OPT-09: the weights parameter nothing ever passed, and what it cannot do #62
@@ -267,6 +267,35 @@ the conclusion is unchanged and is now stated on the predicate's own inputs.
|
||||
hazard from opposite sides: **OPT-09 stops the site ASKING a pack whose SoC says
|
||||
it cannot deliver; SAFETY-42 alarms when a pack that said it could does not.**
|
||||
|
||||
⚠️ **AND THIS CARD NARROWS SAFETY-42's DETECTION WINDOW. IT IS A DETECTION
|
||||
REGRESSION AT TWO INVERTERS AND IT IS DISCLOSED RATHER THAN FIXED.** An earlier
|
||||
draft of this entry and of `DECISIONS/OPT-09-soc-aware-weights.md` §5 said a
|
||||
wedged unit's weight does not move, so OPT-09 could not see the case at all. The
|
||||
ENVELOPE half is true - a wedged box reads a healthy SoC and nothing closes. The
|
||||
WEIGHT half was **false**: a weight is a function of a pack's ENERGY HEADROOM,
|
||||
not of what the pack delivers, so a wedged unit's weight moves whenever its
|
||||
headroom differs from its sibling's. And `delivery.delinquent()` names a unit
|
||||
only while its shortfall exceeds `saturation_w` - **500 W in absolute watts** -
|
||||
so shrinking the share shrinks the gap below the threshold and the alarm stops
|
||||
firing. Measured end to end with the real loop, the real allocator and the real
|
||||
detector, on a unit wedged at a healthy 15 % against its own 10 % floor (a
|
||||
SAFETY-42 true positive by that card's own definition): at a 1500 W load the
|
||||
healthy pack can carry alone, equal weights name it on **199 of 200** cycles and
|
||||
these weights name it on **none of the 200** - shares 1505/125, gap 125 W, and
|
||||
125 W is under the threshold. The suppression window widens from a site target
|
||||
below 1000 W to a site target below `saturation_w * (w_A + w_B) / w_B`, which on
|
||||
that fixture is **6500 W of a 9600 W site**; above it the healthy pack hits its
|
||||
own rating, the allocator's last-resort pass hands the wedged unit a big share
|
||||
again and the alarm returns. So in the quiet regime - where `unmet_w` is 0, the
|
||||
meter is satisfied and no action-log line fires - **a wedged inverter with less
|
||||
energy headroom than its sibling can now go unreported at ordinary house
|
||||
loads.** `test_packshare.py` part 8b grades it and pins the CURRENT behaviour, so
|
||||
the day it changes a named check moves. Closing it means making `delinquent()`
|
||||
relative to the ask rather than absolute, which is SAFETY-42's code and a design
|
||||
change; that is filed as its own card and is deliberately not done here.
|
||||
⚠️ Every two-unit figure above is **two copies of inverter A** through a modelled
|
||||
plant - inverter B does not exist yet - and B's ratings are datasheet and serial.
|
||||
|
||||
⚠️ **AN INVERTER THAT STOPS DELIVERING ITS SHARE IS NOW REPORTED BY NAME
|
||||
([[SAFETY-42]]) - AND THIS ADDS AN OPTION, SO IT IS A SCHEMA CHANGE.**
|
||||
`delivery_hold_s: 185` joins `options:` and `schema:` (`int(30,900)`). The
|
||||
|
||||
@@ -1,6 +1,8 @@
|
||||
# OPT-09 - the weights parameter, and what it is honestly for
|
||||
|
||||
**Status:** implemented. **Branch:** `OPT-09`. **Base:** `release/1.0` @ `464d398`.
|
||||
**Status:** implemented. **Branch:** `OPT-09`. **Base:** `release/1.0` @ `3368231`
|
||||
(`git merge-base HEAD 3368231`; the branch was rebased and this line used to name
|
||||
the pre-rebase base, `464d398`).
|
||||
|
||||
## 0. What was actually wrong
|
||||
|
||||
@@ -9,7 +11,7 @@ consumes it in two passes, and **nothing had ever passed one**. Confirmed on the
|
||||
base commit:
|
||||
|
||||
arbiter.py:535 def resolve(claims, *, units=None, weights=None, live=None, ...)
|
||||
main.py:2272 resolve(claims, units=self.units, live=self.live_units(), ...)
