master
598
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
d64790b3e2 | Merge pull request 'TEST-15: purge the bytecode cache before a mutation run, not after' (#27) from TEST-15 into release/1.0 | ||
|
|
83911ed637 |
SAFETY-20: measure the freeze rail against the reachable ceiling, not max_w
checks / unit (pull_request) Successful in 3m37s
SAFETY-18's conjunction needs `abs(commanded_w) >= 0.95 * max_w`, but the
emitted command is clipped to the setpoint device's own [dev_min, dev_max]
range as well as to max_w - in clamp_to_rating()'s second stage and again as
the arbiter's `device` P_SAFETY limit claim. Measured on the shipped predicate
at the ticket's numbers, max_w 5000 on a +-4700 W inverter:
looks_frozen(unchanged_s=3600, commanded_w=4700, max_w=5000) -> False
The command is pinned at the hardware's rail, the meter has been frozen for an
hour, and term 2 is unsatisfiable by construction because 4700 < 4750. Any
device rating at or below 0.95 * max_w disarms the conjunction outright, and
the status page then printed `armed (... command is over 4750 W)` - a guard
that cannot fire, advertising that it can, which is the failure SAFETY-15,
SAFETY-19 and validate.py rule 5 all exist to prevent.
The rail is now measured against min(max_w, |dev_min|, |dev_max|), through a
new `rail_ceiling_w()` threaded into looks_frozen(), FreezeWatchdog.evaluate()
and both call sites in main.py. An unread rating leaves the old behaviour
exactly, and correctly: hass.limits() returns None whenever ESPHome is not up,
and on that path no device clamp is applied either, so max_w really is the
ceiling. A rating larger than max_w cannot raise the rail - this is a min(),
not a swap.
THE DELIBERATE CHOICE, since SAFETY-03 has landed. The arithmetic was kept
rather than substituting Decision.i_clamped / Decision.clamped. i_clamped is
the integrator bound (control.py:208, `bounded != i_w`), not "the command is
at the device rating", and `clamped` is the max_w output bound, unreachable on
a default install - neither is the device rail. More decisively, both answer
"did the LOOP ask for more than a bound", while the rail term asks "is the
command standing at the ceiling", and those coincide only when the loop is the
claimer that won. A maintenance SET or a peak-guard floor reaches the ceiling
through arbiter LIMIT claims with no clamp engaging at all, so a boolean rail
would go False exactly during a maintenance phase running against a frozen
meter - which freeze.py's own docstring names as the same fault with a worse
actuator behind it. The predicate is also public with two call sites that pass
DIFFERENT command values (self.target, and `standing` = last_write); a
per-cycle boolean cannot be passed per call site, so substituting it would
have silently decided the pre-clamp-versus-wire question that PM recorded as
still open. AC 1 governs, and it is satisfied literally.
The smaller of the two device bounds, not a per-sign pair. A per-sign rail is
tighter and is not wrong, but it is two rails needing two coverage verdicts on
a status row that carries one number, and the only configuration that
distinguishes them is refused at startup anyway. The symmetric ceiling can only
lower the rail, which widens term 2 rather than disarming it; term 1 carries
the whole no-false-positive argument and is untouched.
A ceiling of 0 W is NOT COVERED, not "armed at 0 W". A device that can command
nothing in one direction would make `abs(command) >= 0` true of every command
including a parked one - term 2 degenerately TRUE, collapsing the conjunction
into the bare unchanged_s > N threshold TEL-05 refused for false-tripping at
this controller's own operating point. rail_unreachable() returns the reason,
looks_frozen() stays silent, and the page uses the NOT COVERED row the
unsupported-transport case already has - a second reason to use that surface,
not a new mechanism.
AC 4, decided rather than assumed: NO NEW validate.py RULE. The configuration
is max_w above the device rating, which rule 2 (CFG-01) already refuses on the
identical predicate, re-run by run_control() once the real rating is known:
validate_startup_config({... max_w: 5000}, -4700, 4700)
-> ['max_w is 5000 W but number.sp accepts at most 4700 W - THE DEVICE
WINS ...']
A rail-specific rule would fire on a strict subset of that (0.95 * max_w >
dev_max implies max_w > dev_max) and could never be the rule that stopped a
start. The residue is the state where hass.limits() answered (None, None) -
ESPHome not up at boot, range checks skipped rather than guessed at, rating
never re-read - and there is nothing to refuse there by construction, which is
why the answer is a runtime row. Recorded in validate.py's "deliberately not
refused" list and pinned by four checks in test_validate.py, so the decision's
premise goes red if rule 2 is ever softened back to a warning.
HOW REACHABLE THIS IS, stated rather than glossed. Because rule 2 refuses the
configuration whenever the rating is known, min(max_w, dev_max) IS max_w on
every install that reaches the control loop with a rating it could read, and
this change is arithmetically dead there. That is clamp.py's argument for its
own second stage word for word: the case where it bites is the case where the
startup gate did not run or no longer holds, and a guard that quietly assumes
the gate ran is a guard that reports armed in exactly the state it cannot fire
in.
Verified by breaking it, per this project's rule. Reverting rail_w() to bare
max_w fails nine checks; deleting the NOT COVERED handling fails five. The one
that mattered: shipping the corrected predicate while NOT passing the rating
from check_meter_frozen() left the entire suite green, because nothing graded
the caller - so test_freeze.py part 5b now drives the real cycle() on a +-4700 W
device and asserts on the notification that leaves the process, and the
unwiring mutation fails three checks there. The peak-guard call site's wiring
is still ungraded (behind p1_enabled, needs a fed averager for `frozen` to have
any observable consequence) and that gap is named in the file rather than
implied.
Full suite: 15/15 in goodwe-addon-ci.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
|
||
|
|
7b4877d56d |
TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran, and reported the mutation as a survivor. It was not one. CPython validates a cached `.pyc` on (source size, source mtime truncated to whole seconds), and that edit moved neither number - same length, same second - so the interpreter loaded the bytecode it already had. Disassembly settled it at the time: the source read `here`, the running code loaded `self`. A mutation run had graded code that was not there, with no error and exit status 0. This does not make the results already on the record wrong. It makes them UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a campaign and nothing here quietly assumes the old numbers hold. REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two return values are the same length, imports it in a real subprocess, rewrites it inside the same second (retrying until both writes land in one whole second - milliseconds, no sleep) and reads back which value ran. Part 1 shows the interpreter running SELF off a file that says HERE. AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only. Neither stops an EXISTING stale .pyc being read, and a mutation run always has one, because the previous run wrote it. Part 2 grades both still running the old code. The advice in test_control.py's coverage audit led with `-B`; it is corrected here - the purge is the half that works, and `-B` earns its place by keeping THIS run from leaving a cache for the NEXT edit to inherit. NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy. Waiting it out would slow every run down and would still only cover the edit somebody remembered to slow down. THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of every app/*.py it is about to grade - so a mutation report can say WHICH source produced it, which is the reviewer's addition to this card - runs each suite under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's reason), and fails if a cache appears during the run. It takes the tree as an argument so the infra repo's replay harnesses can call it without being moved. WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement, the reporting rules and the survey, and every one of the 16 suites now points at it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py part 5, so a new suite that joins this directory without the pointer is red - the same failure shape CI-01's file glob exists to prevent. CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit status 0 - while the same probe on a writable mount produces one. Each job also rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the `:ro` is one character wide and the next person debugging a write will be tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the file - the first draft searched the whole workflow and stayed green after the flag was deleted, because the comment explaining it still named it. THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed: goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was written. There is no deploy-side finding. THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is one-directional - a mutation that never took leaves the suite green, so stale bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every "all red, no survivors" claim in the window out of scope, along with mutations executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where no source file is edited) and everything run after the purge discipline landed on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is the recorded SURVIVORS from source-edit runs before that date. Two were re-run here under the harness and both still stand: TARIFF-01's record_block() ignoring its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green each, on the tree as it stood. The rest are labelled still-unverified rather than assumed or re-run; each is one harness run to close, and the moment to spend it is when somebody next touches that module. OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today), so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes a tree argument for exactly that, but the change belongs in that repo and some of those harnesses want the rig. RED AND GREEN. Every new check was broken and watched fail: the purge commented out of the harness turns part 4 red (and its non-vacuity probe already proves the fixture would mis-grade without it); one docstring pointer removed turns part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow turn part 6 red. Full suite green, 16 files, in the CI image on a read-only mount - the shape the runner uses. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> |
||
|
|
358fbb0172 | Merge pull request 'TEST-17: grade the status page's peak row at a stated month, not at today's' (#26) from TEST-17 into release/1.0 | ||
|
|
504e8daac3 |
TEST-17: grade the status page's peak row at a stated month, not at today's
checks / unit (pull_request) Successful in 3m35s
release/1.0 went red at 00:00 on 2026-09-01 on a commit nobody had touched. `Controller.checks()` read the capacity-tariff peak with `self.peak.peak()` - no argument - so tariff.py resolved the month from `datetime.now()`, while test_tariff.py section 10 banks its quarter at the fixed fixture 2026-08-30. From 1 September the page was correctly asked for September, correctly answered NO_RECORD, and the row read "no completed quarter recorded yet" - a string containing no "peak", which the section's own filter required. Four checks failed. ISOLATED BY MOVING ONLY THE CLOCK. Same commit, same shipped-deps image, libfaketime: green at 2026-08-30, four failures at 2026-09-01. Identical at |
||
|
|
f6ecd5ff03 |
DATA-01: thirty days of the real meter, and what AC 3 actually measures (#25)
Thirty days of the house's own P1 meter, exported from HA's recorder with a committed exporter, closing the dataset gap that made TARIFF-01's and SAFETY-07's AC 3 unmeetable. 2879 closed quarters, 485841 samples, 99.950 % covered, 13 gaps over 30 s and nothing interpolated. Reviewed independently. The re-export is byte-for-byte identical after decompression on both previously committed days (865024 B / 15600 samples and 894387 B / 16351 samples), verified by decompressing and comparing rather than by reading --verify; the only difference is the gzip mtime field, and writing 0 rather than a wall clock makes this exporter reproducible where the 2026-08-25 one-off was not. The committed CRLF is reproduced rather than tidied because reproducing it IS the verification, and .gitattributes marks *.gz binary so git can never drift it - confirmed with git check-attr. All 30 manifest sha256s match. replay_ac3.py --expect 189/190 reproduces test_peakguard part 6 exactly: 5029.8 -> 3485.3 W, 189/190, 878 Wh, 110 graded + 5 blind - every one a figure the reviewer had already derived independently on a different harness while reviewing TARIFF-01 and SAFETY-07. AND THE RESULT IS A FINDING ABOUT THE CRITERION. Over the month the guard takes the peak from 5029.8 W to 4107.3 W (-18.3 %, still over the 3500 W soft limit) while moving the interval count from 98.89 % to 98.99 %. The UNCONTROLLED month already passes the 95 % bar, with 112 quarters of slack, and the guard contributes 3 - a signal-to-threshold ratio of 0.021. The criterion counts intervals while the capacity tariff bills the month's maximum, so it cannot separate a working guard from an absent one. AC 3 is met on the letter and uninformative on the substance; it should not be read as evidence the guard works, and if rewritten it should be on the monthly peak. The failed-read discipline was verified by producing all three states: a typo'd entity and an unreachable recorder both exit 1 having written nothing, and a day whose read fails is recorded FAILED with file null, no .gz, days_failed 2 and empty_days [] - so an empty response cannot look like a quiet hour. The 30 days sit in a subdirectory and are glob-invisible to both suites' non-recursive scenarios/p1-net-*.jsonl.gz; neither suite had a check added, removed or altered. Full suite green, 15 files. |
||
|
|
04292c4a08 |
DATA-01: thirty days of the real meter, and what AC 3 actually measures
checks / unit (pull_request) Successful in 3m36s
TARIFF-01 and SAFETY-07 both merged with AC 3 - "monthly peak held under
the soft limit in >= 95 % of intervals over a 30-day simulation replay" -
honestly unmet, because two days of capture existed and it was believed
nothing longer could be produced. That belief was a true statement about
the past read as a claim about the future: HA's recorder still held the
whole month, and the reason nobody found out is that the 2026-08-25
export was a one-off script that left no artefact.
