Commit Graph
79 Commits
Author SHA1 Message Date
glenn schrooyenandClaude ec4ba49f45 Release 0.20.1
checks / unit (pull_request) Successful in 28m19s
infra-pin / fresh (pull_request) Successful in 1s
Patch bump: OPT-36 (Leftover solar counts Cheap hours only and Solar first batteries). No option changes.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-02 17:52:41 +01:00
glenn schrooyenandClaude d2f63fe86a Release 0.20.0: version bump and CHANGELOG
checks / unit (pull_request) Successful in 24m4s
infra-pin / fresh (pull_request) Successful in 2s
config.yaml version 0.20.0 (minor; no option change) and a ## 0.20.0
CHANGELOG section that folds in the unreleased block and lists every
first-parent merge since 0.19.2 (f1c9733).

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-11-01 16:12:45 +01:00
glenn schrooyenandClaude 88ab8a50e3 SAFETY-125: a grid charge counts a late meter reading's seconds; the guard row says "over" when it is
checks / unit (pull_request) Successful in 56m44s
infra-pin / fresh (pull_request) Successful in 1s
A meter reading late near a quarter's end left seconds the projection did
not count (SAFETY-99), and charge_headroom_w() read them as room: the cheap
run (and price trading, and the N=2 maintenance charge) went back to full
power in the quarter's last seconds and the quarter could land over a banked
month peak or the cap. peakguard.charge_room_w() counts those seconds at the
held reading for the charge only; the guard's floor is unchanged.

The guard row said "idle, heading for 5 814 W, under this month's 5 413 W
peak". Over the limit at the current rate the row and the month-peak line
now say so, and that the grid charge is cut back.

Version 0.19.2, CHANGELOG, DECISIONS. test_safety125.py new; the lag pins
in test_price_run_fixes.py and test_opt20.py and the AST pin in
test_arbitrage.py follow the change (see the pull request).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-29 02:08:38 +01:00
glenn schrooyenandClaude d667f3f3a8 TARIFF-24: battery modes start the tariff task (hotfix 0.19.1)
With battery modes on, a day/night or fixed static_profile, no price feed and
arbitrage off, tariff_refresh_wanted() was false: no tariff task, no
tariff_plan, mode_runs None, so Leftover solar / Cheap hours never charged from
the grid and the Batteries screen said "No prices". packmode.enabled(opts) is
now a third term of the gate. With price_provider off the task is pure
arithmetic on static_profile, so no HTTPS call is added.

Also: version 0.19.1, CHANGELOG entry, DECISIONS note, test_tariff24.py, and a
shorter tariff_refresh_wanted() docstring (history stays in DECISIONS).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-28 01:02:32 +01:00
glenn schrooyenandClaude ae9268835f Release 0.19.0: minor bump for changed price trading behaviour
checks / unit (pull_request) Successful in 48m3s
infra-pin / fresh (pull_request) Successful in 1s
Owner chose 0.19.0 (2026-10-26) because PRICE-02 changes trading behaviour.
Version and CHANGELOG heading/first line only; no option changes.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-26 00:15:43 +01:00
glenn schrooyenandClaude f8b3e23a46 Release 0.18.3
checks / unit (pull_request) Successful in 48m2s
infra-pin / fresh (pull_request) Successful in 1s
Bump version to 0.18.3 and add the 0.18.3 CHANGELOG section: DOC-8, UX-45,
SAFETY-119, SAFETY-121, UX-46, PRICE-02. A patch bump: no option added,
removed or renamed, no default changed.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-25 16:53:30 +01:00
glenn schrooyenandClaude fd08090360 DOC-8: say EMS port, not meter bus
checks / unit (pull_request) Successful in 40m22s
infra-pin / fresh (pull_request) Successful in 1s
The add-on is wired to the inverter's RS485 port labelled EMS. Reword
README, DOCS, config description, field guide source and HTML. The HA
manufacturer string is left unchanged: test_mqtt pins it byte for byte.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-17 01:09:42 +02:00
glenn schrooyenandClaude 75f4359aac Release 0.18.2
checks / unit (pull_request) Successful in 40m23s
infra-pin / fresh (pull_request) Successful in 2s
Version bump to 0.18.2 and a CHANGELOG section for SAFETY-118 (#198).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 20:54:29 +02:00
glenn schrooyenandClaude dec8e7b69f Release 0.18.1
checks / unit (pull_request) Successful in 40m39s
infra-pin / fresh (pull_request) Successful in 2s
Version 0.18.0 -> 0.18.1 (patch, no option changes) and a closed 0.18.1 CHANGELOG section.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-16 12:08:58 +02:00
Claude e7c83d3a57 Release 0.18.0: version bump and CHANGELOG section
checks / unit (pull_request) Successful in 40m26s
infra-pin / fresh (pull_request) Successful in 1s
config.yaml version 0.17.0 -> 0.18.0 and a closed ## 0.18.0 CHANGELOG
section for OPT-17, SAFETY-112, OPT-15, MAINT-11, PRICE-01 and OPT-20.
No code change.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-15 21:37:17 +02:00
glenn schrooyenandClaude 9ac3a9d2bc PRICE-01: price_service provider, fallback chain, and the gate read from it
checks / unit (pull_request) Successful in 39m31s
infra-pin / fresh (pull_request) Successful in 1s
A new price source, `price_provider: price_service`: the owner's price server,
one fixed HTTPS host, a bearer token (new password option
`price_service_token`), wholesale energy only so markup and taxes are added as
for generic_dayahead.

The chain is server, then energy-charts, then the prices the history store
kept. A step counts only if it has a price for now. Each step down and back up
is one log line. With every source down a site plans from what it saved.

No price for now: one status row, one Home plan line and one notification, in
English and Dutch, cleared when a price returns. With this provider the
maintenance charge gate reads the provider's prices and keeps the Home
Assistant rule: the current 15-minute price is at or below today's average.

The token is hidden on the settings page, refused when missing, and taken out
of any error text. Other providers, `off` and the Home Assistant pair take the
road they always took (scripted-day probe against 0ce7d35: one line differs,
the refusal that lists the known providers). See
DECISIONS/PRICE-01-own-price-server.md.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-14 16:22:24 +02:00
glenn schrooyenandClaude Opus 5.5 9b1fa758ad OPT-17: the solar forecast can come from several entities, summed
checks / unit (pull_request) Successful in 36m13s
infra-pin / fresh (pull_request) Successful in 1s
New list options pv_forecast_entities and pv_forecast_tomorrow_entities
(same shape as pv_entities); the single-entity keys are unchanged.

- Each member is read in its own unit (Wh/kWh/MWh) in one gather and the
  day is summed. Hourly splits are merged when every member has one, else
  the total goes on the bell.
- A member missing, unavailable, stale, non-energy or bad makes that
  day's forecast unusable (no partial sum). A caution row names it by
  position; the action log names the entity once per change.
- Single key and list both set for one day: refused at start.
- A one-member list behaves exactly like the single key (test_opt17.py);
  the single-key path is byte-identical to e36565f over 24 scenarios.
- Supervisor shape measured: tools/supervisor_shape_probe.py section J.

DECISIONS/OPT-17-several-forecast-entities.md has the rules.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
2026-10-11 02:55:58 +02:00
glenn schrooyenandClaude Opus 5.5 35432ce065 Release 0.17.0
checks / unit (pull_request) Successful in 35m11s
infra-pin / fresh (pull_request) Successful in 2s
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section.
No code change, no option change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 23:29:13 +02:00
glenn schrooyenandClaude Opus 5.5 756b50ddbb Release 0.16.0
checks / unit (pull_request) Successful in 32m41s
infra-pin / fresh (pull_request) Successful in 1s
version 0.15.0 -> 0.16.0 and a closed ## 0.16.0 CHANGELOG section.
No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-07 23:25:14 +02:00
glenn schrooyenandClaude Opus 5.5 08fb1235fc Merge release/1.0 (0.15.0 + SAFETY-90) into maint-10-local-start-hour
Conflicts: main.py's maintenance import (base added CHARGE, HOLD; branch added
site_zone) - both kept. DOCS maintenance table: base's longer drain-rate row
kept, start hour row at 19 / local.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 21:51:04 +02:00
adminandClaude Opus 5.5 f01152b113 Release 0.15.0: bump version and close the CHANGELOG section
checks / unit (pull_request) Successful in 29m1s
infra-pin / fresh (pull_request) Successful in 1s
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from
SAFETY-94/97, no option change). New `## 0.15.0` section with the contents
since 0.14.0 (cf705a9 #171, 3129dae #172) and the known issues.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-05 00:48:04 +02:00
glenn schrooyenandClaude Opus 5.5 b307db1049 Release 0.14.0: version bump and changelog
checks / unit (pull_request) Successful in 27m2s
infra-pin / fresh (pull_request) Successful in 2s
Two inverters are now supported for maintenance and the peak guard
(SAFETY-91, SAFETY-93). No option changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 10:30:25 +02:00
adminandClaude Opus 5.5 28cab03947 REL-0.13.0: cut 0.13.0
checks / unit (pull_request) Successful in 25m55s
infra-pin / fresh (pull_request) Successful in 2s
Bump config.yaml version 0.12.0 -> 0.13.0 and close a ## 0.13.0
CHANGELOG section covering every merge since 0.12.0 (a45ed06), with the
known issues SAFETY-90/91/92/93/94. Option surface 77 -> 83, none removed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-02 09:04:47 +02:00
goodwe-agent 02c0a3dd7b MAINT-10: maintenance start hour in local time, default 19:00
The start hour was compared with the UTC hour, so the shipped 10 started at
12:00 in a Belgian summer. It is now read in Home Assistant's time zone
(fallback: the container's TZ, then UTC, one log line says which), and the
default moves to 19. DST: a missing hour starts at the first hour after the
jump; a repeated hour starts only in its first pass. Stored options are not
rewritten: a saved 10 now means 10:00 local (DOCS, CHANGELOG).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 22:52:05 +02:00
Claude eb10537aee OPT-11 P4: solar forecast and day plan
A Home Assistant solar forecast (Forecast.Solar, Solcast or Open-Meteo
shapes) and the add-on's own hourly house use decide, before each cheap
run, whether the sun will fill each battery before the expensive hours.
Leftover solar then buys from the grid only the shortfall; Cheap hours only
skips the part the sun covers; Solar first never grid-charges. No, stale or
failed forecast: P3 option A exactly (12 digests pinned from 5a4cdc2).

Replay (16 recorded days, forecast errors from Elia's day-ahead BE solar):
year-earlier prices P4 19.15 vs P2 19.33 / option A 19.44 / old trade 18.14;
real 2026 prices P4 29.19 vs 32.26 / 32.01 / 31.40 EUR net.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 19:29:32 +02:00
glenn schrooyenandClaude Opus 5.5 7c4c8f5c66 SAFETY-79: peak guard keeps a margin below the limit
checks / unit (pull_request) Failing after 11m34s
infra-pin / fresh (pull_request) Successful in 1s
New option peak_margin_w (default 50 W, 0-500 W). The peak guard, the
forecast checks and the maintenance charge sizing aim at
peak_cap_w - peak_margin_w; the month peak, the bill, headroom, warnings
and every notice keep the real cap. Owner decision 2026-09-28.

peak_margin_w 0 is byte-identical to ed739d4 (tools/safety79_identity.py,
test_peak_margin.py part 1). validate.py rule 12 refuses a value outside
0-500, not whole, or not below the peak limit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UBtqPrG1mDLXzTEBnhEkkV
2026-09-28 23:09:39 +02:00
Claude dev agent d69fd8fbfd OPT-11 P1: per-battery mode limits, on/off, solar order
checks / unit (pull_request) Successful in 10m59s
infra-pin / fresh (pull_request) Successful in 1s
A battery's mode is a soft unit limit (source `mode`, P_MODE 35) kept
apart from the hard limits in pre_resolve(). The allocator applies it
only while the site target is decided at or below 35 (new
Resolution.deciding_priority), so the peak floor releases it and a mode
`hi` never meets the site `lo`. At N=1 resolve() applies the same rule
to the site target after stage 2. A mode range without 0 W is dropped
as a software fault, so REFUSE_SIGN stays unreachable from a mode.

compute() gets the loop bound (sum over live units of hard limits with
modes applied), so the loop never asks for watts no battery may give
and the saturation freeze never parks on them. While charging, Leftover
solar weighs 0 so Solar first fills first. Store keys pack_use and
pack_mode per battery, set by two new /action values; Off stops and
skips maintenance with a log line. Minimal Batteries cards (EN/NL).