|
||||
main.py:2422 resolve(claims, units=self.units, live=self.live_units(), ...)
|
||||
|
||||
So `weights` was None on every tick of every install, `plan()` turned that into
|
||||
1.0 per unit, and the site target was split **50/50 regardless of what either
|
||||
@@ -147,16 +149,67 @@ deferred option, and the BMS is what stops it.
|
||||
|
||||
## 5. SAFETY-42 - the same hazard from the opposite side
|
||||
|
||||
They meet and do not overlap, and the seam is **the state of charge**:
|
||||
The seam is **the state of charge** - and they overlap in one direction, which
|
||||
is what the rest of this section is about:
|
||||
|
||||
* **OPT-09 stops the site ASKING** a pack whose own SoC says it cannot deliver.
|
||||
* **SAFETY-42 alarms** when a pack that said it could does not.
|
||||
|
||||
A wedged unit reads a healthy SoC, so no envelope closes and no weight moves -
|
||||
OPT-09 cannot see it at all. A pack at its floor is `account()`'s explained case,
|
||||
so SAFETY-42 stays silent - and after this card that ask does not arrive in the
|
||||
first place, which removes the benign arm from the detector's input rather than
|
||||
teaching it a new discriminator.
|
||||
A wedged unit reads a healthy SoC, so **no envelope closes** - that half is
|
||||
absolute, and it is why this card cannot stop the ask on a wedged box. A pack at
|
||||
its floor is `account()`'s explained case, so SAFETY-42 stays silent - and after
|
||||
this card that ask does not arrive in the first place, which removes the benign
|
||||
arm from the detector's input rather than teaching it a new discriminator.
|
||||
|
||||
⚠️ **BUT THE WEIGHT DOES MOVE, AND IT NARROWS SAFETY-42's DETECTION WINDOW. THIS
|
||||
IS A DETECTION REGRESSION AT N=2 AND IT IS NOT FIXED HERE.** An earlier draft of
|
||||
this section said "no envelope closes and no weight moves - OPT-09 cannot see it
|
||||
at all". The second clause was **false**, and it was load-bearing for the claim
|
||||
that the two cards do not overlap. A weight is a function of the pack's ENERGY
|
||||
HEADROOM, not of what the pack delivers, so a wedged unit's weight moves whenever
|
||||
its headroom differs from its sibling's - which is the ordinary case this card
|
||||
exists to exploit. And `delivery.delinquent()` (`app/delivery.py:484`)
|
||||
names a unit only while its `short_by()` gap exceeds `min_w =
|
||||
Tuning.saturation_w` - the comparison is `app/delivery.py:531`, and it is
|
||||
**500 W in absolute watts**. Shrinking a unit's share shrinks its gap. Shrink the
|
||||
share far enough and the gap drops below 500 W while the unit is still delivering
|
||||
nothing, and the alarm stops firing.
|
||||
|
||||
Measured on the closed loop - real `compute()`, real `plan()`, real
|
||||
`delinquent()`, modelled plant, B wedged at 15 % against its own 10 % floor so
|
||||
nothing closes and `account()` explains nothing, i.e. a SAFETY-42 **true
|
||||
positive** by that card's own definition:
|
||||
|
||||
load 1500 W equal weights (shipped) named on 199/200 cycles
|
||||
shares {a:1500, b:1500} grid +0 W named=['inverter-b']
|
||||
load 1500 W OPT-09 weights named on 0/200 cycles
|
||||
shares {a:1505, b: 125} grid -5 W named=(nobody)
|
||||
|
||||
⚠️ That plant is modelled in `test_packshare.py`, and **inverter B does not
|
||||
exist** (expected ~2026-09-12): it is two copies of A driven with different
|
||||
numbers, and B's 4600 W / 20.48 kWh / 10 % floor are from the datasheet and the
|
||||
serial. The claim is about the arithmetic of the split and the threshold, which
|
||||
needs no hardware, and not about a GW5000S-BP.
