@@ -1,5 +1,49 @@
|
||||
# Changelog
|
||||
|
||||
## 0.16.0
|
||||
|
||||
**A minor bump: changed behaviour, no option added or removed, and one default
|
||||
and its meaning changed.** There are still 83 options. `maintenance_start_hour`
|
||||
used to be read as UTC and its default was 10. It is now a local hour (in Home
|
||||
Assistant's time zone) and its default is 19. The other changes below apply
|
||||
with one inverter or two, unless a line says "Two inverters".
|
||||
|
||||
**Before you update (MAINT-10).** A saved `maintenance_start_hour` is kept, and
|
||||
it now means local time. If you set it in UTC to get an evening start (for
|
||||
example 17 for 19:00 in summer), set it back to the local hour (19). A saved
|
||||
10 now starts at 10:00, not 12:00 in summer. The new default 19 only reaches
|
||||
installs that have no hour saved.
|
||||
|
||||
Contents of this release, in merge order since 0.15.0 (`3ed3302`):
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `7ef7347` | After a gap in the P1 meter, the peak guard counts the missed time as high use and keeps the 15-minute period near the limit; before, it was blind until the next period. In the test, a 5 min meter silence at one inverter ended the period at 3.3 kW, against 4.8 kW on 0.15.0 ([[SAFETY-90]]) |
|
||||
| `1bf6b7f` | The maintenance start hour is now a local hour, and its default is 19 (was 10, read as UTC). The log says which time zone it used; with two inverters, both use that hour and still cycle one at a time ([[MAINT-10]]) |
|
||||
| `b2f5573` | Two inverters: when one battery's link drops, the other takes over in small steps, and control no longer stalls. The battery that comes back rejoins within 2 s, without a false "battery refuses" ([[SAFETY-96]]) |
|
||||
| `340c7ee` | Two inverters: when a drain ends (done, switched Off, timeout, lost link), the other battery covers the house right away, without jumping to 1.6 kW, and then moves in small steps. It no longer gives into a solar surplus ([[SAFETY-95]]) |
|
||||
|
||||
### Known issues
|
||||
|
||||
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
|
||||
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
|
||||
- A battery whose reading at rest is beyond about ±170 W is still not caught when it refuses, as in 0.14.0 ([[SAFETY-97]]).
|
||||
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s ([[SAFETY-99]]).
|
||||
- A charge to 100 % can time out at 98 %. The add-on then counts the cycle as failed and drains the battery again the next day ([[MAINT-13]]).
|
||||
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
|
||||
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
|
||||
- Two inverters: after a drain ends, the other battery can swing by about 800 W for about 5 s, because some readings are old ([[SAFETY-103]]).
|
||||
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
|
||||
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
|
||||
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
|
||||
|
||||
### If you are crossing from a version older than 0.10.0
|
||||
|
||||
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
|
||||
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
|
||||
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
|
||||
bare options (`jq '.data.options'`) first.
|
||||
|
||||
## 0.15.0
|
||||
|
||||
**A minor bump: changed behaviour, and no option changes.** No option was
|
||||
|
||||
@@ -0,0 +1,109 @@
|
||||
# MAINT-13 - a full pack that stops at 98-99 % is not a failed charge
|
||||
|
||||
**Status: for review.** Tests: `test_maint13.py`. No option added; every number
|
||||
is a constant in `app/maintenance.py`.
|
||||
|
||||
**What happened (live, B).** The drain ended 2026-10-04 18:24 UTC and the charge
|
||||
began. It ran in pieces behind the price gate, reached 99 % at 2026-10-06 04:00,
|
||||
fell back to 98 % at 04:15 while the loop still asked about -1370 W, and never
|
||||
reached `maintenance_soc_target` 100. At 06:24 (2160 min = 36 h of wall clock
|
||||
after the charge began) it aborted "charge stuck at 98 %". `last_completed` was
|
||||
not set, so B was still due and would have drained again from 98 % to 11 % at the
|
||||
next start hour, with no notice. Three faults: a pack may never report 100 %
|
||||
while the BMS balances; a failed cycle came back the next day; and the 36 h
|
||||
counted hours the price gate kept the pack waiting.
|
||||
|
||||
## 1. The charge is complete when
|
||||
|
||||
1. SoC >= target (as before), or
|
||||
2. SoC >= target - 3 (`CHARGE_NEAR_FULL_PCT`) and the SoC has not beaten its
|
||||
best for 60 min (`CHARGE_STALL_MIN`) of allowed charging, or
|
||||
3. the charging time (`CHARGE_TIMEOUT_MIN`, 2160 min) runs out at SoC >= target - 3.
|
||||
|
||||
Then the usual HOLD follows and `last_completed` is set after it. Each of 2 and
|
||||
3 logs one plain line ("the battery takes no more charge at 98 %, so the charge
|
||||
counts as done", "charge time is up at 98 %, close enough to full ...").
|
||||
|
||||
**Why "SoC has not beaten its best", and not asked/delivered watts.** SoC is the
|
||||
one signal the live record gives us (99 at 04:00, 98 at 04:15); the asked power
|
||||
was -1370 W but no delivered figure was kept, so a watt threshold (X, Y) would be
|
||||
invented. SoC also covers the case where power flows but nothing is stored.
|
||||
**Why 3 points.** The card's band; at target 100 it is 97, and the live pack sat
|
||||
at 98-99. **Why 60 min.** A judgement, not a measurement: we have no per-minute record of
|
||||
the pack taking charge near full. The one live fact is 2 h 24 min (04:00 to
|
||||
06:24) without a new high, so 60 min is well inside it and long enough that a
|
||||
pack still creeping up (one new high within the hour) keeps resetting the wait.
|
||||
On the live run the rule fires after 60 gate-open minutes past the 99 %: 05:00
|
||||
UTC at the earliest, before 06:24 if the gate was open. If the pack turns out to
|
||||
step up more slowly than that, raise the constant. Falling back by one point
|
||||
does not reset the wait; only a new best does.
|
||||
|
||||
## 2. A failed cycle backs off 7 days
|
||||
|
||||
A drain stuck 12 h or a charge that times out below target - 3 is a failure
|
||||
(`FAIL_BACKOFF_DAYS` = 7). The machine goes IDLE as before, `last_failed` is
|
||||
stored, and `wants_start()` is false until 7 days later. The operator's forced
|
||||
start ignores it; a cycle that completes after the failure ends it. An operator
|
||||
abort, an interlock stop and a switched-off pack are not failures.
|
||||
|
||||
**Why 7 days, not the 28 day interval.** A judgement: a failure may have a
|
||||
short cause (several dull days with no cheap hours, a pack switched off), and
|
||||
waiting the full interval leaves the coulomb counter uncalibrated for a month
|
||||
more. A week is long enough that a bad pack costs one drain a week, with one
|
||||
notice a week, not one a day. **Cost.** A truly faulty pack still drains once a week until someone looks;
|
||||
the notice says so each time.
|
||||
|
||||
**Notice, once.** The tick that fails carries `failed`; the Controller sends one
|
||||
persistent notification "Battery cycle did not finish" (EN, with the Dutch
|
||||
below it; per pack at N=2). It is not repeated, and Home Assistant restarts
|
||||
wipe it, so the status page shows a "Maintenance paused" row with the date for
|
||||
as long as the wait lasts. The operator may also see the log lines.
|
||||
|
||||
## 3. The timeout counts only allowed time
|
||||
|
||||
`Controller._charge_gate_open()` says whether the pack may charge now. It is
|
||||
true when no price gate is set up (no price entities, no fixed tariff: nothing
|
||||
holds the charge back, and `cheap` is always false there), in a cheap window, or
|
||||
while the pack is really taking charge (battery power at or below -50 W, which is
|
||||
sun outside cheap hours). It is false only when a gate exists, is shut, and the
|
||||
pack is not charging; a pack asked for charge that delivers nothing then does not
|
||||
count, which is the case the clock cannot judge. A site with a price provider
|
||||
(TARIFF-11) and no fixed tariff counts as having no gate: the provider's plan
|
||||
reaches only the Tariff row, never `cheap`, so no cheap window ever opens a grid
|
||||
top-up there and only the sun charges the pack, as on a site with no tariff. Its
|
||||
time counts in full. When a provider plan starts to drive `cheap`,
|
||||
`_price_gated` must become true for it. Whether a fixed tariff is set up is
|
||||
worked out once an hour, not on every tick. Only open ticks add to `open_min`; one tick
|
||||
adds at most 5 min, so a gap (add-on down) adds nothing. The stall wait pauses
|
||||
while the gate is closed. The accounting is written to the state file at most
|
||||
every 5 min (`charge_track`); a restart loses at most that. A state file from
|
||||
before this change, or with no record for the current charge, starts from the
|
||||
wall-clock minutes so far, which is the old behaviour.
|
||||
|
||||
**Backstop.** A gated site whose gate never opens (no cheap hours, no sun) would never time
|
||||
out, so a charge also ends after 7 days of wall clock (`CHARGE_WALL_TIMEOUT_MIN`):
|
||||
complete at >= target - 3, a failure below.
|
||||
|
||||
**MAINT-12.** This is the smallest change that makes the timeout honest: one
|
||||
boolean in, one counter. MAINT-12's block plan can replace the boolean (the
|
||||
minutes it plans are the allowed ones) without touching the rest. Two things it
|
||||
must keep: the back-off is in `wants_start()`, so any new entry point (such as
|
||||
`price_forecast.begin_phase`, which is not wired today) must go through it or
|
||||
check `backoff_until()`; and `gate_open` must stay "the pack is allowed to
|
||||
charge now". The peak guard pausing the charge shaping is not seen as a closed
|
||||
gate: that time still counts.
|
||||
|
||||
## 4. What does not change, and what this does not cover
|
||||
|
||||
- The drain, the HOLD, the held-battery rules and `arbitrate()` are unchanged. A
|
||||
backed-off pack does not want a start, so at N=2 the other pack may take the
|
||||
slot. One pack at a time at N=1 and N=2.
|
||||
- `last_failed` is a maintenance key and moves with the others when a second
|
||||
inverter is added (`MAINT_UNIT_KEYS`). The charge record is not moved; it
|
||||
restarts from the wall-clock minutes.
|
||||
- It does not find out why a pack stopped. A pack that stops at 96 % and never
|
||||
gets near is still a failure.
|
||||
- The Dutch text is only in the notification. The status row and the log lines
|
||||
are English, like the rest of the status page.
|
||||
- It does not change the target: a site that wants a different stop point sets
|
||||
`maintenance_soc_target`.
|
||||
@@ -0,0 +1,71 @@
|
||||
# MAINT-14 - no SoC reading in a maintenance cycle
|
||||
|
||||
**Status: for review.** Tests: `test_maint14.py`. No option added; the one new
|
||||
number is a constant in `app/maintenance.py`.
|
||||
|
||||
**The fault.** `Maintenance.tick()` returned early when the SoC was `None`,
|
||||
before any timeout check. (1) A charge on a pack whose SoC reading was lost
|
||||
never ended: no timeout, no back-off, no notice, and the 7-day backstop of
|
||||
MAINT-13 sat behind the same return. (2) A drain kept commanding `discharge_w`
|
||||
with an unknown level, which breaks the TEL-08 rule that an unknown level never
|
||||
allows discharge.
|
||||
|
||||
## Rules
|
||||
|
||||
1. **Charge, no SoC.** The charge timeout (`CHARGE_TIMEOUT_MIN`, gate-open
|
||||
minutes) and the 7-day wall backstop still run. When one fires: if the last
|
||||
SoC seen was >= target - 3 the charge counts as done (the MAINT-13 "close
|
||||
enough to full" rule, HOLD follows); otherwise it fails: MAINT-13 back-off
|
||||
and its one notification. If no SoC was ever seen, it fails.
|
||||
2. **Drain, no SoC.** DRAIN holds at 0 W and owns the setpoint, exactly as HOLD
|
||||
does. The 12 h drain timeout still runs and fails as before.
|
||||
3. **SoC comes back.** Nothing is recorded; the drain continues at the drain
|
||||
rate, the charge carries on, and the stall wait of MAINT-13 restarts from
|
||||
what it was: it paused while the reading was missing, so a gap never counts
|
||||
as "no more charge".
|
||||
4. **HOLD** is unchanged (0 W).
|
||||
5. **Log.** One line when a drain starts holding for this reason ("the battery
|
||||
level is unknown, so the drain holds at 0 W until it is back"), and one line
|
||||
when the level has been missing for `NOSOC_NOTE_MIN` = 15 min. Both are said
|
||||
once per episode; the old line that repeated every tick is gone.
|
||||
|
||||
## Why
|
||||
|
||||
- **"Last seen", not "best seen".** A pack that was at 99 and then dropped to 50
|
||||
before the reading went is not close to full. Only the last reading counts.
|
||||
It is saved with the charge record (`charge_track.last`), and saved at once
|
||||
when the reading first goes missing, so a restart mid-gap still knows it
|
||||
(within the usual 5 min save interval otherwise).
|
||||
- **Failure when nothing was seen.** With no level we cannot call a pack full.
|
||||
The failure costs a 7-day wait and one notice; calling it done costs a
|
||||
missed balance and a month-long false "complete". The first is the honest one.
|
||||
- **Timeouts count the same minutes as with a reading.** Gate-open charging
|
||||
minutes only; the wall backstop for a gate that never opens.
|
||||
- **15 min.** A judgement. A poll glitch of a few minutes should not write a
|
||||
line; a reading lost for a quarter of an hour is worth one. Raise it if the
|
||||
action log shows noise.
|
||||
- **0 W, not "stop the phase".** Aborting a drain on a short gap would throw
|
||||
away the part already drained. Holding at 0 W loses nothing and the 12 h
|
||||
timeout is the limit.
|
||||
|
||||
## Cost
|
||||
|
||||
- A drain that loses its reading stops draining, and the 12 h clock keeps
|
||||
running. A gap of many hours can therefore fail a drain that was working. The
|
||||
back-off then applies (7 days).
|
||||
- A charge whose reading is lost early (last SoC below target - 3) fails at the
|
||||
timeout, even if the pack was in fact filling. The same 7-day wait applies.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- **HOLD with no SoC** still holds 0 W and, as before, does not end while the
|
||||
reading is missing: its time check sits behind the same early return. A HOLD
|
||||
needs no level to end, so this is a candidate follow-up, not part of this fix. It is card MAINT-15. The "no battery level" line in
|
||||
HOLD says only that the hold waits for the level.
|
||||
- It does not tell the operator why the reading is missing (sensor, register,
|
||||
link). It does not reuse the stale-input gate; it is the cycle's own rule.
|
||||
- The charge itself is still driven by the control loop, which has its own
|
||||
handling of a missing SoC (TEL-08 for the loop is a separate card).
|
||||
- A restart loses at most 5 min of accounting, as in MAINT-13. The "unknown for
|
||||
long" line may be said again after a restart: the episode start is in memory.
|
||||
- Text added is two log lines, English only, like the other log lines.
|
||||
@@ -0,0 +1,80 @@
|
||||
# SAFETY-103 - no swing on old battery readings after a drain ends
|
||||
|
||||
**Status: implemented 2026-10-08, for review.** Tests: `test_safety103.py`.
|
||||
|
||||
**The defect** (SAFETY-95 rig test, check 5, F1). While a battery settles
|
||||
from its ended drain, SAFETY-95 steers on the house's point: grid + every
|
||||
battery's reading - aim. The meter is 1 s old; a battery register can be
|
||||
10 s old (the SAFETY-90 register model). At E+13 A's reading said 1238 W
|
||||
(6.8 s old) while A was at 616 W, so the house looked ~620 W bigger: B went
|
||||
860 -> 1650 -> 870 W. B's own old reading does the same the other way.
|
||||
|
||||
**The rule** (`main.py`, `_track_reads()`, `_drain_grid_w()`, N>=2, only
|
||||
while a drain's tail settles):
|
||||
|
||||
1. Each cycle, per battery: the range its power can be in. That is its last
|
||||
changed reading, widened by every command on its wire since (a lagging
|
||||
battery moves from one toward the others, never beyond). A new reading
|
||||
starts the range again.
|
||||
2. A reading that changed this cycle is taken as it reads. So is the side a
|
||||
battery refuses (SAFETY-73): it is not heading that way.
|
||||
3. The house point is held (first cycle: the loop's start from SAFETY-95).
|
||||
It moves only as far as the meter proves: to the nearest value of grid +
|
||||
the batteries' ranges - aim.
|
||||
|
||||
So the loop no longer moves on a reading that has not caught up. A real
|
||||
house step still moves it, as soon as the meter shows more than the
|
||||
batteries can explain.
|
||||
|
||||
**Why not the tester's rule** ("a battery whose reading is older than its
|
||||
last command counts at its command"). B's command changes almost every
|
||||
cycle, so B is almost always at its command. That is the plain meter, which
|
||||
chases A's tail: B swings 1420 W. A lag model needs the plant's time
|
||||
constant, which is not known for a client's inverter. Measured on the plant
|
||||
below (N=2, 1200 W, A Off; swing = a move of the others later undone):
|
||||
|
||||
| rule | 10 s lag | 5 s lag | 20 s lag | surplus, 5 s lag |
|
||||
|---|---|---|---|---|
|
||||
| release/1.0 (readings) | 760 | 840 | 150 | 800 |
|
||||
| tester's: at the command | 1420 | 1020 | 1600 | 800 |
|
||||
| lag model, tau 10 s | 70 | 140 | 80 | 580 |
|
||||
| lag model, tau 5 s, plant 20 s | | | 600 | |
|
||||
| hold all window | 0 | 0 | 0 | 0 |
|
||||
| **this rule** | **0** | **0** | **0** | **130** |
|
||||
|
||||
Holding all window ignores a house step: a 2 kW kettle at E+5 s imported
|
||||
14.4 Wh over the next 30 s (release 11.5, this rule 11.3); 2 kW more sun
|
||||
exported 16.9 Wh (release 8.5, this rule 8.9).
