adminandClaude Opus 5 cfafdffaed
checks / unit (pull_request) Successful in 8m0s
PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1
Two files, and no third. config.yaml 0.10.1 -> 0.11.0; CHANGELOG.md gains
`## 0.11.0` and three corrections to sections below it.

A MINOR BUMP, NOT A PATCH. TEL-11 adds an option - `pv_entity`, 75 keys -> 76 in
`options:` and `schema:` together - which is the same test 0.8.0, 0.9.0 and
0.10.0 were cut on. Nothing here can refuse a stored blob: the key is `str?`
with an `options:` default of "", validate.py does not mention it, no default
moved and no enum widened, so a blob that starts the add-on on 0.10.1 starts it
on 0.11.0.

THE TABLE HAS TWO ROWS AND THE WINDOW HAD FOUR MERGES. CI-9's follow-up
(9f6b9f1, `.gitea/workflows/checks.yml` only) and SEC-2 (239e120,
`docs/RELEASE.md` + README.md) are excluded under PKG-15's rule - AUDIENCE, NOT
IMPORTANCE. Neither file is under `goodwe_controller/`, neither is in the built
image, neither is in predeploy_check.py's RUNTIME tuple, and there is no version
of this add-on on which an operator can observe either. SEC-2 is the closer call
and the section argues it in full rather than asserting it: it is the more
consequential ticket of the two - it is why this release is a pull request
rather than a push to master - and it is still a procedure for whoever cuts a
release, not something the person deciding whether to press Update can act on.
Both are named in the section with pointers to PR #102 / checks.yml and PR #108
/ docs/RELEASE.md.

WHAT THE ENTRIES LET AN OPERATOR DECIDE. SAFETY-56: behaviour byte-identical
(6030175ed2ab..., reproduced in the CI image over 2390 capture reads, a 66-cell
grid stepped 120 times and six driven worlds), three surfaces named with the old
and new wording side by side - the STALE_READING line quoted onto the action log
and status page, the SAFETY-37 ERROR log line, and the readiness row that
asserted a false fact about a named entity. TEL-11: unset is byte-identical in
BOTH the control and telemetry documents, set is byte-identical in the control
document only; the three TEL-11 rows of that table were re-measured in the CI
image on this tree (control 846a10a5... twice, telemetry a443a6ce... / 4e6d1cb2...).
It is stated plainly that pv_entity is not a control input and does not change
what the loop does, and that absence publishes `unknown` rather than 0.

THREE CORRECTIONS BELOW THE NEW SECTION, WITHOUT REWRITING HISTORY. The 0.10.1
preamble said SAFETY-56 was open; the SAFETY-57 entry said its accusatory
diagnosis half was "deliberately untouched"; the 0.10.0 preamble left SAFETY-56
with no pointer while SAFETY-57 had one. All three quotations are what the
0.10.1 image actually prints and are left standing - a reader on 0.10.1 has to
recognise them - each now scoped to 0.10.1 and pointed at `## 0.11.0`.

VERIFIED. test_version_gate.py part 11 all four: 11a one contents table and the
slicer closed (302 lines under '0.11.0'), 11b 0.11.0 == config.yaml, 11c all
three RETIRED_PROVIDERS ids named - scoped to a pre-0.10.0 crossing and pointing
at `## 0.10.0`, which is where the evidence is - 11d still exactly one
`## Unreleased` below, PKG-08's, untouched. 31/31 in the CI image, checks.yml's
exact command, purged tree, `:ro`.

Not deployed and not installed. Shipping is a separate pull request from
release/1.0 into master, per docs/RELEASE.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 18:50:13 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide
docs/RELEASE.md            how a change reaches the battery - `master` is
                           protected, releases go via PR from `release/1.0`

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
18 MiB
Languages
Python 98.1%
JavaScript 1.2%
CSS 0.3%
Shell 0.2%
HTML 0.2%