|
||||
|
||||
At a load the healthy pack can cover - the regime where nothing else tells the
|
||||
operator anything, `unmet_w` is 0, the meter is satisfied and no action-log line
|
||||
fires - a wedged inverter goes from named on essentially every cycle to **never
|
||||
named**. The suppression window widens from `site target < 2 * min_w` = 1000 W to
|
||||
`site target < min_w * (w_A + w_B) / w_B`, which on that fixture is **6500 W** of
|
||||
a 9600 W site; above it - once the healthy pack is at its own rating and
|
||||
`_fill()`'s last-resort pass hands the wedged unit a big share again - the alarm
|
||||
returns. `test_packshare.py` part 8b grades all of it and **pins the current,
|
||||
unflattering behaviour**, so that the day it changes a named check moves.
|
||||
|
||||
So the seam, stated accurately: **OPT-09 stops the ask AND narrows SAFETY-42's
|
||||
detection window for a low-headroom unit.** The two cards do not merely meet from
|
||||
opposite sides; this one takes something away from the other one. Closing the gap
|
||||
means making `delinquent()` relative to the ask rather than absolute, which is
|
||||
SAFETY-42's code and a design change - it is filed as its own card, deliberately
|
||||
not done here, and this paragraph is its input. Until then this is a **disclosed
|
||||
residual**, in the same voice as SAFETY-13's "2 of 272" and SAFETY-42's own "the
|
||||
discriminator does not exist": at two inverters, a wedged unit with materially
|
||||
less energy headroom than its sibling can go unreported at ordinary house loads.
|
||||
|
||||
⚠️ **And OPT-09 supplies the mechanism SAFETY-42 said was missing, without
|
||||
connecting it.** That module's rejection of re-allocation rests on *"the only
|
||||
|
||||
@@ -234,9 +234,12 @@ single-inverter entity back in that field. **Before downgrading, write down the
|
||||
|
||||
#### How the site target is divided between the packs (OPT-09)
|
||||
|
||||
Two packs do not get half each. Since 0.7.x the split is driven by two separate
|
||||
things, and it is worth knowing which is which, because only one of them is a
|
||||
rule:
|
||||
Two packs do not get half each **from 0.8.0 onwards**. ⚠️ **On 0.7.0 and every
|
||||
version before it the split is a fixed 50/50 regardless of what either pack can
|
||||
do** — that is the defect this section describes the fix for, so if the add-on
|
||||
you are running reports 0.7.0, none of what follows is happening yet. From 0.8.0
|
||||
the split is driven by two separate things, and it is worth knowing which is
|
||||
which, because only one of them is a rule:
|
||||
|
||||
* **The envelope — a permission.** A pack whose own state of charge is at or
|
||||
under its own `bms_soc_floor` is **not asked to discharge**; a pack at 100 %
|
||||
|
||||
@@ -57,6 +57,37 @@ deliver DOES NOT SHIFT TO ITS SIBLING by any mechanism in this add-on.
|
||||
never rises. That module DETECTS it; this one cannot fix it, and saying so
|
||||
is worth more than a weighting scheme that looks like it might.
|
||||
|
||||
⚠️ AND IT IS WORSE THAN "CANNOT FIX IT": THESE WEIGHTS NARROW SAFETY-42's
|
||||
DETECTION WINDOW, WHICH IS A DETECTION REGRESSION AT N=2
|
||||
=======================================================================
|
||||
This module used to say - and `DECISIONS/OPT-09-soc-aware-weights.md` §5 said
|
||||
with it - that a wedged unit's weight does not move, so OPT-09 cannot see the
|
||||
case at all. THE ENVELOPE HALF IS TRUE: a wedged box reads a healthy SoC and
|
||||
nothing here closes. THE WEIGHT HALF WAS FALSE. `weights()` is a function of a
|
||||
pack's ENERGY HEADROOM, not of what the pack delivers, so a wedged unit's weight
|
||||
moves whenever its headroom differs from its sibling's - the ordinary case this
|
||||
module exists to exploit.
|
||||
|
||||
`delivery.delinquent()` names a unit only while its `short_by()` gap exceeds
|
||||
`min_w` (`Tuning.saturation_w`, 500 W) in ABSOLUTE WATTS. Shrinking a unit's
|
||||
share shrinks its gap. Measured end to end (`test_packshare.py` part 8b: real
|
||||
`compute()`, real `plan()`, real `delinquent()`, B wedged at 15 % against its
|
||||
own 10 % floor, so `envelope()` does not close and `account()` explains
|
||||
nothing): at a 1500 W load the healthy pack can carry alone, equal weights name
|
||||
the wedged unit on 199 of 200 cycles and these weights name it on NONE. The
|
||||
suppression window widens from `site target < 2 * min_w` = 1000 W to
|
||||
`site target < min_w * (w_A + w_B) / w_B` = 6500 W on that fixture - and it has
|
||||
an upper edge: past the healthy pack's own rating, `_fill()`'s last-resort pass
|
||||
hands the wedged unit a big share again and the alarm returns.