|
||||
|
||||
**Before -> after** (`test_safety103.py`, `tools/safety103_plant.py`: 800
|
||||
W/s ramp, 10 s lag, meter 1 s, registers 10 s at the rig's phases, B idles
|
||||
at -100 W; summed swing of the others in the 23 s after the end):
|
||||
|
||||
| case | release/1.0 | after |
|
||||
|---|---|---|
|
||||
| rig check 5: N=2, 1200 W, A Off | B 1140 -> 850 -> 1630 -> 870, swing 760 W | B holds 1140 W |
|
||||
| N=3, 1200 W / 4000 W, A Off | 680 / 630 W | 0 / 0 W |
|
||||
| solar surplus, N=2 / N=3 | 890 / 740 W | 130 / 130 W |
|
||||
| lag 5 or 20 s, registers 5 or 10 s, N=2 and N=3 | | at most 10 W |
|
||||
| registers as fresh as the meter (1 s) | | rows byte-identical |
|
||||
| refusal end | | rows byte-identical |
|
||||
| N=1, every end | | rows byte-identical (also against the release/1.0 tree) |
|
||||
|
||||
**Cost.** In the window, a house change smaller than what the batteries
|
||||
could still be doing is not followed until a reading catches up (at most a
|
||||
register period) or the window ends (23 s). Under a surplus the others
|
||||
still swing up to 130 W, a third of a slew step.
|
||||
|
||||
**Not covered.**
|
||||
- Outside the drain tail the loop steers on the meter; readings only reach
|
||||
the saturation freeze (SAFETY-96), unchanged.
|
||||
- A lost link or a refusal ends the tail at once (A is out of the split, or
|
||||
reads ~0 W). The swing after them is the loop's own on a lagging plant,
|
||||
the same with 1 s registers and on release/1.0: under a surplus up to
|
||||
1.5 kW at N=2 and 3.9 kW summed at N=3; after a lost link about 1 kW
|
||||
even without one. Not this card.
|
||||
- A battery that overshoots its command, or a reading offset beyond the
|
||||
range, can put the true power outside the range; the meter then moves the
|
||||
point, as before.
|
||||
- The end cycle's start (SAFETY-95 step 2) still uses the readings; the
|
||||
batteries were steady during the drain, so they are current there.
|
||||
@@ -1667,6 +1667,21 @@ hour saved. If you set an earlier hour to get an evening start in UTC (for
|
||||
example 17 for 19:00 in summer), set it to 19. The add-on never changes a saved
|
||||
value. *For installers:* DECISIONS/MAINT-10-local-start-hour.md.
|
||||
|
||||
**When the charge counts as done.** A battery may stop at 98 or 99 % while it
|
||||
balances, so it need not reach `maintenance_soc_target`. The charge counts as
|
||||
done when the battery is within 3 points of the target and has taken no more
|
||||
charge for 60 minutes of charging time, or when the charging time (36 hours) runs
|
||||
out within 3 points of the target. Only the minutes the cheap-hours gate let the
|
||||
battery charge count, and the charge ends after 7 days at the
|
||||
latest. Then the usual hold follows.
|
||||
|
||||
**When a cycle fails.** If the battery does not empty in 12 hours, or does not
|
||||
get within 3 points of the target in 36 hours of charging time, the cycle
|
||||
stops, you get the notification *Battery cycle did not finish*, and it is not
|
||||
tried again for 7 days. The status page shows *Maintenance paused* with the
|
||||
date. Starting a cycle by hand ignores the wait. *For installers:*
|
||||
DECISIONS/MAINT-13-full-pack-is-complete.md.
|
||||
|
||||
### Tariff (all optional)
|
||||
|
||||
| option | meaning |
|
||||
@@ -1704,7 +1719,8 @@ When a battery's link drops, the others take over one slew step a cycle,
|
||||
and control does not stall on the dropped battery's power (SAFETY-96).
|
||||
When a drain ends (done, Off, timeout, abort, lost link, refused), the
|
||||
other batteries cover the house at once but do not export its drain; then
|
||||
they move one slew step a cycle (SAFETY-95).
|
||||
they move one slew step a cycle (SAFETY-95). While that battery settles,
|
||||
an old battery reading does not move them (SAFETY-103).
|
||||
|
||||
#### Capacity-tariff exposure of the grid-following loop
|
||||
|
||||
@@ -3249,6 +3265,14 @@ reading is stuck. Control keeps running and keeps following the reading, so a
|
||||
stuck reading can raise this month's peak. Check the meter. If it is stuck,
|
||||
stop control on the add-on page.
|
||||
|
||||
### Battery cycle did not finish
|
||||
|
||||
The monthly battery cycle stopped because the battery did not empty, or did not
|
||||
fill up, in time. The battery is back under normal control. The add-on waits 7
|
||||
days before it tries again, so it does not empty the battery every night. To
|
||||
try sooner, start a cycle on the add-on page. If it keeps happening, check that
|
||||
the battery follows its commands and that the cheap hours leave time to charge.
|
||||
|
||||
### For installers: notifications
|
||||
|
||||
This part is for installers. The texts live in `app/messages.py` and follow
|
||||
@@ -3268,6 +3292,7 @@ default `info` hides it.
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` | SAFETY-31 |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` | SAFETY-42 |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` | SAFETY-18 |
|
||||
| Battery cycle did not finish | warning | `goodwe_maint_failed_<name>` | MAINT-13 |
|
||||
|
||||
**The Details link.** Home Assistant 2026.2 and newer show add-on pages at
|
||||
`/config/app/<slug>/documentation`; 2026.5 removed the old
|
||||
|
||||
+111
-10
@@ -77,7 +77,7 @@ from .inverter import (LINK_STALE_S, UNIT_A, build_roster,
|
||||
roster_entries, roster_names)
|
||||
from .maintenance import (
|
||||
CHARGE, DRAIN, HOLD, IDLE, POWER_MOVING, MaintConfig, Maintenance,
|
||||
MaintResult, arbitrate as maint_arbitrate, site_zone,
|
||||
FAIL_BACKOFF_DAYS, MaintResult, arbitrate as maint_arbitrate, site_zone,
|
||||
)
|
||||
from .mqtt import (MODE_CONFIGS_KEY, MODE_LABELS, USE_OFF, USE_ON,
|
||||
MqttPublisher, announced_units, mode_configs,
|
||||
@@ -91,7 +91,7 @@ from .price import Absence, Uncertainty, brussels, price_option, provider_config
|
||||
from .price import required_spread as price_required_spread
|
||||
from .price import uncertainty_of as price_uncertainty_of
|
||||
from .price_history import PriceHistory
|
||||
from .static_tariff import resolve_tariff, static_status
|
||||
from .static_tariff import resolve_tariff, static_gated, static_status
|
||||
from .tariff import PeakStore, PeakTracker, next_quarter
|
||||
from .store import migrate_maint_keys, migrate_unit_keys
|
||||
from .validate import (FIRMWARE_INGEST_VETO_S, ConfigRefused, refuse,
|
||||
@@ -1031,6 +1031,11 @@ class Controller:
|
||||
# SAFETY-95: batteries settling after their drain ended; meanwhile
|
||||
# the loop's error counts every battery at its command.
|
||||
self._drain_tail = set()
|
||||
# SAFETY-103: per battery, the range its power can be in since its
|
||||
# reading last changed (that reading and every command since), and
|
||||
# the house point held while a drain's tail settles.
|
||||
self._read_span = {}
|
||||
self._drain_house = None
|
||||
# SAFETY-96: last cycle's commandable batteries, this cycle's start
|
||||
# point per battery where a reseed moved it, and batteries settling
|
||||
# after a step the loop did not make ({name: since, monotonic}).
|
||||
@@ -1183,6 +1188,8 @@ class Controller:
|
||||
self.grid = None
|
||||
self.peak_fc = None
|
||||
self.cheap = False
|
||||
self._price_gated = False # MAINT-13: is a price gate set up
|
||||
self._gated_key = None # MAINT-13: (options, hour) of the cache
|
||||
# TARIFF-03. One line of prose for the status page saying WHICH tariff
|
||||
# window we are in and why it is or is not cheap - so "Cheap window:
|
||||
# no" is an evidenced answer rather than a bare no.
|
||||
@@ -2527,13 +2534,56 @@ class Controller:
|
||||
most PLANT_SETTLE_DOWN_S), the meter still shows the drain's tail and
|
||||
the others' climb, so the loop would chase them (B down, then up
|
||||
again). Meanwhile the batteries count at the site command: the error
|
||||
is the house's own point minus the loop's start."""
|
||||
is the house's own point minus the loop's start.
|
||||
|
||||
SAFETY-103: a reading can be up to a register period (10 s) older
|
||||
than the meter, so the house point is held, and moved only as far as
|
||||
the meter proves: to the nearest value the batteries can be at (each
|
||||
between its last changed reading and its commands since; a reading
|
||||
that changed this cycle, or the side a battery refuses, is taken as
|
||||
it reads). DECISIONS/SAFETY-103-old-readings-after-a-drain.md.
|
||||
"""
|
||||
grid = float(self.grid)
|
||||
self._drain_tail &= set(self._settle) & set(live)
|
||||
if not self._drain_tail:
|
||||
self._drain_house = None
|
||||
return grid
|
||||
return grid - float(self.target) + sum(
|
||||
float(inv.batt) for inv in self.inverters if inv.name in live)
|
||||
aim = self.tuning.target_grid_w
|
||||
lo = hi = grid - aim
|
||||
for inv in self.inverters:
|
||||
if inv.name not in live:
|
||||
continue
|
||||
r = float(inv.batt)
|
||||
span = self._read_span.get(inv.name)
|
||||
if (span is None or span[2] != inv.batt_fresh.changed_mono
|
||||
or span[2] == self._now_mono):
|
||||
span = (r, r)
|
||||
# A battery that refuses one way (SAFETY-73) is not heading
|
||||
# that way, whatever it was asked: that side is its reading.
|
||||
if (inv.refused or 0) > 0:
|
||||
span = (min(span[0], r), r)
|
||||
elif (inv.refused or 0) < 0:
|
||||
span = (r, max(span[1], r))
|
||||
lo, hi = lo + span[0], hi + span[1]
|
||||
held = (float(self.target) if self._drain_house is None
|
||||
else self._drain_house)
|
||||
self._drain_house = min(hi, max(lo, held))
|
||||
return self._drain_house - float(self.target) + aim
|
||||
|
||||
def _track_reads(self) -> None:
|
||||
"""SAFETY-103, N>=2: per battery, the range its power can be in now:
|
||||
its last changed reading and every command on its wire since (a
|
||||
lagging battery moves from one toward the others, never beyond)."""
|
||||
if len(self.inverters) < 2:
|
||||
return
|
||||
for inv in self.inverters:
|
||||
if inv.batt is None:
|
||||
continue
|
||||
cmd, since = inv.standing_w(), inv.batt_fresh.changed_mono
|
||||
lo, hi, was = self._read_span.get(inv.name, (0.0, 0.0, None))
|
||||
if was is None or since != was:
|
||||
lo = hi = float(inv.batt)
|
||||
self._read_span[inv.name] = (min(lo, cmd), max(hi, cmd), since)
|
||||
|
||||
def _reseed_drop(self, live) -> None:
|
||||
"""SAFETY-96, N>=2: a battery that drops out of the split (stale
|
||||
@@ -3264,6 +3314,7 @@ class Controller:
|
||||
now_p = await self.hass.number(now_e)
|
||||
avg_p = await self.hass.number(avg_e)
|
||||
self.cheap = (now_p is not None and avg_p is not None and now_p <= avg_p)
|
||||
self._price_gated = True
|
||||
self.tariff_words = "Prices from Home Assistant entities"
|
||||
else:
|
||||
# TARIFF-03. §9.2 makes a static day/night tariff a first-class
|
||||
@@ -3287,8 +3338,9 @@ class Controller:
|
||||
# ⚠️ AND IT CANNOT BE BOTH. validate.py refuses static_profile
|
||||
# alongside the two Home Assistant entities, because this `if` picks
|
||||
# one and the loser is silent.
|
||||
self.cheap, self.tariff_words = static_status(
|
||||
o, datetime.now(timezone.utc))
|
||||
_now = datetime.now(timezone.utc)
|
||||
self.cheap, self.tariff_words = static_status(o, _now)
|
||||
self._price_gated = self._static_gated(o, _now)
|
||||
|
||||
# ⚠️ TARIFF-11. THE PROVIDER PLAN REACHES THE *Tariff* ROW HERE, AND
|
||||
# THIS IS THE ONLY PLACE THE TWO SOURCES MEET. Everything above is the
|
||||
@@ -3827,6 +3879,29 @@ class Controller:
|
||||
inv.refusal_note())]
|
||||
if n]
|
||||
|
||||
def _static_gated(self, o: dict, now: datetime) -> bool:
|
||||
"""`static_gated()`, worked out once an hour: it builds the same
|
||||
month-long plan as `static_status()` (about 20 ms with a profile), and
|
||||
whether a fixed tariff is set up does not change from tick to tick
|
||||
(options change only with a restart)."""
|
||||
key = (id(o), now.strftime("%Y-%m-%d %H"))
|
||||
if key != self._gated_key:
|
||||
self._gated_key, self._gated = key, static_gated(o, now)
|
||||
return self._gated
|
||||
|
||||
def _charge_gate_open(self, inv) -> bool:
|
||||
"""MAINT-13: may this pack charge now, for the maintenance timeout?
|
||||
|
||||
True when no price gate is set up (no price entities, no fixed tariff:
|
||||
nothing holds the charge back), in a cheap window, or while the pack is
|
||||
really taking charge (sun outside cheap hours). Closed only when a gate
|
||||
exists, it is shut, and the pack is not charging.
|
||||
"""
|
||||
if not self._price_gated or self.cheap:
|
||||
return True
|
||||
batt = inv.batt
|
||||
return batt is not None and float(batt) <= -MAINT_CHARGING_W
|
||||
|
||||
async def cycle(self) -> None:
|
||||
"""Gather claims, resolve precedence, write the winner.
|
||||
|
||||
@@ -3875,10 +3950,24 @@ class Controller:
|
||||
if blocked is None:
|
||||
maint_results.append(MaintResult(IDLE, False, None, False, []))
|
||||
continue
|
||||
res = machine.tick(now, inv.soc, blocked_by=blocked)
|
||||
# MAINT-13: the charge timeout counts only the minutes the pack was
|
||||
# allowed to charge (see `_charge_gate_open`).
|
||||
res = machine.tick(now, inv.soc, blocked_by=blocked,
|
||||
gate_open=self._charge_gate_open(inv))
|
||||
for msg in res.events:
|
||||
self.log_event(msg, hint=messages.hint("maintenance",
|
||||
phase=machine.phase))
|
||||
self.log_event(msg, hint=messages.hint(
|
||||
"maint_failed" if res.failed else "maintenance",
|
||||
phase=machine.phase))
|
||||
if res.failed:
|
||||
# Said once: only the tick that failed carries `res.failed`.
|
||||
multi = len(self.inverters) > 1
|
||||
slug = (unit_slugs(self.units)[self.inverters.index(inv)]
|
||||
if multi else "battery")
|
||||
await self.hass.call(
|
||||
"persistent_notification", "create",
|
||||
messages.maint_failed(
|
||||
res.failed, FAIL_BACKOFF_DAYS,
|
||||
unit=inv.name if multi else "", slug=slug).data())
|
||||
maint_results.append(res)
|
||||
# ⚠️ CARRIED TO THE STATUS PAGE, NOT LEFT IN THE 40-LINE ACTION LOG. The
|
||||
# deferral is edge-logged (it lasts as long as the other pack's cycle),
|
||||
@@ -4914,6 +5003,9 @@ class Controller:
|
||||
# level: the two halves of §6.2's identity break in opposite
|
||||
# directions. See `site_batt_w` and test_alloc.py part 8.
|
||||
site_batt = self.site_batt_w
|
||||
# SAFETY-103: what each battery can be doing (its reading may be
|
||||
# older than the meter).
|
||||
self._track_reads()
|
||||
# SAFETY-96: a battery the loop cannot move counts at its command,
|
||||
# so its own power does not freeze the loop (the meter has it).
|
||||
site_batt += self._held_out_w(_live96)
|
||||
@@ -7049,6 +7141,7 @@ class Controller:
|
||||
# date, unchanged.
|
||||
_now = datetime.now(timezone.utc)
|
||||
_dues = [m.next_due(_now) for m in self.maints]
|
||||
_waits = [u for u in (m.backoff_until(_now) for m in self.maints) if u]
|
||||
next_due = None if any(d is None for d in _dues) else min(_dues)
|
||||
rows = [
|
||||
("Grid", w(self.grid)),
|
||||
@@ -7096,6 +7189,10 @@ class Controller:
|
||||
*((("Maintenance waiting", "; ".join(f"{n}: {why}"
|
||||
for n, why in self._maint_deferred)),)
|
||||
if self._maint_deferred else ()),
|
||||
# MAINT-13: only while a failed cycle waits, so a site with nothing
|
||||
# failed carries exactly the rows it carried before.
|
||||
*((("Maintenance paused", messages.row_maint_waits(
|
||||
min(_waits).strftime("%Y-%m-%d"))),) if _waits else ()),
|
||||
("Maintenance due", "now" if next_due is None else next_due.strftime("%Y-%m-%d")),
|
||||
("Cheap window", "yes" if self.cheap else "no"),
|
||||
("Tariff", self.tariff_words),
|
||||
@@ -7317,6 +7414,10 @@ class Controller:
|
||||
return None
|
||||
|
||||
|
||||
# MAINT-13: a battery power reading at or below minus this many W is a pack
|
||||
# that is taking charge.
|
||||
MAINT_CHARGING_W = 50.0
|
||||
|
||||
# SAFETY-61. Exit status when the control task dies; 70 is sysexits(3)
|
||||
# EX_SOFTWARE. See DECISIONS/SAFETY-61-control-task-death.md.
|
||||
EXIT_CONTROL_DIED = 70
|
||||
|
||||
@@ -65,10 +65,30 @@ POWER_MOVING = (DRAIN, CHARGE, HOLD)
|
||||
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# it is expected to span a night; 36 h still bounds it.
