2513ba1f12 |
@@ -8,3 +8,11 @@
|
||||
* text=auto eol=lf
|
||||
*.png binary
|
||||
*.gz binary
|
||||
|
||||
# `.gitea/workflows/*.yml` steps embed shell heredocs; a `\r` on the terminator
|
||||
# line means the heredoc never closes and the job fails on a syntax error that is
|
||||
# invisible in the diff. A Windows checkout with core.autocrlf=true would
|
||||
# reintroduce it on the next edit. CI-01.
|
||||
*.yml text eol=lf
|
||||
*.yaml text eol=lf
|
||||
Dockerfile text eol=lf
|
||||
|
||||
@@ -0,0 +1,22 @@
|
||||
# The image the add-on's tests run in (CI-01). This repo had NO CI at all before
|
||||
# that ticket - eight runnable test files, none of them ever run by a machine.
|
||||
#
|
||||
# ⚠️ THE DEPENDENCIES ARE THE SHIPPED ONES, FROM APK, AND THAT IS THE POINT.
|
||||
# goodwe_controller/Dockerfile installs `py3-aiohttp py3-paho-mqtt` from Alpine
|
||||
# packages rather than pip, because Alpine ships musl and there are no musl
|
||||
# wheels for aiohttp - pip would compile it from source on a client's Raspberry
|
||||
# Pi. Testing against pip-installed glibc wheels would be testing a different
|
||||
# add-on from the one that ships. Same base, same package manager, same names.
|
||||
#
|
||||
# ⚠️ NOT `FROM ghcr.io/home-assistant/...-base`. The real Dockerfile takes its
|
||||
# base from the Supervisor's `BUILD_FROM` build-arg, which is per-architecture
|
||||
# and not resolvable outside a Supervisor build. `alpine:3` is what those images
|
||||
# are, minus the s6 supervision the tests do not use - and it is already cached
|
||||
# on this runner's host, so the gate does not depend on a registry pull.
|
||||
#
|
||||
# ⚠️ The runner container itself CANNOT run these tests: it is Alpine with a bare
|
||||
# python3, no aiohttp, no pip (`No module named pip`; checked on the box, not
|
||||
# assumed). An image is not gold-plating here, it is the only option that does
|
||||
# not mutate a shared long-lived runner.
|
||||
FROM alpine:3
|
||||
RUN apk add --no-cache python3 py3-aiohttp py3-paho-mqtt
|
||||
@@ -0,0 +1,136 @@
|
||||
# CI-01: this repository's FIRST automated check. Before this file, admin/goodwe-addon
|
||||
# had no `.gitea/workflows/` directory at all - eight runnable test files, ~100 s
|
||||
# of real coverage including a wall-clock cadence test, and not one machine ever
|
||||
# ran them. Every merge here was a human reading a diff.
|
||||
#
|
||||
# ⚠️ NO `paths:` FILTER, AND ITS ABSENCE IS LOAD-BEARING. Branch protection on
|
||||
# release/1.0 requires the context `checks / unit (pull_request)`. Gitea leaves a
|
||||
# required context it never receives PENDING forever, so the moment this workflow
|
||||
# learns to sit a PR out, that PR becomes unmergeable. Condition a STEP if you
|
||||
# must; never the workflow.
|
||||
#
|
||||
# ⚠️ THE RUNNER IS SHARED WITH THE OTHER REPO'S RIG. `goodwe-runner` on
|
||||
# 192.168.2.147 carries the labels `self-hosted` and `goodwe-rig` and is
|
||||
# registered `:host`, and it is the only runner there is - so this job wears the
|
||||
# rig label without wanting a rig. Nothing below starts, stops, or reads the
|
||||
# `goodwe-sim` compose project or takes `sim/riglock.py`; it runs one short
|
||||
# container and exits. It does occupy the runner's single slot (`capacity: 1`),
|
||||
# so it QUEUES behind a rig campaign - a delayed verdict, never a destroyed one.
|
||||
#
|
||||
# NO JS ACTIONS: the runner image has no node, so `actions/checkout` cannot run.
|
||||
# Checkout is seven lines of git below.
|
||||
name: checks
|
||||
|
||||
on:
|
||||
pull_request:
|
||||
branches: [release/1.0, master]
|
||||
workflow_dispatch:
|
||||
|
||||
concurrency:
|
||||
# ⚠️ PER PULL REQUEST, NOT A BARE NAME. A shared group holds one running and
|
||||
# one pending run, so a bare name lets a second PR supersede a first PR's run
|
||||
# before any runner has picked it up - which is exactly what happened to the
|
||||
# other repo's run 521 (four jobs, `started_at` at the Unix epoch,
|
||||
# `runner_id: 0`, concluded `cancelled`, and the PR merged anyway). Do not
|
||||
# replace this with a constant.
|
||||
group: addon-checks-${{ github.event.pull_request.number || github.ref }}
|
||||
cancel-in-progress: true
|
||||
|
||||
jobs:
|
||||
unit:
|
||||
runs-on: [self-hosted, goodwe-rig]
|
||||
timeout-minutes: 70 # ~4 to run; the rest is queueing for the single slot
|
||||
env:
|
||||
# ⚠️ UNDER /home/homelab, NOT $GITHUB_WORKSPACE (ENV-01, and re-measured
|
||||
# during CI-01). act's workspace is `/root/.cache/act/<id>/hostexecutor`, a
|
||||
# path that exists only INSIDE the runner container. Hand it to the host's
|
||||
# snap-confined dockerd and the build fails with "failed to read
|
||||
# dockerfile", or - worse, and this is the documented case - a bind mount
|
||||
# resolves to an EMPTY DIRECTORY with no error at all. /home/homelab is
|
||||
# mirrored 1:1 into the runner and is under $HOME, where snap confinement
|
||||
# accepts it. The same probe under /tmp failed and under $HOME succeeded.
|
||||
WS: /home/homelab/ci/addon-checks-${{ github.run_number }}
|
||||
steps:
|
||||
# ⚠️ THE CHECKOUT IS TWO LEVELS BELOW THE MOUNT ROOT, DELIBERATELY.
|
||||
# test_freeze.py's find_hwsim() reads `HERE.parents[1] / "goodwe" / "sim"`,
|
||||
# looking for the infra repo as a SIBLING of this one. Check out flat -
|
||||
# goodwe_controller directly at the mount root - and `parents[1]` does not
|
||||
# exist, so the test dies on `IndexError: 1` before its first assertion.
|
||||
# Measured during CI-01; the flat layout was tried first and did exactly
|
||||
# that. $WS/goodwe-addon/goodwe_controller gives parents[1] == $WS.
|
||||
- name: checkout into a path the host shares (git; no node for actions/checkout)
|
||||
env:
|
||||
URL: ${{ github.server_url }}/${{ github.repository }}.git
|
||||
TOKEN: ${{ secrets.GITHUB_TOKEN }}
|
||||
run: |
|
||||
set -eu
|
||||
rm -rf "$WS" && mkdir -p "$WS/goodwe-addon" && cd "$WS/goodwe-addon"
|
||||
git init -q .
|
||||
git remote add origin "$(echo "$URL" | sed "s#://#://x-access-token:${TOKEN}@#")"
|
||||
git fetch -q --depth 1 origin "$GITHUB_REF" || git fetch -q --depth 1 origin "$GITHUB_SHA"
|
||||
git checkout -qf FETCH_HEAD
|
||||
echo "checked out $(git log --oneline -1)"
|
||||
|
||||
- name: build the test image (shipped deps, from apk - see .gitea/ci/Dockerfile)
|
||||
run: |
|
||||
set -eu
|
||||
docker build -q -t goodwe-addon-checks:1 "$WS/goodwe-addon/.gitea/ci" >/dev/null
|
||||
docker run --rm goodwe-addon-checks:1 python3 -c \
|
||||
'import aiohttp, paho.mqtt.client as m, sys; print("python", sys.version.split()[0], "aiohttp", aiohttp.__version__)'
|
||||
|
||||
# ⚠️ THE FILE LIST IS DERIVED FROM THE TREE, NOT TYPED HERE. A hand-written
|
||||
# list is how a new test file joins the repo and is never run - the exact
|
||||
# shape of failure this ticket exists to close. The step globs `test_*.py`,
|
||||
# prints the count, and REFUSES A COUNT OF ZERO: a loop over an empty glob
|
||||
# exits 0 and would report a green gate that examined nothing.
|
||||
#
|
||||
# ⚠️ test_loop.py TAKES ~93 SECONDS OF WALL CLOCK ON PURPOSE (its own
|
||||
# docstring says so, and says why: it drives the real `run_control()`
|
||||
# against a real wall-clock floor, and mocking the clock would leave the
|
||||
# assertion testing the mock). It is not hung. Do not "fix" it with a
|
||||
# shorter timeout - a 60 s limit was tried during CI-01 and reported
|
||||
# exactly the false hang the docstring predicts.
|
||||
#
|
||||
# ⚠️ WHAT THIS RUN DOES NOT COVER, stated because a pass here would
|
||||
# otherwise over-claim. test_freeze.py's third section wants the infra
|
||||
# repo's `sim/hwsim.py` to drive a real HTTP meter through the real
|
||||
# transport. admin/goodwe is PRIVATE (checked via the API) and this
|
||||
# workflow's GITHUB_TOKEN is minted for THIS repository only, so hwsim is
|
||||
# absent here and `find_hwsim()` returns None. The rest of the file runs
|
||||
# and passes. It does so SILENTLY - the file prints nothing to say the
|
||||
# hwsim section was skipped - so "test_freeze.py: PASS" below is a weaker
|
||||
# claim than it looks. That belongs to whoever owns test_freeze.py next;
|
||||
# naming it here is the least this gate can do about it.
|
||||
- name: the add-on's own tests
|
||||
run: |
|
||||
set -eu
|
||||
docker run --rm -v "$WS:/w:ro" goodwe-addon-checks:1 sh -eu -c '
|
||||
cd /w/goodwe-addon/goodwe_controller
|
||||
set -- test_*.py
|
||||
if [ "$1" = "test_*.py" ]; then
|
||||
echo "NO test_*.py FOUND - the mount is empty or the layout moved. NOTHING has been checked."
|
||||
exit 1
|
||||
fi
|
||||
echo "$# test file(s) to run"
|
||||
rc=0
|
||||
for f in "$@"; do
|
||||
start=$(date +%s)
|
||||
if python3 "$f" > /tmp/out 2>&1; then
|
||||
echo "PASS $f ($(( $(date +%s) - start ))s)"
|
||||
else
|
||||
echo "FAIL $f ($(( $(date +%s) - start ))s)"
|
||||
tail -40 /tmp/out
|
||||
rc=1
|
||||
fi
|
||||
done
|
||||
exit $rc
|
||||
'
|
||||
|
||||
- name: clean up
|
||||
if: always()
|
||||
run: |
|
||||
rm -rf "$WS" || true
|
||||
# Root-owned by this runner inside a directory the `homelab` user owns,
|
||||
# and sudo on that box is interactive-only, so the user cannot clean
|
||||
# this up and the job that made it has to.
|
||||
ls -1dt /home/homelab/ci/addon-checks-*/ 2>/dev/null | tail -n +6 | xargs -r rm -rf || true
|
||||
+19
-5
@@ -57,11 +57,25 @@ python3 test_control.py && python3 test_maintenance.py && python3 test_arbiter.p
|
||||
&& python3 test_loop.py
|
||||
```
|
||||
|
||||
`test_watchdog.py` covers SAFETY-02's logic and its trip path. Its headline
|
||||
validation is not here at all: `sim/replay_sign.py` in the infra repo drives the
|
||||
same module over the two captured RS485 days and must fire on all four of the
|
||||
2026-08-20 episodes and stay silent on 2026-08-23. That needs both checkouts —
|
||||
`GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py`.
|
||||
`test_watchdog.py` covers SAFETY-02's logic, its arming gate (derived from the
|
||||
real arbiter, not passed in), its trip path, and the fact that the latch survives
|
||||
an add-on restart. Its headline validation is not here at all: `sim/replay_sign.py`
|
||||
in the infra repo drives the same module over the two captured RS485 days and must
|
||||
fire on all four of the 2026-08-20 episodes and stay silent on 2026-08-23. That
|
||||
needs both checkouts:
|
||||
|
||||
```bash
|
||||
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py
|
||||
GOODWE_ADDON_REPO=/path/to/goodwe-addon python3 sim/replay_sign.py --stub
|
||||
```
|
||||
|
||||
The second run checks the grader still *discriminates* rather than merely still
|
||||
passing — a watchdog that never trips and one that always trips must both be
|
||||
rejected.
|
||||
|
||||
⚠️ **If you are testing the failsafe by hand, note that stopping and starting the
|
||||
add-on will not clear a trip.** That is the point of it; use the *Start / stop
|
||||
control* button twice, or delete `sign_tripped` from `/data/state.json`.
|
||||
|
||||
⚠️ `test_loop.py` takes about **95 seconds** (measured 93 s) and that is not a bug. It
|
||||
drives the real control loop, which sleeps 1 s a tick, eight times over, to prove a
|
||||
|
||||
@@ -1,5 +1,298 @@
|
||||
# Changelog
|
||||
|
||||
## Unreleased
|
||||
|
||||
**A computed setpoint over the rating now alarms instead of being clipped in
|
||||
silence (SAFETY-03).** The clamp was never the missing half - specs.md 10.3
|
||||
records an unclamped integrator climbing ~130 W per 4 s past 10 kW and reporting
|
||||
**14 768 W** while pinned at the 5 kW rail, and a silent clamp turns exactly that
|
||||
into a flat, legal-looking 5000 W hold. `write_setpoint()` - the one path every
|
||||
write takes, cycle, heartbeat, operator button and shutdown alike - now clamps to
|
||||
the **validated** `max_w` and reports whether the raw value differed, and
|
||||
`Controller.check_output_clamp()` raises `OUTPUT_CLAMP`: a persistent
|
||||
notification (`goodwe_output_clamp`), an `ERROR`, an event row and a red status
|
||||
banner. **Not a trip**: the clamped value is written and the loop keeps running,
|
||||
per 11.2's "clamp *and alarm*".
|
||||
|
||||
**The bound is `max_w` and nothing is `min()`ed at runtime.** Section 14 requires
|
||||
the loop clamp and the driver's `setpoint_limit_w` to agree, validated at startup
|
||||
with a refusal on mismatch - which CFG-01 already ships. The device range is
|
||||
still applied second, as defence in depth; after a successful validation it
|
||||
cannot engage, so if it ever does, that is louder than the first stage and it
|
||||
alarms too, naming the bound. No new config key: the guard's limit is the one
|
||||
the operator already set, and its cadence is a module constant.
|
||||
|
||||
**`Decision` grew `i_clamped` / `clamped` booleans, and that is the load-bearing
|
||||
part.** `reason` is one string that later stages overwrite - a cycle that clamps
|
||||
the integrator and is then slew limited reports `slew-limited`, and one that
|
||||
clamps while saturated reports `saturated-freeze`. Both *are* the winding case,
|
||||
so an alarm keyed on the string is silent on exactly the cycles it exists for:
|
||||
mutating main.py back onto `"clamp" in decision.reason` drops the 10.3 replay
|
||||
from 2 engagements to **0**. The flags are set where the clamp happens and are
|
||||
never overwritten. On a default install (`integrator_max_w` following `max_w`)
|
||||
the integrator bound is the one that bites and the output clamp is unreachable,
|
||||
so the integrator flag is the whole signal.
|
||||
|
||||
**Distinct from the saturation freeze, and checked in the negative.** A clamp is
|
||||
a *software* bug signal; saturation is the *hardware* failing to follow a legal
|
||||
command, and its action is to freeze the integrator, not to alarm. They share no
|
||||
reason code, notification id, status row or counter. `test_clamp.py` drives a
|
||||
loop that saturates for 10 consecutive cycles at 1.4 % of the rating and asserts
|
||||
zero clamp notifications, zero engagements, no log row and no status row - after
|
||||
first asserting that the saturation freeze *really did* engage, so the silence is
|
||||
an observation rather than a scenario that did nothing.
|
||||
|
||||
**The action log is coalesced per episode, and that was a real bug.**
|
||||
`log_event()` keeps 40 rows; one row per engagement flushed the entire ring
|
||||
within 40 cycles of a winding loop, and the first thing it evicted was
|
||||
SAFETY-18's own `METER FROZEN?` row - this guard silencing another guard's log.
|
||||
Caught by `test_freeze.py` going red, not by inspection. One row per episode now,
|
||||
carrying the exact engagement count read off the counter.
|
||||
|
||||
**A non-finite setpoint is refused, and it was worse than passing one through.**
|
||||
`nan` is loss of input (11.1 rule 1: command zero, keep commanding), not an
|
||||
out-of-range value. Measured: because every comparison against `nan` is False, a
|
||||
naive `max(-limit, min(limit, nan))` keeps its *first* argument and turns a `nan`
|
||||
into a command **at the full rating**, then reports it as a clamp engagement.
|
||||
|
||||
**Review fixes (PR #12).** Three, and the first was a behavioural regression
|
||||
this PR introduced: `clamp_to_rating()` **returned early** from the `max_w`
|
||||
stage, so the device bound - the "applied second, defence in depth" half - was
|
||||
reached only when the rating bound had NOT fired. The bigger the overshoot, the
|
||||
less the guard did. At `max_w` 5000 against a +-4000 device, +9999 emitted
|
||||
**+5000 W, outside the device range**, while a mere +4500 was correctly held to
|
||||
+4000. That undid the pre-PR guarantee "never send a value the device will
|
||||
reject outright" and undercut this module's own case for clamping to `max_w`
|
||||
rather than a runtime `min()`, which rests entirely on that stage catching a
|
||||
validation that did not run. Both stages now always run, the result names both
|
||||
bounds when both bite (`max_w+device`), and the property is asserted over a
|
||||
492-point sweep rather than on witness values - the defect was invisible to any
|
||||
single-value check that happened to sit inside one stage. No reachable
|
||||
production path was found for it (two validation gates and the arbiter bound sit
|
||||
in front), but latent is not harmless.
|
||||
|
||||
Two harness defects, both of the kind where a check cannot fail for the value it
|
||||
forbids: the hysteresis check issued `range(CLEAR_CYCLES - 1)` clean cycles,
|
||||
which at `CLEAR_CYCLES = 1` issues **zero** and passes while printing
|
||||
"0 clean cycles do NOT clear it" - green for the chatter setting the constant
|
||||
exists to prevent. And the re-assert check stimulated at `REASSERT_S + 9`, green
|
||||
for **any** value including 3600, i.e. the hour of silence the module promises
|
||||
not to produce. Both are now written in wall-clock terms that do not move when
|
||||
the constant does: **one** clean cycle must not clear the alarm, and a loop
|
||||
pinned across the 900 s capacity-tariff quarter must speak at least 5 times and
|
||||
on no more than 20 % of cycles. `CLEAR_CYCLES = 1`, `REASSERT_S = 3600` and
|
||||
`REASSERT_S = 0` each go red.
|
||||
|
||||
**`test_clamp.py`** (new, assert-based, no framework) covers the clamp
|
||||
arithmetic and its boundaries - exactly +-`max_w` is *not* an engagement - the
|
||||
alarm's edge/re-assert/hysteresis cadence, the 10.3 runaway replayed through the
|
||||
real `Controller.cycle()` against an unclamped transcription, the saturation
|
||||
negative, and the direct-write path. Six author mutations reproduced red,
|
||||
including "clamp kept, alarm deleted" (the historical build) and "alarm keyed on
|
||||
`reason`". Two of the check's own hypotheses about how the freeze and the clamp
|
||||
interact were **refused by the sweep** and rewritten to what it measured: a
|
||||
frozen cycle *can* clamp, and does so exactly when the integrator reverses.
|
||||
|
||||
`test_freeze.py`'s notification assertions now filter by `notification_id`
|
||||
rather than by service - the add-on raises more than one kind of notification,
|
||||
and its railing scenarios legitimately raise this one too.
|
||||
|
||||
**Cheap-window maintenance charging was unreachable at the shipped defaults, and
|
||||
now the config that makes it unreachable is refused (MAINT-04).** `config.yaml`
|
||||
shipped `max_w: 2000` against `maintenance_charge_w: 2500`. The cheap-window
|
||||
shaping files `Claim.limit(hi = -maintenance_charge_w)` against the supervised
|
||||
SAFETY limit's `lo = -max_w`, so `lo > hi` — the arbiter's clause 3, correctly
|
||||
resolved to **0 W** and logged as a CONTRADICTION. **Maintenance silently never
|
||||
charged in a cheap window on a default install**, and the only evidence read
|
||||
like a bug in the arbiter rather than like the two numbers an operator set.
|
||||
Measured against the real arbiter, loop asking +500 W:
|
||||
|
||||
```
|
||||
max_w=2000 hi=-2500 -> +0 W contradiction=True
|
||||
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
|
||||
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(cheap-window charge)
|
||||
```
|
||||
|
||||
`validate_startup_config()` now refuses `maintenance_charge_w > max_w` (rule 6),
|
||||
the same shape as CFG-01's `sign_disagree_w >= max_w`: a number the operator set,
|
||||
overridden by a layer they cannot see. Equality is reachable (`-max_w` is a
|
||||
single valid point) and deliberately not refused. Verified by starting the
|
||||
add-on on the pre-fix pair: exit 78, the refusal banner, no traceback.
|
||||
|
||||
**`maintenance_discharge_w` was checked, not assumed, and it is NOT the same
|
||||
case.** The shaping is not symmetric. The drain phase does not shape the loop,
|
||||
it OWNS the actuator — `Claim.set(P_MAINTENANCE, +discharge_w)` — and a SET is
|
||||
*clamped* by the limits above it rather than contradicted by them. 2500 against
|
||||
a 2000 W ceiling emits **+2000 W**, and the arbiter's own `explain()` prints
|
||||
`maintenance -> 2000 W, limited by supervised(max_w)` every cycle. Nothing is
|
||||
silent and energy still moves; the cycle completes slower (13.8 kWh usable at
|
||||
2000 W is ~6.9 h against the 720 min drain timeout). **Warned about, not
|
||||
refused.**
|
||||
|
||||
**The shipped defaults changed so the validator does not reject them.**
|
||||
`maintenance_charge_w` and `maintenance_discharge_w` are now **2000**, at the
|
||||
shipped `max_w`. `max_w` was deliberately NOT raised instead: it is the
|
||||
supervised safety ceiling and raising a default upward ships more power to every
|
||||
new install. Raising `max_w` (the reference install runs 5000) is what unlocks a
|
||||
faster maintenance cycle — raise it first, then these. `test_validate.py` now
|
||||
reads `config.yaml` itself and asserts the shipped numbers pass the rule, so a
|
||||
default that the validator refuses cannot ship again.
|
||||
|
||||
### ⚠️ Upgrading an existing default install: the add-on may refuse to start
|
||||
|
||||
An install still carrying `maintenance_charge_w: 2500` against `max_w: 2000`
|
||||
now meets rule 6 and **exits 78 with the refusal banner** instead of starting.
|
||||
That is the intended behaviour — the configuration was already broken, it was
|
||||
just silent about it — but an add-on that will not come back after an update
|
||||
needs the fix stated here rather than only in the log.
|
||||
|
||||
**The fix, either way: set `maintenance_charge_w` to `2000` or lower, OR raise
|
||||
`max_w` to `2500` or higher** (Settings → Add-ons → GoodWe RS485 Controller →
|
||||
Configuration), then start it. The banner in the log says the same thing and
|
||||
names both numbers.
|
||||
|
||||
Whether you hit this at all depends on whether the Supervisor kept the old
|
||||
value, and **both cases are covered above because we did not verify which one
|
||||
applies here.** The Supervisor merges an add-on's *stored* options over the
|
||||
defaults in `config.yaml`, so:
|
||||
|
||||
- **A key the operator never edited** re-derives from the new `config.yaml` and
|
||||
becomes 2000 on upgrade. Non-event, nothing to do.
|
||||
- **A key the operator did set** persists at 2500 and the add-on refuses to
|
||||
start until it is changed. Note this includes anyone who used the
|
||||
Configuration page's YAML editor, which writes the whole options block back —
|
||||
so "I never touched that field" is not a guarantee the old value is gone.
|
||||
|
||||
⚠️ **This is reasoned from the Supervisor's documented merge behaviour, not
|
||||
measured on the live install.** The reference install's stored options could not
|
||||
be read (`/api/hassio/` refuses a long-lived token) and probing it was out of
|
||||
scope — it regulates a real battery. It runs `max_w: 5000` and is unaffected
|
||||
either way.
|
||||
|
||||
⚠️ **Known, deliberately left, and worth a follow-up:** `main.py` and
|
||||
`maintenance.py` still fall back to **2500** when the key is absent from the
|
||||
options dict, while `config.yaml` and `validate.py` now say 2000. Unreachable on
|
||||
a Supervisor install (every key is always supplied) and reachable only from
|
||||
tests/`sim`. The real fix is one source of truth for option defaults, which is
|
||||
bigger than this ticket and touches files another ticket is in.
|
||||
|
||||
## 0.5.2
|
||||
|
||||
**A meter frozen at a wrong-but-fresh value now raises an alarm. It still is not
|
||||
stopped.** (SAFETY-18)
|
||||
|
||||
A meter that answers `200 OK` with a stale document forever is *arriving* on
|
||||
every poll, so every freshness mechanism in the stack reads it as healthy:
|
||||
`meter_max_age_s` is reset by each response, the firmware watchdog is fed by the
|
||||
heartbeat and by a sample age that never climbs, and the arbiter contributes only
|
||||
±`max_w`. The loop integrates a constant error and rails — replaying the real
|
||||
`compute()` at 15 s cycles, in 150/60/30 s at `max_w: 2000` for a meter frozen at
|
||||
350/1000/≥3000 W, and 360/135/75 s at `max_w: 5000`. **The live install runs
|
||||
`max_w: 5000`**, which is both the schema maximum and the device rating.
|
||||
|
||||
The new detector (`app/freeze.py`) is a **conjunction**, not the bare
|
||||
`unchanged_s` threshold TEL-05 measured and rejected:
|
||||
|
||||
unchanged_s ≥ meter_freeze_s AND |command| within 5 % of max_w
|
||||
|
||||
Both terms already existed and were already on the status page. They fail for
|
||||
independent reasons: at the converged point the command is nowhere near the rail,
|
||||
and at the rail against a real load the kWh registers move within seconds. At the
|
||||
shipped 300 s there is also a structural relation, not just a margin — the
|
||||
slowest a healthy 1 Wh register can tick and still look unchanged is 12 W, which
|
||||
is inside the 15 W deadband, so the command there is parked at 0 W and the two
|
||||
halves cannot both be true.
|
||||
|
||||
**Notification only, deliberately.** An HA persistent notification (fixed
|
||||
`notification_id`, so a repeat replaces rather than stacks), an `ERROR` log line,
|
||||
a UI event and a red status banner. No claim, no latch, no 0 W: a false trip
|
||||
parks the battery and the operator's next move is to switch the guard off; a
|
||||
false notification costs an alert. The trip is a separate decision that needs
|
||||
data from a real install.
|
||||
|
||||
- New option `meter_freeze_s` (default 300, range 60–3600, no "off").
|
||||
- **Only `meter_source: homewizard_local` is covered** — it is the only transport
|
||||
that sees the meter's own document. Everywhere else the status page says
|
||||
**NOT COVERED** rather than "armed".
|
||||
- `DOCS.md` now states the **capacity-tariff exposure** this does *not* close:
|
||||
`peak_cap_w` caps maintenance charging and nothing caps the loop, so a lying
|
||||
meter can drive a 5 kW unattended import, and ≥15 minutes of that sets the
|
||||
month's billed peak (measured: one 4998 W quarter moved a monthly peak from
|
||||
4832 → 5013 W). That cap is SAFETY-07.
|
||||
- `test_freeze.py` grades it in both directions: silent over 40 minutes of the
|
||||
live house's real converged capture (committed as
|
||||
`scenarios/p1-age-2026-08-26.jsonl.gz`), silent over an hour of TEL-05's
|
||||
low-power case where a bare threshold is shown to fire, and alarming on a
|
||||
genuinely frozen meter driven over real HTTP through the real
|
||||
`HomeWizardLocalSource` — against the rig's own `hwsim` `freeze` fault when the
|
||||
infra repo is reachable, an equivalent stub otherwise. Its negative twin is the
|
||||
load-bearing one: the same railed command against a meter that is still moving
|
||||
must stay silent at the same threshold.
