Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
ffb8ec6373 | ||
|
|
878a6ce452 | ||
|
|
bb64f8fdd7 | ||
|
|
e40eb0768d | ||
|
|
cc4e88490b | ||
|
|
2513ba1f12 | ||
|
|
9aed43990b | ||
|
|
35856a73ae | ||
|
|
aae74d7571 | ||
|
|
8cc9438aec | ||
|
|
96a808a057 | ||
|
|
88cd97cc7a | ||
|
|
e2e331ea54 |
+32
-1
@@ -52,9 +52,40 @@ Run the checks before deploying. No framework needed:
|
||||
|
||||
```bash
|
||||
cd goodwe_controller
|
||||
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py
|
||||
python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.py \
|
||||
&& python3 test_validate.py && python3 test_p1.py && python3 test_watchdog.py \
|
||||
&& python3 test_loop.py
|
||||
```
|
||||
|
||||
`test_watchdog.py` covers SAFETY-02's logic, its arming gate (derived from the
|
||||
real arbiter, not passed in), its trip path, and the fact that the latch survives
|
||||
an add-on restart. Its headline validation is not here at all: `sim/replay_sign.py`
|
||||
in the infra repo drives the same module over the two captured RS485 days and must
|
||||
fire on all four of the 2026-08-20 episodes and stay silent on 2026-08-23. That
|
||||
needs both checkouts:
|
||||
|
||||
```bash
|
||||
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py
|
||||
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py --stub
|
||||
```
|
||||
|
||||
The second run checks the grader still *discriminates* rather than merely still
|
||||
passing — a watchdog that never trips and one that always trips must both be
|
||||
rejected.
|
||||
|
||||
⚠️ **If you are testing the failsafe by hand, note that stopping and starting the
|
||||
add-on will not clear a trip.** That is the point of it; use the *Start / stop
|
||||
control* button twice, or delete `sign_tripped` from `/data/state.json`.
|
||||
|
||||
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
|
||||
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
|
||||
wall-clock property about it (SAFETY-12); mocking the clock there would leave the
|
||||
assertion testing the mock. The other six suites together are ~440 checks and finish in
|
||||
seconds — `test_watchdog.py` spends ~3 s of that driving a real `Controller` through a
|
||||
trip. If you shorten `test_loop.py`'s windows, re-measure and correct this figure —
|
||||
an understated runtime is what makes a slow test look like a hung one, and a slow test
|
||||
that looks hung gets deleted.
|
||||
|
||||
---
|
||||
|
||||
## 3. Known broken / unfinished
|
||||
|
||||
@@ -1,5 +1,203 @@
|
||||
# Changelog
|
||||
|
||||
## Unreleased
|
||||
|
||||
**Cheap-window maintenance charging was unreachable at the shipped defaults, and
|
||||
now the config that makes it unreachable is refused (MAINT-04).** `config.yaml`
|
||||
shipped `max_w: 2000` against `maintenance_charge_w: 2500`. The cheap-window
|
||||
shaping files `Claim.limit(hi = -maintenance_charge_w)` against the supervised
|
||||
SAFETY limit's `lo = -max_w`, so `lo > hi` — the arbiter's clause 3, correctly
|
||||
resolved to **0 W** and logged as a CONTRADICTION. **Maintenance silently never
|
||||
charged in a cheap window on a default install**, and the only evidence read
|
||||
like a bug in the arbiter rather than like the two numbers an operator set.
|
||||
Measured against the real arbiter, loop asking +500 W:
|
||||
|
||||
```
|
||||
max_w=2000 hi=-2500 -> +0 W contradiction=True
|
||||
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
|
||||
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(cheap-window charge)
|
||||
```
|
||||
|
||||
`validate_startup_config()` now refuses `maintenance_charge_w > max_w` (rule 6),
|
||||
the same shape as CFG-01's `sign_disagree_w >= max_w`: a number the operator set,
|
||||
overridden by a layer they cannot see. Equality is reachable (`-max_w` is a
|
||||
single valid point) and deliberately not refused. Verified by starting the
|
||||
add-on on the pre-fix pair: exit 78, the refusal banner, no traceback.
|
||||
|
||||
**`maintenance_discharge_w` was checked, not assumed, and it is NOT the same
|
||||
case.** The shaping is not symmetric. The drain phase does not shape the loop,
|
||||
it OWNS the actuator — `Claim.set(P_MAINTENANCE, +discharge_w)` — and a SET is
|
||||
*clamped* by the limits above it rather than contradicted by them. 2500 against
|
||||
a 2000 W ceiling emits **+2000 W**, and the arbiter's own `explain()` prints
|
||||
`maintenance -> 2000 W, limited by supervised(max_w)` every cycle. Nothing is
|
||||
silent and energy still moves; the cycle completes slower (13.8 kWh usable at
|
||||
2000 W is ~6.9 h against the 720 min drain timeout). **Warned about, not
|
||||
refused.**
|
||||
|
||||
**The shipped defaults changed so the validator does not reject them.**
|
||||
`maintenance_charge_w` and `maintenance_discharge_w` are now **2000**, at the
|
||||
shipped `max_w`. `max_w` was deliberately NOT raised instead: it is the
|
||||
supervised safety ceiling and raising a default upward ships more power to every
|
||||
new install. Raising `max_w` (the reference install runs 5000) is what unlocks a
|
||||
faster maintenance cycle — raise it first, then these. `test_validate.py` now
|
||||
reads `config.yaml` itself and asserts the shipped numbers pass the rule, so a
|
||||
default that the validator refuses cannot ship again.
|
||||
|
||||
### ⚠️ Upgrading an existing default install: the add-on may refuse to start
|
||||
|
||||
An install still carrying `maintenance_charge_w: 2500` against `max_w: 2000`
|
||||
now meets rule 6 and **exits 78 with the refusal banner** instead of starting.
|
||||
That is the intended behaviour — the configuration was already broken, it was
|
||||
just silent about it — but an add-on that will not come back after an update
|
||||
needs the fix stated here rather than only in the log.
|
||||
|
||||
**The fix, either way: set `maintenance_charge_w` to `2000` or lower, OR raise
|
||||
`max_w` to `2500` or higher** (Settings → Add-ons → GoodWe RS485 Controller →
|
||||
Configuration), then start it. The banner in the log says the same thing and
|
||||
names both numbers.
|
||||
|
||||
Whether you hit this at all depends on whether the Supervisor kept the old
|
||||
value, and **both cases are covered above because we did not verify which one
|
||||
applies here.** The Supervisor merges an add-on's *stored* options over the
|
||||
defaults in `config.yaml`, so:
|
||||
|
||||
- **A key the operator never edited** re-derives from the new `config.yaml` and
|
||||
becomes 2000 on upgrade. Non-event, nothing to do.
|
||||
- **A key the operator did set** persists at 2500 and the add-on refuses to
|
||||
start until it is changed. Note this includes anyone who used the
|
||||
Configuration page's YAML editor, which writes the whole options block back —
|
||||
so "I never touched that field" is not a guarantee the old value is gone.
|
||||
|
||||
⚠️ **This is reasoned from the Supervisor's documented merge behaviour, not
|
||||
measured on the live install.** The reference install's stored options could not
|
||||
be read (`/api/hassio/` refuses a long-lived token) and probing it was out of
|
||||
scope — it regulates a real battery. It runs `max_w: 5000` and is unaffected
|
||||
either way.
|
||||
|
||||
⚠️ **Known, deliberately left, and worth a follow-up:** `main.py` and
|
||||
`maintenance.py` still fall back to **2500** when the key is absent from the
|
||||
options dict, while `config.yaml` and `validate.py` now say 2000. Unreachable on
|
||||
a Supervisor install (every key is always supplied) and reachable only from
|
||||
tests/`sim`. The real fix is one source of truth for option defaults, which is
|
||||
bigger than this ticket and touches files another ticket is in.
|
||||
|
||||
## 0.5.1
|
||||
|
||||
**SAFETY-02's latch now survives an add-on restart, which is the difference
|
||||
between a latch and a pause.** `auto` was persisted and `sign_wd.tripped` was
|
||||
not, so reconstructing the `Controller` against the same store — exactly what a
|
||||
container restart does — brought it back **armed, into the same fault, with no
|
||||
operator involved**: `tripped=False`, banner back to `NOT READY`, and it resumed
|
||||
commanding (measured: −1000 W, −2000 W) before re-tripping 180 s later. Under a
|
||||
Supervisor that restarts a crashed add-on that is a loop of three-minute
|
||||
wrong-direction bursts — and "restart the add-on" is the first thing an operator
|
||||
looking at a `FAILSAFE` banner and a 0 W inverter will try.
|
||||
|
||||
`sign_tripped` and `sign_reason` are now `Store` keys beside the maintenance
|
||||
state, written the moment the trip happens (reason first, flag second, so a crash
|
||||
between the two can never persist a latch with no explanation) and restored in
|
||||
`Controller.__init__`. Cleared only by the operator's start. `DOCS.md` said "it
|
||||
does not clear itself"; that was false across a restart and now is not.
|
||||
|
||||
Also in this release, all of it review follow-up rather than new behaviour:
|
||||
|
||||
- **The arming gate is tested against the real arbiter.** It was the decision the
|
||||
whole ticket turns on and it was asserted in three comment blocks and verified
|
||||
by nothing — every case passed `following` in as a literal. `test_watchdog.py`
|
||||
now derives it from `resolve()` across twelve claim configurations, including
|
||||
the redirect case `winner == "loop"` alone would have got wrong and the `lo`
|
||||
limit that raises magnitude without flipping sign.
|
||||
- **The MQTT `status: "failsafe"` value is tested.** The check that claimed to
|
||||
cover it restated the assertion three lines above it and never touched the
|
||||
payload.
|
||||
- **A forward hazard written down where it will be read, and made to bite.**
|
||||
`winner == "loop"` disarms the watchdog under any higher-priority SET claim.
|
||||
Today only maintenance and the safety stops emit one and neither follows the
|
||||
meter; a peak-shaving strategy at `P_PEAK` **does**, and would blind the
|
||||
watchdog for every peak event.
|
||||
|
||||
The gate is now `watchdog.loop_is_following()`, called by both `main.py` and
|
||||
the test, for the same reason `disagrees()` was extracted: the test held a
|
||||
*transcription* of the shipped expression, so editing the shipped gate alone to
|
||||
`winner in ("loop", "peak")` left every suite green while the watchdog went
|
||||
blind. Two copies, and the one that drifts is the one doing the grading.
|
||||
|
||||
⚠️ Extracting it was not sufficient on its own. The realistic P_PEAK row —
|
||||
peak shaving asking for *more* than the loop — still could not detect the
|
||||
widened gate, because the magnitude term rejects it regardless and masks the
|
||||
winner term. A second row with peak asking for *less* isolates `winner` as the
|
||||
only deciding term, and that is the one that turns red.
|
||||
- **The worked example described a configuration that does not ship.** At the
|
||||
defaults `maintenance_charge_w` (2500) exceeds `max_w` (2000), so that claim is
|
||||
an arbiter *contradiction* resolving to 0 W, not a −2500 W charge. The example
|
||||
is now written at 1500 W. (The contradiction is a real pre-existing bug —
|
||||
a default cheap-window maintenance charge silently never happens — filed
|
||||
separately, deliberately not fixed here.)
|
||||
- **`disagrees()` is public**, so `sim/replay_sign.py` stops carrying its own copy
|
||||
of the predicate it grades.
|
||||
- `held_s` takes the clock instead of reading one, restoring the pure-function
|
||||
property the module advertises.
|
||||
- **The `sign_reason`-before-`sign_tripped` write ordering is enforced, not just
|
||||
documented.** Swapping the two lines used to pass every check. A store that
|
||||
fails the second write now proves the property the ordering exists for: what
|
||||
survives a crash mid-trip is a reason with no latch, never a latch with no
|
||||
explanation.
|
||||
- Measured figures corrected throughout: 93.4 % / 4212 of 17280 (was 92.9 % /
|
||||
4127 of 16349), per-cluster 0.3 / 0.9 / 10.5 / 0.0 %.
|
||||
|
||||
## 0.5.0
|
||||
|
||||
**SAFETY-02 — the sign-disagreement watchdog.** The add-on now watches whether
|
||||
the setpoint it is emitting and the grid figure it is regulating on point the
|
||||
same way. If they oppose each other, both over `sign_disagree_w` (300 W), for
|
||||
`sign_disagree_s` (180 s) **continuously**, it files a failsafe claim at
|
||||
`P_SAFETY`, commands **0 W**, and latches there until an operator starts control
|
||||
again. New module `app/watchdog.py`; new options `sign_disagree_w` and
|
||||
`sign_disagree_s`.
|
||||
|
||||
This is the gap the existing failsafes leave open. The stale-input watchdog asks
|
||||
whether the meter is still talking, the saturation freeze asks whether the
|
||||
inverter can follow, the output clamp asks whether the number is too big — a
|
||||
loop can pass all three while charging the battery out of the grid, because the
|
||||
only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly
|
||||
that four times in one day, for up to 77 minutes at a stretch, and reached a
|
||||
commanded −14 768 W against a ±5000 W inverter.
|
||||
|
||||
Validated against that day. `sim/replay_sign.py` in the infra repo drives this
|
||||
module over the committed RS485 captures of both 2026-08-20 (the four episodes)
|
||||
and 2026-08-23 (healthy): **18 trips on the fault day, every one inside a window
|
||||
`NOTES.md` §4.7 accounts for, and 0 on the healthy day.** The four episodes do
|
||||
share one signature rather than merely resembling each other — sign agreement
|
||||
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 93.4 % on the healthy day.
|
||||
|
||||
Three decisions worth knowing about:
|
||||
|
||||
- **It is disarmed whenever the grid-following loop is not what is driving.**
|
||||
Sign agreement is a property of a loop that follows the meter. A maintenance
|
||||
grid charge opposes the meter *by design* — 2500 W of charge into a house
|
||||
drawing 500 W is +3000 W on the meter against a −2500 W command, for hours —
|
||||
and armed unconditionally this would trip on every maintenance cycle. The gate
|
||||
tests the emitted number, not the winning claim's name: a limit claim can let
|
||||
the loop "win" and still replace its value with one pointing the other way.
|
||||
- **The trip latches.** Commanding 0 W removes the command side of the
|
||||
comparison, so the disagreement always clears the moment the trip works.
|
||||
Un-latched, this would trip, clear, and hand the actuator back to the loop that
|
||||
was driving the wrong way, every three minutes forever.
|
||||
- **`sign_disagree_w` at or above `max_w` is refused at startup** (validator rule
|
||||
5). The arbiter never lets a command exceed `max_w`, so such a threshold makes
|
||||
the watchdog incapable of firing while the status page still reports it armed.
|
||||
A disarmed guard that advertises itself as armed is the failure mode this
|
||||
project keeps refusing to ship.
|
||||
|
||||
What it does **not** catch, stated so nobody assumes otherwise: an inverter that
|
||||
acts opposite to what it was told moves the meter *further* the same way, so
|
||||
command and meter agree while everything runs away. That is the saturation
|
||||
freeze's job, which compares the command against the battery's actual power.
|
||||
|
||||
`test_validate.py`'s "the smallest sane max_w still starts" case now names a
|
||||
reachable sign threshold, because a 1 W ceiling genuinely does disarm the 300 W
|
||||
default and is now correctly refused.
|
||||
|
||||
## 0.4.0
|
||||
|
||||
**CFG-01.** The add-on now refuses to start on a configuration it cannot honour,
|
||||
@@ -67,6 +265,121 @@ A refusal is legible as a refusal: a banner that says in words that this is a
|
||||
configuration problem and nothing is broken, the numbered problems, no traceback,
|
||||
and exit status 78 (`EX_CONFIG`).
|
||||
|
||||
**SAFETY-12.** The control loop now evaluates on a clock as well as on a change.
|
||||
`run_control()` ran `cycle()` only when the meter value differed from the
|
||||
previous poll, so a meter that repeated a value ran **no control cycles at
|
||||
all** - while the heartbeat went on re-emitting the last command and the
|
||||
firmware went on putting it on the wire every 2 s. Layer 1 stayed fed, every
|
||||
indicator read healthy, and a command computed from an old reading kept being
|
||||
executed through whatever the load did next. Measured on the rig during TEL-05:
|
||||
70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
|
||||
|
||||
**It was worse than a latency limit: it was a safety claim that could not
|
||||
fire.** `stale_input_s` and the `inputs missing -> 0 W` claim both live *inside*
|
||||
`cycle()`. Pre-fix, if the meter value happened to be constant, `cycle()` was
|
||||
never called again - so that claim had no way to run. Constant meter, SoC entity
|
||||
dying at t=4 s, same binary:
|
||||
|
||||
```
|
||||
pre-fix writes: [(0.0, 220.0), (0.0, 220.0), (10.1, 220.0)]
|
||||
final target: 220.0 W reason: 'loop -> 220 W'
|
||||
post-fix writes: [(0.0, 220.0), (0.0, 220.0), (3.0, 430.0), (9.1, 0.0), (10.1, 0.0)]
|
||||
final target: 0.0 W reason: 'safety -> 0 W'
|
||||
```
|
||||
|
||||
The pre-fix controller held 220 W through the entire input outage with its
|
||||
status line still reading `loop -> 220 W`, and layer 1 does not cover that case
|
||||
on a `meter_source: off` install: no P1 age sensor is published, so the firmware
|
||||
has nothing to veto on, while the heartbeat keeps its watchdog fed. So the old
|
||||
behaviour was not "holds a stale command safely" - it was a failsafe that a
|
||||
repeating meter switched off. `test_loop.py` asserts both halves.