|
||||
DRAIN_TIMEOUT_MIN = 720
|
||||
# MAINT-13: minutes the pack was ALLOWED to charge (the price gate open), not
|
||||
# wall-clock minutes since the charge began. See CHARGE_WALL_TIMEOUT_MIN.
|
||||
CHARGE_TIMEOUT_MIN = 2160
|
||||
# After an abort, do not immediately re-trigger in the same start hour.
|
||||
RESTART_COOLDOWN_MIN = 90
|
||||
|
||||
# MAINT-13 (DECISIONS/MAINT-13-full-pack-is-complete.md). Constants, not options.
|
||||
# A pack that reaches target - 3 and then takes no more charge for this many
|
||||
# minutes of allowed charging counts as full.
|
||||
CHARGE_NEAR_FULL_PCT = 3
|
||||
CHARGE_STALL_MIN = 60
|
||||
# Wall-clock backstop for a charge whose gate never opens (no cheap hours, no sun).
|
||||
CHARGE_WALL_TIMEOUT_MIN = 10080
|
||||
# A failed cycle (stuck drain or charge) is not retried before this many days.
|
||||
FAIL_BACKOFF_DAYS = 7
|
||||
# One tick counts at most this many minutes: a gap means the add-on was down.
|
||||
CHARGE_TICK_MAX_MIN = 5
|
||||
# The charge accounting is written to the state file at most this often.
|
||||
CHARGE_SAVE_MIN = 5
|
||||
# MAINT-14 (DECISIONS/MAINT-14-no-soc-in-maintenance.md): with no SoC reading
|
||||
# the timeouts still run, a drain holds at 0 W, and the log says once, after this
|
||||
# many minutes, that the level has been unknown for long.
|
||||
NOSOC_NOTE_MIN = 15
|
||||
|
||||
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
|
||||
# OPTION, and the only place in the add-on where one of these numbers is typed.
|
||||
#
|
||||
@@ -257,6 +277,9 @@ class MaintResult:
|
||||
# showing an idle machine and a due date in the past. Empty on every path
|
||||
# that is not deferring, so a roster of one never sees it.
|
||||
deferred: str = ""
|
||||
# MAINT-13: "drain" or "charge" on the one tick where a cycle FAILED, so
|
||||
# the Controller can tell the operator once. Empty on every other tick.
|
||||
failed: str = ""
|
||||
|
||||
|
||||
class UnitHistory:
|
||||
@@ -344,6 +367,14 @@ class Maintenance:
|
||||
# per cycle would flush the very context that explains it. Same pattern
|
||||
# as `Controller._arb_action` and `_maint_shape_suspended`.
|
||||
self._deferred = ""
|
||||
# MAINT-13: the charge accounting (see _charge_account), in memory and
|
||||
# written to the state file every CHARGE_SAVE_MIN minutes.
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
# MAINT-14: when the SoC reading went missing (None while it is there),
|
||||
# and whether the "unknown for long" line was said in this episode.
|
||||
self._nosoc_since = None
|
||||
self._nosoc_said = False
|
||||
|
||||
# -- state ---------------------------------------------------------------
|
||||
@property
|
||||
@@ -351,6 +382,11 @@ class Maintenance:
|
||||
return self.store.get("phase", IDLE)
|
||||
|
||||
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
|
||||
self._nosoc_since = None
|
||||
self._trk = None
|
||||
self._trk_saved = None
|
||||
if self.store.get("charge_track") is not None:
|
||||
self.store.set("charge_track", None)
|
||||
self.store.set("phase", phase)
|
||||
self.store.set_time("phase_started", now)
|
||||
_LOG.info("%s", msg)
|
||||
@@ -391,6 +427,21 @@ class Maintenance:
|
||||
return (last_try is None
|
||||
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN))
|
||||
|
||||
def backoff_until(self, now: datetime):
|
||||
"""MAINT-13: when a failed cycle may be tried again, or None.
|
||||
|
||||
None when nothing failed, when the back-off is over, or when a cycle
|
||||
completed after the failure (a forced start that worked ends it).
|
||||
"""
|
||||
failed = self.store.get_time("last_failed")
|
||||
if failed is None:
|
||||
return None
|
||||
done = self.store.get_time("last_completed")
|
||||
if done is not None and done >= failed:
|
||||
return None
|
||||
until = failed + timedelta(days=FAIL_BACKOFF_DAYS)
|
||||
return until if now < until else None
|
||||
|
||||
def wants_start(self, now: datetime) -> bool:
|
||||
"""Would this pack begin a cycle on this tick if the site let it?
|
||||
|
||||
@@ -402,7 +453,8 @@ class Maintenance:
|
||||
return (self.phase == IDLE and self.cfg.enabled
|
||||
and in_start_slot(now, self.cfg.start_hour, self.tz)
|
||||
and self.due(now)
|
||||
and self._cooled(now))
|
||||
and self._cooled(now)
|
||||
and self.backoff_until(now) is None)
|
||||
|
||||
# -- operations ----------------------------------------------------------
|
||||
def force_start(self, now: datetime, blocked_by: str = "") -> list:
|
||||
@@ -430,6 +482,122 @@ class Maintenance:
|
||||
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
|
||||
return events
|
||||
|
||||
def _charge_account(self, now: datetime, soc: float | None,
|
||||
gate_open: bool) -> dict:
|
||||
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
|
||||
|
||||
`open_min` counts only ticks with the price gate open; `flat_min` counts
|
||||
gate-open minutes since the SoC last beat its best; a closed gate pauses
|
||||
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
|
||||
counts for nothing. A state file from before MAINT-13, or from another
|
||||
charge, starts from the wall-clock minutes so far: the old behaviour.
|
||||
|
||||
MAINT-14: `soc` may be None (no reading). Time still counts, the stall
|
||||
wait pauses, and `last` keeps the last SoC seen (saved with the rest).
|
||||
"""
|
||||
since = self.store.get("phase_started")
|
||||
trk = self._trk
|
||||
if trk is None:
|
||||
raw = self.store.get("charge_track")
|
||||
if isinstance(raw, dict) and raw.get("since") == since:
|
||||
trk = dict(raw)
|
||||
else:
|
||||
trk = {"since": since, "open_min": self._elapsed_min(now),
|
||||
"flat_min": 0.0,
|
||||
"best": None if soc is None else float(soc),
|
||||
"last": None if soc is None else float(soc), "at": None}
|
||||
self._trk = trk
|
||||
at = trk.get("at")
|
||||
try:
|
||||
last = datetime.fromisoformat(at) if at else None
|
||||
except (TypeError, ValueError):
|
||||
last = None
|
||||
dt = 0.0 if last is None else min(
|
||||
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
|
||||
trk["at"] = now.isoformat()
|
||||
if soc is None:
|
||||
pass
|
||||
elif trk.get("best") is None or soc > trk["best"]:
|
||||
trk["best"], trk["flat_min"] = float(soc), 0.0
|
||||
elif gate_open:
|
||||
trk["flat_min"] += dt
|
||||
if soc is not None:
|
||||
trk["last"] = float(soc)
|
||||
if gate_open:
|
||||
trk["open_min"] += dt
|
||||
saved = self._trk_saved
|
||||
if saved is None or (now - saved).total_seconds() >= CHARGE_SAVE_MIN * 60:
|
||||
self.store.set("charge_track", dict(trk))
|
||||
self._trk_saved = now
|
||||
return trk
|
||||
|
||||
def _fail(self, now: datetime, kind: str, why: str) -> MaintResult:
|
||||
"""MAINT-13: stand down, remember the failure, and tell the Controller."""
|
||||
events = self.abort(now, why)
|
||||
self.store.set_time("last_failed", now)
|
||||
msg = (f"maintenance: the cycle did not finish. It waits "
|
||||
f"{FAIL_BACKOFF_DAYS} days before it tries again.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
Nothing here may start a phase change that needs the level.
|
||||
"""
|
||||
if self._nosoc_since is None:
|
||||
self._nosoc_since = now
|
||||
self._nosoc_said = False
|
||||
self._trk_saved = None # save the last SoC seen, now
|
||||
if phase == DRAIN:
|
||||
msg = ("maintenance: the battery level is unknown, so the "
|
||||
"drain holds at 0 W until it is back.")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
tail = ("The hold waits for the level to come back."
|
||||
if phase == HOLD else
|
||||
f"The time limit of the {phase} still applies.")
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
f"{tail}")
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
return self._fail(now, "drain",
|
||||
f"drain stuck, battery level unknown, after "
|
||||
f"{elapsed / 60:.0f} h")
|
||||
return MaintResult(DRAIN, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, None, gate_open)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
last = trk.get("last")
|
||||
if last is not None and last >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up and the last level "
|
||||
f"seen was {last:.0f} %, close enough to full, so the "
|
||||
f"charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if elapsed > CHARGE_WALL_TIMEOUT_MIN:
|
||||
lim = f"the {CHARGE_WALL_TIMEOUT_MIN // 1440}-day limit"
|
||||
else:
|
||||
lim = f"{trk['open_min'] / 60:.0f} h of charging time"
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck, battery level unknown, after {lim}")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
def abort(self, now: datetime, why: str) -> list:
|
||||
events = []
|
||||
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
|
||||
@@ -457,13 +625,16 @@ class Maintenance:
|
||||
|
||||
# -- the machine ---------------------------------------------------------
|
||||
def tick(self, now: datetime, soc: float | None,
|
||||
blocked_by: str = "") -> MaintResult:
|
||||
blocked_by: str = "", gate_open: bool = True) -> MaintResult:
|
||||
"""One cycle of this pack's state machine.
|
||||
|
||||
`blocked_by` is `arbitrate()`'s answer for THIS pack: empty when the
|
||||
site's one maintenance slot is available to it, otherwise the reason it
|
||||
is not. It gates two things and nothing else - a start, and a phase that
|
||||
is already moving power on a pack that does not hold the slot.
|
||||
|
||||
`gate_open` (MAINT-13) is whether the pack may charge now (the price
|
||||
gate); only those minutes count towards the charge timeout.
|
||||
"""
|
||||
events: list = []
|
||||
phase = self.phase
|
||||
@@ -514,13 +685,13 @@ class Maintenance:
|
||||
# transitions below mean anything, and a stale "100 %" would end the
|
||||
# charge phase having charged nothing. Hold the current phase's command
|
||||
# and wait; the phase timeout is the backstop.
|
||||
#
|
||||
# MAINT-14: "hold and wait" is not "wait for ever". The timeouts run
|
||||
# here too, and a drain holds at 0 W (an unknown level never allows
|
||||
# discharge, TEL-08). See `_no_soc`.
|
||||
if soc is None:
|
||||
_LOG.warning("maintenance: no SoC reading, holding phase %s", phase)
|
||||
if phase == DRAIN:
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
return self._no_soc(now, phase, gate_open, events)
|
||||
self._nosoc_since = None
|
||||
|
||||
elapsed = self._elapsed_min(now)
|
||||
|
||||
@@ -531,8 +702,8 @@ class Maintenance:
|
||||
f"after {elapsed:.0f} min -> charge")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
events += self.abort(now, f"drain stuck at {soc:.0f} % after {elapsed:.0f} min")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
return self._fail(now, "drain", f"drain stuck at {soc:.0f} % "
|
||||
f"after {elapsed:.0f} min")
|
||||
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
|
||||
|
||||
if phase == CHARGE:
|
||||
@@ -541,9 +712,27 @@ class Maintenance:
|
||||
f"maintenance: charge complete at {soc:.0f} % after "
|
||||
f"{elapsed:.0f} min -> holding {self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if elapsed > CHARGE_TIMEOUT_MIN:
|
||||
events += self.abort(now, f"charge stuck at {soc:.0f} % after {elapsed:.0f} min")
|
||||
return MaintResult(IDLE, True, 0.0, False, events)
|
||||
trk = self._charge_account(now, soc, gate_open)
|
||||
near = soc >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT
|
||||
# MAINT-13 rule 1: close to full and no longer taking charge.
|
||||
if near and trk["flat_min"] >= CHARGE_STALL_MIN:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: the battery takes no more charge at "
|
||||
f"{soc:.0f} %, so the charge counts as done -> holding "
|
||||
f"{self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
|
||||
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
|
||||
# MAINT-13 rule 2: out of time close to full is complete.
|
||||
if near:
|
||||
self._enter(HOLD, now, events,
|
||||
f"maintenance: charge time is up at {soc:.0f} %, "
|
||||
f"close enough to full, so the charge counts as "
|
||||
f"done -> holding {self.cfg.hold_min} min to balance")
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._fail(now, "charge",
|
||||
f"charge stuck at {soc:.0f} % after "
|
||||
f"{trk['open_min']:.0f} min of charging time")
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
if phase == HOLD:
|
||||
|
||||
@@ -102,6 +102,7 @@ class Notice:
|
||||
title: str
|
||||
body: str
|
||||
section: str = "" # the DOCS.md heading, when it is not the title itself
|
||||
body_nl: str = "" # MAINT-13: the same words in Dutch, shown under the English
|
||||
|
||||
@property
|
||||
def docs(self) -> str:
|
||||
@@ -110,7 +111,9 @@ class Notice:
|
||||
def data(self) -> dict:
|
||||
"""The `persistent_notification.create` payload."""
|
||||
return {"notification_id": self.id, "title": self.title,
|
||||
"message": f"{self.body}\n\n{details(self.docs)}"}
|
||||
"message": f"{self.body}\n\n"
|
||||
+ (f"{self.body_nl}\n\n" if self.body_nl else "")
|
||||
+ details(self.docs)}
|
||||
|
||||
|
||||
# --- the catalogue ----------------------------------------------------------
|
||||
@@ -124,6 +127,8 @@ T_CIRCULATING = "Inverters working against each other"
|
||||
T_NOT_DELIVERING = "{unit} is not delivering"
|
||||
S_NOT_DELIVERING = "An inverter is not delivering"
|
||||
T_METER_FROZEN = "Meter reading may be stuck"
|
||||
T_MAINT_FAILED = "Battery cycle did not finish"
|
||||
T_MAINT_FAILED_NL = "Batterijcyclus niet afgerond"
|
||||
|
||||
ID_LOOP_BOUND = "goodwe_integrator_bound"
|
||||
ID_OUTPUT_CLAMP = "goodwe_output_clamp"
|
||||
@@ -132,6 +137,7 @@ ID_PEAK_RESERVE = "goodwe_peak_soc_floor"
|
||||
ID_CIRCULATING = "goodwe_circulating_power"
|
||||
ID_NOT_DELIVERING = "goodwe_not_delivering_{slug}"
|
||||
ID_METER_FROZEN = "goodwe_meter_frozen"
|
||||
ID_MAINT_FAILED = "goodwe_maint_failed_{slug}"
|
||||
|
||||
# Which limit cut a command (clamp.ClampResult.bound, plus the loop's own).
|
||||
# The setting is named by its label, "Inverter rating (W)".
|
||||
@@ -295,6 +301,24 @@ def meter_frozen(unchanged_s) -> Notice:
|
||||
f"stop control on the add-on page.")
|
||||
|
||||
|
||||
def maint_failed(kind: str, days: int, unit: str = "", slug: str = "") -> Notice:
|
||||
"""MAINT-13: a monthly cycle stopped before it was done. Said once."""
|
||||
full = kind == "charge"
|
||||
who = unit or "The battery"
|
||||
who_nl = unit or "De batterij"
|
||||
en = f"{who} did not {'fill up' if full else 'empty'}, so its cycle " \
|
||||
f"stopped and tries again in {days} days."
|
||||
nl = f"{who_nl} raakte niet {'vol' if full else 'leeg'}, dus de cyclus is " \
|
||||
f"gestopt en probeert het over {days} dagen opnieuw."
|
||||
return Notice(ID_MAINT_FAILED.format(slug=slug or "battery"), WARNING,
|
||||
T_MAINT_FAILED, en, body_nl=f"{T_MAINT_FAILED_NL}. {nl}")
|
||||
|
||||
|
||||
def row_maint_waits(until_text: str) -> str:
|
||||
"""MAINT-13: the status row while a failed cycle waits."""
|
||||
return f"Waits until {until_text} after a cycle that did not finish."
|
||||
|
||||
|
||||
# --- the status page (UX-08 phase 2b) ----------------------------------------
|
||||
# The rows of the Commissioning list and the banner at the top of the add-on
|
||||
# page. `main.py` decides WHEN a row shows and its colour (ok / warn / bad);
|
||||
@@ -947,6 +971,7 @@ HINTS = {
|
||||
"not_delivering_cleared": "{unit}: not-delivering alarm cleared",
|
||||
"maintenance": "Battery maintenance: {phase}",
|
||||
"maint_paused": "Maintenance charging paused to stay under the peak limit",
|
||||
"maint_failed": "The battery cycle did not finish, so it waits before trying again",
|
||||
"pack_on": "{unit}: battery switched on",
|
||||
"pack_off": "{unit}: battery switched off, it is asked for 0 W",
|
||||
"pack_mode": "{unit}: battery mode changed",
|
||||
@@ -1118,6 +1143,7 @@ def status_samples() -> list:
|
||||
("row_battery_refuses", AMBER, row_battery_refuses("inverter-b", 1,
|
||||
True)),
|
||||
("row_circulating_check", GREEN, row_circulating_check(0, 0, 60)),
|
||||
("row_maint_waits", AMBER, row_maint_waits("2026-10-13")),
|
||||
]
|
||||
|
||||
|
||||
@@ -1148,6 +1174,8 @@ def samples() -> list:
|
||||
not_delivering("inverter-b", "inverter_b"),
|
||||
meter_frozen(600),
|
||||
meter_frozen(90),
|
||||
maint_failed("charge", 7),
|
||||
maint_failed("drain", 7, "inverter-b", "inverter_b"),
|
||||
]
|
||||
|
||||
|
||||
|
||||
@@ -1232,6 +1232,16 @@ def static_plan(opts: dict, since: datetime, until: datetime, *,
|
||||
profile, "fallback" if provisional else "static")
|
||||
|
||||
|
||||
def static_gated(opts: dict, now: datetime) -> bool:
|
||||
"""MAINT-13: is a fixed tariff set up, so that a cheap window can hold a
|
||||
charge back? False for no profile or one that cannot be used."""