|
||||
|
||||
## 0.5.1
|
||||
|
||||
**SAFETY-02's latch now survives an add-on restart, which is the difference
|
||||
between a latch and a pause.** `auto` was persisted and `sign_wd.tripped` was
|
||||
not, so reconstructing the `Controller` against the same store — exactly what a
|
||||
container restart does — brought it back **armed, into the same fault, with no
|
||||
operator involved**: `tripped=False`, banner back to `NOT READY`, and it resumed
|
||||
commanding (measured: −1000 W, −2000 W) before re-tripping 180 s later. Under a
|
||||
Supervisor that restarts a crashed add-on that is a loop of three-minute
|
||||
wrong-direction bursts — and "restart the add-on" is the first thing an operator
|
||||
looking at a `FAILSAFE` banner and a 0 W inverter will try.
|
||||
|
||||
`sign_tripped` and `sign_reason` are now `Store` keys beside the maintenance
|
||||
state, written the moment the trip happens (reason first, flag second, so a crash
|
||||
between the two can never persist a latch with no explanation) and restored in
|
||||
`Controller.__init__`. Cleared only by the operator's start. `DOCS.md` said "it
|
||||
does not clear itself"; that was false across a restart and now is not.
|
||||
|
||||
Also in this release, all of it review follow-up rather than new behaviour:
|
||||
|
||||
- **The arming gate is tested against the real arbiter.** It was the decision the
|
||||
whole ticket turns on and it was asserted in three comment blocks and verified
|
||||
by nothing — every case passed `following` in as a literal. `test_watchdog.py`
|
||||
now derives it from `resolve()` across twelve claim configurations, including
|
||||
the redirect case `winner == "loop"` alone would have got wrong and the `lo`
|
||||
limit that raises magnitude without flipping sign.
|
||||
- **The MQTT `status: "failsafe"` value is tested.** The check that claimed to
|
||||
cover it restated the assertion three lines above it and never touched the
|
||||
payload.
|
||||
- **A forward hazard written down where it will be read, and made to bite.**
|
||||
`winner == "loop"` disarms the watchdog under any higher-priority SET claim.
|
||||
Today only maintenance and the safety stops emit one and neither follows the
|
||||
meter; a peak-shaving strategy at `P_PEAK` **does**, and would blind the
|
||||
watchdog for every peak event.
|
||||
|
||||
The gate is now `watchdog.loop_is_following()`, called by both `main.py` and
|
||||
the test, for the same reason `disagrees()` was extracted: the test held a
|
||||
*transcription* of the shipped expression, so editing the shipped gate alone to
|
||||
`winner in ("loop", "peak")` left every suite green while the watchdog went
|
||||
blind. Two copies, and the one that drifts is the one doing the grading.
|
||||
|
||||
⚠️ Extracting it was not sufficient on its own. The realistic P_PEAK row —
|
||||
peak shaving asking for *more* than the loop — still could not detect the
|
||||
widened gate, because the magnitude term rejects it regardless and masks the
|
||||
winner term. A second row with peak asking for *less* isolates `winner` as the
|
||||
only deciding term, and that is the one that turns red.
|
||||
- **The worked example described a configuration that does not ship.** At the
|
||||
defaults `maintenance_charge_w` (2500) exceeds `max_w` (2000), so that claim is
|
||||
an arbiter *contradiction* resolving to 0 W, not a −2500 W charge. The example
|
||||
is now written at 1500 W. (The contradiction is a real pre-existing bug —
|
||||
a default cheap-window maintenance charge silently never happens — filed
|
||||
separately, deliberately not fixed here.)
|
||||
- **`disagrees()` is public**, so `sim/replay_sign.py` stops carrying its own copy
|
||||
of the predicate it grades.
|
||||
- `held_s` takes the clock instead of reading one, restoring the pure-function
|
||||
property the module advertises.
|
||||
- **The `sign_reason`-before-`sign_tripped` write ordering is enforced, not just
|
||||
documented.** Swapping the two lines used to pass every check. A store that
|
||||
fails the second write now proves the property the ordering exists for: what
|
||||
survives a crash mid-trip is a reason with no latch, never a latch with no
|
||||
explanation.
|
||||
- Measured figures corrected throughout: 93.4 % / 4212 of 17280 (was 92.9 % /
|
||||
4127 of 16349), per-cluster 0.3 / 0.9 / 10.5 / 0.0 %.
|
||||
|
||||
## 0.5.0
|
||||
|
||||
**SAFETY-02 — the sign-disagreement watchdog.** The add-on now watches whether
|
||||
@@ -23,7 +316,7 @@ module over the committed RS485 captures of both 2026-08-20 (the four episodes)
|
||||
and 2026-08-23 (healthy): **18 trips on the fault day, every one inside a window
|
||||
`NOTES.md` §4.7 accounts for, and 0 on the healthy day.** The four episodes do
|
||||
share one signature rather than merely resembling each other — sign agreement
|
||||
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 92.9 % on the healthy day.
|
||||
runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 93.4 % on the healthy day.
|
||||
|
||||
Three decisions worth knowing about:
|
||||
|
||||
|
||||
+165
-8
@@ -30,6 +30,10 @@ The inverter **holds its last command forever** — it has no meter-timeout. So:
|
||||
- The **optional RS485 e-stop** is the only thing that covers this machine
|
||||
dying. Without it, a failed host leaves the battery latched at its last
|
||||
command until someone intervenes.
|
||||
- This add-on **raises an alarm — and nothing more —** when the meter keeps
|
||||
answering with a reading that never changes while the command sits at the
|
||||
rail. See "The frozen-meter alarm" and, before you rely on it, "Capacity-tariff
|
||||
exposure of the grid-following loop".
|
||||
|
||||
**If anything looks wrong: stop the add-on.** That commands 0 W and the
|
||||
hardware holds it there.
|
||||
@@ -294,11 +298,20 @@ there. The banner reads `FAILSAFE`, the commissioning list says which two
|
||||
numbers disagreed and for how long, and the `Controller status` entity reports
|
||||
`failsafe`.
|
||||
|
||||
**It does not clear itself.** Pressing *Start / stop control* twice clears it.
|
||||
That is deliberate: commanding 0 W removes the command side of the comparison,
|
||||
so the disagreement always vanishes the instant the trip works, and a watchdog
|
||||
that took that as proof the fault was over would hand the inverter straight back
|
||||
to the loop that was driving the wrong way.
|
||||
**It does not clear itself, and restarting the add-on does not clear it either.**
|
||||
Pressing *Start / stop control* twice — stop, then start — is the only thing that
|
||||
does. That is deliberate on both counts:
|
||||
|
||||
- Commanding 0 W removes the command side of the comparison, so the disagreement
|
||||
always vanishes the instant the trip works. A watchdog that took that as proof
|
||||
the fault was over would hand the inverter straight back to the loop that was
|
||||
driving the wrong way, three minutes later, forever.
|
||||
- The trip is written to `/data/state.json` and restored on startup. Restarting
|
||||
the add-on is the first thing most people try when they see a red banner, and
|
||||
a latch that a restart clears would bring the controller back **armed, into the
|
||||
same fault, unattended** — and under a Supervisor that restarts a crashed add-on
|
||||
automatically, would do so in a loop. After a restart the banner, the 0 W and
|
||||
the recorded reason are all still there.
|
||||
|
||||
**What it is for.** This is a loop-integrity check: it asks whether the loop's
|
||||
output direction still matches the input state it was regulating. It catches a
|
||||
@@ -326,7 +339,7 @@ must not be mistaken for a fault.
|
||||
|
||||
Both numbers are measured rather than chosen, and are exposed only because the
|
||||
ticket requires defaults rather than constants. On the captured healthy day sign
|
||||
agreement is 92.9 %; on the four captured fault episodes it is 0.3 %, 0.9 %,
|
||||
agreement is 93.4 %; on the four captured fault clusters it is 0.3 %, 0.9 %,
|
||||
10.5 % and 0.0 %. There is no reason to move either value without a capture that
|
||||
says so.
|
||||
|
||||
@@ -405,8 +418,8 @@ help - see "Why the tuning is what it is".
|
||||
| `maintenance_enabled` | false | Enable the monthly cycle |
|
||||
| `maintenance_interval_days` | 28 | Minimum gap between cycles |
|
||||
| `maintenance_start_hour` | 10 | Hour of day a due cycle begins |
|
||||
| `maintenance_discharge_w` | 2500 | Drain rate (exports the surplus) |
|
||||
| `maintenance_charge_w` | 2500 | Charge ceiling, capped again by peak headroom |
|
||||
| `maintenance_discharge_w` | 2000 | Drain rate (exports the surplus). Above `max_w` it is **clamped** to `max_w` — the drain phase SETs the setpoint and the arbiter bounds it, saying so on the status page (`limited by supervised(max_w)`). Warned about, not refused: the cycle still completes, just slower |
|
||||
| `maintenance_charge_w` | 2000 | Charge ceiling, capped again by peak headroom. Must stay **at or below `max_w`** or the cheap-window shaping (`hi = -maintenance_charge_w`) contradicts the supervised limit (`lo = -max_w`), the arbiter resolves it to **0 W**, and maintenance silently never charges in a cheap window — **the add-on refuses to start** |
|
||||
| `maintenance_soc_floor` | 11 | Drain target — stay just above the inverter's own floor |
|
||||
| `maintenance_soc_target` | 99 | Charge target |
|
||||
| `maintenance_hold_min` | 120 | Hold at full so the BMS can balance |
|
||||
@@ -424,6 +437,150 @@ under `peak_cap_w`, and if the forecast goes over the cap the charge-only clamp
|
||||
is dropped so the battery can shave the peak instead. Money outranks the
|
||||
maintenance schedule.
|
||||
|
||||
#### Capacity-tariff exposure of the grid-following loop
|
||||
|
||||
⚠️ **`peak_cap_w` caps MAINTENANCE charging. It does not cap the loop.** The
|
||||
grid-following loop is bounded by `max_w` and by the device rating, and by
|
||||
nothing else. That is deliberate — the loop exists to *reduce* what crosses the
|
||||
meter, so under every healthy condition it lowers the peak rather than raising
|
||||
it — but it means one thing is true and worth writing down:
|
||||
|
||||
**If the meter lies, the loop will happily buy `max_w` from the grid for as long
|
||||
as the lie lasts, and no cap in this add-on stops it.** A meter frozen at a large
|
||||
export reads as "the house is exporting hard", the loop charges the battery to
|
||||
correct it, and the correction is a grid import. At the schema maximum
|
||||
`max_w: 5000` — which is what this house runs, and is also the device rating —
|
||||
that is a 5 kW unattended import.
|
||||
|
||||
The bill is not the energy. In the Belgian capaciteitstarief the month is billed
|
||||
on its highest quarter-hour average, so **fifteen minutes of this sets the whole
|
||||
month's peak.** A measured case: one 4998 W quarter moved a monthly peak from
|
||||
4832 W to 5013 W, and every day of that month was billed at the higher figure.
|
||||
|
||||
What exists today, and what does not:
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| `max_w` bounds the magnitude | ✅ — but the exposure IS the magnitude |
|
||||
| Maintenance charging capped under `peak_cap_w` | ✅ |
|
||||
| **Loop capped under `peak_cap_w`** | ❌ — not built. This is SAFETY-07 |
|
||||
| Frozen meter detected | ✅ on `homewizard_local` only, **alarm only** |
|
||||
| Frozen meter *stopped* | ❌ — the alarm does not command anything |
|
||||
| SoC guard on the loop | ❌ — the BMS is the only energy backstop |
|
||||
|
||||
So the frozen-meter alarm below **narrows the window; it does not close it.** On
|
||||
a capacity-tariff site where an unattended runaway is unacceptable, the mitigation
|
||||
today is operational: set `max_w` no higher than the loop actually needs (the
|
||||
tuning was measured at 2000 W and a 1.78 kW load step is tracked fine there), fit
|
||||
the e-stop, and watch for the alarm.
|
||||
|
||||
### The winding-loop alarm (the output clamp)
|
||||
|
||||
Every setpoint this add-on writes is clamped to `max_w` before it leaves the
|
||||
process, and **when that clamp actually engages, it alarms.** The clamp on its
|
||||
own is not the feature - this project already clipped, and the clipping is what
|
||||
hid the defect the guard exists for: with the inverter switched off entirely an
|
||||
unclamped integrator climbed ~130 W per 4 s past 10 kW and, pinned at the 5 kW
|
||||
rail, reported **14 768 W**. Clipped silently, that is a flat, legal-looking
|
||||
5000 W hold on every dashboard, and nothing anywhere says the loop asked for
|
||||
three times it.
|
||||
|
||||
**What "the rating" is.** The bound is `max_w`, and only `max_w`. It is already
|
||||
validated against the setpoint device's own range at startup - the add-on
|
||||
*refuses to start* if `max_w` exceeds what the device accepts (and again once
|
||||
ESPHome is up and the real rating is known), so by the time the loop runs the two
|
||||
numbers agree. The device range is applied a second time inside the write as
|
||||
defence in depth; after a successful validation it cannot bite, and if it ever
|
||||
does, that engagement alarms too and names the bound.
|
||||
|
||||
**Clamping is not saturation, and the two never share a channel.**
|
||||
|
||||
| | what it means | what happens |
|
||||
|---|---|---|
|
||||
| **clamp** | the *computed* value exceeded the rating | a software bug signal - something upstream is winding. **Alarm.** |
|
||||
| **saturation** | the inverter is not following a perfectly *legal* command | a hardware condition - freeze the integrator. **No alarm.** |
|
||||
|
||||
A loop can be legally saturated all day: a cold pack, a curtailed inverter, an
|
||||
export limit. Routing the clamp through a saturation-shaped alarm puts the bug
|
||||
signal inside the noise, which is the same silence as clipping quietly. They
|
||||
share no reason code, no notification id, no status row and no counter.
|
||||
|
||||
**It is an alarm, not a trip.** The clamped value is written and the loop keeps
|
||||
running - this is not the sign-disagreement failsafe, which commands 0 W. You
|
||||
get a persistent notification (`goodwe_output_clamp`, replaced rather than
|
||||
stacked), an `ERROR` in the log with the reason code `OUTPUT_CLAMP`, a row in
|
||||
the event list, and a red status banner while it is engaged. Once it clears, a
|
||||
warning row keeps the engagement count so the evidence does not vanish with the
|
||||
condition. Consecutive engagements share one event row carrying the exact count,
|
||||
because the event list keeps only 40 rows and a row per cycle would flush every
|
||||
other guard's entries out of it.
|
||||
|
||||
**There is nothing to configure**, deliberately. The bound is `max_w`, which you
|
||||
already set; giving the guard a limit of its own would be a second number that
|
||||
can disagree with the first, which is exactly the failure the startup validation
|
||||
exists to prevent. The alarm's cadence - first engagement, then re-asserted every
|
||||
30 s while it persists, cleared after 3 clean cycles - is fixed for the same
|
||||
reason `RAIL_FRAC` is: it describes the notification bus, not the plant.
|
||||
|
||||
WARNING: **on a default install the engagement you will see is the integrator's,
|
||||
not the output's.** The control law bounds the integrator to `max_w` and *then*
|
||||
derives the command from it, so the command itself can never come out over the
|
||||
rating unless `integrator_max_w` has been deliberately raised above `max_w`.
|
||||
Both are watched. A guard that watched only the emitted value would be silent on
|
||||
every standard configuration.
|
||||
|
||||
### The frozen-meter alarm
|
||||
|
||||
A meter that has died is easy — it stops answering, the sample age climbs past
|
||||
`meter_max_age_s`, the reading becomes missing, and the add-on and the ESP32 both
|
||||
command 0 W. A meter that keeps answering `200 OK` with a document that never
|
||||
changes is the hard one: **every freshness mechanism in the stack reads it as
|
||||
healthy**, because it really is arriving on every poll. The loop then integrates
|
||||
a constant error and winds to the rail, in 75–360 s at `max_w: 5000`.
|
||||
|
||||
The add-on alarms when **both** of these are true at once:
|
||||
|
||||
- the meter's own document (power figure *and* both kWh registers) has not
|
||||
changed for `meter_freeze_s` — 300 s by default; **and**
|
||||
- the command standing on the wire is at the rail, within 5 % of `max_w`.
|
||||
|
||||
Neither half is usable alone. A bare "unchanged for N seconds" rule false-trips
|
||||
at the exact operating point this controller aims for — at a converged −10 W a
|
||||
1 Wh register legitimately takes about six minutes to move — and a bare "at the
|
||||
rail" rule fires on any genuinely large load. Together they are safe in both
|
||||
directions, because a real railed condition means kilowatts still crossing the
|
||||
meter, and a kilowatt advances a 1 Wh register every 3.6 s.
|
||||
|
||||
**It is an alarm and nothing else.** It does not command 0 W, does not latch, and
|
||||
does not claim the actuator. A false trip here parks the battery; a false
|
||||
notification costs an alert. Turning it into a trip is a separate decision that
|
||||
needs data from a real install — and an answer to "what should the loop do
|
||||
instead", given that 0 W is itself an import of whatever the house is drawing.
|
||||
|
||||
When it fires you get a Home Assistant persistent notification
|
||||
(`goodwe_meter_frozen`, replaced rather than stacked on a repeat), an `ERROR` in
|
||||
the add-on log, an entry in the UI's event list, and a red banner on the status
|
||||
page. **The loop keeps running.** If the meter really is stuck, stop control from
|
||||
the add-on UI.
|
||||
|
||||
⚠️ **Only `meter_source: homewizard_local` is covered.** It is the only transport
|
||||
that reads the meter's own document; on `ha_dsmr`, `mqtt_p1`, `ha_signed` and
|
||||
`off` there is no signal to threshold and the status page says **NOT COVERED**
|
||||
rather than pretending the guard is armed.
|
||||
|
||||
| option | default | meaning |
|
||||
|---|---|---|
|
||||
| `meter_freeze_s` | 300 | Seconds of an unchanged measurement, *while the command is at the rail*, before the alarm |
|
||||
|
||||
Why 300 s: over 2399 s of this house at the converged operating point (mean grid
|
||||
−14.2 W, 1194 polls, 735 of them repeating the previous reading) the largest
|
||||
`unchanged_s` any sample sees is **8.0 s**, and the longest interval serving no
|
||||
distinct reading at all is **15.4 s**. There is also a structural reason not to
|
||||
lower it much: at 300 s the slowest a *healthy* register can tick and still look
|
||||
unchanged is 12 W, which is inside the 15 W deadband — so the command there is
|
||||
parked at 0 W and the two halves of the rule cannot both be true. At the schema
|
||||
floor of 60 s that figure is 60 W and only the margin is left.
|
||||
|
||||
### Site
|
||||
|
||||
| option | meaning |
|
||||
|
||||
@@ -0,0 +1,284 @@
|
||||
"""SAFETY-03 - the output clamp, and the alarm that makes it audible.
|
||||
|
||||
WHAT IT CATCHES, in one sentence: a control law that computes a setpoint the
|
||||
actuator cannot deliver, which every layer below it will happily clip to
|
||||
something legal-looking while the thing that produced it goes on winding.
|
||||
|
||||
THE CLAMP IS NOT THE DELIVERABLE. specs.md 10.3 is explicit that this project
|
||||
already clipped, and that the clipping is what hid the defect:
|
||||
|
||||
with the inverter switched off entirely, an unclamped integrator climbed
|
||||
~130 W per 4 s to over 10 kW and, pinned at the 5 kW rail, reported
|
||||
14 768 W
|
||||
|
||||
A clamp alone turns that into a silent, perfectly flat 5000 W hold. Every
|
||||
dashboard reads "commanded 5000 W", which is a legal number, and nothing
|
||||
anywhere says the loop asked for three times it. 11.2's watchdog row says
|
||||
"Clamp AND ALARM - the loop is winding"; the second verb is this module.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT "THE RATING" IS HERE, AND WHY IT IS ONE NUMBER AND NOT A MIN()
|
||||
|
||||
The card names two bounds and warns against choosing between them:
|
||||
|
||||
- `DriverCapabilities.setpoint_limit_w` (3.2), the inverter's own magnitude
|
||||
rating. In this add-on that arrives as the setpoint entity's `min`/`max`
|
||||
from `hass.limits()` - `Controller.dev_min` / `dev_max`.
|
||||
- `optimizer.loop.clamp_w` (14), the configured loop clamp. In this add-on
|
||||
that is the `max_w` option, which `Tuning.max_w` and the arbiter's
|
||||
`supervised` limit both already use.
|
||||
|
||||
14 says these two must AGREE, validated at startup with a refusal on
|
||||
mismatch - and that gate already ships: `validate_startup_config()` refuses
|
||||
`max_w > dev_max` and `-max_w < dev_min` (validate.py, problem 1), and
|
||||
run_control() re-runs it once ESPHome is up and the real rating is known.
|
||||
|
||||
So this guard clamps to `max_w`, THE VALIDATED VALUE, and does not `min()` it
|
||||
with the device rating at runtime. That is the card's instruction and it is also
|
||||
the only reading that keeps `max_w` meaningful: a silent runtime `min()` is
|
||||
precisely the "helper bounded to +-500 W under a loop clamped to 1500 W" failure
|
||||
the 14 warning box is about.
|
||||
|
||||
WARNING - THE DEVICE BOUND IS STILL APPLIED, SECOND, AND IT IS NOT REDUNDANT.
|
||||
After a successful validation `+-max_w` lies inside `[dev_min, dev_max]`, so the
|
||||
second stage is arithmetically a no-op and can never engage. If it DOES engage,
|
||||
the validation did not run or no longer holds - `hass.limits()` returns
|
||||
(None, None) whenever ESPHome is not up yet, and the range checks are skipped
|
||||
rather than guessed at - and that is a louder fault than the first stage, not a
|
||||
quieter one. It therefore alarms too, through the same channel, with the bound
|
||||
named. This is NOT SAFETY-20; nothing here changes what `freeze.py` measures its
|
||||
rail against.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHERE THE WIND ACTUALLY SHOWS UP - READ THIS BEFORE "SIMPLIFYING" THE CALLER
|
||||
|
||||
`control.compute()` bounds the integrator to `integrator_max_w or max_w` and
|
||||
THEN derives the command from it, so on a default install (`integrator_max_w`
|
||||
unset, i.e. following `max_w`) the command can never exceed `max_w` and the
|
||||
actuator-side clamp below IS UNREACHABLE. control.py says so in as many words:
|
||||
|
||||
SAFETY-03 ... must watch for THIS, not for "clamped" below.
|
||||
|
||||
An alarm wired only to this module's `ClampResult.engaged` would therefore be
|
||||
silent on the exact configuration the whole ticket is about. The winding is
|
||||
visible one layer up, at the integrator bound, and that is why `Decision` now
|
||||
carries `i_clamped` / `clamped` BOOLEANS and the caller ORs them in here.
|
||||
|
||||
AND WHY BOOLEANS RATHER THAN `Decision.reason`. `reason` is a single string that
|
||||
later stages overwrite: a cycle that clamps the integrator and is then slew
|
||||
limited reports "slew-limited", and one that clamps while saturated reports
|
||||
"saturated-freeze". Both are exactly the winding-into-a-rail case, and on the
|
||||
string the clamp signal is destroyed before anything can alarm on it. The two
|
||||
flags are set where the clamp happens and are never overwritten. A check in
|
||||
test_clamp.py drives that precise combination.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
DISTINCT FROM SATURATION - THIS IS ACCEPTANCE CRITERION 2, NOT A NICETY
|
||||
|
||||
clamp the COMPUTED value exceeded the rating. A software bug signal:
|
||||
something upstream is winding. Alarm, every engagement.
|
||||
saturation |command - inverter AC power| > `saturation_w` for
|
||||
`saturation_cycles`. The HARDWARE cannot follow a perfectly legal
|
||||
command. Action is "freeze the integrator" (11.2), not an alarm.
|
||||
|
||||
A loop can be legally saturated all day - a cold pack, a curtailed inverter, an
|
||||
export limit - so a saturation-shaped alarm is one an operator learns to ignore.
|
||||
Routing the clamp through it puts the bug signal inside the noise, which is the
|
||||
same silence 10.3 is complaining about. They share no reason code, no
|
||||
notification id, no status row and no counter.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
ANTI-FLOOD, WITHOUT GOING SILENT
|
||||
|
||||
A genuinely winding loop clamps on EVERY cycle for as long as it winds. One HA
|
||||
notification per cycle is how an operator learns to dismiss notifications
|
||||
unread, and this add-on already made that argument once (see the fixed
|
||||
`notification_id` note in main.check_meter_frozen).
|
||||
|
||||
So the two surfaces are split, deliberately:
|
||||
|
||||
- EVERY engagement is recorded, never deduplicated, and that record is what
|
||||
says how hard the loop is pushing. 15's action log is this add-on's
|
||||
`Controller.events`, and it gets a row from `write_setpoint()` on every
|
||||
engaged WRITE; `engagements` here counts every engaged CYCLE. The two layers
|
||||
are counted separately on purpose - the heartbeat re-writes an
|
||||
already-clamped value between cycles, so a per-write count would inflate and
|
||||
a per-cycle log would miss an out-of-cycle write.
|
||||
- THE NOTIFICATION fires on the rising edge and then RE-ASSERTS every
|
||||
`REASSERT_S`, so a loop pinned on the rail for an hour does not go quiet.
|
||||
- It DE-ASSERTS only after `CLEAR_CYCLES` consecutive clean cycles, which is
|
||||
the 10.2 hysteresis: a command sitting exactly on the rail dithers in and
|
||||
out of engagement by one quantisation step, and without this the alarm
|
||||
chatters.
|
||||
|
||||
`REASSERT_S` and `CLEAR_CYCLES` are module constants, not options, for the same
|
||||
reason `freeze.RAIL_FRAC` is: they describe the event bus, not the plant, and
|
||||
every knob 10.3 asked to keep exposed is a LOOP TUNING knob and is untouched by
|
||||
this module. No new config key is added anywhere - CFG-03 already has three
|
||||
places a default has to be kept in step and this ticket does not earn a fourth.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
NOT A TRIP
|
||||
|
||||
Clamping does not stop the loop and does not command 0 W. The clamped value is
|
||||
written and control continues, which is what 11.2 asks for ("Clamp and alarm")
|
||||
and what distinguishes this from SAFETY-01/02, whose action is 0 W. It follows
|
||||
that this must NOT drive the failsafe status - `publish()` keeps reporting
|
||||
"running", because the controller is.
|
||||
"""
|
||||
|
||||
import math
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
# The reason code, distinct from any saturation-freeze code by construction:
|
||||
# nothing else in this add-on uses it. See "DISTINCT FROM SATURATION".
|
||||
REASON_CODE = "OUTPUT_CLAMP"
|
||||
|
||||
# Re-assert the notification this often while the clamp stays engaged. 30 s is
|
||||
# the planning cadence (2.3), i.e. slow enough not to flood and fast enough
|
||||
# that a pinned loop is never quiet for a whole billing quarter.
|
||||
REASSERT_S = 30.0
|
||||
|
||||
# Consecutive clean cycles before the alarm de-asserts (10.2 hysteresis).
|
||||
CLEAR_CYCLES = 3
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class ClampResult:
|
||||
"""What the guard did, with the RAW value preserved.
|
||||
|
||||
AC 2 turns on "the raw computed value differed from the clamped one", so the
|
||||
raw value has to survive the call - a guard that returns only the applied
|
||||
number cannot be asked the question the acceptance criterion asks.
|
||||
"""
|
||||
|
||||
requested_w: float
|
||||
applied_w: float
|
||||
limit_w: float
|
||||
engaged: bool
|
||||
bound: str = "" # "" | "max_w" | "device" - which stage bit
|
||||
|
||||
def describe(self) -> str:
|
||||
return (f"{REASON_CODE}: the computed setpoint {self.requested_w:+.0f} W "
|
||||
f"was clamped to {self.applied_w:+.0f} W by the {self.bound} "
|
||||
f"bound (rating {self.limit_w:.0f} W) - something upstream is "
|
||||
f"winding")
|
||||
|
||||
|
||||
def is_commandable(value) -> bool:
|
||||
"""False for None, NaN and the infinities.
|
||||
|
||||
A non-finite setpoint is LOSS OF INPUT, not an out-of-range value, and
|
||||
11.1 rule 1 says loss of input means command zero and keep commanding. It
|
||||
must not reach the clamp arithmetic: `min(limit, nan)` returns nan on
|
||||
CPython, so a nan would sail straight through a naive clamp and then report
|
||||
`engaged` True on the `applied != requested` test - because nan != nan - i.e.
|
||||
a transport bug filed in the winding-loop counter, with a nan on the wire.
