Commit Graph
100 Commits
Author SHA1 Message Date
adminandClaude Opus 5.5 4cd604afcb SAFETY-91 review: a held-back battery is released 1 point above its reserve
checks / unit (pull_request) Successful in 26m26s
infra-pin / fresh (pull_request) Successful in 1s
A SoC reading flipping across the reserve swapped ~1000 W between the
batteries on each flip (grid +-500 W with unequal lags). Also grades
next_quarter()'s staleness boundary (29.5 / 30.5 s).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 14:54:20 +02:00
adminandClaude Opus 5.5 6872353e2e SAFETY-91: a held battery is drawn only after the others are full
checks / unit (pull_request) Successful in 26m19s
infra-pin / fresh (pull_request) Successful in 1s
At N>=2 a battery at or under its own peak reserve now weighs 0 whenever
the site gives (not only for the peak), a draining battery's pin becomes
a floor at its drain rate so it rises before the held one gives, and a
quarter's edge is graded on the next quarter when its first telegram is
late. SAFETY-25 option A stays: the held battery is still drawn once the
others are full. N=1 unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 14:03:54 +02:00
admin 8c438ab2e6 Release 0.13.0 (#164)
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 25m53s
infra-pin / fresh (pull_request) Successful in 1s
2026-10-02 10:04:13 +02:00
adminandClaude Opus 5.5 b37b7f95dc REL-0.13.0 review: plainer, truer 0.13.0 changelog
checks / unit (pull_request) Successful in 25m52s
infra-pin / fresh (pull_request) Successful in 1s
Crash, not stop, for SAFETY-61; Watchdog off by default; its own
warning for the 50 W peak margin (also under a higher month peak);
"refuses power" for SAFETY-52/73; no one-house options claim.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 09:37:34 +02:00
adminandClaude Opus 5.5 28cab03947 REL-0.13.0: cut 0.13.0
checks / unit (pull_request) Successful in 25m55s
infra-pin / fresh (pull_request) Successful in 2s
Bump config.yaml version 0.12.0 -> 0.13.0 and close a ## 0.13.0
CHANGELOG section covering every merge since 0.12.0 (a45ed06), with the
known issues SAFETY-90/91/92/93/94. Option surface 77 -> 83, none removed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 09:04:47 +02:00
admin 61072ca460 Merge pull request 'SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery' (#163) from safety-85-no-false-not-keeping-up into release/1.0
infra-pin / fresh (push) Successful in 1s
SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery (#163)
2026-10-01 20:52:17 +02:00
adminandClaude Opus 5.5 7b723a6cd5 SAFETY-85 review: grade discharge only, over the plant's settle time
checks / unit (pull_request) Successful in 25m47s
infra-pin / fresh (pull_request) Successful in 2s
Rule 2 graded each battery against last cycle's command and graded charges
too. On plantsim's battery (10 s lag) at the 2 s meter it warned at every
drain or charge start and 15 times an hour under the peak guard at N=2; a
charge tapering near full warned 11 times in 50 min (SAFETY-42 section 7).
Now a discharge is graded against the least it stood at over SHORT_CYCLES /
SHORT_SPAN_S. DOCS lists `mode-bound` under Loop reason. test_safety85 part 7:
peak guard with a dead battery, lagging plant, taper; part 3: the bound ends
with maintenance.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-01 20:25:41 +02:00
admin 935878193b Merge pull request 'SAFETY-87: peak guard uses every battery that can still give' (#162) from safety-87-guard-uses-able-batteries into release/1.0
infra-pin / fresh (push) Successful in 2s
SAFETY-87: peak guard uses every battery that can still give (#162)
2026-10-01 12:06:41 +02:00
admin b8ddfd787f Merge pull request 'SAFETY-86: peak guard outranks the maintenance hold' (#161) from safety-86-peak-over-hold into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-10-01 02:27:36 +02:00
admin 4ad8298ead Merge pull request 'SAFETY-84: maintenance charge at N=2 no longer stalls' (#160) from safety-84-n2-maint-charge into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-30 21:00:56 +02:00
adminandClaude Opus 5.5 5c9f64d87a SAFETY-84 review: check the charging pack gives under the guard, and no-P1 at N=2
checks / unit (pull_request) Successful in 23m51s
infra-pin / fresh (pull_request) Successful in 1s
A 6500 W house needs more than B alone: A must give (the N>=2 suspension),
with a non-vacuous run without it (banks over the cap, 'Load too high').
Without P1 the charge is not sized, as at N=1: A charges at 2000 W.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-30 20:36:46 +02:00
admin 9d5b7d129a Merge pull request 'SAFETY-83: peak guard outranks the maintenance drain at N=1' (#158) from safety-83-peak-over-drain into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-30 14:58:41 +02:00
admin 1145a931ac Merge pull request 'OPT-11 P4: solar forecast and day plan' (#156) from opt11-p4-solar-forecast into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-29 23:01:48 +02:00
adminandClaude Opus 5.5 56cafefa79 SAFETY-83: a refiled peak floor stays under a safety SET, graded directly
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s
Kills M5 (refiled at P_SAFETY) on its own sentence, not only through the
per-cycle claim check.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:52:52 +02:00
adminandClaude Opus 5.5 3f69c174af SAFETY-83: grade the refile at its boundary, and N=2 on its own
checks / unit (pull_request) Successful in 23m37s
infra-pin / fresh (pull_request) Successful in 1s
A floor exactly at the drain rate stays at P_PEAK (kills `lo >= rate`), and
part 4's N=2 check no longer shares its failure list with N=1.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:50:46 +02:00
adminandClaude Opus 5.5 d77f1b1fdf SAFETY-83: peak guard outranks the maintenance drain at N=1
checks / unit (pull_request) Successful in 16m54s
infra-pin / fresh (pull_request) Successful in 1s
At N=1 the drain is the site SET at P_MAINTENANCE (60), so the peak floor
(P_PEAK, 50) was not applied and the house imported what the drain left.
Where the floor asks for more than the drain rate, main.py now refiles the
peak claim at P_MAINTENANCE, so it wins; safety SETs still park everything.
Nothing else changes: safety78_identity --diff against 35cdffe changes only
cycles where the guard wanted more than the drain; N=2 is byte-identical.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:40:14 +02:00
admin 35cdffe766 Merge pull request 'SAFETY-78: maintenance drain at N=2 no longer stalls' (#154) from safety-78-drain-at-two into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-29 22:20:29 +02:00
admin 4f25b24aa6 Merge pull request 'SAFETY-81: no false Load too high alarms' (#155) from safety-81-load-too-high into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-29 21:45:19 +02:00
adminandClaude Opus 5.5 f967073cfe SAFETY-81 review: 10 s hold, ERROR line per episode, more scenarios
checks / unit (pull_request) Successful in 20m31s
infra-pin / fresh (pull_request) Successful in 2s
- The alarm must hold for peakguard.ALARM_HOLD_S (10 s) on the projection's
  clock. A load that tops cap + battery for ~5 s every 30 s alarmed at every
  quarter start while the quarter landed under the aim (sine4500_fast).
- A cycle with no battery reading leaves the hold alone.
- Notified once per quarter, but the ERROR line is written per episode.
- New sim scenarios (sine4500_fast, twice7000, step6500_gap) with 5a4cdc2
  digests; control still byte-identical. Unit checks for export and the
  hold across a missing reading. test_peakguard's saturated fixture moves
  the hold start back instead of waiting it out.
- DECISIONS and DOCS updated: costs of the hold, tolerance reasoning, the
  double count in control left to a follow-up.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 20:58:37 +02:00
admin 5a4cdc273e Merge pull request 'OPT-11 P3: price runs per battery' (#153) from opt11-p3-price-runs into release/1.0
infra-pin / fresh (push) Successful in 2s
OPT-11 P3: price runs per battery (owner option A: selling off, Leftover solar solar-only until P4) (#153)
2026-09-29 11:37:46 +02:00
adminandClaude Opus 5.5 7a00f12c76 SAFETY-79: peak guard keeps a margin below the limit (#151)
infra-pin / fresh (push) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 01:01:35 +02:00
admin 7337b791e5 OPT-11 P2: HA entities for battery modes (#152)
infra-pin / fresh (push) Successful in 2s
2026-09-29 00:13:49 +02:00
adminandClaude Opus 5.5 c664e38ef4 OPT-11 P2 review: refusals stay counted, removals survive a start with no broker
- A refusal past the log-once set or the 32 cap is counted in the log at
  1, 10, 100 and so on, so a repeated attack stays visible.
- The logged topic is printable only (no forged log lines).
- mode_announcement(): the start-up store logic, now tested with a real
  Store. A removed config topic stays stored, so a start with no broker
  cannot forget it (rename case tested).
- A test ties each HA mode option to the page's English name.
- packmode.enabled() is tested for "true", 1 and "false".
- Retained-command text, DOCS and DECISIONS updated to match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 23:58:34 +02:00
admin 7995e4df0f UX-13 P3: Simple view and Batteries screen (#150)
infra-pin / fresh (push) Successful in 2s
2026-09-28 23:44:26 +02:00
adminandClaude Opus 5.5 b310282729 OPT-11 P2: HA entities for battery modes
checks / unit (pull_request) Successful in 11m12s
infra-pin / fresh (pull_request) Successful in 2s
Each battery gets an MQTT-discovered Mode select and Use switch, only while
battery_modes_enabled is true. Commands go through handle_action(), the
/action path; refusals are logged once. Retained commands are never applied.
Turning modes off removes exactly the configs announced (kept in the store).
With modes off the announcement is byte-identical to ed739d4.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 23:12:04 +02:00
adminandClaude Opus 5.5 ed739d4cdb OPT-11 P1: per-battery mode limits, on/off, solar order (#149)
infra-pin / fresh (push) Successful in 2s
Reviewed: a mode gives way to the peak floor only as far as it needs; SAFETY-03 kept at the rail.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 19:53:22 +02:00
admin a5dddadf45 UX-13 P5: Dutch text, STYLE check, DOCS screenshots, period editor (#148)
infra-pin / fresh (push) Successful in 2s
2026-09-28 17:06:18 +02:00
adminandClaude Opus 5.5 8c34647d05 Merge pull request 'UX-15: setup-only mode, and wizard fixes F1, F2, meter entity, step 1' (#147) from UX-15-setup-only into release/1.0
infra-pin / fresh (push) Successful in 1s
Reviewed and live-tested on TEST-23: 0 service calls in setup-only mode; review comment 1896.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 15:27:27 +02:00
adminandClaude Opus 5.5 63e7e8a133 UX-15: mutations fail named checks, not crashes
checks / unit (pull_request) Successful in 10m38s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 08:54:26 +02:00
adminandClaude Opus 5.5 159d7461d8 UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.

Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
  its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
  changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 08:48:21 +02:00
admin 4de96752ff Merge pull request 'UX-13 P4: the setup wizard' (#146) from UX-13-p4-setup into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-28 06:23:16 +02:00
adminandClaude Opus 5.5 be57b87c34 UX-13 P4: the setup wizard for installers
checks / unit (pull_request) Successful in 10m22s
infra-pin / fresh (pull_request) Successful in 1s
The Setup tab draws the Installer view's page model one step at a time,
from each field's `wizard` step in app/uilayout.py: meter (with the kettle
test), inverters and batteries, solar (optional), prices, peak limit
(battery modes: "comes in a later update", OPT-11), check and start.
It reuses P2's controls and saves through /config/validate and
/config/save. No route was added.

- First run: /config/model says `setup_needed` when the stored options name
  no power request entity, or on a new install (no `setup_done` and no
  `auto` in the Store, control not started). The page opens #setup only
  when opened with no route. The wizard's save writes `setup_done`.
- Kettle test: GET ha/entities?entity= reads one entity now, in W. The
  change decides: up keeps meter_invert off, down turns it on; a net or
  import/export meter that goes down blocks the step with what to check.
- Last step: validate.setup_checks() beside the refusals: the meter reads,
  each power request entity exists in HA (bad if not, SAFETY-77), battery
  levels and power with direction, solar sign, prices. Saves with
  shadow_mode on by default, then a confirmed restart naming the 0 W.
- P2 test finding (a): a stale save lists only the keys the other surface
  moved (the blob handed out on open, by fingerprint, against stored now).
- test_setup.py; tools/ux13_wizard_blobs.py makes the 88 blobs the wizard
  can save; all accepted by Supervisor 2026.08.0 AppOptions (offline).
- DECISIONS/UX-13-setup-wizard.md; DOCS "Setup, for a new install".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-28 05:31:18 +02:00
admin 515c11b380 Merge pull request 'UX-13 P2: the Installer settings view' (#145) from UX-13-p2-installer into release/1.0
infra-pin / fresh (push) Successful in 1s
Merge UX-13 P2: the installer settings view (#145)
2026-09-28 03:54:23 +02:00
admin 28a49ccf75 Merge pull request 'SAFETY-73: a battery that refuses, per inverter, with two or more' (#143) from SAFETY-73-per-unit-refusal into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-28 02:27:15 +02:00
admin a36dca60dd Merge pull request 'UX-13 P1: page shell and Home screen on a structured /status' (#144) from UX-13-p1-home into release/1.0
infra-pin / fresh (push) Successful in 1s
UX-13 P1: page shell and Home screen on a structured /status (#144)
2026-09-28 01:29:30 +02:00
adminandClaude Opus 5.5 fad73d4012 UX-13 P1 review: Home draws only what the cycle would do
checks / unit (pull_request) Successful in 9m36s
infra-pin / fresh (pull_request) Successful in 1s
- Trade blocks: none on a battery with no room, no sale at a negative price
  or while the emptiest battery is at arbitrage's floor, nothing when a
  level is unknown. A give after a charge may use what the charge put in.
- The refusal line names the real reason: prices not published vs gap.
- The plan's peak line uses the guard's ceiling (this month's peak once
  above the cap), as the peak card does.
- House below zero: 0 W inside the idle band, no figure beyond it.
- Price bars are "Low price" / "High price": the add-on trades in one hour.
- Control toggle: one request in flight at a time.
- test_home: the new cases; the house-sign mutation now goes red.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 01:18:33 +02:00
admin afd6af068d UX-13 P0: layout table, page<->options derivation, warning tier, entity list (#142)
infra-pin / fresh (push) Successful in 2s
2026-09-27 23:49:32 +02:00
adminandClaude Opus 5.5 badea3cb2d UX-13 P0 review: keep unread keys, back off a failed entity read
checks / unit (pull_request) Successful in 9m30s
infra-pin / fresh (pull_request) Successful in 1s
- uimodel: editing a listed inverter keeps the stored flat keys, and a
  region of "own" keeps a stored price_taxes_profile (both were dropped).
- haentities: a failed read also waits CACHE_S, so polls while Home
  Assistant is down do not queue one 10 s read each.
- ui_text: the Flanders preset names its DSO, and the help says
  Wallonia and Brussels have no figures yet. REGION_PRESETS cites the card.
- tests: decode of a reversed solar row, both kept keys, the backoff.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 23:39:43 +02:00
admin 652097abde Merge pull request 'SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min' (#141) from SAFETY-52-refused-hold into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 18:21:21 +02:00
adminandClaude Opus 5.5 3c0f2b9669 SAFETY-52 review: a refusal is under 100 W, and any delivery ends it
checks / unit (pull_request) Successful in 9m22s
infra-pin / fresh (pull_request) Successful in 1s
- Engage (and seed from a stale stop) below REFUSED_BELOW_W, the probe's
  own 100 W answer, not below saturation_w: a battery derated to 100-499 W
  was held at 0 W ~93 % of the time.
- A reading of 100 W or more in the held direction ends the refusal, probe
  or not: at a 1 s meter SETTLE_CYCLES is 12 s, shorter than a healthy
  reading's lag, and that held a healthy step at 0 W until the next probe.
- test_refusal part 5b and a seed test; DOCS states the N>1 limit; the
  DECISIONS record carries the traced cause of the replay's extra trips.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 18:11:42 +02:00
admin d1f7e3336e Merge pull request 'UX-11: safety log lines give one plain sentence and the code, the figures go to DEBUG' (#140) from UX-11-short-safety-lines into release/1.0
infra-pin / fresh (push) Successful in 2s
Merge UX-11: short safety log lines, figures to DEBUG and events (#140)
2026-09-27 14:31:05 +02:00
adminandClaude Opus 5.5 3c298af3d8 UX-11 review: restored stops log their figures to events, the quiet-meter WARNING is rate-limited
checks / unit (pull_request) Successful in 9m7s
infra-pin / fresh (pull_request) Successful in 1s
- After a restart, each restored stop (direction per inverter and site,
  delivery, circulation) also writes its saved reason to the action log.
  log_level defaults to info and events starts empty, so the DEBUG
  evidence alone left the figures only in state.json.
- A flapping meter (ha_signed under a flat load, 42-97 s between changes)
  logs at most one WARNING/INFO pair per 10 minutes, with the episodes in
  between at DEBUG.
- LONG_LINE_OK refuses any key whose text is a safety reason.
- test_watchdog keeps the byte pin beside the meaning pin, since the text
  did not change.
- DOCS says the DEBUG line needs log_level debug.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 14:21:05 +02:00
admin c4032ebc21 Merge pull request 'CI: bump infra pin to d637d0b (admin/goodwe#61, UX-10)' (#139) from pin-bump-d637d0b into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 12:30:15 +02:00
admin 2b14b88cb4 Merge pull request 'UX-10: the last plain-language leftovers (log lines, two table rows, 'Why: Other', red at 0 s)' (#138) from UX-10-plain-leftovers into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 12:18:22 +02:00
adminandClaude Opus 5.5 e0b578756f UX-10 review: the line as logged gets the red-alarm shape, clamp lines at 30 words, plain HA 400
checks / unit (pull_request) Successful in 9m3s
infra-pin / fresh (pull_request) Successful in 2s
Part 6 checked the quoted reason alone, so title + reason + tails logged
as 4+ sentences. It now also checks the whole line (at most 3 sentences,
none over 30 words); 25 lines failed and are rewritten (one-sentence
wrappers, two-sentence circulation and peak reasons, STALE_READING's
fixed limits on a DEBUG line). The clamp lines for one inverter are
pinned at 30 words with OUTPUT_CLAMP and the numbers kept. Home
Assistant's bare '400: Bad Request' while it loads becomes one plain
line; still WARNING, throttled, a failed write.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 12:08:38 +02:00
admin 125b0702a2 Merge pull request 'CI: bump infra pin to ecd3864 (admin/goodwe#60, UX-08)' (#137) from pin-bump-ecd3864 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 08:52:21 +02:00
admin 32b9e56357 Merge pull request 'UX-08 2d: plain log lines, the rest of the status page, and DOCS' (#136) from UX-08-2d-logs-docs into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 08:40:33 +02:00
adminandClaude Opus 5.5 6a95447248 UX-08 2d: plain log lines, the rest of the status page, and DOCS
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m55s
Every WARNING and ERROR line is one plain line of at most 25 words, with
no card ids, capitals or semicolons; the reasoning of the ten longest is
on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0).

The status page: the month-peak and peak-guard rows, the stale-reading
row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the
Stopped banner and the line under the buttons, which now shows the plain
hint of each event instead of the raw action log. The Supervisor question
at start logs one line with a real reason.

Refusals are counted as shown (labels expanded, long cases driven), seven
were shortened, the card and parse errors lost their internals, a blank
value reads "empty", and the panel no longer files inverters.max_w under
the flat max_w. Option names lose "(JSON)", the NL texts are checked too.

DOCS gets a glossary (control board, isolator, Developer Tools) and card
ids move from headings to a "For installers" line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 08:01:16 +02:00
admin a02cd4b713 Merge pull request 'UX-08 2c: short refusals, error texts and option texts' (#135) from UX-08-2c-refusals into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 07:01:25 +02:00
admin e1d0970b23 Merge pull request 'UX-09: Details link for current HA, shadow wording, plain terms' (#134) from UX-09-2a-fixes into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 04:54:42 +02:00
adminandClaude Opus 5.5 63dee6db1e UX-09 review: short start-up timeout, latch rows pinned in shadow, plainer rows
checks / unit (pull_request) Successful in 8m50s
infra-pin / fresh (pull_request) Successful in 1s
The Supervisor questions for the Details link are asked together with a
3 s budget instead of one after the other at 10 s each, so a hung
Supervisor cannot hold control start for 20 s. In shadow mode the
circulating and site-direction latches are pinned to keep their own red
row that says how they clear. Plainer inverter and battery wording.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 04:45:06 +02:00
adminandClaude Opus 5.5 00e3ee9de8 UX-09: Details link for current HA, "would" in shadow mode, plain terms
infra-pin / fresh (pull_request) Successful in 2s
checks / unit (pull_request) Successful in 8m50s
- Details link: /config/app/<slug>/documentation on HA 2026.2+ (the old
  /hassio/addon path is a 404 from 2026.5), /hassio/addon on 2026.1 and
  older. Slug from GET /addons/self/info, version from GET /info, hostname
  as fallback.
- Shadow mode: the over-rating alarm and row say what would have been sent,
  the peak alarm no longer says the battery is giving all it can.
- "controller" -> "the add-on" / "control". Settings named by their labels;
  four labels changed to match (Peak reserve, Battery level entity, Solar
  production ..., Reversed-sign solar entities).
- Shadow banner and inverter link notes moved to messages.py and checked.
- DOCS Notifications and Status page rewritten for home owners, with a
  "For installers" part each. Allowlist 168 -> 167.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 04:10:39 +02:00
admin d57767fe38 Merge pull request 'UX-08 phase 2b: short, plain status rows and page banners' (#133) from UX-08-status-rows into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 03:19:54 +02:00
adminandClaude Opus 5.5 d017fc67bf UX-08 phase 2b: short, plain status rows and page banners
checks / unit (pull_request) Successful in 8m47s
infra-pin / fresh (pull_request) Failing after 1s
Every Commissioning row and every page banner is now worded in
app/messages.py (row_*, banner_*): one sentence of at most 15 words, a red
row up to three sentences so a latch still says how it clears, banners at
most 12 words. No row names a Home Assistant entity: sensors by their
setting, solar sources by their place in the list. Reason codes and limits
stay on the log line and event list; rows keep the numbers a reader acts on.

