price.py modelled taxes as one flat scalar. In Flanders that is correct - Fluvius distribution is a single rate - but the Walloon DSOs publish day/night bands on the same card: ORES 13,27 vs 7,39, AIESH 15,17 vs 8,21, ORES IMPACT 16,578 vs 5,090 c EUR/kWh. The bands are ANTI-CORRELATED with what the battery wants to do - cheap network hours coincide with cheap spot hours - so flattening them systematically UNDERSTATES the spread and declines cycles that are genuinely profitable.
The flat scalar was never a wrong number. It sits in the additive bucket and provably cannot change which hour is cheapest; the defect was that a component belonging in the order-changing bucket had nowhere to live. That framing is the ticket, and it is what the regression grades.
Reproduced on one ordinary Belgian winter Thursday, same feed, same markup, taxes the only argument differing: five flat scalars spanning AND exceeding the table's own range - 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000 - all give cheapest hour 13 and spread 0.1500 to the last digit, while the ORES table gives hour 03 and 0.1788. Asserted through the shipped decision, static_tariff.arbitrage().cheapest, not through assemble()'s output. Before this existed the shipped tree answered assemble(..., <table>) -> TypeError.
The fixture differs in exactly ONE way and that is its own precondition - same caps object, same RawPoint list, same markup, by identity - and the flat arm is a FAMILY rather than a single scalar, so what the comparison measures cannot be a level effect. That closes the shape that produced a whole-suite survivor in TARIFF-11, where a fixture varied two things at once.
GRAMMAR REUSED, NOT DUPLICATED. parse_taxes_profile() is parse_static_profile() with option= and means= as default arguments, so every pre-existing call site and sentence is byte-identical. Graded two ways: one check parses every module under app/ and asserts the 14 grammar names are defined in exactly one of them, with an AST pin that the wrapper's whole body is one call; another DERIVES all thirteen refusal sentences for the new option from the old option's own sentence. Copying the tiling check into price.py is red.
A WHOLE CARD TYPED IN CENTS IS ITS OWN RUNG, and not a restatement of the parser's plausibility bound. ORES's 13,27 trips that bound - but SIBELGA'S ENTIRE BRUSSELS CARD (9,39 / 7,10) IS UNDER IT and would have started as a 9.39 EUR/kWh levy. Graded by its own reason, and the mutation is red on the Sibelga line only.
Malformed tables are refused at STARTUP by validate.py across three rungs. If one ever gets past, load_prices() returns a section 11.4 no-data read naming the key and logs an error - no silent fall back to the scalar, no traceback into the tick.
Both plugins that need the framework to add taxes move 13 -> 03 (custom_formula {ENERGY,MARKUP} and generic_dayahead {ENERGY}); manual_csv, which is all-in, stays at 13. Enumerated from PROVIDERS rather than typed.
Evidence: 29/29 green. Thirteen mutations, all red, and no row is an edit-and-revert - each gets a fresh rsync'd copy with no __pycache__, mounted :ro, then deleted, which closes habit 18 structurally rather than by discipline. Hoisting the lookup out of assemble()'s loop (+17 B) keeps the number right while stopping it varying by hour: red on six named checks in test_price.py and GREEN IN THE OTHER 28 FILES.
Three things named rather than rounded off: one mutant is equivalent and unseparable by any fixture, because StaticProfile.at() calls brussels() on whatever instant it is given; DOCS' bucket table is prose that nothing asserts, though the numbers it quotes are printed by the checks on every run; and the card's own 0.2240/0.2422 figures were NOT verified and were not repeated - replaced with a claim that is derivable from the contract price, that the spread is proportional to factor and the offset drops out.
One design point is explicitly the owner's, not the agent's: a table beside a NON-DEFAULT price_taxes_eur_kwh is a refusal, so an operator adopting the table must set that key back to 0.06. The alternative - warn, table wins - is the silent-loser shape this repo refuses everywhere else, so the refusal was taken and flagged rather than quietly chosen.
GoodWe RS485 Controller — Home Assistant add-on repository
Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.
repository.yaml add-on repository metadata
goodwe_controller/ the add-on
config.yaml manifest + options schema (the per-site config form)
app/ the controller
control.py the control law — pure functions, no I/O
maintenance.py the monthly cycle state machine
hass.py Supervisor/Core API access
store.py persistent state in /data
mqtt.py optional status entities
web.py ingress UI — routes only, status and configuration
config_page.py the configuration page's markup, style and script
configui.py its field model, built from the Supervisor's own
schema + translations — owns no key, label or rule
selfconfig.py reading and writing this add-on's own options,
with the validate-first / compare-and-swap gate
main.py orchestration, heartbeat, failsafe behaviour
test_control.py runnable checks — no framework needed
test_maintenance.py runnable checks — walks a full cycle in fake time
DOCS.md the add-on's documentation tab
MUTATION.md how to run a mutation so the result means something
tools/mutation_run.sh the mutation harness - purges bytecode, then grades
tools/supervisor_selfapi_probe.py what the Supervisor really permits and
returns, run against its own release image
firmware/goodwe-master.yaml ESPHome config for the T-CAN485
estop/rs485_log.py optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf the guide techs carry (10pp, A4)
docs/build_guide.py its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md how to edit and rebuild the guide
Picking this up after a break? Read HANDOVER.md first — current state,
what is known broken, and what to do next.
Install
Settings → Add-ons → Add-on store → ⋮ → Repositories → add
https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon
then install GoodWe RS485 Controller.
⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it
anonymously; against a private repo the store shows nothing and gives no useful
error. If it must stay private, install locally instead: copy
goodwe_controller/ into the machine's /addons/ folder, then
ha store reload — it appears as a Local add-on.
⚠️ Bump version: in goodwe_controller/config.yaml for every change.
Supervisor keys the built image by that version, so without a bump it silently
reuses the old image and your fix appears not to work — on your bench and on
every client's machine.
Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.
Read this first
The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.
Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:
- ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
- Wind-down before firmware updates — 0 W written before the update starts.
- RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.
Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md
§10 signed.
Development
The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:
cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py
Both must pass before shipping any change. To prove a check bites - the way
almost every claim in this repository was established - mutate the module and
run tools/mutation_run.sh, which clears __pycache__ first. It is not
optional: a same-size edit reverted inside one second leaves CPython reusing the
old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md
has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre —
each assertion corresponds to a rule whose absence produced an observed failure
on real hardware, and the comments in control.py say which.
Compatibility
Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:
| tag | platform | verdict |
|---|---|---|
ESU EMU ESA BPS BPU EMJ IJL |
105 — ES/EM/BP, AA55-era meter bus | supported |
SPB SPN |
745 — SBP G2 (GW…-SBP-20) |
no |
ESN ESC |
745 — ES G2 (GW…-ES-20) |
no |
ETU EHU BTU … |
205/745/753 — ET/EH/BT hybrids | no |
SDT DST MSU NSU … |
PV-only inverters — no battery to control | no |
A "-20" or "G2" suffix means a different platform with a different meter
protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which
is also what Home Assistant's own integration uses to pick a protocol.
- GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
- The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.