Compare commits

...
18 Commits
Author SHA1 Message Date
admin 1b6f16dba2 Deploy 0.17.0 to master (#186) 2026-10-11 01:37:01 +02:00
admin e36565fe39 Merge pull request #185: Release 0.17.0
infra-pin / fresh (push) Successful in 2s
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 1s
2026-10-11 00:58:29 +02:00
goodwe-review 808ec04dc4 REL-0.17.0 review: CHANGELOG wording fixes
checks / unit (pull_request) Successful in 35m16s
infra-pin / fresh (pull_request) Successful in 2s
SAFETY-107 row names the tested base; MAINT-17 says code reading only;
SAFETY-105 figure is from a simulation; SAFETY-97 edge is 175 W; the
maintenance note cites MAINT-14 and MAINT-15; SAFETY-108 "about 15 s".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 00:21:39 +02:00
glenn schrooyenandClaude Opus 5.5 35432ce065 Release 0.17.0
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 2s
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 23:29:13 +02:00
adminandClaude Opus 5.5 580c200527 Merge pull request #184: MAINT-15 the balancing hold ends on time with no SoC reading
infra-pin / fresh (push) Successful in 1s
Reviewed at 35b2a69; CI run 1238 green.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 01:38:29 +02:00
adminandClaude Opus 5.5 35b2a699de MAINT-15 round 2: in-repo differential check, full-hold with-reading check
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 00:42:01 +02:00
adminandClaude Opus 5.5 cd1bf2a694 MAINT-15: the balancing hold ends on time with no SoC reading
checks / unit (pull_request) Successful in 35m22s
infra-pin / fresh (pull_request) Successful in 1s
HOLD's time check moves into Maintenance._hold(), used by step() and
_no_soc(). A hold that loses its SoC now ends at hold_min, writes
last_completed and logs the same COMPLETE line. The 15 min HOLD line says
the hold still ends at its normal time. Behaviour with a reading is
unchanged (differential trace against db9e231).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 23:56:29 +02:00
adminandClaude Opus 5.5 db9e2315d1 SAFETY-107: a refusal held under another writer is learned once (#183)
infra-pin / fresh (push) Successful in 1s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 04:29:47 +02:00
adminandClaude Opus 5.5 848140c29f SAFETY-107 review: test a writer that turns round on a dead pack; say when rule 3 applies
checks / unit (pull_request) Successful in 35m22s
infra-pin / fresh (pull_request) Successful in 2s
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 03:52:39 +02:00
glenn schrooyenandClaude Opus 5.5 d12228d986 SAFETY-107: a refusal held under another writer is learned once
checks / unit (pull_request) Successful in 35m8s
infra-pin / fresh (pull_request) Successful in 2s
At one inverter SAFETY-52's "another writer" end tested target != loop_w.
A held refusal makes the loop ask 0 W, so any binding claim (maintenance
charge, peak guard, trade) ended it every cycle, and compute() learned it
again in the same cycle: "BATTERY REFUSES" / "ENDED: another writer" each
second on the rig. Now the held refusal is judged afresh against the
writer's ask (compute() gets the same inputs as before); it ends only if
compute() no longer finds it. Commands unchanged: 300-seed differential
trace against release/1.0, N=1 and N=2, every command and refusal state
identical. DECISIONS/SAFETY-107.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-09 03:03:06 +02:00
admin bf3ac7998c MAINT-14: maintenance with no SoC reading: charge still times out, drain holds at 0 W (#182)
infra-pin / fresh (push) Successful in 2s
2026-10-08 22:50:52 +02:00
admin df154a26d1 Deploy 0.16.0 to master (#179) 2026-10-08 01:43:37 +02:00
admin 21599938ea Merge pull request 'Deploy 0.15.0 to master' (#174) from deploy-0.15.0 into master
Deploy 0.15.0 to master (#174)
2026-10-05 10:17:38 +02:00
admin 3a54b253cb Merge pull request 'Deploy 0.14.0 to master' (#170) from deploy-0.14.0 into master
Deploy 0.14.0 to master (#170)
2026-10-03 12:32:16 +02:00
admin 8b9680fc35 Merge pull request 'Deploy 0.13.0 to master' (#166) from deploy-0.13.0 into master
Reviewed-on: #166
2026-10-02 15:26:46 +02:00
admin 3ce18708b6 PKG-18: ship 0.12.0 to master, so TEL-12's pv_entities can reach an installed 0.11.0 (#118) 2026-09-24 23:22:34 +02:00
adminandClaude Opus 5 78acb558ff PKG-17: ship 0.11.0 to master, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1 (#115)
master is what the Home Assistant Supervisor clones, and the Supervisor
compares config.yaml version strings - so 0.11.0 could not be offered to an
installed 0.10.1 without this bump reaching master.

Carries SAFETY-56 (#112), TEL-11 (#113), the CI-9 follow-up (#102) and SEC-2's
docs/RELEASE.md (#108), by way of the 0.11.0 cut (#114).

NOT A FAST-FORWARD. master was not an ancestor of release/1.0: 0f14c2a, the
pre-SEC-2 direct push, exists only on master. Its tree is the same object as
the merge base b0b24e5 (c1fef26), so it carries no content delta, and
`git merge-tree --write-tree` over the two branches returns a tree bit-identical
to cccb2fa's own (6670502). This merge commit therefore contributes exactly
release/1.0's tree - master synthesises nothing.

Reviewed as the release decision, not a re-review of content. Verified from the
remote: slug goodwe_controller and every identity key unchanged (cross-checked
against the live box's Supervisor export), version 0.10.1 -> 0.11.0, and the
green is this PR's own - run 828 / job 1953, path checks.yml@refs/pull/115/head,
PRNUM 115, GRADED refs/pull/115/head merged into master, run_attempt 1, 31 test
files all passing in 8m01s of real work.

predeploy_check.py re-run against the owner's current options (exported
2026-09-24 20:02, 75 keys, pv_entity unset): CLEARED, exit 0. That retires the
stale-2026-09-07-export warning in the pull request body. Option surface
75 -> 76 with only pv_entity added, str? defaulting to "", no key removed, no
default moved, no rule added to validate.py - no SystemExit(78) on this hop.

Merging is not installing. No tag is cut here and `ha store reload` /
`ha addons update` have not been run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 20:28:35 +02:00
glenn schrooyenandClaude Opus 5 0f14c2a5de PKG-16: ship 0.10.1 to master, so the Supervisor can offer SAFETY-57's fix
master is what Home Assistant clones. SAFETY-57 fixed a deadlock that parked
the reference install's battery for ~13 minutes while the site exported
2.4 kW, and the Supervisor compares config.yaml version strings - so the fix
could not reach an installed 0.10.0 without this bump reaching master.