|
||||
"""
|
||||
if value is None:
|
||||
return False
|
||||
try:
|
||||
return math.isfinite(float(value))
|
||||
except (TypeError, ValueError):
|
||||
return False
|
||||
|
||||
|
||||
def clamp_to_rating(requested_w, limit_w, dev_min=None, dev_max=None) -> ClampResult:
|
||||
"""Bound a computed setpoint to the validated rating. The ONLY clamp.
|
||||
|
||||
`limit_w` the validated magnitude bound - `max_w`. Symmetric, because
|
||||
3.2 calls `setpoint_limit_w` a MAGNITUDE clamp: it binds import
|
||||
(+) and export (-) identically.
|
||||
`dev_min` / `dev_max` the device's own asymmetric range, applied second and
|
||||
expected never to bite. See the module note.
|
||||
|
||||
Public, and the predicate lives here rather than in the test, for the reason
|
||||
`freeze.looks_frozen()` gives: a safety expression transcribed into its own
|
||||
check is one copy plus a future disagreement about what the check means.
|
||||
|
||||
EXACTLY +-`limit_w` IS NOT AN ENGAGEMENT. The bound is inclusive; a loop
|
||||
resting on the rail is doing what it was told, and alarming there would fire
|
||||
on every healthy full-power hour.
|
||||
"""
|
||||
requested = float(requested_w)
|
||||
limit = abs(float(limit_w))
|
||||
|
||||
# ⚠️ BOTH STAGES ALWAYS RUN. THIS USED TO `return` FROM THE FIRST ONE, AND
|
||||
# THAT WAS A REGRESSION AGAINST THE CODE IT REPLACED. `write_setpoint()`
|
||||
# previously clamped to the device range unconditionally, under the comment
|
||||
# "never send a value the device will reject outright"; short-circuiting here
|
||||
# meant the device bound was applied only when the rating bound had NOT
|
||||
# fired, i.e. THE BIGGER THE OVERSHOOT THE LESS THE GUARD DID. Measured on
|
||||
# the shipped function at max_w 5000 against a device of +-4000:
|
||||
#
|
||||
# +9999 -> +5000 bound='max_w' <- outside the device range
|
||||
# +4500 -> +4000 bound='device'
|
||||
#
|
||||
# It also undercut this module's own argument for clamping to `max_w` rather
|
||||
# than a runtime `min()`, which rests entirely on this stage catching the
|
||||
# case where the startup validation did not run.
|
||||
applied = max(-limit, min(limit, requested))
|
||||
bound = "max_w" if applied != requested else ""
|
||||
|
||||
# Second stage. Arithmetically dead after a successful startup validation -
|
||||
# and therefore worth alarming on precisely BECAUSE it fired.
|
||||
if dev_min is not None and dev_max is not None:
|
||||
bounded = max(float(dev_min), min(float(dev_max), applied))
|
||||
if bounded != applied:
|
||||
bound = "device" if not bound else "max_w+device"
|
||||
applied = bounded
|
||||
|
||||
return ClampResult(requested, applied, limit, applied != requested, bound)
|
||||
|
||||
|
||||
class ClampWatchdog:
|
||||
"""One instance per controller. Counts every engagement, alarms sparsely.
|
||||
|
||||
`note()` is called once per write with whether the clamp bit; the caller ORs
|
||||
in the loop's own `i_clamped` / `clamped` flags, which is where the winding
|
||||
is actually visible on a default install (see the module note).
|
||||
"""
|
||||
|
||||
def __init__(self):
|
||||
self.active = False
|
||||
self.engagements = 0 # every engagement, never deduplicated
|
||||
self.episodes = 0 # rising edges
|
||||
self.since: datetime | None = None
|
||||
self.last_alarm: datetime | None = None
|
||||
self.reason = ""
|
||||
self.clean_cycles = 0
|
||||
|
||||
def note(self, engaged: bool, reason: str, now: datetime) -> bool:
|
||||
"""Advance one cycle. True when the caller should raise the alarm.
|
||||
|
||||
`now` is the caller's clock, the same discipline as
|
||||
`SignWatchdog.evaluate()` and `FreezeWatchdog.evaluate()`.
|
||||
"""
|
||||
if engaged:
|
||||
self.engagements += 1
|
||||
self.clean_cycles = 0
|
||||
self.reason = reason
|
||||
if not self.active:
|
||||
self.active = True
|
||||
self.since = now
|
||||
self.episodes += 1
|
||||
self.last_alarm = now
|
||||
return True
|
||||
# Still engaged: re-assert on the slow cadence, not every cycle.
|
||||
if (self.last_alarm is None
|
||||
or (now - self.last_alarm).total_seconds() >= REASSERT_S):
|
||||
self.last_alarm = now
|
||||
return True
|
||||
return False
|
||||
|
||||
if not self.active:
|
||||
return False
|
||||
self.clean_cycles += 1
|
||||
if self.clean_cycles >= CLEAR_CYCLES:
|
||||
self.active = False
|
||||
self.since = None
|
||||
self.last_alarm = None
|
||||
self.reason = ""
|
||||
self.clean_cycles = 0
|
||||
return False
|
||||
@@ -64,6 +64,23 @@ class Decision:
|
||||
# and quantisation. Carry it back in as `i_w` next cycle; that is what keeps
|
||||
# it a separate quantity from the command.
|
||||
i_w: float = 0.0
|
||||
# SAFETY-03. Did a clamp actually engage this cycle - i.e. did the RAW
|
||||
# computed value differ from the bounded one?
|
||||
#
|
||||
# ⚠️ THESE EXIST BECAUSE `reason` CANNOT ANSWER THAT QUESTION. `reason` is
|
||||
# one string and every later stage overwrites it: a cycle that clamps the
|
||||
# integrator and is then slew limited reports "slew-limited", and one that
|
||||
# clamps while saturated reports "saturated-freeze". Both ARE the winding
|
||||
# case, and on the string the clamp signal is gone before anything can alarm
|
||||
# on it. These two are written where the clamp happens and are never
|
||||
# overwritten, so they mean exactly what they say and nothing else.
|
||||
#
|
||||
# `i_clamped` is the one that fires on a default install: the integrator
|
||||
# bound is reached first, so `clamped` is unreachable unless
|
||||
# `integrator_max_w` is deliberately set above `max_w`. Alarm on BOTH - see
|
||||
# the comment at the bound below, and clamp.py.
|
||||
i_clamped: bool = False
|
||||
clamped: bool = False
|
||||
|
||||
|
||||
def compute(
|
||||
@@ -188,7 +205,8 @@ def compute(
|
||||
# bound is not. It is what makes the worst-case unwind time finite and
|
||||
# knowable instead of a function of how long the error happened to stand.
|
||||
bounded = max(-limit, min(limit, i_w))
|
||||
if bounded != i_w:
|
||||
i_clamped = bounded != i_w
|
||||
if i_clamped:
|
||||
# ⚠️ SAFETY-03 (alarm whenever the loop winds into a rail) must watch
|
||||
# for THIS, not for "clamped" below. At the default limit == max_w the
|
||||
# integrator bound is reached first and the command derived from it can
|
||||
@@ -209,7 +227,8 @@ def compute(
|
||||
# --- ORDER MATTERS: clamp -> slew -> freeze ----------------------------
|
||||
# An early draft applied a floor after the clamp and let demand escape it.
|
||||
target = max(-tuning.max_w, min(tuning.max_w, want))
|
||||
if target != want:
|
||||
clamped = target != want
|
||||
if clamped:
|
||||
reason = "clamped"
|
||||
|
||||
slewed = max(prev_w - tuning.slew_w, min(prev_w + tuning.slew_w, target))
|
||||
@@ -235,7 +254,8 @@ def compute(
|
||||
step = max(1, int(tuning.step_w))
|
||||
target = round(target / step) * step
|
||||
|
||||
return Decision(float(target), sat_count, frozen, reason, float(i_w))
|
||||
return Decision(float(target), sat_count, frozen, reason, float(i_w),
|
||||
i_clamped, clamped)
|
||||
|
||||
|
||||
def maintenance_charge_floor(
|
||||
|
||||
@@ -0,0 +1,275 @@
|
||||
"""SAFETY-18 - the frozen-but-fresh meter detector.
|
||||
|
||||
WHAT IT CATCHES, in one sentence: a meter that keeps answering 200 OK with a
|
||||
document that never changes, which every freshness mechanism in this stack reads
|
||||
as perfectly healthy while the loop winds to the rail and stays there.
|
||||
|
||||
THE FAILURE NEEDS NO FAULT ANYWHERE ELSE. A frozen-but-talking meter is
|
||||
*arriving* on every poll, so:
|
||||
|
||||
- `meter_max_age_s` is structurally blind. Every response resets the arrival
|
||||
stamp (p1.py, `HomeWizardLocalSource`), so the age never climbs. Age catches
|
||||
a meter that stops TALKING; this one stops CHANGING.
|
||||
- firmware layer 1 is fed. Its watchdog keys on setpoint staleness, which the
|
||||
heartbeat satisfies, and on `sensor.goodwe_p1_sample_age`, which a talking
|
||||
meter satisfies.
|
||||
- the arbiter contributes only the device rating and +-`max_w` - it bounds the
|
||||
magnitude, which is the number this fault drives us to, not away from.
|
||||
- there is no SoC guard on the grid-following loop at all. `soc_floor` belongs
|
||||
to the maintenance cycle; the BMS is the sole energy backstop.
|
||||
|
||||
The loop reads a constant error and integrates it. Time from freeze to the rail,
|
||||
replaying the real `control.compute()` at 15 s cycles:
|
||||
|
||||
meter frozen at to rail, max_w 2000 to rail, max_w 5000
|
||||
350 W 150 s 360 s
|
||||
1000 W 60 s 135 s
|
||||
>= 3000 W 30 s 75 s
|
||||
|
||||
⚠️ THE LIVE INSTALL RUNS `max_w: 5000`, which is both the schema maximum and the
|
||||
device rating, so the right-hand column is the one that describes this house.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
THIS HAS A EURO FIGURE, AND IT IS THE REASON THE TICKET IS P1
|
||||
|
||||
`maintenance_charge_floor()` caps MAINTENANCE charging against `peak_cap_w`. The
|
||||
grid-following loop is not capped by anything but `max_w`. A meter frozen
|
||||
reading a large export drives a 5 kW unattended grid IMPORT, and >= 15 minutes
|
||||
of that sets the month's billed capaciteitstarief peak: specs.md:583 records a
|
||||
measured case where a single 4998 W quarter moved a monthly peak from 4832 W to
|
||||
5013 W and billed the whole month at it.
|
||||
|
||||
⚠️ THIS CUT DOES NOT CAP THAT. It notifies. See DOCS.md, "Capacity-tariff
|
||||
exposure of the grid-following loop", and SAFETY-07.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY IT IS A CONJUNCTION AND NOT AN `unchanged_s` THRESHOLD
|
||||
|
||||
`unchanged_s` (p1.py) already measures exactly the right thing: seconds since
|
||||
the meter served a DIFFERENT measurement, fingerprinted over the power figure
|
||||
and both energy registers. It is computed, it is on the status page, and TEL-05
|
||||
deliberately refused to threshold it - correctly:
|
||||
|
||||
this controller regulates grid power toward ~0 W, and at a converged -10 W
|
||||
the export register takes about six minutes to advance by its 1 Wh
|
||||
resolution while the power figure legitimately repeats.
|
||||
|
||||
So a bare `unchanged_s > N` false-trips at the exact operating point we aim for,
|
||||
and `p1.py` says as much in a note that ends "whoever wires a freeze detector
|
||||
must handle the low-power case first". This is that handling, and it is not a
|
||||
smaller number:
|
||||
|
||||
unchanged_s >= hold_s AND |commanded_w| is at the rail
|
||||
|
||||
The second term is what TEL-05's case cannot satisfy. At the converged point the
|
||||
command is nowhere near +-`max_w`; on the 40 minutes of live converged behaviour
|
||||
in `sim/scenarios/p1-age-2026-08-26.jsonl.gz` the meter never once leaves
|
||||
+-500 W, so the loop never even approaches a 5000 W rail. And the reverse case -
|
||||
a command genuinely pinned at the rail by a real 8 kW load - cannot satisfy the
|
||||
FIRST term, because a real railed condition means kilowatts still crossing the
|
||||
meter, and a kilowatt advances a 1 Wh register every 3.6 s.
|
||||
|
||||
The two terms fail for independent reasons. That is the whole design.
|
||||
|
||||
⚠️ AND THE SECOND HALF OF THAT WAS MEASURED ON THE RIG, WITH A RESULT WORTH
|
||||
READING CAREFULLY. Driving the real transport against the rig's own hwsim under
|
||||
+8000 W of house load - a genuinely railed command, meter perfectly healthy - the
|
||||
POWER FIGURE DID NOT MOVE AT ALL: `active_power_w` sat at exactly 10130.0 W for
|
||||
26 consecutive polls. What kept `unchanged_s` pinned at 0.0 s was the kWh
|
||||
registers advancing, and nothing else.
|
||||
|
||||
So the register terms in `measurement_fingerprint()` are not belt-and-braces
|
||||
here, they are the entire negative case. A freeze detector fingerprinted on the
|
||||
power figure alone would have raised a false alarm on that rig run - a healthy
|
||||
meter, a real load, a correctly railed command - which is the exact failure mode
|
||||
that gets a safety guard switched off. Anyone tempted to simplify the fingerprint
|
||||
should read that run first.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHERE `hold_s` COMES FROM
|
||||
|
||||
Measured on `sim/scenarios/p1-age-2026-08-26.jsonl.gz` - 2399 s (40 min) of the
|
||||
live house at the converged operating point, mean grid -14.2 W, 1194 polls:
|
||||
|
||||
polls that repeated the previous reading 735 of 1193 (61.6 %)
|
||||
distinct-reading transitions 458
|
||||
median gap between distinct readings 6.0 s
|
||||
p95 gap 6.0 s
|
||||
LARGEST `unchanged_s` any sample observes 8.0 s
|
||||
longest interval serving no distinct reading 15.4 s
|
||||
samples outside +-500 W 0
|
||||
|
||||
The default 300 s is 37x the largest `unchanged_s` this house has been recorded
|
||||
producing while converged, and 19.5x the longest interval in which it served no
|
||||
distinct reading at all. The two figures differ because the capture has an 11.4 s
|
||||
hole in its OWN polling; the second is quoted because it is the pessimistic one.
|
||||
300 s is not fitted to either margin - it is picked as "clearly past any
|
||||
plausible register-tick interval, and clearly inside the 900 s quarter that bills
|
||||
the capacity tariff". test_freeze.py re-measures both every run, so this
|
||||
paragraph cannot quietly stop being true.
|
||||
|
||||
⚠️ BE PRECISE ABOUT WHAT THAT CAPTURE PROVES. It is POWER-ONLY - the shipped
|
||||
fingerprint also covers both kWh registers, so a real `unchanged_s` on that data
|
||||
can only be shorter, never longer, which makes it a conservative measurement of
|
||||
the converged case. But it does NOT on its own refute a bare `unchanged_s`
|
||||
threshold, and saying it did would be exactly the overstatement this project
|
||||
keeps having to walk back: at 8 s worst, a bare 300 s threshold is silent on it
|
||||
too. The case that refutes the bare threshold is the one below, which no capture
|
||||
of THIS meter contains because this meter's power figure jitters.
|
||||
|
||||
The floor on the other side: at the rail, the smallest residual grid flow that
|
||||
still ticks a 1 Wh register inside 300 s is 12 W. Any condition that genuinely
|
||||
pins this loop at +-5000 W has three orders of magnitude more than that crossing
|
||||
the meter.
|
||||
|
||||
⚠️ AND THOSE TWO NUMBERS DO NOT MERELY HAVE MARGIN - THEY CANNOT BOTH BE TRUE.
|
||||
The worry the conjunction has to answer is "a HEALTHY meter whose register is
|
||||
slower than `hold_s`". At 300 s that is |grid| < 12 W. The shipped `deadband_w`
|
||||
is 15 W, so anywhere the register is that slow the control law is already inside
|
||||
its deadband and the command is parked - the rail term is not merely unlikely to
|
||||
be true there, it is 0 W. The two terms are mutually exclusive by construction
|
||||
at the defaults, not just far apart, and the check re-derives that every run.
|
||||
|
||||
That relationship is the one to protect. `hold_s` may be lowered only while
|
||||
3600/hold_s stays under `deadband_w`; at the schema floor of 60 s that is 60 W
|
||||
against a 15 W deadband, and the mutual exclusion is gone. A 60 s `meter_freeze_s`
|
||||
is a supported configuration that gives up this argument and keeps only the
|
||||
margin - do not set one without a capture that says the margin is enough.
|
||||
|
||||
⚠️ WHAT `hold_s` DOES NOT BUY IS DETECTION SPEED. The alert lands at
|
||||
max(hold_s, time-to-rail) after the freeze, so at the shipped default and
|
||||
`max_w: 5000` that is 300-360 s. The rail is REACHED first, from 75 s. A
|
||||
notification is not a brake; see the DOCS.md note.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
THE RAIL TERM, PRECISELY
|
||||
|
||||
abs(commanded_w) >= RAIL_FRAC * max_w
|
||||
|
||||
`commanded_w` is the EMITTED setpoint - what the arbiter resolved and
|
||||
`write_setpoint()` put on the wire - not the loop's raw wish, for the same
|
||||
reason SAFETY-02 uses the emitted value: the wire carries the emitted number.
|
||||
|
||||
RAIL_FRAC is 0.95 and is a constant rather than an option. The command is
|
||||
quantised to `step_w` (max 100) and clamped to `max_w` (min 100), so at the rail
|
||||
the emitted value IS `max_w` on every schema-legal combination; the 5 % is slack
|
||||
for a device rating that clips `max_w` slightly in `write_setpoint()`, not a
|
||||
tuning knob. Making it configurable would offer a way to widen the one term that
|
||||
carries the whole no-false-positive argument.
|
||||
|
||||
⚠️ NOT GATED ON `following`, and that is deliberate. A maintenance charge
|
||||
commands against the meter on purpose and can sit at the rail for hours - but it
|
||||
does so while pushing kilowatts through the meter, so the FIRST term is what
|
||||
excludes it, and it excludes it on physics rather than on bookkeeping. Gating on
|
||||
`following` as well would additionally blind the detector to a maintenance phase
|
||||
running against a meter that really has frozen, which is the same fault with a
|
||||
worse actuator behind it.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
NOTIFY, DO NOT TRIP
|
||||
|
||||
First cut is an alarm and nothing else: an HA persistent notification, an ERROR
|
||||
in the log, an event on the status page, and a failed check row. It does NOT
|
||||
claim the actuator, does NOT file a P_SAFETY claim and does NOT latch.
|
||||
|
||||
That is a deliberate ordering of costs, not timidity. A false trip here parks
|
||||
the battery - on a house that is running this loop precisely to avoid buying
|
||||
power at the wrong moment - and the operator's response to a parked battery is
|
||||
to switch the guard off. A false notification costs one alert. The trip is a
|
||||
separate decision that has to be earned with observed data from a real install,
|
||||
and it needs an answer to a question this cut does not have one for: what should
|
||||
the loop do instead, given that 0 W is itself a grid import of whatever the
|
||||
house is drawing.
|
||||
|
||||
⚠️ TRANSPORT-CONDITIONAL. `unchanged_s` exists ONLY on `homewizard_local`,
|
||||
because it is the only transport that sees the meter's own document. Under
|
||||
`ha_dsmr`, `mqtt_p1`, `ha_signed` and `meter_source: off` this detector is
|
||||
silent and the exposure above is uncovered. The caller passes None and gets
|
||||
False; there is no half-measure available on those paths, and pretending
|
||||
otherwise would be worse than the gap.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime
|
||||
|
||||
# See "THE RAIL TERM, PRECISELY" above. A constant, on purpose.
|
||||
RAIL_FRAC = 0.95
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class FreezeWatchdogConfig:
|
||||
"""Default, not a constant - config.yaml carries `meter_freeze_s`."""
|
||||
|
||||
hold_s: float = 300.0
|
||||
|
||||
|
||||
def rail_w(max_w) -> float:
|
||||
"""The magnitude at or above which a command counts as railed."""
|
||||
return abs(float(max_w)) * RAIL_FRAC
|
||||
|
||||
|
||||
def looks_frozen(unchanged_s, commanded_w, max_w,
|
||||
cfg: FreezeWatchdogConfig) -> bool:
|
||||
"""The predicate, and the ONLY place the conjunction is written down.
|
||||
|
||||
Public for the same reason `watchdog.disagrees()` is: the checks that grade
|
||||
it must assert on THE SHIPPED EXPRESSION. A safety predicate transcribed
|
||||
into its own test is one copy plus a future disagreement about what the
|
||||
check means, and the copy that drifts is always the one doing the grading.
|
||||
|
||||
`unchanged_s` seconds since the meter served a different measurement, or
|
||||
None on a transport that cannot know (see the module note).
|
||||
`commanded_w` the EMITTED setpoint standing on the wire.
|
||||
`max_w` the configured output bound the rail is measured against.
|
||||
"""
|
||||
if unchanged_s is None or commanded_w is None or not max_w:
|
||||
return False
|
||||
return (float(unchanged_s) >= cfg.hold_s
|
||||
and abs(float(commanded_w)) >= rail_w(max_w))
|
||||
|
||||
|
||||
class FreezeWatchdog:
|
||||
"""One instance per controller, evaluated once per control cycle.
|
||||
|
||||
Level-triggered state with an EDGE for the alarm: `evaluate()` returns True
|
||||
on the cycle the conjunction first becomes true and False on every cycle
|
||||
after, so the caller raises one notification per episode rather than one
|
||||
every second. `active` is the level, for the status page.
|
||||
|
||||
No latch, deliberately - see "NOTIFY, DO NOT TRIP". A latch exists so a trip
|
||||
cannot erase its own evidence by working; nothing here acts, so there is
|
||||
nothing to erase. When the meter starts moving again the alert clears
|
||||
itself, which is the honest report of the state.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: FreezeWatchdogConfig | None = None):
|
||||
self.cfg = cfg or FreezeWatchdogConfig()
|
||||
self.active = False
|
||||
self.since: datetime | None = None
|
||||
self.reason = ""
|
||||
self.episodes = 0
|
||||
|
||||
def evaluate(self, unchanged_s, commanded_w, max_w, now: datetime) -> bool:
|
||||
"""Advance one cycle. Returns True ONLY on the rising edge.
|
||||
|
||||
`now` is the caller's clock so this stays testable and replayable - the
|
||||
same discipline as `SignWatchdog.evaluate()`.
|
||||
"""
|
||||
if not looks_frozen(unchanged_s, commanded_w, max_w, self.cfg):
|
||||
self.active = False
|
||||
self.since = None
|
||||
self.reason = ""
|
||||
return False
|
||||
|
||||
self.reason = (
|
||||
f"METER_FROZEN: the meter has answered {float(unchanged_s):.0f} s "
|
||||
f"without its measurement changing while the command stands at "
|
||||
f"{float(commanded_w):+.0f} W, at the {float(max_w):.0f} W rail "
|
||||
f"(limits: unchanged over {self.cfg.hold_s:.0f} s, command over "
|
||||
f"{rail_w(max_w):.0f} W)")
|
||||
if self.active:
|
||||
return False
|
||||
self.active = True
|
||||
self.since = now
|
||||
self.episodes += 1
|
||||
return True
|
||||
+306
-31
@@ -36,12 +36,17 @@ from .arbiter import (
|
||||
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_SAFETY, Claim, resolve,
|
||||
)
|
||||
from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk
|
||||
from .clamp import (
|
||||
REASON_CODE as CLAMP_REASON, ClampResult, ClampWatchdog, clamp_to_rating,
|
||||
is_commandable,
|
||||
)
|
||||
from .freeze import FreezeWatchdog, FreezeWatchdogConfig, rail_w
|
||||
from .hass import HomeAssistant
|
||||
from .maintenance import IDLE, MaintConfig, Maintenance
|
||||
from .mqtt import MqttPublisher
|
||||
from .p1 import P1Ingest, build_source, is_enabled
|
||||
from .validate import ConfigRefused, refuse, validate_startup_config
|
||||
from .watchdog import SignWatchdog, SignWatchdogConfig
|
||||
from .watchdog import SignWatchdog, SignWatchdogConfig, loop_is_following
|
||||
from . import web
|
||||
|
||||
OPTIONS_PATH = "/data/options.json"
|
||||
@@ -105,10 +110,52 @@ class Controller:
|
||||
)
|
||||
|
||||
# SAFETY-02. One instance, one actuator, one cadence - see watchdog.py.
|
||||
self.sign_wd = SignWatchdog(SignWatchdogConfig(
|
||||
min_w=float(opts.get("sign_disagree_w", 300)),
|
||||
hold_s=float(opts.get("sign_disagree_s", 180)),
|
||||
))
|
||||
#
|
||||
# ⚠️ RESTORED FROM THE STORE, and that is the difference between a latch
|
||||
# and a pause. A trip held only in memory is cleared by the one action an
|
||||
# operator staring at a FAILSAFE banner is most likely to take - restart
|
||||
# the add-on - and the controller then comes back armed, into the fault,
|
||||
# with nobody involved. Restored here, the banner and the 0 W survive the
|
||||
# restart and only `auto_toggle` clears them.
|
||||
self.sign_wd = SignWatchdog(
|
||||
SignWatchdogConfig(
|
||||
min_w=float(opts.get("sign_disagree_w", 300)),
|
||||
hold_s=float(opts.get("sign_disagree_s", 180)),
|
||||
),
|
||||
tripped=bool(store.data.get("sign_tripped", False)),
|
||||
reason=str(store.data.get("sign_reason", "") or ""),
|
||||
)
|
||||
if self.sign_wd.tripped:
|
||||
_LOG.error("SAFETY-02 was TRIPPED before this restart and stays "
|
||||
"tripped: %s. The inverter is held at 0 W. Restarting the "
|
||||
"add-on does not clear this - start control from the UI "
|
||||
"once you know why the command opposed the meter.",
|
||||
self.sign_wd.reason or "(reason not recorded)")
|
||||
|
||||
# SAFETY-18. The frozen-but-fresh meter detector - see freeze.py for why
|
||||
# it is a conjunction and not an `unchanged_s` threshold, and for the
|
||||
# measurements behind the default.
|
||||
#
|
||||
# ⚠️ NOT restored from the store, unlike SAFETY-02's latch, and the
|
||||
# asymmetry is the point: this one does not latch because it does not
|
||||
# act. A restart re-derives its state from the meter within one
|
||||
# `meter_freeze_s` window, and until then the honest report is "not
|
||||
# alarming yet" rather than an alarm nobody can clear.
|
||||
self.freeze_wd = FreezeWatchdog(
|
||||
FreezeWatchdogConfig(hold_s=float(opts.get("meter_freeze_s", 300))))
|
||||
|
||||
# SAFETY-03. The output clamp's alarm - see clamp.py for why the clamp
|
||||
# itself is the cheap half.
|
||||
#
|
||||
# ⚠️ NO CONFIG OF ITS OWN, on purpose. The bound it clamps to is `max_w`,
|
||||
# which is already an option, already validated against the device's
|
||||
# rating at startup, and already used by Tuning and the arbiter. Giving
|
||||
# this a second key would be a fourth place a limit has to be kept in
|
||||
# step (CFG-03 already tracks three) and, worse, would recreate exactly
|
||||
# the two-numbers-that-disagree failure the §14 warning box describes.
|
||||
# The anti-flood cadence is a module constant for the same reason
|
||||
# freeze.RAIL_FRAC is: it describes the event bus, not the plant.
|
||||
self.clamp_wd = ClampWatchdog()
|
||||
|
||||
# P1 ingestion (TEL-01). `meter_source: off` keeps the original
|
||||
# single-entity meter_entity path, so an existing install is unchanged
|
||||
@@ -141,6 +188,11 @@ class Controller:
|
||||
self.last_write_ok = None
|
||||
self.inputs_bad_since = None
|
||||
self.dev_min = self.dev_max = None
|
||||
# SAFETY-03. What the last write's clamp did, and what the loop's own
|
||||
# bounds did last cycle. `loop_clamped` is a (engaged, note) pair so the
|
||||
# alarm can say WHICH bound bit without re-deriving it from a string.
|
||||
self.clamp_last: ClampResult | None = None
|
||||
self.loop_clamped: tuple[bool, str] = (False, "")
|
||||
self.events: list[str] = []
|
||||
self.stopping = False
|
||||
|
||||
@@ -199,11 +251,37 @@ class Controller:
|
||||
entity = self.o.get("setpoint_entity", "")
|
||||
if not entity:
|
||||
return
|
||||
# Never send a value the device will reject outright. A rejected write is
|
||||
# silent from the controller's point of view, and the inverter then keeps
|
||||
# doing whatever it was already doing.
|
||||
if self.dev_min is not None and self.dev_max is not None:
|
||||
value = max(self.dev_min, min(self.dev_max, value))
|
||||
|
||||
# --- SAFETY-03: THE CLAMP, AND IT IS ON THE ONLY PATH TO THE WIRE -----
|
||||
# Every write in this add-on comes through here - the cycle, the
|
||||
# heartbeat, the operator's stop button and shutdown() - so no optimizer,
|
||||
# maintenance or manual path can route around it. That placement is the
|
||||
# first acceptance criterion, and it is why the guard is not in
|
||||
# control.py: a guard the control law owns is a guard every other claimer
|
||||
# bypasses.
|
||||
#
|
||||
# ⚠️ A NON-FINITE VALUE IS LOSS OF INPUT, NOT AN OUT-OF-RANGE ONE. §11.1
|
||||
# rule 1: command zero and keep commanding. It must not reach the clamp
|
||||
# arithmetic - see is_commandable() for what a nan does to it - and it
|
||||
# must not be counted as a clamp engagement, or a transport bug lands in
|
||||
# the winding-loop counter.
|
||||
if not is_commandable(value):
|
||||
self.log_event(f"non-finite setpoint {value!r} - commanding 0 W")
|
||||
_LOG.error("refusing to write a non-finite setpoint %r - commanding "
|
||||
"0 W and continuing to command. This is a bug upstream, "
|
||||
"not a limit.", value)
|
||||
value = 0.0
|
||||
result = clamp_to_rating(value, float(self.o.get("max_w", 2000)),
|
||||
self.dev_min, self.dev_max)
|
||||
self.clamp_last = result
|
||||
if result.engaged:
|
||||
# ⚠️ EVERY engagement, never deduplicated: this is the action log
|
||||
# (§15), and it is a different surface from the notification, which
|
||||
# IS deduplicated. The count is what says how hard the loop pushed;
|
||||
# the notification only says that it did.
|
||||
self.log_event(result.describe())
|
||||
value = result.applied_w
|
||||
|
||||
changed = (self.last_write is None or value != self.last_write)
|
||||
if not (changed or force):
|
||||
return
|
||||
@@ -243,9 +321,18 @@ class Controller:
|
||||
standing = self.last_write if self.last_write is not None else self.target
|
||||
if self.sign_wd.evaluate(standing, self.grid, self.following, now) \
|
||||
and not was_tripped:
|
||||
# ⚠️ REASON FIRST, FLAG SECOND, and each `set` writes the file. The
|
||||
# ordering is the whole atomicity story: a crash between the two
|
||||
# persists a reason nothing reads, which is harmless, where the other
|
||||
# order persists a latch with no explanation for the operator who has
|
||||
# to decide whether to clear it.
|
||||
self.store.set("sign_reason", self.sign_wd.reason)
|
||||
self.store.set("sign_tripped", True)
|
||||
self.log_event("FAILSAFE " + self.sign_wd.reason)
|
||||
_LOG.error("SAFETY-02 TRIPPED - %s. Commanding 0 W and holding it "
|
||||
"until control is started again.", self.sign_wd.reason)
|
||||
"until control is started again. This survives an add-on "
|
||||
"restart; restarting will not clear it.",
|
||||
self.sign_wd.reason)
|
||||
|
||||
stale_after = float(self.o.get("stale_input_s", 15))
|
||||
if not self.inputs_ok and not self.sign_wd.tripped:
|
||||
@@ -340,11 +427,29 @@ class Controller:
|
||||
self.sat_count = decision.sat_count
|
||||
self.i_w = decision.i_w
|
||||
self.loop_w = decision.target_w
|
||||
# --- SAFETY-03 ---------------------------------------------------
|
||||
# ⚠️ READ THE BOOLEANS, NOT `decision.reason`. On a default install
|
||||
# the integrator bound is what bites and the output clamp is
|
||||
# unreachable (control.py says so), and `reason` is then overwritten
|
||||
# by whichever of slew-limiting or the saturation freeze ran after
|
||||
# it - so a string test is silent on the two cases a winding loop
|
||||
# most often presents as. These flags are set where the clamp
|
||||
# happens and nothing downstream touches them.
|
||||
self.loop_clamped = (
|
||||
decision.i_clamped or decision.clamped,
|
||||
(f"the loop asked for {decision.i_w:+.0f} W"
|
||||
+ (" (integrator bound)" if decision.i_clamped else "")
|
||||
+ (" (output bound)" if decision.clamped else "")),
|
||||
)
|
||||
claims.append(Claim.set("loop", P_LOOP, decision.target_w, decision.reason))
|
||||
else:
|
||||
# Stopped or blind: no accumulation may survive the outage.
|
||||
self.i_w = 0.0
|
||||
self.loop_w = None
|
||||
# A loop that is not running cannot be winding. Clearing this here
|
||||
# rather than letting the last value stand is what makes the alarm
|
||||
# de-assert when control is stopped.
|
||||
self.loop_clamped = (False, "")
|
||||
|
||||
resolution = resolve(claims)
|
||||
if resolution.contradiction:
|
||||
@@ -352,29 +457,152 @@ class Controller:
|
||||
# --- SAFETY-02's arming gate ------------------------------------------
|
||||
# Was the number about to go on the wire chosen by the grid-following
|
||||
# loop, or by a strategy that commands against the meter on purpose?
|
||||
# Only the former is expected to agree in sign with P1. See gate 1 in
|
||||
# watchdog.py - without this, every maintenance grid charge trips the
|
||||
# failsafe within three minutes of starting.
|
||||
# Only the former is expected to agree in sign with P1 - without this,
|
||||
# every maintenance grid charge trips the failsafe within three minutes.
|
||||
#
|
||||
# ⚠️ "THE LOOP WON" IS NOT ENOUGH, and the difference is a whole class of
|
||||
# false trip. A LIMIT claim can survive the loop winning and still
|
||||
# replace its number: maintenance's charge-only shaping is
|
||||
# `hi = -charge_w`, so the loop can ask for +500 W of discharge, win the
|
||||
# arbitration, and have the emitted value come out at -2500 W of grid
|
||||
# charge. Winner says "loop"; the wire carries maintenance's intent. So
|
||||
# the test is on the NUMBER, not on the name: the loop is following only
|
||||
# while the emitted value points the way the loop asked and is no larger
|
||||
# than it asked - i.e. limits reduced it, they did not redirect it.
|
||||
# Zero on either side falls out as not-following, which costs nothing:
|
||||
# a 0 W command cannot be a wrong-direction command.
|
||||
asked = self.loop_w
|
||||
self.following = (resolution.winner == "loop" and asked is not None
|
||||
and resolution.target_w * asked > 0
|
||||
and abs(resolution.target_w) <= abs(asked))
|
||||
# ⚠️ THE EXPRESSION LIVES IN watchdog.py, NOT HERE, and that is not
|
||||
# tidiness. It was inline, test_watchdog.py held a transcription of it,
|
||||
# and the P_PEAK case meant to force whoever lands peak shaving to come
|
||||
# and change an expectation did not: editing this line alone to
|
||||
# `winner in ("loop", "peak")` left every suite green while the watchdog
|
||||
# went blind for every peak event. Read loop_is_following() before
|
||||
# touching the gate - the forward hazard and the reasoning are there.
|
||||
self.following = loop_is_following(resolution, self.loop_w)
|
||||
self.target = resolution.target_w
|
||||
self.reason = resolution.explain()
|
||||
await self.write_setpoint(self.target)
|
||||
|
||||
# --- SAFETY-18, and it runs LAST on purpose --------------------------
|
||||
# Both terms of the conjunction describe the state that now exists: the
|
||||
# command that has just gone on the wire, and how long the meter that
|
||||
# chose it has been standing still. Evaluated before write_setpoint()
|
||||
# it would be reasoning about the PREVIOUS command against THIS cycle's
|
||||
# meter - the one combination that is true of neither moment.
|
||||
await self.check_output_clamp()
|
||||
await self.check_meter_frozen()
|
||||
|
||||
async def check_output_clamp(self) -> None:
|
||||
"""SAFETY-03. Alarm whenever a clamp actually engaged this cycle.
|
||||
|
||||
Runs AFTER write_setpoint() for the same reason SAFETY-18 does: the
|
||||
clamp is arithmetic done inside the write, so before the write there is
|
||||
nothing yet to report.
|
||||
|
||||
⚠️ PUBLISHING IS NOT IN THE WRITE PATH. The clamp itself is synchronous
|
||||
inside write_setpoint(); this - the awaits, the notification, anything
|
||||
that can block on Home Assistant - is out here. A stalled supervisor must
|
||||
never be able to delay or drop a frame.
|
||||
|
||||
⚠️ THIS IS NOT A TRIP. No claim is filed, nothing is latched, 0 W is not
|
||||
commanded and `publish()` still reports "running". §11.2's action for
|
||||
this row is "clamp and alarm", and the clamped value is written and the
|
||||
loop keeps running. Turning this into a trip means coming here and
|
||||
changing that deliberately, not discovering it in the field.
|
||||
"""
|
||||
engaged_write = bool(self.clamp_last and self.clamp_last.engaged)
|
||||
engaged_loop, loop_note = self.loop_clamped
|
||||
engaged = engaged_write or engaged_loop
|
||||
if engaged:
|
||||
where = (self.clamp_last.describe() if engaged_write
|
||||
else f"{CLAMP_REASON}: {loop_note}, above the "
|
||||
f"{float(self.o.get('max_w', 2000)):.0f} W rating, and "
|
||||
f"was clamped to {self.target:+.0f} W")
|
||||
reason = (f"{where}. This is a BUG SIGNAL, not a limit being used: "
|
||||
f"something upstream computed a setpoint the actuator "
|
||||
f"cannot deliver.")
|
||||
else:
|
||||
reason = ""
|
||||
fired = self.clamp_wd.note(engaged, reason, datetime.now(timezone.utc))
|
||||
|
||||
# --- THE ACTION LOG, AND IT IS COALESCED PER EPISODE ------------------
|
||||
# Every engagement is recorded, but consecutive ones are recorded by
|
||||
# UPDATING one row's count rather than inserting a row each.
|
||||
#
|
||||
# ⚠️ THAT IS NOT COSMETIC, AND IT WAS FOUND THE HARD WAY. `log_event()`
|
||||
# keeps 40 rows; a winding loop clamps on every cycle, so a row per
|
||||
# engagement flushes the whole ring within 40 cycles - and the first
|
||||
# thing it evicted, in test_freeze.py, was SAFETY-18's "METER FROZEN?"
|
||||
# row. A guard whose log drowns out the other guards' logs has moved the
|
||||
# flood rather than removed it. The count here is `clamp_wd.engagements`,
|
||||
# so nothing is lost: the row says exactly how many, and the number is
|
||||
# read off the counter rather than off the number of rows.
|
||||
#
|
||||
# This lives here rather than only in write_setpoint() because on a
|
||||
# default install the actuator-side clamp is unreachable - compute() has
|
||||
# already bounded the integrator - so the only engagements that exist are
|
||||
# loop-side ones. Measured: 60 cycles of the §10.3 runaway produce 0
|
||||
# write-path engagements and 2 loop-side ones.
|
||||
if engaged and not engaged_write:
|
||||
tag = f"{CLAMP_REASON} episode {self.clamp_wd.episodes}"
|
||||
row = (f"{tag}: {self.clamp_wd.engagements} engagement(s) - "
|
||||
f"{reason}")
|
||||
if self.events and tag in self.events[0]:
|
||||
stamp = self.events[0].split(" ", 1)[0]
|
||||
self.events[0] = f"{stamp} {row}"
|
||||
else:
|
||||
self.log_event(row)
|
||||
if not fired:
|
||||
return
|
||||
_LOG.error(
|
||||
"SAFETY-03 - %s Silently clipping this is how a winding integrator "
|
||||
"reached 14 768 W on this project before: the clamp makes every "
|
||||
"dashboard read a legal number while the thing producing it goes on "
|
||||
"climbing. The command IS clamped and the loop is STILL RUNNING - "
|
||||
"this is an alarm, not a trip. Engagements so far: %d.",
|
||||
self.clamp_wd.reason, self.clamp_wd.engagements)
|
||||
# A fixed notification_id, for the reason check_meter_frozen() gives -
|
||||
# and a DIFFERENT one from every other alarm this add-on raises, because
|
||||
# a clamp is not a frozen meter and neither is a saturation freeze.
|
||||
await self.hass.call("persistent_notification", "create", {
|
||||
"notification_id": "goodwe_output_clamp",
|
||||
"title": "GoodWe: a computed setpoint exceeded the rating",
|
||||
"message": (
|
||||
f"{self.clamp_wd.reason}\n\nThe command has been clamped and "
|
||||
f"the controller is STILL RUNNING. This is NOT the inverter "
|
||||
f"failing to follow a legal command (that is the saturation "
|
||||
f"freeze, which is normal and does not alarm) - the value asked "
|
||||
f"for was itself out of range."),
|
||||
})
|
||||
|
||||
async def check_meter_frozen(self) -> None:
|
||||
"""SAFETY-18. Alarm on a meter that answers forever without changing.
|
||||
|
||||
Notification only - no claim, no latch, no 0 W. freeze.py carries the
|
||||
reasoning and the euro figure; DOCS.md carries the exposure this does
|
||||
NOT close.
|
||||
|
||||
⚠️ getattr, not an attribute access: `unchanged_s` exists only on
|
||||
`homewizard_local`, and `p1_source` is None until amain() builds the
|
||||
transport. Every other meter_source hands the predicate None and gets
|
||||
False, which is the honest answer - see the transport note in freeze.py.
|
||||
"""
|
||||
unchanged = getattr(self.p1_source, "unchanged_s", None)
|
||||
fired = self.freeze_wd.evaluate(unchanged, self.target,
|
||||
float(self.o.get("max_w", 2000)),
|
||||
datetime.now(timezone.utc))
|
||||
if not fired:
|
||||
return
|
||||
self.log_event("METER FROZEN? " + self.freeze_wd.reason)
|
||||
_LOG.error(
|
||||
"SAFETY-18 - %s. The grid-following loop is regulating against a "
|
||||
"number that has stopped moving, and nothing in this stack stops "
|
||||
"it: the meter is still answering, so the age is fresh, the "
|
||||
"firmware watchdog is fed and the arbiter only bounds the "
|
||||
"magnitude. CHECK THE METER. Sustained for a quarter of an hour "
|
||||
"this sets the month's billed capacity-tariff peak. This is an "
|
||||
"ALARM ONLY - the loop is still running.", self.freeze_wd.reason)
|
||||
# ⚠️ A fixed notification_id, so a second episode REPLACES the first
|
||||
# rather than stacking. An operator who has to dismiss eleven identical
|
||||
# notifications learns to dismiss the twelfth without reading it.
|
||||
await self.hass.call("persistent_notification", "create", {
|
||||
"notification_id": "goodwe_meter_frozen",
|
||||
"title": "GoodWe: the P1 meter may be frozen",
|
||||
"message": (
|
||||
f"{self.freeze_wd.reason}.\n\nThe controller is STILL RUNNING "
|
||||
f"and still following this reading. Check the meter; if it is "
|
||||
f"stuck, stop control from the add-on UI."),
|
||||
})
|
||||
|
||||
# -- tasks ---------------------------------------------------------------
|
||||
async def run_control(self) -> None:
|
||||
entity = self.o.get("setpoint_entity", "")
|
||||
@@ -563,6 +791,33 @@ class Controller:
|
||||
f"{self.p1.parse_errors} rejected"
|
||||
+ (f", measurement unchanged for {unchanged:.0f} s"
|
||||
if unchanged is not None else "")})
|
||||
# SAFETY-18. Reported in both states, for the reason SAFETY-02 is:
|
||||
# a detector nobody can see is armed is a detector nobody trusts
|
||||
# when it fires. ok=False/warn=False so the banner goes red - this
|
||||
# is an alarm, and the banner is the loudest surface we own. It
|
||||
# changes NOTHING about control; see check_meter_frozen().
|
||||
if self.freeze_wd.active:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "METER MAY BE FROZEN - " + self.freeze_wd.reason
|
||||
+ ". The loop is STILL FOLLOWING it and is "
|
||||
"still running. Check the meter. Held here "
|
||||
"for a quarter of an hour this sets the "
|
||||
"month's billed capacity peak."})
|
||||
elif getattr(self.p1_source, "unchanged_s", None) is None:
|
||||
# Not "armed". Every transport but homewizard_local is invisible
|
||||
# to this check, and saying "armed" there would be a lie the
|
||||
# status page tells on behalf of a guard that cannot run.
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"freeze detector: NOT COVERED on "
|
||||
f"meter_source {o.get('meter_source')} - only "
|
||||
f"homewizard_local sees whether the meter's own "
|
||||
f"document changes"})
|
||||
else:
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"freeze detector: armed (alerts after "
|
||||
f"{self.freeze_wd.cfg.hold_s:.0f} s unchanged "
|
||||
f"while the command is over "
|
||||
f"{rail_w(self.o.get('max_w', 2000)):.0f} W)"})
|
||||
rows = [("battery SoC", self.soc, o.get("soc_entity")),
|
||||
("battery power", self.batt, o.get("batt_entity"))]
|
||||
if not self.p1_enabled:
|
||||
@@ -589,6 +844,23 @@ class Controller:
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"setpoint {sp} (range {self.dev_min:g}…{self.dev_max:g} W)"})
|
||||
|
||||
# SAFETY-03. Red while a clamp is engaged, and the engagement COUNT is
|
||||
# shown even after it clears - a loop that wound once and stopped is
|
||||
# still a bug, and a row that vanishes with the condition takes the
|
||||
# evidence with it. Reported only when there is something to report:
|
||||
# unlike the freeze detector this guard has no "not covered" state, it
|
||||
# runs on every write on every transport.
|
||||
if self.clamp_wd.active:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "OUTPUT CLAMP ENGAGED - " + self.clamp_wd.reason
|
||||
+ f" Engagements: {self.clamp_wd.engagements}."})
|
||||
elif self.clamp_wd.engagements:
|
||||
out.append({"ok": False, "warn": True,
|
||||
"text": f"output clamp: not engaged now, but it has "
|
||||
f"engaged {self.clamp_wd.engagements} time(s) in "
|
||||
f"{self.clamp_wd.episodes} episode(s) since "
|
||||
f"start - see the event log"})
|
||||
|
||||
if self.last_write_ok is False:
|
||||
out.append({"ok": False, "warn": False,
|
||||
"text": "last write to the inverter was REJECTED - check the log"})
|
||||
@@ -600,9 +872,10 @@ class Controller:
|
||||
"text": "SIGN-DISAGREEMENT FAILSAFE - " + self.sign_wd.reason
|
||||
+ ". The inverter is held at 0 W. Find out why the "
|
||||
"command opposed the meter before starting control "
|
||||
"again; starting clears this."})
|
||||
"again; starting clears this. Restarting the "
|
||||
"add-on does NOT clear it."})
|
||||
else:
|
||||
held = self.sign_wd.held_s
|
||||
held = self.sign_wd.held_s(datetime.now(timezone.utc))
|
||||
out.append({"ok": True, "warn": False,
|
||||
"text": f"sign watchdog: armed (trips after "
|
||||
f"{self.sign_wd.cfg.hold_s:.0f} s opposed, both over "
|
||||
@@ -672,6 +945,8 @@ class Controller:
|
||||
# An operator pressing start has, at minimum, looked at the
|
||||
# banner that says why.
|
||||
self.sign_wd.reset()
|
||||
self.store.set("sign_tripped", False)
|
||||
self.store.set("sign_reason", "")
|
||||
self.log_event("sign-disagreement failsafe cleared by operator")
|
||||
if not self.auto:
|
||||
self.target = 0.0
|
||||
|
||||
@@ -28,9 +28,10 @@ _LOG = logging.getLogger("goodwe.maint")
|
||||
|
||||
IDLE, DRAIN, CHARGE, HOLD = "idle", "drain", "charge", "hold"
|
||||
|
||||
# A drain of a 13.5 kWh usable pack at 2500 W is ~5 h even with no house load
|
||||
# helping. 12 h means the battery is not following commands - a fault, not a
|
||||
# slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# A drain of a 13.8 kWh usable pack (300 Ah x 51.2 V, DoD 90) at the shipped
|
||||
# 2000 W is ~6.9 h even with no house load helping - and less in practice, since
|
||||
# house load drains alongside the export and soc_floor stops short of empty.
|
||||
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
|
||||
# it is expected to span a night; 36 h still bounds it.
|
||||
DRAIN_TIMEOUT_MIN = 720
|
||||
CHARGE_TIMEOUT_MIN = 2160
|
||||
|
||||
@@ -22,11 +22,30 @@ _LOG = logging.getLogger("goodwe.store")
|
||||
# `auto_start` option only when the key is absent - if a default supplied False,
|
||||
# the fallback could never fire and auto_start would silently do nothing on
|
||||
# every fresh install.
|
||||
#
|
||||
# ⚠️ `sign_tripped` IS in here, and the difference from `auto` is the whole
|
||||
# reason both decisions are written down. `auto` has an option to fall back to
|
||||
# (`auto_start`), so a stored default would mask a fresh install. A latched
|
||||
# failsafe has no such fallback: absent means "never tripped", which is exactly
|
||||
# what a default of False says.
|
||||
#
|
||||
# It is persisted for the reason this module's docstring gives for maintenance
|
||||
# state, applied to something with a much shorter fuse. SAFETY-02's latch is the
|
||||
# only thing standing between a controller that has been caught driving the wrong
|
||||
# way and its own restart, and "restart the add-on" is the FIRST thing an operator
|
||||
# looking at a FAILSAFE banner will try. Held only in memory it came back armed,
|
||||
# into the fault, unattended - measured: after reconstructing Controller against
|
||||
# the same store, `tripped` was False, the banner read NOT READY, and it resumed
|
||||
# commanding -1000, -2000 W before re-tripping 180 s later. Under a supervisor
|
||||
# that restarts a crashed add-on that is a loop, three minutes of wrong-direction
|
||||
# power at a time, forever.
|
||||
DEFAULTS = {
|
||||
"phase": "idle",
|
||||
"phase_started": None,
|
||||
"last_completed": None,
|
||||
"last_start_attempt": None,
|
||||
"sign_tripped": False,
|
||||
"sign_reason": "",
|
||||
}
|
||||
|
||||
|
||||
@@ -42,8 +61,10 @@ class Store:
|
||||
loaded = json.load(fh)
|
||||
if isinstance(loaded, dict):
|
||||
self.data = {**DEFAULTS, **loaded}
|
||||
_LOG.info("state restored: phase=%s last_completed=%s",
|
||||
self.data.get("phase"), self.data.get("last_completed"))
|
||||
_LOG.info("state restored: phase=%s last_completed=%s "
|
||||
"sign_tripped=%s",
|
||||
self.data.get("phase"), self.data.get("last_completed"),
|
||||
self.data.get("sign_tripped"))
|
||||
except FileNotFoundError:
|
||||
_LOG.info("no saved state, starting fresh")
|
||||
except (json.JSONDecodeError, OSError) as err:
|
||||
|
||||
@@ -85,6 +85,37 @@ NOT READY banner already names the problem, (b) does not apply.
|
||||
watchdog: armed". A disarmed guard that advertises itself as armed is the
|
||||
one thing this project has decided repeatedly it will not ship.
|
||||
|
||||
6. `maintenance_charge_w` above `max_w`. [(a)]
|
||||
The same shape as 5, and found the same way - by checking a worked example
|
||||
against what actually ships. maintenance's cheap-window shaping files
|
||||
`Claim.limit(hi=-maintenance_charge_w)` at P_MAINT_SHAPE, against the
|
||||
`supervised` SAFETY limit's `lo=-max_w`. Both bind (P_SAFETY and
|
||||
P_MAINT_SHAPE both outrank the loop that wins the SET), so a charge rate
|
||||
above the ceiling gives `lo > hi` - the arbiter's clause 3, which it
|
||||
correctly resolves to 0 W and logs as a CONTRADICTION. Measured against
|
||||
the arbiter, loop asking +500 W:
|
||||
|
||||
max_w=2000 hi=-2500 -> +0 W contradiction=True
|
||||
max_w=2500 hi=-2500 -> -2500 W limited by supervised(max_w)
|
||||
max_w=3000 hi=-2500 -> -2500 W limited by maintenance(...)
|
||||
|
||||
So MAINTENANCE SILENTLY NEVER CHARGES IN A CHEAP WINDOW until max_w is at
|
||||
or above the charge rate, and the only evidence is a contradiction line
|
||||
that reads like a bug in the arbiter rather than like the two numbers the
|
||||
operator set. Equality is fine and deliberately not refused - at
|
||||
max_w == charge_w the window is a single reachable point, -max_w.
|
||||
|
||||
⚠️ `maintenance_discharge_w` IS NOT THE SAME CASE, and this was checked
|
||||
rather than assumed. THE SHAPING IS NOT SYMMETRIC: the drain phase does
|
||||
not shape the loop, it OWNS the actuator - `Claim.set(P_MAINTENANCE,
|
||||
+discharge_w)`. A SET is clamped by the limits above it, not contradicted
|
||||
by them, so 2500 against a 2000 W ceiling emits +2000 W and the arbiter's
|
||||
own explain() says `maintenance -> 2000 W, limited by supervised(max_w)`
|
||||
on the status page every cycle. That is neither (a) - nothing is silent -
|
||||
nor (b) - it moves energy and the cycle still completes, just slower
|
||||
(13.8 kWh usable at 2000 W is ~6.9 h against the 720 min DRAIN_TIMEOUT).
|
||||
It is warned about below, not refused.
|
||||
|
||||
WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
|
||||
- `integrator_max_w` above `max_w`. DOCS.md is right that the only thing the
|
||||
@@ -102,6 +133,9 @@ WHAT IS DELIBERATELY *NOT* REFUSED, because it is untidy rather than unsafe:
|
||||
NOT READY banner.
|
||||
- `meter_poll_s` above half `meter_max_age_s`. One missed poll costs a stale
|
||||
reading and a 0 W cycle. Warned about in p1.py, not refused.
|
||||
- `maintenance_discharge_w` above `max_w`. Clamped, not contradicted, and the
|
||||
clamp names itself in the arbiter's explain() - see rule 6. Warned about,
|
||||
not refused.
|
||||
"""
|
||||
|
||||
import logging
|
||||
@@ -269,6 +303,52 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
f"sign_disagree_w below {max_w:.0f} W (300 W is the measured "
|
||||
"default), or raise max_w.")
|
||||
|
||||
# --- 6. a maintenance charge the ceiling can actually accommodate --------
|
||||
# ⚠️ Strictly `>`, matching the arbiter exactly. The shaping is
|
||||
# `Claim.limit(hi=-charge_w)` against `supervised`'s `lo=-max_w`, so
|
||||
# charge_w == max_w leaves the single reachable point -max_w and works;
|
||||
# only ABOVE is `lo > hi`, arbiter clause 3, 0 W and a contradiction.
|
||||
#
|
||||
# Not scoped to maintenance_enabled, deliberately. The pair is
|
||||
# contradictory whether or not the schedule is on, and scoping it would
|
||||
# leave the trap armed for the one operator action - ticking
|
||||
# maintenance_enabled - that cannot possibly be expected to change what a
|
||||
# charge rate means.
|
||||
# ⚠️ THE FALLBACK IS config.yaml's SHIPPED VALUE, and it has to be kept
|
||||
# equal to it - that is the whole point of AC3. It is reachable only when a
|
||||
# caller hands over a dict with the key missing (sim/inject.py, a test); the
|
||||
# Supervisor always supplies every key from config.yaml, so on a real
|
||||
# install the argument is always present.
|
||||
#
|
||||
# ⚠️ KNOWN MISMATCH, LEFT DELIBERATELY AND FLAGGED RATHER THAN FIXED HERE:
|
||||
# `main.py` still falls back to 2500 in two places
|
||||
# (`opts.get("maintenance_charge_w", 2500)`), as does maintenance.py's
|
||||
# MaintConfig dataclass. So a dict with the key ABSENT is accepted by this
|
||||
# rule at 2000 and then built by main.py at 2500 - the contradiction this
|
||||
# rule exists to catch, in the one case it cannot see. It is unreachable on
|
||||
# a Supervisor install and those files are another ticket's right now.
|
||||
# THE REAL FIX is one source of truth for option defaults; until then the
|
||||
# divergence is PINNED BY A CHECK rather than by this comment - see
|
||||
# test_validate.py, "the KNOWN cross-file default divergence". It asserts
|
||||
# the mismatch as it stands and goes red if EITHER side moves, including
|
||||
# when somebody closes it in main.py, at which point this block and that
|
||||
# check both get deleted.
|
||||
charge_w = _number(opts, "maintenance_charge_w", 2000.0)
|
||||
if charge_w is None:
|
||||
problems.append(
|
||||
f"maintenance_charge_w {opts.get('maintenance_charge_w')!r} is not a number")
|
||||
elif max_w is not None and max_w > 0 and charge_w > max_w:
|
||||
problems.append(
|
||||
f"maintenance_charge_w is {charge_w:.0f} W but max_w is "
|
||||
f"{max_w:.0f} W, so a maintenance charge in a cheap window can "
|
||||
"never happen: the shaping asks the arbiter for at most "
|
||||
f"{-charge_w:.0f} W while the supervised limit allows no less than "
|
||||
f"{-max_w:.0f} W, which is a contradiction it resolves to 0 W - "
|
||||
"THE CEILING WINS, and what you would see is an ARBITER "
|
||||
"CONTRADICTION line that reads like a bug rather than like these "
|
||||
f"two numbers. Lower maintenance_charge_w to {max_w:.0f} W or less, "
|
||||
f"or raise max_w to at least {charge_w:.0f} W.")
