glenn schrooyenandClaude Opus 5 7cde5d862a Merge release/1.0 into SAFETY-18 - CHANGELOG only
MAINT-04 (#10) landed on release/1.0 mid-review, so both branches had
prepended a stanza. config.yaml and DOCS.md auto-merged clean; only the
CHANGELOG needed a hand. Both stanzas are kept verbatim, MAINT-04's
Unreleased above the new 0.5.2 - no text from either author edited.
MAINT-04 is unreleased and 0.5.2 is being cut here, so a release manager
may want to fold the two; that is an editorial call, not a reviewer's.

Full suite green on the merged tree: arbiter, control, loop, maintenance,
p1, validate, watchdog, freeze.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 03:20:26 +02:00
glenn schrooyenandClaude Opus 5 ffb8ec6373 MAINT-04 review: pin the default divergence with a check, not a comment
validate.py's comment said "if config.yaml's value moves, move this and
main.py's together" and nothing enforced it - a comment where a check
belonged, in a PR that elsewhere proves it knows the difference.

test_validate.py now reads main.py and maintenance.py directly and asserts
the divergence EXACTLY AS IT STANDS: config.yaml/validate.py at 2000,
main.py's two fallbacks and MaintConfig's dataclass default at 2500. It
records the mismatch rather than demanding it be closed, so it passes today
and goes red if either side moves - including when somebody closes it in
main.py, at which point the check and validate.py's block are deleted
together. Nothing in a file another ticket owns is touched.

The consequence is asserted through the real code as well as the literals:
with the key absent the validator accepts, MaintConfig builds 2500 W against
a 2000 W ceiling, and the arbiter resolves it to 0 W as a contradiction -
the bug rule 6 exists to catch, passing rule 6. Production-unreachable (the
Supervisor always supplies every key) but fully reachable from sim/inject.py
and the tests, which is where anyone debugging maintenance works.

Also: a CHANGELOG section for the upgrade path, covering both the case where
the Supervisor re-derives the default and the case where it persisted the
old one, since which applies was not verifiable without probing the live
install. And maintenance.py's timeout comment said 13.5 kWh where everything
else says 13.8 (300 Ah x 51.2 V, DoD 90); SAFETY-18 does not touch that file.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:51:40 +02:00
glenn schrooyenandClaude Opus 5 7aa1bd052e SAFETY-18: a meter frozen at a wrong-but-fresh value now raises an alarm
A meter that answers 200 OK with a stale document forever is ARRIVING on every
poll, so every freshness mechanism in the stack reads it as healthy while the
loop integrates a constant error and rails: 360/135/75 s at the live install's
max_w: 5000 for a meter frozen at 350/1000/>=3000 W. Fifteen minutes of a 5 kW
unattended import sets the month's billed capaciteitstarief peak.

The detector is a conjunction, not the bare unchanged_s threshold TEL-05
measured and rejected:

    unchanged_s >= meter_freeze_s   AND   |command| within 5 % of max_w

Both terms already existed and were already on the status page, and they fail
for independent reasons: at the converged point the command is nowhere near the
rail, and at the rail against a real load the kWh registers move in seconds. At
the shipped 300 s the relation is structural rather than a margin - the slowest
a healthy 1 Wh register can tick and still look unchanged is 12 W, which is
inside the 15 W deadband, so the command there is parked at 0 W.

Notification only, deliberately: an HA persistent notification with a fixed
notification_id, an ERROR log line, a UI event and a red status row. No claim,
no latch, no 0 W. A false trip parks the battery; a false notification costs an
alert. Only meter_source: homewizard_local is covered - the status page says
NOT COVERED elsewhere rather than pretending the guard is armed.

DOCS.md states the capacity-tariff exposure this does NOT close: peak_cap_w caps
maintenance charging and nothing caps the loop. That cap is SAFETY-07.

test_freeze.py grades both directions and was verified by breaking what it
watches (six mutations, all red): silent over the committed 40-minute converged
capture, silent over an hour of TEL-05's low-power case where the rejected bare
threshold is shown to fire, alarming on a genuinely frozen meter driven over
real HTTP through the real HomeWizardLocalSource (the rig's own hwsim freeze
fault when reachable), silent on the same railed command against a meter that is
still moving, and asserting on the service call that leaves Controller.cycle()
rather than on the watchdog's own flag.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:39:54 +02:00
glenn schrooyenandClaude Opus 5 878a6ce452 MAINT-04: refuse a maintenance charge the ceiling cannot deliver
config.yaml shipped max_w 2000 against maintenance_charge_w 2500. The
cheap-window shaping files Claim.limit(hi = -maintenance_charge_w) against
the supervised SAFETY limit's lo = -max_w, so lo > hi - the arbiter's
clause 3, correctly resolved to 0 W and logged as a CONTRADICTION.
Maintenance silently never charged in a cheap window on a default install,
and the only evidence read like a bug in the arbiter rather than like the
two numbers the operator set.

