Release 0.22.0 #250

Merged
admin merged 3 commits from release-0.22.0 into release/1.0 2026-11-14 13:21:22 +01:00
Owner

Release cut 0.22.0 on release/1.0 (owner go 2026-11-14). Changes only goodwe_controller/config.yaml (version 0.21.0 -> 0.22.0) and goodwe_controller/CHANGELOG.md. Minor bump, no option change. Not merged here; no tag, no deploy. The master PR is opened by the reviewer.

MAINT-28 does not ship: #247 and its revert #249 cancel out (tree of 4c0122a = tree of 1b5f7c9).

The CHANGELOG section:


0.22.0

A minor bump: a battery's monthly charge now gets the cheap night, the plan knows about the 7-day wait, a slow meter is followed more gently, and one peak-guard stop no longer costs a night charge its whole period. No option changes.
No option was added, removed or renamed, and no default changed (86 options). Existing installs need no option change: options that start 0.21.0 also start 0.22.0, and the Supervisor form is the same. It is a minor bump because control acts differently in the cases below; every saved setting still starts.

A battery's monthly charge gets the cheap night. While one battery is in the charge part of its monthly cycle, the other battery no longer grid-charges ahead of it, and the charge aims at this month's highest peak, as the peak guard does, not at the lower limit. In a rig test with the live setup (two batteries, one in its monthly charge), the cycling battery charged at about 1.5 kW in every cheap quarter (13.3 kWh in a night) and the other battery bought nothing; before, it charged at about 225 W or not at all. The peak limit was kept. At the start of a month, before a peak above the limit has been seen, this charge is much slower (SAFETY-111).

The plan knows about the 7-day wait. After a failed monthly cycle, Home no longer shows a cycle every night. It says the cycle waits, and shows the day the wait ends. The cycle tries again at the first start hour after the wait (MAINT-26). In a rig test no cycle was drawn during the wait, and none started.

One peak-guard stop no longer costs the night charge its period. With battery modes on, a night grid charge that the peak guard stops early in a 15-minute period used to stay stopped until the period ended. It may now start again after a minute, once per period, and not in the last minute. A real overload is cut as fast as before. In a rig test of the 01:00 case the night's charge was 0.45 to 0.46 kWh, against 0.42 to 0.44 kWh before. The status says "grid charge paused, it tries again in a minute" while it waits.

A slow meter is followed more gently. With a meter whose readings come about 4 s or more apart, such as a 5 s meter, control now takes smaller steps after a big change until the meter shows it. With Home Assistant readings 10 s late, less power goes to the grid when loads switch on and off: 44 % less in a simulation and 29 % less in a rig test. Meters of 1 or 2 s are left alone by design (the same commands in 63 simulation runs). With readings 15 s late the gain is smaller (19 % in a simulation), and a rig test sent more to the grid than before; see the known issues.

No change in behaviour: the comments in the main program file are shorter, and the file is split into smaller files by job. A rig test saw the same start-up, stops and commands.

Contents of this release, in merge order since 0.21.0 (5e00cbb):

56fc41f The comments in the main program file are shorter and clearer. There is no change in behaviour (MAINT-20, #224)
8508ac3 The main program file is split into smaller files by job. There is no change in behaviour; a rig test saw the same start-up, stops and commands (MAINT-21, #243)
a8ecf17 With a 5 s meter, control follows the meter more gently after a change. With Home Assistant readings 10 s late, less power goes to the grid when loads switch on and off. Meters of 1 or 2 s are left alone (SAFETY-136, #244)
02eac3b A night grid charge that the peak guard stops early in a 15-minute period may start again after a minute, once per period, instead of staying stopped until the period ends. A real overload is cut as fast as before. Battery modes only (SAFETY-135, #245)
1b5f7c9 While a battery's monthly cycle charges, the other battery no longer grid-charges ahead of it, and the charge aims at this month's highest peak, so it gets the cheap night. After a failed cycle, the plan no longer shows a cycle every night and says the cycle waits (MAINT-24, MAINT-25, #246)
f3f9483, 4c0122a History only: MAINT-28 was merged (#247) and then taken out again (#249). The two cancel out and the code is the same as at 1b5f7c9. MAINT-28 is not in this release (MAINT-28)