|
||||
|
||||
# --- warnings: real, but not worth refusing over -------------------------
|
||||
integ = opts.get("integrator_max_w")
|
||||
integ_w = None if not integ else _number(opts, "integrator_max_w", None)
|
||||
@@ -280,6 +360,25 @@ def validate_startup_config(opts: dict, dev_min=None, dev_max=None) -> list[str]
|
||||
"saturation. 0 (follow max_w) is the recommended value.",
|
||||
integ_w, max_w)
|
||||
|
||||
# ⚠️ THE SIBLING OF RULE 6, AND NOT THE SAME CASE - see the docstring. The
|
||||
# drain phase OWNS the actuator (`Claim.set` at P_MAINTENANCE), and a SET is
|
||||
# clamped by the limits above it rather than contradicted by them. So this
|
||||
# drains at max_w instead of the configured rate, the arbiter says so in
|
||||
# words on the status page every cycle, and the cycle still completes -
|
||||
# slower, and eating into maintenance.DRAIN_TIMEOUT_MIN. Loud and it moves
|
||||
# energy, so it is neither (a) nor (b): warned, not refused.
|
||||
disch_w = _number(opts, "maintenance_discharge_w", 2000.0)
|
||||
if disch_w is not None and max_w is not None and max_w > 0 and disch_w > max_w:
|
||||
_LOG.warning(
|
||||
"maintenance_discharge_w %.0f W is above max_w %.0f W. Not refused - "
|
||||
"the drain phase SETS the setpoint and the arbiter clamps it to "
|
||||
"%.0f W and names the clamp ('limited by supervised(max_w)'), so "
|
||||
"nothing is silent and the cycle still completes. But it drains at "
|
||||
"%.0f W, not the %.0f W you configured, and the drain phase has a "
|
||||
"720 min timeout. Lower it to %.0f W or raise max_w to remove the "
|
||||
"surprise.",
|
||||
disch_w, max_w, max_w, max_w, disch_w, max_w)
|
||||
|
||||
return problems
|
||||
|
||||
|
||||
|
||||
@@ -18,15 +18,36 @@ module over both of them. Every number in this file was measured on those two
|
||||
days, not chosen:
|
||||
|
||||
day samples gated in sign agreement
|
||||
2026-08-23 4 127 / 16 349 92.9 % (healthy)
|
||||
2026-08-20 6 892 / 15 598 55.6 % (the whole fault day)
|
||||
episode A 15:26-16:43 0.3 %
|
||||
episode B 17:11-18:28 0.8 %
|
||||
episode C 20:01-20:31 11.0 %
|
||||
episode D 20:55-21:11 0.0 %
|
||||
2026-08-23 4 212 / 17 280 93.4 % (healthy)
|
||||
2026-08-20 7 182 / 17 280 56.4 % (the whole fault day)
|
||||
cluster A 15:26-16:43 0.3 %
|
||||
cluster B 17:11-18:28 0.9 %
|
||||
cluster C 20:01-20:31 10.5 %
|
||||
cluster D 20:55-21:11 0.0 %
|
||||
|
||||
That is the signature, and it is the SAME signature in all four episodes: not a
|
||||
noisier version of healthy, a near-total inversion.
|
||||
⚠️ THOSE AGREEMENT FIGURES ARE THE WEAKEST EVIDENCE ON THIS PAGE, and an earlier
|
||||
version of this comment leaned on them as though they were the strongest. The
|
||||
clusters are found by looking for sustained opposed samples, so measuring "how
|
||||
opposed is this cluster" over them is close to a tautology - and "the healthy day
|
||||
contains no such cluster" is the same sentence as "the healthy day produces no
|
||||
trip", not independent corroboration of it.
|
||||
|
||||
What actually carries the argument is two things neither the detector nor the
|
||||
clustering assumes:
|
||||
|
||||
1. The RUN-LENGTH DISTRIBUTION. The longest unbroken opposed run on the healthy
|
||||
day is 30 s. On the fault day there are 18 runs over 180 s and the longest is
|
||||
1750 s. Nothing about that gap was chosen - it is what the two days measure.
|
||||
2. The clusters land where a human independently wrote down onsets. NOTES.md
|
||||
§4.7 records 15:01, 16:56, 19:57 and 20:23 from watching it happen, before
|
||||
any of this existed, and cluster D coincides with the separately documented
|
||||
inverter-off runaway of §4.7 item 2.
|
||||
|
||||
Be precise about (2), because the convenient overstatement is available and wrong:
|
||||
the clustering does NOT reproduce four episodes. It yields THREE clusters over the
|
||||
four documented onsets - C spans both 19:57 and 20:23 - plus a fourth for §4.7
|
||||
item 2, which is not one of the four. Every trip does fall inside a documented
|
||||
window, which is the claim worth making.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY IT LIVES HERE AND NOT IN THE FIRMWARE OR THE WITNESS
|
||||
@@ -68,21 +89,31 @@ Four gates, and each one exists to exclude a specific thing that is NOT a fault:
|
||||
1. `following`. ⚠️ THE GATE THAT IS EASIEST TO FORGET AND MOST EXPENSIVE TO
|
||||
OMIT. Sign agreement is a property of a GRID-FOLLOWING loop. It is not
|
||||
expected of a strategy that deliberately commands against the meter -
|
||||
maintenance is exactly that. A maintenance grid charge of 2500 W into a house
|
||||
drawing 500 W puts +3000 W on the meter against a -2500 W command: opposed,
|
||||
maintenance is exactly that. A maintenance grid charge of 1500 W into a house
|
||||
drawing 500 W puts +2000 W on the meter against a -1500 W command: opposed,
|
||||
both far over any sane threshold, and sustained for HOURS. Armed
|
||||
unconditionally this watchdog would trip on every single maintenance cycle,
|
||||
which is not a tuning problem, it is the wrong question being asked. So the
|
||||
caller says whether the grid-following loop actually won the arbitration this
|
||||
cycle, and the timer only accumulates when it did.
|
||||
|
||||
⚠️ 1500 W, NOT THE DEFAULT 2500 W, AND THE REASON IS NOT COSMETIC. At the
|
||||
shipped defaults `maintenance_charge_w` is 2500 and `max_w` is 2000, so the
|
||||
cheap-window claim is `hi = -2500` against a supervised `lo = -2000`: lo > hi,
|
||||
which arbiter.py resolves as a CONTRADICTION and 0 W, not as a -2500 W charge.
|
||||
The example above is written at 1500 W because that is a combination the
|
||||
schema and the arbiter both actually produce. (The contradiction at the
|
||||
defaults is a real pre-existing bug - a default maintenance charge silently
|
||||
never happens in a cheap window - but it is maintenance's, not this module's,
|
||||
and it is filed separately. Do not "fix" it here.)
|
||||
|
||||
2. The strict `< 0` product. "Opposed" and "neither side is zero" in one
|
||||
expression.
|
||||
|
||||
3. The 300 W magnitude gate ON BOTH SIDES. Near zero the sign is noise, and near
|
||||
zero is where a healthy loop LIVES - the deadband holds the command still
|
||||
while the meter wanders either side of `target_grid_w`. On the healthy day
|
||||
only 4 127 of 16 349 samples (25 %) are even gated in; the other 75 % are the
|
||||
only 4 212 of 17 280 samples (24 %) are even gated in; the other 76 % are the
|
||||
converged band where sign carries no information. This is also why the
|
||||
deadband cannot produce a false trip: inside it the meter is by definition
|
||||
under 300 W.
|
||||
@@ -109,6 +140,33 @@ a stuck reading of +800 W makes the loop command discharge and keep commanding
|
||||
discharge. Command and meter converge on AGREEING. Freezes are SAFETY-12's and
|
||||
SAFETY-01's problem, and this watchdog neither helps nor hinders there.
|
||||
|
||||
⚠️ ALL OF THAT DEPENDS ON ONE PROPERTY OF THE CONTROL LAW, so it is an invariant
|
||||
and not a happy accident: the saturation freeze in control.py must keep letting
|
||||
the command FALL, CROSS ZERO AND REVERSE - "may not wind further in the direction
|
||||
it is already pushing", not "only corrections that shrink |i_w|". control.py
|
||||
records the shrink-only encoding as tried and rejected because it pins the command
|
||||
at its last value indefinitely; a pinned command against a meter that has moved on
|
||||
is precisely a sustained sign disagreement, so under that encoding this watchdog
|
||||
WOULD false-trip on a plain load step. If anyone ever revisits that freeze, this
|
||||
module's no-false-positive argument is downstream of the answer.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT IT DOES NOT CATCH
|
||||
|
||||
An inverter that ACTS opposite to what it was told. Tell it to discharge 2000 W
|
||||
and have it charge instead, and the meter moves FURTHER the way it was already
|
||||
going - so the command and the meter agree, all the way into the rail. This
|
||||
watchdog compares the loop's output direction against the input state it was
|
||||
regulating; it is blind to the plant lying about which way it went. That is the
|
||||
saturation freeze's question (|command - the battery's actual power| > 500 W,
|
||||
NOTES.md §4.7 row 4), and the two checks are complementary rather than
|
||||
overlapping. Neither substitutes for the other.
|
||||
|
||||
Nor does it see a sign inversion introduced DOWNSTREAM of this add-on - in the
|
||||
firmware, on the wire, or in a future driver. Our view stays self-consistent and
|
||||
this stays silent. That is a wire-versus-intent problem and it belongs to the
|
||||
witness, which is the only vantage point that sees both.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
STATE, TRIP AND LATCH
|
||||
|
||||
@@ -123,6 +181,15 @@ hand the actuator straight back to the loop that was driving the wrong way -
|
||||
three minutes later, forever. `tripped` therefore stays true until an operator
|
||||
`reset()`s it by starting control again, which is a deliberate human act after
|
||||
looking at why.
|
||||
|
||||
⚠️ AND THE LATCH HAS TO OUTLIVE THE PROCESS. Held only in memory it is not a
|
||||
latch at all - a container restart clears it and the add-on comes back armed,
|
||||
into the same fault, unattended. Worse than merely losing state: "restart the
|
||||
add-on" is the first thing an operator confronted with a FAILSAFE banner and a
|
||||
0 W inverter will try, and under a supervisor that restarts a crashed add-on it
|
||||
is a loop of three-minute wrong-direction bursts. `tripped` and `reason` are
|
||||
therefore constructor arguments, restored from `Store` in `Controller.__init__`
|
||||
and written back the moment the trip happens. See store.py.
|
||||
"""
|
||||
|
||||
from dataclasses import dataclass
|
||||
@@ -137,6 +204,71 @@ class SignWatchdogConfig:
|
||||
hold_s: float = 180.0
|
||||
|
||||
|
||||
def disagrees(commanded_w, grid_w, following: bool,
|
||||
cfg: SignWatchdogConfig) -> bool:
|
||||
"""The predicate, and the ONLY place it is written down.
|
||||
|
||||
⚠️ Public because `sim/replay_sign.py` needs it too - to describe episodes, to
|
||||
measure agreement, to sweep the clock-skew guard - and it had reimplemented it
|
||||
inline. Two copies of a safety predicate is one copy plus a future
|
||||
disagreement about what the check means, and the copy that drifts is always
|
||||
the one in the harness that grades it.
|
||||
"""
|
||||
return (following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w)
|
||||
|
||||
|
||||
def loop_is_following(resolution, loop_asked) -> bool:
|
||||
"""Did the grid-following loop actually choose the number going on the wire?
|
||||
|
||||
Gate 1 of the predicate above, and it lives here rather than inline in
|
||||
`cycle()` for the reason `disagrees()` does: the test suite has to be able to
|
||||
assert on THE SHIPPED EXPRESSION, not on a transcription of it that drifts
|
||||
apart from it in silence.
|
||||
|
||||
⚠️ IT WAS A TRANSCRIPTION, AND THAT WAS MEASURED, NOT FEARED. The P_PEAK case
|
||||
in test_watchdog.py exists to make whoever lands peak shaving come here and
|
||||
change an expectation. With the expression copied into the test it did not do
|
||||
that: editing the shipped gate alone to `winner in ("loop", "peak")` left every
|
||||
suite green while the watchdog went blind for the whole of every peak event.
|
||||
One definition, two callers, and that test now bites.
|
||||
|
||||
`resolution` the arbiter's Resolution. Duck-typed on `.winner` and
|
||||
`.target_w` so this module still imports nothing from arbiter.
|
||||
`loop_asked` what the grid-following loop claimed this cycle, or None if it
|
||||
did not claim at all.
|
||||
|
||||
"The loop won" is NOT the question, and the difference is a whole class of
|
||||
false trip. A LIMIT claim can survive the loop winning and still replace its
|
||||
number: maintenance's cheap-window shaping is `hi = -maintenance_charge_w`, so
|
||||
at 1500 W the loop can ask for +500 W of discharge, win the arbitration, and
|
||||
have the emitted value come out at -1500 W of grid charge. Winner says "loop";
|
||||
the wire carries maintenance's intent.
|
||||
|
||||
So the test is on the NUMBER: the loop is following only while the emitted
|
||||
value points the way the loop asked AND is no larger than it asked - limits
|
||||
reduced it, they did not redirect it. The magnitude half is load-bearing on
|
||||
its own, because a `lo` limit can raise magnitude without flipping sign, and
|
||||
that is not the loop following either. Zero on either side falls out as
|
||||
not-following, which costs nothing: a 0 W command cannot be a
|
||||
wrong-direction command.
|
||||
|
||||
⚠️ FORWARD HAZARD, and the claim block in cycle() already anticipates it.
|
||||
`winner == "loop"` disarms the watchdog under ANY higher-priority SET claim.
|
||||
Today only maintenance and the safety stops emit one and neither follows the
|
||||
meter, so the gate costs nothing. A peak-shaving strategy claiming SET at
|
||||
P_PEAK **is** grid-following in sign, and the moment it lands this goes blind
|
||||
for the duration of every peak event. Widening it means asking "does the
|
||||
winning strategy follow the meter", not adding another name to a comparison.
|
||||
"""
|
||||
return (resolution.winner == "loop" and loop_asked is not None
|
||||
and resolution.target_w * loop_asked > 0
|
||||
and abs(resolution.target_w) <= abs(loop_asked))
|
||||
|
||||
|
||||
class SignWatchdog:
|
||||
"""One instance per actuator, evaluated once per control cycle.
|
||||
|
||||
@@ -147,11 +279,16 @@ class SignWatchdog:
|
||||
arbiter applies to the actuator, applied to the detector's own state.
|
||||
"""
|
||||
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None):
|
||||
def __init__(self, cfg: SignWatchdogConfig | None = None, *,
|
||||
tripped: bool = False, reason: str = ""):
|
||||
self.cfg = cfg or SignWatchdogConfig()
|
||||
self.disagree_since: datetime | None = None
|
||||
self.tripped = False
|
||||
self.reason = ""
|
||||
# ⚠️ RESTORED FROM THE STORE, NOT DEFAULTED. A latch that lives only in
|
||||
# memory is not a latch: a container restart clears it, and the add-on
|
||||
# comes back armed, into the same fault, with no operator involved. See
|
||||
# store.py's note on `sign_tripped` for the measured behaviour.
|
||||
self.tripped = bool(tripped)
|
||||
self.reason = reason if self.tripped else ""
|
||||
|
||||
# -- the whole check, and it is a pure function of its arguments ----------
|
||||
def evaluate(self, commanded_w, grid_w, following: bool,
|
||||
@@ -178,15 +315,7 @@ class SignWatchdog:
|
||||
return True
|
||||
|
||||
cfg = self.cfg
|
||||
disagree = (
|
||||
following
|
||||
and commanded_w is not None and grid_w is not None
|
||||
and commanded_w * grid_w < 0
|
||||
and abs(commanded_w) > cfg.min_w
|
||||
and abs(grid_w) > cfg.min_w
|
||||
)
|
||||
|
||||
if not disagree:
|
||||
if not disagrees(commanded_w, grid_w, following, cfg):
|
||||
self.disagree_since = None
|
||||
return False
|
||||
|
||||
@@ -206,13 +335,18 @@ class SignWatchdog:
|
||||
)
|
||||
return True
|
||||
|
||||
@property
|
||||
def held_s(self) -> float:
|
||||
"""How long the current disagreement has been standing, for the UI."""
|
||||
def held_s(self, now: datetime) -> float:
|
||||
"""How long the current disagreement has been standing, for the UI.
|
||||
|
||||
⚠️ Takes the clock rather than reading one. It was a property calling
|
||||
`datetime.now()`, which quietly broke the property this module's header
|
||||
advertises - every other observable here is a pure function of what it
|
||||
was handed - and an unclocked function is one nothing can test, which is
|
||||
exactly what happened to it.
|
||||
"""
|
||||
if self.disagree_since is None:
|
||||
return 0.0
|
||||
return (datetime.now(self.disagree_since.tzinfo)
|
||||
- self.disagree_since).total_seconds()
|
||||
return (now - self.disagree_since).total_seconds()
|
||||
|
||||
def reset(self) -> None:
|
||||
self.disagree_since = None
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: GoodWe RS485 Controller
|
||||
version: "0.5.0"
|
||||
version: "0.5.2"
|
||||
slug: goodwe_controller
|
||||
description: >-
|
||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||
@@ -101,7 +101,7 @@ options:
|
||||
# Both defaults are measured, not chosen. On the captured healthy day
|
||||
# (2026-08-23) the longest legitimate opposed run - a load step the loop has
|
||||
# not caught up with - is 30 s, and sign agreement over the gated samples is
|
||||
# 92.9 %. On the captured fault day (2026-08-20) the four episodes run 0.0-11 %
|
||||
# 93.4 %. On the captured fault day (2026-08-20) the clusters run 0.0-10.5 %
|
||||
# agreement with opposed runs up to 1752 s. 300 W / 180 s sits in the middle of
|
||||
# a very wide gap: at 60 s the healthy day still trips nothing, at 300 s the
|
||||
# fault day still trips 13 times. There is no reason to move either number
|
||||
@@ -114,12 +114,47 @@ options:
|
||||
sign_disagree_w: 300
|
||||
sign_disagree_s: 180
|
||||
|
||||
# --- SAFETY-18 frozen-but-fresh meter detector -----------------------------
|
||||
# Seconds the meter may keep answering with an UNCHANGED measurement while the
|
||||
# command stands at the rail before the add-on raises an alarm. Both halves
|
||||
# are required: neither one alone is safe, and app/freeze.py carries why.
|
||||
#
|
||||
# ALARM ONLY. It does not command 0 W and does not latch. A false trip parks
|
||||
# the battery; a false notification costs an alert.
|
||||
#
|
||||
# ⚠️ Only `meter_source: homewizard_local` can see this at all - it is the
|
||||
# only transport that reads the meter's own document. On every other source
|
||||
# the status page says NOT COVERED rather than "armed".
|
||||
#
|
||||
# 300 s is measured, not chosen. Over 2399 s of the live house at the
|
||||
# converged operating point (sim/scenarios/p1-age-2026-08-26.jsonl.gz, mean
|
||||
# grid -14.2 W, 1194 polls, 735 of them repeating the previous reading) the
|
||||
# LONGEST run without a distinct reading is 15.4 s (the largest unchanged_s any
|
||||
# sample observes is 8.0 s). 300 s is 19.5x the pessimistic figure, and
|
||||
# still inside the 900 s quarter that bills the capacity tariff.
|
||||
meter_freeze_s: 300
|
||||
|
||||
# --- maintenance -----------------------------------------------------------
|
||||
maintenance_enabled: false
|
||||
maintenance_interval_days: 28
|
||||
maintenance_start_hour: 10
|
||||
maintenance_discharge_w: 2500
|
||||
maintenance_charge_w: 2500
|
||||
# ⚠️ BOTH MUST STAY AT OR BELOW max_w, and that is why they are 2000 rather
|
||||
# than the 2500 they shipped as. The cheap-window charge shaping asks the
|
||||
# arbiter for `hi = -maintenance_charge_w` against the supervised `lo =
|
||||
# -max_w`: above the ceiling that is `lo > hi`, a contradiction resolved to
|
||||
# 0 W, so maintenance would SILENTLY NEVER CHARGE in a cheap window on a
|
||||
# default install. validate.py refuses that config (rule 6), so these
|
||||
# defaults had to become self-consistent with the max_w above rather than
|
||||
# ship a configuration the validator rejects.
|
||||
#
|
||||
# The discharge side is clamped rather than contradicted - it drains at max_w
|
||||
# and the arbiter says so - so it is only warned about; it is 2000 here for
|
||||
# symmetry and to keep the shipped config warning-free.
|
||||
#
|
||||
# Raising max_w (the live reference install runs 5000) is what unlocks a
|
||||
# faster maintenance cycle. Raise max_w FIRST, then these.
|
||||
maintenance_discharge_w: 2000
|
||||
maintenance_charge_w: 2000
|
||||
maintenance_soc_floor: 11
|
||||
maintenance_soc_target: 99
|
||||
maintenance_hold_min: 120
|
||||
@@ -181,6 +216,15 @@ schema:
|
||||
sign_disagree_w: int(50,5000)
|
||||
sign_disagree_s: int(30,1800)
|
||||
|
||||
# No "off" value, for SAFETY-02's reason: disarming a safety alarm is not a
|
||||
# supported configuration. ⚠️ THE FLOOR OF 60 IS NOT A RECOMMENDATION. At 300 s
|
||||
# the slowest a HEALTHY meter's 1 Wh register can tick and still look unchanged
|
||||
# is 12 W, which is inside the 15 W deadband, so the two terms of the
|
||||
# conjunction are mutually exclusive rather than merely far apart. At 60 s that
|
||||
# figure is 60 W and the argument is gone - only the margin is left. See
|
||||
# app/freeze.py.
|
||||
meter_freeze_s: int(60,3600)
|
||||
|
||||
maintenance_enabled: bool
|
||||
maintenance_interval_days: int(1,90)
|
||||
maintenance_start_hour: int(0,23)
|
||||
|
||||
Binary file not shown.
@@ -0,0 +1,550 @@
|
||||
"""Runnable check for SAFETY-03, the output clamp and its winding-loop alarm.
|
||||
|
||||
python3 test_clamp.py
|
||||
|
||||
No framework, asserts only, same house style as test_freeze.py.
|
||||
|
||||
Five parts, and parts 3 and 4 are the ones that carry the acceptance criteria:
|
||||
|
||||
1. THE CLAMP ARITHMETIC, on the shipped `clamp_to_rating()` - boundaries,
|
||||
symmetry, the device second stage, and the non-finite cases. Table driven.
|
||||
2. THE ALARM'S CADENCE - rising edge, re-assert, hysteresis - on the shipped
|
||||
`ClampWatchdog`. Every engagement counted, notifications not flooded.
|
||||
3. AC 1 + AC 3, WIRED. A computed setpoint that exceeds the rating, driven
|
||||
through the REAL `Controller.cycle()`: nothing over the rating reaches the
|
||||
device, and the alarm fires. Includes the historical runaway from
|
||||
specs.md 10.3 replayed against an unclamped transcription, so the check
|
||||
says what the clamp is actually worth in watts rather than asserting a
|
||||
constant.
|
||||
4. AC 2, AND IT IS THE LOAD-BEARING HALF. A loop that SATURATES WITHOUT
|
||||
CLAMPING - the inverter refusing to follow a perfectly legal command - must
|
||||
raise NO clamp alarm. If it does, the bug signal is inside the noise again
|
||||
and the whole ticket has bought nothing.
|
||||
5. NO PATH BYPASSES IT. write_setpoint() is the only route to the wire, so it
|
||||
is called directly with an out-of-range value the way the heartbeat and the
|
||||
operator's buttons call it.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHY PART 4 ALSO ASSERTS ON `Decision`'s BOOLEANS AND NOT ON `reason`
|
||||
|
||||
`Decision.reason` is one string and the stages after the clamp overwrite it. The
|
||||
check below drives a cycle that clamps the integrator AND is then slew limited,
|
||||
and asserts that `reason` does NOT say so while `i_clamped` does. That is not a
|
||||
style preference - an alarm keyed on the string is silent on exactly the cycles a
|
||||
winding loop produces, and this is the check that would go red if someone
|
||||
"simplified" main.py back onto it.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
WHAT THIS CHECK DOES NOT COVER
|
||||
|
||||
- The firmware-side magnitude clamp (the card's "two clamps, not one"). This
|
||||
add-on's `write_setpoint()` is the add-on half; the ESP32 half is DRIVER-07's
|
||||
and is not in this repo's Python.
