Commit Graph
315 Commits
Author SHA1 Message Date
glenn schrooyenandClaude Opus 5.5 b06f1fad5f SAFETY-62 review: DOCS exit 3 at the command block (R1); recognise the auto store key (R2)
checks / unit (pull_request) Successful in 8m35s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 00:02:33 +02:00
glenn schrooyenandClaude Opus 5.5 f4f72211a9 SAFETY-60/62: operator tools refuse input they cannot read
checks / unit (pull_request) Successful in 8m31s
predeploy_check.py and rehearse_roster.py now assert a positive property of
their input (a JSON object, most of whose top-level keys are known option or
store keys) and refuse anything else with the shape named. The `ha apps info
--raw-json` wrapper, a truncated or list-wrapped state file and a wrapped
config no longer produce "CLEARED" / "NO FINDINGS" with exit 0.

Also: a clean --no-live-entities rehearsal exits 3, not 0; alloc_sim.py
exits 1 when split-invariance FAILS; decode_bus_capture.py takes several
paths and exits 1 on a file that is mostly not frames.

Graded by the new test_tool_inputs.py; DOCS.md says to pass .data.options.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:27:50 +02:00
adminandClaude Opus 5.5 a45ed06c05 PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0 (#117)
checks / unit (pull_request) Successful in 8m0s
Reviewed at head 1ad4d3a. CI run 830 (attempt 1, pull_request, PR 117 -> release/1.0), 31/31 PASS. Review: #issuecomment-1588, #issuecomment-1589.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:09:28 +02:00
glenn schrooyenandClaude Opus 5.5 1ad4d3a5bb PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0
checks / unit (pull_request) Successful in 8m5s
One runtime merge since 0.11.0 (cccb2fa): TEL-12 (#116), a new optional
list option `pv_entities` beside `pv_entity`. Option surface 76 -> 77, so
a minor bump. config.yaml version and a closed `## 0.12.0` section only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:59:44 +02:00
admin f863ecaa8c TEL-12: several PV inverters, and one absent member is an absent TOTAL (#116)
pv_entity becomes a roster: pv_entities beside it, replacing it, with the SITE total over the roster. One absent member makes the TOTAL absent - never the partial sum of the ones that answered, because a smaller number indistinguishable from a real one reads a week later as 'there was less sun than there was', which is the conclusion OPT-10 exists to test rather than to manufacture. A member honestly reporting 0 W is still summed.

Reviewed on PR 116. Re-run independently: supervisor_shape_probe.py SSG (exit 0, transcript reproduces byte for byte), the owner's real 75-key options blob through Supervisor 2026.08.0's own AppOptions (ACCEPTED, zero drift on any stored value, pv_entities defaulted to []), tel11_pv_trace.py --compare across both trees (every hash reproduces, control 846a10a5b89e unmoved on unset and one), the rejected-design mutant (trace REFUSED 5/5 with the partial sums named), the planted leak N8 (52/26/10 red cells), and eight mutations on fresh purged copies including N5 sum->max at +0 bytes - no survivors. Habit 24's central claim measured: TEL-11's own --compare refuses on every honest run now that release/1.0 is 0.11.0.

Green traced to this PR's own run: 829/1954, attempt 1, event pull_request, path checks.yml@refs/pull/116/head, payload naming PR 116 with base release/1.0 @ cccb2fa, 31 suites PASS in 7m53s - a real execution, not a laundered skip.

Not deployable as merged: config.yaml stays 0.11.0 and the CHANGELOG entry is PKG's call.
2026-09-24 22:41:19 +02:00
adminandClaude Opus 5 0ef9565071 TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner
reported within minutes of it going live that they have several PV inverters
and could configure one - which is ordinary for a multi-string roof, not a
property of one house. `pv_entities` is the roster and the row carries the
SITE total.

⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`,
and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL
ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no
irradiance" conclusion the channel exists to TEST. So `pv.total()` answers
`None` the moment any configured entity is absent: the topic carries HA's own
`None`, the entity goes to `unknown`, the recorder records a GAP. The
alternative (the partial sum beside a contributor count) was implemented and
run as mutation N1b; it loses because the MQTT row is read COLD a week later by
an attribution that would believe it, while the qualifying count would live in a
second entity with its own history. The partial information is not thrown away -
the STATUS PAGE names every entity that reported, with its watts, and every one
that did not, with its reason, because that surface is read LIVE by a human who
wants the diagnostic.

⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is
`is None`, never falsiness - a roster that blanked the site on a zero would
report an absence on every clear evening.

THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list:
tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an
0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and
deepmerge's list strategy is `override` so a `[]` default does not rescue it -
the live add-on would not start. `match(.*)?` does accept both shapes and is
rejected for a different, measured reason: it validates nothing (a string, a
list and the integer 417 all pass) and renders as a plain text box. So
`pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for
`inverters:`, with a status caution saying which key won - a union would
double-count the inverter the old key still names.

STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than
replaced and now grades five claims over three document sets. The control hash
is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the
roster control document is byte-identical between the two trees. 2/5 is a claim
TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly
as 0.11.0 does" is a real cross-tree identity over control AND telemetry.

⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit
24: a discriminator defined as "the baseline lacks this feature" dies on the
release that ships the feature, and dies as a false refusal.

Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B
(`sum` -> `max`, the same three characters) and was run on a fresh copy with
`cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO
contributions in two units with absence driven at EVERY position - a member
contributing 0 W could go absent without moving the sum of the rest, which is
habit 23 with a coinciding value in the arithmetic rather than in the plant.

31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0,
so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG
entry is wanted and deliberately not written - 11b forbids `## Unreleased` and
the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the
material it needs.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:13:25 +02:00
adminandClaude Opus 5 cccb2fa07b PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1 (#114)
checks / unit (pull_request) Successful in 8m1s
Bumps config.yaml 0.10.1 -> 0.11.0 and adds the `## 0.11.0` section, so the Supervisor offers the update that carries SAFETY-56's wording fix and TEL-11's `pv_entity`.

Reviewed at head b11bea7. Green traced to this PR's own run (827, attempt 1, payload names PR 114 base release/1.0, 31/31 real). Version gate 11a-11d, SAFETY-56's behaviour hash and TEL-11's four trace rows all re-measured on this tree and matching. slug unchanged; option surface 75 -> 76 with no validator rule added.

Two non-blocking findings recorded on the PR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 19:20:06 +02:00
adminandClaude Opus 5 b11bea70d3 PKG-17: the SAFETY-57 correction pointed at the wrong paragraph
checks / unit (pull_request) Successful in 8m13s
Self-review. The note added to `### SAFETY-57` said the reading rule it is
qualifying is "two paragraphs up"; it is in the paragraph directly above - the
same one the note follows. A changelog that misdirects a reader to a paragraph
that is not there is the small end of exactly the defect this cut is fixing
three sentences of elsewhere, so it is corrected rather than left.

Text only, one line pair, still two files in the branch's diff.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 19:01:35 +02:00
adminandClaude Opus 5 cfafdffaed PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1
checks / unit (pull_request) Successful in 8m0s
Two files, and no third. config.yaml 0.10.1 -> 0.11.0; CHANGELOG.md gains
`## 0.11.0` and three corrections to sections below it.

A MINOR BUMP, NOT A PATCH. TEL-11 adds an option - `pv_entity`, 75 keys -> 76 in
`options:` and `schema:` together - which is the same test 0.8.0, 0.9.0 and
0.10.0 were cut on. Nothing here can refuse a stored blob: the key is `str?`
with an `options:` default of "", validate.py does not mention it, no default
moved and no enum widened, so a blob that starts the add-on on 0.10.1 starts it
on 0.11.0.

THE TABLE HAS TWO ROWS AND THE WINDOW HAD FOUR MERGES. CI-9's follow-up
(9f6b9f1, `.gitea/workflows/checks.yml` only) and SEC-2 (239e120,
`docs/RELEASE.md` + README.md) are excluded under PKG-15's rule - AUDIENCE, NOT
IMPORTANCE. Neither file is under `goodwe_controller/`, neither is in the built
image, neither is in predeploy_check.py's RUNTIME tuple, and there is no version
of this add-on on which an operator can observe either. SEC-2 is the closer call
and the section argues it in full rather than asserting it: it is the more
consequential ticket of the two - it is why this release is a pull request
rather than a push to master - and it is still a procedure for whoever cuts a
release, not something the person deciding whether to press Update can act on.
Both are named in the section with pointers to PR #102 / checks.yml and PR #108
/ docs/RELEASE.md.

WHAT THE ENTRIES LET AN OPERATOR DECIDE. SAFETY-56: behaviour byte-identical
(6030175ed2ab..., reproduced in the CI image over 2390 capture reads, a 66-cell
grid stepped 120 times and six driven worlds), three surfaces named with the old
and new wording side by side - the STALE_READING line quoted onto the action log
and status page, the SAFETY-37 ERROR log line, and the readiness row that
asserted a false fact about a named entity. TEL-11: unset is byte-identical in
BOTH the control and telemetry documents, set is byte-identical in the control
document only; the three TEL-11 rows of that table were re-measured in the CI
image on this tree (control 846a10a5... twice, telemetry a443a6ce... / 4e6d1cb2...).
It is stated plainly that pv_entity is not a control input and does not change
what the loop does, and that absence publishes `unknown` rather than 0.

THREE CORRECTIONS BELOW THE NEW SECTION, WITHOUT REWRITING HISTORY. The 0.10.1
preamble said SAFETY-56 was open; the SAFETY-57 entry said its accusatory
diagnosis half was "deliberately untouched"; the 0.10.0 preamble left SAFETY-56
with no pointer while SAFETY-57 had one. All three quotations are what the
0.10.1 image actually prints and are left standing - a reader on 0.10.1 has to
recognise them - each now scoped to 0.10.1 and pointed at `## 0.11.0`.

VERIFIED. test_version_gate.py part 11 all four: 11a one contents table and the
slicer closed (302 lines under '0.11.0'), 11b 0.11.0 == config.yaml, 11c all
three RETIRED_PROVIDERS ids named - scoped to a pre-0.10.0 crossing and pointing
at `## 0.10.0`, which is where the evidence is - 11d still exactly one
`## Unreleased` below, PKG-08's, untouched. 31/31 in the CI image, checks.yml's
exact command, purged tree, `:ro`.

Not deployed and not installed. Shipping is a separate pull request from
release/1.0 into master, per docs/RELEASE.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 18:50:13 +02:00
admin 94da37fc72 TEL-11: PV production stops being invisible, and stays out of the control law (#113)
Reviewed on the PR. Green traced to run 825 (PRNUM 113, BASEREF release/1.0, attempt 1, real 8m6s execution). Control-path identity independently reproduced on both trees and counter-tested with a planted leak (red on 26/41 cells); all three of the trace tool substituted refusals fire. M7 genuinely red. Three publication states distinct on the wire. 31/31 in the CI image.

Not deployable as merged: config.yaml stays at 0.10.1, so predeploy_check.py reports a NO-OP until PKG cuts a version.
2026-09-24 15:55:29 +02:00
glenn schrooyenandClaude Opus 5 07ba3433ed TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.

AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.

POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.

ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.

THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.

GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.

IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:

    control   release/1.0 unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      set    846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    telemetry release/1.0 unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      set    4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f

UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.

⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.

Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.

⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.

No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 15:35:07 +02:00
admin 9f6b9f14cd CI-9 follow-up: the summary said "mechanically", the blind spots say otherwise (#102)
Corrects the preamble's claim that the `guard the trigger` step keeps checks.yml filter-free "mechanically". It does not, for blind spots 1 and 3: the guard lives inside the workflow a filter makes Gitea skip, so for those the defence is the comment.

Names the filter that would actually get written - `branches: [release/1.0]`, not `[main]` - because it reads as tightening onto the protected branch, leaves every day-to-day pull request green, and switches off the `release/1.0` -> `master` release pull request that SEC-2 made the mandated path to an installed system. Points the forge fix at both protected branches, not just `release/1.0`.

Reviewed on the pull request. Verified from the branch's bytes: the guard's awk is unchanged and still refuses `branches:`, `paths:`, `paths-ignore:`, `branches-ignore:`, `tags-ignore:`, `types:` and the inline-flow form injected into the `on:` block of the edited file; comment-only at 0 non-comment changed lines, non-comment lines identical 139 == 139; the merged tree differs from c9aaf7f in this one file only. Green traced per CI-10 to run 824 / job 1949, payload PRNUM 102 / BASEREF release/1.0, base c9aaf7f, 30 PASS 0 FAIL.
2026-09-24 14:37:15 +02:00
glenn schrooyenandClaude Opus 5 8f9c2cad57 CI-9 follow-up: the skip direction, written the right way round
checks / unit (pull_request) Successful in 8m37s
`every subsequent pull request matching it is skipped too` is the inverse of
the behaviour. A pull request that MATCHES a `branches:` filter still RUNS;
the one the filter EXCLUDES is what Gitea sits out, reports `skipped`, and the
rollup launders into `success`.

The error arrived with the generalisation in the previous commit: `33e17db`
said "every subsequent pull request is skipped too", which was unqualified and
true for the `[main]` case it described. Naming the wider hazard made a
qualifier necessary, and the wrong one went in - contradicting the paragraph
directly below it, which describes `[release/1.0]` correctly as leaving every
day-to-day PR running and green.

Corrected, and the direction is now stated explicitly with the failed draft
recorded, because this file already carries one instance of the same shape:
"That was wrong, it contradicted the checkout step's own note a few lines
below, and the error was not cosmetic."

Guard re-verified on the edited bytes: passes here, still refuses
`branches: [release/1.0]` added to the `on:` block. Comment-only, 0
non-comment lines changed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 14:27:19 +02:00
admin c9aaf7f04d SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can (#112)
Text only, no behaviour change. Three operator-facing sentences stop asserting a dead register where the gate cannot distinguish a dead register from a pack the BMS is refusing.

Reviewed on the PR: behaviour byte-identical (trace tool sha256 6030175ed2ab reproduced on both trees, plus AST identity with string constants normalised); five mutations re-applied on purged trees, all matching claimed named-red counts; SoC of the live episode independently measured at 11 percent; CI green traced to PRNUM 112 / BASEREF release/1.0.
2026-09-23 21:27:40 +02:00
adminandClaude Opus 5 8a6acd9fa2 SAFETY-56: the gate cannot tell a dead register from a pack that cannot comply, so stop saying it can
checks / unit (pull_request) Successful in 8m0s
Text only. No behaviour change - same conjunction, same limits, same MISSING,
same 0 W, same NOT READY. `tools/safety56_behaviour_trace.py` says so: 2390
capture reads, a 66-cell swept grid, and six driven controller worlds produce
the byte-identical document `6030175e...` on origin/release/1.0 and on this
branch, while the sentences differ.