So the exporter is committed and runnable now.
scenarios/p1-net-30d-2026-08/ is 2026-08-01 to 2026-08-30, 485,841
samples, 30/30 days read, 0 failed, 4.13 MB gzipped, in the schema the
two committed days already fixed.
VERIFIED AGAINST THE DAYS THAT EXIST. `--verify` re-fetches 2026-08-20
and 2026-08-23 by this exact route and reproduces both committed files
BYTE FOR BYTE after decompression (865,024 B / 15,600 samples and
894,387 B / 16,351 samples). The gzip containers differ by design: this
exporter writes mtime 0 so its output is reproducible, where the one-off
wrote a wall clock.
A FAILED READ IS NOT AN OBSERVATION. A day whose read fails writes no
file, is recorded "read": "FAILED", and the run exits non-zero; the
entity is proved to exist through /api/states before any empty day is
believed, because a typo would otherwise answer 200 [] thirty times and
produce a consistent dataset of nothing. Nothing is interpolated, so the
month's 13 gaps (1291 s, 99.95 % covered) and its 3 `unavailable`
samples stay visible as holes.
SIZE: COMMITTED, DELIBERATELY, AND MEASURED. A git bundle of the whole
history goes from 1.58 MB (release/1.0 @
|
||
|
|
86c43eba24 |
DATA-02: twelve months of real Belgian day-ahead prices, closing OPT-04 AC4 (#24)
8760 hourly EPEX BE clearings from the Energy-Charts API (Fraunhofer ISE), CC BY 4.0 from Bundesnetzagentur | SMARD.de, committed with attribution and a fetcher that refuses to write if the licence stops saying CC BY 4.0. Raw wholesale with all_in false and the markup/levy/VAT assumption labelled as an assumption; the additive terms cancel out of every daily spread, so trade counts turn on the VAT multiplier alone. DST handled by iterating in UTC and rendering through price.brussels(): 25 points on 2025-10-26, 23 on 2026-03-29. app/ diff is zero lines - nothing tuned. Section 7B asserts that the real year cannot grade section 17, so the synthetic year stays. |
||
|
|
d57122ec74 |
DATA-02: a real Belgian price year, so AC4 stops being unmeetable
checks / unit (pull_request) Successful in 3m36s
OPT-04 reported AC4 - "net-positive across 12 months of replayed prices" - as NOT MET and replayed a synthetic year, because scenarios/ held only P1 meter captures. Right call, wrong diagnosis: the criterion was being carried beside a 30-day METER criterion as though both needed waiting. EPEX BE day-ahead is public data, not a capture. It needed a fetch. 8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, canonical three fields. Licence checked BEFORE committing: Energy-Charts publishes the BE zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under private-use-only terms, so this one is redistributable with attribution. The fetcher refuses to write a file whose per-response license_info stops saying so. Cross-checked against SMARD's own 4996/DE: 96 of 96 quarter-hours, max difference 0.00 EUR/MWh. Raw wholesale, and the file says so. all_in: false, with the markup/tax assumption carried as numbers to APPLY rather than numbers applied - TARIFF-02's trap in data form. Section 7B applies it in one visible place and asserts arithmetically that its additive terms cancel out of every daily spread, so the trade count turns on the VAT multiplier alone; the raw replay is run too, so how much rests on the guess is reported (110 vs 88). DST by construction: iterate in UTC, render through price.brussels(). 2025-10-26 is 25 points, 2026-03-29 is 23, verified by counting per Brussels day rather than asserting 24, and by checking October's 02:00 appears twice at two offsets with two prices while March's never appears. Both bugs the point-and-gap accounting caught were real: a UTC-bounded window made the first day 22 hours, and an inclusive-end off-by-one dropped the last day silently. A day nobody asked for is not a day with no prices. THE RESULT, AT THE SHIPPED DEFAULT, WHATEVER IT IS. At 0.10 widened 1.5x to 0.1500: 110 round trips, +24.88 EUR net of the cycle cost. Unwidened, 173. Nothing tuned - the threshold and the 2.5/1.5 factors are untouched. And what the owner's decision now has under it: the four reports that a static ~0.0840 spread does not clear 0.10 all STAND. What was missing is that a dynamic site clears the widened requirement on 121 of 365 days, median all-in spread 0.1130, so a median day would clear at 0.0754 - 156 trips, +35.42 EUR. Reported, not applied. The synthetic year stays, because the real one cannot grade section 17: not one of 365 days has a negative DEAREST hour, so a zero there counts something that could not happen. 7B asserts that degeneracy rather than reporting the zero. Size measured, not assumed: 893 KB plain but 74.6 KB as a git object against 56.5 KB gzipped. Git already compresses; 18 KB is not worth making the provenance block - the licence claim a reviewer must check - unreadable in a diff. Nothing wired into the add-on; generic_dayahead is still the live path. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
4601682815 |
SAFETY-24: an energy floor under the peak guard's forced discharge (#21)
SAFETY-07 could command a discharge to hold a billed quarter down and nothing below it consulted the state of charge - the BMS was the sole energy backstop. decide() now takes soc and soc_floor, and discharge_permitted() is the one place the question is answered: public, no default arguments, and consulted only AFTER a forced discharge is actually being asked for. The denied action is a 0 W floor - one-directional, forbids charging, structurally cannot cap the discharge the loop is already doing. Reviewed independently. The trade-off is ruled honest and was made a check rather than a footnote: on a pack deliberately sized so the floor must bind, the worst quarter goes 4338 -> 5030 W while end SoC goes 9.6 -> 20.0 % and cycles pinned at the BMS cut-out go 1227 -> 0. Reproduced on the reviewer's own replay, including the 304.2 Wh withheld against 292.8 Wh between the two floors - half a cycle at the rail apart, so the floor is doing the arithmetic it claims. The guard's central guarantee was re-derived across 19,800 combinations of load x elapsed x battery x SoC x floor: 0 negative floors, 0 claims with hi other than +inf, 0 decisions both floor-limited and saturated, 0 arbiter resolutions lowered or contradicted. Rule 8's <= is right: at equality the EMS floor could never be the thing that stops the discharge. Eleven author mutations plus nine reviewer ones, all red under python -B with a purged __pycache__ and real byte deltas. One survivor is an equivalent mutant and provably so: a float(soc or 100) defaulting above the call site is dead code, because a Controller with no SoC never reaches decide() at all - inputs_ok is False and cycle() stops at the safety claim first. That property is now asserted on the service call, replacing an assertion whose sentence was wider than its check. Merged after two rebases. The second one broke a grader neither card could have seen alone: test_peakguard graded the FIRST .decide( in main.py and required exactly one, which stopped being true when OPT-04 added arbitrage.decide(). It failed loudly rather than grading the wrong call. Fixed by selecting peakguard.decide by qualified name and requiring exactly one of that, verified still red on a decoy and on the maintenance_soc_floor swap. Follow-ups filed as SAFETY-27, not addressed here: arbitrage_soc_floor has no rule-8 twin against bms_soc_floor, and this card's own 'revisit if a third floor appears' trigger has fired. |
||
|
|
9234016419 |
Merge release/1.0 (OPT-04) into SAFETY-24, and fix one grader the merge broke
checks / unit (pull_request) Successful in 3m36s
OPT-04 landed after the previous rebase. Conflicts were CHANGELOG.md and one IMPORT LINE in validate.py; both refusal blocks and both option sets survive untouched, and DOCS.md, main.py and config.yaml auto-merged. ⚠️ AND THE MERGE BROKE A CHECK THAT NEITHER CARD COULD HAVE SEEN ALONE. test_peakguard.py graded "the first `.decide(` call in main.py" and asserted there was exactly one. That was true when SAFETY-24 was written; OPT-04 added `arbitrage.decide(...)`, so the merged tree had two and the assertion failed. It failed loudly rather than grading the wrong call - the guard did its job - but it cannot ship red. Fixed by selecting the call by QUALIFIED NAME (`peakguard.decide`) instead of by position, and requiring exactly one of THAT. Other modules may now call their own decide(); this grader can no longer be moved by one of them. Verified still discriminating: a decoy `peakguard.decide` added to main.py turns it red on 7 assertions, and the `maintenance_soc_floor` swap still turns it red on 6. Also folded in the review's wording finding. An assertion read "a CONTROLLER whose SoC entity does not answer hands decide() None" while driving no Controller. The wiring property is stronger than the one claimed, and is now asserted on the SERVICE CALL: a Controller with no SoC never reaches the guard at all, because `inputs_ok` is False and cycle() stops at the safety claim first - so a `float(soc or 100)` defaulting line above the call site cannot disarm the floor. The original decide()-level check is kept, reworded to say what it actually grades. Full suite green on the merged tree: 15 files. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
b7272169b1 |
SAFETY-26: pin the negative-price boundary from below, not just from above (#23)
Closes the survivor found reviewing OPT-04: price < 0 weakened to < -0.001 left every suite green while a -0.0005 EUR/kWh sell hour discharged. Pinned as a sweep rather than a point - five magnitudes spanning >10000x down to -0.000001, the last place the canonical 6-decimal format expresses - with the well-formedness of each stimulus asserted first so section 17 is the only rung that can refuse, and the same five sign-flipped asserted to discharge so it is a boundary at exactly zero. app/ untouched. |
||
|
|
2b8b8cb97f |
SAFETY-26: pin the negative-price refusal from below, not only from above