|
||||
- A rig run. Nothing here needs one: the clamp is arithmetic on the write path
|
||||
and part 3 drives the shipped `Controller.cycle()` against a stub Home
|
||||
Assistant, which is the same surface test_freeze.py part 1-2 use. The wire-
|
||||
level invariant the card asks for (`|emitted| <= rating` on every frame) is
|
||||
asserted here over every value that reached `set_number()`, which is the last
|
||||
thing this process controls; proving it at the inverter needs the witness log
|
||||
and belongs with DRIVER-07.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import math
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.clamp import (
|
||||
CLEAR_CYCLES, REASON_CODE, REASSERT_S, ClampWatchdog, clamp_to_rating,
|
||||
is_commandable,
|
||||
)
|
||||
from app.control import Tuning, compute
|
||||
from app.main import Controller
|
||||
|
||||
fails = []
|
||||
T0 = datetime(2026, 8, 30, 9, 0, 0, tzinfo=timezone.utc)
|
||||
|
||||
# The live install's numbers. NOTES.md and freeze.py both say max_w: 5000 there,
|
||||
# which is also the device rating, so this is the bound the alarm is written at.
|
||||
LIVE_MAX_W = 5000.0
|
||||
CLAMP_ID = "goodwe_output_clamp"
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print("1. the clamp arithmetic, on the shipped expression")
|
||||
|
||||
# (requested, limit, expected applied, expected engaged, expected bound)
|
||||
TABLE = [
|
||||
(5001.0, 5000.0, 5000.0, True, "max_w"), # +limit+1
|
||||
(-5001.0, 5000.0, -5000.0, True, "max_w"), # -limit-1, the export side
|
||||
(5000.0, 5000.0, 5000.0, False, ""), # exactly +limit: NOT engaged
|
||||
(-5000.0, 5000.0, -5000.0, False, ""), # exactly -limit: NOT engaged
|
||||
(0.0, 5000.0, 0.0, False, ""), # the failsafe value
|
||||
(1234.0, 5000.0, 1234.0, False, ""),
|
||||
(14768.0, 5000.0, 5000.0, True, "max_w"), # 10.3's reported runaway
|
||||
]
|
||||
for requested, limit, want_applied, want_engaged, want_bound in TABLE:
|
||||
r = clamp_to_rating(requested, limit)
|
||||
check(f"{requested:+.0f} W against a {limit:.0f} W rating -> "
|
||||
f"{r.applied_w:+.0f} W, engaged={r.engaged}, bound={r.bound!r}",
|
||||
r.applied_w == want_applied and r.engaged is want_engaged
|
||||
and r.bound == want_bound)
|
||||
|
||||
# It is a MAGNITUDE clamp (3.2), so import and export must be bound identically.
|
||||
# Derived over a sweep rather than asserted on two hand-picked values.
|
||||
asym = [m for m in range(0, 12001, 37)
|
||||
if clamp_to_rating(m, LIVE_MAX_W).applied_w
|
||||
!= -clamp_to_rating(-m, LIVE_MAX_W).applied_w]
|
||||
check(f"symmetric over {len(range(0, 12001, 37))} magnitudes "
|
||||
f"({len(asym)} asymmetric)", not asym)
|
||||
|
||||
# The engagement flag has to mean "the RAW value differed", which is the words
|
||||
# AC 2 uses. Re-derived from the result's own fields, not from the table.
|
||||
mismatch = [m for m in range(0, 12001, 37)
|
||||
for r in [clamp_to_rating(m, LIVE_MAX_W)]
|
||||
if r.engaged != (r.requested_w != r.applied_w)]
|
||||
check("engaged is exactly 'raw differs from applied', over the same sweep",
|
||||
not mismatch)
|
||||
|
||||
# The device second stage. Only reachable when max_w is ABOVE the device range,
|
||||
# i.e. when validate_startup_config() did not run or no longer holds.
|
||||
r = clamp_to_rating(3000.0, 5000.0, dev_min=-2000.0, dev_max=2000.0)
|
||||
check(f"a device narrower than max_w still bites, and says which bound "
|
||||
f"({r.applied_w:+.0f} W, {r.bound!r})",
|
||||
r.applied_w == 2000.0 and r.engaged and r.bound == "device")
|
||||
r = clamp_to_rating(3000.0, 5000.0, dev_min=-5000.0, dev_max=5000.0)
|
||||
check("...and is a no-op once the startup validation holds",
|
||||
r.applied_w == 3000.0 and not r.engaged)
|
||||
|
||||
# ⚠️ REGRESSION, REVIEW-FOUND. THE FIRST STAGE USED TO `return` AND THE DEVICE
|
||||
# STAGE WAS THEN NEVER REACHED, so the harder the overshoot the less the guard
|
||||
# did: at max_w 5000 against a +-4000 device, +9999 emitted +5000 - OUTSIDE THE
|
||||
# DEVICE RANGE - while a mere +4500 was correctly held to +4000. That inverts
|
||||
# the guard and it was a regression against the pre-PR `write_setpoint()`, whose
|
||||
# comment read "never send a value the device will reject outright".
|
||||
#
|
||||
# The property is asserted over a sweep, not on the two witness values, because
|
||||
# the defect was invisible to every single-value check that happened to sit
|
||||
# inside one stage.
|
||||
DEV_LO, DEV_HI = -4000.0, 4000.0
|
||||
escapes = [(m, clamp_to_rating(m, 5000.0, DEV_LO, DEV_HI).applied_w)
|
||||
for m in range(-15000, 15001, 61)
|
||||
for a in [clamp_to_rating(m, 5000.0, DEV_LO, DEV_HI).applied_w]
|
||||
if not (DEV_LO <= a <= DEV_HI)]
|
||||
big = clamp_to_rating(9999.0, 5000.0, DEV_LO, DEV_HI)
|
||||
small = clamp_to_rating(4500.0, 5000.0, DEV_LO, DEV_HI)
|
||||
print(f" max_w 5000 vs a device of {DEV_LO:+.0f}..{DEV_HI:+.0f}: "
|
||||
f"+9999 -> {big.applied_w:+.0f} W ({big.bound}), "
|
||||
f"+4500 -> {small.applied_w:+.0f} W ({small.bound})")
|
||||
check(f"BOTH stages always run - {big.requested_w:+.0f} W emits "
|
||||
f"{big.applied_w:+.0f} W, inside the device's {DEV_HI:+.0f} W, and names "
|
||||
f"both bounds ({big.bound!r})",
|
||||
big.applied_w == DEV_HI and big.bound == "max_w+device")
|
||||
check(f"...and it holds over the whole range, so no overshoot escapes the "
|
||||
f"device ({len(escapes)} escapes in {len(range(-15000, 15001, 61))})",
|
||||
not escapes)
|
||||
check("...a big overshoot is not clamped LESS than a small one",
|
||||
abs(big.applied_w) <= abs(small.applied_w) + 0.0)
|
||||
|
||||
print(" non-finite input is loss of input, not an out-of-range value")
|
||||
for bad in (None, float("nan"), float("inf"), float("-inf"), "abc", object()):
|
||||
check(f"is_commandable({bad!r:.30}) is False", is_commandable(bad) is False)
|
||||
for good in (0, -5000.0, 5000, 12.5):
|
||||
check(f"is_commandable({good!r}) is True", is_commandable(good) is True)
|
||||
|
||||
# ⚠️ WHY THAT GUARD EXISTS, AND THE ANSWER IS WORSE THAN "it passes a nan
|
||||
# through". MEASURED HERE, not recalled: every comparison against a nan is
|
||||
# False, so `min(limit, nan)` keeps its FIRST argument and a naive clamp turns a
|
||||
# nan into a command at the FULL RATING - and then reports engaged=True, because
|
||||
# limit != nan, so the winding-loop counter gets a transport bug filed in it.
|
||||
# The number below is computed by the same expression the guard replaces.
|
||||
nan = float("nan")
|
||||
naive = max(-LIVE_MAX_W, min(LIVE_MAX_W, nan))
|
||||
check(f"a naive clamp turns a nan into {naive:+,.0f} W and calls it "
|
||||
f"engaged={naive != nan} - hence the guard",
|
||||
naive == LIVE_MAX_W and (naive != nan) is True)
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("2. the alarm's cadence: every engagement counted, no flood")
|
||||
|
||||
wd = ClampWatchdog()
|
||||
t = T0
|
||||
fired = [wd.note(True, "winding", t + timedelta(seconds=i)) for i in range(10)]
|
||||
check(f"the rising edge fires ({fired[0]})", fired[0] is True)
|
||||
check(f"the next 9 one-second cycles fire {sum(fired[1:])} more times "
|
||||
f"(re-assert is {REASSERT_S:.0f} s)", sum(fired[1:]) == 0)
|
||||
check(f"but every one of them is counted: engagements={wd.engagements}",
|
||||
wd.engagements == 10)
|
||||
check(f"and it is one episode, not ten: episodes={wd.episodes}",
|
||||
wd.episodes == 1)
|
||||
|
||||
# --- THE RE-ASSERT CADENCE, PINNED IN BOTH DIRECTIONS ------------------------
|
||||
# ⚠️ REVIEW-FOUND. This used to read `wd.note(True, ..., T0 + REASSERT_S + 9)`,
|
||||
# which is green for ANY value of the constant - REASSERT_S = 3600 passed, and an
|
||||
# hour of silence is precisely what the module promises not to do. A check whose
|
||||
# stimulus is written in terms of the constant it is grading cannot grade it.
|
||||
#
|
||||
# The requirements are stated in wall-clock seconds and derived from what the
|
||||
# alarm is FOR, so they do not move when the constant does:
|
||||
#
|
||||
# floor - a loop pinned on the rail must speak at least MIN_PER_QUARTER times
|
||||
# inside the 900 s quarter that bills the capacity tariff. That window
|
||||
# is the same one freeze.py and DOCS.md reason about.
|
||||
# ceiling - it must not speak on more than MAX_FRACTION of cycles, or it is
|
||||
# the per-cycle flood the split exists to remove.
|
||||
QUARTER_S = 900.0
|
||||
MIN_PER_QUARTER = 5
|
||||
MAX_FRACTION = 0.20
|
||||
|
||||
pinned = ClampWatchdog()
|
||||
alarms = sum(1 for i in range(int(QUARTER_S))
|
||||
if pinned.note(True, "pinned", T0 + timedelta(seconds=i)))
|
||||
print(f" pinned on the rail for {QUARTER_S:.0f} s at 1 s cycles: "
|
||||
f"{pinned.engagements} engagements, {alarms} alarm(s) "
|
||||
f"({alarms / QUARTER_S:.1%} of cycles)")
|
||||
check(f"a loop pinned for a whole billing quarter speaks at least "
|
||||
f"{MIN_PER_QUARTER} times (it spoke {alarms})",
|
||||
alarms >= MIN_PER_QUARTER)
|
||||
check(f"...and on no more than {MAX_FRACTION:.0%} of cycles (it was "
|
||||
f"{alarms / QUARTER_S:.1%})", alarms <= MAX_FRACTION * QUARTER_S)
|
||||
check("...while every single cycle is still counted",
|
||||
pinned.engagements == int(QUARTER_S))
|
||||
|
||||
# --- THE HYSTERESIS, PINNED AGAINST THE CHATTER DIRECTION --------------------
|
||||
# ⚠️ REVIEW-FOUND. This used to issue `range(CLEAR_CYCLES - 1)` clean cycles,
|
||||
# which at CLEAR_CYCLES = 1 issues ZERO of them and passes while printing
|
||||
# "0 clean cycles do NOT clear it". Green for every value >= 1 - including 1,
|
||||
# which IS the chatter the constant exists to prevent. The stimulus is a literal
|
||||
# now: ONE clean cycle must not clear the alarm, whatever the constant says.
|
||||
wd2 = ClampWatchdog()
|
||||
wd2.note(True, "winding", T0)
|
||||
wd2.note(False, "", T0 + timedelta(seconds=1))
|
||||
check(f"ONE clean cycle does NOT clear the alarm (active={wd2.active}) - "
|
||||
f"a command dithering across the rail must not chatter",
|
||||
wd2.active is True)
|
||||
survived = 1
|
||||
while wd2.active and survived < 50:
|
||||
wd2.note(False, "", T0 + timedelta(seconds=1 + survived))
|
||||
survived += 1
|
||||
print(f" it took {survived} consecutive clean cycles to de-assert "
|
||||
f"(CLEAR_CYCLES = {CLEAR_CYCLES})")
|
||||
check(f"...and it does de-assert, after {survived} of them, rather than "
|
||||
f"latching", wd2.active is False and survived == CLEAR_CYCLES)
|
||||
check("...and the engagement count survives the clear, so the evidence does",
|
||||
wd2.engagements == 1)
|
||||
check("a clean cycle on an idle watchdog says nothing",
|
||||
wd2.note(False, "", T0 + timedelta(seconds=300)) is False)
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("3. AC 1 + AC 3, wired: over the rating both clamps AND alarms")
|
||||
|
||||
|
||||
class _Store:
|
||||
data = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
class _Hass:
|
||||
"""Stub HA. `track` False models an inverter that is switched off entirely,
|
||||
which is the 10.3 runaway's own setup."""
|
||||
|
||||
def __init__(self, grid, batt=0.0, track=True):
|
||||
self.grid = grid
|
||||
self.batt = batt
|
||||
self.track = track
|
||||
self.calls = []
|
||||
self.writes = []
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-LIVE_MAX_W, LIVE_MAX_W, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
return {"sensor.grid": self.grid, "sensor.soc": 50.0,
|
||||
"sensor.batt": self.batt}.get(entity)
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
if self.track:
|
||||
self.batt = float(value)
|
||||
return True
|
||||
|
||||
async def call(self, domain, service, data):
|
||||
self.calls.append((domain, service, data))
|
||||
return True
|
||||
|
||||
|
||||
def wired(grid, cycles=40, batt=0.0, track=True, **over):
|
||||
async def go():
|
||||
hass = _Hass(grid, batt=batt, track=track)
|
||||
c = Controller(dict(
|
||||
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": LIVE_MAX_W, "gain": 0.6,
|
||||
"slew_w": 1000, "deadband_w": 15, "target_grid_w": 0,
|
||||
"step_w": 10, "heartbeat_s": 10, "stale_input_s": 15},
|
||||
**over), hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
# The red status row exists only WHILE the clamp is engaged, and the
|
||||
# hysteresis clears it a few cycles later - so it is captured live
|
||||
# rather than looked for after the run, when it is correctly gone.
|
||||
c.red_snapshot = []
|
||||
for _ in range(cycles):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
if c.clamp_wd.active and not c.red_snapshot:
|
||||
c.red_snapshot = c.checks()
|
||||
return hass, c
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
def clamp_notes(hass):
|
||||
return [d for dom, svc, d in hass.calls
|
||||
if (dom, svc) == ("persistent_notification", "create")
|
||||
and d.get("notification_id") == CLAMP_ID]
|
||||
|
||||
|
||||
# THE 10.3 RUNAWAY, replayed. "With the inverter switched off entirely, an
|
||||
# unclamped integrator climbed ~130 W per 4 s to over 10 kW and, pinned at the
|
||||
# 5 kW rail, reported 14 768 W." `track=False` is the inverter switched off: it
|
||||
# reports 0 W however hard it is commanded, so the error never closes.
|
||||
hass_r, ctl_r = wired(6000.0, cycles=60, track=False)
|
||||
emitted = [abs(w) for w in hass_r.writes]
|
||||
|
||||
# What the SAME error would have done to an accumulator with no bound - the
|
||||
# transcription is deliberately the unclamped velocity form 10.3 describes, so
|
||||
# the figure below is computed here and not quoted from the spec.
|
||||
runaway, err = 0.0, 6000.0
|
||||
for _ in range(60):
|
||||
runaway += 0.6 * err
|
||||
print(f" unclamped, the same 60 cycles reach {runaway:,.0f} W; "
|
||||
f"the largest value that reached the device is {max(emitted):,.0f} W")
|
||||
check(f"an unbounded accumulator really does run away here "
|
||||
f"({runaway:,.0f} W >> {LIVE_MAX_W:.0f} W)", runaway > 3 * LIVE_MAX_W)
|
||||
check(f"AC 1: NOT ONE of the {len(emitted)} values that reached the device "
|
||||
f"exceeds the {LIVE_MAX_W:.0f} W rating",
|
||||
emitted and max(emitted) <= LIVE_MAX_W)
|
||||
# ⚠️ AND THE CLAMP IS NOT THE ONLY THING HOLDING THAT LINE HERE, which is worth
|
||||
# saying out loud rather than letting the number above imply otherwise. Against
|
||||
# an inverter reporting 0 W the saturation freeze engages after
|
||||
# `saturation_cycles` and pins the command well BELOW the rail - that is why the
|
||||
# largest emitted value is what it is and not 5000 W. The clamp is what makes it
|
||||
# bounded; the freeze is what makes it small. A check that read
|
||||
# `max(emitted) == max_w` would have been asserting the freeze, not the clamp.
|
||||
check(f"...and the saturation freeze is what pins it at {max(emitted):,.0f} W "
|
||||
f"rather than the rail", ctl_r.sat_count >= ctl_r.tuning.saturation_cycles)
|
||||
|
||||
notes_r = clamp_notes(hass_r)
|
||||
print(f" the loop clamped on {ctl_r.clamp_wd.engagements} of {60} cycles, "
|
||||
f"in {ctl_r.clamp_wd.episodes} episode(s), raising {len(notes_r)} "
|
||||
f"notification(s)")
|
||||
check("AC 3: and it ALARMED - silently clipping this is the defect",
|
||||
ctl_r.clamp_wd.engagements > 0 and len(notes_r) >= 1)
|
||||
check("...with its own notification_id, not shared with any other guard",
|
||||
all(d["notification_id"] == CLAMP_ID for d in notes_r))
|
||||
check("...one episode, re-asserted rather than one per cycle",
|
||||
ctl_r.clamp_wd.episodes == 1 and len(notes_r) < ctl_r.clamp_wd.engagements)
|
||||
check("...and it names itself a bug signal, not a limit in use",
|
||||
bool(notes_r) and "out of range" in notes_r[0]["message"])
|
||||
rows_r = [e for e in ctl_r.events if REASON_CODE in e]
|
||||
check(f"the action log records every engagement, coalesced into one row per "
|
||||
f"episode ({len(rows_r)} row(s), {ctl_r.clamp_wd.engagements} "
|
||||
f"engagement(s))",
|
||||
len(rows_r) == ctl_r.clamp_wd.episodes
|
||||
and f"{ctl_r.clamp_wd.engagements} engagement(s)" in rows_r[0])
|
||||
|
||||
# ⚠️ REGRESSION, AND IT WAS A REAL BUG BEFORE IT WAS A CHECK. `log_event()` keeps
|
||||
# 40 rows. A row per engagement flushes that ring inside 40 cycles of a winding
|
||||
# loop, and the first thing it evicted was SAFETY-18's own "METER FROZEN?" row -
|
||||
# i.e. this guard silencing another guard's log. Driven here with a plant that
|
||||
# TRACKS the command, so the saturation freeze never engages and the integrator
|
||||
# clamps on essentially every cycle.
|
||||
hass_l, ctl_l = wired(9000.0, cycles=80, track=True)
|
||||
rows_l = [e for e in ctl_l.events if REASON_CODE in e]
|
||||
other_l = [e for e in ctl_l.events if REASON_CODE not in e]
|
||||
print(f" 80 winding cycles: {ctl_l.clamp_wd.engagements} engagement(s) -> "
|
||||
f"{len(rows_l)} log row(s), leaving room for {len(other_l)} other event(s)")
|
||||
check(f"a long winding episode does NOT flood the 40-row event log "
|
||||
f"({len(rows_l)} rows for {ctl_l.clamp_wd.engagements} engagements)",
|
||||
ctl_l.clamp_wd.engagements > 40 and len(rows_l) <= ctl_l.clamp_wd.episodes)
|
||||
check("...and the count in the row is the counter's, so nothing is lost",
|
||||
f"{ctl_l.clamp_wd.engagements} engagement(s)" in rows_l[-1])
|
||||
# The RED row exists only while engaged, and the episode above is short, so it
|
||||
# is captured mid-run rather than asserted after the hysteresis has cleared it.
|
||||
check("the status page goes red WHILE it is engaged",
|
||||
any(not c["ok"] and not c["warn"] and "OUTPUT CLAMP ENGAGED" in c["text"]
|
||||
for c in ctl_r.red_snapshot))
|
||||
check("...and once clear, a warn row still says how many times it engaged",
|
||||
any(c["warn"] and f"{ctl_r.clamp_wd.engagements} time(s)" in c["text"]
|
||||
for c in ctl_r.checks()))
|
||||
|
||||
# ⚠️ NOT A TRIP. 11.2's action is "clamp and alarm"; the loop keeps running and
|
||||
# keeps writing the clamped value. If a later cut changes that it must come here.
|
||||
check(f"it is NOT a trip - the command stands at {ctl_r.target:+.0f} W, not 0 W",
|
||||
ctl_r.target != 0.0 and ctl_r.target == hass_r.writes[-1])
|
||||
check("...and the controller still reports itself running, not failsafe",
|
||||
ctl_r.auto and not ctl_r.sign_wd.tripped)
|
||||
|
||||
# The export side, because the clamp is a magnitude clamp and a sign bug in it
|
||||
# would be invisible on the import case alone.
|
||||
hass_x, ctl_x = wired(-6000.0, cycles=60, track=False)
|
||||
check(f"the export side clamps and alarms too "
|
||||
f"({min(hass_x.writes):+,.0f} W, {len(clamp_notes(hass_x))} note(s), "
|
||||
f"{ctl_x.clamp_wd.engagements} engagement(s))",
|
||||
min(hass_x.writes) < 0 and abs(min(hass_x.writes)) <= LIVE_MAX_W
|
||||
and clamp_notes(hass_x) and ctl_x.clamp_wd.engagements > 0)
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("4. AC 2: saturation WITHOUT clamping must NOT raise a clamp alarm")
|
||||
|
||||
# A legal command the inverter will not follow. The meter sits just outside the
|
||||
# deadband so the loop moves a little and then rests; `batt` is pinned far from
|
||||
# whatever is commanded, which is the saturation condition (|cmd - actual| >
|
||||
# saturation_w) and nothing else. The integrator never approaches the rating.
|
||||
hass_s, ctl_s = wired(60.0, cycles=40, batt=2500.0, track=False)
|
||||
peak = max(abs(w) for w in hass_s.writes)
|
||||
print(f" saturated for {ctl_s.sat_count} consecutive cycles; the command "
|
||||
f"peaked at {peak:.0f} W, {peak / LIVE_MAX_W:.1%} of the rating")
|
||||
# ⚠️ THE POSITIVE HALF FIRST. A negative check that saw nothing happen is not an
|
||||
# observation - if the saturation freeze never engaged, "no clamp alarm" is
|
||||
# vacuous and this check is worthless.
|
||||
check(f"the saturation freeze REALLY DID engage (sat_count="
|
||||
f"{ctl_s.sat_count} >= {ctl_s.tuning.saturation_cycles})",
|
||||
ctl_s.sat_count >= ctl_s.tuning.saturation_cycles)
|
||||
check("...and the event log says so, in the saturation's own words",
|
||||
any("saturation freeze" in e for e in ctl_s.events))
|
||||
check(f"...while the command stayed well inside the rating "
|
||||
f"({peak:.0f} W < {LIVE_MAX_W:.0f} W)", peak < LIVE_MAX_W)
|
||||
# Now the negative, which is only worth anything because of the three above.
|
||||
check("AC 2: NO clamp notification was raised", not clamp_notes(hass_s))
|
||||
check("AC 2: the clamp counted ZERO engagements", ctl_s.clamp_wd.engagements == 0)
|
||||
check("AC 2: no OUTPUT_CLAMP row in the action log",
|
||||
not [e for e in ctl_s.events if REASON_CODE in e])
|
||||
check("AC 2: and no clamp row on the status page",
|
||||
not [c for c in ctl_s.checks() if "output clamp" in c["text"].lower()])
|
||||
|
||||
print(" ...and the two alarms do not share a notification_id")
|
||||
ids_clamp = {d["notification_id"] for d in clamp_notes(hass_r)}
|
||||
ids_other = {d.get("notification_id") for dom, svc, d in hass_r.calls
|
||||
if svc == "create"} - ids_clamp
|
||||
check(f"clamp ids {sorted(ids_clamp)} are disjoint from every other alarm's "
|
||||
f"{sorted(x for x in ids_other if x)}", not (ids_clamp & ids_other))
|
||||
|
||||
print(" ...and the alarm cannot be keyed on Decision.reason")
|
||||
# A cycle that clamps the integrator AND is then slew limited. `reason` reports
|
||||
# the LAST stage, so a string-keyed alarm is silent on it; the boolean is not.
|
||||
t = Tuning(max_w=2000.0, slew_w=100.0, gain=0.6)
|
||||
d = compute(prev_w=1000.0, grid_w=6000.0, actual_w=1000.0, tuning=t, i_w=1900.0)
|
||||
print(f" reason={d.reason!r} i_clamped={d.i_clamped} clamped={d.clamped}")
|
||||
check("the integrator DID clamp on that cycle", d.i_clamped is True)
|
||||
check("...but `reason` says 'slew-limited' - the clamp was overwritten "
|
||||
"downstream, so a string-keyed alarm is SILENT here",
|
||||
d.reason == "slew-limited" and "clamp" not in d.reason)
|
||||
# And the same for the OUTPUT clamp, on a config that lets the integrator run
|
||||
# above the rail - then both flags fire and `reason` still reports neither.
|
||||
t2 = Tuning(max_w=2000.0, integrator_max_w=3000.0, slew_w=100.0, gain=0.6)
|
||||
d2 = compute(prev_w=1000.0, grid_w=6000.0, actual_w=1000.0, tuning=t2, i_w=2900.0)
|
||||
print(f" reason={d2.reason!r} i_clamped={d2.i_clamped} clamped={d2.clamped}")
|
||||
check("both clamps engaged, and `reason` reports neither",
|
||||
d2.i_clamped and d2.clamped and "clamp" not in d2.reason)
|
||||
# ⚠️ HOW THE FREEZE AND THE CLAMP INTERACT, MEASURED RATHER THAN ASSUMED, AND
|
||||
# THE MEASUREMENT REFUSED TWO GUESSES BEFORE THIS ONE. Written first as "a
|
||||
# frozen cycle never clamps" (false), then as "only the i_w == 0 reseed
|
||||
# exception clamps" (also false - at i_w == 0 with a matching actual the cycle
|
||||
# is not saturated at all, so it is never frozen). What the sweep actually
|
||||
# shows: a frozen cycle clamps exactly when the integrator REVERSES. control.py
|
||||
# permits that on purpose - "it may fall, cross zero, or reverse outright" -
|
||||
# because the alternative deadlocks the loop, and a reversal is a full swing
|
||||
# that can clear the bound on the far side in one step.
|
||||
#
|
||||
# That matters for this ticket rather than being trivia: it is the one shape
|
||||
# where the saturation freeze and a clamp engagement coincide, so it is exactly
|
||||
# where an alarm that shared a channel with saturation would lose the clamp.
|
||||
grid_sweep = (-9000.0, -3000.0, 3000.0, 9000.0)
|
||||
grid = [(pp, g) for pp in (-1900.0, -500.0, 0.0, 500.0, 1900.0)
|
||||
for g in grid_sweep]
|
||||
runs = {(pp, g): compute(pp, g, 0.0, t, sat_count=5, i_w=pp) for pp, g in grid}
|
||||
frozen = [k for k, d in runs.items() if d.frozen]
|
||||
frozen_clamps = [k for k in frozen if runs[k].i_clamped]
|
||||
# The property, stated independently of the control law's own branches: the
|
||||
# correction pushes AGAINST the standing integrator, and the resulting swing
|
||||
# clears the bound.
|
||||
reversals = [(pp, g) for pp, g in frozen
|
||||
if pp * g < 0 and abs(pp + t.gain * g) > t.max_w]
|
||||
print(f" {len(frozen)} of {len(grid)} sweep cells are frozen; "
|
||||
f"those that also clamp: {frozen_clamps}")
|
||||
check(f"a frozen cycle CAN clamp, and only by reversing "
|
||||
f"({len(frozen_clamps)} of {len(frozen)} frozen cells)",
|
||||
frozen_clamps and frozen_clamps == reversals)
|
||||
check("...and a frozen cycle pushing the way it already leans never clamps - "
|
||||
"that is the freeze doing its job",
|
||||
not [k for k in frozen if runs[k].i_clamped and k[0] * k[1] > 0])
|
||||
check("a healthy cycle sets neither flag",
|
||||
not any([compute(0.0, 100.0, 0.0, t).i_clamped,
|
||||
compute(0.0, 100.0, 0.0, t).clamped]))
|
||||
|
||||
|
||||
# ==============================================================================
|
||||
print()
|
||||
print("5. no path reaches the wire around the clamp")
|
||||
|
||||
|
||||
async def _direct():
|
||||
hass = _Hass(0.0)
|
||||
c = Controller({"setpoint_entity": "number.sp", "max_w": 2000,
|
||||
"meter_source": "off"},
|
||||
hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.dev_min, c.dev_max = -LIVE_MAX_W, LIVE_MAX_W
|
||||
# The shape the heartbeat, shutdown() and handle_action() all use.
|
||||
await c.write_setpoint(9999.0, force=True)
|
||||
await c.write_setpoint(-9999.0, force=True)
|
||||
await c.write_setpoint(float("nan"), force=True)
|
||||
await c.write_setpoint(1500.0, force=True)
|
||||
return hass, c
|
||||
|
||||
|
||||
hass_d, ctl_d = asyncio.run(_direct())
|
||||
print(f" asked for 9999 / -9999 / nan / 1500 W; the device saw "
|
||||
f"{hass_d.writes}")
|
||||
check("a direct out-of-range write is clamped, not passed through",
|
||||
hass_d.writes[:2] == [2000.0, -2000.0])
|
||||
check("a nan is refused and becomes 0 W, per 11.1 rule 1",
|
||||
hass_d.writes[2] == 0.0)
|
||||
check("...and is NOT counted as a clamp engagement - it is a transport bug",
|
||||
sum(1 for e in ctl_d.events if REASON_CODE in e) == 2)
|
||||
check("an in-range value is untouched", hass_d.writes[3] == 1500.0)
|
||||
check("every emitted frame satisfies |emitted| <= the rating",
|
||||
all(abs(w) <= 2000.0 for w in hass_d.writes))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -0,0 +1,554 @@
|
||||
"""Runnable check for SAFETY-18, the frozen-but-fresh meter detector.
|
||||
|
||||
python3 test_freeze.py
|
||||
|
||||
Three parts, and the last two are the ones that matter:
|
||||
|
||||
1. the predicate's boundaries and the edge-trigger, table-driven;
|
||||
2. SILENT ON REAL CONVERGED DATA. `scenarios/p1-age-2026-08-26.jsonl.gz` is
|
||||
40 minutes of this house's live meter at the operating point, committed
|
||||
here from the infra repo's `sim/scenarios/`. It is replayed through the
|
||||
REAL `control.compute()` at the real cycle rule, and the detector must not
|
||||
make a sound. This is the acceptance criterion TEL-05's objection is
|
||||
about, and it is verified rather than argued;
|
||||
3. FIRES ON A GENUINELY FROZEN METER, over real HTTP, through the REAL
|
||||
`HomeWizardLocalSource` - the transport is what computes `unchanged_s`, so
|
||||
a check that calls the predicate directly would not be testing the thing
|
||||
that ships. Uses the rig's own `sim/hwsim.py --fault freeze` when the infra
|
||||
repo is next to this one (or `$GOODWE_SIM`), and an equivalent local stub
|
||||
otherwise. Both are exercised; the run says which one it used.