Known issues

  • A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge (SAFETY-92).
  • A battery capped at a low limit with a perfectly flat reading can still trip the stale check (SAFETY-74).
  • A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses (SAFETY-97).
  • The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s. This is about the guard's discharge only; a grid charge is cut back since 0.19.2 (SAFETY-99).
  • Two inverters: the maintenance charge can switch on and off while the house is above the peak aim (SAFETY-88).
  • Two inverters: the "circulating" figure counts a battery's reading at rest (SAFETY-98).
  • Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s (SAFETY-104).
  • Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once (SAFETY-101).
  • Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation (SAFETY-105).
  • Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old (SAFETY-106).
  • Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on (SAFETY-108).
  • Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site (MAINT-17).
  • When the 15-minute demand forecast sensor counts the battery's own charge, the maintenance charge runs at about half the power the peak limit leaves, so it takes about twice as long (seen on a site: about 1.2 kW instead of 2.5 kW; the peak limit was kept). At the start of a month, before a peak above the limit, that is about 2 kWh a night in a rig test: the cycle can reach its 36 h limit after about 4 nights and fail, and since 0.22.0 the other battery gets no grid charge on those nights (SAFETY-111).
  • One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min (SAFETY-102).
  • After a Home Assistant restart, control still waits until Home Assistant has finished starting, which can take several minutes, though the readings are already there (SAFETY-115).
  • While Home Assistant is not answering, the page can list inverters as refusing commands and sensors as missing, and send you to Developer Tools, though they are fine (UX-37).
  • If Home Assistant hangs or stops, the page keeps saying "Waiting for Home Assistant" and never turns into an alarm (SAFETY-113).
  • Right after Home Assistant has started, the page can say for about 4 s that an inverter cannot be controlled, and the first command can come late (SAFETY-114).
  • After a Home Assistant restart, the controller status sensor can still say "running" while the add-on cannot control. It was seen once, and the cause is not known (SAFETY-116).
  • Battery modes on: after a planned top-up from the grid, the Batteries screen can say "Enough sun is forecast" (UX-32).
  • Battery modes on: the forecast line "we count on" can show more sun than the plan counts, because the plan takes house use off first (UX-33).
  • Battery modes on: before a planned top-up, the Today list shows a smaller "gives" amount than the plan will use; it grows as the charge happens (UX-34).
  • Two inverters, battery modes on: while the other battery is in its maintenance charge, a battery's card can say it charges from the grid while it stays at 0 W (OPT-18).
  • Two inverters, battery modes on: while a battery refuses to charge in a cheap run, the action log on the page gets about 8 lines an hour for its retries, and the page hint says "waiting for a better price" (UX-38).
  • A battery in a safety stop, or one the add-on cannot reach, can still be started for a cycle, and its drain then waits about 12 h and ends in a failed-cycle notice. This comes from reading the code; it has not been seen on a site (MAINT-19).
  • On the Settings page, the rows of the solar forecast lists are labelled "Phase 1", "Phase 2" instead of "Sensor 1", "Sensor 2" (UX-27).
  • In the solar forecast list, a blank or repeated row makes "source 2 of 2" count differently from the rows on the Settings page (UX-28).
  • The solar forecast message says "has no reading" also when the sensor shows a number that is too old or in the wrong unit (UX-29).
  • If you use only the forecast lists, two Settings notes sit on the single-sensor field, and one of them tells you to set that field (UX-30).
  • After a restart during a price outage, the "No prices" message can say "yet" when prices did come in earlier (UX-39).
  • On the new settings page, you cannot see whether a price service token is set. Check the Configuration tab (UX-41).
  • On the classic settings page, the first click on Save after editing a field can do nothing. Click again (UX-42).
  • A steady overload on a 1 s meter can warn, and send the Home Assistant notification, 2 or 3 times at the start of each 15-minute period instead of once. The peak limit is still kept (SAFETY-122).
  • A fixed tariff is priced once per hour, so a price window that starts or ends at :15, :30 or :45 gets the wrong price for part of that hour. Windows that start and end on the hour are right (TARIFF-23).
  • Step 6 of the setup wizard stays empty because of an error in the page, in English and in Dutch (UX-51).
  • On Dutch pages, refusal texts, the last-event line under the Home buttons, the installer details and the trading status sentences are still English, and a few Dutch texts read badly, such as "1 metingen geweigerd" (UX-52).
  • Some price texts say "hour" where the add-on acts on a 15-minute period, such as "cheapest hour" (UX-47).
  • After the add-on restarts, the Home price chart shows no price for the earlier part of today, and the setup check can say "12 of 24 hours", though the prices are known (UX-48).
  • With battery modes on and only batteries on "Leftover solar", the Home price chart can mark a cheap period where no battery charges (UX-49).
  • On a phone, the bars of the Home price chart are too thin to tap one 15-minute period. The arrow keys work (UX-50).
  • In the last second of a 15-minute period, being a few watts over the aim can make the peak guard ask a battery for full power for one second. When a charge ends on a period edge, the last-second give can fade out over about 10 s, and a rig test exported up to 7.4 kW for about 8 s (SAFETY-124).
  • During the night grid charge, a 15-minute period can end 6 to 14 W over the peak aim, because the battery charges harder than asked. This was seen in simulation; a rig test saw 2 to 8 W (OPT-35).
  • The test rig could not bring back the false peak alarm that SAFETY-126 fixes, so that fix is shown in simulation only. Watch the notifications for a few nights (TEST-35).
  • The night cheap run is sized for the batteries' full charging power, not for what the peak limit leaves. Under a tight limit the run can end before the batteries reach their level, and Home can show a level they do not reach (79.9 % against a shown 95 % in a rig test) (OPT-25).
  • By day, a Leftover solar plan that has only a daily forecast figure counts the sun from now, not from when the figure was read. It counts about 22 % too much for a figure one hour old; the night plan is not affected (OPT-30).
  • The night charge can buy too much in a house that uses more at night than by day, such as one with a car charger or heat pump, and on a sunny day, because spare sun in one expensive hour does not count for the later ones (OPT-31).
  • A cheap run that has already started can overlap a new give run after a re-plan, so a battery can charge from the grid at the dearest price for part of an hour. This was seen in a test case, not on a site. Also in 0.19.2 (OPT-32).
