Losing the solar forecast mid-run used to widen the gap at once and stop a
grid charge (and a sensor that went unavailable for a minute stopped and
restarted it). A run under way when the forecast is lost now keeps the gap it
was planned with until it ends (Controller.weather_held(), recorded by
_wx_track() each cycle a forecast is read); the wider gap applies from the next
run. The plan key holds the hold state so the plan rebuilds when it ends. Home's
mirror (homeview.trade_verdict) asks the same weather_held(now).
Tests: test_tariff24_weather.py part 4 (going: the charge continues to the run's
end, the next run is not_worth; flap of one and two reads: no stop, no restart;
Home agrees) and a test_modes_p4.py scenario that runs a forecast day at a gap
between 1x and 1.5x the cycle cost. DECISIONS wording follows.
Co-Authored-By: Claude <noreply@anthropic.com>
With a forecast read the gap needed is the cycle cost (0.20), not 1.5 x (0.30),
so a midday 0.21 gap now plans a grid top-up that four scenarios (sunny, Cheap
hours partly, forecast too high, refusal) are not about. They ask for cost 0.30
with the forecast; the no-forecast leg keeps 0.20 (= 0.30 widened).
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, the price gap a mode needs was always widened x1.5 by
Uncertainty.NO_WEATHER, even with a solar forecast read, so a 0.08 day/night
gap never traded at the shipped cycle cost. The doubt is now added only when
no usable forecast is read (solar_fc is None, the day plan's own test), in the
run plan (_price_runs), the charge gate (_mode_roles) and Home's mirror
(homeview.trade_verdict). The rule is one helper, arbitrage.weather_uncertainty();
the modes-off trade path (main.py cycle) keeps its literal NO_WEATHER.
DOCS "Battery modes" sentence, CHANGELOG 0.19.1 line and the DECISIONS note
follow. Tests: test_tariff24_weather.py.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, a day/night or fixed static_profile, no price feed and
arbitrage off, tariff_refresh_wanted() was false: no tariff task, no
tariff_plan, mode_runs None, so Leftover solar / Cheap hours never charged from
the grid and the Batteries screen said "No prices". packmode.enabled(opts) is
now a third term of the gate. With price_provider off the task is pure
arithmetic on static_profile, so no HTTPS call is added.
Also: version 0.19.1, CHANGELOG entry, DECISIONS note, test_tariff24.py, and a
shorter tariff_refresh_wanted() docstring (history stays in DECISIONS).
Co-Authored-By: Claude <noreply@anthropic.com>
Owner chose 0.19.0 (2026-10-26) because PRICE-02 changes trading behaviour.
Version and CHANGELOG heading/first line only; no option changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Bump version to 0.18.3 and add the 0.18.3 CHANGELOG section: DOC-8, UX-45,
SAFETY-119, SAFETY-121, UX-46, PRICE-02. A patch bump: no option added,
removed or renamed, no default changed.
Co-Authored-By: Claude <noreply@anthropic.com>
The production-shaped plan sees tomorrow from 13:00, so most buys are sold
the next day or later. The ledger forgot the open buy at each midnight and
booked 46 of 51 sales as holdings: 5 trips, +1.21 EUR. Carried over, the
same decisions give 51 trips, +13.81 EUR, all clearing the threshold.
Decisions are unchanged and identical on the old and new verdict. No
assertion changed.
DECISIONS: 27.5 -> 42.6 kWh is the refresh-:00, tomorrow-known variant; give
the range of the other three.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
- TariffPlan.arbitrage(now=...) is required (keyword-only, no default); so are
homeview.trade_verdict/refusal_key's now. Existing test calls pass one.
- test_arbitrage.py: no module-level decide wrapper. Fixtures that probed a
one-day plan after its extremes now hold two days (as a site does); the
flap day gets a unique cheapest and dearest hour; the replay breaks its
ties without direction. The flap bound is <= 4 and the replay check is
len(_trades) < 365 again. 228 checks pass on the old and the new code.