checks / unit (pull_request) Successful in 3m15s
OPT-04's reviewer weakened `if price < 0` to `if price < -0.001` and every suite stayed green while a -0.0005 EUR/kWh sell hour discharged. The shipped code was right the whole time; the CHECK could not tell correct from nearly-correct. The only probe near the boundary sat at 0.0000, which catches a `<=` and says nothing about a tolerance invented on the other side - and a tolerance on the other side is §17's named regression walking through with the suite passing. A dearest hour at -0.0005 is an ordinary Belgian day-ahead print, not a fuzz value. `app/` IS NOT TOUCHED. `if price < 0` is already correct and changing it would be the defect; this card closes the check, not the behaviour. The 0.0000 probe stays and is now labelled as the half that pins the boundary from above. The new probe is a SWEEP rather than a point, because one probe at -0.0005 closes `-0.001` and nothing else - a mutation reaching for `-0.01` would be the identical defect one decimal further out. Five prices span four orders of magnitude down to -0.000001, the last place the canonical six-decimal format can express; each is asserted to survive that rounding as strictly negative, to still be the DEAREST hour, and to still clear the widened threshold, so §17 is the only rung that can refuse. The same five magnitudes with the sign flipped all discharge, so this is a boundary at exactly zero rather than a refusal of small numbers. AC4, the look: every price/quantity boundary in arbitrage.py and static_tariff.py was given the same tolerance mutation, both directions where both exist. Two survive, both in static_tariff.py and both NAMED RATHER THAN FIXED - they are TARIFF-03's rungs and want probes in its own file. `spread == 0.0` loosened to `<= 0.001` flips a real 0.0005 spread from allowed to refused at min_spread_eur_kwh=0.0, a documented supported value, and otherwise prints a false reason about a tariff that is not flat. `len(firm) < 2` loosened to `< 1` survives at +0 bytes - TEST-15's risky delta - and is masked only by the flat rung, so the two mask each other and a later edit to either opens a hole nothing reports. Mutation verified under `python -B` with a recursive __pycache__ purge, byte delta printed (+5 B), the mutated line asserted changed, and - per the reviewer's addition to TEST-15 - the tree re-read from disk and asserted to be the tree that was mutated before each run. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
8e589fee3f |
OPT-04: price arbitrage, at priority 3, shipped switched off (#22)
app/arbitrage.py consumes TARIFF-02s canonical prices, TARIFF-03s Arbitrage verdict and FCST-03s firm/provisional split rather than re-implementing them. An idle decision files NO claim - a 0 W set at P_ARBITRAGE would out-rank the loop and kill self-consumption. Peak shaving is honoured twice: TARIFF-03s required peak_guard_active interlock, and P_PEAK 50 clamping P_ARBITRAGE 30 in the arbiter. The fetch lives in run_tariff_refresh(), asserted on the shipped AST to be absent from cycle() and read_inputs(). Selling into a negative-price hour is refused. arbitrage_enabled ships false. |
||
|
|
bdd7f18a54 |
OPT-04: charge cheap, discharge expensive - and only when it pays
checks / unit (pull_request) Successful in 3m16s
Four cards built the price stack and nothing traded on it. app/arbitrage.py is §10.1's priority 3, and it consumes all four rather than re-deciding anything: whether a trade is permitted at all, on which two hours, against which widened threshold is TariffPlan.arbitrage()'s answer, and that answer cannot be obtained without first saying whether the peak guard is holding. §9.1's "peak shaving outranks arbitrage" is therefore honoured structurally - there is no path to a spread that skips the question - and again in the arbiter, where P_PEAK (50) clamps a claim filed at P_ARBITRAGE (30). A guard that never ran is not a guard that is clear. On meter_source off the peak guard is never evaluated; that third state is carried as None and refuses, because charging at the rail creates the billed quantity while nothing measures the quarter. validate.py refuses that configuration too, along with arbitrage armed with no price source and a SoC floor at or above the ceiling. §17: never export into a negative price. The guard is on the hour being sold into, not on the spread - a day priced -0.30 .. -0.05 clears any threshold and its dearest hour is still negative. Buying in a negative hour stays allowed. resolve_tariff() may open an HTTPS connection and the tick feeds the ESP32 heartbeat, so the fetch runs in its own task at a 30 min cadence and the tick reads an attribute and an age bound. test_arbitrage.py section 8 asserts that structurally on the shipped AST: a fetch put back on cycle() is red. AC4 is NOT met and is not restated - this repository holds no price history. Section 7 replays a synthetic year and asserts the property that does not need real prices: every executed round trip cleared its own widened requirement, and zero discharges landed in the 522 negative-priced hours. At the shipped 0.10 EUR/kWh threshold a realistic Belgian day/night site does not trade at all. Reported, not tuned: that number and FCST-03's widening factors are one product decision and it is the owner's. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
a1376e44e4 |
Merge release/1.0 (FCST-03) into SAFETY-24 - CHANGELOG only
checks / unit (pull_request) Successful in 3m28s
FCST-03 landed while this was in review, so both branches had prepended an Unreleased stanza. Only CHANGELOG.md conflicted, exactly as predicted; app/, config.yaml, validate.py and DOCS.md all auto-merged, and this card touches neither price_forecast.py nor static_tariff.py. Both stanzas kept verbatim, SAFETY-24's above FCST-03's - no text from either author edited. Full suite green on the merged tree: 14 files. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e709554857 |
SAFETY-24: an energy floor under the peak guard's forced discharge
checks / unit (pull_request) Successful in 3m29s
SAFETY-07 can command a discharge to hold a billed quarter down, and nothing below it consulted the state of charge. On the 2026-08-20 replay it asks for 878 Wh in a day. Relying on the BMS is not absurd - it is a real floor and it works - but it is the pack's protection rather than the operator's, and a month of aggressive quarters leaves the battery repeatedly at that cut-out with no EMS-side record of why. The first symptom is a pack never available when wanted, which is indistinguishable from the SoC drift MAINT-01 exists to correct. decide() now takes soc and soc_floor, both required and neither defaulted, and discharge_permitted() is the one place the question is answered. Above the floor nothing changes. At or below it the guard files a 0 W floor instead of a sized one - one-directional, so charging stays blocked and no discharge is capped - and reports floor_limited with the reason it bound. It is not a trip: every stop in 11.2's table still outranks the claim, and the floor is never negative, so 9.1's asymmetry survives as a property of the object (0 negative floors over 1296 swept combinations, SoC included). The SoC is graded only after `wanted > 0` is established, so it is never evaluated where it governs nothing. An unreadable SoC is floor-limited, not a full battery - a full battery is exactly the value that would disarm the floor, and this project shipped that defaulting once already. Failing to shave is not silent: one notification per episode (goodwe_peak_soc_floor), distinct from the saturation alarm because the two ask for opposite operator actions, plus its own status row and an action-log line. Verified by replay. The 2026-08-20 capture is driven against a modelled pack sized from the day's own measured appetite, so it genuinely exhausts: without the floor it reaches the BMS cut-out and holds there for 1227 guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The energy withheld equals the energy between the two floors to within one cycle at the rail. The honest half is reported too - the worst quarter goes 4338 W -> 5030 W, because a floor-limited guard shaves less on purpose. Two new options, mirrored once in peakguard.PEAK_OPTION_DEFAULTS (TARIFF-02's pattern), imported by validate.py and main.py rather than typed as literals and pinned to config.yaml by a check that reads the file - so CFG-03 still tracks three places. validate.py rule 8 refuses peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner. maintenance_soc_floor is deliberately not reused and not renamed: it is a drain target, not a spend limit, and the rename is recorded as a decision to revisit if a third floor appears. Eleven mutations of the shipped source were run against the checks; all eleven go red and there are no survivors. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
a30bde1ab1 |
FCST-03: provisional prices - yesterday flagged as yesterday, and unable to move anything (#20)
app/price_forecast.py fills unknown hours from yesterday, flagged provisional by four independent mechanisms: _carried() has no provisional parameter, published points pass through by identity, _audit() re-derives every flag and raises rather than repairs, and an AST check refuses a non-literal provisional. Gate blocks irreversible actions on provisional hours. Arbitrage refusal 3 rewritten to fewer-than-two-FIRM-hours so filling does not switch arbitrage off every morning, with the 11.4 fallback still refused by a truer route. Real-time products get a measured 2.5x wider threshold, following the declared PriceProduct. |
||
|
|
71cd7849e4 |
Merge release/1.0 (SAFETY-07) into FCST-03, and close two degenerate stimuli
checks / unit (pull_request) Successful in 3m13s