|
||||
try:
|
||||
return bool(static_plan(opts, now, now + timedelta(days=MEAN_WINDOW_DAYS),
|
||||
now=now).has_prices)
|
||||
except ProfileInvalid:
|
||||
return False
|
||||
|
||||
|
||||
def static_status(opts: dict, now: datetime):
|
||||
"""(cheap, words) for the status page and for main.py's cheap-window flag.
|
||||
|
||||
|
||||
@@ -94,6 +94,7 @@ DEFAULTS = {
|
||||
"phase_started": None,
|
||||
"last_completed": None,
|
||||
"last_start_attempt": None,
|
||||
"last_failed": None,
|
||||
"sign_tripped": False,
|
||||
"sign_reason": "",
|
||||
"circ_tripped": False,
|
||||
@@ -171,7 +172,7 @@ MAINT_SCHEMA_KEY = "maint_schema_version"
|
||||
# silently stop being migrated - the same property `UNIT_STORE_KEYS` gives the
|
||||
# SAFETY-02 pair.
|
||||
MAINT_UNIT_KEYS = ("phase", "phase_started", "last_completed",
|
||||
"last_start_attempt")
|
||||
"last_start_attempt", "last_failed")
|
||||
|
||||
|
||||
def unit_key(unit: str, key: str) -> str:
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.15.0"
|
||||
version: "0.16.0"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
|
||||
@@ -0,0 +1,570 @@
|
||||
"""MAINT-13: a full pack that stops at 98-99 % is not a failed charge.
|
||||
`python3 test_maint13.py`
|
||||
|
||||
Graded here: the stall rule, the near-full timeout rule, the 7 day back-off
|
||||
after a failed cycle (and what ends it), the timeout counting only the minutes
|
||||
the price gate was open, restart and old-state-file behaviour, the notification
|
||||
(once), and the Controller wiring at one and two packs.
|
||||
See DECISIONS/MAINT-13-full-pack-is-complete.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import json
|
||||
import os
|
||||
import re
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
from pathlib import Path
|
||||
|
||||
from app import messages
|
||||
from app.maintenance import (
|
||||
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_STALL_MIN, CHARGE_TIMEOUT_MIN,
|
||||
CHARGE_WALL_TIMEOUT_MIN, DRAIN, FAIL_BACKOFF_DAYS, HOLD, IDLE,
|
||||
MaintConfig, Maintenance, arbitrate,
|
||||
)
|
||||
from app.main import Controller
|
||||
from app.store import (DEFAULTS, MAINT_UNIT_KEYS, Store, migrate_maint_keys,
|
||||
unit_key)
|
||||
|
||||
HERE = Path(__file__).resolve().parent
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
# The live site: target 100, shipped hold. Start hour 19 UTC for the schedule.
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC) # B's drain ended (live)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
"""Store's surface, no disk; times kept as the real Store keeps them."""
|
||||
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_charge(store=None, cfg=CFG, at=T0):
|
||||
"""A pack that has just finished its drain and is charging at `at`."""
|
||||
m = Maintenance(cfg, store or Mem())
|
||||
m.force_start(at)
|
||||
m.tick(at, 11.0) # drain complete -> charge
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` minutes for `minutes`; `soc` is a number or f(minute).
|
||||
Returns (the last result, the time after the run, the first non-CHARGE result)."""
|
||||
t, res, out = start, None, None
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
if out is None and res.phase != CHARGE:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out
|
||||
|
||||
|
||||
print("1. the stall rule: near full and no longer taking charge")
|
||||
# Live record: 99 % at 04:00, back to 98 % at 04:15, never 100.
|
||||
m = in_charge()
|
||||
res, end, out = run(m, T0 + 60 * MIN, 400, lambda i: 99.0 if i < 15 else 98.0)
|
||||
check("a pack that reaches 99 and falls back to 98 completes (HOLD) after "
|
||||
f"{CHARGE_STALL_MIN} min without a new high",
|
||||
out is not None and out[0].phase == HOLD)
|
||||
check("...at 60 min after the last new high (the 99), not before",
|
||||
out is not None and out[1] == T0 + 120 * MIN)
|
||||
check("...with one plain log line",
|
||||
out is not None and len(out[0].events) == 1
|
||||
and "takes no more charge at 98 %" in out[0].events[0])
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 59, 98.0)
|
||||
check("59 minutes flat is not enough", out is None and res.phase == CHARGE)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 61, lambda i: 97.0)
|
||||
check("target - 3 (97 of 100) counts as near full", out and out[0].phase == HOLD)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 300, lambda i: 96.0)
|
||||
check("target - 4 (96 of 100) does not complete however long it is flat",
|
||||
out is None)
|
||||
cfg99 = MaintConfig(enabled=True, start_hour=19, soc_target=99, hold_min=120)
|
||||
m = in_charge(cfg=cfg99)
|
||||
res, _, out = run(m, T0, 61, lambda i: 96.0)
|
||||
check("the shipped target 99 works the same way (96 is near full)",
|
||||
out and out[0].phase == HOLD)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 400, lambda i: min(99.0, 94.0 + i // 30))
|
||||
check("a pack still rising 1 point per 30 min is not stalled: it completes 60 "
|
||||
"min after the 99 at minute 150", out and out[1] == T0 + 210 * MIN)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 130, lambda i: 97.0 if i < 50 else (98.0 if i < 100 else 98.0))
|
||||
check("a new high resets the wait: 97 flat for 50 min, 98 at 50 min -> "
|
||||
"completes at 110, not 60", out and out[1] == T0 + 110 * MIN)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, 300, lambda i: 97.0, gate=False)
|
||||
check("minutes with the gate closed do not count as 'no more charge'",
|
||||
out is None)
|
||||
m = in_charge()
|
||||
_, t, _ = run(m, T0, 30, 98.0)
|
||||
_, t, _ = run(m, t, 120, 98.0, gate=False)
|
||||
res, _, out = run(m, t, 31, 98.0)
|
||||
check("30 open + 120 closed + 31 open minutes complete (the closed ones "
|
||||
"pause the count)", out and out[0].phase == HOLD)
|
||||
|
||||
print("2. SoC at the target completes at once")
|
||||
m = in_charge()
|
||||
r = m.tick(T0 + MIN, 100.0)
|
||||
check("100 of 100 -> HOLD on that tick", r.phase == HOLD)
|
||||
check("...with the old log line", "charge complete at 100 %" in r.events[0])
|
||||
m = in_charge(cfg=cfg99)
|
||||
check("99 of 99 -> HOLD", m.tick(T0 + MIN, 99.0).phase == HOLD)
|
||||
|
||||
print("3. a charge that runs out of time")
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, CHARGE_TIMEOUT_MIN + 10,
|
||||
lambda i: 60.0 + i / 55.0, step=1)
|
||||
check("still rising 1 point per 55 min (never 60 flat) and near full when the "
|
||||
"time is up -> counts as complete", out and out[0].phase == HOLD)
|
||||
check("...with one plain line saying so",
|
||||
out and len(out[0].events) == 1 and "charge time is up" in out[0].events[0]
|
||||
and "counts as done" in out[0].events[0])
|
||||
check("...and no failure is recorded", m.store.get_time("last_failed") is None)
|
||||
m = in_charge()
|
||||
res, _, out = run(m, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
|
||||
check("a pack stuck at 70 % fails when the time is up",
|
||||
out and out[0].phase == IDLE and out[0].failed == "charge")
|
||||
check("...once: the failure is on one tick, and the pack is idle after",
|
||||
m.phase == IDLE and m.tick(out[1] + MIN, 70.0).failed == "")
|
||||
check("...with the old technical line and one plain line",
|
||||
len(out[0].events) == 2 and "ABORT" in out[0].events[0]
|
||||
and "did not finish" in out[0].events[1]
|
||||
and f"{FAIL_BACKOFF_DAYS} days" in out[0].events[1])
|
||||
check("...and last_failed is set, last_completed is not",
|
||||
m.store.get_time("last_failed") == out[1]
|
||||
and m.store.get_time("last_completed") is None)
|
||||
|
||||
print("4. the back-off after a failed cycle")
|
||||
fail_at = out[1]
|
||||
day = lambda n: fail_at.replace(hour=19, minute=0) + timedelta(days=n)
|
||||
check("the next day at the start hour: no cycle (it would begin with a drain)",
|
||||
not m.wants_start(day(1)) and m.tick(day(1), 70.0).phase == IDLE)
|
||||
check("every day for 6 days: still no cycle",
|
||||
all(not m.wants_start(day(n)) for n in range(1, 7)))
|
||||
r = [m.tick(day(n), 70.0) for n in range(1, 7)]
|
||||
check("...and tick() keeps the pack idle and silent",
|
||||
all(x.phase == IDLE and not x.events and x.failed == "" for x in r))
|
||||
until = m.backoff_until(day(1))
|
||||
check("backoff_until() names the date, 7 days after the failure",
|
||||
until == fail_at + timedelta(days=FAIL_BACKOFF_DAYS))
|
||||
check("...it holds one minute before and is over at that minute",
|
||||
m.backoff_until(until - MIN) == until and m.backoff_until(until) is None)
|
||||
check("at 7 days, in the start hour, the pack wants to start again",
|
||||
m.backoff_until(until) is None
|
||||
and m.wants_start(until.replace(hour=19, minute=5)))
|
||||
check("a forced start ignores the back-off",
|
||||
m.force_start(day(1)) and m.phase == DRAIN)
|
||||
m2 = in_charge()
|
||||
run(m2, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
|
||||
m2.force_start(day(2))
|
||||
m2.tick(day(2) + MIN, 11.0)
|
||||
res, _, out2 = run(m2, day(2) + 2 * MIN, 400, 100.0)
|
||||
check("a forced cycle that completes ends the back-off",
|
||||
out2 and out2[0].phase == HOLD)
|
||||
m2.tick(out2[1] + 130 * MIN, 100.0)
|
||||
check("...(the hold completes, last_completed is set)",
|
||||
m2.store.get_time("last_completed") is not None
|
||||
and m2.backoff_until(day(3)) is None)
|
||||
m3 = in_charge()
|
||||
m3.store.set_time("last_failed", T0)
|
||||
m3.abort(T0 + MIN, "operator")
|
||||
check("an operator abort is not a failure and starts no back-off",
|
||||
m3.store.get_time("last_failed") == T0
|
||||
and in_charge().store.get_time("last_failed") is None)
|
||||
m4 = Maintenance(CFG, Mem())
|
||||
m4.force_start(T0)
|
||||
r = m4.tick(T0 + timedelta(minutes=721), 40.0)
|
||||
check("a drain that times out is a failure too, with the same back-off",
|
||||
r.failed == "drain" and m4.store.get_time("last_failed") is not None
|
||||
and not m4.wants_start(day(1)))
|
||||
|
||||
print("5. only the minutes the pack was allowed to charge count")
|
||||
m = in_charge()
|
||||
# 5 min steps: one tick counts at most 5 min, so this is the same count as
|
||||
# 1 min steps in a fifth of the ticks.
|
||||
res, t, out = run(m, T0, CHARGE_TIMEOUT_MIN * 2, 70.0, gate=False, step=5)
|
||||
check("72 h with the gate closed: not timed out", out is None and m.phase == CHARGE)
|
||||
res, t, out = run(m, t, CHARGE_TIMEOUT_MIN - 5, 70.0, step=5)
|
||||
check("...and 35 h 55 min open on top: still charging", out is None)
|
||||
res, t, out = run(m, t, 10, 70.0)
|
||||
check("...36 h of open time in all: the charge fails", out and out[0].failed == "charge")
|
||||
m = in_charge()
|
||||
WALL = T0 + CHARGE_WALL_TIMEOUT_MIN * MIN
|
||||
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 70.0, gate=False, step=5)
|
||||
check("a gate that never opens still ends in a failure after 7 days (not before)",
|
||||
out and out[0].failed == "charge" and WALL < out[1] <= WALL + 5 * MIN)
|
||||
m = in_charge()
|
||||
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 98.0, gate=False, step=5)
|
||||
check("...or in a complete charge when the pack is near full",
|
||||
out and out[0].phase == HOLD and WALL < out[1] <= WALL + 5 * MIN)
|
||||
m = in_charge()
|
||||
res, t, out = run(m, T0, 10, 70.0)
|
||||
before = m._trk["open_min"]
|
||||
res = m.tick(t + 2 * timedelta(hours=1), 70.0)
|
||||
check("a gap in the ticks (add-on down) counts for exactly 5 minutes (the cap)",
|
||||
abs(m._trk["open_min"] - before - 5.0) < 1e-9)
|
||||
m.tick(t + 2 * timedelta(hours=1) + 2 * MIN, 70.0)
|
||||
check("...and a 2 minute step counts 2", abs(m._trk["open_min"] - before - 7.0) < 1e-9)
|
||||
_t = t + 2 * timedelta(hours=1) + 2 * MIN
|
||||
m.tick(_t - 10 * MIN, 70.0) # the clock steps back 10 min
|
||||
check("...and a step back in time counts nothing (not minus)",
|
||||
abs(m._trk["open_min"] - before - 7.0) < 1e-9)
|
||||
|
||||
print("6. restarts and old state files")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
st = Store(path)
|
||||
m = Maintenance(CFG, st)
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
_, t, out = run(m, T0, 60, 70.0, gate=False) # 60 min waiting
|
||||
_, t, out = run(m, t, 40, 70.0) # 40 min charging
|
||||
open_before = m._trk["open_min"]
|
||||
# a fresh process on the same file
|
||||
m_b = Maintenance(CFG, Store(path))
|
||||
r = m_b.tick(t + MIN, 70.0)
|
||||
check("a restart mid-charge keeps the open minutes (40 of 100 min; within "
|
||||
"the 5 min save interval), not the 100 wall-clock minutes",
|
||||
m_b.phase == CHARGE
|
||||
and open_before - 6 <= m_b._trk["open_min"] <= open_before + 2
|
||||
and m_b._trk["open_min"] < 60)
|
||||
_, t2, out = run(m_b, t + 2 * MIN, CHARGE_TIMEOUT_MIN - 30, 70.0, step=5)
|
||||
check("...so the timeout comes after 36 h in all, not 36 h from the restart",
|
||||
out is not None and out[0].failed == "charge")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.store.set_time("last_failed", T0)
|
||||
m_c = Maintenance(CFG, Store(path))
|
||||
check("a restart mid back-off keeps it (last_failed is in the file)",
|
||||
m_c.backoff_until(T0 + timedelta(days=3)) == T0 + timedelta(days=7)
|
||||
and not m_c.wants_start((T0 + timedelta(days=3)).replace(hour=19)))
|
||||
check("...and the state file is plain JSON",
|
||||
isinstance(json.load(open(path)).get("last_failed"), str))
|
||||
old = {"phase": "charge",
|
||||
"phase_started": (T0 - timedelta(hours=35)).isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None,
|
||||
"auto": True}
|
||||
path2 = os.path.join(d, "old.json")
|
||||
json.dump(old, open(path2, "w"))
|
||||
mo = Maintenance(CFG, Store(path2))
|
||||
check("a state file from before this change loads with no failure and no "
|
||||
"charge record", mo.backoff_until(T0) is None
|
||||
and mo.store.get("charge_track") is None and mo.phase == CHARGE)
|
||||
r = mo.tick(T0, 70.0)
|
||||
check("...a charge in progress counts the hours it already ran (35 h)",
|
||||
r.phase == CHARGE and 34 * 60 < mo._trk["open_min"] < 36 * 60)
|
||||
res, _, out = run(mo, T0 + MIN, 120, 70.0)
|
||||
check("...so it fails when the 36 h are up, as before",
|
||||
out and out[0].failed == "charge")