|
||||
|
||||
⚠️ SO THE SEAM IS NOT "OPT-09 CANNOT SEE IT". IT IS: OPT-09 STOPS THE ASK
|
||||
**AND** NARROWS SAFETY-42's DETECTION WINDOW FOR A LOW-HEADROOM UNIT. That
|
||||
is a disclosed residual, not a fixed thing. Closing it means making
|
||||
`delinquent()` relative to the ask rather than absolute - SAFETY-42's code
|
||||
and a design change, filed as its own card and deliberately NOT done here.
|
||||
Do not "fix" part 8b by making it assert the alarm still fires; it does not,
|
||||
and a green check that says otherwise would be worse than the gap.
|
||||
|
||||
WHY ENERGY AND NOT POWER
|
||||
========================
|
||||
The two packs at this site are asymmetric IN OPPOSITE DIRECTIONS. From the
|
||||
|
||||
@@ -41,6 +41,7 @@ from app.arbiter import (
|
||||
ACTUATOR_SITE, CLAIM_SCOPE, P_LOOP, P_SAFETY, SCOPE_UNIT, Claim, resolve,
|
||||
)
|
||||
from app.control import Tuning, compute
|
||||
from app.delivery import UnitDelivery, account, delinquent
|
||||
from app.peakguard import discharge_permitted
|
||||
|
||||
fails = []
|
||||
@@ -599,14 +600,168 @@ check("...so: WEIGHTS ARE A COMFORT CHOICE FOR STABILITY AND NOT FOR DELIVERY, "
|
||||
weights={A: 1.0, Bee: 0.0}).shares == {A: 2000, Bee: 1000})
|
||||
check("...and SAFETY-42 is where the case this card CANNOT reach is handled. A "
|
||||
"WEDGED unit - one that accepts its share and does not produce it - has a "
|
||||
"healthy state of charge, so no envelope closes and no weight moves; that "
|
||||
"module detects it, latches and notifies, and deliberately does not act. "
|
||||
"OPT-09 stops the site ASKING a pack whose own SoC says it cannot "
|
||||
"deliver; SAFETY-42 alarms when a pack that said it could does not. Same "
|
||||
"hazard, opposite sides, and the seam is the state of charge",
|
||||
"healthy state of charge, so NO ENVELOPE CLOSES; that module detects it, "
|
||||
"latches and notifies, and deliberately does not act. OPT-09 stops the "
|
||||
"site ASKING a pack whose own SoC says it cannot deliver; SAFETY-42 "
|
||||
"alarms when a pack that said it could does not. ⚠️ THE WEIGHT, HOWEVER, "
|
||||
"DOES MOVE - this check used to say it did not - and part 8b grades what "
|
||||
"that costs the alarm",
|
||||
not packshare.envelope(PE(Bee, 55.0, B_KWH)).binding)
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("8b. ⚠️ AND WHAT THE WEIGHTS DO TO SAFETY-42's DETECTION WINDOW, WHICH IS "
|
||||
"A REGRESSION AND IS PINNED HERE AS ONE")