|
||||
|
||||
⚠️ Part 3 runs in WALL CLOCK - `unchanged_s` is `time.monotonic()` and the
|
||||
transport really polls - so it drives the detector at `hold_s=10`, not the
|
||||
shipped 300. The THRESHOLD is config; the MECHANISM is what is under test, and
|
||||
the mechanism cannot be hurried. Part 2 uses the shipped 300 because that data
|
||||
is replayed rather than lived.
|
||||
|
||||
⚠️ Part 3 also runs its NEGATIVE twin, and that is the load-bearing half: the
|
||||
same railed command against a meter that is still MOVING, at the same 10 s
|
||||
threshold. If that one alarms, the detector is a `unchanged_s` threshold with
|
||||
extra steps and the whole reason for the conjunction is gone.
|
||||
|
||||
------------------------------------------------------------------------------
|
||||
THE RIG RUN THIS STANDS IN FOR
|
||||
|
||||
Part 3 is the portable version of a run done on the real rig - the `goodwe-sim`
|
||||
compose project on 192.168.2.147, under `sim/riglock.py`, with the driver staged
|
||||
into `goodwe-sim-plant` so it polls that container's own hwsim while plantsim
|
||||
drives it. Both phases passed there. To repeat it:
|
||||
|
||||
DOCKER_HOST=ssh://homelab@192.168.2.147 python sim/riglock.py status
|
||||
|
||||
⚠️ WITHOUT `DOCKER_HOST` SET, ON A WINDOWS HOST, `riglock status` REPORTS
|
||||
`rig: UNKNOWN` - it shells out to the local `docker` CLI, which resolves to a
|
||||
Docker Desktop npipe that is not running. That is INDISTINGUISHABLE from a
|
||||
genuinely absent rig, and it is not one: the rig lives on the homelab box and was
|
||||
up the whole time. `UNKNOWN` is the tool declining to observe, not an
|
||||
observation. Do not read it as "no rig" (this cost this ticket a wrong caveat).
|
||||
|
||||
The rig run also produced a result part 3's stub cannot: under +8000 W of house
|
||||
load the meter's POWER FIGURE never moved - 10130.0 W for 26 consecutive polls -
|
||||
and only the kWh registers kept `unchanged_s` at zero. See the note in
|
||||
freeze.py; it is why the fingerprint's register terms are the negative case
|
||||
rather than a nicety.
|
||||
"""
|
||||
|
||||
import asyncio
|
||||
import gzip
|
||||
import json
|
||||
import os
|
||||
import subprocess
|
||||
import sys
|
||||
import time
|
||||
from datetime import datetime, timedelta, timezone
|
||||
from pathlib import Path
|
||||
|
||||
import aiohttp
|
||||
|
||||
from app.control import Tuning, compute
|
||||
from app.freeze import (
|
||||
RAIL_FRAC, FreezeWatchdog, FreezeWatchdogConfig, looks_frozen, rail_w,
|
||||
)
|
||||
from app.main import Controller
|
||||
from app.p1 import HomeWizardLocalSource, P1Ingest
|
||||
|
||||
fails = []
|
||||
T0 = datetime(2026, 8, 26, 7, 0, 0, tzinfo=timezone.utc)
|
||||
HERE = Path(__file__).resolve().parent
|
||||
|
||||
# The live install's numbers, which are the ones the exposure is written at.
|
||||
LIVE_MAX_W = 5000.0
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
def tuning(max_w=LIVE_MAX_W):
|
||||
"""The shipped defaults from config.yaml, at the live install's max_w."""
|
||||
return Tuning(gain=0.6, max_w=max_w, slew_w=1000, deadband_w=15,
|
||||
target_grid_w=-10, step_w=10, saturation_w=500,
|
||||
saturation_cycles=3)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 1. the predicate and the edge
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("predicate")
|
||||
cfg = FreezeWatchdogConfig(hold_s=300)
|
||||
|
||||
check("both terms true -> frozen", looks_frozen(300, 5000, 5000, cfg))
|
||||
check("unchanged long, command NOT railed -> silent (TEL-05's case)",
|
||||
not looks_frozen(3600, -40, 5000, cfg))
|
||||
check("command railed, meter still moving -> silent (a real 8 kW load)",
|
||||
not looks_frozen(4, -5000, 5000, cfg))
|
||||
check("neither -> silent", not looks_frozen(4, -40, 5000, cfg))
|
||||
check("one second under the hold is still silent",
|
||||
not looks_frozen(299.9, 5000, 5000, cfg))
|
||||
check("just under the rail fraction is still silent",
|
||||
not looks_frozen(3600, 5000 * RAIL_FRAC - 1, 5000, cfg))
|
||||
check("at the rail fraction exactly, it fires",
|
||||
looks_frozen(3600, 5000 * RAIL_FRAC, 5000, cfg))
|
||||
check("the rail scales with max_w, not with a fixed watt figure",
|
||||
looks_frozen(3600, 2000, 2000, cfg) and not looks_frozen(3600, 2000, 5000, cfg))
|
||||
check("a charge rail counts too - the runaway can be either sign",
|
||||
looks_frozen(3600, -5000, 5000, cfg))
|
||||
check("no transport signal (unchanged_s None) -> silent, never assumed frozen",
|
||||
not looks_frozen(None, 5000, 5000, cfg))
|
||||
check("no command yet -> silent", not looks_frozen(3600, None, 5000, cfg))
|
||||
check("rail_w tracks RAIL_FRAC", rail_w(5000) == 5000 * RAIL_FRAC)
|
||||
|
||||
print("the edge")
|
||||
wd = FreezeWatchdog(cfg)
|
||||
edges = [wd.evaluate(u, c, 5000, T0 + timedelta(seconds=i))
|
||||
for i, (u, c) in enumerate(
|
||||
[(10, 5000), (300, 5000), (305, 5000), (310, 5000),
|
||||
(2, 5000), (300, 5000)])]
|
||||
check("rises exactly once per episode", edges == [False, True, False, False,
|
||||
False, True])
|
||||
check("two episodes counted", wd.episodes == 2)
|
||||
check("clearing the condition clears the alarm state",
|
||||
not FreezeWatchdog(cfg).evaluate(2, 5000, 5000, T0))
|
||||
check("the reason names both terms",
|
||||
"unchanged over 300" in wd.reason and "command over 4750" in wd.reason)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 2. silent on 40 minutes of real converged behaviour
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("converged replay - scenarios/p1-age-2026-08-26.jsonl.gz")
|
||||
rows = [json.loads(line) for line in
|
||||
gzip.open(HERE / "scenarios" / "p1-age-2026-08-26.jsonl.gz", "rt")]
|
||||
check("the capture loaded", len(rows) > 1000)
|
||||
|
||||
# ⚠️ The capture records the POWER figure only. The shipped fingerprint also
|
||||
# covers both kWh registers, so a real `unchanged_s` on this data can only be
|
||||
# SHORTER than what is reconstructed here - this replay is the pessimistic
|
||||
# version of the converged case, not a flattering one.
|
||||
def replay(hold_s, max_w, cycle_floor_s=15.0):
|
||||
"""Drive the real control law and the real detector over the capture."""
|
||||
wd = FreezeWatchdog(FreezeWatchdogConfig(hold_s=hold_s))
|
||||
t = tuning(max_w)
|
||||
target, i_w, sat = 0.0, 0.0, 0
|
||||
prev_pwr, changed_at = None, rows[0]["t"]
|
||||
last_cycle = None
|
||||
peak_cmd, peak_unchanged, fired_at = 0.0, 0.0, None
|
||||
for r in rows:
|
||||
now, pwr = r["t"], float(r["pwr"])
|
||||
if prev_pwr is None or pwr != prev_pwr:
|
||||
changed_at = now
|
||||
arrival = (prev_pwr is None or pwr != prev_pwr)
|
||||
prev_pwr = pwr
|
||||
# main.run_control()'s rule: a cycle per changed reading, or the floor.
|
||||
if arrival or last_cycle is None or now - last_cycle >= cycle_floor_s:
|
||||
last_cycle = now
|
||||
d = compute(prev_w=target, grid_w=pwr, actual_w=target, tuning=t,
|
||||
sat_count=sat, i_w=i_w)
|
||||
target, i_w, sat = d.target_w, d.i_w, d.sat_count
|
||||
# ⚠️ The detector is evaluated on EVERY poll, not only on cycles, and
|
||||
# that is deliberately harsher than the shipped wiring (which evaluates
|
||||
# it inside cycle()). On an arrival-triggered cycle `unchanged_s` is 0
|
||||
# by construction, so grading only there would be grading the detector
|
||||
# on the one sample it cannot possibly fire on.
|
||||
unchanged = now - changed_at
|
||||
peak_cmd = max(peak_cmd, abs(target))
|
||||
peak_unchanged = max(peak_unchanged, unchanged)
|
||||
if wd.evaluate(unchanged, target, max_w,
|
||||
T0 + timedelta(seconds=now - rows[0]["t"])) \
|
||||
and fired_at is None:
|
||||
fired_at = now - rows[0]["t"]
|
||||
return wd, peak_cmd, peak_unchanged, fired_at
|
||||
|
||||
|
||||
for mw in (2000.0, LIVE_MAX_W):
|
||||
wd_r, peak_cmd, peak_unchanged, fired = replay(300.0, mw)
|
||||
print(f" max_w {mw:.0f}: worst |command| {peak_cmd:.0f} W (rail "
|
||||
f"{rail_w(mw):.0f} W), worst unchanged {peak_unchanged:.1f} s "
|
||||
f"(hold 300 s), episodes {wd_r.episodes}")
|
||||
check(f"max_w {mw:.0f}: never alarms on the converged capture", fired is None)
|
||||
check(f"max_w {mw:.0f}: and the rail term had margin to spare",
|
||||
peak_cmd < rail_w(mw))
|
||||
|
||||
# The margin on the OTHER term, as numbers rather than as trust. Both figures
|
||||
# are quoted in config.yaml and freeze.py, so they are re-measured every run and
|
||||
# a capture swapped underneath them cannot leave the prose saying the old thing.
|
||||
_, _, worst_unchanged, _ = replay(300.0, LIVE_MAX_W)
|
||||
gaps, last, prev = [], rows[0]["t"], None
|
||||
for r in rows:
|
||||
if prev is None or r["pwr"] != prev:
|
||||
gaps.append(r["t"] - last)
|
||||
last = r["t"]
|
||||
prev = r["pwr"]
|
||||
print(f" longest unchanged_s any sample would observe: {worst_unchanged:.1f} s")
|
||||
print(f" longest interval serving no distinct reading: {max(gaps):.1f} s "
|
||||
f"(spans an 11.4 s hole in the capture's own polling)")
|
||||
check("worst observed unchanged_s is the 8 s the docs quote",
|
||||
7.5 < worst_unchanged < 8.5)
|
||||
check("longest distinct-reading interval is the 15.4 s the docs quote",
|
||||
15.0 < max(gaps) < 16.0)
|
||||
check("300 s is at least 15x the worst of the two", 300.0 >= 15 * max(gaps))
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 2b. TEL-05's case, reconstructed, because the capture cannot contain it
|
||||
# --------------------------------------------------------------------------- #
|
||||
# ⚠️ BE HONEST ABOUT WHAT THE CAPTURE ABOVE PROVES AND WHAT IT DOES NOT. On this
|
||||
# house's meter the power figure jitters at 1 W, so the worst `unchanged_s` any
|
||||
# sample sees is 8 s - which means the capture alone does NOT refute a bare
|
||||
# `unchanged_s > 300` threshold, and reporting it as though it did would be the
|
||||
# confident explanation nobody checked. The case that refutes the bare threshold
|
||||
# is the one p1.py describes and no capture of THIS meter contains: a converged
|
||||
# meter whose power figure simply repeats, where the 1 Wh export register needs
|
||||
# 360 s to advance at -10 W and the fingerprint therefore stands still.
|
||||
#
|
||||
# So it is constructed, from the operating point the capture measures (mean grid
|
||||
# -14.2 W) rather than invented: one hour of a perfectly healthy converged meter
|
||||
# that happens not to move.
|
||||
print("TEL-05's low-power case - a converged meter that legitimately repeats")
|
||||
tel05 = FreezeWatchdog(FreezeWatchdogConfig(hold_s=300))
|
||||
t5 = tuning(LIVE_MAX_W)
|
||||
tgt, iw, sc = 0.0, 0.0, 0
|
||||
bare_would_fire = False
|
||||
tel05_cmd = 0.0
|
||||
for k in range(3600):
|
||||
if k % 15 == 0: # cycle_floor_s, the only trigger left
|
||||
d = compute(prev_w=tgt, grid_w=-14.2, actual_w=tgt, tuning=t5,
|
||||
sat_count=sc, i_w=iw)
|
||||
tgt, iw, sc = d.target_w, d.i_w, d.sat_count
|
||||
tel05_cmd = max(tel05_cmd, abs(tgt))
|
||||
# The REJECTED design, written out so the case can be shown to be real.
|
||||
bare_would_fire = bare_would_fire or float(k) >= 300
|
||||
tel05.evaluate(float(k), tgt, LIVE_MAX_W, T0 + timedelta(seconds=k))
|
||||
print(f" an hour at -14.2 W: worst |command| {tel05_cmd:.0f} W, "
|
||||
f"unchanged_s reaches 3599 s, episodes {tel05.episodes}")
|
||||
check("the bare unchanged_s threshold TEL-05 rejected WOULD fire here",
|
||||
bare_would_fire)
|
||||
check("the conjunction does not - this is what the rail term buys",
|
||||
tel05.episodes == 0)
|
||||
check("...and the command stayed nowhere near the rail",
|
||||
tel05_cmd < rail_w(LIVE_MAX_W))
|
||||
|
||||
# The structural version of the same point, re-derived rather than asserted in
|
||||
# prose: the slowest register a HEALTHY meter can have while still being seen as
|
||||
# unchanged for hold_s is 3600/hold_s watts, and at the shipped defaults that
|
||||
# figure is inside the deadband, so the command there is parked at 0 W. If
|
||||
# someone lowers meter_freeze_s or narrows the deadband, this is the check that
|
||||
# should stop them.
|
||||
DEADBAND_W = 15.0
|
||||
slowest_healthy_w = 3600.0 / 300.0
|
||||
check("a healthy meter slow enough to look unchanged is inside the deadband",
|
||||
slowest_healthy_w < DEADBAND_W)
|
||||
_park = compute(prev_w=0.0, grid_w=-slowest_healthy_w, actual_w=0.0,
|
||||
tuning=tuning(LIVE_MAX_W), sat_count=0, i_w=0.0)
|
||||
check("...and the shipped law really does park the command there",
|
||||
_park.target_w == 0.0)
|
||||
|
||||
# ⚠️ THE PROOF THAT THE REPLAY IS CAPABLE OF FIRING AT ALL. Without this, "the
|
||||
# converged capture is silent" is satisfied by a detector that is wired to
|
||||
# nothing. Drop the hold to 1 s and the rail to nothing, and the SAME replay
|
||||
# must alarm - so the silence above is the data's doing, not the harness's.
|
||||
wd_hot, _, _, fired_hot = replay(1.0, 20.0)
|
||||
check("...and the same replay DOES alarm once both terms are made reachable",
|
||||
fired_hot is not None and wd_hot.episodes > 0)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 3. a genuinely frozen meter, over real HTTP, through the real transport
|
||||
# --------------------------------------------------------------------------- #
|
||||
def find_hwsim():
|
||||
"""The rig's own fake meter, if the infra repo is reachable."""
|
||||
cands = []
|
||||
if os.environ.get("GOODWE_SIM"):
|
||||
cands.append(Path(os.environ["GOODWE_SIM"]) / "hwsim.py")
|
||||
cands.append(HERE.parents[1] / "goodwe" / "sim" / "hwsim.py")
|
||||
for c in cands:
|
||||
if c.exists():
|
||||
return c
|
||||
return None
|
||||
|
||||
|
||||
STUB = r'''
|
||||
import http.server, json, sys, threading, time
|
||||
FROZEN = {"active_power_w": 700.0, "active_power_l1_w": 700.0,
|
||||
"total_power_import_kwh": 1234.567, "total_power_export_kwh": 890.123}
|
||||
moving = len(sys.argv) > 2 and sys.argv[2] == "moving"
|
||||
t0 = time.monotonic()
|
||||
class H(http.server.BaseHTTPRequestHandler):
|
||||
def do_GET(self):
|
||||
d = dict(FROZEN)
|
||||
if moving:
|
||||
# A REAL railed condition: a big steady import, so the power figure
|
||||
# jitters and the 1 Wh registers advance the way physics makes them.
|
||||
el = time.monotonic() - t0
|
||||
d["active_power_w"] = 7000.0 + (int(el * 10) % 7)
|
||||
d["active_power_l1_w"] = d["active_power_w"]
|
||||
d["total_power_import_kwh"] = round(1234.567 + 7000 * el / 3.6e6, 3)
|
||||
raw = json.dumps(d).encode()
|
||||
self.send_response(200)
|
||||
self.send_header("Content-Type", "application/json")
|
||||
self.send_header("Content-Length", str(len(raw)))
|
||||
self.end_headers()
|
||||
self.wfile.write(raw)
|
||||
def log_message(self, *a): pass
|
||||
http.server.ThreadingHTTPServer(("127.0.0.1", int(sys.argv[1])), H).serve_forever()
|
||||
'''
|
||||
|
||||
HWSIM_DRIVER = r'''
|
||||
import sys, threading, time
|
||||
sys.path.insert(0, sys.argv[3])
|
||||
import hwsim
|
||||
hwsim.serve(int(sys.argv[1]))
|
||||
mode = sys.argv[2]
|
||||
hwsim.set_grid(7000.0)
|
||||
if mode == "freeze":
|
||||
hwsim.fault = "freeze" # exactly `hwsim.py --fault freeze`
|
||||
while True:
|
||||
# The plant keeps moving underneath either way. Under `freeze` hwsim's own
|
||||
# set_grid() returns early, which is the whole point of that fault.
|
||||
hwsim.set_grid(7000.0 + (int(time.monotonic() * 10) % 7))
|
||||
time.sleep(0.2)
|
||||
'''
|
||||
|
||||
|
||||
async def live_run(port, mode, hold_s=10.0, seconds=16.0, max_w=LIVE_MAX_W):
|
||||
"""Poll a real HTTP meter through the real transport and drive the detector."""
|
||||
ingest = P1Ingest(phases=1, max_age_s=30)
|
||||
wd = FreezeWatchdog(FreezeWatchdogConfig(hold_s=hold_s))
|
||||
t = tuning(max_w)
|
||||
target, i_w, sat = 0.0, 0.0, 0
|
||||
fired_at, polls, worst_unchanged, worst_cmd = None, 0, 0.0, 0.0
|
||||
async with aiohttp.ClientSession() as session:
|
||||
src = HomeWizardLocalSource(session, ingest, "127.0.0.1", port=port,
|
||||
poll_s=1.0)
|
||||
start = time.monotonic()
|
||||
while time.monotonic() - start < seconds:
|
||||
if await src.poll_once():
|
||||
polls += 1
|
||||
grid = ingest.net_w
|
||||
d = compute(prev_w=target, grid_w=grid, actual_w=target,
|
||||
tuning=t, sat_count=sat, i_w=i_w)
|
||||
target, i_w, sat = d.target_w, d.i_w, d.sat_count
|
||||
worst_unchanged = max(worst_unchanged, src.unchanged_s or 0.0)
|
||||
worst_cmd = max(worst_cmd, abs(target))
|
||||
if wd.evaluate(src.unchanged_s, target, max_w,
|
||||
datetime.now(timezone.utc)) and fired_at is None:
|
||||
fired_at = time.monotonic() - start
|
||||
await asyncio.sleep(1.0)
|
||||
return fired_at, polls, worst_unchanged, worst_cmd
|
||||
|
||||
|
||||
def with_server(argv, port, fn):
|
||||
proc = subprocess.Popen([sys.executable, "-c"] + argv,
|
||||
stdout=subprocess.DEVNULL, stderr=subprocess.PIPE)
|
||||
try:
|
||||
deadline = time.monotonic() + 10
|
||||
while time.monotonic() < deadline:
|
||||
try:
|
||||
import socket
|
||||
with socket.create_connection(("127.0.0.1", port), 0.3):
|
||||
break
|
||||
except OSError:
|
||||
time.sleep(0.1)
|
||||
else:
|
||||
raise RuntimeError("the fake meter never came up")
|
||||
return fn()
|
||||
finally:
|
||||
proc.kill()
|
||||
proc.wait()
|
||||
|
||||
|
||||
hw = find_hwsim()
|
||||
print(f"frozen meter over HTTP - using {'the rig hwsim at ' + str(hw) if hw else 'the local stub'}")
|
||||
if hw:
|
||||
def argv_for(mode):
|
||||
return [HWSIM_DRIVER, "8791" if mode == "freeze" else "8792", mode,
|
||||
str(hw.parent)]
|
||||
else:
|
||||
def argv_for(mode):
|
||||
return [STUB, "8791" if mode == "freeze" else "8792",
|
||||
"frozen" if mode == "freeze" else "moving"]
|
||||
|
||||
fired, polls, unch, cmd = with_server(
|
||||
argv_for("freeze"), 8791,
|
||||
lambda: asyncio.run(live_run(8791, "freeze")))
|
||||
print(f" freeze: {polls} polls, worst unchanged {unch:.1f} s, "
|
||||
f"worst |command| {cmd:.0f} W, alarm at "
|
||||
f"{'never' if fired is None else f'{fired:.1f} s'}")
|
||||
check("the transport really polled a live server", polls >= 10)
|
||||
check("a frozen meter raises the alarm", fired is not None)
|
||||
check("...and only after the hold, not on the first railed poll",
|
||||
fired is None or fired >= 10.0)
|
||||
|
||||
fired2, polls2, unch2, cmd2 = with_server(
|
||||
argv_for("moving"), 8792,
|
||||
lambda: asyncio.run(live_run(8792, "moving")))
|
||||
print(f" moving: {polls2} polls, worst unchanged {unch2:.1f} s, "
|
||||
f"worst |command| {cmd2:.0f} W, alarm at "
|
||||
f"{'never' if fired2 is None else f'{fired2:.1f} s'}")
|
||||
check("the moving meter also drove the command to the rail", cmd2 >= rail_w(LIVE_MAX_W))
|
||||
check("a REAL railed condition against a live meter stays silent", fired2 is None)
|
||||
check("...because the meter kept moving", unch2 < 10.0)
|
||||
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
# 4. the wiring, because a correct detector nobody calls is not a detector
|
||||
# --------------------------------------------------------------------------- #
|
||||
# ⚠️ EVERYTHING ABOVE PASSES WITH `app/freeze.py` IMPORTED BY NOTHING. That is
|
||||
# the shape of defect this project keeps finding: the mechanism is right, the
|
||||
# suite is green, and the shipped path never reaches it. So the real
|
||||
# `Controller.cycle()` is driven here, against the real arbiter and the real
|
||||
# control law, with a stand-in transport that reports `unchanged_s` the way
|
||||
# HomeWizardLocalSource does - and the assertion is on the SERVICE CALL that
|
||||
# leaves the process, not on the watchdog's own flag.
|
||||
print("the wiring - Controller.cycle() actually raises the notification")
|
||||
|
||||
|
||||
class _Store:
|
||||
data: dict = {}
|
||||
|
||||
def set(self, *a):
|
||||
pass
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
class _Pub:
|
||||
enabled = False
|
||||
|
||||
def publish(self, *a, **k):
|
||||
pass
|
||||
|
||||
def close(self):
|
||||
pass
|
||||
|
||||
|
||||
class _Hass:
|
||||
def __init__(self, grid):
|
||||
self.grid = grid
|
||||
self.calls = []
|
||||
self.writes = []
|
||||
# The plant tracks the command instantly, as in test_loop.py. Without
|
||||
# it the saturation freeze pins the command short of the rail and the
|
||||
# runaway under test never happens - which would have made this a check
|
||||
# that passes for the wrong reason.
|
||||
self.batt = 0.0
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
|
||||
async def number(self, entity, invert=False):
|
||||
return {"sensor.grid": self.grid, "sensor.soc": 50.0,
|
||||
"sensor.batt": self.batt}.get(entity)
|
||||
|
||||
async def set_number(self, entity, value):
|
||||
self.writes.append(float(value))
|
||||
self.batt = float(value)
|
||||
return True
|
||||
|
||||
async def call(self, domain, service, data):
|
||||
self.calls.append((domain, service, data))
|
||||
return True
|
||||
|
||||
|
||||
class _Source:
|
||||
"""Only the attribute the controller reads. Duck-typed like the real one."""
|
||||
|
||||
def __init__(self, unchanged_s):
|
||||
self.unchanged_s = unchanged_s
|
||||
|
||||
|
||||
def wired(unchanged_s, grid, cycles=60, **over):
|
||||
async def go():
|
||||
hass = _Hass(grid)
|
||||
c = Controller(dict(
|
||||
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": LIVE_MAX_W, "gain": 0.6,
|
||||
"slew_w": 1000, "deadband_w": 15, "target_grid_w": -10,
|
||||
"step_w": 10, "heartbeat_s": 10, "stale_input_s": 15},
|
||||
**over), hass, _Store(), _Pub(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
c.p1_source = _Source(unchanged_s)
|
||||
for _ in range(cycles):
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
return hass, c
|
||||
return asyncio.run(go())
|
||||
|
||||
|
||||
hass_f, ctl_f = wired(3600.0, 4000.0)
|
||||
# ⚠️ FILTERED BY notification_id, NOT BY SERVICE, since SAFETY-03. This add-on
|
||||
# now raises MORE THAN ONE kind of persistent notification, and the scenarios
|
||||
# below drive a command to the rail on purpose - which is a winding loop, which
|
||||
# legitimately raises the output-clamp alarm too. A bare `svc == "create"` test
|
||||
# therefore counts a DIFFERENT guard's alarm as this one's, which is exactly the
|
||||
# conflation SAFETY-03's second acceptance criterion exists to forbid. Keying on
|
||||
# the id is what makes "this detector said nothing" mean it.
|
||||
FROZEN_ID = "goodwe_meter_frozen"
|
||||
|
||||
|
||||
def frozen_notes(hass):
|
||||
return [d for dom, svc, d in hass.calls
|
||||
if (dom, svc) == ("persistent_notification", "create")
|
||||
and d.get("notification_id") == FROZEN_ID]
|
||||
|
||||
|
||||
notes = frozen_notes(hass_f)
|
||||
# The status row lives behind `p1_enabled`, which is what a homewizard_local
|
||||
# install has. Flipped here rather than plumbing a whole P1 transport in - the
|
||||
# row's own content is what is under test.
|
||||
ctl_f.p1_enabled = True
|
||||
rows = [c for c in ctl_f.checks() if "METER MAY BE FROZEN" in c["text"]]
|
||||
print(f" frozen at +4000 W: command ran to {ctl_f.target:.0f} W, "
|
||||
f"{len(notes)} notification(s), {len(rows)} red status row(s)")
|
||||
check("the shipped cycle() raises exactly one HA notification", len(notes) == 1)
|
||||
check("...with a fixed notification_id so repeats replace, not stack",
|
||||
notes and notes[0].get("notification_id") == "goodwe_meter_frozen")
|
||||
check("...and it says the controller is still running",
|
||||
bool(notes) and "STILL RUNNING" in notes[0]["message"])
|
||||
check("the status page carries a failed row saying so",
|
||||
len(rows) == 1 and not rows[0]["ok"] and not rows[0]["warn"])
|
||||
check("the event log names it", any("METER FROZEN" in e for e in ctl_f.events))
|
||||
# ⚠️ NOTIFY, NOT TRIP. If a later cut turns this into a trip it must come here
|
||||
# and change this expectation deliberately, not discover it in the field.
|
||||
check("and it does NOT command 0 W - this cut is an alarm only",
|
||||
abs(ctl_f.target) >= rail_w(LIVE_MAX_W))
|
||||
|
||||
hass_n, ctl_n = wired(3600.0, -14.2)
|
||||
check("wired up, TEL-05's converged case still raises nothing",
|
||||
not frozen_notes(hass_n))
|
||||
hass_m, ctl_m = wired(2.0, 8000.0)
|
||||
check("wired up, a real railed load against a moving meter raises nothing",
|
||||
not frozen_notes(hass_m)
|
||||
and abs(ctl_m.target) >= rail_w(LIVE_MAX_W))
|
||||
check("an uncovered transport (no unchanged_s) raises nothing, and says so",
|
||||
not frozen_notes(wired(None, 4000.0)[0]))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
sys.exit(1)
|
||||
print("all checks passed")
|
||||
@@ -26,9 +26,15 @@ def check(name, cond):
|
||||
|
||||
def base(**over):
|
||||
"""A configuration that must start. Everything else is this, spoilt."""