THE DEFECT. SAFETY-37's conjunction is satisfied by two disjoint worlds - the
register has stopped reporting reality, or the SOURCE cannot comply with the
command - and nothing `freshness.py` is handed separates them. Three sentences
asserted the first. On the live 2026-09-21 episode it was the second: the pack
read 11 % for the whole 850 s hold, every command in that hold was a discharge,
and the register answered the first CHARGE command three seconds later. The
readiness row was worse still, because it asserted a false fact about a NAMED
entity that was present, numeric and updating - so the operator opened
Developer Tools, found it working, and had every reason to conclude the
diagnostics were broken.

THE FIX. Each message states what was OBSERVED and names BOTH explanations.
Three wordings, no shared helper: two are a log line about a behaviour, the
third is a banner about an entity, and a helper serving both would drop
whichever half the other caller does not need. SoC stays STATED, NOT WIRED -
part 11b drives the two worlds at 50 % and 11 % and the sentence does not move
one byte. The row does not branch on `batt_fresh.stale` either: `stale_note()`
already rides `liveness_notes()` a few rows below, so the discriminator is "is
that row there?", and part 11d asserts it is present in one world and absent in
the other.

THE CHECKS. test_freshness.py part 11 builds the pair of worlds with ground
truth written down rather than derived from the published stream, asserts they
are really two (40 of 40 reads differ) while the published stream is
bit-identical, and only then grades the sentences. Eleven mutations, all red:
each of the three sentences reverted (3, 2 and 2 named reds), the two
explanations transposed at ZERO bytes (1), the second explanation deleted (1),
the admission of ambiguity replaced by a ranking (1), all three reverted at
once (5), and two aimed at this card's own check - collapsing the world pair
(2) and emptying the accusation list, which a positive control against the
three sentences as 0.10.1 shipped them catches (1).

AND TWO OF THE ELEVEN FOUND DEFECTS IN THE CHECK RATHER THAN IN THE CODE.
Transposing `label` and `entity` in the row made it unfindable and the run died
on an IndexError - a red with no name and every later check ungraded, FCST-06's
shape exactly; `_s56_row()` returns a named absence now, 0 named reds before, 3
after. And the first invariance run compared a tree with itself, because it
archived a branch whose edits were not committed yet; the tool now REFUSES to
report "behaviour unchanged" unless the sentences halves differ, and both of
its refusals are driven.

SAFETY-57's part 10h check was the handoff and is inverted rather than deleted:
it required the accusation to still be present so that removing it had to be a
deliberate act. This is that act. Its escape clause is untouched.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 21:02:40 +02:00
glenn schrooyenandClaude Opus 5 628279a68a CI-9 follow-up: name the filter that actually gets written, not the one that looks wrong
checks / unit (pull_request) Successful in 7m58s
Three sentences in the blind-spot clause went stale between writing and review.

`no pull request in 99 has ever targeted master` is no longer true: SEC-2 made
`release/1.0` -> `master` the mandated release path and protected `master`
with the same required context, and a PR against that base has run for real.
The census it came from also erases its own evidence - PR #102 was itself
opened against `master` before retargeting, which the /pulls listing no longer
shows, exactly as the caveat 25 lines above this clause warns.

The clause also named `branches: [main]` as the hazard. That is the version
that looks wrong. The one someone would actually write is
`branches: [release/1.0]` - it reads as tightening onto the protected branch,
every day-to-day PR keeps running green, and the only thing it switches off is
the release PR whose content reaches an installed system.

And the prescribed fix named only `release/1.0`'s status_check_contexts. Since
SEC-2 `master` carries the same rule, so a reader following it literally would
half-close the hole and believe it shut.

Guard re-verified against the edited bytes: passes on this file (whose new
prose quotes `branches: [release/1.0]` in a comment) and still refuses a real
filter added to the `on:` block. Comment-only: 0 non-comment lines changed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 20:18:50 +02:00
admin 239e120bf6 SEC-2: write down the release path, now that master refuses a direct push (#108)
Reviewed on the PR (issuecomments 1480, 1485, 1488, 1489). Documentation only: docs/RELEASE.md (new, 116 lines) plus a 2-line pointer in README.md's file map. No code, no workflow change.

Verified against the forge rather than accepted from the document:
- Both branch_protections rules re-read field-for-field identical (enable_push false, enable_force_push false, status check `checks / unit (pull_request)`, required_approvals 0, block_admin_merge_override true, no whitelists, no file patterns); master's rule created 2026-09-23T03:09:21; default_branch still master. Section 2's After table is exact. No protection was changed by this review - both rules re-read with their original updated_at.
- The empty-PR 405 trap reproduced independently on my own control (throwaway PR #111 between two same-SHA unprotected branches): empty PR -> 405 "Please try again later"; same PR after one commit -> 409 "head out of date". Section 1's "read the message, not the code" is correct and both messages are quoted accurately. PR #111 closed, branches deleted.
- release/1.0 (b0b24e5) is an ancestor of master (0f14c2a), so a literal release PR is empty right now - PR #109 has 0 commits, 0 files, and Gitea opened it anyway. Section 1's closing note is right.
- A master-base PR gets a genuine CI run, not a laundered skip: PR #107 head cb7e45b3 shows Waiting -> In progress -> success, "Successful in 7m56s", run 814. This PR's own head 9d593429 likewise, run 818.
- All five required steps are present and correctly ordered: work merges to release/1.0 with a version bump in goodwe_controller/config.yaml; release via PR release/1.0 -> master; direct push refused; green check before merge; `ha store reload` after, without which the Supervisor keeps serving the cached version. required_approvals: 0 is stated twice, so no reader can believe the dev/review split is enforced.

One non-blocking defect left open (issuecomment 1485): section 1 calls 0f14c2a "the only commit on master that carries no (#NN) merge suffix". 274 of master's 297 commits carry no suffix. The true statement is stronger - no release has ever reached master through a pull request, and 6f5e8e3 (0.10.0) was promoted by the same direct push one release earlier, so 0.10.1 was the second, not a one-off. Background, not procedure; wants a follow-up line change.

A third comment of mine (issuecomment 1488, merge style) is withdrawn in issuecomment 1489 - it rested on a premise I had not checked and which is false.
2026-09-23 04:08:18 +02:00
glenn schrooyenandClaude Opus 5 9d593429d3 SEC-2: write down the release path, now that master refuses a direct push
checks / unit (pull_request) Successful in 7m56s
master is the default branch, which is what the Home Assistant Supervisor
clones - so whatever sits on it runs on a real 5 kW inverter. Until today it
had no branch protection at all, while every gate this repo built sat on
release/1.0, the branch that does not ship. 0.10.1 went straight onto master
on 2026-09-22 with no PR, no CI and no reviewer, and it succeeded.

master now carries the same rule as release/1.0 - enable_push false,
required context `checks / unit (pull_request)`, block_admin_merge_override,
required_approvals 0. That is a forge setting and cannot live in a commit, so
the part that can is this: the procedure it implies. Without it the next
release is attempted the old way and fails confusingly at the push.

docs/RELEASE.md records the path (merge to release/1.0, bump version, PR
release/1.0 -> master, wait for green, merge, then `ha store reload` before
the Supervisor offers anything), the before/after protection state of both
branches, and how the gate was proven to bite rather than merely badge green.

Documentation only - no code, no workflow change.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-23 03:43:37 +02:00
admin b0b24e5d41 PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0 (#105)
checks / unit (pull_request) Successful in 7m57s
Reviewed on the PR (issuecomments 1455-1462): identity verified unchanged (slug goodwe_controller, no image: key, installed slug 68285ac7_goodwe_controller corroborated from HA backup metadata); version-gate 11a-11d re-implemented and verified independently; the 16-of-93-at-790s pairing re-derived from the committed 16-day capture (>=710: 17, >=790: 16, >=815: 15); the SAFETY-57 entry verified as a faithful move carrying only the three declared #104 documentation fixes; corrected 0.10.0 preamble corroborated to the day against backup metadata; suite 30/30 reproduced with checks.yml's exact command. Two files, no control code. The 710 s/790 s split between test_freshness.py and this file is a known, stated gap and takes its own card.

NOTE: master (the Supervisor's default branch) is still 0.10.0 and still lacks SAFETY-57. This merge does not deliver; bringing master to release/1.0 is a fast-forward and is the remaining step.
2026-09-22 15:52:25 +02:00
glenn schrooyenandClaude Opus 5 eb88646899 PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0
checks / unit (pull_request) Successful in 8m0s
The Supervisor decides an update exists by comparing config.yaml's version
string with the one the box reports. master and release/1.0 both said 0.10.0,
so SAFETY-57 - a deadlock that parked the reference battery for ~13 min on
2026-09-21 while the house exported 2.4 kW - had no way of reaching the box
that has it. A patch bump is the delivery mechanism, not bookkeeping.

- config.yaml: 0.10.0 -> 0.10.1. Nothing else in the option surface moves:
  no key added or removed, no default changed, no enum widened, no rule added
  to validate.py, so a blob that starts on 0.10.0 starts on 0.10.1.

- CHANGELOG.md: a new `## 0.10.1` section, holding SAFETY-57's entry moved out
  of `## 0.10.0`. The entry opened by saying it was misfiled and that whoever
  cut the next version owned moving it; this is that cut, so that paragraph is
  replaced by what an operator actually needs in order to decide - what the
  deadlock does (command parked at 0 W, batt reading gated to MISSING, escape
  condition unreachable from inside the state), how to recognise it (setpoint
  stuck at exactly 0 W with the battery register flat, a STALE line and no
  clearing line) and that a restart of the add-on clears it.

- PKG-16 proper: `## 0.10.0`'s preamble still claimed 0.10.0 "has never been
  built or pulled anywhere" and that the reference install was on 0.7.0. Both
  stopped being true on 2026-09-20 ~22:18 CEST, when 0.10.0 was installed as a
  repository add-on (slug 68285ac7_goodwe_controller) and began regulating a
  real battery. The section's own bump argument was explicitly conditional on
  that; the condition has fired, so the argument is retold as history and the
  section is closed. This text is what the Supervisor shows beside Update.

Also fixes, in this file only, the three non-blocking documentation defects
raised on PR #104 - issuecomments 1445, 1446 and 1447:

- 1446: the live episode is 790 s, not 710 s. Re-derived rather than rescaled:
  at >= 790 s the committed 16-day replay gives 16 of 93, not 17.
- 1447: the BMS keep-alive pulse was an inference stated as a measurement. No
  committed capture identifies one, and on this episode 0x0518 never moved at
  all. The measured claim replaces the firmware story.
- 1445: "neither consumer can reach a verdict inside one window" is universal
  as written and graded on a fixture that puts the obligation back on every
  release. It now carries the qualifier the reviewer asked for, and names the
  unbounded case and why the shipped one-inverter roster cannot reach it.

The same three defects also sit in app/freshness.py, test_freshness.py,
DOCS.md and the DECISIONS note. They are deliberately NOT touched here: this
PR is config.yaml and CHANGELOG.md only, and none of them is worth delaying a
live safety fix. SAFETY-56 and SAFETY-58 are likewise untouched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:22:03 +02:00
admin b9f7bd0506 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested (#104)
Reviewed and merged by the PR review agent. Acceptance criterion re-driven independently off the committed RS-485 capture: the verdict is withdrawn with 0x0518 held constant at -3 W, no external change. Counterfactual release_s=inf verified byte-equivalent to the shipped-before module over 242336 reads, so the SAFETY-37 conjunction is untouched. 30/30 suite green in checks.yml's own image; 11 mutations re-applied on a purged tree; the argued-equivalent M7 proved equivalent over full internal state.

Three non-blocking documentation findings filed on the PR (comments 3/7, 4/7, 5/7) for a follow-up before the next version is cut.
2026-09-21 15:49:35 +02:00
adminandClaude Opus 5 43c144b8d9 SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.

REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:

  10:51:24.7  0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
              the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
  10:51:29.7  the command reaches +1060 W - 800 W of travel
  10:52:00    the conjunction arms. Inverter.batt becomes None
  10:52:21.7  the site commands 0 W, on the wire
  ...         0x0518 does not change value for 850.0 s. The setpoint does not
              change value for 790.0 s. The house exports 2.4 kW throughout
  ~11:04      a human restarts the add-on. That is what ends it

AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.

THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.

THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:

  the verdict is withdrawn when the obligation that produced it has been gone
  for RELEASE_S, and the register is then re-graded from scratch.

RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.

The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.

WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.

Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.

main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.

Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.

Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-21 12:33:56 +02:00
adminandClaude Opus 5 6f5e8e378a PKG-15: bring release/1.0 to master at 0.10.0, so the default branch is the add-on
`master` has been `5184a2c` / v0.2.1 since 2026-08-25 - the tree that drives the
house - while every ticket since has landed on `release/1.0`. Three consequences
were live, and all three are what this merge closes:

 * `master` is the DEFAULT branch, so Gitea indexes dispatchable workflows from
   it. `master` had no `.gitea/` at all, which is why `GET /actions/workflows`
   answered empty and the UI's dispatch button was missing.
 * new pull requests default to `master`. #102 was opened against it by
   accident and its first run graded the change merged into a stale `master` -
   an honest-looking green answering the wrong question.
 * AND THE ONE THAT NOW MATTERS MOST: the repository has not yet been added to
   Home Assistant, and adding it is part of this release. `master` is the
   branch the Supervisor will read the moment it is added, so whatever stands
   here is what it shows and offers to install. This merge is what makes that
   0.10.0 rather than 0.2.1.

NO CONFLICT WAS POSSIBLE AND THAT WAS CHECKED, NOT ASSUMED. `master` is a
direct ancestor of `release/1.0` (`git merge-base --is-ancestor` true), the
merge base IS `5184a2c`, and `origin/release/1.0..origin/master` is empty -
`master` carries nothing `release/1.0` lacks. `--no-ff` is used anyway, so the
crossing from 0.2.1 to 0.10.0 is one addressable commit rather than a pointer
move.

WHAT CROSSES: config.yaml 0.2.1 -> 0.10.0. The add-on the Supervisor will build
is a different program from v0.2.1 in the ways `goodwe_controller/CHANGELOG.md`
sections 0.3.0 through 0.10.0 describe - among them P1 meter ingestion, the
separate integrator the velocity form did not have, shadow mode, the tariff
plan and the multi-inverter roster. The ROLLBACK POINT does not move: tag
`v0.2.1` still names `5184a2c` and still names the tree that ran the house.