|
||||
|
||||
`cycle_floor_s` (default **15 s**) is a deadline on the gap between cycles, not
|
||||
a second scheduler: every cycle resets it, whichever trigger fired. On a healthy
|
||||
meter it never elapses, so the cycle rate, the write sequence and therefore the
|
||||
per-cycle gain the tuning was measured against are unchanged - asserted in
|
||||
`test_loop.py` by driving the real loop twice on one binary (a huge
|
||||
`cycle_floor_s` reproduces the old behaviour exactly) and comparing the
|
||||
commanded values.
|
||||
|
||||
The reset is not the only thing holding that up, and the other argument is the
|
||||
sturdier one: the combined cycle rate is `max(arrival rate, 1/floor)`, never the
|
||||
sum. At 1/15 s the floor is strictly slower than the ~1/5 s arrival rate, so
|
||||
even a hypothetical floor racing the arrivals could not exceed the nominal
|
||||
healthy rate. The re-tune is unreachable by construction. ⚠️ That holds only
|
||||
while `cycle_floor_s` stays above the meter's update interval, and the schema
|
||||
minimum is 5 s - which is exactly the reference meter's interval. Nothing
|
||||
enforces the relationship; `validate.py` is the obvious home for it and does not
|
||||
have it yet.
|
||||
|
||||
Observed over six real minutes on the same rig, one binary, meter held at a
|
||||
literally constant 350.0 W: **before, 1 cycle** (at startup) and then nothing,
|
||||
the command stuck at 220 W against a 350 W import for the rest of the window.
|
||||
**After, 24 cycles**, worst gap 15.14 s, and the ordinary PI ramp doing its job -
|
||||
220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle,
|
||||
rail at t=136 s and flat after. Three minutes with the meter parked at the
|
||||
target instead: **1 cycle before, 12 after, and 19 writes either way - the same
|
||||
19**. Three minutes on a normally-changing meter: **36 cycles and 49 writes on
|
||||
both sides, the same values in the same order.** The heartbeat write count never
|
||||
moves; the only writes the fix adds are the ten the loop was supposed to be
|
||||
making all along.
|
||||
|
||||
15 s is bracketed, not round.
|
||||
|
||||
**Below it, ~11 s, and it arises more routinely than a dropped poll.**
|
||||
`HomeWizardLocalSource` polls at 5.0 s against a meter that updates every 4.97 s
|
||||
(NOTES.md:640). Two near-equal periods beat, so roughly once every ~14 minutes
|
||||
the poller steps over an update entirely - a ~10 s gap between changed values on
|
||||
a perfectly healthy meter, plus up to 1 s for the 1 s tick to notice. A failed
|
||||
HTTP poll (retried on the next tick, no backoff) adds another 5 s. The floor
|
||||
sits above the beat-skip so it does not fire on that alone; what it takes to
|
||||
reach 15 s is a beat-skip *and* a failed poll coinciding.
|
||||
|
||||
**Above it, 30 s.** `meter_max_age_s` is 30 s, past which there is no reading to
|
||||
evaluate, and the firmware's ingest veto is also 30 s - so the loop is
|
||||
guaranteed to have re-decided at least twice inside any window in which layer 1
|
||||
might otherwise be the only thing deciding. ⚠️ The default is therefore not
|
||||
independently justified at 15: if the firmware's veto ever moves, this moves
|
||||
with it. Noted beside the constant in `main.py`.
|
||||
|
||||
It is also exactly `stale_input_s`, this system's existing answer to "how long
|
||||
may we hold without re-deciding".
|
||||
|
||||
A floor cycle runs the **full** law on the same inputs, integrator included. In
|
||||
P1 mode the freshness question is already answered upstream and answered harder
|
||||
- past `meter_max_age_s` the reading is None, which is "inputs missing", which
|
||||
is a `P_SAFETY` 0 W claim - so a floor cycle there can only ever run on a reading
|
||||
this system already calls fresh. ⚠️ That is transport-conditional: with
|
||||
`meter_source: off`, `read_inputs()` takes the grid figure straight from
|
||||
`hass.number()` with **no age gate at all**, so a Home Assistant entity that has
|
||||
gone quiet reads as current on that path, with or without this change. Running
|
||||
the full law is still right there - the alternative is a degraded second law
|
||||
reasoning about an age nobody measured - but the floor does not make that path
|
||||
fresh. The integrator advances per *cycle*, not per second,
|
||||
so bounding the gap bounds the accumulation; `integrator_max_w` bounds it after
|
||||
that. A gentler second law for floor cycles would be a second set of dynamics
|
||||
nobody can test on this hardware.
|
||||
|
||||
⚠️ **This is not a freeze detector**, and TEL-05 established one cannot be built
|
||||
here: at the converged -10 W target a 1 Wh register needs ~6 minutes to move
|
||||
while the power figure legitimately repeats, so any threshold on `unchanged_s`
|
||||
false-trips at the exact operating point we run at. Nothing in this change
|
||||
decides whether a repeated reading is *true*. It stops "the number is the same"
|
||||
from meaning "do not think". The consequence, stated plainly: against a meter
|
||||
genuinely frozen at a wrong value the loop will now correct toward that wrong
|
||||
value rather than hold a stale command, bounded by `max_w`, the arbiter and the
|
||||
device rating. That was already what happened to a lying meter whose value
|
||||
merely jittered; bit-exact repetition was never a safety property.
|
||||
|
||||
`DOCS.md`'s "Saturation is counted in cycles, not seconds" section documented
|
||||
the old behaviour as an accepted deviation. It is **qualified, not deleted**:
|
||||
the deviation survives (the window is still counted in cycles, and 3 x 15 s is
|
||||
still not the specification's 10 s) but it is now bounded at 45 s instead of
|
||||
open-ended, and the passage's second justification - "nothing accumulates while
|
||||
it is stalled" - is called out as having covered integrator windup and not
|
||||
staleness, which was the actual hazard. The same wrong argument in
|
||||
`control.py`'s saturation comment is corrected too.
|
||||
|
||||
**TEL-04.** `meter_source: ha_signed` reads a single *signed* power entity, which
|
||||
is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two
|
||||
unsigned registers and refuse negatives, so neither fits the meter installed here.
|
||||
|
||||
+98
-16
@@ -24,6 +24,9 @@ The inverter **holds its last command forever** — it has no meter-timeout. So:
|
||||
commanding it.
|
||||
- This add-on commands 0 W when its inputs go missing, when you stop control,
|
||||
and when it shuts down.
|
||||
- This add-on commands 0 W **and latches there** if what it is commanding and
|
||||
what the meter reads point opposite ways for three minutes — see "The
|
||||
sign-disagreement failsafe" below.
|
||||
- The **optional RS485 e-stop** is the only thing that covers this machine
|
||||
dying. Without it, a failed host leaves the battery latched at its last
|
||||
command until someone intervenes.
|
||||
@@ -272,11 +275,69 @@ behind it would trip the firmware watchdog on a system that is working fine.
|
||||
| `target_grid_w` | -10 | What the meter should rest at. Negative = a slight export |
|
||||
| `step_w` | 10 | Quantisation |
|
||||
| `saturation_w` | 500 | Divergence that counts as "the inverter is at a limit" |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one *changed* meter reading, not a fixed period - see the note below. **Do not set to 1** |
|
||||
| `saturation_cycles` | 3 | How many consecutive cycles before freezing. A cycle is one meter update or `cycle_floor_s`, whichever comes first - see the note below. **Do not set to 1** |
|
||||
| `integrator_max_w` | 0 | Bound on the loop's accumulator, and 0 means "same as `max_w`". Caps how much stale error can be waiting to unwind when the sign flips. **Do not raise it above `max_w`** - the output clamp already bounds what is commanded, so the only thing extra headroom buys is more cycles of wrong-direction power after every saturation event. Lowering it below `max_w` is the useful direction |
|
||||
| `heartbeat_s` | 10 | Refresh interval; must stay well under the firmware watchdog |
|
||||
| `cycle_floor_s` | 15 | The longest the loop may go without evaluating. A deadline on the gap between cycles, reset by every cycle — on a healthy meter it never elapses and changes nothing. Raise it only if your meter is slower than ~10 s; it must stay under `meter_max_age_s`, past which there is no reading to evaluate anyway |
|
||||
| `stale_input_s` | 15 | How long inputs may be missing before commanding 0 W. In P1 mode this clock starts only *after* `meter_max_age_s` has already expired — the two stack, see "How long a dead meter takes to reach 0 W" |
|
||||
| `auto_start` | false | Start controlling on boot (only after commissioning) |
|
||||
| `sign_disagree_w` | 300 | Both the command and the meter must exceed this before a sign difference counts. Must stay **below `max_w`** or the watchdog can never fire, and the add-on refuses to start |
|
||||
| `sign_disagree_s` | 180 | How long they must stay opposed, continuously, before the failsafe trips |
|
||||
|
||||
#### The sign-disagreement failsafe
|
||||
|
||||
If the setpoint this add-on is emitting and the grid figure it is regulating on
|
||||
point **opposite ways** — charging the battery while the house imports, or
|
||||
discharging it while the house exports — with both over `sign_disagree_w`, for
|
||||
`sign_disagree_s` **continuously**, the add-on commands **0 W** and holds it
|
||||
there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
|
||||
**It does not clear itself, and restarting the add-on does not clear it either.**
|
||||
Pressing *Start / stop control* twice — stop, then start — is the only thing that
|
||||
does. That is deliberate on both counts:
|
||||
|
||||
- Commanding 0 W removes the command side of the comparison, so the disagreement
|
||||
always vanishes the instant the trip works. A watchdog that took that as proof
|
||||
the fault was over would hand the inverter straight back to the loop that was
|
||||
driving the wrong way, three minutes later, forever.
|
||||
- The trip is written to `/data/state.json` and restored on startup. Restarting
|
||||
the add-on is the first thing most people try when they see a red banner, and
|
||||
a latch that a restart clears would bring the controller back **armed, into the
|
||||
same fault, unattended** — and under a Supervisor that restarts a crashed add-on
|
||||
automatically, would do so in a loop. After a restart the banner, the 0 W and
|
||||
the recorded reason are all still there.
|
||||
|
||||
**What it is for.** This is a loop-integrity check: it asks whether the loop's
|
||||
output direction still matches the input state it was regulating. It catches a
|
||||
polarity error anywhere between the meter and the wire, and an integrator so far
|
||||
wound up that unwinding takes minutes. It is the check that would have caught all
|
||||
four episodes of 2026-08-20, when a commercial controller charged the battery out
|
||||
of the grid, four times, for up to 77 minutes at a time.
|
||||
|
||||
**What it is not for.** It does not detect an inverter that acts opposite to what
|
||||
it was told — that moves the meter *further* the same way, so command and meter
|
||||
agree while everything runs away. That is the saturation freeze's job
|
||||
(`saturation_w` / `saturation_cycles`), which compares the command against the
|
||||
battery's actual power. The two checks are complementary and neither replaces the
|
||||
other.
|
||||
|
||||
**Why it will not false-trip on ordinary operation.** A battery that refuses a
|
||||
command (empty, full, standby) leaves the meter where it was, so command and
|
||||
meter agree. A frozen meter drives the loop into agreeing with it. Around the
|
||||
resting point both signals are inside the 300 W gate, so the deadband can never
|
||||
produce one. A load step does flip the meter's sign before the loop catches up —
|
||||
measured on a full captured day, the longest such crossing is 30 s, against a
|
||||
180 s window. And the watchdog is **disarmed whenever the grid-following loop is
|
||||
not what is driving**: a maintenance grid charge opposes the meter by design and
|
||||
must not be mistaken for a fault.
|
||||
|
||||
Both numbers are measured rather than chosen, and are exposed only because the
|
||||
ticket requires defaults rather than constants. On the captured healthy day sign
|
||||
agreement is 93.4 %; on the four captured fault clusters it is 0.3 %, 0.9 %,
|
||||
10.5 % and 0.0 %. There is no reason to move either value without a capture that
|
||||
says so.
|
||||
|
||||
#### Saturation is counted in cycles, not seconds
|
||||
|
||||
@@ -284,22 +345,43 @@ The specification states the saturation window as **"> 10 s"**. This add-on coun
|
||||
**cycles** instead, and that is a deliberate, accepted deviation rather than an
|
||||
oversight - the acceptance criterion is not met as literally written.
|
||||
|
||||
A cycle here is one *changed* meter reading: the controller only runs the loop when the
|
||||
meter value differs from the previous poll. At the reference P1's ~5 s update rate the
|
||||
default of 3 cycles is usually around 15 s, but there is **no guaranteed wall-clock
|
||||
window** - a meter that repeats the same value stalls the counter for as long as it
|
||||
repeats.
|
||||
A cycle here is one meter update **or `cycle_floor_s` elapsing, whichever comes
|
||||
first**. At the reference P1's ~5 s update rate the default of 3 cycles is usually
|
||||
around 15 s, and the worst case is bounded at `3 x cycle_floor_s` = 45 s. It is still
|
||||
not the 10 s the specification asks for, so the deviation stands - but it is now a
|
||||
bounded number rather than an open one.
|
||||
|
||||
Two reasons that is acceptable:
|
||||
⚠️ **This passage used to say something different, and the second half of it was
|
||||
wrong.** Until SAFETY-12 the loop ran only when the meter value *changed*, so a meter
|
||||
that repeated a value stalled the counter for as long as it repeated, with no upper
|
||||
bound at all. That was defended here on the grounds that "a stalled counter is a
|
||||
detection-latency limit and not a runaway risk - the condition that stalls it stops the
|
||||
whole loop, so nothing accumulates while it is stalled". That argument covers
|
||||
**integrator windup and nothing else**. The hazard it misses is **staleness**: while the
|
||||
loop was stopped the heartbeat kept re-emitting the last command and the firmware kept
|
||||
putting it on the wire every 2 s, so a command computed from an old reading went on
|
||||
being executed through a real load change, with every indicator reading healthy.
|
||||
Measured on the rig during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals,
|
||||
zero control cycles.
|
||||
|
||||
- the control law is a pure function with no clock, which is what makes it testable
|
||||
without hardware, and a seconds-based window would have to live in the controller;
|
||||
- a stalled counter is a detection-latency limit and not a runaway risk. The condition
|
||||
that stalls it - an unchanging meter - stops the whole loop, so nothing accumulates
|
||||
while it is stalled.
|
||||
The half that survives is the first one: the control law is still a pure function with
|
||||
no clock, and the wall-clock window still lives in `Controller`, which has one - see
|
||||
`run_control()`. What changed is that the controller now enforces a floor on the gap
|
||||
between cycles, so `saturation_cycles` finally means a bounded number of seconds.
|
||||
|
||||
If a guaranteed window matters on your site, raise `saturation_cycles` for a fast meter,
|
||||
and treat the figure as "N meter updates" rather than "N seconds".
|
||||
If a tighter window matters on your site, lower `cycle_floor_s` (not below your meter's
|
||||
update interval, or the floor starts firing on a healthy meter) or raise
|
||||
`saturation_cycles` for a fast meter.
|
||||
|
||||
**This is not a freeze detector, and it deliberately cannot be one.** Nothing here
|
||||
decides whether a repeated reading is true — see `unchanged_s` in the meter section for
|
||||
why no threshold on that is safe at the converged operating point. The floor only stops
|
||||
"the number is the same" from meaning "do not think". The consequence is worth stating
|
||||
plainly: against a meter that is genuinely frozen at a wrong value, the loop will now
|
||||
correct toward that wrong value instead of holding a stale command. It is bounded by
|
||||
`max_w`, the arbiter and the device rating, and it is the same thing that already
|
||||
happened to a lying meter whose value merely jittered — bit-exact repetition was never a
|
||||
safety property.
|
||||
|
||||
#### Why `target_grid_w` is not zero
|
||||
|
||||
@@ -332,8 +414,8 @@ help - see "Why the tuning is what it is".