Brings SAFETY-57 (#104) and the 0.10.1 cut (#105). master was a strict
ancestor; no conflict was possible.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:54:29 +02:00
11 changed files with 856 additions and 29 deletions
+44
View File
@@ -1,5 +1,49 @@
# Changelog
## 0.17.0
**A minor bump: changed behaviour, and no option changes.** No option was
added, removed or renamed, and no default changed (83 options). Options you
saved work as before. The changes below apply with one inverter or two, unless
a line says "Two inverters".
**Maintenance with no battery level.** When the battery level is missing,
battery maintenance now ends on its own time limits instead of waiting for the
level to come back (MAINT-14, MAINT-15). You do not need to change any option.
Contents of this release, in merge order since 0.16.0 (`451729c`):
| | |
|---|---|
| `b527e99` | Two inverters: after a drain ends, the other battery no longer swings on old readings. In the test, it held steady for 23 s where 0.16.0 moved it by 720 W ([[SAFETY-103]]) |
| `8a17711` | A full battery that stops at 98 or 99 % no longer counts as a failed charge. After 60 min with no new high, the charge counts as done; a charge that truly fails now waits 7 days and shows one notice ([[MAINT-13]]) |
| `bf3ac79` | With no battery level, a maintenance charge still ends at its time limit and a drain waits at 0 W. The log no longer repeats a line every second ([[MAINT-14]]) |
| `db9e231` | One inverter: when maintenance charges a battery that is already full, the log no longer repeats "The battery refuses to give power" every second. In the test, 1 line in 16 min where the code before this fix wrote about 1,700 in 15 min; the power does not change ([[SAFETY-107]]) |
| `580c200` | The balancing hold after a charge now ends on time when the battery level is missing. Before, it waited until the level came back ([[MAINT-15]]) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- A battery whose reading at rest is beyond about ±175 W is still not caught when it refuses ([[SAFETY-97]]).
- The peak guard can still back off near the end of a 15-minute period when a meter reading is late, by less than 30 s ([[SAFETY-99]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
- Two inverters: a drain that starts during a big step in house use can send the other battery to full power, and about 1 kW goes to the grid for about 10 s ([[SAFETY-104]]).
- Two inverters: when a battery comes back during a maintenance charge, the grid can step by several kW at once ([[SAFETY-101]]).
- Two inverters: when a battery drops out during a solar surplus, the others can swing by up to 1.5 kW in a simulation ([[SAFETY-105]]).
- Two inverters: after a drain ends, a change in house use can go unanswered for about 9 s, because some readings are old ([[SAFETY-106]]).
- Two inverters: when one battery's level is missing, both batteries are held at 0 W, and for about 15 s the last command stays on ([[SAFETY-108]]).
- Two inverters: if one battery's level stays missing for 12 h, the other battery's cycle can be marked failed, with a 7-day wait and a notice, though it is healthy. This comes from reading the code; it has not been seen on a site ([[MAINT-17]]).
- One inverter: after a link drop, the battery's own safety stop to 0 W can be taken as a refusal, and the site stays at 0 W for up to 15 min ([[SAFETY-102]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.16.0
**A minor bump: changed behaviour, no option added or removed, and one default
@@ -58,10 +58,7 @@ allows discharge.
## What this does not cover
- **HOLD with no SoC** still holds 0 W and, as before, does not end while the
reading is missing: its time check sits behind the same early return. A HOLD
needs no level to end, so this is a candidate follow-up, not part of this fix. It is card MAINT-15. The "no battery level" line in
HOLD says only that the hold waits for the level.
- **HOLD with no SoC**: closed by MAINT-15 (`MAINT-15-hold-ends-without-soc.md`).
- It does not tell the operator why the reading is missing (sensor, register,
link). It does not reuse the stale-input gate; it is the cycle's own rule.
- The charge itself is still driven by the control loop, which has its own
@@ -0,0 +1,47 @@
# MAINT-15 - the balancing hold ends on time with no SoC reading
**Status: for review.** Tests: `test_maint15.py`. No option added.
**The fault.** `step()` sent every tick with no SoC to `_no_soc()`, and for
HOLD that returned 0 W without the time check. A hold that lost its reading
never ended: `last_completed` was never written and the next due date never
moved. Harmless for power (0 W), but the cycle was stuck. This was left open
in MAINT-14.
## Rule
1. **HOLD ends at `hold_min` whether or not there is a reading.** One helper,
`Maintenance._hold()`, holds the time check and is used by both paths. When
the time is up it writes `last_completed`, goes IDLE and logs the same
"cycle COMPLETE" line. Before the time is up it commands 0 W as before.
2. **Text.** The 15-min "no battery level" line in HOLD now reads "The hold
still ends at its normal time." Still once per episode.
## Why
HOLD is reached only after the charge counted as done. Every entry into HOLD
is in `step()` or `_no_soc()` and follows a charge that reached the target,
stalled near full (MAINT-13) or timed out near full (MAINT-13/14). Nothing else
sets the phase to HOLD (`_enter(HOLD` has four call sites, all after a done
charge). The hold is a wait for the BMS to balance; it never needed the level.
So a hold that ends with no reading is a completed cycle. The "cycle COMPLETE"
line is true without a reading: it names minutes of hold, not a level.
## Cost
- If the level was lost during the hold, the cycle is recorded as complete
without anyone seeing the final level. The charge had counted as done, so this
is the same trust MAINT-14 already gives a charge that ends with no reading.
## What this does not cover
- It does not check that the pack is still full at the end of the hold.
- It does not say why the reading was lost.
- With a reading, nothing changes. `test_maint15.py` section 7 compares the new
HOLD tick by tick with a frozen copy of the release/1.0 HOLD branch (phase,
setpoint, owner, events, `last_completed`) at four `hold_min` values. A wider
trace of the whole cycle (800 seeded runs against db9e231) was run outside the
repo; its script and log are kept under `scratch/MAINT-15/` of the dev
workspace, not in this repository.
- A state file written by an older version with `phase: hold` loads and ends on
time; the file is not changed in format.
@@ -0,0 +1,96 @@
# SAFETY-107 - a refusal held under another writer is learned once
**Status: for review.** Tests: `test_safety107.py`. One inverter only; nothing
changes at N>1 (SAFETY-73's unit refusal has no "another writer" end).