UX-07 item 1: ClampWatchdog counts over-rating and integrator-bound
engagements separately, and after an episode each count shows under its own
alarm's title instead of both under "output clamp".

No row colour, visibility or banner order changed. Rows carry an "id" so the
tests pin meaning rather than wording. The row and banner kinds leave the
allowlist (200 -> 168, cap equal). DOCS.md gains "Status page"; choices are in
DECISIONS/UX-08-short-notifications.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
2026-09-27 02:12:10 +02:00
admin 5c151a3458 Merge pull request 'CI: bump infra pin to 7081df4 (admin/goodwe#59, UX-08)' (#132) from pin-bump-7081df4 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 01:41:37 +02:00
admin 48ef06ac1f Merge pull request 'UX-08 phase 2a: short, plain notifications, and a ratchet for the rest' (#131) from UX-08-plain-notifications into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-27 01:29:46 +02:00
adminandClaude Opus 5.5 7b65a3e69a UX-08 review: tighter notification texts, and two meaning fixes
infra-pin / fresh (pull_request) Successful in 1s
checks / unit (pull_request) Successful in 8m48s
- not delivering: the body said control keeps running and then "start
  control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
  i.e. an inverter's cut-out level missing; it now names that. The title
  is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
  meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
  DECISIONS no longer states the HA anchor behaviour as fact.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-27 01:18:55 +02:00
admin 2503de124e Merge pull request 'SAFETY-40: the integrator bound is not a BUG SIGNAL; alarm numbers from the clamp tick' (#130) from SAFETY-40-clamp-alarm into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-26 23:19:11 +02:00
admin 59415ea83f Merge pull request 'CI: bump infra pin to 7689816 (admin/goodwe#58, SAFETY-34)' (#129) from pin-bump-7689816 into release/1.0
infra-pin / fresh (push) Successful in 2s
2026-09-26 16:15:23 +02:00
admin 397dd15dba SAFETY-34: re-assert latched alarms after a Core-only restart (#128)
infra-pin / fresh (push) Failing after 1s
2026-09-26 16:03:16 +02:00
admin fe132515fe Merge pull request 'CI: bump infra pin to a1d0618 (admin/goodwe#57, TOOL-9)' (#127) from pin-bump-a1d0618 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:52:59 +02:00
admin 82f032e8cf Merge pull request 'TOOL-9: pin checks print FAIL under pipefail; job tokens via header' (#126) from TOOL-9 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 20:39:47 +02:00
admin 6a8a5ffa27 Merge pull request 'CI-12: CI grades test_freeze.py against the real hwsim at a pinned admin/goodwe' (#125) from CI-12 into release/1.0
infra-pin / fresh (push) Successful in 1s
2026-09-25 18:19:43 +02:00
admin 16c796fa30 Merge pull request 'TEL-14: PV sign declared per entity (pv_invert_entities)' (#124) from TEL-14-pv-sign into release/1.0 2026-09-25 01:30:33 +02:00
admin 20260e86ec Merge pull request 'DOC-5: tell installers to turn on the Supervisor Watchdog' (#123) from DOC-5-watchdog into release/1.0 2026-09-25 01:17:35 +02:00
adminandClaude Opus 5.5 7fa045af85 TEL-14 N1: trim DECISIONS (drop probe transcript, §1 to the reason), move the mutation ledger there with M2/M5
checks / unit (pull_request) Successful in 8m44s
test_pv.py part 11 now prints a one-line pointer instead of the 12-row table.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 01:11:40 +02:00
adminandClaude Opus 5.5 93f349a6af TEL-14 B1: pin stray caution on the reported case and whitespace normalisation end to end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 01:10:13 +02:00
admin 43b274035f Merge pull request 'TEST-26: a missing value in a check is a named FAIL, not a traceback' (#122) from TEST-26 into release/1.0 2026-09-25 00:57:20 +02:00
admin 3e38bafcee Merge pull request 'SAFETY-62/SAFETY-60: operator tools refuse input they cannot read' (#120) from SAFETY-62-refuse-unread-input into release/1.0 2026-09-25 00:25:22 +02:00
admin 6e6527224a Merge pull request 'SAFETY-61: the control task's death ends the process, after the wind-down' (#121) from safety-61-control-task-death into release/1.0 2026-09-25 00:07:41 +02:00
admin fa3d237ce1 Merge pull request 'DOC-1: operator docs name the real P1 entity and a roster that starts' (#119) from doc-1-operator-docs into release/1.0 2026-09-24 23:42:13 +02:00
adminandClaude Opus 5.5 29ca9b5157 DOC-1: operator docs name the real P1 entity and a roster that starts
checks / unit (pull_request) Successful in 8m8s
- DOCS.md / config.yaml: the watchdog's P1 age entity is
  sensor.goodwe_p1_sample_age (device "GoodWe" + "P1 sample age", as
  app/mqtt.py announces and the live install recorded), not
  sensor.p1_sample_age_s.
- DOCS.md: the inverters: example and per-entry table carry the required
  bms_soc_floor (and capacity_kwh); config.yaml's schema comment says four
  required keys, not three.
- Field guide: marked v0.1.0/outdated; slew_w row no longer recommends the
  1000 W that SAFETY-39 now refuses. HTML regenerated; the PDF is NOT
  rebuilt (no Chrome here). README/DOCS pointers fixed.
- test_docs.py: the documented roster must pass app/validate.py and the
  schema's per-entry keys; the documented entity id must equal the id
  composed from app/mqtt.py; the wrong id may appear in no shipped doc.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:24:50 +02:00
adminandClaude Opus 5.5 a45ed06c05 PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0 (#117)
checks / unit (pull_request) Successful in 8m0s
Reviewed at head 1ad4d3a. CI run 830 (attempt 1, pull_request, PR 117 -> release/1.0), 31/31 PASS. Review: #issuecomment-1588, #issuecomment-1589.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:09:28 +02:00
admin f863ecaa8c TEL-12: several PV inverters, and one absent member is an absent TOTAL (#116)
pv_entity becomes a roster: pv_entities beside it, replacing it, with the SITE total over the roster. One absent member makes the TOTAL absent - never the partial sum of the ones that answered, because a smaller number indistinguishable from a real one reads a week later as 'there was less sun than there was', which is the conclusion OPT-10 exists to test rather than to manufacture. A member honestly reporting 0 W is still summed.

Reviewed on PR 116. Re-run independently: supervisor_shape_probe.py SSG (exit 0, transcript reproduces byte for byte), the owner's real 75-key options blob through Supervisor 2026.08.0's own AppOptions (ACCEPTED, zero drift on any stored value, pv_entities defaulted to []), tel11_pv_trace.py --compare across both trees (every hash reproduces, control 846a10a5b89e unmoved on unset and one), the rejected-design mutant (trace REFUSED 5/5 with the partial sums named), the planted leak N8 (52/26/10 red cells), and eight mutations on fresh purged copies including N5 sum->max at +0 bytes - no survivors. Habit 24's central claim measured: TEL-11's own --compare refuses on every honest run now that release/1.0 is 0.11.0.

Green traced to this PR's own run: 829/1954, attempt 1, event pull_request, path checks.yml@refs/pull/116/head, payload naming PR 116 with base release/1.0 @ cccb2fa, 31 suites PASS in 7m53s - a real execution, not a laundered skip.

Not deployable as merged: config.yaml stays 0.11.0 and the CHANGELOG entry is PKG's call.
2026-09-24 22:41:19 +02:00
adminandClaude Opus 5 0ef9565071 TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner
reported within minutes of it going live that they have several PV inverters
and could configure one - which is ordinary for a multi-string roof, not a
property of one house. `pv_entities` is the roster and the row carries the
SITE total.

⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`,
and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL
ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no
irradiance" conclusion the channel exists to TEST. So `pv.total()` answers
`None` the moment any configured entity is absent: the topic carries HA's own
`None`, the entity goes to `unknown`, the recorder records a GAP. The
alternative (the partial sum beside a contributor count) was implemented and
run as mutation N1b; it loses because the MQTT row is read COLD a week later by
an attribution that would believe it, while the qualifying count would live in a
second entity with its own history. The partial information is not thrown away -
the STATUS PAGE names every entity that reported, with its watts, and every one
that did not, with its reason, because that surface is read LIVE by a human who
wants the diagnostic.

⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is
`is None`, never falsiness - a roster that blanked the site on a zero would
report an absence on every clear evening.

THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list:
tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an
0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and
deepmerge's list strategy is `override` so a `[]` default does not rescue it -
the live add-on would not start. `match(.*)?` does accept both shapes and is
rejected for a different, measured reason: it validates nothing (a string, a
list and the integer 417 all pass) and renders as a plain text box. So
`pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for
`inverters:`, with a status caution saying which key won - a union would
double-count the inverter the old key still names.

STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than
replaced and now grades five claims over three document sets. The control hash
is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the
roster control document is byte-identical between the two trees. 2/5 is a claim
TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly
as 0.11.0 does" is a real cross-tree identity over control AND telemetry.

⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit
24: a discriminator defined as "the baseline lacks this feature" dies on the
release that ships the feature, and dies as a false refusal.

Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B
(`sum` -> `max`, the same three characters) and was run on a fresh copy with
`cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO
contributions in two units with absence driven at EVERY position - a member
contributing 0 W could go absent without moving the sum of the rest, which is
habit 23 with a coinciding value in the arithmetic rather than in the plant.

31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0,
so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG
entry is wanted and deliberately not written - 11b forbids `## Unreleased` and
the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the
material it needs.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:13:25 +02:00
adminandClaude Opus 5 cccb2fa07b PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1 (#114)
checks / unit (pull_request) Successful in 8m1s
Bumps config.yaml 0.10.1 -> 0.11.0 and adds the `## 0.11.0` section, so the Supervisor offers the update that carries SAFETY-56's wording fix and TEL-11's `pv_entity`.

Reviewed at head b11bea7. Green traced to this PR's own run (827, attempt 1, payload names PR 114 base release/1.0, 31/31 real). Version gate 11a-11d, SAFETY-56's behaviour hash and TEL-11's four trace rows all re-measured on this tree and matching. slug unchanged; option surface 75 -> 76 with no validator rule added.