  • If the solar forecast sensors stop updating before 17:00, as in winter or further north, there is no forecast from three hours after their last update until 20:00 (OPT-33).
  • With a forecast that gives only a daily total, the sun is spread an hour off on the two clock-change days after the change. The day's total is right (OPT-24).
  • The add-on learns the house's use only once a solar forecast is set, so a site that adds a forecast later waits one more day for its first plan (OPT-26).
  • Home says "No trading on price yet: no prices have arrived" when every battery is on Solar first, though the prices are shown (UX-55).
  • The Home plan header can say "Charges in the cheapest hour, gives power in the dearest" when Home draws no charge, and it says "hour" for 15-minute prices (UX-56).
  • While the peak guard holds back charging, Home hides the rest of the cheap run and gives no reason. The charge starts again when the guard lets go (UX-57).
  • With battery modes on and selling on, Home can draw a "Sells up to" block when the add-on judges the trade not worth it, and then it will not sell (UX-58).
  • Home, the plan and the Forecast tab stop drawing a battery's give at the trading floor, though control goes on giving down to the battery's cut-out (UX-59).
  • During a price outage, the Batteries screen says "Prices differ too little" and Home says "The price gap is too small" (UX-60).
  • With battery modes on and no meter, or a meter that is a Home Assistant entity, a grid charge is not possible and nothing says so (UX-61).
  • On the Batteries screen, a charge the add-on refused in a cheap run reads as "Saves its power for ...", for up to 15 minutes (UX-62).
  • A Leftover solar battery with no capacity set never charges from the grid when a solar forecast is set, and nothing warns about it (UX-63).
  • The "How the modes work" box on the Batteries screen does not describe Cheap hours only (UX-64).
  • With battery modes on, Settings still shows "Trade on the price spread", which the modes ignore. A site with modes on and no price source starts, and the Batteries screen says "No prices, so it follows the house" without pointing to Settings (UX-65).
  • With battery modes off and several equal prices in a row, Home and the Forecast tab draw one price quarter, while the add-on trades every quarter of the run (UX-67).
  • Late in the day, the Forecast tab's "now" line and last bars sit over the axis labels at the right edge (UX-68).
  • The Forecast tab's level curve charges at each battery's full rating. Under a peak limit the levels it draws are too high and a charge block can end early (54.6 % shown against 39.7 % in a rig test) (UX-70).
  • The peak forecast check says maintenance charging is not kept under the peak limit when no peak forecast is set, but since 0.19.2 it is (UX-73).
  • The peak guard row can show the same figure twice, such as "at this rate 3 500 W, over 3 500 W". Also in 0.19.2 (UX-74).
  • If the inverter's setpoint entity appears in Home Assistant after the add-on has started, the page keeps saying "Inverter control: not found in Home Assistant" and the batteries say "An alarm stopped control" until a restart, though control runs (UX-75).
  • In the last minute of a 15-minute period, with Home Assistant readings 30 s late, the period can end about 80 W over the peak aim and over the limit: 3 530 W against a 3 450 W aim and a 3 500 W limit in a rig test with a 2 kW load added 45 s before the end. The peak guard sees the load too late to hold it back (SAFETY-133).
  • With Home Assistant readings 10 s late, the grid charge in a cheap run can swing by several kW. In a test the add-on asked for an 8.7 kW charge (9.6 kW on 0.20.0) (SAFETY-132).
  • A plan rebuilt while the battery levels are missing for a moment can drop a cheap run that has not started yet, so the battery does not charge that day. Seen in a replay of real prices, where it cost about EUR 0.40 of extra grid use; the Leftover solar change in 0.20.1 no longer triggers it in those replays, but the cause stays (OPT-37).
  • On a 5 s meter, Home Assistant readings 10 s late are still not caught, and readings 15 s late only after about 4 minutes. Control now follows the meter more gently, so less goes to the grid: in a simulation with a changing load, 340 Wh became 189 Wh at 10 s late and 363 Wh became 296 Wh at 15 s late. In a rig test, 15 s late exported 13 to 19 % more than before (SAFETY-136, SAFETY-134).
  • With readings 10 to 15 s late, the hold can end in the middle of the delay and the swing can come back. Seen in rig tests with a 2 s and a 5 s meter (SAFETY-134).
  • With readings 10 s late on a 1 s meter, the grid can still move between -422 and +340 W while the batteries are held. With a very long delay (30 to 90 s) the request can swing by about 900 W every few seconds. Seen in review tests (SAFETY-130).
  • A battery that answers very slowly (10 s or more) can be taken for late Home Assistant readings and held, and the page then blames Home Assistant. A GoodWe battery settles in about 6 s and this has not been seen on one (SAFETY-131).
  • The page row for late readings reads awkwardly in English ("Home Assistant readings show requests about N seconds late, so control holds the batteries"), and the Dutch text misses a word (UX-78).
  • When the add-on stops, a write that takes more than 2 s can still land after the 0 W, and the 30 s safety timer on the ESPHome board then sets 0 W. After the Stop button, a cycle that had already decided can send its share (560 to 670 W) just after the 0 W; the next cycle sends 0 W again (SAFETY-138).
  • In the last hour of a cheap run, Home can draw a battery's grid charge up to an hour past the time control stops charging it. It only draws too much, never too little (UX-79).
  • A tomorrow solar forecast sensor that reports just after midnight with yesterday's value can be used as the new day's forecast for up to 12 hours. This has not been seen on a site (OPT-39).
  • During a cheap-hours charge, at some 15-minute boundaries the add-on sends 0 W for one tick ("no trade (headroom)") and then goes on. Seen in a rig test, in 5 of 8 cases; once, with a frozen battery reading, it left a battery at 0 W until 23:45 (OPT-40).
  • During a real peak, a battery in its maintenance charge can switch between charging and giving, about 400 times in 45 minutes in rig tests. That means more wear, but no higher peak (MAINT-28).
  • While one battery's monthly cycle charges, the other battery's card on Home says "Saves its power for higher prices", and the plan still shows its grid charge in the cheap hours, though it will not charge (UX-80).
  • After a failed monthly cycle, the plan line shows the day the wait ends, such as 18 November, not when the cycle tries again, such as 19 November at 19:00 (MAINT-26).
  • At the start of a cheap window the peak guard can step once although the period is under the aim, and the step can land on a battery in its monthly charge. In a rig test it gave 1.7 to 2.3 kW for 6 s (SAFETY-140).
  • A grid charge at full power in the last seconds of a 15-minute period can run into the next period, where the peak guard cuts it back (SAFETY-139).