**The defect** (MAINT-13 F5, MAINT-14 "seen again"). A full pack under a
maintenance charge in a cheap window takes no charge. At N=1 the action log then
showed "BATTERY REFUSES asked -2500 W ..." and "BATTERY REFUSES ENDED: another
writer" every cycle: 548 + 548 lines in 15 min on the MAINT-13 rig head,
652 + 651 in 12 min on its base, 33 + 32 in 60 s in MAINT-14's c2b. The 40-line
log flooded and the hint under the buttons changed every second, so the
MAINT-13 notice was gone at once.
**Cause** (`main.py`, the SAFETY-52 block before `compute()`). The end tested
`self.target != self.loop_w`: the wire differs from the loop's ask. A held
refusal makes the loop ask 0 W, so any claim that binds (the maintenance
charge's `hi`, the peak guard's `lo`, a trade's SET) differs from it on every
cycle. The refusal was ended against the same writer it had been learned
against. `sat_count` is not reset by that end, so `compute()` learned the same
refusal again in the same cycle. Nothing about the battery or the wire had
changed; only the log and the hint did.
**Other writers.** The same flap comes from any writer that holds the wire
while the loop is refused, as long as the evidence lasts: a trade (a SET at
P_ARBITRAGE) into a full pack, and the peak guard over an empty pack: 335
refusal lines in 15 min each at a 5 s meter (`test_safety107.py` part 2, run on
release/1.0).
A maintenance drain or hold does not flap: its SET resets `sat_count` each cycle.
**The rule** (`_refusal_update()`, `rejudged`). When another writer held the
wire, the held refusal is judged afresh: `compute()` gets `refused=0` and no
probe, exactly as before the change. Then:
1. it finds the same refusal against that writer's ask: the same episode
continues, with no line and no hint. The probe clock restarts, as it did on
the old end and start: a probe is the loop's ask, and it is not on the wire
while another writer is;
2. it does not: the refusal ends, logged "another writer", or "the battery
gives power" when the reading shows it (it was "another writer" before);
3. it finds the other direction: end, then a new start, as before. In
practice 2 comes first: SAFETY-94's evidence restarts when the ask changes
sign, so a writer that turns round ends the refusal at once and the other
way is learned ~12 cycles later (`test_safety107.py` part 3e).
**Why this rule.** The end now means what SAFETY-52 meant by it: the refusal no
longer describes what is on the wire, judged by the same test that learns it.
`compute()` sees the same inputs as before and the state after each cycle is
the same (`batt_refused`, `batt_refused_at`), so every command is unchanged.
Keeping the held refusal into `compute()` instead (mutation M5) would also
stop the lines, but it holds the loop at 0 W where the old law let it ask past
a writer's limit, which changes commands; it also removes SAFETY-52's
owner-decided "another writer" exit.
**Evidence.**
- Differential trace (`goodwe/scratch/SAFETY-107/probe/trace.py`, not in this
repo; the real Controller in the CI image, release/1.0 bf3ac79 against this
tree): 300 seeds, N=1 (153) and
N=2 (147), 1/2/5 s meter, full/empty/dead/healthy battery windows, a stepping
house, maintenance charge with the cheap window opening and closing, P1 and
the peak guard, trade windows, stop/start; 427 680 cycles, 294 seeds with a
refusal held. Every command, site target, integrator, `sat_count`, refusal
state and reason is identical. Refusal lines: 100 748 before, 2 188 after.
- The card's case: 1 line in 15 min at N=1 and N=2, 1/2/5 s meter, house
importing or exporting (release/1.0: 335-1 753 at N=1; N=2 was already 1).
**Mutations** (`tools/mutation_run.sh` on purged copies; reds in
test_safety107 / test_refusal / test_refusal_units; trace = seeds of 300 whose
commands differ from release/1.0):
| | mutation | reds | trace |
|---|---|---|---|
| M1 | `now == rejudged` -> `False` (every such cycle ends: the old flap) | 26 / 0 / 0 | 0 |
| M2 | `rejudged` always 0 (another writer never ends it) | 5 / 1 / 2 | 29 |
| M3 | the probe clock is not restarted on a continued episode | 1 / 0 / 0 | 2 |
| M4 | a probe may open while rejudged | 0 / 0 / 0 | 0 |
| M5 | the held refusal goes into `compute()` while rejudged | 2 / 1 / 2 | 27 |
| M6 | an end while rejudged always says "another writer" | 1 / 0 / 0 | 0 |
M4 is equivalent: a probe matters only if `compute()` engages in that call,
which needs `SETTLE_CYCLES` saturated against the writer, and each of those
cycles restarted the clock. The line stays because it states the rule.
**Cost.** None in power. A takeover by a different writer while the battery
still refuses is logged as an end and, ~12 cycles later, a new start against
that writer (3 lines for the episode, `test_safety107.py` part 3a).
**Not covered.**
- A perfectly flat reading under a writer. The stale-reading gate trips, stops
the site and seeds the refusal (SAFETY-52 decision 3). After the stop the
writer's ask returns fresh, `compute()` has no saturation history against it,
so the refusal ends at the first cycle and the next trip seeds it again: 2
lines per gate cycle (29 in 15 min, house exporting), the same as release/1.0.
The gate cycle itself (0 W, then the writer's ask) is the cause; stopping it
changes commands. None of the rig runs showed it: real readings move.
- At N=1 a refusal shapes only the loop. A writer above it still asks the
battery; at N>1 SAFETY-73's P_SAFETY claim binds every writer.
+5 -1
View File
@@ -605,6 +605,10 @@ still moving towards the request, such as one turning from charging to
giving (SAFETY-94). "Gives" is counted from what the battery's reading shows
at rest, which the add-on learns after two quiet minutes and keeps: some
inverters show about -100 W at rest (SAFETY-97).
While another task sets the power, such as a maintenance charge, the peak
guard or a trade, the refusal stays as long as the battery still refuses that
task's request. It is logged once, and the 200 W test waits until control sets
the power again (SAFETY-107).
**With two or more inverters** the same rule works per inverter. An inverter
whose battery gives less than 100 W for 12 cycles, and at least 22 s, while
@@ -618,7 +622,7 @@ If the battery refuses to give power while its level reads above its “Battery
cut-out level”, the log adds one warning ending in `REFUSES_ABOVE_CUT_OUT`: check that setting.
A battery that refuses is not reported as *not delivering*.