Two non-blocking findings recorded on the PR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 19:20:06 +02:00
adminandClaude Opus 5 b11bea70d3 PKG-17: the SAFETY-57 correction pointed at the wrong paragraph
checks / unit (pull_request) Successful in 8m13s
Self-review. The note added to `### SAFETY-57` said the reading rule it is
qualifying is "two paragraphs up"; it is in the paragraph directly above - the
same one the note follows. A changelog that misdirects a reader to a paragraph
that is not there is the small end of exactly the defect this cut is fixing
three sentences of elsewhere, so it is corrected rather than left.

Text only, one line pair, still two files in the branch's diff.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 19:01:35 +02:00
adminandClaude Opus 5 cfafdffaed PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1
checks / unit (pull_request) Successful in 8m0s
Two files, and no third. config.yaml 0.10.1 -> 0.11.0; CHANGELOG.md gains
`## 0.11.0` and three corrections to sections below it.

A MINOR BUMP, NOT A PATCH. TEL-11 adds an option - `pv_entity`, 75 keys -> 76 in
`options:` and `schema:` together - which is the same test 0.8.0, 0.9.0 and
0.10.0 were cut on. Nothing here can refuse a stored blob: the key is `str?`
with an `options:` default of "", validate.py does not mention it, no default
moved and no enum widened, so a blob that starts the add-on on 0.10.1 starts it
on 0.11.0.

THE TABLE HAS TWO ROWS AND THE WINDOW HAD FOUR MERGES. CI-9's follow-up
(9f6b9f1, `.gitea/workflows/checks.yml` only) and SEC-2 (239e120,
`docs/RELEASE.md` + README.md) are excluded under PKG-15's rule - AUDIENCE, NOT
IMPORTANCE. Neither file is under `goodwe_controller/`, neither is in the built
image, neither is in predeploy_check.py's RUNTIME tuple, and there is no version
of this add-on on which an operator can observe either. SEC-2 is the closer call
and the section argues it in full rather than asserting it: it is the more
consequential ticket of the two - it is why this release is a pull request
rather than a push to master - and it is still a procedure for whoever cuts a
release, not something the person deciding whether to press Update can act on.
Both are named in the section with pointers to PR #102 / checks.yml and PR #108
/ docs/RELEASE.md.

WHAT THE ENTRIES LET AN OPERATOR DECIDE. SAFETY-56: behaviour byte-identical
(6030175ed2ab..., reproduced in the CI image over 2390 capture reads, a 66-cell
grid stepped 120 times and six driven worlds), three surfaces named with the old
and new wording side by side - the STALE_READING line quoted onto the action log
and status page, the SAFETY-37 ERROR log line, and the readiness row that
asserted a false fact about a named entity. TEL-11: unset is byte-identical in
BOTH the control and telemetry documents, set is byte-identical in the control
document only; the three TEL-11 rows of that table were re-measured in the CI
image on this tree (control 846a10a5... twice, telemetry a443a6ce... / 4e6d1cb2...).
It is stated plainly that pv_entity is not a control input and does not change
what the loop does, and that absence publishes `unknown` rather than 0.

THREE CORRECTIONS BELOW THE NEW SECTION, WITHOUT REWRITING HISTORY. The 0.10.1
preamble said SAFETY-56 was open; the SAFETY-57 entry said its accusatory
diagnosis half was "deliberately untouched"; the 0.10.0 preamble left SAFETY-56
with no pointer while SAFETY-57 had one. All three quotations are what the
0.10.1 image actually prints and are left standing - a reader on 0.10.1 has to
recognise them - each now scoped to 0.10.1 and pointed at `## 0.11.0`.

VERIFIED. test_version_gate.py part 11 all four: 11a one contents table and the
slicer closed (302 lines under '0.11.0'), 11b 0.11.0 == config.yaml, 11c all
three RETIRED_PROVIDERS ids named - scoped to a pre-0.10.0 crossing and pointing
at `## 0.10.0`, which is where the evidence is - 11d still exactly one
`## Unreleased` below, PKG-08's, untouched. 31/31 in the CI image, checks.yml's
exact command, purged tree, `:ro`.

Not deployed and not installed. Shipping is a separate pull request from
release/1.0 into master, per docs/RELEASE.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 18:50:13 +02:00
admin 94da37fc72 TEL-11: PV production stops being invisible, and stays out of the control law (#113)
Reviewed on the PR. Green traced to run 825 (PRNUM 113, BASEREF release/1.0, attempt 1, real 8m6s execution). Control-path identity independently reproduced on both trees and counter-tested with a planted leak (red on 26/41 cells); all three of the trace tool substituted refusals fire. M7 genuinely red. Three publication states distinct on the wire. 31/31 in the CI image.

Not deployable as merged: config.yaml stays at 0.10.1, so predeploy_check.py reports a NO-OP until PKG cuts a version.
2026-09-24 15:55:29 +02:00
admin 9f6b9f14cd CI-9 follow-up: the summary said "mechanically", the blind spots say otherwise (#102)
Corrects the preamble's claim that the `guard the trigger` step keeps checks.yml filter-free "mechanically". It does not, for blind spots 1 and 3: the guard lives inside the workflow a filter makes Gitea skip, so for those the defence is the comment.

Names the filter that would actually get written - `branches: [release/1.0]`, not `[main]` - because it reads as tightening onto the protected branch, leaves every day-to-day pull request green, and switches off the `release/1.0` -> `master` release pull request that SEC-2 made the mandated path to an installed system. Points the forge fix at both protected branches, not just `release/1.0`.

Reviewed on the pull request. Verified from the branch's bytes: the guard's awk is unchanged and still refuses `branches:`, `paths:`, `paths-ignore:`, `branches-ignore:`, `tags-ignore:`, `types:` and the inline-flow form injected into the `on:` block of the edited file; comment-only at 0 non-comment changed lines, non-comment lines identical 139 == 139; the merged tree differs from c9aaf7f in this one file only. Green traced per CI-10 to run 824 / job 1949, payload PRNUM 102 / BASEREF release/1.0, base c9aaf7f, 30 PASS 0 FAIL.
2026-09-24 14:37:15 +02:00
admin c9aaf7f04d SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can (#112)
Text only, no behaviour change. Three operator-facing sentences stop asserting a dead register where the gate cannot distinguish a dead register from a pack the BMS is refusing.

Reviewed on the PR: behaviour byte-identical (trace tool sha256 6030175ed2ab reproduced on both trees, plus AST identity with string constants normalised); five mutations re-applied on purged trees, all matching claimed named-red counts; SoC of the live episode independently measured at 11 percent; CI green traced to PRNUM 112 / BASEREF release/1.0.
2026-09-23 21:27:40 +02:00
adminandClaude Opus 5 8a6acd9fa2 SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING,
same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390
capture reads, a 66-cell swept grid, and six driven controller worlds produce
the byte-identical document `6030175e...` on origin/release/1.0 and on this
branch, while the sentences differ.

THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the
register has stopped reporting reality, or the SOURCE cannot comply with the
command - and nothing `freshness.py` is handed separates them. Three sentences
asserted the first. On the live 2026-09-21 episode it was the second: the pack
read 11 % for the whole 850 s hold, every command in that hold was a discharge,
and the register answered the first CHARGE command three seconds later. The
readiness row was worse still, because it asserted a false fact about a NAMED
entity that was present, numeric and updating - so the operator opened
Developer Tools, found it working, and had every reason to conclude the
diagnostics were broken.

THE FIX. Each message states what was OBSERVED and names BOTH explanations.
Three wordings, no shared helper: two are a log line about a behaviour, the
third is a banner about an entity, and a helper serving both would drop
whichever half the other caller does not need. SoC stays STATED, NOT WIRED -
part 11b drives the two worlds at 50 % and 11 % and the sentence does not move
one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()`
already rides `liveness_notes()` a few rows below, so the discriminator is "is
that row there?", and part 11d asserts it is present in one world and absent in
the other.

THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground
truth written down rather than derived from the published stream, asserts they
are really two (40 of 40 reads differ) while the published stream is
bit-identical, and only then grades the sentences. Eleven mutations, all red:
each of the three sentences reverted (3, 2 and 2 named reds), the two
explanations transposed at ZERO bytes (1), the second explanation deleted (1),
the admission of ambiguity replaced by a ranking (1), all three reverted at
once (5), and two aimed at this card's own check - collapsing the world pair
(2) and emptying the accusation list, which a positive control against the
three sentences as 0.10.1 shipped them catches (1).

AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE.
Transposing `label` and `entity` in the row made it unfindable and the run died
on an IndexError - a red with no name and every later check ungraded, FCST-06's
shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3
after. And the first invariance run compared a tree with itself, because it
archived a branch whose edits were not committed yet; the tool now REFUSES to
report "behaviour unchanged" unless the sentences halves differ, and both of
its refusals are driven.

SAFETY-57's part 10h check was the handoff and is inverted rather than deleted:
it required the accusation to still be present so that removing it had to be a
deliberate act. This is that act. Its escape clause is untouched.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 21:02:40 +02:00
admin 239e120bf6 SEC-2: write down the release path, now that master refuses a direct push (#108)
Reviewed on the PR (issuecomments 1480, 1485, 1488, 1489). Documentation only: docs/RELEASE.md (new, 116 lines) plus a 2-line pointer in README.md's file map. No code, no workflow change.

Verified against the forge rather than accepted from the document:
- Both branch_protections rules re-read field-for-field identical (enable_push false, enable_force_push false, status check `checks / unit (pull_request)`, required_approvals 0, block_admin_merge_override true, no whitelists, no file patterns); master's rule created 2026-09-23T03:09:21; default_branch still master. Section 2's After table is exact. No protection was changed by this review - both rules re-read with their original updated_at.
- The empty-PR 405 trap reproduced independently on my own control (throwaway PR #111 between two same-SHA unprotected branches): empty PR -> 405 "Please try again later"; same PR after one commit -> 409 "head out of date". Section 1's "read the message, not the code" is correct and both messages are quoted accurately. PR #111 closed, branches deleted.
- release/1.0 (b0b24e5) is an ancestor of master (0f14c2a), so a literal release PR is empty right now - PR #109 has 0 commits, 0 files, and Gitea opened it anyway. Section 1's closing note is right.
- A master-base PR gets a genuine CI run, not a laundered skip: PR #107 head cb7e45b3 shows Waiting -> In progress -> success, "Successful in 7m56s", run 814. This PR's own head 9d593429 likewise, run 818.
- All five required steps are present and correctly ordered: work merges to release/1.0 with a version bump in goodwe_controller/config.yaml; release via PR release/1.0 -> master; direct push refused; green check before merge; `ha store reload` after, without which the Supervisor keeps serving the cached version. required_approvals: 0 is stated twice, so no reader can believe the dev/review split is enforced.

