Threshold for the site-wide check - the sum of the commands against the meter. The same 300 W as `sign_disagree_w`, for the same reason: near zero the sign is noise |
|
||||
| `site_sign_disagree_s` | 325 | **Two or more inverters only.** How long the site's total command and the meter must stay opposed before every inverter is parked. Longer than `sign_disagree_s` because the command has to cross zero over a rail that is the sum of the roster, at a `slew_w` that is not - measured at 110 s with one inverter and 215 s with two |
|
||||
|
||||
#### The sign-disagreement failsafe
|
||||
|
||||
@@ -298,6 +378,43 @@ there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
|
||||
#### ⚠️ At two or more inverters this is TWO checks, not one (SAFETY-30)
|
||||
|
||||
The paragraph above describes what a **one-inverter** install does, and it is
|
||||
unchanged: there is one meter, one actuator, and comparing the command against
|
||||
the meter is comparing a thing with a view of itself.
|
||||
|
||||
With a second inverter that stops being true. The meter answers for **both**
|
||||
units, so a command put on one of them can be opposed to it with nothing wrong
|
||||
(inverter A charging while inverter B discharges more), and - the worse
|
||||
direction - a unit genuinely driving the wrong way can be **hidden**, because its
|
||||
sibling's watts arrive at the meter and the sum looks healthy. So the check
|
||||
splits in two, and they are different faults:
|
||||
|
||||
- **Per inverter** — that unit's own share against **its own measured power**
|
||||
(the `batt_entity` reading, register 0x0518). This catches *"this inverter is
|
||||
not doing what it was told"*. Only that inverter is parked; the site keeps
|
||||
running on the one that works. Thresholds: `unit_sign_disagree_w` /
|
||||
`unit_sign_disagree_s`.
|
||||
- **Site-wide** — the **sum** of what every inverter has standing, against the
|
||||
meter. This catches *"the site as a whole is pushing the wrong way"*, which no
|
||||
per-inverter check can see because every unit may be faithfully executing its
|
||||
share of a number that is itself wrong. **Every** inverter is parked and the
|
||||
banner names the site rather than an inverter. Thresholds:
|
||||
`site_sign_disagree_w` / `site_sign_disagree_s`, latched under flat
|
||||
`site_sign_tripped` in `/data/state.json`.
|
||||
|
||||
Both latch, both are cleared by the same *stop, then start*, and both survive a
|
||||
restart. **On a one-inverter install neither pair does anything at all** - the
|
||||
two questions are the same question there, and only the check described above is
|
||||
armed.
|
||||
|
||||
This is **not** the circulating-power alarm further down: that one compares the
|
||||
inverters *against each other* and catches them pushing power through each other,
|
||||
which nets to zero at the meter and which no command is evidence about. It is
|
||||
also not the saturation freeze, which is a *magnitude* test that shapes the loop
|
||||
rather than a *direction* test that parks an inverter.
|
||||
|
||||
**It does not clear itself, and restarting the add-on does not clear it either.**
|
||||
Pressing *Start / stop control* twice — stop, then start — is the only thing that
|
||||
does. That is deliberate on both counts:
|
||||
@@ -306,7 +423,13 @@ does. That is deliberate on both counts:
|
||||
always vanishes the instant the trip works. A watchdog that took that as proof
|
||||
the fault was over would hand the inverter straight back to the loop that was
|
||||
driving the wrong way, three minutes later, forever.
|
||||
- The trip is written to `/data/state.json` and restored on startup. Restarting
|
||||
- The trip is written to `/data/state.json` — under
|
||||
`unit/<inverter>/sign_tripped`, one key per inverter since DEV-02, so a trip
|
||||
caused by one inverter cannot latch another — and restored on startup. The
|
||||
pre-DEV-02 flat `sign_tripped` is written and cleared alongside it as the
|
||||
**rollback view**, so downgrading the add-on past DEV-02 still finds the
|
||||
latch, and a trip taken while the install is rolled back is re-armed by the
|
||||
version that comes back up rather than silently lost. Restarting
|
||||
the add-on is the first thing most people try when they see a red banner, and
|
||||
a latch that a restart clears would bring the controller back **armed, into the
|
||||
same fault, unattended** — and under a Supervisor that restarts a crashed add-on
|
||||
@@ -755,6 +878,82 @@ unchanged is 12 W, which is inside the 15 W deadband — so the command there is
|
||||
parked at 0 W and the two halves of the rule cannot both be true. At the schema
|
||||
floor of 60 s that figure is 60 W and only the margin is left.
|
||||
|
||||
### The circulating-power alarm (SAFETY-31)
|
||||
|
||||
> **Only at two or more inverters.** At the shipped roster of one this quantity
|
||||
> is identically zero for every reading, no claim is ever filed, and the status
|
||||
> page says *n/a* rather than pretending to watch it.
|
||||
|
||||
Two inverters can move a great deal of energy while the meter reads almost
|
||||
nothing. Inverter A charging at 3 kW while inverter B discharges at 3 kW nets
|
||||
**~0 W at P1**: the site looks idle, and in reality the packs are being cycled
|
||||
through two round-trip conversion losses continuously, for no benefit.
|
||||
|
||||
**Nothing else in this add-on can see it, and that is structural rather than an
|
||||
oversight.** Every other guard is a consumer of the *net* figure at the grid
|
||||
connection — the sign-disagreement failsafe gates on `abs(grid_w) > 300 W` and
|
||||
that gate never opens at a netted zero; the capacity-peak guard and the tariff
|
||||
both bill grid exchange. Circulating power is precisely the component of
|
||||
per-inverter power that the sum destroys.
|
||||
|
||||
So the add-on computes a quantity none of them were computing:
|
||||
|
||||
```
|
||||
circulating_w = Σ|Bᵢ| − |ΣBᵢ|
|
||||
```
|
||||
|
||||
Zero when the units pull the same way. `2 × min(|B_a|, |B_b|)` when they oppose
|
||||
— twice the power going round the loop, which is what both conversion stages are
|
||||
processing between them. It is published as
|
||||
`sensor.goodwe_circulating_power`, deliberately **beside** the grid figure:
|
||||
*"grid 0 W, circulating 6000 W"* is the whole fault in two dashboard rows, and
|
||||
no arithmetic on the grid figure alone can produce the second one.
|
||||
|
||||
**It is derived from each inverter's own measured power, not from what the
|
||||
controller believed it commanded.** That matters because the allocator already
|
||||
*refuses* to command opposite directions (ALLOC-01's sign-coherence gate), so a
|
||||
figure computed from the allocation record would read zero by construction and
|
||||
detect nothing. What this catches is circulation **nobody commanded** — a unit
|
||||
ignoring or lagging its share, a stale share still being executed, or an
|
||||
inverter doing something of its own accord.
|
||||
|
||||
| option | default | meaning |
|
||||
|---|---|---|
|
||||
| `circulation_w` | 700 | Watts of measured opposition below which nothing is reported |
|
||||
| `circulation_hold_s` | 75 | Seconds it must stand there continuously before the trip |
|
||||
|
||||
**Why 700 W and 75 s, and why neither is a round number.** Both were read off
|
||||
924 closed-loop runs on the two-master test rig in which *nothing* was faulty,
|
||||
swept across the whole range the schema accepts for `gain` and `slew_w`. A
|
||||
momentary opposition is **legitimate**: writes to the inverters are serialised,
|
||||
so on a reversing cycle one unit gets its new number up to a control cycle
|
||||
before its sibling, both slew through zero, and between the two crossings they
|
||||
genuinely oppose. The worst *continuous* legitimate opposition, by threshold,
|
||||
was **505 s at 100 W, 40 s at 250 W, 10 s at 300 W and 5.0 s — one control
|
||||
cycle — at 400 W and above**. The knee is 400 W and it is the schema floor;
|
||||
below it, ordinary operation would hold the sensor over the line for minutes and
|
||||
no usable window could tell that from a fault. 700 W carries margin above the
|
||||
knee because the second inverter's ramp and lag are not yet measured. 75 s is
|
||||
15× the worst legitimate episode, 2.5× the firmware's own 30 s link-veto window,
|
||||
and comfortably inside the 900 s quarter that bills the capacity tariff.
|
||||
|
||||
**What happens when it trips, and what it honestly cannot do.** The site is
|
||||
commanded **0 W on every inverter** and latched there until you press start.
|
||||
That is not aimed at making a misbehaving inverter stop — if a unit has stopped
|
||||
listening, no command will reach it. It does two things that do not need its
|
||||
cooperation: it removes *this controller* as one of the two participants in the
|
||||
loop, and it makes anything still happening **visible at the meter** instead of
|
||||
cancelled at it, where the ordinary guards can see it. **If the grid reading
|
||||
does not move after the trip, one inverter is no longer listening and the
|
||||
remaining actuator is a human at the isolator.**
|
||||
|
||||
**The alarm survives a Home Assistant restart.** The latch is written to `/data`
|
||||
and the notification is re-raised on the first cycle after every start —
|
||||
`persistent_notification` lives only in memory, and an alarm that vanishes with
|
||||
a restart is how a real outage on this system went unseen for over six hours.
|
||||
Restarting does **not** clear the trip; starting control from the add-on UI
|
||||
does, and only after you have read why.
|
||||
|
||||
### Energy price providers
|
||||
|
||||
> **A fetched price moves energy only when you switch arbitrage on.** This
|
||||
@@ -979,6 +1178,6 @@ abort one.
|
||||
## Status entities
|
||||
|
||||
If an MQTT broker is available the add-on publishes setpoint, grid power,
|
||||
battery power, state of charge, maintenance phase and controller status by MQTT
|
||||
discovery. This is observability only — the controller works fine without a
|
||||
battery power, circulating power, state of charge, maintenance phase and
|
||||
controller status by MQTT discovery. This is observability only — the controller works fine without a
|
||||
broker, and MQTT problems can never affect control.
|
||||
|
||||
@@ -127,6 +127,186 @@ Two rules come out of it, and both are cheap:
|
||||
function, that pair is the first thing to try — TEST-16's two survivors were
|
||||
adjacent lines in one function and neither was individually live.
|
||||
|
||||
## The third way a check lies: its DATA cannot reach the failure it names
|
||||
|
||||
Stale bytecode manufactures survivors from a mutation that never ran. Masking
|
||||
manufactures them from a second guard doing the first one's work. This one
|
||||
manufactures them from a **fixture**: the check runs, the assertion is
|
||||
evaluated, the sentence above it is true — and the numbers it compares are
|
||||
arranged so that the failure it describes could not have changed the answer.
|
||||
|
||||
It is not hypothetical and it is not rare. EIGHT instances in two weeks; four
|
||||
were found by review, two - CFG-04's fixture pair - by an author's own mutation
|
||||
battery, which is the cheaper place, one by review again, in the one
|
||||
place nobody had thought to point the rule at: not a check in the suite, but a
|
||||
COMMITTED EVIDENCE ARTIFACT four documents cite - and the eighth INSIDE THE FIX
|
||||
WRITTEN TO CLOSE THE SEVENTH.
|
||||
|
||||
⚠️ **AND IT HAS NOW APPEARED IN SIX CONSECUTIVE CARDS.** The seventh instance,
|
||||
MAINT-05's, is the one that says why: the defect is not carelessness about
|
||||
fixtures, it is that **a check and the thing it checks were built from the same
|
||||
constant**. Ask of every difference-claim not "is this assertion true" but
|
||||
"where did each side of this comparison come from" - and if the answer is the
|
||||
same place twice, the check is decoration.
|
||||
|
||||
* **ARB-03** shipped a call-site scan asserting that every `claims.append` in
|
||||
`cycle()` routes through `actuator_of()`. Its own parse **saw 3 of the 8
|
||||
appends**; the other five were invisible to it and would have passed however
|
||||
they were routed.
|
||||
* **ALLOC-01** shipped a replay generator to hunt for envelope escapes. It found
|
||||
**0**. A widened generator over the same allocator found **39,991**.
|
||||
* **DEV-02** shipped `"each unit's supervised bound is ITS OWN max_w — give
|
||||
inverter B a different rating and the claim filed on inverter B moves with
|
||||
it"`, comparing inverter B's bound against `_b2.max_w`. The fixture defaulted
|
||||
B's rating to A's, so it compared `(-5000, 5000)` against `(-5000, 5000)` —
|
||||
**a number against itself**. Filing both per-unit bounds from
|
||||
`self.inverters[0]` left **all 19 files green**.
|
||||
* **CFG-04** wrote *"an entry that omits `soc_entity` has NO SoC sensor and does
|
||||
not borrow the flat one"* against a fixture whose **flat `soc_entity` was
|
||||
blank**. Inherited and not-inherited were both `""`, so the mutation that
|
||||
makes `build_roster()` fall back to the flat key survived. The fixture now
|
||||
sets a real entity there, and the check asserts that the flat value is present
|
||||
as well as that the entry's is empty.
|
||||
* **CFG-04** also wrote *"main.py runs the per-unit range check
|
||||
UNCONDITIONALLY"* as a **substring test over `app/main.py`'s source**. The
|
||||
mutation that defeats it puts the call back inside `if entity:` — one level of
|
||||
indentation — and the substring is still there. That is habit 4 below in a new
|
||||
costume: the check asserted against the TEXT of the thing under test rather
|
||||
than against its behaviour. It now drives the shipped `run_control()` on a
|
||||
two-inverter config, **under a deadline**, because the mutation's real symptom
|
||||
is that the controller enters its loop and never returns.
|
||||
* **MAINT-05** shipped `Controller.__init__` calling
|
||||
`migrate_maint_keys(store, self.inverters[0].name, ...)` under a comment
|
||||
saying *"it targets `self.inverters[0].name` and NOT `UNIT_A` ... writing
|
||||
`UNIT_A` here would deposit an install's whole maintenance history under a
|
||||
name that is not on the roster at all"*. `inverter.UNIT_A` **is** the string
|
||||
`"inverter-a"`, and every two-pack fixture in `test_maintenance.py` named its
|
||||
first roster entry `inverter-a` — so the two expressions were the same value
|
||||
in every check that existed, and swapping them left **all 19 files green**
|
||||
while losing a real install's whole maintenance history. Two-pack fixtures are
|
||||
now `["garage", "shed"]`, each behind a precondition check (habit 1) that the
|
||||
first name is not `UNIT_A`.
|
||||
|
||||
⚠️ **AND THE POSTCONDITION HAD THE SAME SHAPE AS THE FIXTURE.**
|
||||
`store._verify_moves()` read back the keys it had just written, under the
|
||||
namespace it had just been handed — so it verified clean, and the caller
|
||||
stamped the schema marker, on a migration nothing would ever read. *A check
|
||||
that reads back the namespace it was handed cannot detect being handed the
|
||||
wrong one*: it compared a thing against itself, exactly as DEV-02's fixture
|
||||
compared `(-5000, 5000)` against `(-5000, 5000)`. The habit-2 fix is the same
|
||||
one — grade against something the thing under test did not supply, here the
|
||||
ROSTER the machines read.
|
||||
|
||||
⚠️ **AND THE FIX ITSELF CARRIED THE DEFECT, WHICH IS THE SIXTH CARD IN A ROW
|
||||
AND THE FIRST TIME IT HAS APPEARED *INSIDE* A REMEDY.** The fix round's
|
||||
recovery check was `migrate_maint_keys(_m5, ROSTER[0], ROSTER)` — the
|
||||
**corrected** name. It measures recovery along the one path where the operator
|
||||
has *already fixed the bug*, and nothing in the 19 files called
|
||||
`migrate_maint_keys()` twice with the **same wrong** `unit`. So the refusal
|
||||
the card was rejected twice to obtain lasted **exactly one start**: measured
|
||||
at Controller level over one persisted store, roster `["garage", "shed"]` —
|
||||
construction 1 `ok=False misdirected=4 moved=4 kept=0 marker=<absent>`,
|
||||
construction 2 `ok=True misdirected=0 moved=0 kept=4 marker=1`. On start 2
|
||||
rule 1 routes the wrongly-written keys to `rep.kept`, `rep.moved` is empty,
|
||||
the roster loop iterates over nothing, and the marker is stamped on a
|
||||
migration that reached no readable key — after which the early return skips it
|
||||
forever, *including after the call site is fixed*. The check was true and
|
||||
passed for the wrong reason. Habit **9** below is what falls out of it.
|
||||
|
||||
* **CFG-04's `tools/supervisor_shape_probe.py` §B** — and this one is the rule
|
||||
reaching outside the suite. The probe is the committed evidence that
|
||||
`config.yaml`'s `inverters: []` default is load-bearing, and four documents
|
||||
quoted it as answering *"Missing option 'inverters' in root"*. §B validated
|
||||
the reconstructed LIVE options blob, which is missing many required keys
|
||||
unrelated to this card, so its refusal named whichever of THOSE the validator
|
||||
reached first — `meter_freeze_s`, `p1_phase_export_entities` and
|
||||
`sign_disagree_w` on three different runs. The quoted string was never
|
||||
produced by the instrument. And the assertion was a bare **`not ok`**: delete
|
||||
`inverters: []` from `config.yaml` and §B went on printing **PASS**, blind to
|
||||
the exact regression it was cited for. §B is now an isolated counterfactual —
|
||||
the shipped defaults, and the same defaults minus that one key — asserting on
|
||||
the **key name in the refusal**; the mis-cited blob survives, relabelled, as
|
||||
§B2. Re-run with the default deleted it prints `2 CASE(S) FAILED` and exits 1.
|
||||
|
||||
⚠️ **A committed transcript is a check, and it decays like one.** Nothing in
|
||||
this document had been pointed at `tools/`, because the artifacts there are
|
||||
filed as *measurements* rather than as *checks* — and a measurement whose
|
||||
assertion cannot fail is exactly the thing this section is about. Two habits
|
||||
follow, and both are habit 5 and 6 below.
|
||||
|
||||
Note what these have in common with a masked rung: the mutation *runs*, and the
|
||||
suite is *honestly* green. Nothing in a purge, a fingerprint or a disassembly
|
||||
can see it, because the code under test really did behave identically on the
|
||||
stimulus it was given. The defect is upstream of the assertion, in what the
|
||||
check was handed.
|
||||
|
||||
**The rule, and it is one line:**
|
||||
|
||||
> **Any check asserting "X differs from Y" must be run once with X and Y
|
||||
> actually made different.**
|
||||
|
||||
Cheap habits fall out of it, and all of them are now used in this repository:
|
||||
|
||||
1. **Write the PRECONDITION as its own check.** `test_peakguard.py` 10g asserts
|
||||
that A and B have different ratings *before* it asserts that B's bound is
|
||||
B's. If a later edit makes them equal again, the precondition goes red rather
|
||||
than the claim going quietly vacuous.
|
||||
2. **Assert against literals, not against the expression under test.**
|
||||
`== [(-_b2.max_w, _b2.max_w)]` cannot distinguish "B's number" from "the
|
||||
number this fixture happens to have twice"; `== (-3000.0, 3000.0)` beside a
|
||||
printed `A = 5000` can.
|
||||
3. **Print what the check saw.** Every one of the three above would have been
|
||||
caught by a human reading one line of output — `supervised bounds by
|
||||
actuator: {'inverter-a': (-5000, 5000), 'inverter-b': (-5000, 5000)}` is
|
||||
self-evidently not evidence of a difference.
|
||||
|
||||
4. **Assert on the BEHAVIOUR, not on the source text of the thing under test.**
|
||||
A substring test over a module is a check on how the code is spelled;
|
||||
whitespace, an alias or a moved line defeats it while the property it names
|
||||
is gone. `test_inverter.py` part 10 has one of each — a source pin for a
|
||||
claim that genuinely IS about the code's shape, and a driven `run_control()`
|
||||
for a claim about behaviour — and the second replaced the first after the
|
||||
mutation battery walked straight through it.
|
||||
5. **A check whose failure mode is a HANG needs a deadline.** Otherwise the
|
||||
mutation that defeats it produces a CI timeout with no name attached, which
|
||||
reads like flaky infrastructure and gets retried rather than read.
|
||||
6. **Assert on the CONTENT of a refusal, not on the fact that one happened.**
|
||||
`not ok` is satisfied by any error at all, including one about a different
|
||||
key on a different blob. `"Missing option 'inverters' in root" in out` goes
|
||||
red the moment the refusal stops being about the thing it is cited for. This
|
||||
is habit 2 in the negative direction: a refusal, like a difference, has to be
|
||||
asserted against a literal.
|
||||
7. **Vary ONE thing in a counterfactual, and vary it from an ACCEPTED
|
||||
baseline.** `supervisor_shape_probe.py` §B validates the shipped defaults
|
||||
first, precisely so the refusal on the next line has nowhere else to come
|
||||
from. Without the accepted baseline the second line is a refusal of unknown
|
||||
provenance, which is what §B used to print.
|
||||
8. **A committed transcript is a check.** Anything under `tools/` that a
|
||||
document quotes is subject to every rule above, and to the mutation battery:
|
||||
break the property, re-run the instrument, and confirm the transcript goes
|
||||
red. `inverters: []` was deleted from `config.yaml` and the probe re-run
|
||||
against `ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0` for
|
||||
exactly that reason.
|
||||
9. **Exercise a refusal a SECOND time with the SAME wrong input — not the
|
||||
corrected one.** A guard that refuses once and then admits the same bad
|
||||
caller is not a guard, it is a delay, and the second call is a *different
|
||||
code path* whenever the first call left state behind. MAINT-05's roster
|
||||
grading iterated the keys it had just **written**; on the second start the
|
||||
same wrong caller found them already present, they moved to the
|
||||
`already namespaced` list, and the loop graded an empty set. Re-running with
|
||||
the **fixed** argument — which is what the check did — measures the operator's
|
||||
recovery, never the persistence of the refusal. Ask of every refusal: *what
|
||||
does this do when the caller has not been fixed and simply runs again?* And
|
||||
assert the **shape** of that second report, not only its verdict, so the
|
||||
check cannot silently revert to grading the first path.
|
||||
|
||||
And the mutation-table consequence: **a variant is not covered because a
|
||||
near-miss of it is.** DEV-02's table listed the *actuator* variant of the
|
||||
per-unit claim defect (`device`/`supervised` filed without `inv`), which the
|
||||
static routing pin catches. The *bound* variant — right actuator, wrong
|
||||
numbers — is a different defect with a different fix, and it was absent. Both
|
||||
are in the table now.
|
||||
|
||||
## Where each surface stands
|
||||
|
||||
* **Local and dev-harness runs — the exposed one.** This is where FCST-03 hit
|
||||
@@ -175,6 +355,8 @@ commit and PR bodies.
|
||||
| **TARIFF-01** reviewer survivor: `record_block()` ignoring its `policy` argument (0dbd485) | **re-verified — still a survivor** | re-run here through `tools/mutation_run.sh` against the 15 suites that were on the record, all green with `billed_w(block, policy)` mutated to `billed_w(block, POLICY_NET)`. The recorded diagnosis holds: every block reaching the store is single-phase, where NET, SUM and MAX collapse. **Now CLOSED by TEST-13** (`test_tariff.py` section 7), which round-trips section 7's own unbalanced `(3000, 500, -200) W` block THROUGH the store under each policy - three distinct banked figures, so a hardcoded policy takes at least two of them red. Third instance of "a stimulus evaluated where the quantity it grades is degenerate", after WITNESS-02's span normalisation and TARIFF-01's own DST window. |
|
||||
| **SAFETY-25** 8 mutations against `test_peakguard.py` part 10, then 9 more after review, all red | **not at risk** | each run against a tree copied fresh with `__pycache__` excluded and mounted `:ro`, so no `.pyc` existed to go stale - the same structural immunity recorded for CI above. Byte deltas recorded on the PR; none is `+0 B`. All are **reds**, which is the direction this defect cannot fabricate. ⚠️ The second round exists because the first round's mutations were all aimed at DISARMING the guard, and the claim part 10 actually made was about the guard being FIXED - the reviewer built the fix and the suite stayed green. Bytecode was never the issue there; an unaimed battery was. |
|
||||
| **SAFETY-03** reviewer survivor: `abs()` dropped from `clamp_to_rating`'s limit (6aabb83) | **re-verified — still a survivor** | re-run the same way, all 15 green. Also as recorded: unreachable under the `int(100, 5000)` schema. |
|
||||
| **MAINT-05 round 3**, `migrate_maint_keys()` marker gate `if rep.ok:` → `if rep.ok or rep.kept:` (`+12 B`) | **was a survivor — now CLOSED** | measured against head `65cddf3` under the purge, tree mounted `:ro`, `19/19 PASS`. It stamps the schema marker on a migration that LOST state, defeating the older `lost` guard as well as the new `misdirected` one, because every check that reached the marker did so on a store whose `kept` list was empty. Closed by `test_maintenance.py` **9d**; the mutation is now red on three named checks. |
|
||||
| **MAINT-05 round 3**, `migrate_unit_keys()` marker gate `if rep.ok:` → `if rep.ok or rep.kept:` (`+12 B`) | **found here — SAFETY-02's half, now CLOSED** | the SAME mutation one function up, on the LATCH migration rather than the history one. Measured a survivor against this branch under the purge, `:ro`, `19/19 PASS`, then closed by `test_inverter.py` part 10's new fixture — a store with `unit/inverter-a/sign_reason` already present (so `kept` is non-empty) whose `sign_tripped: true` write is dropped. Shipped: marker withheld. Mutant: marker stamped on a **disarmed latch**, and the next start skips the migration that would have re-armed it. |
|
||||
| **TARIFF-01**'s other three survivors, **SAFETY-03**'s `describe()` survivor, **TARIFF-02**'s M3/M5/M7, **SAFETY-18**'s three | **still unverified** | recorded before the purge discipline, with no byte delta on the record, so a `+0 B` same-second revert cannot be excluded. All are survivors, which is the direction this defect fabricates. TARIFF-02's and SAFETY-18's were **closed by later commits whose claims are reds**, so what is unverified is the *diagnosis*, not the current state of the code. |
|
||||
|
||||
**Nothing here says a past result is wrong.** The two survivors re-run above
|
||||
|
||||
@@ -0,0 +1,654 @@
|
||||
"""One site grid target, divided across N inverters so that the shares SUM to it.
|
||||
|
||||
⚠️ THE REASON THIS EXISTS, AND IT IS NOT EFFICIENCY. The control primitive in
|
||||
this system is METER EMULATION: the master reports a FABRICATED grid reading
|
||||
(0x056E direction, 0x056F magnitude, FC 0x10, every 1-2 s) and the inverter
|
||||
regulates ITSELF to it. So one number means "the battery moves X W" to this
|
||||
add-on and "the grid is at X W" to the inverter - an identity that holds ONLY at
|
||||
N=1. Hand two inverters the same target and each supplies it IN FULL: the loop
|
||||
gain at the meter becomes N times the per-unit gain.
|
||||
|
||||
That is measured, not argued. On admin/goodwe's two-master rig (TEST-19,
|
||||
`sim/sitesim.py --table`, the add-on's own `compute()` in the loop and the
|
||||
firmware's own encoder on the wire):
|
||||
|
||||
N=2 gain 0.6 BROADCAST worst export -400 W (N=1: +10 W)
|
||||
N=2 gain 1.0 BROADCAST commands [1000, 2000, 1000, 0] W,
|
||||
grid [0, -2000, 0, +2000] W, tail p2p 4000 W,
|
||||
FOREVER, and not one guard fires.
|
||||
|
||||
`gain: 1.0` is what config.yaml:374 accepts as its documented maximum. The sign
|
||||
watchdog is evaluated on every one of those cycles and never trips, because the
|
||||
disagreement flips on alternate ticks and never holds its 180 s window. So the
|
||||
broadcast fault is not merely inefficient: it is invisible to every detector
|
||||
this repository has.
|
||||
|
||||
THE FIX IS STRUCTURAL, WHICH IS WHY IT IS A MODULE AND NOT A TUNING CHANGE
|
||||
=========================================================================
|
||||
ONE integrator on P1, above the split (§10.3, and `compute()` is that
|
||||
integrator). Its output S is the SITE's grid target. This module turns S into
|
||||
per-unit shares with one invariant:
|
||||
|
||||
sum(shares) + unmet_w == S, with unmet_w == 0 whenever the envelopes allow
|
||||
|
||||
and each inverter is then told a function of ITS OWN SHARE, never of the shared
|
||||
measurement. Write s_i = a_i * S with sum(a_i) = 1. Each unit closes its own
|
||||
loop with per-unit gain g_i, so the gain seen AT THE METER is
|
||||
|
||||
gbar = sum(a_i * g_i)
|
||||
|
||||
which is a CONVEX COMBINATION of the per-unit gains and therefore lies in
|
||||
[min g_i, max g_i] FOR ANY SPLIT. Compare the broadcast case, a_i = 1 for every
|
||||
unit, where the same sum is N * g and grows without bound in N.
|
||||
|
||||
⚠️ THAT IS THE WHOLE ARGUMENT, AND IT IS WHY THE WEIGHTS ARE A COMFORT CHOICE.
|
||||
Nothing above constrains the a_i beyond summing to 1. So SoC, thermals and pack
|
||||
wear may set them freely and a BAD SPLIT CANNOT DESTABILISE THE SITE - it can
|
||||
only be unkind to one pack. That property is the reason §6.2 chose share
|
||||
allocation over a regulator/ballast arrangement, in which the ballast unit's
|
||||
share is a function of the shared measurement and the gain question comes back.
|
||||
|
||||
⚠️ WEIGHTS EXPRESS PREFERENCE. ENVELOPES EXPRESS PERMISSION. A weight of 0
|
||||
is "please do not use this unit", and it is honoured while any other unit
|
||||
has headroom - but it is NOT a constraint, because the SUM is the safety
|
||||
property and stranding capacity behind a preference would leave a standing
|
||||
error for the site integrator to chase forever. To make a unit genuinely
|
||||
unusable, close its envelope or leave it out of `live`. See `_fill()`.
|
||||
|
||||
WHAT THIS MODULE MUST NOT DO
|
||||
============================
|
||||
⚠️ IT MUST NOT READ P1. One integrator on the site measurement, above the split.
|
||||
A second reader of the meter is a second controller, and two controllers on one
|
||||
actuator is the failure the whole arbiter exists to prevent. Nothing in here
|
||||
takes a measurement of any kind: the inputs are S, the per-unit intervals, and
|
||||
per-tick liveness. That is checkable by reading the imports, and it is why there
|
||||
are none beyond the standard library.
|
||||
|
||||
⚠️ IT MUST NOT CACHE AN ENVELOPE. `plan()` is a pure function called once per
|
||||
tick with that tick's intervals. A unit's available range moves for reasons that
|
||||
have nothing to do with the allocator - a stale link, a pack at its floor, a
|
||||
device rating that failed to read - and an allocator holding a construction-time
|
||||
envelope over-allocates into a unit that cannot take it. There is no state here
|
||||
to hold one; that is deliberate and it is graded.
|
||||
|
||||
⚠️ ROUNDING IS A SAFETY PROPERTY. The setpoint register is 1 W (control.py says
|
||||
so where it quantises). A per-unit `round()` biases the sum by up to N/2 W every
|
||||
tick, and at 1-2 Hz a systematic 1 W bias is a PERMANENT standing error the site
|
||||
integrator will chase forever - it is not a rounding artefact, it is a slow
|
||||
offset with a control loop wound around it. So the sum is computed in INTEGER
|
||||
ARITHMETIC from an integer target and the fractional parts are settled by
|
||||
LARGEST REMAINDER (Hamilton): floor everything, then hand the leftover watts one
|
||||
at a time to the units with the largest discarded fraction. The sum cannot drift
|
||||
because no float ever enters it.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass, field
|
||||
from math import ceil, floor, inf
|
||||
|
||||
# The tolerance on a float comparison of watts. Envelopes arrive as floats from
|
||||
# config and from device registers; this is the width below which two of them
|
||||
# are the same number. It is never used on the sum - see the module docstring.
|
||||
EPS = 1e-9
|
||||
|
||||
|
||||
# --- why a unit is not in the envelope set, and why the whole thing refused ---
|
||||
# Named rather than spelled inline so that main.py, SAFETY-28's write gate and
|
||||
# the tests can all agree on which case fired without matching English.
|
||||
DROP_STALE = "stale link"
|
||||
DROP_CONTRADICTION = "contradicts itself"
|
||||
DROP_NO_INTEGER = "no integer setpoint in its interval"
|
||||
|
||||
REFUSE_SCOPE = "mis-routed claim"
|
||||
REFUSE_EMPTY = "no unit available"
|
||||
REFUSE_SIGN = "opposite directions"
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class UnitPlan:
|
||||
"""What ONE unit was told this tick, and why it was that and not more.
|
||||
|
||||
This is the per-unit half of the allocation record. `why` is written for an
|
||||
operator reading an action log at 2 a.m., not for a developer: it says which
|
||||
mechanism chose the number - the weighted fill, an envelope that ran out, a
|
||||
claim of the unit's own that outranked the site.
|
||||
"""
|
||||
unit: str
|
||||
share_w: int
|
||||
lo: float
|
||||
hi: float
|
||||
weight: float
|
||||
why: str
|
||||
pinned: bool = False
|
||||
clamped: bool = False
|
||||
dropped: bool = False # not commanded at all - see `within_envelope`
|
||||
|
||||
@property
|
||||
def span(self) -> str:
|
||||
return (f"[{'-inf' if self.lo == -inf else format(self.lo, '.0f')}, "
|
||||
f"{'+inf' if self.hi == inf else format(self.hi, '.0f')}]")
|
||||
|
||||
@property
|
||||
def within_envelope(self) -> bool:
|
||||
"""Is the number this unit was told ACTUALLY inside the interval?
|
||||
|
||||
⚠️ THIS IS ASKED, NOT ASSUMED. The record is what SAFETY-28 gates on,
|
||||
and a record that describes a share it did not check is worth less than
|
||||
no record: the half-open clamp defect shipped a line reading
|
||||
`inverter-a -> +500 W in [2000, +inf] (weighted share)` - the record
|
||||
stating, in the same breath, both the floor and the share below it, and
|
||||
agreeing with itself. The clamp is fixed, so this should now be true on
|
||||
every plan the allocator builds; that is exactly why it is cheap to
|
||||
assert rather than to trust.
|
||||
|
||||
A DROPPED unit is always within: it was told nothing. Its interval may
|
||||
be a contradiction (`lo > hi`), which no number is inside, and printing
|
||||
that as a violation would cry wolf on the one case that is already
|
||||
reported by name.
|
||||
"""
|
||||
if self.dropped:
|
||||
return True
|
||||
return self.lo <= self.share_w <= self.hi
|
||||
|
||||
def explain(self) -> str:
|
||||
if self.dropped:
|
||||
return (f"{self.unit} -> not commanded, envelope {self.span} "
|
||||
f"({self.why})")
|
||||
if not self.within_envelope:
|
||||
# Unreachable as the allocator stands. If it ever is reachable
|
||||
# again, the log says so in the line an operator is already reading
|
||||
# rather than in a line nobody wrote.
|
||||
return (f"{self.unit} -> {self.share_w:+d} W OUTSIDE {self.span} "
|
||||
f"({self.why}) - ENVELOPE VIOLATED, DO NOT WRITE")
|
||||
return f"{self.unit} -> {self.share_w:+d} W in {self.span} ({self.why})"
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class Allocation:
|
||||
"""EVERY TICK PRODUCES ONE OF THESE, including the ticks that refused.
|
||||
|
||||
⚠️ IT IS DESIGNED TO BE GATEABLE, because SAFETY-28 gates the write path on
|
||||
it. That means three things, and each is a decision rather than a
|
||||
convenience:
|
||||
|
||||
* `ok` is ONE boolean and it is the only thing a gate has to read. A gate
|
||||
that must parse a message, or check three fields in the right order, is a
|
||||
gate somebody gets wrong.
|
||||
* a REFUSAL still carries the record - `plans`, `dropped` and the reason -
|
||||
so the gate can say WHY it stopped the write instead of only that it did.
|
||||
A refusal that returns nothing is a refusal nobody can debug.
|
||||
* `unmet_w` is separate from `ok`. An allocation that could not place every
|
||||
watt is still SAFE TO WRITE and strictly better than commanding zero; it
|
||||
is the site target that was not fully met, not a broken allocation. Fusing
|
||||
the two would make a saturated inverter park the whole site.
|
||||
|
||||
`sum_w` is the integer the shares are required to add up to, and
|
||||
`quantisation_w` is the ONE rounding that produced it from `target_w`. Both
|
||||
are here so that "the shares sum to S" can be checked by a reader rather
|
||||
than believed: `sum(shares.values()) + unmet_w == sum_w` is an identity over
|
||||
integers, and `sum_w - target_w` is a single site-level rounding of at most
|
||||
half a watt that is NEVER distributed into a per-unit bias.
|
||||
"""
|
||||
target_w: float
|
||||
sum_w: int
|
||||
shares: dict = field(default_factory=dict)
|
||||
plans: tuple = ()
|
||||
dropped: tuple = () # ((unit, why), ...) - order is roster order
|
||||
unmet_w: int = 0
|
||||
quantisation_w: float = 0.0
|
||||
refused: str | None = None
|
||||
passthrough: bool = False # N<=1: the share IS the site target, unrounded
|
||||
# SAFETY-28. WHICH TICK PRODUCED THIS RECORD, as an opaque token minted by
|
||||
# the caller - `Controller.alloc_tick`, incremented once per resolution.
|
||||
#
|
||||
# ⚠️ IT IS AN INPUT, NOT A COUNTER THIS MODULE KEEPS. `plan()` is a pure
|
||||
# function and part 10 of test_alloc.py grades that by asserting the module
|
||||
# holds no state at all; a serial number incremented in here would be
|
||||
# exactly the cached-across-ticks thing the envelope rule forbids, wearing a
|
||||
# different hat. So the tick is handed in and handed back out, and the
|
||||
# freshness question is answered by whoever owns the clock.
|
||||
#
|
||||
# ⚠️ AND IT DEFAULTS TO None, WHICH THE WRITE GATE REFUSES. A record built
|
||||
# without a tick is not "tick zero", it is a record that cannot say when it
|
||||
# was made - and the gate fails closed on it. Every test in this repository
|
||||
# that calls `plan()` for its arithmetic gets None and does not care;
|
||||
# main.py stamps every record it puts on the write path.
|
||||
tick: int | None = None
|
||||
|
||||
@property
|
||||
def ok(self) -> bool:
|
||||
"""The one boolean SAFETY-28's write gate reads."""
|
||||
return self.refused is None
|
||||
|
||||
def authorises(self, unit: str, value: float, tick: int | None) -> str | None:
|
||||
"""Why `unit` may NOT be written `value` on tick `tick`, or None if it may.
|
||||
|
||||
⚠️ THIS IS THE QUESTION SAFETY-28 REPLACED A CONFIG-SHAPE PROXY WITH, and
|
||||
it lives on the record rather than in main.py so that the record is the
|
||||
thing that answers it. Before this, "two writers can never reach one
|
||||
actuator" was enforced by `len(validate.ACTUATOR_WRITE_KEYS) == 1` -
|
||||
true, but a statement about the OPTIONS SCHEMA. Add a per-inverter
|
||||
config (CFG-04) and there are two real writers with that length still 1:
|
||||
the check stays green while the property it protects is gone.
|
||||
|
||||
Asking the record instead makes the property mechanical. A number
|
||||
reaches the wire only if the single allocator placed it, on THIS tick,
|
||||
for THIS unit. A second writer with its own arithmetic cannot produce
|
||||
one, because it does not appear in a record; and it cannot borrow an old
|
||||
one, because the tick has moved on.
|
||||
|
||||
⚠️ `unmet_w` IS NOT CONSULTED AND MUST NOT BE. An allocation that could
|
||||
not place every watt is still SAFE TO WRITE - see this class's own
|
||||
docstring. Fusing the two would let one saturated inverter park the
|
||||
whole site, which is a worse outcome than the hole this gate closes.
|
||||
|
||||
⚠️ NOR IS 0 W ITS BUSINESS. The caller answers that one before it asks
|
||||
this, and the reason is at `Controller.write_refusal()`: a gate that can
|
||||
block the failsafe is worse than the hole it closes.
|
||||
"""
|
||||
if tick is None or self.tick is None or self.tick != tick:
|
||||
return (f"the allocation record on hand was made on tick "
|
||||
f"{self.tick!r} and this is tick {tick!r} - a record whose "
|
||||
f"envelopes have moved cannot authorise a write")
|
||||
if not self.ok:
|
||||
return f"the allocator refused this tick ({self.explain()})"
|
||||
if unit not in self.shares:
|
||||
return (f"{unit} has no share in this tick's allocation "
|
||||
f"({self.explain()})")
|
||||
share = self.shares[unit]
|
||||
if value != share:
|
||||
return (f"{value:+.0f} W is not {unit}'s share of this tick's "
|
||||
f"allocation, which is {share:+.0f} W ({self.explain()})")
|
||||
# ⚠️ THE RECORD IS ASKED WHETHER IT AGREES WITH ITSELF. `within_envelope`
|
||||
# exists because the half-open clamp defect once shipped a plan reading
|
||||
# `inverter-a -> +500 W in [2000, +inf]` - stating the floor and a share
|
||||
# below it in one breath - and `UnitPlan.explain()` renders that as
|
||||
# ENVELOPE VIOLATED, DO NOT WRITE. This is the DO NOT WRITE.
|
||||
#
|
||||
# Unreachable at the shipped roster of one, where the pass-through's
|
||||
# interval is (-inf, +inf) and every number is inside it. Graded anyway,
|
||||
# on a constructed record, because the branch PR #40's reviewer replaced
|
||||
# with `if False:` was unreachable too and the whole suite stayed green.
|
||||
for p in self.plans:
|
||||
if p.unit == unit and not p.within_envelope:
|
||||
return (f"the record contradicts itself: {p.explain()}")
|
||||
return None
|
||||
|
||||
def explain(self) -> str:
|
||||
"""One line an operator can act on."""
|
||||
if self.refused is not None:
|
||||
return (f"REFUSED to allocate {self.target_w:+.0f} W: "
|
||||
f"{self.refused}")
|
||||
if self.passthrough:
|
||||
return f"pass-through {self.target_w:+.0f} W (one unit, nothing to divide)"
|
||||
body = ", ".join(f"{u}{s:+d}" for u, s in sorted(self.shares.items()))
|
||||
out = f"{self.sum_w:+d} W as {body}"
|
||||
if self.unmet_w:
|
||||
out += f", {self.unmet_w:+d} W UNMET"
|
||||
if self.dropped:
|
||||
out += (" - dropped "
|
||||
+ ", ".join(f"{u} ({w})" for u, w in self.dropped))
|
||||
return out
|
||||
|
||||
|
||||
def _int_envelope(b):
|
||||
"""A unit's interval, narrowed to the integers a 1 W register can hold.
|
||||
|
||||
⚠️ NARROWED INWARD, ALWAYS. `ceil` on the floor and `floor` on the ceiling,
|
||||
so every integer in the result is inside the real interval. Rounding the
|
||||
other way would let a share of exactly the rating be commanded on a unit
|
||||
whose rating is 2499.5 W, which is the one direction an envelope must never
|
||||
move: the envelope is what `device` and `supervised` filed, i.e. what the
|
||||
hardware said it can do.
|
||||
|
||||
Infinities pass through untouched - an absent bound is not a large bound,
|
||||
and `ceil(-inf)` is not a number. A unit that filed nothing this cycle has
|
||||
exactly that interval, which is why this case is the common one at N>=2 and
|
||||
not an edge.
|
||||
"""
|
||||
lo = -inf if b.lo == -inf else ceil(b.lo - EPS)
|
||||
hi = inf if b.hi == inf else floor(b.hi + EPS)
|
||||
return lo, hi
|
||||
|
||||
|
||||
def _clamp_int(v, lo, hi):
|
||||
"""`v` as an int, pulled inside `[lo, hi]`. EACH END IS APPLIED ON ITS OWN.
|
||||
|
||||
⚠️ THE TWO ENDS ARE INDEPENDENT AND MUST BE TREATED SO. An earlier form
|
||||
substituted `v` itself for a missing bound and fed both into one
|
||||
`min(max(...))`, which reads as "an absent bound cannot bind" but is not
|
||||
what it does: with `hi == inf` the whole expression collapses to
|
||||
`min(max(v, lo), v) == v`, so a MISSING UPPER BOUND SILENTLY DISCARDED THE
|
||||
LOWER ONE. `_clamp_int(0, 2142, inf)` returned 0 - a share below a 2142 W
|
||||
floor the unit itself filed - and every caller here inherited it.
|
||||
|
||||
So: skip the end that is infinite, apply the end that is not, and never let
|
||||
one end's absence reach the other. `UnitBounds()` defaults to
|
||||
`(-inf, +inf)`, and this helper is the whole of the ticket's first
|
||||
deliverable ("each share clipped to that unit's UnitBounds interval"), so a
|
||||
one-sided envelope is the ordinary case, not an edge.
|
||||
"""
|
||||
v = int(v)
|
||||
if lo != -inf:
|
||||
v = max(v, lo)
|
||||
if hi != inf:
|
||||
v = min(v, hi)
|
||||
return v
|
||||
|
||||
|
||||
def _fill(order, weights, cap, amount):
|
||||
"""WATER-FILL: place `amount` watts across `order`, capped, by weight.
|
||||
|
||||
`amount` and every `cap` are NON-NEGATIVE magnitudes; the direction has
|
||||
already been taken out by the caller. Returns `(add, leftover)`.
|
||||
|
||||
THE LOOP IS THE STANDARD ONE and it terminates in at most len(order) rounds:
|
||||
share the remaining amount in proportion to weight; any unit whose share
|
||||
would exceed its cap is PINNED AT ITS CAP and dropped from the active set;
|
||||
repeat with what is left. A unit that is not capped in a round is not capped
|
||||
in any later round either, so nothing is revisited.
|
||||
|
||||
⚠️ AND THEN THE SECOND PASS, WHICH IS THE POLICY DECISION IN THIS FUNCTION.
|
||||
Units with weight 0 are excluded from the weighted rounds - that is what a
|
||||
zero weight is for. But if the weighted set fills up and watts remain, they
|
||||
are offered to the zero-weight units, EQUALLY, rather than being reported as
|
||||
unmet. The reason is the module docstring's: the weights are a comfort
|
||||
choice and the sum is the safety property, so a preference must never
|
||||
manufacture a standing error at the meter that the site integrator will then
|
||||
chase. To make a unit genuinely unusable, close its envelope - `cap` is
|
||||
obeyed absolutely and is never overridden here.
|
||||
"""
|
||||
add = {u: 0.0 for u in order}
|
||||
rem = float(amount)
|
||||
|
||||
for pool in (
|
||||
[u for u in order if weights[u] > 0.0],
|
||||
[u for u in order if weights[u] <= 0.0], # the last-resort pass
|
||||
):
|
||||
# Inside the last-resort pass every weight is 0, so the proportional
|
||||
# step needs a weight of its own; equal shares is the only choice that
|
||||
# does not invent a preference the caller did not express.
|
||||
w = {u: (weights[u] if weights[u] > 0.0 else 1.0) for u in pool}
|
||||
active = [u for u in pool if cap[u] > 0.0]
|
||||
while rem > EPS and active:
|
||||
total = sum(w[u] for u in active)
|
||||
capped = [u for u in active if rem * w[u] / total >= cap[u] - add[u]]
|
||||
if capped:
|
||||
for u in capped:
|
||||
rem -= cap[u] - add[u]
|
||||
add[u] = cap[u]
|
||||
active = [u for u in active if u not in capped]
|
||||
else:
|
||||
for u in active:
|
||||
add[u] += rem * w[u] / total
|
||||
rem = 0.0
|
||||
return add, rem
|
||||
|
||||
|
||||
def plan(target_w, bounds, *, weights=None, live=None, scope_errors=(),
|
||||
site_priority=None, site_key="site", tick=None) -> Allocation:
|
||||
"""Divide the site grid target `target_w` across the units in `bounds`.
|
||||
|
||||
`bounds` unit name -> that unit's interval for THIS TICK (arbiter stage 1,
|
||||
`UnitBounds`). Read per tick, never cached - see the module
|
||||
docstring. Duck-typed on `.lo`, `.hi`, `.gate`, `.pinned_w`,
|
||||
`.pinned_by` and `.contradiction` so that this module does not
|
||||
import the arbiter and cannot grow a dependency on claims.
|
||||
`weights` unit -> non-negative comfort weight. Missing units weigh 1.0.
|
||||
`live` the units whose master has reported recently enough to be
|
||||
commanded, or None for "all of them". A unit not listed is
|
||||
DROPPED and the record says so; the survivors then carry the
|
||||
whole site target, which is a real change in what the site can
|
||||
do and must never happen silently (AC 6).
|
||||
`scope_errors` the arbiter's mis-routing complaints. See REFUSE_SCOPE below.
|
||||
`site_priority` the priority of the SITE claim that chose `target_w`. It is
|
||||
what a unit's own winning SET is weighed against - see PINS.
|
||||
`site_key` the name to use when there are no units at all.
|
||||
`tick` an opaque token identifying the tick this record is FOR, handed
|
||||
straight back on the record. SAFETY-28's write gate compares it
|
||||
against the tick it is writing on, so that a record cannot be
|
||||
replayed after its envelopes have moved. It is an input rather
|
||||
than something this module counts, for the reason on the field.
|
||||
|
||||
⚠️ N<=1 IS A PASS-THROUGH AND IS BYTE-IDENTICAL TO WHAT SHIPPED. The share
|
||||
IS the site target, as a float, unclamped and unrounded. That is §6.2's N=1
|
||||
identity - with one inverter the fabricated grid reading and the battery
|
||||
setpoint are the same number - and it is also the compatibility promise:
|
||||
every existing test in this repository replays through here and must see the
|
||||
number it saw before ARB-03. Do not "tidy" this branch into the general path
|
||||
by giving it a roster of one; the general path rounds to an integer and
|
||||
applies the envelope, and both are behaviour changes on the live install.