NOT A DEPLOY. Nothing is installed, no `ha addons update` is run, `/addons/` is
untouched and neither 192.168.2.158 nor 192.168.2.221 was contacted. Adding the
repository to Home Assistant, and pressing Install, remain the owner's call.

Verified before merging: the full suite in the CI image on `release/1.0`'s tree
- `cp -a`, purged, `:ro` mount, one file at a time, exactly the command in
.gitea/workflows/checks.yml - 30/30, exit 0; and PR #103's own
`checks / unit (pull_request)` was a real `success` on the merge, not a skip.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
v0.10.0
2026-09-20 12:34:30 +02:00
admin 8a5736136a PKG-15: fold TEL-10 and SAFETY-48 into 0.10.0, so the version names its contents (#103)
Reviewed and merged by the PKG-15 review agent.

Verified rather than accepted:
- test_version_gate.py 11d pins `## Unreleased` blocks below the newest section at exactly one; deleting the block goes red (reproduced on a copy of the tree).
- 32 runtime commits since 86bdf49 and 24 accounted by the contents table, re-derived with predeploy_check.py's own RUNTIME rule; PKG-14's superseded 28/21 were correct when taken.
- app/validate.py imports neither main nor mqtt (read by AST), and SLEW_RAIL_FRAC / LOOP_TICK_S / PLANT_SETTLE_S are byte-identical across cb3f686..HEAD, so PKG-14's CLEARED transcript still holds.
- CI-9 (16b1d6c) touches only .gitea/workflows/checks.yml, outside the built image and outside RUNTIME.
- The SAFETY-48 entry keeps the capacity-tariff misreading out: no worst-quarter row in the A/B table, and the 3739 -> 3434 W figure appears only inside the paragraph that disclaims it.

Three non-blocking defects posted on the PR: the gain:0.3 / slew-rail tie values are swapped against DECISIONS/SAFETY-48; "touch three files between them" should say three runtime files; and the stated reason cb3f686 enters the count ("last..HEAD excluded it") is wrong, though the count is right.
2026-09-19 19:08:05 +02:00
adminandClaude Opus 5 5aba220046 PKG-15: fold TEL-10 and SAFETY-48 into 0.10.0, so the version names its contents
checks / unit (pull_request) Successful in 7m53s
0.10.0 was cut by PKG-14 on 2026-09-16 and three tickets have merged into
release/1.0 since. Two of them change the built image - one is a CONTROL LAW
change and one adds three MQTT entities - and neither is described anywhere in
this file. Tagging that tree today would stamp a number on contents the
changelog does not account for.

FOLDED RATHER THAN CUT AS 0.11.0, AND THE ARGUMENT IS CONDITIONAL.
0.10.0 has never been built or pulled anywhere: the reference install is on
0.7.0 (PKG-14's own predeploy run records `deployed on the box : 0.7.0`), the
repository carries exactly one tag, `v0.2.1`, and no release. So the string
`0.10.0` does not yet name a tree anyone is running, and the PKG-06/PKG-07
no-op that forbade re-cutting `0.9.0` does not reach it. Cutting 0.11.0 would
burn a number on a release that never left the repository. The condition is
checkable and the section now says so: run against a box already reporting
0.10.0, `tools/predeploy_check.py` refuses with THE DEPLOY WOULD BE A NO-OP and
names the runtime commits since the bump. `config.yaml` stays at 0.10.0, so
`test_version_gate.py` 11b still finds the two sides equal.

SAFETY-48 IS THE ENTRY THAT MATTERED MOST TO GET RIGHT, AND WHAT IT PROMISES
IS LESS EXPORT - NOT A LOWER BILL. The measured result is export 39.61 -> 34.07
kWh over the committed 16-day replay, 14 % of the replayed figure, falling at
every plant and tuning variant swept (~4 % to ~16 %, median near an eighth).
The section says in its own heading and its first line that the control law
changed, and it says PLAINLY that the billed quarter is not a claim: at every
plant lag <= 5.0 s - including the one that best reproduces the recorded export
- release/1.0's worst quarter is ALREADY 3434 W and this changes it by exactly
zero. The 3739 -> 3434 W headline exists at the single longest fitted lag, and
the lag is not identified by the recording. The costs are in the entry too: the
cap moves a saturation-frozen integrator on 1095 of 79 160 frozen ticks, 679 of
them outward; SAFETY-13's settle values moved; SAFETY-39's "the slew does not
own the over-absorption" is now false.

TEL-10 gets the three site rows, what each one is, and the two things a reader
would otherwise get wrong: the lead is NOT a subtraction of two published rows,
and `Loop reason` is not the `Why` row. It repeats neither of the two sentences
TEL-10's own review retracted - EIGHT messages stay first and the ninth,
`goodwe_ctl/availability`, is byte-identical but deliberately moves to last.

CI-9 IS DELIBERATELY NOT IN THIS FILE, AND THE OMISSION IS WRITTEN DOWN RATHER
THAN SILENT. It changes one file, `.gitea/workflows/checks.yml`, outside
`goodwe_controller/` entirely: not in the built image, not in `is_runtime()`'s
list, and not observable on any version of the add-on. This file is the release
note the Supervisor shows beside the version number, and a row here has to be
something the person deciding whether to press Update could act on. The note
above SAFETY-48 says so and says the rule is about audience, not importance.

THE STRAY `## Unreleased` AT LINE 1777 IS NOT TOUCHED, AND THAT IS A DECISION.
It is the 0.8.0-era block PKG-14 annotated: every row in it has shipped, the
annotation says which release each went to, and re-filing it is PKG-08's card.
It is also load-bearing - `test_version_gate.py` 11d pins the count of
`## Unreleased` blocks below the newest section at EXACTLY one, so deleting it
is red on the commit that does it, and so is adding a second.

TWO MEASURED FIGURES IN PKG-14'S PROSE WENT STALE AND ARE RE-DERIVED, NOT
ADJUSTED. The runtime-commit count since `86bdf49` is now 32, not 28, of which
the contents table accounts for 24, not 21; both re-run through
`predeploy_check.is_runtime()` itself. The other eight are the three misfiled
tickets (SAFETY-43 x2, SAFETY-44 x3, TEST-21 x2) and `cb3f686`, PKG-14's own
bump, which edits `config.yaml` and so counts as runtime - it was HEAD when
PKG-14 measured and is inside the range now.

PKG-14's `CLEARED, exit 0` predeploy transcript was NOT re-run and now carries
the check that says why it still holds: `config.yaml` is untouched by both
tickets; `app/validate.py` imports neither `main` nor `mqtt`, and the three
names it takes from `control` - SLEW_RAIL_FRAC, LOOP_TICK_S, PLANT_SETTLE_S -
are byte-identical across cb3f686..HEAD.

Verified: the full suite in the CI image, `cp -a` of the tree, purged, `:ro`
mount, one file at a time, exactly the command in .gitea/workflows/checks.yml -
30/30, exit 0. No runtime file is in this diff.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 18:49:09 +02:00
glenn schrooyenandClaude Opus 5 33e17dba0e CI-9 follow-up: the summary said "mechanically", the blind spots say otherwise
checks / unit (pull_request) Successful in 7m57s
The residual-risk paragraph at the top of checks.yml claims the `guard the
trigger` step "keeps it that way mechanically rather than by asking the next
editor to read this comment". For blind spots 1 and 3 that is not true: the
guard lives inside the workflow a filter makes Gitea skip, so for those cases
the defence IS the comment.

That paragraph is the preamble someone reads at the exact moment they are
editing the trigger, so a summary running ahead of its detail is worse here
than elsewhere. It now points at the blind spots and states spot 3 plainly:
a filter naming a branch nothing targets is itself skipped, lands green and
untested, and then skips every subsequent pull request - the gate off for
everything, silently.

Flagged by the reviewer on PR #95 (issuecomment-1424) as non-blocking.

This PR is also the first real test of CI-9's fix on release/1.0 itself. Run
806 was a workflow_dispatch and posts no commit status at all, so it verified
content but never the gate. This one has to post `checks / unit
(pull_request)` as success rather than skipped.

Verified before push: the guard passes against this edited file (whose new
prose quotes `branches: [main]` and `master`) and still refuses a genuine
filter added to the `on:` block.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 15:53:01 +02:00
admin 16b1d6c422 CI-9: a stacked PR is skipped, and a skipped check clears the merge gate (#95) 2026-09-19 14:55:12 +02:00
adminandClaude Opus 5 ca8fd01819 CI-9: correct the guard comment's grading claim, and name the third blind spot
checks / unit (pull_request) Successful in 7m54s
Documentation only - no change to the guard, the trigger, or any step.

The guard's comment block contradicted itself. It said the pull request that
reintroduces a filter "is still graded by the unfiltered workflow which is on
the base today", while the checkout step's note a few lines below says grading
uses the HEAD's workflow. The head's is correct, and the review measured it on
PR #101: head carrying a filter that excludes the base, base carrying the
unfiltered workflow -> no run, context posted `skipped`, rollup `success`, gate
cleared (409). The wrong version made the step sound like an unconditional
ratchet. What is actually true is narrower: it bites whenever the reintroduced
filter still names the pull request's own base, which is the ordinary case.

That correction exposes a third blind spot, worse than the two already listed.
A reintroduced `branches:` filter that simply does not name the base escapes
the guard entirely, because the pull request carrying it is itself skipped. It
needs no craft - `branches: [main]` from a template, or a tidy-up to `[master]`,
which nothing in this repository's history has ever targeted - and it lands as a
skipped, laundered, untested merge into release/1.0. After that every subsequent
pull request is skipped as well: the gate off completely, not merely the stacked
case leaking.

It is documented, not fixed, and deliberately so. No in-repo guard can close it,
because any such guard lives inside the workflow that gets skipped. Closing it
needs a second permanently unfiltered workflow whose context is added to
release/1.0's `status_check_contexts` - a forge change, the owner's decision,
being put to them separately, and explicitly not a blocker on CI-9.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 14:44:16 +02:00
adminandClaude Opus 5 d2ad080e45 CI-9: guard the trigger mechanically, and re-derive two figures I made up
checks / unit (pull_request) Successful in 7m55s
Review findings on PR #95.

1. Two figures in the header were written under the word "measured" and were
   not measured. "of the 50 pull requests in this repository's history, 49..."
   came from a /pulls call I did not notice was truncated at Gitea's 50-item
   page cap; and "#93 was stacked on TEL-10 five days ago" was invented - #93
   was created 2026-09-19T10:05:00 and merged 11:05:26, the same morning, under
   three hours before CI-9 was opened. Both re-derived from a paged API query
   and now stated with their denominator: 93 pull requests predate this ticket
   (#1..#93, excluding CI-9's own #94..#98), 92 against release/1.0, exactly one
   stacked (#2, TEL-01 -> SAFETY-04). The 92 is flagged as an upper bound rather
   than a census, because the API reports a pull request's CURRENT base and so
   hides any that was opened stacked and later retargeted - which is #93 itself.
   The ratio, and so the cost argument, is unchanged.

2. The fix rested on an invariant - checks.yml has no event filter - that was
   defended only by a comment. Prose has already failed in this exact file:
   9c1a23328a shipped "NO `paths:` FILTER, AND ITS ABSENCE IS LOAD-BEARING" and
   `branches: [release/1.0, master]` in the same commit, eighteen lines apart,
   and that survived 20 days and 84 merges. Adds a step that reads the `on:`
   block of the MERGED checks.yml and fails if it has regained a `branches:`,
   `paths:`, `tags:`, `types:` or any `-ignore` variant. This is not the card's
   option 3 - it does not try to detect its own skip, which is impossible; it
   bites on the pull request that reintroduces a filter, which the unfiltered
   workflow still grades. Two blind spots are named in the step's comment, both
   needing a protection-rule change that is the owner's call.

Also softens "uncloseable from here", which the review judged overstated:
Gitea's acceptance of a `skipped` context is unreachable from this repository,
but the consequence is substantially closeable, and the guard is what closes it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 14:25:22 +02:00
adminandClaude Opus 5 074157c4c2 CI-9: drop the pull_request branches filter, because a skipped check clears the gate
checks / unit (pull_request) Successful in 7m57s
`branches: [release/1.0, master]` meant a stacked pull request - one based on
another feature branch - never matched. Gitea does not stay silent about a
workflow it sits out: it posts the required context itself with state
`skipped`, the combined-status rollup reports that as `success`, and the merge
gate accepts it. Retargeting does not repair it, because the skip is a commit
status on the head sha and so survives the base change.

Measured on Gitea 1.27.3 with throwaway PR #94 against a branch carrying a copy
of release/1.0's protection rule:

  only status is `skipped`   ->  POST .../merge  409 head out of date  (CLEARED)
  no status at all           ->  POST .../merge  405 not all required  (refused)
  status `pending`           ->  POST .../merge  405 not all required  (refused)
  status `success`           ->  POST .../merge  409 head out of date  (CLEARED)

The 409s come from a deliberately wrong head_commit_id in the probe, which
Gitea checks only after branch protection - so a 409 means the request had
already cleared the gate, and nothing was ever merged. `skipped` is the only
state that leaks.

Fixing this at the gate is not possible. Gitea branch protection can require
that a context is PRESENT, never that it is SUCCESS: its whole status-check
vocabulary is `enable_status_check` and `status_check_contexts`, per this
server's own /swagger.v1.json. So the fix has to be upstream - never emit a
skip - which means no event filter.

Cost: every pull request now runs the full ~8 minute suite, including the
intermediate steps of a stack. 49 of the 50 pull requests in this repository's
history were opened straight against release/1.0 and would have run anyway.

Also corrects two things CI-01's header stated as fact. A filter miss is
fail-OPEN, not the fail-closed pending-forever it described; and it is a
skip-ci keyword, not a filter miss, that actually withholds the context and
leaves it pending.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 13:58:58 +02:00
adminandClaude Opus 5 186a044a3a Merge pull request 'SAFETY-48: the slew step ceiling reaches the integrator, and what it bounds is the LEAD' (#93) from SAFETY-48 into release/1.0
Reviewed on the pull request and merged there. Retargeted from TEL-10 to release/1.0 after #92 merged, and NOT merged on the inherited green: retargeting alone left the old `skipped` conclusion attached to a6af332 and the combined status still read success, so the required context was satisfied by a workflow that had never run. Run 799 is a genuine pull_request execution on the merge into release/1.0 - all five steps, the add-on's own tests occupying 08:56:58 to 09:04:47 UTC.