CHANGELOG.md was the entire collision - SAFETY-07 lands in peakguard.py, main.py and the arbiter, none of which this branch touches. Both entries kept. X1. `_firm_or_die` guarding only `cheapest` survived, because the check passed the SAME provisional point as both cheapest and dearest: a guard on either role alone raises, so the stimulus could not tell "the buy hour is guarded" from "both are". Now one call per role with a firm point in the other seat, plus the positive arm so the two refusals are discriminating. X6. `firm_points()` returning the carried hours too survived, because its two consumers - the §11.4 refusal and cheap_now - guard provenance independently and both keep answering correctly. The accessor is now graded directly: exactly the published points, by identity and in order. Both are the degeneracy rule this file states at the top, in a new dress - a stimulus that cannot distinguish the two things it grades. ⚠️ AND THE REASON THE M9 MUTATION "SURVIVED" IN MY EARLIER REPORT: a stale __pycache__. Reverting `self.provisional` to `here.provisional` changes neither the file size nor, at one-second resolution, the mtime, so CPython kept the MUTATED bytecode and a green run afterwards proved nothing about that line. Every mutation here now clears __pycache__ first; re-run that way, M9 is caught. The committed source was always correct - the checks were not being run against it. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e7c95bfd8a |
SAFETY-07: cap the loop before it sets the month's billed capacity peak (#18)
The first thing in this system that can STOP a runaway rather than alarm on one. Each cycle it projects the open 900 s block from P1 telegrams and, over the ceiling, files one arbiter claim: a lower bound at P_PEAK, sized as excess = 900*(projected-ceiling)/remaining added to the MEASURED battery power. No writes, no I/O, no clock, no state between calls. Replayed independently by the reviewer on a separate harness: 2026-08-20's billed quarter 5029.8 W -> 3485.3 W, both days 189/190 -> 190/190 under the 3500 W soft limit, 878 Wh modelled discharge on the failure day and 0 Wh with 0 engagements on the healthy one. Verified as properties rather than witnesses: the lo-limit claim cannot cap discharge or export (hi is inf; 0 of 54 loop/floor pairs lowered the target; no floor in 0..5000 W reduces a full-rate discharge; decide() emitted 0 negative floors over 630 input combinations), and the 900/remaining gain is exactly 1.0 at the top of the block, growing, bounded at the end by the achievable_w clamp so it can never file lo > hi. Round one held this PR on three wiring mutations that left all twelve suites green while a default install parked at 0 W in the billed quarter - including the suppression re-gated on the optional peak_forecast_entity, verbatim the historical defect this card's own comment described. All three are closed. The conjunction moved out of main.py into peakguard.shaping_suspended() so the check can assert on the shipped expression, and part 7 now executes the mutations against the real Controller.cycle(). The reviewer confirmed the harness cannot go vacuous: re-inlining the conjunction in main.py with behaviour-identical code turns B1 and B2 RED rather than green, because they assert the mutation takes effect. Eight further reviewer mutations this round, all red, no survivors. One note recorded, not blocking: the parsed-syntax grade on decide(batt_w=...) is defeated by a decoy .decide() call or by overwriting self.batt before the call, and it is the behavioural checks beside it that catch both. AC 3 remains TARIFF-01's and is NOT met - do not close the card as AC 3 met. SAFETY-24, the missing SoC backstop on the forced discharge, is named in peakguard.py with the 878 Wh figure and must land before this reaches a client install. |
||
|
|
dd40c56ab4 |
FCST-03: yesterday's prices, flagged as yesterday's, and unable to move anything
checks / unit (pull_request) Successful in 2m43s
§8.3 fills the hours a day-ahead feed has not published yet with yesterday's profile and flags them provisional, and forbids any irreversible action on such a price. The whole risk of this ticket is one line - a carried point and a published point are three fields and a bool, so `provisional=y.provisional` copies yesterday's False onto today's guess and produces stale data presented as current. That is SAFETY-18's frozen-but-fresh meter one layer up. So the flag is never passed through. Carried points come from a constructor with no provisional parameter; published points pass through BY IDENTITY, so no copy exists that could lose one; an audit re-derives the expected flag for every emitted point and raises rather than repairing; and the check walks the module's own AST so the pass-through idiom cannot come back looking ordinary. A published point may itself be provisional (eneco_eddy's imbalance print is), so the rule for a published hour is "whatever the feed said", never False. The fill keys on the Brussels wall clock rather than t-24h, so the 23- and 25-hour days are right; a late publication rebuilds the series, moving the number and the flag together. AC2 and AC3 landed on TARIFF-03's existing verdict surface rather than beside it. Refusal 3 became "fewer than two FIRM hours" - refusing on "any point is provisional" would have switched arbitrage off every morning on every dynamic site - and refusal 5 is new: the spread must clear a threshold widened by the widest active uncertainty source (max, never a product). The permitting variant now refuses to be constructed around a provisional point at all, and the cheap-window flag became per-hour for the same reason. The irreversible action is a value carrying the hours it commits, derived from maintenance.py's own DRAIN_TIMEOUT_MIN; the gate blocks a maintenance drain whose window reaches into a carried hour, and the phase machine stays idle. It is the price-justified entry point only - a gate that blocked on no_data would stop the monthly cycle on every default install. Zero new config options; TEST-14's signature scan ported to cover both Gate's and Arbitrage's constructors, closing _Refused.reason's open hole. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c2ed509565 |
Merge release/1.0 (TARIFF-03) into SAFETY-07
checks / unit (pull_request) Successful in 3m12s
The anticipated conflict again, and only it: both cards prepend to CHANGELOG.md's Unreleased section. Both entries kept, SAFETY-07 first. app/main.py and DOCS.md auto-merged, so the overlap claim on #18 still holds - config.yaml and validate.py remain untouched by this card even after TARIFF-02 and TARIFF-03 widened both. Full suite green on the merge result, test_price.py and test_static_tariff.py included. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2d570d84ce |
SAFETY-07 review: defend the three wiring mutations that survived
The reviewer's finding was correct and the shape of it matters: everything the
first cut graded was in peakguard.py, and grading the module is not the same as
grading the guard. Three one-line changes to main.py's CALL SITE left all twelve
suites green while a default install parked at 0 W in the quarter that sets the
month's bill.
B2 was the serious one. My own comment described that defect - "that entity is
optional and empty on a default install, so until now the suspension could not
fire on the site that needed it" - and nothing could regress it. A comment that
documents a fix nobody can test is the same shape as a corrected comment nobody
tests, which this project has already been caught by once.
WHAT CHANGED
The suppression conjunction moved out of main.py and into
peakguard.shaping_suspended(), for the reason watchdog.loop_is_following() and
freeze.looks_frozen() live where they do: the check that grades a safety
predicate must assert on THE SHIPPED EXPRESSION, not on a transcription that can
drift apart from it in silence. Its docstring carries both terms and why neither
is sufficient alone. main.py's call site now says READ THAT FUNCTION FIRST, and
records that a reviewer mutated it back to its historical broken form with every
suite staying green.
test_peakguard.py part 7 gains a section that EXECUTES the three mutations
rather than describing them. Each one is put in place on the shipped module and
the REAL Controller.cycle() is driven with it, on the dangerous fixture: a
default install (no peak_forecast_entity, so peak_fc is None and peak_at_risk is
False forever) with maintenance in its CHARGE phase, so a P_MAINT_SHAPE `hi <= 0`
limit is live, and the guard genuinely engaged on the measurement. That the
mutations are monkeypatched onto the shipped module is itself load-bearing: if
main.py inlined either expression again the patch would do nothing and these
checks would pass vacuously.
SHIPPED suspended=True loop -> 1498 W, limited by peak +1497.8 W
B1 suspended=False CONTRADICTION between limits 0.0 W
B2 suspended=False CONTRADICTION between limits 0.0 W
B2b (forecast term dropped instead) - caught by its own check
B3 is graded three ways, because the single-cycle form is only INFLATED and the
failure is what happens on the next cycle:
* the value main.py actually hands decide() is recorded off the real call, with
the measured battery at 0 W and the command standing at +3000 W;
* the one-cycle difference is asserted to be exactly the standing command - the
whole defect in one line, watts that were asked for and never arrived counted
as if they had;
* both forms are then run forward against the REAL controller's own projection
with an inverter that never follows:
intent-sized floor 4482 5000 5000 5000 ... SATURATED at cycle 2
delivered-power floor 1482 1482 1482 1482 ... stationary
* and the call site is graded on parsed syntax, so a rename cannot quietly
reintroduce it: `decide(batt_w=...)` must unparse to `self.batt`.
SAFETY-24 is now named in peakguard.py, in its own section, with the number that
makes it real - 878 Wh of forced discharge on the 2026-08-20 replay - and the
statement that this must not go to a client install before that ticket lands. A
ticket nobody can find from the code is a ticket nobody reads before shipping.