|
||||
# A record left by another charge (an add-on rolled back and forward
|
||||
# again does not clear it) must not be read as this charge's.
|
||||
stale = {"phase": "charge",
|
||||
"phase_started": (T0 - timedelta(hours=2)).isoformat(),
|
||||
"charge_track": {"since": (T0 - timedelta(days=30)).isoformat(),
|
||||
"open_min": 2000.0, "flat_min": 59.0,
|
||||
"best": 99.0, "at": None}}
|
||||
ms = Maintenance(CFG, Mem(stale))
|
||||
r = ms.tick(T0, 98.0)
|
||||
check("a charge record from another charge is ignored: this charge counts "
|
||||
"its own 2 h and its own best",
|
||||
r.phase == CHARGE and 119 < ms._trk["open_min"] < 121
|
||||
and ms._trk["flat_min"] == 0.0 and ms._trk["best"] == 98.0)
|
||||
mi = Maintenance(CFG, Store(os.path.join(d, "none.json")))
|
||||
check("no state file: due, no back-off", mi.due(T0) and mi.backoff_until(T0) is None)
|
||||
|
||||
print("7. two packs (N=2)")
|
||||
a, b = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"), \
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
|
||||
b.force_start(T0)
|
||||
b.tick(T0, 11.0)
|
||||
_, t, out = run(b, T0, CHARGE_TIMEOUT_MIN + 10, 70.0)
|
||||
slot = datetime(2026, 10, 7, 19, 5, tzinfo=UTC)
|
||||
check("B failed: B is backed off, A (due) is not",
|
||||
out and out[0].failed == "charge" and not b.wants_start(slot)
|
||||
and a.wants_start(slot))
|
||||
check("...so A takes the slot, and B is not named as waiting for anyone",
|
||||
arbitrate([a, b], slot) == ["", ""])
|
||||
a.force_start(slot)
|
||||
check("...and while A cycles, B is held as before",
|
||||
"inverter-a" in arbitrate([a, b], slot + 3 * MIN)[1])
|
||||
check("B's failure is under B's own keys, not A's",
|
||||
b.store.get_time("last_failed") is not None
|
||||
and a.store.get_time("last_failed") is None)
|
||||
mst = Mem({"last_failed": T0.isoformat(), "phase": "idle"})
|
||||
migrate_maint_keys(mst, "inverter-a", ["inverter-a", "inverter-b"])
|
||||
check("going from one pack to two moves the back-off to the first pack",
|
||||
mst.data.get(unit_key("inverter-a", "last_failed")) == T0.isoformat()
|
||||
and "last_failed" in MAINT_UNIT_KEYS)
|
||||
|
||||
|
||||
print("8. the Controller: gate, notification, status row")
|
||||
|
||||
|
||||
class Hass:
|
||||
def __init__(self, numbers, limits):
|
||||
self.numbers, self.limits_by, self.calls = dict(numbers), dict(limits), []
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
v = self.numbers.get(entity)
|
||||
return None if v is None else (-v if invert else v)
|
||||
|
||||
async def limits(self, entity):
|
||||
return self.limits_by.get(entity, (None, None, None))
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
return True
|
||||
|
||||
async def call(self, domain, service, data):
|
||||
self.calls.append((domain, service, data))
|
||||
return True
|
||||
|
||||
|
||||
class Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
OPTS1 = dict(setpoint_entity="number.sp_a", soc_entity="sensor.soc_a",
|
||||
batt_entity="sensor.batt_a", meter_source="off",
|
||||
meter_entity="sensor.grid", max_w=5000.0, gain=0.6, slew_w=6000,
|
||||
deadband_w=15, target_grid_w=0, step_w=10, heartbeat_s=10,
|
||||
stale_input_s=15, maintenance_discharge_w=2000,
|
||||
maintenance_charge_w=2000, maintenance_enabled=True,
|
||||
maintenance_soc_target=100,
|
||||
price_now_entity="sensor.p_now", price_avg_entity="sensor.p_avg")
|
||||
OPTS2 = {k: v for k, v in OPTS1.items()
|
||||
if k not in ("setpoint_entity", "soc_entity", "batt_entity")}
|
||||
OPTS2["inverters"] = [
|
||||
dict(name="inverter-a", setpoint_entity="number.sp_a",
|
||||
soc_entity="sensor.soc_a", batt_entity="sensor.batt_a", max_w=5000.0),
|
||||
dict(name="inverter-b", setpoint_entity="number.sp_b",
|
||||
soc_entity="sensor.soc_b", batt_entity="sensor.batt_b", max_w=3000.0)]
|
||||
|
||||
|
||||
def controller(opts, cheap, soc_a=70.0, soc_b=70.0):
|
||||
p_now, p_avg = (0.05, 0.10) if cheap else (0.20, 0.10)
|
||||
hass = Hass({"sensor.grid": 800.0, "sensor.soc_a": soc_a,
|
||||
"sensor.batt_a": 0.0, "sensor.soc_b": soc_b,
|
||||
"sensor.batt_b": 0.0, "sensor.p_now": p_now,
|
||||
"sensor.p_avg": p_avg},
|
||||
{"number.sp_a": (-5000.0, 5000.0, 1.0),
|
||||
"number.sp_b": (-3000.0, 3000.0, 1.0)})
|
||||
c = Controller(dict(opts), hass, Mem(), Pub(), stop=asyncio.Event())
|
||||
for inv in c.inverters:
|
||||
inv.dev_min, inv.dev_max = -inv.max_w, inv.max_w
|
||||
c.auto = True
|
||||
return c, hass
|
||||
|
||||
|
||||
def one_cycle(c):
|
||||
async def go():
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
asyncio.run(go())
|
||||
|
||||
|
||||
def put_in_charge(c, which, hours_ago, open_min):
|
||||
now = datetime.now(UTC)
|
||||
m = c.maints[which]
|
||||
m.store.set("phase", CHARGE)
|
||||
m.store.set_time("phase_started", now - timedelta(hours=hours_ago))
|
||||
m.store.set("charge_track", {
|
||||
"since": m.store.get("phase_started"), "open_min": open_min,
|
||||
"flat_min": 0.0, "best": 70.0,
|
||||
"at": (now - timedelta(minutes=3)).isoformat()})
|
||||
return m
|
||||
|
||||
|
||||
def notes(h):
|
||||
return [x for x in h.calls if x[0] == "persistent_notification"]
|
||||
|
||||
|
||||
for cheap in (True, False):
|
||||
c, h = controller(OPTS1, cheap)
|
||||
m = put_in_charge(c, 0, 5, 100.0)
|
||||
one_cycle(c)
|
||||
got = m._trk["open_min"] - 100.0
|
||||
check(f"N=1, price gate {'open' if cheap else 'closed'}: the Controller "
|
||||
f"{'adds' if cheap else 'does not add'} the 3 minutes since the last "
|
||||
f"tick to the charging time (+{got:.1f})",
|
||||
(2.5 < got < 3.5) if cheap else abs(got) < 0.01)
|
||||
|
||||
c, h = controller(OPTS1, True)
|
||||
m = put_in_charge(c, 0, 40, CHARGE_TIMEOUT_MIN + 1)
|
||||
one_cycle(c)
|
||||
n = notes(h)
|
||||
check("N=1: a charge past its time at 70 % ends in IDLE with ONE notification",
|
||||
m.phase == IDLE and len(n) == 1
|
||||
and n[0][2]["notification_id"] == "goodwe_maint_failed_battery"
|
||||
and n[0][2]["title"] == "Battery cycle did not finish")
|
||||
one_cycle(c)
|
||||
one_cycle(c)
|
||||
check("...and later cycles send no second one, and start no drain",
|
||||
len(notes(h)) == 1 and m.phase == IDLE)
|
||||
check("...the status page says when it waits until",
|
||||
any(k == "Maintenance paused" and "Waits until" in v
|
||||
for k, v in c.status_payload()["rows"]))
|
||||
c0, _h0 = controller(OPTS1, True)
|
||||
check("...and has no such row when nothing failed",
|
||||
not any(k == "Maintenance paused" for k, v in c0.status_payload()["rows"]))
|
||||
|
||||
c, h = controller(OPTS2, True)
|
||||
m = put_in_charge(c, 1, 40, CHARGE_TIMEOUT_MIN + 1)
|
||||
one_cycle(c)
|
||||
n = notes(h)
|
||||
check("N=2: pack B fails, B alone is told, by name, under its own id",
|
||||
c.maints[1].phase == IDLE and c.maints[0].phase == IDLE and len(n) == 1
|
||||
and n[0][2]["notification_id"] == "goodwe_maint_failed_inverter_b"
|
||||
and "inverter-b" in n[0][2]["message"])
|
||||
check("...and its failure is on B's keys",
|
||||
c.maints[1].store.get_time("last_failed") is not None
|
||||
and c.maints[0].store.get_time("last_failed") is None)
|
||||
|
||||
# a site with no price entities and no fixed tariff: nothing holds the charge back
|
||||
NOTARIFF = {k: v for k, v in OPTS1.items()
|
||||
if k not in ("price_now_entity", "price_avg_entity")}
|
||||
c, h = controller(NOTARIFF, False)
|
||||
m = put_in_charge(c, 0, 5, 100.0)
|
||||
one_cycle(c)
|
||||
got = m._trk["open_min"] - 100.0
|
||||
check("N=1, no tariff and no price entities: the gate counts as open, so the "
|
||||
f"3 minutes count (+{got:.1f}) although `cheap` is false",
|
||||
not c.cheap and 2.5 < got < 3.5)
|
||||
c, h = controller(NOTARIFF, False)
|
||||
m = put_in_charge(c, 0, 40, CHARGE_TIMEOUT_MIN + 1)
|
||||
one_cycle(c)
|
||||
check("...and a pack past its charging time there fails at once (not 7 days)",
|
||||
m.phase == IDLE and len(notes(h)) == 1)
|
||||
# a site with a price provider (TARIFF-11) and no fixed tariff: the provider's
|
||||
# plan reaches only the Tariff row, never `cheap`, so no cheap window ever
|
||||
# opens a grid top-up there. Like the site above, nothing gate-like holds the
|
||||
# charge back, and the time counts.
|
||||
PROVIDER = dict(NOTARIFF, price_provider="generic_dayahead", static_profile="")
|
||||
c, h = controller(PROVIDER, False)
|
||||
m = put_in_charge(c, 0, 5, 100.0)
|
||||
one_cycle(c)
|
||||
got = m._trk["open_min"] - 100.0
|
||||
check("N=1, price provider and no fixed tariff: not a gate (`cheap` is never "
|
||||
f"set from the provider), so the 3 minutes count (+{got:.1f})",
|
||||
c._price_gated is False and not c.cheap
|
||||
and c._charge_gate_open(c.inverters[0]) is True and 2.5 < got < 3.5)
|
||||
def read(c):
|
||||
asyncio.run(c.read_inputs())
|
||||
|
||||
|
||||
c, h = controller(OPTS1, False)
|
||||
read(c)
|
||||
c.inverters[0].batt = -800.0
|
||||
check("price gate closed but the pack is taking 800 W (sun): gate open",
|
||||
c._charge_gate_open(c.inverters[0]) is True)
|
||||
c.inverters[0].batt = -10.0
|
||||
check("...closed and about idle: gate closed",
|
||||
c._charge_gate_open(c.inverters[0]) is False)
|
||||
c.inverters[0].batt = None
|
||||
check("...no battery reading: gate closed", c._charge_gate_open(c.inverters[0]) is False)
|
||||
c, h = controller(OPTS1, True)
|
||||
read(c)
|
||||
check("price gate open: gate open", c._charge_gate_open(c.inverters[0]) is True)
|
||||
PROFILE = json.dumps({"periods": [
|
||||
{"name": "day", "from": "07:00", "to": "22:00", "days": "all",
|
||||
"eur_per_kwh": 0.29},
|
||||
{"name": "night", "from": "22:00", "to": "07:00", "days": "all",
|
||||
"eur_per_kwh": 0.19}]})
|
||||
c, h = controller(dict(NOTARIFF, price_provider="off", static_profile=PROFILE),
|
||||
False)
|
||||
read(c)
|
||||
check("a fixed tariff set up counts as a gate: outside its cheap hours a pack "
|
||||
"that is not charging is closed, inside them it is open",
|
||||
c._price_gated is True
|
||||
and c._charge_gate_open(c.inverters[0]) is c.cheap)
|
||||
import app.main as main_mod # noqa: E402
|
||||
_real_gated, _calls = main_mod.static_gated, []
|
||||
main_mod.static_gated = lambda o, now: _calls.append(now) or _real_gated(o, now)
|
||||
try:
|
||||
c._gated_key = None
|
||||
read(c)
|
||||
read(c)
|
||||
read(c)
|
||||
c._static_gated(c.o, datetime.now(UTC) + timedelta(hours=1))
|
||||
finally:
|
||||
main_mod.static_gated = _real_gated
|
||||
check("...worked out once an hour, not on every tick (3 reads in one hour = 1 "
|
||||
f"build; a new hour = 1 more): {len(_calls)} builds",
|
||||
len(_calls) == 2 and c._price_gated is True)
|
||||
|
||||
# the save timer is reset on a phase change
|
||||
mm = in_charge()
|
||||
mm.tick(T0 + MIN, 70.0)
|
||||
saved_before = mm._trk_saved
|
||||
mm.abort(T0 + 2 * MIN, "operator")
|
||||
check("leaving CHARGE resets the save timer along with the record",
|
||||
saved_before is not None and mm._trk is None and mm._trk_saved is None)
|
||||
|
||||
print("9. the words")
|
||||
en, nl = messages.maint_failed("charge", 7), messages.maint_failed("drain", 7)
|
||||
for n_ in (en, nl):
|
||||
print(" " + n_.title + " | " + n_.body + " | " + n_.body_nl)
|
||||
check("EN charge text", en.body == "The battery did not fill up, so its cycle "
|
||||
"stopped and tries again in 7 days.")
|
||||
check("EN drain text", nl.body == "The battery did not empty, so its cycle "
|
||||
"stopped and tries again in 7 days.")
|
||||
check("NL texts", en.body_nl == "Batterijcyclus niet afgerond. De batterij "
|
||||
"raakte niet vol, dus de cyclus is gestopt en probeert het over 7 dagen "
|
||||
"opnieuw." and nl.body_nl.endswith("raakte niet leeg, dus de cyclus is "
|
||||
"gestopt en probeert het over 7 dagen opnieuw."))
|
||||
check("the notification carries EN, NL and the Details line, in that order",
|
||||
re.fullmatch(r"The battery .*\n\nBatterijcyclus .*\n\nDetails: .*",
|
||||
en.data()["message"], re.S) is not None)
|
||||
check("the DOCS section and table row exist",
|
||||
"### Battery cycle did not finish" in (HERE / "DOCS.md").read_text()
|
||||
and "goodwe_maint_failed_<name>" in (HERE / "DOCS.md").read_text())
|
||||
check("no new option: the numbers are constants",
|
||||
(CHARGE_NEAR_FULL_PCT, CHARGE_STALL_MIN, FAIL_BACKOFF_DAYS)
|
||||
== (3, 60, 7))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all passed")
|
||||
@@ -0,0 +1,403 @@
|
||||
"""MAINT-14: maintenance with no SoC reading.
|
||||
`python3 test_maint14.py`
|
||||
|
||||
Graded here: charge and drain with SoC None at one and two packs - the charge
|
||||
timeout and 7 day backstop still run (failure, or done when the last SoC was
|
||||
>= target - 3), the drain holds at 0 W and times out, SoC coming back resumes
|
||||
normally with no back-off, the log lines (once per episode), a restart while the
|
||||
SoC is missing, and one pack's missing SoC leaving the other pack alone.
|
||||
See DECISIONS/MAINT-14-no-soc-in-maintenance.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.maintenance import (
|
||||
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_TIMEOUT_MIN, CHARGE_WALL_TIMEOUT_MIN,
|
||||
DRAIN, DRAIN_TIMEOUT_MIN, FAIL_BACKOFF_DAYS, HOLD, IDLE, NOSOC_NOTE_MIN,
|
||||
MaintConfig, Maintenance, arbitrate,
|
||||
)
|
||||
from app.store import DEFAULTS, Store
|
||||
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_drain(store=None, unit=None, at=T0):
|
||||
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
|
||||
m.force_start(at)
|
||||
assert m.phase == DRAIN
|
||||
return m
|
||||
|
||||
|
||||
def in_charge(store=None, unit=None, at=T0):
|
||||
m = in_drain(store, unit, at)
|
||||
m.tick(at, 11.0)
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` min; returns (last result, end time, first result that
|
||||
is not the starting phase with its time, all events)."""
