The probe's trade was sized at the probing battery's rating. Its SAFETY-73
pin held 200 W of that, and the allocator put the rest on a battery with no
mode range (one in a maintenance phase): TEST-23 OPT-15 g7, -2300 W on A in
its maintenance charge for 34 s, grid 3100 W.
modetrade.decide() now asks PROBE_W for the probing battery plus what the
other chargers would have had without the probe; size() adds the probe on top
of their share, or files PROBE_W exactly, or nothing. _mode_trade() carries
the pin only on the ticks it is filed, so the window's first and last cycle
do not move another battery's share either. Modes off and modes on with no
probe are unchanged (bf9019e digests). Tests: test_opt20.py.
Co-Authored-By: Claude <noreply@anthropic.com>
- test_price_secret.py: the fixed-tariff note on the real /config/validate
route, EN and NL, and none for a spaces-only profile (web.py lang wiring).
- test_price_service.py: the start line is INFO, not WARNING; a dismiss that
raises does not stop the cycle.
- test_maint13/test_setup_only/test_watchdog: ignore only the dismiss of the
old card, so a create with that id is still counted.
- DECISIONS rule 7 quotes the settings note as it is; messages.py comment.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
G1: remove the false 'Fixed tariff not used' notification. One INFO line at
start and an info note beside the setting (EN/NL) when price_service has a
non-blank static_profile; the old notification id is dismissed at start.
DOCS, migration step 5 and DECISIONS rule 7 now say what the code does.
S05: whitespace-only static_profile counts as not set.
G2: maintenance_enabled read through MaintConfig.from_options().
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The spaced-token check used a 5-character token, which the new 16-character
rule refuses on its own, so a validator that stopped checking spaces passed
(reviewer mutation R06). It now uses a long token and checks the reason.
Also pin F3 with no maintenance_enabled key: the default (off) holds and no
no-price words show (reviewer mutation S04). Tests only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
F1: every password option is shown as ******** (set) or empty in /config/model
(options, running, ui) and in a stale refusal; the classic page draws it as a
password field; a save or validate that sends ******** or nothing keeps the
stored value. F2: a static_profile beside price_service is said once at start
(notification and log), not refused. F3 (owner, 2026-10-14): the no-price row,
Home line and notification only while maintenance_enabled is on. F4: tests for
the reviewer's R01 and R10. F5: price_service_token must be 16+ characters.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- DOCS: the migration note said markup and taxes do not matter; with the
provider they are added to the wholesale price. Step 4 and 5 now say what
they set and what static_profile does while no source has a price.
- The gap tests run the notification through cycle(), where the check is
called, so a check that is never called goes red.
- test header: the real-transport checks are section 11.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- The notification, status row and Home line name an earlier day in the
language of the text ("13 okt om 21:00"); the Dutch title is "Prijzen
ontbreken", so the body no longer repeats it.
- The token request does not follow redirects: the host is fixed in code.
- A step back up to the saved prices is one INFO line.
- Tests: whole status payload free of the token, a redirect, the 5-decimal
edge of the old average, modes plan equal to generic_dayahead's.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
A new price source, `price_provider: price_service`: the owner's price server,
one fixed HTTPS host, a bearer token (new password option
`price_service_token`), wholesale energy only so markup and taxes are added as
for generic_dayahead.
The chain is server, then energy-charts, then the prices the history store
kept. A step counts only if it has a price for now. Each step down and back up
is one log line. With every source down a site plans from what it saved.
No price for now: one status row, one Home plan line and one notification, in
English and Dutch, cleared when a price returns. With this provider the
maintenance charge gate reads the provider's prices and keeps the Home
Assistant rule: the current 15-minute price is at or below today's average.
The token is hidden on the settings page, refused when missing, and taken out
of any error text. Other providers, `off` and the Home Assistant pair take the
road they always took (scripted-day probe against 0ce7d35: one line differs,
the refusal that lists the known providers). See
DECISIONS/PRICE-01-own-price-server.md.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Reviewer mutations survived the round-2 page checks: Start forced always
disabled (|| true), and the two flags swapped between Start and Stop,
because the checks only looked for each flag somewhere in the file. The
check now pins each flag to its own button. No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Stop cycle is disabled on a battery that is not cycling. Start cycle is
disabled while any battery cycles and on a switched-off battery. Page only;
the add-on still refuses each of these. DECISIONS notes the one-battery case.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Two reviewer mutations survived the suite: the web layer routing only a
truthy unit (an empty unit then started the bare pick), and the page
showing the server's English instead of its own sentence by code. Both
are now checked. The bare maint_start comment that said a per-battery
unit would ship half a surface is replaced by a pointer to
_maint_unit_action(). No behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
maint_start and maint_abort take an optional unit. With two or more batteries
each Batteries card has Start cycle and Stop cycle buttons. One slot per site
stays: a start while a battery cycles is refused and names it (no queue). A
battery that is switched off, an unknown unit, and a stop on a battery that is
not cycling are refused with a plain message. A request with no unit is the
old call. The scheduler and the phase machine are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Two survivors of the review's mutations get a check each in
test_price_run_fixes.py (X1: a held export credited negative in the rolled
quarter; X4: the hold extended by a reading already past E). DECISIONS: the
slow-battery quarter (3456 W, same on e3e4ba6) and the replay of a
maintenance phase starting during the hold.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
Conflicts (5 files, 9 hunks) resolved keeping both sides:
- p1.py: held_t (OPT-15) beside held_since (SAFETY-90).