|
||||
"""
|
||||
units = tuple(sorted(bounds))
|
||||
|
||||
# --- REFUSAL 1: the claim list that produced S is known to be mis-routed --
|
||||
# ⚠️ THIS IS THE ANSWER TO ARB-03's OPEN QUESTION, AND IT IS A REFUSAL
|
||||
# RATHER THAN AN INPUT. `scope_violations()` reports a claim filed on an
|
||||
# actuator its source's scope does not permit. It is tempting to CONSUME
|
||||
# one - to read a unit-scoped claim that landed on the site as an allocation
|
||||
# input - and that is wrong twice over. First, by the time this function
|
||||
# runs the mis-routed claim has ALREADY been partitioned by `resolve()`, so
|
||||
# its effect is baked into S or into somebody's interval and cannot be
|
||||
# undone from here; consuming it would mean re-routing, which would make
|
||||
# `actuator` advisory and hand every filing site a second chance to be
|
||||
# wrong. Second, and worse, promoting a unit claim that landed on the site
|
||||
# requires guessing WHICH unit it belonged to, and there is no information
|
||||
# here to guess with - `actuator_for()` exists precisely because that answer
|
||||
# is chosen where the claim is built. Applying it to ALL units would put one
|
||||
# inverter's rating on a sibling that does not have it.
|
||||
#
|
||||
# So what is left is that S itself may be wrong, and dividing a number that
|
||||
# may be wrong is worse than not dividing it. Refuse, and let main.py fail
|
||||
# toward inaction and shout - which is the same answer clause 3 of the
|
||||
# arbiter's own rule already gives to a contradiction.
|
||||
#
|
||||
# ⚠️ IT IS ABOVE THE N<=1 PASS-THROUGH ON PURPOSE, and that is the one place
|
||||
# this card touches the pass-through's behaviour. A correctly routed
|
||||
# one-inverter cycle CANNOT produce a scope violation - `scope_violations()`
|
||||
# only complains about a unit source on the site when the site has named
|
||||
# units, and a site source on a unit requires somebody to have hand-written
|
||||
# `actuator=` past `actuator_for()` - so this cannot fire on the shipped
|
||||
# install, and where it does fire the input is a known bug rather than a
|
||||
# state to pass through.
|
||||
if scope_errors:
|
||||
return Allocation(
|
||||
target_w=float(target_w), sum_w=int(round(float(target_w))),
|
||||
shares={}, plans=(), dropped=(),
|
||||
unmet_w=int(round(float(target_w))),
|
||||
quantisation_w=float(int(round(float(target_w)))) - float(target_w),
|
||||
refused=f"{REFUSE_SCOPE}: " + "; ".join(scope_errors), tick=tick)
|
||||
|
||||
if len(units) <= 1:
|
||||
only = units[0] if units else site_key
|
||||
share = float(target_w)
|
||||
return Allocation(
|
||||
target_w=float(target_w), sum_w=int(round(share)),
|
||||
shares={only: share},
|
||||
plans=(UnitPlan(only, int(round(share)), -inf, inf, 1.0,
|
||||
"N<=1: the share IS the site target"),),
|
||||
passthrough=True, tick=tick)
|
||||
|
||||
w = {u: 1.0 if weights is None else float(weights.get(u, 1.0))
|
||||
for u in units}
|
||||
for u, wu in w.items():
|
||||
if wu < 0.0 or wu != wu:
|
||||
raise ValueError(f"weight for {u!r} is {wu!r}; weights are "
|
||||
"non-negative comfort factors, not signed targets")
|
||||
|
||||
# ⚠️ THE TARGET IS ROUNDED ONCE, HERE, AND NOWHERE ELSE. Everything below
|
||||
# this line is integer arithmetic, which is what makes "the shares sum to S"
|
||||
# an identity rather than a tolerance. `round()` is banker's rounding: over a
|
||||
# long replay it is unbiased, where `int(x + 0.5)` would add a systematic
|
||||
# half-watt in the discharge direction. In practice `target_w` arrives from
|
||||
# `compute()` already quantised to `step_w` (10 W by default) so this is a
|
||||
# no-op on the live path; it is not a no-op for a peak-shaving floor or an
|
||||
# arbitrage setpoint, which are not quantised.
|
||||
sum_w = int(round(float(target_w)))
|
||||
quant = float(sum_w) - float(target_w)
|
||||
|
||||
# --- the envelope set, rebuilt from scratch every tick -------------------
|
||||
dropped = []
|
||||
ilo, ihi = {}, {}
|
||||
considered = []
|
||||
for u in units:
|
||||
b = bounds[u]
|
||||
if live is not None and u not in live:
|
||||
# AC 6. The survivor is about to carry this unit's share and the
|
||||
# record has to say so; `dropped` is how it says it, and main.py
|
||||
# logs the transition.
|
||||
dropped.append((u, DROP_STALE))
|
||||
continue
|
||||
if getattr(b, "contradiction", False):
|
||||
# A unit contradicting ITSELF - its own `lo` above its own `hi`.
|
||||
# Stage 1 already decided that parks THAT unit and not the site,
|
||||
# which is the whole point of the partition; here it means the unit
|
||||
# has no interval to allocate into.
|
||||
dropped.append((u, DROP_CONTRADICTION))
|
||||
continue
|
||||
lo, hi = _int_envelope(b)
|
||||
if lo > hi:
|
||||
# An interval that contains no integer. The register is 1 W, so
|
||||
# there is no number this unit could be commanded that both bounds
|
||||
# accept - dropping it is the only answer that does not violate one.
|
||||
dropped.append((u, DROP_NO_INTEGER))
|
||||
continue
|
||||
ilo[u], ihi[u] = lo, hi
|
||||
considered.append(u)
|
||||
|
||||
def refuse(why):
|
||||
return Allocation(
|
||||
target_w=float(target_w), sum_w=sum_w, shares={}, plans=(),
|
||||
dropped=tuple(dropped), unmet_w=sum_w, quantisation_w=quant,
|
||||
refused=why, tick=tick)
|
||||
|
||||
# --- REFUSAL 2: nobody is available ------------------------------------
|
||||
if not considered:
|
||||
return refuse(f"{REFUSE_EMPTY}: "
|
||||
+ ", ".join(f"{u} ({why})" for u, why in dropped))
|
||||
|
||||
# --- PINS: a unit's own SET, weighed against the site's -------------------
|
||||
# ⚠️ THIS IS THE DECISION ARB-03 DEFERRED TO HERE, IN ITS OWN WORDS: "Stage 1
|
||||
# states the constraint and records what it is gated on; deciding whether it
|
||||
# applies is stage 3's business." `UnitBounds.gate` is the priority of the
|
||||
# unit's own winning SET; `site_priority` is the priority of the SITE claim
|
||||
# that chose S. Clause 1 of the arbiter's rule, transposed to a site with
|
||||
# more than one actuator: the higher priority wins, and a tie goes to the
|
||||
# unit, because a claim about one pack is more specific than a claim about
|
||||
# the connection and specificity is what a tie has left to break on.
|
||||
#
|
||||
# A pinned unit is NOT in the water-fill. It is doing something of its own -
|
||||
# a maintenance drain, a failsafe park - and what it does still counts
|
||||
# toward the site sum, so the free units carry the REMAINDER. That is not
|
||||
# the allocator compensating for a disturbance, which would be a second
|
||||
# controller; it is the shares summing to S, which is the invariant. The
|
||||
# meter's own answer arrives next tick through the one integrator above.
|
||||
#
|
||||
# ⚠️ AND site_priority=None MEANS "NO SITE SET WAS NAMED", so every pin
|
||||
# stands. `resolve()` always passes the real one. A direct caller that
|
||||
# passes nothing is saying it has no site claim to weigh, and honouring the
|
||||
# unit's own highest-priority claim is the only safe reading of that.
|
||||
pinned = {}
|
||||
for u in considered:
|
||||
b = bounds[u]
|
||||
gate = getattr(b, "gate", None)
|
||||
if gate is None:
|
||||
continue
|
||||
if site_priority is None or gate >= site_priority:
|
||||
pv = getattr(b, "pinned_w", None)
|
||||
if pv is None:
|
||||
continue
|
||||
pinned[u] = _clamp_int(round(float(pv)), ilo[u], ihi[u])
|
||||
|
||||
free = [u for u in considered if u not in pinned]
|
||||
remainder = sum_w - sum(pinned.values())
|
||||
|
||||
# --- WATER-FILL over the free units --------------------------------------
|
||||
# `base` is the point of each envelope nearest zero: 0 for an ordinary
|
||||
# symmetric rating, and the forced end for an envelope that does not contain
|
||||
# zero. Filling from there rather than from `lo` is what keeps a unit that
|
||||
# is merely ALLOWED to charge from being TOLD to.
|
||||
base = {u: _clamp_int(0, ilo[u], ihi[u]) for u in free}
|
||||
placed = sum(base.values())
|
||||
need = remainder - placed
|
||||
up = need >= 0
|
||||
cap = {u: (ihi[u] - base[u]) if up else (base[u] - ilo[u]) for u in free}
|
||||
add, leftover = _fill(free, w, cap, abs(need))
|
||||
|
||||
exact = {u: base[u] + (add[u] if up else -add[u]) for u in free}
|
||||
|
||||
# --- LARGEST-REMAINDER ROUNDING -----------------------------------------
|
||||
# Floor every share, then hand out the discarded watts one at a time, worst
|
||||
# discarded fraction first. The sum is integer arithmetic end to end, so it
|
||||
# cannot drift; ties break on the unit name so that the same inputs give the
|
||||
# same allocation on every tick and on every host.
|
||||
share = {u: int(floor(exact[u] + EPS)) for u in free}
|
||||
for u in free: # floors can never leave the envelope,
|
||||
share[u] = _clamp_int(share[u], ilo[u], ihi[u]) # but say so anyway
|
||||
debt = remainder - sum(share.values())
|
||||
frac_order = sorted(free, key=lambda u: (-(exact[u] - floor(exact[u])), u))
|
||||
step = 1 if debt > 0 else -1
|
||||
while debt != 0:
|
||||
moved = False
|
||||
for u in (frac_order if debt > 0 else list(reversed(frac_order))):
|
||||
if debt == 0:
|
||||
break
|
||||
nxt = share[u] + step
|
||||
if (step > 0 and nxt <= ihi[u]) or (step < 0 and nxt >= ilo[u]):
|
||||
share[u] = nxt
|
||||
debt -= step
|
||||
moved = True
|
||||
if not moved:
|
||||
break
|
||||
|
||||
shares = dict(pinned)
|
||||
shares.update(share)
|
||||
unmet = sum_w - sum(shares.values())
|
||||
|
||||
# --- REFUSAL 3: SIGN COHERENCE, so circulating power is not expressible ---
|
||||
# ⚠️ REFUSED, NOT AVERAGED. Two shares of opposite sign mean one pack
|
||||
# discharging into the AC bus while another charges off it: energy round-
|
||||
# tripping through two conversion stages for no reason, and - this is the
|
||||
# part that makes it a safety property rather than an efficiency one -
|
||||
# INVISIBLE. The meter sees the net, which is exactly S, so the site
|
||||
# integrator is content; each unit sees a target it is meeting, so no
|
||||
# per-unit guard fires; the sign watchdog compares a command against the
|
||||
# meter and both agree. Nothing in this repository would ever report it.
|
||||
#
|
||||
# It cannot arise from an ordinary tick: the fill only ever moves shares in
|
||||
# ONE direction from a base that is zero whenever the envelope contains
|
||||
# zero, so opposite signs require an envelope that EXCLUDES zero (a forced
|
||||
# floor) or a pin. Those are the cases worth refusing, and the refusal is a
|
||||
# site-level one because the alternative - dropping the offending unit and
|
||||
# re-filling - would silently override a claim that outranked the loop.
|
||||
pos = sorted(u for u, s in shares.items() if s > 0)
|
||||
neg = sorted(u for u, s in shares.items() if s < 0)
|
||||
if pos and neg:
|
||||
return refuse(
|
||||
f"{REFUSE_SIGN}: {', '.join(pos)} would discharge while "
|
||||
f"{', '.join(neg)} charges - circulating power, which nets to "
|
||||
f"{sum_w:+d} W at the meter and is invisible to every guard")
|
||||
|
||||
plans = []
|
||||
for u in units:
|
||||
drop = dict(dropped).get(u)
|
||||
if drop is not None:
|
||||
plans.append(UnitPlan(u, 0, bounds[u].lo, bounds[u].hi, w[u],
|
||||
f"DROPPED: {drop}", dropped=True))
|
||||
continue
|
||||
if u in pinned:
|
||||
by = getattr(bounds[u], "pinned_by", None) or "its own claim"
|
||||
plans.append(UnitPlan(u, pinned[u], ilo[u], ihi[u], w[u],
|
||||
f"pinned by {by} at priority "
|
||||
f"{bounds[u].gate}", pinned=True))
|
||||
continue
|
||||
at_edge = share[u] in (ilo[u], ihi[u])
|
||||
why = "weighted share"
|
||||
if at_edge and cap[u] - add[u] <= EPS and abs(need) > EPS:
|
||||
why = "envelope full - its surplus went to the others"
|
||||
elif w[u] <= 0.0 and share[u] != base[u]:
|
||||
why = "last resort: the preferred units were full"
|
||||
plans.append(UnitPlan(u, share[u], ilo[u], ihi[u], w[u], why,
|
||||
clamped=at_edge))
|
||||
|
||||
return Allocation(target_w=float(target_w), sum_w=sum_w, shares=shares,
|
||||
plans=tuple(plans), dropped=tuple(dropped),
|
||||
unmet_w=int(unmet), quantisation_w=quant, tick=tick)
|
||||
@@ -25,11 +25,52 @@ Clause 2 is the interesting one. It is what makes "money outranks maintenance"
|
||||
a consequence of the priorities instead of a special case somebody can forget:
|
||||
the maintenance charge-only limit binds the loop, but a higher-priority peak
|
||||
shaving claim simply is not bound by it.
|
||||
|
||||
⚠️ AND WHICH ACTUATOR IS A CLAIM ABOUT? THAT QUESTION HAS AN ANSWER AGAIN.
|
||||
specs.md §6.1 declared `actuator: str` as the first field of `Claim` and the
|
||||
implementation shipped without it, so every claim was implicitly about "the one
|
||||
and only actuator" and `resolve()` returned one scalar. ARB-03 restores the
|
||||
field, because §6.2 decided the site grid target is ALLOCATED across several
|
||||
inverters and never broadcast to each of them - and an allocator needs a seam to
|
||||
occupy that a single scalar does not have.
|
||||
|
||||
So resolution is now THREE STAGES, and they are separate functions so that a
|
||||
test can construct a case at any one of them:
|
||||
|
||||
1. `pre_resolve()` - each inverter's OWN claims become an interval for that
|
||||
unit. One unit's claims, one unit's bounds.
|
||||
2. `site_resolve()` - the SITE claims become one grid target S. This is the
|
||||
rule above, unchanged, and it is deliberately the same
|
||||
code it was: at N=1 there are no unit claims, so this
|
||||
stage sees the whole list and answers exactly what the
|
||||
shipped arbiter answered.
|
||||
3. `allocate()` - THE SEAM. It turns S into per-inverter shares subject to
|
||||
stage 1's intervals. ALLOC-01 filled it: the allocator
|
||||
itself is `app/allocator.py` and the reasoning lives
|
||||
there, because it consumes intervals and a number and
|
||||
must never learn about claims, priorities or P1.
|
||||
|
||||
⚠️ THE STRUCTURAL PROPERTY, AND IT IS THE REASON FOR THE SPLIT. A per-inverter
|
||||
constraint is consumed by the allocator as an INTERVAL; it is never promoted
|
||||
into the site claim list. So a unit `hi` and a site `lo` are never terms of the
|
||||
same `lo > hi` test, and the contradiction clause below - which resolves to 0 W,
|
||||
a battery parked inside a billed quarter - cannot be reached across two
|
||||
inverters. That is DECISIONS/SAFETY-25-loop-soc-floor.md §0c, made mechanical:
|
||||
not "guarded against", NOT EXPRESSIBLE. Filing a unit constraint as a site claim
|
||||
to "keep it simple" is the whole bug, and `actuator_for()` is what stops a
|
||||
strategy doing it by hand.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass, field
|
||||
from math import inf
|
||||
|
||||
# ⚠️ ONE WAY ONLY. `allocator` knows nothing about claims, priorities or
|
||||
# this module - it consumes intervals and a number - so the dependency
|
||||
# cannot become a cycle and the allocator stays testable on its own, which
|
||||
# is what lets test_alloc.py sweep it hundreds of thousands of times
|
||||
# without building a claim list for each one.
|
||||
from . import allocator
|
||||
|
||||
# Priorities live here and nowhere else. The moment these become magic numbers
|
||||
# scattered through the strategies, the whole point of this module is lost.
|
||||
P_SAFETY = 100 # stopped, inputs missing, shutting down, device limits
|
||||
@@ -50,6 +91,183 @@ P_LOOP = 10 # ordinary grid-following
|
||||
SET = "set"
|
||||
LIMIT = "limit"
|
||||
|
||||
# --- actuators, and the two scopes a claim can have -------------------------
|
||||
# ⚠️ §6.2: THE GRID CONNECTION IS AN ACTUATOR TOO. It is the one every inverter
|
||||
# at the site shares, and two inverters regulating against one meter are two
|
||||
# writers on it - which is the failure this module exists to prevent, one level
|
||||
# up from the one it was built for. So it gets a name, and claims about it are
|
||||
# filed on that name rather than on nothing in particular.
|
||||
ACTUATOR_SITE = "site"
|
||||
|
||||
SCOPE_SITE = "site" # about the grid connection: one of these per site
|
||||
SCOPE_UNIT = "unit" # about one pack, one inverter, one device
|
||||
|
||||
# ⚠️ THE CLASSIFICATION, AND IT IS THE REAL OUTPUT OF ARB-03. Each entry is read
|
||||
# off what the claim is ABOUT at its construction site in main.py, not off which
|
||||
# module builds it. Getting an entry wrong is not cosmetic: a per-inverter
|
||||
# reserve filed as a site `hi` against the peak guard's site `lo` is `lo > hi`,
|
||||
# clause 3, 0 W - the battery parked in the billed quarter that SAFETY-25's memo
|
||||
# calls fatal. The reasoning is recorded here, at the line, because this table is
|
||||
# where a ninth source will be classified and the reasoning is what a future
|
||||
# reader needs in order to classify it correctly.
|
||||
CLAIM_SCOPE = {
|
||||
# --- SITE: about the grid connection ---------------------------------
|
||||
# main.py: `Claim.set("loop", P_LOOP, decision.target_w, ...)`. compute()
|
||||
# regulates `grid_w` - the P1 measurement - to zero. Its subject is the
|
||||
# meter, and §6.2's whole architecture is ONE integrator on P1 whose output
|
||||
# is then split. A site claim, and the one the split exists for.
|
||||
"loop": SCOPE_SITE,
|
||||
# main.py: `peakguard.claim(...)`. The quantity is the 15-minute average
|
||||
# OFFTAKE AT THE GRID CONNECTION, which is what the Belgian capacity tariff
|
||||
# bills. There is one quarter-hour peak per site, not one per pack.
|
||||
"peak": SCOPE_SITE,
|
||||
# main.py: `arbitrage.claim(...)`. It buys and sells at the grid against a
|
||||
# day-ahead price. The price is a property of the connection, and the energy
|
||||
# it trades crosses the meter.
|
||||
"arbitrage": SCOPE_SITE,
|
||||
# main.py: `Claim.set("safety", P_SAFETY, 0.0, "stopped" | "inputs missing")`.
|
||||
# ⚠️ READ BOTH CONSTRUCTION SITES BEFORE MOVING THIS ONE. Neither is about a
|
||||
# pack. "stopped" is the operator switching control off for the SITE, and
|
||||
# "inputs missing" is the SITE's own telemetry gone - the meter this whole
|
||||
# controller regulates against. Both must stop every inverter, and a site
|
||||
# SET at P_SAFETY is how that is said once rather than N times.
|
||||
"safety": SCOPE_SITE,
|
||||
# main.py: `Claim.set("circulation", P_SAFETY, 0.0, "circulating power")`.
|
||||
# SAFETY-31, and this one is a SITE claim for a reason worth writing down,
|
||||
# because the neighbouring `failsafe` entry looks like it and is not.
|
||||
#
|
||||
# `failsafe` is SAFETY-02: site-wide evidence, per-unit conclusion. It
|
||||
# compares the meter against THE COMMAND THIS CONTROLLER PUT ON ONE
|
||||
# ACTUATOR, so what it learns is about that actuator and the remedy is that
|
||||
# actuator.
|
||||
#
|
||||
# Circulating power is not a property any single inverter has. It is
|
||||
# `sum(|B_i|) - |sum(B_i)|`, defined over the whole roster and identically
|
||||
# zero for any one unit, and there is NO FACT OF THE MATTER about which of
|
||||
# two opposing inverters is the offender - a unit ignoring its share and a
|
||||
# sibling faithfully executing a share computed to sum with it produce the
|
||||
# same reading. Filing this per-unit would require inventing an attribution
|
||||
# the measurement cannot support, and would park one inverter while the
|
||||
# other went on feeding the loop. The evidence is site-level and so is the
|
||||
# remedy: stop commanding, everywhere, and say why.
|
||||
"circulation": SCOPE_SITE,
|
||||
# main.py: `Claim.set("sign_site", P_SAFETY, 0.0, "site sign disagreement")`.
|
||||
# SAFETY-30, and it is the twin of `failsafe` below rather than a duplicate
|
||||
# of it - the two exist BECAUSE the same words describe two different
|
||||
# measurements once there is more than one inverter.
|
||||
#
|
||||
# `failsafe` grades ONE unit's standing command against THAT UNIT'S OWN
|
||||
# measured power (register 0x0518). Its conclusion is "the actuator I am
|
||||
# driving is not doing what I told it", which is a fact about one device,
|
||||
# so it parks one device.
|
||||
#
|
||||
# This one grades the SUM of the standing commands against P1. Its
|
||||
# conclusion is "the site as a whole is driving the wrong way" - an inverted
|
||||
# gain, an integrator wound past the rail, a strategy on the wrong side of
|
||||
# the meter - and there is nothing per-unit about it: the quantity is a sum
|
||||
# over the roster and the offending number is the site target, which no
|
||||
# single inverter owns. Parking one unit on that evidence would leave the
|
||||
# rest of the site pushing the same way with the guard satisfied.
|
||||
#
|
||||
# ⚠️ AT N=1 IT IS NEVER FILED, and that is the identity rather than a
|
||||
# special case: with one inverter the sum of the commands IS that unit's
|
||||
# command and `failsafe` already carries exactly this trip, under the keys,
|
||||
# the banner and the claim an install has had since SAFETY-02 shipped.
|
||||
# `Controller.cycle()` does not even arm the site detector there.
|
||||
"sign_site": SCOPE_SITE,
|
||||
|
||||
# --- UNIT: about one pack, one inverter, one device -------------------
|
||||
# main.py: `Claim.limit("device", P_SAFETY, self.dev_min, self.dev_max,
|
||||
# "rating")`. The numbers are read off ONE inverter's own reported min/max.
|
||||
# Another inverter has another rating; there is no site rating.
|
||||
"device": SCOPE_UNIT,
|
||||
# main.py: `Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w")`.
|
||||
# `max_w` is the supervised cap on what this controller may WRITE to a
|
||||
# setpoint entity - §11.3's "the actuator is capped below the inverter
|
||||
# rating". It bounds a write to one device, like `device` does and for the
|
||||
# same reason, so it is scoped like `device`.
|
||||
"supervised": SCOPE_UNIT,
|
||||
# main.py: `Claim.set("failsafe", P_SAFETY, 0.0, "sign disagreement")`.
|
||||
# ⚠️ THE EVIDENCE IS PER-UNIT AND SO IS THE REMEDY - AND SINCE SAFETY-30 THE
|
||||
# FIRST HALF OF THAT SENTENCE IS TRUE. It used to read "the evidence is
|
||||
# site-wide and the remedy is not", because the watchdog compared THIS
|
||||
# unit's standing command against P1: a site measurement, attributed to one
|
||||
# actuator on the strength of §6.2's N=1 identity. That identity does not
|
||||
# survive a second inverter - at N>=2 the meter answers for a sibling this
|
||||
# unit's command says nothing about, in both directions (a false trip when
|
||||
# the sibling covers the meter, and a missed one when the sibling MASKS a
|
||||
# unit that really is reversed).
|
||||
#
|
||||
# So at N>=2 the comparison behind this claim is THIS unit's command against
|
||||
# THIS unit's own measured power - register 0x0518, per-instance since
|
||||
# DEV-02 - and the scope that was already right for the wrong reason is now
|
||||
# right for the right one. The site-wide half moved to `sign_site` above.
|
||||
# At N=1 the two are the same comparison and this claim is the one filed,
|
||||
# exactly as it shipped.
|
||||
"failsafe": SCOPE_UNIT,
|
||||
# main.py: `Claim.set("maintenance", P_MAINTENANCE, ...)` when the cycle owns
|
||||
# the setpoint, and `Claim.limit("maintenance", P_MAINT_SHAPE, hi=...)` when
|
||||
# it only shapes. §12's monthly recalibration is a PACK procedure - drain
|
||||
# this pack to its floor, charge this pack to full, recalibrate this pack's
|
||||
# coulomb counter. Two packs recalibrate on their own schedules.
|
||||
"maintenance": SCOPE_UNIT,
|
||||
}
|
||||
|
||||
|
||||
def actuator_for(source: str, unit: str, units=()) -> str:
|
||||
"""Which actuator a claim from `source` belongs on, given the site's roster.
|
||||
|
||||
⚠️ ROUTE THROUGH THIS, DO NOT PASS `actuator=` BY HAND. An unclassified
|
||||
source raises `KeyError` here rather than defaulting to the site, which is
|
||||
the one direction that is not safe to default in: a per-inverter constraint
|
||||
that lands in the site claim list is exactly the `lo > hi` this card exists
|
||||
to make unreachable. A ninth claim source has to be classified in
|
||||
CLAIM_SCOPE before it can be filed, and test_peakguard.py part 10f is the
|
||||
other half of that - it goes red on the line the ninth append is written.
|
||||
|
||||
⚠️ AND AT N=1 EVERY SOURCE ROUTES TO THE SITE. That is not the classification
|
||||
being ignored, it is §6.2's identity: with one inverter the fabricated grid
|
||||
reading and the battery setpoint are the same number, so the grid connection
|
||||
and the only unit ARE the same actuator and there is nothing to allocate.
|
||||
Splitting the list at N=1 would be a behaviour change on a live safety path -
|
||||
the `failsafe` and `maintenance` SET claims would stop competing with the
|
||||
site's for the winner, `explain()` would name a different source, and
|
||||
`loop_is_following()` reads that name. The identity holds only at N=1, so
|
||||
this function is the ONE place that stops relying on it, the day the roster
|
||||
grows.
|
||||
"""
|
||||
if CLAIM_SCOPE[source] == SCOPE_SITE:
|
||||
return ACTUATOR_SITE
|
||||
return ACTUATOR_SITE if len(units) <= 1 else unit
|
||||
|
||||
|
||||
def scope_violations(claims) -> list:
|
||||
"""Claims filed on an actuator their source's scope does not permit.
|
||||
|
||||
A list of one-line complaints, empty when the routing is right. This is the
|
||||
check `actuator_for()` cannot make on its own, because a caller can always
|
||||
write `actuator=` by hand: it grades the claim list that actually reached the
|
||||
arbiter, whatever built it.
|
||||
"""
|
||||
out = []
|
||||
# ⚠️ THE SECOND TEST IS CONDITIONAL ON THE SITE HAVING NAMED UNITS AT ALL,
|
||||
# and that is not laxity. At N=1 §6.2's identity holds and a per-inverter
|
||||
# source filed on the site is CORRECT - it is what `actuator_for()` returns.
|
||||
# The direction that produces `lo > hi` only exists once there is a second
|
||||
# actuator for the constraint to have belonged to.
|
||||
split = any(c.actuator != ACTUATOR_SITE for c in claims)
|
||||
for c in claims:
|
||||
scope = CLAIM_SCOPE.get(c.source)
|
||||
if scope is None:
|
||||
out.append(f"{c.source}: not classified in CLAIM_SCOPE")
|
||||
elif scope == SCOPE_SITE and c.actuator != ACTUATOR_SITE:
|
||||
out.append(f"{c.source}: a SITE claim filed on unit {c.actuator!r} - "
|
||||
f"it would bound one inverter's share instead of the grid")
|
||||
elif scope == SCOPE_UNIT and c.actuator == ACTUATOR_SITE and split:
|
||||
out.append(f"{c.source}: a UNIT claim filed on the site while the "
|
||||
f"site has named units - it can cross a site limit")
|
||||
return out
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class Claim:
|
||||
@@ -60,15 +278,76 @@ class Claim:
|
||||
lo: float = -inf # for LIMIT
|
||||
hi: float = inf # for LIMIT
|
||||
reason: str = ""
|
||||
# ⚠️ specs.md §6.1 DECLARES THIS FIELD FIRST AND IT IS LAST HERE, ON PURPOSE.
|
||||
# The spec's point is that a claim NAMES its actuator; the tuple position is
|
||||
# not the point, and it is load-bearing for two things that are. Every
|
||||
# construction in this repository passes `source` first, and
|
||||
# test_peakguard.py part 10f reads `Claim.set(...)`/`Claim.limit(...)`'s
|
||||
# FIRST POSITIONAL ARGUMENT off main.py's AST to pin the claim-source set -
|
||||
# the tripwire that guards SAFETY-25's deferred option. Moving `source` off
|
||||
# position 0 would silently blind that scan, which is this repository's named
|
||||
# failure mode. So the field is restored where it costs nothing.
|
||||
#
|
||||
# ⚠️ AND ITS DEFAULT IS THE SITE, EXPLICITLY. Not None, not "". A claim that
|
||||
# does not name an actuator is a claim about the grid connection and says so;
|
||||
# "unspecified" is what the shipped code already had, and it is what made
|
||||
# every claim implicitly about the one and only actuator.
|
||||
actuator: str = ACTUATOR_SITE
|
||||
|
||||
@staticmethod
|
||||
def set(source: str, priority: int, value: float, reason: str = "") -> "Claim":
|
||||
return Claim(source, priority, SET, value=value, reason=reason)
|
||||
def set(source: str, priority: int, value: float, reason: str = "", *,
|
||||
actuator: str = ACTUATOR_SITE) -> "Claim":
|
||||
return Claim(source, priority, SET, value=value, reason=reason,
|
||||
actuator=actuator)
|
||||
|
||||
@staticmethod
|
||||
def limit(source: str, priority: int, lo: float = -inf, hi: float = inf,
|
||||
reason: str = "") -> "Claim":
|
||||
return Claim(source, priority, LIMIT, lo=lo, hi=hi, reason=reason)
|
||||
reason: str = "", *, actuator: str = ACTUATOR_SITE) -> "Claim":
|
||||
return Claim(source, priority, LIMIT, lo=lo, hi=hi, reason=reason,
|
||||
actuator=actuator)
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class UnitBounds:
|
||||
"""What one inverter's OWN claims say about that inverter's share.
|
||||
|
||||
STAGE 1's output, one per unit, and the thing ALLOC-01 consumes. It is an
|
||||
INTERVAL plus the two facts an allocator cannot reconstruct from an interval:
|
||||
|
||||
* `pinned_w` - the value that unit's own winning SET asked for. A SET is not
|
||||
a bound: `resolve()` CLAMPS a set value into the limits rather than
|
||||
intersecting with it, and folding a 2500 W drain into `[2500, 2500]` would
|
||||
turn "clamped to the rating" into "contradicts the rating". So it travels
|
||||
beside the interval, not inside it.
|
||||
* `gate` - the priority of that winning SET, or None. Clause 2 applies a
|
||||
limit only at or above the winner's priority, and at N>=2 the winner may be
|
||||
a SITE set chosen at stage 2, i.e. AFTER this. Stage 1 states the
|
||||
constraint and records what it is gated on; deciding whether it applies is
|
||||
stage 3's business. Guessing here is how a maintenance charge-only `hi`
|
||||
would come to bind a peak discharge it does not outrank.
|
||||
|
||||
`contradiction` is a unit contradicting ITSELF - its own `lo` above its own
|
||||
`hi`. It parks that unit and says so; it does not park the site, which is the
|
||||
entire difference this card is about.
|
||||
"""
|
||||
lo: float = -inf
|
||||
hi: float = inf
|
||||
lo_src: str | None = None
|
||||
hi_src: str | None = None
|
||||
gate: int | None = None
|
||||
pinned_w: float | None = None
|
||||
pinned_by: str | None = None
|
||||
contradiction: bool = False
|
||||
|
||||
def explain(self) -> str:
|
||||
if self.contradiction:
|
||||
return (f"CONTRADICTION within the unit ({self.lo_src} lo="
|
||||
f"{self.lo:.0f} > {self.hi_src} hi={self.hi:.0f})")
|
||||
span = (f"[{'-inf' if self.lo == -inf else format(self.lo, '.0f')}, "
|
||||
f"{'+inf' if self.hi == inf else format(self.hi, '.0f')}]")
|
||||
if self.pinned_by is not None:
|
||||
return f"{span} around {self.pinned_by} -> {self.pinned_w:.0f} W"
|
||||
return span
|
||||
|
||||
|
||||
@dataclass
|
||||
@@ -78,6 +357,32 @@ class Resolution:
|
||||
bound_by: str | None = None # which limit actually changed it, if any
|
||||
contradiction: bool = False
|
||||
considered: list = field(default_factory=list)
|
||||
# --- the three-stage fields. ⚠️ APPENDED, AND DEFAULTED, ON PURPOSE: every
|
||||
# existing construction of this type is positional in its first five fields
|
||||
# and `target_w` still means exactly what it meant - the SITE grid target.
|
||||
# main.py assigns it to `self.target` unchanged.
|
||||
unit_bounds: dict = field(default_factory=dict) # stage 1, per actuator
|
||||
shares: dict = field(default_factory=dict) # stage 3, per actuator
|
||||
allocated: bool = True # False when stage 3 declined to split
|
||||
scope_errors: list = field(default_factory=list) # mis-routed claims
|
||||
# ALLOC-01, appended for the reason the four above were: `target_w` still
|
||||
# means the SITE grid target and every existing construction is untouched.
|
||||
#
|
||||
# `allocation` is stage 3's full record - what each unit was told and why,
|
||||
# what could not be placed, what was dropped. `shares` and `allocated` are
|
||||
# two fields OF that record, kept at the top level because main.py and four
|
||||
# test files already read them there. ⚠️ IT IS THE RECORD, NOT THE PAIR,
|
||||
# THAT SAFETY-28 GATES THE WRITE PATH ON: `allocated` says the allocator
|
||||
# stands behind the split, and `unmet_w` says how much of the site target it
|
||||
# could not place, and fusing those two would make one saturated inverter
|
||||
# park the whole site.
|
||||
allocation: object | None = None
|
||||
# The priority of the SITE claim that chose `target_w`. Stage 3 weighs a
|
||||
# unit's OWN winning SET against it - see `allocator.plan()`'s PINS note -
|
||||
# and getting it from here rather than recomputing it is what stops the two
|
||||
# rules drifting apart: this is set by the same line that picks the winner
|
||||
# `explain()` names.
|
||||
winner_priority: int | None = None
|
||||
|
||||
def explain(self) -> str:
|
||||
"""One line an operator can act on - this is the point of the module."""
|
||||
@@ -88,7 +393,107 @@ class Resolution:
|
||||
return f"{self.winner} -> {self.target_w:.0f} W"
|
||||
|
||||
|
||||
def resolve(claims: list) -> Resolution:
|
||||
def pre_resolve(unit_claims: list) -> UnitBounds:
|
||||
"""STAGE 1. One inverter's own claims -> that inverter's interval.
|
||||
|
||||
Clauses 1 and 2 of the rule, transposed: the unit's highest-priority SET
|
||||
names what the unit wants and gates which of the unit's limits apply, and the
|
||||
most restrictive of those limits gives the interval. Read UnitBounds on why
|
||||
the SET value is not folded into the interval.
|
||||
|
||||
⚠️ THE INPUT IS ONE UNIT'S CLAIMS AND NOTHING ELSE. A site claim reaching
|
||||
this function would become a bound on one inverter's share - the mirror image
|
||||
of the fault this card removes, and the reason `resolve()` partitions rather
|
||||
than filters twice.
|
||||
"""
|
||||
sets = sorted((c for c in unit_claims if c.kind == SET),
|
||||
key=lambda c: c.priority, reverse=True)
|
||||
gate = pinned_w = pinned_by = None
|
||||
if sets:
|
||||
gate, pinned_w, pinned_by = sets[0].priority, sets[0].value, sets[0].source
|
||||
|
||||
lo, hi = -inf, inf
|
||||
lo_src = hi_src = None
|
||||
for c in unit_claims:
|
||||
if c.kind != LIMIT or (gate is not None and c.priority < gate):
|
||||
continue
|
||||
if c.lo > lo:
|
||||
lo, lo_src = c.lo, c.source
|
||||
if c.hi < hi:
|
||||
hi, hi_src = c.hi, c.source
|
||||
return UnitBounds(lo, hi, lo_src, hi_src, gate, pinned_w, pinned_by,
|
||||
contradiction=lo > hi)
|
||||
|
||||
|
||||
def allocate(target_w: float, bounds: dict, *, weights=None, live=None,
|
||||
scope_errors=(), site_priority=None) -> tuple:
|
||||
"""STAGE 3. THE SEAM, AND SINCE ALLOC-01 IT IS OCCUPIED. `(shares, allocated)`.
|
||||
|
||||
⚠️ THE ALLOCATOR ITSELF IS `app/allocator.py` AND THE REASONING LIVES THERE.
|
||||
This is the adapter: it keeps the two-value shape every caller in this
|
||||
repository already reads, and it exists as a separate name so that the
|
||||
arbiter's three stages are still three functions a test can enter at any
|
||||
one of them. `allocator.plan()` returns the full record - use that when you
|
||||
need `unmet_w`, `dropped` or the per-unit reasons; `resolve()` stashes it on
|
||||
`Resolution.allocation` for exactly that.
|
||||
|
||||
What §6.2 fixed and what this delivers:
|
||||
|
||||
* SUM-INVARIANT. `sum(shares) + unmet_w == round(target_w)`, in integer
|
||||
arithmetic, so it cannot drift. Rounding is largest-remainder because a
|
||||
per-unit `round()` biases the sum by up to N/2 W every tick and at 1-2 Hz
|
||||
that is a PERMANENT standing error the site integrator chases forever.
|
||||
* EACH UNIT IS TOLD A FUNCTION OF ITS OWN SHARE, never of the shared
|
||||
measurement. That makes the gain at the meter a convex combination of the
|
||||
per-unit gains for ANY split, which is why the weights are a comfort
|
||||
choice and a bad split cannot destabilise the site.
|
||||
* WITH AT MOST ONE UNIT IT IS STILL A PASS-THROUGH, byte-identical to what
|
||||
ARB-03 shipped: the share IS the site target, as a float, unrounded and
|
||||
unclamped. §6.2's N=1 identity, and the compatibility promise every
|
||||
existing replay in this repository depends on.
|
||||
|
||||
⚠️ AND IT STILL DECLINES, WHICH IS NOT THE SAME LIST OF CASES AS BEFORE.
|
||||
ARB-03 declined at N>=2 because it had no allocator; that trigger is gone
|
||||
and the branch is NOT. It now fires when no safe split exists at all: a
|
||||
mis-routed claim, no unit left in the envelope set, or a split that could
|
||||
only be made by commanding one pack to charge while another discharges.
|
||||
Read `allocator.plan()` for each. main.py's refusal path and
|
||||
test_peakguard.py part 10h were re-aimed onto those rather than deleted -
|
||||
PR #40's reviewer proved that guard was unreachable and untested once, and
|
||||
removing its trigger without giving it a new one would rebuild the hole.
|
||||
"""
|
||||
return allocate_record(target_w, bounds, weights=weights, live=live,
|
||||
scope_errors=scope_errors,
|
||||
site_priority=site_priority)[:2]
|
||||
|
||||
|
||||
def allocate_record(target_w: float, bounds: dict, *, weights=None, live=None,
|
||||
scope_errors=(), site_priority=None, tick=None) -> tuple:
|
||||
"""`allocate()` plus the record - `(shares, allocated, allocation)`.
|
||||
|
||||
`tick` is SAFETY-28's freshness token: it identifies the tick the record is
|
||||
FOR and is handed straight through to `allocator.plan()`. Left None the
|
||||
record is UNSTAMPED, which the write gate refuses - so a caller that intends
|
||||
the record to authorise a write must pass one. Every existing caller in this
|
||||
repository wants the arithmetic and not the authority, and gets None.
|
||||
"""
|
||||
rec = allocator.plan(target_w, bounds, weights=weights, live=live,
|
||||
scope_errors=scope_errors,
|
||||
site_priority=site_priority, site_key=ACTUATOR_SITE,
|
||||
tick=tick)
|
||||
return rec.shares, rec.ok, rec
|
||||
|
||||
|
||||
def site_resolve(claims: list) -> Resolution:
|
||||
"""STAGE 2. The SITE claims -> one grid target.
|
||||
|
||||
⚠️ THIS FUNCTION IS THE SHIPPED ARBITER, UNCHANGED. It is a separate name and
|
||||
the same code, deliberately: at N=1 nothing is filed on a unit, so `resolve()`
|
||||
hands it the whole claim list and it answers what it has always answered.
|
||||
Every check in test_arbiter.py, test_watchdog.py, test_validate.py and
|
||||
test_peakguard.py replays through here unedited, which is the proof that
|
||||
ARB-03 changed no behaviour on the live path.
|
||||
"""
|
||||
sets = sorted((c for c in claims if c.kind == SET),
|
||||
key=lambda c: c.priority, reverse=True)
|
||||
|
||||
@@ -113,7 +518,8 @@ def resolve(claims: list) -> Resolution:
|
||||
|
||||
if lo > hi:
|
||||
return Resolution(0.0, winner.source, bound_by=None,
|
||||
contradiction=True, considered=considered)
|
||||
contradiction=True, considered=considered,
|
||||
winner_priority=winner.priority)
|
||||
|
||||
target = max(lo, min(hi, winner.value))
|
||||
bound_by = None
|
||||
@@ -122,4 +528,80 @@ def resolve(claims: list) -> Resolution:
|
||||
if binder is not None:
|
||||
bound_by = f"{binder.source}({binder.reason})" if binder.reason else binder.source
|
||||
|
||||
return Resolution(float(target), winner.source, bound_by, False, considered)
|
||||
return Resolution(float(target), winner.source, bound_by, False, considered,
|
||||
winner_priority=winner.priority)
|
||||
|
||||
|
||||
def resolve(claims: list, *, units=None, weights=None, live=None,
|
||||
tick=None) -> Resolution:
|
||||
"""The three stages, in order, over one cycle's claims.
|
||||
|
||||
`units` is the site's roster of inverters. Left None it is derived from the
|
||||
claims themselves, which is right for a caller that files a claim for every
|
||||
unit every cycle (main.py does - `supervised` is unconditional) and wrong for
|
||||
one that does not, so main.py passes the real roster rather than let a silent
|
||||
unit look like a smaller site.
|
||||
|
||||
`weights` and `live` are ALLOC-01's two per-tick inputs to stage 3, and both
|
||||
are per-TICK on purpose. `weights` is the comfort choice - SoC, thermals,
|
||||
wear - and cannot destabilise the site whatever it says. `live` is the set
|
||||
of units whose master has reported recently enough to be commanded; a unit
|
||||
left out of it is DROPPED from the envelope set and the record says so,
|
||||
because the survivor carrying a dead unit's share silently is the failure
|
||||
SAFETY-30 is about. ⚠️ NEITHER MAY BE CACHED BY A CALLER. A unit's range
|
||||
moves for reasons unrelated to the allocator - a stale link, a pack at its
|
||||
floor, a device rating that failed to read - so an envelope read once at
|
||||
construction over-allocates into a unit that cannot take it.
|
||||
|
||||
⚠️ AND THE ARGUMENT HAS TO BE HONOURED, WHICH IS NOT THE SAME AS EXISTING.
|
||||
Ignore it - derive always - and a unit that filed nothing this cycle ceases
|
||||
to exist: a site of two reads as a site of one and stage 3 passes the whole
|
||||
grid target through to the inverter that spoke, which is ARCH-01's fault
|
||||
with its own evidence removed. That mutation survived the whole suite until
|
||||
test_arbiter.py part 7 graded it on a SILENT unit.
|
||||
|
||||
⚠️ `tick` IS SAFETY-28's FRESHNESS TOKEN AND IT IS NOT OPTIONAL ON THE LIVE
|
||||
PATH. It identifies the tick this resolution is FOR, and it ends up on
|
||||
`Resolution.allocation.tick`, where the write gate compares it against the
|
||||
tick it is writing on. A record with no tick cannot authorise a write, which
|
||||
is why main.py passes `self.alloc_tick` and why a test that only wants the
|
||||
arbiter's arithmetic can leave it out and be sure it has not accidentally
|
||||
minted a licence to write.
|
||||
|
||||
⚠️ THE PARTITION IS BY `actuator`, AND IT IS A PARTITION, NOT A FILTER. Every
|
||||
claim lands in exactly one stage. That is the whole structural argument: a
|
||||
unit's `hi` and the site's `lo` are never both terms of the same `lo > hi`
|
||||
test, so SAFETY-25 §0a's cross-inverter contradiction - 0 W inside the billed
|
||||
quarter - is not something to guard against, it is something that cannot be
|
||||
written down.
|
||||
"""
|
||||
site_claims = [c for c in claims if c.actuator == ACTUATOR_SITE]
|
||||
if units is None:
|
||||
units = {c.actuator for c in claims if c.actuator != ACTUATOR_SITE}
|
||||
units = tuple(sorted(units))
|
||||
|
||||
# STAGE 1 - each unit's own claims become that unit's interval.
|
||||
bounds = {u: pre_resolve([c for c in claims if c.actuator == u])
|
||||
for u in units}
|
||||
|
||||
# STAGE 2 - the site claims become the grid target. At N=1 `site_claims` IS
|
||||
# `claims`, so this is the shipped arbiter on the shipped list.
|
||||
out = site_resolve(site_claims)
|
||||
|
||||
# STAGE 3 - the seam, and since ALLOC-01 the allocator behind it.
|
||||
#
|
||||
# ⚠️ THE ORDER MATTERS: `scope_violations()` IS COMPUTED BEFORE THE SPLIT,
|
||||
# NOT AFTER, because stage 3 consumes it. A claim filed on an actuator its
|
||||
# source's scope does not permit means the number about to be divided may
|
||||
# itself be wrong, and dividing a number that may be wrong is worse than
|
||||
# not dividing it - `allocator.plan()` carries the full argument, including
|
||||
# why the mis-routed claim is NOT promoted into somebody's envelope. This
|
||||
# was the open question ARB-03 left, and it is answered here rather than
|
||||
# left as a log line nothing grades.
|
||||
out.scope_errors = scope_violations(claims)
|
||||
out.unit_bounds = bounds
|
||||
out.shares, out.allocated, out.allocation = allocate_record(
|
||||
out.target_w, bounds, weights=weights, live=live,
|
||||
scope_errors=out.scope_errors, site_priority=out.winner_priority,
|
||||
tick=tick)
|
||||
return out
|
||||
|
||||
@@ -146,7 +146,7 @@ import math
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
from .arbiter import P_ARBITRAGE, Claim
|
||||
from .arbiter import ACTUATOR_SITE, P_ARBITRAGE, Claim
|
||||
from .price import Absence, price_option
|
||||
|
||||
_LOG = logging.getLogger("goodwe.arbitrage")
|
||||
@@ -425,5 +425,9 @@ def claim(decision: ArbitrageDecision) -> Claim | None:
|
||||
"""
|
||||
if not decision.trading or decision.power_w is None:
|
||||
return None
|
||||
# ⚠️ ON THE SITE ACTUATOR, EXPLICITLY. A trade is bought and sold at the
|
||||
# grid: the price is a property of the connection and the energy crosses the
|
||||
# meter. So this is a claim on the SITE target, which the allocator then
|
||||
# divides - not an instruction to any one pack.
|
||||
return Claim.set(SOURCE, P_ARBITRAGE, float(decision.power_w),
|
||||
decision.action)
|
||||
decision.action, actuator=ACTUATOR_SITE)
|
||||
|
||||
@@ -0,0 +1,339 @@
|
||||
"""SAFETY-31 - the power two inverters move through each other, which the meter cannot see.
|
||||
|
||||
Inverter A charging at 3 kW while inverter B discharges at 3 kW nets ~0 W at
|
||||
P1. The site looks idle. In reality 3 kW is going round a loop through two
|
||||
conversion stages continuously, for no benefit, and the wear on both packs is
|
||||
real even though every instrument in this add-on says nothing is happening.
|
||||
|
||||
WHY NOTHING EXISTING SEES IT, AND IT IS STRUCTURAL RATHER THAN AN OVERSIGHT
|
||||
==========================================================================
|
||||
Every consumer of the site measurement is a consumer of the NET. SAFETY-02's
|
||||
sign-disagreement watchdog gates on `abs(grid_w) > cfg.min_w` (300 W by
|
||||
default) - with the grid at ~0 that gate never opens, on any cycle, for any
|
||||
duration. The peak guard bills the quarter-hour average AT THE GRID
|
||||
CONNECTION. The capacity tariff bills grid exchange. `freeze.looks_frozen()`
|
||||
grades P1 against the site rail. There is one meter, it reads the sum, and
|
||||
circulating power is exactly the component of per-unit power that the sum
|
||||
DESTROYS. So this cannot be fixed by tuning a threshold on any existing
|
||||
detector; it needs a quantity none of them are computing.
|
||||
|
||||
THE QUANTITY
|
||||
============
|
||||
circulating_w = sum(|B_i|) - |sum(B_i)|
|
||||
|
||||
Zero when every unit pulls the same way - then sum(|B_i|) == |sum(B_i)| by the
|
||||
triangle equality. `2 * min(|B_a|, |B_b|)` at N=2 when they oppose, which is
|
||||
twice the power going round the loop and is the right scale: that is what both
|
||||
conversion stages are processing between them. It is non-negative always, it is
|
||||
zero at N<=1 identically, and it needs no threshold to be interpretable - the
|
||||
number IS the phenomenon in watts.
|
||||
|
||||
⚠️ IT IS COMPUTED FROM MEASURED PER-INVERTER POWER, AND THAT IS THE WHOLE CARD.
|
||||
=============================================================================
|
||||
The obvious cheap version reads the allocation record - the shares the
|
||||
allocator just handed out - and reports the same formula over those. It would
|
||||
be simpler, it would never see a `None`, and it would be worth NOTHING, for two
|
||||
independent reasons.
|
||||
|
||||
The first is that it cannot fire. ALLOC-01 shipped the sign-coherence gate as
|
||||
its AC 7 (`allocator.REFUSE_SIGN`, graded by `test_alloc.py` part 6): an
|
||||
allocation whose shares carry two signs is REFUSED, both units named, no shares
|
||||
returned. So a sensor over the allocation record is a sensor over a set the
|
||||
allocator has already guaranteed is sign-coherent. It reads zero by
|
||||
construction, forever, and a check written against it passes forever.
|
||||
|
||||
The second is the one MUTATION.md names as the third way a check lies. A sensor
|
||||
derived from the allocation record can only ever confirm THE ALLOCATOR AGREES
|
||||
WITH ITSELF. Every fault in this card's list is a divergence between what was
|
||||
commanded and what the hardware is doing:
|
||||
|
||||
* a unit ignoring or lagging its share;
|
||||
* a stale share still being executed by one inverter;
|
||||
* SAFETY-25's deferred loop floor, or a maintenance drain, pinning one unit
|
||||
while the loop drives the other;
|
||||
* an inverter doing something of its own accord - and THIS HARDWARE HAS DONE
|
||||
THAT TWICE. On 2026-09-02 the comms subsystem failed and the power stage
|
||||
went on executing its last instruction for 6 h 25 m (HW-01). Through all of
|
||||
it the allocation record was impeccable.
|
||||
|
||||
In every one of those the command side is coherent and the MEASUREMENT side is
|
||||
not. So the input is `Inverter.batt` - this unit's own power, read from its own
|
||||
`batt_entity`, which on the live system is holding register 0x0518, the
|
||||
inverter's own AC power. DEV-02 made that per-instance; before it there was one
|
||||
`batt` scalar on the Controller and this sensor could not have been written at
|
||||
all.
|
||||
|
||||
⚠️ AND THIS IS THE MEASUREMENT HALF OF A PAIR. ALLOC-01's gate is the COMMAND
|
||||
half: the allocator can no longer COMMAND circulating power. This module is the
|
||||
detection half: circulating power the allocator never commanded. Neither one
|
||||
replaces the other and neither is redundant - the gate refuses an allocation
|
||||
before it is written, and cannot see a millisecond past that; this reads the
|
||||
hardware and does not care what was written. Do not "unify" them.
|
||||
|
||||
THE TRIP, AND WHY A THRESHOLD ALONE IS A FALSE-ALARM GENERATOR
|
||||
==============================================================
|
||||
A momentary opposition is LEGITIMATE. Writes to the inverters are serialised
|
||||
(one `hass.call()` at a time - see `Inverter`'s docstring on what a hung write
|
||||
to A costs B), so on a cycle where the site target reverses, one unit receives
|
||||
its new command up to a whole control cycle before its sibling. Both then slew
|
||||
through zero, with a real ramp rate and a real first-order lag, and BETWEEN THE
|
||||
TWO ZERO CROSSINGS THE UNITS GENUINELY OPPOSE. Nothing is wrong; the site is
|
||||
turning around.
|
||||
|
||||
This project's doctrine on crying wolf is explicit (SAFETY-15, SAFETY-19) and
|
||||
this is exactly the shape that generates it. So the trip is a threshold AND a
|
||||
sustained window, and BOTH numbers were measured on the TEST-19 two-master rig
|
||||
rather than chosen - see `CIRC_OPTION_DEFAULTS` for the measurements and
|
||||
`DECISIONS/SAFETY-31-circulating-power.md` for the runs.
|
||||
|
||||
⚠️ THE WINDOW ACCUMULATES, WHICH IS WHY THIS IS NOT SAFETY-02's PROBLEM AGAIN.
|
||||
The reason the sign watchdog is blind to the broadcast fight is that the
|
||||
disagreement FLIPS SIGN on alternate ticks, so `disagree_since` is cleared
|
||||
between every pair of them and the 180 s hold never accumulates (allocator.py's
|
||||
docstring records the measurement). Circulating power cannot do that: it is a
|
||||
MAGNITUDE, non-negative by construction, and a sustained loop holds it high on
|
||||
every cycle rather than on every other one. An oscillation that genuinely
|
||||
alternated between opposing and agreeing is not a circulating loop and should
|
||||
not be reported as one.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
# CFG-03. THE ONE IN-CODE COPY OF THESE DEFAULTS. `config.yaml`'s `options:`
|
||||
# block is the source of truth an operator edits and the Supervisor reads;
|
||||
# `schema:` holds the bounds. This dict exists for the reason
|
||||
# `maintenance.MAINT_OPTION_DEFAULTS` does - the Dockerfile does not put
|
||||
# config.yaml in the image, so the running add-on cannot read it - and
|
||||
# `test_watchdog.py` pins the two together by READING config.yaml, so a drift
|
||||
# goes red in CI rather than shipping.
|
||||
CIRC_OPTION_DEFAULTS = {
|
||||
# --- THE THRESHOLD, AND IT IS READ OFF A CURVE ------------------------
|
||||
# ⚠️ MEASURED ON THE TEST-19 TWO-MASTER RIG, NOT CHOSEN. 924 closed-loop
|
||||
# runs in which NOTHING is faulty - every unit executes the share the
|
||||
# allocator gave it - over both families of stimulus that can produce
|
||||
# legitimate opposition: single reversals (7 sizes x 5 write staggers) and a
|
||||
# flapping load (7 periods x 4 amplitudes), each swept across the WHOLE
|
||||
# range config.yaml accepts for the two settings that decide how fast the
|
||||
# site can turn around, `gain` float(0.05,1.0) and `slew_w` int(50,5000).
|
||||
# The worst CONTINUOUS opposition, as a function of the threshold:
|
||||
#
|
||||
# 100 W -> 505.0 s 300 W -> 10.0 s 700 W -> 5.0 s
|
||||
# 200 W -> 445.0 s 350 W -> 10.0 s 1000 W -> 5.0 s
|
||||
# 250 W -> 40.0 s 400 W -> 5.0 s 1700 W -> 0.0 s
|
||||
#
|
||||
# THE KNEE IS AT 400 W and it is sharp. Below ~250 W a flapping load holds
|
||||
# the sensor above the threshold for MINUTES at a time - 505 s at 100 W -
|
||||
# and no window shorter than the 900 s billing quarter could tell that from
|
||||
# a fault. At 400 W and above the worst legitimate episode collapses to 5.0
|
||||
# s, ONE control cycle, and stays there. So this number is not a sensitivity
|
||||
# preference; it is the edge of the regime in which the guard is
|
||||
# answerable at all.
|
||||
#
|
||||
# 700 W is 1.75x the knee, and the margin is bought for one named reason:
|
||||
# INVERTER B DOES NOT PHYSICALLY EXIST. Its ramp and lag in the rig are
|
||||
# inverter A's, COPIED, carrying `measured=False` - SPIKE-04 measures the
|
||||
# real ones. A slower or faster second unit moves the transient's shape, and
|
||||
# the headroom above the knee is what absorbs that without re-opening this
|
||||
# card. Revisit it when SPIKE-04 lands, not before.
|
||||
#
|
||||
# What it costs: a circulating loop smaller than 350 W per unit is not
|
||||
# reported. That is deliberate - at that scale the round-trip loss is a few
|
||||
# watts and the wear is proportionate to it.
|
||||
"circulation_w": 700,
|
||||
|
||||
# --- THE WINDOW -------------------------------------------------------
|
||||
# Two lower bounds, one upper, and the chosen value clears all three.
|
||||
#
|
||||
# LOWER, from the rig: 5.0 s. The worst continuous legitimate opposition
|
||||
# above 700 W across all 924 runs is exactly one control cycle - a
|
||||
# reversing site whose second write lands a cycle after the first, which
|
||||
# is what the serialised write path does on every reversal.
|
||||
#
|
||||
# LOWER, from the firmware: `inverter.LINK_STALE_S`, 30 s. A unit still
|
||||
# executing a stale share for less than that is a LINK fault, and the
|
||||
# add-on already has an answer for it - liveness drops the unit and the
|
||||
# survivors carry its share, with the record saying so. Firing inside that
|
||||
# window would raise a second, louder alarm about a state that is already
|
||||
# being handled, which is the SAFETY-15/SAFETY-19 failure exactly.
|
||||
#
|
||||
# UPPER, from the bill: 900 s, the quarter that sets the capacity tariff.
|
||||
# A circulating loop must be caught and acted on well inside one.
|
||||
#
|
||||
# 75 s: fifteen control cycles - 15x the worst legitimate episode this rig
|
||||
# can produce, 2.5x the firmware's own veto window, and 12x inside the
|
||||
# quarter. ⚠️ IT IS DELIBERATELY NOT 60 OR 120. A round number here would be
|
||||
# a guess wearing a measurement's clothes, and the three bounds above are
|
||||
# what the number has to answer to.
|
||||
"circulation_hold_s": 75,
|
||||
}
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class CirculationConfig:
|
||||
"""Defaults, not constants - config.yaml carries both. See CFG-03 above."""
|
||||
|
||||
min_w: float = float(CIRC_OPTION_DEFAULTS["circulation_w"])
|
||||
hold_s: float = float(CIRC_OPTION_DEFAULTS["circulation_hold_s"])
|
||||
|
||||
|
||||
def circulating_w(powers):
|
||||
"""`sum(|B_i|) - |sum(B_i)|` over MEASURED per-inverter power, in W.
|
||||
|
||||
`powers` one measured power per inverter, in roster order, + = discharge.
|
||||
A unit whose reading did not arrive is `None`.
|
||||
|
||||
Returns a non-negative float, or `None` when the answer is unknown.
|
||||
|
||||
⚠️ N<=1 IS IDENTICALLY ZERO AND RETURNS ZERO EVEN FOR A MISSING READING
|
||||
(AC 5). With one term `sum(|B|) - |sum(B)| == |B| - |B| == 0` for EVERY
|
||||
value of B, including a value nobody read. Returning `None` there would be
|
||||
reporting an unknown where the algebra has no room for one, and it would put
|
||||
a shipped one-inverter install permanently in the "cannot tell" state on a
|
||||
quantity that cannot be anything but zero. Nothing changes at the shipped
|
||||
roster; that is the compatibility promise this card makes.
|
||||
|
||||
⚠️ AND AT N>=2 A MISSING READING IS `None`, NOT ZERO, WHICH IS THE OPPOSITE
|
||||
DIRECTION AND FOR A REASON. Zero would be this sensor reporting HEALTH from
|
||||
an absence - the precise shape of the 2026-09-02 outage, where a subsystem
|
||||
stopped answering and its silence read as calm for 6 h 25 m. An unknown
|
||||
circulating figure is an unknown, it CLEARS the trip's window rather than
|
||||
accumulating it (see `CirculationWatchdog.evaluate`), and the site is
|
||||
already stopped for a missing per-unit reading anyway - `inputs_ok` requires
|
||||
every unit's `batt`, and §11.1 rule 1 commands 0 W without consulting this.