RED AND GREEN
Fifteen mutations run against the shipped modules, each reverted after: the six
new wiring ones (B1, B2, B2b, B3, B3b, and deleting the SAFETY-24 pointer) and
the eight from the first round, re-run to confirm they still bite. All fifteen
turn test_peakguard.py red. Full suite green, test_price.py and TARIFF-03's
included.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
cf5094c608 |
TARIFF-03: the static day/night profile as a first-class product and the 11.4 fallback (#19)
app/static_tariff.py: StaticProfile derives STATIC vs FIXED from its own prices, one generator serves both the configured product and the degradation fallback differing only in the provisional flag. TariffPlan.arbitrage() is a refusal type behind a required keyword-only peak_guard_active, and a flat tariff is refused by arithmetic rather than by matching PriceProduct.FIXED. main.py touched only in read_inputs() else-branch, one field, one status row - nothing in cycle(), the arbiter or the peak path; an empty profile is bit-for-bit the old behaviour. Rule 7 tripwire re-aimed rather than silenced. |
||
|
|
9f8b721a4d |
Merge release/1.0 (TARIFF-02) into SAFETY-07
checks / unit (pull_request) Successful in 3m9s
Conflict was the one anticipated: both cards prepend to CHANGELOG.md's Unreleased section. Both entries kept, SAFETY-07 first. Nothing else of TARIFF-02's surface (app/price.py, validate.py rule 7, config.yaml, DOCS.md) overlaps this card - config.yaml and validate.py are untouched here, so the CFG-03 check still reads a config.yaml that only TARIFF-02 has widened. Full suite green on the merge result, test_price.py included. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
303525cfc5 |
TARIFF-03: static day/night and fully-fixed tariffs, first-class
checks / unit (pull_request) Successful in 2m43s
§9.2 puts a large share of the Belgian installed base on a static profile, and
an EMS that only works under dynamic pricing is an EMS for a minority. A new
`static_profile` option describes a two-period day/night tariff - or a single
fixed price - and app/static_tariff.py turns it into the same canonical
{start, eur_per_kwh, provisional} series the fetched providers emit.
Not a sixth provider plugin, for two mechanical reasons. capabilities() is a
classmethod, so a plugin's PriceProduct is fixed when the class is written -
but §9.2 makes STATIC and FIXED two different products and which one a site is
on is a property of the operator's data; StaticProfile.product derives it from
the number of distinct prices. And the plugin framework exists to stop a
FETCHED figure being marked up twice, which a number typed as all-in cannot be.
So the profile sits where §11.4 already says it does - under the providers, as
the fallback. Configured product and feed-is-down are one generator differing
in one flag, so the degradation path cannot rot unused.
"No arbitrage" is a type. TariffPlan.arbitrage() returns a variant whose
ALLOWED arm carries the spread and the cheapest/dearest hours and whose REFUSED
arm carries a reason and nothing else - .spread_eur_kwh on a refusal raises
rather than answering 0.0, so an optimiser cannot compute a trade from one.
Four refusals, all derived: peak guard holding, no price data, plan
provisional, or the series is FLAT. The last is AC2: a fixed tariff disables
arbitrage by arithmetic, not by matching on an enum. peak_guard_active is a
required keyword argument, so §10.1's priority 2 over 3 cannot be skipped.
Time-window shifting reaches the one shiftable load that exists: main.py's
cheap-window flag falls back to the static profile, and the UI gained a Tariff
row. Cheap is STRICTLY below the seven-day mean - `<=` would call every hour of
a flat tariff cheap, and 48 h taken on a Friday is two-thirds weekend.
A profile must tile every day type exactly once, checked at startup; a gap is
refused with the range named rather than filled in. `22:00-07:00 mon-fri` does
not cover Saturday morning, and that trap is what the check catches.
validate.py rule 7's stated reason expired exactly as TARIFF-02 predicted: the
test_price.py section 12 tripwire went red naming static_tariff.py. The message
now says what is true instead, and the tripwire is re-aimed rather than removed
- consumer set pinned, expired phrase asserted gone. Rule 7 also grew a second
refusal for static_profile alongside the HA price pair, the same silent-loser
conflict and a live one.
CFG-03 is not widened: static_profile went into price.py's PRICE_OPTION_DEFAULTS
- the one in-code mirror pinned to config.yaml by a check - and the new module
carries no defaults dict of its own.
Measured on the two committed days of this house's real P1 meter. 2026-08-20
(Thursday): 15.220 kWh imported, 9.606 day / 5.614 night, EUR 4.7185 under
day/night vs EUR 4.6725 flat, shifting saves EUR 0.8069 = 9.606 kWh x the
0.0840 spread, derived twice. 2026-08-23 (Sunday): 0.728 kWh, all of it
night-priced, which is the weekend row proving itself. §17 names six Belgian
scenarios; this is the seventh, and it is two days rather than a season - the
file says so rather than implying an annual figure.
All 12 suites green. Eleven mutations of static_tariff.py were each caught by
at least one check.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
616b62d3e9 |
SAFETY-07: cap the loop before it sets the month's billed capacity peak
checks / unit (pull_request) Successful in 3m7s
TARIFF-01 measured the quarter and said the consumer would be this card. It is
one new module, app/peakguard.py, and one new claim.
THE MECHANISM. Every cycle the guard projects the open 900 s block to its
end-of-interval average - from P1 telegrams only, never from the command - and
compares it to a ceiling. Over the ceiling it files ONE arbiter claim: a lower
bound on the setpoint at P_PEAK. That single shape is both behaviours 10.1 asks
for, a hard clamp on charging and pre-emptive discharge, and it cannot cap
discharge or export, because a floor cannot. 9.1's asymmetry becomes a property
of the object instead of a rule to remember.
excess = 900 x (projected - ceiling) / seconds remaining
floor = MEASURED battery power + excess
The 900/remaining gain is 1.0 at the top of the quarter and grows, so the guard
is gentlest where its projection rests on the least evidence. The floor is sized
from delivered battery power, not the standing command: a floor built on intent
re-adds its own unmet ask every cycle and winds to the rail whenever the inverter
fails to follow, and test_peakguard.py part 1 shows the two diverging.
IT TRIPS, AND THE CAPTURES DECIDED THAT. On the healthy reference day it engages
on zero of 95 quarters. The action is level-triggered, unlatched and re-derived
every cycle, so a false engagement costs one cycle of discharge rather than a
parked battery - the cost SAFETY-18 could not bound and this one can. Replayed on
2026-08-20 the billed quarter goes from 5029.8 W, above the inverter's own 5000 W
rating, to 3485 W, under the soft limit and without saturating. Quarters under
the limit across both committed days: 189/190 -> 190/190. Two days is not thirty
and AC 3 remains TARIFF-01's open item.
BLINDNESS IS CHECKED BEFORE THE PROJECTION IS GRADED, and it is a different
action. A fresh averager projects a confident 0 W, which is under every ceiling
there is; a meter gap longer than meter_max_age_s makes the projection read LOW;
a frozen meter reading export projects 0 W at full coverage. All three become a
floor of 0 W - no importing while the billed quantity is unobservable - which is
one-directional and cannot cost pack energy. That is the backstop SAFETY-18 could
not be: its alarm arrives at 300 s of a 900 s quarter and commands nothing. The
frozen term is freeze.looks_frozen() itself, on this cycle's standing command.
THE CEILING IS peak_cap_w, RAISED ONLY BY AN OBSERVED READING. NO_RECORD and
NOT_OBSERVED both leave it at the cap, so an unreadable peak store makes the
guard stricter and never looser. The gate is the reading's STATE, not whether a
number happens to be attached: today a `peak_w is not None` test behaves
identically, and depending on that coincidence is how a future last-known-peak
field would raise the ceiling off a read that failed. headroom_w() is
deliberately not consumed - cap minus peak turns a zero peak into FULL freedom.
TWO DEFECTS FOUND BUILDING IT, both in the interaction rather than the
arithmetic, and both caught by running the thing rather than by reading it:
* A LIMIT does not out-vote another LIMIT. arbiter.resolve() applies every
limit at or above the winner's priority and takes the most restrictive, so
the peak floor (lo >= 0) and the maintenance charge-only shaping (hi <= 0)
resolved to a CONTRADICTION and 0 W - the battery parked in the exact quarter
it should shave. Fixed by suppression, not priority: main.py drops the
maintenance shaping while the guard is engaged, which is what that branch
already did for the optional peak_forecast_entity - a key empty on a default
install, so until now the suspension could not fire on the site that needed
it.
* Thresholding `excess > 0` released the claim the instant it began working,
producing seventeen engage/release cycles in one 900 s quarter and leaving
that quarter 49 W over the limit it had spent fifteen minutes holding. That
is 10.2's oscillation. The threshold is now the floor itself, which is the
same arithmetic read as a level rather than as a switch.
PeakTracker.project() no longer reads a private name with a default.
getattr(averager, "_last_net", 0.0) failed quiet AND disarming - a rename credits
0 W held, the projection reads low, the money guard does not engage.
QuarterAverager.held_net_w is a documented public property now, read without a
default, and Projection carries it. TEST-13 item 4.