Off by default (battery_modes_enabled); off, commands are byte-identical
to a5dddad at N=1 and N=2 (test_modes.py part 1).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-28 18:51:29 +02:00
glenn schrooyenandClaude Opus 5.5 7559d21eda TEL-14: PV sign declared per entity (pv_invert_entities)
checks / unit (pull_request) Successful in 8m39s
Some PV entities (kWh meters, ESPHome clamps in the PV circuit) read positive
for consumption and negative for production. `pv_invert_entities` lists the
ones to flip; the flip is applied per member inside pv.total(), before the sum,
so the MQTT `pv` row and the status page carry the corrected figure. Default []
is byte-identical to 0.12.0.

Shape measured in supervisor_shape_probe.py section H (Supervisor 2026.08.0):
a parallel list validates the 0.12.0 blob unchanged and renders as its own
translated repeatable field; dicts on pv_entities refuse 0.12.0's stored
strings; a prefix is invisible syntax; a global bool cannot describe a mixed
roster. Status page marks flipped entities and cautions per entity below
-50 W, saying ADD or REMOVE. Telemetry only: control documents unchanged.

Record: DECISIONS/TEL-14-pv-sign.md (reverses TEL-11 section 2).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-25 00:25:24 +02:00
adminandClaude Opus 5.5 29ca9b5157 DOC-1: operator docs name the real P1 entity and a roster that starts
checks / unit (pull_request) Successful in 8m8s
- DOCS.md / config.yaml: the watchdog's P1 age entity is
  sensor.goodwe_p1_sample_age (device "GoodWe" + "P1 sample age", as
  app/mqtt.py announces and the live install recorded), not
  sensor.p1_sample_age_s.
- DOCS.md: the inverters: example and per-entry table carry the required
  bms_soc_floor (and capacity_kwh); config.yaml's schema comment says four
  required keys, not three.
- Field guide: marked v0.1.0/outdated; slew_w row no longer recommends the
  1000 W that SAFETY-39 now refuses. HTML regenerated; the PDF is NOT
  rebuilt (no Chrome here). README/DOCS pointers fixed.
- test_docs.py: the documented roster must pass app/validate.py and the
  schema's per-entry keys; the documented entity id must equal the id
  composed from app/mqtt.py; the wrong id may appear in no shipped doc.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 23:24:50 +02:00
glenn schrooyenandClaude Opus 5.5 1ad4d3a5bb PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0
checks / unit (pull_request) Successful in 8m5s
One runtime merge since 0.11.0 (cccb2fa): TEL-12 (#116), a new optional
list option `pv_entities` beside `pv_entity`. Option surface 76 -> 77, so
a minor bump. config.yaml version and a closed `## 0.12.0` section only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:59:44 +02:00
adminandClaude Opus 5 0ef9565071 TEL-12: several PV inverters, and one absent member is an absent TOTAL
checks / unit (pull_request) Successful in 7m59s
0.11.0 shipped `pv_entity` as a single string. The reference site's owner
reported within minutes of it going live that they have several PV inverters
and could configure one - which is ordinary for a multi-string roof, not a
property of one house. `pv_entities` is the roster and the row carries the
SITE total.

⚠️ THE HARD PART IS ABSENCE, NOT THE LIST. Three configured, one `unavailable`,
and the sum of the other two is a SMALLER NUMBER INDISTINGUISHABLE FROM A REAL
ONE. Read back by OPT-10 that says "there was less PV than there was" - the "no
irradiance" conclusion the channel exists to TEST. So `pv.total()` answers
`None` the moment any configured entity is absent: the topic carries HA's own
`None`, the entity goes to `unknown`, the recorder records a GAP. The
alternative (the partial sum beside a contributor count) was implemented and
run as mutation N1b; it loses because the MQTT row is read COLD a week later by
an attribution that would believe it, while the qualifying count would live in a
second entity with its own history. The partial information is not thrown away -
the STATUS PAGE names every entity that reported, with its watts, and every one
that did not, with its reason, because that surface is read LIVE by a human who
wants the diagnostic.

⚠️ AND THE MIRROR: a member honestly reporting 0 W is SUMMED. The test is
`is None`, never falsiness - a roster that blanked the site on a zero would
report an absence on every clear evening.

THE SURFACE IS MEASURED, NOT PREFERRED. `pv_entity` could not become a list:
tools/supervisor_shape_probe.py §G shows Supervisor 2026.08.0 answering an
0.11.0 install's stored string with `Invalid list for option 'pv_entity'`, and
deepmerge's list strategy is `override` so a `[]` default does not rescue it -
the live add-on would not start. `match(.*)?` does accept both shapes and is
rejected for a different, measured reason: it validates nothing (a string, a
list and the integer 417 all pass) and renders as a plain text box. So
`pv_entities` joins `pv_entity` and REPLACES it when set, CFG-04's rule for
`inverters:`, with a status caution saying which key won - a union would
double-count the inverter the old key still names.

STILL NOT A CONTROL INPUT. tools/tel11_pv_trace.py was extended rather than
replaced and now grades five claims over three document sets. The control hash
is UNMOVED - 846a10a5b89e… on `unset` and on `one`, on both trees - and the
roster control document is byte-identical between the two trees. 2/5 is a claim
TEL-11 could not make: with 0.11.0 as the baseline, "one entity behaves exactly
as 0.11.0 does" is a real cross-tree identity over control AND telemetry.

⚠️ TEL-11's OWN `--compare` REFUSAL HAD TO CHANGE, and that is MUTATION.md habit
24: a discriminator defined as "the baseline lacks this feature" dies on the
release that ships the feature, and dies as a false refusal.

Twelve mutations, each on a fresh purged `cp -a`, no survivors. N5 is +0 B
(`sum` -> `max`, the same three characters) and was run on a fresh copy with
`cmp` confirming the edit on disk. The fixture is three distinct NON-ZERO
contributions in two units with absence driven at EVERY position - a member
contributing 0 W could go absent without moving the sum of the rest, which is
habit 23 with a coinciding value in the arithmetic rather than in the plant.

31/31 in the CI image. Not deployable as merged: config.yaml stays at 0.11.0,
so predeploy_check.py reports a NO-OP until PKG cuts a version. A CHANGELOG
entry is wanted and deliberately not written - 11b forbids `## Unreleased` and
the bump is PKG's call; DECISIONS/TEL-12-several-pv-inverters.md is the
material it needs.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 22:13:25 +02:00
adminandClaude Opus 5 cfafdffaed PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1
checks / unit (pull_request) Successful in 8m0s
Two files, and no third. config.yaml 0.10.1 -> 0.11.0; CHANGELOG.md gains
`## 0.11.0` and three corrections to sections below it.

A MINOR BUMP, NOT A PATCH. TEL-11 adds an option - `pv_entity`, 75 keys -> 76 in
`options:` and `schema:` together - which is the same test 0.8.0, 0.9.0 and
0.10.0 were cut on. Nothing here can refuse a stored blob: the key is `str?`
with an `options:` default of "", validate.py does not mention it, no default
moved and no enum widened, so a blob that starts the add-on on 0.10.1 starts it
on 0.11.0.

THE TABLE HAS TWO ROWS AND THE WINDOW HAD FOUR MERGES. CI-9's follow-up
(9f6b9f1, `.gitea/workflows/checks.yml` only) and SEC-2 (239e120,
`docs/RELEASE.md` + README.md) are excluded under PKG-15's rule - AUDIENCE, NOT
IMPORTANCE. Neither file is under `goodwe_controller/`, neither is in the built
image, neither is in predeploy_check.py's RUNTIME tuple, and there is no version
of this add-on on which an operator can observe either. SEC-2 is the closer call
and the section argues it in full rather than asserting it: it is the more
consequential ticket of the two - it is why this release is a pull request
rather than a push to master - and it is still a procedure for whoever cuts a
release, not something the person deciding whether to press Update can act on.
Both are named in the section with pointers to PR #102 / checks.yml and PR #108
/ docs/RELEASE.md.

WHAT THE ENTRIES LET AN OPERATOR DECIDE. SAFETY-56: behaviour byte-identical
(6030175ed2ab..., reproduced in the CI image over 2390 capture reads, a 66-cell
grid stepped 120 times and six driven worlds), three surfaces named with the old
and new wording side by side - the STALE_READING line quoted onto the action log
and status page, the SAFETY-37 ERROR log line, and the readiness row that
asserted a false fact about a named entity. TEL-11: unset is byte-identical in
BOTH the control and telemetry documents, set is byte-identical in the control
document only; the three TEL-11 rows of that table were re-measured in the CI
image on this tree (control 846a10a5... twice, telemetry a443a6ce... / 4e6d1cb2...).
It is stated plainly that pv_entity is not a control input and does not change
what the loop does, and that absence publishes `unknown` rather than 0.

THREE CORRECTIONS BELOW THE NEW SECTION, WITHOUT REWRITING HISTORY. The 0.10.1
preamble said SAFETY-56 was open; the SAFETY-57 entry said its accusatory
diagnosis half was "deliberately untouched"; the 0.10.0 preamble left SAFETY-56
with no pointer while SAFETY-57 had one. All three quotations are what the
0.10.1 image actually prints and are left standing - a reader on 0.10.1 has to
recognise them - each now scoped to 0.10.1 and pointed at `## 0.11.0`.

VERIFIED. test_version_gate.py part 11 all four: 11a one contents table and the
slicer closed (302 lines under '0.11.0'), 11b 0.11.0 == config.yaml, 11c all
three RETIRED_PROVIDERS ids named - scoped to a pre-0.10.0 crossing and pointing
at `## 0.10.0`, which is where the evidence is - 11d still exactly one
`## Unreleased` below, PKG-08's, untouched. 31/31 in the CI image, checks.yml's
exact command, purged tree, `:ro`.

Not deployed and not installed. Shipping is a separate pull request from
release/1.0 into master, per docs/RELEASE.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 18:50:13 +02:00
glenn schrooyenandClaude Opus 5 07ba3433ed TEL-11: PV production stops being invisible, and stays out of the control law
checks / unit (pull_request) Successful in 8m6s
OPT-10 measured that this site's pack reaches 90 % SoC on 2 days of 16 and that
20.5 kWh of surplus left the site while the pack had room - 12.6 kWh of it with
the battery not charging at all - and could not say WHY, because PV production
is recorded NOWHERE. Three causes need three different fixes (no irradiance:
nothing to fix; a charge-power limit; the optimiser declining to charge, which
is the only software defect) and guessing between them is how an optimiser gets
tuned to solve a cloud problem. This card adds the channel. It does not do the
attribution.

AN HA ENTITY, NOT A REGISTER, AND THAT IS A PRODUCT DECISION. This add-on's
RS485 bus carries the BATTERY inverter it drives; a household's PV inverter is
normally a different box from a different vendor reporting into Home Assistant
through its own integration. `pv_entity` takes whatever `sensor.*` the site's
own PV integration provides, any brand HA can read.