One non-blocking defect left open (issuecomment 1485): section 1 calls 0f14c2a "the only commit on master that carries no (#NN) merge suffix". 274 of master's 297 commits carry no suffix. The true statement is stronger - no release has ever reached master through a pull request, and 6f5e8e3 (0.10.0) was promoted by the same direct push one release earlier, so 0.10.1 was the second, not a one-off. Background, not procedure; wants a follow-up line change.

A third comment of mine (issuecomment 1488, merge style) is withdrawn in issuecomment 1489 - it rested on a premise I had not checked and which is false.
2026-09-23 04:08:18 +02:00
admin b0b24e5d41 PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0 (#105)
checks / unit (pull_request) Successful in 7m57s
Reviewed on the PR (issuecomments 1455-1462): identity verified unchanged (slug goodwe_controller, no image: key, installed slug 68285ac7_goodwe_controller corroborated from HA backup metadata); version-gate 11a-11d re-implemented and verified independently; the 16-of-93-at-790s pairing re-derived from the committed 16-day capture (>=710: 17, >=790: 16, >=815: 15); the SAFETY-57 entry verified as a faithful move carrying only the three declared #104 documentation fixes; corrected 0.10.0 preamble corroborated to the day against backup metadata; suite 30/30 reproduced with checks.yml's exact command. Two files, no control code. The 710 s/790 s split between test_freshness.py and this file is a known, stated gap and takes its own card.

NOTE: master (the Supervisor's default branch) is still 0.10.0 and still lacks SAFETY-57. This merge does not deliver; bringing master to release/1.0 is a fast-forward and is the remaining step.
2026-09-22 15:52:25 +02:00
admin b9f7bd0506 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested (#104)
Reviewed and merged by the PR review agent. Acceptance criterion re-driven independently off the committed RS-485 capture: the verdict is withdrawn with 0x0518 held constant at -3 W, no external change. Counterfactual release_s=inf verified byte-equivalent to the shipped-before module over 242336 reads, so the SAFETY-37 conjunction is untouched. 30/30 suite green in checks.yml's own image; 11 mutations re-applied on a purged tree; the argued-equivalent M7 proved equivalent over full internal state.

Three non-blocking documentation findings filed on the PR (comments 3/7, 4/7, 5/7) for a follow-up before the next version is cut.
2026-09-21 15:49:35 +02:00
adminandClaude Opus 5 43c144b8d9 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.

REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:

  10:51:24.7  0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
              the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
  10:51:29.7  the command reaches +1060 W - 800 W of travel
  10:52:00    the conjunction arms. Inverter.batt becomes None
  10:52:21.7  the site commands 0 W, on the wire
  ...         0x0518 does not change value for 850.0 s. The setpoint does not
              change value for 790.0 s. The house exports 2.4 kW throughout
  ~11:04      a human restarts the add-on. That is what ends it

AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.

THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.

THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:

  the verdict is withdrawn when the obligation that produced it has been gone
  for RELEASE_S, and the register is then re-graded from scratch.

RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.

The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.

WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.

Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.

main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.

Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-21 12:33:56 +02:00
adminandClaude Opus 5 6f5e8e378a PKG-15: bring release/1.0 to master at 0.10.0, so the default branch is the add-on
`master` has been `5184a2c` / v0.2.1 since 2026-08-25 - the tree that drives the
house - while every ticket since has landed on `release/1.0`. Three consequences
were live, and all three are what this merge closes:

 * `master` is the DEFAULT branch, so Gitea indexes dispatchable workflows from
   it. `master` had no `.gitea/` at all, which is why `GET /actions/workflows`
   answered empty and the UI's dispatch button was missing.
 * new pull requests default to `master`. #102 was opened against it by
   accident and its first run graded the change merged into a stale `master` -
   an honest-looking green answering the wrong question.
 * AND THE ONE THAT NOW MATTERS MOST: the repository has not yet been added to
   Home Assistant, and adding it is part of this release. `master` is the
   branch the Supervisor will read the moment it is added, so whatever stands
   here is what it shows and offers to install. This merge is what makes that
   0.10.0 rather than 0.2.1.

NO CONFLICT WAS POSSIBLE AND THAT WAS CHECKED, NOT ASSUMED. `master` is a
direct ancestor of `release/1.0` (`git merge-base --is-ancestor` true), the
merge base IS `5184a2c`, and `origin/release/1.0..origin/master` is empty -
`master` carries nothing `release/1.0` lacks. `--no-ff` is used anyway, so the
crossing from 0.2.1 to 0.10.0 is one addressable commit rather than a pointer
move.

WHAT CROSSES: config.yaml 0.2.1 -> 0.10.0. The add-on the Supervisor will build
is a different program from v0.2.1 in the ways `goodwe_controller/CHANGELOG.md`
sections 0.3.0 through 0.10.0 describe - among them P1 meter ingestion, the
separate integrator the velocity form did not have, shadow mode, the tariff
plan and the multi-inverter roster. The ROLLBACK POINT does not move: tag
`v0.2.1` still names `5184a2c` and still names the tree that ran the house.

NOT A DEPLOY. Nothing is installed, no `ha addons update` is run, `/addons/` is
untouched and neither 192.168.2.158 nor 192.168.2.221 was contacted. Adding the
repository to Home Assistant, and pressing Install, remain the owner's call.

Verified before merging: the full suite in the CI image on `release/1.0`'s tree
- `cp -a`, purged, `:ro` mount, one file at a time, exactly the command in
.gitea/workflows/checks.yml - 30/30, exit 0; and PR #103's own
`checks / unit (pull_request)` was a real `success` on the merge, not a skip.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-20 12:34:30 +02:00
admin 8a5736136a PKG-15: fold TEL-10 and SAFETY-48 into 0.10.0, so the version names its contents (#103)
Reviewed and merged by the PKG-15 review agent.

Verified rather than accepted:
- test_version_gate.py 11d pins `## Unreleased` blocks below the newest section at exactly one; deleting the block goes red (reproduced on a copy of the tree).
- 32 runtime commits since 86bdf49 and 24 accounted by the contents table, re-derived with predeploy_check.py's own RUNTIME rule; PKG-14's superseded 28/21 were correct when taken.
- app/validate.py imports neither main nor mqtt (read by AST), and SLEW_RAIL_FRAC / LOOP_TICK_S / PLANT_SETTLE_S are byte-identical across cb3f686..HEAD, so PKG-14's CLEARED transcript still holds.
- CI-9 (16b1d6c) touches only .gitea/workflows/checks.yml, outside the built image and outside RUNTIME.
- The SAFETY-48 entry keeps the capacity-tariff misreading out: no worst-quarter row in the A/B table, and the 3739 -> 3434 W figure appears only inside the paragraph that disclaims it.

Three non-blocking defects posted on the PR: the gain:0.3 / slew-rail tie values are swapped against DECISIONS/SAFETY-48; "touch three files between them" should say three runtime files; and the stated reason cb3f686 enters the count ("last..HEAD excluded it") is wrong, though the count is right.
2026-09-19 19:08:05 +02:00
adminandClaude Opus 5 5aba220046 PKG-15: fold TEL-10 and SAFETY-48 into 0.10.0, so the version names its contents
checks / unit (pull_request) Successful in 7m53s
0.10.0 was cut by PKG-14 on 2026-09-16 and three tickets have merged into
release/1.0 since. Two of them change the built image - one is a CONTROL LAW
change and one adds three MQTT entities - and neither is described anywhere in
this file. Tagging that tree today would stamp a number on contents the
changelog does not account for.

FOLDED RATHER THAN CUT AS 0.11.0, AND THE ARGUMENT IS CONDITIONAL.
0.10.0 has never been built or pulled anywhere: the reference install is on
0.7.0 (PKG-14's own predeploy run records `deployed on the box : 0.7.0`), the
repository carries exactly one tag, `v0.2.1`, and no release. So the string
`0.10.0` does not yet name a tree anyone is running, and the PKG-06/PKG-07
no-op that forbade re-cutting `0.9.0` does not reach it. Cutting 0.11.0 would
burn a number on a release that never left the repository. The condition is
checkable and the section now says so: run against a box already reporting
0.10.0, `tools/predeploy_check.py` refuses with THE DEPLOY WOULD BE A NO-OP and
names the runtime commits since the bump. `config.yaml` stays at 0.10.0, so
`test_version_gate.py` 11b still finds the two sides equal.

SAFETY-48 IS THE ENTRY THAT MATTERED MOST TO GET RIGHT, AND WHAT IT PROMISES
IS LESS EXPORT - NOT A LOWER BILL. The measured result is export 39.61 -> 34.07
kWh over the committed 16-day replay, 14 % of the replayed figure, falling at
every plant and tuning variant swept (~4 % to ~16 %, median near an eighth).
The section says in its own heading and its first line that the control law
changed, and it says PLAINLY that the billed quarter is not a claim: at every
plant lag <= 5.0 s - including the one that best reproduces the recorded export
- release/1.0's worst quarter is ALREADY 3434 W and this changes it by exactly
zero. The 3739 -> 3434 W headline exists at the single longest fitted lag, and
the lag is not identified by the recording. The costs are in the entry too: the
cap moves a saturation-frozen integrator on 1095 of 79 160 frozen ticks, 679 of
them outward; SAFETY-13's settle values moved; SAFETY-39's "the slew does not
own the over-absorption" is now false.

TEL-10 gets the three site rows, what each one is, and the two things a reader
would otherwise get wrong: the lead is NOT a subtraction of two published rows,
and `Loop reason` is not the `Why` row. It repeats neither of the two sentences
TEL-10's own review retracted - EIGHT messages stay first and the ninth,
`goodwe_ctl/availability`, is byte-identical but deliberately moves to last.

CI-9 IS DELIBERATELY NOT IN THIS FILE, AND THE OMISSION IS WRITTEN DOWN RATHER
THAN SILENT. It changes one file, `.gitea/workflows/checks.yml`, outside
`goodwe_controller/` entirely: not in the built image, not in `is_runtime()`'s
list, and not observable on any version of the add-on. This file is the release
note the Supervisor shows beside the version number, and a row here has to be
something the person deciding whether to press Update could act on. The note
above SAFETY-48 says so and says the rule is about audience, not importance.

THE STRAY `## Unreleased` AT LINE 1777 IS NOT TOUCHED, AND THAT IS A DECISION.
It is the 0.8.0-era block PKG-14 annotated: every row in it has shipped, the
annotation says which release each went to, and re-filing it is PKG-08's card.
It is also load-bearing - `test_version_gate.py` 11d pins the count of
`## Unreleased` blocks below the newest section at EXACTLY one, so deleting it
is red on the commit that does it, and so is adding a second.

