Commit Graph
100 Commits
Author SHA1 Message Date
glenn schrooyenandClaude 7a392a5367 UX-46: Dutch status rows, banners, notes and wizard lines on the NL pages
Rows and banners are built once with their Dutch beside them (messages.Bi)
and status_payload() picks one by the page's language. Settings notes and the
wizard's checks carry a Dutch twin (Note.nl) that /config/validate picks by
the posted language. The peak forecast label drops "(W)" in EN and NL.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-22 03:21:41 +02:00
glenn schrooyenandClaude Opus 5.5 24f31a9c3a SAFETY-121 review: DECISIONS limits state the jitter spread and the slow-cycle case
checks / unit (pull_request) Successful in 44m29s
infra-pin / fresh (pull_request) Successful in 1s
The jittery-meter numbers depend on the draw (review: 4, 4, 5 of 11 at the
quarter edge; up to 4 quiet quarters at 20 s; first warning up to 61 min
later). Above about 40 s per cycle, a short bound can still use up the
budget when the wire changes hands every few cycles. Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 11:55:24 +02:00
glenn schrooyenandClaude 8bf25696cb SAFETY-121: a recurring overload warns every quarter
checks / unit (pull_request) Successful in 44m51s
infra-pin / fresh (pull_request) Successful in 1s
TEST-23 F-1: on a 5 s meter a steady overload warned once in 70 min. The
loop was at its bound 4-5 cycles a quarter, all inside SAFETY-119's settle
of 12 cycles (60 s) and under its budget of 8 per 900 s. The simulation
fed the meter a cycle behind the battery reading, so the guard and the
charge chased each other and gave ~20 bound cycles a quarter.

The settle is now 4 cycles and 22 s (HANDBACK_CYCLES, SHORT_SPAN_S), and
the rolling budget one number, 11 per 900 s, at every cycle length. The
cycle length is no longer tracked. Commands unchanged; the re-pinned
digests of test_safety84/87 differ from bee7431 in OUTPUT_CLAMP rows only.
test_safety119 runs the rig's shape (meter in the same cycle) at 1-15 s
and checks a stop keeps the budget (review F2, X3).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-21 10:09:14 +02:00
glenn schrooyenandClaude Opus 5.5 96375ecbec SAFETY-119 review: DECISIONS states the steady-meter limit
checks / unit (pull_request) Successful in 43m33s
infra-pin / fresh (pull_request) Successful in 2s
The quarter-edge numbers were measured with one cycle per reading at a
steady interval. With the default 15 s cycle floor, a meter that is
sometimes slower adds cycles on an old reading and the false alarm can
come back (reviewer's runs, 11 seeds). Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 02:47:27 +02:00
glenn schrooyenandClaude 6fd0fa05f1 SAFETY-119 round 3c: the hidden-bound budget follows the cycle length
checks / unit (pull_request) Successful in 43m29s
infra-pin / fresh (pull_request) Successful in 1s
No single rolling budget met both cases in the sweep (8 false-alarmed on
2 s seed 25 and warned in 1 to 3 of 7 quarters at 15 s). The budget is
now 10 cycles up to a 3.5 s cycle, 8 up to 11 s, 6 up to 16 s, 4 beyond,
per rolling 15 minutes; 8 while the cycle length is unknown. A stop or a
gap over two minutes is not a cycle length. The unsourced "owner
accepted N=8" paragraph is removed from DECISIONS. test_safety119 part 4
now runs 2 s seed 25 and shows a fixed budget of 8 warns there; the
never case runs at 2 s and checks every other quarter at 15 s.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-21 00:57:43 +02:00
glenn schrooyenandClaude e27e62ff72 SAFETY-119 round 3b: no-clock budget, fixed-seed tests, accepted limits
checks / unit (pull_request) Successful in 43m1s
infra-pin / fresh (pull_request) Successful in 1s
The rolling budget now holds without a monotonic clock (it never refills).
Quarter-edge tests use seeds 1-3 at 2, 5, 10 and 15 s (no hand-picked seeds).
Re-pin comments point at part 6. DECISIONS lists the limits the owner
accepted with N=8 on 2026-10-20.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 20:46:14 +02:00
glenn schrooyenandClaude 86b94bedb5 SAFETY-119 round 3: DECISIONS table ranges over all runs
checks / unit (pull_request) Successful in 42m30s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 17:28:22 +02:00
glenn schrooyenandClaude 103db2fcda SAFETY-119 round 3: rolling 15-minute budget for the hidden integrator bound
checks / unit (pull_request) Successful in 42m33s
infra-pin / fresh (pull_request) Successful in 2s
At most 8 hidden bound cycles in any 900 s across all hand-backs, replacing
the per-run budget. Chosen from a sweep (N 3 to 10, 1 to 15 s meters, both
cases); DECISIONS has the table. Tests: never case at 5, 10, 15 s, quarter
edge at 2, 10, 15 s, the rolling budget at its boundaries.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 17:27:43 +02:00
glenn schrooyenandClaude 85542e443b SAFETY-119 round 2: test_safety119 reads through named_absence
checks / unit (pull_request) Successful in 42m22s
infra-pin / fresh (pull_request) Successful in 1s
test_named_absence flagged two unguarded reads (next() without a default,
a list indexed in a check name). Use first(), nth() and present().

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 01:38:24 +02:00
glenn schrooyenandClaude e76c70ecb0 SAFETY-119 round 2: one settle window per run of hand-backs
checks / unit (pull_request) Failing after 42m32s
infra-pin / fresh (pull_request) Successful in 2s
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-20 00:52:24 +02:00
glenn schrooyenandClaude Opus 5.5 b9ff6acea4 SAFETY-119 review: DECISIONS, at least once a quarter
checks / unit (pull_request) Successful in 42m1s
infra-pin / fresh (pull_request) Successful in 1s
A bigger house warns more often (every 150 s at 7.4 kW), so 'about' was
wrong. Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-19 20:29:00 +02:00
glenn schrooyenandClaude Opus 5.5 98026f9a46 SAFETY-119 review: DECISIONS states the worst delay and the no-warn case
checks / unit (pull_request) Successful in 42m3s
infra-pin / fresh (pull_request) Successful in 1s
The delay is 11 cycles, so up to 11 min at a 60 s cycle. A loop that loses
the wire again within 11 cycles is never counted; review measured one such
case (N=2, cheap-window charge, no forecast, house just over the rating).
The over-rating rule applies on cycles the loop decided. Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-19 20:17:08 +02:00
glenn schrooyenandClaude b0c2e5977d SAFETY-119: re-pin test_safety84/87 digests (log only); prove it
checks / unit (pull_request) Successful in 41m47s
infra-pin / fresh (pull_request) Successful in 1s
The re-pinned digests differ only in OUTPUT_CLAMP log rows; every command
and claim is the same as without the fix (test_safety119.py part 5).
DECISIONS: the delay at a 5 s meter and the open swap case.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 15:30:18 +02:00
glenn schrooyenandClaude c4e15ec4cd SAFETY-119: no "not keeping up" when the loop takes the wire back
When the peak guard or a maintenance charge hands the wire back, the loop's
integrator is re-seeded from that owner's command and kicked by a meter that
does not show it yet. It crossed its rail for a cycle or two and raised
goodwe_integrator_bound while the battery gave what it was told.