- test_price02.py part 6: ties (equal quarters, a real 15-minute day,
alternating hourly prices) and the required now.
- Identity pins: the masked digest is only for the older-tree comparison;
this tree's own digests are pinned with nothing hidden.
- DECISIONS: the tie analysis with numbers.
Co-Authored-By: Claude <noreply@anthropic.com>
test_price_run_fixes.py part 5 and test_modes_p3.py part 1 compare the modes-off
replay with digests printed on older trees. The trade sentence now says
"price period", and a sale quotes another "above the cheapest" figure once the
first cheap period is over. ident.trade_digest() hides exactly those two
things; re-measured on e3e4ba6, 7a00f12, 90bc901 and this tree, the digests
are the same, so every command is unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
TariffPlan.arbitrage(now=...) drops the points whose period has ended
(end <= now), so the cheapest and dearest point can still be traded.
decide() (modes off), the modes-on allowed() gate and the Home verdict
all pass their own now. Hourly feeds and the static tariff are unchanged.
The off-peak sentence and the charge/discharge sentences say "price
period". Tests: test_price02.py; test_arbitrage.py rolls its whole-day
plans to start at now; test_modes_p3.py part 1 digests leave the trade
sentence out (commands unchanged on 7a00f12, 90bc901 and this tree).
Co-Authored-By: Claude <noreply@anthropic.com>
Text only. "stroom te opnemen" -> "stroom op te nemen"; Developer Tools is
"Ontwikkelhulpmiddelen" in HA and ui_text; the green stuck-meter row no longer
starts "Vastgelopen meter:"; maintenance banner names the phase in Dutch;
double "dan" in the device note; plainer peak reserve, peak guard, refused
commands and missing-entity wording. Two stale comments now say the banner
and Home bodies follow the page's language.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Rows and banners are built once with their Dutch beside them (messages.Bi)
and status_payload() picks one by the page's language. Settings notes and the
wizard's checks carry a Dutch twin (Note.nl) that /config/validate picks by
the posted language. The peak forecast label drops "(W)" in EN and NL.
Co-Authored-By: Claude <noreply@anthropic.com>
The jittery-meter numbers depend on the draw (review: 4, 4, 5 of 11 at the
quarter edge; up to 4 quiet quarters at 20 s; first warning up to 61 min
later). Above about 40 s per cycle, a short bound can still use up the
budget when the wire changes hands every few cycles. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
TEST-23 F-1: on a 5 s meter a steady overload warned once in 70 min. The
loop was at its bound 4-5 cycles a quarter, all inside SAFETY-119's settle
of 12 cycles (60 s) and under its budget of 8 per 900 s. The simulation
fed the meter a cycle behind the battery reading, so the guard and the
charge chased each other and gave ~20 bound cycles a quarter.
The settle is now 4 cycles and 22 s (HANDBACK_CYCLES, SHORT_SPAN_S), and
the rolling budget one number, 11 per 900 s, at every cycle length. The
cycle length is no longer tracked. Commands unchanged; the re-pinned
digests of test_safety84/87 differ from bee7431 in OUTPUT_CLAMP rows only.
test_safety119 runs the rig's shape (meter in the same cycle) at 1-15 s
and checks a stop keeps the budget (review F2, X3).
Co-Authored-By: Claude <noreply@anthropic.com>
The quarter-edge numbers were measured with one cycle per reading at a
steady interval. With the default 15 s cycle floor, a meter that is
sometimes slower adds cycles on an old reading and the false alarm can
come back (reviewer's runs, 11 seeds). Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
No single rolling budget met both cases in the sweep (8 false-alarmed on
2 s seed 25 and warned in 1 to 3 of 7 quarters at 15 s). The budget is
now 10 cycles up to a 3.5 s cycle, 8 up to 11 s, 6 up to 16 s, 4 beyond,
per rolling 15 minutes; 8 while the cycle length is unknown. A stop or a
gap over two minutes is not a cycle length. The unsourced "owner
accepted N=8" paragraph is removed from DECISIONS. test_safety119 part 4
now runs 2 s seed 25 and shows a fixed budget of 8 warns there; the
never case runs at 2 s and checks every other quarter at 15 s.