TWO MEASURED FIGURES IN PKG-14'S PROSE WENT STALE AND ARE RE-DERIVED, NOT
ADJUSTED. The runtime-commit count since `86bdf49` is now 32, not 28, of which
the contents table accounts for 24, not 21; both re-run through
`predeploy_check.is_runtime()` itself. The other eight are the three misfiled
tickets (SAFETY-43 x2, SAFETY-44 x3, TEST-21 x2) and `cb3f686`, PKG-14's own
bump, which edits `config.yaml` and so counts as runtime - it was HEAD when
PKG-14 measured and is inside the range now.

PKG-14's `CLEARED, exit 0` predeploy transcript was NOT re-run and now carries
the check that says why it still holds: `config.yaml` is untouched by both
tickets; `app/validate.py` imports neither `main` nor `mqtt`, and the three
names it takes from `control` - SLEW_RAIL_FRAC, LOOP_TICK_S, PLANT_SETTLE_S -
are byte-identical across cb3f686..HEAD.

Verified: the full suite in the CI image, `cp -a` of the tree, purged, `:ro`
mount, one file at a time, exactly the command in .gitea/workflows/checks.yml -
30/30, exit 0. No runtime file is in this diff.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 18:49:09 +02:00
admin 16b1d6c422 CI-9: a stacked PR is skipped, and a skipped check clears the merge gate (#95) 2026-09-19 14:55:12 +02:00
adminandClaude Opus 5 ca8fd01819 CI-9: correct the guard comment's grading claim, and name the third blind spot
checks / unit (pull_request) Successful in 7m54s
Documentation only - no change to the guard, the trigger, or any step.

The guard's comment block contradicted itself. It said the pull request that
reintroduces a filter "is still graded by the unfiltered workflow which is on
the base today", while the checkout step's note a few lines below says grading
uses the HEAD's workflow. The head's is correct, and the review measured it on
PR #101: head carrying a filter that excludes the base, base carrying the
unfiltered workflow -> no run, context posted `skipped`, rollup `success`, gate
cleared (409). The wrong version made the step sound like an unconditional
ratchet. What is actually true is narrower: it bites whenever the reintroduced
filter still names the pull request's own base, which is the ordinary case.

That correction exposes a third blind spot, worse than the two already listed.
A reintroduced `branches:` filter that simply does not name the base escapes
the guard entirely, because the pull request carrying it is itself skipped. It
needs no craft - `branches: [main]` from a template, or a tidy-up to `[master]`,
which nothing in this repository's history has ever targeted - and it lands as a
skipped, laundered, untested merge into release/1.0. After that every subsequent
pull request is skipped as well: the gate off completely, not merely the stacked
case leaking.

It is documented, not fixed, and deliberately so. No in-repo guard can close it,
because any such guard lives inside the workflow that gets skipped. Closing it
needs a second permanently unfiltered workflow whose context is added to
release/1.0's `status_check_contexts` - a forge change, the owner's decision,
being put to them separately, and explicitly not a blocker on CI-9.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 14:44:16 +02:00
adminandClaude Opus 5 d2ad080e45 CI-9: guard the trigger mechanically, and re-derive two figures I made up
checks / unit (pull_request) Successful in 7m55s
Review findings on PR #95.

1. Two figures in the header were written under the word "measured" and were
   not measured. "of the 50 pull requests in this repository's history, 49..."
   came from a /pulls call I did not notice was truncated at Gitea's 50-item
   page cap; and "#93 was stacked on TEL-10 five days ago" was invented - #93
   was created 2026-09-19T10:05:00 and merged 11:05:26, the same morning, under
   three hours before CI-9 was opened. Both re-derived from a paged API query
   and now stated with their denominator: 93 pull requests predate this ticket
   (#1..#93, excluding CI-9's own #94..#98), 92 against release/1.0, exactly one
   stacked (#2, TEL-01 -> SAFETY-04). The 92 is flagged as an upper bound rather
   than a census, because the API reports a pull request's CURRENT base and so
   hides any that was opened stacked and later retargeted - which is #93 itself.
   The ratio, and so the cost argument, is unchanged.

2. The fix rested on an invariant - checks.yml has no event filter - that was
   defended only by a comment. Prose has already failed in this exact file:
   9c1a23328a shipped "NO `paths:` FILTER, AND ITS ABSENCE IS LOAD-BEARING" and
   `branches: [release/1.0, master]` in the same commit, eighteen lines apart,
   and that survived 20 days and 84 merges. Adds a step that reads the `on:`
   block of the MERGED checks.yml and fails if it has regained a `branches:`,
   `paths:`, `tags:`, `types:` or any `-ignore` variant. This is not the card's
   option 3 - it does not try to detect its own skip, which is impossible; it
   bites on the pull request that reintroduces a filter, which the unfiltered
   workflow still grades. Two blind spots are named in the step's comment, both
   needing a protection-rule change that is the owner's call.

Also softens "uncloseable from here", which the review judged overstated:
Gitea's acceptance of a `skipped` context is unreachable from this repository,
but the consequence is substantially closeable, and the guard is what closes it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 14:25:22 +02:00
adminandClaude Opus 5 074157c4c2 CI-9: drop the pull_request branches filter, because a skipped check clears the gate
checks / unit (pull_request) Successful in 7m57s
`branches: [release/1.0, master]` meant a stacked pull request - one based on
another feature branch - never matched. Gitea does not stay silent about a
workflow it sits out: it posts the required context itself with state
`skipped`, the combined-status rollup reports that as `success`, and the merge
gate accepts it. Retargeting does not repair it, because the skip is a commit
status on the head sha and so survives the base change.

Measured on Gitea 1.27.3 with throwaway PR #94 against a branch carrying a copy
of release/1.0's protection rule:

  only status is `skipped`   ->  POST .../merge  409 head out of date  (CLEARED)
  no status at all           ->  POST .../merge  405 not all required  (refused)
  status `pending`           ->  POST .../merge  405 not all required  (refused)
  status `success`           ->  POST .../merge  409 head out of date  (CLEARED)

The 409s come from a deliberately wrong head_commit_id in the probe, which
Gitea checks only after branch protection - so a 409 means the request had
already cleared the gate, and nothing was ever merged. `skipped` is the only
state that leaks.

Fixing this at the gate is not possible. Gitea branch protection can require
that a context is PRESENT, never that it is SUCCESS: its whole status-check
vocabulary is `enable_status_check` and `status_check_contexts`, per this
server's own /swagger.v1.json. So the fix has to be upstream - never emit a
skip - which means no event filter.

Cost: every pull request now runs the full ~8 minute suite, including the
intermediate steps of a stack. 49 of the 50 pull requests in this repository's
history were opened straight against release/1.0 and would have run anyway.

Also corrects two things CI-01's header stated as fact. A filter miss is
fail-OPEN, not the fail-closed pending-forever it described; and it is a
skip-ci keyword, not a filter miss, that actually withholds the context and
leaves it pending.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 13:58:58 +02:00
adminandClaude Opus 5 186a044a3a Merge pull request 'SAFETY-48: the slew step ceiling reaches the integrator, and what it bounds is the LEAD' (#93) from SAFETY-48 into release/1.0
Reviewed on the pull request and merged there. Retargeted from TEL-10 to release/1.0 after #92 merged, and NOT merged on the inherited green: retargeting alone left the old `skipped` conclusion attached to a6af332 and the combined status still read success, so the required context was satisfied by a workflow that had never run. Run 799 is a genuine pull_request execution on the merge into release/1.0 - all five steps, the add-on's own tests occupying 08:56:58 to 09:04:47 UTC.

THE CAP MOVING A SATURATION-FROZEN INTEGRATOR IS ACCEPTABLE, NOT MERELY DISCLOSED. The disclosed figures reproduce exactly against the committed capture - 79 160 frozen ticks, 1095 moved, 679 further out on the side they were already on, worst 2424 W - and the worked tick in the comment is present with exactly the numbers written down and is the worst of that subset. What decides it is where the integrator lands rather than which way it moves: on the shipped configuration integrator_max_w is unset, so target == i_w after the bounds and the cap holds |i_w - slewed| to one slew step on every slew-limited cycle, frozen ones included. Measured over the whole 256 251-tick recording the carried integrator never stands more than two slew steps from the command on the wire - 800 W against release/1.0's 9200 W. On the frozen path this replaces an integrator bounded only by integrator_max_w with one bounded at two steps, so the loop is less wound up on those ticks and not more. The same-cycle command cannot be affected at all, the cap moving i_w after slewed is decided.

THE ALTERNATIVE IS REFUSED FOR A MEASURED REASON. Gating the cap with `if frozen: _lead_cap = float("inf")` reproduces all four of section 5's corrected figures - export 34.71 kWh, wasted 3.49 kWh, worst quarter 3434 W, worst observed lead 4961 W. The gate does leave the bound with a hole large enough to make the card pointless.

NOTHING FALSE FOUND. Section 3a's lag table reproduces cell for cell, including the rows that say the peak improvement is absent at every lag at or below 5.0 s; the card does not claim a capacity-tariff benefit and says so in four places. Form A is committed nowhere, so it was rebuilt from section 3's prose alone and reproduces all seven figures - 34.43 / 110.62 / 2656 / 2.99 / 3934.59 / +2.73 / +991.53 - which makes section 3 a specification rather than a summary. The one-sided cap was swept against the two-sided band over 136 080 states on an independent grid: 0 differences, corroborating habit 22's retraction.

MUTATION EVIDENCE RE-DRIVEN, EVERY COUNT EXACT, on purged cp -a trees one file at a time: L2 zero bytes 4+3, L4 one red in test_telemetry with test_control GREEN as claimed, L5a zero bytes 5+5, L6 zero bytes 6+3.

SUITE RE-RUN BY THE REVIEWER on the merge rather than the branch tip: release/1.0 29/29, this merge 30/30, exit 0.

One non-blocking note left on the pull request: "worst case 2424 W" is scoped to the 679 further-out ticks, while the largest move over all 1095 is 4220 W. That case is benign - the cap pulling a stale positive integrator down to follow a charging command, magnitude falling - which is why it is a note and not a finding.

Merging is not deploying. The live install still runs release/1.0's control law and slew_w 400 applied by hand; this merge authorises no deploy.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 11:05:25 +02:00
adminandClaude Opus 5 660d079bf3 Merge pull request 'TEL-10: the loop's integrator stops being invisible' (#92) from TEL-10 into release/1.0
Reviewed on the pull request and merged there. `checks / unit (pull_request)` run 798 is a real execution, not a skip: all five steps ran and "the add-on's own tests" occupied 08:04:51 to 08:12:38 UTC.