THE CAP MOVING A SATURATION-FROZEN INTEGRATOR IS ACCEPTABLE, NOT MERELY DISCLOSED. The disclosed figures reproduce exactly against the committed capture - 79 160 frozen ticks, 1095 moved, 679 further out on the side they were already on, worst 2424 W - and the worked tick in the comment is present with exactly the numbers written down and is the worst of that subset. What decides it is where the integrator lands rather than which way it moves: on the shipped configuration integrator_max_w is unset, so target == i_w after the bounds and the cap holds |i_w - slewed| to one slew step on every slew-limited cycle, frozen ones included. Measured over the whole 256 251-tick recording the carried integrator never stands more than two slew steps from the command on the wire - 800 W against release/1.0's 9200 W. On the frozen path this replaces an integrator bounded only by integrator_max_w with one bounded at two steps, so the loop is less wound up on those ticks and not more. The same-cycle command cannot be affected at all, the cap moving i_w after slewed is decided.

THE ALTERNATIVE IS REFUSED FOR A MEASURED REASON. Gating the cap with `if frozen: _lead_cap = float("inf")` reproduces all four of section 5's corrected figures - export 34.71 kWh, wasted 3.49 kWh, worst quarter 3434 W, worst observed lead 4961 W. The gate does leave the bound with a hole large enough to make the card pointless.

NOTHING FALSE FOUND. Section 3a's lag table reproduces cell for cell, including the rows that say the peak improvement is absent at every lag at or below 5.0 s; the card does not claim a capacity-tariff benefit and says so in four places. Form A is committed nowhere, so it was rebuilt from section 3's prose alone and reproduces all seven figures - 34.43 / 110.62 / 2656 / 2.99 / 3934.59 / +2.73 / +991.53 - which makes section 3 a specification rather than a summary. The one-sided cap was swept against the two-sided band over 136 080 states on an independent grid: 0 differences, corroborating habit 22's retraction.

MUTATION EVIDENCE RE-DRIVEN, EVERY COUNT EXACT, on purged cp -a trees one file at a time: L2 zero bytes 4+3, L4 one red in test_telemetry with test_control GREEN as claimed, L5a zero bytes 5+5, L6 zero bytes 6+3.

SUITE RE-RUN BY THE REVIEWER on the merge rather than the branch tip: release/1.0 29/29, this merge 30/30, exit 0.

One non-blocking note left on the pull request: "worst case 2424 W" is scoped to the 679 further-out ticks, while the largest move over all 1095 is 4220 W. That case is benign - the cap pulling a stale positive integrator down to follow a charging command, magnitude falling - which is why it is a note and not a finding.

Merging is not deploying. The live install still runs release/1.0's control law and slew_w 400 applied by hand; this merge authorises no deploy.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 11:05:25 +02:00
adminandClaude Opus 5 660d079bf3 Merge pull request 'TEL-10: the loop's integrator stops being invisible' (#92) from TEL-10 into release/1.0
Reviewed on the pull request and merged there. `checks / unit (pull_request)` run 798 is a real execution, not a skip: all five steps ran and "the add-on's own tests" occupied 08:04:51 to 08:12:38 UTC.

CONTROL BEHAVIOUR IS UNCHANGED, VERIFIED MECHANICALLY RATHER THAN READ. goodwe_controller/app/control.py is blob 180f58a on release/1.0 and on TEL-10 alike, same sha256 of contents, and release/1.0 is a direct ancestor of TEL-10 so there is no merge-base divergence for a change to hide behind. The only executable edit inside cycle() is prev_w=self.target becoming a named local, loop_prev, passed to the same call. Three write sites for self.i_w exist and only two have a telemetry counterpart; the third is the arbiter re-seed at main.py:3049, inside the same branch and immediately followed by compute(), so it cannot leave loop_i_w stale. app/mqtt.py appends to SENSORS and discovery_payloads() walks it in order, so every existing entity keeps its index.

SUITE RE-RUN BY THE REVIEWER, on the MERGE rather than the branch tip, in the CI image on a purged tree, :ro, one file at a time: release/1.0 29/29, this merge 30/30, and the stacked SAFETY-48 30/30 against both bases. All exit 0.

MUTATION EVIDENCE RE-DRIVEN RATHER THAN READ, because the previous round's counts were irreproducible. M1 is 5 reds on TEL-10's tree and 4 on SAFETY-48's, exactly as the header says and for the reason it gives; M2 is confirmed GREEN and is reported as a survivor; M7 is -96 B and 10 reds in test_mqtt.py plus 1 in test_telemetry.py; M9 is a zero-byte reordering and 7 reds. Every claimed count exact.

R6's correction is true and not merely made: part 1's headline now says EIGHT and the slice under it asserts eight entity configs, part 3's NINE headline is backed by a full missing/changed diff that does cover all nine, and the unasked-for fix two lines down reads eight against the eight-prefix slice.

Merging is not deploying. Nothing here reached the inverter and no deploy is authorised by this merge.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 10:54:02 +02:00
glenn schrooyenandClaude Opus 5 a6af332048 SAFETY-48: what the lead cap actually does to a frozen integrator, and what the peak figure depends on
checks / unit (pull_request) Successful in 7m55s
Four review findings, none of them in executable code. The control law, the
tests and the instruments' arithmetic are untouched; every number below was
re-measured against the committed 16-day capture before it was written down.

R1 - app/control.py carried a justification the decision record and MUTATION.md
habit 22 had already retracted, and it was false about the code it sits in. It
said an unconditional placement "would also pull the integrator toward a
command the SATURATION freeze is pinning", priced at 118 of 256 250 ticks. The
118 was measured against a different pair; on the pair the sentence names the
two forms are bit-identical - 0 of 256 246 ticks, re-measured. And the narrow
form that shipped DOES move a saturation-frozen integrator: it runs before the
freeze block and is not gated on `frozen`. Of 79 160 frozen ticks the cap
changes `i_w` on 1095, and on 679 of those it moves it further out on the side
it was already on - putting back magnitude the freeze had just let fall, which
the freeze's own rule forbids. Worst case 2424 W, at prev_w -3400 W, grid
+4697 W, actual -4144 W, sat_count 2 -> 3: the freeze leaves the integrator at
-176 W and the cap drags it to -2600 W. It never overrides a same-cycle refusal
(the freeze clipped on 75 512 ticks, the slew bound on none of them), and that
is stated too. It is also where SAFETY-13's settle values went: gating the cap
on `not frozen` puts test_control.py part 5 back at -1190 W exactly, while part
4(b) does not come back - that one moved for the winding reason.

R3 - the record read its own sensitivity table backwards. `fit_plant()` picks
lag 7.5 s on battery-power RMS, which separates it from 2.5 s by 0.3 %, while
the tool's own printed fidelity measure (export against the recorded 29.43 kWh)
prefers 2.5 s by the whole 35 % gap. Swept properly: at every lag <= 5.0 s
release/1.0's worst quarter is ALREADY 3434 W and this card changes it by
exactly zero. The 3739 -> 3434 W headline exists at one plant. New section 3a
carries the table; the export reduction now leads every summary and the peak is
presented as lag-dependent. The form-A rejection is strengthened rather than
weakened: form A is worse on the billed quarter at every lag where release/1.0
produces a peak at all, and at every top-N cut of the quarters.

R2 - DOCS.md stated modelled watts to the owner as measurement. It now leads
with the export reduction, says the figures are simulated, and says plainly
that no capacity-tariff improvement is promised.

R4 - tools/slew_sim.py --slew narrated "the OVER-ABSORPTION does not move, and
at the slowest slews it is slightly WORSE" while printing a monotonically
falling column. That sentence is TRUE on release/1.0 (reproduced:
958/1107/1133/1058/987/1029/1150/1143/1081) and false under this branch's law
(777/734/663/563/553/507/435/358/321), so SAFETY-39 is not retracted: its
record gets a forward reference, and the script now reads SLEW_LEAD_STEPS out
of the law it imported and narrates from the column it just printed. Both
branches of that narration were driven.

R5 - three counts in the L table were decoration and are re-driven in the CI
image on a `cp -a`, purged, `:ro`, one file at a time: L5 is 5+5 with the
function names exchanged and 5+4 with the branch bodies exchanged (two
mutations wearing one name, now listed separately), L6 is 6+3. The separable-
state count is grid-dependent and three sweeps disagree, so all three are
quoted with their grids and the load-bearing claim is WHERE they separate.

R7 - "a large import answered too weakly" is not what the aggregate shows. Form
A cuts import by 5.45 kWh and export by 5.18 kWh, and paired per tick delivers
8.56 kWh less offtake energy on the ticks release/1.0 was importing. The harm
is a tail redistribution inside quarters that already net to offtake. The
conclusion stands; the sentence is narrowed to it.

Verified: the full suite in the CI image, purged tree, `:ro` mount, one file at
a time, exactly the command in .gitea/workflows/checks.yml - 30/30, exit 0.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 02:37:01 +02:00
glenn schrooyenandClaude Opus 5 03ef61fa3b SAFETY-48: the slew step ceiling reaches the integrator, and what it bounds is the LEAD
`compute()` freezes the integrator with an asymmetric rule and the comment
beside it states the requirement outright - "the requirement is that the
INTEGRATOR stop accumulating, not only the command" - but `frozen` is computed
from ONE signal, `abs(prev_w - actual_w) > saturation_w`, and slew-limiting
never enters it. The integrator moves `gain * error` a cycle and the command
moves at most `slew_w`, so the integrator outruns the command whenever
`|error| > slew_w / gain`: 667 W at the live shape, against a measured median
grid error of 1114 W at the onset of a recorded episode. SAFETY-39's retune
made it MORE frequent, not less - a smaller step is a lower threshold.

⚠️ THE FORM THE CARD ASKED FOR RAISES THE BILLED QUANTITY, WHICH IS WHY IT IS
NOT WHAT SHIPPED. Reusing the asymmetric freeze on a carried slew flag was
built from release/1.0's own source and measured over 16.00 days / 256 252
meter instants of the live install's recorder: export 39.61 -> 34.43 kWh, and
the worst quarter-hour average OFFTAKE 3739 -> 3935 W with the mean quarter
+2.73 W, in five of six plant and tuning variants. A frozen integrator stops at
`prev + gain*error`, which undershoots by (1 - gain); for an export that is
free and for an import it is offtake, for as long as the ramp lasts. The card
said "do not invent a second rule"; the measurement says to, and both sentences
are recorded.

WHAT SHIPS BOUNDS THE LEAD AT ONE SLEW STEP, inside the branch where the slew
actually bound. Same 16 days, same ticks, same disturbance, same plant, same
seed: export 39.61 -> 34.07 kWh, wasted throughput 4.67 -> 3.19 kWh, battery
sign reversals 2992 -> 2770, median recovery 232 -> 199 s, p99 849 -> 850 s,
max 901 -> 898 s, unrecovered 53 -> 31, worst |i_w - prev_w| 9200 -> 800 W -
and the worst 15-minute average offtake 3739 -> 3434 W, i.e. the billed
quantity IMPROVES. `i_w = slewed` (a cap of zero) is better again at 32.02 kWh
and is refused: it is the velocity form this module's docstring says `i_w=None`
collapses to.

TWO COMMITTED NUMBERS MOVED, DELIBERATELY, WITH THE REASON BESIDE THEM.
SAFETY-13's released command settles at -800 W and -1200 W where release/1.0
settled at -1190 W and -2390 W, because there is less wound integrator to
settle onto; AC 4's property - it stops at the frozen integrator, not the rail
- is what is asserted and the second is now graded against `i_w` rather than a
literal. And SAFETY-39's "the slew does not own the over-absorption" is now
FALSE - INVERTED, on the independent first-order plant test_control.py writes
itself: 1005/1109/1285/1330 W rising with a slower slew becomes 729/550/424/326
falling. Two plant models that share nothing agree on the sign.

Evidence: `tools/replay_recorded_loop.py` plus the read-only capture it made
(scenarios/loop-2026-09-02_2026-09-17). The "before" law is the shipped file
with the block removed by a named substitution - never a transcription - and a
missing anchor is a REFUSAL carrying "NOTHING HAS BEEN MEASURED". The
instrument prints its own fidelity first: it reproduces 39.6 kWh of export
where the install exported 29.4, i.e. it is ~35 % pessimistic about the loop's
tracking, so only the delta is claimed.

30/30 suites green, including test_control.py's exhaustive i_w=None
equivalence sweep against the transcribed release/1.0 law, untouched: the cap
moves `i_w` and not `target`, and that sweep compares (target_w, sat_count,
frozen, reason).

Six law mutations, one instrument battery. L4 - the cap applied
unconditionally, -92 B - was a SURVIVOR of all thirty files: it is
bit-identical on the shipped configuration (0 of 256 246 ticks) and separable
on 2050 of 257 400 swept states, all at `integrator_max_w` above `max_w`, which
part 4 now drives. L5 and L6 are ZERO BYTES.

AND TWO COMMENTS IN THIS CARD WERE INVENTED AND ARE CORRECTED IN PLACE. The
one-sided spelling was justified by a two-sided form that would "drag a
trailing integrator" - it does not, and the two agree on 205 920 of 205 920
swept states; and a "118 of 256 252 ticks" figure had been measured against a
different pair. MUTATION.md gains habits 21 and 22 for both shapes.

NOT DEPLOYED, NOT VERSIONED. The live install still runs release/1.0's law.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 02:36:28 +02:00
glenn schrooyenandClaude Opus 5 b6c6da31d8 TEL-10: two sentences that named assertions this file does not make
checks / unit (pull_request) Successful in 7m57s
Both are review findings on the merged-in-spirit branch, and neither is in
executable code.

R6 - test_mqtt.py part 1's headline said "every one of release/1.0's NINE
messages is still byte-identical and still first". The assertion under it is
`announce(...)[:len(BASELINE) - 1] == BASELINE[:-1]`, which covers EIGHT: the
ninth, `goodwe_ctl/availability`, is byte-identical but deliberately moves to
last, so a prefix comparison cannot include it. Nothing was unguarded - the
`== SITE_NOW` on the next check pins it in its new position - but the sentence
was not the check. Part 3 carried the same mis-statement two lines from a check
that IS about all nine, and is corrected the same way.

R5 - M7's red count was decoration. Re-driven in the CI image on a `cp -a` of
the tree, purged, `:ro`, one file at a time, it is 10 reds in test_mqtt.py and
not 8, on this tree and on SAFETY-48's alike. The direction was right; the
number was inherited rather than re-measured, which is MUTATION.md's reporting
rule 3. A note beside the table now says that a red count is a property of the
SUITE as much as of the mutation and therefore has to name a tree.