|
||||
"""
|
||||
vals = list(powers)
|
||||
if len(vals) <= 1:
|
||||
return 0.0
|
||||
if any(v is None for v in vals):
|
||||
return None
|
||||
vals = [float(v) for v in vals]
|
||||
# ⚠️ max(0.0, ...) IS DEFENSIVE, AND IT IS AN EQUIVALENT MUTANT - SAID HERE
|
||||
# RATHER THAN LEFT FOR THE NEXT MUTATION SWEEP TO REDISCOVER. The triangle
|
||||
# inequality makes this non-negative mathematically, and in floating point
|
||||
# it is non-negative too: for a same-sign roster `abs(v)` is the list itself
|
||||
# up to one sign, so the two sums accumulate THE SAME MAGNITUDES IN THE SAME
|
||||
# ORDER and are bit-identical; for a mixed-sign roster the two differ by
|
||||
# 2*min(...), which is enormous beside any rounding. Searched, not assumed -
|
||||
# 700 000 random rosters of 2 to 12 units across 10 orders of magnitude
|
||||
# produced no negative result.
|
||||
#
|
||||
# So removing this line changes no observable and no check here would go
|
||||
# red. It stays because the cost is one call and the failure it would
|
||||
# prevent - a power sensor publishing -1e-16 W, which is the kind of value
|
||||
# somebody eventually writes a `< 0` branch against - is out of proportion
|
||||
# to it. Do not report its survival as a gap in the checks.
|
||||
return max(0.0, sum(abs(v) for v in vals) - abs(sum(vals)))
|
||||
|
||||
|
||||
def opposing(powers, min_w: float = 0.0):
|
||||
"""The units pulling each way right now, as `(discharging, charging)` names.
|
||||
|
||||
Indices, not names - the caller owns the roster order. Used for the operator
|
||||
sentence: "which two inverters are pushing against each other" is the first
|
||||
thing somebody woken by this alarm needs, and reconstructing it from the
|
||||
number alone is impossible.
|
||||
|
||||
`min_w` ignores units below a magnitude, so a unit resting at 3 W of
|
||||
standby draw is not named as a participant in a 3 kW loop.
|
||||
"""
|
||||
pos = [i for i, v in enumerate(powers)
|
||||
if v is not None and float(v) > float(min_w)]
|
||||
neg = [i for i, v in enumerate(powers)
|
||||
if v is not None and float(v) < -float(min_w)]
|
||||
return pos, neg
|
||||
|
||||
|
||||
class CirculationWatchdog:
|
||||
"""ONE PER SITE, evaluated once per control cycle.
|
||||
|
||||
⚠️ ONE PER SITE, WHERE SAFETY-02's IS ONE PER ACTUATOR, AND THE ASYMMETRY IS
|
||||
THE WHOLE ATTRIBUTION ARGUMENT. `SignWatchdog` concludes "THE UNIT I AM
|
||||
DRIVING is pushing power the wrong way" - evidence about one actuator, so
|
||||
the remedy is that actuator (arbiter.CLAIM_SCOPE calls `failsafe` a UNIT
|
||||
claim for exactly this reason). Circulating power is not a property any one
|
||||
inverter has. It is a property of a PAIR, it is defined by a sum across the
|
||||
roster, and there is no fact of the matter about which of the two is the
|
||||
offender: a unit ignoring its share and a sibling faithfully executing a
|
||||
share computed to sum with it produce identical readings. So the quantity is
|
||||
site-level, the watchdog is site-level, and the remedy below is site-level.
|
||||
|
||||
Latches, for `SignWatchdog`'s reason: the trip removes its own evidence. The
|
||||
moment the site stops commanding, the loop it detected either persists (a
|
||||
wedged unit, now visible at the meter) or vanishes (the add-on was one of
|
||||
the two participants) - and in the second case a non-latching detector would
|
||||
de-assert and start the whole thing again, three minutes at a time, forever.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: CirculationConfig | None = None, *,
|
||||
tripped: bool = False, reason: str = ""):
|
||||
self.cfg = cfg or CirculationConfig()
|
||||
self.over_since: datetime | None = None
|
||||
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED - SAFETY-34, and it is the
|
||||
# reason this card exists in the shape it does. `persistent_notification`
|
||||
# is IN MEMORY: Home Assistant restarts and the card is gone, with the
|
||||
# fault still running. That is precisely how the 2026-09-02 outage went
|
||||
# unseen for 6 h 25 m while the detector had been correct for hours. The
|
||||
# latch lives in `/data/state.json` - the add-on's only durable volume -
|
||||
# and `main.py` RE-RAISES the notification from it on every start.
|
||||
self.tripped = bool(tripped)
|
||||
self.reason = reason if self.tripped else ""
|
||||
# The worst figure seen during the current episode, for the operator
|
||||
# sentence. Not persisted: it is colour on a reason string that IS.
|
||||
self.peak_w = 0.0
|
||||
|
||||
def evaluate(self, circ_w, now: datetime) -> bool:
|
||||
"""Advance the detector one cycle. Returns True while tripped.
|
||||
|
||||
`circ_w` this cycle's `circulating_w()` over MEASURED per-unit power,
|
||||
or None when a reading is missing. None CLEARS the window
|
||||
rather than accumulating it - see the module docstring, and
|
||||
`SignWatchdog.evaluate` on the identical decision for a stale
|
||||
meter. A frozen figure held against a moving one manufactures
|
||||
a fault in about a window's worth of cycles.
|
||||
`now` the caller's clock, so this is testable and replayable.
|
||||
"""
|
||||
if self.tripped:
|
||||
# Latched. Do not re-evaluate: the trip removed the evidence.
|
||||
return True
|
||||
|
||||
if circ_w is None or float(circ_w) <= self.cfg.min_w:
|
||||
self.over_since = None
|
||||
self.peak_w = 0.0
|
||||
return False
|
||||
|
||||
circ_w = float(circ_w)
|
||||
self.peak_w = max(self.peak_w, circ_w)
|
||||
if self.over_since is None:
|
||||
self.over_since = now
|
||||
return False
|
||||
|
||||
held = (now - self.over_since).total_seconds()
|
||||
if held < self.cfg.hold_s:
|
||||
return False
|
||||
|
||||
self.tripped = True
|
||||
self.reason = (
|
||||
f"CIRCULATING_POWER: {circ_w:.0f} W measured going round between "
|
||||
f"the inverters (peak {self.peak_w:.0f} W) for {held:.0f} s "
|
||||
f"continuously - the meter cannot see it, because it nets to zero "
|
||||
f"there (limits: over {self.cfg.min_w:.0f} W, held over "
|
||||
f"{self.cfg.hold_s:.0f} s)")
|
||||
return True
|
||||
|
||||
def held_s(self, now: datetime) -> float:
|
||||
"""How long the current opposition has stood, for the status page.
|
||||
|
||||
Takes the clock rather than reading one, for `SignWatchdog.held_s`'s
|
||||
reason: every observable on this object is a pure function of what it
|
||||
was handed, and an unclocked function is one nothing can test.
|
||||
"""
|
||||
if self.over_since is None:
|
||||
return 0.0
|
||||
return (now - self.over_since).total_seconds()
|
||||
|
||||
def reset(self) -> None:
|
||||
self.over_since = None
|
||||
self.tripped = False
|
||||
self.reason = ""
|
||||
self.peak_w = 0.0
|
||||
@@ -0,0 +1,418 @@
|
||||
"""One inverter, as an OBJECT rather than as a set of Controller scalars.
|
||||
|
||||
WHAT THIS FIXES, in one sentence: every piece of per-device state in this
|
||||
add-on used to be a single scalar on the Controller, and several of those
|
||||
scalars are SAFETY INPUTS - so a second inverter would have been graded against
|
||||
the first one's numbers.
|
||||
|
||||
The scalars, and what each one was silently asserting:
|
||||
|
||||
`dev_min` / `dev_max` ONE pair, read from ONE `setpoint_entity`. A second
|
||||
inverter's rating was never read at all, so its clamp,
|
||||
its freeze rail and the peak guard's `achievable_w`
|
||||
were all inverter A's.
|
||||
`soc` ONE state of charge into the maintenance FSM,
|
||||
SAFETY-24's pack floor and arbitrage's bounds. An
|
||||
average lets the emptier pack be driven below its own
|
||||
floor; a maximum parks the fuller one.
|
||||
`batt` ONE battery power into the anti-windup saturation
|
||||
detector - see the SITE/UNIT note at the bottom of
|
||||
this docstring, because this one goes the OTHER WAY.
|
||||
`sign_wd` ONE SignWatchdog, whose own docstring says "one
|
||||
instance per actuator", latched under FLAT store keys.
|
||||
A trip caused by B latched A across restarts and one
|
||||
operator action cleared both.
|
||||
`last_write` ONE write bookkeeping, and ONE serialised `hass.call()`
|
||||
behind it: a hung write to A ate B's 30 s layer-1
|
||||
budget.
|
||||
|
||||
⚠️ WHAT IS DELIBERATELY *NOT* HERE, AND IT IS THE HALF THAT IS EASY TO GET
|
||||
BACKWARDS. THERE IS NO `Tuning` ON THIS OBJECT AND THERE IS NO INTEGRATOR.
|
||||
§6.2 and ALLOC-01's stability argument are ONE integrator on P1, ABOVE the
|
||||
split: the site target S is divided into per-unit shares, so the gain seen at
|
||||
the meter is a CONVEX COMBINATION of the per-unit gains and a bad split cannot
|
||||
destabilise the site. Give each inverter its own `Tuning` and somebody will
|
||||
eventually call `compute()` with it, and the moment two integrators regulate
|
||||
one meter the whole argument is gone - that is the two-writers failure the
|
||||
arbiter exists to prevent, one level up.
|
||||
|
||||
The one field of `Tuning` that genuinely IS per-device is `max_w`, the
|
||||
supervised cap on what may be WRITTEN to one setpoint entity (§11.3), and it is
|
||||
here as `max_w`. The SITE `Tuning` the loop runs on takes its bound from the
|
||||
roster - `sum(inv.max_w)` - so at N=1 it is byte-identical to the shipped
|
||||
number and at N>=2 it is what the site can actually deliver. That is the whole
|
||||
of "the rating stops being a scalar"; a per-unit Tuning would be three more
|
||||
numbers nobody reads and one more place a limit has to be kept in step (CFG-03
|
||||
already tracks three).
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
SITE OR UNIT? THE TWO HALVES OF THE N=1 IDENTITY, AND THEY MOVE IN OPPOSITE
|
||||
DIRECTIONS
|
||||
|
||||
At N=1 §6.2's identity holds: the fabricated grid reading and the battery
|
||||
setpoint are the same number, so "the site" and "the inverter" are the same
|
||||
thing and every scalar above was RIGHT. Splitting them is not one change, it is
|
||||
two, and they point opposite ways:
|
||||
|
||||
COMMANDING becomes per-unit. One setpoint entity per inverter, one rating,
|
||||
one clamp, one watchdog, one heartbeat.
|
||||
SENSING, for the loop, becomes SITE. `compute()` regulates the METER. Its
|
||||
`actual_w` is the anti-windup input to
|
||||
`abs(prev_w - actual_w) > saturation_w`, where
|
||||
`prev_w` is the SITE target. Feed it ONE unit's
|
||||
power at a roster of two and that test compares
|
||||
a site number against a unit number, trips the
|
||||
freeze permanently and leaves a standing grid
|
||||
error.
|
||||
|
||||
That second half is MEASURED, not argued. On admin/goodwe's two-master rig
|
||||
(`tools/alloc_sim.py --splits --feedback unit`), with the loop fed one
|
||||
inverter's power the aggregate trace at the meter becomes a function of the
|
||||
split - up to 510 W apart at gain 0.2, 250 W at gain 0.4, 50 W at gain 0.6 -
|
||||
while the allocator's shares sum to S in every one of those runs. The
|
||||
counterfactual is the proof: change that ONE input to the site total and every
|
||||
split is bit-identical at every gain the schema accepts. ALLOC-01's review
|
||||
isolated it and test_alloc.py part 8 graded it as a disclosed defect waiting on
|
||||
this card.
|
||||
|
||||
So this object owns `batt` - THIS inverter's own power, which is what a
|
||||
per-unit consumer needs - and the Controller sums them into the site figure the
|
||||
loop is fed. Getting that backwards reintroduces the divergence.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
LIVENESS, AND WHY IT IS A METHOD WITH A REASON
|
||||
|
||||
`Controller.live_units()` decides which inverters may be commanded this tick,
|
||||
and `allocator.plan()` DROPS what it does not list - the survivors then carry
|
||||
the whole site target. A wrong answer there is a real change in what the site
|
||||
can deliver, so `is_live()` answers one question and says which: CAN THIS
|
||||
CONTROLLER PUT A NUMBER ON THIS INVERTER RIGHT NOW.
|
||||
|
||||
ONE way it cannot, and exactly one: every write has been REJECTED for a whole
|
||||
`LINK_STALE_S` window. Not one rejection - `hass.set_number()` returns False for
|
||||
a transient 400 as readily as for a device that has gone - but a continuous run
|
||||
of them with no acceptance in between.
|
||||
|
||||
⚠️ AND NOT "IT HAS NO `setpoint_entity`", THOUGH THAT IS ALSO A UNIT THIS
|
||||
CONTROLLER CANNOT COMMAND. The two look the same and want opposite answers. A
|
||||
link that WAS working and stopped is an event: the survivors carry its share,
|
||||
the record says so, and the site goes on running at reduced strength, which is
|
||||
the best available outcome. A roster entry with no writer configured at all is a
|
||||
CONFIGURATION that cannot be delivered - it was never reachable, nothing has
|
||||
gone wrong on the wire, and quietly running the site at part strength on a
|
||||
roster somebody wrote down wrong is how a half-driven site reads as healthy on
|
||||
every dashboard. That one belongs to main.py's refusal branch, which commands
|
||||
0 W and NAMES the inverter; putting it here would absorb it into the ordinary
|
||||
drop and delete the last trigger that branch has. See `Controller.cycle()`.
|
||||
|
||||
⚠️ AND NOT "ITS SENSORS ARE MISSING" EITHER. A pack whose SoC did not answer is
|
||||
a third fault with a third remedy: `inputs_ok` already stops the whole site at
|
||||
P_SAFETY for that, and dropping the unit from the SPLIT instead would hand its
|
||||
share to a sibling while the site kept regulating - the opposite of what a
|
||||
missing measurement should cause. Liveness is about the WRITE PATH, and only
|
||||
about a write path that has stopped answering.
|
||||
"""
|
||||
|
||||
import math
|
||||
from datetime import datetime
|
||||
|
||||
from .clamp import ClampResult
|
||||
from .store import unit_key
|
||||
from .watchdog import SignWatchdog, SignWatchdogConfig
|
||||
|
||||
# How long every write to one inverter must have been REJECTED before this
|
||||
# controller stops claiming it can command it.
|
||||
#
|
||||
# ⚠️ IT IS LAYER 1'S OWN WINDOW, NOT A NEW OPINION ABOUT LINKS. The ESP32
|
||||
# commands 0 W and keeps commanding it after ~30 s without a refresh
|
||||
# (`validate.FIRMWARE_INGEST_VETO_S`), so a link this controller has not been
|
||||
# able to write for a whole 30 s is a link the hardware is about to take away
|
||||
# from it anyway. Claiming it as commandable past that point is the add-on
|
||||
# telling the allocator it can deliver watts that the firmware has already
|
||||
# decided it will not. No config key: CFG-03 tracks three places a default has
|
||||
# to be kept in step and this does not earn a fourth - it is derived from a
|
||||
# constant the firmware and validate.py already share.
|
||||
LINK_STALE_S = 30.0
|
||||
|
||||
# The name of the inverter a SINGLE-INVERTER config describes. ⚠️ A NAME, NOT A
|
||||
# CONFIGURATION - it exists so that a per-inverter claim has an actuator to be
|
||||
# filed ON, which is what makes the site/unit split something a check can grade
|
||||
# rather than a comment. It lives here rather than in main.py now that the
|
||||
# roster does.
|
||||
#
|
||||
# ⚠️ CFG-04 DID NOT MAKE THIS "THE FIRST ONE". It is the name the flat-keys path
|
||||
# gives its one unit, and nothing else; a declared `inverters:` roster names its
|
||||
# own entries and this constant is not consulted. The store migration
|
||||
# (`migrate_unit_keys`) still targets it, because the flat pre-DEV-02 keys can
|
||||
# only ever have belonged to a single-inverter install.
|
||||
UNIT_A = "inverter-a"
|
||||
|
||||
# The per-unit keys this object keeps in the Store, namespaced by unit name.
|
||||
# ⚠️ THE VALUES ARE THE PRE-DEV-02 FLAT KEY NAMES, and that is what makes the
|
||||
# migration mechanical rather than transcribed: `store.migrate_unit_keys()`
|
||||
# reads this same mapping, so a key renamed here cannot silently stop being
|
||||
# migrated. See store.py.
|
||||
UNIT_STORE_KEYS = ("sign_tripped", "sign_reason")
|
||||
|
||||
|
||||
class Inverter:
|
||||
"""ONE inverter: its entities, its rating, its watchdogs, its store keys.
|
||||
|
||||
Constructed once per configured inverter and held in `Controller.inverters`.
|
||||
Everything on it is about THIS device; nothing on it is about the site.
|
||||
|
||||
⚠️ `hass` IS NOT A CONSTRUCTOR ARGUMENT. This object is built in
|
||||
`Controller.__init__`, which runs before any I/O and, in four existing
|
||||
checks, with `hass=None` entirely. The device range is read LATER, by
|
||||
`Controller.run_control()`, from THIS unit's own `setpoint_entity` - which
|
||||
is the whole of "each instance's rating is read from its own entity".
|
||||
"""
|
||||
|
||||
def __init__(self, name, *, setpoint_entity="", soc_entity="",
|
||||
batt_entity="", batt_invert=False, max_w=2000.0,
|
||||
store=None, sign_cfg=None):
|
||||
self.name = str(name)
|
||||
self.setpoint_entity = str(setpoint_entity or "")
|
||||
self.soc_entity = str(soc_entity or "")
|
||||
self.batt_entity = str(batt_entity or "")
|
||||
self.batt_invert = bool(batt_invert)
|
||||
# The supervised cap on what may be written to THIS setpoint entity.
|
||||
# See the module docstring on why this is a number and not a `Tuning`.
|
||||
self.max_w = float(max_w)
|
||||
|
||||
# --- the device's own reported range, read from its own entity -------
|
||||
# None until `hass.limits()` has answered. NOT guessed at: ESPHome is
|
||||
# often not up when the add-on boots, and (None, None) is the honest
|
||||
# report that the range checks were skipped rather than invented.
|
||||
self.dev_min = None
|
||||
self.dev_max = None
|
||||
|
||||
# --- this unit's own measurements ------------------------------------
|
||||
self.soc = None
|
||||
self.batt = None
|
||||
|
||||
# --- what this unit was last told, and what it last accepted ---------
|
||||
# `target` is THIS unit's share of the site target from the last
|
||||
# resolution - the number its heartbeat re-emits and the number
|
||||
# SAFETY-02 grades against the meter. At N=1 it IS the site target,
|
||||
# because the allocator is a pass-through there.
|
||||
self.target = 0.0
|
||||
self.last_write = None
|
||||
self.last_write_at = None
|
||||
self.last_write_ok = None
|
||||
# ⚠️ TWO TIMESTAMPS, NOT ONE FLAG. `last_write_ok` is the last write's
|
||||
# verdict and it flips on a single transient 400; liveness needs a RUN
|
||||
# of rejections, so `rejected_since` records when the current run
|
||||
# started and is cleared by any acceptance.
|
||||
self.rejected_since = None
|
||||
# The heartbeat's own deadline, on the event loop's monotonic clock.
|
||||
# ⚠️ PER UNIT, WHICH IS THE WHOLE OF AC 6. One shared `last_beat` and
|
||||
# one serialised write meant a hung call to A pushed B's refresh past
|
||||
# layer 1's ~30 s veto - i.e. one inverter's transport fault zeroing a
|
||||
# healthy sibling. Starts at 0.0, which is what the single scalar did.
|
||||
self.last_beat = 0.0
|
||||
|
||||
# --- SAFETY-03's per-write evidence ----------------------------------
|
||||
# What THIS unit's last write clamped, or None before it has run. The
|
||||
# ALARM (`ClampWatchdog`) stays one per controller - clamp.py says so in
|
||||
# its own docstring, and it is an anti-flood counter over an event bus
|
||||
# rather than a property of a device - but the EVIDENCE is per unit,
|
||||
# because a clamp on B says nothing about A.
|
||||
self.clamp_last: ClampResult | None = None
|
||||
|
||||
# --- SAFETY-02, one instance per actuator, under NAMESPACED keys -----
|
||||
# ⚠️ THE WATCHDOG'S OWN DOCSTRING SAID "one instance per actuator" WHILE
|
||||
# THE CONTROLLER HELD EXACTLY ONE. Restored from THIS unit's own keys,
|
||||
# so a trip caused by B latches B and leaves A commanding - and an
|
||||
# operator clearing one does not silently clear the other.
|
||||
self.store = store
|
||||
data = getattr(store, "data", {}) if store is not None else {}
|
||||
self.sign_wd = SignWatchdog(
|
||||
sign_cfg or SignWatchdogConfig(),
|
||||
tripped=bool(data.get(self.key("sign_tripped"), False)),
|
||||
reason=str(data.get(self.key("sign_reason"), "") or ""))
|
||||
|
||||
# -- store ---------------------------------------------------------------
|
||||
def key(self, name: str) -> str:
|
||||
"""This unit's namespaced Store key for `name`. See store.unit_key()."""
|
||||
return unit_key(self.name, name)
|
||||
|
||||
def store_set(self, name: str, value) -> None:
|
||||
if self.store is not None:
|
||||
self.store.set(self.key(name), value)
|
||||
|
||||
# -- the numbers other modules ask this object for -----------------------
|
||||
def rating_w(self) -> float:
|
||||
"""The largest magnitude this unit can be commanded, in W.
|
||||
|
||||
`min(max_w, |dev_min|, |dev_max|)` - the supervised cap and whatever the
|
||||
device itself reports, whichever is smaller. It is the same conjunction
|
||||
`freeze.rail_ceiling_w()` computes for the freeze rail and the same one
|
||||
main.py hands the peak guard as `achievable_w`, which is why it is
|
||||
written once here: three transcriptions of a rating is three chances for
|
||||
inverter B to be graded against inverter A's number.
|
||||
|
||||
A bound that could not be read is SKIPPED, not treated as zero: (None,
|
||||
None) means ESPHome was not up, and answering 0 W there would say this
|
||||
inverter can do nothing.
|
||||
"""
|
||||
out = abs(float(self.max_w))
|
||||
for bound in (self.dev_min, self.dev_max):
|
||||
if bound is not None and math.isfinite(float(bound)):
|
||||
out = min(out, abs(float(bound)))
|
||||
return out
|
||||
|
||||
def has_writer(self) -> bool:
|
||||
return bool(self.setpoint_entity)
|
||||
|
||||
# -- liveness ------------------------------------------------------------
|
||||
def note_write(self, ok: bool, now: datetime) -> None:
|
||||
"""Record one write's verdict. The only thing that moves liveness."""
|
||||
self.last_write_ok = bool(ok)
|
||||
if ok:
|
||||
self.rejected_since = None
|
||||
elif self.rejected_since is None:
|
||||
self.rejected_since = now
|
||||
|
||||
def is_live(self, now: datetime, stale_s: float = LINK_STALE_S):
|
||||
"""`(live, why_not)` - may this controller command this unit THIS TICK?
|
||||
|
||||
Read the module docstring before widening this - in particular on why a
|
||||
unit with NO `setpoint_entity` is deliberately still "live" here and is
|
||||
refused one layer up instead. The allocator DROPS what `live_units()`
|
||||
does not list and the survivors carry the whole site target, so a false
|
||||
"not live" is a site target divided among fewer inverters than exist -
|
||||
and at a roster of one it is the allocator refusing outright and the
|
||||
site commanding 0 W.
|
||||
|
||||
⚠️ ANSWERED PER TICK, NEVER CACHED, for `allocator.plan()`'s reason: a
|
||||
link goes stale between one cycle and the next.
|
||||
"""
|
||||
if self.rejected_since is not None:
|
||||
held = (now - self.rejected_since).total_seconds()
|
||||
if held >= float(stale_s):
|
||||
return False, (f"every write rejected for {held:.0f} s "
|
||||
f"(limit {float(stale_s):.0f} s)")
|
||||
return True, ""
|
||||
|
||||
def link_note(self, now: datetime) -> str:
|
||||
"""One line for the status page. Empty when there is nothing to say."""
|
||||
if not self.has_writer():
|
||||
return (f"{self.name}: NO SETPOINT ENTITY - this controller cannot "
|
||||
f"command it, and the site refuses rather than running at "
|
||||
f"part strength")
|
||||
live, why = self.is_live(now)
|
||||
if not live:
|
||||
return f"{self.name}: NOT COMMANDABLE - {why}"
|
||||
if self.rejected_since is not None:
|
||||
held = (now - self.rejected_since).total_seconds()
|
||||
return (f"{self.name}: writes rejected for {held:.0f} s - still "
|
||||
f"commandable until {LINK_STALE_S:.0f} s")
|
||||
return ""
|
||||
|
||||
def __repr__(self) -> str:
|
||||
return (f"<Inverter {self.name} sp={self.setpoint_entity!r} "
|
||||
f"max_w={self.max_w:.0f} dev=({self.dev_min}, {self.dev_max})>")
|
||||
|
||||
|
||||
def roster_entries(opts: dict) -> list:
|
||||
"""The `inverters:` option, normalised to a list of dicts. Never None.
|
||||
|
||||
Separate from `build_roster()` because validate.py needs to grade the SAME
|
||||
list this builds from, and a second transcription of "what counts as an
|
||||
entry" is a second answer to it. A non-list, or a list with non-dict
|
||||
members, comes back as it was so the validator can name what it found -
|
||||
dropping the junk here would hand the validator a clean list and a config
|
||||
nobody refused.
|
||||
"""
|
||||
entries = opts.get("inverters")
|
||||
if entries is None or entries == "":
|
||||
return []
|
||||
if not isinstance(entries, (list, tuple)):
|
||||
return [entries]
|
||||
return list(entries)
|
||||
|
||||
|
||||
def build_roster(opts: dict, store, sign_cfg=None) -> list:
|
||||
"""The site's inverters, in roster order.
|
||||
|
||||
TWO SHAPES, AND WHICH ONE IS IN FORCE IS DECIDED BY ONE TEST: is
|
||||
`inverters:` empty?
|
||||
|
||||
EMPTY the five flat keys - `setpoint_entity`, `soc_entity`,
|
||||
`batt_entity`, `batt_invert`, `max_w` - describe the ONE inverter,
|
||||
exactly as the shipped scalars did. This is what every install
|
||||
that upgrades into this version reads, without an operator
|
||||
touching anything, and it is byte-identical to what DEV-02
|
||||
shipped. config.yaml's default is `[]` for precisely that reason,
|
||||
and Supervisor 2026.08.0 refuses the whole options blob without
|
||||
it - see the options-block note on `inverters:`.
|
||||
|
||||
NON-EMPTY each entry describes one inverter and the flat keys describe
|
||||
none of them. ⚠️ NOTHING IS INHERITED. An entry that omits
|
||||
`soc_entity` has no SoC sensor; it does NOT borrow the flat one,
|
||||
because "this unit's number came from somewhere else" is the
|
||||
defect DEV-02 spent a card removing and a fallback here would
|
||||
rebuild it in three lines. `name`, `setpoint_entity` and `max_w`
|
||||
are required of every entry - the schema enforces it on the
|
||||
Supervisor path, `validate.py` rule 9 enforces it for sim/inject.py
|
||||
and the checks, which reach this function with any dict at all.
|
||||
|
||||
⚠️ THIS FUNCTION REFUSES NOTHING, AND THAT IS ON PURPOSE. A refusal here
|
||||
happens inside `Controller.__init__`, before the startup gate has run and
|
||||
before anything can render the reason to an operator; validate.py's rule 9
|
||||
is the place that says no, with a message, through `refuse()`. So this
|
||||
builds the most honest roster it can out of whatever it was handed - a
|
||||
missing name becomes a positional one, a missing rating becomes 0.0 W - and
|
||||
every one of those states is something rule 9 has already refused by the
|
||||
time a control loop exists. Keep the two in step: a shape this tolerates
|
||||
that rule 9 does not name is a shape that runs.
|
||||
"""
|
||||
entries = roster_entries(opts)
|
||||
if not entries:
|
||||
# ⚠️ THE UNCHANGED PATH. Same name, same entities, same rating, same
|
||||
# store keys as before CFG-04 - an install that upgrades reads
|
||||
# identically, which is AC 3.
|
||||
return [Inverter(
|
||||
UNIT_A,
|
||||
setpoint_entity=opts.get("setpoint_entity", ""),
|
||||
soc_entity=opts.get("soc_entity", ""),
|
||||
batt_entity=opts.get("batt_entity", ""),
|
||||
batt_invert=bool(opts.get("batt_invert")),
|
||||
max_w=float(opts.get("max_w", 2000)),
|
||||
store=store, sign_cfg=sign_cfg)]
|
||||
|
||||
roster = []
|
||||
for i, entry in enumerate(entries):
|
||||
entry = entry if isinstance(entry, dict) else {}
|
||||
# ⚠️ THE FALLBACK NAME IS POSITIONAL, NOT `UNIT_A`. Two nameless entries
|
||||
# both called `inverter-a` would share one Store namespace, so one
|
||||
# unit's SAFETY-02 latch would be the other's - a fault on B latching A
|
||||
# is the exact failure DEV-02's namespaced keys removed. Rule 9 refuses
|
||||
# a nameless entry outright; this only decides what the refusal is
|
||||
# allowed to call it in the meantime.
|
||||
name = str(entry.get("name") or "").strip() or f"inverter-{i + 1}"
|
||||
roster.append(Inverter(
|
||||
name,
|
||||
setpoint_entity=entry.get("setpoint_entity", ""),
|
||||
soc_entity=entry.get("soc_entity", ""),
|
||||
batt_entity=entry.get("batt_entity", ""),
|
||||
batt_invert=bool(entry.get("batt_invert")),
|
||||
# ⚠️ NOT `opts["max_w"]`. See the docstring: a rating an entry did
|
||||
# not state is not the flat one, it is a rating rule 9 refuses.
|
||||
max_w=_entry_max_w(entry),
|
||||
store=store, sign_cfg=sign_cfg))
|
||||
return roster
|
||||
|
||||
|
||||
def _entry_max_w(entry: dict) -> float:
|
||||
"""One entry's supervised cap, or 0.0 when it did not state a usable one.
|
||||
|
||||
0.0 rather than a borrowed number, and rather than an exception: rule 9
|
||||
refuses `max_w` missing or unparseable by name, and a roster that cannot be
|
||||
built at all would refuse it with a traceback instead.
|
||||
"""
|
||||
try:
|
||||
return float(entry.get("max_w"))
|
||||
except (TypeError, ValueError):
|
||||
return 0.0
|
||||
+2250
-250
File diff suppressed because it is too large
Load Diff
@@ -18,16 +18,47 @@ OWNERSHIP, not priority. Exactly one thing writes the setpoint at any moment:
|
||||
The loop is never "disabled" - it yields. The heartbeat to the inverter keeps
|
||||
running in every phase, so the hardware watchdog stays fed and a crash here
|
||||
still ends with the inverter at 0 W rather than latched.
|
||||
|
||||
ONE PACK AT A TIME (MAINT-05). There is now one `Maintenance` per roster entry,
|
||||
each with its own schedule, its own phase and its own history under its own
|
||||
Store keys - and therefore, for the first time, two of them able to move power
|
||||
on ONE grid connection at once. Read `arbitrate()` before touching any of it:
|
||||
the site holds exactly ONE maintenance slot, a pack that is not IDLE holds it,
|
||||
and every other pack is held at IDLE under the loop until it is released. That
|
||||
is not a scheduling nicety. A drain of pack A against a charge of pack B is two
|
||||
power-moving phases pulling opposite ways across the meter - the circulating
|
||||
power SAFETY-31 exists to DETECT, arriving here as something this module can
|
||||
simply not do.
|
||||
"""
|
||||
|
||||
import logging
|
||||
import math
|
||||
from dataclasses import dataclass, field
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from .store import MAINT_UNIT_KEYS, unit_key
|
||||
|
||||
_LOG = logging.getLogger("goodwe.maint")
|
||||
|
||||
IDLE, DRAIN, CHARGE, HOLD = "idle", "drain", "charge", "hold"
|
||||
|
||||
# ⚠️ THE PHASES THAT MOVE POWER, WHICH IS NOT THE SAME LIST AS "owns the
|
||||
# setpoint". The table above is about WHO WRITES the number; this is about
|
||||
# whether the pack is being pushed. DRAIN and HOLD own the setpoint. CHARGE does
|
||||
# NOT - the loop owns it - and CHARGE is in here anyway, because the charge-only
|
||||
# clamp plus the cheap-window floor is what pulls a second pack full while the
|
||||
# first is being emptied. Leaving CHARGE out is precisely the interlock hole
|
||||
# this card is about: pack A charging from the grid at 2000 W while pack B
|
||||
# drains 2000 W to export is 4 kW going round in a circle with the meter at
|
||||
# zero, and both packs believing they are behaving.
|
||||
#
|
||||
# HOLD commands 0 W and moves nothing, and it is in here for the other half of
|
||||
# the sentence: it OWNS the actuator - the pack is parked at the top for the BMS
|
||||
# and is deliberately not available to the loop - so a second cycle starting
|
||||
# under it would still be two recalibrations at once, which is the thing whose
|
||||
# value is a clean uninterrupted coulomb count.
|
||||
POWER_MOVING = (DRAIN, CHARGE, HOLD)
|
||||
|
||||
# A drain of a 13.8 kWh usable pack (300 Ah x 51.2 V, DoD 90) at the shipped
|
||||
# 2000 W is ~6.9 h even with no house load helping - and less in practice, since
|
||||
# house load drains alongside the export and soc_floor stops short of empty.
|
||||
@@ -153,17 +184,102 @@ class MaintResult:
|
||||
setpoint_w: float | None = None
|
||||
charge_only: bool = False
|
||||
events: list = field(default_factory=list)
|
||||
# ⚠️ WHY A DEFERRAL IS A FIELD AND NOT JUST A LOG LINE. A pack that is due
|
||||
# and is not starting looks, from every surface an operator has, exactly
|
||||
# like a pack whose schedule has quietly stopped firing - §12's opening
|
||||
# sentence, the failure this whole module exists because of. It is carried
|
||||
# so the status page can SAY "waiting for the other pack" rather than
|
||||
# showing an idle machine and a due date in the past. Empty on every path
|
||||
# that is not deferring, so a roster of one never sees it.
|
||||
deferred: str = ""
|
||||
|
||||
|
||||
class UnitHistory:
|
||||
"""One pack's maintenance history in the Store, under one spelling.
|
||||
|
||||
⚠️ THE NAMESPACE IS A CONSTRUCTOR ARGUMENT AND `None` IS A REAL VALUE, NOT
|
||||
AN OMISSION. `unit=None` means the FLAT keys - `phase`, `phase_started`,
|
||||
`last_completed`, `last_start_attempt` - which is what every install has
|
||||
written since the add-on shipped and what a one-inverter site keeps writing
|
||||
after MAINT-05. §6.2's identity: with one pack there is nothing for a
|
||||
namespace to distinguish it FROM, and adding one would change the layout of
|
||||
a live state file to say something it already said. `arbiter.actuator_for()`
|
||||
makes the same move for the same reason and its docstring argues it.
|
||||
|
||||
⚠️ `mirror_flat` IS THE ROLLBACK VIEW AND IT IS ONLY EVER THE FIRST PACK'S.
|
||||
At N>=2 pack A's history has been migrated into its namespace and is written
|
||||
there; the flat keys are ALSO kept in step, so an operator who rolls the
|
||||
add-on back to a single-FSM version finds a CURRENT history rather than one
|
||||
dated the day the second inverter was declared. store.migrate_maint_keys()
|
||||
carries the argument, and it is DEV-02's rule 2 applied to history instead
|
||||
of to a latch: "left in the file" is not the same promise as "still true".
|
||||
Pack B has no flat spelling to mirror to - the flat keys mean pack A on
|
||||
every install that has them - so it is constructed with mirroring off, and
|
||||
a mirror from B would OVERWRITE A's rollback view with B's phase.
|
||||
"""
|
||||
|
||||
def __init__(self, store, unit: str | None = None, mirror_flat: bool = False):
|
||||
self.store = store
|
||||
self.unit = unit
|
||||
self.mirror_flat = bool(mirror_flat)
|
||||
|
||||
def key(self, name: str) -> str:
|
||||
"""The Store key this pack's `name` lives under."""
|
||||
return name if self.unit is None else unit_key(self.unit, name)
|
||||
|
||||
def get(self, name: str, default=None):
|
||||
return getattr(self.store, "data", {}).get(self.key(name), default)
|
||||
|
||||
def set(self, name: str, value) -> None:
|
||||
self.store.set(self.key(name), value)
|
||||
if self.mirror_flat:
|
||||
self.store.set(name, value)
|
||||
|
||||
def get_time(self, name: str):
|
||||
return self.store.get_time(self.key(name))
|
||||
|
||||
def set_time(self, name: str, when) -> None:
|
||||
self.store.set_time(self.key(name), when)
|
||||
if self.mirror_flat:
|
||||
self.store.set_time(name, when)
|
||||
|
||||
|
||||
class Maintenance:
|
||||
def __init__(self, cfg: MaintConfig, store):
|
||||
"""ONE pack's recalibration cycle: its schedule, its phase, its history.
|
||||
|
||||
⚠️ ONE PER ROSTER ENTRY SINCE MAINT-05, AND THE SLOT IS NOT ITS OWN. This
|
||||
object decides WHEN ITS PACK would like to start; `arbitrate()` decides
|
||||
which of them may, because the constraint is a property of the grid
|
||||
connection and no single FSM can see it. Never call `tick()` in a loop
|
||||
without passing the `blocked_by` that `arbitrate()` returned for it: that is
|
||||
the two-packs-at-once bug with the interlock present but not wired.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: MaintConfig, store, unit: str | None = None,
|
||||
name: str = "", mirror_flat: bool = False):
|
||||
self.cfg = cfg
|
||||
self.store = store
|
||||
# ⚠️ `self.store` IS THE VIEW, NOT THE Store. Everything in this class
|
||||
# names an UNQUALIFIED key - "phase", "last_completed" - and the view is
|
||||
# the one place that turns it into the key this pack owns. A raw
|
||||
# `store.set("phase", ...)` anywhere below would write pack A's history
|
||||
# from pack B's state machine, which is the shared-state bug this card
|
||||
# is about, and there would be nothing to see at a roster of one.
|
||||
self.store = UnitHistory(store, unit, mirror_flat)
|
||||
self.unit = unit
|
||||
# What an event or a refusal calls this pack. At a roster of one it is
|
||||
# never rendered - a single machine cannot be deferred - so the shipped
|
||||
# one-inverter reason strings are untouched.
|
||||
self.name = str(name or unit or "the pack")
|
||||
# Edge-memo for the deferral note. The action log holds 40 lines and a
|
||||
# deferral lasts as long as the other pack's cycle - hours - so a line
|
||||
# per cycle would flush the very context that explains it. Same pattern
|
||||
# as `Controller._arb_action` and `_maint_shape_suspended`.
|
||||
self._deferred = ""
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
def phase(self) -> str:
|
||||
return self.store.data.get("phase", IDLE)
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self.store.set("phase", phase)
|
||||
@@ -185,14 +301,60 @@ class Maintenance:
|
||||
last = self.store.get_time("last_completed")
|
||||
return None if last is None else last + timedelta(days=self.cfg.interval_days)
|
||||
|
||||
def waited_days(self, now: datetime) -> float:
|
||||
"""Days since this pack last COMPLETED a cycle; `inf` if it never has.
|
||||
|
||||
⚠️ THE ARBITRATION KEY, AND IT IS DELIBERATELY NOT `due()`. `due()` is a
|
||||
yes/no and two packs that are both due are indistinguishable by it -
|
||||
which is how a roster-order tie-break gets written and how the first
|
||||
entry then wins every contested month forever while the second drifts.
|
||||
This is an ORDERING: the pack whose coulomb counter has gone longest
|
||||
without a recalibration goes first. `inf` for never-recalibrated is the
|
||||
same statement `due()` makes about an absent `last_completed`, kept as
|
||||
one so a fresh pack cannot lose to one that ran last month.
|
||||
"""
|
||||
last = self.store.get_time("last_completed")
|
||||
return math.inf if last is None else (now - last).total_seconds() / 86400.0
|
||||
|
||||
def _cooled(self, now: datetime) -> bool:
|
||||
"""Is the post-abort cooldown over?"""
|
||||
last_try = self.store.get_time("last_start_attempt")
|
||||
return (last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN))
|
||||
|
||||
def wants_start(self, now: datetime) -> bool:
|
||||
"""Would this pack begin a cycle on this tick if the site let it?
|
||||
|
||||
⚠️ THE SAME PREDICATE `tick()` USES, NOT A COPY OF IT. `arbitrate()` has
|
||||
to know who is asking before anybody moves, and a second transcription
|
||||
of "enabled, in the start hour, due and cooled down" is a second opinion
|
||||
about who was asking - so the IDLE branch of `tick()` calls this one.
|
||||
"""
|
||||
return (self.phase == IDLE and self.cfg.enabled
|
||||
and now.hour == self.cfg.start_hour and self.due(now)
|
||||
and self._cooled(now))
|
||||
|
||||
# -- operations ----------------------------------------------------------
|
||||
def force_start(self, now: datetime) -> list:
|
||||
def force_start(self, now: datetime, blocked_by: str = "") -> list:
|
||||
"""Start a cycle regardless of the calendar.
|
||||
|
||||
Commissioning uses this: a cycle must be proven end to end before a site
|
||||
is signed off, and nobody waits a month to find out the schedule never
|
||||
fires.
|
||||
|
||||
⚠️ REGARDLESS OF THE CALENDAR, NOT REGARDLESS OF THE INTERLOCK. The
|
||||
calendar is a preference and an operator may overrule it; "one pack
|
||||
moves power at a time" is a property of the grid connection and an
|
||||
operator pressing a button does not add a second one. A forced start
|
||||
against a busy site is REFUSED, by name, and the phase machine does not
|
||||
move - the refusal is returned as an event so the operator reads it in
|
||||
the action log rather than watching nothing happen.
|
||||
"""
|
||||
if blocked_by:
|
||||
msg = (f"maintenance: forced start REFUSED on {self.name} - "
|
||||
f"{blocked_by}")
|
||||
_LOG.warning("%s", msg)
|
||||
return [msg]
|
||||
events = []
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
@@ -203,23 +365,80 @@ class Maintenance:
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
return events
|
||||
|
||||
def _defer_note(self, why: str, events: list) -> list:
|
||||
"""Say once, not every second, that this pack is waiting its turn.
|
||||
|
||||
⚠️ THE WORDING IS DELIBERATELY NOT AN ABORT AND NOT A TIMEOUT. §12's
|
||||
notes are explicit that a 12 h phase timeout means "the battery is not
|
||||
following commands - a FAULT, not a slow day", and the one thing that
|
||||
must not happen here is an operator reading a deferral as that. This
|
||||
line says the pack is WAITING, names the pack it is waiting for, and
|
||||
says it will run next - none of which any failure path in this module
|
||||
says.
|
||||
"""
|
||||
if self._deferred != why:
|
||||
self._deferred = why
|
||||
msg = (f"maintenance: {self.name} is due and is WAITING its turn - "
|
||||
f"{why}. It is idle under the control loop and will "
|
||||
f"recalibrate at the next start hour once the slot is free; "
|
||||
f"this is not a stalled phase.")
|
||||
_LOG.info("%s", msg)
|
||||
events.append(msg)
|
||||
return events
|
||||
|
||||
# -- the machine ---------------------------------------------------------
|
||||
def tick(self, now: datetime, soc: float | None) -> MaintResult:
|
||||
def tick(self, now: datetime, soc: float | None,
|
||||
blocked_by: str = "") -> MaintResult:
|
||||
"""One cycle of this pack's state machine.
|
||||
|
||||
`blocked_by` is `arbitrate()`'s answer for THIS pack: empty when the
|
||||
site's one maintenance slot is available to it, otherwise the reason it
|
||||
is not. It gates two things and nothing else - a start, and a phase that
|
||||
is already moving power on a pack that does not hold the slot.
|
||||
"""
|
||||
events: list = []
|
||||
phase = self.phase
|
||||
|
||||
# ⚠️ THE SLOT IS CHECKED BEFORE THE PHASE, AND THIS BRANCH IS A RECOVERY
|
||||
# RATHER THAN AN EXPECTED PATH. `arbitrate()` grants the slot to the
|
||||
# pack that is already mid-cycle, so a pack that is BOTH moving power
|
||||
# and blocked means two histories on disk say "drain" - a hand-edited
|
||||
# state file, or a store carried across a version that had no interlock.
|
||||
# The fail-safe direction is unambiguous: two packs pulling against each
|
||||
# other on one connection is the fault SAFETY-31 latches the whole site
|
||||
# for. Stand this one down to 0 W and say why; the holder keeps its
|
||||
# cycle, which is the outcome that loses no coulomb count at all.
|
||||
if blocked_by and phase in POWER_MOVING:
|
||||
events += self.abort(now, f"interlock - {blocked_by}")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
|
||||
if phase == IDLE:
|
||||
if self.cfg.enabled and now.hour == self.cfg.start_hour and self.due(now):
|
||||
last_try = self.store.get_time("last_start_attempt")
|
||||
cooled = (
|
||||
last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN)
|
||||
)
|
||||
if cooled:
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events,
|
||||
"maintenance: due -> drain (exports the surplus)")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if self.wants_start(now):
|
||||
if blocked_by:
|
||||
# ⚠️ `last_start_attempt` IS NOT STAMPED HERE, AND THAT IS
|
||||
# THE STARVATION FIX RATHER THAN AN OMISSION. That key is
|
||||
# the post-ABORT cooldown: it exists so a cycle that failed
|
||||
# does not re-trigger inside the same start hour. A deferral
|
||||
# is not an attempt - nothing was tried and nothing failed -
|
||||
# and stamping it would put this pack under a 90 minute
|
||||
# cooldown for a start hour that is 60 minutes long, so the
|
||||
# pack that lost the arbitration would still be locked out
|
||||
# at the moment the winner released the slot.
|
||||
#
|
||||
# ⚠️ AND THE PHASE DOES NOT MOVE, WHICH IS THE OTHER HALF.
|
||||
# `phase_started` is untouched, so the 12 h DRAIN and 36 h
|
||||
# CHARGE timeouts - which mean "the battery is not following
|
||||
# commands, a fault" - cannot be reached by waiting. A
|
||||
# deferred pack is IDLE under the loop, not a stuck one.
|
||||
return MaintResult(IDLE, False, None, False,
|
||||
self._defer_note(blocked_by, events),
|
||||
blocked_by)
|
||||
self._deferred = ""
|
||||
self.store.set_time("last_start_attempt", now)
|
||||
self._enter(DRAIN, now, events,
|
||||
"maintenance: due -> drain (exports the surplus)")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
self._deferred = ""
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
|
||||
# ⚠️ Fail toward inaction. Without a state-of-charge reading none of the
|
||||
@@ -273,3 +492,77 @@ class Maintenance:
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
|
||||
|
||||
def _days(n: float) -> str:
|
||||
return "never recalibrated" if n == math.inf else f"{n:.0f} d since its last cycle"
|
||||
|
||||
|
||||
def arbitrate(machines, now: datetime) -> list:
|
||||
"""Grant the site's ONE maintenance slot. Returns a list parallel to
|
||||
`machines`: "" for the pack that may move power, otherwise the reason the
|
||||
pack may not.
|
||||
|
||||
⚠️ THE SLOT IS A PROPERTY OF THE GRID CONNECTION, WHICH IS WHY IT IS NOT ON
|
||||
`Maintenance`. Each FSM can see its own pack's schedule and nothing else; the
|
||||
quantity being rationed - "how many phases are moving power across one
|
||||
meter" - is a sum over the roster, exactly like `sum(|B_i|) - |sum(B_i)|` in
|
||||
SAFETY-31 and for the same reason. A per-pack answer to a site-level
|
||||
question is the shape of defect this repository keeps finding.
|
||||
|
||||
⚠️ IT IS DERIVED, NOT PERSISTED, AND THAT IS DELIBERATE. The holder is
|
||||
"whichever pack's stored phase is not IDLE" - a fact already on disk, in the
|
||||
per-pack history the packs themselves write. A separate `maint_slot_holder`
|
||||
key would be a second opinion about the same thing, and the two would
|
||||
disagree the first time the add-on was killed between writing the phase and
|
||||
writing the holder. Restart-safe by construction: a controller that comes
|
||||
back up mid-drain reads the drain and re-derives the holder from it.
|
||||
|
||||
TWO CLAUSES, IN ORDER:
|
||||
|
||||
1. A PACK ALREADY MOVING POWER KEEPS THE SLOT. Nothing preempts a cycle in
|
||||
flight, because a recalibration interrupted halfway is worth less than
|
||||
nothing - the coulomb counter is graded on ONE uninterrupted drain and
|
||||
refill, so a cycle stopped at 40 % has spent the energy and bought no
|
||||
calibration. If more than one pack somehow comes up moving power, the
|
||||
FIRST in roster order holds and `tick()` stands the others down; see the
|
||||
recovery branch there.
|
||||
|
||||
2. OTHERWISE THE LONGEST-WAITING CANDIDATE STARTS. `wants_start()` is asked
|
||||
of every pack, and among those that say yes the slot goes to the one with
|
||||
the largest `waited_days()`. NOT roster order: two packs on one monthly
|
||||
schedule are due in the same hour every month, and a roster-order tie
|
||||
would hand the slot to `inverters[0]` every single time while the second
|
||||
pack's coulomb counter drifted forever - which is, in a different
|
||||
costume, the exact defect this card was opened for. Roster order breaks a
|
||||
genuine numeric tie and nothing else.
|
||||
|
||||
⚠️ AT A ROSTER OF ONE THIS IS THE IDENTITY FUNCTION. One machine is never
|
||||
another machine's blocker: clause 1 finds at most itself and clause 2 has at
|
||||
most one candidate, so it returns `[""]` on every tick and no reason string
|
||||
it can build is ever rendered. That is what makes the one-inverter behaviour
|
||||
byte-identical rather than merely similar.
|
||||
"""
|
||||
blocks = [""] * len(machines)
|
||||
busy = [(i, m) for i, m in enumerate(machines) if m.phase in POWER_MOVING]
|
||||
if busy:
|
||||
held, holder = busy[0]
|
||||
for i, m in enumerate(machines):
|
||||
if i != held:
|
||||
blocks[i] = (f"{holder.name} is mid-cycle ({holder.phase}) and "
|
||||
f"holds the site's one maintenance slot")
|
||||
return blocks
|
||||
|
||||
wants = [(i, m) for i, m in enumerate(machines) if m.wants_start(now)]
|
||||
if len(wants) <= 1:
|
||||
return blocks
|
||||
# Largest waited_days wins; `-index` makes a numeric tie fall to roster
|
||||
# order rather than to whatever `max()` happens to see first.
|
||||
won, winner = max(wants, key=lambda p: (p[1].waited_days(now), -p[0]))
|
||||
for i, m in wants:
|
||||
if i != won:
|
||||
blocks[i] = (f"{winner.name} has waited longer "
|
||||
f"({_days(winner.waited_days(now))} against "
|
||||
f"{_days(m.waited_days(now))}) and takes the site's "
|
||||
f"one maintenance slot first")
|
||||
return blocks
|
||||
|
||||
@@ -43,6 +43,19 @@ SENSORS = [
|
||||
("grid", "goodwe_grid_power", "Grid power", "W", "power", "measurement", None),
|
||||
("battery", "goodwe_battery_power", "Battery power", "W", "power", "measurement", None),
|
||||
("soc", "goodwe_battery_soc", "Battery SoC", "%", "battery", "measurement", None),
|
||||
# SAFETY-31. `sum(|Bi|) - |sum(Bi)|` over MEASURED per-inverter power: the
|
||||
# power going round between the inverters, which the grid sensor above
|
||||
# CANNOT SHOW because it nets to zero there. The two are published side by
|
||||
# side on purpose - "grid 0 W, circulating 6000 W" is the whole phenomenon
|
||||
# in two rows of a dashboard, and no arithmetic on the grid figure alone can
|
||||
# ever produce the second one.
|
||||
#
|
||||
# ⚠️ Published as 0 at the shipped one-inverter roster, not omitted, and
|
||||
# that is a deliberate difference from `p1_age` below. An absent entity is
|
||||
# right for a watchdog input nothing is feeding; this is a quantity whose
|
||||
# value is KNOWN at N=1 - identically zero, for every reading - and a
|
||||
# dashboard row reading 0 W is the honest report of it.
|
||||
("circulation", "goodwe_circulating_power", "Circulating power", "W", "power", "measurement", "mdi:sync-alert"),
|
||||
("phase", "goodwe_maintenance_phase", "Maintenance phase", None, None, None, "mdi:battery-sync"),
|
||||
("status", "goodwe_controller_status", "Controller status", None, None, None, "mdi:heart-pulse"),
|
||||
# ⚠️ THE LIVE ENTITY IS `sensor.goodwe_p1_sample_age`, NOT what this
|
||||
|
||||
@@ -372,7 +372,7 @@ not need re-testing. Nothing here indexes a phase.