The loop's integrator bound is not counted until the plant's settle
(SHORT_CYCLES, SHORT_SPAN_S) has passed since the hand-back. An over-rating
always counts; a bound that lasts warns after the settle. No command
changes and no text changes. test_safety119.py; DECISIONS entry.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 14:14:08 +02:00
glenn schrooyenandClaude eb8375157d UX-45: count priced hours in the wizard, fill chart holes by the add-on's cover rule, mark only for price-mode batteries
checks / unit (pull_request) Successful in 40m20s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 10:01:58 +02:00
glenn schrooyenandClaude 17c6048417 UX-45: Home price chart draws one bar per price step the add-on uses
checks / unit (pull_request) Successful in 40m15s
infra-pin / fresh (pull_request) Successful in 1s
With 15-minute prices the chart now has one bar per quarter (92/96/100),
not hour averages; hourly and static tariffs still draw one bar per hour.
Cheap and dear marks come from the kept priceruns result (battery modes
on) or the arbitrage verdict's two points (off), not a thirds split.
A missing quarter is an empty bar. Removes plan.average_tip (EN/NL).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-19 00:35:29 +02:00
glenn schrooyenandClaude Opus 5.5 a4a7ff695e DOC-8 review: say the field guide PDF is rebuilt, still v0.1.0
checks / unit (pull_request) Successful in 40m29s
infra-pin / fresh (pull_request) Successful in 1s
README and FIELD-GUIDE.md said the PDF was not rebuilt; it was, on
2026-10-17. Its content is still v0.1.0 and outdated. Rewrap the
DOCS.md intro line. Text only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-17 03:27:35 +02:00
glenn schrooyenandClaude b8b357b552 DOC-8: update test_mqtt digest pins for the new manufacturer string
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 40m23s
Both digests hash the discovery payloads, which carry the manufacturer.
Values regenerated; nothing else changes.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-17 02:16:34 +02:00
glenn schrooyenandClaude 4584502adb DOC-8: HA manufacturer says EMS port; rebuild field guide PDF
checks / unit (pull_request) Failing after 41m1s
infra-pin / fresh (pull_request) Successful in 1s
Device id (identifiers) is unchanged; only the display text moves.
test_mqtt baseline updated for that one string.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-17 01:53:33 +02:00
glenn schrooyenandClaude fd08090360 DOC-8: say EMS port, not meter bus
checks / unit (pull_request) Successful in 40m22s
infra-pin / fresh (pull_request) Successful in 1s
The add-on is wired to the inverter's RS485 port labelled EMS. Reword
README, DOCS, config description, field guide source and HTML. The HA
manufacturer string is left unchanged: test_mqtt pins it byte for byte.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-17 01:09:42 +02:00
glenn schrooyenandClaude Opus 5.5 ea77c63552 CHANGELOG 0.18.2: say how a no-unit forecast shows; who needs a look
checks / unit (pull_request) Successful in 40m19s
infra-pin / fresh (pull_request) Successful in 1s
Review of PR #199. "Warns once" left out the Home row and the Settings
note, which stay while the fault lasts. "No option change" now points to
the one case that needs a look.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-16 21:48:05 +02:00
glenn schrooyenandClaude 75f4359aac Release 0.18.2
checks / unit (pull_request) Successful in 40m23s
infra-pin / fresh (pull_request) Successful in 2s
Version bump to 0.18.2 and a CHANGELOG section for SAFETY-118 (#198).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 20:54:29 +02:00
glenn schrooyenandClaude 7d52dc1c0f SAFETY-118: a missing peak forecast reading keeps the unit-fault state
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 40m19s
A missing reading (unavailable, unknown, failed read, non-numeric) no longer
clears the fault: no false 'used again' INFO, no repeated WARNING, the status
row stays. Adds pv.has_reading(). DECISIONS wording fixed; tests added.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 18:19:44 +02:00
glenn schrooyenandClaude f0b4e68e49 SAFETY-118: read the peak forecast in its own unit
checks / unit (pull_request) Successful in 40m20s
infra-pin / fresh (pull_request) Successful in 1s
peak_forecast_entity is read through pv.watts() by its unit_of_measurement;
the abs(raw) < 50 size rule is gone. No unit or a non-power unit means the
forecast is not used, with one warning per cause. The validator no longer
claims a kW sensor is taken as watts for this entity.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 16:00:34 +02:00
glenn schrooyenandClaude Opus 5.5 0ee3c3468b Release 0.18.1 review: CHANGELOG text fixes
checks / unit (pull_request) Successful in 40m18s
infra-pin / fresh (pull_request) Successful in 1s
SAFETY-118 line: the add-on already turns a kW forecast into W
(main.py read_inputs, abs(raw) < 50), so only the settings-page warning is
wrong. Rounding note and rows: the new settings page; UX-44 also changed
one DOCS line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-16 13:03:37 +02:00
glenn schrooyenandClaude dec8e7b69f Release 0.18.1
checks / unit (pull_request) Successful in 40m39s
infra-pin / fresh (pull_request) Successful in 2s
Version 0.18.0 -> 0.18.1 (patch, no option changes) and a closed 0.18.1 CHANGELOG section.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 12:08:58 +02:00
glenn schrooyenandClaude 1bd2ba1397 UX-44: contract label says every 15 minutes, not hourly
checks / unit (pull_request) Successful in 40m37s
infra-pin / fresh (pull_request) Successful in 2s
The settings page contract choice read "Dynamic, hourly" / "Dynamisch,
per uur". Belgian day-ahead prices are per 15 minutes since 2025-10-01.
Now "Dynamic, every 15 minutes" / "Dynamisch, per kwartier". One DOCS
line that called dynamic pricing "hourly pricing" now says dynamic.
test_ui_text.py part 7 fails if either label says hourly again.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 05:26:32 +02:00
glenn schrooyenandClaude 8c954acb36 UX-43: keep each field description to one sentence (STYLE)
checks / unit (pull_request) Successful in 40m31s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-16 02:29:31 +02:00
glenn schrooyenandClaude 8f72ab00d7 UX-43: tariff price fields take five decimals
ui.fixed_price, ui.day_price, ui.night_price and ui.periods step 0.00001
EUR/kWh (the period editor's price input took a hard-coded 0.01). A short
c-EUR/kWh hint is added to the four field descriptions, EN and NL.