validate_startup_config() now refuses maintenance_charge_w > max_w, the
same shape as CFG-01's sign_disagree_w >= max_w. Equality is reachable
(-max_w is a single valid point) and is not refused. Demonstrated by
starting the add-on on the pre-fix pair: exit 78 and the refusal banner.

maintenance_discharge_w was checked rather than assumed and is NOT the same
case: the drain phase OWNS the actuator (Claim.set at P_MAINTENANCE), so
the ceiling clamps it to +2000 W and the arbiter's explain() names the
clamp every cycle. Loud, and it still moves energy - warned, not refused.

The shipped maintenance rates drop to 2000 so the defaults pass the rule;
max_w was deliberately not raised, because it is the supervised safety
ceiling. test_validate.py now reads config.yaml itself, so a default the
validator refuses cannot ship again.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
2026-08-30 02:28:09 +02:00
glenn schrooyenandClaude Opus 5 e40eb0768d SAFETY-02: the P_PEAK assertion was pinning the test's copy of the gate
Review finding 2, and it is the same duplication `disagrees()` just removed, so
it gets the same fix rather than a follow-up card.

`following_from()` in test_watchdog.py was a TRANSCRIPTION of the gate in
main.py, carrying "keep the two in step" as an instruction - which is exactly the
arrangement that does not keep two things in step. Measured: editing the shipped
gate alone to `winner in ("loop", "peak")` left every suite green while the
watchdog went blind for the duration of every peak event. The row whose whole job
is to force whoever lands peak shaving to come and change an expectation did not
do that.

The expression is now `watchdog.loop_is_following()`, called by main.py and by
the test. One definition, two callers, same reasoning as `disagrees()`: the copy
that drifts is always the one in the harness doing the grading.

⚠️ AND EXTRACTING IT WAS NOT SUFFICIENT - the drift proof still came out green
after the extraction, which is why it was worth running rather than assuming. The
realistic P_PEAK row has peak shaving asking for MORE than the loop, so the
magnitude term rejects it whatever `winner` says and masks the term under test. A
second row with peak asking for LESS makes `winner` the only deciding term. With
that row, widening the shipped gate fails two checks; without it, none.

Also enforcing the write ordering that was documented and not asserted: swapping
the two `store.set` calls passed everything. A store that fails the second write
now proves the property the ordering exists for - a crash mid-trip leaves a
reason with no latch, never a latch with no explanation. Swapping them now turns
that check red.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:59:46 +02:00
glenn schrooyenandClaude Opus 5 cc4e88490b SAFETY-02 review: a latch that a restart clears is not a latch
BLOCKER. `auto` was persisted and `sign_wd.tripped` was not, so reconstructing
the Controller against the same store - which is what a container restart does -
brought it back ARMED, into the same fault, unattended: tripped=False, banner
back to NOT READY, and it resumed commanding -1000 then -2000 W before
re-tripping 180 s later. "Restart the add-on" is the first thing an operator
looking at a FAILSAFE banner and a 0 W inverter will try, and under a supervisor
that restarts a crashed add-on it is a loop of three-minute wrong-direction
bursts. DOCS.md's "it does not clear itself" was false across a restart.

`sign_tripped` and `sign_reason` are Store keys now, beside the maintenance
state and for the reason store.py's own docstring gives. Written the moment the
trip happens - reason first, flag second, so a crash between the two can never
persist a latch with no explanation - restored in Controller.__init__, cleared
only by the operator's start. The regression is covered: reverting the restore
fails seven checks in test_watchdog.py.

Review follow-ups, no behaviour change:

- The arming gate is tested against the REAL arbiter. It is the decision the
  ticket turns on and it was asserted in three comment blocks and verified by
  nothing - every case passed `following` in as a literal. Twelve claim
  configurations now derive it from resolve(), including the redirect case
  `winner == "loop"` alone would have got wrong and the `lo` limit that raises
  magnitude without flipping sign.
- The MQTT `status: "failsafe"` value is tested. The check that claimed to cover
  it restated the line above it and never touched the payload.
- The worked example described a config that does not ship: at the defaults
  maintenance_charge_w 2500 against max_w 2000 is an arbiter contradiction and
  0 W, not a -2500 W charge. Rewritten at 1500 W. The contradiction is a real
  pre-existing bug - a default cheap-window maintenance charge silently never
  happens - filed separately and deliberately not fixed here.
- Forward hazard recorded at the gate: `winner == "loop"` disarms the watchdog
  under any higher-priority SET, and a peak-shaving strategy at P_PEAK IS
  grid-following in sign, so it would blind this for every peak event.
- disagrees() is public so the replay harness stops carrying its own copy of the
  predicate it grades.
- held_s takes the clock instead of reading one.
- The two limits are now each stated in both places rather than one each.
- The no-false-positive argument is tied to control.py's freeze permitting the
  command to cross zero; under the shrink-only encoding control.py records as
  rejected, this would false-trip on a load step.
- Measured figures corrected: 93.4 % / 4212 of 17280, per-cluster
  0.3/0.9/10.5/0.0, and the near-circularity of those figures is now stated
  rather than leaned on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 22:33:15 +02:00
glenn schrooyenandClaude Opus 5 9aed43990b SAFETY-02: a loop can be fresh, tracking and inside its rating and still push the wrong way
The stale-input watchdog asks whether the meter is still talking. The saturation
freeze asks whether the inverter can follow. The output clamp asks whether the
number is too big. A loop can pass all three while charging the battery out of
the grid, because the only thing wrong is the sign.

On 2026-08-20 a commercial controller did exactly that four times in one day,
for up to 77 minutes at a stretch, reaching a commanded -14 768 W against a
±5000 W inverter. app/watchdog.py compares the emitted setpoint against the
authoritative P1 figure and, when they oppose each other with both over 300 W
for 180 s continuously, files a failsafe SET claim at P_SAFETY, commands 0 W and
latches there until an operator starts control again.

Validated against that day rather than against an argument: sim/replay_sign.py
in the infra repo drives this module over the committed captures of both
2026-08-20 and the healthy 2026-08-23 and reaches 18 trips on the fault day -
every one inside a window NOTES.md §4.7 accounts for - and 0 on the healthy day.
The four episodes do share one signature: 0.3 / 0.9 / 10.5 / 0.0 % sign
agreement inside them against 92.9 % healthy.

Three decisions the ticket could not make:

- It is DISARMED whenever the grid-following loop is not what is driving. Sign
  agreement is a property of a loop that follows the meter, and a maintenance
  grid charge opposes the meter by design - 2500 W of charge into a house
  drawing 500 W is +3000 W on the meter against a -2500 W command, for hours.
  The gate tests the emitted number, not the winning claim's name, because a
  limit claim can let the loop "win" and still replace its value.
- The trip LATCHES. Commanding 0 W removes the command side of the comparison,
  so the disagreement always clears the moment the trip works.
- sign_disagree_w at or above max_w is refused at startup. The arbiter never
  lets a command exceed max_w, so such a threshold leaves the watchdog incapable
  of firing while the status page still reports it armed.

What it does not catch, said out loud: an inverter that ACTS opposite to its
command moves the meter further the same way, leaving command and meter in
agreement. That is the saturation freeze's job.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:51:35 +02:00
glenn schrooyenandClaude Opus 5 aae74d7571 SAFETY-12 review: name the safety claim that could not fire, and fix two figures
Review fixes.

A. test_loop.py takes 73 s, not the ~35 s claimed in three places. That number
is the whole defence against a future developer deleting a slow test, so it was
understated by 2x in exactly the place it matters. Corrected - and it is now
~95 s (measured 93 s), because this commit adds the scenario below rather than
trimming windows to make an inconvenient number smaller. Both call sites carry
an instruction to re-measure if the windows change.

B. "242 checks" was test_p1's own count quoted as the total for all five
suites. The real figure is 395 across the five, plus 14 here.

And the finding this PR should have led with. stale_input_s and the
`inputs missing -> 0 W` claim both live INSIDE cycle(), so pre-fix, on a meter
whose value happened to repeat, that claim could not fire at all. Constant
meter, SoC entity dying at t=4 s, one binary:

  pre-fix   final target 220.0 W, reason 'loop -> 220 W'
  post-fix  final target   0.0 W, reason 'safety -> 0 W'

The old controller held 220 W through the whole input outage with its status
line still reading loop -> 220 W, and layer 1 does not cover that on a
`meter_source: off` install - no P1 age sensor is published, so the firmware has
nothing to veto on, while the heartbeat keeps its watchdog fed. The pre-fix
behaviour was not "holds a stale command safely"; it was a failsafe a repeating
meter switched off. Asserted in test_loop.py, both halves.

Three points of reasoning tightened, none of them wrong before:

- the re-tune is unreachable by construction, not merely by the reset: the
  combined cycle rate is max(arrival rate, 1/floor), never the sum, and 1/15 s
  is strictly slower than the ~1/5 s arrival rate. That holds only while the
  floor exceeds the meter's update interval - and the schema minimum of 5 s is
  exactly the reference meter's interval. Flagged for validate.py, not fixed
  here.
- the ~11 s lower bracket is not only a dropped poll: a 5.0 s poller against a
  4.97 s meter beats, so about every 14 minutes the poller steps over an update
  entirely. Reaching 15 s takes a beat-skip AND a failed poll.
- the "freshness is decided upstream" guarantee is transport-conditional. On
  `meter_source: off` the grid figure comes straight from hass.number() with no
  age gate. Running the full law is still right; the claim is narrower than it
  was stated.