POSITIVE IS PRODUCTION, AND THERE IS NO `pv_invert`. The convention is derived
rather than assumed: `meter_entity` is positive when IMPORTING and `batt_entity`
is positive when DISCHARGING (DOCS.md, Sources), both of which are "power
arriving at the house's AC bus", and production arrives there too. Those two
keys carry invert flags because they are BIPOLAR and are READ BY THE CONTROL
PATH - `inv.batt` feeds SAFETY-30's per-unit sign check and SAFETY-31's
circulating-power sensor, so a reversed sensor hands the site a plausible number
it acts on. Production is unipolar and is read by nothing: a reversed sensor
announces itself as -4 kW at noon in the very history this card creates, and a
flag would only let an installer hide it. No negative-value alarm either - a PV
inverter's own standby draw makes a small negative reading at night ordinary, so
any threshold would be a number nobody measured.

ABSENCE IS NEVER ZERO, AND "DROPPED" IS NOT ABSENT. `publish()` SKIPS a None,
which is right for `circulation` and exactly wrong here: a skipped row leaves
Home Assistant holding the last number forever and the recorder draws a FLAT
LINE through the outage, which is indistinguishable from a measurement and
manufactures the "there was no surplus" conclusion this card exists to TEST. So
the absence is published, with HA's own payload: `mqtt/const.py` declares
`PAYLOAD_NONE = "None"` and `mqtt/sensor.py` tests it BEFORE the numeric branch,
so the entity's state becomes `unknown` and the recorder stores a GAP. Read out
of home-assistant/core `dev` on 2026-09-24 and quoted at the constant.
`ABSENT_AS_UNKNOWN` is a one-key set and the suite asserts `circulation: None`
is STILL dropped.

THE UNIT IS READ OFF THE ENTITY. `mW`, `W`, `kW`, `MW`, `GW`, `TW` - HA's own
`UnitOfPower`, every factor an exact power of ten. A sensor with no unit, or a
unit outside that table, is REFUSED by name and the status page says which.
`read_inputs()`'s `abs(raw) < 50` kW-or-W guess is safe for a quarter-hour
demand forecast and is NOT safe here: 30 W of dusk is an ordinary reading and
that heuristic would publish it as 30 kW.

GENUINELY OPTIONAL, AND NOT A SECOND `price_now_entity`. validate.py does not
mention the key - it cannot conflict with anything, because nothing else reads
it. The MQTT row lives in a new `OPTIONAL_SENSORS` list whose `include` argument
DEFAULTS TO EMPTY, so every caller that has never heard of `pv_entity` -
test_mqtt.py's fixtures, tools/rehearse_roster.py, anything written next year -
announces exactly what it announced before. Unset: no state call at all, no
entity, no topic, no status row, no page row. Set and failing: a CAUTION
(`ok=False, warn=True`), never a `bad` row, so a telemetry channel can never put
a battery site into NOT READY.

IT MUST NOT BECOME A CONTROL INPUT, AND THAT IS GRADED TWICE. `test_pv.py`
part 6 drives 40 cycles of the real `cycle()` and asserts the commands are
bit-identical across unset / no reading / 0 W / 8 kW, with a COMPUTED census
(33 modules under app/) showing the material is mentioned in exactly three:
pv.py, main.py, mqtt.py. `tools/tel11_pv_trace.py` is the cross-tree half -
`safety56_behaviour_trace.py`'s pattern with a DIFFERENT control clause, because
this card's claim is that nothing differs rather than that only sentences do: it
REFUSES unless the two `app/` fingerprints differ and unless exactly one side
reacts to the option. Measured on 41 stimulus cells:

    control   release/1.0 unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      unset  846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    control   TEL-11      set    846a10a5b89e321086d535825925721e2f791012e8405948d4fd38d3f9d0be5f
    telemetry release/1.0 unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      unset  a443a6ceaffe072b44bcd5f2ad946c1ed6c9e01b69e278eca631f7f4d7892164
    telemetry TEL-11      set    4e6d1cb289a957223ad0205f732a6fec6110ce1f2032c98ad60694e67625274f

UNSET is byte-identical in BOTH documents, which is stronger than "the control
path is untouched": an install that does not set the option sees no change of
any kind, announcement and status rows included.

⚠️ AND THE CARD'S CENTRAL MUTATION WAS A SURVIVOR ON THE FIRST BATTERY.
`self.grid -= self.pv_w` in `read_inputs()` - +106 B, on disk, purged, genuinely
running - came back GREEN, because the fixture drove a 6 kW export over 12
cycles, which puts the loop AGAINST ITS RAIL: a command moving `slew_w` every
cycle produces the same ramp for -6000 W and for -14 000 W of apparent error.
MUTATION.md habit 23 with a saturated ACTUATOR in place of a coinciding value,
and it is in that file now as the habit's second instance. The fixture now
drives a 600 W import the loop SETTLES on, against a responsive meter, and asks
habit 23's own question as its own check: shift the METER by the same 8 kW and
confirm the commands really would have moved.

Evidence: 31/31 suites green in the CI image, checks.yml's exact command, purged
tree, `:ro`. Ten mutations, NO survivors, each on its own `cp -a` of the tree so
habit 18's revert hazard is closed by construction - table in
`DECISIONS/TEL-11-pv-production.md` §7 with byte deltas and sha256s.

⚠️ THIS IS A RUNTIME CHANGE BEHIND AN UNCHANGED VERSION, AND
`tools/predeploy_check.py` WILL REFUSE IT. `app/`, `config.yaml` and
`translations/` are all in its `RUNTIME` tuple and `config.yaml` still reads
0.10.1, so the gate reports a NO-OP deploy until a version is cut. That is PKG's
call and this card does not take it.

No CHANGELOG section: `test_version_gate.py` 11b refuses a newest `## ` heading
that is not config.yaml's `version:`, and opening one would mean taking that
same packaging decision. The operator account is in DOCS.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-24 15:35:07 +02:00
glenn schrooyenandClaude Opus 5 eb88646899 PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0
checks / unit (pull_request) Successful in 8m0s
The Supervisor decides an update exists by comparing config.yaml's version
string with the one the box reports. master and release/1.0 both said 0.10.0,
so SAFETY-57 - a deadlock that parked the reference battery for ~13 min on
2026-09-21 while the house exported 2.4 kW - had no way of reaching the box
that has it. A patch bump is the delivery mechanism, not bookkeeping.

- config.yaml: 0.10.0 -> 0.10.1. Nothing else in the option surface moves:
  no key added or removed, no default changed, no enum widened, no rule added
  to validate.py, so a blob that starts on 0.10.0 starts on 0.10.1.

- CHANGELOG.md: a new `## 0.10.1` section, holding SAFETY-57's entry moved out
  of `## 0.10.0`. The entry opened by saying it was misfiled and that whoever
  cut the next version owned moving it; this is that cut, so that paragraph is
  replaced by what an operator actually needs in order to decide - what the
  deadlock does (command parked at 0 W, batt reading gated to MISSING, escape
  condition unreachable from inside the state), how to recognise it (setpoint
  stuck at exactly 0 W with the battery register flat, a STALE line and no
  clearing line) and that a restart of the add-on clears it.

- PKG-16 proper: `## 0.10.0`'s preamble still claimed 0.10.0 "has never been
  built or pulled anywhere" and that the reference install was on 0.7.0. Both
  stopped being true on 2026-09-20 ~22:18 CEST, when 0.10.0 was installed as a
  repository add-on (slug 68285ac7_goodwe_controller) and began regulating a
  real battery. The section's own bump argument was explicitly conditional on
  that; the condition has fired, so the argument is retold as history and the
  section is closed. This text is what the Supervisor shows beside Update.

Also fixes, in this file only, the three non-blocking documentation defects
raised on PR #104 - issuecomments 1445, 1446 and 1447:

- 1446: the live episode is 790 s, not 710 s. Re-derived rather than rescaled:
  at >= 790 s the committed 16-day replay gives 16 of 93, not 17.
- 1447: the BMS keep-alive pulse was an inference stated as a measurement. No
  committed capture identifies one, and on this episode 0x0518 never moved at
  all. The measured claim replaces the firmware story.
- 1445: "neither consumer can reach a verdict inside one window" is universal
  as written and graded on a fixture that puts the obligation back on every
  release. It now carries the qualifier the reviewer asked for, and names the
  unbounded case and why the shipped one-inverter roster cannot reach it.

The same three defects also sit in app/freshness.py, test_freshness.py,
DOCS.md and the DECISIONS note. They are deliberately NOT touched here: this
PR is config.yaml and CHANGELOG.md only, and none of them is worth delaying a
live safety fix. SAFETY-56 and SAFETY-58 are likewise untouched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-22 15:22:03 +02:00
adminandClaude Opus 5 cb3f686555 PKG-14: cut 0.10.0, and say what an upgrade from 0.7.0 crosses
checks / unit (pull_request) Successful in 7m51s
`config.yaml` 0.9.0 -> 0.10.0, and the top `## Unreleased` block is closed
into `## 0.10.0` with a preamble that names the backward-incompatible
changes and who they reach.

MINOR, and NOT because eighteen tickets landed. A stored options blob the
previous version started on is REFUSED on this one:

  * TARIFF-07 retires three `price_provider` ids; a site set to one is
    refused BY NAME at startup. Measured on the reference blob, with a
    control on an accepted id so the refusals are about the ID.
  * TARIFF-18 moves `price_taxes_eur_kwh` 0.06 -> 0.11736. A site that
    STORED 0.06 is untouched, and - the non-obvious half - a taxes period
    table beside that stored 0.06 does NOT become a startup refusal on
    upgrade, because `SUPERSEDED_TAXES_DEFAULTS_EUR_KWH` reads it as
    untouched. Measured, with the counterfactual that the rung is not
    weakened (ORES's 0.1198 is still refused).
  * SAFETY-10 adds `shadow_mode`, shipped `auto`. An existing CONTROLLING
    install does not change by one watt and a FRESH one comes up observing.
    Measured cross-revision, 8f82dd4 -> e6da478, same stimulus through the
    shipped `Controller.cycle()`: byte-identical write streams, 13/13/25
    writes. Positive control: the same driver at `shadow_mode: on` gets 13
    writes to 5000 W on the older tree and one 0 W write on the newer.

And the one a reader of the newest section alone would miss: `ha addons
update` does not walk the versions, so a 0.7.0 install meets 0.8.0's and
0.9.0's rules at the same moment as 0.10.0's. Of those, SAFETY-39's rule 10
refuses 0.7.0's OWN shipped default `slew_w: 1000` against a 555.6 W
ceiling on a 5000 W rail. Measured red on this tree; the reference
install's `slew_w: 400` is measured green.

SCOPE, and it is drawn honestly rather than tidily. The top block's 18
entries all merged after the 0.9.0 bump `86bdf49`, so the block is closed
as-is and its `_this branch_` placeholders are resolved to merge shas.
⚠️ 0.10.0 SHIPS THREE MORE RUNTIME TICKETS THAT ARE NOT IN THAT TABLE -
SAFETY-43, TEST-21 and SAFETY-44 - and they are NAMED in the preamble
rather than moved, because re-filing this file's misplaced entries is
PKG-08. SAFETY-44 (`app/main.py`, `app/store.py`) is in the changelog
nowhere at all; that is said in both places. The second `## Unreleased`
block below `## 0.9.0` is ANNOTATED, not rewritten or emptied - UX-02 in it
shipped in 0.9.0, the other three in 0.10.0. No released section is
rewritten.

`test_version_gate.py` gains part 11: the bump and the closed section are
one act. PKG-09 refuses a deploy whose version did not move; nothing graded
the mirror failure, in which the version moves and the block is never
closed. Two sides from two files, a slicer with a synthetic positive
control run on every invocation, the retired ids read off `app/price.py` by
AST rather than transcribed, and the count of still-misfiled blocks frozen
so it can only shrink.