|
||||
| `maintenance_enabled` | false | Enable the monthly cycle |
|
||||
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
|
||||
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
||||
| `maintenance_discharge_w` | 2500 | Drain rate (exports the surplus) |
|
||||
| `maintenance_charge_w` | 2500 | Charge ceiling, capped again by peak headroom |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
||||
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor |
|
||||
| `maintenance_soc_target` | 99 | Charge target |
|
||||
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
|
||||
|
||||
@@ -95,19 +95,23 @@ def compute(
|
||||
# lets slew be larger than saturation_w.
|
||||
#
|
||||
# The spec states this window twice and differently: "> 10 s" (§11.2) and
|
||||
# "3 samples" (§10.3). This counts CYCLES, and a cycle is not a unit of
|
||||
# time: run_control() calls cycle() only when the meter value CHANGES
|
||||
# (`if self.grid != last_grid`), so three cycles is three distinct meter
|
||||
# readings and nothing more. At the reference P1's ~5 s update rate that is
|
||||
# usually ~15 s, but there is no upper bound on it - a meter that repeats a
|
||||
# value stalls the counter.
|
||||
# "3 samples" (§10.3). This counts CYCLES, and a cycle is still not a unit
|
||||
# of time - but it is now a BOUNDED one. run_control() runs a cycle on a
|
||||
# changed meter value OR on `cycle_floor_s` elapsing, whichever comes first
|
||||
# (SAFETY-12), so three cycles is at most 3 x cycle_floor_s = 45 s at the
|
||||
# defaults, and usually ~15 s at the reference P1's ~5 s update rate.
|
||||
#
|
||||
# That is a detection-latency limit, not a windup hazard: the same
|
||||
# condition that stalls the counter stalls the whole loop, so nothing
|
||||
# accumulates in the meantime either. If a wall-clock window is ever
|
||||
# required, it belongs in Controller (which has a clock) and not here.
|
||||
# ponytail: this function is worth keeping clockless; the ceiling is that
|
||||
# saturation_cycles cannot express a guaranteed number of seconds.
|
||||
# ⚠️ THIS COMMENT USED TO CLAIM there was no upper bound and that it did not
|
||||
# matter, "because the same condition that stalls the counter stalls the
|
||||
# whole loop, so nothing accumulates in the meantime". The first clause was
|
||||
# true and the second was the bug: a stalled loop does not stop commanding,
|
||||
# it goes on emitting its last command through the heartbeat. Windup was
|
||||
# never the hazard; staleness was.
|
||||
#
|
||||
# The wall-clock window lives in Controller, which has a clock, exactly as
|
||||
# this comment always said it should. ponytail: this function stays
|
||||
# clockless; the remaining ceiling is that saturation_cycles expresses a
|
||||
# bound in seconds rather than an exact number of them.
|
||||
saturated_now = abs(prev_w - actual_w) > tuning.saturation_w
|
||||
sat_count = min(sat_count + 1, 10) if saturated_now else 0
|
||||
frozen = sat_count >= tuning.saturation_cycles
|
||||
|
||||
@@ -41,6 +41,7 @@ from .maintenance import IDLE, MaintConfig, Maintenance
|
||||
from .mqtt import MqttPublisher
|
||||
from .p1 import P1Ingest, build_source, is_enabled
|
||||
from .validate import ConfigRefused, refuse, validate_startup_config
|
||||
from .watchdog import SignWatchdog, SignWatchdogConfig, loop_is_following
|
||||
from . import web
|
||||
|
||||
OPTIONS_PATH = "/data/options.json"
|
||||
@@ -103,6 +104,29 @@ class Controller:
|
||||
store,
|
||||
)
|
||||
|
||||
# SAFETY-02. One instance, one actuator, one cadence - see watchdog.py.
|
||||
#
|
||||
# ⚠️ RESTORED FROM THE STORE, and that is the difference between a latch
|
||||
# and a pause. A trip held only in memory is cleared by the one action an
|
||||
# operator staring at a FAILSAFE banner is most likely to take - restart
|
||||
# the add-on - and the controller then comes back armed, into the fault,
|
||||
# with nobody involved. Restored here, the banner and the 0 W survive the
|
||||
# restart and only `auto_toggle` clears them.
|
||||
self.sign_wd = SignWatchdog(
|
||||
SignWatchdogConfig(
|
||||
min_w=float(opts.get("sign_disagree_w", 300)),
|
||||
hold_s=float(opts.get("sign_disagree_s", 180)),
|
||||
),
|
||||
tripped=bool(store.data.get("sign_tripped", False)),
|
||||
reason=str(store.data.get("sign_reason", "") or ""),
|
||||
)
|
||||
if self.sign_wd.tripped:
|
||||
_LOG.error("SAFETY-02 was TRIPPED before this restart and stays "
|
||||
"tripped: %s. The inverter is held at 0 W. Restarting the "
|
||||
"add-on does not clear this - start control from the UI "
|
||||
"once you know why the command opposed the meter.",
|
||||
self.sign_wd.reason or "(reason not recorded)")
|
||||
|
||||
# P1 ingestion (TEL-01). `meter_source: off` keeps the original
|
||||
# single-entity meter_entity path, so an existing install is unchanged
|
||||
# until it opts in.
|
||||
@@ -120,6 +144,11 @@ class Controller:
|
||||
self.sat_count = 0
|
||||
self.i_w = 0.0 # the loop's integrator, carried between cycles
|
||||
self.loop_w = None # what the loop asked for last cycle, or None
|
||||
# Did the grid-following loop actually win the LAST arbitration? That is
|
||||
# the question SAFETY-02 has to ask about the command standing on the
|
||||
# wire right now, so it is recorded when the arbitration happens rather
|
||||
# than re-derived a cycle later. Starts False: nothing is on the wire.
|
||||
self.following = False
|
||||
self.reason = "starting"
|
||||
self.grid = self.soc = self.batt = None
|
||||
self.peak_fc = None
|
||||
@@ -214,8 +243,38 @@ class Controller:
|
||||
for msg in result.events:
|
||||
self.log_event(msg)
|
||||
|
||||
# --- SAFETY-02, and it runs BEFORE the early return below -------------
|
||||
# ⚠️ ORDER MATTERS HERE. If this were evaluated after the "inputs missing
|
||||
# but not yet stale" hold, a run of held cycles would leave
|
||||
# `disagree_since` untouched across the gap and the timer would resume
|
||||
# from a start time that predates it. It is evaluated every cycle,
|
||||
# unconditionally, so a missing meter CLEARS the window - see watchdog.py.
|
||||
#
|
||||
# The value compared is the command STANDING ON THE WIRE, which is what
|
||||
# this cycle's fresh meter reading is a response to. `last_write` is that
|
||||
# value after the device clamp and confirmed accepted; `target` covers
|
||||
# the case where nothing has been written yet (and, deliberately, the
|
||||
# case where the last write was REJECTED - the inverter is then still
|
||||
# latched on `last_write`, which is exactly what `last_write` holds).
|
||||
was_tripped = self.sign_wd.tripped
|
||||
standing = self.last_write if self.last_write is not None else self.target
|
||||
if self.sign_wd.evaluate(standing, self.grid, self.following, now) \
|
||||
and not was_tripped:
|
||||
# ⚠️ REASON FIRST, FLAG SECOND, and each `set` writes the file. The
|
||||
# ordering is the whole atomicity story: a crash between the two
|
||||
# persists a reason nothing reads, which is harmless, where the other
|
||||
# order persists a latch with no explanation for the operator who has
|
||||
# to decide whether to clear it.
|
||||
self.store.set("sign_reason", self.sign_wd.reason)
|
||||
self.store.set("sign_tripped", True)
|
||||
self.log_event("FAILSAFE " + self.sign_wd.reason)
|
||||
_LOG.error("SAFETY-02 TRIPPED - %s. Commanding 0 W and holding it "
|
||||
"until control is started again. This survives an add-on "
|
||||
"restart; restarting will not clear it.",
|
||||
self.sign_wd.reason)
|
||||
|
||||
stale_after = float(self.o.get("stale_input_s", 15))
|
||||
if not self.inputs_ok:
|
||||
if not self.inputs_ok and not self.sign_wd.tripped:
|
||||
bad_for = (now - self.inputs_bad_since).total_seconds() if self.inputs_bad_since else 0.0
|
||||
if bad_for < stale_after:
|
||||
# A single missed poll is not a fault. Hold, keep the heartbeat
|
||||
@@ -235,6 +294,16 @@ class Controller:
|
||||
claims.append(Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"))
|
||||
|
||||
# --- safety stops ----------------------------------------------------
|
||||
# ⚠️ SAFETY-02 is claimed FIRST and unconditionally while latched. It is
|
||||
# a SET at P_SAFETY, so it outranks maintenance, peak shaving and the
|
||||
# loop alike - a controller pushing power the wrong way is wrong
|
||||
# whatever it thinks it is doing. Re-filed EVERY cycle: claims are not
|
||||
# sticky, and one filed once would lapse the next cycle and hand the
|
||||
# actuator silently back to the loop that was driving the wrong way.
|
||||
if self.sign_wd.tripped:
|
||||
claims.append(Claim.set("failsafe", P_SAFETY, 0.0,
|
||||
"sign disagreement"))
|
||||
|
||||
if not self.auto:
|
||||
claims.append(Claim.set("safety", P_SAFETY, 0.0, "stopped"))
|
||||
elif not self.inputs_ok:
|
||||
@@ -306,6 +375,20 @@ class Controller:
|
||||
resolution = resolve(claims)
|
||||
if resolution.contradiction:
|
||||
self.log_event("ARBITER CONTRADICTION - commanding 0 W, see the log")
|
||||
# --- SAFETY-02's arming gate ------------------------------------------
|
||||
# Was the number about to go on the wire chosen by the grid-following
|
||||
# loop, or by a strategy that commands against the meter on purpose?
|
||||
# Only the former is expected to agree in sign with P1 - without this,
|
||||
# every maintenance grid charge trips the failsafe within three minutes.
|
||||
#
|
||||
# ⚠️ THE EXPRESSION LIVES IN watchdog.py, NOT HERE, and that is not
|
||||
# tidiness. It was inline, test_watchdog.py held a transcription of it,
|
||||
# and the P_PEAK case meant to force whoever lands peak shaving to come
|
||||
# and change an expectation did not: editing this line alone to
|
||||
# `winner in ("loop", "peak")` left every suite green while the watchdog
|
||||
# went blind for every peak event. Read loop_is_following() before
|
||||
# touching the gate - the forward hazard and the reasoning are there.
|
||||
self.following = loop_is_following(resolution, self.loop_w)
|
||||
self.target = resolution.target_w
|
||||
self.reason = resolution.explain()
|
||||
await self.write_setpoint(self.target)
|
||||
@@ -342,11 +425,85 @@ class Controller:
|
||||
last_grid = object()
|
||||
heartbeat = float(self.o.get("heartbeat_s", 10))
|
||||
last_beat = 0.0
|
||||
# ⚠️ SAFETY-12. The floor is a DEADLINE ON THE GAP BETWEEN CYCLES, not a
|
||||
# second scheduler running alongside the arrival trigger. Every cycle
|
||||
# resets it, whichever trigger fired, so on a healthy changing meter it
|
||||
# never elapses and not one existing cycle moves - and therefore no
|
||||
# change to the per-cycle gain the tuning was measured against.
|
||||
#
|
||||
# That is true twice over, and the second reason is the sturdier one:
|
||||
# the combined cycle rate is max(arrival rate, 1/floor), never the sum.
|
||||
# At the defaults 1/15 s is strictly slower than the ~1/5 s arrival
|
||||
# rate, so even a floor that raced the arrivals could not push the loop
|
||||
# past its nominal healthy rate. The re-tune is unreachable by
|
||||
# construction, not merely by the reset. ⚠️ That argument holds only
|
||||
# while floor > the meter's update interval - which is why the schema
|
||||
# minimum of 5 s deserves the second look validate.py has not given it
|
||||
# yet: 5 s IS the reference meter's interval, i.e. the one configurable
|
||||
# value that would double the cycle rate.
|
||||
#
|
||||
# Why it has to exist, and it is not only about latency: `self.grid !=
|
||||
# last_grid` alone means a meter that repeats a value runs NO control
|
||||
# cycles at all. The heartbeat below keeps re-emitting the last command
|
||||
# and the firmware keeps putting it on the wire, so every indicator
|
||||
# reads healthy - and, worse, the `inputs missing -> 0 W` claim lives
|
||||
# INSIDE cycle(), so on a repeating meter THAT SAFETY CLAIM CANNOT FIRE.
|
||||
# Demonstrated in test_loop.py: constant meter, SoC entity dies at t=4 s,
|
||||
# and the pre-fix controller holds 220 W through the whole outage with
|
||||
# the status line still reading "loop -> 220 W". Layer 1 does not cover
|
||||
# it on a `meter_source: off` install either - no P1 age sensor is
|
||||
# published, so the firmware has nothing to veto on. Measured on the rig
|
||||
# during TEL-05: 70 s at a literally constant 350.0 W, 14 arrivals, zero
|
||||
# cycles.
|
||||
#
|
||||
# This is NOT a freeze detector, and deliberately so - see
|
||||
# HomeWizardLocalSource.unchanged_s for why one cannot be built here (at
|
||||
# the converged -10 W target a 1 Wh register needs ~6 minutes to move,
|
||||
# so any freeze threshold false-trips at the exact operating point we
|
||||
# run at). Nothing here decides whether a repeated reading is true. It
|
||||
# only stops "the number is the same" from meaning "do not think".
|
||||
#
|
||||
# ⚠️ THE 15 s DEFAULT HAS A CEILING IT DOES NOT OWN. It is under
|
||||
# validate.FIRMWARE_INGEST_VETO_S (30 s) and under meter_max_age_s on
|
||||
# purpose, so the loop re-decides at least twice inside any window in
|
||||
# which layer 1 might otherwise be the only thing deciding. If the
|
||||
# firmware's veto ever moves, this default moves with it - it is not
|
||||
# independently justified at 15.
|
||||
floor = float(self.o.get("cycle_floor_s", 15))
|
||||
last_cycle = None
|
||||
while not self.stopping:
|
||||
await self.read_inputs()
|
||||
# A cycle is one meter update, exactly as on the reference install.
|
||||
if self.grid != last_grid:
|
||||
now_mono = asyncio.get_running_loop().time()
|
||||
# A cycle is one meter update, exactly as on the reference install -
|
||||
# or the floor elapsing, whichever comes first.
|
||||
overdue = last_cycle is None or (now_mono - last_cycle) >= floor
|
||||
if self.grid != last_grid or overdue:
|
||||
last_grid = self.grid
|
||||
last_cycle = now_mono
|
||||
# ⚠️ The FULL cycle, not a degraded one. A floor cycle runs the
|
||||
# same law on the same inputs as an arrival cycle, because in P1
|
||||
# mode the freshness question is already answered upstream and
|
||||
# answered harder: past `meter_max_age_s` (30 s) p1.net_w is
|
||||
# None, which is "inputs missing", which becomes a P_SAFETY 0 W
|
||||
# claim. So a floor cycle cannot run the PI on a 60 s old
|
||||
# figure, because at 60 s there is no figure.
|
||||
#
|
||||
# ⚠️ THAT GUARANTEE IS TRANSPORT-CONDITIONAL, and saying so
|
||||
# matters more than the guarantee: with `meter_source: off`,
|
||||
# read_inputs() takes self.grid straight from hass.number() with
|
||||
# NO age gate at all, so a Home Assistant entity that has gone
|
||||
# quiet reads as a current value on that path with or without
|
||||
# this change. Running the full law is still the right choice
|
||||
# there - the alternative is a degraded second law reasoning
|
||||
# about an age nobody measured - but the floor does not make
|
||||
# that path fresh, and nothing here should be read as claiming
|
||||
# it does. And the integrator
|
||||
# advances per CYCLE, not per second (control.py), so bounding
|
||||
# the gap bounds the accumulation: at most one extra
|
||||
# gain x error per floor interval, under the same
|
||||
# integrator_max_w as every other cycle. A second, gentler
|
||||
# control law for floor cycles would be a second set of
|
||||
# dynamics nobody can test on this hardware.
|
||||
await self.cycle()
|
||||
# ⚠️ The heartbeat is not an optimisation. The ESP32 treats silence
|
||||
# longer than ~30 s as "the controller is gone" and zeroes the
|
||||
@@ -365,7 +522,14 @@ class Controller:
|
||||
"battery": self.batt,
|
||||
"soc": self.soc,
|
||||
"phase": self.maint.phase,
|
||||
"status": "running" if self.auto else "stopped",
|
||||
# ⚠️ SAFETY-02's alarm surface, and it is deliberately an existing
|
||||
# one. IF-01/IF-02 own `ems/event/failsafe` and the `failsafe active`
|
||||
# binary sensor and neither is built yet; inventing a bespoke topic
|
||||
# here would be a surface to migrate later. This sensor is already
|
||||
# discovered, already on every dashboard, and "failsafe" is
|
||||
# additive to its vocabulary rather than a change to it.
|
||||
"status": ("failsafe" if self.sign_wd.tripped
|
||||
else "running" if self.auto else "stopped"),
|
||||
}
|
||||
# ⚠️ ONLY when P1 ingestion is actually running. The ESP32's stale-input
|
||||
# watchdog subscribes to sensor.goodwe_p1_sample_age - see the entity-id
|
||||
@@ -447,6 +611,23 @@ class Controller:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "last write to the inverter was REJECTED - check the log"})
|
||||
|
||||
# SAFETY-02. Reported in both states: a watchdog nobody can see is armed
|
||||
# is a watchdog nobody trusts when it fires.
|
||||
if self.sign_wd.tripped:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "SIGN-DISAGREEMENT FAILSAFE - " + self.sign_wd.reason
|
||||
+ ". The inverter is held at 0 W. Find out why the "
|
||||
"command opposed the meter before starting control "
|
||||
"again; starting clears this. Restarting the "
|
||||
"add-on does NOT clear it."})
|
||||
else:
|
||||
held = self.sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"sign watchdog: armed (trips after "
|
||||
f"{self.sign_wd.cfg.hold_s:.0f} s opposed, both over "
|
||||
f"{self.sign_wd.cfg.min_w:.0f} W)"
|
||||
+ (f" - opposed for {held:.0f} s now" if held else "")})
|
||||
|
||||
if not o.get("estop_fitted", False):
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": "no e-stop fitted: if this host dies the battery stays "
|
||||
@@ -464,7 +645,11 @@ class Controller:
|
||||
def status_payload(self) -> dict:
|
||||
checks = self.checks()
|
||||
bad = [c for c in checks if not c["ok"] and not c["warn"]]
|
||||
if bad:
|
||||
if self.sign_wd.tripped:
|
||||
# Outranks "NOT READY": nothing is missing, something went wrong.
|
||||
level, banner = "bad", ("FAILSAFE — the command opposed the meter. "
|
||||
"Inverter held at 0 W.")