CONTROL BEHAVIOUR IS UNCHANGED, VERIFIED MECHANICALLY RATHER THAN READ. goodwe_controller/app/control.py is blob 180f58a on release/1.0 and on TEL-10 alike, same sha256 of contents, and release/1.0 is a direct ancestor of TEL-10 so there is no merge-base divergence for a change to hide behind. The only executable edit inside cycle() is prev_w=self.target becoming a named local, loop_prev, passed to the same call. Three write sites for self.i_w exist and only two have a telemetry counterpart; the third is the arbiter re-seed at main.py:3049, inside the same branch and immediately followed by compute(), so it cannot leave loop_i_w stale. app/mqtt.py appends to SENSORS and discovery_payloads() walks it in order, so every existing entity keeps its index.

SUITE RE-RUN BY THE REVIEWER, on the MERGE rather than the branch tip, in the CI image on a purged tree, :ro, one file at a time: release/1.0 29/29, this merge 30/30, and the stacked SAFETY-48 30/30 against both bases. All exit 0.

MUTATION EVIDENCE RE-DRIVEN RATHER THAN READ, because the previous round's counts were irreproducible. M1 is 5 reds on TEL-10's tree and 4 on SAFETY-48's, exactly as the header says and for the reason it gives; M2 is confirmed GREEN and is reported as a survivor; M7 is -96 B and 10 reds in test_mqtt.py plus 1 in test_telemetry.py; M9 is a zero-byte reordering and 7 reds. Every claimed count exact.

R6's correction is true and not merely made: part 1's headline now says EIGHT and the slice under it asserts eight entity configs, part 3's NINE headline is backed by a full missing/changed diff that does cover all nine, and the unasked-for fix two lines down reads eight against the eight-prefix slice.

Merging is not deploying. Nothing here reached the inverter and no deploy is authorised by this merge.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 10:54:02 +02:00
admin 68c5ede7b9 Merge pull request 'PKG-14: cut 0.10.0, so fifteen merged tickets can reach an install' (#91) from PKG-14 into release/1.0
config.yaml said 0.9.0 while the live box runs 0.7.0 with 0.7.0's files, so it has never received 0.8.0 or 0.9.0 either. 28 runtime commits had landed since the 0.9.0 bump at 86bdf49 with no version to carry them.

MINOR, AND NOT BECAUSE OF THE NUMBER OF TICKETS. A config that is legal on 0.9.0 is REFUSED on 0.10.0: TARIFF-07 retires three price_provider ids and refuses them by name at startup (the ids stay in the schema enum precisely so validate.py's message is reachable rather than an opaque Supervisor rejection); TARIFF-18 moves price_taxes_eur_kwh 0.06 -> 0.11736, and the non-obvious half is the refusal that deliberately does NOT happen, because SUPERSEDED_TAXES_DEFAULTS_EUR_KWH keeps a taxes period table beside a stored 0.06 from becoming exit 78 on upgrade, with the rung measured un-weakened against a genuinely custom 0.1198; SAFETY-10 adds shadow_mode shipped `auto`, where an existing controlling install does not change by one watt and a fresh install comes up observing.

AND A 0.7.0 INSTALL CROSSES 0.8.0 ON THE WAY. `ha addons update` does not walk versions, so 0.8.0's rule 10 lands at the same moment: an explicit slew_w above SLEW_RAIL_FRAC x rail is refused, and 0.7.0's OWN shipped default of 1000 is refused against a 555.6 W ceiling. Measured red on this tree, with slew_w 400 measured green - which is what the live box carries. Someone reading only the newest section would otherwise miss the one release that can stop the add-on starting.

THE BOUNDARY WAS DRAWN HONESTLY RATHER THAN TIDILY. All 18 table rows in the top block merged after 86bdf49 - verified per row with git merge-base --is-ancestor - so the block is genuinely this run's work and was retitled as-is with its 18 `_this branch_` placeholders resolved to merge shas. But 0.10.0 ships MORE than that table lists: SAFETY-43 and TEST-21 are documented in a SECOND `## Unreleased` block sitting below 0.9.0, and SAFETY-44 - which changed app/main.py and app/store.py - is in CHANGELOG.md NOWHERE AT ALL. All three are named in the 0.10.0 preamble rather than moved, because re-filing is PKG-08. The second block is annotated, not rewritten or emptied: UX-02 in it shipped in 0.9.0 and is already in 0.9.0's own contents table, while the other three shipped here. Verified independently before merge: all 30 changelog deletions fall inside `## Unreleased` blocks and none in a released section.

THE BLOCK'S OWN STATED REASON FOR THE VERSION CHOICE WAS WRONG AND THE SECTION SAYS SO. It said the number depended on whether 0.9.0's image had been built and pulled, and that if it had not, this work belonged inside 0.9.0. That was written before 0.9.0's section was cut. It has been cut since 86bdf49 with 28 runtime commits behind it, so reusing 0.9.0 would make one version string name two different trees - and the Supervisor keys the built image on exactly that string, which is the PKG-06/07 no-op in its worst form.

Evidence: 29/29 green. predeploy_check.py --deployed-version 0.7.0 --options <live blob> clears at exit 0 both before and after, unchanged but for the shipped version line. No default was touched, so test_defaults_pin, test_price's mirror and test_version_gate stay green for the right reason. Eight mutations, no survivors, one at zero bytes. One was a SURVIVOR on the first draft - the slicer control was a sentinel only an EOF-running slicer could reach, so deleting a heading never got there; it asserts an invariant now, exactly one contents table per section.

Card numbers that did not reproduce, corrected in the report: the block is 1541 lines citing 31 ids rather than 5487 citing ~70 (those figures fit the whole file and the Detail notes block, which is PKG-08's subject); 28 runtime commits rather than 30; 18 tickets rather than fifteen. FCST-04 has a table row but no section body - pre-existing, left alone.
2026-09-16 02:58:28 +02:00
adminandClaude Opus 5 cb3f686555 PKG-14: cut 0.10.0, and say what an upgrade from 0.7.0 crosses
checks / unit (pull_request) Successful in 7m51s
`config.yaml` 0.9.0 -> 0.10.0, and the top `## Unreleased` block is closed
into `## 0.10.0` with a preamble that names the backward-incompatible
changes and who they reach.

MINOR, and NOT because eighteen tickets landed. A stored options blob the
previous version started on is REFUSED on this one:

  * TARIFF-07 retires three `price_provider` ids; a site set to one is
    refused BY NAME at startup. Measured on the reference blob, with a
    control on an accepted id so the refusals are about the ID.
  * TARIFF-18 moves `price_taxes_eur_kwh` 0.06 -> 0.11736. A site that
    STORED 0.06 is untouched, and - the non-obvious half - a taxes period
    table beside that stored 0.06 does NOT become a startup refusal on
    upgrade, because `SUPERSEDED_TAXES_DEFAULTS_EUR_KWH` reads it as
    untouched. Measured, with the counterfactual that the rung is not
    weakened (ORES's 0.1198 is still refused).
  * SAFETY-10 adds `shadow_mode`, shipped `auto`. An existing CONTROLLING
    install does not change by one watt and a FRESH one comes up observing.
    Measured cross-revision, 8f82dd4 -> e6da478, same stimulus through the
    shipped `Controller.cycle()`: byte-identical write streams, 13/13/25
    writes. Positive control: the same driver at `shadow_mode: on` gets 13
    writes to 5000 W on the older tree and one 0 W write on the newer.

And the one a reader of the newest section alone would miss: `ha addons
update` does not walk the versions, so a 0.7.0 install meets 0.8.0's and
0.9.0's rules at the same moment as 0.10.0's. Of those, SAFETY-39's rule 10
refuses 0.7.0's OWN shipped default `slew_w: 1000` against a 555.6 W
ceiling on a 5000 W rail. Measured red on this tree; the reference
install's `slew_w: 400` is measured green.

SCOPE, and it is drawn honestly rather than tidily. The top block's 18
entries all merged after the 0.9.0 bump `86bdf49`, so the block is closed
as-is and its `_this branch_` placeholders are resolved to merge shas.
⚠️ 0.10.0 SHIPS THREE MORE RUNTIME TICKETS THAT ARE NOT IN THAT TABLE -
SAFETY-43, TEST-21 and SAFETY-44 - and they are NAMED in the preamble
rather than moved, because re-filing this file's misplaced entries is
PKG-08. SAFETY-44 (`app/main.py`, `app/store.py`) is in the changelog
nowhere at all; that is said in both places. The second `## Unreleased`
block below `## 0.9.0` is ANNOTATED, not rewritten or emptied - UX-02 in it
shipped in 0.9.0, the other three in 0.10.0. No released section is
rewritten.

`test_version_gate.py` gains part 11: the bump and the closed section are
one act. PKG-09 refuses a deploy whose version did not move; nothing graded
the mirror failure, in which the version moves and the block is never
closed. Two sides from two files, a slicer with a synthetic positive
control run on every invocation, the retired ids read off `app/price.py` by
AST rather than transcribed, and the count of still-misfiled blocks frozen
so it can only shrink.

Mutations, all purged, tree bind-mounted :ro, backups at mktemp paths and
the revert fingerprinted:

  M1  `## 0.10.0` -> `## Unreleased`       +4 B    RED 2
  M2  version 0.10.0 -> 0.10.1             +0 B    RED 1   (ZERO-BYTE)
  M3  an id stripped from the NEWEST       +10 B   RED 1
      section only, left below
  M4  a 4th retired provider in price.py   +62 B   RED 1 here, 4 in
                                                   test_price.py
  M5  `## 0.9.0` heading lost              -3 B    RED 1
  M6  a 2nd `## Unreleased` left standing  +27 B   RED 1
  M7  the slicer never closes              -32 B   RED 3
  M8  SUPERSEDED_TAXES... emptied          -5 B    RED 2 on the evidence
                                                   instrument, plus
                                                   test_validate/test_price

⚠️ M5 WAS A SURVIVOR ON THE FIRST DRAFT. The slicer control was a sentinel
(`## 0.8.0`) that only a slicer running to EOF could reach, and deleting one
heading never gets there - ARCH-02's fifteenth instance, in a fresh costume.
11a now asserts the invariant instead: exactly one contents table per
section, which is what a lost heading breaks.

29/29 test files green. `tools/predeploy_check.py --deployed-version 0.7.0
--options <live blob>` CLEARED, exit 0, before and after.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-16 02:48:27 +02:00
admin 587495e143 Merge pull request 'SAFETY-47: say what a shadow run can and cannot show' (#90) from SAFETY-47 into release/1.0
DOCS.md, app/shadow.py's header and DECISIONS/SAFETY-10 all claimed the strategies ask for a fixed power from inputs that do not depend on what the battery did, so a shadow run shows you the real trades. That was true when shadow mode was designed and false by the time it merged: SAFETY-45 landed hours earlier and made the buy leg min(asked, headroom), where headroom = (900/remaining) x (ceiling - projected) and `projected` reads the open quarter's accumulator - the meter, which is exactly a function of what the battery did. The strategy became closed-loop and the exemption went stale.