Mutations, all purged, tree bind-mounted :ro, backups at mktemp paths and
the revert fingerprinted:

  M1  `## 0.10.0` -> `## Unreleased`       +4 B    RED 2
  M2  version 0.10.0 -> 0.10.1             +0 B    RED 1   (ZERO-BYTE)
  M3  an id stripped from the NEWEST       +10 B   RED 1
      section only, left below
  M4  a 4th retired provider in price.py   +62 B   RED 1 here, 4 in
                                                   test_price.py
  M5  `## 0.9.0` heading lost              -3 B    RED 1
  M6  a 2nd `## Unreleased` left standing  +27 B   RED 1
  M7  the slicer never closes              -32 B   RED 3
  M8  SUPERSEDED_TAXES... emptied          -5 B    RED 2 on the evidence
                                                   instrument, plus
                                                   test_validate/test_price

⚠️ M5 WAS A SURVIVOR ON THE FIRST DRAFT. The slicer control was a sentinel
(`## 0.8.0`) that only a slicer running to EOF could reach, and deleting one
heading never gets there - ARCH-02's fifteenth instance, in a fresh costume.
11a now asserts the invariant instead: exactly one contents table per
section, which is what a lost heading breaks.

29/29 test files green. `tools/predeploy_check.py --deployed-version 0.7.0
--options <live blob>` CLEARED, exit 0, before and after.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-16 02:48:27 +02:00
Claude 8fa4febfef SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside
while it was happening, and each was paid for at the meter first: SAFETY-45's
28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong
quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain
310 Wh. There was no way to watch what the optimiser WOULD do without letting
it do it.

`shadow_mode` runs strategies, arbiter, clamps and guards, records the
decision with its reason, and commands nothing.

⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary
single writer. The inverter holds its last command forever - it has no meter
timeout - so "commands nothing" implemented as "stops writing" would leave
whatever was standing when shadow mode came on standing for as long as it was
left on, under a page saying nothing is being commanded. That is the failure
this repository keeps finding. Refreshing 0 W is also what
firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going
quiet would keep that board tripped for the whole run, which is an alarm being
used as a mode.

⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its
own. It is a substitution inside Controller._write_unit() - the single choke
point every write already reaches - in the same form as the three above it,
and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still
grade the number the decision path produced.

⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The
Supervisor composes options as {**config.yaml defaults, **stored user
options}, so a new key with a new default reaches EVERY EXISTING INSTALL on
the next update - including the one regulating a real battery. A boolean
default-on would have stopped it silently. There is no mechanism by which one
key can default differently for a new install and an existing one, so
"default-on for new" is a value the add-on RESOLVES: `auto` is shadow while
control is STOPPED and live once it is STARTED. A fresh install ships
`auto_start: false` and comes up observing; an install that is controlling is
started and does not change by one watt.

THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade
Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision
they would disagree with a meter that never saw it and LATCH A TRIP THAT
SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate
(SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation
(SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch,
because their evidence is measured power. The operator stop is the one
deliberate change: enforced at the wire rather than as a P_SAFETY claim, which
would otherwise make every recorded decision read "stopped".

⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what
stands on the wire, which makes the exit safe by construction - and therefore
the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow
run answers "what would it command now", not "what would it have done next".
The strategies are unaffected; all three defects above are visible from one.

Graded on the writes and on the rendered surface, never on the flag: 22
mutations, no survivors, including one that lets a write escape and one that
goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig,
same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %;
shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage
decision is identical in action, instant, signed power, reason and arbiter
winner.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-14 17:25:43 +02:00
glenn schrooyenandClaude Opus 5 995da777ce TARIFF-16: the injection leg stops being one number
checks / unit (pull_request) Successful in 7m42s
`price.py` modelled what a site is PAID for export as ONE scalar. The market
publishes a line, and the cards say so in their own words: Eneco Zon & Wind
Dynamisch `0,1 x BELPEX-H - 1,188` c EUR/kWh - "het injectietarief is dynamisch
en kan per uur wijzigen", identical on the January and the September 2026 cards;
ENGIE Dynamic `(B x eSpot_15) - A`; Aspiravi `0,07 x Belpex - 2`.
`price_export_formula` carries that line with its OWN coefficients.

⚠️ THIS IS NOT A WRONG-TRADE FIX, AND SAYING SO IS PART OF SHIPPING IT.
`arbitrage.py` does not read `export_price_eur_kwh` at all - its own comment
says so, citing §9.3's near-zero Belgian injection price as the reason the
economically sound trade on this market is charge-cheap-to-displace-expensive-
IMPORT. Both hours it compares are all-in CONSUMPTION prices. No trade this
add-on takes today is decided by an injection price and nothing here changes
one. What it changes is what an operator is told, and what a future
export-aware strategy rests on: OPT-06 and any export logic would otherwise
inherit a scalar that cannot represent the market, and the 6% VAT asymmetry
would be invisible in the arithmetic. test_price.py 17h parses every module
under app/ and goes red the day something calls an injection reader, so that
sentence is graded rather than attested.

FOUR PROPERTIES A SCALAR CANNOT HOLD. Its own factor (Eneco 0,102 consumption
against 0,100 injection; Aspiravi 0,07 against ~0,10 - not the consumption B
with a sign flip). A negative offset, which `price_markup_eur_kwh: float(0,1)`
cannot express at all. VAT-exemption - "injectietarieven zijn vrijgesteld van
btw" - against 6% on consumption, representable only because `vat_pct` is PER
SPEC. And a price that goes below zero with no floor, under 11,88 EUR/MWh of
BELPEX-H, which is the middle of a sunny day.

⚠️ A NEGATIVE INJECTION PRICE IS ACCEPTED, AND THAT NEEDED A DIFFERENT BAND
RATHER THAN A LOWER FLOOR. `implausible_all_in()` floors the consumption leg at
+0.02 EUR/kWh of energy; applied to injection that refuses the real market in
the hours it matters most. Measured rather than argued: 17c puts ONE spec
through BOTH bands and prints that the consumption band refuses -0.03008
EUR/kWh while the injection band accepts it. The floor was not decoration - it
is what catches a card read a hundred times too small, the one unit error the
card self-check cannot see because it cancels out of a comparison between the
two sides - so the bound moves OFF the price and ONTO the coefficients, where
it is index-free and sign-free: a pass-through band (Eneco's injection leg is
1.00x, Aspiravi's 0.70x; the band is 0.10-10x) and an offset magnitude bound
(0.20 EUR/kWh against published 0.01188 and 0.02). Two rungs that can both
answer a hundredfold error, so each is graded on its REASON, each gets a
stimulus the other cannot reach with the precondition asserted as its own
check, and they are mutated TOGETHER (TEST-16).

⚠️ THE CARD SELF-CHECK APPLIES WHERE THERE IS A CARD, AND WHERE THERE IS NOT
THAT IS STATED RATHER THAN WORKED AROUND. `price_formula` can require a `card`
block because a Belgian card prints the consumption formula, the reference
index AND the resulting price. Eneco's INJECTION formula is printed with no
price beside it. Requiring a block would make the published line inexpressible;
inventing the estimate would grade the coefficients against arithmetic done
with the same coefficients. So the block is OPTIONAL on this leg and unchanged
on the other, the self-check runs at the same tolerance wherever a printed
estimate exists, and validate.py says at startup - "its coefficients are
UNGRADED" - when it does not, naming the two bounds that ran instead. This is
TARIFF-15 demonstrating two tariffs end to end rather than three, one card
later. 17e also MEASURES the size of that gap: a factor of 0.070 where the
contract says 0.100 - 30% of every export payment - passes both bounds, because
0.70x is a pass-through somebody really publishes.

ONE PARSER, NOT TWO. `parse_export_formula()` is `parse_price_formula()` with
its OPTION NAME as an argument - TARIFF-17's move on `parse_static_profile()`,
exactly - and everything that differs between the legs is a string in one
`_LEGS` table. A second copy would be a second unit table, a second NaN rule, a
second unknown-key rule and a second `to_resolution()`, diverging first on the
23- and 25-hour days. test_price.py 17b pins it two ways: all 32 grammar names
are defined in exactly ONE module under app/, with the scope COMPUTED by
parsing every file rather than listed; and twelve refusal sentences for the new
option are DERIVED from the old option's own sentence rather than transcribed.
The four sentences that deliberately differ are named, with what differs, and
asserted to differ.

NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships "";
`export_price_eur_kwh()`'s body is byte-identical, pinned on the AST rather
than on the source text; `export_price_at()` falls through to it for every
index value. 17f compares seven option dicts x five index values against the
pre-TARIFF-16 expression with `==`.

`price_export_formula` joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is derived
from that set, and `code_leaks()` refuses a plugin that names it with nothing
else edited.

ALSO CORRECTED HERE: config.yaml's comment beside `export_price_eur_kwh` still
read "no shipped supplier publishes a dynamic injection curve". TARIFF-07
struck that claim from app/price.py and DOCS.md and did not reach config.yaml,
where it has been shipping since.

20 mutations, every one red on a named check, ledger in test_price.py below
section 17 - including a ZERO-byte one (the two legs transposed in the
VAT-asymmetry banner: no decision moves, only the sentence) and a ONE-byte one
(`card_required=True` on the injection leg). Three run over all 29 files and
red on test_price.py alone. 29/29 green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 18:41:06 +02:00
glenn schrooyenandClaude Opus 5 9c65ac2cf8 TARIFF-18: price_taxes_eur_kwh stops shipping at half the real figure
checks / unit (pull_request) Successful in 7m48s
`price_taxes_eur_kwh` shipped at 0.06 EUR/kWh with no recorded provenance -
no card, no date, no component list - and roughly HALF the true Flemish
all-in non-energy figure. It now ships at 0.11736, and the rows it is made
of are in the code rather than in this message:

  Fluvius distribution (Antwerpen)              5,35   c EUR/kWh
  Bijzondere accijns, "Alle verbruik"           4,876
  Bijdrage groene stroom en WKK Vlaanderen      1,51
  Energiebijdrage (0 EUR/MWh since 2026-08-01)  0
                                               ------
                                               11,736 c EUR/kWh = 0.11736

Eneco residential card for Flanders, September 2026, incl. 6 % VAT.
`app/price.py`'s FLEMISH_TAXES_COMPONENTS_EUR_KWH carries the rows and
test_price.py section 1b re-adds them - and also compares the total against
the card's own figures typed in the test file, so an edit that moved the
rows and the default together is still caught.

WHAT THIS IS NOT. It is not an arbitrage-correctness fix and it cannot be.
This scalar is a LEVEL component: an additive constant cancels exactly in
`max - min` and leaves the argmin where it was. TARIFF-17 shipped that proof
and it is unchanged - test_price.py 16b drives six flat scalars spanning and
exceeding the whole per-DSO range and gets the identical cheapest hour and
the identical spread to the last digit. DOCS and the CHANGELOG say so in
those words.

WHAT IT IS. A display and guard fix:

  * every number an operator reads, which at half the true value made the
    add-on look considerably better than it is; and
  * §17's negative-price guard in arbitrage.py - the one rung that tests an
    ABSOLUTE all-in price rather than a difference. It fires when
    `spot < -(markup + taxes)`, so its boundary moves -0.09 -> -0.14736
    EUR/kWh of spot. test_arbitrage.py section 2c drives both sides through
    the shipped decide() and pins the boundary from below as well.

The default is Antwerpen's real row, near the LOW end of the 0.117-0.131
per-DSO band, and that is deliberate: the error directions are not
symmetric. Too high carries a genuinely negative hour above zero and the
add-on exports into paid-for disposal - §17's own case. Too low only
declines a discharge that would have paid.