🤖 Generated with Claude Code

https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC

Release cut 0.22.0 on `release/1.0` (owner go 2026-11-14). Changes only `goodwe_controller/config.yaml` (`version` 0.21.0 -> 0.22.0) and `goodwe_controller/CHANGELOG.md`. Minor bump, no option change. Not merged here; no tag, no deploy. The master PR is opened by the reviewer. MAINT-28 does not ship: #247 and its revert #249 cancel out (tree of `4c0122a` = tree of `1b5f7c9`). The CHANGELOG section: --- ## 0.22.0 **A minor bump: a battery's monthly charge now gets the cheap night, the plan knows about the 7-day wait, a slow meter is followed more gently, and one peak-guard stop no longer costs a night charge its whole period. No option changes.** No option was added, removed or renamed, and no default changed (86 options). **Existing installs need no option change:** options that start 0.21.0 also start 0.22.0, and the Supervisor form is the same. It is a minor bump because control acts differently in the cases below; every saved setting still starts. **A battery's monthly charge gets the cheap night.** While one battery is in the charge part of its monthly cycle, the other battery no longer grid-charges ahead of it, and the charge aims at this month's highest peak, as the peak guard does, not at the lower limit. In a rig test with the live setup (two batteries, one in its monthly charge), the cycling battery charged at about 1.5 kW in every cheap quarter (13.3 kWh in a night) and the other battery bought nothing; before, it charged at about 225 W or not at all. The peak limit was kept. At the start of a month, before a peak above the limit has been seen, this charge is much slower ([[SAFETY-111]]). **The plan knows about the 7-day wait.** After a failed monthly cycle, Home no longer shows a cycle every night. It says the cycle waits, and shows the day the wait ends. The cycle tries again at the first start hour after the wait ([[MAINT-26]]). In a rig test no cycle was drawn during the wait, and none started. **One peak-guard stop no longer costs the night charge its period.** With battery modes on, a night grid charge that the peak guard stops early in a 15-minute period used to stay stopped until the period ended. It may now start again after a minute, once per period, and not in the last minute. A real overload is cut as fast as before. In a rig test of the 01:00 case the night's charge was 0.45 to 0.46 kWh, against 0.42 to 0.44 kWh before. The status says "grid charge paused, it tries again in a minute" while it waits. **A slow meter is followed more gently.** With a meter whose readings come about 4 s or more apart, such as a 5 s meter, control now takes smaller steps after a big change until the meter shows it. With Home Assistant readings 10 s late, less power goes to the grid when loads switch on and off: 44 % less in a simulation and 29 % less in a rig test. Meters of 1 or 2 s are left alone by design (the same commands in 63 simulation runs). With readings 15 s late the gain is smaller (19 % in a simulation), and a rig test sent more to the grid than before; see the known issues. **No change in behaviour:** the comments in the main program file are shorter, and the file is split into smaller files by job. A rig test saw the same start-up, stops and commands. Contents of this release, in merge order since 0.21.0 (`5e00cbb`): | | | |---|---| | `56fc41f` | The comments in the main program file are shorter and clearer. There is no change in behaviour ([[MAINT-20]], #224) | | `8508ac3` | The main program file is split into smaller files by job. There is no change in behaviour; a rig test saw the same start-up, stops and commands ([[MAINT-21]], #243) | | `a8ecf17` | With a 5 s meter, control follows the meter more gently after a change. With Home Assistant readings 10 s late, less power goes to the grid when loads switch on and off. Meters of 1 or 2 s are left alone ([[SAFETY-136]], #244) | | `02eac3b` | A night grid charge that the peak guard stops early in a 15-minute period may start again after a minute, once per period, instead of staying stopped until the period ends. A real overload is cut as fast as before. Battery modes only ([[SAFETY-135]], #245) | | `1b5f7c9` | While a battery's monthly cycle charges, the other battery no longer grid-charges ahead of it, and the charge aims at this month's highest peak, so it gets the cheap night. After a failed cycle, the plan no longer shows a cycle every night and says the cycle waits ([[MAINT-24]], [[MAINT-25]], #246) | | `f3f9483`, `4c0122a` | History only: MAINT-28 was merged (#247) and then taken out again (#249). The two cancel out and the code is the same as at `1b5f7c9`. MAINT-28 is not in this release ([[MAINT-28]]) | ### Known issues - A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]). - A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]). - A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]). - The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s. This is about the guard's discharge only; a grid charge is cut back since 0.19.2 ([[SAFETY-99]]). - Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]). - Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]). - Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]). - Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]). - Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]). - Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]). - Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]). - Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]). - When the 15-minute demand forecast sensor counts the battery's own charge, the maintenance charge runs at about half the power the peak limit leaves, so it takes about twice as long (seen on a site: about 1.2 kW instead of 2.5 kW; the peak limit was kept). At the start of a month, before a peak above the limit, that is about 2 kWh a night in a rig test: the cycle can reach its 36 h limit after about 4 nights and fail, and since 0.22.0 the other battery gets no grid charge on those nights ([[SAFETY-111]]). - One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]). - After a Home Assistant restart, control still waits until Home Assistant has finished starting, which can take several minutes, though the readings are already there ([[SAFETY-115]]). - While Home Assistant is not answering, the page can list inverters as refusing commands and sensors as missing, and send you to Developer Tools, though they are fine ([[UX-37]]). - If Home Assistant hangs or stops, the page keeps saying "Waiting for Home Assistant" and never turns into an alarm ([[SAFETY-113]]). - Right after Home Assistant has started, the page can say for about 4 s that an inverter cannot be controlled, and the first command can come late ([[SAFETY-114]]). - After a Home Assistant restart, the controller status