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-16 01:40:40 +02:00
glenn schrooyenandClaude Opus 5.5 44cd1fde2a Release 0.18.0: review fixes to the CHANGELOG section
checks / unit (pull_request) Successful in 40m17s
infra-pin / fresh (pull_request) Successful in 2s
OPT-15 and OPT-20 rows: the retry is two inverters only, and OPT-20 no
longer claims no other battery moves. SAFETY-111 added to known issues.
MAINT-19 marked as from code reading. Wording fixes in the SAFETY-112 and
MAINT-11 rows, UX-38 and the price service note.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-15 22:35:47 +02:00
glenn schrooyenandClaude ccdb9dc17a OPT-20: test_opt20 points at MUTATION.md (test_bytecode part 5)
checks / unit (pull_request) Successful in 40m25s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-15 13:12:22 +02:00
glenn schrooyenandClaude 06339a2446 OPT-20: a refusal probe asks only PROBE_W, not the whole trade
checks / unit (pull_request) Failing after 40m47s
infra-pin / fresh (pull_request) Successful in 1s
The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.

modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-15 13:08:59 +02:00
glenn schrooyenandClaude c68fd275cc PRICE-01 round 3: replace the fixed-tariff notification with a log line and a settings note
checks / unit (pull_request) Successful in 39m6s
infra-pin / fresh (pull_request) Successful in 1s
G1: remove the false 'Fixed tariff not used' notification. One INFO line at
start and an info note beside the setting (EN/NL) when price_service has a
non-blank static_profile; the old notification id is dismissed at start.
DOCS, migration step 5 and DECISIONS rule 7 now say what the code does.
S05: whitespace-only static_profile counts as not set.
G2: maintenance_enabled read through MaintConfig.from_options().

Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 20:27:15 +02:00
glenn schrooyenandClaude Opus 5.5 2f261f8ba4 PRICE-01 review: spaced-token check passes the length rule; F3 default pinned
checks / unit (pull_request) Successful in 39m51s
infra-pin / fresh (pull_request) Successful in 1s
The spaced-token check used a 5-character token, which the new 16-character
rule refuses on its own, so a validator that stopped checking spaces passed
(reviewer mutation R06). It now uses a long token and checks the reason.

Also pin F3 with no maintenance_enabled key: the default (off) holds and no
no-price words show (reviewer mutation S04). Tests only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 19:58:50 +02:00
glenn schrooyenandClaude 0801776645 PRICE-01 round 2: the token on no page, fixed-tariff note, token length, F3 words, test gaps
checks / unit (pull_request) Successful in 39m0s
infra-pin / fresh (pull_request) Successful in 2s
F1: every password option is shown as ******** (set) or empty in /config/model
(options, running, ui) and in a stale refusal; the classic page draws it as a
password field; a save or validate that sends ******** or nothing keeps the
stored value. F2: a static_profile beside price_service is said once at start
(notification and log), not refused. F3 (owner, 2026-10-14): the no-price row,
Home line and notification only while maintenance_enabled is on. F4: tests for
the reviewer's R01 and R10. F5: price_service_token must be 16+ characters.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 18:56:51 +02:00
glenn schrooyenandClaude 4eb88f7fda PRICE-01: migration note, and the tests drive the real control cycle
checks / unit (pull_request) Successful in 39m36s
infra-pin / fresh (pull_request) Successful in 1s
- DOCS: the migration note said markup and taxes do not matter; with the
  provider they are added to the wholesale price. Step 4 and 5 now say what
  they set and what static_profile does while no source has a price.
- The gap tests run the notification through cycle(), where the check is
  called, so a check that is never called goes red.
- test header: the real-transport checks are section 11.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 17:03:05 +02:00
glenn schrooyenandClaude 87ad958842 PRICE-01: Dutch dates, no redirects with the token, more checks
checks / unit (pull_request) Successful in 39m2s
infra-pin / fresh (pull_request) Successful in 1s
- The notification, status row and Home line name an earlier day in the
  language of the text ("13 okt om 21:00"); the Dutch title is "Prijzen
  ontbreken", so the body no longer repeats it.
- The token request does not follow redirects: the host is fixed in code.
- A step back up to the saved prices is one INFO line.
- Tests: whole status payload free of the token, a redirect, the 5-decimal
  edge of the old average, modes plan equal to generic_dayahead's.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 16:54:11 +02:00
glenn schrooyenandClaude 9ac3a9d2bc PRICE-01: price_service provider, fallback chain, and the gate read from it
checks / unit (pull_request) Successful in 39m31s
infra-pin / fresh (pull_request) Successful in 1s
A new price source, `price_provider: price_service`: the owner's price server,
one fixed HTTPS host, a bearer token (new password option
`price_service_token`), wholesale energy only so markup and taxes are added as
for generic_dayahead.

The chain is server, then energy-charts, then the prices the history store
kept. A step counts only if it has a price for now. Each step down and back up
is one log line. With every source down a site plans from what it saved.

No price for now: one status row, one Home plan line and one notification, in
English and Dutch, cleared when a price returns. With this provider the
maintenance charge gate reads the provider's prices and keeps the Home
Assistant rule: the current 15-minute price is at or below today's average.