*For installers:* SAFETY-52 and SAFETY-73. The event log reads
*For installers:* SAFETY-52, SAFETY-73 and SAFETY-107. The event log reads
`BATTERY REFUSES …` and `BATTERY REFUSES ENDED …` (with the inverter's name at
N>1), and the INFO line ends in `BATTERY_REFUSES`.
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures and
+31 -7
View File
@@ -1279,9 +1279,26 @@ class Controller:
_LOG.info("The battery refusal ends, control asks for power again: %s.",
why)
def _refusal_update(self, decision, asked_w, batt_w, probe) -> None:
"""Follow `compute()`'s carried refused direction, and say so."""
def _refusal_update(self, decision, asked_w, batt_w, probe,
rejudged: int = 0) -> None:
"""Follow `compute()`'s carried refused direction, and say so.
`rejudged`: the refusal held while another writer had the wire, so
`compute()` judged it afresh against that writer's ask (SAFETY-107).
"""
now = decision.refused or 0
if rejudged:
if now == rejudged:
# Still refused against the ask on the wire: the same episode.
# The probe clock restarts, as it did when this was an end and
# a new start: a probe is the loop's ask, and it is not on the
# wire while another writer is.
self.batt_refused_at = self._now_mono
return
gave = (rejudged * (batt_w - self._site_idle_w())
>= _ctl.PROBE_ANSWER_W)
self._refusal_end("the battery gives power" if gave
else "another writer")
if now and not self.batt_refused:
self._refusal_start(now, f"asked {asked_w:+.0f} W, the battery "
f"gave {batt_w:+.0f} W for "
@@ -4973,11 +4990,15 @@ class Controller:
if trade_was and not mode_trade:
self._reseed_run_edge(claims)
# SAFETY-52: another writer overrode the loop, so a refusal learned
# against the loop's own ask no longer describes the wire. A gap
# against the loop's own ask may no longer describe the wire. A gap
# (`loop_w` None: blind or stopped) keeps it: the stale-reading stop
# is what seeds it, and dropping it there restarts the ~70 s cycle.
# SAFETY-107: it ends only if compute() no longer finds it against
# that writer's ask (`_refusal_update()`). A held refusal makes the
# loop ask 0 W, so any claim that binds differs from it every cycle.
rejudged = 0
if self.loop_w is not None and self.target != self.loop_w:
self._refusal_end("another writer")
rejudged = self.batt_refused
# SAFETY-96: a battery that dropped out of the split leaves the
# loop's start point (SAFETY-93's own if its charge ended too).
self._reseed_drop(_live96)
@@ -4986,7 +5007,8 @@ class Controller:
# SAFETY-95: then a drain that ended, last (it reads the start
# the others left).
self._reseed_drain_end(maint_results, _live96)
probe = self._refusal_probe()
# No probe while it is judged afresh (the loop does not hold the wire).
probe = False if rejudged else self._refusal_probe()
if len(self.inverters) > 1:
probe = any(_probing.values())
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
@@ -5029,7 +5051,8 @@ class Controller:
# limit already closes an empty battery's discharge end.
# SAFETY-73: at N>1 the site law holds 0 W only while every
# unit refuses the same way. Otherwise None, the old law.
refused=self.batt_refused if len(self.inverters) == 1
refused=(0 if rejudged else self.batt_refused)
if len(self.inverters) == 1
else self._site_refused(),
probe=probe,
# SAFETY-94: at N=1 the engage also needs the reading to have
@@ -5055,7 +5078,8 @@ class Controller:
self.loop_w = decision.target_w
self._loop_decision = decision
if len(self.inverters) == 1:
self._refusal_update(decision, loop_prev, site_batt, probe)
self._refusal_update(decision, loop_prev, site_batt, probe,
rejudged)
# --- TEL-10 ------------------------------------------------------
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
# THE CARD IS. `self.i_w` is carried between cycles and published
+22 -13
View File
@@ -541,11 +541,29 @@ class Maintenance:
events.append(msg)
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
def _hold(self, now: datetime, events: list) -> MaintResult:
"""HOLD for one tick, with or without a SoC reading (MAINT-15).
HOLD needs no level to end: it is reached only after the charge counted
as done (MAINT-13/14), so its end is a time check and nothing else.
"""
elapsed = self._elapsed_min(now)
if elapsed >= self.cfg.hold_min:
self.store.set_time("last_completed", now)
self._enter(IDLE, now, events,
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
"- handing back to the loop")
return MaintResult(IDLE, False, None, False, events)
# 0 W, not "do nothing": commanding zero is what stops the loop
# pulling the pack straight back down the moment it is full, which
# is exactly when the BMS needs it parked at the top.
return MaintResult(HOLD, True, 0.0, False, events)
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
events: list) -> MaintResult:
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
HOLD stays at 0 W and ends at its normal time (MAINT-15). DRAIN holds at 0 W, like HOLD, and its 12 h
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
time is a failure, except when the last SoC seen was within
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
@@ -563,7 +581,7 @@ class Maintenance:
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
>= NOSOC_NOTE_MIN * 60):
self._nosoc_said = True
tail = ("The hold waits for the level to come back."
tail = ("The hold still ends at its normal time."
if phase == HOLD else
f"The time limit of the {phase} still applies.")
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
@@ -571,7 +589,7 @@ class Maintenance:
_LOG.warning("%s", msg)
events.append(msg)
if phase == HOLD:
return MaintResult(HOLD, True, 0.0, False, events)
return self._hold(now, events)
elapsed = self._elapsed_min(now)
if phase == DRAIN:
if elapsed > DRAIN_TIMEOUT_MIN:
@@ -736,16 +754,7 @@ class Maintenance:
return MaintResult(CHARGE, False, None, True, events)
if phase == HOLD:
if elapsed >= self.cfg.hold_min:
self.store.set_time("last_completed", now)
self._enter(IDLE, now, events,
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
"- handing back to the loop")
return MaintResult(IDLE, False, None, False, events)