TARIFF-17's INTERACTION, WHICH HAD TO BE DECIDED. Nothing in that rung
hardcoded 0.06; it read PRICE_OPTION_DEFAULTS, so moving the default moves
what it refuses. The Supervisor sets `App.options = deepmerge(config.yaml
defaults, stored options)`, so a saved blob carries the key whether it was
typed or not - every stored 0.06 became "non-default" with nobody editing
anything, and a working Walloon or Brussels site with a taxes table would
have met SystemExit(78) on the upgrade over an inert number. price.py now
carries SUPERSEDED_TAXES_DEFAULTS_EUR_KWH = (0.06,) and validate.py reads a
superseded default as untouched too. The rung is NOT weakened: 0.1198 beside
a table is still refused by name, and the refusal now names both figures.

config.yaml and PRICE_OPTION_DEFAULTS moved together; CFG-03's tripwire
(test_price.py section 1, test_defaults_pin.py) stayed green by agreeing.
test_price.py section 0's fourth check was REWRITTEN rather than re-pointed:
it used to justify the file's own grading constants by observing that the
shipped pair was degenerate (0.06 is exactly twice 0.03). TARIFF-18 ends
that coincidence, so the sentence is no longer true and is not kept.

29/29 test files green. Mutation ledger on the PR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 16:24:56 +02:00
glenn schrooyenandClaude Opus 5 2fac0aaf06 TARIFF-17: a price component that varies by hour has somewhere to live
checks / unit (pull_request) Successful in 7m25s
`price.py` modelled the whole non-energy part of a Belgian bill as ONE flat
scalar. This adds `price_taxes_profile`, which carries the TAXES component as
a period table, and makes `assemble()` evaluate it at each point's own instant.

⚠️ THE FLAT SCALAR WAS NOT A WRONG NUMBER, AND THIS IS NOT A CORRECTION OF ONE.
The optimiser reads exactly two quantities off a series - the spread
`max - min` over the firm points, and which hour is cheapest - and an additive
constant identical in every hour cancels out of the first and leaves the second
where it was. It is provably inert. Measured, and printed by test_price.py 16b
on every run: with a flat taxes figure of 0.00, 0.0739, 0.1198, 0.1327 or 1.00
EUR/kWh the same 24-hour feed is cheapest at 13:00 in all five cases and its
spread is 0.1500 EUR/kWh in all five cases. What was missing is anywhere for an
HOUR-VARYING non-energy component to live. This is a missing capability, not a
bad constant.

Belgium has one. Fluvius distribution is a single rate - its tariff-card row
reads `Normaal | Uitsl. nacht`, where exclusive night is a separate physical
circuit and not a night register - so nothing changes for the reference site in
Flanders. The Walloon DSOs and Sibelga are on the same card with four columns,
`Enkelvoudig | Dag | Nacht | Uitsl. nacht`, and the gap is real money (c/kWh):
ORES 13,27 / 7,39; AIESH 15,17 / 8,21; Tecteo RESA 12,20 / 7,01; Sibelga
9,39 / 7,10; ORES IMPACT 2026 16,578 / 5,090.

⚠️ AND THE BANDS ARE ANTI-CORRELATED WITH WHAT THE BATTERY WANTS TO DO. The
cheap network hours are the cheap spot hours, so flattening them does not shift
the curve - it UNDERSTATES the spread and declines cycles that would have paid.
Same feed, same markup, the only difference being the taxes argument:

    flat 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000
                                       -> cheapest hour 13, spread 0.1500
    ORES dag 0.1327 / nacht 0.0739     -> cheapest hour 03, spread 0.1788

The regression check grades WHICH HOUR IS CHEAPEST, not the spread: an
implementation that reads the table once and adds one number to every point is
the LEVEL bucket wearing a period table - right magnitude, wrong shape - and a
spread assertion passes on it. Measured: hoisting the lookup out of
`assemble()`'s loop (+17 B) is red on six named checks in test_price.py and
GREEN in the other 28 files.

ONE GRAMMAR, NOT TWO. `static_tariff.py` already shipped the periods, the day
selectors, the tiling rule and the DST handling, so `parse_taxes_profile()` is
the same parser with the option name and the "what this number means" clause as
arguments. A second tiling rule would be a second set of 23- and 25-hour-day
bugs. test_static_tariff.py section 10 pins that two ways: by parsing every
module under `app/` and asserting the grammar is defined in exactly one of
them, and by deriving each of thirteen refusal sentences for the new option
from the old option's own sentence rather than transcribing them.

`Component.TAXES` semantics, `code_leaks()` and the double-counting guarantee
are untouched. The new key joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is
derived from that set, and a plugin that names it is refused at `register()`.
It reaches both plugins that take taxes - `custom_formula` ({ENERGY, MARKUP})
and `generic_dayahead` ({ENERGY}) - and not `manual_csv`, which is all-in: the
table is routed through `capabilities().adds`, exactly as the scalar is.

⚠️ A MALFORMED TABLE IS REFUSED AT STARTUP, NOT AT THE NEXT FETCH. It is read
on the ~30 s planning path, and a table that first fails at 03:00 is a site
that stops pricing at 03:00, which §11.4 turns into a quiet fallback
indistinguishable from a healthy fixed-tariff day. validate.py refuses three
things: a table that does not tile the day; a table set beside a NON-DEFAULT
`price_taxes_eur_kwh`, because the table wins and the scalar would then be a
number the operator typed that decides nothing; and a whole card typed in
CENTS, which is how these figures are printed. That last rung is not a
restatement of the parser's +-10 EUR/kWh bound - ORES's 13,27 trips the parser,
but Sibelga's entire card, 9,39 and 7,10, is under it and would otherwise have
started as a 9.39 EUR/kWh levy. Both rungs are graded by the REASON each gives,
and mutating them together (TEST-16) moves three rows.

NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships "", and the
scalar path is unchanged arithmetically rather than merely in intent:
test_price.py 16f reproduces the pre-TARIFF-17 expression and compares 12
capability/scalar combinations point for point with `==`.

13 mutations, every one red on a named check, ledger in test_price.py below
section 16k with byte deltas and the one equivalent mutant named. 29/29 green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 15:31:15 +02:00
Claude Opus 5 ac9854886b TARIFF-15: your own tariff card, as two coefficients the card itself grades
checks / unit (pull_request) Successful in 7m14s
A Belgian dynamic contract prices energy as `B x index + A`, and the two
coefficients exist on exactly one artefact: the customer's own tariff card.
There is no machine-readable source for them anywhere - CREG's consumer
tariff-card pages 404, CREG Scan is a JS wizard, the annual report has the
supplier list without per-product coefficients, VREG was unreachable, and
every coefficient found in research came off a supplier's own PDF, one
image-only. So nothing can be scraped and a per-supplier plugin would have no
source for its numbers, which is why TARIFF-07 withdrew three of them. The
customer is the only party who can see their own coefficients; they type them.

New provider `custom_formula`, one new option `price_formula` (a JSON string,
the `static_profile` precedent exactly), and a new module
`app/custom_formula.py`. The index path is `generic_dayahead`'s, not a second
one: the URL/override decision is now one shared `dayahead_feed_url()` both
plugins call, same feed, same Brussels-calendar range, same columnar parser,
same declared egress hosts.

It declares {ENERGY, MARKUP}, NOT ALL_IN. A card's Tariefformule line is the
energy component alone - Eneco tabulates network tariffs and levies
separately, ENGIE states the formula excludes network, distribution,
transport, levies and excise - so ALL_IN would lie for every operator who
typed what their card says and would drop the taxes from every hour
(0.2125 -> 0.1555 EUR/kWh, measured).

THE CARD IS THE GRADER, and that is why this is safe to ship. The framework
already mechanises that a PLUGIN cannot double-count. This introduces a risk
none of those guards can see because it is config, not code: the OPERATOR
double-counting, by folding network charges into `offset` while
price_taxes_eur_kwh carries them too. So validate.py recomputes the card's own
printed price from the operator's coefficients at startup and refuses to start
unless the two agree to within 0.01, naming the discrepancy. An inflated
offset cannot pass: 15.55 becomes 28.27. The same check catches VAT omitted,
VAT doubled, a transposed digit and a unit mismatch between the two sides.

And the limit, in the same sentence as the claim: it grades the coefficients
against the card, NOT the card against reality. A consistent-but-wrong pair
passes. A second refusal covers the one unit error the first cannot see - the
one applied to both sides at once - by bounding the card's own point to
0.02-1.00 EUR/kWh. Its FLOOR is applied to the energy figure rather than the
all-in one because the shipped 0.06 of taxes is three times that floor and
would carry a hundredfold error over it alone; found by writing the mutation,
not by review (M10, +0 B).

The market's own arithmetic, reproduced through the shipped code:

  Eneco (0.102 x 133.9905 + 1) x 1.06 = 15.5471   card prints 15,55
  ENGIE (0.1   x  61.96   + 0.9) x 1.06 = 7.5218  card prints 7,522

NO EXPRESSION EVALUATION OF ANY KIND. The string is settable over HTTP through
the add-on's own ingress page, so eval on it is RCE in a root container
holding SUPERVISOR_TOKEN and driving an inverter over RS485 - but the deciding
argument is that an expression is UNVERIFIABLE: two coefficients can be graded
against the card, an arbitrary expression cannot be graded against anything,
so it would make the invisible-wrong-coefficient problem strictly worse. An
unknown field is REFUSED rather than ignored, so `"expr"` is told it does not
exist. Future shapes become named fields, never a grammar. test_price.py 15f
walks the module's AST for eval/exec/compile/__import__/literal_eval and
exercises the scanner's red direction on every run.

Refused at startup: card absent or out by >0.01; `units` absent (no default);
factor == 0 (every spread 0, arbitrage silently never fires - the message
points at static_profile); factor < 0 (inverts the market); vat_pct outside
0-30 (0 stays legitimate); non-finite or non-numeric; unknown field, index or
resolution; the plausibility band. A card older than ~6 months WARNS and does
not refuse - ENGIE freezes coefficients for a contract's duration. Negative
output prices are not refused anywhere.

A startup preview logs the next 24 h as `index EUR/MWh -> all-in EUR/kWh` with
min/median/max and the day's spread, through a new default-silent
`PriceProvider.startup_preview()` hook - only the plugin knows what went in to
its own arithmetic. Emitted once per process, and a preview that raises cannot
cost the site its prices.

`custom_formula` joins the config.yaml enum through the DERIVED set
PROVIDERS | RETIRED_PROVIDERS | {"off"}, not a hardcoded list. Both
translations describe the option and the new id. DOCS.md replaces the
"planned" sentence with the shape, a worked example from a real card, a real
startup transcript and the limit of the check stated beside the claim.

22 mutations, one per check added, no survivors - MUTATION.md carries the
ledger. M13 (the preview's index column) was a -13 B survivor of the whole
suite on the first attempt because the check graded the HEADING and not the
row; it is graded on a rendered row now. All 29 suites green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 03:49:08 +02:00
adminandClaude Opus 5 f620f7cf80 TARIFF-07: three plugins that never fetched a price are withdrawn, and a site configured on one is told so
checks / unit (pull_request) Successful in 7m12s
engie_dynamic, totalenergies_dynamic and eneco_eddy are removed from PROVIDERS
and from every surface that listed them. They did not stop working - they never
worked. Re-verified by hand on 2026-09-13 before deleting anything: 404 with
Kong's "no Route matched with those values"; a TLS handshake that fails because
api.totalenergies.be is absent from the certificate's SAN list; 404 with an
empty body. All three are also structurally impossible - the coefficients are
per-contract and behind a customer login, there is no regulator index, and
"Eddy" is not an Eneco product at all.