The token is hidden on the settings page, refused when missing, and taken out
of any error text. Other providers, `off` and the Home Assistant pair take the
road they always took (scripted-day probe against 0ce7d35: one line differs,
the refusal that lists the known providers). See
DECISIONS/PRICE-01-own-price-server.md.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 16:22:24 +02:00
glenn schrooyenandClaude 5ee1061398 MAINT-11 round 2: disable the cycle buttons that cannot work
checks / unit (pull_request) Successful in 38m43s
infra-pin / fresh (pull_request) Successful in 1s
Stop cycle is disabled on a battery that is not cycling. Start cycle is
disabled while any battery cycles and on a switched-off battery. Page only;
the add-on still refuses each of these. DECISIONS notes the one-battery case.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-13 23:18:21 +02:00
glenn schrooyenandClaude 21d8a944bc MAINT-11: start or stop the maintenance cycle per battery
checks / unit (pull_request) Successful in 38m46s
infra-pin / fresh (pull_request) Successful in 1s
maint_start and maint_abort take an optional unit. With two or more batteries
each Batteries card has Start cycle and Stop cycle buttons. One slot per site
stays: a start while a battery cycles is refused and names it (no queue). A
battery that is switched off, an unknown unit, and a stop on a battery that is
not cycling are refused with a plain message. A request with no unit is the
old call. The scheduler and the phase machine are unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-13 21:37:36 +02:00
glenn schrooyenandClaude Opus 5.5 7f0f00b01c OPT-15 review: pin the rolled export at 0 W and a battery past E; note the maintenance replay
checks / unit (pull_request) Successful in 38m30s
infra-pin / fresh (pull_request) Successful in 2s
Two survivors of the review's mutations get a check each in
test_price_run_fixes.py (X1: a held export credited negative in the rolled
quarter; X4: the hold extended by a reading already past E). DECISIONS: the
slow-battery quarter (3456 W, same on e3e4ba6) and the replay of a
maintenance phase starting during the hold.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-13 14:18:41 +02:00
glenn schrooyenandClaude 065792aad3 Merge release/1.0 (e3e4ba6) into opt15-price-run-fixes
infra-pin / fresh (pull_request) Successful in 3s
checks / unit (pull_request) Successful in 39m30s
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
  clears the chargers, a probing refuser included, while a battery drains
  (SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
  (`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
  its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.

Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
  until the quarter's first sample, as the old edge tick was not, so a
  standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
  off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
  F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
  drain and the day plan against the probe.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-13 12:15:44 +02:00
glenn schrooyenandClaude Opus 5.5 9b1fa758ad OPT-17: the solar forecast can come from several entities, summed
checks / unit (pull_request) Successful in 36m13s
infra-pin / fresh (pull_request) Successful in 1s
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.

- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
  day is summed. Hourly splits are merged when every member has one, else
  the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
  day's forecast unusable (no partial sum). A caution row names it by
  position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
  the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.

DECISIONS/OPT-17-several-forecast-entities.md has the rules.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-11 02:55:58 +02:00
glenn schrooyenandClaude Opus 5.5 35432ce065 Release 0.17.0
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 2s
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 23:29:13 +02:00
glenn schrooyenandClaude Opus 5.5 d12228d986 SAFETY-107: a refusal held under another writer is learned once
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 2s
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-09 03:03:06 +02:00
glenn schrooyenandClaude Opus 5.5 ef35f4b925 MAINT-14: accurate no-level wording per phase; name the limit that ended the charge
checks / unit (pull_request) Successful in 34m54s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 21:25:35 +02:00
glenn schrooyenandClaude Opus 5.5 f39e52efd3 MAINT-14: maintenance with no SoC reading: charge times out, drain holds at 0 W
checks / unit (pull_request) Successful in 35m13s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 20:37:01 +02:00
glenn schrooyenandClaude Opus 5.5 6836f61bd4 MAINT-13 round 3: provider site, hourly fixed-tariff check, faster tests
checks / unit (pull_request) Successful in 34m52s
infra-pin / fresh (pull_request) Successful in 1s
- A price-provider site with no fixed tariff is not a gate (its plan never
  sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
  5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 12:03:55 +02:00
glenn schrooyenandClaude Sonnet 5.5 f7b83cc75c MAINT-13 round 2: read the price gate without a new main.py option read
checks / unit (pull_request) Successful in 34m35s
infra-pin / fresh (pull_request) Successful in 1s
test_static_tariff forbids main.py reading `static_profile`; a small
static_gated() in static_tariff.py answers it, and the Controller keeps the
answer in `_price_gated` beside `cheap`.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-08 11:10:33 +02:00
glenn schrooyenandClaude Sonnet 5.5 6f05b2e4be MAINT-13 round 2: gate open when nothing holds the charge back; safety93 scenario restored
checks / unit (pull_request) Failing after 34m45s
infra-pin / fresh (pull_request) Successful in 2s
- gate_open is true with no price gate set up, in a cheap window, or while the
  pack is taking charge; the stall rule and timeout now work on a no-tariff site.
- reset the save timer on a phase change; exact 5 min gap-cap test.
- test_safety93: original timeout scenario kept (B finished) plus a case where a
  due B takes the slot after A's failure.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-08 10:29:46 +02:00
glenn schrooyenandClaude Opus 5.5 28eff568b5 MAINT-13: a full pack that stops at 98-99 % is not a failed charge
checks / unit (pull_request) Successful in 34m21s
infra-pin / fresh (pull_request) Successful in 1s
A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.

No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 09:36:06 +02:00
glenn schrooyenandClaude Opus 5.5 756b50ddbb Release 0.16.0
checks / unit (pull_request) Successful in 32m41s
infra-pin / fresh (pull_request) Successful in 1s
version 0.15.0 -> 0.16.0 and a closed ## 0.16.0 CHANGELOG section.
No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-07 23:25:14 +02:00
glenn schrooyenandClaude Opus 5.5 4707d37019 SAFETY-95 review: test the stale-link and contradiction legs; refusal +1 only
checks / unit (pull_request) Successful in 32m34s
infra-pin / fresh (pull_request) Successful in 1s
F1: test_safety95 checks that a dropped draining battery is this rule's
(stale link, N=3, 4000 W: grid import 676 W vs base 786 W); kills R2.
F2: _charge_track tested directly with a contradicting drain (SAFETY-91's
pin as a floor against a closed pack); kills R3. Today a drain contradicts
only through a refusal; the clause stays, as a contradiction sends 0 W.
F3: a drain ends on a refusal only when the battery will not give
(refused > 0, as _held_back()); one that will not take still drains.
Tested both signs; kills R8.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-07 16:41:16 +02:00
glenn schrooyenandClaude Opus 5.5 9c0314a826 SAFETY-95: N=1 identity for every drain end; plainer DOCS line
checks / unit (pull_request) Successful in 32m35s
infra-pin / fresh (pull_request) Successful in 2s
test_safety95.py: the N=1 byte-identity now covers all six drain ends
(Off and stale link were missing); end_at()/measure() read through a
default, so test_named_absence.py passes (it failed on bdec66e); a check
that a dropped battery's start is 0 W even under a pinned charge (it
kills a mutation that survived).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-07 14:36:36 +02:00
glenn schrooyenandClaude Opus 5.5 bdec66e97a SAFETY-95: a maintenance drain that ends hands back smoothly (N>=2)
When a battery's drain ended (done, Off, timeout, abort, stale link,
refusal), its drain floor stayed in the site target and landed on the
others: B 0 -> +1600 W in one cycle at a 1200 W house, exporting; under a
solar surplus B gave into the export.