NO NEW OPTION AND NO FOURTH DEFAULTS SITE. The ceiling is peak_cap_w, the
coverage threshold is meter_max_age_s, the freeze predicate is meter_freeze_s,
and the achievable discharge comes from max_w and the device rating. config.yaml
and validate.py are untouched; 14's capacity_peak_limit_kw stays declined. On
meter_source: off there are no telegrams, so the guard does not run at all and
the status page says NOT COVERED - running it there blinded it permanently and
stopped every legacy install from charging, which is what the first cut did until
test_clamp.py's export case caught it.
test_peakguard.py: eight parts, all figures derived from the shipped config.yaml
and the committed captures. Part 8 runs seven one-line defeats of the guard and
reports which check bites; six do, and the seventh is reported as NOT caught,
because max(cap, peak) makes a zero peak the strictest ceiling there is and there
is nothing left to catch.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
91ea676af4 |
TARIFF-02: price provider plugins + the canonical all-in price format (#16)
Five providers behind a registry, canonical all-in {start, eur_per_kwh, provisional}. Plugins return RawPoints and declare capabilities().sources; assemble() adds the complement once. register() refuses at import any plugin whose class code mentions a framework key, PRICE_OPTION_DEFAULTS, price_option or _o - closing the three routes review used to double-count. PriceRead.series/no_data as an absence type; all-zero is a series, no_data forbids arbitrage. Additive only: main.py untouched, zero deletions.
|
||
|
|
862f0fa574 |
Merge release/1.0 (TARIFF-01) into TARIFF-02
checks / unit (pull_request) Successful in 2m39s
TARIFF-01 (#17) landed on release/1.0 first, so this branch was two commits behind and Gitea reported the PR unmergeable. Integrating rather than rebasing: the two reviewed commits stay addressable, and the branch is protected against force-push anyway. ONE CONFLICT, AND IT IS THE BORING HALF OF THE ONE REVIEW PREDICTED. Review of #16 expected collisions in four places - the tail of `options:`, the tail of `schema:`, the rule list inside validate_startup_config(), and the tail of validate.py. None of them happened: TARIFF-01 touched neither config.yaml nor validate.py. It added app/tariff.py, test_tariff.py, two P1 scenario captures, and edits to main.py and p1.py, none of which this branch goes near. The only conflict was CHANGELOG.md, where both branches prepended a block under the same `## Unreleased` heading. Both blocks kept, TARIFF-02 above TARIFF-01 since it lands second. Nothing was dropped or reworded on either side, and the resolution adds no line of its own beyond the blank one between them. Checked rather than assumed after the merge: - all ELEVEN test files pass, including TARIFF-01's own test_tariff.py (which this branch had never run) and the 93 s test_loop.py; - the 24-mutation battery still has 0 survivors; - no semantic overlap in config: TARIFF-01's peak tracker reads the peak_cap_w / peak_forecast_entity options that already existed, so the price options added here neither shadow nor duplicate anything. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
e102cde841 |
TARIFF-02 review: close the three other doors to the markup, and stop overclaiming
checks / unit (pull_request) Successful in 2m34s
Review of PR #16 wrote a double-counting plugin four ways. PluginOptions blocked one. The one that decided it touched nothing but PRICE_OPTION_DEFAULTS - a public dict in the module every plugin must already import for register() - so "the number is not in scope" was simply false, and an absolute guarantee a reviewer trusts is worse than a stated limit, because they stop checking. register() now refuses, AT IMPORT, any plugin whose own code mentions a framework-owned name: FRAMEWORK_KEYS plus PRICE_OPTION_DEFAULTS, price_option and _o. code_leaks() parses the class and drops every docstring node before searching, because every plugin is REQUIRED to name its sourced components in prose - engie_dynamic says "markup" in its docstring and a raw text scan false-positives on the documentation the same file mandates. A check that fires on required documentation is a check somebody deletes. test_price.py asserts that a raw scan really would have false-positived, so the strip is proven load-bearing rather than asserted. It fails OPEN if inspect.getsource() cannot find the .py, which the add-on image always can. Refusing to start a battery controller because a static analysis could not run would trade a real outage for a hypothetical accounting error - so instead the checks assert source was found for all five shipped plugins, and a build that lost it is a red check rather than a quietly disarmed guard. All three reachable attacks are written out as plugins in the suite and each must be refused at registration. The cost is measured, not asserted: honest wholesale 0.188, every attack 0.219 - one markup high, every hour, invisible in every log this add-on writes. The guarantee is now stated at its true size everywhere it appears: the framework adds the complement exactly once, GIVEN A CORRECT sources DECLARATION. A plugin that declares {ENERGY} while its feed is all-in still doubles while touching no framework name, and no code can catch that - the declaration is an unverifiable claim about somebody else's tariff. Measured in the suite (0.276) so the limit is a number rather than a caveat. The docstring/declaration check verifies that a plugin's two claims AGREE, not that either is true; that now says so. The three surviving mutations: M3 - _NoData's reason taking a default. This is the identical survivor left open on RIG-01's _Unread.cause: the shape was borrowed from sim/riglock.py including its blind spot, which is what borrowing a shape does if nobody re-runs the mutations against the copy. Closed by SIGNATURE - no constructor or handler of an outcome type may carry a default - so the next one is red without anyone writing a new case. M5 - the ENERGY-required guard was untested. Its consequence is that adds becomes {ENERGY, TAXES} and the emitted price silently omits the energy it is pricing. M7 - deleting the TLS refusal went green AND the check named for it still passed, because the old parser stripped a fixed len("https://") and mangled http://api.energy-charts.info/p into the host pi.energy-charts.info, which then failed the ALLOW-LIST. An assertion that does not test what it names, inside a security check. Fixed on both sides: the scheme is parsed as a scheme, so an http URL now resolves to its real and declared host and only the TLS rule can refuse it; and the check asserts the REASON. Fixing it surfaced M7b - the no-scheme guard was survivable the same way - found by mutating my own fix, and closed the same way. Also carried forward: rule 7's refusal is correct forever but its stated reason ("the provider decides nothing") expires the moment TARIFF-03 or OPT-04 lands. test_price.py section 12 now greps app/ by AST for a load_prices consumer and goes red when one appears, telling whoever lands it to update the message in the same commit. The first draft of that tripwire used a substring and matched the comment in validate.py explaining the tripwire - the same false-positive class as the plugin docstrings, hit twice in one ticket, and fixed the same way. Documented rather than coded around: vars(read).get("points", []) and bool(read) both still get past the absence type, and neither is worth code - defining __bool__ would turn a line that reads like a guard into one that IS a guard by accident, which is how .get(k, default) got here in the first place. Stated plainly in DOCS/CHANGELOG/PR: every fixture is synthetic, so the five feed URLs and JSON shapes are verified against a belief about what those suppliers publish rather than against the feeds. A wrong shape degrades to no-price-data, not to a wrong price. Review's own DST verification recorded: 149,040 hourly instants, 2020-2036, zero mismatches against zoneinfo. The residual is political, not arithmetic, and the docstring now says so. 24 mutations driven through the suite, 0 survivors. Whole add-on suite green. No deleted lines outside this ticket's own files; main.py still untouched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
0dbd485b5a |
TARIFF-01: measure the month's billed capacity peak, and make it survive a restart (#17)
The instrument SAFETY-07 will read: the highest clock-aligned 15-minute average offtake of the calendar month, persisted in /data/tariff.db across two retention tiers, with a monthly peak that recompute_month() proves has not diverged from the 15-minute tier. Files no claim, applies no clamp, commands nothing.
AC 1 was already built and unwired - p1.QuarterAverager on the base already does clock-aligned 900 s blocks, time-weighted over irregular spacing, offtake-only, per-phase, with the max_hold_s gap rule; verified on
|
||
|
|
f4914a174a |
TARIFF-01: measure the month's billed peak, and make it survive a restart
checks / unit (pull_request) Successful in 2m38s
The 15-minute block average was already built and unwired. p1.QuarterAverager computes clock-aligned 900 s blocks, time-weighted over irregular telegram spacing, offtake-only and per-phase; P1Ingest.blocks was a 96-entry list in memory that a restart erased. So this is the persistence and the monthly reduction, not a second accumulator - a second one would be a second source of truth for the exact quantity the money depends on. BLOCKS, NOT A SLIDING WINDOW. The card says "rolling"; 9.1 bills "the highest 15-minute average offtake" and states its own worked case per QUARTER - one 4998 W quarter moving a monthly peak from 4832 to 5013 W. A trailing window reports a peak the meter never bills, and reports it HIGH: a burst straddling :15 fills the window completely while contributing to two block averages at partial weight. DELIVERED, NOT INTENDED. tariff.py only ever sees P1Sample - the meter's own reading - and never a setpoint. SAFETY-20's open question does not arise for a capacity tariff: the utility integrates the current that flowed. AN UNREADABLE STORE IS NOT A ZERO PEAK. peak() answers OBSERVED / NO_RECORD / NOT_OBSERVED with peak_w None unless observed, which is riglock.holder()'s fix applied to something that spends money. A peak read as 0 W hands SAFETY-07 maximum headroom and disarms the guard at the moment its own storage breaks. Restart mid-block resumes the accumulator through a new snapshot()/restore() pair, checkpointed every 15 s and cleared in the same breath as a block close. The held sample keeps its ORIGINAL timestamp, so an outage is integrated under the same max_hold_s rule a running process would apply. quarter_start is the primary key and a re-bank may only ever RAISE a figure. Calendar months are LOCAL: a quarter starting 22:15 UTC on 31 August bills in September. No new option (the limit is the existing peak_cap_w), so config.yaml and validate.py are untouched and CFG-03 is not widened. No second peak entity: peak_forecast_entity stays the input to maintenance_charge_floor(), because repointing that consumer changes what moves energy and belongs to SAFETY-07. AC 3 is NOT met. It asks for 30 days of replay; two days of this house's real meter exist and are committed here. test_tariff.py part 9 replays them, reports the percentage next to the sample size in days, and asserts nothing about 95 %. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
852fc7ced6 |
TARIFF-02: one canonical price format, and a seam that keeps supplier names out of the optimiser
checks / unit (pull_request) Successful in 2m33s
Five provider plugins - generic_dayahead, engie_dynamic,
totalenergies_dynamic, eneco_eddy, manual_csv - all emitting exactly
{"prices": [{"start", "eur_per_kwh", "provisional"}]}, tz-aware at the
Brussels offset, EUR/kWh, all-in. Nothing consumes it yet; the seam
lands first, per the PM's ordering.
It is built in goodwe_controller/app/ rather than at specs.md 2.2's
ems/ingest/prices/, per the product owner's decision of 2026-08-30. The
behaviour 9.3 / 8.3 / 11.4 specifies is unchanged.
Three things shape the design, and each is the mechanism rather than a
comment saying to be careful:
Double-counting the markup is unreachable. A plugin does not return a
price - it returns the figure its source published and declares which of
{energy, markup, taxes} that figure already contains. assemble() adds
the complement, once, in the framework. A plugin is never handed
price_markup_eur_kwh: PluginOptions raises FrameworkOption on it, so the
line that adds the margin a second time cannot be written. Engie and
TotalEnergies publish a retail figure with their margin inside; adding
the configured 3 c/kWh on top would have made every arbitrage decision
wrong by that amount with nothing reporting it.