# 0 W, not "do nothing": commanding zero is what stops the loop
# pulling the pack straight back down the moment it is full, which
# is exactly when the BMS needs it parked at the top.
return MaintResult(HOLD, True, 0.0, False, events)
return self._hold(now, events)
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
events += self.abort(now, f"unknown phase {phase!r}")
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller
version: "0.16.0"
version: "0.17.0"
slug: goodwe_controller
description: >-
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
+3 -3
View File
@@ -245,8 +245,8 @@ m = in_charge()
m.tick(T0 + MIN, 100.0)
_, _, _, ev = run(m, T0 + 2 * MIN, 30, None)
note = [e for e in ev if "no battery level for" in e]
check("HOLD: the line exists and claims no time limit",
len(note) == 1 and "time limit" not in note[0] and "waits" in note[0])
check("HOLD: the line exists and says the hold ends at its normal time (MAINT-15)",
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0])
m = in_charge()
_, _, _, ev = run(m, T0, 30, None)
check("charge keeps its wording", any("time limit of the charge" in e for e in ev))
@@ -268,7 +268,7 @@ _, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
_, _, _, ev = run(m, out[1] + MIN, 30, None)
check("charge done with no SoC, then HOLD with no SoC: a new episode, so the "
"HOLD line is said", out[0].phase == HOLD
and sum("hold waits" in e for e in ev) == 1)
and sum("normal time" in e for e in ev) == 1)
print("6. restart while the SoC is missing")
with tempfile.TemporaryDirectory() as d:
+299
View File
@@ -0,0 +1,299 @@
"""MAINT-15: the HOLD ends on time with no SoC reading.
`python3 test_maint15.py`
Graded here: a HOLD that loses its SoC (at the start, mid-hold, just before
hold_min) ends on time, writes last_completed and says the COMPLETE line; SoC
back mid-hold changes nothing; HOLD stays 0 W; one pack's loss leaves the other
pack alone; a restart in HOLD with no SoC and an old state file.
See DECISIONS/MAINT-15-hold-ends-without-soc.md.
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
"""
import os
import sys
import tempfile
from datetime import datetime, timedelta, timezone
from app.maintenance import (
CHARGE, DRAIN, HOLD, IDLE, NOSOC_NOTE_MIN, MaintConfig, Maintenance,
)
from app.store import DEFAULTS, Store
UTC = timezone.utc
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
discharge_w=2000, charge_w=2000, soc_floor=11,
soc_target=100, hold_min=120)
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
MIN = timedelta(minutes=1)
class Mem:
def __init__(self, data=None):
self.data = dict(DEFAULTS, **(data or {}))
def set(self, k, v):
self.data[k] = v
def set_time(self, k, when):
self.data[k] = when.astimezone(UTC).isoformat() if when else None
def get_time(self, k):
raw = self.data.get(k)
return datetime.fromisoformat(raw) if raw else None
def save(self):
pass
def in_drain(store=None, unit=None, at=T0):
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
m.force_start(at)
assert m.phase == DRAIN
return m
def in_charge(store=None, unit=None, at=T0):
m = in_drain(store, unit, at)
m.tick(at, 11.0)
assert m.phase == CHARGE
return m
def run(m, start, minutes, soc, gate=True, step=1):
"""Tick every `step` min; returns (last result, end time, first result that
is not the starting phase with its time, all events)."""
ph, t, res, out, ev = m.phase, start, None, None, []
for i in range(0, minutes, step):
t = start + i * MIN
s = soc(i) if callable(soc) else soc
res = m.tick(t, s, gate_open=gate)
ev += res.events
if out is None and res.phase != ph:
out = (res, t)
break
return res, start + minutes * MIN, out, ev
HOLD_MIN = CFG.hold_min
def in_hold(store=None, unit=None, at=T0):
"""A pack in HOLD that started at `at` + 1 min (charge counted as done)."""
m = in_charge(store, unit, at)
m.tick(at + MIN, 100.0)
assert m.phase == HOLD
return m
H0 = T0 + MIN # the hold's start
print("1. SoC lost in HOLD: the hold ends on time")
for label, lost_at in (("at the start", 0), ("mid-hold", 60),
("just before hold_min", HOLD_MIN - 1)):
m = in_hold()
run(m, H0, lost_at, 100.0) if lost_at else None
res, _, out, ev = run(m, H0 + lost_at * MIN, HOLD_MIN + 5 - lost_at, None)
check(f"lost {label}: ends at hold_min, to IDLE, not failed",
out is not None and out[0].phase == IDLE and out[0].failed == ""
and out[1] == H0 + HOLD_MIN * MIN)
check("...last_completed is written at that time",
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
check("...the same COMPLETE line, once, and no last_failed",
sum("cycle COMPLETE (120 min hold)" in e for e in ev) == 1
and m.store.get_time("last_failed") is None)
check("...the pack is idle and hands the setpoint back",
m.phase == IDLE and not out[0].owns_setpoint)
m = in_hold()
res, _, out, _ = run(m, H0, HOLD_MIN - 1, None)
check("before hold_min: still HOLD at 0 W, owned, nothing written",
out is None and res.phase == HOLD and res.owns_setpoint
and res.setpoint_w == 0.0 and m.store.get_time("last_completed") is None)
check("...the pack is not due again (next due date moved after the end)",
(run(m, H0 + (HOLD_MIN - 1) * MIN, 3, None), m.due(H0 + 130 * MIN))[1] is False)
print("2. the text")
m = in_hold()
_, _, out, ev = run(m, H0, HOLD_MIN + 5, None)
note = [e for e in ev if "no battery level for" in e]
check("one 15 min line, saying the hold ends at its normal time",
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0]
and f"{NOSOC_NOTE_MIN} min" in note[0])
check("...and the other events are the one COMPLETE line only", len(ev) == 2)
m = in_hold()
_, _, _, ev = run(m, H0, NOSOC_NOTE_MIN - 2, None)
check("under the threshold the line is not said", ev == [])
print("3. SoC comes back mid-hold")
ends = {}
for label, soc in (("no SoC", lambda i: None if i < 40 else 100.0),
("SoC the whole time", 100.0),
("a low SoC after the gap", lambda i: None if i < 40 else 55.0)):
m = in_hold()
res, _, out, ev = run(m, H0, HOLD_MIN + 5, soc)
ends[label] = (out[1], m.store.get_time("last_completed")) if out else None
check(f"{label}: ends at hold_min", out is not None
and out[1] == H0 + HOLD_MIN * MIN)
check("...the end time is the same with or without the gap",