Now, on that cycle, the loop starts from what the others stood at plus the
battery's new command, raised to the house's own point when the house needs
more (never above last cycle's start). While the battery settles, the loop
counts the batteries at its start instead of chasing the drain's tail on
the meter. Then one slew step a cycle. N=1 is unchanged.

test_safety95.py; DECISIONS/SAFETY-95-drain-end.md; one DOCS line.
test_modes.py: opt11 n2_maint re-pinned on purpose (its drain ends by a
refusal at 1655 s; B now stays at the house's 1420 W instead of 2500 W).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 12:44:25 +02:00
glenn schrooyenandClaude Opus 5.5 956711b801 SAFETY-96 review: keep the refusal count over a refused write; test a fast board
checks / unit (pull_request) Successful in 31m53s
infra-pin / fresh (pull_request) Successful in 2s
F1: resetting the count on each refused write hid a battery that really
refuses behind a link refusing 1 write in 3 (never learned; learned at
358 s with the count kept). F2: a board at 0 W before its link is stale
learned no refusal untested (mutation R7 survived); now a 1 s-lag case.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 05:46:32 +02:00
glenn schrooyenandClaude Opus 5.5 88b9cd470a SAFETY-96: a battery the loop cannot move does not freeze it
checks / unit (pull_request) Successful in 31m44s
infra-pin / fresh (pull_request) Successful in 2s
At N>=2 a battery out of the split (stale link), with refused writes, or
settling after a step the loop did not make (a charge end, a rejoin) now
counts in the freeze test at its command, not its reading. Its real power
still reaches the loop through the meter. At a drop its share leaves the
loop's start point (the others take over one slew step a cycle); at a
rejoin it enters at its reading. No refusal is learned while a battery's
writes are refused. N=1 and the 46 identity digests are byte-identical.

test_safety78 part 2: the dropped-drain case now rests at B 1510 W (grid at
its -10 W aim) instead of 1500 W; the drop no longer sends B to 2500 W.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-06 04:02:03 +02:00
glenn schrooyenandClaude Opus 5.5 1d28daf8a0 MAINT-10 review: warn when HA did not answer and TZ is UTC; test the 3 s budget
checks / unit (pull_request) Successful in 31m18s
infra-pin / fresh (pull_request) Successful in 1s
HA can take minutes to start (2026-10-05, 502 from the proxy). Then TZ holds,
which the Supervisor sets from HA's zone, so the hour stays right; only a TZ
of UTC there now logs a WARNING asking for a restart. A test pins the 3 s
budget on the zone request (a mutant without it survived).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 23:24:02 +02:00
glenn schrooyenandClaude Opus 5.5 0b6b34f563 MAINT-10: every pack at N=2, the next DST days, plainer upgrade note
checks / unit (pull_request) Successful in 31m20s
infra-pin / fresh (pull_request) Successful in 1s
test_maint10.py part 10: at two inverters both packs get the site zone, the
real Controller is identical for 11 UTC and 13 Brussels, and two due packs
across 24/25 Oct 2026 and 27/28 Mar 2027 start at the local hour on
successive days; a pack freed in the repeated hour does not start there.
Part 3 adds 28 Mar 2027. DOCS: an existing install keeps its saved hour, now
read as local time; an hour set to make up for UTC goes back to 19.
DECISIONS: the SAFETY-83 gate is met; section on two inverters.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 21:51:15 +02:00
glenn schrooyenandClaude Opus 5.5 08fb1235fc Merge release/1.0 (0.15.0 + SAFETY-90) into maint-10-local-start-hour
Conflicts: main.py's maintenance import (base added CHARGE, HOLD; branch added
site_zone) - both kept. DOCS maintenance table: base's longer drain-rate row
kept, start hour row at 19 / local.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 21:51:04 +02:00
glenn schrooyenandClaude Opus 5.5 8c6e5bca2e Release 0.15.0: correct the SAFETY-94/97 row, add the ±170 W known issue
checks / unit (pull_request) Successful in 29m6s
infra-pin / fresh (pull_request) Successful in 1s
Review round 1 (F1-F3) on PR #173.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 01:23:03 +02:00
glenn schrooyenandClaude Opus 5.5 64dddd64bf CI-14: infra-pin to admin/goodwe 3b4ff84 (WITNESS-09)
checks / unit (pull_request) Successful in 29m18s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 00:13:01 +02:00
glenn schrooyenandClaude Opus 5.5 dd5eb6fdc8 SAFETY-94 review: tests for three surviving mutants; record two gaps
checks / unit (pull_request) Successful in 28m7s
infra-pin / fresh (pull_request) Failing after 2s
- test_safety94 part 4: time under 250 W is not counted; a command that
  swaps direction every cycle is never refusal evidence; a reading moving
  away from the ask does not restart the evidence. These kill review
  mutants R1, R3 and R6, which survived the PR's tests.
- DECISIONS: at N=1 a battery with B's standby offset no longer latches
  a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after
  35/d s of wall time.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-04 01:17:52 +02:00
glenn schrooyenandClaude Opus 5.5 b307db1049 Release 0.14.0: version bump and changelog
checks / unit (pull_request) Successful in 27m2s
infra-pin / fresh (pull_request) Successful in 2s
Two inverters are now supported for maintenance and the peak guard
(SAFETY-91, SAFETY-93). No option changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 10:30:25 +02:00
glenn schrooyenandClaude Opus 5.5 69dc1f0e7b CI: bump infra pin to 0c04488 (admin/goodwe#62 FW-05, #63 WITNESS-08)
checks / unit (pull_request) Successful in 27m26s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 09:56:36 +02:00
glenn schrooyenandClaude Opus 5.5 4b81387908 SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery
checks / unit (pull_request) Successful in 25m35s
infra-pin / fresh (pull_request) Successful in 2s
The loop's integrator bound counts only on a cycle the loop decided. A battery
another owner set (maintenance, the peak guard, a safety limit) alarms only
when it gives more than saturation_w less than told for saturation_cycles
cycles. At N>=2 the loop is bounded while maintenance holds a battery, so it
does not wind and control comes back one slew step a cycle. The status row
counts episodes, not cycles. Digests re-pinned where behaviour changed on
purpose; DECISIONS/SAFETY-85-no-false-not-keeping-up.md has the list.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
2026-10-01 19:05:27 +02:00
glenn schrooyenandClaude Opus 5.5 1c41a1e412 SAFETY-86 review: hold the site at the peak floor while a HOLD gives
checks / unit (pull_request) Successful in 24m23s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 the holding pack's pin follows the guard's floor while the loop
still asks for +5000 W, so the ALLOCATOR "could not be placed" row was
re-logged on every 1 W change and filled the 40-row action log. While the
pin is raised, cycle() now files a site `hold` ceiling at the floor
(P_MAINTENANCE), as SAFETY-84 does for a charge. Filed only when the
holding pack gives; hi == the floor, so it never clashes with it.