⚠️ BACKWARD-INCOMPATIBLE. A config legal on the current version is refused on
the next. That is the point of the change: §11.4 turned every failed fetch into
a silent fall back, so a site on one of these ids has been running on
static_profile - or on nothing - since the day it was set, with nothing on its
status page ever differing from a working provider that never found a cheap
hour. validate.py now refuses a retired id with a message naming the id, the
endpoint, what that endpoint answers, which tariff has really been in force,
and what to set instead. No version number is picked here; that depends on a
fact about the live box.

⚠️ config.yaml's price_provider enum deliberately KEEPS all three ids. The
Supervisor validates the options file against that enum before the add-on
starts, so removing them would make an existing config schema-invalid and the
refusal above would never be reached on exactly the sites that need it.
PROVIDERS is two; the enum stays six; test_price.py asserts the schema offers
exactly PROVIDERS | RETIRED_PROVIDERS | {"off"}, derived rather than typed, and
register() refuses to re-register a retired id.

PriceProduct.REALTIME, _WIDE, Uncertainty.REALTIME_PRODUCT and WIDEN_FACTOR's
2.5 are KEPT with no shipped declarer - it is the AC2 seam, and a reviewer
finding a mechanism with zero callers would reasonably delete it. Recorded in
DECISIONS/TARIFF-07-withdrawing-three-plugins.md and pinned by a check.

False claims corrected: every "Belgian imbalance product" claim about
eneco_eddy (DOCS.md, price_forecast.py, price_history.py, static_tariff.py,
FCST-04, CHANGELOG - the two released entries annotated in place rather than
rewritten); the quarter-hourly examples now cite Belgian day-ahead, which
really does settle per quarter since the 15-minute MTU; and
export_price_eur_kwh's "no shipped supplier publishes a dynamic injection
curve", which is false - Eneco publishes 0,1 x BELPEX-H - 1,188 and ENGIE
(B x eSpot_15) - A, same two-coefficient shape with its own coefficients and
its own VAT treatment, so the scalar is a simplification and not the market.

DOCS.md's provider table is two rows and now says honestly what a Belgian
dynamic customer should do today, including that generic_dayahead cannot
express B x spot + A and that price_markup_eur_kwh: float(0,1) could not hold a
negative offset. The formula provider is referenced as planned, not built.

_points_from_json() went with the plugins it served: it read a shape no feed
anybody here has ever reached publishes. The one place it survives is a
negative stimulus, named row_shape_body().

Nine mutations driven, all red; table in the decision record. 29/29 suites
green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-13 02:46:15 +02:00
adminandClaude Opus 5 e6c45a61e7 TARIFF-10: configuring a price provider is what fetches prices
checks / unit (pull_request) Successful in 7m19s
amain() started the background tariff refresh only when arbitrage_enabled was
on, and that option ships false. run_tariff_refresh is the only caller of
resolve_tariff(), which is the only caller of price_history.carry() - so on a
shipped install with a price provider configured nothing was ever fetched: no
plan resolved, /data/price_history.json never created, the Price history status
row reading `empty` for the life of the install, and TARIFF-09's short-horizon
warning unable to fire because there was no fetch to warn about. Measured over
a 40 h two-instance soak on one feed: 0 requests and `present: false` across all
802 samples, against a resolved 132-point plan on the instance with arbitrage
armed.

git log -S puts the refresh task, its arbitrage.enabled() guard AND the DOCS.md
sentence saying a configured provider still fetches in the same commit - OPT-04,
bdd7f18; config.yaml has carried the claim since TARIFF-02, 852fc7c. The prose
and the code disagreed from the moment both existed and nothing compared them.
config.yaml and both translations additionally carried a claim that had rotted
the other way - "nothing consumes the price series yet", untrue since OPT-04
shipped the consumer. All four surfaces now say what the add-on does, and a
check pairs DOCS against the DRIVEN behaviour so they cannot drift again.

The gate is tariff_refresh_wanted() = provider_configured(opts) or
arbitrage.enabled(opts), and the `or` is a STRICT WIDENING: every configuration
that started the task before still starts it. The second term is not there for
symmetry. price_provider: off + a static_profile + arbitrage_enabled: true is a
configuration validate.py explicitly ACCEPTS and it trades - measured, at
cycle_cost_threshold_eur 0.05 on a 0.20/0.284 day/night profile,
ARBITRAGE_CHARGE -5000 W. Gating on the provider alone would leave that site's
tariff_plan at None forever and answer "no tariff plan has been resolved yet" on
every cycle, silently disarming a strategy the UI says is running.

Nothing acquires a periodic HTTPS call. With price_provider off, resolve_tariff()
answers out of the static profile without opening a socket (driven and counted:
0 requests), and the true shipped default - no provider, no trading - starts no
task at all. What decides whether a request leaves the machine is price_provider
and only that. The literal reading of the ticket's AC2 - drop the `or` - is one
token and is recorded in DECISIONS §3 with what it costs, for the owner.

AND NOTHING TRADES THAT DID NOT TRADE BEFORE. cycle()'s
`if arbitrage.enabled(self.o):` is untouched, and that is graded directly rather
than inferred from the gate having moved: Controller.cycle() is driven on a
resolved provider plan with the peak guard asserted clear, and arbitrage_enabled
is the only option that moves between the rows - false/false give +180 W
("loop -> 180 W") on both the cheap-now and dear-now plans, true/true give
-5000 W and +5000 W ("arbitrage -> ...").

TariffPlan.cheap_now() is deliberately NOT wired, decided rather than inherited
(DECISIONS §4). A provider-backed plan now exists on every configured site, so
Cheap window could read it - and Cheap window feeds the maintenance cycle's grid
top-up, the one place a price moves energy without trading being armed. On a
provider-only site static_status() returns False on every cycle, so adopting it
would take a paid grid top-up from never to sometimes. self.cheap stays on
static_status(); what adoption would take is listed rather than left implied.

THE CHECK THAT WOULD HAVE CAUGHT THIS is test_price.py section 13, and it grades
REACHABILITY FROM A CONFIGURATION rather than the shape of an `if` - the `if` was
exactly what somebody meant to write. amain()'s guards are EVALUATED against real
option dicts, whatever they are spelled as; the call graph under app/ is walked
to see whether the tasks those guards start arrive at resolve_tariff(), wherever
it has moved to; and then the fetch is DRIVEN with a counting transport, because
a graph is an argument and a counted request is an observation. What the
instrument cannot see is printed on every run, largest hole first.

Evidence: 29/29 green. 13 mutations in 14 runs - M10 re-run as M10b once it was
closed - each applied to a fresh cp -a of the clean worktree rather than
reverted (MUTATION.md habit 18), purged, :ro, -B. The
shipped defect - the gate back at arbitrage.enabled(opts), -4 B - is red on
seven named checks. Dropping the `or` (-27 B) is red on the strict-widening row;
removing cycle()'s trading gate (+8 B) is red on both AC3 rows. The instrument
is mutated too (habit 16): _reaches() always True and _task_sites() returning []
are both +0 B and both red.

Two findings are recorded rather than rounded off. provider_id() dropping
.strip() (-8 B) was a real SURVIVOR across four price suites - nothing fed a
padded provider id - and is closed in this commit by the padded-id pair; and the
first draft of the AC3 fixture fed five minutes of P1 telegrams, so whether the
peak guard was blind depended on where the wall clock sat inside the billing
quarter and the armed baseline failed to trade on some runs. It is 900 s now,
and the guard's clear state is a check rather than an assumption.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-12 20:58:48 +02:00
Claude Opus 5 17b7b447c4 TARIFF-09: ask the day-ahead feed for the horizon it was handed
checks / unit (pull_request) Successful in 7m10s
`generic_dayahead.fetch()` accepted `since` and `until` and requested the
bare `?bzn=BE`, which answers ONE Brussels day. Everything past today was
then filled from yesterday's profile by FCST-04, flagged provisional, and
§8.3 drops provisional hours from the trade set -- so the optimiser never
saw tomorrow as firm, at any hour of any day, and nothing reported it.

Measured on 4257e38 at 2026-09-10T09:00+02:00, 48 h horizon, live feed,
yesterday seeded through the shipped read path:

    60 firm points (15 whole hours) + 33 carried hours of 48 requested
    carried: 24 h on 2026-09-11, 9 h on 2026-09-12
    arbitrage(0.10): buy 11:45 and sell 19:45 -- BOTH on 2026-09-10
    firm local days = [2026-09-10]

The ceiling was structural: with a one-day window, at hour H a 48 h horizon
is at most 24-H firm and 24+H carried. At 23:00 that is 1 and 47, and the
remaining firm spread (0.0464 EUR/kWh) no longer clears the default 0.10
threshold, so arbitrage is refused outright. FCST-04's fill covers the
window until the ~13:00-14:00 CET auction; it was never meant to cover
every hour of every day.

The data exists and the endpoint serves it: verified 2026-09-10T07:45:49Z,
`?bzn=BE&start=2026-09-09&end=2026-09-10` returns 192 quarter-hours across
two local days. Committed unmodified beside TARIFF-08's captures, with the
URL, retrieval time and sha256 recorded and RE-DERIVED by the replay.

THE RANGE IS DERIVED ON THE BRUSSELS CALENDAR, not the UTC one. 22:30 UTC
in summer is already tomorrow in Belgium, so a UTC-derived start asks for
the day the controller has just left and drops the day it is standing in,
for the last one or two hours of every day. That is `_bdate()`'s lesson one
layer up with a worse consequence: `_bdate()` misfiles an hour, this never
fetches it. `until` is exclusive, so local midnight belongs to the day
before it; an inverted window collapses to one day rather than a backwards
range. Both ends are graded and both are driven red by mutation.

After, same code path and window, a feed serving both days: 39 firm hours
and 9 carried (was 15 and 33), firm across TWO Brussels days, and the
permitted cycle buys on one day and sells on the next.

`price_feed_url` IS THE EXACT URL AND THE PLUGIN APPENDS NOTHING. `start`/
`end` are this feed's spelling and the provider declares a second host
whose parameters are different, so merging would produce a request nobody
typed and the short horizon anyway. The cost is real, so it is not silent:
a WARNING on the shipped logger at fetch time names the consequence and the
start..end that would otherwise have been asked for. `dated_feed_url()`
refuses to append to a base that already carries a query string, so the
blind-append shape cannot come back by edit.
DECISIONS/TARIFF-09-the-range-and-the-override.md argues the alternative.

Before publication nothing regresses and it is graded, not assumed: at
09:46 CEST the two-day request came back byte-identical to the one-day
body, and that stays a `series` of what exists with FCST-04 filling the
rest. A `no_data` there would switch a working site's arbitrage off every
morning -- the mutation that adds that rule is red by name.

The plugin contract is still NOT enforced: three shipped plugins point at
endpoints nobody has verified, and a rule obliging them to pass a range
would be satisfied by an invented parameter name -- TARIFF-08's defect
moved from the response to the request. Which plugins consume the range is
pinned as a literal instead.

11 mutations, all red, no survivors; each applied to a fresh copy of the
tree rather than reverted, through tools/mutation_run.sh. One is +0 B (a
single price digit inside the committed capture) and the re-derived sha256
catches it. MUTATION.md habit 20 records why a fixture could never have
reached this: a captured body is the answer to a URL, and no property of a
body says which URL was asked for. All 29 suites green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-10 10:35:12 +02:00
Claude Opus 5 2271e147c6 SAFETY-43: delinquency measured against the ask, not against a flat 500 W
checks / unit (pull_request) Successful in 6m20s
`delivery.delinquent()` named a unit whose `short_by()` gap exceeded an
ABSOLUTE `min_w = Tuning.saturation_w = 500 W`. OPT-09's SoC-aware weights
shrink a low-headroom unit's share, and shrinking the share shrinks the gap, so
a unit standing at +125 W and delivering 0 W - 100 % delinquent - was never
named. Measured end to end on the real loop (test_packshare.py part 8b):

    load 1500 W, B wedged at 15 %, equal weights    named on 199/200 cycles
    load 1500 W, B wedged at 15 %, OPT-09 weights   named on   0/200 cycles

⚠️ The suppressed regime is the quiet one: at a load the healthy sibling covers,
the meter is satisfied, `unmet_w` is 0 and no action-log line fires, so this
alarm is the ONLY instrument that would have told the operator.