sensor can still say "running" while the add-on cannot control. It was seen once, and the cause is not known ([[SAFETY-116]]). - Battery modes on: after a planned top-up from the grid, the Batteries screen can say "Enough sun is forecast" ([[UX-32]]). - Battery modes on: the forecast line "we count on" can show more sun than the plan counts, because the plan takes house use off first ([[UX-33]]). - Battery modes on: before a planned top-up, the Today list shows a smaller "gives" amount than the plan will use; it grows as the charge happens ([[UX-34]]). - Two inverters, battery modes on: while the other battery is in its maintenance charge, a battery's card can say it charges from the grid while it stays at 0 W ([[OPT-18]]). - Two inverters, battery modes on: while a battery refuses to charge in a cheap run, the action log on the page gets about 8 lines an hour for its retries, and the page hint says "waiting for a better price" ([[UX-38]]). - A battery in a safety stop, or one the add-on cannot reach, can still be started for a cycle, and its drain then waits about 12 h and ends in a failed-cycle notice. This comes from reading the code; it has not been seen on a site ([[MAINT-19]]). - On the Settings page, the rows of the solar forecast lists are labelled "Phase 1", "Phase 2" instead of "Sensor 1", "Sensor 2" ([[UX-27]]). - In the solar forecast list, a blank or repeated row makes "source 2 of 2" count differently from the rows on the Settings page ([[UX-28]]). - The solar forecast message says "has no reading" also when the sensor shows a number that is too old or in the wrong unit ([[UX-29]]). - If you use only the forecast lists, two Settings notes sit on the single-sensor field, and one of them tells you to set that field ([[UX-30]]). - After a restart during a price outage, the "No prices" message can say "yet" when prices did come in earlier ([[UX-39]]). - On the new settings page, you cannot see whether a price service token is set. Check the Configuration tab ([[UX-41]]). - On the classic settings page, the first click on Save after editing a field can do nothing. Click again ([[UX-42]]). - A steady overload on a 1 s meter can warn, and send the Home Assistant notification, 2 or 3 times at the start of each 15-minute period instead of once. The peak limit is still kept ([[SAFETY-122]]). - A fixed tariff is priced once per hour, so a price window that starts or ends at :15, :30 or :45 gets the wrong price for part of that hour. Windows that start and end on the hour are right ([[TARIFF-23]]). - Step 6 of the setup wizard stays empty because of an error in the page, in English and in Dutch ([[UX-51]]). - On Dutch pages, refusal texts, the last-event line under the Home buttons, the installer details and the trading status sentences are still English, and a few Dutch texts read badly, such as "1 metingen geweigerd" ([[UX-52]]). - Some price texts say "hour" where the add-on acts on a 15-minute period, such as "cheapest hour" ([[UX-47]]). - After the add-on restarts, the Home price chart shows no price for the earlier part of today, and the setup check can say "12 of 24 hours", though the prices are known ([[UX-48]]). - With battery modes on and only batteries on "Leftover solar", the Home price chart can mark a cheap period where no battery charges ([[UX-49]]). - On a phone, the bars of the Home price chart are too thin to tap one 15-minute period. The arrow keys work ([[UX-50]]). - In the last second of a 15-minute period, being a few watts over the aim can make the peak guard ask a battery for full power for one second. When a charge ends on a period edge, the last-second give can fade out over about 10 s, and a rig test exported up to 7.4 kW for about 8 s ([[SAFETY-124]]). - During the night grid charge, a 15-minute period can end 6 to 14 W over the peak aim, because the battery charges harder than asked. This was seen in simulation; a rig test saw 2 to 8 W ([[OPT-35]]). - The test rig could not bring back the false peak alarm that [[SAFETY-126]] fixes, so that fix is shown in simulation only. Watch the notifications for a few nights ([[TEST-35]]). - The night cheap run is sized for the batteries' full charging power, not for what the peak limit leaves. Under a tight limit the run can end before the batteries reach their level, and Home can show a level they do not reach (79.9 % against a shown 95 % in a rig test) ([[OPT-25]]). - By day, a Leftover solar plan that has only a daily forecast figure counts the sun from now, not from when the figure was read. It counts about 22 % too much for a figure one hour old; the night plan is not affected ([[OPT-30]]). - The night charge can buy too much in a house that uses more at night than by day, such as one with a car charger or heat pump, and on a sunny day, because spare sun in one expensive hour does not count for the later ones ([[OPT-31]]). - A cheap run that has already started can overlap a new give run after a re-plan, so a battery can charge from the grid at the dearest price for part of an hour. This was seen in a test case, not on a site. Also in 0.19.2 ([[OPT-32]]). - If the solar forecast sensors stop updating before 17:00, as in winter or further north, there is no forecast from three hours after their last update until 20:00 ([[OPT-33]]). - With a forecast that gives only a daily total, the sun is spread an hour off on the two clock-change days after the change. The day's total is right ([[OPT-24]]). - The add-on learns the house's use only once a solar forecast is set, so a site that adds a forecast later waits one more day for its first plan ([[OPT-26]]). - Home says "No trading on price yet: no prices have arrived" when every battery is on Solar first, though the prices are shown ([[UX-55]]). - The Home plan header can say "Charges in the cheapest hour, gives power in the dearest" when Home draws no charge, and it says "hour" for 15-minute prices ([[UX-56]]). - While the peak guard holds back charging, Home hides the rest of the cheap run and gives no reason. The charge starts again when the guard lets go ([[UX-57]]). - With battery modes on and selling on, Home can draw a "Sells up to" block when the add-on judges the trade not worth it, and then it will not sell ([[UX-58]]). - Home, the plan and the Forecast tab stop drawing a battery's give at the trading floor, though control goes on giving down to the battery's cut-out ([[UX-59]]). - During a price outage, the Batteries screen says "Prices differ too little" and Home says "The price gap is too small" ([[UX-60]]). - With battery modes on and no meter, or a meter that is a Home Assistant entity, a grid charge is not possible and nothing says so ([[UX-61]]). - On the Batteries screen, a charge the add-on refused in a cheap run reads as "Saves its power for ...", for up to 15 minutes ([[UX-62]]). - A Leftover solar battery