|
||||
elif bad:
|
||||
level, banner = "bad", f"NOT READY — {bad[0]['text']}"
|
||||
elif not self.auto:
|
||||
level, banner = "warn", "Stopped — inverter commanded to 0 W"
|
||||
@@ -498,6 +683,17 @@ class Controller:
|
||||
self.auto = not self.auto
|
||||
self.store.set("auto", self.auto)
|
||||
self.log_event("control started" if self.auto else "control stopped")
|
||||
if self.auto and self.sign_wd.tripped:
|
||||
# ⚠️ THE ONLY WAY OUT OF A SIGN-DISAGREEMENT TRIP, on purpose.
|
||||
# It clears on a deliberate human start, not on the condition
|
||||
# going away - the condition ALWAYS goes away, because the trip
|
||||
# commands 0 W and a 0 W command cannot disagree with anything.
|
||||
# An operator pressing start has, at minimum, looked at the
|
||||
# banner that says why.
|
||||
self.sign_wd.reset()
|
||||
self.store.set("sign_tripped", False)
|
||||
self.store.set("sign_reason", "")
|
||||
self.log_event("sign-disagreement failsafe cleared by operator")
|
||||
if not self.auto:
|
||||
self.target = 0.0
|
||||
await self.write_setpoint(0.0, force=True)
|
||||
|
||||
@@ -28,9 +28,10 @@ _LOG = logging.getLogger("goodwe.maint")
|
||||
|
||||
IDLE, DRAIN, CHARGE, HOLD = "idle", "drain", "charge", "hold"
|
||||
|
||||
# A drain of a 13.5 kWh usable pack at 2500 W is ~5 h even with no house load
|
||||
# helping. 12 h means the battery is not following commands - a fault, not a
|
||||
# slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# A drain of a 13.8 kWh usable pack (300 Ah x 51.2 V, DoD 90) at the shipped
|
||||
# 2000 W is ~6.9 h even with no house load helping - and less in practice, since
|
||||
# house load drains alongside the export and soc_floor stops short of empty.
|
||||
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# it is expected to span a night; 36 h still bounds it.
|
||||
DRAIN_TIMEOUT_MIN = 720
|
||||
CHARGE_TIMEOUT_MIN = 2160
|
||||
|
||||
@@ -22,11 +22,30 @@ _LOG = logging.getLogger("goodwe.store")
|
||||
# `auto_start` option only when the key is absent - if a default supplied False,
|
||||
# the fallback could never fire and auto_start would silently do nothing on
|
||||
# every fresh install.
|
||||
#
|
||||
# ⚠️ `sign_tripped` IS in here, and the difference from `auto` is the whole
|
||||
# reason both decisions are written down. `auto` has an option to fall back to
|
||||
# (`auto_start`), so a stored default would mask a fresh install. A latched
|
||||
# failsafe has no such fallback: absent means "never tripped", which is exactly
|
||||
# what a default of False says.
|
||||
#
|
||||
# It is persisted for the reason this module's docstring gives for maintenance
|
||||
# state, applied to something with a much shorter fuse. SAFETY-02's latch is the
|
||||
# only thing standing between a controller that has been caught driving the wrong
|
||||
# way and its own restart, and "restart the add-on" is the FIRST thing an operator
|
||||
# looking at a FAILSAFE banner will try. Held only in memory it came back armed,
|
||||
# into the fault, unattended - measured: after reconstructing Controller against
|
||||
# the same store, `tripped` was False, the banner read NOT READY, and it resumed
|
||||
# commanding -1000, -2000 W before re-tripping 180 s later. Under a supervisor
|
||||
# that restarts a crashed add-on that is a loop, three minutes of wrong-direction
|
||||
# power at a time, forever.
|
||||
DEFAULTS = {
|
||||
"phase": "idle",
|
||||
"phase_started": None,
|
||||
"last_completed": None,
|
||||
"last_start_attempt": None,
|
||||
"sign_tripped": False,
|
||||
"sign_reason": "",
|
||||
}
|
||||
|
||||
|
||||
@@ -42,8 +61,10 @@ class Store:
|
||||
loaded = json.load(fh)
|
||||
if isinstance(loaded, dict):
|
||||
self.data = {**DEFAULTS, **loaded}
|
||||
_LOG.info("state restored: phase=%s last_completed=%s",
|
||||
self.data.get("phase"), self.data.get("last_completed"))
|
||||
_LOG.info("state restored: phase=%s last_completed=%s "
|
||||
"sign_tripped=%s",
|
||||
self.data.get("phase"), self.data.get("last_completed"),
|
||||
self.data.get("sign_tripped"))
|
||||
except FileNotFoundError:
|
||||
_LOG.info("no saved state, starting fresh")
|
||||
except (json.JSONDecodeError, OSError) as err:
|
||||
|
||||
@@ -74,6 +74,48 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
was overruled. That firmware file's own comment says a lower bound on this
|
||||
"belongs in CFG-01, not here" - so here it is.
|
||||
|
||||
5. `sign_disagree_w` at or above `max_w`. [(a)]
|
||||
The arbiter's `supervised` limit bounds every command to +-max_w, and
|
||||
SAFETY-02's predicate needs `abs(command) > sign_disagree_w`. Set the
|
||||
threshold at or above the ceiling and the command side of the comparison
|
||||
is unsatisfiable BY CONSTRUCTION: the watchdog can never fire, on any
|
||||
input, ever. Same shape as 1 and 4 - the operator set a number, a layer
|
||||
they cannot see makes it mean something else, and nothing says so. Worse
|
||||
here, because what the status page reports in that state is "sign
|
||||
watchdog: armed". A disarmed guard that advertises itself as armed is the
|
||||
one thing this project has decided repeatedly it will not ship.
|
||||
|
||||
6. `maintenance_charge_w` above `max_w`. [(a)]
|
||||
The same shape as 5, and found the same way - by checking a worked example
|
||||
against what actually ships. maintenance's cheap-window shaping files
|
||||
`Claim.limit(hi=-maintenance_charge_w)` at P_MAINT_SHAPE, against the
|
||||
`supervised` SAFETY limit's `lo=-max_w`. Both bind (P_SAFETY and
|
||||
P_MAINT_SHAPE both outrank the loop that wins the SET), so a charge rate
|
||||
above the ceiling gives `lo > hi` - the arbiter's clause 3, which it
|
||||
correctly resolves to 0 W and logs as a CONTRADICTION. Measured against
|
||||
the arbiter, loop asking +500 W:
|
||||
|
||||
max_w=2000 hi=-2500 -> +0 W contradiction=True
|
||||
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
|
||||
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(...)
|
||||
|
||||
So MAINTENANCE SILENTLY NEVER CHARGES IN A CHEAP WINDOW until max_w is at
|
||||
or above the charge rate, and the only evidence is a contradiction line
|
||||
that reads like a bug in the arbiter rather than like the two numbers the
|
||||
operator set. Equality is fine and deliberately not refused - at
|
||||
max_w == charge_w the window is a single reachable point, -max_w.
|
||||
|
||||
⚠️ `maintenance_discharge_w` IS NOT THE SAME CASE, and this was checked
|
||||
rather than assumed. THE SHAPING IS NOT SYMMETRIC: the drain phase does
|
||||
not shape the loop, it OWNS the actuator - `Claim.set(P_MAINTENANCE,
|
||||
+discharge_w)`. A SET is clamped by the limits above it, not contradicted
|
||||
by them, so 2500 against a 2000 W ceiling emits +2000 W and the arbiter's
|
||||
own explain() says `maintenance -> 2000 W, limited by supervised(max_w)`
|
||||
on the status page every cycle. That is neither (a) - nothing is silent -
|
||||
nor (b) - it moves energy and the cycle still completes, just slower
|
||||
(13.8 kWh usable at 2000 W is ~6.9 h against the 720 min DRAIN_TIMEOUT).
|
||||
It is warned about below, not refused.
|
||||
|
||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
|
||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||
@@ -91,6 +133,9 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
NOT READY banner.
|
||||
- `meter_poll_s` above half `meter_max_age_s`. One missed poll costs a stale
|
||||
reading and a 0 W cycle. Warned about in p1.py, not refused.
|
||||
- `maintenance_discharge_w` above `max_w`. Clamped, not contradicted, and the
|
||||
clamp names itself in the arbiter's explain() - see rule 6. Warned about,
|
||||
not refused.
|
||||
"""
|
||||
|
||||
import logging
|
||||
@@ -238,6 +283,72 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
"or rebuild the firmware with a matching max_age_s and update "
|
||||
"validate.FIRMWARE_INGEST_VETO_S.")
|
||||
|
||||
# --- 5. a sign watchdog that can actually fire ---------------------------
|
||||
# ⚠️ Strictly `>=`, matching the predicate exactly: watchdog.py tests
|
||||
# `abs(commanded_w) > min_w`, and the arbiter holds `abs(commanded_w)` at or
|
||||
# below max_w, so threshold == max_w is already unsatisfiable. Anything
|
||||
# BELOW max_w is reachable and therefore fine - this refuses the disarmed
|
||||
# case only, not "close to the rail".
|
||||
sign_w = _number(opts, "sign_disagree_w", 300.0)
|
||||
if sign_w is None:
|
||||
problems.append(f"sign_disagree_w {opts.get('sign_disagree_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and sign_w >= max_w:
|
||||
problems.append(
|
||||
f"sign_disagree_w is {sign_w:.0f} W but max_w is {max_w:.0f} W, so "
|
||||
"the SAFETY-02 sign-disagreement watchdog can never fire: the "
|
||||
"arbiter never lets a command exceed max_w, and the watchdog needs "
|
||||
f"a command over {sign_w:.0f} W. It would sit there reporting "
|
||||
"'armed' on the status page while being incapable of tripping - the "
|
||||
f"one runaway failure mode this system has actually observed. Lower "
|
||||
f"sign_disagree_w below {max_w:.0f} W (300 W is the measured "
|
||||
"default), or raise max_w.")
|
||||
|
||||
# --- 6. a maintenance charge the ceiling can actually accommodate --------
|
||||
# ⚠️ Strictly `>`, matching the arbiter exactly. The shaping is
|
||||
# `Claim.limit(hi=-charge_w)` against `supervised`'s `lo=-max_w`, so
|
||||
# charge_w == max_w leaves the single reachable point -max_w and works;
|
||||
# only ABOVE is `lo > hi`, arbiter clause 3, 0 W and a contradiction.
|
||||
#
|
||||
# Not scoped to maintenance_enabled, deliberately. The pair is
|
||||
# contradictory whether or not the schedule is on, and scoping it would
|
||||
# leave the trap armed for the one operator action - ticking
|
||||
# maintenance_enabled - that cannot possibly be expected to change what a
|
||||
# charge rate means.
|
||||
# ⚠️ THE FALLBACK IS config.yaml's SHIPPED VALUE, and it has to be kept
|
||||
# equal to it - that is the whole point of AC3. It is reachable only when a
|
||||
# caller hands over a dict with the key missing (sim/inject.py, a test); the
|
||||
# Supervisor always supplies every key from config.yaml, so on a real
|
||||
# install the argument is always present.
|
||||
#
|
||||
# ⚠️ KNOWN MISMATCH, LEFT DELIBERATELY AND FLAGGED RATHER THAN FIXED HERE:
|
||||
# `main.py` still falls back to 2500 in two places
|
||||
# (`opts.get("maintenance_charge_w", 2500)`), as does maintenance.py's
|
||||
# MaintConfig dataclass. So a dict with the key ABSENT is accepted by this
|
||||
# rule at 2000 and then built by main.py at 2500 - the contradiction this
|
||||
# rule exists to catch, in the one case it cannot see. It is unreachable on
|
||||
# a Supervisor install and those files are another ticket's right now.
|
||||
# THE REAL FIX is one source of truth for option defaults; until then the
|
||||
# divergence is PINNED BY A CHECK rather than by this comment - see
|
||||
# test_validate.py, "the KNOWN cross-file default divergence". It asserts
|
||||
# the mismatch as it stands and goes red if EITHER side moves, including
|
||||
# when somebody closes it in main.py, at which point this block and that
|
||||
# check both get deleted.
|
||||
charge_w = _number(opts, "maintenance_charge_w", 2000.0)
|
||||
if charge_w is None:
|
||||
problems.append(
|
||||
f"maintenance_charge_w {opts.get('maintenance_charge_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and charge_w > max_w:
|
||||
problems.append(
|
||||
f"maintenance_charge_w is {charge_w:.0f} W but max_w is "
|
||||
f"{max_w:.0f} W, so a maintenance charge in a cheap window can "
|
||||
"never happen: the shaping asks the arbiter for at most "
|
||||
f"{-charge_w:.0f} W while the supervised limit allows no less than "
|
||||
f"{-max_w:.0f} W, which is a contradiction it resolves to 0 W - "
|
||||
"THE CEILING WINS, and what you would see is an ARBITER "
|
||||
"CONTRADICTION line that reads like a bug rather than like these "
|
||||
f"two numbers. Lower maintenance_charge_w to {max_w:.0f} W or less, "
|
||||
f"or raise max_w to at least {charge_w:.0f} W.")
|
||||
|
||||
# --- warnings: real, but not worth refusing over -------------------------
|
||||
integ = opts.get("integrator_max_w")
|
||||
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
|
||||
@@ -249,6 +360,25 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
"saturation. 0 (follow max_w) is the recommended value.",
|
||||
integ_w, max_w)
|
||||
|
||||
# ⚠️ THE SIBLING OF RULE 6, AND NOT THE SAME CASE - see the docstring. The
|
||||
# drain phase OWNS the actuator (`Claim.set` at P_MAINTENANCE), and a SET is
|
||||
# clamped by the limits above it rather than contradicted by them. So this
|
||||
# drains at max_w instead of the configured rate, the arbiter says so in
|
||||
# words on the status page every cycle, and the cycle still completes -
|
||||
# slower, and eating into maintenance.DRAIN_TIMEOUT_MIN. Loud and it moves
|
||||
# energy, so it is neither (a) nor (b): warned, not refused.
|
||||
disch_w = _number(opts, "maintenance_discharge_w", 2000.0)
|
||||
if disch_w is not None and max_w is not None and max_w > 0 and disch_w > max_w:
|
||||
_LOG.warning(
|
||||
"maintenance_discharge_w %.0f W is above max_w %.0f W. Not refused - "
|
||||
"the drain phase SETS the setpoint and the arbiter clamps it to "
|
||||
"%.0f W and names the clamp ('limited by supervised(max_w)'), so "
|
||||
"nothing is silent and the cycle still completes. But it drains at "
|
||||
"%.0f W, not the %.0f W you configured, and the drain phase has a "
|
||||
"720 min timeout. Lower it to %.0f W or raise max_w to remove the "
|
||||
"surprise.",
|
||||
disch_w, max_w, max_w, max_w, disch_w, max_w)
|
||||
|
||||
return problems
|
||||
|
||||
|
||||
|
||||
@@ -0,0 +1,354 @@
|
||||
"""SAFETY-02 - the sign-disagreement watchdog.
|
||||
|
||||
WHAT IT CATCHES, in one sentence: a grid-following loop that is pushing power in
|
||||
the wrong direction, which every other guard in this system is blind to.
|
||||
|
||||
The stale-input watchdog (SAFETY-01) asks "is the meter still talking?". The
|
||||
saturation freeze asks "can the inverter follow?". The output clamp asks "is the
|
||||
number too big?". A loop can pass all three and still be charging the battery
|
||||
out of the grid while the house imports - the meter is fresh, the inverter is
|
||||
tracking beautifully, and the magnitude is inside the rating. The only thing
|
||||
that separates that from healthy operation is the SIGN.