Tests: a noisy N=2 house logs no ALLOCATOR row and at most one clamp
row (20 and 20 without the ceiling); the ceiling is the floor itself;
a CHARGE is not refiled at N=1. The DECISIONS entry records the owner's
2026-10-01 decision: the HOLD ends on its clock, no top-up.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 02:00:20 +02:00
glenn schrooyenandClaude Opus 5.5 ba31e7c8b1 SAFETY-86: peak guard outranks the maintenance hold
checks / unit (pull_request) Successful in 24m17s
infra-pin / fresh (pull_request) Successful in 1s
During a HOLD the holding battery gives what keeps the quarter at the peak
aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain
(SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the
other live batteries may place, so they give first. A site stop still
decides alone. The hold ends on its clock even if the level dipped.
Below the aim nothing changes (rows identical).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:56:34 +02:00
glenn schrooyenandClaude Opus 5.5 513183aba3 test_peak_margin: read the month peak on the runs' clock, not today's
Part 3 read the simulated September's peak with the wall clock, so from
2026-10-01 it read no peak and crashed on every tree (4ad8298 too).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 00:56:34 +02:00
glenn schrooyenandClaude Opus 5.5 43a52e7f60 SAFETY-84: maintenance charge at N=2 no longer stalls
checks / unit (pull_request) Successful in 23m57s
infra-pin / fresh (pull_request) Successful in 2s
At N>=2 a cheap-window maintenance charge files a site `hi` (`charge`,
P_MAINT_SHAPE) equal to what the charging pack's own `hi` places, so the
other pack never has to give against it. The charge is sized to the
quarter's headroom under the peak aim so it yields to the peak guard, and
to 0 W under a site safety stop. N=1 byte-identical (safety84_identity).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 19:47:15 +02:00
glenn schrooyenandClaude Opus 5.5 bc6d744c6c SAFETY-83 review: banked month peak and no false alarm during a drain
checks / unit (pull_request) Successful in 23m23s
infra-pin / fresh (pull_request) Successful in 1s
test_safety83 part 1: under a month peak banked above the limit the drain
is lifted to peak - margin, and a drain the guard raises (steady or with
5 s spikes that saturate it) gives no 'Load too high' alarm; the part 3
overload still does.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 13:41:47 +02:00
glenn schrooyenandClaude Opus 5.5 79b94024cb Merge release/1.0 (OPT-11 P4, #156) into safety-83-peak-over-drain
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 13:35:28 +02:00
glenn schrooyenandClaude Opus 5.5 b171ada894 Merge release/1.0 (SAFETY-78, #154) into opt11-p4-solar-forecast
checks / unit (pull_request) Successful in 23m54s
infra-pin / fresh (pull_request) Successful in 1s
Conflicts: modetrade.decide() takes both the day plan (targets) and
SAFETY-78's draining flag; the Why line keeps SAFETY-78's other_cycle
ahead of the plan's word (test added).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:37:09 +02:00
glenn schrooyenandClaude Opus 5.5 0b96e3191c OPT-11 P4 review: records and text
checks / unit (pull_request) Failing after 4s
infra-pin / fresh (pull_request) Successful in 1s
- DECISIONS: the Cheap hours change and why; the no-sun replay (the gain is
  Leftover solar buying the evening's shortfall; the forecast added 0.14
  EUR); the reconstruction bias stated plainly.
- DOCS: Cheap hours ignores the forecast; a reading from before midnight
  is stale.
- The forecast line: "Solar still to come today: ..." (it is what is
  left, and it stays within the 12-word limit).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:29:00 +02:00
glenn schrooyenandClaude Opus 5.5 a692560960 Merge release/1.0 (SAFETY-81, #155) into opt11-p4-solar-forecast
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:08:52 +02:00
glenn schrooyenandClaude Opus 5.5 fbd884797d OPT-11 P4 review: Cheap hours ignores the plan; midnight-stale forecast; stricter ids
- Cheap hours only fills to the ceiling with or without a forecast, as the
  design (section 1) says. Skipping the sun's share cost 0.31 EUR on real
  2026 prices (29.72 against P3's 29.41) and saved nothing on the P3 set.
- A forecast reading from before local midnight is stale: until the
  integration refreshes, "left today" is still yesterday's 0 and
  "tomorrow" is really today.
- Forecast entity ids must be sensor.[a-z0-9_]+ (they go into the
  /api/states/<id> path).
- House profile: a stored day that is not a date, or is after today, is
  dropped instead of kept forever.
- Text: the forecast line says "for the rest of today"; the learning line
  no longer promises "tomorrow" (a plan needs one full day).
- Tests for four surviving review mutants (hour sample floor, the dear run
  after the cheap run, share by room, daytime use) and the fixes above.
- Replay tool: `--fc zero` (a forecast of no sun).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:08:47 +02:00
glenn schrooyenandClaude Opus 5.5 7104515229 OPT-11 P3 option A review: wizard no longer says modes come later
checks / unit (pull_request) Successful in 15m14s
infra-pin / fresh (pull_request) Successful in 1s
Step 5 said "Choosing a mode for each battery comes in a later update",
stale since P1. It now points to battery modes on the Batteries screen
(EN/NL); test_setup checks the new line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 11:21:32 +02:00
glenn schrooyenandClaude Opus 5.5 b014fd2e16 OPT-11 P3 review: sale shows no money, honest sell text, tests for four surviving mutants
checks / unit (pull_request) Successful in 14m5s
infra-pin / fresh (pull_request) Successful in 1s
- A sale block on the plan no longer says "Worth up to" at the import
  price: a sale earns the lower injection price.
- The selling switch help (EN/NL) and DOCS say the grid pays less than
  power costs; DECISIONS records why P3 loses on the replay.
- test_modes_p3 part 11: modes on ignore the site trade switch (R13), a
  battery in maintenance takes no part (R10), a headroom stop latches for
  the period (R8). All three mutants survived before and are red now.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 03:51:15 +02:00
glenn schrooyenandClaude Opus 5.5 308adc9277 Merge release/1.0 (7995e4d, UX-13 P3) into opt11-p2-ha-entities
checks / unit (pull_request) Successful in 11m29s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 23:58:39 +02:00
glenn schrooyen 0951cb227f Merge release/1.0 into safety-79-peak-margin
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 11m36s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