|
||||
|
||||
# ⚠️ READ THIS BEFORE READING THE CHECKS: THEY ASSERT THE UNFLATTERING ANSWER ON
|
||||
# PURPOSE. An earlier draft of §5 of the decision said a wedged unit's weight
|
||||
# does not move, so OPT-09 "cannot see it at all". The first clause is about the
|
||||
# ENVELOPE and is true; the second is FALSE. A wedged unit's weight moves
|
||||
# whenever its energy headroom differs from its sibling's - it is a pack fact,
|
||||
# not a delivery fact - and `delivery.delinquent()` names a unit only while its
|
||||
# `short_by()` gap exceeds `min_w` (`Tuning.saturation_w`, 500 W) IN ABSOLUTE
|
||||
# WATTS. Shrinking a unit's share shrinks its gap. Shrink it below 500 W and the
|
||||
# alarm stops firing on a unit that is still delivering nothing.
|
||||
#
|
||||
# So the seam is not "OPT-09 cannot see it". It is: OPT-09 stops the ask AND
|
||||
# narrows SAFETY-42's detection window on the same unit. At equal weights the
|
||||
# window is `site target < 2 * min_w` = 1000 W; at OPT-09's weights it is
|
||||
# `site target < min_w * (w_A + w_B) / w_B`, which on this fixture is 6500 W.
|
||||
#
|
||||
# ⚠️ THIS IS A DETECTION REGRESSION AT N=2 AND IT IS NOT FIXED HERE. Making
|
||||
# `delinquent()` relative to the ask rather than absolute is SAFETY-42's code and
|
||||
# a design change; it is filed as its own card. What this part does is GRADE THE
|
||||
# CURRENT BEHAVIOUR so that the day it changes, a named check moves.
|
||||
#
|
||||
# ⚠️ AND THE FIXTURE IS A SAFETY-42 TRUE POSITIVE BY THAT CARD'S OWN DEFINITION,
|
||||
# checked below before anything is concluded from it: B is WEDGED - it accepts
|
||||
# its share and produces nothing - at a HEALTHY 15 % against its own 10 % floor,
|
||||
# so `envelope()` does not close and `account()` explains nothing. This is
|
||||
# exactly the case §5 says the envelope cannot reach, which is why it is the
|
||||
# case where the weights' side effect matters.
|
||||
#
|
||||
# ⚠️ TWO COPIES OF A. Inverter B does not exist; the plant below is modelled in
|
||||
# this file the way part 8's is, and B's ratings are datasheet.
|
||||
|
||||
WEDGED_A_SOC, WEDGED_B_SOC = 90.0, 15.0 # both healthy, both above their floor
|
||||
MIN_W = Tuning().saturation_w # what `delinquent()` is handed
|
||||
|
||||
|
||||
def wedged_loop(load_w, weighted, cycles=200):
|
||||
"""The closed loop with unit B WEDGED at a healthy SoC. Real everything.
|
||||
|
||||
Real `compute()`, real `plan()`, real `packshare.weights()`, real
|
||||
`delivery.account()` and real `delivery.delinquent()`. The only model is the
|
||||
plant: A obeys within one cycle inside its rating, B accepts whatever it is
|
||||
told and delivers 0 W - which is the wedged box, and is what makes this a
|
||||
SAFETY-42 case rather than an OPT-09 one.
|
||||
|
||||
`weighted=False` is equal weights - what shipped. Envelopes are left OPEN in
|
||||
both arms deliberately: neither pack's SoC closes one here, so filing them
|
||||
would change nothing and would blur which half of the card is being graded.
|
||||
|
||||
Returns `(cycles on which delinquent() named somebody, last cycle)`.
|
||||
"""
|
||||
packs = [PE(A, WEDGED_A_SOC, A_KWH), PE(Bee, WEDGED_B_SOC, B_KWH)]
|
||||
tuning = Tuning(gain=1.0, slew_w=1000.0, max_w=A_W + B_W)
|
||||
prev, i_w, sat = 0.0, None, 0
|
||||
power = [0.0, 0.0]
|
||||
grid = load_w
|
||||
named, last = 0, None
|
||||
for _c in range(cycles):
|
||||
d = compute(prev, grid, sum(power), tuning, sat, i_w)
|
||||
prev, i_w, sat = d.target_w, d.i_w, d.sat_count
|
||||
w = packshare.weights(packs, d.target_w) if weighted else None
|
||||
r = plan(d.target_w, {A: _B(-A_W, A_W), Bee: _B(-B_W, B_W)}, weights=w)