|
||||
|
||||
⚠️ THIS IS NOT A HYPOTHETICAL. On 2026-08-20 the vendor controller (Illusmart)
|
||||
did exactly this four times in one day (NOTES.md §4.7). Both captures of that
|
||||
bus are committed - `sim/scenarios/bus-2026-08-20.log.gz` and the healthy
|
||||
`bus-2026-08-23.log.gz` in the infra repo - and `sim/replay_sign.py` drives this
|
||||
module over both of them. Every number in this file was measured on those two
|
||||
days, not chosen:
|
||||
|
||||
day samples gated in sign agreement
|
||||
2026-08-23 4 212 / 17 280 93.4 % (healthy)
|
||||
2026-08-20 7 182 / 17 280 56.4 % (the whole fault day)
|
||||
cluster A 15:26-16:43 0.3 %
|
||||
cluster B 17:11-18:28 0.9 %
|
||||
cluster C 20:01-20:31 10.5 %
|
||||
cluster D 20:55-21:11 0.0 %
|
||||
|
||||
⚠️ THOSE AGREEMENT FIGURES ARE THE WEAKEST EVIDENCE ON THIS PAGE, and an earlier
|
||||
version of this comment leaned on them as though they were the strongest. The
|
||||
clusters are found by looking for sustained opposed samples, so measuring "how
|
||||
opposed is this cluster" over them is close to a tautology - and "the healthy day
|
||||
contains no such cluster" is the same sentence as "the healthy day produces no
|
||||
trip", not independent corroboration of it.
|
||||
|
||||
What actually carries the argument is two things neither the detector nor the
|
||||
clustering assumes:
|
||||
|
||||
1. The RUN-LENGTH DISTRIBUTION. The longest unbroken opposed run on the healthy
|
||||
day is 30 s. On the fault day there are 18 runs over 180 s and the longest is
|
||||
1750 s. Nothing about that gap was chosen - it is what the two days measure.
|
||||
2. The clusters land where a human independently wrote down onsets. NOTES.md
|
||||
§4.7 records 15:01, 16:56, 19:57 and 20:23 from watching it happen, before
|
||||
any of this existed, and cluster D coincides with the separately documented
|
||||
inverter-off runaway of §4.7 item 2.
|
||||
|
||||
Be precise about (2), because the convenient overstatement is available and wrong:
|
||||
the clustering does NOT reproduce four episodes. It yields THREE clusters over the
|
||||
four documented onsets - C spans both 19:57 and 20:23 - plus a fourth for §4.7
|
||||
item 2, which is not one of the four. Every trip does fall inside a documented
|
||||
window, which is the claim worth making.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY IT LIVES HERE AND NOT IN THE FIRMWARE OR THE WITNESS
|
||||
|
||||
Three vantage points see three different things. The firmware knows what it
|
||||
WROTE, the witness Pi knows what was ON THE WIRE and whether the inverter ACKed
|
||||
it, and the add-on knows what it INTENDED and holds the authoritative meter.
|
||||
|
||||
This check is not command-versus-wire; it is command-versus-physics. It needs
|
||||
the emitted setpoint and the P1 net figure in the same place, and it needs the
|
||||
authority to command zero when they fight:
|
||||
|
||||
- the witness is read-only by charter and cannot command anything, so it could
|
||||
raise the alarm but never take the trip action the AC requires;
|
||||
- the firmware has the wire but not the meter. §5.1 makes P1 the only
|
||||
authoritative grid figure and the board only ever receives its AGE
|
||||
(`sensor.goodwe_p1_sample_age`), never its value. Putting the check there
|
||||
would mean shipping the meter to the ESP32 for no other reason, and it would
|
||||
be C++ per install rather than one generic guard;
|
||||
- the add-on has both halves already, plus an arbiter that can outrank every
|
||||
strategy with a P_SAFETY claim.
|
||||
|
||||
The cost of standing here is real and worth stating: this watchdog compares what
|
||||
we MEANT to put on the wire against the meter. If the firmware or the driver
|
||||
inverts the sign on the way out, the add-on's own view still agrees with itself
|
||||
and this check stays silent. That gap is a wire-versus-intent problem and it
|
||||
belongs to the witness, not here.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT "DISAGREEMENT" MEANS, PRECISELY
|
||||
|
||||
disagree = following
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > min_w
|
||||
and abs(grid_w) > min_w
|
||||
|
||||
Four gates, and each one exists to exclude a specific thing that is NOT a fault:
|
||||
|
||||
1. `following`. ⚠️ THE GATE THAT IS EASIEST TO FORGET AND MOST EXPENSIVE TO
|
||||
OMIT. Sign agreement is a property of a GRID-FOLLOWING loop. It is not
|
||||
expected of a strategy that deliberately commands against the meter -
|
||||
maintenance is exactly that. A maintenance grid charge of 1500 W into a house
|
||||
drawing 500 W puts +2000 W on the meter against a -1500 W command: opposed,
|
||||
both far over any sane threshold, and sustained for HOURS. Armed
|
||||
unconditionally this watchdog would trip on every single maintenance cycle,
|
||||
which is not a tuning problem, it is the wrong question being asked. So the
|
||||
caller says whether the grid-following loop actually won the arbitration this
|
||||
cycle, and the timer only accumulates when it did.
|
||||
|
||||
⚠️ 1500 W, NOT THE DEFAULT 2500 W, AND THE REASON IS NOT COSMETIC. At the
|
||||
shipped defaults `maintenance_charge_w` is 2500 and `max_w` is 2000, so the
|
||||
cheap-window claim is `hi = -2500` against a supervised `lo = -2000`: lo > hi,
|
||||
which arbiter.py resolves as a CONTRADICTION and 0 W, not as a -2500 W charge.
|
||||
The example above is written at 1500 W because that is a combination the
|
||||
schema and the arbiter both actually produce. (The contradiction at the
|
||||
defaults is a real pre-existing bug - a default maintenance charge silently
|
||||
never happens in a cheap window - but it is maintenance's, not this module's,
|
||||
and it is filed separately. Do not "fix" it here.)
|
||||
|
||||
2. The strict `< 0` product. "Opposed" and "neither side is zero" in one
|
||||
expression.
|
||||
|
||||
3. The 300 W magnitude gate ON BOTH SIDES. Near zero the sign is noise, and near
|
||||
zero is where a healthy loop LIVES - the deadband holds the command still
|
||||
while the meter wanders either side of `target_grid_w`. On the healthy day
|
||||
only 4 212 of 17 280 samples (24 %) are even gated in; the other 76 % are the
|
||||
converged band where sign carries no information. This is also why the
|
||||
deadband cannot produce a false trip: inside it the meter is by definition
|
||||
under 300 W.
|
||||
|
||||
4. The 180 s continuity requirement. This is what excludes the legitimate
|
||||
transient. A load step reverses the meter's sign instantly while the command
|
||||
is still where the last cycle left it; slew limiting then needs a few cycles
|
||||
to cross over. Measured on the healthy day, the LONGEST such crossing is 30 s
|
||||
- and that is with a vendor controller far cruder than ours. 180 s is six
|
||||
times that. It is not a fitted threshold: at 60 s the healthy day still
|
||||
produces zero trips, and at 300 s the fault day still produces 13.
|
||||
|
||||
⚠️ A BATTERY THAT REFUSES A COMMAND CANNOT TRIP THIS, and that is structural
|
||||
rather than lucky. At SoC 10 % in Standby, a 1350 W discharge command into a
|
||||
1350 W import is DECLINED: the battery does nothing, so the meter stays at
|
||||
+1350 W and the command stays at +1350 W. Same sign. Agreement. A refusal leaves
|
||||
the meter where it was; only the inverter ACTING moves it, and acting in the
|
||||
commanded direction moves it toward zero, not through it. The failure mode this
|
||||
check keys on is the opposite of a refusal - it is the inverter obediently doing
|
||||
a wrong thing.
|
||||
|
||||
⚠️ A FROZEN METER cannot trip it either, for the same reason read the other way:
|
||||
a stuck reading of +800 W makes the loop command discharge and keep commanding
|
||||
discharge. Command and meter converge on AGREEING. Freezes are SAFETY-12's and
|
||||
SAFETY-01's problem, and this watchdog neither helps nor hinders there.
|
||||
|
||||
⚠️ ALL OF THAT DEPENDS ON ONE PROPERTY OF THE CONTROL LAW, so it is an invariant
|
||||
and not a happy accident: the saturation freeze in control.py must keep letting
|
||||
the command FALL, CROSS ZERO AND REVERSE - "may not wind further in the direction
|
||||
it is already pushing", not "only corrections that shrink |i_w|". control.py
|
||||
records the shrink-only encoding as tried and rejected because it pins the command
|
||||
at its last value indefinitely; a pinned command against a meter that has moved on
|
||||
is precisely a sustained sign disagreement, so under that encoding this watchdog
|
||||
WOULD false-trip on a plain load step. If anyone ever revisits that freeze, this
|
||||
module's no-false-positive argument is downstream of the answer.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT IT DOES NOT CATCH
|
||||
|
||||
An inverter that ACTS opposite to what it was told. Tell it to discharge 2000 W
|
||||
and have it charge instead, and the meter moves FURTHER the way it was already
|
||||
going - so the command and the meter agree, all the way into the rail. This
|
||||
watchdog compares the loop's output direction against the input state it was
|
||||
regulating; it is blind to the plant lying about which way it went. That is the
|
||||
saturation freeze's question (|command - the battery's actual power| > 500 W,
|
||||
NOTES.md §4.7 row 4), and the two checks are complementary rather than
|
||||
overlapping. Neither substitutes for the other.
|
||||
|
||||
Nor does it see a sign inversion introduced DOWNSTREAM of this add-on - in the
|
||||
firmware, on the wire, or in a future driver. Our view stays self-consistent and
|
||||
this stays silent. That is a wire-versus-intent problem and it belongs to the
|
||||
witness, which is the only vantage point that sees both.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
STATE, TRIP AND LATCH
|
||||
|
||||
One timestamp, not a sample counter. The cycle rate is not fixed - a meter
|
||||
arrival, or `cycle_floor_s` elapsing, whichever comes first - so N samples is a
|
||||
different wall-clock window on every path, and the AC is written in minutes.
|
||||
|
||||
The latch is not optional and not a nicety. Commanding 0 W removes the command
|
||||
side of the comparison (|0| is not > 300), so the disagreement disappears the
|
||||
instant the trip works. Un-latched, this watchdog would trip, clear itself, and
|
||||
hand the actuator straight back to the loop that was driving the wrong way -
|
||||
three minutes later, forever. `tripped` therefore stays true until an operator
|
||||
`reset()`s it by starting control again, which is a deliberate human act after
|
||||
looking at why.
|
||||
|
||||
⚠️ AND THE LATCH HAS TO OUTLIVE THE PROCESS. Held only in memory it is not a
|
||||
latch at all - a container restart clears it and the add-on comes back armed,
|
||||
into the same fault, unattended. Worse than merely losing state: "restart the
|
||||
add-on" is the first thing an operator confronted with a FAILSAFE banner and a
|
||||
0 W inverter will try, and under a supervisor that restarts a crashed add-on it
|
||||
is a loop of three-minute wrong-direction bursts. `tripped` and `reason` are
|
||||
therefore constructor arguments, restored from `Store` in `Controller.__init__`
|
||||
and written back the moment the trip happens. See store.py.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class SignWatchdogConfig:
|
||||
"""Defaults, not constants - config.yaml carries both (SAFETY-02 AC 5)."""
|
||||
|
||||
min_w: float = 300.0
|
||||
hold_s: float = 180.0
|
||||
|
||||
|
||||
def disagrees(commanded_w, grid_w, following: bool,
|
||||
cfg: SignWatchdogConfig) -> bool:
|
||||
"""The predicate, and the ONLY place it is written down.
|
||||
|
||||
⚠️ Public because `sim/replay_sign.py` needs it too - to describe episodes, to
|
||||
measure agreement, to sweep the clock-skew guard - and it had reimplemented it
|
||||
inline. Two copies of a safety predicate is one copy plus a future
|
||||
disagreement about what the check means, and the copy that drifts is always
|
||||
the one in the harness that grades it.
|
||||
"""
|
||||
return (following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w)
|
||||
|
||||
|
||||
def loop_is_following(resolution, loop_asked) -> bool:
|
||||
"""Did the grid-following loop actually choose the number going on the wire?
|
||||
|
||||
Gate 1 of the predicate above, and it lives here rather than inline in
|
||||
`cycle()` for the reason `disagrees()` does: the test suite has to be able to
|
||||
assert on THE SHIPPED EXPRESSION, not on a transcription of it that drifts
|
||||
apart from it in silence.
|
||||
|
||||
⚠️ IT WAS A TRANSCRIPTION, AND THAT WAS MEASURED, NOT FEARED. The P_PEAK case
|
||||
in test_watchdog.py exists to make whoever lands peak shaving come here and
|
||||
change an expectation. With the expression copied into the test it did not do
|
||||
that: editing the shipped gate alone to `winner in ("loop", "peak")` left every
|
||||
suite green while the watchdog went blind for the whole of every peak event.
|
||||
One definition, two callers, and that test now bites.
|
||||
|
||||
`resolution` the arbiter's Resolution. Duck-typed on `.winner` and
|
||||
`.target_w` so this module still imports nothing from arbiter.
|
||||
`loop_asked` what the grid-following loop claimed this cycle, or None if it
|
||||
did not claim at all.
|
||||
|
||||
"The loop won" is NOT the question, and the difference is a whole class of
|
||||
false trip. A LIMIT claim can survive the loop winning and still replace its
|
||||
number: maintenance's cheap-window shaping is `hi = -maintenance_charge_w`, so
|
||||
at 1500 W the loop can ask for +500 W of discharge, win the arbitration, and
|
||||
have the emitted value come out at -1500 W of grid charge. Winner says "loop";
|
||||
the wire carries maintenance's intent.
|
||||
|
||||
So the test is on the NUMBER: the loop is following only while the emitted
|
||||
value points the way the loop asked AND is no larger than it asked - limits
|
||||
reduced it, they did not redirect it. The magnitude half is load-bearing on
|
||||
its own, because a `lo` limit can raise magnitude without flipping sign, and
|
||||
that is not the loop following either. Zero on either side falls out as
|
||||
not-following, which costs nothing: a 0 W command cannot be a
|
||||
wrong-direction command.
|
||||
|
||||
⚠️ FORWARD HAZARD, and the claim block in cycle() already anticipates it.
|
||||
`winner == "loop"` disarms the watchdog under ANY higher-priority SET claim.
|
||||
Today only maintenance and the safety stops emit one and neither follows the
|
||||
meter, so the gate costs nothing. A peak-shaving strategy claiming SET at
|
||||
P_PEAK **is** grid-following in sign, and the moment it lands this goes blind
|
||||
for the duration of every peak event. Widening it means asking "does the
|
||||
winning strategy follow the meter", not adding another name to a comparison.
|
||||
"""
|
||||
return (resolution.winner == "loop" and loop_asked is not None
|
||||
and resolution.target_w * loop_asked > 0
|
||||
and abs(resolution.target_w) <= abs(loop_asked))
|
||||
|
||||
|
||||
class SignWatchdog:
|
||||
"""One instance per actuator, evaluated once per control cycle.
|
||||
|
||||
⚠️ NOT SHARED ACROSS CADENCES. `disagree_since` is a wall-clock start time,
|
||||
so driving one instance from two loops at two rates would have each one
|
||||
resetting the other's window. If a fast on-device path ever wants this
|
||||
check, it gets its own instance - the same exactly-one-writer discipline the
|
||||
arbiter applies to the actuator, applied to the detector's own state.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None, *,
|
||||
tripped: bool = False, reason: str = ""):
|
||||
self.cfg = cfg or SignWatchdogConfig()
|
||||
self.disagree_since: datetime | None = None
|
||||
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED. A latch that lives only in
|
||||
# memory is not a latch: a container restart clears it, and the add-on
|
||||
# comes back armed, into the same fault, with no operator involved. See
|
||||
# store.py's note on `sign_tripped` for the measured behaviour.
|
||||
self.tripped = bool(tripped)
|
||||
self.reason = reason if self.tripped else ""
|
||||
|
||||
# -- the whole check, and it is a pure function of its arguments ----------
|
||||
def evaluate(self, commanded_w, grid_w, following: bool,
|
||||
now: datetime) -> bool:
|
||||
"""Advance the detector one cycle. Returns True while tripped.
|
||||
|
||||
`commanded_w` the EMITTED setpoint - what is standing on the wire now,
|
||||
after deadband, slew, quantisation and the arbiter. Not
|
||||
the optimizer's raw wish: the wire carries the emitted
|
||||
value, so anything else can disagree with the meter for a
|
||||
reason that is not a fault.
|
||||
`grid_w` net P1, + = importing. None when the meter is stale or
|
||||
missing, which CLEARS the timer rather than accumulating
|
||||
- a frozen figure held against a moving command would
|
||||
otherwise manufacture a disagreement in about three
|
||||
minutes, on top of SAFETY-01 having already commanded
|
||||
zero for the same cause.