with no capacity set never charges from the grid when a solar forecast is set, and nothing warns about it ([[UX-63]]). - The "How the modes work" box on the Batteries screen does not describe Cheap hours only ([[UX-64]]). - With battery modes on, Settings still shows "Trade on the price spread", which the modes ignore. A site with modes on and no price source starts, and the Batteries screen says "No prices, so it follows the house" without pointing to Settings ([[UX-65]]). - With battery modes off and several equal prices in a row, Home and the Forecast tab draw one price quarter, while the add-on trades every quarter of the run ([[UX-67]]). - Late in the day, the Forecast tab's "now" line and last bars sit over the axis labels at the right edge ([[UX-68]]). - The Forecast tab's level curve charges at each battery's full rating. Under a peak limit the levels it draws are too high and a charge block can end early (54.6 % shown against 39.7 % in a rig test) ([[UX-70]]). - The peak forecast check says maintenance charging is not kept under the peak limit when no peak forecast is set, but since 0.19.2 it is ([[UX-73]]). - The peak guard row can show the same figure twice, such as "at this rate 3 500 W, over 3 500 W". Also in 0.19.2 ([[UX-74]]). - If the inverter's setpoint entity appears in Home Assistant after the add-on has started, the page keeps saying "Inverter control: not found in Home Assistant" and the batteries say "An alarm stopped control" until a restart, though control runs ([[UX-75]]). - In the last minute of a 15-minute period, with Home Assistant readings 30 s late, the period can end about 80 W over the peak aim and over the limit: 3 530 W against a 3 450 W aim and a 3 500 W limit in a rig test with a 2 kW load added 45 s before the end. The peak guard sees the load too late to hold it back ([[SAFETY-133]]). - With Home Assistant readings 10 s late, the grid charge in a cheap run can swing by several kW. In a test the add-on asked for an 8.7 kW charge (9.6 kW on 0.20.0) ([[SAFETY-132]]). - A plan rebuilt while the battery levels are missing for a moment can drop a cheap run that has not started yet, so the battery does not charge that day. Seen in a replay of real prices, where it cost about EUR 0.40 of extra grid use; the Leftover solar change in 0.20.1 no longer triggers it in those replays, but the cause stays ([[OPT-37]]). - On a 5 s meter, Home Assistant readings 10 s late are still not caught, and readings 15 s late only after about 4 minutes. Control now follows the meter more gently, so less goes to the grid: in a simulation with a changing load, 340 Wh became 189 Wh at 10 s late and 363 Wh became 296 Wh at 15 s late. In a rig test, 15 s late exported 13 to 19 % more than before ([[SAFETY-136]], [[SAFETY-134]]). - With readings 10 to 15 s late, the hold can end in the middle of the delay and the swing can come back. Seen in rig tests with a 2 s and a 5 s meter ([[SAFETY-134]]). - With readings 10 s late on a 1 s meter, the grid can still move between -422 and +340 W while the batteries are held. With a very long delay (30 to 90 s) the request can swing by about 900 W every few seconds. Seen in review tests ([[SAFETY-130]]). - A battery that answers very slowly (10 s or more) can be taken for late Home Assistant readings and held, and the page then blames Home Assistant. A GoodWe battery settles in about 6 s and this has not been seen on one ([[SAFETY-131]]). - The page row for late readings reads awkwardly in English ("Home Assistant readings show requests about N seconds late, so control holds the batteries"), and the Dutch text misses a word ([[UX-78]]). - When the add-on stops, a write that takes more than 2 s can still land after the 0 W, and the 30 s safety timer on the ESPHome board then sets 0 W. After the Stop button, a cycle that had already decided can send its share (560 to 670 W) just after the 0 W; the next cycle sends 0 W again ([[SAFETY-138]]). - In the last hour of a cheap run, Home can draw a battery's grid charge up to an hour past the time control stops charging it. It only draws too much, never too little ([[UX-79]]). - A tomorrow solar forecast sensor that reports just after midnight with yesterday's value can be used as the new day's forecast for up to 12 hours. This has not been seen on a site ([[OPT-39]]). - During a cheap-hours charge, at some 15-minute boundaries the add-on sends 0 W for one tick ("no trade (headroom)") and then goes on. Seen in a rig test, in 5 of 8 cases; once, with a frozen battery reading, it left a battery at 0 W until 23:45 ([[OPT-40]]). - During a real peak, a battery in its maintenance charge can switch between charging and giving, about 400 times in 45 minutes in rig tests. That means more wear, but no higher peak ([[MAINT-28]]). - While one battery's monthly cycle charges, the other battery's card on Home says "Saves its power for higher prices", and the plan still shows its grid charge in the cheap hours, though it will not charge ([[UX-80]]). - After a failed monthly cycle, the plan line shows the day the wait ends, such as 18 November, not when the cycle tries again, such as 19 November at 19:00 ([[MAINT-26]]). - At the start of a cheap window the peak guard can step once although the period is under the aim, and the step can land on a battery in its monthly charge. In a rig test it gave 1.7 to 2.3 kW for 6 s ([[SAFETY-140]]). - A grid charge at full power in the last seconds of a 15-minute period can run into the next period, where the peak guard cuts it back ([[SAFETY-139]]). 🤖 Generated with [Claude Code](https://claude.com/claude-code) https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
admin added 1 commit 2026-11-14 10:45:34 +01:00
Release 0.22.0: version and CHANGELOG
checks / unit (pull_request) Successful in 36m47s
infra-pin / fresh (pull_request) Successful in 1s
94214d609e
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
admin added 1 commit 2026-11-14 11:52:43 +01:00
Release 0.22.0: CHANGELOG fixes (duplicate Known issues heading, missing full stop)
checks / unit (pull_request) Successful in 27m4s
infra-pin / fresh (pull_request) Successful in 1s
634001cb26
Co-Authored-By: Claude <noreply@anthropic.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
admin added 1 commit 2026-11-14 12:54:21 +01:00
Release 0.22.0: CHANGELOG wording (SAFETY-136 row, SAFETY-111, MAINT-28, MAINT-26)
checks / unit (pull_request) Successful in 26m33s
infra-pin / fresh (pull_request) Successful in 2s
e79d403560
- SAFETY-136 row: the gain is at 10 s late; at 15 s a rig test sent more.
- SAFETY-111: the cycle needs more than 4 nights; the 36 h limit ends it.
- MAINT-28: rig counts were 393-468 flips per 45 min, not one figure.
- MAINT-26 / MAINT-25: the next try is the first start hour after the wait.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Author
Owner