# Conflicts:
#	goodwe_controller/app/uilayout.py
2026-09-28 23:56:33 +02:00
glenn schrooyenandClaude Opus 5.5 e5a0ba23d7 SAFETY-79: CI fixes - MUTATION.md pointer, no key-taking helper, fixture sized on the aim
checks / unit (pull_request) Successful in 11m36s
infra-pin / fresh (pull_request) Successful in 2s
test_peakguard's over-limit fixture now sizes its load against
cap - margin, so the floor it asks for is exact wherever in the quarter
the suite runs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 23:37:55 +02:00
glenn schrooyenandClaude Opus 5.5 7c4c8f5c66 SAFETY-79: peak guard keeps a margin below the limit
checks / unit (pull_request) Failing after 11m34s
infra-pin / fresh (pull_request) Successful in 1s
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.

peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 23:09:39 +02:00
glenn schrooyenandClaude Opus 5.5 ffc9a4d721 OPT-11 P1 review: a mode never beats the peak floor; SAFETY-03 kept at the rail
checks / unit (pull_request) Successful in 11m4s
infra-pin / fresh (pull_request) Successful in 2s
- arbiter: a mode now gives way only as far as a site limit above P_MODE
  needs (_unit_modes at N>1, _site_mode at N=1). Before, the modes were
  released only when the peak floor bound S, so a trade won above the floor
  kept them and placed less than the floor (an Off battery at N=1 went to 0 W
  under a 2000 W floor), and a capped grid charge released an Off battery.
  While released, held batteries weigh 0 and carry only the shortfall.
- control: a side of the loop bound that reaches the rail is left to the
  rail, so SAFETY-03's i_clamped still fires with every battery on.
- opt11_identity: add maintenance scenarios and a 6000-case arbiter digest
  (peak floor, trades, maintenance, refusals); a5dddad digests pinned.
- tests: test_arbiter part 11, test_control (g), test_modes (0/1 refused,
  loop bound counts live units only). DOCS and DECISIONS say the new rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 19:41:36 +02:00
glenn schrooyen 0a28f71872 Merge release/1.0 (28a49cc, SAFETY-73) into UX-13-p2-installer 2026-09-28 02:49:58 +02:00
glenn schrooyenandClaude Opus 5.5 06aa09e28c SAFETY-73 review: a refusal needs 22 s of evidence, and the cut-out warning is for giving only
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 10m11s
- REFUSED_SPAN_S: the 12 cycles of evidence must also span (SETTLE_CYCLES-1) *
  LOOP_TICK_S = 22 s. At a 1 s meter, lagged healthy readings refused both
  units 10-16 times an hour after load steps (site held 0 W). 2 s and slower
  ticks are unchanged.
- REFUSES_ABOVE_CUT_OUT only for a refusal to give power: a full battery that
  stops taking charge is always above its cut-out level.
- test_delivery: its wedged fixture (0.2 s cycles) no longer reaches a refusal;
  the release/1.0 checks are restored and a span check added.
- test_refusal_units: lagged-reading and full-battery plants, two new checks,
  U14/U15 in the mutation table. Stale "> 500 W" wording fixed. DOCS/DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 02:16:24 +02:00
glenn schrooyenandClaude Opus 5.5 1a9c7523c9 Merge release/1.0 (a36dca6) into SAFETY-73-per-unit-refusal
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 01:41:54 +02:00
glenn schrooyenandClaude Opus 5.5 5a8d832eba Merge release/1.0 (afd6af0) into SAFETY-73-per-unit-refusal
checks / unit (pull_request) Successful in 9m58s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 01:16:54 +02:00
glenn schrooyenandClaude Opus 5.5 016ed5a5a3 SAFETY-73: a battery that refuses, per inverter, with two or more
checks / unit (pull_request) Successful in 10m1s
infra-pin / fresh (pull_request) Successful in 1s
SAFETY-52's hold applied per unit at N>1 (owner, 2026-09-27, option R).
A unit that gives < 100 W for 12 cycles in one direction while asked
> 200 W, or trips its stale-reading gate on a ~0 W reading, gets a
P_SAFETY `refused` unit limit closing that direction, so the allocator
hands its share to the others within their own limits. Probe: a +-200 W
pin every 15 min, one unit at a time, only while the site asks 200 W that
way. All units refusing: the site law holds 0 W. Exits reseed the site
target from the wire. INFO plus one WARNING (REFUSES_ABOVE_CUT_OUT) above
the configured cut-out; SAFETY-42/43 no longer report a refusing unit.
N=1 unchanged.

test_refusal_units.py: cases a/b/c on flat and jitter registers against
the old behaviour, probes, recovery, exits; mutations U1-U13 all red.
TEST-19 no-fault campaign: 0 engagements in 5280 runs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 00:13:26 +02:00
glenn schrooyenandClaude Opus 5.5 15627c38a6 UX-13 P0: layout table, page<->options derivation, warning tier, entity list
checks / unit (pull_request) Successful in 9m32s
infra-pin / fresh (pull_request) Successful in 1s
The foundation for the new settings page. No visible UI change.

- app/uilayout.py: screen -> group -> part -> field for every option in
  config.yaml (67 fields, 11 derived, 0 hidden), with control, unit, display
  scale, step, entity kind, show conditions, Simple/wizard placement and
  "applies after a restart". Ranges stay in the schema, words in
  translations and the new app/ui_text/en.json.
- app/uimodel.py: options_to_ui()/ui_to_options() for the derived keys (one
  inverter vs the list, solar rows, static_profile from simple prices, a
  year-stamped region preset for the levies figure, and an OPT-11 hook for
  arbitrage_enabled that changes nothing yet). Unchanged derivations write
  the stored values back, so the round trip is exact.
- validate.py: validate.Note, a warn/info tier. Each logged warning is also
  a note when a list is passed; config_notes() adds checks that need live
  data (missing entity, a kW sensor read as W, a limit below this month's
  peak). /config/validate returns them as "notes". No refusal changed: 261
  recorded validator calls, 0 differ (tools/ux13_validator_calls.py).
- GET ha/entities: Home Assistant's entity list for the picker, read through
  hass.states(), cached 30 s, 10 s timeout. When HA is down it answers 200
  with the old list marked old, or an empty list that says why.
- DECISIONS/UX-13-one-layout-table.md amends UX-02's "no option key in UI
  code": keys may appear in uilayout.py and uimodel.py only, both tested.
- Tests: test_uilayout, test_uimodel (round trip over the recorded calls,
  the TEST-23 option files and config.yaml defaults), test_haentities, a
  warning-tier part in test_validate; test_messages scans notes and
  ui_text; test_pv and test_selfconfig part 7 widened on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 23:11:31 +02:00
glenn schrooyenandClaude Opus 5.5 1d33265aac test_price: grade the Why row of the same render, not a second read of why_words
checks / unit (pull_request) Successful in 9m20s
infra-pin / fresh (pull_request) Successful in 1s
Since UX-10 the waiting sentence counts its seconds when it is read, so the
second read could cross a second boundary on a loaded runner ("1 second" in
the row, "2 seconds" in the check). CI run 953 on this PR failed that way;
test_price.py passes locally on the same tree.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 17:04:55 +02:00
glenn schrooyenandClaude Opus 5.5 1f97c7652f SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Failing after 9m32s
At the BMS cut-out the saturation freeze held the last request for hours
(+5000 W for 11.87 h on 09-06, +1940 W for 3 h 55 m on 09-19) until the grid
error changed sign. compute() now carries a refused direction: after
SETTLE_CYCLES of a ~0 W reading against a larger ask it holds that direction
at 0 W, probes 200 W (below the gate's 250 W) every 15 minutes, and lets go
on charge, an answered probe, stop/start or another writer. A stale-reading
trip on a frozen ~0 W reading seeds the same hold, which ends SAFETY-59's
~70 s cycle. One inverter only; no SoC in the loop (SAFETY-25 Option A).