|
||||
`following` did the grid-following loop actually win this cycle? See
|
||||
gate 1 in the module docstring.
|
||||
`now` the caller's clock, so this stays testable and replayable.
|
||||
"""
|
||||
if self.tripped:
|
||||
# Latched. Do not re-evaluate: the trip removed the evidence.
|
||||
return True
|
||||
|
||||
cfg = self.cfg
|
||||
if not disagrees(commanded_w, grid_w, following, cfg):
|
||||
self.disagree_since = None
|
||||
return False
|
||||
|
||||
if self.disagree_since is None:
|
||||
self.disagree_since = now
|
||||
return False
|
||||
|
||||
held = (now - self.disagree_since).total_seconds()
|
||||
if held < cfg.hold_s:
|
||||
return False
|
||||
|
||||
self.tripped = True
|
||||
self.reason = (
|
||||
f"SIGN_DISAGREEMENT: commanded {commanded_w:+.0f} W against a meter "
|
||||
f"reading {grid_w:+.0f} W for {held:.0f} s continuously "
|
||||
f"(limits: both over {cfg.min_w:.0f} W, held over {cfg.hold_s:.0f} s)"
|
||||
)
|
||||
return True
|
||||
|
||||
def held_s(self, now: datetime) -> float:
|
||||
"""How long the current disagreement has been standing, for the UI.
|
||||
|
||||
⚠️ Takes the clock rather than reading one. It was a property calling
|
||||
`datetime.now()`, which quietly broke the property this module's header
|
||||
advertises - every other observable here is a pure function of what it
|
||||
was handed - and an unclocked function is one nothing can test, which is
|
||||
exactly what happened to it.
|
||||
"""
|
||||
if self.disagree_since is None:
|
||||
return 0.0
|
||||
return (now - self.disagree_since).total_seconds()
|
||||
|
||||
def reset(self) -> None:
|
||||
self.disagree_since = None
|
||||
self.tripped = False
|
||||
self.reason = ""
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.4.0"
|
||||
version: "0.5.1"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -90,14 +90,51 @@ options:
|
||||
integrator_max_w: 0
|
||||
heartbeat_s: 10
|
||||
stale_input_s: 15
|
||||
cycle_floor_s: 15
|
||||
auto_start: false
|
||||
|
||||
# --- SAFETY-02 sign-disagreement watchdog ----------------------------------
|
||||
# Trips when the emitted setpoint and the P1 net figure point OPPOSITE ways,
|
||||
# both over sign_disagree_w, continuously for sign_disagree_s. Action: 0 W and
|
||||
# a failsafe that latches until an operator starts control again.
|
||||
#
|
||||
# Both defaults are measured, not chosen. On the captured healthy day
|
||||
# (2026-08-23) the longest legitimate opposed run - a load step the loop has
|
||||
# not caught up with - is 30 s, and sign agreement over the gated samples is
|
||||
# 93.4 %. On the captured fault day (2026-08-20) the clusters run 0.0-10.5 %
|
||||
# agreement with opposed runs up to 1752 s. 300 W / 180 s sits in the middle of
|
||||
# a very wide gap: at 60 s the healthy day still trips nothing, at 300 s the
|
||||
# fault day still trips 13 times. There is no reason to move either number
|
||||
# without a capture that says so. They are options because the AC says
|
||||
# thresholds are defaults rather than constants - not because they are knobs
|
||||
# anyone is expected to turn.
|
||||
#
|
||||
# ⚠️ sign_disagree_w must stay BELOW max_w or the watchdog can never fire (the
|
||||
# arbiter bounds the command to +-max_w). validate.py refuses that config.
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- maintenance -----------------------------------------------------------
|
||||
maintenance_enabled: false
|
||||
maintenance_interval_days: 28
|
||||
maintenance_start_hour: 10
|
||||
maintenance_discharge_w: 2500
|
||||
maintenance_charge_w: 2500
|
||||
# ⚠️ BOTH MUST STAY AT OR BELOW max_w, and that is why they are 2000 rather
|
||||
# than the 2500 they shipped as. The cheap-window charge shaping asks the
|
||||
# arbiter for `hi = -maintenance_charge_w` against the supervised `lo =
|
||||
# -max_w`: above the ceiling that is `lo > hi`, a contradiction resolved to
|
||||
# 0 W, so maintenance would SILENTLY NEVER CHARGE in a cheap window on a
|
||||
# default install. validate.py refuses that config (rule 6), so these
|
||||
# defaults had to become self-consistent with the max_w above rather than
|
||||
# ship a configuration the validator rejects.
|
||||
#
|
||||
# The discharge side is clamped rather than contradicted - it drains at max_w
|
||||
# and the arbiter says so - so it is only warned about; it is 2000 here for
|
||||
# symmetry and to keep the shipped config warning-free.
|
||||
#
|
||||
# Raising max_w (the live reference install runs 5000) is what unlocks a
|
||||
# faster maintenance cycle. Raise max_w FIRST, then these.
|
||||
maintenance_discharge_w: 2000
|
||||
maintenance_charge_w: 2000
|
||||
maintenance_soc_floor: 11
|
||||
maintenance_soc_target: 99
|
||||
maintenance_hold_min: 120
|
||||
@@ -151,8 +188,14 @@ schema:
|
||||
integrator_max_w: int(0,15000)
|
||||
heartbeat_s: int(2,25)
|
||||
stale_input_s: int(5,120)
|
||||
cycle_floor_s: int(5,60)
|
||||
auto_start: bool
|
||||
|
||||
# No "off" value, deliberately: this is a P0 safety check and the schema is
|
||||
# not the place to make disarming it a supported configuration.
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
maintenance_enabled: bool
|
||||
maintenance_interval_days: int(1,90)
|
||||
maintenance_start_hour: int(0,23)
|
||||
|
||||
@@ -0,0 +1,213 @@
|
||||
"""Runnable check for the control loop's cadence. `python3 test_loop.py`
|
||||
|
||||
SAFETY-12: the loop must evaluate on a clock as well as on a change. Before the
|
||||
fix, `run_control()` ran `cycle()` only when the meter value differed from the
|
||||
previous poll, so a meter that repeats a value ran NO control cycles while the
|
||||
heartbeat kept re-emitting the last command - measured on the rig during TEL-05
|
||||
as 70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.
|
||||
|
||||
⚠️ THIS TEST TAKES ~95 SECONDS OF WALL CLOCK (measured 93 s), on purpose, and
|
||||
that figure is the only thing standing between it and a future developer who
|
||||
decides a slow test is a broken one. The thing under test is a wall-clock floor
|
||||
inside a loop that sleeps 1 s; mocking the clock would leave the assertion
|
||||
testing the mock. It drives the real `run_control()` and counts what actually
|
||||
happened. Eight runs of the real loop is what the eight scenarios cost.
|
||||
|
||||
⚠️ If you shorten the windows, re-measure and update this number and the one in
|
||||
HANDOVER.md. An understated runtime reads as a hang.
|
||||
|
||||
`cycle_floor_s` is read from options with no lower bound in code, so a huge
|
||||
value reproduces the pre-fix behaviour exactly. Every claim below is therefore
|
||||
an A/B on one binary, not a comparison against a remembered old one.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import sys
|
||||
import time
|
||||
|
||||
from app.main import Controller
|
||||
|
||||
fails = []
|
||||
NEVER = 1e9 # cycle_floor_s so large the floor can never elapse: pre-fix
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
class FakeHass:
|
||||
"""A scripted meter and a plant that tracks the command instantly."""
|
||||
|
||||
def __init__(self, meter, soc_dies_at=None):
|
||||
self.meter = meter
|
||||
self.soc_dies_at = soc_dies_at
|
||||
self.batt = 0.0
|
||||
self.writes = []
|
||||
self.t0 = time.monotonic()
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
now = time.monotonic() - self.t0
|
||||
if entity == "sensor.grid":
|
||||
return self.meter(now)
|
||||
if entity == "sensor.batt":
|
||||
return self.batt
|
||||
if entity == "sensor.soc":
|
||||
if self.soc_dies_at is not None and now >= self.soc_dies_at:
|
||||
return None
|
||||
return 50.0
|
||||
return None
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
self.batt = float(value)
|
||||
return True
|
||||
|
||||
|
||||
class _Store:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
BASE = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": 0.6, "slew_w": 1000,
|
||||
"deadband_w": 15, "target_grid_w": -10, "step_w": 10,
|
||||
"heartbeat_s": 10, "stale_input_s": 15}
|
||||
|
||||
|
||||
def drive(meter, floor, seconds, soc_dies_at=None, **over):
|
||||
"""Run the real control loop for `seconds`; return (cycle times, writes)."""
|
||||
async def go():
|
||||
hass = FakeHass(meter, soc_dies_at)
|
||||
c = Controller(dict(BASE, cycle_floor_s=floor, **over), hass, _Store(),
|
||||
_Pub(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
stamps = []
|
||||
real = c.cycle
|
||||
|
||||
async def counted():
|
||||
stamps.append(time.monotonic() - hass.t0)
|
||||
await real()
|
||||
|
||||
c.cycle = counted
|
||||
task = asyncio.create_task(c.run_control())
|
||||
await asyncio.sleep(seconds)
|
||||
c.stopping = True
|
||||
await asyncio.wait_for(task, timeout=10)
|
||||
return stamps, hass.writes, c.target, c.reason
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
def worst_gap(stamps, seconds):
|
||||
"""Longest stretch with no cycle, including the tail after the last one."""
|
||||
edges = [0.0] + list(stamps) + [seconds]
|
||||
return max(b - a for a, b in zip(edges, edges[1:]))
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter that repeats the same value")
|
||||
FLAT = lambda t: 350.0 # noqa: E731
|
||||
FLOOR, SECONDS = 3.0, 12.0
|
||||
|
||||
pre_stamps, pre_writes, _, _ = drive(FLAT, NEVER, SECONDS)
|
||||
# The defect itself, demonstrated rather than described: one cycle at startup
|
||||
# and then nothing for the rest of the window, while writes keep happening.
|
||||
check("pre-fix: a constant meter runs exactly one cycle, at startup",
|
||||
len(pre_stamps) == 1)
|
||||
check("...while the heartbeat keeps writing anyway, so nothing looks wrong",
|
||||
len(pre_writes) >= 2)
|
||||
|
||||
post_stamps, post_writes, _, _ = drive(FLAT, FLOOR, SECONDS)
|
||||
check("post-fix: the same constant meter runs cycles throughout",
|
||||
len(post_stamps) >= int(SECONDS / FLOOR) - 1)
|
||||
# The actual acceptance criterion: a BOUND on the gap, not a count.
|
||||
gap = worst_gap(post_stamps, SECONDS)
|
||||
check(f"...with no gap longer than the floor ({gap:.1f}s <= {FLOOR + 1.5:.1f}s)",
|
||||
gap <= FLOOR + 1.5)
|
||||
check("...and the loop actually corrected, instead of holding a stale command",
|
||||
len(post_writes) > len(pre_writes))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter that changes normally - nothing may move")
|
||||
# ⚠️ THE REGRESSION GUARD, and the more important half. The floor is a deadline
|
||||
# on the gap between cycles, reset by every cycle whichever trigger fired - not
|
||||
# a second scheduler. On a healthy meter it must never elapse, so the cycle
|
||||
# count, the write count and the commanded values must be IDENTICAL either side
|
||||
# of the fix. Anything else is a new write cadence, which SAFETY-12 forbids:
|
||||
# the deadband, step_w and the 10 s force-write decide what reaches the wire,
|
||||
# and this change is only allowed to alter when the loop thinks.
|
||||
STEPS = [0.0, 300.0, 850.0, -400.0, 120.0, -900.0, 60.0]
|
||||
LIVE = lambda t: STEPS[int(t // 2) % len(STEPS)] # noqa: E731
|
||||
|
||||
a_stamps, a_writes, _, _ = drive(LIVE, NEVER, 12.0)
|
||||
b_stamps, b_writes, _, _ = drive(LIVE, FLOOR, 12.0)
|
||||
check("a changing meter runs the same number of cycles as before the fix",
|
||||
len(a_stamps) == len(b_stamps))
|
||||
check("...commanding exactly the same sequence of values", a_writes == b_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("a meter parked at the target - the converged operating point")
|
||||
# The case TEL-05 warned about: at the converged target the power figure
|
||||
# legitimately repeats for minutes. The loop must still run, and must still
|
||||
# write nothing but the heartbeat, because the deadband - not the arrival
|
||||
# trigger - is what holds the command still.
|
||||
AT_TARGET = lambda t: -10.0 # noqa: E731
|
||||
c_stamps, c_writes, _, _ = drive(AT_TARGET, NEVER, 12.0)
|
||||
d_stamps, d_writes, _, _ = drive(AT_TARGET, FLOOR, 12.0)
|
||||
check("the loop evaluates at the converged point too", len(d_stamps) > len(c_stamps))
|
||||
check("...and the deadband still holds the command, so writes are unchanged",
|
||||
d_writes == c_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("an input dies while the meter repeats - the safety claim must still fire")
|
||||
# ⚠️ THE STRONGEST PROPERTY IN SAFETY-12, and the one that makes it a safety fix
|
||||
# rather than a latency fix. The `inputs missing -> 0 W` claim lives INSIDE
|
||||
# cycle() (main.py, the stale_input_s branch and the P_SAFETY claim below it).
|
||||
# Pre-fix, on a meter whose value happened to repeat, cycle() was never called
|
||||
# again - so that claim could not fire AT ALL. The controller held its last
|
||||
# command through an input outage of unbounded length with the status line still
|
||||
# reading "loop -> N W".
|
||||
#
|
||||
# Layer 1 does not cover this either on a `meter_source: off` install: no P1 age
|
||||
# sensor is published (see Controller.publish), so the firmware has nothing to
|
||||
# veto on, and the heartbeat keeps its watchdog fed the whole time.
|
||||
#
|
||||
# stale_input_s is shortened to 3 s here so the outage resolves inside a test
|
||||
# rather than inside a quarter of a minute. The mechanism is the default one.
|
||||
c2_stamps, c2_writes, pre_target, pre_reason = drive(
|
||||
FLAT, NEVER, 10.0, soc_dies_at=4.0, stale_input_s=3)
|
||||
check("pre-fix: a dead input during a constant meter never reaches the safety claim",
|
||||
pre_target != 0.0 and "safety" not in pre_reason)
|
||||
check(f"...so it holds its last command instead ({pre_target:g} W, {pre_reason!r})",
|
||||
pre_target == 220.0)
|
||||
|
||||
d2_stamps, d2_writes, post_target, post_reason = drive(
|
||||
FLAT, FLOOR, 10.0, soc_dies_at=4.0, stale_input_s=3)
|
||||
check("post-fix: the same outage commands 0 W", post_target == 0.0)
|
||||
check(f"...through the safety claim, not by accident ({post_reason!r})",
|
||||
"safety" in post_reason)
|
||||
check("...and the 0 W actually reached the device", 0.0 in d2_writes)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + "; ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -26,9 +26,15 @@ def check(name, cond):
|
||||
|
||||
def base(**over):
|
||||
"""A configuration that must start. Everything else is this, spoilt."""
|
||||
# ⚠️ The maintenance rates are named EXPLICITLY, at the values config.yaml
|
||||
# ships (MAINT-04). They are not decoration: with the key absent, rule 6
|
||||
# falls back to main.py's 2500 W, which against this 2000 W ceiling is a
|
||||
# genuine refusal - so a base() without them would be a config that does
|
||||
# not start, and every check below would be measuring the wrong thing.
|
||||
o = {"setpoint_entity": "number.goodwe_setpoint", "max_w": 2000,
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off"}
|
||||
"meter_source": "off",
|
||||
"maintenance_charge_w": 2000, "maintenance_discharge_w": 2000}
|
||||
o.update(over)
|
||||
return o
|
||||
|
||||
@@ -151,6 +157,170 @@ check("with meter_source off the number governs nothing and is not refused",
|
||||
check("the constant is the firmware's, not a rounded guess",
|
||||
FIRMWARE_INGEST_VETO_S == 30.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("6. a maintenance charge the ceiling can actually accommodate (MAINT-04)")
|
||||
# ⚠️ THE SHIPPED BUG. config.yaml shipped max_w 2000 against
|
||||
# maintenance_charge_w 2500, so the cheap-window shaping asked for hi=-2500
|
||||
# against the supervised lo=-2000 - lo > hi, arbiter clause 3, 0 W. Maintenance
|
||||
# silently never charged in a cheap window on a default install.
|
||||
p = validate_startup_config(base(max_w=2000, maintenance_charge_w=2500),
|
||||
-5000, 5000)
|
||||
check("maintenance_charge_w above max_w is refused", len(p) == 1)
|
||||
check("...and the message names the charge rate", why(p, "2500"))
|
||||
check("...and the ceiling", why(p, "2000"))
|
||||
check("...and says which one wins", why(p, "THE CEILING WINS"))
|
||||
# ⚠️ Equality is REACHABLE, not a near miss: lo=-2000, hi=-2000 is the single
|
||||
# point -2000 W. Refusing it would be exactly the trivia that gets a validator
|
||||
# deleted, and it is the boundary the rule is written `>` for.
|
||||
check("maintenance_charge_w exactly at max_w starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_charge_w=2000),
|
||||
-5000, 5000) == [])
|
||||
check("below it starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_charge_w=1500),
|
||||
-5000, 5000) == [])
|
||||
# Not scoped to maintenance_enabled: the pair is contradictory either way, and
|
||||
# scoping would leave the trap armed for the one action - ticking the box - that
|
||||
# cannot be expected to change what a charge rate means.
|
||||
check("...and it is refused with maintenance_enabled off, as shipped",
|
||||
why(validate_startup_config(
|
||||
base(max_w=2000, maintenance_charge_w=2500,
|
||||
maintenance_enabled=False), -5000, 5000), "THE CEILING WINS"))
|
||||
|
||||
# ⚠️ THE SIBLING, CHECKED RATHER THAN ASSUMED. The shaping is NOT symmetric:
|
||||
# drain files Claim.set at P_MAINTENANCE and owns the actuator, so the ceiling
|
||||
# CLAMPS it (+2000 W) instead of contradicting it, and the arbiter's explain()
|
||||
# names the clamp every cycle. Loud, and it still moves energy - so warned, not
|
||||
# refused. If someone later "fixes the asymmetry" by making this a refusal,
|
||||
# this check goes red and they have to justify it.
|
||||
check("maintenance_discharge_w above max_w WARNS but starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_discharge_w=2500),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# The demonstration the rule is derived from, asserted rather than described.
