Deploy 0.15.0 to master #174

Merged
admin merged 13 commits from deploy-0.15.0 into master 2026-10-05 10:17:39 +02:00
Owner

Ships release 0.15.0 (3ed3302, merged via #173) to master, which Home Assistant installs from.

Owner go: 2026-10-05 ("Go deploy").

  • Pinned to 3ed3302 through the branch deploy-0.15.0.
  • predeploy_check.py --deployed-version 0.14.0 with a fresh export of the live options (two-inverter roster, Watchdog on): see the deploy report.
  • Changelog: ## 0.15.0 in goodwe_controller/CHANGELOG.md (SAFETY-94, SAFETY-97, SAFETY-58; CI-14).

🤖 Generated with Claude Code

Ships release 0.15.0 (`3ed3302`, merged via #173) to `master`, which Home Assistant installs from. Owner go: 2026-10-05 ("Go deploy"). - Pinned to `3ed3302` through the branch `deploy-0.15.0`. - `predeploy_check.py --deployed-version 0.14.0` with a fresh export of the live options (two-inverter roster, Watchdog on): see the deploy report. - Changelog: `## 0.15.0` in `goodwe_controller/CHANGELOG.md` (SAFETY-94, SAFETY-97, SAFETY-58; CI-14). 🤖 Generated with [Claude Code](https://claude.com/claude-code)
admin added 13 commits 2026-10-05 09:48:16 +02:00
SAFETY-94: a healthy battery that lags or reverses is not flagged as frozen or refusing
checks / unit (pull_request) Successful in 28m10s
infra-pin / fresh (pull_request) Failing after 2s
6759d21ea5
The stale-reading gate counted its 35 s from the register's last change, so
after a rest the first read after a new command tripped it (SAFETY-58; live
2026-10-03, four trips 1 s after the command). It now counts only the time
the command asked the register to move.

At N=1 the refusal engaged after 12 frozen cycles if the reading was under
100 W at that moment, which a battery reversing through its lag passes at a
1 s meter. The refusal now needs the N>1 evidence at every roster size: under
100 W, one way, for 12 cycles spanning 22 s, restarting when the reading
moves 50 W towards the ask.

DECISIONS/SAFETY-94-lagging-battery.md; test_safety94.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-94 review: tests for three surviving mutants; record two gaps
checks / unit (pull_request) Successful in 28m7s
infra-pin / fresh (pull_request) Failing after 2s
dd5eb6fdc8
- test_safety94 part 4: time under 250 W is not counted; a command that
  swaps direction every cycle is never refusal evidence; a reading moving
  away from the ask does not restart the evidence. These kill review
  mutants R1, R3 and R6, which survived the PR's tests.
- DECISIONS: at N=1 a battery with B's standby offset no longer latches
  a refusal (SAFETY-97 now covers N=1); a part-time ask is caught after
  35/d s of wall time.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-97: "gives nothing" is graded against each battery's idle reading
checks / unit (pull_request) Failing after 29m7s
infra-pin / fresh (pull_request) Failing after 2s
6918e154c8
B's power reading shows -95 to -118 W at idle (standby draw), so the
|reading| < 100 W refusal band never held a refusing B: never at N=2,
and since SAFETY-94's shared rule not at N=1 either (review F1).

Each unit now learns its idle reading (app/idle.py): only while control
runs, the unit is not refused/stale/tripped and its command has stayed
within 50 W for 120 s; first value a 120 s mean, then a 30 min follow;
samples beyond 250 W dropped, value clamped to 250 W; saved per unit and
restored. The shared refusal evidence, compute()'s N=1 engage and end,
the unit refusal ends, the stale-path refusal and SAFETY-42's "parked"
test are centred on it. Until learned it is 0 W, the rule as it was.

Refusing B caught at N=1 28/28/65 s and N=2 24/24/60 s (1/2/5 s
meters), before never; refusing A unchanged. Healthy B with its offset,
SAFETY-94's scenarios, 96 runs: 0 stale, 0 refused. Live replay: 0.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
SAFETY-97: point test_safety97 at MUTATION.md; record the DC-entity option
checks / unit (pull_request) Successful in 29m9s
infra-pin / fresh (pull_request) Failing after 1s
80bfc5721e
test_bytecode requires every suite to name MUTATION.md (CI run 1158).
DECISIONS: why the integration's DC battery power entity is not the fix.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
SAFETY-97: test the centred stale-path refusal (mutant S10 survived)
checks / unit (pull_request) Successful in 29m7s
infra-pin / fresh (pull_request) Failing after 1s
3db2b6392f
At a 5 s meter a register frozen at rest on B trips the stale gate before
the 12-cycle evidence; its refusal must be centred on B's idle reading,
or the site stops and re-trips instead of refusing B.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
SAFETY-97 review: tests for four surviving mutants
checks / unit (pull_request) Successful in 28m57s
infra-pin / fresh (pull_request) Failing after 2s
88ebf3a5a6
The N=1 stale-path refusal and SAFETY-42's parked test are centred on the
idle reading; learning stops while control is stopped or the sign watchdog
has latched. Each had no check (review mutants X7, X8, X13, X14).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
SAFETY-97: centre the band on the idle reading clamped to 75 W
checks / unit (pull_request) Successful in 29m26s
infra-pin / fresh (pull_request) Failing after 2s
7d06aa674d
Owner decision 2026-10-04 (review R1). A wrong idle reading more than
about 100 W off hid every refusal on that battery. Clamped under the band,
the band keeps 0 W +-25 W, so a battery reading about 0 W while refusing is
caught whatever was learned or restored. Samples are still taken to 250 W.
Beyond about +-170 W of idle a battery behaves as in 0.14.0.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
CI-14: infra-pin to admin/goodwe 3b4ff84 (WITNESS-09)
checks / unit (pull_request) Successful in 29m18s
infra-pin / fresh (pull_request) Successful in 1s
64dddd64bf
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Release 0.15.0: bump version and close the CHANGELOG section
checks / unit (pull_request) Successful in 29m1s
infra-pin / fresh (pull_request) Successful in 1s
f01152b113
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from
SAFETY-94/97, no option change). New `## 0.15.0` section with the contents
since 0.14.0 (cf705a9 #171, 3129dae #172) and the known issues.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Release 0.15.0: correct the SAFETY-94/97 row, add the ±170 W known issue
checks / unit (pull_request) Successful in 29m6s
infra-pin / fresh (pull_request) Successful in 1s
8c6e5bca2e
Review round 1 (F1-F3) on PR #173.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Merge pull request 'Release 0.15.0' (#173) from release-0.15.0 into release/1.0
infra-pin / fresh (push) Successful in 1s
checks / unit (pull_request) Successful in 29m8s
infra-pin / fresh (pull_request) Successful in 1s
3ed3302d2f
Release 0.15.0 (#173)
admin merged commit 21599938ea into master 2026-10-05 10:17:39 +02:00
Sign in to join this conversation.
No Reviewers
No labels
1 Participants
Notifications
Due Date
No due date set.
Dependencies

No dependencies set.

Reference: admin/goodwe-addon#174