WHAT CHANGED, in one line:

    named if  short_by() > min_w  OR  short_by() > frac * share

⚠️ `min_w` WAS NOT LOWERED. It exists to stop normal saturation being reported
as delinquency, and lowering it trades a missed alarm for a false one on every
unit at once - SAFETY-41's four-attempt regime. This is a SECOND way to be
named, not a looser first one: all seven of test_delivery.py part 1's existing
fixtures answer identically under both rules, and the absolute arm's suppression
window is still exactly 1000 W / 6500 W, still asserted in part 8b.

THE FRACTION IS DERIVED, 0.85. admin/goodwe:sim/delivery_window.py gained a
`--fractions` axis and grades the constant over the SAME 2640 no-fault runs that
produced `delivery_hold_s`'s 35.0 s floor. Worst continuous legitimate episode,
worst of three families, twenty fractions:

    frac   0.05  0.10  0.15  0.20  0.25  0.30  0.35  0.40  0.45  0.50
    worst  90.0  90.0  70.0  70.0  60.0  55.0  55.0  60.0  45.0  45.0  s
    frac   0.55  0.60  0.65  0.70  0.75  0.80 *0.85  0.90  0.95  0.99
    worst  40.0  40.0  45.0  45.0  45.0  45.0  40.0  40.0  40.0  40.0  s
    absolute arm alone: 35.0 s (SAFETY-42 §3.3, reproduced in the same runs)

⚠️ NO CLIFF ANYWHERE: 0.45-0.99 is flat within one control cycle, and it is not
monotone - §3.3's own mechanism (c). ⚠️ "Zero false namings" is NOT achievable
at any fraction and the record says so; what is zero is false ALARMS - 90.0 s
worst against a 185 s hold, so nothing comes within 95 s of notifying anybody.
N=1 control 0.0 s at every fraction in all 2640 one-inverter runs; flapping
0.0 s in all 840.

DRIVEN. Part 8b pinned the SUPPRESSED behaviour and said "if it ever goes red
because the alarm fired, read the card that made it fire". It now grades BOTH
rules on one run - `share_frac=None` is SAFETY-42's rule exactly:

    OPT-09 weights, absolute arm alone   named on   0/200
    OPT-09 weights, the shipped rule     named on 200/200

POSITIVE CONTROL. Same fixture, same weights, same 125 W share, one legitimate
fact changed: a pack at its own 10 % cut-out is named on 0/200 (account() still
gates it), and a unit delivering HALF its share is named on 0/200.

N=1 BYTE-IDENTICAL, asserted: `plan()` handed a `weights` mapping that raises on
any read still answers identically at a roster of one, and the same mapping
raises at a roster of two; `delinquent()` answers {} on all 84 single-unit
(share, measured, rule) combinations including 0 of 125 W.

MUTATION, run on fresh :ro trees: M12 (drop the relative arm), M13 (frac -> 1.0)
and M14 (frac -> 0.05) are all red on named checks. The constant cannot move in
either direction unseen.

⚠️ CFG-07 gets ONE CONTROL CYCLE WORSE and is deliberately not fixed here: the
worst legitimate episode goes 35.0 -> 40.0 s, so the schema's `int(30,900)`
false-tripping band widens from [30,35] to [30,40]. CFG-07 should be re-derived
against 40.0 s.

No option value, no schema bound and no default changed. 27/27 suites green.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 03:14:16 +02:00
adminandClaude Opus 5 57775d4e06 TEST-21: delivery_hold_s's floor re-derived, and 30.0 s did not reproduce
No code and no option changes. What changes is a number this repository claimed
about a shipped safety constant.

`delivery_hold_s: 185` shipped resting on "30.0 s, the worst continuous
legitimate episode at the shipped threshold across all 2640 runs", plus a lag
sweep giving 45.0 s and 90.0 s - from a harness `DECISIONS/SAFETY-42` §1
deliberately did NOT commit, because it imports `plantsim` and `frame_check` out
of admin/goodwe. So the floor under a safety constant could not be re-run. That
is PROC-01's shape, with eleven instances in three days.

The harness is committed now, in admin/goodwe as `sim/delivery_window.py`, and
NOT here. `plantsim` and `frame_check` are that repo's; restating them in this
tree is CI-08's coupling, which has broken three times, and the alternative
fate - skipped for want of its imports - is a green that establishes nothing.
There the dependency runs one way: THIS repo's `control`, `arbiter` and the
shipped `delivery.delinquent()` are imported live out of whichever checkout is
under test. Its `--selftest` is now a step in that repo's `checks.yml`, so a
change here that moves `saturation_w`, `max_w`, `delivery_hold_s` or the shape
of `delinquent()` goes red there instead of leaving a stale number here.

    cd goodwe/sim && GOODWE_ADDON_REPO=/path/to/goodwe-addon \
        python3 -B delivery_window.py --selftest --campaign --blag

⚠️ THE HEADLINE DID NOT REPRODUCE: 35.0 s, not 30.0 s. Recorded as measured. The
harness was not adjusted until it agreed - the one correction made during the
rebuild was made AGAINST the doc's number (§1 records it) and made every figure
LARGER.

WHAT REPRODUCED - and it is the part the compatibility promise rests on:
  * the N=1 control arm is 0.0 s at EVERY threshold in EVERY run. §3.2's algebra
    measured, not argued.
  * the flapping family is 0.0 s everywhere in all 840 runs - the family that
    defeated SAFETY-30's site window still cannot touch this check.
  * 45.0 s at twice A's lag, to the cycle.

WHAT DID NOT:
  * the headline, by one control cycle (30.0 -> 35.0 s); the reversal family by
    two (20.0 -> 30.0 s).
  * the NON-MONOTONE curve. §3.3 finding 3 read 55.0 s at 250 W against 40.0 s
    at 100 W as a property of the reduction. This rebuild's curve is monotone.
    The mechanism is real and is still the reason not to read either table as a
    sensitivity curve, but it is an ARGUMENT now, not a measurement, and it is
    written down as weaker.
  * the low-threshold rows, badly (40.0 -> 120.0 s at 100 W). Nothing ships
    there, but that gap is the honest measure of how much of the original table
    was a property of axes nobody wrote down. §3.3 fixes every axis COUNT and
    RANGE and no individual value; the rebuild prints its choices above its own
    table so the caveat travels with the number.
  * the four-times-slower row moved the OTHER way: 75.0 s, not 90.0 s.

185 s IS NOT CHANGED. It is 5.29x the re-measured worst (the record claimed
6.2x), 2.47x the four-times-slower case, 6.2x the firmware's LINK_STALE_S veto
and 4.9x inside the billing quarter. All four bounds clear and none narrowly,
and the ordering of the argument is unchanged. Moving a shipped safety constant
because a margin went from 6.2x to 5.3x while every bound holds would re-open
SAFETY-41's four-attempt false-trip regime for nothing.

⚠️ ONE CONSEQUENCE AN OPERATOR CAN HIT. At 30.0 s the rig's floor coincided with
the firmware's veto and a reader could not tell which was binding. At 35.0 s the
rig's is strictly the binding one - and it is ABOVE the schema's own
`int(30,900)` minimum. `delivery_hold_s: 30` is therefore below a MEASURED
legitimate episode and would report on ordinary saturation. Both translations
now say so. Raising the schema floor is a change to a shipped option's contract
and is left to its own card rather than smuggled in here.

⚠️ THE B-LAG ROWS ARE RELABELLED THROUGHOUT. Inverter B does not physically
exist (~2026-09-12); `plantsim.INVERTER_B` is A COPIED, `measured=False`. Every
two-inverter figure in this record is two copies of A, and the lag sweep is a
SENSITIVITY STUDY ON A HYPOTHESIS ABOUT B, not a measurement of it. The old
wording - "MEASURED, not felt" - overstated exactly that, and "the RAMP does not
move it at all" was too strong: halving it is worth 0 s at A's lag and +5 s at
twice it.

Touched: DECISIONS/SAFETY-42 §1 and §3.3, app/delivery.py's provenance comment,
config.yaml's `delivery_hold_s` block, both translations, CHANGELOG Unreleased.
26/26 suites pass.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-07 21:47:08 +02:00
glenn schrooyenandClaude Opus 5 86bdf49332 PKG-12: bump 0.8.0 -> 0.9.0, so the five merges behind it can actually ship
checks / unit (pull_request) Successful in 6m14s
⚠️ MINOR FOR NEW FUNCTIONALITY, NOT FOR A BREAK, AND THAT DISTINCTION IS
CHECKED RATHER THAN ASSERTED. PKG-07 was minor because a config that started on
0.7.0 could be REFUSED on 0.8.0. Nothing of that kind is true here:

  - `options:` and `schema:` hold 71 top-level keys on both 06661c5 and HEAD.
    The one schema addition is a PER-ENTRY key, `capacity_kwh: float(0.1,200)?`,
    and the trailing `?` makes it OPTIONAL.
  - An unmodified 0.8.0-era config validates clean on 0.9.0. Measured through
    the shipped validator on both the flat single-inverter shape the reference
    install runs and an N=2 roster with no `capacity_kwh` on any entry: 0
    problems each.
  - OPT-09's two new refusals fire only on configs that USE the new key - an
    unparseable value, or the key stated on one entry and left empty on another.
    Neither can reach a config written before the key existed.

PKG-07's first draft justified its bump with an invented compatibility break and
review caught it. This one states what was measured, and the measurement says
existing installs upgrade untouched.

Contents since 0.8.0 (`06661c5`): UX-02 (`3d29993`), OPT-09 (`fdb3b69`),
PKG-09 (`fcaa724`).

⚠️ THE VERSION WENT UNBUMPED FOR THE THIRD TIME IN THREE DAYS - PKG-06 six
merges, PKG-07 six, this one five - and this time PKG-09's own tool caught it
during PKG-09's review rather than a person. The changelog carries OPT-09's
disclosed N=2 detection regression and points at the pre-deploy check.

⚠️ STILL NOT DONE, AND STILL NOT DOABLE FROM HERE: the live options have not
been checked against this version's validator. The gate reports exit 2 - NOT
CLEARED - rather than clearing, which is correct. Export the options from the
Supervisor and re-run before `ha apps update`.

Suite: 26 files, all pass.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-07 00:18:36 +02:00
glenn schrooyenandClaude Opus 5 f8e501393f OPT-09: the weights parameter nothing ever passed, and what it cannot do
`allocator.plan()` has taken a `weights` argument since ALLOC-01 and NOTHING
had ever passed one - main.py called `resolve()` without it and the arbiter
defaulted it to 1.0 per unit - so the site target was split 50/50 regardless
of what either pack could do. Two things now feed it, and they are different
kinds of thing:

  * a `pack` UNIT claim at P_SAFETY that CLOSES a unit's envelope at its own
    `bms_soc_floor` or at 100 % - a PERMISSION, obeyed absolutely, so an empty
    pack is not asked to discharge and its share goes to the sibling;
  * SoC-aware weights by ENERGY headroom in kWh - a PREFERENCE, which
    `_fill()`'s last-resort pass will override the moment the sibling saturates.

Measured (test_packshare.py part 8): at a load one pack cannot cover, the
weighted arm and the shipped arm command the IDENTICAL watts into an empty pack
and deliver the IDENTICAL watts. Only the envelope stops the ask, and what it
buys is not delivery - it is a reported `unmet_w` where the record used to read
impeccable. Weights are a comfort choice for STABILITY and NOT for DELIVERY.