|
||||
from app.arbiter import ( # noqa: E402
|
||||
Claim, P_LOOP, P_MAINTENANCE, P_MAINT_SHAPE, P_SAFETY, resolve,
|
||||
)
|
||||
|
||||
def _charge(max_w, charge_w):
|
||||
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-charge_w,
|
||||
reason="cheap-window charge"),
|
||||
Claim.set("loop", P_LOOP, 500.0, "grid")])
|
||||
|
||||
def _drain(max_w, disch_w):
|
||||
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
|
||||
Claim.set("maintenance", P_MAINTENANCE, disch_w, "drain"),
|
||||
Claim.set("loop", P_LOOP, 500.0, "grid")])
|
||||
|
||||
r = _charge(2000, 2500)
|
||||
check("arbiter: the refused pair really does emit 0 W",
|
||||
r.target_w == 0.0 and r.contradiction)
|
||||
r = _charge(2000, 2000)
|
||||
check("arbiter: the permitted equality really does charge",
|
||||
r.target_w == -2000.0 and not r.contradiction)
|
||||
r = _charge(3000, 2500)
|
||||
check("arbiter: raising max_w above the rate charges at the rate",
|
||||
r.target_w == -2500.0 and not r.contradiction)
|
||||
r = _drain(2000, 2500)
|
||||
check("arbiter: the drain SET is clamped, not contradicted",
|
||||
r.target_w == 2000.0 and not r.contradiction)
|
||||
check("...and the clamp names itself, which is why it is not refused",
|
||||
"supervised" in (r.bound_by or "") and "limited by" in r.explain())
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the SHIPPED defaults must pass the rule they are governed by (AC3)")
|
||||
# ⚠️ Shipping a default the validator refuses would be worse than the bug it
|
||||
# refuses. Read config.yaml itself rather than a transcription of it - a
|
||||
# transcription is what lets the two drift apart silently. Regex, not PyYAML:
|
||||
# the add-on image has no PyYAML (Dockerfile installs py3-aiohttp/py3-paho-mqtt
|
||||
# only) and a check that skips on ImportError is not a check.
|
||||
import os # noqa: E402
|
||||
import re # noqa: E402
|
||||
|
||||
_CFG = os.path.join(os.path.dirname(os.path.abspath(__file__)), "config.yaml")
|
||||
with open(_CFG, encoding="utf-8") as _fh:
|
||||
_txt = _fh.read()
|
||||
_shipped = {k: float(v) for k, v in re.findall(
|
||||
r"^ (max_w|maintenance_charge_w|maintenance_discharge_w|sign_disagree_w): "
|
||||
r"(-?\d+(?:\.\d+)?)\s*$", _txt, re.M)}
|
||||
check("config.yaml really was read (all four defaults found)",
|
||||
set(_shipped) == {"max_w", "maintenance_charge_w",
|
||||
"maintenance_discharge_w", "sign_disagree_w"})
|
||||
check(f"the shipped defaults are accepted {_shipped}",
|
||||
validate_startup_config(base(**_shipped), -5000, 5000) == [])
|
||||
check("...and the shipped charge rate is at or under the shipped ceiling",
|
||||
_shipped["maintenance_charge_w"] <= _shipped["max_w"])
|
||||
check("...and the shipped discharge rate too, so it warns about nothing",
|
||||
_shipped["maintenance_discharge_w"] <= _shipped["max_w"])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the KNOWN cross-file default divergence, pinned rather than commented")
|
||||
# ⚠️ WHAT THIS GUARDS, AND WHY IT ASSERTS THE BUG RATHER THAN THE FIX.
|
||||
# config.yaml and validate.py now default maintenance_charge_w to 2000, while
|
||||
# main.py's two `opts.get(..., 2500)` fallbacks and MaintConfig's dataclass
|
||||
# default still say 2500. So an options dict with the key ABSENT is ACCEPTED by
|
||||
# rule 6 at 2000 and then built by main.py at 2500 - which is a contradiction:
|
||||
#
|
||||
# validate_startup_config -> [] (accepted)
|
||||
# MaintConfig().charge_w -> 2500.0
|
||||
# arbiter -> 0.0 W, contradiction=True
|
||||
#
|
||||
# That is the bug rule 6 exists to catch, passing rule 6. It is unreachable on a
|
||||
# Supervisor install (every key is always supplied from config.yaml) but fully
|
||||
# reachable from sim/inject.py and from tests - which is exactly where anyone
|
||||
# debugging maintenance works.
|
||||
#
|
||||
# The fix is ONE SOURCE OF TRUTH for option defaults. That is a bigger change
|
||||
# than this ticket and it lands in main.py, which another ticket is live in - so
|
||||
# the divergence is RECORDED here instead of closed. The check therefore passes
|
||||
# on the mismatch and FAILS when either side moves, in EITHER direction:
|
||||
#
|
||||
# - config.yaml moves -> FAIL: re-decide what the fallback should be
|
||||
# - main.py is fixed to match -> FAIL: the divergence is gone, DELETE this
|
||||
# check and the ⚠️ block in validate.py
|
||||
#
|
||||
# A comment cannot do that, and "a comment where a check belonged" is this
|
||||
# repo's most repeated defect.
|
||||
_APP = os.path.join(os.path.dirname(os.path.abspath(__file__)), "app")
|
||||
|
||||
def _read(*parts):
|
||||
with open(os.path.join(*parts), encoding="utf-8") as fh:
|
||||
return fh.read()
|
||||
|
||||
# Every literal fallback for this key in main.py, whatever the call shape.
|
||||
_main_falls = [float(m) for m in re.findall(
|
||||
r'\.get\(\s*"maintenance_charge_w"\s*,\s*(-?\d+(?:\.\d+)?)\s*\)',
|
||||
_read(_APP, "main.py"))]
|
||||
# ...and MaintConfig's own dataclass default, which is the one that bites when
|
||||
# main.py is bypassed entirely (a Maintenance built straight from defaults).
|
||||
_dc_falls = [float(m) for m in re.findall(
|
||||
r"^\s*charge_w:\s*float\s*=\s*(-?\d+(?:\.\d+)?)\s*$",
|
||||
_read(_APP, "maintenance.py"), re.M)]
|
||||
|
||||
check(f"main.py's fallbacks are still found and still 2500 {_main_falls}",
|
||||
len(_main_falls) == 2 and set(_main_falls) == {2500.0})
|
||||
check(f"MaintConfig's default is still found and still 2500 {_dc_falls}",
|
||||
len(_dc_falls) == 1 and set(_dc_falls) == {2500.0})
|
||||
check(f"...and config.yaml still ships 2000, so the divergence is UNCHANGED "
|
||||
f"(shipped {_shipped['maintenance_charge_w']:.0f}, code 2500)",
|
||||
_shipped["maintenance_charge_w"] == 2000.0)
|
||||
|
||||
# ⚠️ And the consequence itself, through the REAL code rather than through the
|
||||
# numbers above - so that if someone "fixes" this by changing a literal without
|
||||
# understanding it, the thing that goes red is the behaviour, not the transcript.
|
||||
from app.maintenance import MaintConfig # noqa: E402
|
||||
|
||||
_absent = {k: v for k, v in base().items() if k != "maintenance_charge_w"}
|
||||
_built = MaintConfig().charge_w
|
||||
check("with the key ABSENT the validator accepts...",
|
||||
validate_startup_config(_absent, -5000, 5000) == [])
|
||||
check(f"...while the code would build {_built:.0f} W against a "
|
||||
f"{_absent['max_w']:.0f} W ceiling...", _built > _absent["max_w"])
|
||||
_r = _charge(_absent["max_w"], _built)
|
||||
check("...which the arbiter resolves to 0 W as a contradiction - the hole, "
|
||||
"asserted so it cannot widen unnoticed",
|
||||
_r.target_w == 0.0 and _r.contradiction)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("max_w must be a positive magnitude")
|
||||
# Schema-blocked on a real install, but validate_startup_config() is also
|
||||
@@ -160,8 +330,18 @@ for bad in (0, -1, -2000):
|
||||
check(f"max_w {bad} is refused", len(p) == 1 and why(p, "must be positive"))
|
||||
check("...and the message explains it would read as a trip, not a mistake",
|
||||
why(validate_startup_config(base(max_w=0), -5000, 5000), "contradiction"))
|
||||
# ⚠️ SAFETY-02 changed what this case has to say, and the change is real rather
|
||||
# than bookkeeping: with a 1 W ceiling the default 300 W sign-disagreement
|
||||
# threshold is unreachable, so rule 5 refuses - correctly, because the watchdog
|
||||
# would report itself armed while being incapable of firing. What this check is
|
||||
# FOR is "a positive max_w is not itself a refusal", so it now names a sign
|
||||
# threshold the ceiling can actually reach, and the interaction gets its own
|
||||
# check below.
|
||||
check("the smallest sane max_w still starts",
|
||||
validate_startup_config(base(max_w=1), -5000, 5000) == [])
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000) == [])
|
||||
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
|
||||
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("what must NOT be refused - a validator that fires on trivia gets deleted")
|
||||
|
||||
@@ -0,0 +1,495 @@
|
||||
"""Runnable check for the sign-disagreement watchdog. `python3 test_watchdog.py`
|
||||
|
||||
Every case here is either a fault this must catch or a piece of NORMAL behaviour
|
||||
it must not mistake for one. The second list is the longer one on purpose: an
|
||||
alarm that fires on ordinary operation is worse than no alarm, because the next
|
||||
person switches it off.
|
||||
|
||||
The headline validation is not here - it is `sim/replay_sign.py` in the infra
|
||||
repo, which drives this module over the two captured bus days. This file is the
|
||||
table-driven half: boundaries, timers, the latch, and the arming gate.
|
||||
"""
|
||||
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.watchdog import (
|
||||
SignWatchdog, SignWatchdogConfig, loop_is_following,
|
||||
)
|
||||
|
||||
fails = []
|
||||
T0 = datetime(2026, 8, 20, 15, 0, 0, tzinfo=timezone.utc)
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def drive(samples, cfg=None, following=True):
|
||||
"""Feed (offset_s, commanded_w, grid_w) tuples. Returns (wd, trip_offset)."""
|
||||
wd = SignWatchdog(cfg)
|
||||
trip_at = None
|
||||
for item in samples:
|
||||
offset, cmd, grid = item[0], item[1], item[2]
|
||||
f = item[3] if len(item) > 3 else following
|
||||
if wd.evaluate(cmd, grid, f, T0 + timedelta(seconds=offset)) and trip_at is None:
|
||||
trip_at = offset
|
||||
return wd, trip_at
|
||||
|
||||
|
||||
def opposed(duration_s, step=5, cmd=-1000, grid=1500, following=True, start=0):
|
||||
return [(start + t, cmd, grid, following)
|
||||
for t in range(0, int(duration_s) + 1, step)]
|
||||
|
||||
|
||||
print("the fault it exists to catch")
|
||||
wd, at = drive(opposed(300))
|
||||
check("charging into an importing house trips", wd.tripped)
|
||||
check("and trips at 180 s, not before", at == 180)
|
||||
check("the reason names both signals", "-1000" in wd.reason and "+1500" in wd.reason)
|
||||
print(f" e.g. {wd.reason!r}")
|
||||
|
||||
wd, at = drive(opposed(300, cmd=2000, grid=-2000))
|
||||
check("discharging into an exporting house trips too", wd.tripped and at == 180)
|
||||
|
||||
print()
|
||||
print("the boundaries")
|
||||
wd, _ = drive(opposed(600, cmd=-300, grid=1500))
|
||||
check("300 W exactly does NOT qualify (strictly greater)", not wd.tripped)
|
||||
wd, _ = drive(opposed(600, cmd=-301, grid=1500))
|
||||
check("301 W does", wd.tripped)
|
||||
wd, _ = drive(opposed(600, cmd=-1000, grid=300))
|
||||
check("a 300 W meter does not qualify either", not wd.tripped)
|
||||
wd, _ = drive(opposed(175))
|
||||
check("175 s of disagreement does not trip", not wd.tripped)
|
||||
wd, _ = drive(opposed(180))
|
||||
check("180 s does (>= hold_s)", wd.tripped)
|
||||
|
||||
print()
|
||||
print("continuity - the rule that produced zero false positives on real data")
|
||||
broken = opposed(175) + [(180, -1000, -1500)] + opposed(175, start=185)
|
||||
wd, _ = drive(broken)
|
||||
check("179 s, one agreeing sample, then 175 s more: no trip", not wd.tripped)
|
||||
check("and the window really was reset", wd.disagree_since is not None)
|
||||
long_enough = broken + opposed(200, start=365)
|
||||
wd, _ = drive(long_enough)
|
||||
check("but a full 180 s after the reset does trip", wd.tripped)
|
||||
|
||||
print()
|
||||
print("things that are NOT faults")
|
||||
# The load-step transient. Measured on the healthy capture: longest 30 s.
|
||||
wd, _ = drive(opposed(30) + [(35 + t, 800, 900) for t in range(0, 300, 5)])
|
||||
check("a 30 s load-step crossover does not trip", not wd.tripped)
|
||||
|
||||
# SoC 10 %, Standby, declining a 1350 W discharge. The battery does nothing, so
|
||||
# the meter stays where it was and the command agrees with it.
|
||||
wd, _ = drive([(t, 1350, 1350) for t in range(0, 900, 5)])
|
||||
check("a battery refusing a discharge command cannot trip it", not wd.tripped)
|
||||
|
||||
# A frozen meter drives command and reading into agreement, not disagreement.
|
||||
wd, _ = drive([(t, 800, 800) for t in range(0, 900, 5)])
|
||||
check("a frozen meter cannot trip it", not wd.tripped)
|
||||
|
||||
# Maintenance grid charge: 2500 W of charge against an importing house, for
|
||||
# hours. Opposed, both huge - and entirely correct.
|
||||
wd, _ = drive(opposed(7200, cmd=-2500, grid=3000, following=False))
|
||||
check("two hours of maintenance grid charge does not trip", not wd.tripped)
|
||||
check("and the timer never even started", wd.disagree_since is None)
|
||||
|
||||
wd, _ = drive([(t, -1000, None) for t in range(0, 900, 5)])
|
||||
check("a missing meter reading does not trip", not wd.tripped)
|
||||
wd, _ = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
|
||||
check("a missing reading mid-window RESETS it rather than accumulating",
|
||||
wd.tripped and wd.disagree_since is not None)
|
||||
wd, at = drive(opposed(175) + [(180, -1000, None)] + opposed(600, start=185))
|
||||
check("...so the trip lands 180 s after the gap, not after 180 s total",
|
||||
at == 365)
|
||||
|
||||
wd, _ = drive([(t, 0.0, 3000) for t in range(0, 900, 5)])
|
||||
check("a 0 W command is not a wrong-direction command", not wd.tripped)
|
||||
|
||||
print()
|
||||
print("the latch")
|
||||
wd, _ = drive(opposed(200))
|
||||
check("tripped after the fault", wd.tripped)