Co-Authored-By: Claude <noreply@anthropic.com>
The rolling budget now holds without a monotonic clock (it never refills).
Quarter-edge tests use seeds 1-3 at 2, 5, 10 and 15 s (no hand-picked seeds).
Re-pin comments point at part 6. DECISIONS lists the limits the owner
accepted with N=8 on 2026-10-20.
Co-Authored-By: Claude <noreply@anthropic.com>
At most 8 hidden bound cycles in any 900 s across all hand-backs, replacing
the per-run budget. Chosen from a sweep (N 3 to 10, 1 to 15 s meters, both
cases); DECISIONS has the table. Tests: never case at 5, 10, 15 s, quarter
edge at 2, 10, 15 s, the rolling budget at its boundaries.
Co-Authored-By: Claude <noreply@anthropic.com>
A hand-back used to restart the window, so a guard and a charge taking
turns hid the loop's integrator bound for good (0 warnings in 2 h; 28
before the fix). A run of hand-backs (the wire away less than a settle
between them) now hides the bound for at most 11 bound cycles and 22 s in
all, then it counts. The quarter-edge kick stays hidden. No command or text
changes. Tests for the two reviewer mutants that only unit checks caught
(a restart counted as a hand-back; span only), DECISIONS gives the delay at
2 s, 5 s and 60 s. test_safety87.py:543 shortened.
Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The delay is 11 cycles, so up to 11 min at a 60 s cycle. A loop that loses
the wire again within 11 cycles is never counted; review measured one such
case (N=2, cheap-window charge, no forecast, house just over the rating).
The over-rating rule applies on cycles the loop decided. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
The re-pinned digests differ only in OUTPUT_CLAMP log rows; every command
and claim is the same as without the fix (test_safety119.py part 5).
DECISIONS: the delay at a 5 s meter and the open swap case.
Co-Authored-By: Claude <noreply@anthropic.com>
When the peak guard or a maintenance charge hands the wire back, the loop's
integrator is re-seeded from that owner's command and kicked by a meter that
does not show it yet. It crossed its rail for a cycle or two and raised
goodwe_integrator_bound while the battery gave what it was told.
The loop's integrator bound is not counted until the plant's settle
(SHORT_CYCLES, SHORT_SPAN_S) has passed since the hand-back. An over-rating
always counts; a bound that lasts warns after the settle. No command
changes and no text changes. test_safety119.py; DECISIONS entry.
Co-Authored-By: Claude <noreply@anthropic.com>
With 15-minute prices the chart now has one bar per quarter (92/96/100),
not hour averages; hourly and static tariffs still draw one bar per hour.
Cheap and dear marks come from the kept priceruns result (battery modes
on) or the arbitrage verdict's two points (off), not a thirds split.
A missing quarter is an empty bar. Removes plan.average_tip (EN/NL).
Co-Authored-By: Claude <noreply@anthropic.com>
README and FIELD-GUIDE.md said the PDF was not rebuilt; it was, on
2026-10-17. Its content is still v0.1.0 and outdated. Rewrap the
DOCS.md intro line. Text only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Both digests hash the discovery payloads, which carry the manufacturer.
Values regenerated; nothing else changes.
Co-Authored-By: Claude <noreply@anthropic.com>
Device id (identifiers) is unchanged; only the display text moves.
test_mqtt baseline updated for that one string.
Co-Authored-By: Claude <noreply@anthropic.com>
The add-on is wired to the inverter's RS485 port labelled EMS. Reword
README, DOCS, config description, field guide source and HTML. The HA
manufacturer string is left unchanged: test_mqtt pins it byte for byte.
Co-Authored-By: Claude <noreply@anthropic.com>
Review of PR #199. "Warns once" left out the Home row and the Settings
note, which stay while the fault lasts. "No option change" now points to
the one case that needs a look.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>