|
||||
assert r.ok, r.refused
|
||||
# THE MODELLED PLANT: A within one cycle inside its rating; B WEDGED.
|
||||
power = [max(-A_W, min(A_W, float(r.shares[A]))), 0.0]
|
||||
grid = load_w - sum(power)
|
||||
who = delinquent(
|
||||
[UnitDelivery(p.name, r.shares[p.name], m,
|
||||
account(live=True, parked=False, soc=p.soc,
|
||||
bms_floor=p.bms_floor))
|
||||
for p, m in zip(packs, power)], MIN_W)
|
||||
named += bool(who)
|
||||
last = (d.target_w, dict(r.shares), grid, who)
|
||||
return named, last
|
||||
|
||||
|
||||
_WEDGED_PACK = PE(Bee, WEDGED_B_SOC, B_KWH)
|
||||
check("PRECONDITION: the wedged unit is a SAFETY-42 TRUE POSITIVE and NOT an "
|
||||
"OPT-09 case - at 15 % against its own 10 % floor no envelope closes and "
|
||||
"`account()` explains nothing, so anything the weights do to the alarm "
|
||||
"here is done to a fault the operator is entitled to be told about",
|
||||
not packshare.envelope(_WEDGED_PACK).binding
|
||||
and account(live=True, parked=False, soc=WEDGED_B_SOC,
|
||||
bms_floor=FLOOR) is None)
|
||||
|
||||
_wedge = {}
|
||||
for _load in (1500.0, 6000.0):
|
||||
for _weighted in (False, True):
|
||||
_n, _t = wedged_loop(_load, _weighted)
|
||||
_wedge[(_load, _weighted)] = (_n, _t)
|
||||
print(f" load {_load:.0f} W, B wedged at 15 %, "
|
||||
f"{'OPT-09 weights' if _weighted else 'equal weights ':<14} "
|
||||
f"named on {_n:3d}/200 cycles, site target {_t[0]:+.0f} W, shares "
|
||||
+ ", ".join(f"{u}{v:+d}" for u, v in sorted(_t[1].items()))
|
||||
+ f", grid {_t[2]:+.0f} W, named="
|
||||
+ (str(sorted(_t[3])) if _t[3] else "(nobody)"))
|
||||
|
||||
check("AT EQUAL WEIGHTS - WHAT SHIPPED - the wedged unit is named on every "
|
||||
"cycle but the first, at a load its sibling can carry on its own. The "
|
||||
"loop winds the site target to twice the load, the 50/50 split stands "
|
||||
"+1500 W on a box producing nothing, and 1500 W > 500 W is what "
|
||||
"`delinquent()` reads",
|
||||
_wedge[(1500.0, False)][0] == 199
|
||||
and sorted(_wedge[(1500.0, False)][1][3]) == [Bee]
|
||||
and _wedge[(1500.0, False)][1][1] == {A: 1500, Bee: 1500})
|
||||
|
||||
check("⚠️ AND WITH OPT-09's WEIGHTS IT IS NAMED ON NONE OF THE 200. Same wedged "
|
||||
"box, same healthy SoC, same load, same detector: the split moves to "
|
||||
"1505/125, the gap on the wedged unit falls to 125 W, and 125 W < 500 W "
|
||||
"so `delinquent()` returns {}. THIS CHECK PINS A REGRESSION - it asserts "
|
||||
"what the code DOES, not what anyone wants, and if it ever goes red "
|
||||
"because the alarm fired, read the card that made it fire before "
|
||||
"'fixing' this line",
|
||||
_wedge[(1500.0, True)][0] == 0
|
||||
and _wedge[(1500.0, True)][1][3] == {}
|
||||
and _wedge[(1500.0, True)][1][1] == {A: 1505, Bee: 125})
|
||||
|
||||
check("...and this is the regime where NOTHING ELSE TELLS THE OPERATOR "
|
||||
"ANYTHING: the meter is satisfied (grid within 5 W of zero), `unmet_w` is "
|
||||
"0 because both units accepted their shares, no envelope closed and no "
|
||||
"action-log line fires. The site is quietly running one inverter and the "
|
||||
"one instrument built to say so has gone quiet with it",
|
||||
abs(_wedge[(1500.0, True)][1][2]) <= 5.0
|
||||
and abs(_wedge[(1500.0, False)][1][2]) <= 5.0)
|
||||
|
||||
_w = packshare.weights([PE(A, WEDGED_A_SOC, A_KWH), _WEDGED_PACK], 1000.0)
|
||||
_window_equal = MIN_W * 2.0
|
||||
_window_opt09 = MIN_W * sum(_w.values()) / _w[Bee]
|
||||
print(f" suppression window on this fixture: equal weights, site target "
|
||||
f"< {_window_equal:.0f} W; OPT-09 weights, site target "
|
||||
f"< {_window_opt09:.0f} W of a {A_W + B_W:.0f} W site")
|
||||