|
||||
# The trip commands 0 W, which removes the command side of the comparison.
|
||||
for t in range(200, 900, 5):
|
||||
wd.evaluate(0.0, 3000, True, T0 + timedelta(seconds=t))
|
||||
check("stays tripped once the command is zeroed", wd.tripped)
|
||||
for t in range(900, 1500, 5):
|
||||
wd.evaluate(1000, 1000, True, T0 + timedelta(seconds=t))
|
||||
check("stays tripped even once everything looks healthy again", wd.tripped)
|
||||
wd.reset()
|
||||
check("reset() is the only way out", not wd.tripped and wd.disagree_since is None)
|
||||
check("and the reason is cleared with it", wd.reason == "")
|
||||
|
||||
print()
|
||||
print("the thresholds are configuration, not constants")
|
||||
cfg = SignWatchdogConfig(min_w=800.0, hold_s=60.0)
|
||||
wd, at = drive(opposed(300, cmd=-1000, grid=1500), cfg=cfg)
|
||||
check("a 60 s hold trips at 60 s", wd.tripped and at == 60)
|
||||
wd, _ = drive(opposed(600, cmd=-700, grid=1500), cfg=cfg)
|
||||
check("an 800 W gate ignores a 700 W command", not wd.tripped)
|
||||
|
||||
print()
|
||||
print("the configuration that would disarm it is refused")
|
||||
from app.validate import validate_startup_config # noqa: E402
|
||||
|
||||
base = {"setpoint_entity": "number.sp", "meter_source": "off",
|
||||
"meter_phases": 1, "meter_max_age_s": 30}
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 300},
|
||||
-5000, 5000)
|
||||
check("300 W under a 2000 W ceiling is accepted", p == [])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 2000},
|
||||
-5000, 5000)
|
||||
check("a threshold AT max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
# ⚠️ maintenance_charge_w is named here only to keep this case about the SIGN
|
||||
# rule. MAINT-04 added a second rule against the same ceiling, and a 500 W
|
||||
# max_w is also below the 2000 W shipped maintenance charge - so without this
|
||||
# the dict is refused twice, for two correct but different reasons, and the
|
||||
# `len(p) == 1` below would be measuring the interaction rather than this rule.
|
||||
p = validate_startup_config({**base, "max_w": 500, "sign_disagree_w": 3000,
|
||||
"maintenance_charge_w": 500}, -5000, 5000)
|
||||
check("a threshold above max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 1999},
|
||||
-5000, 5000)
|
||||
check("one watt under the ceiling is reachable, so accepted", p == [])
|
||||
|
||||
print()
|
||||
print("the arming gate, derived from the REAL arbiter")
|
||||
# ⚠️ THIS IS THE DECISION THE WHOLE TICKET TURNS ON, and until now it was
|
||||
# asserted in three comment blocks and verified by nothing: every other case in
|
||||
# this file passes `following` in as a literal. What has to hold is that the
|
||||
# expression in main.py - loop won AND the emitted value points the way the loop
|
||||
# asked AND is no larger - is never True for a resolution the loop did not
|
||||
# actually get. So run real claims through the real resolve() and derive it.
|
||||
from app.arbiter import ( # noqa: E402
|
||||
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY, Claim, resolve,
|
||||
)
|
||||
|
||||
|
||||
def following_from(claims, asked):
|
||||
"""THE SHIPPED gate, not a copy of it.
|
||||
|
||||
⚠️ This used to transcribe main.py's expression with a comment saying
|
||||
"keep the two in step", which is exactly the arrangement that does not keep
|
||||
two things in step. Measured: editing the shipped gate alone to
|
||||
`winner in ("loop", "peak")` left this suite - including the P_PEAK row below,
|
||||
whose entire job is to catch that edit - completely green, while the watchdog
|
||||
went blind for the duration of every peak event. Import it or the P_PEAK
|
||||
assertion is decoration.
|
||||
"""
|
||||
r = resolve(claims)
|
||||
return r, loop_is_following(r, asked)
|
||||
|
||||
|
||||
MAXW = Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w")
|
||||
DEV = Claim.limit("device", P_SAFETY, -5000, 5000, "rating")
|
||||
|
||||
# name, claims, what the loop asked, expected `following`
|
||||
TABLE = [
|
||||
("the loop alone, unopposed",
|
||||
[Claim.set("loop", P_LOOP, 900)], 900, True),
|
||||
("the loop bound by max_w - reduced, not redirected",
|
||||
[Claim.set("loop", P_LOOP, 4000), MAXW], 4000, True),
|
||||
("charging, bound by max_w on the other side",
|
||||
[Claim.set("loop", P_LOOP, -4000), MAXW], -4000, True),
|
||||
("maintenance owns the setpoint outright",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("maintenance", P_MAINTENANCE, -2500, "charge"), MAXW], 900, False),
|
||||
("maintenance charge-only clamps the loop to 0 W",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only"),
|
||||
MAXW], 900, False),
|
||||
# ⚠️ THE CASE `winner == \"loop\"` ALONE WOULD HAVE GOT WRONG. 1500 W, not
|
||||
# the default 2500 W: at max_w 2000 a -2500 hi against a -2000 lo is an
|
||||
# arbiter contradiction, not a charge - see main.py.
|
||||
("cheap-window charge REDIRECTS the loop while it still 'wins'",
|
||||
[Claim.set("loop", P_LOOP, 500),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-1500, reason="cheap-window"),
|
||||
MAXW], 500, False),
|
||||
("...and the contradiction at the shipped defaults is not following either",
|
||||
[Claim.set("loop", P_LOOP, 500),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-2500, reason="cheap-window"),
|
||||
MAXW], 500, False),
|
||||
("a lo limit RAISES the magnitude without flipping the sign",
|
||||
[Claim.set("loop", P_LOOP, 200),
|
||||
Claim.limit("floor", P_SAFETY, lo=800), MAXW], 200, False),
|
||||
("a safety stop wins outright",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("safety", P_SAFETY, 0.0, "stopped"), MAXW], 900, False),
|
||||
("no claims at all - the arbiter's own failsafe",
|
||||
[MAXW, DEV], None, False),
|
||||
("the loop asked for zero",
|
||||
[Claim.set("loop", P_LOOP, 0.0), MAXW], 0.0, False),
|
||||
# The forward hazard, asserted as it stands TODAY rather than as it should
|
||||
# be. When peak shaving lands, these expectations are what have to change.
|
||||
("peak shaving at P_PEAK disarms the gate (loop_is_following's forward hazard)",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("peak", P_PEAK, 1800, "shaving"), MAXW], 900, False),
|
||||
# ⚠️ AND THE ROW ABOVE CANNOT DETECT A WIDENED GATE ON ITS OWN, which was
|
||||
# found by trying it: with the shipped gate edited to
|
||||
# `winner in ("loop", "peak")` that case STILL comes out False, because peak
|
||||
# shaving asked for MORE than the loop and the magnitude term rejects it
|
||||
# anyway. The winner term is masked. This row isolates it - a peak claim
|
||||
# smaller than the loop's ask and pointing the same way, so `winner` is the
|
||||
# only term that can decide - and it is what actually turns red if the gate
|
||||
# is widened without anyone revisiting the hazard.
|
||||
("...and with peak BELOW the loop's ask, only the winner term separates them",
|
||||
[Claim.set("loop", P_LOOP, 1800),
|
||||
Claim.set("peak", P_PEAK, 900, "shaving"), MAXW], 1800, False),
|
||||
]
|
||||
for name, claims, asked, expect in TABLE:
|
||||
r, got = following_from(claims, asked)
|
||||
check(f"{name} -> following={expect}", got is expect)
|
||||
if got is not expect:
|
||||
print(f" resolution was {r.explain()!r}")
|
||||
|
||||
# And the gate is never True when the loop did not win, whatever else is going on.
|
||||
check("no configuration above arms the gate without the loop winning",
|
||||
all(not following_from(c, a)[1]
|
||||
for _, c, a, _ in TABLE if following_from(c, a)[0].winner != "loop"))
|
||||
|
||||
print()
|
||||
print("end to end: the trip is COMMAND ZERO, not alarm-only")
|
||||
# ⚠️ THE FAULT INJECTED HERE IS A NEGATIVE GAIN, and that is not a contrivance -
|
||||
# it is the minimal faithful model of what this watchdog is for. The check
|
||||
# compares the loop's OUTPUT DIRECTION against the INPUT STATE it was regulating,
|
||||
# so what it detects is a loop whose two ends have become decoupled in sign: a
|
||||
# gain, a claim or a strategy with its polarity inverted, or an integrator so far
|
||||
# wound up that unwinding takes minutes. (Illusmart's was the last one: it
|
||||
# reached -14 768 W against a +-5000 W rail while writing once every 20-60 s, and
|
||||
# that arithmetic alone is 5-15 minutes of wrong-direction command.)
|
||||
#
|
||||
# `gain` is float(0.05,1.0) in the schema, so this is not a reachable
|
||||
# configuration - it is a stand-in for a code regression, which is the case a
|
||||
# unit test can actually hold the line on.
|
||||
import asyncio # noqa: E402
|
||||
|
||||
from app.main import Controller # noqa: E402
|
||||
|
||||
|
||||
class _Hass:
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
# A house importing 2000 W, steadily, whatever the battery does.
|
||||
return {"sensor.grid": 2000.0, "sensor.soc": 50.0,
|
||||
"sensor.batt": 0.0}.get(entity)
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
return True
|
||||
|
||||
|
||||
class _S:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _P:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
async def _e2e():
|
||||
hass = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
c = Controller(opts, hass, _S(), _P(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
seen_wrong_way = False
|
||||
for _ in range(12):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
if c.target < -300 and not c.sign_wd.tripped:
|
||||
seen_wrong_way = True
|
||||
await asyncio.sleep(0.25)
|
||||
return c, hass, seen_wrong_way
|
||||
|
||||
|
||||
ctrl, hass, wrong_way = asyncio.run(_e2e())
|
||||
check("the broken loop really did command charge into an import first", wrong_way)
|
||||
check("the watchdog tripped", ctrl.sign_wd.tripped)
|
||||
check("the commanded value is 0 W", ctrl.target == 0.0)
|
||||
check("0 W actually reached the device", 0.0 in hass.writes)
|
||||
check("and it got there through the failsafe claim, not by accident",
|
||||
"failsafe" in ctrl.reason)
|
||||
print(f" status line: {ctrl.reason!r}")
|
||||
check("the status page says so in words",
|
||||
any("SIGN-DISAGREEMENT FAILSAFE" in c["text"] for c in ctrl.checks()))
|
||||
check("the banner leads with it",
|
||||
"FAILSAFE" in ctrl.status_payload()["banner"])
|
||||
check("it stays at 0 W on later cycles too",
|
||||
hass.writes[-1] == 0.0 and hass.writes.count(0.0) >= 1)
|
||||
|
||||
# ⚠️ THIS USED TO BE `check("MQTT reports the failsafe state", ctrl.sign_wd.tripped)`
|
||||
# which restates the assertion three lines above and never touches the payload.
|
||||
# The `status: "failsafe"` value was shipped untested. Capture what publish()
|
||||
# actually hands the broker.
|
||||
published = {}
|
||||
ctrl.mqtt = type("P", (), {"enabled": True,
|
||||
"publish": lambda _s, v: published.update(v),
|
||||
"close": lambda _s: None})()
|
||||
ctrl.publish()
|
||||
check("MQTT's controller-status sensor reports 'failsafe'",
|
||||
published.get("status") == "failsafe")
|
||||
ctrl.sign_wd.reset()
|
||||
ctrl.publish()
|
||||
check("...and goes back to 'running' once cleared",
|
||||
published.get("status") == "running")
|
||||
|
||||
|
||||
print()
|
||||
print("the latch survives a restart - it is the only thing between a tripped")
|
||||
print("controller and the first thing an operator will try")
|
||||
# ⚠️ THE BLOCKER THIS FILE MISSED FIRST TIME ROUND. `auto` is persisted and
|
||||
# `tripped` was not, so reconstructing a Controller against the same Store -
|
||||
# which is exactly what a container restart does - came back armed, into the
|
||||
# fault, with no operator involved: tripped=False, banner NOT READY, and it
|
||||
# resumed commanding -1000 then -2000 W before re-tripping 180 s later.
|
||||
|
||||
|
||||
class _MemStore:
|
||||
"""A Store that keeps its dict across "restarts", like the real file does."""
|
||||
|
||||
def __init__(self):
|
||||
self.data = {"phase": "idle", "sign_tripped": False, "sign_reason": ""}
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
async def _restart():
|
||||
shared = _MemStore()
|
||||
hass1 = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
a = Controller(opts, hass1, shared, _P(), stop=asyncio.Event())
|
||||
a.auto = True
|
||||
a.dev_min, a.dev_max = -5000.0, 5000.0
|
||||
for _ in range(12):
|
||||
await a.read_inputs()
|
||||
await a.cycle()
|
||||
await asyncio.sleep(0.25)
|
||||
|
||||
# The restart. Same options, same store, brand new Controller and Hass.
|
||||
hass2 = _Hass()
|
||||
b = Controller(opts, hass2, shared, _P(), stop=asyncio.Event())
|
||||
b.auto = True
|
||||
b.dev_min, b.dev_max = -5000.0, 5000.0
|
||||
for _ in range(6):
|
||||
await b.read_inputs()
|
||||
await b.cycle()
|
||||
await asyncio.sleep(0.05)
|
||||
return a, b, shared, hass2
|
||||
|
||||
|
||||
pre, post, store, hass2 = asyncio.run(_restart())
|
||||
check("it tripped before the restart", pre.sign_wd.tripped)
|
||||
check("the trip reached the store", store.data["sign_tripped"] is True)
|
||||
check("...with the reason beside it, so the operator is told why",
|
||||
"SIGN_DISAGREEMENT" in store.data["sign_reason"])
|
||||
check("the new Controller comes back TRIPPED", post.sign_wd.tripped)
|
||||
check("...and says why, restored rather than re-detected",
|
||||
"SIGN_DISAGREEMENT" in post.sign_wd.reason)
|
||||
check("...commands 0 W from its very first cycle", post.target == 0.0)
|
||||
check("...and never commanded anything else after the restart",
|
||||
hass2.writes != [] and set(hass2.writes) == {0.0})
|
||||
check("the banner still leads with the failsafe",
|
||||
"FAILSAFE" in post.status_payload()["banner"])
|
||||
# ⚠️ TWO PRESSES, and the first one must NOT clear it. `auto` is True while
|
||||
# tripped, so the first press stops control; only the transition back to True
|
||||
# clears. That is the documented behaviour and it is worth an assertion, because
|
||||
# a one-press clear would be reachable by an operator who never read the banner.
|
||||
asyncio.run(post.handle_action("auto_toggle")) # -> stopped
|
||||
check("pressing stop does not clear the failsafe",
|
||||
post.sign_wd.tripped and store.data["sign_tripped"] is True)
|
||||
asyncio.run(post.handle_action("auto_toggle")) # -> started
|
||||
check("pressing start DOES clear it, and clears the store with it",
|
||||
not post.sign_wd.tripped and store.data["sign_tripped"] is False
|
||||
and store.data["sign_reason"] == "")
|
||||
# One more restart from the cleared store, to prove the clear persisted too.
|
||||
fresh = Controller({"setpoint_entity": "number.sp", "meter_source": "off"},
|
||||
_Hass(), store, _P(), stop=asyncio.Event())
|
||||
check("...so the next restart comes back armed and untripped, as it should",
|
||||
not fresh.sign_wd.tripped)
|
||||
|
||||
# ⚠️ THE WRITE ORDERING IS AN INVARIANT, SO IT GETS AN ASSERTION. main.py writes
|
||||
# `sign_reason` and THEN `sign_tripped`, each one its own `save()`, so that a
|
||||
# process that dies between the two leaves a reason nothing reads - harmless -
|
||||
# rather than a latch with no explanation for the operator who has to decide
|
||||
# whether to clear it. Documented reasoning is not enforcement: swapping those two
|
||||
# lines used to pass every check in this file.
|
||||
#
|
||||
# The death is modelled as the second write raising. In the field it is a power
|
||||
# cut or a container kill (Store.save() swallows OSError rather than raising), so
|
||||
# what is asserted here is the PROPERTY - what survives on disk - not the
|
||||
# mechanism.
|
||||
|
||||
|
||||
class _CrashOnFlag(_MemStore):
|
||||
def set(self, k, v):
|
||||
if k == "sign_tripped" and v:
|
||||
raise RuntimeError("power cut, mid-trip")
|
||||
super().set(k, v)
|
||||
|
||||
|
||||
async def _crash_mid_write():
|
||||
store = _CrashOnFlag()
|
||||
hass = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
c = Controller(opts, hass, store, _P(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
died = False
|
||||
for _ in range(12):
|
||||
try:
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
except RuntimeError:
|
||||
died = True
|
||||
break
|
||||
await asyncio.sleep(0.25)
|
||||
return store, died
|
||||
|
||||
|
||||
crashed_store, died = asyncio.run(_crash_mid_write())
|
||||
check("the second write is the one that sets the flag", died)
|
||||
check("a crash between the two writes leaves the REASON on disk",
|
||||
"SIGN_DISAGREEMENT" in crashed_store.data.get("sign_reason", ""))
|
||||
check("...and never a latch with nothing to explain it",
|
||||
not crashed_store.data.get("sign_tripped"))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
Reference in New Issue
Block a user