Verified: the full suite in the CI image, purged tree, `:ro` mount, one file at
a time, exactly the command in .gitea/workflows/checks.yml - 30/30, exit 0.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-19 02:36:23 +02:00
glenn schrooyenandClaude Opus 5 b548525d10 TEL-10: the loop's integrator stops being invisible
`self.i_w` has been a separate quantity from the command since SAFETY-04 and
has left the process nowhere at all - no entity, no MQTT attribute, no log
line. The investigation behind SAFETY-48 could only RECONSTRUCT it from the
grid trace plus a replay; the reconstruction reproduced about a third of the
engagements it was checked against and was discarded, so the card it was
gathered for had to be argued from a measurement nobody could stand behind.
It could not have been made to work either: `i_w` depends on every cycle
before it, including the ones where the arbiter overrode the loop and
`main.py` re-seeded `self.i_w = self.target`, and that re-seed is invisible in
the grid trace.

THREE SITE ROWS, APPENDED AFTER release/1.0's EIGHT. `loop_i` is
`Decision.i_w` - the accumulator after the cycle, before the output clamp, the
slew limit and quantisation. `loop_lead` is `decision.i_w - prev_w` against the
command `compute()` was HANDED, which is not a subtraction of the other two
published rows: `Setpoint` is the arbiter's output and is this cycle's, so on
any cycle the arbiter overrode the loop the two differ - and that is exactly
the cycle on which the integrator was re-seeded. `loop_reason` is
`compute()`'s own word; the arbiter's `explain()` prints the winning claim's
NAME and has never carried the claim's reason, so `slew-limited` appears in
neither the `Why` row nor `Controller status`. Measured on the same cycle:
arbiter `'loop -> -5000 W'`, loop `'i-clamped'`.

NOTHING IN THE CONTROL PATH MOVED. `app/control.py` is not in this diff.
`compute()`, its returned `Decision` and every constant it reads are identical
to release/1.0, and all nine of release/1.0's retained discovery messages are
byte-identical and still FIRST in the announcement.

Evidence: 30/30 suites green in the CI image. Nine mutations, ONE survivor,
reported as one: `decision.i_w - self.target` for the lead is +2 B and green
because `cycle()` has not reassigned `self.target` at that line - the name is
kept for the coupling, not for a behaviour it buys, and M2b (+8 B) is the
mutation that does change the value and is red.

AND TWO OF THIS CARD'S OWN CHECKS COULD NOT REACH THE FAILURE THEY NAMED.
"the published integrator reaches its bound" was GREEN under the card's named
mutation (publish `prev_w`, -3 B), because the command reaches the bound too -
twelve cycles later. It asserts the LEAD TIME now and is red on 5. "a stopped
controller publishes not-running" was GREEN under deleting that branch's
assignments (-45 B, -67 B), because the fixture STARTED stopped and `__init__`
writes the same values; it stops the controller part-way through a run that
has already wound the integrator to -5000 W. Both are MUTATION.md habit 4,
found by the battery rather than by review.

No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## `
heading that is not config.yaml's `version:`, and opening one would mean
taking a packaging decision this card does not get to take. The operator
account is in DOCS.md and the release note belongs to the next PKG ticket.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-18 23:36:23 +02:00
admin 68c5ede7b9 Merge pull request 'PKG-14: cut 0.10.0, so fifteen merged tickets can reach an install' (#91) from PKG-14 into release/1.0
config.yaml said 0.9.0 while the live box runs 0.7.0 with 0.7.0's files, so it has never received 0.8.0 or 0.9.0 either. 28 runtime commits had landed since the 0.9.0 bump at 86bdf49 with no version to carry them.

MINOR, AND NOT BECAUSE OF THE NUMBER OF TICKETS. A config that is legal on 0.9.0 is REFUSED on 0.10.0: TARIFF-07 retires three price_provider ids and refuses them by name at startup (the ids stay in the schema enum precisely so validate.py's message is reachable rather than an opaque Supervisor rejection); TARIFF-18 moves price_taxes_eur_kwh 0.06 -> 0.11736, and the non-obvious half is the refusal that deliberately does NOT happen, because SUPERSEDED_TAXES_DEFAULTS_EUR_KWH keeps a taxes period table beside a stored 0.06 from becoming exit 78 on upgrade, with the rung measured un-weakened against a genuinely custom 0.1198; SAFETY-10 adds shadow_mode shipped `auto`, where an existing controlling install does not change by one watt and a fresh install comes up observing.

AND A 0.7.0 INSTALL CROSSES 0.8.0 ON THE WAY. `ha addons update` does not walk versions, so 0.8.0's rule 10 lands at the same moment: an explicit slew_w above SLEW_RAIL_FRAC x rail is refused, and 0.7.0's OWN shipped default of 1000 is refused against a 555.6 W ceiling. Measured red on this tree, with slew_w 400 measured green - which is what the live box carries. Someone reading only the newest section would otherwise miss the one release that can stop the add-on starting.

THE BOUNDARY WAS DRAWN HONESTLY RATHER THAN TIDILY. All 18 table rows in the top block merged after 86bdf49 - verified per row with git merge-base --is-ancestor - so the block is genuinely this run's work and was retitled as-is with its 18 `_this branch_` placeholders resolved to merge shas. But 0.10.0 ships MORE than that table lists: SAFETY-43 and TEST-21 are documented in a SECOND `## Unreleased` block sitting below 0.9.0, and SAFETY-44 - which changed app/main.py and app/store.py - is in CHANGELOG.md NOWHERE AT ALL. All three are named in the 0.10.0 preamble rather than moved, because re-filing is PKG-08. The second block is annotated, not rewritten or emptied: UX-02 in it shipped in 0.9.0 and is already in 0.9.0's own contents table, while the other three shipped here. Verified independently before merge: all 30 changelog deletions fall inside `## Unreleased` blocks and none in a released section.

THE BLOCK'S OWN STATED REASON FOR THE VERSION CHOICE WAS WRONG AND THE SECTION SAYS SO. It said the number depended on whether 0.9.0's image had been built and pulled, and that if it had not, this work belonged inside 0.9.0. That was written before 0.9.0's section was cut. It has been cut since 86bdf49 with 28 runtime commits behind it, so reusing 0.9.0 would make one version string name two different trees - and the Supervisor keys the built image on exactly that string, which is the PKG-06/07 no-op in its worst form.

Evidence: 29/29 green. predeploy_check.py --deployed-version 0.7.0 --options <live blob> clears at exit 0 both before and after, unchanged but for the shipped version line. No default was touched, so test_defaults_pin, test_price's mirror and test_version_gate stay green for the right reason. Eight mutations, no survivors, one at zero bytes. One was a SURVIVOR on the first draft - the slicer control was a sentinel only an EOF-running slicer could reach, so deleting a heading never got there; it asserts an invariant now, exactly one contents table per section.

Card numbers that did not reproduce, corrected in the report: the block is 1541 lines citing 31 ids rather than 5487 citing ~70 (those figures fit the whole file and the Detail notes block, which is PKG-08's subject); 28 runtime commits rather than 30; 18 tickets rather than fifteen. FCST-04 has a table row but no section body - pre-existing, left alone.
2026-09-16 02:58:28 +02:00
adminandClaude Opus 5 cb3f686555 PKG-14: cut 0.10.0, and say what an upgrade from 0.7.0 crosses
checks / unit (pull_request) Successful in 7m51s
`config.yaml` 0.9.0 -> 0.10.0, and the top `## Unreleased` block is closed
into `## 0.10.0` with a preamble that names the backward-incompatible
changes and who they reach.

MINOR, and NOT because eighteen tickets landed. A stored options blob the
previous version started on is REFUSED on this one:

  * TARIFF-07 retires three `price_provider` ids; a site set to one is
    refused BY NAME at startup. Measured on the reference blob, with a
    control on an accepted id so the refusals are about the ID.
  * TARIFF-18 moves `price_taxes_eur_kwh` 0.06 -> 0.11736. A site that
    STORED 0.06 is untouched, and - the non-obvious half - a taxes period
    table beside that stored 0.06 does NOT become a startup refusal on
    upgrade, because `SUPERSEDED_TAXES_DEFAULTS_EUR_KWH` reads it as
    untouched. Measured, with the counterfactual that the rung is not
    weakened (ORES's 0.1198 is still refused).
  * SAFETY-10 adds `shadow_mode`, shipped `auto`. An existing CONTROLLING
    install does not change by one watt and a FRESH one comes up observing.
    Measured cross-revision, 8f82dd4 -> e6da478, same stimulus through the
    shipped `Controller.cycle()`: byte-identical write streams, 13/13/25
    writes. Positive control: the same driver at `shadow_mode: on` gets 13
    writes to 5000 W on the older tree and one 0 W write on the newer.

And the one a reader of the newest section alone would miss: `ha addons
update` does not walk the versions, so a 0.7.0 install meets 0.8.0's and
0.9.0's rules at the same moment as 0.10.0's. Of those, SAFETY-39's rule 10
refuses 0.7.0's OWN shipped default `slew_w: 1000` against a 555.6 W
ceiling on a 5000 W rail. Measured red on this tree; the reference
install's `slew_w: 400` is measured green.

SCOPE, and it is drawn honestly rather than tidily. The top block's 18
entries all merged after the 0.9.0 bump `86bdf49`, so the block is closed
as-is and its `_this branch_` placeholders are resolved to merge shas.
⚠️ 0.10.0 SHIPS THREE MORE RUNTIME TICKETS THAT ARE NOT IN THAT TABLE -
SAFETY-43, TEST-21 and SAFETY-44 - and they are NAMED in the preamble
rather than moved, because re-filing this file's misplaced entries is
PKG-08. SAFETY-44 (`app/main.py`, `app/store.py`) is in the changelog
nowhere at all; that is said in both places. The second `## Unreleased`
block below `## 0.9.0` is ANNOTATED, not rewritten or emptied - UX-02 in it
shipped in 0.9.0, the other three in 0.10.0. No released section is
rewritten.

`test_version_gate.py` gains part 11: the bump and the closed section are
one act. PKG-09 refuses a deploy whose version did not move; nothing graded
the mirror failure, in which the version moves and the block is never
closed. Two sides from two files, a slicer with a synthetic positive
control run on every invocation, the retired ids read off `app/price.py` by
AST rather than transcribed, and the count of still-misfiled blocks frozen
so it can only shrink.

Mutations, all purged, tree bind-mounted :ro, backups at mktemp paths and
the revert fingerprinted:

  M1  `## 0.10.0` -> `## Unreleased`       +4 B    RED 2
  M2  version 0.10.0 -> 0.10.1             +0 B    RED 1   (ZERO-BYTE)
  M3  an id stripped from the NEWEST       +10 B   RED 1
      section only, left below
  M4  a 4th retired provider in price.py   +62 B   RED 1 here, 4 in
                                                   test_price.py
  M5  `## 0.9.0` heading lost              -3 B    RED 1
  M6  a 2nd `## Unreleased` left standing  +27 B   RED 1
  M7  the slicer never closes              -32 B   RED 3
  M8  SUPERSEDED_TAXES... emptied          -5 B    RED 2 on the evidence
                                                   instrument, plus
                                                   test_validate/test_price

⚠️ M5 WAS A SURVIVOR ON THE FIRST DRAFT. The slicer control was a sentinel
(`## 0.8.0`) that only a slicer running to EOF could reach, and deleting one
heading never gets there - ARCH-02's fifteenth instance, in a fresh costume.
11a now asserts the invariant instead: exactly one contents table per
section, which is what a lost heading breaks.

29/29 test files green. `tools/predeploy_check.py --deployed-version 0.7.0
--options <live blob>` CLEARED, exit 0, before and after.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-16 02:48:27 +02:00
admin 587495e143 Merge pull request 'SAFETY-47: say what a shadow run can and cannot show' (#90) from SAFETY-47 into release/1.0
DOCS.md, app/shadow.py's header and DECISIONS/SAFETY-10 all claimed the strategies ask for a fixed power from inputs that do not depend on what the battery did, so a shadow run shows you the real trades. That was true when shadow mode was designed and false by the time it merged: SAFETY-45 landed hours earlier and made the buy leg min(asked, headroom), where headroom = (900/remaining) x (ceiling - projected) and `projected` reads the open quarter's accumulator - the meter, which is exactly a function of what the battery did. The strategy became closed-loop and the exemption went stale.

Measured at a binding cap, 1500/1200/2000, the same hour twice: live grid 1224-1506 W held at the ceiling against a flat 1200 W in shadow; SoC 50.000019 -> 51.856789 % against 50.000000 -> 50.000000; the two runs differ on 716 of 720 cycles; the final recorded figure is -302.4 W live against -2000.0 W in shadow, 6.61x. On a SAFETY-45-reverted tree the limit cycle is 28 onsets live against 1, guard engaged 410/720 against 0/720. Two of the three defects the card cites as motivation are closed-loop phenomena shadow cannot exhibit; TARIFF-14's half genuinely is visible, hour and price and spread identical 720/720.

THE CAVEAT'S DIRECTION WAS MEASURED RATHER THAN WRITTEN, and the ticket had it wrong. A draft saying a live run reaches a SMALLER number was checked pairwise over 3600 charging cycles in five configurations: the shadow record is never below live - zero cycles below and 730 EXACTLY EQUAL, at the start of each quarter where the amplification is 1.0. `Smaller` would have been false on 730 rows. The shipped sentence says UPPER BOUND and the two-point arithmetic behind it is graded.

Caveated rather than re-computed, with the rejections recorded: re-computing would make the recorded decision no longer the decision the shipped path reached while arbiter, clamp, the SAFETY-28 gate, the log and MQTT all ran on the real one - a second controller everywhere except the wire; recording nothing blanks the row exactly when arbitrage trades, and the log's edge key IS the watts; recording the unsized ask beside it adds a second number with no warning, and at the shipped 3500/2000 both read 2000 W. The trap avoided: keying the caveat on `capped` would fire at the quarter's START, where the record is right, and go SILENT at the end, where it is 6.61x out. It keys on the headroom having been MEASURED.

AND THE TICKET'S OWN ANALYSIS WAS INCOMPLETE. I said the committed evidence table could not fail for two reasons. They are independent in the FIX direction too: widening the fixture to a binding cap still leaves the comparison passing, because it reads index zero and the first charging cycle is -300.0000 W in both runs. Fixing only the fixture closes nothing. Recorded in MUTATION.md as a new habit-4 shape - an INDEX, not a fixture - and the agreement at index zero is now graded as an expectation so nobody rebuilds on it.

Evidence: 29/29 green. Fourteen mutations, no survivors. One was a REAL survivor first - deleting the caveat from the action log left all 29 files green, because the sentence was an f-string in _shadow_settle() and the only suite that drives it runs with meter_source: off; it is shadow.log_line() now. One CORRECTLY survived and is reported as such: min -> max makes the record larger, which is still an upper bound, so it is not the inversion that matters. And the new section nearly shipped FCST-06's shape - a mutation made it raise on its first min() and report zero reds - so every check now carries the section's precondition.