Measured at a binding cap, 1500/1200/2000, the same hour twice: live grid 1224-1506 W held at the ceiling against a flat 1200 W in shadow; SoC 50.000019 -> 51.856789 % against 50.000000 -> 50.000000; the two runs differ on 716 of 720 cycles; the final recorded figure is -302.4 W live against -2000.0 W in shadow, 6.61x. On a SAFETY-45-reverted tree the limit cycle is 28 onsets live against 1, guard engaged 410/720 against 0/720. Two of the three defects the card cites as motivation are closed-loop phenomena shadow cannot exhibit; TARIFF-14's half genuinely is visible, hour and price and spread identical 720/720.

THE CAVEAT'S DIRECTION WAS MEASURED RATHER THAN WRITTEN, and the ticket had it wrong. A draft saying a live run reaches a SMALLER number was checked pairwise over 3600 charging cycles in five configurations: the shadow record is never below live - zero cycles below and 730 EXACTLY EQUAL, at the start of each quarter where the amplification is 1.0. `Smaller` would have been false on 730 rows. The shipped sentence says UPPER BOUND and the two-point arithmetic behind it is graded.

Caveated rather than re-computed, with the rejections recorded: re-computing would make the recorded decision no longer the decision the shipped path reached while arbiter, clamp, the SAFETY-28 gate, the log and MQTT all ran on the real one - a second controller everywhere except the wire; recording nothing blanks the row exactly when arbitrage trades, and the log's edge key IS the watts; recording the unsized ask beside it adds a second number with no warning, and at the shipped 3500/2000 both read 2000 W. The trap avoided: keying the caveat on `capped` would fire at the quarter's START, where the record is right, and go SILENT at the end, where it is 6.61x out. It keys on the headroom having been MEASURED.

AND THE TICKET'S OWN ANALYSIS WAS INCOMPLETE. I said the committed evidence table could not fail for two reasons. They are independent in the FIX direction too: widening the fixture to a binding cap still leaves the comparison passing, because it reads index zero and the first charging cycle is -300.0000 W in both runs. Fixing only the fixture closes nothing. Recorded in MUTATION.md as a new habit-4 shape - an INDEX, not a fixture - and the agreement at index zero is now graded as an expectation so nobody rebuilds on it.

Evidence: 29/29 green. Fourteen mutations, no survivors. One was a REAL survivor first - deleting the caveat from the action log left all 29 files green, because the sentence was an f-string in _shadow_settle() and the only suite that drives it runs with meter_source: off; it is shadow.log_line() now. One CORRECTLY survived and is reported as such: min -> max makes the record larger, which is still an upper bound, so it is not the inversion that matters. And the new section nearly shipped FCST-06's shape - a mutation made it raise on its first min() and report zero reds - so every check now carries the section's precondition.

Two design limits stated rather than smoothed: the caveat discloses but does not help, since an engineer still cannot obtain the real number without arming the battery - the fix for that is a rig mode replaying the site's own captured meter through the shipped decision path, filed separately and deliberately NOT by giving shadow mode a plant model, which is the one change that would break its safety argument. And SAFETY-10's takeaway still oversells `auto`, which this card did not rewrite.
2026-09-15 01:36:41 +02:00
admin e6da478f87 Merge pull request 'SAFETY-10: shadow mode, and 0 W is a number rather than a silence' (#89) from SAFETY-10 into release/1.0
The closed-loop rig made the case for this: with arbitrage armed and a binding cap the loop ran 28 charge onsets an hour (SAFETY-45); the price lookup returned the wrong quarter-hour for 45 minutes in every 60 (TARIFF-14); the SoC ceiling churns 598 Wh to gain 310 (SAFETY-46). Every one was invisible from outside, and there was no way to watch what the optimiser WOULD do without letting it do it.

THE TICKET SAID DEFAULT-ON AND THE AGENT REFUSED IT, correctly. The Supervisor resolves options as {**config.yaml defaults, **stored user options}, so a NEW key with a new default reaches every EXISTING install on the next update - including the one regulating the author's battery. `shadow_mode: true` would have stopped it silently, and the only symptom would be a battery that stopped doing anything. There is no mechanism by which one key defaults differently for a new install and an existing one - `options:` IS the default and there is one of it.

So the default is a value the add-on RESOLVES: shadow_mode: list(auto|on|off), shipped `auto` = shadow while control is STOPPED, live once STARTED. A fresh install ships auto_start: false, so it comes up in shadow and observes before it ever commands - default-on delivered where it is safe. An existing install that is controlling does not change by one watt; verified before merge, `auto` resolves to `not control_started`.

SECOND PUSHBACK, ALSO RIGHT: commands nothing is a NUMBER, not a silence. The inverter holds its last command forever, so a shadow mode that stopped writing would leave whatever was standing STANDING, under a page saying nothing is commanded - the exact looks-healthy-but-is-inert failure this repo keeps finding - and would hold the ESP32's 30 s stale-input watchdog tripped for the whole run, an alarm used as a mode. The actuator is held at 0.0 W, refreshed on the ordinary heartbeat, by the ordinary single writer, as a substitution inside the existing single choke point. Not a second write path. It is the LAST substitution, below SAFETY-28's gate and SAFETY-03's clamp, so both still grade the number the decision produced.

Every failsafe's behaviour is decided and recorded rather than inherited. The sign watchdogs are INERT because they grade standing_w(), held at 0 W - feeding them the decision would have them disagree with a meter that never saw it and LATCH A TRIP SURVIVING INTO LIVE OPERATION AND A RESTART. Clamp, write gate, meter freeze and peak guard OBSERVE the real decision. Circulation and delivery may legitimately latch, because their evidence is measured power. The operator stop is enforced at the wire rather than as a P_SAFETY claim, which would make every recorded decision read `stopped`. A standing latch is named in the shadow banner and turns it red.

Graded on the writes and the rendered surface, never on the flag, with the precondition asserted first: the same stimulus at `off` produces 30 non-zero writes with a largest of 5000 W; at `on`, set(writes) == {0.0} and 26 of them. Closed loop over the same hour twice: live -2000 W throughout, SoC 50.000 -> 62.331 %, grid to 2350 W; shadow 0 W throughout, SoC 50.0 -> 50.0 exactly, grid = the house exactly - with the arbitrage decision identical in action, instant, signed power, reason verbatim and arbiter winner across 3600/3600 samples.

Evidence: 29/29 green, CI green. Twenty-two mutations, no survivors, including a write escaping, silence instead of 0 W, observers blinded, default-on-for-everyone, the stop claim refiled, and a re-seed moved one line earlier which blinds SAFETY-18. Two mutation findings recorded: one first read as a survivor and was not, because a TypeError killed the section and reported zero reds - FCST-06's shape; and one had to become a PAIR because two fields both hold the detector at 0 W - TEST-16's shape.

Recorded limitation rather than glossed: the re-seed makes the exit safe by construction, and the price is that the loop leg's shadow decision is one slew step rather than a trajectory. Graded by name. The strategies are unaffected, which is why all three motivating defects remain visible.
2026-09-14 17:44:26 +02:00
admin 8f82dd4e06 Merge pull request 'SAFETY-45: size the trade to the headroom instead of interlocking against it' (#88) from SAFETY-45 into release/1.0
With arbitrage armed and a binding peak_cap_w, the loop did not settle: 28 charge onsets an hour, period 131 s, grid swinging -455 to +3200 W, and a billed quarter 59 W OVER the cap it had just spent fifteen minutes holding. Section 10.2 is explicit that an EMS which oscillates is worse than no EMS, for hardware wear and for the peak it is trying to avoid. Not reachable by any unit test in the repo - it needed the closed loop.

THE TICKET'S MECHANISM WAS WRONG AND THE AGENT DISPROVED IT. I wrote that the quarter boundary drives the cycle. Of the 27 gaps between the 28 onsets, 23 are 90-120 s entirely INSIDE one quarter; the four long gaps are exactly the four that SPAN a boundary, so the boundary lengthens the interval rather than causing it. A fix aimed at boundary handling would have removed 4 of 28.

The real cycle is a binary interlock keyed on a continuous quantity: the trade charges at max_w while `wanted = batt_w + excess` is still negative and the guard files nothing; `wanted` crosses zero; the guard engages on a FIVE WATT floor; that flips guard_state(), which cancels the WHOLE trade; the grid-following loop - which targets grid = 0, not grid = ceiling - takes the actuator, discharges to +1870 W and exports 420 W; the projection collapses; the trade re-arms at max_w.

So the fix sizes the buy leg rather than interlocking it. control.maintenance_charge_floor() already caps MAINTENANCE charging at the headroom under the site's cap, because a maintenance charge was the only thing big enough and long enough to set the peak - and that stopped being true when OPT-04 landed. peakguard.charge_headroom_w() publishes the same quantity off the MEASURED guard rather than the optional forecast entity, arbitrage.decide() takes it keyword-only and sizes the buy, main.py passes it. It is wanted_w read in the other direction: no new arithmetic and no new constant.

THE GUARD'S DECISION FUNCTION IS UNTOUCHED, and that is the proof 2026-08-20's bang-bang did not come back. peakguard.py is +139/-0 - zero deleted lines - and sha256(decide) is identical on both trees at 7252 bytes; replay_ac3.py reproduces 190/190 records, 110 engaged, 878 Wh identically. Verified independently before merge. Reverting that rung is red on eight named checks.

Rejected and recorded: a negative `lo`, because it creates a lo > hi contradiction against main.py's cheap-window maintenance shaping that resolves to 0 W - the battery parked in the billed quarter - and closing that would mean suspending maintenance shaping permanently on every affected site. And a backoff timer in arbitrage, because both modules' notes forbid inventing timers; the trade now re-arms at `ceiling - load`, which IS learning from the refusal.

After, on the same rig and the same command: onsets 28 -> 1, grid swing 3655 -> 282 W, and the billed quarters land at exactly 1500.0 W three times over. At the shipped defaults the two affected rows buy ~2% less energy and the worst quarter goes from 59 W over the cap to zero - which is section 10.1's ordering, since the tariff bills the month's single worst quarter. On an aggressive cap the sized trade buys 58% MORE. The non-binding control row is bit-identical.

Evidence: 29/29 green, CI green. Fourteen mutations, all red, two of them zero-byte. The regression closes the loop over the shipped guard, strategy, arbiter, control law and the real QuarterAverager, and asserts BOTH directions from one changed argument plus an inert-where-inert control.

TWO DEFECTS FOUND BY THE DISCIPLINE RATHER THAN BY REVIEW. The agent's own harness restored two edits to one file in list order and left one on disk - caught by the post-revert fingerprint, habit 18 biting a tool written the same afternoon. And test_peakguard.py part 1 formatted floor_w with a bare :.0f one line after the check that reverting the 2026-08-20 rung turns red, so the file ABORTED and parts 2-13 went ungraded: that mutation's coverage was one check and is now eight.
2026-09-14 16:20:39 +02:00