The 15 s default is not independently justified - it rests on the firmware's
30 s ingest veto and moves if that ever does. Said beside the constant.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:14:58 +02:00
glenn schrooyenandClaude Opus 5 8cc9438aec SAFETY-12: record the six-minute observation, not just the unit check
test_loop.py proves the property in 35 s. This is the same three scenarios run
for six and three real minutes each, on one binary, and it is what AC2 and AC3
were actually asked for: 1 cycle before vs 24 after on a constant meter with the
command stuck at 220 W against a 350 W import, and byte-identical write
sequences on both the converged and the normally-changing meter.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:48:49 +02:00
glenn schrooyenandClaude Opus 5 88cd97cc7a SAFETY-12: the loop thinks on a clock, not only when the number moves
run_control() ran cycle() only when the meter value differed from the previous
poll. A meter that repeats a value therefore ran no control cycles at all -
while the heartbeat kept re-emitting the last command and the firmware kept
putting it on the wire every 2 s. Layer 1 stayed fed and every indicator read
healthy, so a command computed from an old reading went on being executed
through whatever the load did next. TEL-05 measured it: 70 s at a literally
constant 350.0 W, 14 arrivals, zero cycles.

cycle_floor_s (default 15 s) is a deadline on the GAP between cycles, reset by
every cycle whichever trigger fired - not a second scheduler. On a healthy meter
it never elapses, so the cycle rate and the commanded sequence are unchanged;
test_loop.py asserts that by driving the real loop twice on one binary (a huge
cycle_floor_s reproduces the old behaviour) and diffing the writes.

15 s is bracketed: above the ~11 s worst gap on a merely-unlucky healthy meter
(~5 s arrivals, 1 s detection, one dropped poll retried on the next tick), below
meter_max_age_s and the firmware's 30 s ingest veto, and equal to stale_input_s.

A floor cycle runs the full law. Freshness is already decided upstream - past
meter_max_age_s the reading is None, which is a P_SAFETY 0 W claim - and the
integrator advances per cycle, not per second, so bounding the gap bounds the
accumulation.

Not a freeze detector: nothing here decides whether a repeated reading is true.
DOCS.md's "accepted deviation" passage is qualified rather than deleted - the
window is now bounded at 3 x cycle_floor_s instead of open-ended, and its
"nothing accumulates while it is stalled" argument is called out as having
covered windup and not staleness. Same correction in control.py's comment.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:29:16 +02:00
glenn schrooyenandClaude Opus 5 547d796c5d CFG-01 review: widen the rule, refuse the firmware-veto case, fix the stop footgun
Review findings, all confirmed in code before changing anything.

THE RULE DID NOT AUTHORISE ITS OWN BEST REFUSAL. The stated test was
"makes a safety mechanism inoperative, or makes a stated limit untrue",
and a blank setpoint_entity does neither - layer 1 pinning the inverter
at 0 W is the failsafe WORKING, as validate.py's own text admitted. The
real justification is a second, separate category: the add-on is inert
and indistinguishable from healthy. Stated as (a) and (b), with each
refusal tagged, and with both halves explicitly bounded - (a) is not
"any two numbers that could disagree", (b) is not "anything degraded".
Left implicit, the gap is where trivia-creep comes back in.

meter_max_age_s ABOVE THE FIRMWARE'S VETO IS NOW REFUSED. The schema
allows int(5,300); the firmware's threshold is a compile-time
`max_age_s: "30"` and it trips layer 1 at `p1_age_s >= 30`. At 120 the
add-on believes a 119 s reading is fresh and keeps commanding while the
board has already vetoed and is holding at 0 W - healthy meter, running
controller, nothing moving. Structurally identical to the max_w case,
and unlike max_w it is settable on this install, so the headline
behaviour finally has a live demonstration. That firmware file's own
comment says a lower bound on this "belongs in CFG-01, not here".

Only ABOVE is refused: below the veto the add-on gives up first, which
is fail-safe and visible on its own status page. Scoped to P1 being
enabled, because meter_max_age_s governs nothing otherwise.
FIRMWARE_INGEST_VETO_S cannot be imported from a compile-time YAML
substitution, so it carries a note on the single direction in which it
can go stale - and a warning that TEL-06 is editing `ingest_stale`, so a
matching integer may stop meaning a matching rule.

stop= WAS A LIVE FOOTGUN. It defaulted to None, which made a Controller
that cannot stop itself the DEFAULT one. On the late-refusal path that
meant: log the banner, return, and leave the process alive forever with
no control loop and no exit - the exact "inert but looks healthy"
failure this module exists to refuse. Now required and keyword-only, so
the broken shape does not construct; test_p1.py's five call sites pass
an Event.