Two design limits stated rather than smoothed: the caveat discloses but does not help, since an engineer still cannot obtain the real number without arming the battery - the fix for that is a rig mode replaying the site's own captured meter through the shipped decision path, filed separately and deliberately NOT by giving shadow mode a plant model, which is the one change that would break its safety argument. And SAFETY-10's takeaway still oversells `auto`, which this card did not rewrite.
2026-09-15 01:36:41 +02:00
glenn schrooyenandClaude Opus 5 e3ccd9f6ea SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.

SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.

THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:

  SAFETY-45's limit cycle  NOT visible. 28 onsets live vs 1; grid
                           -455.5..+3200.0 W vs flat at the 1200 W house;
                           guard engaged 410/720 cycles vs 0/720.
  SAFETY-46's SoC churn    NOT visible. The SoC moves 0.000000000 pp.
  TARIFF-14's wrong hour   VISIBLE, and it is the only one: which hour, at
                           what price, clearing what spread - identical on
                           720 of 720 charging cycles at a binding cap.

The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.

THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).

"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.

AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.

SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.

THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.

AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.

14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-15 01:26:57 +02:00
admin e6da478f87 Merge pull request 'SAFETY-10: shadow mode, and 0 W is a number rather than a silence' (#89) from SAFETY-10 into release/1.0
The closed-loop rig made the case for this: with arbitrage armed and a binding cap the loop ran 28 charge onsets an hour (SAFETY-45); the price lookup returned the wrong quarter-hour for 45 minutes in every 60 (TARIFF-14); the SoC ceiling churns 598 Wh to gain 310 (SAFETY-46). Every one was invisible from outside, and there was no way to watch what the optimiser WOULD do without letting it do it.

THE TICKET SAID DEFAULT-ON AND THE AGENT REFUSED IT, correctly. The Supervisor resolves options as {**config.yaml defaults, **stored user options}, so a NEW key with a new default reaches every EXISTING install on the next update - including the one regulating the author's battery. `shadow_mode: true` would have stopped it silently, and the only symptom would be a battery that stopped doing anything. There is no mechanism by which one key defaults differently for a new install and an existing one - `options:` IS the default and there is one of it.

So the default is a value the add-on RESOLVES: shadow_mode: list(auto|on|off), shipped `auto` = shadow while control is STOPPED, live once STARTED. A fresh install ships auto_start: false, so it comes up in shadow and observes before it ever commands - default-on delivered where it is safe. An existing install that is controlling does not change by one watt; verified before merge, `auto` resolves to `not control_started`.

SECOND PUSHBACK, ALSO RIGHT: commands nothing is a NUMBER, not a silence. The inverter holds its last command forever, so a shadow mode that stopped writing would leave whatever was standing STANDING, under a page saying nothing is commanded - the exact looks-healthy-but-is-inert failure this repo keeps finding - and would hold the ESP32's 30 s stale-input watchdog tripped for the whole run, an alarm used as a mode. The actuator is held at 0.0 W, refreshed on the ordinary heartbeat, by the ordinary single writer, as a substitution inside the existing single choke point. Not a second write path. It is the LAST substitution, below SAFETY-28's gate and SAFETY-03's clamp, so both still grade the number the decision produced.

Every failsafe's behaviour is decided and recorded rather than inherited. The sign watchdogs are INERT because they grade standing_w(), held at 0 W - feeding them the decision would have them disagree with a meter that never saw it and LATCH A TRIP SURVIVING INTO LIVE OPERATION AND A RESTART. Clamp, write gate, meter freeze and peak guard OBSERVE the real decision. Circulation and delivery may legitimately latch, because their evidence is measured power. The operator stop is enforced at the wire rather than as a P_SAFETY claim, which would make every recorded decision read `stopped`. A standing latch is named in the shadow banner and turns it red.

Graded on the writes and the rendered surface, never on the flag, with the precondition asserted first: the same stimulus at `off` produces 30 non-zero writes with a largest of 5000 W; at `on`, set(writes) == {0.0} and 26 of them. Closed loop over the same hour twice: live -2000 W throughout, SoC 50.000 -> 62.331 %, grid to 2350 W; shadow 0 W throughout, SoC 50.0 -> 50.0 exactly, grid = the house exactly - with the arbitrage decision identical in action, instant, signed power, reason verbatim and arbiter winner across 3600/3600 samples.

Evidence: 29/29 green, CI green. Twenty-two mutations, no survivors, including a write escaping, silence instead of 0 W, observers blinded, default-on-for-everyone, the stop claim refiled, and a re-seed moved one line earlier which blinds SAFETY-18. Two mutation findings recorded: one first read as a survivor and was not, because a TypeError killed the section and reported zero reds - FCST-06's shape; and one had to become a PAIR because two fields both hold the detector at 0 W - TEST-16's shape.

Recorded limitation rather than glossed: the re-seed makes the exit safe by construction, and the price is that the loop leg's shadow decision is one slew step rather than a trajectory. Graded by name. The strategies are unaffected, which is why all three motivating defects remain visible.
2026-09-14 17:44:26 +02:00
Claude 8fa4febfef SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside
while it was happening, and each was paid for at the meter first: SAFETY-45's
28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong
quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain
310 Wh. There was no way to watch what the optimiser WOULD do without letting
it do it.

`shadow_mode` runs strategies, arbiter, clamps and guards, records the
decision with its reason, and commands nothing.

⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary
single writer. The inverter holds its last command forever - it has no meter
timeout - so "commands nothing" implemented as "stops writing" would leave
whatever was standing when shadow mode came on standing for as long as it was
left on, under a page saying nothing is being commanded. That is the failure
this repository keeps finding. Refreshing 0 W is also what
firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going
quiet would keep that board tripped for the whole run, which is an alarm being
used as a mode.

⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its
own. It is a substitution inside Controller._write_unit() - the single choke
point every write already reaches - in the same form as the three above it,
and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still
grade the number the decision path produced.

⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The
Supervisor composes options as {**config.yaml defaults, **stored user
options}, so a new key with a new default reaches EVERY EXISTING INSTALL on
the next update - including the one regulating a real battery. A boolean
default-on would have stopped it silently. There is no mechanism by which one
key can default differently for a new install and an existing one, so
"default-on for new" is a value the add-on RESOLVES: `auto` is shadow while
control is STOPPED and live once it is STARTED. A fresh install ships
`auto_start: false` and comes up observing; an install that is controlling is
started and does not change by one watt.

THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade
Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision
they would disagree with a meter that never saw it and LATCH A TRIP THAT
SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate
(SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation
(SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch,
because their evidence is measured power. The operator stop is the one
deliberate change: enforced at the wire rather than as a P_SAFETY claim, which
would otherwise make every recorded decision read "stopped".

⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what
stands on the wire, which makes the exit safe by construction - and therefore
the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow
run answers "what would it command now", not "what would it have done next".
The strategies are unaffected; all three defects above are visible from one.

Graded on the writes and on the rendered surface, never on the flag: 22
mutations, no survivors, including one that lets a write escape and one that
goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig,
same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %;
shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage
decision is identical in action, instant, signed power, reason and arbiter
winner.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 17:25:43 +02:00
admin 8f82dd4e06 Merge pull request 'SAFETY-45: size the trade to the headroom instead of interlocking against it' (#88) from SAFETY-45 into release/1.0
With arbitrage armed and a binding peak_cap_w, the loop did not settle: 28 charge onsets an hour, period 131 s, grid swinging -455 to +3200 W, and a billed quarter 59 W OVER the cap it had just spent fifteen minutes holding. Section 10.2 is explicit that an EMS which oscillates is worse than no EMS, for hardware wear and for the peak it is trying to avoid. Not reachable by any unit test in the repo - it needed the closed loop.

THE TICKET'S MECHANISM WAS WRONG AND THE AGENT DISPROVED IT. I wrote that the quarter boundary drives the cycle. Of the 27 gaps between the 28 onsets, 23 are 90-120 s entirely INSIDE one quarter; the four long gaps are exactly the four that SPAN a boundary, so the boundary lengthens the interval rather than causing it. A fix aimed at boundary handling would have removed 4 of 28.

The real cycle is a binary interlock keyed on a continuous quantity: the trade charges at max_w while `wanted = batt_w + excess` is still negative and the guard files nothing; `wanted` crosses zero; the guard engages on a FIVE WATT floor; that flips guard_state(), which cancels the WHOLE trade; the grid-following loop - which targets grid = 0, not grid = ceiling - takes the actuator, discharges to +1870 W and exports 420 W; the projection collapses; the trade re-arms at max_w.

So the fix sizes the buy leg rather than interlocking it. control.maintenance_charge_floor() already caps MAINTENANCE charging at the headroom under the site's cap, because a maintenance charge was the only thing big enough and long enough to set the peak - and that stopped being true when OPT-04 landed. peakguard.charge_headroom_w() publishes the same quantity off the MEASURED guard rather than the optional forecast entity, arbitrage.decide() takes it keyword-only and sizes the buy, main.py passes it. It is wanted_w read in the other direction: no new arithmetic and no new constant.

THE GUARD'S DECISION FUNCTION IS UNTOUCHED, and that is the proof 2026-08-20's bang-bang did not come back. peakguard.py is +139/-0 - zero deleted lines - and sha256(decide) is identical on both trees at 7252 bytes; replay_ac3.py reproduces 190/190 records, 110 engaged, 878 Wh identically. Verified independently before merge. Reverting that rung is red on eight named checks.

Rejected and recorded: a negative `lo`, because it creates a lo > hi contradiction against main.py's cheap-window maintenance shaping that resolves to 0 W - the battery parked in the billed quarter - and closing that would mean suspending maintenance shaping permanently on every affected site. And a backoff timer in arbitrage, because both modules' notes forbid inventing timers; the trade now re-arms at `ceiling - load`, which IS learning from the refusal.

After, on the same rig and the same command: onsets 28 -> 1, grid swing 3655 -> 282 W, and the billed quarters land at exactly 1500.0 W three times over. At the shipped defaults the two affected rows buy ~2% less energy and the worst quarter goes from 59 W over the cap to zero - which is section 10.1's ordering, since the tariff bills the month's single worst quarter. On an aggressive cap the sized trade buys 58% MORE. The non-binding control row is bit-identical.

Evidence: 29/29 green, CI green. Fourteen mutations, all red, two of them zero-byte. The regression closes the loop over the shipped guard, strategy, arbiter, control law and the real QuarterAverager, and asserts BOTH directions from one changed argument plus an inert-where-inert control.

TWO DEFECTS FOUND BY THE DISCIPLINE RATHER THAN BY REVIEW. The agent's own harness restored two edits to one file in list order and left one on disk - caught by the post-revert fingerprint, habit 18 biting a tool written the same afternoon. And test_peakguard.py part 1 formatted floor_w with a bare :.0f one line after the check that reverting the 2026-08-20 rung turns red, so the file ABORTED and parts 2-13 went ungraded: that mutation's coverage was one check and is now eight.
2026-09-14 16:20:39 +02:00
glenn schrooyenandClaude Opus 5 e1b9254626 SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
checks / unit (pull_request) Successful in 7m42s
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff
guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage
3's closed rig against 478ba93, metrics recomputed rather than taken from the
card: `peak_cap_w` 1500 / 1200 W house -> 28 charge onsets an hour, mean period
131.1 s, the grid swinging -455.5 to +3200.0 W; at the SHIPPED
`peak_cap_w: 3500` with an 1800 W house -> 8/h, with a 3000 W house -> 32/h.
The bite rule is `load + max_w > peak_cap_w`, i.e. any house over 1500 W in the
cheapest quarter. §10.2: "an EMS that oscillates is worse than no EMS, both for
hardware wear and - per §9.1 - for the peak it is trying to avoid." And it was
losing the argument it was having: EVERY billed quarter in the three affected
configurations finished OVER the cap.

⚠️ THE CARD'S STATED MECHANISM IS WRONG AND THE CORRECTION IS ON THE RECORD.
The card, and .cache/s45.md before it, say the loop is the quarter boundary
resetting the projection and arbitrage re-arming at full power. It is not. Of
the 27 gaps between the 28 onsets, 23 are 90-120 s (mean 111.5 s) and lie
ENTIRELY INSIDE one quarter; the four long gaps - 230, 240, 250, 255 s - are
exactly the four that SPAN a boundary, so the boundary LENGTHENS the interval
rather than causing an onset. The real cycle, off the recorded fields: the trade
charges at max_w while `wanted = batt_w + excess` is negative and the guard
files NOTHING; `wanted` crosses zero; the guard engages on a floor of 5.3 W;
that flips `arbitrage.guard_state()`, which cancels the WHOLE trade; the
grid-following loop - which targets grid = 0, not grid = ceiling - takes the
actuator and discharges to +1870 W, exporting 420 W; the projection collapses;
the guard releases; the trade re-arms at max_w. A binary interlock keyed on a
continuous quantity. A fix aimed at the boundary would have removed four of
twenty-eight onsets.

THE FIX IS A SHAPE THIS ADD-ON ALREADY HAD. `control.maintenance_charge_floor()`
caps a MAINTENANCE charge at "the headroom left under the site's cap", because
"a maintenance charge is the only thing this system does that is big enough and
long enough to set that peak". ⚠️ That sentence stopped being true when OPT-04
landed. `peakguard.charge_headroom_w()` publishes the same quantity off the
MEASURED guard rather than off the optional `peak_forecast_entity` - the hole
SAFETY-25 had to close in `shaping_suspended()` - and `arbitrage.decide()` sizes
its BUY leg to it, keyword-only and with no default.

NO NEW ARITHMETIC AND NO NEW CONSTANT. The number is `wanted_w` read in the
other direction: `decide()` already computes the DISCHARGE that lands the
quarter on the ceiling, and a negative one is a permitted CHARGE of `-wanted`.
⚠️ `peakguard.decide()` IS UNCHANGED - sha256(decide) = 200090d0835a3a55, 7252 B
on this branch and on 478ba93 - so 2026-08-20's anti-bang-bang rung is exactly
where it was, and tools/replay_ac3.py reproduces 190/190 guarded quarters, 110
engaged cycles, 5 blind and 878 Wh on both trees.

TWO PROPERTIES MAKE IT SAFE TO HAND A STRATEGY, BOTH SWEPT RATHER THAN ARGUED.
It is INVARIANT IN THE BATTERY - raise the charge by dW, the meter rises by dW,
so `excess` rises by dW while `batt_w` falls by dW and `wanted` does not move:
1350.0 W at every point across batt_w -5000..+2000 W on one banked quarter,
while the `excess` those runs see takes six distinct values. It is feed-forward,
so consuming it adds no feedback path around the plant. And HOLDING IMPLIES ZERO
OR UNKNOWN: across 1080 swept combinations not one ENGAGED decision answers a
positive headroom.