|
||||
|
||||
from dataclasses import dataclass
|
||||
|
||||
from .arbiter import P_PEAK, Claim
|
||||
from .arbiter import ACTUATOR_SITE, P_PEAK, Claim
|
||||
from .control import peak_at_risk
|
||||
from .tariff import QUARTER_S
|
||||
|
||||
@@ -744,7 +744,14 @@ def claim(decision: PeakDecision) -> Claim | None:
|
||||
# when the battery stops charging. Spelling them the same way would make the
|
||||
# SAFETY-24 case indistinguishable from the SAFETY-18 one on the one line
|
||||
# that gets read.
|
||||
# ⚠️ ON THE SITE ACTUATOR, EXPLICITLY. The billed quantity is the quarter's
|
||||
# average offtake AT THE GRID CONNECTION - one per site, whatever the site
|
||||
# has behind it - so this floor bounds the site target and is divided by the
|
||||
# allocator along with it. It is never a bound on one unit's share: SAFETY-25
|
||||
# §0c's table has this `lo` at the SITE stage precisely so the deferred loop
|
||||
# reserve's per-inverter `hi` cannot become its counterpart in a `lo > hi`.
|
||||
return Claim.limit(SOURCE, P_PEAK, lo=float(decision.floor_w),
|
||||
reason=("blind" if decision.blind
|
||||
else "SoC floor" if decision.floor_limited
|
||||
else "quarter peak"))
|
||||
else "quarter peak"),
|
||||
actuator=ACTUATOR_SITE)
|
||||
|
||||
@@ -39,6 +39,56 @@ _LOG = logging.getLogger("goodwe.store")
|
||||
# commanding -1000, -2000 W before re-tripping 180 s later. Under a supervisor
|
||||
# that restarts a crashed add-on that is a loop, three minutes of wrong-direction
|
||||
# power at a time, forever.
|
||||
#
|
||||
# ⚠️ AND SINCE DEV-02 THE TWO SAFETY-02 KEYS ARE THE *LEGACY* SPELLING. They are
|
||||
# FLAT - one `sign_tripped` for a controller that now holds a LIST of inverters -
|
||||
# so a trip caused by inverter B would latch inverter A across restarts, and one
|
||||
# operator action would clear both. The LIVE latch is per inverter, under
|
||||
# `unit/<name>/...`, and that is the one the watchdog is restored from.
|
||||
#
|
||||
# ⚠️ THE FLAT PAIR IS NOT DEAD, THOUGH: it is the ROLLBACK VIEW. It is written
|
||||
# alongside the namespaced keys on a trip and cleared alongside them on the
|
||||
# operator's clear, so an add-on that is DOWNGRADED past this schema still finds
|
||||
# the latch it should - and so that a trip taken while the install was rolled
|
||||
# back is still visible to the version that comes back up. Rule 2 of
|
||||
# `migrate_unit_keys()` and `Controller._grade_store_migration()` carry the
|
||||
# argument; the short version is that a latch is only worth persisting if it
|
||||
# survives the version change an operator makes while staring at the banner.
|
||||
#
|
||||
# ⚠️ AND SAFETY-31's PAIR IS FLAT ON PURPOSE, WHICH IS THE OPPOSITE DECISION TO
|
||||
# THE ONE ABOVE AND NEEDS ITS OWN SENTENCE. `circ_tripped` / `circ_reason` are
|
||||
# NOT in `LEGACY_UNIT_KEYS` and must never be moved into a unit namespace.
|
||||
# Circulating power is `sum(|B_i|) - |sum(B_i)|` - a quantity DEFINED over the
|
||||
# whole roster, which is identically zero for any single unit. There is no fact
|
||||
# of the matter about which of two opposing inverters is the offender: a unit
|
||||
# ignoring its share and a sibling faithfully executing a share computed to sum
|
||||
# with it read identically. Namespacing this latch would mean inventing an
|
||||
# attribution the measurement cannot support, and would then let an operator
|
||||
# clear "inverter B's" half of a site-wide loop. One site, one latch.
|
||||
#
|
||||
# It is persisted for SAFETY-34's reason, which this add-on has already paid
|
||||
# for once: `persistent_notification` is IN MEMORY. Home Assistant restarts and
|
||||
# the card is gone while the fault runs on - exactly how the 2026-09-02 outage
|
||||
# went unseen for 6 h 25 m with the detector correct throughout. main.py
|
||||
# re-raises the notification from this key on every start.
|
||||
#
|
||||
# ⚠️ AND SAFETY-30's PAIR IS FLAT FOR THE SAME REASON SAFETY-31's IS, WHICH IS
|
||||
# NOT THE SAME REASON THE ONES ABOVE ARE NAMESPACED. `site_sign_tripped` /
|
||||
# `site_sign_reason` hold the SITE sign-disagreement latch: the SUM of every
|
||||
# standing command opposed the meter, continuously. That is a statement about
|
||||
# the grid connection - the offending number is the site target, which no single
|
||||
# inverter owns - so there is no unit to hang it on, and hanging it on one would
|
||||
# let an operator clear "inverter B's half" of a fault that has no halves.
|
||||
# `unit/<name>/sign_tripped` above stays what it always was and now means what
|
||||
# it says: THAT unit's own command against THAT unit's own measured power.
|
||||
#
|
||||
# ⚠️ AND THEY ARE NOT IN `LEGACY_UNIT_KEYS`, MUST NEVER BE, AND ARE NOT WRITTEN
|
||||
# AT A ROSTER OF ONE AT ALL. At N=1 the site comparison and the unit comparison
|
||||
# are the same sentence and `Controller.cycle()` arms only the per-unit
|
||||
# detector, so a one-inverter install's state file is byte-identical to what it
|
||||
# was before this card - these two keys sit at their defaults and nothing reads
|
||||
# them. A rollback therefore finds exactly the flat `sign_tripped` mirror it
|
||||
# always found.
|
||||
DEFAULTS = {
|
||||
"phase": "idle",
|
||||
"phase_started": None,
|
||||
@@ -46,8 +96,449 @@ DEFAULTS = {
|
||||
"last_start_attempt": None,
|
||||
"sign_tripped": False,
|
||||
"sign_reason": "",
|
||||
"circ_tripped": False,
|
||||
"circ_reason": "",
|
||||
"site_sign_tripped": False,
|
||||
"site_sign_reason": "",
|
||||
}
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# DEV-02: PER-INVERTER KEYS, AND THE MIGRATION IS THE RISKY HALF
|
||||
#
|
||||
# ⚠️ A LATCH THAT SILENTLY FAILS TO MIGRATE IS A DISARMED SAFETY GUARD ON AN
|
||||
# INSTALL THAT BELIEVES IT IS PROTECTED. SAFETY-02's whole reason for being
|
||||
# persisted is that "restart the add-on" is the FIRST thing an operator staring
|
||||
# at a FAILSAFE banner tries, and a latch held only in memory comes back armed,
|
||||
# into the fault, unattended. A latch that is written down under a key nothing
|
||||
# reads any more is exactly the same failure with a longer paper trail: the file
|
||||
# still says `sign_tripped: true`, the banner is green, and the controller
|
||||
# resumes driving the wrong way.
|
||||
#
|
||||
# So this is a MIGRATION WITH A POSTCONDITION, not a copy. `migrate_unit_keys()`
|
||||
# reports what it did AND reads the result back; `Controller.__init__` grades
|
||||
# that report and refuses to come up quietly if the latch did not survive. The
|
||||
# test that grades it BREAKS the migration and watches the guard fire.
|
||||
# --------------------------------------------------------------------------- #
|
||||
|
||||
# 0 = the flat, one-inverter layout that shipped before DEV-02.
|
||||
# 1 = per-inverter keys under `unit/<name>/...`.
|
||||
SCHEMA_VERSION = 1
|
||||
SCHEMA_KEY = "schema_version"
|
||||
|
||||
# Which flat keys belong to ONE inverter, and therefore move into its namespace.
|
||||
# ⚠️ THE MAINTENANCE KEYS ARE STILL NOT IN HERE, AND SINCE MAINT-05 THAT IS A
|
||||
# DIFFERENT DECISION RATHER THAN THE SAME ONE. They DO move now - one
|
||||
# `Maintenance` per roster entry needs one history per roster entry - but they
|
||||
# move on their OWN marker, `MAINT_SCHEMA_KEY`, and only on a site that actually
|
||||
# has more than one pack. Two conditions the SAFETY-02 keys do not share, so
|
||||
# folding them into this tuple would either drag them across on a
|
||||
# single-inverter install (which is the byte-identical store layout MAINT-05
|
||||
# must not change) or hold the sign latch hostage to a roster count it has
|
||||
# nothing to do with. `MAINT_UNIT_KEYS` below carries them.
|
||||
LEGACY_UNIT_KEYS = ("sign_tripped", "sign_reason")
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# MAINT-05: THE SECOND MIGRATION, AND WHY IT IS A SECOND ONE
|
||||
#
|
||||
# 0 = the flat, one-history layout every install has had since the add-on
|
||||
# shipped: `phase` / `phase_started` / `last_completed` /
|
||||
# `last_start_attempt` describe THE pack, because there was one FSM.
|
||||
# 1 = one history per roster entry, under `unit/<name>/...`.
|
||||
#
|
||||
# ⚠️ ITS OWN MARKER, NOT A BUMP OF `SCHEMA_VERSION`, AND THE REASON IS THAT THE
|
||||
# TWO MIGRATIONS DO NOT HAVE THE SAME PRECONDITION. DEV-02's runs on every
|
||||
# install exactly once and is monotone in the version number. This one runs ONLY
|
||||
# WHERE THE ROSTER HAS MORE THAN ONE PACK, because at N=1 §6.2's identity holds
|
||||
# and the flat keys ARE that pack's namespace - moving them would add four keys
|
||||
# and a version marker to a store MAINT-05's own acceptance criterion requires
|
||||
# to be byte-identical. A single monotone counter cannot express "migrated on
|
||||
# this site, deliberately not migrated on that one" without lying to the next
|
||||
# version that reads it: a one-inverter store would have to be left at the old
|
||||
# number forever, and then a genuine v2 migration could never be told apart from
|
||||
# a site that simply never grew.
|
||||
#
|
||||
# ⚠️ AND IT IS TWO MARKERS, NOT TWO COPIES OF THE THREE RULES.
|
||||
# `_move_flat_keys()` and `_verify_moves()` below are shared verbatim by both
|
||||
# migrations, so rules 1 and 3 and the READ-BACK POSTCONDITION are one
|
||||
# implementation. A second transcription of a migration is a second opinion
|
||||
# about what "it landed" means.
|
||||
MAINT_SCHEMA_VERSION = 1
|
||||
MAINT_SCHEMA_KEY = "maint_schema_version"
|
||||
|
||||
# The flat maintenance-history keys, in the order they are moved.
|
||||
# ⚠️ THE VALUES ARE THE FLAT SPELLINGS AND THE MODULE THAT READS THEM INDEXES
|
||||
# THIS SAME TUPLE (`maintenance.UnitHistory`), so a key renamed here cannot
|
||||
# silently stop being migrated - the same property `UNIT_STORE_KEYS` gives the
|
||||
# SAFETY-02 pair.
|
||||
MAINT_UNIT_KEYS = ("phase", "phase_started", "last_completed",
|
||||
"last_start_attempt")
|
||||
|
||||
|
||||
def unit_key(unit: str, key: str) -> str:
|
||||
"""The namespaced Store key for `key` on inverter `unit`.
|
||||
|
||||
⚠️ ONE SPELLING, IN ONE PLACE. `Inverter.key()` calls this and so does the
|
||||
migration, so a check can assert that what was migrated is what is read.
|
||||
Two transcriptions of a key name is one copy plus a future disagreement
|
||||
about which one holds the latch - and the copy that drifts is always the one
|
||||
that reads.
|
||||
"""
|
||||
return f"unit/{unit}/{key}"
|
||||
|
||||
|
||||
class MigrationReport:
|
||||
"""What `migrate_unit_keys()` did, and whether it can be believed.
|
||||
|
||||
⚠️ IT CARRIES `verified`, WHICH IS READ BACK FROM THE STORE RATHER THAN
|
||||
ASSUMED FROM THE ASSIGNMENT. That is the difference between this and a
|
||||
two-line copy: the caller is able to ask "is the latch that was in the file
|
||||
before now under the key the watchdog reads", and a `False` there is a
|
||||
disarmed guard, which is an ERROR and not a log line nobody sees.
|
||||
"""
|
||||
|
||||
def __init__(self):
|
||||
self.ran = False # did anything need moving
|
||||
self.from_version = 0
|
||||
self.moved = {} # new key -> value written
|
||||
self.kept = [] # keys already namespaced, left alone
|
||||
self.verified = True # every move read back equal
|
||||
self.problems = [] # human-readable, one per failed move
|
||||
# ⚠️ THE SUBSET THAT MATTERS, AND THE DISTINCTION IS NOT PEDANTRY. A
|
||||
# store that drops a write of `sign_tripped=False` has lost the
|
||||
# DEFAULT - the same statement "absent" already makes, so nothing is
|
||||
# gone. One that drops a write of `True` has lost A LATCH. Only the
|
||||
# second is a disarmed safety guard, and only the second may be allowed
|
||||
# to shout: an alarm that fires on the harmless case is an alarm an
|
||||
# operator learns to dismiss before the real one arrives.
|
||||
self.lost = []
|
||||
# ⚠️ A DIFFERENT FAILURE FROM `lost`, AND IT HAS TO BE, BECAUSE THE
|
||||
# READ-BACK CANNOT SEE IT. `lost` is "the store took the write and
|
||||
# dropped it". This is "the store took the write, kept it perfectly, and
|
||||
# NOTHING WILL EVER READ IT" - the migration was handed a unit name that
|
||||
# is not on the roster, so every machine looks under a different key and
|
||||
# finds nothing. There is no harmless-default version of this the way
|
||||
# there is for `lost`: a write nobody reads is not information, whatever
|
||||
# its value, so anything in here fails `ok` on its own.
|
||||
self.misdirected = []
|
||||
# Why nothing ran, when nothing ran. Empty means "already at schema".
|
||||
self.skipped = ""
|
||||
|
||||
@property
|
||||
def ok(self) -> bool:
|
||||
"""Nothing that CARRIED STATE failed to land, and it landed WHERE THE
|
||||
MACHINES LOOK."""
|
||||
return not self.lost and not self.misdirected
|
||||
|
||||
def explain(self) -> str:
|
||||
if not self.ran:
|
||||
# ⚠️ `skipped` RATHER THAN A SECOND SENTENCE ABOUT VERSIONS. Since
|
||||
# MAINT-05 there are two reasons a migration does not run - the
|
||||
# store is already at this schema, or the roster has one pack and
|
||||
# the flat keys ARE its namespace - and an operator reading the
|
||||
# startup log needs to be told which, because only one of them
|
||||
# changes when a second inverter is declared.
|
||||
return self.skipped or (f"store already at schema "
|
||||
f"{self.from_version}; no "
|
||||
f"per-inverter migration needed")
|
||||
out = (f"migrated {len(self.moved)} flat key(s) to inverter "
|
||||
f"namespaces: " + ", ".join(sorted(self.moved)))
|
||||
if self.kept:
|
||||
out += " (left alone, already namespaced: " + ", ".join(sorted(self.kept)) + ")"
|
||||
if self.problems:
|
||||
out += " - PROBLEMS: " + "; ".join(self.problems)
|
||||
if self.lost:
|
||||
out += " - STATE LOST: " + "; ".join(self.lost)
|
||||
if self.misdirected:
|
||||
out += " - WRONG NAMESPACE: " + "; ".join(self.misdirected)
|
||||
return out
|
||||
|
||||
|
||||
def migrate_unit_keys(store, unit: str) -> MigrationReport:
|
||||
"""Move the pre-DEV-02 flat per-inverter keys into `unit`'s namespace.
|
||||
|
||||
`unit` is the FIRST inverter in the roster, which on every install that can
|
||||
possibly have a flat key is the only one it ever had. A store written by a
|
||||
version that knew about more than one inverter is already at
|
||||
SCHEMA_VERSION and is not touched.
|
||||
|
||||
THE THREE RULES, each one a case that would otherwise be a wrong answer:
|
||||
|
||||
1. IT NEVER OVERWRITES AN EXISTING NAMESPACED VALUE. A store that has both
|
||||
spellings has been written by this version, and the namespaced one is
|
||||
where the WATCHDOG is restored from. Preferring the flat one HERE would
|
||||
resurrect a trip the operator has already cleared, because a migration
|
||||
runs before anything can tell the two apart. Deciding between them is
|
||||
main.py's job and it has the one rule that can: the flat key carries new
|
||||
information only when NOTHING namespaced is latched.
|
||||
2. THE FLAT KEYS ARE LEFT IN THE FILE, AND THEY ARE KEPT LIVE. Deleting
|
||||
them buys tidiness and costs a rollback: an operator who downgrades the
|
||||
add-on after a migration would find no latch at all, which is the
|
||||
disarmed guard again in the other direction. Left in place, a downgrade
|
||||
finds the trip it had.
|
||||
|
||||
⚠️ AND "LEFT IN PLACE" IS NOT ENOUGH ON ITS OWN, WHICH IS WHAT THIS RULE
|
||||
USED TO SAY. The sentence here read "they go stale from this moment -
|
||||
nothing writes them again - and the direction that staleness fails in is
|
||||
a SPURIOUS latch, never a missing one". That was true of the latch this
|
||||
migration MOVES and false of every trip that happens AFTERWARDS: nothing
|
||||
flat was written for those, so a rollback found `sign_tripped: false` and
|
||||
came up DRIVING. So main.py mirrors both keys on a trip and clears both
|
||||
on the operator's clear. The flat pair is the ROLLBACK VIEW of the latch,
|
||||
maintained, not a fossil - which is also what lets main.py's
|
||||
`_grade_store_migration()` run on every start and catch a trip that
|
||||
happened while the install was rolled back (see its docstring: the flat
|
||||
key saying tripped while no inverter came up tripped is the one
|
||||
disagreement that can occur, and it is a DOWNGRADE-WINDOW LATCH).
|
||||
3. THE VERSION MARKER IS WRITTEN LAST. A crash between the copies and the
|
||||
marker leaves the migration to run again, and rule 1 makes running it
|
||||
again a no-op. A marker written first would leave a half-migrated store
|
||||
looking finished.
|
||||
"""
|
||||
rep = MigrationReport()
|
||||
data = getattr(store, "data", {})
|
||||
rep.from_version = int(data.get(SCHEMA_KEY, 0) or 0)
|
||||
if rep.from_version >= SCHEMA_VERSION:
|
||||
return rep
|
||||
|
||||
rep.ran = True
|
||||
_move_flat_keys(store, unit, LEGACY_UNIT_KEYS, rep)
|
||||
_verify_moves(store, rep)
|
||||
|
||||
if rep.ok:
|
||||
store.set(SCHEMA_KEY, SCHEMA_VERSION)
|
||||
else:
|
||||
# ⚠️ NOT MARKED DONE. A migration that lost state must run again on the
|
||||
# next start rather than be recorded as finished - the one thing worse
|
||||
# than a failed migration is a failed migration a later version skips.
|
||||
_LOG.error("per-inverter store migration LOST STATE and has not been "
|
||||
"marked done: %s", rep.explain())
|
||||
return rep
|
||||
|
||||
|
||||
def _move_flat_keys(store, unit: str, keys, rep: MigrationReport) -> None:
|
||||
"""Rule 1, once, for both migrations.
|
||||
|
||||
Copies each flat `key` to `unit/<unit>/<key>` UNLESS the namespaced spelling
|
||||
is already present - a store that has both has been written by a version
|
||||
that knew about the namespace, and that value is the live one. Rule 2 is the
|
||||
absence of a delete: the flat keys are left exactly where they were.
|
||||
"""
|
||||
data = getattr(store, "data", {})
|
||||
for legacy in keys:
|
||||
target = unit_key(unit, legacy)
|
||||
if target in data:
|
||||
rep.kept.append(target)
|
||||
continue
|
||||
# ⚠️ `DEFAULTS[legacy]` RATHER THAN A LITERAL. An install that never
|
||||
# tripped has no `sign_tripped` in its file at all, and the value it
|
||||
# then lands on has to be the one `Store.load()` would have supplied -
|
||||
# otherwise "absent" and "never tripped" stop being the same statement,
|
||||
# which is the distinction store.py's own header is about. The same
|
||||
# sentence holds for `last_completed`: absent means "never recalibrated"
|
||||
# and a literal here would be a second opinion about that.
|
||||
value = data.get(legacy, DEFAULTS.get(legacy))
|
||||
store.set(target, value)
|
||||
rep.moved[target] = value
|
||||
|
||||
|
||||
def _verify_moves(store, rep: MigrationReport, roster=None) -> None:
|
||||
"""THE POSTCONDITION, AND IT IS A READ-BACK RATHER THAN AN ASSUMPTION.
|
||||
|
||||
This is the difference between these functions and a two-line copy: the
|
||||
caller can ask "is the latch that was in the file before now under the key
|
||||
the watchdog reads" - and, since MAINT-05, "is the history that was in the
|
||||
file before now under the key THIS PACK's state machine reads" - through the
|
||||
same `unit_key()` those readers read through. A `False` here is a guard that
|
||||
is off, or a month of coulomb-count history gone, on an install whose state
|
||||
file says otherwise.
|
||||
|
||||
⚠️ AND `roster` IS THE OTHER HALF, WHICH THE READ-BACK ON ITS OWN CANNOT BE.
|
||||
A POSTCONDITION THAT READS BACK THE NAMESPACE IT WAS HANDED CANNOT DETECT
|
||||
BEING HANDED THE WRONG ONE. That is not a hypothetical: MAINT-05 shipped
|
||||
with `migrate_maint_keys()` taking a bare `unit` string, and a call site that
|
||||
passed `inverter.UNIT_A` instead of the first roster entry's name migrated an
|
||||
install's whole maintenance history into `unit/inverter-a/...` on a roster of
|
||||
`["garage", "shed"]`, read all four keys back under that same name, was
|
||||
SATISFIED, and stamped the schema marker - so the next start skipped the
|
||||
migration too and both packs came up believing they had never been
|
||||
recalibrated. Every symptom of a clean migration, and the history gone.
|
||||
`build_roster()` names a declared roster's entries from the config and falls
|
||||
back to a POSITIONAL `inverter-N`, so `inverter-a` is not even the default
|
||||
there; there is no roster on which that write could have been read.
|
||||
|
||||
So the namespace is graded against the one the MACHINES read - the roster -
|
||||
rather than against the argument this function was handed, which is the
|
||||
thing under test. A unit that is not on the roster is `misdirected`, which
|
||||
fails `ok`, which means the caller does NOT stamp the version marker and the
|
||||
next start runs the migration again. A re-run is recoverable, by rule 1; a
|
||||
silent skip is the state store.py's header says must never happen.
|
||||
|
||||
⚠️ AND THE GRADED SET IS `moved` UNION `kept`, WHICH IS WHAT MAKES THAT
|
||||
PARAGRAPH TRUE ON THE SECOND START AS WELL AS THE FIRST. Graded over `moved`
|
||||
alone the refusal lasted exactly one start: the wrong call site is still
|
||||
wrong next time, finds the keys it wrote already present, and rule 1 routes
|
||||
every one of them to `kept` - so `moved` is empty, this loop sees nothing,
|
||||
`ok` comes back True and the marker is stamped on a migration that has
|
||||
reached no readable key. The measurement is in the comment on the loop
|
||||
itself. `test_maintenance.py` section 9c calls this twice with the SAME
|
||||
wrong `unit` over one store, which is the shape nothing in the suite had.
|
||||
|
||||
`roster=None` means "not graded", and the one caller that passes it is
|
||||
`migrate_unit_keys()`, which runs BEFORE `build_roster()` for the reason its
|
||||
own docstring gives - the `Inverter` objects restore their latch in their
|
||||
constructors, so the keys have to be in place before there is a roster to
|
||||
check against. That gap is real and is recorded as a running check rather
|
||||
than left to a comment: see test_maintenance.py section 13.
|
||||
"""
|
||||
for target, value in rep.moved.items():
|
||||
got = getattr(store, "data", {}).get(target, "<<missing>>")
|
||||
if got == value:
|
||||
continue
|
||||
rep.verified = False
|
||||
note = f"{target} was written as {value!r} and reads back as {got!r}"
|
||||
rep.problems.append(note)
|
||||
legacy = target.rsplit("/", 1)[-1]
|
||||
if value != DEFAULTS.get(legacy):
|
||||
rep.lost.append(note)
|
||||
|
||||
if roster is None:
|
||||
return
|
||||
names = [str(n) for n in roster]
|
||||
# `unit_key()` builds `unit/<unit>/<key>`, so the unit is field 1. Split
|
||||
# through the same spelling the writer used rather than re-deriving it.
|
||||
#
|
||||
# ⚠️ `moved` UNION `kept`, AND THE UNION IS THE WHOLE OF THE SECOND FIX
|
||||
# ROUND. Grading only `moved` made the refusal last EXACTLY ONE START.
|
||||
# Measured at Controller level over one persisted store, roster
|
||||
# ["garage", "shed"], flat `last_completed` 2026-08-07, with the call site
|
||||
# still handing `inverter-a` on both starts:
|
||||
#
|
||||
# construction 1: ok=False misdirected=4 moved=4 kept=0 marker=<absent>
|
||||
# construction 2: ok=True misdirected=0 moved=0 kept=4 marker=1
|
||||
#
|
||||
# On start 2 the four keys the WRONG start 1 wrote are already present, so
|
||||
# rule 1 routes every one of them to `rep.kept`, `rep.moved` is EMPTY, this
|
||||
# loop iterates over nothing, `misdirected` is empty and `ok` is True - so
|
||||
# the caller stamps the marker and start 3 takes the `from_version >=
|
||||
# SCHEMA` early return FOREVER, including after the call site is fixed.
|
||||
# Loud-and-recoverable became silent-and-permanent after one restart: the
|
||||
# exact state this module's header says must never happen, reached by the
|
||||
# fix that was written to prevent it.
|
||||
#
|
||||
# The union is sound by construction rather than by hope: every entry in
|
||||
# both `rep.moved` and `rep.kept` is a `unit_key(unit, legacy)` built from
|
||||
# the SAME `unit` argument, so grading `kept` grades the same namespace
|
||||
# decision `moved` does. A correct call site puts its `kept` entries under a
|
||||
# roster name and they pass; a wrong one cannot launder its namespace by
|
||||
# having already written it.
|
||||
for target in sorted(set(rep.moved) | set(rep.kept)):
|
||||
parts = target.split("/")
|
||||
unit = parts[1] if len(parts) > 2 else ""
|
||||
if unit in names:
|
||||
continue
|
||||
rep.verified = False
|
||||
note = (f"{target} was migrated into namespace {unit!r}, which is NOT "
|
||||
f"on the roster {names!r} - nothing reads that key")
|
||||
rep.problems.append(note)
|
||||
rep.misdirected.append(note)
|
||||
|
||||
|
||||
def migrate_maint_keys(store, unit: str, roster) -> MigrationReport:
|
||||
"""Move the flat maintenance history into the FIRST pack's namespace.
|
||||
|
||||
MAINT-05. Until this card there was one `Maintenance` and one history, and
|
||||
`store.py`'s own header argued the keys should stay flat because per-pack
|
||||
scheduling was a card of its own. This is that card: there is now one FSM
|
||||
per roster entry, so there is one history per roster entry, and the flat one
|
||||
belongs to the pack that was being recalibrated - `inverters[0]`, which is
|
||||
what `Controller.maint_unit` named and what `validate.py` rule 6 graded
|
||||
against.
|
||||
|
||||
⚠️ `len(roster) <= 1` IS A RETURN, NOT A SPECIAL CASE. At one inverter the
|
||||
flat keys ARE that pack's namespace (§6.2's identity, the same one
|
||||
`arbiter.actuator_for()` leans on), `Maintenance` is constructed to read
|
||||
them directly, and a migration would add four keys plus a marker to a store
|
||||
that must come out byte-identical. The migration happens on the day the
|
||||
roster grows, which is the day the flat spelling stops being able to answer
|
||||
"which pack".
|
||||
|
||||
⚠️ `roster` IS REQUIRED, AND IT REPLACED AN `n_units: int`. Two reasons, and
|
||||
the second is the one MAINT-05 was rejected over.
|
||||
|
||||
The small one: `n_units` was `len(self.inverters)` at the only call site, so
|
||||
the roster carries it - `len(roster)` - and a count passed beside the names
|
||||
is a second opinion about how many packs there are.
|
||||
|
||||
The load-bearing one: THE NAMES ARE THE POSTCONDITION. `unit` says which
|
||||
pack the flat keys belonged to and that is genuinely a decision - the first
|
||||
roster entry, because that is the pack the one FSM was driving - but a
|
||||
decision the caller can get WRONG, and until this signature existed nothing
|
||||
could tell. `_verify_moves()` read back the namespace it was handed, so a
|
||||
migration into a name no machine reads verified clean and stamped the
|
||||
marker. Handing the roster in means the read-back is graded against the
|
||||
keys the MACHINES read, and a `unit` that is not among these names comes
|
||||
back `misdirected`: not `ok`, marker NOT written, migration runs again next
|
||||
start - and again the start after that, because `_verify_moves()` grades
|
||||
`kept` as well as `moved`. See `_verify_moves()` for the install this was
|
||||
measured on, and for what grading `moved` alone cost on start 2.
|
||||
|
||||
THE THREE RULES ARE `migrate_unit_keys()`'s, SHARED IN CODE rather than
|
||||
restated: `_move_flat_keys()` is rule 1 (never overwrite a namespaced value)
|
||||
and rule 2 (the flat keys are left in the file), `_verify_moves()` is the
|
||||
read-back postcondition, and the marker is written LAST so a crash before it
|
||||
leaves the migration to run again - which rule 1 makes a no-op.
|
||||
|
||||
⚠️ AND RULE 2 IS KEPT LIVE HERE TOO, WHICH IS THE HALF DEV-02 HAD TO ADD
|
||||
LATER. "Left in place" alone makes the flat history a fossil dated the day
|
||||
the second inverter was declared: an operator who rolls back to a
|
||||
single-FSM add-on would find a `last_completed` months old and recalibrate a
|
||||
pack that does not need it, or - worse - a stale `phase` and a
|
||||
`phase_started` old enough to abort on the 12 h timeout the moment it comes
|
||||
up. So `maintenance.UnitHistory` MIRRORS the first pack's writes back onto
|
||||
the flat keys for as long as the roster has more than one entry. The flat
|
||||
pair is the ROLLBACK VIEW of the history, maintained, exactly as
|
||||
`sign_tripped` is the rollback view of the latch.
|
||||
"""
|
||||
rep = MigrationReport()
|
||||
data = getattr(store, "data", {})
|
||||
names = [str(n) for n in roster]
|
||||
rep.from_version = int(data.get(MAINT_SCHEMA_KEY, 0) or 0)
|
||||
if len(names) <= 1:
|
||||
rep.skipped = ("one inverter: the flat maintenance keys ARE that pack's "
|
||||
"history and are read in place, so there is nothing to "
|
||||
"move and the store layout does not change")
|
||||
return rep
|
||||
if rep.from_version >= MAINT_SCHEMA_VERSION:
|
||||
rep.skipped = (f"maintenance history already at schema "
|
||||
f"{rep.from_version}; written by a multi-inverter "
|
||||
f"version and not touched")
|
||||
return rep
|
||||
|
||||
rep.ran = True
|
||||
_move_flat_keys(store, unit, MAINT_UNIT_KEYS, rep)
|
||||
_verify_moves(store, rep, roster=names)
|
||||
|
||||
# ⚠️ `rep.ok` AND NOTHING ELSE - NOT `ok or kept`, NOT `not lost`, NOT
|
||||
# `not misdirected`. BOTH guards gate this line and each one is pinned by a
|
||||
# check that the other cannot satisfy: section 9c refuses a store whose
|
||||
# failure is `misdirected` with `lost` empty, and section 9d refuses one
|
||||
# whose failure is `lost` with `misdirected` empty AND `kept` non-empty -
|
||||
# the mutation `if rep.ok or rep.kept:` stamps the marker on a migration
|
||||
# that lost a month of history, and until section 9d existed all 19 suites
|
||||
# were green on it.
|
||||
if rep.ok:
|
||||
store.set(MAINT_SCHEMA_KEY, MAINT_SCHEMA_VERSION)
|
||||
else:
|
||||
# ⚠️ NOT MARKED DONE, FOR EITHER FAILURE. The same sentence
|
||||
# `migrate_unit_keys()` carries: the one thing worse than a failed
|
||||
# migration is a failed migration a later version skips. Rule 1 makes
|
||||
# the re-run a no-op where the keys did land, so refusing the marker
|
||||
# costs one repeated pass and buys the difference between a migration
|
||||
# that can still be fixed and one the store says already happened.
|
||||
_LOG.error("per-pack maintenance-history migration did NOT land and "
|
||||
"has not been marked done: %s", rep.explain())
|
||||
return rep
|
||||
|
||||
|
||||
class Store:
|
||||
def __init__(self, path: str = "/data/state.json"):
|
||||
|
||||
@@ -74,7 +74,8 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
was overruled. That firmware file's own comment says a lower bound on this
|
||||
"belongs in CFG-01, not here" - so here it is.
|
||||
|
||||
5. `sign_disagree_w` at or above `max_w`. [(a)]
|
||||
5. `sign_disagree_w` - or SAFETY-30's `unit_sign_disagree_w` - at or above
|
||||
`max_w`. [(a)]
|
||||
The arbiter's `supervised` limit bounds every command to +-max_w, and
|
||||
SAFETY-02's predicate needs `abs(command) > sign_disagree_w`. Set the
|
||||
threshold at or above the ceiling and the command side of the comparison
|
||||
@@ -150,6 +151,32 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
permits equality because equality there leaves one reachable point that
|
||||
works; here it leaves none.
|
||||
|
||||
9. An `inverters:` roster that cannot mean what it says. [(a) and (b)]
|
||||
CFG-04's five cases are enumerated on `_roster_problems()`. Three of them
|
||||
are (b) - an entry with no `setpoint_entity`, or no rating, is a unit that
|
||||
takes a share of the site target every cycle and delivers none of it, on a
|
||||
status page that reports a site running at full strength. Two are (a): two
|
||||
entries sharing a name share one Store namespace, so one unit's SAFETY-02
|
||||
latch IS the other's and an operator clearing one clears both; and a flat
|
||||
`setpoint_entity` left set beside a declared roster is an actuator the
|
||||
configuration names and nothing writes.
|
||||
|
||||
⚠️ RULES 5 AND 6 CHANGED SHAPE FOR THIS, and that is the part worth
|
||||
reading. Both compared a threshold against the flat `max_w`, which was
|
||||
right while there was exactly one inverter and is a PERMISSIVE READER the
|
||||
moment there are two: `max_w: 5000` left over from a single-inverter
|
||||
install, beside a roster of two 2000 W units, passed rule 5 at
|
||||
`sign_disagree_w: 3000` while the watchdog could fire on NEITHER unit -
|
||||
rule 5's own failure mode, reached through rule 5. They now read
|
||||
`unit_caps()`, which is the roster's caps and, at one inverter, is
|
||||
`[max_w]` exactly.
|
||||
|
||||
What rule 9 deliberately does NOT do is grade a rating against a device.
|
||||
`dev_min`/`dev_max` here are one device's range and there are now N of
|
||||
them, none of which has answered at startup. `validate_unit_ranges()` is
|
||||
the per-unit form and main.py runs it from `run_control()`, once every
|
||||
unit's own ESPHome has replied.
|
||||
|
||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
|
||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||
@@ -202,11 +229,13 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
import logging
|
||||
|
||||
from .arbitrage import enabled as arbitrage_on
|
||||
from .inverter import roster_entries
|
||||
from .maintenance import MAINT_OPTION_DEFAULTS
|
||||
from .p1 import is_enabled, validate_meter_options
|
||||
from .peakguard import PEAK_OPTION_DEFAULTS
|
||||
from .price import PRICE_OPTION_DEFAULTS, PROVIDERS
|
||||
from .static_tariff import ProfileInvalid, parse_static_profile
|
||||
from .watchdog import SIGN_OPTION_DEFAULTS
|
||||
|
||||
_LOG = logging.getLogger("goodwe.config")
|
||||
|
||||
@@ -229,17 +258,307 @@ _LOG = logging.getLogger("goodwe.config")
|
||||
# a matching integer means a matching rule.
|
||||
FIRMWARE_INGEST_VETO_S = 30.0
|
||||
|
||||
# ⚠️ The complete set of option keys through which this add-on can reach an
|
||||
# actuator. specs §1.5 makes "any configuration in which two writers can reach
|
||||
# one actuator" a non-goal, and the way that non-goal is ENFORCED here is by
|
||||
# construction: there is exactly one such key, so a second writer is not
|
||||
# expressible in the options schema at all. sim/inject.py's `two_writers`
|
||||
# scenario asserts on this tuple - if a second write path is ever added, that
|
||||
# scenario goes red and somebody has to decide how the two are arbitrated
|
||||
# BEFORE the config that allows both can ship.
|
||||
# ⚠️ THE OPTION KEYS UNDER WHICH A WRITER CAN BE DECLARED - AN ENUMERATION, AND
|
||||
# SAFETY-28 DEMOTED IT TO ONE. This tuple used to BE the guarantee. The comment
|
||||
# that stood here said specs §1.5 makes "any configuration in which two writers
|
||||
# can reach one actuator" a non-goal, and that the non-goal was ENFORCED by
|
||||
# construction: exactly one such key, so a second writer is not expressible in
|
||||
# the options schema at all.
|
||||
#
|
||||
# That was true, and it graded THE SHAPE OF THE OPTIONS SCHEMA rather than the
|
||||
# writes. Add CFG-04's per-inverter config - a list of inverters, each with its
|
||||
# own `setpoint_entity` - and there are two real writers with `len()` of this
|
||||
# tuple still equal to 1. The check stays green while the property it protects
|
||||
# is gone, which is this repository's named failure mode: a check that observes
|
||||
# something other than what it claims to observe.
|
||||
#
|
||||
# So the guarantee moved to `actuator_writers()` below, which counts WRITERS PER
|
||||
# ACTUATOR rather than keys, and finds them wherever in the options tree they
|
||||
# are declared. This tuple survives only because a census has to know which key
|
||||
# NAMES an actuator; it is not a bound on how many writers there can be, and
|
||||
# nothing should ever assert on its length again.
|
||||
ACTUATOR_WRITE_KEYS = ("setpoint_entity",)
|
||||
|
||||
|
||||
def _collect_writers(node, path: str, out: list) -> None:
|
||||
"""Walk the options tree, collecting `(where, entity)` for every writer.
|
||||
|
||||
⚠️ STRUCTURAL, NOT NAME-BASED ON THE CONTAINER, and that is the point. A
|
||||
census that looked for a key called `inverters` would be guessing the name
|
||||
CFG-04 has not chosen yet, and a guess that is wrong goes GREEN while two
|
||||
writers exist - the same defect one level along. This walks whatever shape
|
||||
the options happen to have and reports every `setpoint_entity` in it,
|
||||
however deeply nested and under whatever container.
|
||||
"""
|
||||
if isinstance(node, dict):
|
||||
for k, v in node.items():
|
||||
here = f"{path}.{k}" if path else str(k)
|
||||
if k in ACTUATOR_WRITE_KEYS:
|
||||
entity = str(v or "").strip()
|
||||
if entity:
|
||||
out.append((here, entity))
|
||||
continue
|
||||
_collect_writers(v, here, out)
|
||||
elif isinstance(node, (list, tuple)):
|
||||
for i, v in enumerate(node):
|
||||
_collect_writers(v, f"{path}[{i}]", out)
|
||||
|
||||
|
||||
def actuator_writers(opts: dict) -> dict:
|
||||
"""actuator -> the configured writers that can reach it. INSTANCE-AWARE.
|
||||
|
||||
The replacement for `len(ACTUATOR_WRITE_KEYS) == 1`. It answers HOW MANY
|
||||
THINGS CAN WRITE TO EACH ACTUATOR, which is the property §1.5 actually
|
||||
names, and it keeps answering it when the schema grows a per-inverter list:
|
||||
two inverters with two entities are two writers on two actuators and fine,
|
||||
two declarations naming ONE entity are the non-goal and are refused.
|
||||
|
||||
The key is the entity id, lowercased - Home Assistant entity ids are
|
||||
lowercase by construction, and folding case here means a config cannot
|
||||
smuggle a second writer past the census on `Number.X` versus `number.x`.
|
||||
|
||||
⚠️ SAY WHAT THIS STILL DOES NOT OBSERVE, because the argument that demoted
|
||||
the tuple applies to its replacement too. This is a census of CONFIGURED
|
||||
writers. A second write path added in CODE - a `hass.set_number()` call next
|
||||
to some new strategy - declares nothing and is invisible here, exactly as it
|
||||
was invisible to the tuple. That hole is not closed at startup and cannot
|
||||
be: it is closed at runtime, by `Controller.write_refusal()`, which refuses
|
||||
any value the single allocator did not place on this tick and does not care
|
||||
what the options look like. The two checks are deliberately different
|
||||
kinds - one grades the config, one grades the writes - and only the second
|
||||
one survives a schema this file has not seen yet.
|
||||
"""
|
||||
found: list = []
|
||||
_collect_writers(opts, "", found)
|
||||
census: dict = {}
|
||||
for where, entity in found:
|
||||
census.setdefault(entity.lower(), []).append(where)
|
||||
return census
|
||||
|
||||
|
||||
def unit_caps(opts: dict) -> list[float]:
|
||||
"""Each configured inverter's supervised cap, in roster order.
|
||||
|
||||
⚠️ WHY THIS EXISTS AT ALL, AND IT IS THE PERMISSIVE-READER PROBLEM IN THIS
|
||||
FILE. Rules 5 and 6 both compare a threshold against "max_w", and both of
|
||||
them are really comparing it against WHAT ONE UNIT MAY BE COMMANDED - the
|
||||
arbiter files `supervised` per inverter, from `inv.max_w`, and there is no
|
||||
such thing as a site rating on the wire. At one inverter those are the same
|
||||
number and reading the flat option was right. At two they are not: a config
|
||||
with `max_w: 5000` left over from a single-inverter install and a roster of
|
||||
two 2000 W units would pass rule 5 at `sign_disagree_w: 3000` while the
|
||||
watchdog could not fire on EITHER unit - the disarmed-guard-reporting-armed
|
||||
state those rules exist to refuse, reached through the rule itself.
|
||||
|
||||
So the caps come from the roster the add-on will actually build
|
||||
(`inverter.roster_entries()`, not a second reading of the option), and fall
|
||||
back to the flat `max_w` only where that roster is the flat one too.
|
||||
"""
|
||||
return [cap for _, cap in unit_caps_indexed(opts)]
|
||||
|
||||
|
||||
def unit_caps_indexed(opts: dict) -> list[tuple[int, float]]:
|
||||
"""`unit_caps()`, but each cap carries the ROSTER INDEX it came from.
|
||||
|
||||
⚠️ WHY THE INDEX HAS TO TRAVEL WITH THE NUMBER. This function SKIPS entries
|
||||
with no usable `max_w`, so position i in the caps list is not position i in
|
||||
the roster the moment one entry is malformed. Rules 5 and 6 used to feed a
|
||||
caps-list index straight into `_unit_label()`, which indexes `entries` - so
|
||||
on a roster whose first entry has a junk `max_w`, the refusal named the
|
||||
WRONG INVERTER. An operator told to lower a number on `inverter-a` when the
|
||||
number is on `inverter-b` is being sent to the wrong device by the very
|
||||
message that exists to stop that. Rule 9(d) already refuses such a config so
|
||||
the two lists cannot desynchronise in shipped use - but "unreachable" is a
|
||||
claim about today's rule ordering, not a property of this function, and
|
||||
`validate_startup_config()` is also `sim/inject.py`'s entry point.
|
||||
"""
|
||||
entries = roster_entries(opts)
|
||||
if not entries:
|
||||
cap = _number(opts, "max_w", 2000.0)
|
||||
return [] if cap is None else [(0, cap)]
|
||||
caps: list[tuple[int, float]] = []
|
||||
for index, entry in enumerate(entries):
|
||||
if not isinstance(entry, dict):
|
||||
continue
|
||||
cap = _number(entry, "max_w", None)
|
||||
if cap is not None:
|
||||
caps.append((index, cap))
|
||||
return caps
|
||||
|
||||
|
||||
def _unit_label(opts: dict, index: int) -> str:
|
||||
""""" at a single-inverter config, " (inverter-b)" at a roster.
|
||||
|
||||
The messages below have to read identically on the install that upgrades
|
||||
into this version - it is the same configuration, refused for the same
|
||||
reason - and have to NAME THE UNIT the moment there is more than one, or an
|
||||
operator with three inverters is told a number is wrong and not which one.
|
||||
"""
|
||||
entries = roster_entries(opts)
|
||||
if len(entries) <= 1:
|
||||
return ""
|
||||
entry = entries[index] if index < len(entries) else {}
|
||||
name = ""
|
||||
if isinstance(entry, dict):
|
||||
name = str(entry.get("name") or "").strip()
|
||||
return f" ({name or f'inverters[{index}]'})"
|
||||
|
||||
|
||||
def _roster_problems(opts: dict) -> list[str]:
|
||||
"""Rule 9 (CFG-04): the `inverters:` roster, refused where it cannot mean
|
||||
what it says.
|
||||
|
||||
⚠️ THE SUPERVISOR ALREADY ENFORCES MOST OF THIS AND THAT IS NOT A REASON TO
|
||||
DROP IT. `config.yaml`'s schema makes `name`, `setpoint_entity` and `max_w`
|
||||
required per entry, and Supervisor 2026.08.0 refuses a blob that omits one
|
||||
by name - measured, not assumed. But `validate_startup_config()` is also
|
||||
`sim/inject.py`'s entry point and every check's, and those reach it with a
|
||||
dict the Supervisor never saw; the same argument `price_provider` makes two
|
||||
rules up. A rule the Supervisor duplicates costs nothing and covers the
|
||||
callers it does not.
|
||||
|
||||
Five things are refused, and each is a config that would otherwise RUN:
|
||||
|
||||
a. `inverters` is not a list. `roster_entries()` wraps a scalar so this
|
||||
can name it; without the rule the roster would be one inverter built
|
||||
out of a string's `.get`, i.e. an immediate AttributeError.
|
||||
b. An entry with no usable `name`. Store keys are namespaced BY NAME
|
||||
(`store.unit_key`), so two nameless entries would share one namespace
|
||||
and one unit's SAFETY-02 latch would silently be the other's.
|
||||
c. Two entries with the SAME name - (b) reached the long way round.
|
||||
d. An entry with no `setpoint_entity`, or no usable `max_w`. The first is
|
||||
a unit this controller cannot command; the second is a unit whose
|
||||
supervised claim would be `+-0 W`, which is a unit pinned at zero by a
|
||||
missing key rather than by a decision.
|
||||
e. A flat `setpoint_entity` alongside a declared roster. The flat keys are
|
||||
the SINGLE-inverter shape; leaving one set while a roster is declared
|
||||
means one of two things and neither is safe. If it names an entity an
|
||||
entry also names, SAFETY-28's census below already refuses it as two
|
||||
writers on one actuator. If it names a DIFFERENT one, nothing writes
|
||||
it, the site runs quietly smaller than the configuration reads, and the
|
||||
one place it would show up is a status page nobody compares against the
|
||||
config. Refused rather than ignored, for §1.5's reason and for this
|
||||
card's: a config that silently becomes a different config is worse than
|
||||
one that refuses to load.
|
||||
"""
|
||||
problems: list[str] = []
|
||||
raw = opts.get("inverters")
|
||||
if raw is None or raw == "" or raw == []:
|
||||
return problems
|
||||
if not isinstance(raw, (list, tuple)):
|
||||
return [f"inverters is {type(raw).__name__} {raw!r}, and it must be a "
|
||||
"LIST of inverter objects - one per inverter, each naming its "
|
||||
"own name, setpoint_entity and max_w. A single inverter needs "
|
||||
"no list at all: leave `inverters` empty and the flat "
|
||||
"setpoint_entity/soc_entity/batt_entity/max_w keys describe it."]
|
||||
|
||||
entries = roster_entries(opts)
|
||||
seen: dict = {}
|
||||
for i, entry in enumerate(entries):
|
||||
where = f"inverters[{i}]"
|
||||
if not isinstance(entry, dict):
|
||||
problems.append(
|
||||
f"{where} is {type(entry).__name__} {entry!r}, and every entry "
|
||||
"must be an object with at least name, setpoint_entity and "
|
||||
"max_w.")
|
||||
continue
|
||||
name = str(entry.get("name") or "").strip()
|
||||
if not name:
|
||||
problems.append(
|
||||
f"{where} has no name. Every inverter needs one: the Store "
|
||||
"namespaces this unit's SAFETY-02 latch, its heartbeat and its "
|
||||
"write bookkeeping under it, so two unnamed units would share "
|
||||
"one namespace and a trip caused by one would latch the other. "
|
||||
"Any short identifier works - inverter-a, inverter-b, garage.")
|
||||
elif name in seen:
|
||||
problems.append(
|
||||
f"{where} and {seen[name]} are both called {name!r}. The Store "
|
||||
"keys every per-unit latch under the unit's name, so two units "
|
||||
"with one name share one SAFETY-02 latch and one heartbeat "
|
||||
"deadline - a trip caused by either would stop both, and an "
|
||||
"operator clearing it would clear both. Give them different "
|
||||
"names.")
|
||||
else:
|
||||
seen[name] = where
|
||||
who = f"{where} ({name})" if name else where
|
||||
if not str(entry.get("setpoint_entity") or "").strip():
|
||||
problems.append(
|
||||
f"{who} has no setpoint_entity, so this add-on cannot command "
|
||||
"it. It would sit in the roster, take a share of the site "
|
||||
"target every cycle and deliver none of it, while the status "
|
||||
"page showed a site running at full strength. Give it the "
|
||||
"ESPHome number entity that carries ITS setpoint, or remove "
|
||||
"the entry.")
|
||||
if _number(entry, "max_w", None) is None or (_number(entry, "max_w", None) or 0) <= 0:
|
||||
problems.append(
|
||||
f"{who} has no usable max_w (got {entry.get('max_w')!r}). It is "
|
||||
"the supervised cap on what may be written to THIS inverter, it "
|
||||
"is not shared with any other unit and it is deliberately not "
|
||||
"inherited from the flat max_w - a rating borrowed from a "
|
||||
"sibling is exactly what DEV-02 removed. State this unit's own "
|
||||
"rating in watts.")
|
||||
|
||||
flat_sp = str(opts.get("setpoint_entity") or "").strip()
|
||||
if entries and flat_sp:
|
||||
problems.append(
|
||||
f"setpoint_entity is set to {flat_sp} AND an inverters list of "
|
||||
f"{len(entries)} is declared. The flat setpoint_entity/soc_entity/"
|
||||
"batt_entity/max_w keys are the SINGLE-inverter shape and are not "
|
||||
"read at all once a roster exists, so this config declares an "
|
||||
"actuator that nothing will ever write - a site running quietly "
|
||||
"smaller than its own configuration. Move that inverter into the "
|
||||
"list as its own entry and clear setpoint_entity.")
|
||||
return problems
|
||||
|
||||
|
||||
def validate_unit_ranges(units, *, skip_entity: str = "") -> list[str]:
|
||||
"""Rule 2, per inverter, against each unit's OWN reported device range.
|
||||
|
||||
⚠️ THE READER THIS REPLACES FAILED PERMISSIVE, WHICH IS THE DIRECTION THAT
|
||||
HIDES A DEFECT. `run_control()` re-ran rule 2 behind `if
|
||||
self.o.get("setpoint_entity")` - the FLAT key - because the flat options
|
||||
were the only per-device options there were. Declare a roster and that key
|
||||
is blank by rule 9(e), so the whole re-check was skipped and NO inverter's
|
||||
`max_w` was ever graded against the device it is written to. That is rule
|
||||
2's own failure mode restored by a config shape: the operator's stated
|
||||
ceiling is not the ceiling and nothing says which won.
|
||||
|
||||
`units` is the roster (anything with `.name`, `.setpoint_entity`, `.max_w`,
|
||||
`.dev_min`, `.dev_max`). A unit whose device did not answer is SKIPPED, not
|
||||
guessed at, for the reason in this module's docstring: ESPHome is often not
|
||||
up when the add-on boots and (None, None) means "not read", not "zero".
|
||||
|
||||
`skip_entity` is the flat `setpoint_entity` when the caller has already
|
||||
graded it through `validate_startup_config(opts, dev_min, dev_max)`. At a
|
||||
single-inverter config that is the one unit, and grading it twice would
|
||||
report the same conflict twice under two wordings.
|
||||
"""
|
||||
problems: list[str] = []
|
||||
skip = str(skip_entity or "").strip().lower()
|
||||
for unit in units:
|
||||
entity = str(getattr(unit, "setpoint_entity", "") or "").strip()
|
||||
if not entity or entity.lower() == skip:
|
||||
continue
|
||||
cap = float(getattr(unit, "max_w", 0.0) or 0.0)
|
||||
dev_min = getattr(unit, "dev_min", None)
|
||||
dev_max = getattr(unit, "dev_max", None)
|
||||
name = getattr(unit, "name", entity)
|
||||
if dev_max is not None and cap > float(dev_max):
|
||||
problems.append(
|
||||
f"{name}: max_w is {cap:.0f} W but {entity} accepts at most "
|
||||
f"{float(dev_max):.0f} W - THE DEVICE WINS, so the {cap:.0f} W "
|
||||
f"configured for this inverter would silently never happen. "
|
||||
f"Lower this entry's max_w to {float(dev_max):.0f} W or less.")
|
||||
elif dev_min is not None and -cap < float(dev_min):
|
||||
problems.append(
|
||||
f"{name}: max_w is {cap:.0f} W, so this controller may command "
|
||||
f"{-cap:.0f} W, but {entity} accepts no less than "
|
||||
f"{float(dev_min):.0f} W - THE DEVICE WINS on the charge side. "
|
||||
f"Lower this entry's max_w to {abs(float(dev_min)):.0f} W or "
|
||||
"less.")
|
||||
return problems
|
||||
|
||||
|
||||
class ConfigRefused(Exception):
|
||||
"""The configuration is wrong. Not "something broke" - see main.py's handler.
|
||||
|
||||
@@ -265,9 +584,8 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
"""
|
||||
problems: list[str] = []
|
||||
|
||||
# --- 1. an actuator to write to ------------------------------------------
|
||||
writers = [k for k in ACTUATOR_WRITE_KEYS
|
||||
if str(opts.get(k, "") or "").strip()]
|
||||
# --- 1. an actuator to write to, and AT MOST ONE WRITER PER ACTUATOR -----
|
||||
writers = actuator_writers(opts)
|
||||
if not writers:
|
||||
problems.append(
|
||||
"setpoint_entity is not set, so this add-on has no actuator: every "
|
||||
@@ -275,8 +593,45 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
"ESP32 heartbeat that holds off the layer-1 failsafe never happens. "
|
||||
"It would run, look healthy, and move no energy at all. Set it to "
|
||||
"the ESPHome number entity that carries the setpoint.")
|
||||
# SAFETY-28. The §1.5 non-goal, graded on the writers rather than on the
|
||||
# count of option keys. Read `actuator_writers()` for why the old check went
|
||||
# green on the very config this one is here to refuse.
|
||||
#
|
||||
# ⚠️ AND IT REFUSES A DUPLICATE DECLARATION EVEN WHEN BOTH NAME THE SAME
|
||||
# ENTITY, which is the case an author of the per-inverter config will meet
|
||||
# first: keep `setpoint_entity` as inverter A's and add A to the list again
|
||||
# and there are two config sites aimed at one actuator, each with its own
|
||||
# neighbouring options. "They happen to be the same entity, so it is fine"
|
||||
# is precisely the reasoning that makes two writers invisible. Declare each
|
||||
# actuator exactly once and the refusal does not fire.
|
||||
for actuator, who in sorted(writers.items()):
|
||||
if len(who) > 1:
|
||||
problems.append(
|
||||
f"{len(who)} configured writers can reach the one actuator "
|
||||
f"{actuator}: {', '.join(who)}. specs §1.5 makes any "
|
||||
"configuration in which two writers can reach one actuator a "
|
||||
"non-goal - two independent setpoints on one inverter is the "
|
||||
"arbitration problem this add-on refuses to have, and at "
|
||||
"runtime it is a meter-emulation target being written twice a "
|
||||
"second by two strategies that cannot see each other. Give "
|
||||
"each actuator exactly one writer, or point the second one at "
|
||||
"its own entity.")