|
||||
ph, t, res, out, ev = m.phase, start, None, None, []
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
ev += res.events
|
||||
if out is None and res.phase != ph:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out, ev
|
||||
|
||||
|
||||
print("1. charge with no SoC")
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, 600, None)
|
||||
check("it keeps charging: the loop owns the setpoint, no start of a new phase",
|
||||
out is None and res.phase == CHARGE and res.charge_only
|
||||
and not res.owns_setpoint)
|
||||
|
||||
m = in_charge()
|
||||
run(m, T0, 60, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 60 * MIN, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
check("the charge timeout still runs: it fails once the time is up (last SoC 60)",
|
||||
out and out[0].failed == "charge" and out[0].phase == IDLE)
|
||||
check("...with the MAINT-13 back-off and its one plain line",
|
||||
m.store.get_time("last_failed") is not None
|
||||
and sum("did not finish" in e for e in ev) == 1
|
||||
and f"{FAIL_BACKOFF_DAYS} days" in ev[-1])
|
||||
check("...it took 36 h of allowed time from the charge start, not more",
|
||||
out and out[1] <= T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 10))
|
||||
check("...and the pack does not want a start in the back-off",
|
||||
not m.wants_start((T0 + timedelta(days=3)).replace(hour=19)))
|
||||
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
check("never saw a SoC: the timeout is a failure, not 'done'",
|
||||
out and out[0].failed == "charge")
|
||||
|
||||
for last in (97.0, 99.0):
|
||||
m = in_charge()
|
||||
run(m, T0, 10, last)
|
||||
res, _, out, ev = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check(f"last SoC {last:.0f} (>= target - {CHARGE_NEAR_FULL_PCT}): time up counts as done",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and m.store.get_time("last_failed") is None)
|
||||
check("...one plain line says so",
|
||||
sum("counts as done" in e for e in ev) == 1
|
||||
and f"{last:.0f} %" in " ".join(ev))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 96.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check("last SoC 96 (below target - 3): time up is a failure",
|
||||
out and out[0].failed == "charge")
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 99.0)
|
||||
run(m, T0 + 10 * MIN, 10, 50.0)
|
||||
res, _, out, _ = run(m, T0 + 20 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
check("'last seen' is the last reading, not the best (99 then 50: failure)",
|
||||
out and out[0].failed == "charge")
|
||||
|
||||
print("2. the 7 day backstop, with the gate shut")
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
check("gate never opens, last SoC 70: failure at 7 days",
|
||||
out and out[0].failed == "charge"
|
||||
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN)
|
||||
and out[1] <= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN + 10))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 98.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
check("gate never opens, last SoC 98: done at 7 days",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and out[1] >= T0 + timedelta(minutes=CHARGE_WALL_TIMEOUT_MIN))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
res, _, out, _ = run(m, T0 + 10 * MIN, 3000, None, gate=False, step=5)
|
||||
check("gate shut, no SoC: the open-time clock does not run (no early end)",
|
||||
out is None)
|
||||
|
||||
print("3. SoC comes back mid-charge")
|
||||
m = in_charge()
|
||||
run(m, T0, 30, 80.0)
|
||||
run(m, T0 + 30 * MIN, 600, None)
|
||||
res, _, out, _ = run(m, T0 + 630 * MIN, 5, 80.0)
|
||||
check("normal behaviour resumes: still charging, nothing recorded",
|
||||
out is None and res.phase == CHARGE
|
||||
and m.store.get_time("last_failed") is None)
|
||||
res, _, out, _ = run(m, T0 + 640 * MIN, 10, 100.0)
|
||||
check("...and it completes at the target as usual",
|
||||
out and out[0].phase == HOLD and m.store.get_time("last_failed") is None)
|
||||
m = in_charge()
|
||||
run(m, T0, 30, 98.0)
|
||||
run(m, T0 + 30 * MIN, 600, None)
|
||||
res, _, out, _ = run(m, T0 + 630 * MIN, 30, 98.0)
|
||||
check("the stall wait paused while the SoC was missing (30 min flat after the "
|
||||
"gap is not 60)", out is None)
|
||||
res, _, out, _ = run(m, T0 + 660 * MIN, 40, 98.0)
|
||||
check("...and completes once 60 min flat are in", out and out[0].phase == HOLD)
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN - 100, None)
|
||||
res, _, out, _ = run(m, T0 + (CHARGE_TIMEOUT_MIN - 90) * MIN, 5, 70.0)
|
||||
check("a gap just before the limit then a reading: no failure, no back-off",
|
||||
out is None and m.store.get_time("last_failed") is None)
|
||||
|
||||
print("4. drain with no SoC")
|
||||
m = in_drain()
|
||||
run(m, T0, 30, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 30 * MIN, 60, None)
|
||||
check("DRAIN holds at 0 W, owned by maintenance, the same as HOLD",
|
||||
out is None and res.phase == DRAIN and res.owns_setpoint
|
||||
and res.setpoint_w == 0.0 and not res.charge_only)
|
||||
hold = in_charge()
|
||||
hold.tick(T0 + MIN, 100.0)
|
||||
hr = hold.tick(T0 + 2 * MIN, None)
|
||||
check("...the same answer as HOLD gives",
|
||||
(hr.owns_setpoint, hr.setpoint_w) == (res.owns_setpoint, res.setpoint_w))
|
||||
check("never above 0 W on any missing tick",
|
||||
all(m.tick(T0 + (100 + i) * MIN, None).setpoint_w == 0.0 for i in range(30)))
|
||||
check("one plain line that the drain holds, once, not per tick",
|
||||
sum("drain holds at 0 W" in e for e in ev) == 1)
|
||||
check("one plain line after the threshold, once",
|
||||
sum("no battery level for" in e for e in ev) == 1
|
||||
and f"{NOSOC_NOTE_MIN} min" in " ".join(ev))
|
||||
m = in_drain()
|
||||
res, _, out, ev = run(m, T0, NOSOC_NOTE_MIN - 1, None)
|
||||
check("under the threshold the 'no level for long' line is not said",
|
||||
not any("no battery level for" in e for e in ev))
|
||||
m = in_drain()
|
||||
res, _, out, ev = run(m, T0, DRAIN_TIMEOUT_MIN + 10, None)
|
||||
check("the 12 h drain timeout still runs: failure with back-off",
|
||||
out and out[0].failed == "drain" and out[0].phase == IDLE
|
||||
and out[1] > T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN)
|
||||
and m.store.get_time("last_failed") is not None)
|
||||
m = in_drain()
|
||||
run(m, T0, 60, None)
|
||||
res, _, out, _ = run(m, T0 + 60 * MIN, 5, 60.0)
|
||||
check("SoC back: the drain continues at the drain rate",
|
||||
out is None and res.phase == DRAIN and res.owns_setpoint
|
||||
and res.setpoint_w == CFG.discharge_w)
|
||||
res, _, out, _ = run(m, T0 + 70 * MIN, 5, 10.0)
|
||||
check("...and ends at the floor as usual",
|
||||
out and out[0].phase == CHARGE and m.store.get_time("last_failed") is None)
|
||||
m = in_drain()
|
||||
run(m, T0, 60, None)
|
||||
run(m, T0 + 60 * MIN, 5, 60.0)
|
||||
res, _, out, ev = run(m, T0 + 70 * MIN, 5, None)
|
||||
check("a second episode says its lines again",
|
||||
any("drain holds at 0 W" in e for e in ev))
|
||||
|
||||
print("5. the log is once per episode")
|
||||
m = in_charge()
|
||||
res, _, out, ev = run(m, T0, 300, None)
|
||||
check("a 5 h charge episode: exactly one 'no level for long' line, none per tick",
|
||||
len(ev) == 1 and "no battery level for" in ev[0])
|
||||
run(m, T0 + 300 * MIN, 3, 70.0)
|
||||
res, _, out, ev = run(m, T0 + 303 * MIN, 60, None)
|
||||
check("...and one more for a new episode", len(ev) == 1)
|
||||
m = in_charge()
|
||||
res, _, out, ev = run(m, T0, 5, None)
|
||||
check("a 5 min gap says nothing", ev == [])
|
||||
|
||||
print("5b. the words per phase")
|
||||
m = in_charge()
|
||||
m.tick(T0 + MIN, 100.0)
|
||||
_, _, _, ev = run(m, T0 + 2 * MIN, 30, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("HOLD: the line exists and claims no time limit",
|
||||
len(note) == 1 and "time limit" not in note[0] and "waits" in note[0])
|
||||
m = in_charge()
|
||||
_, _, _, ev = run(m, T0, 30, None)
|
||||
check("charge keeps its wording", any("time limit of the charge" in e for e in ev))
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 70.0)
|
||||
_, _, out, ev = run(m, T0 + 10 * MIN, CHARGE_WALL_TIMEOUT_MIN + 30, None,
|
||||
gate=False, step=5)
|
||||
fail = [e for e in ev if "ABORT" in e]
|
||||
check("7-day backstop: the reason names the 7-day limit, not '0 h'",
|
||||
len(fail) == 1 and "7-day limit" in fail[0] and "0 h" not in fail[0])
|
||||
m = in_charge()
|
||||
_, _, out, ev = run(m, T0, CHARGE_TIMEOUT_MIN + 10, None)
|
||||
fail = [e for e in ev if "ABORT" in e]
|
||||
check("charge-time limit: the reason gives the hours of charging time",
|
||||
len(fail) == 1 and "36 h of charging time" in fail[0])
|
||||
m = in_charge()
|
||||
run(m, T0, 10, 98.0)
|
||||
_, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
_, _, _, ev = run(m, out[1] + MIN, 30, None)
|
||||
check("charge done with no SoC, then HOLD with no SoC: a new episode, so the "
|
||||
"HOLD line is said", out[0].phase == HOLD
|
||||
and sum("hold waits" in e for e in ev) == 1)
|
||||
|
||||
print("6. restart while the SoC is missing")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
run(m, T0, 97, lambda i: 90.0 if i < 96 else 98.0) # 98 seen 1 min ago
|
||||
run(m, T0 + 97 * MIN, 3, None) # SoC lost; state saved at once
|
||||
t = T0 + 100 * MIN # restart 3 min after the loss, before the next 5 min save
|
||||
m2 = Maintenance(CFG, Store(path))
|
||||
r = m2.tick(t, None)
|
||||
check("a fresh process reads charge, and still charges", m2.phase == CHARGE
|
||||
and r.phase == CHARGE and r.charge_only)
|
||||
check("...with the open minutes and the last SoC seen from the file",
|
||||
m2._trk is not None and m2._trk["last"] == 98.0
|
||||
and 92 <= m2._trk["open_min"] <= 105)
|
||||
res, _, out, _ = run(m2, t + MIN, CHARGE_TIMEOUT_MIN, None, step=5)
|
||||
check("...so the timeout counts from the first charge minute and, with the "
|
||||
"last SoC 98, completes (no failure)",
|
||||
out and out[0].phase == HOLD and out[0].failed == ""
|
||||
and out[1] < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 60))
|
||||
# drain: restart keeps it at 0 W and keeps the clock
|
||||
path2 = os.path.join(d, "s2.json")
|
||||
md = Maintenance(CFG, Store(path2))
|
||||
md.force_start(T0)
|
||||
md.tick(T0 + 100 * MIN, None)
|
||||
md2 = Maintenance(CFG, Store(path2))
|
||||
r = md2.tick(T0 + 101 * MIN, None)
|
||||
check("a drain restarted with no SoC holds at 0 W", md2.phase == DRAIN
|
||||
and r.setpoint_w == 0.0 and r.owns_setpoint)
|
||||
res, _, out, _ = run(md2, T0 + 102 * MIN, DRAIN_TIMEOUT_MIN, None, step=5)
|
||||
check("...and the 12 h clock is from the drain start, not the restart",
|
||||
out and out[0].failed == "drain"
|
||||
and out[1] <= T0 + timedelta(minutes=DRAIN_TIMEOUT_MIN + 10))
|
||||
# a charge restarted with no record of any SoC (old state file)
|
||||
old = {"phase": "charge", "phase_started": (T0 - timedelta(hours=35)).isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None, "auto": True}
|
||||
import json
|
||||
path3 = os.path.join(d, "s3.json")
|
||||
json.dump(old, open(path3, "w"))
|
||||
mo = Maintenance(CFG, Store(path3))
|
||||
res, _, out, _ = run(mo, T0, 120, None)
|
||||
check("an old state file with no SoC seen: the charge fails at 36 h",
|
||||
out and out[0].failed == "charge")
|
||||
# a MAINT-13 state file: charge_track with a best but no `last`
|
||||
since = (T0 - timedelta(hours=35)).isoformat()
|
||||
m13 = dict(old, phase_started=since, charge_track={
|
||||
"since": since, "open_min": 2100.0, "flat_min": 0.0, "best": 99.0,
|
||||
"at": (T0 - MIN).isoformat()})
|
||||
path4 = os.path.join(d, "s4.json")
|
||||
json.dump(m13, open(path4, "w"))
|
||||
mo = Maintenance(CFG, Store(path4))
|
||||
res, _, out, _ = run(mo, T0, 120, None)
|
||||
check("a MAINT-13 state file (no last SoC): no crash, the charge fails at "
|
||||
"36 h (best is not last)", out and out[0].failed == "charge")
|
||||
|
||||
print("7. two packs")
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a.force_start(T0)
|
||||
# the twin site: the same two packs, A healthy (SoC 60, still above the floor)
|
||||
a_ok, b_alone = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a_ok.force_start(T0)
|
||||
same = True
|
||||
for i in range(0, 120, 10):
|
||||
t = T0 + i * MIN
|
||||
plan = arbitrate([a, b], t)
|
||||
plan0 = arbitrate([a_ok, b_alone], t)
|
||||
same = same and plan[1] == plan0[1]
|
||||
ra = a.tick(t, None, blocked_by=plan[0])
|
||||
rb = b.tick(t, 55.0, blocked_by=plan[1])
|
||||
a_ok.tick(t, 60.0, blocked_by=plan0[0])
|
||||
rb0 = b_alone.tick(t, 55.0, blocked_by=plan0[1])
|
||||
same = same and (rb.phase, rb.setpoint_w, rb.deferred) == \
|
||||
(rb0.phase, rb0.setpoint_w, rb0.deferred)
|
||||
check("A drains with no SoC at 0 W while B (SoC 55, idle) is as it is when A "
|
||||
"is healthy", ra.setpoint_w == 0.0 and ra.owns_setpoint and rb.phase == IDLE
|
||||
and rb.setpoint_w is None and not rb.owns_setpoint)
|
||||
check("...B's answers are unchanged tick by tick", same)
|
||||
res = None
|
||||
for i in range(0, DRAIN_TIMEOUT_MIN + 30, 10):
|
||||
t = T0 + 120 * MIN + i * MIN
|
||||
plan = arbitrate([a, b], t)
|
||||
res = a.tick(t, None, blocked_by=plan[0])
|
||||
b.tick(t, 55.0, blocked_by=plan[1])
|
||||
if res.failed:
|
||||
break
|
||||
check("A's drain times out and A backs off (A's keys only)",
|
||||
res.failed == "drain" and a.store.get_time("last_failed") is not None
|
||||
and b.store.get_time("last_failed") is None)
|
||||
slot = (T0 + timedelta(days=1)).replace(hour=19, minute=5)
|
||||
check("...then B, with its SoC, takes the slot as usual",
|
||||
arbitrate([a, b], slot) == ["", ""] and b.wants_start(slot)
|
||||
and not a.wants_start(slot))
|
||||
b.force_start(slot)
|
||||
rb = b.tick(slot + 5 * MIN, 50.0)
|
||||
check("...and B's drain runs at the drain rate",
|
||||
rb.phase == DRAIN and rb.setpoint_w == CFG.discharge_w)
|
||||
# the other way: B charges with no SoC, A has a SoC
|
||||
a = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
|
||||
b = Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b")
|
||||
b.force_start(T0)
|
||||
b.tick(T0, 11.0)
|
||||
run(b, T0, 5, 97.0)
|
||||
a_alone = Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a")
|
||||
same, t = True, T0 + 10 * MIN
|
||||
while t < T0 + timedelta(minutes=CHARGE_TIMEOUT_MIN + 30):
|
||||
plan = arbitrate([a, b], t)
|
||||
rb = b.tick(t, None, blocked_by=plan[1])
|
||||
ra = a.tick(t, 60.0, blocked_by=plan[0])
|
||||
ra0 = a_alone.tick(t, 60.0, blocked_by=plan[0])
|
||||
same = same and (ra.phase, ra.setpoint_w, ra.deferred) == \
|
||||
(ra0.phase, ra0.setpoint_w, ra0.deferred)
|
||||
if rb.phase != CHARGE:
|
||||
break
|
||||
t += 5 * MIN
|
||||
check("B charges with no SoC (last 97): A (SoC 60) is unchanged tick by tick",
|
||||
same)
|
||||
check("...B ends as done (HOLD), A untouched, no failure on either",
|
||||
rb.phase == HOLD and rb.failed == ""
|
||||
and b.store.get_time("last_failed") is None
|
||||
and a.store.get_time("last_failed") is None and a.phase == IDLE)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all passed")
|
||||
@@ -122,7 +122,8 @@ m = Maintenance(cfg, FakeStore())
|
||||
m.force_start(t0)
|
||||
r = m.tick(t0 + timedelta(minutes=5), soc=None)
|
||||
check("no SoC: holds the phase rather than guessing", r.phase == DRAIN)
|
||||
check("no SoC: still commands the drain rate", r.setpoint_w == 2500)
|
||||
check("no SoC: MAINT-14 the drain holds at 0 W, never discharges",
|
||||
r.owns_setpoint and r.setpoint_w == 0.0)
|
||||
|
||||
m = Maintenance(cfg, FakeStore())
|
||||
m.store.set("phase", "banana")
|
||||
@@ -622,6 +623,8 @@ def flat_store(**over):
|
||||
"phase_started": "2026-09-03T22:00:00+00:00",
|
||||
"last_completed": "2026-08-07T12:00:00+00:00",
|
||||
"last_start_attempt": "2026-09-03T10:00:00+00:00",
|
||||
# MAINT-13: a failed cycle on record, so that key's move is graded too.
|
||||
"last_failed": "2026-09-01T10:00:00+00:00",
|
||||
}, **over))
|
||||
|
||||
|
||||
@@ -929,10 +932,11 @@ print(f" ok={_rep8.ok} lost={len(_rep8.lost)} kept={len(_rep8.kept)} "
|
||||
f"misdirected={len(_rep8.misdirected)}; marker "
|
||||
f"{_m8.data.get(MAINT_SCHEMA_KEY, '<<absent>>')!r}")
|
||||
check("PRECONDITION: this fixture reaches the marker through the `lost` guard "
|
||||
"and ONLY that one - two keys in `kept`, two in `lost`, `misdirected` "
|
||||
"and ONLY that one - two keys in `kept`, three in `lost` (the three the "
|
||||
"fixture records; MAINT-13 added `last_failed`), `misdirected` "
|
||||
"empty. If it ever stops having a non-empty `kept` the mutation below "
|
||||
"goes invisible again, so the shape is asserted rather than assumed",
|
||||
_rep8.ran and len(_rep8.kept) == 2 and len(_rep8.lost) == 2
|
||||
_rep8.ran and len(_rep8.kept) == 2 and len(_rep8.lost) == 3
|
||||
and not _rep8.misdirected and not _rep8.ok)
|
||||
check("⚠️ THE MARKER IS NOT STAMPED ON A MIGRATION THAT LOST A MONTH OF "
|
||||
"HISTORY, and the two keys that DID land do not buy it one. `rep.ok` is "
|
||||
@@ -1010,10 +1014,14 @@ check("...and nothing about a deferral, a slot or another pack appears in any "
|
||||
# pressure.
|
||||
_solo2 = Maintenance(cfg, MemStore())
|
||||
_solo2.force_start(t0)
|
||||
# MAINT-13: a drain that times out is a failed cycle, so one plain line follows
|
||||
# the abort line (the abort line itself is unchanged).
|
||||
check("...and so is the abort, which is the string an operator reads under "
|
||||
"pressure",
|
||||
_solo2.tick(t0 + timedelta(hours=13), 60.0).events
|
||||
== ["maintenance: ABORT (drain stuck at 60 % after 780 min)"])
|
||||
== ["maintenance: ABORT (drain stuck at 60 % after 780 min)",
|
||||
"maintenance: the cycle did not finish. It waits 7 days before it "
|
||||
"tries again."])