AFTER, same rig, same command. 1500/1200: 28 onsets -> 1, grid swing 3655.5 ->
282.0 W, energy bought 180.0 -> 285.2 Wh (+58%, because a continuous 300 W trade
beats a 2000 W trade cancelled for 57% of the hour), billed quarters
1490/1497/1509 -> 1500.0/1500.0/1500.0. 3500/1800: 8 -> 1, 3511/3536/3559 ->
3500/3500/3500. 3500/3000: 32 -> 1, 3519/3542/3557 -> 3500/3500/3500. The two
shipped-default rows buy 2.2% and 1.6% LESS energy and in exchange the worst
quarter goes from 59 W over the cap to zero - which is the ordering §10.1 asks
for, since the capacity tariff bills the month's single worst quarter.
⚠️ AND THE NEGATIVE CONTROL: at peak_cap_w 5000 with a 1200 W house, where
`load + max_w` never reaches the cap, the two runs are BIT-IDENTICAL.

⚠️ A NEGATIVE `lo` WAS CONSIDERED AND REJECTED, AND THE REASON IS IN THE CODE.
Deleting `decide()`'s `wanted <= 0` gate and filing `lo = wanted` is the tidier
answer arithmetically. It creates a new `lo > hi` CONTRADICTION against
main.py's cheap-window maintenance shaping, which files a NEGATIVE `hi`;
arbiter.py clause 2 has no notion of one limit out-ranking another, so it
resolves to 0 W - the battery PARKED in the quarter that sets the bill - and the
only way to close that suspends the maintenance charge shaping PERMANENTLY on
every site this card is about. A backoff or cooldown in arbitrage was rejected
too: both modules' design notes say no timer is invented, and the trade now
re-arms at `ceiling - load` rather than at max_w, which is what learning from a
refusal means when the refusal is a measurement.

THE REGRESSION IS THE LOOP SETTLING, NOT A UNIT TEST ON decide().
test_arbitrage.py 3c closes the loop over the shipped guard, strategy, arbiter,
control law and QuarterAverager with a modelled plant, and asserts BOTH
directions: unsized it must run away (24 onsets, -414..+3200 W, a quarter over
the cap) and sized it must settle (1 onset, 303 W swing, three quarters at
exactly 1500.0 W). The two runs differ in one argument. A third pair asserts the
card is INERT where the defect is inert.

Evidence: 29/29 green. 14 mutations, every one RED on a named check, no
survivors; two are ZERO BYTES - `min()` -> `max()` on the sizing, and the
sized-trade sentence's two operands transposed - and both are red. M13 reverts
the 2026-08-20 rung and is red on EIGHT named checks in test_peakguard and three
in test_arbitrage. Every revert verified by a tree fingerprint AFTER the revert,
which is how a defect in the battery's own harness was found: two edits to one
file, restored in list order, left the first one on disk (MUTATION.md habit 18).
test_peakguard.py part 1 also gained a None-safe format, because the mutation it
exists to catch made it raise TypeError one line later and ABORT the file -
parts 2-13 were ungraded and M13's recorded coverage was one check instead of
eight.

Not fixed, and named: TEST-23 finding 1's export overshoot at the END of a trade
(356-938 W, ~0.37 x max_w) is a different card; a house whose load ALONE exceeds
the cap still has the trade refused outright and the loop drive to grid = 0
rather than to the ceiling, and no swept pair reaches that regime; the container
leg (hadrive.py) was not re-run because test23s3-addon is deliberately stopped
as a second writer on the setpoint entity.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 16:10:34 +02:00
admin 478ba93710 Merge pull request 'TARIFF-16: the injection leg gets its own coefficients' (#87) from TARIFF-16 into release/1.0
export_price_eur_kwh() modelled injection as one scalar. Eneco publishes 0,1 x BELPEX-H - 1,188 on the same card as its consumption formula, identical on the January and September 2026 cards; ENGIE publishes (B x eSpot_15) - A; Aspiravi uses 0,07 against ~0,10 on its own consumption leg. Reproduced against the shipped readers over one real BELPEX day: the published formula gives 24 distinct prices with a spread of 0.16710 EUR/kWh, the scalar gives 0.00000, and 5 of 24 hours are NEGATIVE - down to -0.03008 EUR/kWh - which are the midday hours a PV household exports in. The 6% VAT asymmetry is not wrong in the scalar, it is unstateable.

THE CARD'S BEFORE-STATE WAS WRONG AND THE AGENT CORRECTED IT. I wrote that this affects what the operator is shown. It did not: export_price_eur_kwh() had ZERO callers under app/ - not arbitrage, not the status page, not MQTT. Verified independently before merge; the only references are its own definition, the defaults entry, FRAMEWORK_KEYS and two comments. So the honest before-state is weaker than the card claimed: the scalar was not a misleading display, it was an UNREAD OPTION. DOCS, CHANGELOG and the startup line say so, and a check grades it. An operator actually seeing their injection price is a separate ticket.

Machinery reused rather than copied, which is TARIFF-17's move applied a second time: parse_export_formula() is parse_price_formula() with ONE argument moved, selecting a row of a _LEGS table, so everything that differs between the legs is a string and the units table, NaN rule, closed enumerations, unknown-key refusal, card comparison and DST handling are one implementation. Pinned by a check that parses every file under app/ and asserts all 32 grammar names are defined in exactly one module, plus an AST pin on the wrapper's body, plus twelve refusal sentences DERIVED from the consumption leg's own.

A NEGATIVE INJECTION PRICE IS ACCEPTED AND AN IMPLAUSIBLE ONE IS STILL REFUSED, and the bound had to move to achieve it: implausible_all_in() floors consumption at +0.02 EUR/kWh of energy, which is fatal on a leg that is legitimately negative. The bound is now off the PRICE and onto the COEFFICIENTS, where it is index-free and sign-free - a pass-through band (0.10-10x; Eneco 1.00x, Aspiravi 0.70x) and an offset-magnitude bound (0.20 against published 0.01188 and 0.02). One spec is put through both bands and the answers printed: the consumption band refuses -0.03008, the injection band accepts it.

The missing printed estimate is stated, not worked around. Eneco's injection line has no worked example beside it, so `card` is optional on this leg and unchanged on the other; where an estimate exists the self-check runs at the same tolerance, and where it does not validate.py logs that the coefficients are UNGRADED and names the two bounds that ran instead. A check MEASURES the resulting gap: a factor of 0.070 where the contract says 0.100 - 30% of every export payment - passes both bounds, because 0.70x is a pass-through somebody really publishes.

The scalar path is genuinely unchanged: the function body is pinned on the AST and seven option dicts are compared against the pre-TARIFF-16 expression with ==.

Evidence: 29/29 green, CI green. Twenty mutations, every one red on a named check. Giving the injection band TARIFF-15's floor is red in test_price.py and GREEN IN THE OTHER 28 FILES; so are the second-grammar and ignore-the-formula mutants. One is a single byte, one is ZERO bytes and moves no decision - legs transposed in the VAT banner, caught by an ordered-pair check. One is recorded for its SHAPE rather than its result: rerouting the scalar through the seam recurses, so the suite dies naming nothing, and a second mutation of the same property exists so a check can name it.

Two sharp edges flagged rather than smoothed: `index` and `resolution` on the injection leg name a series nobody fetches, which an operator could misread as a promise to fetch it; and the coefficient bands are materially weaker than a card check, catching the factor-of-10 class and nothing else.
2026-09-13 18:51:25 +02:00
glenn schrooyenandClaude Opus 5 995da777ce TARIFF-16: the injection leg stops being one number
checks / unit (pull_request) Successful in 7m42s
`price.py` modelled what a site is PAID for export as ONE scalar. The market
publishes a line, and the cards say so in their own words: Eneco Zon & Wind
Dynamisch `0,1 x BELPEX-H - 1,188` c EUR/kWh - "het injectietarief is dynamisch
en kan per uur wijzigen", identical on the January and the September 2026 cards;
ENGIE Dynamic `(B x eSpot_15) - A`; Aspiravi `0,07 x Belpex - 2`.
`price_export_formula` carries that line with its OWN coefficients.

⚠️ THIS IS NOT A WRONG-TRADE FIX, AND SAYING SO IS PART OF SHIPPING IT.
`arbitrage.py` does not read `export_price_eur_kwh` at all - its own comment
says so, citing §9.3's near-zero Belgian injection price as the reason the
economically sound trade on this market is charge-cheap-to-displace-expensive-
IMPORT. Both hours it compares are all-in CONSUMPTION prices. No trade this
add-on takes today is decided by an injection price and nothing here changes
one. What it changes is what an operator is told, and what a future
export-aware strategy rests on: OPT-06 and any export logic would otherwise
inherit a scalar that cannot represent the market, and the 6% VAT asymmetry
would be invisible in the arithmetic. test_price.py 17h parses every module
under app/ and goes red the day something calls an injection reader, so that
sentence is graded rather than attested.

FOUR PROPERTIES A SCALAR CANNOT HOLD. Its own factor (Eneco 0,102 consumption
against 0,100 injection; Aspiravi 0,07 against ~0,10 - not the consumption B
with a sign flip). A negative offset, which `price_markup_eur_kwh: float(0,1)`
cannot express at all. VAT-exemption - "injectietarieven zijn vrijgesteld van
btw" - against 6% on consumption, representable only because `vat_pct` is PER
SPEC. And a price that goes below zero with no floor, under 11,88 EUR/MWh of
BELPEX-H, which is the middle of a sunny day.

⚠️ A NEGATIVE INJECTION PRICE IS ACCEPTED, AND THAT NEEDED A DIFFERENT BAND
RATHER THAN A LOWER FLOOR. `implausible_all_in()` floors the consumption leg at
+0.02 EUR/kWh of energy; applied to injection that refuses the real market in
the hours it matters most. Measured rather than argued: 17c puts ONE spec
through BOTH bands and prints that the consumption band refuses -0.03008
EUR/kWh while the injection band accepts it. The floor was not decoration - it
is what catches a card read a hundred times too small, the one unit error the
card self-check cannot see because it cancels out of a comparison between the
two sides - so the bound moves OFF the price and ONTO the coefficients, where
it is index-free and sign-free: a pass-through band (Eneco's injection leg is
1.00x, Aspiravi's 0.70x; the band is 0.10-10x) and an offset magnitude bound
(0.20 EUR/kWh against published 0.01188 and 0.02). Two rungs that can both
answer a hundredfold error, so each is graded on its REASON, each gets a
stimulus the other cannot reach with the precondition asserted as its own
check, and they are mutated TOGETHER (TEST-16).

⚠️ THE CARD SELF-CHECK APPLIES WHERE THERE IS A CARD, AND WHERE THERE IS NOT
THAT IS STATED RATHER THAN WORKED AROUND. `price_formula` can require a `card`
block because a Belgian card prints the consumption formula, the reference
index AND the resulting price. Eneco's INJECTION formula is printed with no
price beside it. Requiring a block would make the published line inexpressible;
inventing the estimate would grade the coefficients against arithmetic done
with the same coefficients. So the block is OPTIONAL on this leg and unchanged
on the other, the self-check runs at the same tolerance wherever a printed
estimate exists, and validate.py says at startup - "its coefficients are
UNGRADED" - when it does not, naming the two bounds that ran instead. This is
TARIFF-15 demonstrating two tariffs end to end rather than three, one card
later. 17e also MEASURES the size of that gap: a factor of 0.070 where the
contract says 0.100 - 30% of every export payment - passes both bounds, because
0.70x is a pass-through somebody really publishes.

ONE PARSER, NOT TWO. `parse_export_formula()` is `parse_price_formula()` with
its OPTION NAME as an argument - TARIFF-17's move on `parse_static_profile()`,
exactly - and everything that differs between the legs is a string in one
`_LEGS` table. A second copy would be a second unit table, a second NaN rule, a
second unknown-key rule and a second `to_resolution()`, diverging first on the
23- and 25-hour days. test_price.py 17b pins it two ways: all 32 grammar names
are defined in exactly ONE module under app/, with the scope COMPUTED by
parsing every file rather than listed; and twelve refusal sentences for the new
option are DERIVED from the old option's own sentence rather than transcribed.
The four sentences that deliberately differ are named, with what differs, and
asserted to differ.

NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships "";
`export_price_eur_kwh()`'s body is byte-identical, pinned on the AST rather
than on the source text; `export_price_at()` falls through to it for every
index value. 17f compares seven option dicts x five index values against the
pre-TARIFF-16 expression with `==`.

`price_export_formula` joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is derived
from that set, and `code_leaks()` refuses a plugin that names it with nothing
else edited.

ALSO CORRECTED HERE: config.yaml's comment beside `export_price_eur_kwh` still
read "no shipped supplier publishes a dynamic injection curve". TARIFF-07
struck that claim from app/price.py and DOCS.md and did not reach config.yaml,
where it has been shipping since.

20 mutations, every one red on a named check, ledger in test_price.py below
section 17 - including a ZERO-byte one (the two legs transposed in the
VAT-asymmetry banner: no decision moves, only the sentence) and a ONE-byte one
(`card_required=True` on the injection leg). Three run over all 29 files and
red on test_price.py alone. 29/29 green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 18:41:06 +02:00
admin 4dcd9b0fc6 Merge pull request 'TARIFF-18: the taxes default is half the real Flemish figure' (#86) from TARIFF-18 into release/1.0
price_taxes_eur_kwh shipped at 0.06 against a real Flemish 0.11736 - Fluvius Antwerpen 5,35 + bijzondere accijns 4,876 + groene stroom/WKK 1,51 + energiebijdrage 0, incl. 6% VAT, from the Eneco residential card for September 2026. Across the eight Fluvius DSOs the range is 0.117-0.131, so the shipped default was roughly half. The components ship as rows in the code, and the exact unrounded sum is used so the check asserts an EQUALITY against them rather than a tolerance. The energiebijdrage is a ZERO ROW, not an absence - it went to 0 EUR/MWh on 2026-08-01 and was merged into the excise, so anyone hand-computing this from an older guide double-counts it; deleting the row changes no sum, so its PRESENCE is graded separately.

AN UPGRADE HAZARD THE TICKET DID NOT NAME, found and closed. App.options is a deepmerge of config.yaml's defaults over the stored options, so the moment the default moves, every site STORING 0.06 becomes non-default with nobody having edited anything. Combined with TARIFF-17's new rung - a taxes period table beside a non-default scalar is a startup refusal - a working Walloon or Brussels site with a table would have hit SystemExit(78) on the upgrade, over an inert number the table overrides anyway. Closed with SUPERSEDED_TAXES_DEFAULTS_EUR_KWH: validate.py reads a superseded default as untouched too. The rung is NOT weakened - a genuinely custom 0.1198 beside a table is still refused by name, and the refusal now names both figures.

