SAFETY-135: a young 15-minute period does not cost the night charge the whole period
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.

DECISIONS/SAFETY-135-young-period.md, test_safety135.py.