The product type is declared, not inferred from the plugin's name.
eneco_eddy is real-time/imbalance and gets 8.3's widened thresholds
through capabilities().product and volatility_regime(), never through a
name comparison - which is AC2. test_price.py asserts mechanically that
no plugin id appears anywhere in the framework's code, and drives a
sixth provider defined inside the test file to the right regime with
price.py untouched.
"No price data" is a type, not an empty list - the same rework
sim/riglock.py took under TEST-04. A fetch returns PriceRead.series(...)
or PriceRead.no_data(reason), and only the first carries fields. An
empty series is not constructible; no_data has no .points, no .at(), and
.get("points", []) raises rather than returning the default. A day of
free electricity and a day with no prices are different instructions -
arbitrage is pointless under one and forbidden under the other - and an
implementation returning [] cannot tell them apart. Every site-level
failure returns no_data; nothing raises into the control tick.
Also: injection stays a separate scalar (export_price_eur_kwh, AC4),
negative prices survive the boundary validator (17's regression case),
egress is allow-listed against each plugin's own declaration (16), and
no tzdata is used - the shipped Alpine image has none, so Brussels
offsets come from the EU rule and instants are carried as UTC.
validate.py grows rule 7: an unknown provider id, manual_csv with no
path, and - the HA overlap the PM told us to decide about -
price_provider set alongside price_now_entity/price_avg_entity, which is
two price sources where the HA pair silently wins. The HA sensors are
kept and still work alone; TARIFF-03 and OPT-04 are what replace them.
CFG-03 is not widened: the price defaults have ONE in-code mirror,
PRICE_OPTION_DEFAULTS, which validate.py imports rather than restating
and which test_price.py pins to config.yaml by reading the file.
test_price.py is runnable, assert-free in the house style, and every
verdict it prints is derived. It grades the markup arithmetic with
0.031/0.057 rather than the shipped 0.03/0.06, because 0.06 is exactly
twice 0.03 and a degenerate pair would make double-counting
indistinguishable from correct addition - and it asserts that
non-degeneracy as its first section. The DST checks run on the 23-hour
and 25-hour days, not on a normal day where a fixed 24-slot
implementation and a correct one agree. Thirteen mutations were driven
through it; all thirteen go red.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
9aadf469bc |
TEST-06: pin the cycle() ordering, the NOT COVERED string and the shipped meter_freeze_s (#14)
Closes the three mutations that survived SAFETY-18 suite green. Ordering pinned by consequence (N8 red above the assignment, N3 green below it); NOT COVERED asserted in both directions; shipped meter_freeze_s and its schema bounds pinned. notes_of()/all_notes_of() split so this guard and the whole notification surface are separately nameable, with the three surface-wide claims decided per scenario after SAFETY-03. app/ change is comment-only (AST-identical). |
||
|
|
4b521b2df0 |
ci: trigger a run on the rebased head
checks / unit (pull_request) Successful in 2m33s
No content change. The gate never created a run for |
||
|
|
0942228d65 |
Merge release/1.0 (SAFETY-03) into TEST-06
checks / unit (pull_request) Canceled after 0s
Two conflicts, both predicted, both mine as the later merger. app/main.py - #12 inserted `await self.check_output_clamp()` on the line immediately above `await self.check_meter_frozen()`, so its hunk abuts my comment correction. Resolved so EACH CALL CARRIES ITS OWN BOUNDARY, because the two guards do not share one: - check_output_clamp() reads `self.clamp_last`, which is None until write_setpoint() has run, so its boundary IS the write; - check_meter_frozen() grades `self.target`, assigned further up, so its boundary is the assignment. Letting my correction generalise across both would have been worse than the vague comment it replaces, because it would read as deliberate. The AST of app/main.py is identical to merged release/1.0 (+1251 bytes, all comment). test_freeze.py - #12 independently added `frozen_notes()` keyed on the same id. `notes_of()` subsumes it: same id, plus the title fallback that keeps the id's own check independently falsifiable, plus `all_notes_of()` for claims about the whole surface. THE THREE SURFACE-WIDE ASSERTIONS, DECIDED ONE AT A TIME. Measured on the merged tree: scenario surface ids freeze frozen meter, railed command 2 frozen + clamp 1 TEL-05 converged, -14.2 W 0 - 0 moving meter, a real 8 kW load 1 clamp 0 uncovered transport, no unchanged_s 1 clamp 0 - the wiring scenario STAYS SURFACE-WIDE and now asserts exactly TWO alarms with BOTH IDS NAMED. The answer to "is this still meant to raise one alarm" is no, it raises two, and a third guard has to come back to this line. That is the one assertion in the file that accounts for the controller's entire alarm output; - the CONVERGED case stays surface-wide and stays silent: at the operating point the whole add-on should have nothing to say, that is still true, and narrowing it would give away a real property; - the other two NARROW to notes_of(). The clamp alarm there is correct and is SAFETY-03's subject: a real 8 kW load does drive the loop past the rating, and an uncovered transport does not stop it. Asserting whole-surface silence would make this file fail whenever another guard correctly does its job. Each still owns the load-bearing half - THE FREEZE DETECTOR SAID NOTHING - and the surface is PRINTED so a reader sees what else fired without this file grading it. Re-verified on the merged tree: M1 RED 4, M2 RED 5, M3 RED 3 + RED 2, N6 RED 1, N3 green (correctly), N8 RED 4, R1 RED 2, R2 RED 1. All nine suites green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
6aabb832fc |
SAFETY-03: alarm when a computed setpoint exceeds the rating, do not just clip it (#12)
The clamp already existed; the alarm did not, and specs 10.3 records a silently clipped integrator that reached 14,768 W while every dashboard read a legal 5000 W. OUTPUT_CLAMP now alarms on every engagement, with its own reason code, notification_id, status row and counter, distinct from ordinary saturation. Clamp lives in write_setpoint(), the one path every write takes; the alarm runs after it, out of the write path. Not a trip: the clamped value is written and the loop keeps running. Reviewed over two rounds. Round one held the PR on three findings: clamp_to_rating() returned early from the max_w stage so the device bound was never applied when the first stage engaged (the bigger the overshoot, the less the guard did), and two checks that could not fail - range(CLEAR_CYCLES - 1) issued zero clean cycles at CLEAR_CYCLES=1, and REASSERT_S + 9 passed for any value including an hour of silence. All three fixed in |
||
|
|
d31a12b7c6 |
TEST-06: the id-selection note said 'the only assertion'; there are two
checks / unit (pull_request) Successful in 2m32s
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
2983d7c3b0 |
Merge remote-tracking branch 'origin/release/1.0' into TEST-06
checks / unit (pull_request) Canceled after 0s
|
||
|
|
611d3dbcdf |
TEST-06 review follow-ups: two notification surfaces, the real ordering boundary, the schema bounds
1. notes_of() could not tell this guard's alarm from anybody else's. It selected by SERVICE, so against #12's app/ (which adds goodwe_output_clamp) eight assertions went red, AC1's core check among them. Blanket id-keying is not the repair and was measured, not guessed: selector vs #12's app/ id renamed by service (as committed) 8 red 1 red by id alone 3 red 6 red by id or title (shipped) 3 red 1 red all_notes_of() is the whole surface; notes_of() is this guard's, recognised by the id it should carry OR the title it writes - the `or` is what keeps the one assertion whose subject IS the id able to fail on its own. The three surface-wide claims stay surface-wide, each with a comment naming which surface it is about and why the next guard's author must decide rather than narrow them. They are the three that go red against #12, which is the correct signal. 2. The ordering comment named the wrong boundary. N3 - moving the call to immediately before write_setpoint() - is green and correctly so: self.target is assigned two lines earlier, write_setpoint() clamps only a local and can skip the write entirely. So the invariant is "after `self.target = resolution.target_w`", and the detector grades pre-clamp INTENT, not the wire. Corrected in test_freeze.py and in main.py's own note above the call (comment-only; I merge second and own the conflict). N8 - moving the call above the assignment - is RED 4. 3. The schema range's own bounds are now pinned. int(60,3600) -> int(1,86400) survived green: an operator could set meter_freeze_s: 86400 and the guard is dead with nothing red. Both bounds are re-derived rather than restated. 4. find_hwsim() crashed the whole suite on a checkout one level below the root (HERE.parents[1] -> IndexError, reproduced at C:/goodwe_controller). Guarded. And part 3 now names its transport in the summary: the rig hwsim and the stub are not equivalent - the rig path failed 1 run in 3 - so a green log has to say which one backed it. Also: the "revived transport re-rails" check is labelled a PRECONDITION like its sibling; freeze_rows() records that flipping p1_enabled exercises the row's content and never its gate; and the note about the deleted assertion is corrected - it was REDUNDANT, not undecidable. The reviewer falsified it in one line (move the hass.call above `if not fired: return`, RED 9). "I could not construct a falsifier, therefore it cannot fail" was exactly the inference this file exists to distrust. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
46383c5ae5 |
Merge release/1.0 (CI-01) into SAFETY-03 so the required check can run
checks / unit (pull_request) Successful in 2m32s
Branch protection on release/1.0 now requires the context `checks / unit (pull_request)`, and CI-01's workflow arrived after this branch was cut - so no run had ever been triggered for this PR and the required context would have sat pending forever. Clean merge, no conflicts: .gitattributes, .gitea/ci/Dockerfile and .gitea/workflows/checks.yml only. No add-on source or check is touched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
5e966ca59f | CI-01: this repository's first automated check (#13) | ||
|
|
4e66583a52 |
SAFETY-03 review fixes: both clamp stages always run, and two checks that could not fail
1. BEHAVIOURAL, and a regression this PR introduced. clamp_to_rating() returned early from the max_w stage, so the device bound was applied only when the rating bound had NOT fired - the bigger the overshoot, the less the guard did. At max_w 5000 against a +-4000 device, +9999 emitted +5000 W, outside the device range, while +4500 was correctly held to +4000. It undid the pre-PR guarantee "never send a value the device will reject outright" and undercut this module's own case for max_w-not-min(), which rests on that stage catching a validation that did not run. Both stages now always run; the result names both bounds when both bite (max_w+device). Asserted over a 492-point sweep, because the defect was invisible to any single-value check sitting inside one stage. 2. The hysteresis check issued range(CLEAR_CYCLES - 1) clean cycles, which at CLEAR_CYCLES = 1 issues zero, passes, and prints "0 clean cycles do NOT clear it" - green for the chatter setting the constant exists to prevent. Now: ONE clean cycle must not clear the alarm, a literal that does not move with the constant, and the de-assert count is measured by looping until it clears. 3. The re-assert check stimulated at REASSERT_S + 9, green for any value including 3600 - the hour of silence the module promises not to produce. Now stated in wall-clock terms: a loop pinned across the 900 s capacity-tariff quarter must speak at least 5 times and on no more than 20% of cycles. Pinned in both directions. Red confirmed for each: the restored early return (3 checks), CLEAR_CYCLES = 1 (1), REASSERT_S = 3600 (1) and REASSERT_S = 0 (3). Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c34b5a2922 |
TEST-06: close the three gaps that survived SAFETY-18's suite green
None of the three is a bug in the shipped code. They are gaps in what the
suite could detect, and the next person to touch freeze.py had less
protection than the passing count implied.