check("...and the arithmetic behind it, stated as a window rather than as one "
|
||||
"fixture: `delinquent()` reads an ABSOLUTE gap, so a unit weighted to a "
|
||||
"fraction f of the site target is invisible while `f * target < min_w`. "
|
||||
"Equal weights suppress below 1000 W; these weights suppress below "
|
||||
"6500 W of a 9600 W site. That is the regression, and it is a property "
|
||||
"of the threshold being absolute rather than of any number chosen here",
|
||||
abs(_window_equal - 1000.0) < 1.0 and abs(_window_opt09 - 6500.0) < 1.0)
|
||||
|
||||
check("⚠️ AND IT IS NOT THAT THE WEIGHTED ARM NEVER NAMES ANYBODY - which is "
|
||||
"what a check that only ever ran the quiet load would be pinning. Push "
|
||||
"the load past the healthy pack's OWN RATING and `_fill()`'s last-resort "
|
||||
"pass hands the wedged unit 3000 W anyway, the gap goes back over 500 W, "
|
||||
"and BOTH arms name it. The window is real and it has an upper edge; the "
|
||||
"hole is the quiet regime below that edge",
|
||||
_wedge[(6000.0, True)][0] == 195
|
||||
and sorted(_wedge[(6000.0, True)][1][3]) == [Bee]
|
||||
and _wedge[(6000.0, False)][0] == 199
|
||||
and sorted(_wedge[(6000.0, False)][1][3]) == [Bee])
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("9. PER-PACK ARBITRAGE SIZING")
|
||||
@@ -814,8 +969,12 @@ print(" policy; `arbitrage_soc_ceiling` is a trade preference and using")
|
||||
print(" it here would be SAFETY-25's deferred option in the charge")
|
||||
print(" direction. Everything between is left to the weights, which are")
|
||||
print(" a preference and are honest about being one.")
|
||||
print(" * A WEDGED UNIT IS NOT REACHABLE FROM HERE AT ALL. Its SoC reads")
|
||||
print(" healthy, so no envelope closes. SAFETY-42 owns it.")
|
||||
print(" * A WEDGED UNIT IS NOT REACHABLE BY THE ENVELOPE. Its SoC reads")
|
||||
print(" healthy, so nothing closes, and SAFETY-42 owns the detection.")
|
||||
print(" ⚠️ BUT IT IS REACHABLE BY THE WEIGHTS, WHICH MOVE ON ENERGY")
|
||||
print(" HEADROOM AND NOT ON DELIVERY - part 8b grades what that does")
|
||||
print(" to SAFETY-42's window, and the answer is a REGRESSION that is")
|
||||
print(" pinned rather than fixed.")
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
@@ -856,6 +1015,15 @@ MUT = [
|
||||
"test_packshare 1's PRECONDITION. ⚠️ IT WAS A TRACEBACK BEFORE THAT LINE "
|
||||
"EXISTED - the first draft of this file had no precondition and the "
|
||||
"mutation took it down with a TypeError three lines into part 1"),
|
||||
("M11 weights(): keep the shape, force every weight to 1.0 <- THE PROOF "
|
||||
"THAT PART 8b CAN GO RED",
|
||||
"test_packshare 8b, three named checks: the wedged unit goes back to being "
|
||||
"named on 199/200 at 1500 W, the split reverts to 1500/1500 and the "
|
||||
"window collapses from 6500 W to 1000 W. ⚠️ RUN, NOT REASONED ABOUT - a "
|
||||
"check that pins an UNFLATTERING behaviour has to be shown capable of "
|
||||
"failing, or it is indistinguishable from a check that pins nothing. "
|
||||
"(It also takes parts 1, 3, 7 and 8 down, which is M3's territory; 8b is "
|
||||
"the part that names the SAFETY-42 interaction)"),
|
||||
]
|
||||
for _n, _w in MUT:
|
||||
print(f" caught {_n}")
|
||||
@@ -866,7 +1034,7 @@ check("every mutation in the table above was RUN and every one of them is "
|
||||
"invisible to every behavioural fixture in this repository, because they "
|
||||
"all build their own claim list and call `resolve()` themselves. That is "
|
||||
"why the call site is pinned statically as well",
|
||||
len(MUT) == 10)
|
||||
len(MUT) == 11)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
|
||||
Reference in New Issue
Block a user