REL-0.22.0 review (independent, Opus) of 634001c: fixes pushed as e79d403 (CHANGELOG wording only).

Checks on 634001c:

  1. Only config.yaml (version: "0.22.0") and CHANGELOG.md changed: PASS.
  2. Version 0.22.0 minor: PASS. git diff 5e00cbb..634001c is empty for app/validate.py, translations/, build.yaml, Dockerfile, requirements.txt, run.sh; config.yaml differs only in the version line. Option defaults: the 39 .get(key, default) reads in app/ and the PEAK/MAINT/SIGN *_OPTION_DEFAULTS dicts are identical to master. Installs need no option change.
  3. Contents table: PASS. git log --first-parent 5e00cbb..4c0122a does print the 7 merges (the same list as 16029d7..4c0122a; 16029d7 is in master, 4c0122a..5e00cbb is only the master merge and the trees of 16029d7 and 5e00cbb are equal). So the dev's bound is right but its reason ("prints nothing") is not: that was most likely the output filter on the dev's shell, not git. Tree 4c0122a = tree 1b5f7c9 (8846f0cb). 0.21.0 and older sections are byte-identical to master.
  4. Known issues: all referenced cards are To Do except SAFETY-97 (kept, owner asked), SAFETY-126 (only cited from TEST-35) and SAFETY-136 (Done, line describes what is left; SAFETY-134 is cited too). SAFETY-135 dropped: card Done. MAINT-28, UX-80, MAINT-26, SAFETY-140, SAFETY-139 match their cards.
  5. Plain text: one Known issues heading, no broken sentences after the fixes below.
  6. CI run 1652 (checks / unit (pull_request), job 2803, attempt 1) success on 634001c; test_version_gate and test_docs rc 0 locally (goodwe-addon-checks:1, --network none).

Findings (all goodwe_controller/CHANGELOG.md, fixed in e79d403):

  • F1 (medium, l.24, SAFETY-136 row): said "readings 10 to 15 s late ... less power goes to the grid". At 15 s late the rig test exported 13-19 % MORE than base (SAFETY-136 test check 2). Row now claims the gain at 10 s only.
  • F2 (medium, l.43, SAFETY-111): "need about 4 nights, longer than its 36 h limit" is self-contradictory (4 x 9 h = 36 h). MAINT-24 test check 4: at 2.03 kWh a night the cycle needs about 6.6 nights, the 36 h limit ends it after 4 nights, so it fails. Reworded, and cut to two sentences.
  • F3 (low, l.14): "Readings 15 s late gain less (19 % in a simulation)" hid that the rig was worse. Now says so and points to the known issues. Also "4 s or more apart" -> "about 4 s or more" (the rule is a median gap over 3.75 s, SAFETY-136 review F3).
  • F4 (low, l.110, MAINT-28): "468 times in one rig test": the MAINT-28 test recounted that run as 423 and saw 393-412 on 1b5f7c9 (the code that ships). Now "about 400 times in 45 minutes in rig tests. That means more wear, but no higher peak." (quarters stayed at the aim in both tests).
  • F5 (low, l.10 and l.112, MAINT-25/MAINT-26): "tries again at its start hour after that day" / "the next day" is only true when the wait ends after the start hour (the live case). Now "the first start hour after the wait"; the MAINT-26 line shows the day the wait ends, not the next try.