1. WHERE check_meter_frozen() runs in cycle(). Moving it to the top left
the whole file green. Pinned by CONSEQUENCE, not by source order, so a
refactor that keeps the semantics stays green:
- the alarm must land on the SAME cycle the command reaches the rail
(at the top it grades the previous command against this cycle's
meter and arrives a cycle late);
- the dead-poll-task composition: poll task dies, stale_input_s is
crossed, the arbiter commands 0 W, and on THAT cycle the alarm is
already clear - because the detector ran after the 0 W write.
wired() now returns a per-cycle trace, which is what makes "on which
cycle" an observation rather than a hope.
2. The NOT COVERED status row. The old check only asserted that an
uncovered transport is SILENT, which a page claiming `armed` on a guard
that cannot run also satisfies. The string is now asserted in both
directions: the uncovered row must say NOT COVERED, name the
meter_source and homewizard_local, and warn; the covered row must still
say armed, or "does not say armed" would be satisfied by deleting the
armed branch.
3. meter_freeze_s. Pinned in test_validate.py by MAINT-04's regex
technique (no PyYAML in the image), and in test_freeze.py by its
consequences: the shipped value drives the replays, must stay inside
the 900 s billing quarter, and 3600/hold_s must stay inside the shipped
deadband. A Controller built with the key ABSENT must land on the same
number, which pins main.py's fallback without touching CFG-03.
All three demonstrated red before being accepted green, and every new
check was mutated to confirm it can fail; one candidate assertion ("no new
notification while parked at 0 W") was DELETED because no mutation could
break it, and replaced by the exact notification count across a revived
transport, which can.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC
|
||
|
|
9c1a23328a |
CI-01: this repository's first automated check
checks / unit (pull_request) Successful in 2m39s
Before this commit `admin/goodwe-addon` had no `.gitea/workflows/` directory at all. Eight runnable test files - `test_loop.py` alone drives the real `run_control()` for 93 s of wall clock - and not one of them had ever been run by a machine. Every merge here was a human reading a diff, and the product owner's requirement that a green CI gate a merge could not be met on a repository with no CI to be green. One job, `unit`, with no `paths:` filter, so it reports on every PR and can therefore be a REQUIRED status check: Gitea leaves a required context it never receives pending forever, which is the failure mode on the other side of this ticket. Concurrency is scoped per PR from the start rather than to a bare group name - the bare name is what let the infra repo's run 521 be superseded while still pending, so its four jobs concluded `cancelled` with `started_at` at the Unix epoch and its PR merged on no evidence at all. The tests run in `.gitea/ci/Dockerfile`: `alpine:3` plus `py3-aiohttp` and `py3-paho-mqtt` from apk, matching goodwe_controller/Dockerfile exactly, because pip would install glibc wheels of a library the shipped image gets from Alpine. The runner itself cannot host them - bare python3, no aiohttp, no pip - and mutating a shared long-lived runner with `apk add` is invisible to anyone reading this repo. Two things measured while building it and recorded in the file rather than learned again: the checkout must sit two levels below the mount root or test_freeze.py's `find_hwsim()` dies on `IndexError: 1` before its first assertion, and test_freeze's hwsim section is silently absent here because admin/goodwe is private - so its PASS is a weaker claim than it looks, and the file says so. Verified green on release/1.0 content before this workflow was written: 8 of 8 files pass, ~4 minutes. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
c040aac4b8 |
SAFETY-03: alarm when a computed setpoint exceeds the rating, do not just clip it
The clamp was never the missing half. specs.md 10.3 records an unclamped integrator climbing ~130 W per 4 s past 10 kW and reporting 14 768 W pinned at the 5 kW rail; clipped silently that is a flat, legal-looking 5000 W hold and nothing says the loop asked for three times it. write_setpoint() - the one path every write takes - now clamps to the VALIDATED max_w and reports whether the raw value differed; check_output_clamp() raises OUTPUT_CLAMP as a notification, an ERROR, an event row and a red status banner. Not a trip: the clamped value is written and the loop keeps running. The rating is max_w and nothing is min()ed at runtime - CFG-01 already refuses a max_w outside the device range at startup. The device range is applied second as defence in depth; it cannot bite after a successful validation, so if it ever does it alarms too and names the bound. No new config key. Decision grew i_clamped / clamped booleans, and that is the load-bearing part: `reason` is one string that slew-limiting and the saturation freeze overwrite, so an alarm keyed on it is silent on exactly the cycles a winding loop produces. Mutating main.py back onto the string drops the 10.3 replay from 2 engagements to 0. Distinct from saturation by construction - no shared reason code, notification id, status row or counter - and checked in the negative, after first asserting the saturation freeze really did engage. Two things found by running it rather than by reading it: a row per engagement flushed the 40-row event log and evicted SAFETY-18's own METER FROZEN? row (now coalesced per episode with an exact count), and a naive clamp turns a nan into a command at the full rating because every comparison against nan is False. test_clamp.py is new: assert-based, no framework. Six author mutations reproduced red, including "clamp kept, alarm deleted". Two of the check's own hypotheses about the freeze/clamp interaction were refused by its sweep and rewritten to what it measured. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
0cdaa3bd3e |
SAFETY-18: alarm on a meter frozen at a wrong-but-fresh value (#11)
A meter answering 200 OK with a document that never changes reads healthy to every freshness mechanism in the stack while the loop rails. Detected by a conjunction - unchanged_s >= meter_freeze_s AND |command| within 5% of max_w - which fails in both directions for independent reasons. Alarm only: no claim, no latch, no 0 W. Reviewed: all six author mutations reproduced red (redder than reported), four more added, three survivors recorded for follow-up. Capture figures re-derived independently. Attack point 4 (dead poll task) measured, not just reasoned. Known follow-up: a device rating that clips max_w by >5% silently disarms the rail term while the status page says armed - does not affect the live install, where dev_max == max_w == 5000. |
||
|
|
7cde5d862a |
Merge release/1.0 into SAFETY-18 - CHANGELOG only
MAINT-04 (#10) landed on release/1.0 mid-review, so both branches had prepended a stanza. config.yaml and DOCS.md auto-merged clean; only the CHANGELOG needed a hand. Both stanzas are kept verbatim, MAINT-04's Unreleased above the new 0.5.2 - no text from either author edited. MAINT-04 is unreleased and 0.5.2 is being cut here, so a release manager may want to fold the two; that is an editorial call, not a reviewer's. Full suite green on the merged tree: arbiter, control, loop, maintenance, p1, validate, watchdog, freeze. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |
||
|
|
b0a17474a3 |
MAINT-04: refuse a maintenance charge the ceiling cannot deliver (#10)
Rule 6 and the default change verified; four claimed mutations plus six of my own all reproduce red. The cross-file default divergence is now pinned by a check that fails in both directions, including when someone closes it - verified against MaintConfig-only, one-call-site-refactored, both-refactored and one-literal-silently-changed. |
||
|
|
ffb8ec6373 |
MAINT-04 review: pin the default divergence with a check, not a comment
validate.py's comment said "if config.yaml's value moves, move this and main.py's together" and nothing enforced it - a comment where a check belonged, in a PR that elsewhere proves it knows the difference. test_validate.py now reads main.py and maintenance.py directly and asserts the divergence EXACTLY AS IT STANDS: config.yaml/validate.py at 2000, main.py's two fallbacks and MaintConfig's dataclass default at 2500. It records the mismatch rather than demanding it be closed, so it passes today and goes red if either side moves - including when somebody closes it in main.py, at which point the check and validate.py's block are deleted together. Nothing in a file another ticket owns is touched. The consequence is asserted through the real code as well as the literals: with the key absent the validator accepts, MaintConfig builds 2500 W against a 2000 W ceiling, and the arbiter resolves it to 0 W as a contradiction - the bug rule 6 exists to catch, passing rule 6. Production-unreachable (the Supervisor always supplies every key) but fully reachable from sim/inject.py and the tests, which is where anyone debugging maintenance works. Also: a CHANGELOG section for the upgrade path, covering both the case where the Supervisor re-derives the default and the case where it persisted the old one, since which applies was not verifiable without probing the live install. And maintenance.py's timeout comment said 13.5 kWh where everything else says 13.8 (300 Ah x 51.2 V, DoD 90); SAFETY-18 does not touch that file. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015VXjA3LWccN1rJsk3okyPC |