EV-18: no floor alarm at a quarter's start while the car explains the excess
EV-15 rig F-A: with both batteries at the peak reserve and the car charging,
PEAK_GUARD_FLOOR_LIMITED and goodwe_peak_soc_floor fired at a quarter's start
and stayed red for the quarter, the excess smaller than the car. Two causes,
both held by the per-quarter latch `_car_need_excl`:
- C2: "without the car" assumed the batteries give 0 W from now on, so what
  the loop still gives below the reserve counted as house (T2 red on base);
- C1: one cycle with no trusted car figure latched it for the quarter (T1).

Owner 2026-11-19 (Q1-Q3): without the car the batteries keep giving what they
give now (lower of two readings, every cycle); a house need seen with a
trusted car figure stays latched to the quarter's end (`_car_need_house`); an
unknown car figure keeps the alarm only while it is unknown. A car known to
draw nothing (fresh reading, not charging) still grades the house's own need.
After a restart or a gap only the rest of the quarter is graded without the
car. A 0 W figure explains nothing outside our own pause (EV-15). The guard's
claim, floor, setpoints and charger writes are unchanged (N4: 41 runs, same
command digests as base).

test_ev18.py: the test plan's T1-T18, T2b, T2c, N2-N5 (tools/ev18_peak.py:
the real Controller across one quarter edge, N=2 at the reserve).

Co-Authored-By: Claude <noreply@anthropic.com>