Checked and right as written: MAINT-24 figures (1.5 kW in 36 of 36 quarters, 13.3 kWh, 225 W base, peak kept), the "monthly charge gets the cheap night" wording does not promise one night; MAINT-25 shows the day the wait ends; SAFETY-135 figures (0.453-0.462 vs 0.415-0.441 kWh), "not in the last minute" (ctl_trade.py:407-414) and the status text (modetrade.py:86); SAFETY-136 does not claim 10 s late on a 5 s meter is caught; MAINT-20/21 say no change in behaviour.

**REL-0.22.0 review (independent, Opus) of 634001c: fixes pushed as e79d403 (CHANGELOG wording only).** Checks on 634001c: 1. Only `config.yaml` (`version: "0.22.0"`) and `CHANGELOG.md` changed: PASS. 2. Version 0.22.0 minor: PASS. `git diff 5e00cbb..634001c` is empty for app/validate.py, translations/, build.yaml, Dockerfile, requirements.txt, run.sh; config.yaml differs only in the version line. Option defaults: the 39 `.get(key, default)` reads in app/ and the PEAK/MAINT/SIGN `*_OPTION_DEFAULTS` dicts are identical to master. Installs need no option change. 3. Contents table: PASS. `git log --first-parent 5e00cbb..4c0122a` does print the 7 merges (the same list as `16029d7..4c0122a`; 16029d7 is in master, `4c0122a..5e00cbb` is only the master merge and the trees of 16029d7 and 5e00cbb are equal). So the dev's bound is right but its reason ("prints nothing") is not: that was most likely the output filter on the dev's shell, not git. Tree 4c0122a = tree 1b5f7c9 (8846f0cb). 0.21.0 and older sections are byte-identical to master. 4. Known issues: all referenced cards are To Do except SAFETY-97 (kept, owner asked), SAFETY-126 (only cited from TEST-35) and SAFETY-136 (Done, line describes what is left; SAFETY-134 is cited too). SAFETY-135 dropped: card Done. MAINT-28, UX-80, MAINT-26, SAFETY-140, SAFETY-139 match their cards. 5. Plain text: one Known issues heading, no broken sentences after the fixes below. 6. CI run 1652 (`checks / unit (pull_request)`, job 2803, attempt 1) success on 634001c; test_version_gate and test_docs rc 0 locally (goodwe-addon-checks:1, --network none). Findings (all `goodwe_controller/CHANGELOG.md`, fixed in e79d403): - **F1 (medium, l.24, SAFETY-136 row):** said "readings 10 to 15 s late ... less power goes to the grid". At 15 s late the rig test exported 13-19 % MORE than base (SAFETY-136 test check 2). Row now claims the gain at 10 s only. - **F2 (medium, l.43, SAFETY-111):** "need about 4 nights, longer than its 36 h limit" is self-contradictory (4 x 9 h = 36 h). MAINT-24 test check 4: at 2.03 kWh a night the cycle needs about 6.6 nights, the 36 h limit ends it after 4 nights, so it fails. Reworded, and cut to two sentences. - **F3 (low, l.14):** "Readings 15 s late gain less (19 % in a simulation)" hid that the rig was worse. Now says so and points to the known issues. Also "4 s or more apart" -> "about 4 s or more" (the rule is a median gap over 3.75 s, SAFETY-136 review F3). - **F4 (low, l.110, MAINT-28):** "468 times in one rig test": the MAINT-28 test recounted that run as 423 and saw 393-412 on 1b5f7c9 (the code that ships). Now "about 400 times in 45 minutes in rig tests. That means more wear, but no higher peak." (quarters stayed at the aim in both tests). - **F5 (low, l.10 and l.112, MAINT-25/MAINT-26):** "tries again at its start hour after that day" / "the next day" is only true when the wait ends after the start hour (the live case). Now "the first start hour after the wait"; the MAINT-26 line shows the day the wait ends, not the next try. Checked and right as written: MAINT-24 figures (1.5 kW in 36 of 36 quarters, 13.3 kWh, 225 W base, peak kept), the "monthly charge gets the cheap night" wording does not promise one night; MAINT-25 shows the day the wait ends; SAFETY-135 figures (0.453-0.462 vs 0.415-0.441 kWh), "not in the last minute" (ctl_trade.py:407-414) and the status text (modetrade.py:86); SAFETY-136 does not claim 10 s late on a 5 s meter is caught; MAINT-20/21 say no change in behaviour.
admin merged commit b700c0be92 into release/1.0 2026-11-14 13:21:22 +01:00
Author
Owner

Merged through the API at b700c0be922c17797a60305e027494003d76deaf ("Do":"merge", head_commit_id pinned to e79d403), after checks / unit (pull_request) run 1654 passed on e79d403 (job 2805, attempt 1, 12:54-13:20 CET, a real run). ls-remote: release/1.0 = b700c0b, master = 5e00cbb (unchanged). Master PR opened next; it is not merged (owner's call).

Merged through the API at `b700c0be922c17797a60305e027494003d76deaf` (`"Do":"merge"`, `head_commit_id` pinned to `e79d403`), after `checks / unit (pull_request)` run 1654 passed on e79d403 (job 2805, attempt 1, 12:54-13:20 CET, a real run). ls-remote: `release/1.0` = b700c0b, `master` = 5e00cbb (unchanged). Master PR opened next; it is not merged (owner's call).
Sign in to join this conversation.
No Reviewers
No labels
1 Participants
Notifications
Due Date
No due date set.
Dependencies

No dependencies set.

Reference: admin/goodwe-addon#250