|
||||
|
||||
|
||||
|
||||
|
||||
@@ -0,0 +1,401 @@
|
||||
"""Runnable check for SAFETY-103: no swing on old battery readings after a
|
||||
drain ends. `python3 test_safety103.py`
|
||||
|
||||
While a battery settles from its ended drain (SAFETY-95), the loop works
|
||||
from the grid plus each battery's reading. A reading can be one register
|
||||
period (10 s) older than the meter: on the rig (SAFETY-95 test, check 5) A's
|
||||
reading still said 1238 W while A was at 616 W, and B went 860 -> 1650 ->
|
||||
870 W. Now the house point is held, and moved only as far as the meter
|
||||
proves (each battery between its last changed reading and its commands
|
||||
since). Drives the REAL Controller on tools/safety103_plant.py: a lagging
|
||||
battery, the meter every 1 s, registers every 10 s at the rig's phases, B
|
||||
idling at -100 W. DECISIONS/SAFETY-103-old-readings-after-a-drain.md.
|
||||
|
||||
1. The rig case and every drain end at N=2 and N=3, 10 s registers: no
|
||||
swing beyond one slew step; release/1.0 swings (non-vacuous).
|
||||
2. SAFETY-95/96's gains stay: no jump at the end, no give into a surplus,
|
||||
one slew step a cycle, refusal and stale link still learned.
|
||||
3. A house step inside the window is still followed.
|
||||
4. With readings as fresh as the meter, every row is release/1.0's; N=1 is
|
||||
untouched.
|
||||
5. The rule's parts, one by one.
|
||||
|
||||
Mutations (MUTATION.md, purged copies) are listed in the pull request.
|
||||
"""
|
||||
|
||||
import hashlib
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import sys
|
||||
|
||||
HERE = os.path.dirname(os.path.abspath(__file__))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
logging.disable(logging.WARNING)
|
||||
|
||||
import safety103_plant as p # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import DRAIN # noqa: E402
|
||||
|
||||
fails = []
|
||||
SLEW = 400.0 # the rig's slew_w
|
||||
AIM = -10.0 # the rig's target_grid_w
|
||||
T = p.T
|
||||
A = p.A
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
fixed = Controller._drain_grid_w
|
||||
track = getattr(Controller, "_track_reads", None)
|
||||
|
||||
|
||||
def _release(self, live):
|
||||
"""release/1.0's `_drain_grid_w` (SAFETY-95 as merged): every battery at
|
||||
its reading."""
|
||||
grid = float(self.grid)
|
||||
self._drain_tail &= set(self._settle) & set(live)
|
||||
if not self._drain_tail:
|
||||
return grid
|
||||
return grid - float(self.target) + sum(
|
||||
float(inv.batt) for inv in self.inverters if inv.name in live)
|
||||
|
||||
|
||||
def without(fn):
|
||||
"""Run `fn` with SAFETY-103 taken out (release/1.0's rule)."""
|
||||
Controller._drain_grid_w = _release
|
||||
try:
|
||||
return fn()
|
||||
finally:
|
||||
Controller._drain_grid_w = fixed
|
||||
|
||||
|
||||
def soc_done(u, t):
|
||||
return 5.0 if (u == "a" and t >= T) else 50.0
|
||||
|
||||
|
||||
# A's drain ends at T: switched Off (the rig case), completed on SoC, its
|
||||
# battery refusing (gives nothing from T; SAFETY-73 learns it later), or its
|
||||
# link going stale (writes refused from T, its board to 0 W 25 s later).
|
||||
ENDS = {
|
||||
"Off": dict(),
|
||||
"complete": dict(before=None, soc=soc_done),
|
||||
"refusal": dict(before=None, dead=("a", T), dur=T + 150.0),
|
||||
"stale link": dict(before=None, reject={"a": T}, dead=("a", T + 25.0),
|
||||
dur=T + 150.0),
|
||||
}
|
||||
|
||||
|
||||
def end_of(rows):
|
||||
"""The first cycle A's drain is over (its command left 2000 W, or its
|
||||
phase left DRAIN); None if never."""
|
||||
return next((r["t"] for r in rows if r["t"] >= T and (
|
||||
r["cmd"][0] < 1990.0 or r["phase"][0] != DRAIN)), None)
|
||||
|
||||
|
||||
def measure(rows, n, house):
|
||||
"""From the end on: the largest swing of the others' summed command in
|
||||
the 23 s window (a move later undone; the slew step is the site's); their
|
||||
largest command on the end cycle; the site target's largest step after
|
||||
the end cycle; the others' largest command after the end (for a
|
||||
surplus); the grid's range in the window."""
|
||||
te = end_of(rows)
|
||||
if te is None:
|
||||
return dict(end=math.nan, swing=math.nan, first=math.nan,
|
||||
step=math.nan, give=math.nan, gmin=math.nan,
|
||||
gmax=math.nan, rows=rows)
|
||||
win = [r for r in rows if te <= r["t"] <= te + 23.0]
|
||||
sw = 0.0
|
||||
w = [sum(r["cmd"][1:]) for r in win][1:]
|
||||
for j in range(len(w)):
|
||||
sw = max(sw, min(w[j] - min(w[:j + 1]), w[j] - min(w[j:])),
|
||||
min(max(w[:j + 1]) - w[j], max(w[j:]) - w[j]))
|
||||
seg = [r["target"] for r in rows if r["t"] >= te]
|
||||
return dict(
|
||||
end=te, swing=sw,
|
||||
first=max(win[0]["cmd"][1:]) if win else math.nan,
|
||||
step=max(abs(b - a) for a, b in zip(seg, seg[1:])),
|
||||
give=max(max(r["cmd"][1:]) for r in rows if r["t"] >= te),
|
||||
gmin=min(r["grid"] for r in win), gmax=max(r["grid"] for r in win),
|
||||
rows=rows)
|
||||
|
||||
|
||||
def run(kind, n, house, **k):
|
||||
return p.run(n, house, **dict(ENDS[kind], **k))[0]
|
||||
|
||||
|
||||
TABLE = []
|
||||
# A settles from its drain: the tail this rule is about. A refusing battery
|
||||
# already reads ~0 W, and a dropped one is out of the split (the meter has
|
||||
# it), so their tails last at most a cycle.
|
||||
SETTLE = ("Off", "complete")
|
||||
|
||||
|
||||
def case(kind, n, house, **k):
|
||||
now = measure(run(kind, n, house, **k), n, house)
|
||||
old = measure(without(lambda: run(kind, n, house, **k)), n, house)
|
||||
fresh = measure(run(kind, n, house, reg_s=1.0, **k), n, house)
|
||||
TABLE.append((kind, n, house, now, old, fresh))
|
||||
return now, old, fresh
|
||||
|
||||
|
||||
# ============================================================================ #
|
||||
print("1. no swing on an old reading: every drain end, N=2 and N=3, 10 s "
|
||||
"registers")
|
||||
for kind in ENDS:
|
||||
for n in (2, 3):
|
||||
for house in (1200.0, 4000.0, -1500.0):
|
||||
now, old, fresh = case(kind, n, house)
|
||||
own = kind in SETTLE
|
||||
check(f"{'⭐' if kind == 'Off' else ' '} {kind}, N={n}, house "
|
||||
f"{house:.0f} W: old readings add at most one slew step "
|
||||
f"to the others' swing in the 23 s after the end"
|
||||
f"{', and it is at most one slew step' if own else ''} "
|
||||
f"({now['swing']:.0f} W; 1 s registers "
|
||||
f"{fresh['swing']:.0f}; release/1.0 {old['swing']:.0f})",
|
||||
now["swing"] - fresh["swing"] <= SLEW
|
||||
and (not own or now["swing"] <= SLEW))
|
||||
_by = {(k, n, h): (a, b) for k, n, h, a, b, f in TABLE}
|
||||
_now, _old = _by[("Off", 2, 1200.0)]
|
||||
_b = [r["cmd"][1] for r in _now["rows"] if 0 <= r["t"] - _now["end"] <= 23]
|
||||
_bo = [r["cmd"][1] for r in _old["rows"] if 0 <= r["t"] - _old["end"] <= 23]
|
||||
print(f" rig check 5 (N=2, 1200 W, A Off): B {_b}\n"
|
||||
f" release/1.0: B {_bo}")
|
||||
check("⭐ the rig case (SAFETY-95 check 5): release/1.0 swings B by more "
|
||||
"than a slew step on A's old reading; now B holds within 50 W",
|
||||
_old["swing"] > SLEW and max(_b) - min(_b) <= 50.0)
|
||||
for n in (2, 3):
|
||||
check(f"non-vacuous (N={n}): on release/1.0 old readings add more than "
|
||||
f"a slew step in at least one of these cases",
|
||||
any(b["swing"] - f["swing"] > SLEW
|
||||
for k, nn, h, a, b, f in TABLE if nn == n))
|
||||
_s5 = []
|
||||
for lag in (5.0, 20.0):
|
||||
for reg in (5.0, 10.0):
|
||||
for n in (2, 3):
|
||||
_s5.append(measure(run("Off", n, 1200.0, lag=lag, reg_s=reg), n,
|
||||
1200.0)["swing"])
|
||||
check(f"no plant constant is assumed: battery lag 5 s and 20 s, registers "
|
||||
f"every 5 s and 10 s, N=2 and N=3: largest swing {max(_s5):.0f} W",
|
||||
max(_s5) <= SLEW)
|
||||
_ph = [measure(run("Off", 2, 1200.0, phase={"a": a, "b": b}), 2, 1200.0)
|
||||
["swing"] for a, b in ((0.0, 0.5), (0.9, 0.1), (0.3, 0.3))]
|
||||
check(f"other register phases: largest swing {max(_ph):.0f} W",
|
||||
max(_ph) <= SLEW)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n2. SAFETY-95/96's gains stay")
|
||||
for kind in ENDS:
|
||||
for n in (2, 3):
|
||||
now, old = _by[(kind, n, 1200.0)]
|
||||
check(f"{kind}, N={n}, 1200 W: no jump on the end cycle (others "
|
||||
f"<= the house, {now['first']:.0f} W) and the site moves at "
|
||||
f"most one slew step a cycle after ({now['step']:.0f} W)",
|
||||
now["first"] <= 1200.0 - AIM + 50.0 and now["step"] <= SLEW)
|
||||
now, old = _by[(kind, n, -1500.0)]
|
||||
check(f"{kind}, N={n}, solar surplus: no battery gives into it "
|
||||
f"(largest command after the end {now['give']:.0f} W"
|
||||
+ (f"; a lost link as release/1.0, {old['give']:.0f} W)"
|
||||
if kind == "stale link" else ")"),
|
||||
now["give"] <= (max(50.0, old["give"]) if kind == "stale link"
|
||||
else 50.0))
|
||||
_now, _old = _by[("Off", 2, 1200.0)]
|
||||
check(f"the grid in the window stays inside release/1.0's range "
|
||||
f"([{_now['gmin']:.0f}, {_now['gmax']:.0f}] W, release/1.0 "
|
||||
f"[{_old['gmin']:.0f}, {_old['gmax']:.0f}])",
|
||||
_now["gmin"] >= _old["gmin"] - 50.0 and _now["gmax"] <= _old["gmax"])
|
||||
|
||||
|
||||
_ref = {}
|
||||
for name, f in (("now", lambda: p.run(2, 1200.0, **ENDS["refusal"])),
|
||||
("old", lambda: without(lambda: p.run(
|
||||
2, 1200.0, **ENDS["refusal"])))):
|
||||
rows, c = f()
|
||||
_ref[name] = (c.inverters[0].refused, c.inverters[0].refused_at)
|
||||
check(f"a refusal is still learned, at the same instant as release/1.0 "
|
||||
f"({_ref['now']})", _ref["now"] == _ref["old"]
|
||||
and _ref["now"][0] == 1)
|
||||
_st = {}
|
||||
for name, f in (("now", lambda: p.run(2, 1200.0, **ENDS["stale link"])),
|
||||
("old", lambda: without(lambda: p.run(
|
||||
2, 1200.0, **ENDS["stale link"])))):
|
||||
rows, c = f()
|
||||
_st[name] = sorted(c.live_units())
|
||||
check(f"a stale link is still dropped, as in release/1.0 "
|
||||
f"(live: {_st['now']})", _st["now"] == _st["old"]
|
||||
and len(_st["now"]) == 1)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n3. a house step inside the window is still followed")
|
||||
|
||||
|
||||
def step(sign):
|
||||
return lambda t: 1200.0 + (sign * 2000.0 if t >= T + 5.0 else 0.0)
|
||||
|
||||
|
||||
for sign, what in ((1, "kettle +2000 W"), (-1, "solar -2000 W")):
|
||||
for n in (2, 3):
|
||||
rows = p.run(n, step(sign))[0]
|
||||
rows_o = without(lambda: p.run(n, step(sign)))[0]
|
||||
te = end_of(rows)
|
||||
|
||||
def wh(rs):
|
||||
return sum(abs(r["grid"] - AIM) for r in rs
|
||||
if te + 5.0 <= r["t"] <= te + 35.0) / 3600.0
|
||||
sw = measure(rows, n, 1200.0)["swing"]
|
||||
check(f"{what} at E+5 s, N={n}: the grid's distance from its aim "
|
||||
f"over the next 30 s is within 1.5 Wh of release/1.0's "
|
||||
f"({wh(rows):.1f} Wh, release/1.0 {wh(rows_o):.1f}); swing "
|
||||
f"{sw:.0f} W", wh(rows) <= wh(rows_o) + 1.5 and sw <= SLEW)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. fresh readings and N=1: release/1.0's rows")
|
||||
|
||||
|
||||
def digest(rows):
|
||||
return hashlib.sha256(repr(rows).encode()).hexdigest()
|
||||
|
||||
|
||||
_fresh = [(n, h) for n in (2, 3) for h in (1200.0, 4000.0, -1500.0)]
|
||||
check("⭐ registers as fresh as the meter (1 s), N=2 and N=3, three houses: "
|
||||
"every row byte-identical with release/1.0 (a reading that changed "
|
||||
"this cycle is taken as it is)",
|
||||
[digest(p.run(n, h, reg_s=1.0)[0]) for n, h in _fresh]
|
||||
== [digest(without(lambda: p.run(n, h, reg_s=1.0))[0])
|
||||
for n, h in _fresh])
|
||||
_rf = [(n, h) for n in (2, 3) for h in (1200.0, -1500.0)]
|
||||
check("⭐ a refusal end, 10 s registers, N=2 and N=3, 1200 W and a surplus: "
|
||||
"every row byte-identical with release/1.0 (A reads ~0 W and will not "
|
||||
"give, so its side is its reading)",
|
||||
[digest(run("refusal", n, h)) for n, h in _rf]
|
||||
== [digest(without(lambda: run("refusal", n, h))) for n, h in _rf])
|
||||
_n1 = [dict(), dict(before=None, soc=soc_done)]
|
||||
check("⭐ N=1, A switched Off and A's drain completing, 10 s registers: "
|
||||
"every row byte-identical with release/1.0",
|
||||
[digest(p.run(1, 1200.0, **k)[0]) for k in _n1]
|
||||
== [digest(without(lambda: p.run(1, 1200.0, **k))[0]) for k in _n1])
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n5. the rule's parts")
|
||||
_c = p.run(2, 1200.0, dur=4.0)[1]
|
||||
AB = {"inverter-a", "inverter-b"}
|
||||
ia, ib = _c.inverters
|
||||
|
||||
|
||||
def at(now, batts, cmds, changed):
|
||||
"""Set the clock, each battery's reading, its standing command and the
|
||||
instant its reading last changed; then track."""
|
||||
_c._now_mono = now
|
||||
for inv, b, cmd, ch in zip(_c.inverters, batts, cmds, changed):
|
||||
inv.batt, inv.last_write = b, cmd
|
||||
inv.batt_fresh.changed_mono = ch
|
||||
_c._track_reads()
|
||||
|
||||
|
||||
_c._read_span = {}
|
||||
at(10.0, (2000.0, -100.0), (2000.0, 0.0), (10.0, 10.0))
|
||||
check("a reading that changed is the start of its range: (R, R) joined "
|
||||
"with the command on its wire",
|
||||
_c._read_span[A] == (2000.0, 2000.0, 10.0)
|
||||
and _c._read_span["inverter-b"] == (-100.0, 0.0, 10.0))
|
||||
at(11.0, (2000.0, -100.0), (0.0, 1140.0), (10.0, 10.0))
|
||||
at(12.0, (2000.0, -100.0), (0.0, 800.0), (10.0, 10.0))
|
||||
check("every command since the reading widens the range (a lagging "
|
||||
"battery moves toward each in turn): A [0, 2000], B [-100, 1140]",
|
||||
_c._read_span[A][:2] == (0.0, 2000.0)
|
||||
and _c._read_span["inverter-b"][:2] == (-100.0, 1140.0))
|
||||
at(13.0, (1241.0, -100.0), (0.0, 800.0), (13.0, 10.0))
|
||||
check("a new reading starts the range again: A [0, 1241]",
|
||||
_c._read_span[A][:2] == (0.0, 1241.0))
|
||||
_c._read_span = {}
|
||||
_c.inverters = _c.inverters[:1]
|
||||
at(14.0, (2000.0,), (2000.0,), (14.0,))
|
||||
_c.inverters = [ia, ib]
|
||||
check("N=1: nothing is tracked", _c._read_span == {})
|
||||
|
||||
|
||||
def tail(now, grid, target, held=None, live=AB):
|
||||
"""`_drain_grid_w` with A settling: the error it hands the loop (grid
|
||||
minus aim) and the house point it holds."""