|
||||
|
||||
# --- 9. CFG-04's roster, graded BEFORE anything reads a per-unit number --
|
||||
# ⚠️ FIRST, THOUGH IT IS THE NEWEST RULE. Rules 5 and 6 below now ask the
|
||||
# roster what one unit may be commanded, so a roster that is nonsense has to
|
||||
# have been named as nonsense before they read it - otherwise an entry with
|
||||
# no `max_w` silently contributes no cap, `min()` sees a shorter list, and
|
||||
# the operator is told about a sign watchdog when the real problem is a
|
||||
# missing rating one line up.
|
||||
problems.extend(_roster_problems(opts))
|
||||
|
||||
# --- 2. the configured ceiling against the device's own rating -----------
|
||||
# ⚠️ THE FLAT `max_w`, AND ONLY THE FLAT ONE. `dev_min`/`dev_max` are ONE
|
||||
# device's range - the flat `setpoint_entity`'s - so this rule can only ever
|
||||
# speak for the single-inverter shape. The per-unit form of it is
|
||||
# `validate_unit_ranges()`, which main.py runs once every unit's own device
|
||||
# has answered; it is not called from here because at startup no device has.
|
||||
max_w = _number(opts, "max_w", 2000.0)
|
||||
if max_w is None:
|
||||
problems.append(f"max_w {opts.get('max_w')!r} is not a number")
|
||||
@@ -355,20 +710,71 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
# below max_w, so threshold == max_w is already unsatisfiable. Anything
|
||||
# BELOW max_w is reachable and therefore fine - this refuses the disarmed
|
||||
# case only, not "close to the rail".
|
||||
#
|
||||
# ⚠️ AND IT IS GRADED AGAINST THE SMALLEST UNIT'S CAP, NOT AGAINST THE FLAT
|
||||
# `max_w`. There is one SignWatchdog PER INVERTER (DEV-02) and each grades
|
||||
# its own unit's standing command, which the arbiter bounds by THAT UNIT's
|
||||
# `supervised` claim - so the watchdog that can never fire is the one on the
|
||||
# smallest inverter, and a threshold under the site's largest cap says
|
||||
# nothing about it. At one inverter `unit_caps()` is `[max_w]` and this is
|
||||
# the identical comparison it always was.
|
||||
sign_w = _number(opts, "sign_disagree_w", 300.0)
|
||||
# ⚠️ (index, cap) PAIRS, NOT BARE CAPS. `unit_caps()` skips entries with no
|
||||
# usable `max_w`, so `caps.index(weakest)` was an index into the CAPS list
|
||||
# being handed to `_unit_label()`, which indexes the ROSTER - and the message
|
||||
# named the wrong inverter as soon as the two lengths differed. The index
|
||||
# travels with the number now, so the name is the name of the unit the
|
||||
# number came off.
|
||||
caps_ix = unit_caps_indexed(opts)
|
||||
caps = [cap for _, cap in caps_ix]
|
||||
weakest = min(caps) if caps else None
|
||||
if sign_w is None:
|
||||
problems.append(f"sign_disagree_w {opts.get('sign_disagree_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and sign_w >= max_w:
|
||||
elif weakest is not None and weakest > 0 and sign_w >= weakest:
|
||||
where = _unit_label(opts, min(caps_ix, key=lambda p: p[1])[0])
|
||||
problems.append(
|
||||
f"sign_disagree_w is {sign_w:.0f} W but max_w is {max_w:.0f} W, so "
|
||||
f"sign_disagree_w is {sign_w:.0f} W but max_w{where} is "
|
||||
f"{weakest:.0f} W, so "
|
||||
"the SAFETY-02 sign-disagreement watchdog can never fire: the "
|
||||
"arbiter never lets a command exceed max_w, and the watchdog needs "
|
||||
f"a command over {sign_w:.0f} W. It would sit there reporting "
|
||||
"'armed' on the status page while being incapable of tripping - the "
|
||||
f"one runaway failure mode this system has actually observed. Lower "
|
||||
f"sign_disagree_w below {max_w:.0f} W (300 W is the measured "
|
||||
f"sign_disagree_w below {weakest:.0f} W (300 W is the measured "
|
||||
"default), or raise max_w.")
|
||||
|
||||
# ⚠️ AND THE SAME RULE FOR SAFETY-30's PER-UNIT THRESHOLD, WHICH IS A
|
||||
# SEPARATE COMPARISON AND THEREFORE A SEPARATE WAY TO DISARM. It grades a
|
||||
# unit's own SHARE against that unit's own measured power, and a share is
|
||||
# bounded by the same `supervised` claim at +-max_w - so a threshold at or
|
||||
# above the ceiling makes the command side unsatisfiable by construction,
|
||||
# exactly as above. Written as its own branch rather than folded into the
|
||||
# one above because the two produce different sentences and an operator
|
||||
# needs to be told WHICH watchdog they have disarmed.
|
||||
#
|
||||
# ⚠️ REFUSED EVEN AT A ROSTER OF ONE, WHERE THIS CHECK IS NOT ARMED. A
|
||||
# config that cannot work is refused when it is WRITTEN, not on the day a
|
||||
# second inverter is added - which is the day nobody is watching the startup
|
||||
# log. This is `meter_max_age_s`'s rule read the same way: the failure it
|
||||
# prevents is silent.
|
||||
unit_sign_w = _number(opts, "unit_sign_disagree_w",
|
||||
float(SIGN_OPTION_DEFAULTS["unit_sign_disagree_w"]))
|
||||
if unit_sign_w is None:
|
||||
problems.append(f"unit_sign_disagree_w "
|
||||
f"{opts.get('unit_sign_disagree_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and unit_sign_w >= max_w:
|
||||
problems.append(
|
||||
f"unit_sign_disagree_w is {unit_sign_w:.0f} W but max_w is "
|
||||
f"{max_w:.0f} W, so the SAFETY-30 per-inverter sign-disagreement "
|
||||
"watchdog can never fire: no inverter is ever commanded past max_w, "
|
||||
f"and the watchdog needs a command over {unit_sign_w:.0f} W. At two "
|
||||
"inverters that is the guard which catches a unit doing the "
|
||||
"OPPOSITE of what it was told while its sibling covers for it at "
|
||||
"the meter - the case the site-level watchdog is structurally "
|
||||
f"blind to. Lower unit_sign_disagree_w below {max_w:.0f} W "
|
||||
f"({SIGN_OPTION_DEFAULTS['unit_sign_disagree_w']:.0f} W is the "
|
||||
"measured default), or raise max_w.")
|
||||
|
||||
# --- 6. a maintenance charge the ceiling can actually accommodate --------
|
||||
# ⚠️ Strictly `>`, matching the arbiter exactly. The shaping is
|
||||
# `Claim.limit(hi=-charge_w)` against `supervised`'s `lo=-max_w`, so
|
||||
@@ -395,22 +801,63 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
# the one in-code mirror of config.yaml for this family - the same move
|
||||
# rule 8 below already makes with `PEAK_OPTION_DEFAULTS` - and
|
||||
# test_maintenance.py pins it by reading the shipped file.
|
||||
#
|
||||
# ⚠️ MAINT-05: IT IS GRADED AGAINST THE WEAKEST UNIT'S CAP NOW, AND THE
|
||||
# COMMENT THIS REPLACES SAID SO WOULD HAPPEN. It read: "there is exactly ONE
|
||||
# `Maintenance` in this add-on and `Controller.maint_unit` names the pack it
|
||||
# recalibrates - the first in the roster, because the cycle's history lives
|
||||
# under un-namespaced Store keys. The shaping claim is filed on THAT
|
||||
# actuator and on no other, so the cap that can contradict it is THAT
|
||||
# unit's. Taking `min()` here would refuse a perfectly workable site - a
|
||||
# 5000 W pack being recalibrated beside a 2000 W sibling the cycle never
|
||||
# touches ... When `maint_unit` stops being `inverters[0]`, this line moves
|
||||
# with it."
|
||||
#
|
||||
# `maint_unit` has stopped being `inverters[0]`. There is one `Maintenance`
|
||||
# per roster entry, each with its own namespaced history, and EVERY pack is
|
||||
# recalibrated on its own schedule - so the sibling "the cycle never
|
||||
# touches" does not exist any more and the over-refusal argument has no
|
||||
# subject. The shaping claim is filed on whichever pack is charging, so the
|
||||
# cap that can contradict it is any cap on the roster, and the one that
|
||||
# contradicts it FIRST is the smallest. This is rule 5's conjunction for
|
||||
# rule 5's reason: a threshold that is fine against the biggest unit says
|
||||
# nothing about the smallest, and the smallest is the one that goes to 0 W.
|
||||
#
|
||||
# ⚠️ THIS REFUSES CONFIGS THAT USED TO START, AND THAT IS THE POINT RATHER
|
||||
# THAN A SIDE EFFECT. `max_w` 5000 on pack A beside 2000 on pack B with
|
||||
# `maintenance_charge_w` 3000 was accepted before this card and was correct
|
||||
# while only pack A was ever recalibrated. Pack B now recalibrates too, and
|
||||
# its cheap-window charge asks the arbiter for `hi = -3000` against a
|
||||
# supervised `lo = -2000`: `lo > hi`, arbiter clause 3, 0 W, contradiction -
|
||||
# a maintenance charge that silently never happens on that pack, which is
|
||||
# exactly what rule 6 exists to refuse at the moment it is WRITTEN. At a
|
||||
# roster of one `min()` over one cap is that cap and the comparison, the
|
||||
# message and the boundary are identical.
|
||||
charge_w = _number(opts, "maintenance_charge_w",
|
||||
float(MAINT_OPTION_DEFAULTS["maintenance_charge_w"]))
|
||||
# ⚠️ THE SAME PAIRING AS RULE 5, FOR THE SAME REASON: `unit_caps_indexed()`
|
||||
# SKIPS entries with no usable `max_w`, so a caps-list position is not a
|
||||
# roster position and `_unit_label()` indexes the roster. The index travels
|
||||
# with the number, so the unit the message names is the unit the number came
|
||||
# off - which on a roster whose first entry has a junk `max_w` is not the
|
||||
# same thing at all.
|
||||
maint_index, maint_cap = (min(caps_ix, key=lambda p: p[1]) if caps_ix
|
||||
else (0, None))
|
||||
maint_where = _unit_label(opts, maint_index)
|
||||
if charge_w is None:
|
||||
problems.append(
|
||||
f"maintenance_charge_w {opts.get('maintenance_charge_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and charge_w > max_w:
|
||||
elif maint_cap is not None and maint_cap > 0 and charge_w > maint_cap:
|
||||
problems.append(
|
||||
f"maintenance_charge_w is {charge_w:.0f} W but max_w is "
|
||||
f"{max_w:.0f} W, so a maintenance charge in a cheap window can "
|
||||
f"maintenance_charge_w is {charge_w:.0f} W but max_w{maint_where} is "
|
||||
f"{maint_cap:.0f} W, so a maintenance charge in a cheap window can "
|
||||
"never happen: the shaping asks the arbiter for at most "
|
||||
f"{-charge_w:.0f} W while the supervised limit allows no less than "
|
||||
f"{-max_w:.0f} W, which is a contradiction it resolves to 0 W - "
|
||||
f"{-maint_cap:.0f} W, which is a contradiction it resolves to 0 W - "
|
||||
"THE CEILING WINS, and what you would see is an ARBITER "
|
||||
"CONTRADICTION line that reads like a bug rather than like these "
|
||||
f"two numbers. Lower maintenance_charge_w to {max_w:.0f} W or less, "
|
||||
f"or raise max_w to at least {charge_w:.0f} W.")
|
||||
f"two numbers. Lower maintenance_charge_w to {maint_cap:.0f} W or "
|
||||
f"less, or raise max_w to at least {charge_w:.0f} W.")
|
||||
|
||||
# --- 7. two price sources on one site ------------------------------------
|
||||
problems.extend(_price_problems(opts))
|
||||
@@ -470,18 +917,23 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
# three-way divergence (config.yaml 2000, MaintConfig 2500) and the card
|
||||
# named only the charge side. Closing one key and leaving its twin is how a
|
||||
# single-source fix gets reproduced as a single-source bug one line down.
|
||||
# ⚠️ AND AGAINST THE MAINTENANCE UNIT'S CAP, for rule 6's reason: it is the
|
||||
# same one actuator being clamped, so grading the warning against the flat
|
||||
# `max_w` would warn about a site number while the clamp is a unit number.
|
||||
disch_w = _number(opts, "maintenance_discharge_w",
|
||||
float(MAINT_OPTION_DEFAULTS["maintenance_discharge_w"]))
|
||||
if disch_w is not None and max_w is not None and max_w > 0 and disch_w > max_w:
|
||||
if (disch_w is not None and maint_cap is not None and maint_cap > 0
|
||||
and disch_w > maint_cap):
|
||||
_LOG.warning(
|
||||
"maintenance_discharge_w %.0f W is above max_w %.0f W. Not refused - "
|
||||
"the drain phase SETS the setpoint and the arbiter clamps it to "
|
||||
"%.0f W and names the clamp ('limited by supervised(max_w)'), so "
|
||||
"nothing is silent and the cycle still completes. But it drains at "
|
||||
"%.0f W, not the %.0f W you configured, and the drain phase has a "
|
||||
"720 min timeout. Lower it to %.0f W or raise max_w to remove the "
|
||||
"maintenance_discharge_w %.0f W is above max_w%s %.0f W. Not "
|
||||
"refused - the drain phase SETS the setpoint and the arbiter clamps "
|
||||
"it to %.0f W and names the clamp ('limited by supervised(max_w)'), "
|
||||
"so nothing is silent and the cycle still completes. But it drains "
|
||||
"at %.0f W, not the %.0f W you configured, and the drain phase has "
|
||||
"a 720 min timeout. Lower it to %.0f W or raise max_w to remove the "
|
||||
"surprise.",
|
||||
disch_w, max_w, max_w, max_w, disch_w, max_w)
|
||||
disch_w, maint_where, maint_cap, maint_cap, maint_cap, disch_w,
|
||||
maint_cap)
|
||||
|
||||
return problems
|
||||
|
||||
|
||||
@@ -164,11 +164,106 @@ saturation freeze's question (|command - the battery's actual power| > 500 W,
|
||||
NOTES.md §4.7 row 4), and the two checks are complementary rather than
|
||||
overlapping. Neither substitutes for the other.
|
||||
|
||||
⚠️ THAT PARAGRAPH IS ABOUT THE COMMAND-VERSUS-METER COMPARISON, AND SINCE
|
||||
SAFETY-30 THAT IS NOT THE ONLY ONE THIS MODULE DRIVES. At a roster of two or
|
||||
more each unit is ALSO graded against its own measured power, which is exactly
|
||||
the comparison the paragraph says nothing here makes - see the SAFETY-30 section
|
||||
below, which says what that does and does not take away from the freeze. At the
|
||||
shipped roster of one the paragraph stands unchanged, word for word: the site
|
||||
comparison is the only detector armed and the freeze is still the whole answer.
|
||||
|
||||
Nor does it see a sign inversion introduced DOWNSTREAM of this add-on - in the
|
||||
firmware, on the wire, or in a future driver. Our view stays self-consistent and
|
||||
this stays silent. That is a wire-versus-intent problem and it belongs to the
|
||||
witness, which is the only vantage point that sees both.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
SAFETY-30 - AT TWO INVERTERS THIS IS TWO QUESTIONS, NOT ONE
|
||||
|
||||
Everything above was written at a roster of ONE, and at N=1 it is right for a
|
||||
reason that stops being true at N=2. `commanded_w` is what THIS controller put
|
||||
on THIS actuator. `grid_w` is what the WHOLE SITE is exchanging with the
|
||||
network. At one inverter those are two views of one thing - §6.2's identity -
|
||||
which is what makes comparing them sound. At two they are not:
|
||||
|
||||
* A FALSE TRIP THE COMPARISON CANNOT AVOID. "Inverter A commanded -1500 W
|
||||
while the meter reads +1500 W" is evidence of nothing at N=2: inverter B may
|
||||
be discharging 3000 W and doing exactly what it was told. No fault anywhere,
|
||||
and the check NOTES.md calls the highest-value entry in the safety table -
|
||||
93 % agreement while healthy against 4 % during runaway, four episodes, zero
|
||||
false positives - fires.
|
||||
* THE CONVERSE, WHICH IS WORSE. A unit genuinely driving the wrong way is
|
||||
MASKED, because the site figure NETS. Commanded +1500 W, measured -1500 W,
|
||||
beside a sibling measured at +1500 W: the meter sits exactly where a healthy
|
||||
site leaves it. This is not a threshold that is set too high - the
|
||||
information is destroyed by the summation, and no tuning recovers it.
|
||||
|
||||
So the one comparison becomes two, each asked of the evidence that can answer
|
||||
it, and they are DIFFERENT FAULTS rather than one fault at two scales:
|
||||
|
||||
PER UNIT this unit's standing command against ITS OWN measured power -
|
||||
`Inverter.batt`, which on the live system is holding register
|
||||
0x0518, this inverter's own AC power, per-instance since DEV-02.
|
||||
Conclusion: "THE ACTUATOR I AM DRIVING IS NOT DOING WHAT I TOLD
|
||||
IT". The evidence is about one unit, so the remedy is that unit:
|
||||
the `failsafe` SET, which arbiter.CLAIM_SCOPE has called a UNIT
|
||||
claim from the day it was written, for this exact reason.
|
||||
SITE the SUM of the standing commands against the meter. Conclusion:
|
||||
"THE SITE AS A WHOLE IS DRIVING THE WRONG WAY" - an inverted gain,
|
||||
an integrator wound past the rail, a strategy pushing the wrong
|
||||
side of the meter. That is the fault the 2026-08-20 capture
|
||||
contains and it is a property of the CONNECTION, so the remedy is
|
||||
the connection: a SITE SET that stops every inverter.
|
||||
|
||||
⚠️ AND AT N=1 THERE IS EXACTLY ONE ARMED DETECTOR, WHICH IS THE ONE THAT
|
||||
SHIPPED. The two questions above are the SAME SENTENCE at a roster of one: the
|
||||
sum of one command is that command, and "the site" and "the unit" name one
|
||||
actuator. Arming both would be arming a duplicate - two latches, two banners and
|
||||
two chances to spend a false-positive record that was earned by ONE comparison
|
||||
on two captured bus days. `Controller.cycle()` therefore hands the single unit's
|
||||
watchdog THE METER, under the shipped `sign_disagree_w` / `sign_disagree_s`,
|
||||
exactly as before, and never arms the site one. `arm()` below is where that
|
||||
choice is written down. Nothing about a one-inverter install changes - not the
|
||||
comparison, not the thresholds, not the store keys, not the claim, not the
|
||||
banner.
|
||||
|
||||
⚠️ WHAT THE PER-UNIT COMPARISON IS NOT. Two guards that overlap without saying
|
||||
so is how a false-alarm generator gets built, so both neighbours are named:
|
||||
|
||||
* IT IS NOT SAFETY-31. `circulation.py` compares the units AGAINST EACH OTHER
|
||||
- `sum(|B_i|) - |sum(B_i)|` over MEASURED power - and catches two inverters
|
||||
pushing THROUGH each other, which nets to zero at the meter and about which
|
||||
no single command is evidence at all. This compares each unit against ITS
|
||||
OWN COMMAND. Take two units faithfully executing an allocation that ALLOC-01
|
||||
would refuse: circulating power is the whole loop, and every per-unit sign
|
||||
check here reads perfect agreement. Take one unit doing the exact opposite
|
||||
of its share while its sibling covers for it: this reads the whole
|
||||
disagreement, and circulating power can be zero, because the two measured
|
||||
powers may well agree in sign. Neither is the other with a different
|
||||
threshold.
|
||||
* IT IS NOT THE SATURATION FREEZE, AND THE OVERLAP IS REAL AND BOUNDED. The
|
||||
freeze asks `|command - measured| > saturation_w` (500 W) and concludes "the
|
||||
inverter cannot follow"; it then stops the integrator winding, which is a
|
||||
control action taken every day, on a unit that is merely SATURATED as
|
||||
readily as on one that is reversed, and it neither latches nor parks
|
||||
anything. This asks for OPPOSITION - a sign, on both sides of a threshold,
|
||||
held continuously - which a saturated-but-obedient unit cannot produce at
|
||||
all, and it LATCHES and commands that unit to zero. The freeze is a
|
||||
magnitude test that shapes the loop; this is a direction test that stops an
|
||||
actuator.
|
||||
|
||||
⚠️ GATE 1 STILL APPLIES TO BOTH, AND THAT IS A DELIBERATE CHOICE WITH A COST.
|
||||
The per-unit comparison could have been armed whenever ANY non-zero command is
|
||||
standing - a unit should do what it is told whoever told it - and that would
|
||||
catch a wedged inverter during a maintenance charge. It is not, because the
|
||||
whole no-false-positive argument above is built on `following`, because the
|
||||
freeze already grades that window, and because this card's own warning is that
|
||||
SAFETY-02's record was earned at N=1 and must not be spent on a check that fires
|
||||
when nothing is wrong. What it costs is written here rather than discovered:
|
||||
between the start of a maintenance cycle and its end, a unit reversing against
|
||||
its own command is the freeze's to notice, not this module's. Widening it is a
|
||||
card, with a rig campaign behind it, not an edit.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
STATE, TRIP AND LATCH
|
||||
|
||||
@@ -198,6 +293,178 @@ from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
|
||||
# SAFETY-30. CFG-03: THE ONE IN-CODE COPY OF THE FOUR MULTI-INVERTER DEFAULTS.
|
||||
# `config.yaml`'s `options:` block is the source of truth an operator edits and
|
||||
# the Supervisor reads, and `schema:` holds the bounds. This dict exists for the
|
||||
# reason `circulation.CIRC_OPTION_DEFAULTS` and `maintenance.MAINT_OPTION_DEFAULTS`
|
||||
# do - the Dockerfile does not put config.yaml in the image, so the running
|
||||
# add-on cannot read it - and `test_watchdog.py` pins the two together by READING
|
||||
# config.yaml, so a drift goes red in CI rather than shipping.
|
||||
#
|
||||
# ⚠️ EVERY KEY HERE IS DEAD AT A ROSTER OF ONE, and that is the point rather
|
||||
# than a caveat. `Controller._arm_sign_watchdogs()` arms the single unit's
|
||||
# detector against the meter with the SHIPPED `sign_disagree_w` /
|
||||
# `sign_disagree_s`, which are read in main.py exactly where they always were
|
||||
# and are not in this dict. Nothing below is consulted until a second inverter
|
||||
# exists.
|
||||
SIGN_OPTION_DEFAULTS = {
|
||||
# --- THE MAGNITUDE GATE, AND IT IS NOT SAFETY-02's 300 W BY ACCIDENT ---
|
||||
# ⚠️ DERIVED FROM `control.Tuning.saturation_w`, WHICH IS 500 W, AND THE
|
||||
# DERIVATION IS THE POINT. This check gates on BOTH sides being over
|
||||
# `min_w`, so the smallest divergence it can ever see between a command and
|
||||
# the power that command produced is `2 * min_w` - the two are OPPOSED, so
|
||||
# the gap is the sum of the magnitudes. At 250 W that is exactly 500 W: the
|
||||
# gap at which `compute()`'s own anti-windup test already concludes THE
|
||||
# INVERTER IS NOT FOLLOWING and freezes the integrator. So this watchdog
|
||||
# cannot fire on a divergence the shipped control law itself calls ordinary
|
||||
# tracking, and the two guards meet at a number rather than overlapping in a
|
||||
# band nobody has drawn.
|
||||
#
|
||||
# MEASURED, on 1890 closed-loop two-inverter runs in which NOTHING is faulty
|
||||
# (every unit executes the share the allocator gave it), swept over the
|
||||
# WHOLE range config.yaml accepts for `gain` float(0.05,1.0) and `slew_w`
|
||||
# int(50,5000), across both families of stimulus that can produce legitimate
|
||||
# opposition. Worst CONTINUOUS opposition between a unit's standing command
|
||||
# and its own 0x0518 power, as a function of this threshold:
|
||||
#
|
||||
# 50 W -> 25.0 s 250 W -> 10.0 s 700 W -> 5.0 s
|
||||
# 150 W -> 15.0 s 300 W -> 10.0 s 1000 W -> 0.0 s
|
||||
# 200 W -> 15.0 s 500 W -> 5.0 s
|
||||
#
|
||||
# ⚠️ AND THE CURVE IS FLAT, WHICH IS THE FINDING THAT DECIDED THE SHAPE OF
|
||||
# THIS PAIR. Unlike the site comparison - where the meter is driven by the
|
||||
# LOAD and a flapping load holds it opposed for minutes - a unit's own power
|
||||
# CHASES ITS OWN COMMAND through a bounded ramp and a first-order lag, so the
|
||||
# opposition can only last as long as the crossing does. Dropping the
|
||||
# threshold from 300 W to 50 W buys 15 s of extra transient and nothing else.
|
||||
# The work is therefore done by the WINDOW below, and this number is set
|
||||
# where the control law already draws its line rather than being tuned.
|
||||
#
|
||||
# The largest opposed magnitude seen anywhere in those 1890 runs is 875 W;
|
||||
# a threshold above that would gate NOTHING legitimate in at all, and is
|
||||
# rejected because it would also be blind to a unit reversing a 900 W share.
|
||||
"unit_sign_disagree_w": 250,
|
||||
|
||||
# --- THE WINDOW -------------------------------------------------------
|
||||
# Three bounds, and the value clears all three.
|
||||
#
|
||||
# LOWER, from the rig: 10.0 s - two control cycles, the worst CONTINUOUS
|
||||
# legitimate opposition above 250 W across all 1890 runs. It is a
|
||||
# reversing site whose second write lands a cycle after the first, both
|
||||
# units then slewing through zero behind a 10 s lag; nothing is wrong.
|
||||
#
|
||||
# LOWER, from the firmware: `inverter.LINK_STALE_S`, 30 s. A unit not
|
||||
# executing its share for less than the firmware's own veto window is a
|
||||
# LINK fault, and the add-on already answers it - liveness drops the unit
|
||||
# and the survivors carry its share, with the record saying so. Firing
|
||||
# inside that window would raise a second, louder alarm about a state
|
||||
# already being handled, which is the SAFETY-15/SAFETY-19 failure exactly.
|
||||
#
|
||||
# UPPER, from SAFETY-02 itself: 180 s, the SITE hold. A unit that is not
|
||||
# doing what it was told must not be parked LATER than the site would be
|
||||
# parked for the same watts, and unlike the site comparison this one needs
|
||||
# nothing to net out before it can conclude - the evidence is complete on
|
||||
# the first cycle it appears.
|
||||
#
|
||||
# 85 s: seventeen control cycles - 8.5x the worst legitimate episode this
|
||||
# rig can produce, 2.8x the firmware's own veto window, and under HALF the
|
||||
# site hold. ⚠️ IT IS DELIBERATELY NOT 60, 75, 90, 120 OR 180. A round
|
||||
# number here would be a guess wearing a measurement's clothes, and the
|
||||
# three bounds above are what the number has to answer to.
|
||||
#
|
||||
# ⚠️ AND INVERTER B DOES NOT PHYSICALLY EXIST. Its ramp and lag in the rig
|
||||
# are inverter A's, COPIED, carrying `measured=False` - SPIKE-04 measures
|
||||
# the real ones. A slower second unit lengthens every crossing above, which
|
||||
# is what the 8.5x buys headroom for. SPIKE-04 is the revisit trigger for
|
||||
# both numbers here, not a reason to move them now.
|
||||
"unit_sign_disagree_s": 85,
|
||||
|
||||
# --- THE SITE COMPARISON AT N>=2, AND IT IS NOT THE SHIPPED PAIR -------
|
||||
# ⚠️ THE THRESHOLD IS CARRIED AND THE WINDOW IS NOT, WHICH IS A FINDING
|
||||
# RATHER THAN A COMPROMISE. Only one of the two arguments behind 300 W /
|
||||
# 180 s depends on how many inverters the site has:
|
||||
#
|
||||
# THE THRESHOLD is about NOISE. "Near zero the sign is noise, and near
|
||||
# zero is where a healthy loop LIVES" - the deadband holds the command
|
||||
# still while the meter wanders either side of `target_grid_w`. The
|
||||
# deadband is 15 W and P1 is one meter whatever the roster, so nothing
|
||||
# about that argument moves. 300 W, carried - and the two-inverter
|
||||
# campaign says the carry is safe rather than merely convenient: in the
|
||||
# load-reversal family the site figure ever goes opposed AND over 300 W in
|
||||
# 994 of 1050 runs at two inverters and 955 of 1050 at one. The gate opens
|
||||
# about as often either way; what changed is how LONG it stays open, which
|
||||
# is the window's problem and not the threshold's.
|
||||
#
|
||||
# THE WINDOW is about a TRANSIENT, and the transient scales with the site.
|
||||
# The measured worst legitimate case is a load reversal that the loop
|
||||
# crosses zero slowly: the command has to travel the whole rail at
|
||||
# `slew_w` per cycle, and at N>=2 the rail is `Controller.site_max_w` - the
|
||||
# ROSTER SUM - while `slew_w` is unchanged. So the crossing takes about
|
||||
# twice as long at two inverters as at one, and that is exactly what the
|
||||
# rig measures.
|
||||
#
|
||||
# 1890 closed-loop runs in which nothing is faulty, the SAME campaign the
|
||||
# per-unit pair above is read off, run at BOTH rosters as its own control.
|
||||
# Worst CONTINUOUS opposition between the standing command(s) and the meter,
|
||||
# LOAD-REVERSAL family, at a 300 W threshold:
|
||||
#
|
||||
# N=1 (the shipped comparison) 110.0 s - inside 180 s, 1.6x
|
||||
# N=2 (the sum, same stimuli) 215.0 s - OVER 180 s
|
||||
#
|
||||
# ⚠️ SO CARRYING 180 s WOULD HAVE SHIPPED A FALSE TRIP, and it is a config a
|
||||
# schema-legal install can reach: `gain` 0.05 and `slew_w` 50 are both the
|
||||
# floor of what config.yaml accepts, and a +-2200 W load reversal is an oven
|
||||
# and a heat pump. That is the number this card exists to not assume.
|
||||
#
|
||||
# 325 s: 1.51x the measured worst, well inside the 900 s quarter that bills
|
||||
# the capacity tariff, and still inside every episode the fault day
|
||||
# contains - 2026-08-20's four clusters run 16, 30, 77 and 77 minutes and
|
||||
# its opposed runs reach 1750 s, so a 325 s window fires in all of them.
|
||||
# What it costs is stated rather than hidden: about two and a half extra
|
||||
# minutes of wrong-direction SITE power before the stop, bought to remove a
|
||||
# false trip that a legal configuration produces. ⚠️ DELIBERATELY NOT 300 OR
|
||||
# 360; the measurement is what it answers to.
|
||||
#
|
||||
# ⚠️ AND IT IS NOT THE PER-UNIT WINDOW EITHER, IN THE OTHER DIRECTION. The
|
||||
# per-unit comparison is 85 s because a unit's own power CHASES ITS OWN
|
||||
# COMMAND and the transient is two cycles; the site comparison is 325 s
|
||||
# because the meter is driven by the LOAD and the transient is the loop
|
||||
# crossing zero. Same predicate, two instruments, two windows, both measured.
|
||||
"site_sign_disagree_w": 300,
|
||||
"site_sign_disagree_s": 325,
|
||||
}
|
||||
|
||||
# ⚠️ A LIMIT OF THE SITE COMPARISON THAT SAFETY-30 DID NOT INTRODUCE AND DOES
|
||||
# NOT FIX, RECORDED HERE BECAUSE THE CAMPAIGN FOUND IT AND SILENCE WOULD BE
|
||||
# WORSE. The rig's other stimulus family is a FLAPPING LOAD, and a square wave
|
||||
# whose half period is about one control cycle opposes the command on EVERY
|
||||
# cycle: the command chases the previous half-cycle's meter while the meter has
|
||||
# already reversed. Across the 840 flapping runs the worst continuous opposition
|
||||
# at a 300 W threshold is 980 s at two inverters - and 1000 s at ONE, which is
|
||||
# the whole point. The N=1 arm is the control, and it says this is a property of
|
||||
# comparing a lagged command against a meter, not a property of the second
|
||||
# inverter. No window inside the 900 s billing quarter survives it, and no
|
||||
# threshold up to 1000 W does either.
|
||||
#
|
||||
# It is not acted on here for three reasons, in order of weight: it is identical
|
||||
# at the roster this add-on actually ships, so acting on it would be changing a
|
||||
# live safety path on evidence that has nothing to do with this card; a
|
||||
# ~6 kW square wave at 0.1 Hz sustained for a quarter of an hour is not a house
|
||||
# (the captured healthy day's longest opposed run is 30 s); and the fix is not a
|
||||
# number - it wants the detector to notice that the disagreement is ALTERNATING,
|
||||
# which is a different check. It is a card, and this comment is its evidence.
|
||||
|
||||
# SAFETY-30. THE TWO NOUNS THE TRIP SENTENCE CAN NAME, WRITTEN ONCE. They are
|
||||
# constants rather than literals at the call sites because `main.py` arms the
|
||||
# detectors and `test_watchdog.py` grades what they say, and a string typed in
|
||||
# two places is a string that drifts in one of them - the same argument
|
||||
# `store.unit_key()` makes about a key name. `AGAINST_METER` is the wording that
|
||||
# has always shipped and must not change: it is what a one-inverter install's
|
||||
# `reason` reads, in the store, in the action log and on the status page.
|
||||
AGAINST_METER = "a meter reading"
|
||||
AGAINST_OWN_POWER = "its own measured power"
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class SignWatchdogConfig:
|
||||
"""Defaults, not constants - config.yaml carries both (SAFETY-02 AC 5)."""
|
||||
@@ -206,7 +473,7 @@ class SignWatchdogConfig:
|
||||
hold_s: float = 180.0
|
||||
|
||||
|
||||
def disagrees(commanded_w, grid_w, following: bool,
|
||||
def disagrees(commanded_w, against_w, following: bool,
|
||||
cfg: SignWatchdogConfig) -> bool:
|
||||
"""The predicate, and the ONLY place it is written down.
|
||||
|
||||
@@ -215,12 +482,23 @@ def disagrees(commanded_w, grid_w, following: bool,
|
||||
inline. Two copies of a safety predicate is one copy plus a future
|
||||
disagreement about what the check means, and the copy that drifts is always
|
||||
the one in the harness that grades it.
|
||||
|
||||
⚠️ `against_w` WAS CALLED `grid_w`, AND THE RENAME IS THE WHOLE OF SAFETY-30
|
||||
IN ONE PARAMETER. The arithmetic is unchanged - opposed signs, neither side
|
||||
near zero, and the loop actually driving - but WHAT the command is opposed
|
||||
TO is now a property of the caller rather than a fact about this function.
|
||||
The site comparison hands it the meter; each unit's own comparison hands it
|
||||
that unit's measured power (register 0x0518). One predicate, two callers,
|
||||
for `loop_is_following()`'s reason: a safety predicate written down twice is
|
||||
one copy plus a future disagreement about what the check means. The
|
||||
parameter is positional at every call site in both repositories, so the
|
||||
rename moves no caller.
|
||||
"""
|
||||
return (following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and commanded_w is not None and against_w is not None
|
||||
and commanded_w * against_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w)
|
||||
and abs(against_w) > cfg.min_w)
|
||||
|
||||
|
||||
def loop_is_following(resolution, loop_asked) -> bool:
|
||||
@@ -272,7 +550,17 @@ def loop_is_following(resolution, loop_asked) -> bool:
|
||||
|
||||
|
||||
class SignWatchdog:
|
||||
"""One instance per actuator, evaluated once per control cycle.
|
||||
"""One instance per COMPARISON, evaluated once per control cycle.
|
||||
|
||||
⚠️ SINCE SAFETY-30 THAT IS NOT THE SAME SENTENCE AS "one per actuator",
|
||||
which is what this docstring used to say. There is one instance per
|
||||
inverter - `Inverter.sign_wd`, latched under that unit's own store keys -
|
||||
AND one for the site, `Controller.site_sign_wd`, latched under flat ones.
|
||||
The two ask different questions of different evidence and reach different
|
||||
remedies; `arm()` below is where an instance is told which of them it is.
|
||||
At a roster of one they would be the same question, so only the per-unit
|
||||
instance is ever armed there - see the SAFETY-30 section of the module
|
||||
docstring.
|
||||
|
||||
⚠️ NOT SHARED ACROSS CADENCES. `disagree_since` is a wall-clock start time,
|
||||
so driving one instance from two loops at two rates would have each one
|
||||
@@ -282,8 +570,14 @@ class SignWatchdog:
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None, *,
|
||||
tripped: bool = False, reason: str = ""):
|
||||
tripped: bool = False, reason: str = "",
|
||||
against: str = AGAINST_METER):
|
||||
self.cfg = cfg or SignWatchdogConfig()
|
||||
# SAFETY-30. WHAT THE COMMAND IS BEING COMPARED AGAINST, as the operator
|
||||
# reads it in the trip sentence. The default is the meter, which is what
|
||||
# every trip this add-on has ever taken was compared against and is what
|
||||
# keeps a one-inverter install's `reason` string byte-identical.
|
||||
self.against = str(against)
|
||||
self.disagree_since: datetime | None = None
|
||||
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED. A latch that lives only in
|
||||
# memory is not a latch: a container restart clears it, and the add-on
|
||||
@@ -292,8 +586,31 @@ class SignWatchdog:
|
||||
self.tripped = bool(tripped)
|
||||
self.reason = reason if self.tripped else ""
|
||||
|
||||
# -- which of SAFETY-30's two questions this instance is asking ----------
|
||||
def arm(self, cfg: SignWatchdogConfig, against: str) -> None:
|
||||
"""Set the thresholds and the subject of the comparison. Nothing else.
|
||||
|
||||
⚠️ IT IS CONFIGURATION, NOT STATE, AND IT DELIBERATELY DOES NOT TOUCH
|
||||
`disagree_since`, `tripped` OR `reason`. A detector that cleared its own
|
||||
window when it was told what it was comparing against would lose the
|
||||
episode it is in the middle of, every cycle, and would never accumulate
|
||||
a hold at all - the check would be permanently green and nothing would
|
||||
say so.
|
||||
|
||||
⚠️ AND IT IS RE-STATED EVERY CYCLE RATHER THAN FROZEN AT CONSTRUCTION.
|
||||
The answer is a property of the ROSTER and of nothing else, and
|
||||
`Controller.cycle()` already re-reads the roster every cycle for
|
||||
liveness and for the allocation. Freezing it in `__init__` would also
|
||||
make it wrong for any caller that appends an inverter afterwards, which
|
||||
is exactly how a two-inverter fixture is built in this repository - and
|
||||
a fixture that silently got the one-inverter comparison would grade
|
||||
nothing while looking green.
|
||||
"""
|
||||
self.cfg = cfg
|
||||
self.against = str(against)
|
||||
|
||||
# -- the whole check, and it is a pure function of its arguments ----------
|
||||
def evaluate(self, commanded_w, grid_w, following: bool,
|
||||
def evaluate(self, commanded_w, against_w, following: bool,
|
||||
now: datetime) -> bool:
|
||||
"""Advance the detector one cycle. Returns True while tripped.
|
||||
|
||||
@@ -301,15 +618,23 @@ class SignWatchdog:
|
||||
after deadband, slew, quantisation and the arbiter. Not
|
||||
the optimizer's raw wish: the wire carries the emitted
|
||||
value, so anything else can disagree with the meter for a
|
||||
reason that is not a fault.
|
||||
`grid_w` net P1, + = importing. None when the meter is stale or
|
||||
missing, which CLEARS the timer rather than accumulating
|
||||
- a frozen figure held against a moving command would
|
||||
otherwise manufacture a disagreement in about three
|
||||
minutes, on top of SAFETY-01 having already commanded
|
||||
zero for the same cause.
|
||||
reason that is not a fault. For a per-unit instance it is
|
||||
THAT UNIT'S share of it; for the site instance it is the
|
||||
roster sum.
|
||||
`against_w` what the command is graded against, and SAFETY-30 made
|
||||
this a decision rather than a fact: net P1 for the SITE
|
||||
comparison (+ = importing), and this unit's own measured
|
||||
power for the PER-UNIT one (+ = discharging, register
|
||||
0x0518). Both carry the same sign convention as the
|
||||
command, which is why one predicate serves both. None
|
||||
when the reading is stale or missing, which CLEARS the
|
||||
timer rather than accumulating - a frozen figure held
|
||||
against a moving command would otherwise manufacture a
|
||||
disagreement in about three minutes, on top of SAFETY-01
|
||||
having already commanded zero for the same cause.
|
||||
`following` did the grid-following loop actually win this cycle? See
|
||||
gate 1 in the module docstring.
|
||||
gate 1 in the module docstring, and the SAFETY-30 section
|
||||
on why the per-unit comparison keeps it.
|
||||
`now` the caller's clock, so this stays testable and replayable.
|
||||
"""
|
||||
if self.tripped:
|
||||
@@ -317,7 +642,7 @@ class SignWatchdog:
|
||||
return True
|
||||
|
||||
cfg = self.cfg
|
||||
if not disagrees(commanded_w, grid_w, following, cfg):
|
||||
if not disagrees(commanded_w, against_w, following, cfg):
|
||||
self.disagree_since = None
|
||||
return False
|
||||
|
||||
@@ -330,9 +655,17 @@ class SignWatchdog:
|
||||
return False
|
||||
|
||||
self.tripped = True
|
||||
# ⚠️ `self.against` IS THE ONLY THING SAFETY-30 CHANGED IN THIS STRING,
|
||||
# and it defaults to the wording that shipped - "a meter reading" - so a
|
||||
# one-inverter install's `reason` is byte-identical to what an operator
|
||||
# (and test_watchdog.py) has always read. A per-unit instance names what
|
||||
# it actually compared instead, because "commanded +1500 W against a
|
||||
# meter reading -1500 W" would be a false statement about which
|
||||
# instrument produced the evidence, on the one line somebody woken by
|
||||
# this alarm reads first.
|
||||
self.reason = (
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against a meter "
|
||||
f"reading {grid_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against "
|
||||
f"{self.against} {against_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"(limits: both over {cfg.min_w:.0f} W, held over {cfg.hold_s:.0f} s)"
|
||||
)
|
||||
return True
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.5.2"
|
||||
version: "0.6.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -39,6 +39,59 @@ options:
|
||||
batt_invert: false
|
||||
setpoint_entity: ""
|
||||
|
||||
# --- ARCH-01 / CFG-04: the inverter roster ---------------------------------
|
||||
# ⚠️ EMPTY IS NOT "UNCONFIGURED", IT IS THE SINGLE-INVERTER CONFIGURATION, and
|
||||
# it is what every install that upgrades into this version lands on. An empty
|
||||
# list means THE FIVE FLAT KEYS ABOVE DESCRIBE THE ONE INVERTER - same
|
||||
# entities, same rating, same behaviour, no operator action - which is the
|
||||
# only migration story this key was allowed to have. `build_roster()` reads
|
||||
# this and nothing else decides the shape.
|
||||
#
|
||||
# Declared, it REPLACES those five keys rather than extending them. Each entry
|
||||
# names its own actuator, its own rating and its own sensors:
|
||||
#
|
||||
# inverters:
|
||||
# - name: inverter-a
|
||||
# setpoint_entity: number.goodwe_a_setpoint_w
|
||||
# soc_entity: sensor.goodwe_a_soc
|
||||
# batt_entity: sensor.goodwe_a_battery_power
|
||||
# max_w: 5000
|
||||
# - name: inverter-b
|
||||
# setpoint_entity: number.goodwe_b_setpoint_w
|
||||
# soc_entity: sensor.goodwe_b_soc
|
||||
# batt_entity: sensor.goodwe_b_battery_power
|
||||
# max_w: 3000
|
||||
#
|
||||
# ⚠️ NOTHING IS INHERITED FROM THE FLAT KEYS BY AN ENTRY THAT OMITS IT, and
|
||||
# that is the whole of DEV-02 restated as a config rule. `soc`, `batt` and the
|
||||
# rating became per-instance precisely so that no inverter is ever graded
|
||||
# against a sibling's numbers; an entry silently inheriting `soc_entity` would
|
||||
# rebuild that defect in YAML. `name`, `setpoint_entity` and `max_w` are
|
||||
# therefore REQUIRED of every entry (the schema below enforces it, and
|
||||
# validate.py rule 9 enforces it again for the callers the Supervisor never
|
||||
# sees). An omitted `soc_entity`/`batt_entity` means THIS UNIT HAS NO SUCH
|
||||
# SENSOR - `inputs_ok` already stops the site for that - and never means
|
||||
# "use the other one's".
|
||||
#
|
||||
# ⚠️ AND THE FLAT `setpoint_entity` MUST THEN BE BLANK. Leaving it set while a
|
||||
# roster is declared is two config sites aimed at actuators, one of which
|
||||
# nothing writes; if it names an entity an entry also names, SAFETY-28's
|
||||
# writer census refuses it as two writers on one actuator, and if it names a
|
||||
# different one the add-on would run a site quietly smaller than the config
|
||||
# reads. Rule 9 refuses both rather than picking one.
|
||||
#
|
||||
# ⚠️ THE SHAPE WAS MEASURED, NOT ASSUMED. A list of objects is not used
|
||||
# anywhere else in this file, and whether Supervisor's options validator
|
||||
# accepts one was an open question - `static_profile` carries its structure as
|
||||
# a JSON string in a `str?` for exactly that doubt. It was settled by running
|
||||
# Supervisor 2026.08.0's OWN `AppOptions` validator (the version this site
|
||||
# runs) against both candidates: tools/supervisor_shape_probe.py is the
|
||||
# script, DECISIONS/CFG-04-inverter-roster.md is what it printed and why the
|
||||
# list won. The default `[]` is load-bearing in that record: WITHOUT it the
|
||||
# validator answers `Missing option 'inverters' in root` for every existing
|
||||
# options blob, and the upgrade leaves an add-on that cannot start.
|
||||
inverters: []
|
||||
|
||||
# --- P1 meter ingestion (specs §5.2 / §14 `meter:`) -------------------------
|
||||
# `off` keeps the original single meter_entity path above, so an existing
|
||||
# install is untouched until it opts in. ha_dsmr subscribes to the DSMR
|
||||
@@ -114,6 +167,62 @@ options:
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- SAFETY-30 per-inverter sign-disagreement watchdog ---------------------
|
||||
# ⚠️ A DIFFERENT COMPARISON, NOT A SECOND COPY OF THE ONE ABOVE, AND IT IS
|
||||
# ARMED ONLY WHEN THIS SITE HAS MORE THAN ONE INVERTER. The pair above grades
|
||||
# the SITE's total command against P1 - one meter, one grid connection. This
|
||||
# pair grades EACH inverter's own share against THAT inverter's own measured
|
||||
# power (holding register 0x0518), and it catches the fault the meter cannot
|
||||
# answer for once there are two units: a unit doing the opposite of what it
|
||||
# was told, while its sibling covers for it and P1 reads exactly what a
|
||||
# healthy site reads.
|
||||
#
|
||||
# At ONE inverter these two keys do nothing at all. §6.2's identity makes the
|
||||
# site's total command that inverter's command, so the pair above is already
|
||||
# asking this question of the same actuator, and arming a second detector
|
||||
# would be two latches and two banners for one fault.
|
||||
#
|
||||
# Both defaults are measured on admin/goodwe's two-master rig, over 1890
|
||||
# closed-loop runs in which nothing is faulty, swept across the whole range
|
||||
# this file accepts for `gain` and `slew_w`. 250 W is `saturation_w / 2`, so
|
||||
# the smallest divergence this can see is exactly the gap at which the control
|
||||
# law itself already says the inverter is not following; 85 s is 8.5x the
|
||||
# worst legitimate opposition those runs produce (10.0 s), 2.8x the firmware's
|
||||
# own 30 s link veto, and under half the 180 s the site check takes. See
|
||||
# app/watchdog.py's SIGN_OPTION_DEFAULTS and
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md.
|
||||
#
|
||||
# ⚠️ unit_sign_disagree_w must stay BELOW max_w, for sign_disagree_w's reason:
|
||||
# a share is bounded to +-max_w, so a threshold at or above it can never fire.
|
||||
# validate.py refuses that config.
|
||||
unit_sign_disagree_w: 250
|
||||
unit_sign_disagree_s: 85
|
||||
|
||||
# --- SAFETY-30 SITE sign-disagreement watchdog -----------------------------
|
||||
# ⚠️ THE SAME COMPARISON `sign_disagree_*` MAKES, AT THE ROSTER WHERE IT STOPS
|
||||
# BEING A STATEMENT ABOUT ONE INVERTER. At two or more units the SUM of the
|
||||
# standing commands is graded against P1, and the trip stops the whole site -
|
||||
# what it catches is the site being asked for the wrong thing, which every
|
||||
# per-inverter check is blind to because each unit is faithfully executing its
|
||||
# share. At ONE inverter these two keys do nothing: `sign_disagree_*` above is
|
||||
# already asking this of the same actuator.
|
||||
#
|
||||
# The threshold is the shipped 300 W, CARRIED, and the reason is that the
|
||||
# argument behind it does not depend on the roster: near zero the sign is
|
||||
# noise, the deadband is 15 W, and there is one P1 whatever is behind it.
|
||||
#
|
||||
# ⚠️ THE WINDOW IS NOT CARRIED, AND THAT IS A MEASUREMENT. The transient 180 s
|
||||
# exists to reject is the loop crossing zero after a load reversal, and the
|
||||
# command has to travel the whole SITE rail at `slew_w` per cycle - a rail
|
||||
# that is the roster sum while `slew_w` is not. On 1890 two-inverter runs in
|
||||
# which nothing is faulty, the worst continuous legitimate opposition at 300 W
|
||||
# is 110 s at one inverter and 215 s at two: carrying 180 s across would have
|
||||
# shipped a false trip reachable at `gain: 0.05`, `slew_w: 50` and an ordinary
|
||||
# 2.2 kW load reversal. 325 s is 1.51x that, inside the 900 s billing quarter,
|
||||
# and still inside every episode of the 2026-08-20 fault day.
|
||||
site_sign_disagree_w: 300
|
||||
site_sign_disagree_s: 325
|
||||
|
||||
# --- SAFETY-18 frozen-but-fresh meter detector -----------------------------
|
||||
# Seconds the meter may keep answering with an UNCHANGED measurement while the
|
||||
# command stands at the rail before the add-on raises an alarm. Both halves
|
||||
@@ -134,6 +243,25 @@ options:
|
||||
# still inside the 900 s quarter that bills the capacity tariff.
|
||||
meter_freeze_s: 300
|
||||
|
||||
# --- SAFETY-31: circulating power ------------------------------------------
|
||||
# ⚠️ CFG-03. THESE TWO LINES ARE THE SOURCE OF TRUTH FOR THESE DEFAULTS, and
|
||||
# `app/circulation.py`'s `CIRC_OPTION_DEFAULTS` is the ONE in-code copy - the
|
||||
# Dockerfile does not put this file in the image, so the running add-on cannot
|
||||
# read it. test_watchdog.py pins the copy by READING these lines, so a drift
|
||||
# goes red in CI rather than shipping. Add a third option in three places -
|
||||
# options:, schema:, CIRC_OPTION_DEFAULTS - and in no fourth.
|
||||
#
|
||||
# Circulating power is sum(|Bi|) - |sum(Bi)| over MEASURED per-inverter power:
|
||||
# two inverters pushing against each other, which NETS TO ZERO AT THE METER
|
||||
# and is therefore invisible to every other guard in this add-on. Both numbers
|
||||
# below were measured on the TEST-19 two-master rig over 924 closed-loop runs
|
||||
# in which nothing was faulty; circulation.py carries the curve they were read
|
||||
# off and the argument for each. They are NOT sensitivity preferences.
|
||||
#
|
||||
# Both are ignored at one inverter, where the quantity is identically zero.
|
||||
circulation_w: 700
|
||||
circulation_hold_s: 75
|
||||
|
||||
# --- maintenance -----------------------------------------------------------
|
||||
# ⚠️ CFG-03. THESE EIGHT LINES ARE THE SOURCE OF TRUTH FOR THE MAINTENANCE
|
||||
# DEFAULTS. The Supervisor reads this file and the operator edits this file,
|
||||
@@ -350,6 +478,32 @@ schema:
|
||||
batt_invert: bool
|
||||
setpoint_entity: str
|
||||
|
||||
# CFG-04. THE ONE LIST-OF-OBJECTS IN THIS FILE, and see the options block for
|
||||
# the measurement that says Supervisor 2026.08.0 accepts it: nested types are
|
||||
# enforced per entry, a missing required key names the key, a scalar where the
|
||||
# list belongs is refused, and the UI renders it as a repeatable section.
|
||||
#
|
||||
# ⚠️ THREE KEYS ARE REQUIRED PER ENTRY AND THAT IS DELIBERATE. An entry with
|
||||
# no `name` has no Store namespace and would share another unit's SAFETY-02
|
||||
# latch; one with no `setpoint_entity` is a unit nothing can command; one with
|
||||
# no `max_w` would have to borrow a rating, which is the sibling-grading
|
||||
# defect DEV-02 removed. The optional pair is the sensors, whose absence
|
||||
# honestly means "this unit reports none".
|
||||
#
|
||||
# ⚠️ THIS BLOCK IS DECLARED BEFORE `max_w:` ON PURPOSE. `max_w` now appears
|
||||
# TWICE under `schema:` - once nested here, once flat below - and a reader
|
||||
# that matches a stripped line takes the nested one FIRST. That is the
|
||||
# first-match trap this card had to fix in three checks; leaving the nesting
|
||||
# first keeps the trap baited, so the fix stays graded rather than assumed.
|
||||
# test_inverter.py part 12 asserts the ordering is still hostile.
|
||||
inverters:
|
||||
- name: str
|
||||
setpoint_entity: str
|
||||
max_w: int(100,5000)
|
||||
soc_entity: str?
|
||||
batt_entity: str?
|
||||
batt_invert: bool?
|
||||
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1|ha_signed|homewizard_local)
|
||||
# ⚠️ 2 is accepted by this range but is not a real Belgian connection. A
|
||||
# telegram whose phase count disagrees is rejected at ingest and logged, so a
|
||||
@@ -389,6 +543,33 @@ schema:
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
# SAFETY-30. No "off" value, for SAFETY-02's reason.
|
||||
#
|
||||
# ⚠️ THE THRESHOLD'S RANGE IS THE SAME AS THE SITE CHECK'S ON PURPOSE, AND THE
|
||||
# WINDOW'S FLOOR IS NOT. On the two-inverter rig the per-unit comparison's
|
||||
# worst continuous legitimate opposition is nearly FLAT in the threshold -
|
||||
# 25.0 s at 50 W, 15.0 s at 150 W, 10.0 s at 250 W, 5.0 s at 500 W - because a
|
||||
# unit's own power chases its own command rather than the load. So no value in
|
||||
# this range puts the guard outside the regime it can be answered for, and the
|
||||
# floor does not have to be a knee the way `circulation_w`'s does.
|
||||
unit_sign_disagree_w: int(50,5000)
|
||||
# The floor of 30 is `inverter.LINK_STALE_S`, the firmware's own veto window:
|
||||
# below it, a unit not executing its share is a LINK fault the add-on already
|
||||
# answers by dropping the unit from the split, and firing inside that window
|
||||
# would be a second, louder alarm about a state that is already being handled.
|
||||
unit_sign_disagree_s: int(30,1800)
|
||||
|
||||
# SAFETY-30's SITE pair. Same ranges as `sign_disagree_*`, because it is the
|
||||
# same comparison asked of the site total - and no "off" value, for the same
|
||||
# reason. ⚠️ THERE IS DELIBERATELY NO validate.py RULE PAIRING
|
||||
# site_sign_disagree_w WITH max_w, unlike the other two thresholds: the bound
|
||||
# on the SITE command is `Controller.site_max_w`, the ROSTER SUM, and
|
||||
# `validate_startup_config()` is handed options rather than a roster. A rule
|
||||
# written against max_w would refuse a perfectly reachable two-inverter
|
||||
# configuration the day CFG-04 lands. The schema range is the bound here.
|
||||
site_sign_disagree_w: int(50,5000)
|
||||
site_sign_disagree_s: int(30,1800)
|
||||
|
||||
# No "off" value, for SAFETY-02's reason: disarming a safety alarm is not a
|
||||
# supported configuration. ⚠️ THE FLOOR OF 60 IS NOT A RECOMMENDATION. At 300 s
|
||||
# the slowest a HEALTHY meter's 1 Wh register can tick and still look unchanged
|
||||
@@ -398,6 +579,28 @@ schema:
|
||||
# app/freeze.py.
|
||||
meter_freeze_s: int(60,3600)
|
||||
|
||||
# SAFETY-31. No "off" value, for SAFETY-02's and meter_freeze_s's reason:
|
||||
# disarming a safety alarm is not a supported configuration.
|
||||
#
|
||||
# ⚠️ THE FLOOR OF 400 IS NOT A RECOMMENDATION, IT IS THE MEASURED EDGE OF THE
|
||||
# REGIME IN WHICH THIS GUARD CAN BE ANSWERED FOR. On the TEST-19 rig, the
|
||||
# worst CONTINUOUS opposition produced by a site where nothing is faulty - a
|
||||
# flapping load reversing every control cycle, swept over the whole range this
|
||||
# schema accepts for `gain` and `slew_w` - is 5.0 s at a 400 W threshold and
|
||||
# above, 10.0 s at 300 W, 40.0 s at 250 W and 505.0 s at 100 W. Below the
|
||||
# knee, legitimate operation holds the sensor over the threshold for MINUTES
|
||||
# and no window shorter than the 900 s billing quarter could tell that from a
|
||||
# fault. A configurable value under 400 W would be a false-alarm generator
|
||||
# that this project's own doctrine (SAFETY-15, SAFETY-19) forbids shipping.
|
||||
circulation_w: int(400,5000)
|
||||
# The floor of 30 is `inverter.LINK_STALE_S`: below the firmware's own veto
|
||||
# window a unit still executing a stale share is a LINK fault the add-on
|
||||
# already handles by dropping it from the split, and firing inside that window
|
||||
# would raise a second, louder alarm about a state already being managed. The
|
||||
# ceiling of 900 is the quarter that bills the capacity tariff - a circulating
|
||||
# loop must be caught and acted on well inside one.
|
||||
circulation_hold_s: int(30,900)
|
||||
|
||||
# ⚠️ CFG-03 - THIS IS WHERE A RANGE LIVES, AND THE ONLY PLACE IT LIVES. The
|
||||
# `options:` block above holds the DEFAULT; this block holds the BOUNDS, and
|
||||
# `MAINT_OPTION_DEFAULTS` deliberately mirrors the former and not the latter -
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
@@ -13,10 +13,13 @@ Read MUTATION.md before you report a survivor.