len(set(ends.values())) == 1)
m = in_hold()
run(m, H0, 40, None)
res, _, out, _ = run(m, H0 + 40 * MIN, 30, 100.0)
check("back mid-hold: still HOLD at 0 W until the time is up",
out is None and res.phase == HOLD and res.setpoint_w == 0.0)
print("4. restart in HOLD with no SoC")
with tempfile.TemporaryDirectory() as d:
path = os.path.join(d, "state.json")
m = Maintenance(CFG, Store(path))
m.force_start(T0)
m.tick(T0, 11.0)
m.tick(H0, 100.0)
run(m, H0, 50, None)
m2 = Maintenance(CFG, Store(path))
r = m2.tick(H0 + 51 * MIN, None)
check("a fresh process reads HOLD and holds 0 W", m2.phase == HOLD
and r.phase == HOLD and r.owns_setpoint and r.setpoint_w == 0.0)
res, _, out, _ = run(m2, H0 + 52 * MIN, HOLD_MIN, None)
check("...and the hold ends at hold_min from the hold start, not the restart",
out and out[0].phase == IDLE and out[1] == H0 + HOLD_MIN * MIN
and m2.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
import json
old = {"phase": "hold", "phase_started": H0.isoformat(),
"last_completed": None, "last_start_attempt": None, "auto": True}
p2 = os.path.join(d, "old.json")
json.dump(old, open(p2, "w"))
mo = Maintenance(CFG, Store(p2))
r = mo.tick(H0 + 10 * MIN, None)
check("an old state file in HOLD loads and holds 0 W", mo.phase == HOLD
and r.setpoint_w == 0.0)
res, _, out, _ = run(mo, H0 + 11 * MIN, HOLD_MIN, None)
check("...and ends on time, writing last_completed",
out and out[1] == H0 + HOLD_MIN * MIN
and mo.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
mr = Maintenance(CFG, Store(p2))
check("...the written file reloads as a finished cycle",
mr.phase == IDLE and mr.store.get_time("last_completed") is not None)
print("5. two packs")
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
a_ok, b_ok = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
for x in (a, a_ok):
x.force_start(T0)
x.tick(T0, 11.0)
x.tick(H0, 100.0)
# B is idle; A's hold loses its SoC (twin site: A keeps it)
same, a_end = True, None
for i in range(0, HOLD_MIN + 10):
t = H0 + i * MIN
ra = a.tick(t, None)
rb = b.tick(t, 60.0)
ra2 = a_ok.tick(t, 100.0)
rb2 = b_ok.tick(t, 60.0)
same = same and (rb.phase, rb.owns_setpoint, rb.setpoint_w) == \
(rb2.phase, rb2.owns_setpoint, rb2.setpoint_w) and b.phase == b_ok.phase
if a_end is None and a.phase == IDLE:
a_end = t
check("A loses SoC in HOLD: A ends on time (as the twin with a reading)",
a_end == H0 + HOLD_MIN * MIN and a_ok.phase == IDLE
and a.store.get_time("last_completed") == a_ok.store.get_time("last_completed"))
check("...B is the same as in the twin site where A kept its SoC", same)
# B in its own HOLD with SoC, A in HOLD without
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
a.force_start(T0); a.tick(T0, 11.0); a.tick(H0, 100.0)
b_start = H0 + 30 * MIN
b.force_start(b_start - MIN); b.tick(b_start - MIN, 11.0); b.tick(b_start, 100.0)
b_end = None
for i in range(0, HOLD_MIN + 40):
t = H0 + i * MIN
a.tick(t, None)
if t >= b_start:
b.tick(t, 100.0)
if b_end is None and b.phase == IDLE:
b_end = t
check("B (SoC present) ends at its own hold_min, A's loss changes nothing",
b_end == b_start + HOLD_MIN * MIN and a.phase == IDLE
and b.store.get_time("last_completed") == b_start + HOLD_MIN * MIN)
check("...A's end is not delayed by B", a.store.get_time("last_completed")
== H0 + HOLD_MIN * MIN)
print("6. other phases unchanged")
m = in_drain()
res, _, out, _ = run(m, T0, 60, None)
check("DRAIN with no SoC still holds 0 W and does not end", out is None
and res.phase == DRAIN and res.setpoint_w == 0.0)
m = in_charge()
res, _, out, _ = run(m, T0, 600, None)
check("CHARGE with no SoC still keeps charging", out is None
and res.phase == CHARGE and res.charge_only)
def old_hold_branch(phase_started, last_completed, now, hold_min):
"""FROZEN copy of release/1.0 (db9e231) HOLD branch of step(), with a
reading: returns (phase, owns_setpoint, setpoint_w, events,
last_completed). Kept as a reference for the differential check below."""
elapsed = (now - phase_started).total_seconds() / 60.0
if elapsed >= hold_min:
return (IDLE, False, None,
[f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
"- handing back to the loop"], now)
return (HOLD, True, 0.0, [], last_completed)
print("7. with a reading: the new HOLD against the frozen release/1.0 branch")
for hm in (0, 5, 60, 120):
cfg = MaintConfig(enabled=True, interval_days=28, start_hour=19,
discharge_w=2000, charge_w=2000, soc_floor=11,
soc_target=100, hold_min=hm)
m = Maintenance(cfg, Mem())
m.force_start(T0)
m.tick(T0, 11.0)
m.tick(H0, 100.0)
started, last, same, end = H0, None, True, None
for i in range(0, hm + 15):
t = H0 + i * MIN
if m.phase != HOLD:
break
want = old_hold_branch(started, last, t, hm)
r = m.tick(t, 100.0 - (i % 3))
got = (r.phase, r.owns_setpoint, r.setpoint_w, r.events,
m.store.get_time("last_completed"))
same = same and got == want
last = want[4]
if r.phase == IDLE:
end = t
check(f"hold_min {hm}: every tick identical (phase, owns, W, events, "
"last_completed)", same)
check("...ends at hold_min, last_completed = that tick, one COMPLETE line",
end == H0 + hm * MIN and m.store.get_time("last_completed") == end
and m.phase == IDLE)
m = in_hold()
res, _, out, ev = run(m, H0, HOLD_MIN + 5, 100.0)
check("HOLD with a reading: 0 W until the end, then IDLE at hold_min",
out is not None and out[1] == H0 + HOLD_MIN * MIN and out[0].phase == IDLE)
check("...last_completed is that tick and the COMPLETE line is said once",
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN
and ev == ["maintenance: cycle COMPLETE (120 min hold) "
"- handing back to the loop"])
print()
if fails:
print(f"{len(fails)} FAILED:")
for f in fails:
print(" -", f)
sys.exit(1)
print("all ok")
+307
View File
@@ -0,0 +1,307 @@
"""Runnable check for SAFETY-107: a refusal held while another writer has the
wire is learned once. `python3 test_safety107.py`
A full pack under a maintenance charge in a cheap window took no charge. At
one inverter SAFETY-52's "another writer" end then fired every cycle, and
compute() learned the refusal again in the same cycle: "BATTERY REFUSES" and
"BATTERY REFUSES ENDED: another writer" each second on the rig (MAINT-13 F5).