That whole path had no test and no live demo. It has one now: it drives
run_control() against a device that only reports a narrower range once
the loop starts, and asserts it refuses, signals, returns, and writes
NOTHING - plus the converse, that an agreeing device leads to real
writes. This also covers the max_w composition that cannot be reached
through the Supervisor on the live install.

max_w <= 0 is refused. Schema-blocked in production, but
validate_startup_config() is the simulation suite's entry point too, and
a non-positive max_w inverts the arbiter's supervised bounds into a
contradiction that reads as a safety trip rather than a typo.

Verified live 2026-08-28 (backup goodwe_controller-cfg01r2-1787940076):
meter_max_age_s 120 refused with a message naming 120, 30, and THE
FIRMWARE WINS; no traceback; add-on restored byte-exact and running.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:05:10 +02:00
glenn schrooyenandClaude Opus 5 fc9bd89dca CFG-01: refuse to start on a configuration that cannot be honoured
main.py used to read the setpoint device's own +-5000 W rating, notice a
configured max_w above it, log one WARNING, and run anyway with
write_setpoint() quietly clamping. The operator's stated ceiling was never
the real ceiling and the only evidence had scrolled off the log. specs
§1.5 is explicit that such a config is refused at startup, not survived at
runtime.

validate_startup_config() runs in amain() before the broker, the web
server or any task exists, so a refusal cannot leave half a controller
running behind a UI. It refuses exactly three things, all sharing one
property - continuing makes a safety mechanism inoperative or makes a
stated limit untrue:

  1. max_w outside the setpoint device's own rating.
  2. No setpoint_entity: every write is a no-op, the device rating is
     never read, and the ESP32 heartbeat that holds off the layer-1
     failsafe never happens. It ran, looked healthy, and moved nothing.
  3. A meter_source that can never produce a reading. These were already
     caught, but they only DISABLED ingestion, which leaves grid None
     forever: permanent inputs-missing, 0 W, and a status page
     indistinguishable from a healthy meter nobody has fed yet.

Those last predicates move into p1.validate_meter_options(), which
build_source() also calls - one definition, two callers, not two
competing validators. ha_dsmr with half its entities and mqtt_p1 with a
blank topic gained the check the other two transports already had.

Deliberately not refused, because untidy is not unsafe: integrator_max_w
above max_w (the arbiter still bounds the wire to +-max_w, so the cost is
unwind latency - warned), a missing soc/batt entity (fail-safe and
already a red NOT READY banner), a setpoint entity that has not appeared
on the Core API yet (ESPHome is routinely late; re-checked in
run_control() once the real rating arrives), and a thin meter_poll_s
margin.

A refusal is legible as one: a banner saying in words that this is
configuration and nothing is broken, numbered problems, no traceback, and
exit 78 (EX_CONFIG).

Verified on the live add-on 2026-08-28, not by reading the code: a blank
setpoint_entity and a meter_poll_s equal to meter_max_age_s each stopped
the add-on with the banner and no stack trace.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 19:29:35 +02:00
glenn schrooyenandClaude Opus 5 c70239cac2 0.4.0: the meter transports that fit this house
TEL-04 and TEL-05 merged without a version bump, so Home Assistant would not
have offered the update - the same trap DEPLOY-01 caught at 0.2.1, recurring
because merging a feature does not touch the version.

ha_signed reads one signed entity. homewizard_local polls the meter's own API,
where every HTTP response is a genuine arrival - the property the firmware
watchdog needs, and the one HA cannot provide for a repeated reading.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-26 01:31:54 +02:00
glenn schrooyenandClaude Opus 5 4d41b0a79e TEL-05 review follow-ups: show unchanged_s, name a timeout, keep the poll task alive
Four follow-ups on the reviewed and approved TEL-05 work. Additive; no shipped
behaviour changes except the two failure paths below.

1. unchanged_s had no operator surface. DOCS.md told a reader "the transport
   tracks it as unchanged_s" and there was nowhere to look: main.py built the
   transport, scheduled run(), and never read the object again. The status page
   now shows it on the healthy P1 line. Still NOT thresholded and NOT folded
   into the age - that refusal was reviewed and upheld, because at the converged
   -10 W this controller aims for a 1 Wh register needs ~6 minutes to move, so
   any limit false-trips at the target operating point. The whole argument for
   leaving it to a human requires the human being able to see it.