|
||||
"""
|
||||
|
||||
import sys
|
||||
from math import inf
|
||||
|
||||
from app.arbiter import (
|
||||
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY,
|
||||
Claim, resolve,
|
||||
ACTUATOR_SITE, CLAIM_SCOPE, P_ARBITRAGE, P_LOOP, P_MAINT_SHAPE,
|
||||
P_MAINTENANCE, P_PEAK, P_SAFETY, SCOPE_SITE, SCOPE_UNIT, UnitBounds,
|
||||
Claim, actuator_for, allocate, pre_resolve, resolve, scope_violations,
|
||||
site_resolve,
|
||||
)
|
||||
|
||||
fails = []
|
||||
@@ -28,6 +31,15 @@ def check(name, cond):
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def _raises(fn):
|
||||
"""True if `fn()` raises - a check that something is REFUSED, not defaulted."""
|
||||
try:
|
||||
fn()
|
||||
except Exception:
|
||||
return True
|
||||
return False
|
||||
|
||||
|
||||
print("basics")
|
||||
r = resolve([])
|
||||
check("no claims at all means 0 W", r.target_w == 0.0 and r.winner == "failsafe")
|
||||
@@ -99,6 +111,399 @@ check("charging is clamped by the low limit", r.target_w == -1000)
|
||||
r = resolve([Claim.set("loop", P_LOOP, -200), charge_only])
|
||||
check("charge-only permits charging", r.target_w == -200)
|
||||
|
||||
# =============================================================================
|
||||
# ARB-03: the actuator specs.md declared, and the three stages
|
||||
# =============================================================================
|
||||
# ⚠️ EVERY CHECK ABOVE THIS LINE IS UNEDITED, AND THAT IS ITSELF THE FIRST
|
||||
# ACCEPTANCE CRITERION. Not one of them names an actuator, so every claim they
|
||||
# build is a SITE claim - which is exactly the state main.py is in at N=1 - and
|
||||
# they still answer what they answered before the field existed. If a line above
|
||||
# had to be changed to accommodate `actuator`, stage 2 would not be the shipped
|
||||
# arbiter and the refactor would not be pure.
|
||||
|
||||
print()
|
||||
print("ARB-03 1. the field, and what its absence means")
|
||||
|
||||
lone = Claim.set("loop", P_LOOP, 900)
|
||||
check("a claim built without naming an actuator carries one anyway",
|
||||
lone.actuator == ACTUATOR_SITE)
|
||||
# ⚠️ THE TYPE ITSELF, NOT ONLY THE TWO HELPERS. Measured: with only the helper
|
||||
# checked, emptying the DATACLASS default survives this suite untouched, because
|
||||
# `Claim.set()` and `Claim.limit()` pass their own default down and the field's
|
||||
# never runs. Anything that builds a `Claim(...)` directly - a future strategy,
|
||||
# a `dataclasses.replace()` - would have got the unspecified actuator that this
|
||||
# card exists to remove.
|
||||
check("...and so does one built through the dataclass directly, which is the "
|
||||
"constructor the two helpers do not cover",
|
||||
Claim("loop", P_LOOP).actuator == ACTUATOR_SITE)
|
||||
check("...and it is an explicit SITE, not None and not an empty string. "
|
||||
"'unspecified' is what the shipped code had, and 'unspecified' is what "
|
||||
"made every claim implicitly about the one and only actuator",
|
||||
isinstance(lone.actuator, str) and lone.actuator != ""
|
||||
and lone.actuator is not None)
|
||||
check("...and `source` is still the first positional argument, which is what "
|
||||
"test_peakguard.py part 10f's AST scan reads off main.py to pin the "
|
||||
"claim-source set. specs.md declares `actuator` first; the tuple position "
|
||||
"is not the part of that declaration that carries meaning, and moving "
|
||||
"`source` off zero would blind the tripwire that guards SAFETY-25",
|
||||
Claim.limit("device", P_SAFETY, -1, 1).source == "device")
|
||||
|
||||
print()
|
||||
print("ARB-03 2. the split: eight sources, each classified where it is BUILT")
|
||||
# The classification is graded against what each claim is ABOUT, restated here
|
||||
# so that the table in arbiter.py and the expectation in a test are not the same
|
||||
# sentence read twice. test_peakguard.py part 10f pins this set against main.py's
|
||||
# own AST, so a ninth source cannot arrive without both files noticing.
|
||||
SITE_SOURCES = {
|
||||
"loop": "regulates grid_w, the P1 measurement - one meter, one site",
|
||||
"peak": "the quarter-hour average offtake AT the grid connection",
|
||||
"arbitrage": "buys and sells at the grid against a day-ahead price",
|
||||
"safety": "'stopped' is the site's switch, 'inputs missing' is the "
|
||||
"site's own meter - neither is about a pack",
|
||||
# SAFETY-31, and it is the entry most easily filed on the wrong side.
|
||||
"circulation": "sum(|Bi|) - |sum(Bi)| is defined OVER THE ROSTER and is "
|
||||
"identically zero for any one unit - there is no fact of "
|
||||
"the matter about which of two opposing inverters is the "
|
||||
"offender, so there is nothing to file it per-unit on",
|
||||
# SAFETY-30, and it is the entry most easily confused with `failsafe`
|
||||
# below, because the same three words describe both.
|
||||
"sign_site": "the SUM of every standing command against the meter. The "
|
||||
"offending number is the SITE target, which no single "
|
||||
"inverter owns - parking one of them would leave the rest "
|
||||
"pushing the same way with the guard satisfied",
|
||||
}
|
||||
UNIT_SOURCES = {
|
||||
"device": "one inverter's own reported min/max rating",
|
||||
"supervised": "max_w caps what may be WRITTEN to one setpoint entity",
|
||||
"failsafe": "per-unit evidence, per-unit remedy: since SAFETY-30 it "
|
||||
"grades THIS unit's command against THIS unit's OWN "
|
||||
"measured power (0x0518), so what it learns is about one "
|
||||
"device. The site-wide half moved to `sign_site`",
|
||||
"maintenance": "the monthly recalibration is a pack procedure",
|
||||
}
|
||||
for _src, _why in sorted(SITE_SOURCES.items()):
|
||||
print(f" site {_src:<11} {_why}")
|
||||
for _src, _why in sorted(UNIT_SOURCES.items()):
|
||||
print(f" unit {_src:<11} {_why}")
|
||||
check("all TEN claim sources are classified, and only those ten",
|
||||
set(CLAIM_SCOPE) == set(SITE_SOURCES) | set(UNIT_SOURCES))
|
||||
check("the six that are about the GRID CONNECTION are site claims",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE} == set(SITE_SOURCES))
|
||||
check("the four that are about a PACK, a DEVICE or one write are per-inverter",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT} == set(UNIT_SOURCES))
|
||||
check("a source nobody classified cannot be routed at all - actuator_for() "
|
||||
"raises rather than defaulting to the site, because defaulting to the "
|
||||
"site is the failure this card removes",
|
||||
_raises(lambda: actuator_for("reserve", "inverter-a", ("inverter-a",))))
|
||||
|
||||
print()
|
||||
print("ARB-03 3. at N=1 the site IS the unit, so nothing moves")
|
||||
# §6.2's identity: with one inverter the fabricated grid reading and the battery
|
||||
# setpoint are the same number, so there is one actuator and it is both.
|
||||
ONE = ("inverter-a",)
|
||||
TWO = ("inverter-a", "inverter-b")
|
||||
check("with one inverter every source routes to the site, per-inverter ones "
|
||||
"included - that is the identity, not the classification being ignored",
|
||||
all(actuator_for(s, "inverter-a", ONE) == ACTUATOR_SITE for s in CLAIM_SCOPE))
|
||||
check("...and with none configured at all, likewise",
|
||||
all(actuator_for(s, "inverter-a", ()) == ACTUATOR_SITE for s in CLAIM_SCOPE))
|
||||
check("with TWO the identity breaks and the split becomes real: the four "
|
||||
"per-inverter sources route to the unit this controller drives, the six "
|
||||
"site sources stay on the grid connection",
|
||||
{s: actuator_for(s, "inverter-a", TWO) for s in CLAIM_SCOPE}
|
||||
== {**{s: "inverter-a" for s in UNIT_SOURCES},
|
||||
**{s: ACTUATOR_SITE for s in SITE_SOURCES}})
|
||||
|
||||
print()
|
||||
print("ARB-03 4. stage 2 IS the shipped arbiter (AC 3)")
|
||||
# ⚠️ NOT ASSERTED, REPLAYED. Every claim list this file resolves above is run
|
||||
# through BOTH entry points and every field the shipped code reads off a
|
||||
# Resolution is compared. `resolve()` at N=1 is `site_resolve()` on the same
|
||||
# list, so a single edit inside stage 2 would show up in every check above as
|
||||
# well as here - and one that only affects the wrapper shows up only here.
|
||||
REPLAY = [
|
||||
[],
|
||||
[Claim.set("loop", P_LOOP, 900)],
|
||||
[Claim.set("loop", P_LOOP, 900), Claim.set("maintenance", P_MAINTENANCE, 2500)],
|
||||
[Claim.set("loop", P_LOOP, 4000),
|
||||
Claim.limit("supervised", P_SAFETY, lo=-2000, hi=2000, reason="max_w")],
|
||||
[Claim.set("loop", P_LOOP, 4000), Claim.limit("a", P_SAFETY, hi=3000),
|
||||
Claim.limit("b", P_SAFETY, hi=1500)],
|
||||
[Claim.set("loop", P_LOOP, 900), charge_only],
|
||||
[Claim.set("loop", P_LOOP, 900), charge_only, Claim.set("peak", P_PEAK, 2500)],
|
||||
[Claim.set("peak", P_PEAK, 9000), charge_only,
|
||||
Claim.limit("device", P_SAFETY, lo=-5000, hi=5000, reason="rating")],
|
||||
[Claim.set("loop", P_LOOP, 900), Claim.set("safety", P_SAFETY, 0, "inputs missing")],
|
||||
[Claim.set("loop", P_LOOP, 500), Claim.limit("x", P_SAFETY, lo=1000),
|
||||
Claim.limit("y", P_SAFETY, hi=200)],
|
||||
[Claim.set("loop", P_LOOP, -3000),
|
||||
Claim.limit("supervised", P_SAFETY, lo=-1000, hi=1000)],
|
||||
[Claim.set("loop", P_LOOP, -200), charge_only],
|
||||
[Claim.set("arbitrage", P_ARBITRAGE, -2000, "buy"),
|
||||
Claim.limit("peak", P_PEAK, lo=800.0, reason="quarter peak"),
|
||||
Claim.limit("supervised", P_SAFETY, lo=-2000, hi=2000, reason="max_w")],
|
||||
]
|
||||
|
||||
|
||||
def _shape(r):
|
||||
return (r.target_w, r.winner, r.bound_by, r.contradiction,
|
||||
list(r.considered), r.explain())
|
||||
|
||||
|
||||
_diff = [i for i, cl in enumerate(REPLAY)
|
||||
if _shape(resolve(cl)) != _shape(site_resolve(cl))]
|
||||
print(f" replayed {len(REPLAY)} claim lists through both entry points")
|
||||
check("NOT ONE of them resolves differently - target, winner, binder, "
|
||||
"contradiction flag, the considered list and the operator line are equal "
|
||||
"on every one. At N=1 the three stages are the shipped arbiter with "
|
||||
"bookkeeping either side of it", _diff == [] and len(REPLAY) >= 12)
|
||||
check("...and stage 3 hands the whole target to the one actuator there is, "
|
||||
"which is the N=1 identity rather than an allocation",
|
||||
resolve([Claim.set("loop", P_LOOP, 900)]).shares == {ACTUATOR_SITE: 900.0})
|
||||
check("...and says it allocated, because at N<=1 there is nothing to divide",
|
||||
resolve([Claim.set("loop", P_LOOP, 900)]).allocated)
|
||||
|
||||
print()
|
||||
print("ARB-03 5. THE CONTRADICTION THAT CANNOT BE WRITTEN DOWN (AC 4)")
|
||||
# SAFETY-25 §0a, constructed. A per-inverter reserve says "this pack must not
|
||||
# discharge" (`hi = 0`); the peak guard says "the site must deliver at least
|
||||
# 1500 W" (`lo = 1500`). At N=1 those are two bounds on ONE number and they
|
||||
# genuinely cross - which is today's behaviour, and today's hazard, and is left
|
||||
# exactly as it is. Filed on TWO actuators they are bounds on two different
|
||||
# numbers, and there is no expression in which one is the other's counterpart.
|
||||
SITE_SIDE = [Claim.set("loop", P_LOOP, -1500.0, "grid"),
|
||||
Claim.limit("peak", P_PEAK, lo=1500.0, reason="quarter peak")]
|
||||
CROSSED = SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0,
|
||||
reason="charge-only")]
|
||||
SPLIT = SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0,
|
||||
reason="charge-only", actuator="inverter-b")]
|
||||
r_crossed, r_split = resolve(CROSSED), resolve(SPLIT)
|
||||
print(f" both on one actuator: {r_crossed.explain()}")
|
||||
print(f" the `hi` on inverter-b: {r_split.explain()} "
|
||||
f"inverter-b bounds {r_split.unit_bounds['inverter-b'].explain()}")
|
||||
check("filed on ONE actuator the pair still contradicts and still parks the "
|
||||
"battery at 0 W in the billed quarter. That is the shipped behaviour and "
|
||||
"this card does not change it - at N=1 the two really are bounds on one "
|
||||
"number", r_crossed.contradiction and r_crossed.target_w == 0.0)
|
||||
check("filed on TWO the site keeps its floor: the unit `hi` is not a term of "
|
||||
"the site's `lo > hi` test, so there is no contradiction to flag",
|
||||
not r_split.contradiction and r_split.target_w == 1500.0)
|
||||
check("...and the constraint is not lost, it is CARRIED - inverter-b's own "
|
||||
"interval still says 'do not discharge', for the allocator to honour when "
|
||||
"it divides the 1500 W", r_split.unit_bounds["inverter-b"].hi == 0.0
|
||||
and r_split.unit_bounds["inverter-b"].hi_src == "maintenance")
|
||||
check("...and the site target is bit-for-bit what the site claims alone "
|
||||
"resolve to, so the unit claim contributed NOTHING to it - which is the "
|
||||
"'cannot be expressed' rather than 'is guarded against'",
|
||||
_shape(site_resolve(SITE_SIDE))[:4] == _shape(r_split)[:4])
|
||||
|
||||
# Swept rather than argued: no per-inverter source, at any bound, on any unit,
|
||||
# can reach the site's limits.
|
||||
_SWEEP_N = _SWEEP_BAD = 0
|
||||
for _src in sorted(UNIT_SOURCES):
|
||||
for _unit in ("inverter-a", "inverter-b"):
|
||||
for _lo, _hi in ((0.0, inf), (-inf, 0.0), (2500.0, inf), (-inf, -2500.0),
|
||||
(900.0, 100.0)):
|
||||
_r = resolve(SITE_SIDE + [Claim.limit(_src, P_MAINT_SHAPE, lo=_lo,
|
||||
hi=_hi, actuator=_unit)])
|
||||
_SWEEP_N += 1
|
||||
if _r.contradiction or _r.target_w != 1500.0:
|
||||
_SWEEP_BAD += 1
|
||||
print(f" swept {_SWEEP_N} (per-inverter source x unit x bound) filings "
|
||||
f"against a live site floor: {_SWEEP_BAD} disturbed the site target")
|
||||
check(f"NOT ONE of the {_SWEEP_N} filings contradicts the site floor or moves "
|
||||
f"the site target - including the last bound of each row, which is a unit "
|
||||
f"contradicting ITSELF (lo 900 > hi 100). A unit's own impossible pair "
|
||||
f"parks that unit; it does not park the site",
|
||||
_SWEEP_BAD == 0 and _SWEEP_N >= 40)
|
||||
_self_bad = resolve(SITE_SIDE + [Claim.limit("maintenance", P_MAINT_SHAPE,
|
||||
lo=900.0, hi=100.0,
|
||||
actuator="inverter-b")])
|
||||
check("...and that unit says so on its own bounds, so the fault is reported "
|
||||
"where it was made rather than swallowed",
|
||||
_self_bad.unit_bounds["inverter-b"].contradiction
|
||||
and "CONTRADICTION" in _self_bad.unit_bounds["inverter-b"].explain())
|
||||
|
||||
print()
|
||||
print("ARB-03 6. stage 1: one unit's claims, one unit's interval")
|
||||
mb = pre_resolve([Claim.limit("device", P_SAFETY, -5000, 5000, "rating"),
|
||||
Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w"),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only")])
|
||||
print(f" a unit filing rating, max_w and charge-only: {mb.explain()}")
|
||||
check("the most restrictive of the unit's own limits is the interval",
|
||||
mb.lo == -2000 and mb.hi == 0.0 and mb.hi_src == "maintenance"
|
||||
and mb.lo_src == "supervised")
|
||||
owned = pre_resolve([Claim.set("maintenance", P_MAINTENANCE, -2500, "charge"),
|
||||
Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w"),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only")])
|
||||
print(f" a unit whose maintenance owns the setpoint: {owned.explain()}")
|
||||
check("a unit's own winning SET gates its own limits exactly as clause 2 does "
|
||||
"at the site - the P_MAINT_SHAPE ceiling is not applied to a "
|
||||
"P_MAINTENANCE drain that outranks it", owned.hi == 2000.0)
|
||||
check("...and the SET's value travels BESIDE the interval, not inside it. "
|
||||
"Folding -2500 into [-2500, -2500] would turn 'clamped to max_w' into "
|
||||
"'contradicts max_w', which is a different answer and a wrong one",
|
||||
owned.pinned_w == -2500 and owned.pinned_by == "maintenance"
|
||||
and owned.gate == P_MAINTENANCE and not owned.contradiction)
|
||||
|
||||
print()
|
||||
print("ARB-03 7 / ALLOC-01: the seam, and what now occupies it")
|
||||
# ⚠️ THIS PART WAS "the seam is a seam, and NOT an allocator" AND IT GRADED THE
|
||||
# DECLINE. ALLOC-01 filled the seam, so the decline at N>=2 is gone - and the
|
||||
# checks that graded it are RE-AIMED rather than deleted, because the two halves
|
||||
# they were really about are both still true and both still worth a line: the
|
||||
# N<=1 pass-through is byte-identical, and the seam still does not BROADCAST.
|
||||
check("with no units the whole target goes to the site actuator",
|
||||
allocate(1500.0, {}) == ({ACTUATOR_SITE: 1500.0}, True))
|
||||
check("with one unit the share IS the site target - §6.2's N=1 identity, "
|
||||
"pass-through. ⚠️ A FLOAT, UNROUNDED AND UNCLAMPED: this is the "
|
||||
"compatibility promise every N=1 replay in this repository depends on, "
|
||||
"and the general path below does neither of those things",
|
||||
allocate(1500.0, {"inverter-a": UnitBounds()})
|
||||
== ({"inverter-a": 1500.0}, True))
|
||||
check("...and it is byte-identical on a fractional target too, which is where a "
|
||||
"'tidy this into the general path' refactor would show up: the general "
|
||||
"path rounds to the 1 W register, the pass-through must not",
|
||||
allocate(1500.4, {"inverter-a": UnitBounds()})
|
||||
== ({"inverter-a": 1500.4}, True))
|
||||
_shares, _ok = allocate(1500.0, {"inverter-a": UnitBounds(),
|
||||
"inverter-b": UnitBounds()})
|
||||
print(f" two units, ALLOC-01: shares={_shares} allocated={_ok}")
|
||||
check("⚠️ AND THE ONE THING THE SEAM MUST NEVER DO, WHICH IS THE WHOLE OF "
|
||||
"ARCH-01: it does not BROADCAST. Hand the site target to each inverter "
|
||||
"and each supplies it IN FULL - the gain at the meter becomes N times the "
|
||||
"per-unit gain, which admin/goodwe's two-master rig measures as a 4000 W "
|
||||
"peak-to-peak limit cycle at gain 1.0 with not one guard firing. This "
|
||||
"line went red on ARB-03's decline and it goes red on a broadcast, which "
|
||||
"is the point: it grades the OUTPUT, not the mechanism",
|
||||
1500.0 not in _shares.values())
|
||||
check("...it allocates instead, and the shares SUM to the site target exactly. "
|
||||
"That is the safety property: sum(s_i) = S is what makes the gain at the "
|
||||
"meter a convex combination of the per-unit gains for ANY split, so the "
|
||||
"weights are a comfort choice and a bad split cannot destabilise the site",
|
||||
_ok is True and sum(_shares.values()) == 1500
|
||||
and sorted(_shares) == ["inverter-a", "inverter-b"])
|
||||
check("...and an odd target still sums exactly, which is the half a per-unit "
|
||||
"round() gets wrong: 1501/2 is 750.5 twice, and two roundings of that are "
|
||||
"either 1500 or 1502. Largest remainder gives 751 and 750",
|
||||
sum(allocate(1501.0, {"inverter-a": UnitBounds(),
|
||||
"inverter-b": UnitBounds()})[0].values()) == 1501)
|
||||
check("⚠️ AND THE DECLINE IS NOT GONE, IT IS RE-AIMED. It is still correct when "
|
||||
"no safe split exists at all, and PR #40's reviewer proved that branch was "
|
||||
"unreachable and untested once already - removing its trigger without "
|
||||
"giving it a new one would rebuild that hole. Here: every inverter's "
|
||||
"master stale, so there is no envelope set to allocate into",
|
||||
allocate(1500.0, {"inverter-a": UnitBounds(),
|
||||
"inverter-b": UnitBounds()}, live=()) == ({}, False))
|
||||
|
||||
# ⚠️ AND `resolve()` HAS TO HONOUR THE ROSTER IT IS GIVEN, WHICH IS NOT THE SAME
|
||||
# THING AS HAVING A `units` PARAMETER. Left None the roster is DERIVED from the
|
||||
# claims, and that derivation is right only for a caller that files a claim for
|
||||
# every unit every cycle. Ignore the argument and derive it always - `if units
|
||||
# is None:` -> `if True:` - and a unit that filed nothing this cycle simply
|
||||
# CEASES TO EXIST: the site of two looks like a site of one, the seam passes the
|
||||
# whole grid target through to the single inverter that spoke, and ARCH-01's
|
||||
# fault is built with the evidence for it removed. That mutation left this whole
|
||||
# suite green until this check was written (PR #40 review), so it is graded on
|
||||
# the one observation that distinguishes the two - a SILENT unit.
|
||||
_silent = resolve([Claim.set("loop", P_LOOP, 900.0),
|
||||
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
|
||||
actuator="inverter-a")],
|
||||
units=TWO)
|
||||
print(f" roster of two, only inverter-a files: bounds="
|
||||
f"{sorted(_silent.unit_bounds)} allocated={_silent.allocated} "
|
||||
f"shares={_silent.shares}")
|
||||
check("resolve() HONOURS the roster it is handed rather than inferring one from "
|
||||
"who happened to speak. inverter-b filed nothing this cycle and is still "
|
||||
"a unit: it gets its own interval, and the site is still a site of TWO, "
|
||||
"so the target is SPLIT across two inverters",
|
||||
sorted(_silent.unit_bounds) == ["inverter-a", "inverter-b"]
|
||||
and _silent.shares == {"inverter-a": 450, "inverter-b": 450})
|
||||
check("...and that is the whole cost of ignoring the argument, stated as the "
|
||||
"number it would produce: derive the roster from the claims instead and "
|
||||
"the site is a site of ONE, so the seam passes ALL 900 W through to "
|
||||
"inverter-a - the silent inverter's absence read as a smaller site, and "
|
||||
"inverter-a told to do the whole site's work on its own. ⚠️ ALLOC-01 "
|
||||
"makes this mutation WORSE, not better: before, both answers refused, so "
|
||||
"only the roster listing distinguished them; now the wrong one produces a "
|
||||
"plausible number that is twice what inverter-a should be given",
|
||||
resolve([Claim.set("loop", P_LOOP, 900.0),
|
||||
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
|
||||
actuator="inverter-a")]).shares
|
||||
== {"inverter-a": 900.0})
|
||||
check("...and left None the roster IS derived from the claims, which is the "
|
||||
"documented default every N=1 replay above depends on - so the parameter "
|
||||
"changes the answer only where the two disagree",
|
||||
resolve([Claim.set("loop", P_LOOP, 900.0),
|
||||
Claim.limit("device", P_SAFETY, -2000, 2000, "rating",
|
||||
actuator="inverter-a")], units=None).allocated is True)
|
||||
|
||||
print()
|
||||
print("ARB-03 8. verified by breaking it: a claim routed to the wrong stage (AC 6)")
|
||||
# The `peak` floor, misfiled on a unit. It is the site's floor - if it lands on
|
||||
# one inverter's interval the SITE keeps no floor at all, and the loop is free to
|
||||
# go on charging through the quarter that sets the month's bill.
|
||||
mis_peak = SITE_SIDE[:1] + [Claim.limit("peak", P_PEAK, lo=1500.0,
|
||||
reason="quarter peak",
|
||||
actuator="inverter-b")]
|
||||
r_mis = resolve(mis_peak)
|
||||
print(f" peak floor misfiled on inverter-b: {r_mis.explain()} "
|
||||
f"scope_errors={r_mis.scope_errors}")
|
||||
check("the mis-routing is CAUGHT: scope_violations names the source and the "
|
||||
"actuator it does not belong on", len(r_mis.scope_errors) == 1
|
||||
and "peak" in r_mis.scope_errors[0])
|
||||
check("...and the reason it must be caught, measured rather than argued: with "
|
||||
"the floor on a unit the SITE has no floor, so the loop charges 1500 W "
|
||||
"into the quarter the guard was trying to shave",
|
||||
r_mis.target_w == -1500.0 and resolve(SITE_SIDE).target_w == 1500.0)
|
||||
check("a UNIT source filed on the site at a site that HAS named units is "
|
||||
"caught too - that is the direction that produces `lo > hi`",
|
||||
scope_violations(SITE_SIDE + [
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0),
|
||||
Claim.limit("device", P_SAFETY, -1, 1, actuator="inverter-b")]) != [])
|
||||
check("...and at N=1, where every source legitimately routes to the site, the "
|
||||
"same list is clean. The check grades ROUTING, not tidiness",
|
||||
scope_violations(SITE_SIDE + [
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0)]) == [])
|
||||
check("an unclassified ninth source is a violation wherever it is filed",
|
||||
scope_violations([Claim.limit("reserve", P_LOOP, hi=0.0)]) != [])
|
||||
check("and the eight, routed by actuator_for() at a two-inverter site, are "
|
||||
"clean - which is what says the router and the checker agree",
|
||||
scope_violations(
|
||||
[Claim.limit(s, P_SAFETY, -1, 1,
|
||||
actuator=actuator_for(s, "inverter-a", TWO))
|
||||
for s in CLAIM_SCOPE]) == [])
|
||||
|
||||
# --- ALLOC-01: AND NOW SOMETHING HAPPENS ABOUT IT ---------------------------
|
||||
# ⚠️ ARB-03 LEFT THIS DELIBERATELY INERT - `scope_violations()` logged and did
|
||||
# not change the resolution, and nothing graded the consequence. ALLOC-01 had to
|
||||
# decide, and decided the allocator CONSUMES it as a REFUSAL rather than as an
|
||||
# input. The reasoning is at `allocator.plan()`'s REFUSAL 1 and the short form
|
||||
# is: the mis-routed claim has already been partitioned by the time stage 3
|
||||
# runs, so its effect is baked into S or into somebody's interval; "consuming"
|
||||
# it as an allocation input would mean RE-ROUTING it, which needs a guess about
|
||||
# which inverter it belonged to that nothing here can make. What is left is that
|
||||
# S itself may be wrong, and dividing a number that may be wrong is worse than
|
||||
# not dividing it.
|
||||
print(f" and stage 3's answer to it: {r_mis.allocation.explain()}")
|
||||
check("⚠️ the mis-routing is no longer only a log line: stage 3 REFUSES to "
|
||||
"allocate on a claim list it has been told is mis-routed, so main.py "
|
||||
"fails toward inaction and shouts instead of dividing a number that may "
|
||||
"be wrong. That is the same answer clause 3 already gives a contradiction",
|
||||
r_mis.allocated is False and r_mis.shares == {}
|
||||
and "mis-routed" in r_mis.allocation.refused)
|
||||
check("...and it is NOT consumed as an ENVELOPE, which is the tempting reading "
|
||||
"and the wrong one: a unit-scoped claim that landed on the site names no "
|
||||
"unit, so promoting it means either guessing one or applying one "
|
||||
"inverter's rating to a sibling that does not have it. Nothing here is "
|
||||
"promoted - the refusal carries no shares at all",
|
||||
r_mis.allocation.plans == () and r_mis.allocation.dropped == ())
|
||||
check("...and a correctly routed cycle is unaffected, which is what says this "
|
||||
"grades ROUTING and not the presence of units: the same site claims with "
|
||||
"the floor where it belongs allocate normally",
|
||||
resolve(SITE_SIDE, units=TWO).allocated is True)
|
||||
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
|
||||
@@ -4,8 +4,8 @@
|
||||
|
||||
No framework, asserts only, same house style as test_freeze.py.
|
||||
|
||||
Six parts, and parts 3 and 4 are the ones that carry SAFETY-03's own
|
||||
acceptance criteria; part 6 is TEST-11's:
|
||||
Seven parts, and parts 3 and 4 are the ones that carry SAFETY-03's own
|
||||
acceptance criteria; part 6 is TEST-11's and part 7 is SAFETY-28's:
|
||||
|
||||
1. THE CLAMP ARITHMETIC, on the shipped `clamp_to_rating()` - boundaries,
|
||||
symmetry, the device second stage, and the non-finite cases. Table driven.
|
||||
@@ -31,6 +31,13 @@ acceptance criteria; part 6 is TEST-11's:
|
||||
watchdog could see when it was consulted - so that a rename or a helper
|
||||
does not trip it, and with the write-path half exercised on a stimulus of
|
||||
its own, because parts 3-5 never produce one through cycle().
|
||||
7. SAFETY-28. THE WRITE PATH IS GATED ON THE ALLOCATION RECORD - a value the
|
||||
single allocator did not place on THIS tick does not reach the wire, a
|
||||
record from a previous tick cannot authorise one, and 0 W is authorised
|
||||
unconditionally so the failsafe can never deadlock behind the gate. This is
|
||||
the check that replaced a config-shape proxy: `ACTUATOR_WRITE_KEYS` graded
|
||||
how many option KEYS exist, which stays 1 while a per-inverter config adds
|
||||
a second real writer.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY PART 4 ALSO ASSERTS ON `Decision`'s BOOLEANS AND NOT ON `reason`
|
||||
@@ -65,6 +72,7 @@ Read MUTATION.md before you report a survivor.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import io
|
||||
import math
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
@@ -73,7 +81,10 @@ from app.clamp import (
|
||||
CLEAR_CYCLES, REASON_CODE, REASSERT_S, ClampWatchdog, clamp_to_rating,
|
||||
is_commandable,
|
||||
)
|
||||
from app.allocator import Allocation, UnitPlan, plan
|
||||
from app.arbiter import P_LOOP, Claim, UnitBounds, allocate, resolve
|
||||
from app.control import Tuning, compute
|
||||
from app.inverter import Inverter
|
||||
from app.main import Controller
|
||||
|
||||
fails = []
|
||||
@@ -531,16 +542,48 @@ print()
|
||||
print("5. no path reaches the wire around the clamp")
|
||||
|
||||
|
||||
def arm(c, value):
|
||||
"""Give `c` a real allocation record authorising `value` on the CURRENT tick.
|
||||
|
||||
⚠️ SAFETY-28 MADE THIS NECESSARY, AND THE FACT THAT IT IS NECESSARY IS THE
|
||||
TICKET. `write_setpoint()` now refuses any value the single allocator did
|
||||
not place on this tick, so the probes below - which call it directly, the
|
||||
way the heartbeat and the operator's buttons do - have to say where their
|
||||
number came from. Before this they did not, and that was precisely the hole:
|
||||
a second writer's number reached the wire on nothing but the fact that
|
||||
somebody called the method.
|
||||
|
||||
⚠️ AND IT IS BUILT THROUGH THE SHIPPED `resolve()`, NOT BY HAND. A helper
|
||||
that assembled an `Allocation` itself would be a second allocator living in
|
||||
the test file, and every check below would then be grading the fixture's
|
||||
idea of a record rather than the one main.py produces. The tick is bumped
|
||||
the same way `cycle()` bumps it, for the same reason.
|
||||
"""
|
||||
c.alloc_tick += 1
|
||||
res = resolve([Claim.set("loop", P_LOOP, value, "test stimulus")],
|
||||
units=c.units, live=c.units, tick=c.alloc_tick)
|
||||
c.allocation = res.allocation
|
||||
return res.allocation
|
||||
|
||||
|
||||
async def _direct():
|
||||
hass = _Hass(0.0)
|
||||
c = Controller({"setpoint_entity": "number.sp", "max_w": 2000,
|
||||
"meter_source": "off"},
|
||||
hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
# The shape the heartbeat, shutdown() and handle_action() all use.
|
||||
await c.write_setpoint(9999.0, force=True)
|
||||
await c.write_setpoint(-9999.0, force=True)
|
||||
# The shape the heartbeat, shutdown() and handle_action() all use - each one
|
||||
# authorised by this tick's allocation, which is what those callers have
|
||||
# too: the heartbeat re-affirms `self.target`, and the buttons write 0 W,
|
||||
# which needs no allocator at all (see part 7).
|
||||
for wanted in (9999.0, -9999.0):
|
||||
arm(c, wanted)
|
||||
await c.write_setpoint(wanted, force=True)
|
||||
# A nan is loss of input, not an unauthorised write: rule 1 turns it into
|
||||
# 0 W ABOVE the gate, and 0 W is always authorised. No arming, on purpose -
|
||||
# if the gate ever moved above the coercion this line would go red.
|
||||
await c.write_setpoint(float("nan"), force=True)
|
||||
arm(c, 1500.0)
|
||||
await c.write_setpoint(1500.0, force=True)
|
||||
return hass, c
|
||||
|
||||
@@ -558,6 +601,56 @@ check("an in-range value is untouched", hass_d.writes[3] == 1500.0)
|
||||
check("every emitted frame satisfies |emitted| <= the rating",
|
||||
all(abs(w) <= 2000.0 for w in hass_d.writes))
|
||||
|
||||
# --- 5b. ALLOC-01: AND THE ALLOCATOR DID NOT ADD ONE ------------------------
|
||||
# ⚠️ "NO PATH REACHES THE WIRE AROUND THE CLAMP" IS A CLAIM ABOUT THE WHOLE
|
||||
# ADD-ON, so it has to be re-made every time a module learns to produce a number
|
||||
# that looks like a setpoint. ALLOC-01 added `app/allocator.py`, whose output is
|
||||
# a dict of per-inverter watts - numbers that are exactly the shape of a thing
|
||||
# somebody would write - and the temptation it creates is real: a second writer
|
||||
# for a second inverter is DEV-02's card, and the wrong way to build it is a
|
||||
# `set_number` call next to the allocation.
|
||||
#
|
||||
# Two checks, and neither is about the allocator's arithmetic:
|
||||
# * it CANNOT write, and that is established from its imports rather than
|
||||
# from its behaviour, because a behavioural check only sees the paths a
|
||||
# fixture happens to take;
|
||||
# * at the shipped roster the number that reaches the wire is still the
|
||||
# arbiter's `target_w`, unclamped by the allocator, so SAFETY-03's clamp is
|
||||
# still the binding one and not a second opinion after a first clamp.
|
||||
import app.allocator as _alloc_mod # noqa: E402
|
||||
|
||||
_alloc_src = io.open(_alloc_mod.__file__, encoding="utf-8").read()
|
||||
_alloc_imports = sorted(
|
||||
n.split(".")[0]
|
||||
for line in _alloc_src.splitlines() if line.startswith(("import ", "from "))
|
||||
for n in [line.split()[1]])
|
||||
print(f" app/allocator.py imports: {_alloc_imports}")
|
||||
check("the allocator imports NOTHING that can reach the wire - no `hass`, no "
|
||||
"`aiohttp`, not even `main`. It is a pure function of intervals and a "
|
||||
"number, so 'it cannot write' is a property of the file rather than of "
|
||||
"the paths a fixture happened to take",
|
||||
_alloc_imports == ["dataclasses", "math"])
|
||||
check("...and it never mentions the setpoint entity, `set_number`, or the "
|
||||
"clamp - the three names any bypass would have to spell",
|
||||
not any(n in _alloc_src for n in ("set_number", "setpoint_entity",
|
||||
"clamp_to_rating")))
|
||||
check("...and it must not: it has no measurement either. The allocator reading "
|
||||
"P1 would be a SECOND integrator on the site measurement, which is the "
|
||||
"same two-writers failure one level up",
|
||||
not any(n in _alloc_src for n in ("p1", "P1Ingest", "grid_w")))
|
||||
|
||||
check("at the shipped roster of ONE the allocator is a pass-through, so the "
|
||||
"number handed to write_setpoint() is the arbiter's own target and "
|
||||
"SAFETY-03's clamp is still the FIRST and only clamp it meets. An "
|
||||
"allocator that pre-clamped here would leave this file grading a value "
|
||||
"that was already in range, and the clamp untested on the live path",
|
||||
allocate(9999.0, {"inverter-a": UnitBounds()}) == ({"inverter-a": 9999.0},
|
||||
True))
|
||||
check("...and that unclamped 9999 W is exactly what part 5 above just proved "
|
||||
"the write path stops at the rating. The two halves meet here: the "
|
||||
"allocator does not clamp, the wire does",
|
||||
hass_d.writes[0] == 2000.0)
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("6. TEST-11: the guard's evidence is THIS cycle's write, not the last one")
|
||||
@@ -690,13 +783,21 @@ class _RefactoredController(Controller):
|
||||
Neither changes when the guard runs relative to the write, so every check in
|
||||
`evidence_checks()` must stay green. If one of them goes red here, the check
|
||||
is grading the text of main.py and has to be thrown away.
|
||||
|
||||
⚠️ THE SIGNATURE GAINED `unit=` IN DEV-02 AND THIS FIXTURE FOLLOWED IT, which
|
||||
is the honest update and not a weakening: `write_setpoint()` now addresses ONE
|
||||
inverter (or, with `unit=None`, commands the whole site to 0 W), because a
|
||||
controller with a roster cannot have one write path that means "the
|
||||
inverter". A delegate that dropped the argument would silently re-broadcast
|
||||
at N>=2, so it is passed through here exactly as a real refactor would have
|
||||
to pass it through.
|
||||
"""
|
||||
|
||||
async def _emit_setpoint(self, value, *, force=False):
|
||||
await Controller.write_setpoint(self, value, force=force)
|
||||
async def _emit_setpoint(self, value, *, force=False, unit=None):
|
||||
await Controller.write_setpoint(self, value, force=force, unit=unit)
|
||||
|
||||
async def write_setpoint(self, value, *, force=False):
|
||||
await self._emit_setpoint(value, force=force)
|
||||
async def write_setpoint(self, value, *, force=False, unit=None):
|
||||
await self._emit_setpoint(value, force=force, unit=unit)
|
||||
|
||||
async def _clamp_guard(self):
|
||||
await Controller.check_output_clamp(self)
|
||||
@@ -747,6 +848,11 @@ async def _write_path(moved=False):
|
||||
# The inverter is SMALLER than the configured ceiling - SAFETY-20's install.
|
||||
c.dev_min, c.dev_max = -2500.0, 2500.0
|
||||
c.target = 3000.0
|
||||
# SAFETY-28: the write path only carries numbers the allocator placed, so
|
||||
# this stimulus is authorised the same way cycle()'s is. It has to be: the
|
||||
# clamp is what this part grades, and a gate refusal would substitute 0 W
|
||||
# and there would be no clamp to see.
|
||||
arm(c, c.target)
|
||||
if moved:
|
||||
await c.check_output_clamp()
|
||||
await c.write_setpoint(c.target)
|
||||
@@ -792,6 +898,321 @@ check("...and main.py:856's consumer is the line that goes quietly false",
|
||||
bool(ctl_w.clamp_last and ctl_w.clamp_last.engaged))
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("7. SAFETY-28: the write path is gated on the allocation record")
|
||||
|
||||
# WHY THIS PART IS IN THIS FILE. Part 5 already claims "no path reaches the wire
|
||||
# around the clamp", and the clamp is the last thing between a bug and the
|
||||
# hardware. SAFETY-28 adds a second thing on the same path and asks a different
|
||||
# question of it: not "is this number in range" but "WHO CHOSE THIS NUMBER".
|
||||
#
|
||||
# THE DEFECT IT REPLACES. specs §1.5 makes two writers on one actuator a
|
||||
# non-goal, and until this ticket that was enforced by
|
||||
# `len(validate.ACTUATOR_WRITE_KEYS) == 1` - one option key, so a second writer
|
||||
# is not expressible. True, and a statement about the OPTIONS SCHEMA rather than
|
||||
# about the writes: add CFG-04's per-inverter config and there are two real
|
||||
# writers with that length still 1. test_validate.py part 2 grades the config
|
||||
# half; this part grades the write half, which is the one that does not care
|
||||
# what the options look like.
|
||||
|
||||
A_UNIT, B_HYPO = "inverter-a", "inverter-b"
|
||||
|
||||
|
||||
def fresh(**over):
|
||||
"""A Controller with a stub HA, no cycle run, and therefore NO record."""
|
||||
hass = _Hass(0.0)
|
||||
c = Controller(dict({"setpoint_entity": "number.sp", "max_w": 2000,
|
||||
"meter_source": "off"}, **over),
|
||||
hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
return hass, c
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7a. AC 1 - an unauthorised value is REFUSED AT THE WRITE PATH
|
||||
# --------------------------------------------------------------------------- #
|
||||
# The second writer, modelled as what it would actually look like in code: some
|
||||
# other strategy with arithmetic of its own calling the one method that reaches
|
||||
# the wire. It has a perfectly reasonable number - in range, finite, nothing the
|
||||
# clamp would object to - and the only thing wrong with it is that nothing
|
||||
# allocated it.
|
||||
async def _second_writer():
|
||||
hass, c = fresh()
|
||||
arm(c, 1500.0) # the allocator placed 1500 W this tick
|
||||
await c.write_setpoint(1500.0, force=True) # the loop's own write
|
||||
await c.write_setpoint(1200.0, force=True) # ...and the second writer's
|
||||
return hass, c
|
||||
|
||||
|
||||
hass_2w, ctl_2w = asyncio.run(_second_writer())
|
||||
print(f" allocator placed +1500 W; a second writer asked for +1200 W; "
|
||||
f"the device saw {hass_2w.writes}")
|
||||
check("AC 1: a value the allocation record does not contain never reaches the "
|
||||
"device. 1200 W is in range and finite - the clamp has no opinion about "
|
||||
"it - so the ONLY thing that stopped it is that no allocator placed it",
|
||||
1200.0 not in hass_2w.writes)
|
||||
check("...and it is REFUSED, not merely logged: 0 W goes on the wire in its "
|
||||
"place. Returning instead would leave the inverter latched on the last "
|
||||
"command with the ESP32 heartbeat still being fed - holding an "
|
||||
"unauthorised setpoint quietly, which is the outcome this gate exists "
|
||||
"to prevent",
|
||||
hass_2w.writes == [1500.0, 0.0])
|
||||
check("...and the action log says so in words an operator can act on",
|
||||
any("WRITE REFUSED" in e for e in ctl_2w.events))
|
||||
check("...while the authorised write of the SAME shape went through "
|
||||
"untouched, so the gate is not simply refusing everything",
|
||||
hass_2w.writes[0] == 1500.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7b. AC 2 - a record from a previous tick cannot authorise a write in this one
|
||||
# --------------------------------------------------------------------------- #
|
||||
# ⚠️ THIS IS THE CACHED-ENVELOPE FAULT WEARING A DIFFERENT HAT. allocator.py's
|
||||
# rule is that a unit's interval is read per tick and never cached, because a
|
||||
# pack at its floor or a stale link moves it between one cycle and the next.
|
||||
# A record is that envelope written down - so code that keeps one and replays it
|
||||
# is caching the envelope through the record, and the allocator's own purity
|
||||
# cannot stop it. The tick stamp is what stops it.
|
||||
async def _replay():
|
||||
hass, c = fresh()
|
||||
stale = arm(c, 1500.0) # tick N
|
||||
await c.write_setpoint(1500.0, force=True)
|
||||
arm(c, 800.0) # tick N+1: the envelopes have moved on
|
||||
c.allocation = stale # ...and somebody puts the old one back
|
||||
await c.write_setpoint(1500.0, force=True)
|
||||
return hass, c, stale
|
||||
|
||||
|
||||
hass_rp, ctl_rp, stale_rec = asyncio.run(_replay())
|
||||
print(f" a tick-{stale_rec.tick} record replayed on tick "
|
||||
f"{ctl_rp.alloc_tick}: the device saw {hass_rp.writes}")
|
||||
check("AC 2: replaying the previous tick's record does NOT authorise its "
|
||||
"value again - the write is refused and 0 W goes out instead",
|
||||
hass_rp.writes == [1500.0, 0.0])
|
||||
check("...and the refusal names both ticks, so the reason is legible rather "
|
||||
"than 'computer says no'",
|
||||
"tick" in (ctl_rp.write_refusal(1500.0) or "")
|
||||
and str(stale_rec.tick) in (ctl_rp.write_refusal(1500.0) or "")
|
||||
and str(ctl_rp.alloc_tick) in (ctl_rp.write_refusal(1500.0) or ""))
|
||||
check("...and an UNSTAMPED record - one built by a caller that passed no tick "
|
||||
"at all - is refused too, because 'I cannot say when I was made' must "
|
||||
"fail closed and not read as tick zero",
|
||||
ctl_rp.allocation is not None
|
||||
and (lambda c: (setattr(c, "allocation",
|
||||
plan(1500.0, {A_UNIT: UnitBounds()}))
|
||||
or c.write_refusal(1500.0) is not None))(ctl_rp))
|
||||
|
||||
# ⚠️ AND THE TICK HAS TO ADVANCE ON THE LIVE PATH, WHICH IS A DIFFERENT CLAIM
|
||||
# FROM ANY OF THE ABOVE. Everything so far drives `arm()`, which bumps the
|
||||
# counter itself - so all of it would stay green with `self.alloc_tick += 1`
|
||||
# deleted from cycle(), and the replay protection would be gone on the only path
|
||||
# that matters. This drives REAL cycles and asks the same question of them.
|
||||
async def _live_staleness():
|
||||
hass = _Hass(6000.0)
|
||||
c = Controller({"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": LIVE_MAX_W, "gain": 0.6,
|
||||
"slew_w": 1000, "step_w": 10, "stale_input_s": 15},
|
||||
hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
first, first_v = c.allocation, c.target
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
# ...and now the HOLD: one missed poll, which must NOT age the record, or a
|
||||
# single dropped meter reading would drop the site to 0 W.
|
||||
held_before = c.alloc_tick
|
||||
c.grid = None
|
||||
c.inputs_bad_since = datetime.now(timezone.utc)
|
||||
await c.cycle()
|
||||
hass.writes.clear()
|
||||
await c.write_setpoint(c.target, force=True) # the heartbeat's own call
|
||||
return c, first, first_v, held_before, hass
|
||||
|
||||
|
||||
ctl_ls, rec1, val1, held_before, hass_ls = asyncio.run(_live_staleness())
|
||||
print(f" two real cycles: tick {rec1.tick} -> {ctl_ls.allocation.tick}; "
|
||||
f"a held cycle left it at {ctl_ls.alloc_tick}")
|
||||
check("PRECONDITION: two real cycles produced two records with two different "
|
||||
"ticks and a value worth replaying",
|
||||
rec1.tick != ctl_ls.allocation.tick and val1 != 0.0)
|
||||
check("the tick advances on the LIVE path, so cycle 1's record does not "
|
||||
"authorise a write on cycle 2. Everything above this line drives the "
|
||||
"test's own `arm()` and would stay green with the increment deleted from "
|
||||
"cycle() - this is the check that would not",
|
||||
(lambda c: (setattr(c, "allocation", rec1)
|
||||
or c.write_refusal(val1) is not None))(ctl_ls))
|
||||
check("⚠️ AND A CYCLE THAT PRODUCED NO RESOLUTION DOES NOT AGE IT. The "
|
||||
"'inputs missing, not yet stale' hold returns before the allocator runs, "
|
||||
"precisely so one dropped meter reading does not zero the inverter, and "
|
||||
"the heartbeat re-affirms self.target through this same gate while it "
|
||||
"does. A tick incremented per LOOP ITERATION rather than per RESOLUTION "
|
||||
"would refuse that heartbeat and turn the hold into the outage it exists "
|
||||
"to prevent",
|
||||
ctl_ls.alloc_tick == held_before and hass_ls.writes == [ctl_ls.target]
|
||||
and ctl_ls.target != 0.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7c. THE FAILSAFE CANNOT DEADLOCK BEHIND THE GATE
|
||||
# --------------------------------------------------------------------------- #
|
||||
# ⚠️ THE HAZARD THIS PART EXISTS FOR. `write_setpoint()` is also how layer 2
|
||||
# commands 0 W: cycle()'s two refusal branches substitute a 0 W failsafe and
|
||||
# write it like any other cycle, and shutdown() and the operator's stop button
|
||||
# do the same. Every one of those runs while the allocator has REFUSED - `ok` is
|
||||
# False and there are no shares - so a gate that asked the allocator's
|
||||
# permission to command zero would block the safety write behind the very
|
||||
# component whose failure the safety write answers. A gate that can do that is
|
||||
# worse than the hole it closes.
|
||||
#
|
||||
# The resolution: 0 W is authorised unconditionally, and it is authorised on the
|
||||
# VALUE rather than on a `failsafe=True` flag the caller asserts. The argument is
|
||||
# at Controller.write_refusal(): the hazard §1.5 names is N-times loop gain from
|
||||
# broadcasting one target to N inverters, and at S = 0 the broadcast and the
|
||||
# correct allocation COINCIDE - a_i = 1 for every unit gives every unit 0 W,
|
||||
# which is exactly its share. There is no over-command to make at zero.
|
||||
_hostile = []
|
||||
_h, _c = fresh()
|
||||
_hostile.append(("no record at all", _c))
|
||||
_h, _c = fresh()
|
||||
_c.alloc_tick = 1
|
||||
_c.allocation = plan(1500.0, {A_UNIT: UnitBounds()}, scope_errors=("mis-routed",),
|
||||
tick=1)
|
||||
_hostile.append(("the allocator REFUSED this tick", _c))
|
||||
_h, _c = fresh()
|
||||
_c.allocation = arm(_c, 1500.0)
|
||||
_c.alloc_tick += 7 # ...and then seven ticks went by
|
||||
_hostile.append(("only a stale record", _c))
|
||||
for _why, _c in _hostile:
|
||||
check(f"0 W is authorised with {_why}", _c.write_refusal(0.0) is None)
|
||||
check(f"...and a NON-zero write is still refused with {_why}, so the zero "
|
||||
f"exit is a floor and not an amnesty",
|
||||
_c.write_refusal(1500.0) is not None)
|
||||
|
||||
|
||||
async def _failsafe_wire():
|
||||
"""The refusal path END TO END, through the real cycle().
|
||||
|
||||
⚠️ THE ROSTER HERE IS A HYPOTHESIS AND NOTHING IS MEASURED FROM IT.
|
||||
INVERTER B DOES NOT EXIST. It is named only so `live_units()` can return
|
||||
nothing and drive the allocator into REFUSE_EMPTY, which is the state
|
||||
main.py's first refusal branch is written for and the one this check needs:
|
||||
the allocator itself has failed, and layer 2 must still be able to command
|
||||
zero.