Now another writer ends a refusal only if compute(), judging it afresh
against that writer's ask, no longer finds it. DECISIONS/SAFETY-107.
Drives the REAL Controller (read_inputs + cycle) on opt11_identity's rig.
1. The card's case: 15 min of a full pack under a maintenance charge, N=1
and N=2, at a 1, 2 and 5 s meter: at most 2 refusal lines, held throughout.
2. Other writers: a trade and the peak guard over a battery that gives
nothing. One episode each, no flap.
3. A refusal still ends: a different writer really takes over, the battery
delivers again, a writer asks the other way, stop. The probe clock.
4. Not covered, pinned: a perfectly flat reading under a writer.
Mutations (MUTATION.md, purged copies) are listed in DECISIONS/SAFETY-107.
"""
import functools
import logging
import os
import sys
import tempfile
HERE = os.path.dirname(os.path.abspath(__file__))
sys.path.insert(0, HERE)
sys.path.insert(0, os.path.join(HERE, "tools"))
logging.disable(logging.WARNING)
import opt11_identity as rig # noqa: E402
import safety79_identity as s79 # noqa: E402
import app.main as app_main # noqa: E402
from app import control # noqa: E402
from app.arbiter import Claim, P_ARBITRAGE # noqa: E402
from app.main import Controller # noqa: E402
from named_absence import nth, present # noqa: E402
fails = []
QUARTER = 900.0
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def run(n=1, *, plant, house, dur=QUARTER, tick=5.0, maint=True,
cheap=lambda c, t: True, trade=lambda t: None, p1=False, cap=2500,
auto=lambda t: True):
"""Rows (t, commands, site target, loop reason, refused, refused_at,
unit refusals) and every action-log line as (t, line, hint).
`plant(u, t, cmd)` is battery u's reading. `cheap(c, t)` opens the cheap
window. `trade(t)` is a SET claim at P_ARBITRAGE added to the claim list
(a writer above the loop), or None."""
log, rows, now = [], [], [0.0]
real_power, real_tick = rig._Hass.power, rig.TICK
real_log, real_resolve, real_c = (Controller.log_event, app_main.resolve,
rig.Controller)
def power(self, u):
return float(plant(u, self.t, self.cmd[u]))
def log_event(self, msg, hint=None):
log.append((now[0], msg, hint))
return real_log(self, msg, hint)
def resolve(claims, **kw):
v = trade(now[0])
if v is not None:
claims.append(Claim.set("arbitrage", P_ARBITRAGE, v, "trade"))
return real_resolve(claims, **kw)
def before(c, t):
now[0] = t
if not getattr(c.hass, "_s107", False):
read = c.hass.number
async def number(e, invert=False):
if e == "sensor.pnow":
return 0.05 if cheap(c, c.hass.t) else 0.30
if e == "sensor.pavg":
return 0.20
return await read(e, invert)
c.hass.number, c.hass._s107 = number, True
if p1:
s79._feed(c, t)
c.auto = auto(t)
def on_cycle(c, t):
rows.append((t, tuple(c.hass.cmd[u] for u in "ab"[:n]), c.target,
c.loop_reason, c.batt_refused, c.batt_refused_at,
tuple(i.refused for i in c.inverters)))
extra = {"price_now_entity": "sensor.pnow",
"price_avg_entity": "sensor.pavg"}
if maint:
extra.update({"maintenance_enabled": True,
"maintenance_start_hour": 11,
"maintenance_charge_w": 2000})
if p1:
extra.update(s79.P1, peak_cap_w=cap)
db = os.path.join(tempfile.mkdtemp(prefix="s107-"), "tariff.db")
rig._Hass.power, rig.TICK = power, tick
Controller.log_event, app_main.resolve = log_event, resolve
rig.Controller = functools.partial(real_c, peak_db_path=db)
try:
_, c = rig.run(n, extra=extra, dur=dur, load=house,
soc=lambda u, t: 50.0, cut=lambda u, t: False,
before=before, on_cycle=on_cycle,
store=s79.store_charging(n) if maint else rig._Store())
finally:
rig._Hass.power, rig.TICK = real_power, real_tick
Controller.log_event, app_main.resolve = real_log, real_resolve
rig.Controller = real_c
return rows, log, c
def full_a(u, t, cmd):
"""A takes no charge (a full pack), its reading jittering by a few watts
as a real one does; B follows."""
return -1.0 - int(t) % 3 if u == "a" and cmd < 0 else round(cmd)
def flat_a(u, t, cmd):
"""`full_a` with a perfectly flat reading (the stale-reading gate trips)."""
return -1.0 if u == "a" and cmd < 0 else round(cmd)
def empty_a(u, t, cmd):
"""A gives nothing (an empty pack), its reading jittering by a few watts
(SAFETY-73's jitter shape, so the stale-reading gate stays out of it);
B follows."""
return -4.0 - int(t) % 3 if u == "a" and cmd >= -4.0 else round(cmd)
def lines(log, word="REFUSES"):
return [x for x in log if word in x[1]]
def ends(log):
return [x for x in log if "REFUSES ENDED" in x[1]]
def refused(r):
"""Row r holds a refusal (site at N=1, any unit at N>1)."""
return bool(r[4]) or any(r[6])
def held_from(rows):
"""True when, once learned, the refusal is held on every later row."""
first = next((k for k, r in enumerate(rows) if refused(r)), None)
return first is not None and all(refused(r) for r in rows[first:])
# ==============================================================================
print("1. the card: a full pack under a maintenance charge, 15 min")
# ==============================================================================
for n, tick, house in ((n, k, h) for n in (1, 2) for k in (1.0, 2.0, 5.0)
for h in (800.0, -1500.0)):
rows, log, c = run(n, plant=full_a, house=lambda t: house, tick=tick)
ref = lines(log)
tag = f"N={n}, {tick:.0f} s meter, house {house:+.0f} W"
print(f" {tag}: {len(ref)} refusal line(s): "
+ " / ".join(x[1][:60] for x in ref))
check(f"{tag}: at most 2 refusal lines in 15 min (rig: 548 + 548)",
1 <= len(ref) <= 2)
check(f"{tag}: no end line", not ends(log))
check(f"{tag}: learned once and held to the end", held_from(rows))
# N=1: the charge's ceiling stays on the wire. N=2: SAFETY-73 closes A
# in the refused direction, as before.
check(f"{tag}: still in its charge, the wire as before",
c.maints[0].phase == "charge"
and all(r[1][0] == (-2000.0 if n == 1 else 0.0)
for r in rows[-10:]))
# The hint under the buttons is set at most once for the refusal.
check(f"{tag}: the refusal hint is set once",
sum(1 for x in ref if x[2] is not None) == 1)