2. The "equivalent mutant" note on the content_type guard was wrong, and the
   comment is downgraded to say so. web.Response(text=...) defaults to
   text/plain, so the fake meter CAN serve valid JSON under the wrong mimetype.
   Test added; shipped behaviour was already correct.

3. A timed-out poll logged an empty reason: str(asyncio.TimeoutError()) is "",
   so the status page read "last error:" and then nothing, on a hung meter, at
   the moment the battery had just gone to 0 W. Falls back to the class name.
   Note str(err), not `err or ...` - an exception object is always truthy.

4. submit() sat outside the try in poll_once() and run() had no except, so a
   raise would kill the poll task permanently and SILENTLY - safe (the age
   climbs, the controller commands 0 W) but indistinguishable from a dead meter.
   Both wrapped; poll_s is already the retry cadence, so no backoff.

Also a comment at the parse_homewizard range(phases) slice: a 3-phase meter
configured as 1-phase understates the capacity-tariff figure. Filed separately,
not fixed here.

242 checks in test_p1.py (236 before, 6 new). test_control 55, test_arbiter 18,
test_maintenance 21, all untouched and green. Each new check proved non-vacuous:
six mutations, six named reds, no suite aborts, sources restored byte-identical.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 21:17:36 +02:00
glenn schrooyenandClaude Opus 5 98109a9b91 TEL-05: read the meter, not Home Assistant's opinion of the meter
A fourth meter_source, `homewizard_local`, polling a HomeWizard P1's own
local API (GET /api/v1/data) instead of watching an HA entity.

The point is the age sensor. sensor.p1_sample_age_s is FW-01's watchdog
input, and on every transport we had it measured "time since the value
CHANGED", not "time since the meter REPORTED". Home Assistant offers
nothing better: a repeated reading emits no state_changed, advances
last_reported on neither serialiser, and state_reported cannot be
subscribed to at all. Measured twice - 70 s of a frozen meter on the
ENV-01 rig, and ten repeated readings against the live house. Our own
capture of this house's meter goes 42.2 s and 97.0 s between changes,
both past the default meter_max_age_s of 30, so the age sensor would
have commanded 0 W on a perfectly healthy meter.

Here every HTTP response is an arrival. The meter answered, now, with
its current reading; whether the number moved is not consulted. Five
identical readings are five arrivals.

Reuses TEL-01's pipeline rather than restructuring it: same split_signed
sign convention as ha_signed, same make_sample, same ingest stamping,
meter_max_age_s, clock-recomputed age, plausibility bounds and the §20
unsigned-decode rejection. A failed or timed-out poll submits nothing,
so it is a missing reading - never 0 W - and does not reset the age.
meter_poll_s (default 5 s, the meter's own rate) is checked against
meter_max_age_s once at startup, like the ha_signed entity ids.

⚠️ An arrival stamp cannot see a FROZEN meter, and no arrival detector
can - one answering 200 OK with a stale number is arriving. The local
API does expose what HA never had (the total_power_*_kwh registers stop
advancing) and the transport tracks it as `unchanged_s`, but it is
deliberately not folded into the age and not thresholded: this
controller regulates grid toward ~0 W, and at a converged -10 W the
export register needs six minutes to move by its 1 Wh resolution while
the power figure legitimately repeats. Thresholding that would rebuild
the false-trip limit cycle at the exact operating point we aim for.

test_p1.py 179 -> 236 checks. Still defaults to off.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 20:51:23 +02:00
glenn schrooyenandClaude Opus 5 e663e10245 TEL-04 review: unshadow the helper, validate config at startup, and record
what the rig proved about the age sensor

Review findings 1, 3, 5 and 6. Finding 2 is deliberately untouched - it is
its own ticket.

3. `built` was rebound at test_p1.py:816 by `built = build_source(...)`,
   silently disarming the build() wrapper for anything appended below it.
   Renamed to `sel`. Reproduced the reviewer's failure before fixing:
   appending a check that calls built() after that line gives
   `TypeError: 'HaSignedSource' object is not callable` and aborts at 163 of
   180; with the rename the same probe reaches 180 and passes.

5. DOCS.md now states the "length must equal meter_phases" constraint that
   config.yaml already carried, plus what leaving the list empty actually
   costs: on the surveyed reading the phases carry 2769 W of import while the
   connection nets 187 W, so the tariff quantity is understated ~15x.

6. build_source now checks the ha_signed wiring once at startup instead of
   once per telegram: a blank p1_net_entity, or a phase list whose length
   disagrees with meter_phases, logs an error and disables ingestion. Both
   otherwise fail in the single way indistinguishable from a healthy source
   nobody has fed yet - no samples, a climbing age, the watchdog holding the
   battery at 0 W, and nothing in the log.