|
||||
"""
|
||||
hass = _Hass(0.0)
|
||||
|
||||
class _Blind(Controller):
|
||||
def live_units(self):
|
||||
return ()
|
||||
|
||||
c = _Blind({"setpoint_entity": "number.sp", "meter_source": "off",
|
||||
"max_w": LIVE_MAX_W, "soc_entity": "sensor.soc",
|
||||
"batt_entity": "sensor.batt", "meter_entity": "sensor.grid"},
|
||||
hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
# ⚠️ DEV-02: THE ROSTER IS GROWN BY ADDING AN `Inverter`, NOT BY ASSIGNING
|
||||
# `units`. `Controller.units` is now DERIVED from `Controller.inverters` and
|
||||
# has no setter, because a settable roster is a site that claims two
|
||||
# actuators while holding one writer - a half-driven site with nothing to
|
||||
# say so. The object carries the writer, which is what makes this fixture a
|
||||
# roster of two rather than a tuple of two names.
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W # while the roster is one
|
||||
_b = Inverter(B_HYPO, setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc", batt_entity="sensor.batt",
|
||||
max_w=LIVE_MAX_W, store=c.store)
|
||||
_b.dev_min, _b.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
_b.soc, _b.batt = 50.0, 0.0
|
||||
c.inverters.append(_b)
|
||||
c.auto = True
|
||||
for _ in range(3):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
return hass, c
|
||||
|
||||
|
||||
hass_fs, ctl_fs = asyncio.run(_failsafe_wire())
|
||||
print(f" allocator refused every tick "
|
||||
f"({ctl_fs.allocation.refused!r}); the device saw {hass_fs.writes}")
|
||||
check("the allocator having failed, the 0 W failsafe still REACHES THE WIRE - "
|
||||
"this is the deadlock the gate must not have, driven through the real "
|
||||
"cycle() and its real refusal branch rather than asserted",
|
||||
not ctl_fs.allocation.ok and hass_fs.writes == [0.0, 0.0]
|
||||
and ctl_fs.target == 0.0)
|
||||
check("...and it was the ALLOCATOR's refusal that produced it, not the gate's "
|
||||
"- if the gate were the thing zeroing this cycle the action log would "
|
||||
"say WRITE REFUSED and the distinction between the two failures would "
|
||||
"be lost to whoever has to debug it",
|
||||
any("ARBITER: REFUSED" in e for e in ctl_fs.events)
|
||||
and not any("WRITE REFUSED" in e for e in ctl_fs.events))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7d. `unmet_w` IS NOT `ok`, AND THE GATE MUST NOT FUSE THEM
|
||||
# --------------------------------------------------------------------------- #
|
||||
# allocator.py says it plainly: an allocation that could not place every watt is
|
||||
# still SAFE TO WRITE and strictly better than commanding zero. Fusing the two
|
||||
# would let ONE SATURATED INVERTER PARK THE WHOLE SITE - the site target goes
|
||||
# unmet by 3800 W, every share is legal, and a gate reading `unmet_w` would
|
||||
# answer that by commanding 0 W and meeting even less of it.
|
||||
_tight = plan(4000.0, {A_UNIT: UnitBounds(lo=-100.0, hi=100.0),
|
||||
B_HYPO: UnitBounds(lo=-100.0, hi=100.0)}, tick=1)
|
||||
_h, _c = fresh()
|
||||
_c.alloc_tick, _c.allocation = 1, _tight
|
||||
print(f" saturated site: {_tight.explain()}")
|
||||
check("PRECONDITION: this record is ok AND has watts it could not place",
|
||||
_tight.ok and _tight.unmet_w == 3800 and _tight.shares[A_UNIT] == 100)
|
||||
check("the gate authorises this unit's share anyway. `unmet_w` is not read - "
|
||||
"it is the site target that went unmet, not a broken allocation",
|
||||
_c.write_refusal(100.0) is None)
|
||||
check("...and it still refuses a value that is not the share, so 'do not read "
|
||||
"unmet_w' has not been implemented as 'read nothing'",
|
||||
_c.write_refusal(4000.0) is not None)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7e. A RECORD THAT CONTRADICTS ITSELF AUTHORISES NOTHING
|
||||
# --------------------------------------------------------------------------- #
|
||||
# `UnitPlan.explain()` renders a share outside its own interval as
|
||||
# "ENVELOPE VIOLATED, DO NOT WRITE". This is the DO NOT WRITE. The shape is the
|
||||
# half-open clamp defect ALLOC-01 fixed: a plan stating the floor and a share
|
||||
# below it in the same breath, and agreeing with itself.
|
||||
#
|
||||
# ⚠️ UNREACHABLE FROM THE ALLOCATOR AS IT STANDS, AND GRADED ANYWAY. At the
|
||||
# shipped roster of one the pass-through's interval is (-inf, +inf) and every
|
||||
# number is inside it. PR #40's reviewer proved what an unreachable ungraded
|
||||
# branch is worth by replacing one with `if False:` and watching the whole suite
|
||||
# stay green, so this one is exercised on a constructed record rather than
|
||||
# trusted.
|
||||
_liar = Allocation(target_w=500.0, sum_w=500, shares={A_UNIT: 500},
|
||||
plans=(UnitPlan(A_UNIT, 500, 2000.0, math.inf, 1.0,
|
||||
"weighted share"),), tick=1)
|
||||
_h, _c = fresh()
|
||||
_c.alloc_tick, _c.allocation = 1, _liar
|
||||
print(f" {_liar.plans[0].explain()}")
|
||||
check("PRECONDITION: the record is `ok`, and its share IS what the gate would "
|
||||
"otherwise match on - so nothing but the envelope question stops it",
|
||||
_liar.ok and _liar.shares[A_UNIT] == 500)
|
||||
check("a share outside its own plan's interval is refused, and the refusal "
|
||||
"quotes the plan's own DO NOT WRITE line",
|
||||
"DO NOT WRITE" in (_c.write_refusal(500.0) or ""))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 7f. AC 5 - AT N=1 NOTHING CHANGES
|
||||
# --------------------------------------------------------------------------- #
|
||||
# The strongest form of this is not a new assertion, it is the 17 other files in
|
||||
# this suite passing unedited on real cycles. What is added here is the
|
||||
# statement that the live path is not being quietly zeroed: over part 3's
|
||||
# sixty-cycle replay - the 10.3 runaway, an inverter that never follows - the
|
||||
# gate refused nothing at all.
|
||||
check("AC 5: across part 3's 60 real cycles the gate refused ZERO writes, so "
|
||||
"the shipped one-inverter path reaches the wire exactly as it did "
|
||||
"before. A gate that silently substituted 0 W here would leave every "
|
||||
"clamp check above green and the install dead",
|
||||
not [e for e in ctl_r.events if "WRITE REFUSED" in e])
|
||||
check("...and the numbers those cycles put on the wire are the arbiter's own "
|
||||
"target, unrounded and unaltered by the record it now has to appear in",
|
||||
hass_r.writes and all(abs(w) <= LIVE_MAX_W for w in hass_r.writes))
|
||||
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
File diff suppressed because it is too large
Load Diff
@@ -114,12 +114,20 @@ from math import inf, isinf
|
||||
from pathlib import Path
|
||||
|
||||
from app import peakguard
|
||||
# ⚠️ THE DROP AND REFUSAL REASONS ARE IMPORTED, NOT TRANSCRIBED. A check that
|
||||
# matched the English would stay green against an allocator that renamed the
|
||||
# case out from under it, which is this repository's own named failure mode.
|
||||
from app.allocator import (
|
||||
DROP_STALE as ALLOC_DROP_STALE, REFUSE_EMPTY as ALLOC_REFUSE_EMPTY,
|
||||
)
|
||||
from app.arbiter import (
|
||||
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY, Claim, resolve,
|
||||
ACTUATOR_SITE, CLAIM_SCOPE, P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK,
|
||||
P_SAFETY, SCOPE_SITE, SCOPE_UNIT, Claim, resolve, scope_violations,
|
||||
)
|
||||
from app.control import Tuning, compute, peak_at_risk
|
||||
from app.freeze import FreezeWatchdogConfig, looks_frozen, rail_w
|
||||
from app import main as app_main
|
||||
from app.inverter import Inverter
|
||||
from app.main import Controller
|
||||
from app.p1 import (
|
||||
PLAUSIBLE_MAX_W, P1Ingest, QUARTER_S, QuarterAverager, make_sample,
|
||||
@@ -170,20 +178,65 @@ def fresh_store(name: str) -> PeakStore:
|
||||
return PeakStore(str(TMP / f"{name}.db"))
|
||||
|
||||
|
||||
def read_option(key: str):
|
||||
"""The shipped default for `key`, out of config.yaml.
|
||||
# ⚠️⚠️ THESE THREE READERS WERE CHANGED BY CFG-04, AND THE OLD ONES WERE THE
|
||||
# PERMISSIVE KIND. Read this before touching them.
|
||||
#
|
||||
# WHAT THEY USED TO DO. `read_option()` walked the whole file and took the FIRST
|
||||
# line whose STRIPPED text started with `<key>:`; `_schema_bound()` did the same
|
||||
# from `schema:` onwards. The docstring justified first-match by naming the one
|
||||
# collision that existed - `peak_cap_w:` appears once under `options:` and once
|
||||
# under `schema:` - and it was right about that one.
|
||||
#
|
||||
# WHY THAT STOPPED BEING SAFE. CFG-04's `inverters:` is a LIST OF OBJECTS, and
|
||||
# its entries carry a `max_w:` of their own, indented six spaces under
|
||||
# `schema:`. `line.strip()` throws the indentation away, so `read_schema_max
|
||||
# ("max_w")` began answering with the PER-INVERTER bound instead of the site
|
||||
# one - silently, and in this file's case correctly, because the two bounds
|
||||
# happen to be the same `int(100,5000)` today. A reader that returns inverter
|
||||
# #1's number and keeps passing is the failure mode this repository is named
|
||||
# after: green, and not watching. config.yaml declares `inverters:` BEFORE
|
||||
# `max_w:` deliberately so that the trap stays baited rather than sorted out by
|
||||
# an ordering nobody would maintain.
|
||||
#
|
||||
# WHAT THEY DO NOW. A top-level option and a top-level schema key are at EXACTLY
|
||||
# two spaces; anything nested is at four or more. So the anchor is the
|
||||
# indentation, the file's two halves disambiguate `peak_cap_w` (the options half
|
||||
# for a default, the schema half for a bound) and first-match is not relied on
|
||||
# at all. And where a key really is ambiguous - the same key twice at top level
|
||||
# in the same half - these RAISE instead of picking one, because a reader that
|
||||
# guesses is how this got here.
|
||||
#
|
||||
# test_inverter.py part 12 runs all of them against a synthetic TWO-INVERTER
|
||||
# config.yaml whose nested numbers differ from its flat ones, which is the only
|
||||
# way to tell a reader that is anchored from one that is lucky.
|
||||
def _cfg_halves():
|
||||
body = (HERE / "config.yaml").read_text(encoding="utf-8")
|
||||
marker = body.index("\nschema:")
|
||||
return body[:marker], body[marker:]
|
||||
|
||||
⚠️ `peak_cap_w:` appears TWICE - once under `options:`, once under `schema:`.
|
||||
test_tariff.py's part 9 documents the trap; this takes the FIRST match, which
|
||||
is the options block, i.e. the number an install actually lands on.
|
||||
"""
|
||||
for line in (HERE / "config.yaml").read_text(encoding="utf-8").splitlines():
|
||||
if line.strip().startswith(f"{key}:"):
|
||||
try:
|
||||
return float(line.split(":", 1)[1].strip())
|
||||
except ValueError:
|
||||
continue
|
||||
return None
|
||||
|
||||
def _top_level(half: str, key: str) -> list:
|
||||
"""Every ` key: ...` line at EXACTLY two spaces. Raises if there are two."""
|
||||
hits = [ln for ln in half.splitlines()
|
||||
if ln.startswith(f" {key}:") and not ln[2:3].isspace()]
|
||||
if len(hits) > 1:
|
||||
raise AssertionError(
|
||||
f"config.yaml declares {key!r} {len(hits)} times at the top level "
|
||||
f"of one block: {hits!r}. This reader will not pick one for you - "
|
||||
"an option with two defaults is a question for whoever wrote the "
|
||||
"second, not a tie for a check to break.")
|
||||
return hits
|
||||
|
||||
|
||||
def read_option(key: str):
|
||||
"""The shipped default for `key`, out of config.yaml's `options:` block."""
|
||||
hits = _top_level(_cfg_halves()[0], key)
|
||||
if not hits:
|
||||
return None
|
||||
try:
|
||||
return float(hits[0].split(":", 1)[1].strip())
|
||||
except ValueError:
|
||||
return None
|
||||
|
||||
|
||||
def read_schema_max(key: str):
|
||||
@@ -202,11 +255,9 @@ def read_schema_min(key: str):
|
||||
|
||||
|
||||
def _schema_bound(key: str, which: int):
|
||||
body = (HERE / "config.yaml").read_text(encoding="utf-8")
|
||||
marker = body.index("\nschema:")
|
||||
for line in body[marker:].splitlines():
|
||||
for line in _top_level(_cfg_halves()[1], key):
|
||||
st = line.strip()
|
||||
if st.startswith(f"{key}:") and "(" in st and ")" in st:
|
||||
if "(" in st and ")" in st:
|
||||
return float(st[st.index("(") + 1:st.rindex(")")].split(",")[which])
|
||||
return None
|
||||
|
||||
@@ -914,6 +965,7 @@ class _Pub:
|
||||
class _Hass:
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
self.per_entity = []
|
||||
self.notifications = []
|
||||
# SAFETY-25. The whole payload, not only the id. AC 3 is about what the
|
||||
# operator READS, so a fixture that records only that a notification
|
||||
@@ -929,6 +981,11 @@ class _Hass:
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(value)
|
||||
# DEV-02. WHICH inverter each write went to, which is the only way to
|
||||
# tell "both units were commanded their own share" from "one unit was
|
||||
# commanded twice". `writes` keeps its old shape - a list of floats -
|
||||
# because a dozen checks above read it that way.
|
||||
self.per_entity.append((entity, value))
|
||||
return True
|
||||
|
||||
async def call(self, domain, service, data):
|
||||
@@ -1282,8 +1339,14 @@ _soc_src = ast.unparse(next(k.value for k in _call.keywords if k.arg == "soc"))
|
||||
print(f" main.py's decide(batt_w=...) is `{_batt_src}`, decide(soc=...) is "
|
||||
f"`{_soc_src}`")
|
||||
check("...and the call site says so in the source: the argument is the measured "
|
||||
"battery attribute, not the standing command and not the resolved target",
|
||||
_batt_src == "self.batt")
|
||||
"battery attribute, not the standing command and not the resolved target. "
|
||||
"⚠️ DEV-02 MOVED WHICH ATTRIBUTE AND NOT WHICH KIND OF THING IT IS: "
|
||||
"`self.batt` was one inverter's power used as a site measurement, and "
|
||||
"`site_batt_w` is the SUM over the roster - still measured, still not "
|
||||
"`standing` and not `self.target`. The reduction itself is graded in "
|
||||
"test_inverter.py; what is pinned here is that a MEASUREMENT is what "
|
||||
"sizes the floor",
|
||||
_batt_src == "self.site_batt_w")
|
||||
# ⚠️ SAFETY-24, AND ON THE SAME SINGLE CALL SITE. This grader takes the FIRST
|
||||
# `.decide(` in main.py and reads a NAME rather than a value, so a second call
|
||||
# site - or a decoy - would defeat it; this card deliberately adds neither, and
|
||||
@@ -1291,8 +1354,14 @@ check("...and the call site says so in the source: the argument is the measured
|
||||
check("...and `soc` is handed over as the MEASURED reading, bare. Not "
|
||||
"`self.soc or 100`, not a `float(..., 100)`, not the maintenance floor: "
|
||||
"a full battery is exactly the value that disarms SAFETY-24's floor, and "
|
||||
"NOTES.md 4.4b records this project shipping that exact defaulting once",
|
||||
_soc_src == "self.soc")
|
||||
"NOTES.md 4.4b records this project shipping that exact defaulting once. "
|
||||
"⚠️ DEV-02 MADE IT `pack_floor_soc` - THE EMPTIEST PACK - and the "
|
||||
"defaulting hazard is unchanged and still the point: that property is a "
|
||||
"bare `min()` over measured readings that answers None if ANY unit did "
|
||||
"not read, because `decide()` treats None as floor-limited, which costs a "
|
||||
"shave rather than a pack. An `or 100` anywhere on that path is the same "
|
||||
"defect with two inverters",
|
||||
_soc_src == "self.pack_floor_soc")
|
||||
check(f"...and main.py has exactly ONE `peakguard.decide(` call site (it has "
|
||||
f"{len(_peak_calls)}), so the call graded above is unambiguously the "
|
||||
f"shipped one. Other modules may call their own decide() - OPT-04's "
|
||||
@@ -1519,6 +1588,14 @@ check("...and its arbiter reason names the SoC floor rather than reusing "
|
||||
# forbidden to cap. Swept rather than argued.
|
||||
SWEEP_NEG = SWEEP_BOTH = SWEEP_N = 0
|
||||
SWEEP_HI = True
|
||||
# ⚠️ ARB-03 ADDS ONE DIMENSION TO THIS PROOF RATHER THAN RE-RUNNING IT UNCHANGED.
|
||||
# `Claim` gained an `actuator`, and the asymmetry that makes this guard safe is
|
||||
# now TWO facts, not one: `hi` is +inf on every claim it files, AND every claim
|
||||
# it files is on the SITE actuator. A `lo` that landed on one inverter's interval
|
||||
# would still have `hi = +inf` and would still never cap a discharge - and would
|
||||
# leave the SITE, the thing the capacity tariff actually bills, with no floor at
|
||||
# all. So the same combinations are swept for both.
|
||||
SWEEP_SITE = True
|
||||
for load in (0.0, CEIL - 500.0, CEIL, CEIL + 300.0, CEIL + 3000.0,
|
||||
LIVE_MAX_W * 3):
|
||||
for elapsed in (30.0, 450.0, 870.0):
|
||||
@@ -1538,6 +1615,8 @@ for load in (0.0, CEIL - 500.0, CEIL, CEIL + 300.0, CEIL + 3000.0,
|
||||
_c = peakguard.claim(_d)
|
||||
if _c is not None and not (isinf(_c.hi) and _c.hi > 0):
|
||||
SWEEP_HI = False
|
||||
if _c is not None and _c.actuator != ACTUATOR_SITE:
|
||||
SWEEP_SITE = False
|
||||
print(f" swept {SWEEP_N} (load x elapsed x battery x SoC x floor) "
|
||||
f"combinations, SoC included: {SWEEP_NEG} negative floors, "
|
||||
f"{SWEEP_BOTH} decisions both floor-limited and saturated")
|
||||
@@ -1548,6 +1627,12 @@ check(f"NOT ONE of the {SWEEP_N} combinations produces a negative floor. That "
|
||||
SWEEP_NEG == 0 and SWEEP_N > 600)
|
||||
check("...and `hi` stays +inf on every claim any of them files",
|
||||
SWEEP_HI)
|
||||
check("...and every one of them is filed on the SITE actuator, which is the "
|
||||
"other half of the same asymmetry now that a claim has an actuator: the "
|
||||
"billed quantity is the quarter's offtake AT THE GRID CONNECTION, so a "
|
||||
"floor that bound one inverter's share would leave the site - the thing "
|
||||
"the capacity tariff meters - with no floor at all",
|
||||
SWEEP_SITE)
|
||||
check("...and no combination is both floor-limited and saturated, so the two "
|
||||
"notifications are exclusive on measured inputs and not merely by reading "
|
||||
"the code", SWEEP_BOTH == 0)
|
||||
@@ -2316,8 +2401,28 @@ check("...and so does the persistent notification, which outlives the page and "
|
||||
# "deferred" is exactly the state in which a ninth source gets built by
|
||||
# accident. Its revisit trigger is ALLOC-01, under which the reserve becomes a
|
||||
# PER-INVERTER interval at the allocator rather than a ninth claim here.
|
||||
# ⚠️ SAFETY-31 ADDED THE NINTH, DELIBERATELY, AND THIS IS THE PARAGRAPH THAT
|
||||
# SENTENCE ASKS FOR. `circulation` is a SET at P_SAFETY on the SITE actuator,
|
||||
# filed only while `circ_wd.tripped`. It is not the deferred loop-side reserve
|
||||
# this tripwire was built to catch: it is not conditioned on a state of charge,
|
||||
# it does not shape the loop, and it appears in NO cycle of the sweeps below -
|
||||
# the dynamic halves of this part still observe exactly {device, supervised,
|
||||
# loop} at every SoC from 0 to 100 %, because nothing in those fixtures
|
||||
# circulates. What it does is stop the site when two inverters are measured
|
||||
# pushing against each other. See DECISIONS/SAFETY-31-circulating-power.md.
|
||||
# ⚠️ SAFETY-30 ADDED THE TENTH, AND IT NEEDS ITS OWN PARAGRAPH FOR THE REASON
|
||||
# `circulation` needed one. `sign_site` is a SET at P_SAFETY on the SITE
|
||||
# actuator, filed only while `site_sign_wd.tripped` AND the roster holds more
|
||||
# than one inverter. It is not a second copy of `failsafe`: that one grades ONE
|
||||
# unit's command against THAT unit's own measured power and parks that unit,
|
||||
# while this grades the SUM of the commands against the meter and stops the
|
||||
# site. It appears in NO cycle of the sweeps below - the dynamic halves still
|
||||
# observe exactly {device, supervised, loop} at every SoC, because the shipped
|
||||
# roster is one inverter and this claim cannot be filed there at all. See
|
||||
# DECISIONS/SAFETY-30-per-unit-sign.md.
|
||||
CLAIM_SOURCES = {"device", "supervised", "failsafe", "safety", "peak",
|
||||
"arbitrage", "maintenance", "loop"}
|
||||
"arbitrage", "maintenance", "loop", "circulation",
|
||||
"sign_site"}
|
||||
# The two appends that file a claim BUILT ELSEWHERE in the method. Named here so
|
||||
# that a THIRD such indirection reads as an unrecognised append rather than as a
|
||||
# silent gap in the scan.
|
||||
@@ -2358,7 +2463,7 @@ check("every `claims.append(...)` in main.py's cycle is one this scan can READ "
|
||||
"- a claim filed through a shape it cannot parse has to fail here rather "
|
||||
"than be counted as nothing, which is how a scan like this goes quietly "
|
||||
"vacuous", len(_appends) >= 10 and None not in _filed)
|
||||
check("...and the sources that cycle can file are EXACTLY these eight. THIS is "
|
||||
check("...and the sources that cycle can file are EXACTLY these nine. THIS is "
|
||||
"what makes part 10 a tripwire: replay_loop() hand-builds the claim list, "
|
||||
"so it cannot see a claim main.py adds - and a loop-side SoC reserve is a "
|
||||
"NINTH source. Filing one takes this line red on the line it is written",
|
||||
@@ -2376,9 +2481,17 @@ def cycle_claims(run):
|
||||
seen = []
|
||||
real = app_main.resolve
|
||||
|
||||
def _spy(claims):
|
||||
def _spy(claims, **kw):
|
||||
# ⚠️ `**kw` PASSES THE ROSTER THROUGH UNREAD, AND THAT IS THE WHOLE
|
||||
# ADAPTATION ARB-03 MADE HERE. main.py now calls
|
||||
# `resolve(claims, units=self.units)`; a spy with a fixed signature would
|
||||
# raise a TypeError on every real cycle, which is loud, but a spy that
|
||||
# DROPPED the roster would be silently grading a different arbitration
|
||||
# from the one main.py performs. What is observed - `claims`, the list
|
||||
# itself - is unchanged, so the two halves below still see exactly what
|
||||
# they saw before, and a ninth source still goes red.
|
||||
seen.append(list(claims))
|
||||
return real(claims)
|
||||
return real(claims, **kw)
|
||||
|
||||
app_main.resolve = _spy
|
||||
try:
|
||||
@@ -2467,6 +2580,576 @@ check("...and replay_loop() folding main.py's TWO P_SAFETY rating limits into "
|
||||
and near(LOOP_MAX_W, read_option("max_w")))
|
||||
|
||||
|
||||
# --- 10g. ARB-03: AND THE ACTUATOR EACH OF THEM IS FILED ON -----------------
|
||||
# ⚠️ THE SAME PIN, ONE DIMENSION WIDER, AND FOR THE SAME REASON. 10f pins WHICH
|
||||
# sources main.py can file. ARB-03 gave every claim an `actuator`, and a claim
|
||||
# routed to the wrong stage is a defect 10f cannot see: the source set is
|
||||
# unchanged when the peak floor is misfiled onto one inverter, and the site is
|
||||
# then left with no floor at all in the quarter that sets the month's bill.
|
||||
#
|
||||
# It is also what keeps SAFETY-25 §0c honest from the other side. That table
|
||||
# says the deferred loop reserve becomes a PER-INVERTER `hi` at stage A while
|
||||
# the peak floor stays a SITE `lo` at stage B, and calls the crossing
|
||||
# structurally impossible. The structure is `CLAIM_SCOPE`, so `CLAIM_SCOPE` is
|
||||
# pinned to the AST-scanned set rather than trusted to agree with it.
|
||||
check("every source main.py can file is CLASSIFIED site or per-inverter, and "
|
||||
"nothing else is. A TENTH source now goes red twice - once here for "
|
||||
"having no classification, once above for being a tenth - and it takes an "
|
||||
"argument about what the claim is ABOUT to make either line green",
|
||||
set(CLAIM_SCOPE) == CLAIM_SOURCES)
|
||||
print(" site: " + ", ".join(sorted(s for s, v in CLAIM_SCOPE.items()
|
||||
if v == SCOPE_SITE))
|
||||
+ " | per-inverter: "
|
||||
+ ", ".join(sorted(s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT)))
|
||||
check("...and the split is the one ARB-03 argued, with SAFETY-31's and "
|
||||
"SAFETY-30's additions: the six about the GRID CONNECTION are site "
|
||||
"claims and the four about a pack, a device or one write are "
|
||||
"per-inverter. `circulation` is a site claim because its quantity is "
|
||||
"defined over the roster and is identically zero for any one unit; "
|
||||
"`sign_site` is one because the number that tripped it is the SITE "
|
||||
"target, which no single inverter owns - while `failsafe` beside it is "
|
||||
"per-inverter because since SAFETY-30 it grades one unit's command "
|
||||
"against that unit's OWN measured power",
|
||||
{s for s, v in CLAIM_SCOPE.items() if v == SCOPE_SITE}
|
||||
== {"loop", "peak", "arbitrage", "safety", "circulation", "sign_site"}
|
||||
and {s for s, v in CLAIM_SCOPE.items() if v == SCOPE_UNIT}
|
||||
== {"device", "supervised", "failsafe", "maintenance"})
|
||||
|
||||
# The shipped roster is ONE inverter, so §6.2's identity holds and every claim a
|
||||
# real cycle files is a site claim. Observed on the claims main.py's own resolve
|
||||
# was handed, not assumed from the routing table.
|
||||
_real_acts = {(c.source, c.actuator) for c in _cl}
|
||||
print(f" the real FLOOR-LIMITED cycle files: "
|
||||
+ ", ".join(f"{s}@{a}" for s, a in sorted(_real_acts)))
|
||||
check("at the SHIPPED one-inverter roster every claim a real cycle files is on "
|
||||
"the SITE actuator, per-inverter sources included. That is §6.2's "
|
||||
"identity - one inverter means the fabricated grid reading and the "
|
||||
"battery setpoint are the same number, so there is one actuator and it is "
|
||||
"both - and it is why ARB-03 is a pure refactor here",
|
||||
all(a == ACTUATOR_SITE for _, a in _real_acts))
|
||||
check("...and the arbiter agrees the routing is legal, on the list main.py "
|
||||
"actually handed it", scope_violations(_cl) == [])
|
||||
|
||||
# And the day the roster grows, the SAME cycle must partition. Graded through
|
||||
# main.py's own `actuator_of()` on a real Controller - the method every
|
||||
# `claims.append` above routes through - rather than through a copy of it.
|
||||
#
|
||||
# ⚠️ DEV-02: THE ROSTER IS GROWN BY ADDING A REAL `Inverter`, NOT BY SETTING
|
||||
# `c.units`. It used to be a tuple somebody could assign beside a roster of one,
|
||||
# i.e. a site claiming two actuators with one writer - which is a half-driven
|
||||
# site with nothing to say so - and `Controller.units` is now DERIVED from
|
||||
# `Controller.inverters` and has no setter. Building the object is also what
|
||||
# makes these checks mean more than they did: the second unit has its own
|
||||
# setpoint entity, its own rating and its own device range, so the claims below
|
||||
# are filed from ITS numbers rather than from a copy of A's.
|
||||
#
|
||||
# ⚠️ INVERTER B DOES NOT EXIST YET. Its rating here is a HYPOTHESIS: nothing in
|
||||
# this file is a measured parameter for a second device (SPIKE-04 measures one).
|
||||
# What is graded is the ARCHITECTURE - which actuator each claim lands on, and
|
||||
# whose number each per-unit bound is built from.
|
||||
#
|
||||
# ⚠️ AND IT IS 3000 W RATHER THAN A's 5000 W, WHICH IS NOT COSMETIC. THE RULE,
|
||||
# STATED AT THE LINE THAT NEEDED IT: ANY CHECK ASSERTING "X DIFFERS FROM Y" MUST
|
||||
# BE RUN ONCE WITH X AND Y ACTUALLY MADE DIFFERENT. This helper used to default
|
||||
# B's rating and device range to A's `LIVE_MAX_W`, and the AC 4 check below
|
||||
# compared inverter B's `supervised` bound against `_b2.max_w` - which was
|
||||
# LITERALLY THE SAME NUMBER as A's. It read as evidence and observed nothing:
|
||||
# filing both per-unit claims from `self.inverters[0]`'s numbers instead of
|
||||
# `inv`'s left all 19 files green. That is the third check this session whose
|
||||
# DATA could not reach the failure it named (ARB-03's call-site scan saw 3 of 8
|
||||
# sites; ALLOC-01's replay generator saw 0 escapes where a widened one saw
|
||||
# 39,991), so the number is different HERE, once, for every fixture in the file.
|
||||
B_RATING_HYPOTHESIS = LIVE_MAX_W - 2000.0
|
||||
|
||||
|
||||
def second_inverter(ctl, *, name="inverter-b", setpoint="number.sp_b",
|
||||
max_w=None, dev=None):
|
||||
"""Append a real second `Inverter` to `ctl`, and return a restore()."""
|
||||
rating = B_RATING_HYPOTHESIS if max_w is None else max_w
|
||||
inv = Inverter(name, setpoint_entity=setpoint, soc_entity="sensor.soc_b",
|
||||
batt_entity="sensor.batt_b", max_w=rating, store=ctl.store)
|
||||
inv.dev_min, inv.dev_max = dev or (-rating, rating)
|
||||
# The readings a real cycle needs from it. `inputs_ok` requires EVERY unit
|
||||
# to have answered, which is the point - a pack nothing can grade stops the
|
||||
# site rather than being quietly dropped from the split.
|
||||
inv.soc, inv.batt = ctl.inverters[0].soc, 0.0
|
||||
original = list(ctl.inverters)
|
||||
ctl.inverters.append(inv)
|
||||
|
||||
def restore():
|
||||
ctl.inverters[:] = original
|
||||
return inv, restore
|
||||
|
||||
|
||||
_b, _restore_b = second_inverter(c_src)
|
||||
_routed = {s: c_src.actuator_of(s) for s in CLAIM_SOURCES}
|
||||
_restore_b()
|
||||
print(" with a second inverter on the roster, main.py routes: "
|
||||
+ ", ".join(f"{s}->{a}" for s, a in sorted(_routed.items())))
|
||||
check("⚠️ AND THIS IS THE BREAKING HALF. Give the same Controller a second "
|
||||
"inverter and its OWN routing method splits the ten: `device`, "
|
||||
"`supervised`, `failsafe` and `maintenance` bind the unit this controller "
|
||||
"drives, `loop`, `peak`, `arbitrage`, `safety`, SAFETY-31's `circulation` "
|
||||
"and SAFETY-30's `sign_site` stay on the grid connection. Swap any one of "
|
||||
"them - route `peak` to the unit and the site keeps no floor; route "
|
||||
"`maintenance` to the site and it can cross that floor into `lo > hi`; "
|
||||
"route `circulation` to one unit and a site-wide loop parks the inverter "
|
||||
"that may well be the one still listening; route `sign_site` to one unit "
|
||||
"and a SITE total pointing the wrong way parks one inverter while the "
|
||||
"rest of the roster goes on pushing the same way - and this line goes red",
|
||||
_routed == {"device": "inverter-a", "supervised": "inverter-a",
|
||||
"failsafe": "inverter-a", "maintenance": "inverter-a",
|
||||
"loop": ACTUATOR_SITE, "peak": ACTUATOR_SITE,
|
||||
"arbitrage": ACTUATOR_SITE, "safety": ACTUATOR_SITE,
|
||||
"circulation": ACTUATOR_SITE, "sign_site": ACTUATOR_SITE})
|
||||
check("...and the roster it was restored to is the shipped one, so nothing "
|
||||
"below inherits a two-inverter Controller",
|
||||
c_src.units == (app_main.UNIT_A,) and len(c_src.inverters) == 1)
|
||||
|
||||
# ⚠️ AND THE ROUTING TABLE BEING RIGHT IS NOT THE SAME AS THE CALL SITES USING
|
||||
# IT RIGHT. `actuator_of("maintenance")` written at the `device` append routes a
|
||||
# rating limit to whatever `maintenance` routes to, and at the shipped
|
||||
# one-inverter roster BOTH answers are the site, so nothing above can see it.
|
||||
# ⚠️ AND THE DYNAMIC CYCLE BELOW SEES ONLY THREE OF THE NINE DIRECT APPENDS.
|
||||
# That was THIS PART committing this repository's own named failure - a check
|
||||
# observing something other than what it claimed - inside the check written to
|
||||
# prevent it. The first cut of 10g called the two-inverter cycle "the line a
|
||||
# mis-typed `actuator_of(...)` at a call site goes red on", full stop. IT IS
|
||||
# NOT. That cycle is auto, P1-healthy, no maintenance procedure, no tripped sign
|
||||
# watchdog, the guard idle and arbitrage off, so it reaches `device`,
|
||||
# `supervised` and `loop` AND NOTHING ELSE. PR #40's reviewer mutated the other
|
||||
# five appends one at a time and every suite in this repository stayed GREEN,
|
||||
# this part included. At the maintenance-shaping append,
|
||||
# `actuator_of("maintenance")` -> `actuator_of("peak")` then produced, at a
|
||||
# roster of two, a site loop of -1500 W against the guard's site `lo` of 1500 W
|
||||
# and the now-misrouted charge-only `hi = 0`: `lo > hi`, arbiter clause 3, 0 W
|
||||
# IN THE BILLED QUARTER - SAFETY-25 §0a's fatal case, built by a one-word typo
|
||||
# under a green suite. The same mutation at the `failsafe` append survived too.
|
||||
#
|
||||
# So THE CALL SITES ARE PINNED STATICALLY, over 10f's own AST scan of
|
||||
# `Controller.cycle()` and for 10f's reason: a static pin sees every append on
|
||||
# the line it is written, in every configuration, whether or not any fixture
|
||||
# here reaches the state that files it. All eight direct appends expose their
|
||||
# actuator as a LITERAL - `actuator=self.actuator_of('<source>')` - so the
|
||||
# literal is simply required to EQUAL the source the claim is filed under. That
|
||||
# is what makes "a mis-typed `actuator_of(...)` goes red" a true sentence about
|
||||
# all ten rather than about the three a fixture happens to reach.
|
||||
|
||||
|
||||
def append_actuator(node):
|
||||
"""The actuator expression a DIRECT append routes its claim through.
|
||||
|
||||
⚠️ RETURNED AS SOURCE TEXT, NOT EVALUATED, and that is the whole point.
|
||||
`self.actuator_of('device')` and `self.actuator_of('maintenance')` are the
|
||||
SAME VALUE at the shipped roster and two different routings; only the text
|
||||
written at the call site tells them apart, which is exactly why every
|
||||
dynamic check in this file is blind to the swap at N=1.
|
||||
"""
|
||||
kw = [k for k in node.keywords if k.arg == "actuator"]
|
||||
if len(kw) != 1:
|
||||
return None
|
||||
return ast.unparse(kw[0].value)
|
||||
|
||||
|
||||
# The appends that BUILD their claim in place - the nine whose routing is
|
||||
# chosen by hand, and the only ones where a typo is possible - against the two
|
||||
# that append a claim built elsewhere in the method and carry no `actuator=`
|
||||
# here at all.
|
||||
_direct = [n.args[0] for n in _appends if isinstance(n.args[0], ast.Call)]
|
||||
_indirect = [n.args[0].id for n in _appends if isinstance(n.args[0], ast.Name)]
|
||||
_routing = sorted(((c.args[0].value, append_actuator(c), c.lineno)
|
||||
for c in _direct), key=lambda r: r[2])
|
||||
# ⚠️ DEV-02 GAVE `actuator_of()` A SECOND ARGUMENT - the roster entry the claim
|
||||
# is ABOUT - so a per-inverter append inside the `for inv in self.inverters:`
|
||||
# loop reads `self.actuator_of('device', inv)`. The pin is unchanged in what it
|
||||
# grades: the FIRST argument, the string literal, must still be the source the
|
||||
# claim is filed under. What the second argument may be is deliberately NOT
|
||||
# constrained here - it is a roster entry, and which one is a question the
|
||||
# dynamic two-inverter cycle below answers on real claims - but its PRESENCE is,
|
||||
# because a per-inverter claim built in that loop and routed with no `inv` files
|
||||
# inverter B's rating on inverter A. That is graded at the line: a source
|
||||
# classified SCOPE_UNIT must pass one.
|
||||
def _routing_literal(a):
|
||||
"""The first argument of `self.actuator_of(...)`, or None if it is not one."""
|
||||
if not a.startswith("self.actuator_of("):
|
||||
return None
|
||||
return a[len("self.actuator_of("):-1].split(",")[0].strip()
|
||||
|
||||
|
||||
_misrouted = [r for r in _routing if _routing_literal(r[1]) != repr(r[0])]
|
||||
_unit_sources_unrouted = [
|
||||
r for r in _routing
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT and "," not in r[1]]
|
||||
print(f" {len(_direct)} direct appends, each read at its own line: "
|
||||
+ ", ".join(f"main.py:{ln} {s} -> {a}" for s, a, ln in _routing))
|
||||
check("all TEN of `Controller.cycle()`'s DIRECT appends route through "
|
||||
"`self.actuator_of(<string literal>)`, so this scan can read the routing "
|
||||
"of EVERY one of them. An append that computed its actuator, or omitted "
|
||||
"the argument, or hand-wrote a string, fails HERE rather than being "
|
||||
"silently skipped - which is how a scan like this goes quietly vacuous, "
|
||||
"and 10f is in this file because that already happened once",
|
||||
len(_direct) == 10
|
||||
and all(a is not None and a.startswith("self.actuator_of('")
|
||||
for _s, a, _ln in _routing))
|
||||
check("⚠️ AND AT EVERY ONE OF THE TEN THE LITERAL IT ROUTES THROUGH IS THE "
|
||||
"SOURCE THE CLAIM IS FILED UNDER. THIS is the line a mis-typed "
|
||||
"`actuator_of(...)` at a call site goes red on - all nine of them, on "
|
||||
"the line the typo is written, at every roster, INCLUDING the six "
|
||||
"appends no fixture in this repository reaches. "
|
||||
"`actuator_of(\"peak\")` at the maintenance append is a different string "
|
||||
"here even though it is the same VALUE at the shipped roster of one",
|
||||
_misrouted == [])
|
||||
check("⚠️ AND EVERY PER-INVERTER APPEND NAMES THE INVERTER IT IS ABOUT. "
|
||||
"`actuator_of()` takes the roster entry as its second argument and "
|
||||
"defaults to the FIRST one when it is left out - which is right for the "
|
||||
"site-scoped sources and is the whole defect for a per-inverter one: a "
|
||||
"`device` limit built inside the roster loop and routed without `inv` "
|
||||
"files inverter B's rating on inverter A, where it binds the wrong "
|
||||
"share. Five of the ten appends are SCOPE_UNIT - `device`, "
|
||||
"`supervised`, `failsafe` and maintenance's two - and all five pass one. "
|
||||
"SAFETY-30's `sign_site` is deliberately NOT one of them: it is filed on "
|
||||
"the site, beside `circulation`, because the number that tripped it is "
|
||||
"the site target",
|
||||
_unit_sources_unrouted == []
|
||||
and len([r for r in _routing
|
||||
if CLAIM_SCOPE.get(r[0]) == SCOPE_UNIT]) == 5)
|
||||
check("...and the only appends this pin does NOT reach are the two that file a "
|
||||
"claim BUILT ELSEWHERE - `peak_claim` and `arb_claim` - which have no "
|
||||
"`actuator=` at the call site to mis-type. Their routing is pinned where "
|
||||
"it is CHOSEN instead: peakguard.claim() by the SWEEP_SITE sweep above, "
|
||||
"over every load x elapsed x battery x SoC x floor combination, and "
|
||||
"arbitrage.claim() by test_arbitrage.py",
|
||||
sorted(_indirect) == sorted(CLAIM_BUILDERS)
|
||||
and len(_direct) + len(_indirect) == len(_appends))
|
||||
check("...and between them the eleven appends account for exactly the nine "
|
||||
"sources 10f pins, so the routing pin and the source set are one scan "
|
||||
"and neither can drift from the other",
|
||||
{s for s, _a, _ln in _routing} | set(CLAIM_BUILDERS.values())
|
||||
== CLAIM_SOURCES)
|
||||
|
||||
# THE DYNAMIC HALF, kept, and now stated for what it actually observes: a real
|
||||
# cycle proving the routing reaches the arbiter THROUGH main.py rather than only
|
||||
# through this file's reading of main.py. It grades three of the eight appends.
|
||||
# The static pin above is what covers the other five.
|
||||
_b2, _restore_b2 = second_inverter(c_src)
|
||||
_n2_writes_before = len(c_src.hass.per_entity)
|
||||
try:
|
||||
_, _cl2 = cycle_claims(lambda: run_cycle(c_src))
|
||||
_n2_target, _n2_reason = c_src.target, c_src.reason
|
||||
_n2_events = list(c_src.events)
|
||||
_n2_writes = c_src.hass.per_entity[_n2_writes_before:]
|
||||
_n2_shares = {i.name: i.target for i in c_src.inverters}
|
||||
_n2_last = {i.name: i.last_write for i in c_src.inverters}
|
||||
_n2_alloc = c_src.allocation
|
||||
finally:
|
||||
_restore_b2()
|
||||
print(" a REAL two-inverter cycle files: "
|
||||
+ ", ".join(f"{c.source}@{c.actuator}" for c in _cl2))
|
||||
check("a real cycle at a roster of TWO partitions its own claims correctly - "
|
||||
"every claim main.py filed is on an actuator its source's scope permits, "
|
||||
"observed on the list main.py's own `resolve` was handed. ⚠️ AND THIS "
|
||||
"SEES THREE OF THE EIGHT APPENDS, NOT THE CLASS: this state files "
|
||||
"`device`, `supervised` and `loop`, so it is the static pin above and not "
|
||||
"this line that covers `failsafe`, `safety` and the two `maintenance` "
|
||||
"appends", len(_cl2) >= 3 and scope_violations(_cl2) == [])
|
||||
check("⚠️ AND THE RATING LIMITS ARE FILED ONCE PER INVERTER, ON ITS OWN "
|
||||
"ACTUATOR - which is DEV-02 in one line. Before this card there was ONE "
|
||||
"`device` pair, read from ONE `setpoint_entity`, filed once: a second "
|
||||
"inverter's rating was never read and never bound anything, so its share "
|
||||
"was clamped against the first one's numbers. Now the loop over the "
|
||||
"roster files a pair per unit and the loop claim stays on the grid "
|
||||
"connection",
|
||||
sorted((c.source, c.actuator) for c in _cl2)
|
||||
== [("device", "inverter-a"), ("device", "inverter-b"),
|
||||
("loop", ACTUATOR_SITE), ("supervised", "inverter-a"),
|
||||
("supervised", "inverter-b")])
|
||||
check("...and naming those three is not an accident of this fixture but the "
|
||||
"reason the static pin exists - SEVEN of the ten sources need a state "
|
||||
"no check in this file reaches. SAFETY-31's `circulation` is one of the "
|
||||
"seven: it is filed only while the site is MEASURED to be circulating, "
|
||||
"which no fixture here is. SAFETY-30's `sign_site` is another, and it "
|
||||
"needs TWO states at once - a roster of two AND the site's total command "
|
||||
"standing opposed to the meter for its whole window",
|
||||
{c.source for c in _cl2}
|
||||
== CLAIM_SOURCES - {"failsafe", "safety", "maintenance", "peak",
|
||||
"arbitrage", "circulation", "sign_site"})
|
||||
# ⚠️ AND NOW THE HALF THAT WAS EVIDENCE-SHAPED AND OBSERVED NOTHING. The three
|
||||
# checks above grade WHICH ACTUATOR each claim lands on. They say nothing about
|
||||
# WHOSE NUMBERS the bound is built from - and those are two different defects
|
||||
# with two different fixes. Filing the per-unit `device` and `supervised` claims
|
||||
# from `self.inverters[0]`'s numbers while leaving `actuator=self.actuator_of(
|
||||
# ..., inv)` alone routes every claim correctly and bounds inverter B by
|
||||
# inverter A's rating: at A=5000/B=3000 the planned envelope for inverter-b
|
||||
# becomes (-5000, 5000) instead of (-3000, 3000), which is a 2000 W
|
||||
# over-command the arbiter believes is supervised.
|
||||
#
|
||||
# ⚠️ THE RULE THIS LINE EXISTS TO OBEY: ANY CHECK ASSERTING "X DIFFERS FROM Y"
|
||||
# MUST BE RUN ONCE WITH X AND Y ACTUALLY MADE DIFFERENT. The version this
|
||||
# replaces compared inverter B's bound against `_b2.max_w` while
|
||||
# `second_inverter()` defaulted `max_w` to A's `LIVE_MAX_W` - so it compared
|
||||
# 5000 against 5000, and the mutation above left all 19 files GREEN. The
|
||||
# PRECONDITION below is what stops that happening again: it fails if the two
|
||||
# ratings are ever made equal, so the check cannot go quietly vacuous.
|
||||
_sup2 = {c.actuator: (c.lo, c.hi) for c in _cl2 if c.source == "supervised"}
|
||||
_dev2 = {c.actuator: (c.lo, c.hi) for c in _cl2 if c.source == "device"}
|
||||
print(f" supervised bounds by actuator: {_sup2}; device bounds: {_dev2}")
|
||||
check("PRECONDITION, AND IT IS THE WHOLE POINT: A AND B HAVE DIFFERENT "
|
||||
"RATINGS. A check that 'B's bound is B's own number' cannot observe "
|
||||
"anything while B's number IS A's number, and this file shipped that "
|
||||
"check for a whole review round",
|
||||
_b2.max_w != c_src.inverters[0].max_w
|
||||
and (_b2.dev_min, _b2.dev_max)
|
||||
!= (c_src.inverters[0].dev_min, c_src.inverters[0].dev_max))
|
||||
check("⚠️ AND EACH UNIT'S `supervised` BOUND IS ITS OWN `max_w`, NOT A COPY OF "
|
||||
"THE FIRST UNIT'S. That is the sentence AC 4 is, and it is now stated "
|
||||
"against LITERAL, DIFFERENT numbers rather than against an expression "
|
||||
"that could be reading the same object twice: B is bounded at "
|
||||
f"+/-{B_RATING_HYPOTHESIS:.0f} W and A at +/-{LIVE_MAX_W:.0f} W",
|
||||
_sup2 == {"inverter-a": (-LIVE_MAX_W, LIVE_MAX_W),
|
||||
"inverter-b": (-B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS)})
|
||||
check("...and so is each unit's `device` bound, which is the other number the "
|
||||
"same loop files and the one that was NEVER READ before this card - one "
|
||||
"`dev_min`/`dev_max` pair came off one `setpoint_entity`, so a second "
|
||||
"inverter's reported range bound nothing at all",
|
||||
_dev2 == {"inverter-a": (-LIVE_MAX_W, LIVE_MAX_W),
|
||||
"inverter-b": (-B_RATING_HYPOTHESIS, B_RATING_HYPOTHESIS)})
|
||||
check("...and the bounds the ARBITER RESOLVED for inverter B - not just the "
|
||||
"claims filed at it - are B's own, because a claim filed correctly and "
|
||||
"then resolved against the wrong envelope would be the same defect one "
|
||||
"layer down",
|
||||
_n2_alloc is not None
|
||||
and next((p for p in _n2_alloc.plans if p.unit == "inverter-b"), None)
|
||||
is not None
|
||||
and (lambda p: p.lo == -B_RATING_HYPOTHESIS
|
||||
and p.hi == B_RATING_HYPOTHESIS)(
|
||||
next(p for p in _n2_alloc.plans if p.unit == "inverter-b")))
|
||||
|
||||
|
||||
# --- 10h. ALLOC-01: WHAT MAIN.PY DOES WITH AN ALLOCATION IT CANNOT DELIVER ---
|
||||
# ⚠️ THIS PART WAS WRITTEN AGAINST `allocated=False` AND HAS BEEN RE-AIMED, NOT
|
||||
# DELETED. ARB-03's `allocate()` declined at every roster of two or more,
|
||||
# because it had no allocator and the obvious placeholder - hand the site target
|
||||
# to each inverter - IS the ARCH-01 fault. ALLOC-01 filled the seam, so that
|
||||
# trigger is gone. The branch is NOT, and this part is why it had better not be:
|
||||
# PR #40's reviewer replaced main.py's `if not resolution.allocated:` with
|
||||
# `if False:` and the whole 17-file suite stayed GREEN, so an unreachable-but-
|
||||
# right instinct was one refactor away from being deleted as dead code.
|
||||
# Removing the trigger without giving the branch a new one would rebuild that
|
||||
# hole exactly.
|
||||
#
|
||||
# THERE ARE NOW TWO REFUSALS AND THEY ARE DIFFERENT REFUSALS, so all three
|
||||
# states below are driven as REAL CYCLES through `Controller.cycle()`:
|
||||
#
|
||||
# 10h-1 the allocator SUCCEEDS and this controller cannot deliver the split.
|
||||
# 10h-2 one inverter's master is stale: the survivor carries the whole site
|
||||
# target, WHICH IS DELIVERABLE, and the drop is announced (AC 6).
|
||||
# 10h-3 every master is stale: no envelope set, so the allocator itself
|
||||
# refuses and `allocated=False` is reached for real.
|
||||
#
|
||||
# ⚠️ AND 10h-1 IS THE HALF DEV-02 CHANGED, SO IT HAS BEEN RE-AIMED AGAIN AND
|
||||
# THE PREVIOUS AIM IS RECORDED HERE RATHER THAN DELETED. ALLOC-01 had to ADD
|
||||
# this guard: there was one `setpoint_entity` in this add-on, so a controller
|
||||
# handed a valid 450/450 split and a roster of two would have written
|
||||
# `self.target` - 900, the SITE number - to the single inverter it could reach
|
||||
# while a second sat uncommanded. Not the broadcast fault, but the same shape of
|
||||
# over-command.
|
||||
#
|
||||
# DEV-02 gives it a writer per inverter, so that trigger is gone and the
|
||||
# deliverable case is now the ORDINARY one: both units are commanded THEIR OWN
|
||||
# SHARE, which is what 10h-1 grades below. The refusal survives with a trigger
|
||||
# it can still reach - a roster entry with NO setpoint entity of its own - and
|
||||
# 10h-1b drives it.
|
||||
print(f" at N=2 the allocator produced {_n2_alloc.explain()}")
|
||||
print(f" and main.py resolved to {_n2_target:+.0f} W, reason "
|
||||
f"{_n2_reason!r}, wrote {_n2_writes}")
|
||||
print(" and logged: "
|
||||
+ next((e for e in _n2_events if "ARBITER" in e), "(nothing)"))
|
||||
check("⚠️ THE ALLOCATOR NOW SUCCEEDS AT A ROSTER OF TWO, and the shares SUM to "
|
||||
"the site target exactly rather than repeating it. That sum is the whole "
|
||||
"safety property: it makes the gain at the meter a convex combination of "
|
||||
"the per-unit gains, where a broadcast makes it N times the per-unit "
|
||||
"gain - 4000 W peak-to-peak forever at gain 1.0 on admin/goodwe's "
|
||||
"two-master rig, with not one guard firing",
|
||||
_n2_alloc.ok and sorted(_n2_alloc.shares) == ["inverter-a", "inverter-b"]
|
||||
and sum(_n2_alloc.shares.values()) == _n2_alloc.sum_w
|
||||
and _n2_alloc.unmet_w == 0)
|
||||
check("...and it did NOT broadcast: neither share is the site target, and "
|
||||
"THAT is the line a placeholder `{u: target for u in units}` goes red on",
|
||||
all(v != _n2_alloc.sum_w for v in _n2_alloc.shares.values())
|
||||
or _n2_alloc.sum_w == 0)
|
||||
check("⚠️ AND MAIN.PY NOW DELIVERS THE SPLIT. THIS IS DEV-02'S DELIVERABLE, "
|
||||
"and it is the line that used to read 'refusing to command a partial "
|
||||
"site'. Each inverter is written ITS OWN SHARE, to ITS OWN setpoint "
|
||||
"entity, in one cycle - two entities, two numbers, and the two numbers "
|
||||
"are the allocator's, not the site target repeated",
|
||||
sorted(_n2_writes)
|
||||
== sorted([("number.sp", float(_n2_alloc.shares["inverter-a"])),
|
||||
("number.sp_b", float(_n2_alloc.shares["inverter-b"]))]))
|
||||
check("...and neither entity was handed the SITE target, which is the "
|
||||
"broadcast fault stated as a check on the wire rather than on the "
|
||||
"allocator. Each unit supplying the site number IN FULL is 4000 W "
|
||||
"peak-to-peak forever at gain 1.0 on admin/goodwe's two-master rig, with "
|
||||
"not one guard firing",
|
||||
_n2_target == 0.0 or all(v != _n2_target for _e, v in _n2_writes))
|
||||
check("...and the resolution is NOT the 0 W failsafe any more: the site target "
|
||||
"is a real number and it reached the hardware. That is the whole "
|
||||
"difference this card makes to this part",
|
||||
_n2_target != 0.0 and "failsafe" not in _n2_reason)
|
||||
check("...and each inverter's own `last_write` records what IT was told, so "
|
||||
"the heartbeat re-emits a SHARE rather than the site number and "
|
||||
"SAFETY-02 grades each unit against the command IT is standing on",
|
||||
_n2_last == {u: float(v) for u, v in _n2_alloc.shares.items()})
|
||||
check("...and the action log no longer carries the 'no writer' refusal, "
|
||||
"because there is a writer. This is the line that goes red if that "
|
||||
"branch is left standing with its old trigger",
|
||||
not any("no writer" in e for e in _n2_events))
|
||||
|
||||
# --- 10h-1b. THE RE-AIMED REFUSAL: A ROSTER ENTRY WITH NO WRITER ------------
|
||||
# ⚠️ THE INSTINCT SURVIVES ITS TRIGGER, WHICH IS WHAT ALLOC-01 ASKED FOR WHEN IT
|
||||
# SAID RE-AIM RATHER THAN DELETE - and PR #40's reviewer is why: replacing
|
||||
# main.py's sibling branch with `if False:` left the whole suite green, so an
|
||||
# unreachable-but-right guard was one refactor from being deleted as dead code.
|
||||
# A configured inverter with no `setpoint_entity` of its own is still a unit
|
||||
# this controller cannot put a number on, and commanding the ones it CAN reach
|
||||
# would over-command them by exactly the missing unit's share.
|
||||
_nw, _restore_nw = second_inverter(c_src, name="inverter-c", setpoint="")
|
||||
_nw_writes_before = len(c_src.hass.per_entity)
|
||||
try:
|
||||
_, _cl_nw = cycle_claims(lambda: run_cycle(c_src))
|
||||
_nw_target, _nw_reason = c_src.target, c_src.reason
|
||||
_nw_events = list(c_src.events)
|
||||
_nw_writes = c_src.hass.per_entity[_nw_writes_before:]
|
||||
finally:
|
||||
_restore_nw()
|
||||
print(f" a roster entry with no setpoint entity: main.py resolved to "
|
||||
f"{_nw_target:+.0f} W, reason {_nw_reason!r}, wrote {_nw_writes}")
|
||||
print(" and logged: "
|
||||
+ next((e for e in _nw_events if "ARBITER" in e), "(nothing)"))
|
||||
check("⚠️ A UNIT WITH NO WRITER TAKES THE SITE TO THE 0 W FAILSAFE. It is a "
|
||||
"CONFIGURATION that cannot be delivered - not a link that went away, "
|
||||
"which is the dropped case below and is announced and survived - and a "
|
||||
"site running at part strength on a roster somebody wrote down wrong "
|
||||
"reads as healthy on every dashboard",
|
||||
_nw_target == 0.0 and "failsafe" in _nw_reason)
|
||||
check("...and it says WHY, naming the inverter it has no setpoint entity for",
|
||||
any("no setpoint entity for inverter-c" in e for e in _nw_events))
|
||||
check("...and then it WRITES that 0 W to the unit it CAN reach, on the same "
|
||||
"line as every other cycle. A substitution, not an abstention: the "
|
||||
"inverter holds its last command forever, so failing toward inaction "
|
||||
"means commanding zero, not falling silent",
|
||||
_nw_writes == [("number.sp", 0.0)])
|
||||
check("...and the 0 W is NOT what the site target happened to be - the same "
|
||||
"claims at a roster whose units all have writers resolve to a real "
|
||||
"number, which is what says the branch does work rather than agreeing "
|
||||
"with the resolution by luck",
|
||||
resolve(_cl_nw, units=("inverter-a",)).allocated is True
|
||||
and resolve(_cl_nw, units=("inverter-a",)).target_w != 0.0)