# The probe clock: while the charge holds the wire no probe is tried (the
# loop's ask is not on the wire), so the action log stays quiet.
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, dur=3600.0)
check("N=1, an hour: still one line, no probe tried under the charge",
len(lines(log)) == 1
and not any(r[3] == control.PROBING for r in rows))
# ==============================================================================
print("\n2. other writers: a trade and the peak guard, no flap")
# ==============================================================================
# A trade (a SET above the loop) asks a full pack to charge for 15 min.
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0, maint=False,
trade=lambda t: -1500.0)
print(f" trade into a full pack: {len(lines(log))} line(s)")
check("a trade into a full pack: learned once, held, no end",
len(lines(log)) == 1 and not ends(log) and held_from(rows))
# The peak guard asks an empty pack to give while the house is over the limit.
rows, log, c = run(1, plant=empty_a, house=lambda t: 4500.0, maint=False,
p1=True)
print(f" peak guard on an empty pack: {len(lines(log))} line(s), "
f"guard floor {c.peak_guard.floor_w if c.peak_guard else None}")
check("the peak guard on an empty pack: the guard holds the wire",
c.peak_guard is not None and c.peak_guard.engaged)
check("the peak guard on an empty pack: at most 2 lines, held to the end",
1 <= len(lines(log)) <= 2 and held_from(rows))
# ==============================================================================
print("\n3. a refusal still ends")
# ==============================================================================
# a. Learned by the loop on an empty pack; at 300 s a trade really takes the
# wire and asks it to give 2000 W. The refusal was learned against the
# loop's ask: it ends, then is learned against the trade, once.
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
trade=lambda t: 2000.0 if 300.0 <= t < 900.0 else None,
dur=1200.0)
e = ends(log)
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
check("a different writer takes over: the refusal ends, 'another writer'",
len(e) == 1 and "another writer" in e[0][1] and 300.0 < e[0][0] < 320.0)
check("...and is learned again against the trade, once, and held",
len(lines(log)) == 3 and held_from([r for r in rows if r[0] > 400.0]))
check("...and the loop keeps it when the trade leaves (no line)",
all(x[0] < 900.0 for x in lines(log)) and refused(nth(rows, -1)))
# The writer asks the other way, which the empty pack takes.
rows, log, _ = run(1, plant=empty_a, house=lambda t: 2000.0, maint=False,
trade=lambda t: -1500.0 if t >= 300.0 else None)
e = ends(log)
check("a writer that asks the other way ends it ('another writer')",
len(e) == 1 and "another writer" in e[0][1] and present(nth(rows, -1))
and not refused(nth(rows, -1)))
# b. The full pack starts taking charge again under the same writer.
rows, log, _ = run(1, plant=lambda u, t, cmd: (
round(cmd) if t >= 400.0 else full_a(u, t, cmd)), house=lambda t: 800.0)
e = ends(log)
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
check("the battery takes charge again: the refusal ends once, on its reading",
len(e) == 1 and "the battery gives power" in e[0][1]
and 400.0 <= e[0][0] < 430.0 and present(nth(rows, -1))
and not refused(nth(rows, -1)))
# c. Stop and start still end it.
rows, log, _ = run(1, plant=full_a, house=lambda t: 800.0,
auto=lambda t: not 500.0 <= t < 520.0)
e = ends(log)
check("stopping control still ends it", any("control stopped" in x[1]
for x in e))
# d. The probe clock. Learned under the charge; the cheap window closes when
# the refusal is 910 s old, and the loop holds the wire (a surplus, so it
# wants to charge). The first probe is a full PROBE_EVERY_S after the
# window closed, as before: never at once.
close = [None]
def window(c, t):
if close[0] is None and c.batt_refused:
close[0] = t + 910.0
return close[0] is None or t < close[0]
rows, log, _ = run(1, plant=full_a, house=lambda t: -1500.0, cheap=window,
dur=3000.0)
probes = [r[0] for r in rows if r[3] == control.PROBING]
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
print(f" window closed at {close[0]} s, first probe at "
f"{probes[0] if probes else None} s")
check("the refusal carries over to the loop with no line",
len(lines(log)) == 1 and held_from(rows))
check("the first probe after the writer left comes PROBE_EVERY_S later",
close[0] is not None and bool(probes)
and probes[0] >= close[0] + control.PROBE_EVERY_S - 10.0)
# e. A writer turns round on a dead pack with no gap. The evidence restarts
# on the new sign (SAFETY-94), so the old refusal ends at once and the
# other way is learned once, ~12 cycles later.
rows, log, _ = run(1, plant=lambda u, t, cmd: (
-2.0 - int(t) % 3 if u == "a" else round(cmd)), house=lambda t: 2000.0,
maint=False, trade=lambda t: 2000.0 if t < 300.0 else -2000.0)
e = ends(log)
print(" " + " / ".join(f"{x[0]:.0f} s {x[1][:45]}" for x in lines(log)))
check("a writer turns round on a dead pack: one end, then the other way",
len(lines(log)) == 3 and len(e) == 1 and 300.0 < e[0][0] < 400.0
and present(nth(rows, -1)) and nth(rows, -1)[4] == -1)
# ==============================================================================
print("\n4. not covered: a perfectly flat reading under a writer")
# ==============================================================================
# The stale-reading gate trips on a flat reading while the command moves,
# stops the site and seeds the refusal (SAFETY-52 decision 3). After the stop
# the writer's ask comes back fresh, compute() has no saturation history
# against it yet, so the refusal ends at the first cycle and the next trip
# seeds it again: one pair per gate cycle, as on release/1.0 (the commands
# are the same; DECISIONS/SAFETY-107 "Not covered"). Pinned so a change shows.
rows, log, _ = run(1, plant=flat_a, house=lambda t: -1500.0)
trips = len(lines(log, "STALE inverter"))
print(f" flat reading, house -1500 W: {trips} gate trips, "
f"{len(lines(log))} refusal lines in 15 min")
check("flat reading: no per-cycle flap, at most one pair per gate trip",
trips >= 1 and len(lines(log)) <= 2 * trips)
print()
if fails:
print(f"{len(fails)} FAILED: " + ", ".join(fails))
sys.exit(1)
print("all SAFETY-107 checks passed")