|
||||
_c._now_mono, _c.grid, _c.target = now, grid, target
|
||||
_c._drain_tail, _c._settle = {A}, {A: 0.0}
|
||||
_c._drain_house = held
|
||||
g = _c._drain_grid_w(live)
|
||||
return round(g - AIM, 6), _c._drain_house
|
||||
|
||||
|
||||
# A: reading 1241 W from 13 s, range [0, 1241]; B: reading -100 W from 10 s,
|
||||
# range [-100, 1140]. Grid -330 W: the house is in
|
||||
# [-330 + 10 + 0 - 100, -330 + 10 + 1241 + 1140] = [-420, 2061].
|
||||
_c._read_span = {A: (0.0, 1241.0, 13.0), "inverter-b": (-100.0, 1140.0, 10.0)}
|
||||
ia.batt, ib.batt = 1241.0, -100.0
|
||||
ia.batt_fresh.changed_mono, ib.batt_fresh.changed_mono = 13.0, 10.0
|
||||
check("⭐ held: the first window cycle holds the loop's start (1140 W) while "
|
||||
"the meter allows it (error 0; release/1.0's would be -330 + 1241 - "
|
||||
"100 + 10 - 1140 = -319 W)", tail(14.0, -330.0, 1140.0) == (0.0, 1140.0)
|
||||
and round(_release(_c, AB) - AIM) == -319)
|
||||
check("⭐ held, then kept: a later cycle keeps the held point, not the "
|
||||
"loop's target", tail(15.0, -330.0, 1000.0, held=1140.0)
|
||||
== (140.0, 1140.0))
|
||||
check("⭐ moved as far as the meter proves: a grid of +2000 W puts the "
|
||||
"house at least at 2000 + 10 + 0 - 100 = 1910 W",
|
||||
tail(15.0, 2000.0, 1140.0, held=1140.0) == (770.0, 1910.0))
|
||||
check("...and down: a grid of -2500 W puts it at most at -2500 + 10 + 1241 "
|
||||
"+ 1140 = -109 W", tail(15.0, -2500.0, 1140.0, held=1140.0)
|
||||
== (-1249.0, -109.0))
|
||||
ia.batt_fresh.changed_mono = 15.0
|
||||
check("⭐ a reading that changed this cycle is taken as it is: A at 1241 W, "
|
||||
"not [0, 1241], so a grid of +2000 W puts the house at least at "
|
||||
"2000 + 10 + 1241 - 100 = 3151 W", tail(15.0, 2000.0, 1140.0,
|
||||
held=1140.0) == (2011.0, 3151.0))
|
||||
ia.batt_fresh.changed_mono = 13.0
|
||||
# A refuses to give (SAFETY-73): it reads 8 W, though it was asked 2000 W
|
||||
# since that reading. Grid -1500 W: the house is at most -1500 + 10 + 8 +
|
||||
# 1140 = -342 W, not -1500 + 10 + 2000 + 1140 = 1650 W.
|
||||
_c._read_span[A] = (8.0, 2000.0, 13.0)
|
||||
ia.batt = 8.0
|
||||
ia.refused = 1
|
||||
_ref1 = tail(15.0, -1500.0, 1140.0, held=1140.0)
|
||||
ia.refused = -1
|
||||
_c._read_span[A] = (-2000.0, 8.0, 13.0)
|
||||
_ref2 = tail(15.0, 1000.0, -500.0, held=-500.0)
|
||||
ia.refused = 0
|
||||
check("⭐ a battery that refuses one way is taken at its reading on that "
|
||||
"side: will not give, asked 2000 W, reads 8 W -> the house at most "
|
||||
"-342 W; will not take, asked -2000 W -> at least 1000 + 10 + 8 - 100 "
|
||||
"= 918 W", _ref1 == (-1482.0, -342.0) and _ref2 == (1418.0, 918.0))
|
||||
_c._read_span[A], ia.batt = (0.0, 1241.0, 10.0), 1241.0
|
||||
check("a range from an older reading than the one in hand (a cycle the "
|
||||
"loop did not run) is not used: A at its reading, 1241 W",
|
||||
tail(15.0, 2000.0, 1140.0, held=1140.0) == (2011.0, 3151.0))
|
||||
_c._read_span[A] = (0.0, 1241.0, 13.0)
|
||||
check("⭐ a battery out of the split is not counted (the meter has its "
|
||||
"power): B dropped, a grid of +2000 W puts the house at least at "
|
||||
"2000 + 10 + 0 = 2010 W, not 1910 W",
|
||||
tail(15.0, 2000.0, 1140.0, held=1140.0, live={A}) == (870.0, 2010.0))
|
||||
_c._drain_tail, _c._settle, _c._drain_house = {A}, {}, 1140.0
|
||||
_c.grid = -330.0
|
||||
check("⭐ the tail's end lets the hold go: the meter again, and the next "
|
||||
"tail starts from the loop's start",
|
||||
_c._drain_grid_w(AB) == -330.0 and _c._drain_house is None)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n drain end | N | house W | swing W now/release/1 s registers | "
|
||||
"end-cycle others W now/release | site step W now/release | grid in "
|
||||
"window W now | release")
|
||||
for k, n, h, a, b, f in TABLE:
|
||||
print(f" {k} | {n} | {h:.0f} | {a['swing']:.0f}/{b['swing']:.0f}/"
|
||||
f"{f['swing']:.0f} | "
|
||||
f"{a['first']:.0f}/{b['first']:.0f} | {a['step']:.0f}/"
|
||||
f"{b['step']:.0f} | [{a['gmin']:.0f}, {a['gmax']:.0f}] | "
|
||||
f"[{b['gmin']:.0f}, {b['gmax']:.0f}]")
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
sys.exit(1)
|
||||
print("all SAFETY-103 checks passed")
|
||||
@@ -37,7 +37,7 @@ import safety79_identity as s79 # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
from app import packmode # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import (CHARGE_TIMEOUT_MIN, HOLD, IDLE, # noqa: E402
|
||||
from app.maintenance import (CHARGE_TIMEOUT_MIN, DRAIN, HOLD, IDLE, # noqa: E402
|
||||
MaintResult)
|
||||
from app.store import unit_key # noqa: E402
|
||||
from named_absence import first, present # noqa: E402
|
||||
@@ -221,9 +221,16 @@ def switch_off(at):
|
||||
return before
|
||||
|
||||
|
||||
def timed_out_b_done(end):
|
||||
"""timed_out(), with B's monthly cycle finished so it starts none."""
|
||||
s = timed_out(end)
|
||||
s.data[unit_key("inverter-b", "last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
ENDS = {
|
||||
"timeout": lambda: run(2, 6000.0, 9999.0, step=1760.0, dur=2080.0,
|
||||
store=timed_out(1780.0)),
|
||||
store=timed_out_b_done(1780.0)),
|
||||
"Off": lambda: run(2, 6000.0, 9999.0, step=1760.0, dur=2080.0,
|
||||
store=b_done(), before=switch_off(1780.0),
|
||||
extra={"battery_modes_enabled": True}),
|
||||
@@ -246,6 +253,31 @@ for k, fn in ENDS.items():
|
||||
f"the grid", at(old, 1780.0, "b") == -1600.0
|
||||
and charging_hi(old, 1780, 1798, hi1) >= 1)
|
||||
|
||||
# MAINT-13: A's timed-out charge is a failed cycle and backs off, so A no longer
|
||||
# restarts at once; a due B takes the slot instead and starts ITS drain. That is
|
||||
# a drain start (a step to the drain rate by design), not a charge end.
|
||||
rows, c = run(2, 6000.0, 9999.0, step=1760.0, dur=2080.0,
|
||||
store=timed_out(1780.0))
|
||||
print(f" timeout, B due: A {[cmd(r)['a'] for r in rows if 1776 <= r[0] <= 1790]}"
|
||||
f" B {[cmd(r)['b'] for r in rows if 1776 <= r[0] <= 1790]}")
|
||||
check("timeout with B due: the charge ends at 1780 s and A is not restarted",
|
||||
phase_at(rows, 1778.0) == "charge" and phase_at(rows, 1780.0) == IDLE
|
||||
and c.maints[0].phase == IDLE
|
||||
and c.maints[0].backoff_until(rig.BASE + timedelta(seconds=1800))
|
||||
is not None)
|
||||
# A command below 0 W is a charge, so B's commands must stay at or above 0;
|
||||
# the drain rate is the one this rig's controller was configured with.
|
||||
drain_w = c.maints[1].cfg.discharge_w
|
||||
print(f" B drain rate configured on the rig: {drain_w:.0f} W")
|
||||
check("⭐ timeout with B due: no battery charges from the grid after it",
|
||||
charging_hi(rows, 1780, 1798, hi1) == 0
|
||||
and min(cmd(r)["b"] for r in rows if r[0] >= 1780) >= 0.0)
|
||||
check("...B takes the slot and begins its own drain, which is the only large "
|
||||
"step, to the configured drain rate and no higher",
|
||||
c.maints[1].phase == DRAIN
|
||||
and max(cmd(r)["b"] for r in rows if r[0] >= 1780) <= drain_w
|
||||
and moves(rows, "a", 1780, 1798) <= SLEW)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n4. the charge ends while the guard has suspended it")
|
||||
# House 6000 W from 1500 s: the guard suspends the shaping, the loop has both
|
||||
|
||||
@@ -0,0 +1,195 @@
|
||||
"""SAFETY-103's plant: test_safety95's lagging battery with the SAFETY-90
|
||||
register model, driven through the REAL Controller in simulated time.
|
||||
|
||||
Each battery ramps at 800 W/s, then follows a first-order lag (`lag` s). Its
|
||||
power register publishes every `reg_s` s at its own phase (the SAFETY-90/96
|
||||
rig: A at 0.6, B at 0.16 of the period), and reads `off` W from the truth
|
||||
(B idles at -100 W). The meter reads every cycle (`tick` s). A drain on A
|
||||
runs from the first cycle (the others finished theirs); `before(c, t)` ends
|
||||
it. `run()` has no side effects on import, so tests and probes share it.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import math
|
||||
import os
|
||||
import random
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import timedelta
|
||||
|
||||
HERE = os.path.dirname(os.path.dirname(os.path.abspath(__file__)))
|
||||
sys.path.insert(0, HERE)
|
||||
sys.path.insert(0, os.path.join(HERE, "tools"))
|
||||
|
||||
import opt11_identity as rig # noqa: E402
|
||||
from app import main as app_main, packmode # noqa: E402
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
|
||||
A = "inverter-a"
|
||||
T = 300.0 # A's drain ends here
|
||||
PHASE = {"a": 0.6, "b": 0.16, "c": 0.38}
|
||||
OFF = {"b": -100.0} # the rig's B: idle reading -100 W
|
||||
M = {"maintenance_enabled": True, "maintenance_start_hour": 11,
|
||||
"battery_modes_enabled": True}
|
||||
|
||||
|
||||
def options(n, extra=None):
|
||||
o = rig._options(n, dict(M, **(extra or {})))
|
||||
if n > 1:
|
||||
o["inverters"] = [
|
||||
{"name": f"inverter-{u}", "setpoint_entity": f"number.sp_{u}",
|
||||
"soc_entity": f"sensor.soc_{u}", "batt_entity": f"sensor.batt_{u}",
|
||||
"max_w": 2500, "bms_soc_floor": 10} for u in "abc"[:n]]
|
||||
return o
|
||||
|
||||
|
||||
def store(n):
|
||||
"""A due for its monthly cycle (it drains from the first cycle)."""
|
||||
s = rig._Store()
|
||||
for u in "bc"[:n - 1]:
|
||||
s.data[unit_key(f"inverter-{u}", "last_completed")] = \
|
||||
rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def off(c, t):
|
||||
"""A switched Off at T (the SAFETY-95 check 5 end)."""
|
||||
if t >= T:
|
||||
c.store.data[unit_key(A, packmode.USE_KEY)] = False
|
||||
|
||||
|
||||
def run(n, house, *, before=off, dur=T + 90.0, tick=1.0, reg_s=10.0,
|
||||
lag=10.0, noise=50.0, seed=103, phase=None, offs=None, extra=None,
|
||||
st=None, soc=None, dead=None, reject=None):
|
||||
"""Rows of one run. Each row is a dict: t, cmd (the add-on's commands),
|
||||
target, grid (true), true (each battery's power), read (each register),
|
||||
age (s since each register published), phase (maintenance phases).
|
||||
`dead` (u, from s): u gives nothing from then on (board at 0 W).
|
||||
`reject` {u: from s}: writes to u are refused from then on."""
|
||||
units = tuple("abc"[:n])
|
||||
phase = PHASE if phase is None else phase
|
||||
offs = OFF if offs is None else offs
|
||||
rnd = random.Random(seed)
|
||||
soc = soc or (lambda u, t: 50.0)
|
||||
|
||||
class Hass(rig._Hass):
|
||||
def __init__(self, *a):
|
||||
super().__init__(*a)
|
||||
self.tgt = {u: 0.0 for u in units}
|
||||
self.act = {u: 0.0 for u in units}
|
||||
self.reg = {u: 0.0 for u in units}
|
||||
self.pub_t = {u: 0.0 for u in units}
|
||||
self.slot = {u: None for u in units}
|
||||
self.tl = 0.0
|
||||
self.hn = 0.0
|
||||
|
||||
def advance(self, t):
|
||||
for k in range(int(round((t - self.tl) / 0.1))):
|
||||
now = self.tl + (k + 1) * 0.1
|
||||
for u in units:
|
||||
c = self.cmd[u]
|
||||
if dead is not None and u == dead[0] and now >= dead[1]:
|
||||
c = 0.0
|
||||
d = c - self.tgt[u]
|
||||
self.tgt[u] += math.copysign(min(abs(d), 80.0), d)
|
||||
self.act[u] += (self.tgt[u] - self.act[u]) * (
|
||||
1 - math.exp(-0.1 / lag))
|
||||
s = math.floor((now - phase.get(u, 0.0) * reg_s) / reg_s)
|
||||
if s != self.slot[u]:
|
||||
self.slot[u] = s
|
||||
self.reg[u] = float(round(self.act[u] + offs.get(u, 0.0)))
|
||||
self.pub_t[u] = now
|
||||
self.tl = t
|
||||
self.hn = rnd.uniform(-noise, noise) if noise else 0.0
|
||||
|
||||
def power(self, u):
|
||||
return self.reg[u]
|
||||
|
||||
def grid(self):
|
||||
h = house(self.t) if callable(house) else house
|
||||
return float(round(h + self.hn - sum(self.act.values())))
|
||||
|
||||
async def set_number(self, e, v):
|
||||
u = e[-1]
|
||||
if reject and u in reject and self.t >= reject[u]:
|
||||
return False
|
||||
self.cmd[u] = float(v)
|
||||
return True
|
||||
|
||||
opts = options(n, extra)
|
||||
db = os.path.join(tempfile.mkdtemp(prefix="s103-"), "tariff.db")
|
||||
|
||||
async def go():
|
||||
hass = Hass(units, soc, lambda u, t: False, lambda t: 0.0)
|
||||
c = Controller(opts, hass, st or store(n), rig._Pub(),
|
||||
stop=asyncio.Event(), peak_db_path=db)
|
||||
for i in c.inverters:
|
||||
i.dev_min, i.dev_max = -5000.0, 5000.0
|
||||
c.auto = True
|
||||
real_dt, clock = app_main.datetime, [0.0]
|
||||
|
||||
class _DT(real_dt):
|
||||
@classmethod
|
||||
def now(cls, tz=None):
|
||||
return rig.BASE + timedelta(seconds=clock[0])
|
||||
app_main.datetime = _DT
|
||||
rows = []
|
||||
try:
|
||||
t = 0.0
|
||||
while t < dur:
|
||||
hass.advance(t)
|
||||
hass.t = clock[0] = t
|
||||
for inv in c.inverters:
|
||||
u = inv.name[-1]
|
||||
if reject and u in reject and t >= reject[u] \
|
||||
and inv.rejected_since is None:
|
||||
inv.rejected_since = rig.BASE + timedelta(seconds=t)
|
||||
if before is not None:
|
||||
r = before(c, t)
|
||||
if asyncio.iscoroutine(r):
|
||||
await r
|
||||
await c.read_inputs(now_mono=t)
|
||||
await c.cycle()
|
||||
rows.append(dict(
|
||||
t=t, cmd=tuple(i.target for i in c.inverters),
|
||||
target=c.target, grid=hass.grid(),
|
||||
true=tuple(round(hass.act[u]) for u in units),
|
||||
read=tuple(hass.reg[u] for u in units),
|
||||
age=tuple(round(t - hass.pub_t[u], 1) for u in units),
|
||||
phase=tuple(m.phase for m in c.maints),
|
||||
reason=c.loop_reason))
|
||||
t += tick
|
||||
finally:
|
||||
app_main.datetime = real_dt
|
||||
return rows, c
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
def end_at(rows):
|
||||
"""The first cycle A's command left its drain (None if it never did)."""
|
||||
return next((r["t"] for r in rows if r["t"] >= T
|
||||
and r["cmd"][0] < 1990.0), None)
|
||||
|
||||
|
||||
def window(rows, span=23.0):
|
||||
"""The rows from the end cycle to `span` s after it (the settle window,
|
||||
PLANT_SETTLE_DOWN_S)."""
|
||||
te = end_at(rows)
|
||||
return [r for r in rows if te is not None and te <= r["t"] <= te + span]
|
||||
|
||||
|
||||
def swing(rows, i=1, span=23.0):
|
||||
"""Battery i's command in the settle window after the end cycle, and
|
||||
its largest swing there: a move that is later undone (up then down, or
|
||||
down then up), the smaller of its two legs. A steady climb scores 0."""
|
||||
w = [r["cmd"][i] for r in window(rows, span)][1:]
|
||||
best = 0.0
|
||||
for j in range(len(w)):
|
||||
lo_b = min(w[:j + 1])
|
||||
hi_b = max(w[:j + 1])
|
||||
lo_a = min(w[j:])
|
||||
hi_a = max(w[j:])
|
||||
best = max(best, min(w[j] - lo_b, w[j] - lo_a),
|
||||
min(hi_b - w[j], hi_a - w[j]))
|
||||
return best, w
|
||||