|
||||
# ⚠️ The maintenance rates are named EXPLICITLY, at the values config.yaml
|
||||
# ships (MAINT-04). They are not decoration: with the key absent, rule 6
|
||||
# falls back to main.py's 2500 W, which against this 2000 W ceiling is a
|
||||
# genuine refusal - so a base() without them would be a config that does
|
||||
# not start, and every check below would be measuring the wrong thing.
|
||||
o = {"setpoint_entity": "number.goodwe_setpoint", "max_w": 2000,
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off"}
|
||||
"meter_source": "off",
|
||||
"maintenance_charge_w": 2000, "maintenance_discharge_w": 2000}
|
||||
o.update(over)
|
||||
return o
|
||||
|
||||
@@ -151,6 +157,170 @@ check("with meter_source off the number governs nothing and is not refused",
|
||||
check("the constant is the firmware's, not a rounded guess",
|
||||
FIRMWARE_INGEST_VETO_S == 30.0)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("6. a maintenance charge the ceiling can actually accommodate (MAINT-04)")
|
||||
# ⚠️ THE SHIPPED BUG. config.yaml shipped max_w 2000 against
|
||||
# maintenance_charge_w 2500, so the cheap-window shaping asked for hi=-2500
|
||||
# against the supervised lo=-2000 - lo > hi, arbiter clause 3, 0 W. Maintenance
|
||||
# silently never charged in a cheap window on a default install.
|
||||
p = validate_startup_config(base(max_w=2000, maintenance_charge_w=2500),
|
||||
-5000, 5000)
|
||||
check("maintenance_charge_w above max_w is refused", len(p) == 1)
|
||||
check("...and the message names the charge rate", why(p, "2500"))
|
||||
check("...and the ceiling", why(p, "2000"))
|
||||
check("...and says which one wins", why(p, "THE CEILING WINS"))
|
||||
# ⚠️ Equality is REACHABLE, not a near miss: lo=-2000, hi=-2000 is the single
|
||||
# point -2000 W. Refusing it would be exactly the trivia that gets a validator
|
||||
# deleted, and it is the boundary the rule is written `>` for.
|
||||
check("maintenance_charge_w exactly at max_w starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_charge_w=2000),
|
||||
-5000, 5000) == [])
|
||||
check("below it starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_charge_w=1500),
|
||||
-5000, 5000) == [])
|
||||
# Not scoped to maintenance_enabled: the pair is contradictory either way, and
|
||||
# scoping would leave the trap armed for the one action - ticking the box - that
|
||||
# cannot be expected to change what a charge rate means.
|
||||
check("...and it is refused with maintenance_enabled off, as shipped",
|
||||
why(validate_startup_config(
|
||||
base(max_w=2000, maintenance_charge_w=2500,
|
||||
maintenance_enabled=False), -5000, 5000), "THE CEILING WINS"))
|
||||
|
||||
# ⚠️ THE SIBLING, CHECKED RATHER THAN ASSUMED. The shaping is NOT symmetric:
|
||||
# drain files Claim.set at P_MAINTENANCE and owns the actuator, so the ceiling
|
||||
# CLAMPS it (+2000 W) instead of contradicting it, and the arbiter's explain()
|
||||
# names the clamp every cycle. Loud, and it still moves energy - so warned, not
|
||||
# refused. If someone later "fixes the asymmetry" by making this a refusal,
|
||||
# this check goes red and they have to justify it.
|
||||
check("maintenance_discharge_w above max_w WARNS but starts",
|
||||
validate_startup_config(base(max_w=2000, maintenance_discharge_w=2500),
|
||||
-5000, 5000) == [])
|
||||
|
||||
# The demonstration the rule is derived from, asserted rather than described.
|
||||
from app.arbiter import ( # noqa: E402
|
||||
Claim, P_LOOP, P_MAINTENANCE, P_MAINT_SHAPE, P_SAFETY, resolve,
|
||||
)
|
||||
|
||||
def _charge(max_w, charge_w):
|
||||
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-charge_w,
|
||||
reason="cheap-window charge"),
|
||||
Claim.set("loop", P_LOOP, 500.0, "grid")])
|
||||
|
||||
def _drain(max_w, disch_w):
|
||||
return resolve([Claim.limit("supervised", P_SAFETY, -max_w, max_w, "max_w"),
|
||||
Claim.set("maintenance", P_MAINTENANCE, disch_w, "drain"),
|
||||
Claim.set("loop", P_LOOP, 500.0, "grid")])
|
||||
|
||||
r = _charge(2000, 2500)
|
||||
check("arbiter: the refused pair really does emit 0 W",
|
||||
r.target_w == 0.0 and r.contradiction)
|
||||
r = _charge(2000, 2000)
|
||||
check("arbiter: the permitted equality really does charge",
|
||||
r.target_w == -2000.0 and not r.contradiction)
|
||||
r = _charge(3000, 2500)
|
||||
check("arbiter: raising max_w above the rate charges at the rate",
|
||||
r.target_w == -2500.0 and not r.contradiction)
|
||||
r = _drain(2000, 2500)
|
||||
check("arbiter: the drain SET is clamped, not contradicted",
|
||||
r.target_w == 2000.0 and not r.contradiction)
|
||||
check("...and the clamp names itself, which is why it is not refused",
|
||||
"supervised" in (r.bound_by or "") and "limited by" in r.explain())
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the SHIPPED defaults must pass the rule they are governed by (AC3)")
|
||||
# ⚠️ Shipping a default the validator refuses would be worse than the bug it
|
||||
# refuses. Read config.yaml itself rather than a transcription of it - a
|
||||
# transcription is what lets the two drift apart silently. Regex, not PyYAML:
|
||||
# the add-on image has no PyYAML (Dockerfile installs py3-aiohttp/py3-paho-mqtt
|
||||
# only) and a check that skips on ImportError is not a check.
|
||||
import os # noqa: E402
|
||||
import re # noqa: E402
|
||||
|
||||
_CFG = os.path.join(os.path.dirname(os.path.abspath(__file__)), "config.yaml")
|
||||
with open(_CFG, encoding="utf-8") as _fh:
|
||||
_txt = _fh.read()
|
||||
_shipped = {k: float(v) for k, v in re.findall(
|
||||
r"^ (max_w|maintenance_charge_w|maintenance_discharge_w|sign_disagree_w): "
|
||||
r"(-?\d+(?:\.\d+)?)\s*$", _txt, re.M)}
|
||||
check("config.yaml really was read (all four defaults found)",
|
||||
set(_shipped) == {"max_w", "maintenance_charge_w",
|
||||
"maintenance_discharge_w", "sign_disagree_w"})
|
||||
check(f"the shipped defaults are accepted {_shipped}",
|
||||
validate_startup_config(base(**_shipped), -5000, 5000) == [])
|
||||
check("...and the shipped charge rate is at or under the shipped ceiling",
|
||||
_shipped["maintenance_charge_w"] <= _shipped["max_w"])
|
||||
check("...and the shipped discharge rate too, so it warns about nothing",
|
||||
_shipped["maintenance_discharge_w"] <= _shipped["max_w"])
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("the KNOWN cross-file default divergence, pinned rather than commented")
|
||||
# ⚠️ WHAT THIS GUARDS, AND WHY IT ASSERTS THE BUG RATHER THAN THE FIX.
|
||||
# config.yaml and validate.py now default maintenance_charge_w to 2000, while
|
||||
# main.py's two `opts.get(..., 2500)` fallbacks and MaintConfig's dataclass
|
||||
# default still say 2500. So an options dict with the key ABSENT is ACCEPTED by
|
||||
# rule 6 at 2000 and then built by main.py at 2500 - which is a contradiction:
|
||||
#
|
||||
# validate_startup_config -> [] (accepted)
|
||||
# MaintConfig().charge_w -> 2500.0
|
||||
# arbiter -> 0.0 W, contradiction=True
|
||||
#
|
||||
# That is the bug rule 6 exists to catch, passing rule 6. It is unreachable on a
|
||||
# Supervisor install (every key is always supplied from config.yaml) but fully
|
||||
# reachable from sim/inject.py and from tests - which is exactly where anyone
|
||||
# debugging maintenance works.
|
||||
#
|
||||
# The fix is ONE SOURCE OF TRUTH for option defaults. That is a bigger change
|
||||
# than this ticket and it lands in main.py, which another ticket is live in - so
|
||||
# the divergence is RECORDED here instead of closed. The check therefore passes
|
||||
# on the mismatch and FAILS when either side moves, in EITHER direction:
|
||||
#
|
||||
# - config.yaml moves -> FAIL: re-decide what the fallback should be
|
||||
# - main.py is fixed to match -> FAIL: the divergence is gone, DELETE this
|
||||
# check and the ⚠️ block in validate.py
|
||||
#
|
||||
# A comment cannot do that, and "a comment where a check belonged" is this
|
||||
# repo's most repeated defect.
|
||||
_APP = os.path.join(os.path.dirname(os.path.abspath(__file__)), "app")
|
||||
|
||||
def _read(*parts):
|
||||
with open(os.path.join(*parts), encoding="utf-8") as fh:
|
||||
return fh.read()
|
||||
|
||||
# Every literal fallback for this key in main.py, whatever the call shape.
|
||||
_main_falls = [float(m) for m in re.findall(
|
||||
r'\.get\(\s*"maintenance_charge_w"\s*,\s*(-?\d+(?:\.\d+)?)\s*\)',
|
||||
_read(_APP, "main.py"))]
|
||||
# ...and MaintConfig's own dataclass default, which is the one that bites when
|
||||
# main.py is bypassed entirely (a Maintenance built straight from defaults).
|
||||
_dc_falls = [float(m) for m in re.findall(
|
||||
r"^\s*charge_w:\s*float\s*=\s*(-?\d+(?:\.\d+)?)\s*$",
|
||||
_read(_APP, "maintenance.py"), re.M)]
|
||||
|
||||
check(f"main.py's fallbacks are still found and still 2500 {_main_falls}",
|
||||
len(_main_falls) == 2 and set(_main_falls) == {2500.0})
|
||||
check(f"MaintConfig's default is still found and still 2500 {_dc_falls}",
|
||||
len(_dc_falls) == 1 and set(_dc_falls) == {2500.0})
|
||||
check(f"...and config.yaml still ships 2000, so the divergence is UNCHANGED "
|
||||
f"(shipped {_shipped['maintenance_charge_w']:.0f}, code 2500)",
|
||||
_shipped["maintenance_charge_w"] == 2000.0)
|
||||
|
||||
# ⚠️ And the consequence itself, through the REAL code rather than through the
|
||||
# numbers above - so that if someone "fixes" this by changing a literal without
|
||||
# understanding it, the thing that goes red is the behaviour, not the transcript.
|
||||
from app.maintenance import MaintConfig # noqa: E402
|
||||
|
||||
_absent = {k: v for k, v in base().items() if k != "maintenance_charge_w"}
|
||||
_built = MaintConfig().charge_w
|
||||
check("with the key ABSENT the validator accepts...",
|
||||
validate_startup_config(_absent, -5000, 5000) == [])
|
||||
check(f"...while the code would build {_built:.0f} W against a "
|
||||
f"{_absent['max_w']:.0f} W ceiling...", _built > _absent["max_w"])
|
||||
_r = _charge(_absent["max_w"], _built)
|
||||
check("...which the arbiter resolves to 0 W as a contradiction - the hole, "
|
||||
"asserted so it cannot widen unnoticed",
|
||||
_r.target_w == 0.0 and _r.contradiction)
|
||||
|
||||
# --------------------------------------------------------------------------- #
|
||||
print("max_w must be a positive magnitude")
|
||||
# Schema-blocked on a real install, but validate_startup_config() is also
|
||||
@@ -168,7 +338,8 @@ check("...and the message explains it would read as a trip, not a mistake",
|
||||
# threshold the ceiling can actually reach, and the interaction gets its own
|
||||
# check below.
|
||||
check("the smallest sane max_w still starts",
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5), -5000, 5000) == [])
|
||||
validate_startup_config(base(max_w=1, sign_disagree_w=0.5,
|
||||
maintenance_charge_w=1), -5000, 5000) == [])
|
||||
check("...but that same 1 W ceiling with the DEFAULT sign threshold is refused",
|
||||
why(validate_startup_config(base(max_w=1), -5000, 5000), "never fire"))
|
||||
|
||||
|
||||
@@ -13,7 +13,9 @@ table-driven half: boundaries, timers, the latch, and the arming gate.
|
||||
import sys
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.watchdog import SignWatchdog, SignWatchdogConfig
|
||||
from app.watchdog import (
|
||||
SignWatchdog, SignWatchdogConfig, loop_is_following,
|
||||
)
|
||||
|
||||
fails = []
|
||||
T0 = datetime(2026, 8, 20, 15, 0, 0, tzinfo=timezone.utc)
|
||||
@@ -143,13 +145,113 @@ check("300 W under a 2000 W ceiling is accepted", p == [])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 2000},
|
||||
-5000, 5000)
|
||||
check("a threshold AT max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
p = validate_startup_config({**base, "max_w": 500, "sign_disagree_w": 3000},
|
||||
-5000, 5000)
|
||||
# ⚠️ maintenance_charge_w is named here only to keep this case about the SIGN
|
||||
# rule. MAINT-04 added a second rule against the same ceiling, and a 500 W
|
||||
# max_w is also below the 2000 W shipped maintenance charge - so without this
|
||||
# the dict is refused twice, for two correct but different reasons, and the
|
||||
# `len(p) == 1` below would be measuring the interaction rather than this rule.
|
||||
p = validate_startup_config({**base, "max_w": 500, "sign_disagree_w": 3000,
|
||||
"maintenance_charge_w": 500}, -5000, 5000)
|
||||
check("a threshold above max_w is refused", len(p) == 1 and "never fire" in p[0])
|
||||
p = validate_startup_config({**base, "max_w": 2000, "sign_disagree_w": 1999},
|
||||
-5000, 5000)
|
||||
check("one watt under the ceiling is reachable, so accepted", p == [])
|
||||
|
||||
print()
|
||||
print("the arming gate, derived from the REAL arbiter")
|
||||
# ⚠️ THIS IS THE DECISION THE WHOLE TICKET TURNS ON, and until now it was
|
||||
# asserted in three comment blocks and verified by nothing: every other case in
|
||||
# this file passes `following` in as a literal. What has to hold is that the
|
||||
# expression in main.py - loop won AND the emitted value points the way the loop
|
||||
# asked AND is no larger - is never True for a resolution the loop did not
|
||||
# actually get. So run real claims through the real resolve() and derive it.
|
||||
from app.arbiter import ( # noqa: E402
|
||||
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY, Claim, resolve,
|
||||
)
|
||||
|
||||
|
||||
def following_from(claims, asked):
|
||||
"""THE SHIPPED gate, not a copy of it.
|
||||
|
||||
⚠️ This used to transcribe main.py's expression with a comment saying
|
||||
"keep the two in step", which is exactly the arrangement that does not keep
|
||||
two things in step. Measured: editing the shipped gate alone to
|
||||
`winner in ("loop", "peak")` left this suite - including the P_PEAK row below,
|
||||
whose entire job is to catch that edit - completely green, while the watchdog
|
||||
went blind for the duration of every peak event. Import it or the P_PEAK
|
||||
assertion is decoration.
|
||||
"""
|
||||
r = resolve(claims)
|
||||
return r, loop_is_following(r, asked)
|
||||
|
||||
|
||||
MAXW = Claim.limit("supervised", P_SAFETY, -2000, 2000, "max_w")
|
||||
DEV = Claim.limit("device", P_SAFETY, -5000, 5000, "rating")
|
||||
|
||||
# name, claims, what the loop asked, expected `following`
|
||||
TABLE = [
|
||||
("the loop alone, unopposed",
|
||||
[Claim.set("loop", P_LOOP, 900)], 900, True),
|
||||
("the loop bound by max_w - reduced, not redirected",
|
||||
[Claim.set("loop", P_LOOP, 4000), MAXW], 4000, True),
|
||||
("charging, bound by max_w on the other side",
|
||||
[Claim.set("loop", P_LOOP, -4000), MAXW], -4000, True),
|
||||
("maintenance owns the setpoint outright",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("maintenance", P_MAINTENANCE, -2500, "charge"), MAXW], 900, False),
|
||||
("maintenance charge-only clamps the loop to 0 W",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=0.0, reason="charge-only"),
|
||||
MAXW], 900, False),
|
||||
# ⚠️ THE CASE `winner == \"loop\"` ALONE WOULD HAVE GOT WRONG. 1500 W, not
|
||||
# the default 2500 W: at max_w 2000 a -2500 hi against a -2000 lo is an
|
||||
# arbiter contradiction, not a charge - see main.py.
|
||||
("cheap-window charge REDIRECTS the loop while it still 'wins'",
|
||||
[Claim.set("loop", P_LOOP, 500),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-1500, reason="cheap-window"),
|
||||
MAXW], 500, False),
|
||||
("...and the contradiction at the shipped defaults is not following either",
|
||||
[Claim.set("loop", P_LOOP, 500),
|
||||
Claim.limit("maintenance", P_MAINT_SHAPE, hi=-2500, reason="cheap-window"),
|
||||
MAXW], 500, False),
|
||||
("a lo limit RAISES the magnitude without flipping the sign",
|
||||
[Claim.set("loop", P_LOOP, 200),
|
||||
Claim.limit("floor", P_SAFETY, lo=800), MAXW], 200, False),
|
||||
("a safety stop wins outright",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("safety", P_SAFETY, 0.0, "stopped"), MAXW], 900, False),
|
||||
("no claims at all - the arbiter's own failsafe",
|
||||
[MAXW, DEV], None, False),
|
||||
("the loop asked for zero",
|
||||
[Claim.set("loop", P_LOOP, 0.0), MAXW], 0.0, False),
|
||||
# The forward hazard, asserted as it stands TODAY rather than as it should
|
||||
# be. When peak shaving lands, these expectations are what have to change.
|
||||
("peak shaving at P_PEAK disarms the gate (loop_is_following's forward hazard)",
|
||||
[Claim.set("loop", P_LOOP, 900),
|
||||
Claim.set("peak", P_PEAK, 1800, "shaving"), MAXW], 900, False),
|
||||
# ⚠️ AND THE ROW ABOVE CANNOT DETECT A WIDENED GATE ON ITS OWN, which was
|
||||
# found by trying it: with the shipped gate edited to
|
||||
# `winner in ("loop", "peak")` that case STILL comes out False, because peak
|
||||
# shaving asked for MORE than the loop and the magnitude term rejects it
|
||||
# anyway. The winner term is masked. This row isolates it - a peak claim
|
||||
# smaller than the loop's ask and pointing the same way, so `winner` is the
|
||||
# only term that can decide - and it is what actually turns red if the gate
|
||||
# is widened without anyone revisiting the hazard.
|
||||
("...and with peak BELOW the loop's ask, only the winner term separates them",
|
||||
[Claim.set("loop", P_LOOP, 1800),
|
||||
Claim.set("peak", P_PEAK, 900, "shaving"), MAXW], 1800, False),
|
||||
]
|
||||
for name, claims, asked, expect in TABLE:
|
||||
r, got = following_from(claims, asked)
|
||||
check(f"{name} -> following={expect}", got is expect)
|
||||
if got is not expect:
|
||||
print(f" resolution was {r.explain()!r}")
|
||||
|
||||
# And the gate is never True when the loop did not win, whatever else is going on.
|
||||
check("no configuration above arms the gate without the loop winning",
|
||||
all(not following_from(c, a)[1]
|
||||
for _, c, a, _ in TABLE if following_from(c, a)[0].winner != "loop"))
|
||||
|
||||
print()
|
||||
print("end to end: the trip is COMMAND ZERO, not alarm-only")
|
||||
# ⚠️ THE FAULT INJECTED HERE IS A NEGATIVE GAIN, and that is not a contrivance -
|
||||
@@ -172,6 +274,16 @@ from app.main import Controller # noqa: E402
|
||||
class _Hass:
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
self.calls = []
|
||||
|
||||
# ⚠️ ADDED FOR SAFETY-03, AND THE REASON IS WORTH READING. The e2e below
|
||||
# runs a DELIBERATELY INVERTED loop (gain -0.6) into a steady 2000 W import,
|
||||
# which is a loop that winds straight into the rail - so the output-clamp
|
||||
# alarm fires here, and the stub not having `call` is how that was
|
||||
# discovered. This scenario is now a second, independent witness that the
|
||||
# clamp alarm sees a real winding loop; test_clamp.py asserts it explicitly.
|
||||
async def call(self, domain, service, data):
|
||||
self.calls.append((domain, service, data))
|
||||
|
||||
async def limits(self, entity):
|
||||
return (-5000.0, 5000.0, 1.0)
|
||||
@@ -237,10 +349,155 @@ check("the status page says so in words",
|
||||
any("SIGN-DISAGREEMENT FAILSAFE" in c["text"] for c in ctrl.checks()))
|
||||
check("the banner leads with it",
|
||||
"FAILSAFE" in ctrl.status_payload()["banner"])
|
||||
check("MQTT reports the failsafe state", ctrl.sign_wd.tripped)
|
||||
check("it stays at 0 W on later cycles too",
|
||||
hass.writes[-1] == 0.0 and hass.writes.count(0.0) >= 1)
|
||||
|
||||
# ⚠️ THIS USED TO BE `check("MQTT reports the failsafe state", ctrl.sign_wd.tripped)`
|
||||
# which restates the assertion three lines above and never touches the payload.
|
||||
# The `status: "failsafe"` value was shipped untested. Capture what publish()
|
||||
# actually hands the broker.
|
||||
published = {}
|
||||
ctrl.mqtt = type("P", (), {"enabled": True,
|
||||
"publish": lambda _s, v: published.update(v),
|
||||
"close": lambda _s: None})()
|
||||
ctrl.publish()
|
||||
check("MQTT's controller-status sensor reports 'failsafe'",
|
||||
published.get("status") == "failsafe")
|
||||
ctrl.sign_wd.reset()
|
||||
ctrl.publish()
|
||||
check("...and goes back to 'running' once cleared",
|
||||
published.get("status") == "running")
|
||||
|
||||
|
||||
print()
|
||||
print("the latch survives a restart - it is the only thing between a tripped")
|
||||
print("controller and the first thing an operator will try")
|
||||
# ⚠️ THE BLOCKER THIS FILE MISSED FIRST TIME ROUND. `auto` is persisted and
|
||||
# `tripped` was not, so reconstructing a Controller against the same Store -
|
||||
# which is exactly what a container restart does - came back armed, into the
|
||||
# fault, with no operator involved: tripped=False, banner NOT READY, and it
|
||||
# resumed commanding -1000 then -2000 W before re-tripping 180 s later.
|
||||
|
||||
|
||||
class _MemStore:
|
||||
"""A Store that keeps its dict across "restarts", like the real file does."""
|
||||
|
||||
def __init__(self):
|
||||
self.data = {"phase": "idle", "sign_tripped": False, "sign_reason": ""}
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def get_time(self, *a):
|
||||
return None
|
||||
|
||||
|
||||
async def _restart():
|
||||
shared = _MemStore()
|
||||
hass1 = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
a = Controller(opts, hass1, shared, _P(), stop=asyncio.Event())
|
||||
a.auto = True
|
||||
a.dev_min, a.dev_max = -5000.0, 5000.0
|
||||
for _ in range(12):
|
||||
await a.read_inputs()
|
||||
await a.cycle()
|
||||
await asyncio.sleep(0.25)
|
||||
|
||||
# The restart. Same options, same store, brand new Controller and Hass.
|
||||
hass2 = _Hass()
|
||||
b = Controller(opts, hass2, shared, _P(), stop=asyncio.Event())
|
||||
b.auto = True
|
||||
b.dev_min, b.dev_max = -5000.0, 5000.0
|
||||
for _ in range(6):
|
||||
await b.read_inputs()
|
||||
await b.cycle()
|
||||
await asyncio.sleep(0.05)
|
||||
return a, b, shared, hass2
|
||||
|
||||
|
||||
pre, post, store, hass2 = asyncio.run(_restart())
|
||||
check("it tripped before the restart", pre.sign_wd.tripped)
|
||||
check("the trip reached the store", store.data["sign_tripped"] is True)
|
||||
check("...with the reason beside it, so the operator is told why",
|
||||
"SIGN_DISAGREEMENT" in store.data["sign_reason"])
|
||||
check("the new Controller comes back TRIPPED", post.sign_wd.tripped)
|
||||
check("...and says why, restored rather than re-detected",
|
||||
"SIGN_DISAGREEMENT" in post.sign_wd.reason)
|
||||
check("...commands 0 W from its very first cycle", post.target == 0.0)
|
||||
check("...and never commanded anything else after the restart",
|
||||
hass2.writes != [] and set(hass2.writes) == {0.0})
|
||||
check("the banner still leads with the failsafe",
|
||||
"FAILSAFE" in post.status_payload()["banner"])
|
||||
# ⚠️ TWO PRESSES, and the first one must NOT clear it. `auto` is True while
|
||||
# tripped, so the first press stops control; only the transition back to True
|
||||
# clears. That is the documented behaviour and it is worth an assertion, because
|
||||
# a one-press clear would be reachable by an operator who never read the banner.
|
||||
asyncio.run(post.handle_action("auto_toggle")) # -> stopped
|
||||
check("pressing stop does not clear the failsafe",
|
||||
post.sign_wd.tripped and store.data["sign_tripped"] is True)
|
||||
asyncio.run(post.handle_action("auto_toggle")) # -> started
|
||||
check("pressing start DOES clear it, and clears the store with it",
|
||||
not post.sign_wd.tripped and store.data["sign_tripped"] is False
|
||||
and store.data["sign_reason"] == "")
|
||||
# One more restart from the cleared store, to prove the clear persisted too.
|
||||
fresh = Controller({"setpoint_entity": "number.sp", "meter_source": "off"},
|
||||
_Hass(), store, _P(), stop=asyncio.Event())
|
||||
check("...so the next restart comes back armed and untripped, as it should",
|
||||
not fresh.sign_wd.tripped)
|
||||
|
||||
# ⚠️ THE WRITE ORDERING IS AN INVARIANT, SO IT GETS AN ASSERTION. main.py writes
|
||||
# `sign_reason` and THEN `sign_tripped`, each one its own `save()`, so that a
|
||||
# process that dies between the two leaves a reason nothing reads - harmless -
|
||||
# rather than a latch with no explanation for the operator who has to decide
|
||||
# whether to clear it. Documented reasoning is not enforcement: swapping those two
|
||||
# lines used to pass every check in this file.
|
||||
#
|
||||
# The death is modelled as the second write raising. In the field it is a power
|
||||
# cut or a container kill (Store.save() swallows OSError rather than raising), so
|
||||
# what is asserted here is the PROPERTY - what survives on disk - not the
|
||||
# mechanism.
|
||||
|
||||
|
||||
class _CrashOnFlag(_MemStore):
|
||||
def set(self, k, v):
|
||||
if k == "sign_tripped" and v:
|
||||
raise RuntimeError("power cut, mid-trip")
|
||||
super().set(k, v)
|
||||
|
||||
|
||||
async def _crash_mid_write():
|
||||
store = _CrashOnFlag()
|
||||
hass = _Hass()
|
||||
opts = {"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
|
||||
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
|
||||
"meter_source": "off", "max_w": 2000, "gain": -0.6,
|
||||
"sign_disagree_w": 300, "sign_disagree_s": 1, "auto_start": True}
|
||||
c = Controller(opts, hass, store, _P(), stop=asyncio.Event())
|
||||
c.auto = True
|
||||
c.dev_min, c.dev_max = -5000.0, 5000.0
|
||||
died = False
|
||||
for _ in range(12):
|
||||
try:
|
||||
await c.read_inputs()
|
||||
await c.cycle()
|
||||
except RuntimeError:
|
||||
died = True
|
||||
break
|
||||
await asyncio.sleep(0.25)
|
||||
return store, died
|
||||
|
||||
|
||||
crashed_store, died = asyncio.run(_crash_mid_write())
|
||||
check("the second write is the one that sets the flag", died)
|
||||
check("a crash between the two writes leaves the REASON on disk",
|
||||
"SIGN_DISAGREEMENT" in crashed_store.data.get("sign_reason", ""))
|
||||
check("...and never a latch with nothing to explain it",
|
||||
not crashed_store.data.get("sign_tripped"))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: {', '.join(fails)}")
|
||||
|
||||
Reference in New Issue
Block a user