1. THE AGE SENSOR. Measured on the ENV-01 rig against the real HomeWizard
   integration, meter frozen via hwsim's `?fault=freeze` seam (cleared in a
   finally:, rig verified restored):

     - websocket state_changed for the meter over 70 s : 0
     - last_reported advanced (REST serialiser)        : no
     - last_reported advanced (websocket serialiser)   : no
     - subscribe_events(state_reported)                : rejected,
       "Event filter is required for event state_reported"

   So Home Assistant exposes NO arrival signal for a repeated reading, and
   the proposed fix - stamp from last_reported via subscribe_entities - is
   not available. subscribe_entities listens only to EVENT_STATE_CHANGED, and
   as_compressed_state carries no last_reported at all.

   The age is therefore "time since the value changed", which on ha_dsmr is
   mostly harmless (a telegram moves several entities) and on ha_signed is
   not: one entity means a healthy meter under a flat load is
   indistinguishable from a dead one. Recorded loudly in DOCS.md, in the
   HaSignedSource docstring and in the CHANGELOG, with the measured 42.2 s
   and 97.0 s gaps from our own capture.

   meter_max_age_s is deliberately NOT widened. The two conditions produce an
   identical signal, so a larger number does not separate them - it only
   chooses which of the two errors you get, and it would disarm the watchdog
   for a genuinely dead meter as well. The honest fix is an arrival stamp the
   meter itself provides.

test_p1.py: 174 -> 179 checks, all green. Other three suites unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 17:34:37 +02:00
glenn schrooyenandClaude Opus 5 8b51a51e20 TEL-04: a third meter_source for a single signed entity
TEL-01 shipped ha_dsmr and mqtt_p1, and neither can read the meter that is
actually fitted here. The house has a HomeWizard P1 exposing ONE signed
entity, sensor.p1_meter_active_power (+ import, - export); ha_dsmr wants two
unsigned registers and refuses a negative one outright, which is every
exporting telegram. So sensor.p1_sample_age_s could not be produced at this
site, and FW-01's watchdog needs it - measured, not theoretical: the house P1
went 51.1 s and 36.2 s without a state change overnight, both past
meter_max_age_s 30, so without the age sensor the watchdog would false-trip
the battery to 0 W.

Adds meter_source: ha_signed, reading p1_net_entity (and optionally
p1_phase_net_entities in L1..L3 order for the capacity-tariff peak). The
derivation is split_signed(), sitting next to make_sample's subtraction for
the same reason it does - the moment a user is asked to write two template
sensors that split a signed value, the sign convention is back in unreviewed
YAML underneath a safety input, which is exactly what TEL-01 removed.

The transport is a subclass of HaDsmrSource overriding only _wanted() and
build(), so every rule TEL-01 established is inherited rather than
re-implemented: ingest timestamping, meter_max_age_s, the clock-recomputed
sensor.p1_sample_age_s republished ~1 Hz, the plausibility ceiling, the
"prime the cache from get_states but never build a sample out of it" rule,
"a reconnect emits nothing", and unavailable/unknown treated as a MISSING
reading and never as 0 W.

Defaults to off. An existing install is unaffected until it opts in.

test_p1.py: 122 -> 174 checks. Includes an end-to-end run of the new
transport against a fake Home Assistant websocket, and the sign convention
asserted against real captured readings from
sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json (-5710 W at
13:46 local under full sun is export; +775 W at midnight is import).

Non-vacuity: ten mutations of the new rules, each applied alone and reverted
byte-identical. Nine turn the suite red. The tenth - splitting the per-phase
signed values rather than passing them through - is an equivalent mutant,
because make_sample subtracts the two lists again and does not sign-check
per-phase figures. That is recorded in a ponytail: comment at the site rather
than left for the next reviewer to rediscover.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 16:44:22 +02:00
glenn schrooyenandClaude Opus 5 6c980e87b0 DEPLOY-01: bump version to 0.3.0, changelog for SAFETY-04 and TEL-01
Fixes the version collision noticed while planning DEPLOY-01: release/1.0
still carried version 0.2.1, identical to what is already running on the
live system, so Home Assistant would not have offered the update at all.

- config.yaml: version 0.2.1 -> 0.3.0 (minor: TEL-01 adds a feature,
  SAFETY-04 changes the control law's internals)
- CHANGELOG.md: 0.3.0 entry for SAFETY-04 and TEL-01, in the existing voice

No code under app/ touched, no option defaults changed. Verified:
meter_source: off, integrator_max_w: 0, target_grid_w: -10 all unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-25 10:33:17 +02:00
glenn schrooyenandClaude Opus 5 5184a2cfc2 Rest the meter just below zero, not at zero
The deadband is a one-way ratchet: any resting point inside it holds
indefinitely. Import and export are separate registers on the meter, so a
loop resting at +14 W bills 0.34 kWh/day while behaving perfectly.

target_grid_w (default -10 W) moves that residue onto the export register.
Worst billed rest point drops from 15 W to under 5 W. Behaviour is unchanged
at target_grid_w: 0.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-24 04:20:07 +02:00
adminandClaude Opus 5 017b798fe6 Precedence arbiter: one rule instead of an if/else ladder
Two controllers writing one actuator is the failure this system exists to
avoid. "Exactly one writer" was true, but only as a convention held up by
careful reading - which does not survive an EV charger and a heat pump wanting
the same battery.