AND THE TICKET'S FRAMING WAS WRONG. I wrote that a site which took the default silently gets a different number. That is not what the deepmerge does: an existing install keeps its stored 0.06 and sees nothing change. The new default reaches a FRESH install, and an existing one only when its options are re-saved. Said plainly in the CHANGELOG, flagged as not re-measured on this branch (the 70-of-71-keys figure is 0.9.0's), with predeploy_check.py --options named as what would confirm it.

THE FIGURE IS THE BOTTOM OF THE BAND, DELIBERATELY, and the argument is the agent's rather than the ticket's: the error directions are not symmetric. Set too high, a genuinely negative hour reads positive and the add-on exports into paid disposal - section 17's own regression case. Set too low, it only declines a trade that would have paid. One default standing in for eight DSOs belongs at the bottom, and Antwerpen's 0.11736 is a real card row there rather than a synthesised minimum.

A CHECK HAD TO BE REWRITTEN RATHER THAN RE-POINTED. test_price.py section 0 justified its own constants by '0.06 is exactly twice 0.03'. This card ends that coincidence, so the sentence is false and is gone; it now asserts per figure that neither shipped default equals the fixture, which is stronger than the tuple compare it replaced. Recorded rather than quietly dropped, along with three other now-false claims the change created in test_price.py's docstring, MUTATION.md and DECISIONS/TARIFF-15 - which had predicted this card and is annotated as shipped.

Evidence: baseline 29/29 before any edit, 29/29 on the committed tree. Ten mutations, all red, every revert sha256-verified and every grade taken in a container with the tree :ro so no .pyc can exist. Two are zero-byte. The interesting one moves the component rows AND the default AND config.yaml together into a coherent West-Vlaanderen card - caught only by the literal typed in the test file and the band check, which is why the sum is graded from two independent sides. What the suite cannot see is stated in the PR: it grades the default against the card as a number, never the card against Belgium.
2026-09-13 16:33:37 +02:00
glenn schrooyenandClaude Opus 5 9c65ac2cf8 TARIFF-18: price_taxes_eur_kwh stops shipping at half the real figure
checks / unit (pull_request) Successful in 7m48s
`price_taxes_eur_kwh` shipped at 0.06 EUR/kWh with no recorded provenance -
no card, no date, no component list - and roughly HALF the true Flemish
all-in non-energy figure. It now ships at 0.11736, and the rows it is made
of are in the code rather than in this message:

  Fluvius distribution (Antwerpen)              5,35   c EUR/kWh
  Bijzondere accijns, "Alle verbruik"           4,876
  Bijdrage groene stroom en WKK Vlaanderen      1,51
  Energiebijdrage (0 EUR/MWh since 2026-08-01)  0
                                               ------
                                               11,736 c EUR/kWh = 0.11736

Eneco residential card for Flanders, September 2026, incl. 6 % VAT.
`app/price.py`'s FLEMISH_TAXES_COMPONENTS_EUR_KWH carries the rows and
test_price.py section 1b re-adds them - and also compares the total against
the card's own figures typed in the test file, so an edit that moved the
rows and the default together is still caught.

WHAT THIS IS NOT. It is not an arbitrage-correctness fix and it cannot be.
This scalar is a LEVEL component: an additive constant cancels exactly in
`max - min` and leaves the argmin where it was. TARIFF-17 shipped that proof
and it is unchanged - test_price.py 16b drives six flat scalars spanning and
exceeding the whole per-DSO range and gets the identical cheapest hour and
the identical spread to the last digit. DOCS and the CHANGELOG say so in
those words.

WHAT IT IS. A display and guard fix:

  * every number an operator reads, which at half the true value made the
    add-on look considerably better than it is; and
  * §17's negative-price guard in arbitrage.py - the one rung that tests an
    ABSOLUTE all-in price rather than a difference. It fires when
    `spot < -(markup + taxes)`, so its boundary moves -0.09 -> -0.14736
    EUR/kWh of spot. test_arbitrage.py section 2c drives both sides through
    the shipped decide() and pins the boundary from below as well.

The default is Antwerpen's real row, near the LOW end of the 0.117-0.131
per-DSO band, and that is deliberate: the error directions are not
symmetric. Too high carries a genuinely negative hour above zero and the
add-on exports into paid-for disposal - §17's own case. Too low only
declines a discharge that would have paid.

TARIFF-17's INTERACTION, WHICH HAD TO BE DECIDED. Nothing in that rung
hardcoded 0.06; it read PRICE_OPTION_DEFAULTS, so moving the default moves
what it refuses. The Supervisor sets `App.options = deepmerge(config.yaml
defaults, stored options)`, so a saved blob carries the key whether it was
typed or not - every stored 0.06 became "non-default" with nobody editing
anything, and a working Walloon or Brussels site with a taxes table would
have met SystemExit(78) on the upgrade over an inert number. price.py now
carries SUPERSEDED_TAXES_DEFAULTS_EUR_KWH = (0.06,) and validate.py reads a
superseded default as untouched too. The rung is NOT weakened: 0.1198 beside
a table is still refused by name, and the refusal now names both figures.

config.yaml and PRICE_OPTION_DEFAULTS moved together; CFG-03's tripwire
(test_price.py section 1, test_defaults_pin.py) stayed green by agreeing.
test_price.py section 0's fourth check was REWRITTEN rather than re-pointed:
it used to justify the file's own grading constants by observing that the
shipped pair was degenerate (0.06 is exactly twice 0.03). TARIFF-18 ends
that coincidence, so the sentence is no longer true and is not kept.

29/29 test files green. Mutation ledger on the PR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 16:24:56 +02:00
admin 7796f168a9 Merge pull request 'TARIFF-17: a charge that varies by hour gets somewhere to live' (#85) from TARIFF-17 into release/1.0
price.py modelled taxes as one flat scalar. In Flanders that is correct - Fluvius distribution is a single rate - but the Walloon DSOs publish day/night bands on the same card: ORES 13,27 vs 7,39, AIESH 15,17 vs 8,21, ORES IMPACT 16,578 vs 5,090 c EUR/kWh. The bands are ANTI-CORRELATED with what the battery wants to do - cheap network hours coincide with cheap spot hours - so flattening them systematically UNDERSTATES the spread and declines cycles that are genuinely profitable.

The flat scalar was never a wrong number. It sits in the additive bucket and provably cannot change which hour is cheapest; the defect was that a component belonging in the order-changing bucket had nowhere to live. That framing is the ticket, and it is what the regression grades.

Reproduced on one ordinary Belgian winter Thursday, same feed, same markup, taxes the only argument differing: five flat scalars spanning AND exceeding the table's own range - 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000 - all give cheapest hour 13 and spread 0.1500 to the last digit, while the ORES table gives hour 03 and 0.1788. Asserted through the shipped decision, static_tariff.arbitrage().cheapest, not through assemble()'s output. Before this existed the shipped tree answered assemble(..., <table>) -> TypeError.

The fixture differs in exactly ONE way and that is its own precondition - same caps object, same RawPoint list, same markup, by identity - and the flat arm is a FAMILY rather than a single scalar, so what the comparison measures cannot be a level effect. That closes the shape that produced a whole-suite survivor in TARIFF-11, where a fixture varied two things at once.

GRAMMAR REUSED, NOT DUPLICATED. parse_taxes_profile() is parse_static_profile() with option= and means= as default arguments, so every pre-existing call site and sentence is byte-identical. Graded two ways: one check parses every module under app/ and asserts the 14 grammar names are defined in exactly one of them, with an AST pin that the wrapper's whole body is one call; another DERIVES all thirteen refusal sentences for the new option from the old option's own sentence. Copying the tiling check into price.py is red.

A WHOLE CARD TYPED IN CENTS IS ITS OWN RUNG, and not a restatement of the parser's plausibility bound. ORES's 13,27 trips that bound - but SIBELGA'S ENTIRE BRUSSELS CARD (9,39 / 7,10) IS UNDER IT and would have started as a 9.39 EUR/kWh levy. Graded by its own reason, and the mutation is red on the Sibelga line only.

Malformed tables are refused at STARTUP by validate.py across three rungs. If one ever gets past, load_prices() returns a section 11.4 no-data read naming the key and logs an error - no silent fall back to the scalar, no traceback into the tick.

Both plugins that need the framework to add taxes move 13 -> 03 (custom_formula {ENERGY,MARKUP} and generic_dayahead {ENERGY}); manual_csv, which is all-in, stays at 13. Enumerated from PROVIDERS rather than typed.

Evidence: 29/29 green. Thirteen mutations, all red, and no row is an edit-and-revert - each gets a fresh rsync'd copy with no __pycache__, mounted :ro, then deleted, which closes habit 18 structurally rather than by discipline. Hoisting the lookup out of assemble()'s loop (+17 B) keeps the number right while stopping it varying by hour: red on six named checks in test_price.py and GREEN IN THE OTHER 28 FILES.

Three things named rather than rounded off: one mutant is equivalent and unseparable by any fixture, because StaticProfile.at() calls brussels() on whatever instant it is given; DOCS' bucket table is prose that nothing asserts, though the numbers it quotes are printed by the checks on every run; and the card's own 0.2240/0.2422 figures were NOT verified and were not repeated - replaced with a claim that is derivable from the contract price, that the spread is proportional to factor and the offset drops out.

One design point is explicitly the owner's, not the agent's: a table beside a NON-DEFAULT price_taxes_eur_kwh is a refusal, so an operator adopting the table must set that key back to 0.06. The alternative - warn, table wins - is the silent-loser shape this repo refuses everywhere else, so the refusal was taken and flagged rather than quietly chosen.
2026-09-13 15:40:17 +02:00
glenn schrooyenandClaude Opus 5 2fac0aaf06 TARIFF-17: a price component that varies by hour has somewhere to live
checks / unit (pull_request) Successful in 7m25s
`price.py` modelled the whole non-energy part of a Belgian bill as ONE flat
scalar. This adds `price_taxes_profile`, which carries the TAXES component as
a period table, and makes `assemble()` evaluate it at each point's own instant.

⚠️ THE FLAT SCALAR WAS NOT A WRONG NUMBER, AND THIS IS NOT A CORRECTION OF ONE.
The optimiser reads exactly two quantities off a series - the spread
`max - min` over the firm points, and which hour is cheapest - and an additive
constant identical in every hour cancels out of the first and leaves the second
where it was. It is provably inert. Measured, and printed by test_price.py 16b
on every run: with a flat taxes figure of 0.00, 0.0739, 0.1198, 0.1327 or 1.00
EUR/kWh the same 24-hour feed is cheapest at 13:00 in all five cases and its
spread is 0.1500 EUR/kWh in all five cases. What was missing is anywhere for an
HOUR-VARYING non-energy component to live. This is a missing capability, not a
bad constant.

Belgium has one. Fluvius distribution is a single rate - its tariff-card row
reads `Normaal | Uitsl. nacht`, where exclusive night is a separate physical
circuit and not a night register - so nothing changes for the reference site in
Flanders. The Walloon DSOs and Sibelga are on the same card with four columns,
`Enkelvoudig | Dag | Nacht | Uitsl. nacht`, and the gap is real money (c/kWh):
ORES 13,27 / 7,39; AIESH 15,17 / 8,21; Tecteo RESA 12,20 / 7,01; Sibelga
9,39 / 7,10; ORES IMPACT 2026 16,578 / 5,090.

⚠️ AND THE BANDS ARE ANTI-CORRELATED WITH WHAT THE BATTERY WANTS TO DO. The
cheap network hours are the cheap spot hours, so flattening them does not shift
the curve - it UNDERSTATES the spread and declines cycles that would have paid.
Same feed, same markup, the only difference being the taxes argument:

    flat 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000
                                       -> cheapest hour 13, spread 0.1500
    ORES dag 0.1327 / nacht 0.0739     -> cheapest hour 03, spread 0.1788

The regression check grades WHICH HOUR IS CHEAPEST, not the spread: an
implementation that reads the table once and adds one number to every point is
the LEVEL bucket wearing a period table - right magnitude, wrong shape - and a
spread assertion passes on it. Measured: hoisting the lookup out of
`assemble()`'s loop (+17 B) is red on six named checks in test_price.py and
GREEN in the other 28 files.

ONE GRAMMAR, NOT TWO. `static_tariff.py` already shipped the periods, the day
selectors, the tiling rule and the DST handling, so `parse_taxes_profile()` is
the same parser with the option name and the "what this number means" clause as
arguments. A second tiling rule would be a second set of 23- and 25-hour-day
bugs. test_static_tariff.py section 10 pins that two ways: by parsing every
module under `app/` and asserting the grammar is defined in exactly one of
them, and by deriving each of thirteen refusal sentences for the new option
from the old option's own sentence rather than transcribing them.

`Component.TAXES` semantics, `code_leaks()` and the double-counting guarantee
are untouched. The new key joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is
derived from that set, and a plugin that names it is refused at `register()`.
It reaches both plugins that take taxes - `custom_formula` ({ENERGY, MARKUP})
and `generic_dayahead` ({ENERGY}) - and not `manual_csv`, which is all-in: the
table is routed through `capabilities().adds`, exactly as the scalar is.

⚠️ A MALFORMED TABLE IS REFUSED AT STARTUP, NOT AT THE NEXT FETCH. It is read
on the ~30 s planning path, and a table that first fails at 03:00 is a site
that stops pricing at 03:00, which §11.4 turns into a quiet fallback
indistinguishable from a healthy fixed-tariff day. validate.py refuses three
things: a table that does not tile the day; a table set beside a NON-DEFAULT
`price_taxes_eur_kwh`, because the table wins and the scalar would then be a
number the operator typed that decides nothing; and a whole card typed in
CENTS, which is how these figures are printed. That last rung is not a
restatement of the parser's +-10 EUR/kWh bound - ORES's 13,27 trips the parser,
but Sibelga's entire card, 9,39 and 7,10, is under it and would otherwise have
started as a 9.39 EUR/kWh levy. Both rungs are graded by the REASON each gives,
and mutating them together (TEST-16) moves three rows.

NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships "", and the
scalar path is unchanged arithmetically rather than merely in intent:
test_price.py 16f reproduces the pre-TARIFF-17 expression and compares 12
capability/scalar combinations point for point with `==`.

13 mutations, every one red on a named check, ledger in test_price.py below
section 16k with byte deltas and the one equivalent mutant named. 29/29 green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 15:31:15 +02:00