- modetrade.py: chargers() takes targets (P4) and probe (OPT-15); decide()
clears the chargers, a probing refuser included, while a battery drains
(SAFETY-78); the docstring lists both rules.
- main.py: the roll goes into the SAFETY-90/91 projection chain
(`_peak_proj`); the SAFETY-95 drain-tail grid_w keeps the run-edge hold on
its other branch; the P4 forecast state and the hold state both stay.
- DOCS.md, DECISIONS: both lines kept, OPT-15 item refreshed.
Adaptations the merge needs:
- SAFETY-81 x F1: a rolled projection is not graded by the saturation alarm
until the quarter's first sample, as the old edge tick was not, so a
standing overload is still notified once per quarter.
- test_safety81, test_modes_p4: modes-on pins re-pinned (with a note), modes
off pinned to e3e4ba6; test_price_run_fixes: identity pins on e3e4ba6,
F1 reproduced at one inverter (SAFETY-91 already holds two), tests for the
drain and the day plan against the probe.
Co-Authored-By: Claude <noreply@anthropic.com>
- a 502 or refused read turns waiting on, the next good read off, and a
read timeout never (two mutants survived without this)
- the flag changes no write with live readings, not only with 502 ones
- the page script's amber dot and batteries-tab banner for "waiting"
- DECISIONS: about 5 minutes per start stage, not "at most"
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Supervisor proxy answers 502 to every add-on read, write and websocket
until Core is RUNNING (proxy.py api()/websocket() -> check_api_state()), so
the add-on cannot control while a slow integration holds HA's start, even
with its entities live. Measured on a safety112 repro stack with the
2026.08.0 proxy code: first write 1.0-4.4 s after RUNNING, 238-300 s after
live readings. Not routed around (DECISIONS/SAFETY-112-...).
While the API does not answer, the first status row is red and is the
banner ("Waiting for Home Assistant to finish starting"), Home shows a
"waiting" state in EN/NL instead of "Needs you now", and the log adds a
"still waiting" line every 5 minutes and the wait's length at the end.
A safety stop, a stalled loop or shadow mode keeps its own headline.
Control, writes, heartbeat and the stand-down are unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The new status row's id `solar_forecast` had no Home title, so Home showed
it under the fallback "Inverter connection". Add "Solar forecast" /
"Zonneprognose" to ui_text, and checks for the title, the tomorrow-gap hint
and blank list rows (review mutations R7, R9, R14 now killed).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.
- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
day is summed. Hourly splits are merged when every member has one, else
the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
day's forecast unusable (no partial sum). A caution row names it by
position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.
DECISIONS/OPT-17-several-forecast-entities.md has the rules.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
SAFETY-107 row names the tested base; MAINT-17 says code reading only;
SAFETY-105 figure is from a simulation; SAFETY-97 edge is 175 W; the
maintenance note cites MAINT-14 and MAINT-15; SAFETY-108 "about 15 s".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
HOLD's time check moves into Maintenance._hold(), used by step() and
_no_soc(). A hold that loses its SoC now ends at hold_min, writes
last_completed and logs the same COMPLETE line. The 15 min HOLD line says
the hold still ends at its normal time. Behaviour with a reading is
unchanged (differential trace against db9e231).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- A price-provider site with no fixed tariff is not a gate (its plan never
sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
test_static_tariff forbids main.py reading `static_profile`; a small
static_gated() in static_tariff.py answers it, and the Controller keeps the
answer in `_price_gated` beside `cheap`.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- gate_open is true with no price gate set up, in a cheap window, or while the
pack is taking charge; the stall rule and timeout now work on a no-tariff site.
- reset the save timer on a phase change; exact 5 min gap-cap test.
- test_safety93: original timeout scenario kept (B finished) plus a case where a
due B takes the slot after A's failure.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.
No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The test table gives 1.5 kW at N=2 and 3.9 kW summed at N=3 under a
surplus, and about 1 kW after a lost link without one; not 1.9 kW.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Mutation M13 (a battery out of the split counted in the house point)
survived; a direct check now kills it. win[0] is read through a guard
(test_named_absence).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While a battery settles from its ended drain (SAFETY-95), the house point
was grid + every battery's reading. A register can be 10 s older than the
meter, so B swung 860 -> 1650 -> 870 W on A's old reading (rig check 5).
Now the house point is held and moved only as far as the meter proves:
each battery is between its last changed reading and its commands since
(a reading that changed this cycle, or a refused side, as it reads).
N=1 and 1 s registers are byte-identical to release/1.0.
DECISIONS/SAFETY-103-old-readings-after-a-drain.md, test_safety103.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-103 swing 'by about 800 W for about 5 s'; SAFETY-99 'late, by less
than 30 s'; MAINT-10 row: one-at-a-time is not new; SAFETY-96: drop the
test-only 800 W; SAFETY-90 and MAINT-10 rows trimmed to two sentences.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>