test_refusal.py drives the real Controller and gate; tools/replay_refusal.py
replays the 16-day capture. test_clamp.py and test_delivery.py re-baselined
where they asserted the old hold. DECISIONS/SAFETY-52 has the record and what
SAFETY-58/59 must take into account.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 16:43:27 +02:00
glenn schrooyenandClaude Opus 5.5 c628099e69 UX-11: the meter WARNING names the limit only, as 'over 30 seconds'
checks / unit (pull_request) Successful in 9m4s
infra-pin / fresh (pull_request) Successful in 2s
TEST-23 showed 'No meter reading for 30 seconds, over the limit of 30
seconds': the age is 30.4 s, which rounds to the limit. The limit alone is
always true at the moment the line is logged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:49:17 +02:00
glenn schrooyenandClaude Opus 5.5 29837dfaa7 UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- Every WARNING/ERROR line that reported a safety reason (direction, delivery,
  stuck meter, stale reading, peak guard, circulation, over-rating) now ends in
  the reason's code (messages.reason_code()). The reason itself, figures and
  limits included, is on a DEBUG line right after it and in the action log.
- The reasons and state.json are unchanged, so an old state file loads and
  shows the same way: every saved reason opens with its code.
- test_messages part 6 checks every WARNING+ line at 25 words as logged; nine
  non-safety families are listed with a reason and capped. The byte pin in
  test_watchdog now pins the meaning, in order.
- The meter logs one WARNING per quiet episode, and INFO when back, so the red
  row's "the add-on log shows why" holds. The Why line past the hold names
  the missing reading. Action log: "25 engagements", "Shadow mode off: ...".

No trigger, latch, threshold, log level, notification id, cadence, row colour
or banner order changed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 13:34:30 +02:00
glenn schrooyenandClaude Opus 5.5 2f1627e287 CI: bump infra pin to d637d0b (admin/goodwe#61, UX-10)
checks / unit (pull_request) Successful in 9m5s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 12:19:51 +02:00
glenn schrooyenandClaude Opus 5.5 f1a660881c UX-10: two INFO lines read better on TEST-23 (hours count, maintenance history)
checks / unit (pull_request) Successful in 9m2s
infra-pin / fresh (pull_request) Successful in 2s
"11 of 48 hours use yesterday's prices", and the maintenance-history line no
longer says "maintenance history" twice.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 11:03:30 +02:00
glenn schrooyenandClaude Opus 5.5 23a3a3f5b5 UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified
  as data or as a built text, and every built text is produced by the real
  code and checked. This is the gap the 2d scan had: it counted `%s` as one
  word, so reasons built by loop_clamp_note() and friends were never seen.
- Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept):
  OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak
  guard (codes now PEAK_GUARD*), the migration report, price feed, price
  history and gate reasons. Plurals via messages.times()/count().
- Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff
  "one every 15 minutes or every hour", "not final yet" dropped.
- Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO,
  aiohttp access log only at log level debug, settings warnings once per
  start, one plain line per Home Assistant outage (hass.Outage).
- INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE",
  "NOT_OBSERVED", "did NOT land", "AND".
- Display bugs: WHY_WINNER covers every winner and safety reason
  (main.why_key(), part 7 finds them in the code); the meter row is amber
  "waiting for the first reading" inside its limit after a start; the
  missing-reading age is counted when the page asks.
- STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section).

No change to safety behaviour, alarm levels, notification ids, triggers,
cadence or the banner cascade. One row colour changes (meter at start),
justified in DECISIONS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 10:58:43 +02:00
glenn schrooyenandClaude Opus 5.5 b878663b2d CI: bump infra pin to ecd3864 (admin/goodwe#60, UX-08)
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 8m55s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 08:42:01 +02:00
glenn schrooyenandClaude Opus 5.5 2c516a032c UX-08 2c: short refusals, error texts and option texts
checks / unit (pull_request) Successful in 8m50s
infra-pin / fresh (pull_request) Successful in 2s
Validator refusals name the setting by its label and key, say what is
wrong and what to change, and keep the rejected value and limit. Option
names and descriptions are short in en and nl; citations moved to DOCS
"For installers" and the test_translations citation check now pins the
instruction on the tab and the record in DOCS. No rule, key, schema,
default or exit code changed. Allowlist 167 -> 43 (log lines only).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 05:55:45 +02:00
glenn schrooyenandClaude Opus 5.5 571b884315 UX-08 phase 2b review: keep over-rating evidence, pin latch clearing, plainer rows
checks / unit (pull_request) Successful in 8m48s
infra-pin / fresh (pull_request) Successful in 1s
- During a bound episode an earlier over-rating count stays on the page (amber,
  under its own title); test_clamp pins it.
- test_messages pins that every latch row says how it clears.
- pv_entities description no longer claims the page names the entity (en, nl);
  allowlist hash updated for that option-desc line.
- Plainer texts: multi-inverter direction banner, "fine now" after an episode,
  and the e-stop, peak-forecast and peak-guard-waiting rows move to messages.py.
- TEL-12 DECISIONS points to UX-08 item 3 for the retired row rule.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 03:10:25 +02:00
glenn schrooyenandClaude Opus 5.5 696142bccc Merge branch 'release/1.0' into UX-08-status-rows
Brings in the infra pin bump (#132) so infra-pin / fresh runs against it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 02:41:05 +02:00