|
||||
|
||||
# --- 10h-2. A DEAD LINK, AND THE SURVIVOR NOT ABSORBING IT SILENTLY ---------
|
||||
# ⚠️ STIMULATED THROUGH main.py's OWN SEAM, NOT THROUGH A PATCHED ARBITER.
|
||||
# `Controller.live_units()` is the production method the allocator's `live`
|
||||
# argument comes from.
|
||||
#
|
||||
# ⚠️ AND SINCE DEV-02 IT IS DRIVEN BY THE REAL STIMULUS RATHER THAN OVERRIDDEN.
|
||||
# This used to replace the method with a lambda, because at a roster of one
|
||||
# "its master is stale" had no expression separate from "this controller is
|
||||
# blind". `Inverter.is_live()` gives it one: a link whose every write has been
|
||||
# REJECTED for a whole `LINK_STALE_S` window is not commandable, which is layer
|
||||
# 1's own veto period - the point at which the firmware takes that inverter to
|
||||
# zero anyway. So inverter B is put into exactly that state and the shipped
|
||||
# method is asked, which is what makes this a check on `live_units()` instead of
|
||||
# a check on a lambda this file wrote.
|
||||
_bs, _restore_bs = second_inverter(c_src)
|
||||
_bs.rejected_since = datetime.now(timezone.utc) - timedelta(
|
||||
seconds=app_main.LINK_STALE_S + 5)
|
||||
_bs.last_write_ok = False
|
||||
_stale_writes_before = len(c_src.hass.per_entity)
|
||||
try:
|
||||
check("PRECONDITION: the SHIPPED `live_units()` - not a lambda - drops the "
|
||||
"inverter whose writes have been rejected for a whole layer-1 window, "
|
||||
"and keeps the healthy one",
|
||||
c_src.live_units() == ("inverter-a",))
|
||||
_, _cl_stale = cycle_claims(lambda: run_cycle(c_src))
|
||||
_stale_target = c_src.target
|
||||
_stale_alloc = c_src.allocation
|
||||
_stale_events = list(c_src.events)
|
||||
_stale_writes = c_src.hass.per_entity[_stale_writes_before:]
|
||||
finally:
|
||||
_restore_bs()
|
||||
print(f" inverter-b's master stale: {_stale_alloc.explain()}")
|
||||
print(" and logged: "
|
||||
+ next((e for e in _stale_events if "ALLOCATOR" in e), "(nothing)"))
|
||||
check("a unit whose master is stale is REMOVED FROM THE ENVELOPE SET rather "
|
||||
"than allocated into. An allocator that kept commanding a link it cannot "
|
||||
"reach is writing into a void and calling the site target met",
|
||||
_stale_alloc.dropped == (("inverter-b", ALLOC_DROP_STALE),)
|
||||
and "inverter-b" not in _stale_alloc.shares)
|
||||
check("...and the SURVIVOR CARRIES THE WHOLE SITE TARGET, which is right - "
|
||||
"there is one integrator on P1 and its output still has to be delivered - "
|
||||
"and it is now DELIVERABLE, so main.py writes it instead of failsafing. "
|
||||
"The two guards are distinguished by this line: a dead sibling is not the "
|
||||
"same event as a sibling with no writer",
|
||||
_stale_alloc.shares == {"inverter-a": _stale_alloc.sum_w}
|
||||
and _stale_target == float(_stale_alloc.sum_w)
|
||||
and ("number.sp", _stale_target) in _stale_writes)
|
||||
check("⚠️ AND THE DROPPED UNIT IS COMMANDED 0 W, NOT LEFT STANDING. The "
|
||||
"inverter holds its last command FOREVER - it has no meter timeout of its "
|
||||
"own - so 'not in the split' has to mean zero on the wire. Leaving it "
|
||||
"silent would leave a dead-link inverter pushing its last share while the "
|
||||
"survivor carried the whole site target on top of it",
|
||||
("number.sp_b", 0.0) in _stale_writes)
|
||||
check("⚠️ AND IT DOES NOT ABSORB IT SILENTLY, which is the whole of AC 6 and of "
|
||||
"SAFETY-30. The action log names the inverter, the reason it left, and "
|
||||
"the consequence - that what remains now carries its share. A site "
|
||||
"running at half its inverters and reporting nothing reads as a healthy "
|
||||
"site to the operator and to every dashboard",
|
||||
any("inverter-b" in e and "stale link" in e and "carry" in e
|
||||
for e in _stale_events))
|
||||
|
||||
# --- 10h-3. EVERY MASTER STALE: THE ALLOCATOR'S OWN REFUSAL, REACHED --------
|
||||
# Same stimulus, both units. ⚠️ AND IT REACHES A ROSTER OF ONE TOO: this is the
|
||||
# state `live_units()`'s own docstring warns about - the sole inverter dropping
|
||||
# takes the SITE to 0 W - so it is driven here rather than left as a sentence.
|
||||
_bd, _restore_bd = second_inverter(c_src)
|
||||
_gone = datetime.now(timezone.utc) - timedelta(
|
||||
seconds=app_main.LINK_STALE_S + 5)
|
||||
_bd.rejected_since, _bd.last_write_ok = _gone, False
|
||||
c_src.inverters[0].rejected_since = _gone
|
||||
c_src.inverters[0].last_write_ok = False
|
||||
_dead_writes_before = len(c_src.hass.per_entity)
|
||||
try:
|
||||
_, _cl_dead = cycle_claims(lambda: run_cycle(c_src))
|
||||
_dead_target, _dead_reason = c_src.target, c_src.reason
|
||||
_dead_alloc = c_src.allocation
|
||||
_dead_events = list(c_src.events)
|
||||
_dead_writes = [v for _e, v in c_src.hass.per_entity[_dead_writes_before:]]
|
||||
finally:
|
||||
_restore_bd()
|
||||
c_src.inverters[0].rejected_since = None
|
||||
c_src.inverters[0].last_write_ok = True
|
||||
print(f" every master stale: {_dead_alloc.explain()}")
|
||||
print(" and logged: "
|
||||
+ next((e for e in _dead_events if "ARBITER" in e), "(nothing)"))
|
||||
check("⚠️ AND HERE `allocated=False` IS REACHED FOR REAL, ON A REAL CYCLE. "
|
||||
"With no inverter in the envelope set there is nobody to allocate to, "
|
||||
"and inventing a share for a link nobody can reach is the failure this "
|
||||
"branch exists for. The refusal path ARB-03 left behind is therefore "
|
||||
"still live code with a live trigger, which is what the ticket asked for "
|
||||
"when it said re-aim rather than delete",
|
||||
_dead_alloc.ok is False and _dead_alloc.shares == {}
|
||||
and ALLOC_REFUSE_EMPTY in _dead_alloc.refused)
|
||||
check("...and main.py substitutes the 0 W failsafe on it, writes that 0 W, and "
|
||||
"puts the allocator's OWN sentence in the action log rather than a "
|
||||
"paraphrase - so the operator reads which of the refusals fired",
|
||||
_dead_target == 0.0 and "failsafe" in _dead_reason
|
||||
and set(_dead_writes) == {0.0} and len(_dead_writes) == 2
|
||||
and any("ARBITER: REFUSED" in e and ALLOC_REFUSE_EMPTY in e
|
||||
for e in _dead_events))
|
||||
check("...and the roster it was restored to is the shipped one, with a healthy "
|
||||
"link, so nothing below inherits a two-inverter Controller or a dead one",
|
||||
c_src.units == (app_main.UNIT_A,)
|
||||
and c_src.live_units() == (app_main.UNIT_A,))
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("11. mutation: what defeats these guards, and which check bites")
|
||||
|
||||
@@ -791,17 +791,29 @@ check("the committed replay fixtures are present - a regression fixture CI "
|
||||
"cannot see is not a regression fixture", len(REPLAY) >= 2)
|
||||
|
||||
# ⚠️ `peak_cap_w:` appears TWICE in config.yaml - once under `options:` with the
|
||||
# default, once under `schema:` with `int(500,15000)`. Taking the last match
|
||||
# would blow up on the schema line, and taking any match that parses would be
|
||||
# luck; the FIRST is the options block, which is the number an install lands on.
|
||||
SHIPPED_CAP_W = None
|
||||
for line in (HERE / "config.yaml").read_text(encoding="utf-8").splitlines():
|
||||
if line.strip().startswith("peak_cap_w:"):
|
||||
try:
|
||||
SHIPPED_CAP_W = float(line.split(":", 1)[1].strip())
|
||||
except ValueError:
|
||||
continue
|
||||
break
|
||||
# default, once under `schema:` with `int(500,15000)`. This used to take the
|
||||
# FIRST match on a STRIPPED line and call that the options block; CFG-04 made
|
||||
# stripped-line-first-match unsafe in this file's neighbours (a `max_w:` nested
|
||||
# six spaces under `inverters:` in the schema block began outranking the
|
||||
# top-level one), so it is anchored the same way they now are: the options half
|
||||
# of the file, at exactly two spaces of indentation. `peak_cap_w` is not a
|
||||
# per-inverter key today and this reader was never wrong - it is the IDIOM that
|
||||
# was, and leaving one copy of it here would be leaving the next per-inverter
|
||||
# key a place to land. test_inverter.py part 12 runs this function against a
|
||||
# two-inverter config.
|
||||
def shipped_option(key):
|
||||
"""The `options:` default for `key`, anchored at two spaces. None if absent."""
|
||||
body = (HERE / "config.yaml").read_text(encoding="utf-8")
|
||||
for line in body[:body.index("\nschema:")].splitlines():
|
||||
if line.startswith(f" {key}:") and not line[2:3].isspace():
|
||||
try:
|
||||
return float(line.split(":", 1)[1].strip())
|
||||
except ValueError:
|
||||
return None
|
||||
return None
|
||||
|
||||
|
||||
SHIPPED_CAP_W = shipped_option("peak_cap_w")
|
||||
check("config.yaml's shipped peak_cap_w was read out of the file rather than "
|
||||
"typed here", SHIPPED_CAP_W is not None)
|
||||
|
||||
|
||||
@@ -19,8 +19,8 @@ import sys
|
||||
|
||||
from app.maintenance import MAINT_OPTION_DEFAULTS, MaintConfig
|
||||
from app.validate import (
|
||||
ACTUATOR_WRITE_KEYS, FIRMWARE_INGEST_VETO_S, ConfigRefused, refuse,
|
||||
validate_startup_config,
|
||||
ACTUATOR_WRITE_KEYS, FIRMWARE_INGEST_VETO_S, ConfigRefused,
|
||||
actuator_writers, refuse, validate_startup_config,
|
||||
)
|
||||
|
||||
fails = []
|
||||
@@ -135,9 +135,128 @@ for blank in ("", " ", None):
|
||||
check("...and the message says why it is dangerous rather than untidy",
|
||||
why(validate_startup_config(base(setpoint_entity=""), None, None),
|
||||
"heartbeat"))
|
||||
# specs §1.5: two writers on one actuator is not expressible in this schema.
|
||||
check("there is exactly one way to reach the actuator",
|
||||
ACTUATOR_WRITE_KEYS == ("setpoint_entity",))
|
||||
# --------------------------------------------------------------------------- #
|
||||
# specs §1.5: TWO WRITERS ON ONE ACTUATOR, AND WHAT ACTUALLY GRADES IT
|
||||
# --------------------------------------------------------------------------- #
|
||||
# ⚠️ WHAT USED TO BE HERE, AND WHY IT WAS NOT ENOUGH. This was one line:
|
||||
#
|
||||
# check("there is exactly one way to reach the actuator",
|
||||
# ACTUATOR_WRITE_KEYS == ("setpoint_entity",))
|
||||
#
|
||||
# and validate.py's comment said the §1.5 non-goal was ENFORCED by construction -
|
||||
# exactly one such key, so a second writer is not expressible in the options
|
||||
# schema at all. Both were true. Both graded THE SHAPE OF THE OPTIONS SCHEMA
|
||||
# rather than the writes, and the difference is not academic: the config below
|
||||
# has TWO WRITERS ON ONE ACTUATOR and leaves that tuple's length at 1. The check
|
||||
# stays green while the property it protects is gone, which is this repository's
|
||||
# named failure mode - a check that observes something other than what it claims
|
||||
# to observe.
|
||||
#
|
||||
# So the first thing this section does is DEMONSTRATE the old check passing on
|
||||
# the hazardous config, rather than assert in prose that it would have.
|
||||
_PER_INVERTER_HAZARD = base(inverters=[
|
||||
{"id": "inverter-a", "setpoint_entity": "number.goodwe_setpoint"},
|
||||
# ⚠️ INVERTER B DOES NOT EXIST. Nothing is measured from it here; it is a
|
||||
# config fixture, and the only thing that matters about it is that its
|
||||
# `setpoint_entity` NAMES THE SAME ENTITY as the scalar key above - which is
|
||||
# the shape of the mistake, and the shape CFG-04 makes reachable.
|
||||
{"id": "inverter-b", "setpoint_entity": "number.goodwe_setpoint"}])
|
||||
|
||||
check("⚠️ THE DEFECT, DEMONSTRATED: on a per-inverter config with two writers "
|
||||
"aimed at ONE entity, the old proxy is still green - it counts option "
|
||||
"KEYS, and there is still exactly one key called setpoint_entity. This "
|
||||
"is the check that could not see the thing it was named after",
|
||||
len(ACTUATOR_WRITE_KEYS) == 1)
|
||||
|
||||
_census = actuator_writers(_PER_INVERTER_HAZARD)
|
||||
print(f" the same config, censused by writer: "
|
||||
f"{ {k: len(v) for k, v in _census.items()} }")
|
||||
check("...and the replacement SEES it, because it counts writers per ACTUATOR "
|
||||
"rather than keys: three declarations, one entity",
|
||||
list(_census) == ["number.goodwe_setpoint"]
|
||||
and len(_census["number.goodwe_setpoint"]) == 3)
|
||||
_hazard_problems = validate_startup_config(_PER_INVERTER_HAZARD, -5000, 5000)
|
||||
check("AC 3: and the config is REFUSED, where today it starts",
|
||||
why(_hazard_problems, "one actuator"))
|
||||
check("...and the refusal names the actuator and every writer aimed at it, so "
|
||||
"an operator can see WHICH declarations to remove rather than being told "
|
||||
"only that something is wrong",
|
||||
why(_hazard_problems, "number.goodwe_setpoint")
|
||||
and why(_hazard_problems, "inverters[0].setpoint_entity")
|
||||
and why(_hazard_problems, "inverters[1].setpoint_entity"))
|
||||
|
||||
# ⚠️ AND THE GATE MUST NOT REFUSE THE CONFIG CFG-04 IS ACTUALLY FOR. A validator
|
||||
# that fires on the legitimate case gets switched off by the first person it
|
||||
# inconveniences, and then none of this is enforced. Two inverters with two
|
||||
# entities are two writers on TWO actuators, which is not the non-goal - it is
|
||||
# the whole point of the per-inverter roster.
|
||||
#
|
||||
# ⚠️ THE ENTRIES BELOW GAINED `name` AND `max_w` WHEN CFG-04 LANDED, AND THE
|
||||
# HAZARD FIXTURE ABOVE DELIBERATELY DID NOT. SAFETY-28 wrote both against a
|
||||
# shape that did not exist yet and guessed `id`; CFG-04 chose `name`, and made
|
||||
# `name`/`setpoint_entity`/`max_w` required of every entry (rule 9). The hazard
|
||||
# fixture is left in the OLD guessed shape on purpose - the claim it makes is
|
||||
# that `actuator_writers()` finds writers STRUCTURALLY, under a container and a
|
||||
# key spelling this file was never told, and rewriting it into today's shape
|
||||
# would quietly turn it into a check that the census knows about `inverters`.
|
||||
# This one is the opposite claim - that a real, valid, two-inverter config is
|
||||
# ACCEPTED - so it has to be a config the shipped validator actually accepts.
|
||||
_PER_INVERTER_OK = {k: v for k, v in base().items() if k != "setpoint_entity"}
|
||||
_PER_INVERTER_OK["inverters"] = [
|
||||
{"name": "inverter-a", "setpoint_entity": "number.goodwe_setpoint",
|
||||
"max_w": 2000},
|
||||
# ⚠️ INVERTER B DOES NOT EXIST. 2000 W here is the SHIPPED default repeated,
|
||||
# not a rating measured off a second device - SPIKE-04 measures that when
|
||||
# there is one to measure. Nothing in this file depends on the number.
|
||||
{"name": "inverter-b", "setpoint_entity": "number.goodwe_setpoint_b",
|
||||
"max_w": 2000}]
|
||||
check("two inverters with their own entities are ACCEPTED - one writer each, "
|
||||
"no shared actuator, and that is CFG-04's whole purpose",
|
||||
validate_startup_config(_PER_INVERTER_OK, -5000, 5000) == [])
|
||||
check("...and today's single-inverter config is untouched: one writer, one "
|
||||
"actuator, and the census finds it wherever it is declared",
|
||||
validate_startup_config(base(), -5000, 5000) == []
|
||||
and actuator_writers(base()) ==
|
||||
{"number.goodwe_setpoint": ["setpoint_entity"]})
|
||||
|
||||
# The census is found STRUCTURALLY, not by looking for a container called
|
||||
# `inverters` - CFG-04 has not chosen that name yet, and a census that guessed
|
||||
# wrong would go green while two writers existed, which is the same defect one
|
||||
# step along.
|
||||
check("a writer nested under a container this file has never heard of is "
|
||||
"still counted, because the walk is over the options TREE and not over a "
|
||||
"list of blessed key names",
|
||||
len(actuator_writers({"setpoint_entity": "number.x",
|
||||
"whatever_cfg04_calls_it": {
|
||||
"unit_b": {"setpoint_entity": "NUMBER.X"}}})
|
||||
["number.x"]) == 2)
|
||||
check("...and entity ids are folded to lower case, so a second writer cannot "
|
||||
"be smuggled past the census on Number.X versus number.x",
|
||||
why(validate_startup_config(base(inverters=[{"setpoint_entity":
|
||||
"NUMBER.GOODWE_SETPOINT"}]),
|
||||
-5000, 5000), "one actuator"))
|
||||
# ⚠️ THIS CHECK CHANGED SHAPE IN CFG-04, AND THE REASON IS A DECISION RATHER
|
||||
# THAN AN ADJUSTMENT. It used to assert that a blank per-inverter entity left
|
||||
# the whole config ACCEPTED - "blank is how an operator leaves a slot
|
||||
# unconfigured". CFG-04 decided that is not true of a ROSTER ENTRY: an entry
|
||||
# with no `setpoint_entity` is a unit that `allocator.plan()` still gives a
|
||||
# share of the site target to and that nothing can command, on a status page
|
||||
# reporting a site at full strength. Rule 9 refuses it by name. The claim about
|
||||
# the CENSUS is untouched and is now asserted directly on the census, where it
|
||||
# always belonged - a blank contributes no writer, so it cannot manufacture a
|
||||
# two-writer refusal out of two unconfigured slots.
|
||||
check("a BLANK per-inverter entity is not a writer - the same rule the scalar "
|
||||
"key gets, since write_setpoint() returns immediately on a blank entity",
|
||||
actuator_writers(base(inverters=[{"setpoint_entity": " "},
|
||||
{"setpoint_entity": ""}]))
|
||||
== {"number.goodwe_setpoint": ["setpoint_entity"]})
|
||||
check("...but the ENTRY is refused all the same, by rule 9 and not by the "
|
||||
"census: a roster slot nothing can write still takes a share of the site "
|
||||
"target every cycle and delivers none of it",
|
||||
why(validate_startup_config(base(inverters=[{"name": "inverter-b",
|
||||
"max_w": 2000,
|
||||
"setpoint_entity": " "}]),
|
||||
-5000, 5000), "has no setpoint_entity"))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("3. a meter that can never read")
|
||||
@@ -234,6 +353,64 @@ check("...and it is refused with maintenance_enabled off, as shipped",
|
||||
base(max_w=2000, maintenance_charge_w=2500,
|
||||
maintenance_enabled=False), -5000, 5000), "THE CEILING WINS"))
|
||||
|
||||
# ⚠️ MAINT-05: AND AT TWO PACKS IT IS THE WEAKEST CAP, NOT THE FIRST ENTRY'S.
|
||||
# The comment this replaces in validate.py said, in as many words, that it took
|
||||
# the FIRST unit's cap because there was exactly one `Maintenance` and it could
|
||||
# only ever recalibrate `inverters[0]` - and that "when `maint_unit` stops being
|
||||
# `inverters[0]`, this line moves with it". It has. Every pack is now
|
||||
# recalibrated on its own schedule, so the shaping claim can be filed on any of
|
||||
# them and the cap that contradicts it first is the smallest.
|
||||
#
|
||||
# ⚠️ THE FIXTURE'S TWO CAPS ARE DELIBERATELY DIFFERENT AND THE RATE SITS
|
||||
# BETWEEN THEM. Two equal caps could not tell "grades the first" from "grades
|
||||
# the smallest", and a rate above both would be refused by either rule - so
|
||||
# 3000 W against caps of 5000 W and 2000 W is the one arrangement where the old
|
||||
# answer and the new one disagree. ⚠️ 2000 W for the second pack is a
|
||||
# HYPOTHESIS: inverter B does not physically exist and nothing here is measured
|
||||
# from one.
|
||||
def _roster(a_max, b_max, **over):
|
||||
o = base(**over)
|
||||
for k in ("setpoint_entity", "soc_entity", "batt_entity", "max_w"):
|
||||
o.pop(k, None)
|
||||
o["inverters"] = [
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a",
|
||||
soc_entity="sensor.soc_a", batt_entity="sensor.batt_a",
|
||||
max_w=a_max),
|
||||
dict(name="inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b",
|
||||
max_w=b_max)]
|
||||
return o
|
||||
|
||||
|
||||
_two = _roster(5000, 2000, maintenance_charge_w=3000, maintenance_discharge_w=1000,
|
||||
sign_disagree_w=300, unit_sign_disagree_w=300)
|
||||
_p_two = [p for p in validate_startup_config(_two, -5000, 5000)
|
||||
if "maintenance_charge_w" in p]
|
||||
print(f" 5000 W and 2000 W packs, charge 3000 W -> {_p_two}")
|
||||
check("⚠️ A CHARGE RATE THE SMALLEST PACK CANNOT TAKE IS REFUSED, even though "
|
||||
"the FIRST pack could. Before MAINT-05 the second pack was never "
|
||||
"recalibrated, so its cap could not contradict anything; it is now, and "
|
||||
"its cheap-window charge would ask for hi=-3000 against lo=-2000 - the "
|
||||
"`lo > hi` contradiction, 0 W, on the pack nobody was watching",
|
||||
len(_p_two) == 1 and why(_p_two, "max_w (inverter-b) is 2000 W"))
|
||||
check("...and the message names the pack the number came off, not the first "
|
||||
"entry - an operator told to lower a number on the wrong device is being "
|
||||
"sent to the wrong device by the message that exists to stop that",
|
||||
not why(_p_two, "max_w (inverter-a)"))
|
||||
check("...while the same rate against two packs that can both take it starts, "
|
||||
"so this is a comparison and not a blanket refusal of rosters",
|
||||
[p for p in validate_startup_config(
|
||||
_roster(5000, 4000, maintenance_charge_w=3000,
|
||||
maintenance_discharge_w=1000, sign_disagree_w=300,
|
||||
unit_sign_disagree_w=300), -5000, 5000)
|
||||
if "maintenance_charge_w" in p] == [])
|
||||
check("...and at a ROSTER OF ONE `min()` over one cap is that cap: the same "
|
||||
"message, the same boundary, the same refusal the flat config always got",
|
||||
why(validate_startup_config(base(max_w=2000, maintenance_charge_w=2500),
|
||||
-5000, 5000), "THE CEILING WINS")
|
||||
and validate_startup_config(base(max_w=2000, maintenance_charge_w=2000),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# ⚠️ THE SIBLING, CHECKED RATHER THAN ASSUMED. The shaping is NOT symmetric:
|
||||
# drain files Claim.set at P_MAINTENANCE and owns the actuator, so the ceiling
|
||||
# CLAMPS it (+2000 W) instead of contradicting it, and the arbiter's explain()
|
||||
@@ -404,9 +581,26 @@ check("...and the message explains it would read as a trip, not a mistake",
|
||||
# check below.
|
||||
check("the smallest sane max_w still starts",
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
unit_sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000) == [])
|
||||
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
|
||||
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
|
||||
# ⚠️ SAFETY-30 ADDED A SECOND WAY TO DISARM A SIGN WATCHDOG BY CONFIGURATION,
|
||||
# and the fixture above now has to name BOTH thresholds - which is the check
|
||||
# doing its job rather than a bookkeeping edit. `unit_sign_disagree_w` bounds a
|
||||
# unit's own SHARE, which the same `supervised` claim holds at +-max_w, so at or
|
||||
# above the ceiling it is unsatisfiable by construction exactly as
|
||||
# `sign_disagree_w` is. Refused even at the shipped roster of one, where this
|
||||
# watchdog is not armed: a config that cannot work is refused when it is
|
||||
# written, not on the day somebody adds a second inverter.
|
||||
check("...and the per-inverter threshold has the same rule, named separately "
|
||||
"so an operator is told WHICH watchdog they disarmed",
|
||||
why(validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000),
|
||||
"unit_sign_disagree_w"))
|
||||
check("...and one watt under that ceiling is reachable, so accepted",
|
||||
validate_startup_config(base(max_w=2000, unit_sign_disagree_w=1999),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("what must NOT be refused - a validator that fires on trivia gets deleted")
|
||||
|
||||
+1313
-11
File diff suppressed because it is too large
Load Diff
@@ -0,0 +1,292 @@
|
||||
#!/usr/bin/env python3
|
||||
"""ALLOC-01's acceptance evidence, on admin/goodwe's OWN two-master rig.
|
||||
|
||||
python3 tools/alloc_sim.py --table # broadcast vs allocator, side by side
|
||||
python3 tools/alloc_sim.py --splits # AC 2: split-invariance at the meter
|
||||
python3 tools/alloc_sim.py --sweep # AC 3: gain to 1.0 at every split
|
||||
python3 tools/alloc_sim.py --all
|
||||
|
||||
# DEV-02: the split-invariance finding ALLOC-01's review handed on, and the
|
||||
# sensing change that closed it. The two rows are the evidence.
|
||||
python3 tools/alloc_sim.py --splits --gain 0.4 --feedback unit # 250 W apart
|
||||
python3 tools/alloc_sim.py --splits --gain 0.4 --feedback site # identical
|
||||
|
||||
WHY THIS IS A SCRIPT AND NOT A `test_*.py`
|
||||
==========================================
|
||||
It needs admin/goodwe checked out beside this repository, and the add-on's CI
|
||||
job has no credentials for that repository - it is private and the job's token
|
||||
is minted for this one. A `test_*.py` here is globbed and RUN by
|
||||
.gitea/workflows/checks.yml, so a file that needs the sibling repo would either
|
||||
fail the gate or - worse, and this is what test_freeze.py does today - pass
|
||||
SILENTLY having checked nothing. So the rig evidence lives here, is quoted in
|
||||
the pull request, and test_alloc.py grades the same properties in CI against a
|
||||
plant it models itself and says it models.
|
||||
|
||||
WHAT IS REAL IN HERE
|
||||
====================
|
||||
Everything except the allocator's inputs. `sitesim.run_site()` is used
|
||||
UNMODIFIED: the add-on's own `compute()` closes the loop, the firmware's own
|
||||
encoder puts each command on each unit's wire, `plantsim.Plant` is the battery
|
||||
model, and `watchdog.SignWatchdog` is the shipped detector. The ONLY thing this
|
||||
file changes is `sitesim.allocate`, which it wraps so that a new mode name
|
||||
routes to `app.arbiter.allocate()` - the shipped allocator, imported, never
|
||||
transcribed - and delegates every other mode to the original. That wrapper is
|
||||
the whole diff between the RED run and the GREEN run, which is what makes the
|
||||
comparison worth anything.
|
||||
|
||||
⚠️ NOTHING IN admin/goodwe IS MODIFIED. `sim/` triggers a workflow that takes
|
||||
the physical rig's lock; this file reads that repository and writes nothing to
|
||||
it.
|
||||
|
||||
⚠️ INVERTER B'S PARAMETERS ARE PLACEHOLDERS. `plantsim.INVERTER_B` carries
|
||||
`measured=False` - it is A's numbers copied, because inverter B does not exist
|
||||
yet (SPIKE-04 measures it). Every verdict below that involves B is a verdict
|
||||
about the ARCHITECTURE, not about that inverter, and the runs say so.
|
||||
"""
|
||||
import argparse
|
||||
import math
|
||||
import os
|
||||
import pathlib
|
||||
import sys
|
||||
|
||||
HERE = pathlib.Path(__file__).resolve().parent
|
||||
ADDON = HERE.parent.parent # the goodwe-addon checkout root
|
||||
|
||||
|
||||
def find_sim():
|
||||
"""admin/goodwe's `sim/` directory, or None - and the caller says which.
|
||||
|
||||
$GOODWE_SIM first, the same override test_freeze.py takes, then the sibling
|
||||
checkouts that actually occur. A missing sibling is not a failure of the
|
||||
allocator and must never be reported as one.
|
||||
"""
|
||||
cands = []
|
||||
if os.environ.get("GOODWE_SIM"):
|
||||
cands.append(pathlib.Path(os.environ["GOODWE_SIM"]))
|
||||
for up in (ADDON.parent, ADDON.parent.parent):
|
||||
cands += [up / "goodwe" / "sim", up / "goodwe-session" / "goodwe" / "sim"]
|
||||
for c in cands:
|
||||
if (c / "sitesim.py").exists():
|
||||
return c
|
||||
return None
|
||||
|
||||
|
||||
def load(sim):
|
||||
"""Import the rig, pointed at THIS checkout, and graft our allocator in."""
|
||||
sys.path[:0] = [str(sim)]
|
||||
# inject.py resolves the add-on repo, and refuses to guess between two
|
||||
# checkouts. Naming it removes the guess: the tree under test is the tree
|
||||
# this file ships in, whatever else is lying around the disk.
|
||||
os.environ.setdefault("GOODWE_ADDON_REPO", str(ADDON))
|
||||
import inject, sitesim # noqa: E402
|
||||
arbiter = sitesim.load_addon("app.arbiter", "alloc_sim")
|
||||
allocator = sitesim.load_addon("app.allocator", "alloc_sim")
|
||||
|
||||
original = sitesim.allocate
|
||||
|
||||
def patched(target_w, n, mode):
|
||||
if not mode.startswith("alloc01"):
|
||||
return original(target_w, n, mode)
|
||||
# "alloc01" or "alloc01:90/10" - the weights, which AC 2 says must not
|
||||
# change the aggregate trace at the meter.
|
||||
names = [f"inverter-{c}" for c in "ab"[:n]]
|
||||
parts = mode.split(":", 1)
|
||||
if len(parts) == 2:
|
||||
ws = [float(x) for x in parts[1].split("/")]
|
||||
else:
|
||||
ws = [1.0] * n
|
||||
bounds = {u: arbiter.UnitBounds(lo=-r, hi=r)
|
||||
for u, r in zip(names, patched.ratings)}
|
||||
shares, ok = arbiter.allocate(
|
||||
target_w, bounds, weights=dict(zip(names, ws)))
|
||||
if not ok:
|
||||
# A refusal on this rig would be a bug in the experiment, not a
|
||||
# finding: nothing here is stale, mis-routed or pinned. Fail loud.
|
||||
raise SystemExit(f"alloc_sim: the allocator REFUSED at {target_w} W "
|
||||
"- no scenario below should reach a refusal")
|
||||
return [float(shares[u]) for u in names]
|
||||
|
||||
# The envelope handed to the allocator each tick: the rating each MODELLED
|
||||
# inverter actually carries, read off plantsim rather than typed here, so a
|
||||
# change to INVERTER_A - or a --b-rating override - moves the envelope with
|
||||
# it instead of leaving this file quietly wrong. ⚠️ INVERTER_B's IS A
|
||||
# PLACEHOLDER; nothing here has measured it.
|
||||
from plantsim import INVERTER_A, INVERTER_B
|
||||
patched.ratings = [INVERTER_A["rating_w"], INVERTER_B["rating_w"]]
|
||||
sitesim.allocate = patched
|
||||
return inject, sitesim, arbiter, allocator
|
||||
|
||||
|
||||
def run(sitesim, control, watchdog, mode, gain, **kw):
|
||||
return sitesim.run_site(control, watchdog, n=2, gain=gain, mode=mode,
|
||||
label=f"N=2 gain {gain} {mode}", **kw)
|
||||
|
||||
|
||||
def run_site_feedback(sitesim, control, mode, gain, load_w=2000.0, cycles=40,
|
||||
cycle_s=None, dt=0.05):
|
||||
"""`sitesim.run_site()` WITH EXACTLY ONE LINE CHANGED, and it is named here.
|
||||
|
||||
⚠️ THIS IS A COPY AND IT IS A COPY ON PURPOSE. `run_site` lives in
|
||||
admin/goodwe, which this file reads and never writes, and it feeds
|
||||
`compute()` ONE inverter's power as `actual_w` because that is what the
|
||||
add-on gave it: a single `batt_entity`, so an operator who wired up a second
|
||||
inverter had a loop that saw unit A only. A rig that fed the sum would have
|
||||
been KINDER than the deployment.
|
||||
|
||||
So this differs from `run_site` in one expression - `site.battery`, the
|
||||
site's total inverter power, instead of `inverters[0].plant.actual` - and in
|
||||
nothing else.
|
||||
|
||||
⚠️ AND SINCE DEV-02 THAT ONE EXPRESSION IS THE SHIPPED ONE, WHICH TURNS THIS
|
||||
FUNCTION FROM A COUNTERFACTUAL INTO THE MODEL. `Controller.site_batt_w` is
|
||||
the SUM of the per-instance battery readings and is what main.py hands
|
||||
`compute()`; `--feedback site` is therefore the add-on as it now stands, and
|
||||
`--feedback unit` is the PRE-DEV-02 sensing, kept because the comparison is
|
||||
the evidence. Measured here, 2 kW load, 40 cycles: fed one unit's power the
|
||||
aggregate trace at the meter is split-dependent by 510 W at gain 0.2, 250 W
|
||||
at 0.4 and 50 W at 0.6; fed the site total every split is bit-identical at
|
||||
every gain. `run_site` still models the old sensing and must not be
|
||||
"corrected" to the new one - the row it produces is what the fix is measured
|
||||
against.
|
||||
"""
|
||||
from plantsim import INVERTER_A, INVERTER_B, Inverter, Site
|
||||
cycle_s = sitesim.CYCLE_S if cycle_s is None else cycle_s
|
||||
specs = [("A", INVERTER_A), ("B", INVERTER_B)]
|
||||
inverters = [Inverter.from_spec(n, dict(sp, **sitesim.INSTANT))
|
||||
for n, sp in specs]
|
||||
site = Site(inverters, load=load_w)
|
||||
loop = sitesim.Loop(control, gain)
|
||||
samples = []
|
||||
for c in range(cycles):
|
||||
grid = site.grid
|
||||
d = loop.cycle(grid, site.battery) # <- THE ONE CHANGED LINE
|
||||
for inv, share in zip(inverters,
|
||||
sitesim.allocate(d.target_w, len(inverters), mode)):
|
||||
inv.command(share)
|
||||
site.settle(cycle_s, dt=dt)
|
||||
samples.append(dict(cycle=c, grid_before=grid, target=d.target_w,
|
||||
grid=site.grid, batt=site.battery, reason=d.reason,
|
||||
sat=d.sat_count, frozen=d.frozen, clamped=d.clamped,
|
||||
i_clamped=d.i_clamped,
|
||||
shares=[inv.plant.cmd for inv in inverters]))
|
||||
return sitesim.Run(f"site-feedback gain {gain} {mode}", samples, inverters,
|
||||
mode, gain, None)
|
||||
|
||||
|
||||
SPLITS = ["alloc01:50/50", "alloc01:90/10", "alloc01:10/90",
|
||||
"alloc01:99/1", "alloc01:1/0"]
|
||||
|
||||
|
||||
def table(sitesim, control, watchdog, cycles, load_w):
|
||||
print("=== AC 3 / the ARCH-01 experiment: broadcast vs allocation ===")
|
||||
print(f"{'run':28} {'tail p2p':>10} {'worst export':>13} commands")
|
||||
rows = []
|
||||
for gain in (0.6, 1.0):
|
||||
for mode in ["broadcast", "even_split"] + SPLITS:
|
||||
r = run(sitesim, control, watchdog, mode, gain,
|
||||
load_w=load_w, cycles=cycles)
|
||||
rows.append((gain, mode, r))
|
||||
print(f"gain {gain} {mode:20} {r.p2p():10.0f} "
|
||||
f"{r.worst_export(1):13.0f} "
|
||||
f"{[int(x) for x in r.targets(4)]}")
|
||||
return rows
|
||||
|
||||
|
||||
def splits(sitesim, control, watchdog, cycles, load_w, gain=1.0,
|
||||
feedback="unit"):
|
||||
"""AC 2. A 90/10 and a 50/50 split, and the AGGREGATE trace at the meter."""
|
||||
print(f"=== AC 2 / split-invariance at gain {gain}, loop feedback "
|
||||
f"= {feedback} ===")
|
||||
base = None
|
||||
ok = True
|
||||
for mode in SPLITS:
|
||||
r = (run(sitesim, control, watchdog, mode, gain,
|
||||
load_w=load_w, cycles=cycles) if feedback == "unit"
|
||||
else run_site_feedback(sitesim, control, mode, gain,
|
||||
load_w=load_w, cycles=cycles))
|
||||
trace = [round(g, 6) for g in r.grids()]
|
||||
cmds = [round(t, 6) for t in r.targets()]
|
||||
if base is None:
|
||||
base, base_mode = trace, mode
|
||||
print(f" {mode:16} reference: grid {[int(g) for g in trace[:6]]} ...")
|
||||
else:
|
||||
same = trace == base
|
||||
ok &= same
|
||||
print(f" {mode:16} {'IDENTICAL' if same else 'DIFFERS'} to "
|
||||
f"{base_mode} worst |delta| "
|
||||
f"{max(abs(a - b) for a, b in zip(trace, base)):.6f} W")
|
||||
# And the shares are NOT the same - otherwise the invariance is vacuous.
|
||||
s = r.samples[-1]["shares"]
|
||||
print(f" last shares {[int(x) for x in s]}, "
|
||||
f"sum {sum(s):.0f} vs site command {cmds[-1]:.0f}")
|
||||
print(f" -> split-invariance {'HOLDS' if ok else 'FAILS'}")
|
||||
return ok
|
||||
|
||||
|
||||
def sweep(sitesim, control, watchdog, cycles, load_w):
|
||||
"""AC 3. Gain swept to config.yaml's documented maximum, at every split."""
|
||||
print("=== AC 3 / gain sweep to 1.0 at every split ===")
|
||||
gains = [0.05, 0.2, 0.4, 0.6, 0.8, 0.9, 1.0]
|
||||
print(f"{'mode':20}" + "".join(f"{g:>9}" for g in gains))
|
||||
worst = {}
|
||||
for mode in ["broadcast"] + SPLITS:
|
||||
line = f"{mode:20}"
|
||||
for g in gains:
|
||||
r = run(sitesim, control, watchdog, mode, g,
|
||||
load_w=load_w, cycles=cycles)
|
||||
p = r.p2p()
|
||||
worst[mode] = max(worst.get(mode, 0.0), p)
|
||||
line += f"{p:9.0f}"
|
||||
print(line + f" worst {worst[mode]:.0f} W p2p")
|
||||
print(" (tail peak-to-peak grid swing, W. A limit cycle is a tail that "
|
||||
"does not go to zero.)")
|
||||
return worst
|
||||
|
||||
|
||||
def main():
|
||||
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
|
||||
ap.add_argument("--table", action="store_true")
|
||||
ap.add_argument("--splits", action="store_true")
|
||||
ap.add_argument("--sweep", action="store_true")
|
||||
ap.add_argument("--all", action="store_true")
|
||||
ap.add_argument("--cycles", type=int, default=40)
|
||||
ap.add_argument("--load", type=float, default=2000.0)
|
||||
ap.add_argument("--gain", type=float, default=1.0)
|
||||
ap.add_argument("--feedback", choices=("unit", "site"),
|
||||
default="site",
|
||||
help="what the loop is fed as actual_w: the site total "
|
||||
"(the shipped add-on since DEV-02, the default here) "
|
||||
"or one inverter's power (the PRE-DEV-02 sensing, "
|
||||
"kept because the comparison is the evidence)")
|
||||
a = ap.parse_args()
|
||||
if not (a.table or a.splits or a.sweep):
|
||||
a.all = True
|
||||
|
||||
sim = find_sim()
|
||||
if sim is None:
|
||||
print("alloc_sim: admin/goodwe is not checked out beside this "
|
||||
"repository, so the two-master rig is unavailable. NOTHING has "
|
||||
"been measured. Set $GOODWE_SIM to its sim/ directory.")
|
||||
return 2
|
||||
print(f"rig: {sim}")
|
||||
inject, sitesim, arbiter, allocator = load(sim)
|
||||
control = sitesim.load_addon("app.control", "alloc_sim")
|
||||
watchdog = sitesim.load_addon("app.watchdog", "alloc_sim")
|
||||
print(f"add-on under test: {os.environ['GOODWE_ADDON_REPO']}")
|
||||
print("⚠️ inverter B's rating/ramp/lag are PLACEHOLDERS (plantsim."
|
||||
"INVERTER_B, measured=False) - SPIKE-04 measures them\n")
|
||||
|
||||
if a.table or a.all:
|
||||
table(sitesim, control, watchdog, a.cycles, a.load)
|
||||
print()
|
||||
if a.splits or a.all:
|
||||
splits(sitesim, control, watchdog, a.cycles, a.load, a.gain,
|
||||
a.feedback)
|
||||
print()
|
||||
if a.sweep or a.all:
|
||||
sweep(sitesim, control, watchdog, a.cycles, a.load)
|
||||
return 0
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
sys.exit(main())
|
||||
@@ -0,0 +1,210 @@
|
||||
"""CFG-04: does Supervisor accept a list-of-objects option? MEASURED, not assumed.
|
||||
|
||||
⚠️ WHY THIS SCRIPT EXISTS AND WHY IT IS COMMITTED. config.yaml had no
|
||||
list-of-objects option anywhere before CFG-04, and `static_profile` carries a
|
||||
structured value as a JSON STRING in a `str?` precisely because nobody knew
|
||||
whether the Supervisor's options validator supported a nested one. That is a
|
||||
question about a specific version of a specific piece of somebody else's
|
||||
software, and the honest way to answer it is to run that software.
|
||||
|
||||
WHAT IT RUNS. Supervisor's OWN `AppOptions` validator and its OWN
|
||||
`SCHEMA_APP_CONFIG`, out of the release image, against THIS repository's
|
||||
config.yaml. Nothing here is a re-implementation of the validation rules; if
|
||||
Supervisor changes them, this script changes its answer.
|
||||
|
||||
HOW TO RUN IT (the version is the one `ha info` reports on the target install -
|
||||
2026.08.0 is what 192.168.2.158 ran when CFG-04 landed):
|
||||
|
||||
docker run --rm \
|
||||
-v "$PWD:/w:ro" -v "$PWD/tools:/probe:ro" -v /tmp/out:/out \
|
||||
--entrypoint python3 \
|
||||
ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0 \
|
||||
/probe/supervisor_shape_probe.py
|
||||
|
||||
⚠️ IT TOUCHES NOTHING. It reads config.yaml and runs a validator in a throwaway
|
||||
container. It does not talk to the live Supervisor, does not POST options and
|
||||
does not install anything - the schema conflict in docs/deploy-rollback.md §4 is
|
||||
exactly what you do NOT want to discover on a running site.
|
||||
|
||||
WHAT IT ANSWERED, 2026-09-04, on 2026.08.0 - the full output is in
|
||||
DECISIONS/CFG-04-inverter-roster.md:
|
||||
|
||||
A. The manifest, list-of-objects schema and all, is ACCEPTED.
|
||||
B. The shipped `options:` block validates as it stands, and the SAME block
|
||||
with ONLY `inverters` removed is refused BY NAME - `Missing option
|
||||
'inverters' in root`. That is the one measurement the `inverters: []`
|
||||
default rests on, and it is an ISOLATED counterfactual: exactly one key
|
||||
varies between the two runs, so the refusal cannot be about anything else.
|
||||
B2. A reconstructed pre-0.6.0 options blob, merged with those defaults,
|
||||
validates. Its RAW form is refused - but for whichever required key the
|
||||
reconstruction happens to lack FIRST, which is an artefact of the
|
||||
reconstruction and NOT evidence about `inverters`. B is that evidence.
|
||||
C. A two-inverter blob validates, per-entry types enforced.
|
||||
D. An entry missing `name`, `setpoint_entity` or `max_w` is refused BY NAME,
|
||||
and a JSON string where the list belongs is refused outright.
|
||||
"""
|
||||
import sys, json, copy
|
||||
sys.path.insert(0, "/usr/src/supervisor")
|
||||
import voluptuous as vol
|
||||
from voluptuous.humanize import humanize_error
|
||||
from deepmerge import Merger
|
||||
from supervisor.apps.validate import SCHEMA_APP_CONFIG
|
||||
from supervisor.apps.options import AppOptions
|
||||
from pathlib import Path
|
||||
from supervisor.utils.yaml import read_yaml_file
|
||||
|
||||
MERGER = Merger(type_strategies=[(dict, ["merge"])],
|
||||
fallback_strategies=["override"], type_conflict_strategies=["override"])
|
||||
|
||||
raw = read_yaml_file(Path("/w/config.yaml"))
|
||||
print("== A. the whole config.yaml through SCHEMA_APP_CONFIG ==")
|
||||
try:
|
||||
cfg = SCHEMA_APP_CONFIG(raw)
|
||||
print(" PASS Supervisor accepts the add-on manifest, version", cfg["version"])
|
||||
except vol.Invalid as e:
|
||||
print(" FAIL ", humanize_error(raw, e)); sys.exit(1)
|
||||
|
||||
schema, defaults = cfg["schema"], cfg["options"]
|
||||
print(" schema declares", len(schema), "keys; inverters ->", json.dumps(schema["inverters"]))
|
||||
# .get, not [], deliberately: if someone deletes the `inverters: []` default
|
||||
# this line must not crash the probe before section B gets to REFUSE it.
|
||||
print(" options ship inverters ->", json.dumps(defaults.get("inverters")))
|
||||
|
||||
def validate(options):
|
||||
v = vol.Schema(vol.All(dict, AppOptions(None, schema, cfg["name"], "local_goodwe_controller")))
|
||||
try:
|
||||
return True, v(copy.deepcopy(options))
|
||||
except vol.Invalid as e:
|
||||
return False, str(e)
|
||||
|
||||
FAILED = []
|
||||
|
||||
def show(t, ok, d=""):
|
||||
print(f" {'PASS' if ok else 'FAIL'} {t}")
|
||||
if d: print(" " + str(d)[:300])
|
||||
if not ok: FAILED.append(t)
|
||||
|
||||
# The live install's persisted options, reconstructed from HANDOVER.md §1 and
|
||||
# docs/deploy-rollback.md §0/§B.5. No `inverters` key: it did not exist.
|
||||
LIVE = {
|
||||
"meter_entity": "sensor.p1_meter_active_power", "meter_invert": False,
|
||||
"soc_entity": "sensor.goodwe_battery_soc", "batt_entity": "sensor.goodwe_battery_power",
|
||||
"batt_invert": False,
|
||||
"setpoint_entity": "number.kelder_goodwe_master_stage1_goodwe_setpoint_w",
|
||||
"meter_source": "homewizard_local", "meter_phases": 1, "meter_max_age_s": 30,
|
||||
"meter_poll_s": 5, "p1_host": "192.168.2.250",
|
||||
"max_w": 5000, "gain": 0.6, "slew_w": 1000, "deadband_w": 15, "target_grid_w": -10,
|
||||
"step_w": 10, "saturation_w": 500, "saturation_cycles": 3, "integrator_max_w": 0,
|
||||
"heartbeat_s": 10, "stale_input_s": 15, "cycle_floor_s": 15, "auto_start": False,
|
||||
"maintenance_enabled": False, "estop_fitted": True, "log_level": "info",
|
||||
}
|
||||
|
||||
print("\n== B. THE LOAD-BEARING ONE: an options blob with no `inverters` key ==")
|
||||
# ⚠️ THIS IS AN ISOLATED COUNTERFACTUAL AND IT HAS TO STAY ISOLATED. The claim
|
||||
# the `inverters: []` default rests on is about ONE key, so exactly ONE key
|
||||
# varies between these two runs: the full shipped `options:` block, and the same
|
||||
# block with `inverters` removed and nothing else touched. Feeding the validator
|
||||
# some other, INCOMPLETE blob would also produce a refusal - but about whichever
|
||||
# required key that blob lacks first, which is a different measurement wearing
|
||||
# this one's label. §B2 below is that other blob, and it is labelled as such.
|
||||
ok, out = validate(dict(defaults))
|
||||
show("the shipped `options:` block validates AS IT STANDS - so anything refused "
|
||||
"on the next line is refused for the one key that was removed", ok,
|
||||
"" if ok else out)
|
||||
_no_inv = {k: v for k, v in defaults.items() if k != "inverters"}
|
||||
ok_ni, out_ni = validate(_no_inv)
|
||||
# ⚠️ THE ASSERTION IS ON THE KEY NAME, NOT ON `not ok`, AND THAT IS THE POINT.
|
||||
# A refusal is only evidence for THIS key if it NAMES this key. Asserted as a
|
||||
# bare `not ok`, this line would go on printing PASS after someone deleted
|
||||
# `inverters: []` from config.yaml - blind to the exact regression it is the
|
||||
# committed evidence for. Asserted on the string, it goes red: with the default
|
||||
# gone the line above fails too, because then nothing distinguishes the two runs.
|
||||
_names_it = (not ok_ni) and "Missing option 'inverters' in root" in str(out_ni)
|
||||
show("...and the SAME block with ONLY `inverters` removed is REFUSED, BY NAME - "
|
||||
"which is every options blob written before 0.6.0, since the key did not "
|
||||
"exist when they were written", _names_it, out_ni)
|
||||
|
||||
print("\n== B2. AC3: a reconstructed pre-0.6.0 blob upgrades into this version ==")
|
||||
# ⚠️ WHAT THIS SECTION IS AND IS NOT. LIVE is an INCOMPLETE reconstruction - it
|
||||
# carries the keys HANDOVER.md and deploy-rollback.md record and no others, so
|
||||
# it is missing many required keys that have nothing to do with this card. Its
|
||||
# raw refusal is therefore about whichever of THOSE the validator reaches first
|
||||
# (it has printed `meter_freeze_s` and `p1_phase_export_entities` on different
|
||||
# runs), NOT about `inverters`. It is kept because the MERGED half is a real
|
||||
# demonstration that `deepmerge(options:, stored)` is what App.options is; the
|
||||
# raw half is printed only so the merge has something to be contrasted with.
|
||||
# The `inverters` measurement is §B, where one key and only one key varies.
|
||||
ok, out = validate(LIVE)
|
||||
show("the reconstructed raw blob is REFUSED - for an unrelated missing key, "
|
||||
"because the reconstruction is incomplete; see the refusal printed below "
|
||||
"and §B for the `inverters` measurement", not ok, out)
|
||||
merged = MERGER.merge(copy.deepcopy(defaults), copy.deepcopy(LIVE))
|
||||
ok, out = validate(merged)
|
||||
show("the same blob MERGED with these defaults - what App.options actually is", ok,
|
||||
f"inverters={out.get('inverters')!r} setpoint_entity={out.get('setpoint_entity')!r} "
|
||||
f"max_w={out.get('max_w')!r}" if ok else out)
|
||||
|
||||
print("\n== C. AC2: a two-inverter blob an operator would POST ==")
|
||||
TWO = dict(LIVE, setpoint_entity="", inverters=[
|
||||
{"name": "inverter-a", "setpoint_entity": "number.goodwe_a_setpoint_w",
|
||||
"soc_entity": "sensor.goodwe_a_soc", "batt_entity": "sensor.goodwe_a_battery_power",
|
||||
"max_w": 5000},
|
||||
{"name": "inverter-b", "setpoint_entity": "number.goodwe_b_setpoint_w",
|
||||
"soc_entity": "sensor.goodwe_b_soc", "batt_entity": "sensor.goodwe_b_battery_power",
|
||||
"max_w": 3000}])
|
||||
ok, out = validate(MERGER.merge(copy.deepcopy(defaults), copy.deepcopy(TWO)))
|
||||
show("two inverters", ok, json.dumps(out.get("inverters")) if ok else out)
|
||||
# The validated blob, for anyone who wants to POST it. Optional: the probe's
|
||||
# whole job is the verdicts above, and a missing /out must not fail it.
|
||||
try:
|
||||
json.dump(out if ok else {}, open("/out/two_inverter_options.json", "w"), indent=1)
|
||||
except OSError:
|
||||
pass
|
||||
|
||||
print("\n== D. what the schema itself refuses, per entry ==")
|
||||
for title, entry in (
|
||||
("no name", {"setpoint_entity": "number.b", "max_w": 3000}),
|
||||
("no setpoint_entity", {"name": "inverter-b", "max_w": 3000}),
|
||||
("no max_w", {"name": "inverter-b", "setpoint_entity": "number.b"}),
|
||||
("max_w over the range", {"name": "inverter-b", "setpoint_entity": "number.b", "max_w": 9999})):
|
||||
ok, out = validate(dict(TWO, inverters=[entry]))
|
||||
show(f"an entry with {title} is refused", not ok, out)
|
||||
ok, out = validate(dict(TWO, inverters="[]"))
|
||||
show("a JSON STRING where the list belongs is refused", not ok, out)
|
||||
|
||||
|
||||
print("\n== E. the ROLLBACK direction, and the operator's UI ==")
|
||||
# The old (flat) schema, i.e. what an operator would be running after a
|
||||
# downgrade, meeting options that carry an `inverters` list.
|
||||
_flat_schema = {k: v for k, v in schema.items() if k != "inverters"}
|
||||
_v = vol.Schema(vol.All(dict, AppOptions(None, _flat_schema, cfg["name"],
|
||||
"local_goodwe_controller")))
|
||||
try:
|
||||
_rolled = _v(MERGER.merge(copy.deepcopy(defaults), copy.deepcopy(TWO)))
|
||||
show("a schema WITHOUT `inverters` drops the key with a warning rather "
|
||||
"than refusing - so a downgrade is not the §B trap in reverse",
|
||||
"inverters" not in _rolled, sorted(_rolled)[:6])
|
||||
except vol.Invalid as e:
|
||||
show("a schema WITHOUT `inverters` drops the key", False, str(e))
|
||||
|
||||
from supervisor.apps.options import UiOptions # noqa: E402
|
||||
try:
|
||||
_ui = [e for e in UiOptions(None)(schema) if e.get("name") == "inverters"]
|
||||
show("Supervisor's UI renderer turns it into a repeatable section rather "
|
||||
"than choking - an operator can add the second inverter in the "
|
||||
"Configuration tab, which the JSON-string alternative could not offer",
|
||||
bool(_ui) and _ui[0].get("multiple") is True, json.dumps(_ui))
|
||||
except Exception as e: # noqa: BLE001
|
||||
show("Supervisor's UI renderer survives the shape", False, f"{type(e).__name__}: {e}")
|
||||
|
||||
|
||||
# ⚠️ THE EXIT CODE IS PART OF THE INSTRUMENT. Without it the probe prints FAIL
|
||||
# and still succeeds, and a transcript is only evidence if a wrong answer is
|
||||
# distinguishable from a right one by something other than reading it.
|
||||
print()
|
||||
if FAILED:
|
||||
print(f"== {len(FAILED)} CASE(S) FAILED ==")
|
||||
for t in FAILED:
|
||||
print(" - " + t)
|
||||
sys.exit(1)
|
||||
print("== all cases passed ==")
|
||||
Reference in New Issue
Block a user