Reviewed on the PR (issuecomments 1480, 1485, 1488, 1489). Documentation only: docs/RELEASE.md (new, 116 lines) plus a 2-line pointer in README.md's file map. No code, no workflow change. Verified against the forge rather than accepted from the document: - Both branch_protections rules re-read field-for-field identical (enable_push false, enable_force_push false, status check `checks / unit (pull_request)`, required_approvals 0, block_admin_merge_override true, no whitelists, no file patterns); master's rule created 2026-09-23T03:09:21; default_branch still master. Section 2's After table is exact. No protection was changed by this review - both rules re-read with their original updated_at. - The empty-PR 405 trap reproduced independently on my own control (throwaway PR #111 between two same-SHA unprotected branches): empty PR -> 405 "Please try again later"; same PR after one commit -> 409 "head out of date". Section 1's "read the message, not the code" is correct and both messages are quoted accurately. PR #111 closed, branches deleted. - release/1.0 (b0b24e5) is an ancestor of master (0f14c2a), so a literal release PR is empty right now - PR #109 has 0 commits, 0 files, and Gitea opened it anyway. Section 1's closing note is right. - A master-base PR gets a genuine CI run, not a laundered skip: PR #107 headcb7e45b3shows Waiting -> In progress -> success, "Successful in 7m56s", run 814. This PR's own head9d593429likewise, run 818. - All five required steps are present and correctly ordered: work merges to release/1.0 with a version bump in goodwe_controller/config.yaml; release via PR release/1.0 -> master; direct push refused; green check before merge; `ha store reload` after, without which the Supervisor keeps serving the cached version. required_approvals: 0 is stated twice, so no reader can believe the dev/review split is enforced. One non-blocking defect left open (issuecomment 1485): section 1 calls0f14c2a"the only commit on master that carries no (#NN) merge suffix". 274 of master's 297 commits carry no suffix. The true statement is stronger - no release has ever reached master through a pull request, and6f5e8e3(0.10.0) was promoted by the same direct push one release earlier, so 0.10.1 was the second, not a one-off. Background, not procedure; wants a follow-up line change. A third comment of mine (issuecomment 1488, merge style) is withdrawn in issuecomment 1489 - it rested on a premise I had not checked and which is false.
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI — routes only, status and configuration
config_page.py the configuration page's markup, style and script
configui.py its field model, built from the Supervisor's own
schema + translations — owns no key, label or rule
selfconfig.py reading and writing this add-on's own options,
with the validate-first / compare-and-swap gate
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
tools/supervisor_selfapi_probe.py what the Supervisor really permits and
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
docs/RELEASE.md how a change reaches the battery - `master` is
protected, releases go via PR from `release/1.0`
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.