Strategies now return claims and arbiter.py resolves them:

  highest-priority `set` wins (none at all means 0 W), then every `limit` whose
  priority is >= that set's applies, most restrictive first; contradictory
  limits command 0 W and are flagged as the bug they are.

The second clause is the whole point. "Money outranks maintenance" used to be a
hand-written exception inside a Jinja template; it is now a consequence of the
priorities - the charge-only limit binds the loop but cannot bind a
higher-priority peak claim.

Also: maintenance shaping moved out of control.py, which is a controller again
and not a policy engine; the loop now tracks the arbiter's actual output rather
than its own last wish, so it does not jump when it regains control; and every
decision explains itself ("loop -> 0 W, limited by maintenance(charge-only)")
in the UI and the log.

19 new assertions in test_arbiter.py, each one a precedence question someone
will eventually ask in the field. Deployed to the reference site as 0.2.0 and
holding grid within a few watts of zero.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 02:45:32 +02:00
adminandClaude Opus 5 594f8f9fc9 Six silent failures found by installing this on a live system
Migrated the reference site off the YAML packages and onto the add-on. Every
bug below presented identically: the add-on starts, logs "started", serves its
UI, and cannot do its job.

- run.sh needs #!/usr/bin/with-contenv sh. s6-overlay sanitises the environment
  for services, so a plain shebang means SUPERVISOR_TOKEN is absent and every
  Core API call is 401 - while homeassistant_api: true makes permissions look
  granted. Startup now prints the token length and probes the API.
- Supervisor keys the image by config.yaml `version`, so rebuilding without a
  bump reuses the old image. Two fixes appeared not to work because of it.
- Alpine is musl and has no aiohttp wheel on PyPI; deps now come from apk so
  nothing compiles on a client's Pi.
- Alpine ships paho-mqtt 1.x, which has no CallbackAPIVersion. That raised at
  construction and took the control loop down with it - so MQTT setup is now
  wrapped too. Observability must never be able to stop the controller.
- MQTT discovery is published from on_connect: paho silently drops QoS-0
  publishes issued before the CONNACK, so the previous code announced nothing
  while logging "MQTT connected".
- Repeated failures now log once a minute. Six warnings a second rolled the log
  buffer and destroyed the startup diagnostics needed to find the 401.
- auto_start could never fire, because the store's defaults always supplied
  auto: False for the fallback to find.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 02:25:58 +02:00
adminandClaude Opus 5 0a1e61dbc9 Packaged as a Home Assistant add-on, with a field guide
Turns the reference RS485 controller into something a technician can install
at a client site: a typed config form instead of YAML, an ingress UI that
names misconfiguration in words, and persistent state that cannot be broken by
a timezone.

Why an add-on rather than YAML packages or blueprints:

- Blueprints cannot create helpers, and the maintenance cycle is a state
  machine whose phase and completion date must survive restarts.
- YAML packages need filesystem access, a configuration.yaml edit and a
  restart - none of which belong in a client install.
- Add-ons authenticate with SUPERVISOR_TOKEN, so there is no long-lived token
  to generate, store or leak on someone else's machine.
- Requires HA OS/Supervised. Container and Core installs cannot run add-ons at
  all, which is a market decision, not an oversight.

The control law and the maintenance machine are pure functions with no Home
Assistant imports, and both ship with runnable checks (22 and 22 assertions).
Every assertion corresponds to a rule whose absence caused an observed failure
on hardware - the saturation duration term, the clamp-before-slew ordering, the
deadband, the sign convention.

One behaviour deliberately differs from the implementation it replaces: when
its inputs go missing this commands 0 W rather than replaying the last
setpoint. The reference version kept replaying, which the hardware watchdog
cannot catch - from the ESP32's side, Home Assistant is still talking to it.

Includes the ESPHome firmware (now parameterised: node name, inverter rating,
watchdog timeout) and the optional RS485 e-stop. FIELD-GUIDE.md carries the
commissioning gates, all judged on the wire rather than on how Home Assistant
looks, plus the written statement a site without an e-stop needs signed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016NckgXecasQb2eSsPYNSW6
2026-08-23 01:15:25 +02:00