Also: an optional per-entry `capacity_kwh` (schema change, all-or-nothing across
the roster, rule 9 refuses a partial one); per-pack arbitrage sizing, with the
sell side's no-op stated rather than hidden; and a 0 W trade refused by name,
because a 0 W arbitrage claim is a park order that outranks the loop.

SAFETY-42 and this card meet at one hazard from opposite sides - OPT-09 stops
the site ASKING a pack whose SoC says it cannot deliver, SAFETY-42 alarms when a
pack that said it could does not - and its end-to-end fixture moved as a result.
Its finding is unchanged and is now stated on the two quantities its rejected
discriminator actually reads.

Not filed at all at a roster of one: at N=1 every source routes to the site, so
the interval would bound the SITE TARGET, and SAFETY-25's decided Option A
stands untouched on the live install.

⚠️ INVERTER B DOES NOT EXIST. Its 4600 W / 20.48 kWh / 10 % are FROM DATASHEET
AND SERIAL, and `sim/plantsim.py`'s INVERTER_B is inverter A copied
(`measured=False`), so every two-inverter figure here is arithmetic or two
copies of A. No hardware was touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 22:55:20 +02:00
glenn schrooyenandClaude Opus 5 06661c5e17 PKG-07: bump 0.7.0 -> 0.8.0, because 0.7.0's own default is now a refused config
checks / unit (pull_request) Successful in 6m6s
Six merges landed behind an unbumped 0.7.0 - CI-06, SAFETY-38, SAFETY-39,
SAFETY-37, SAFETY-13, SAFETY-42. PKG-06 recorded this exact failure YESTERDAY
(bbc903b, 2026-09-05 19:23): the Supervisor keys the built image by `version:`,
so `ha apps update` against an unchanged version is a silent no-op and the box
keeps running the old tree. Catching it by hand a second time is the argument
for the automated check PKG-06's follow-up still owes.

MINOR rather than patch, and the reason is sharper than a semantic change:
SAFETY-39's validator rule 10 refuses an explicit `slew_w` above
SLEW_RAIL_FRAC x the site rail - 555.6 W on a 5000 W rail - and 0.7.0's own
SHIPPED DEFAULT was `slew_w: 1000` under schema `int(50,5000)`. An install that
never touched the key is refused on 0.8.0. Refusal is SystemExit(78); the
add-on does not start.

⚠️ AN EARLIER DRAFT OF THIS COMMIT JUSTIFIED THE BUMP BY CLAIMING `slew_w: 0`
USED TO MEAN "no limit" AND NOW MEANS "follow the rail". THAT WAS FALSE AND IS
REMOVED. The schema was `int(50,5000)` from the repo's first commit through
0.7.0, so 0 was never a legal value and never meant anything; and the old
`control.py` had no zero case - at slew_w=0 it pinned the command to its
previous value, freezing it, which is the opposite of "no limit". The widening
to `int(0,5000)` is a NEW capability, not a changed meaning. The bump is right;
the story told for it was invented - PROC-01's defect appearing in the very
commit that complains about process.

⚠️ AND THEN A SECOND ONE, IN THE SAME COMMIT: the text said PKG-06 was "three
days ago" when the two commits are about a day apart (2026-09-05 19:23 ->
2026-09-06 20:03). Caught in round 2 and corrected. Two invented facts in one
documentation-only change is the measurement PROC-01 wants, not an anecdote:
both were plausible, neither was load-bearing, and both would have shipped.

⚠️ THE PRE-DEPLOY CHECK THIS IMPLIES IS NOT DONE AND CANNOT BE DONE FROM HERE.
Whether the LIVE options survive rule 10 depends on the live `slew_w`, and the
options blob is only reachable through the Supervisor API, which needs a token
this session does not have; the HA REST API does not expose it and no entity
carries it. On record `slew_w` was set to 400 during the SAFETY-39 interim fix,
and 400 is below 555.6 - but that is a written record, not a reading, and the
value has been hand-edited since. Read the options and check them BEFORE
`ha apps update`. Exit 78 also takes the ingress panel down, because the add-on
serving it is not running.

The contents table now carries each merge subject's WHOLE claim. Two rows had
been trimmed to their flattering halves - SAFETY-39's "`gain` is the constant
that is still wrong" and SAFETY-42's "the discriminator the card asked for does
not exist" - and both are restored.

Separately, `## Unreleased` was a lie twice over: two headings by that name, one
spanning ~3000 lines across three releases, one from the 0.4.x era, and every
word under both is shipped and running. Retitled, not re-sorted; the split is
PKG-08.

Reviewed twice. Round 1 REJECTED for an empty PR - built in a clone a concurrent
agent was using, and "pushed" reported from the command's echo rather than from
the remote ref - and for the fabricated slew_w story. Round 2 APPROVED with the
date as a non-blocking finding, fixed here.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 20:16:39 +02:00
Claude 090a8ecc35 SAFETY-42 round 2: pin the two thresholds at a config that is not the shipped one
checks / unit (pull_request) Successful in 6m7s
THE BLOCKER. At the `delinquent()` call site, `self.tuning.saturation_w` ->
`250.0` (-19 B) was a survivor of all 23 suites. It is not an equivalent
mutant: two copies of inverter A, B wedged, `saturation_w: 1800` (inside its
own schema int(100,2000)) and a load of 1600 W put B's shortfall strictly
between the literal and the configured value - head names nobody, the mutant
names B. At the shipped 500 both name it, which is exactly why every fixture
in part 4 was blind: their gaps are all above both thresholds.

It matters beyond a mutation score. `delivery.py`'s MIN_W_IS_SATURATION_W note
and the `delivery_hold_s` block in config.yaml both promise an operator, in
shipped prose, that there is no fourth copy of a threshold to keep in step and
no way for the two to drift - raise `saturation_w` and this check moves with
you. A literal at the call site removes exactly that promise, silently, and
the promise is why the design was chosen over a `delivery_w` key.

ASKING THE SAME QUESTION OF EVERY OTHER NUMBER THIS CHECK READS FOUND A SECOND
SURVIVOR OF ALL 23 SUITES: `bms_floor=inv.bms_soc_floor` -> `10.0` (-13 B),
invisible because config.yaml's own example states 10 % and every fixture in
this file used it. Two arms bracket it: a pack at 15 % against its own 25 %
cut-out is cold and must stay unnamed (the literal names an empty pack), and a
pack at 8 % against its own 5 % cut-out is wedged and must be named (the
literal explains the fault away). One arm on each side leaves no constant at
all.

`delivery_hold_s` and `is_live()`'s window were ALREADY pinned - the fixtures
had to move them to run - and `LINK_STALE_S` has no option behind it, so
"pinned across a changed config" is not available for it and is not claimed.
DECISIONS section 9 enumerates all of it with the deltas and which check kills
which.

Verified in the CI image, tree mounted :ro, `python3 -B`, `__pycache__` purged
and counted before every run (TEST-15):
  R5 saturation_w -> 250.0                    -19 B  killed by part 4b(a)
  R6 bms_soc_floor -> 10.0                    -13 B  killed by part 4b(b), both arms
  R7 arm(self.delivery_cfg) -> DeliveryConfig()  -1 B  killed (already)
  R8 is_live(now) -> is_live(now, 3600.0)      +8 B  killed (already)
  R9 pack cut-out -> conjoined site floor    +105 B  killed twice
  head: 23/23 test files PASS, no bytecode written during the run.

No shipped behaviour changes: the only edits to app/ are comments.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 19:25:45 +02:00
glenn schrooyenandClaude Opus 5 706e625d99 SAFETY-42: a unit that stops delivering, and the discriminator the card asked for does not exist
A unit standing at a non-zero share and producing nothing is seen by NOTHING.
SAFETY-30's per-unit sign gate needs OPPOSITION on both sides of 250 W and a
unit at 0 W is not opposing, it is ABSENT. The site sum still agrees with the
meter in direction. Circulating power is exactly zero when one unit does
nothing. The only trace left is `reason == "saturated-freeze"`, which
clamp.py:93-96 documents as the alarm an operator learns to ignore. It is
HW-01's shape, which ran 6 h 25 m with all three layers spectators.

⚠️ THE CARD'S OWN DISCRIMINATOR WAS BUILT FIRST AND FALSIFIED, AND THAT IS THE
MAIN CONTENT. SAFETY-42 asks for "saturation persisting past N while
|grid error| > X, both derived". Run on the two-master rig it fails in BOTH
directions, and no (N, X) fixes either:

  FALSE POSITIVE  `plantsim.Plant.limit()` returns 0 W for a discharge command
      into a pack at its own floor, and a wedged unit produces 0 W too. Load
      2000 W, equal weights, 2000 W per-unit cap, 120 cycles: THE TWO ARMS ARE
      IDENTICAL ON ALL 120 in grid, site target, every share and every measured
      watt. Both saturated-freeze on 116 of them, both hold |grid error| over
      300 W on all 120 and settle at 1200 W, both read circulating 0.0 W. The
      predicate's inputs do not differ, so no threshold on them can differ. And
      "a cold pack at its floor must not alarm" is the card's own AC 2.

  FALSE NEGATIVE  the standing grid error is what a HEALTHY SIBLING ERASES.
      Load 800 W, same config, B wedged: over the last 30 of 200 cycles the loop
      is frozen on 30 of 30 while the worst |grid error| is 30 W, with B standing
      at +770 W and delivering 0 W. Any X above 30 W is silent for the whole run
      on the exact fault the card describes.

WHAT REPLACES IT. Per unit, for a discharge share, `share - measured`; readable
because of a reduction that only exists at N>=2:

    a unit is named while it is short by more than `saturation_w` with NO
    ACCOUNT for it, and the units in that state are a PROPER SUBSET of the units
    asked to discharge.

THE ACCOUNT keeps the cold pack out and is the only thing that can: the two
cases are identical in the power domain, so the discriminator has to be a
non-power fact, and there is exactly one - the pack's own SoC against its own
`bms_soc_floor`, asked through `peakguard.discharge_permitted()` rather than
transcribed. ⚠️ `bms_soc_floor` ALONE, not `pack_floor_pct()`'s conjunction with
`peak_soc_floor`: that floor bounds a money-saving discharge only and using it
would explain away a wedged unit anywhere between the two.

THE PROPER SUBSET keeps a whole-site cause out - a derate this add-on cannot see
hits every unit; one box that stopped listening does not - and it is what makes
this INERT AT N=1, by algebra rather than by a roster guard.

IT REPORTS. IT DOES NOT ACT, and the strongest argument is for acting. Dropping
the wedged unit from `live` genuinely recovers a site the shipped path does not:
at load 1500 W, kept in the split the site settles at 800 W with a 700 W error
and NEVER comes inside 100 W in 150 cycles (the freeze pins the target, so the
sibling's SHARE never grows); dropped, it delivers 1500 W from cycle 14. What
refuses it is that the only re-allocation this add-on can express is
all-or-nothing: a unit derated to 50 % is short by more than saturation_w with
nothing to explain it, so this detector names it too, and at load 3000 W
dropping it leaves the site delivering 2000 W against 2400 W kept - 400 W WORSE.
A partial re-allocation is what would make acting safe and the allocator cannot
express it. That is a card.

control.py is NOT MODIFIED. The freeze shapes the loop; this reports on it.

NUMBERS, MEASURED. The watts side is `Tuning.saturation_w`, read at runtime, so
there is no fourth CFG-03 copy and it cannot drift from the number the control
law itself calls "not following". `delivery_hold_s: 185` comes off 2640
closed-loop two-inverter runs in which nothing is faulty (6 gains x 5 slews over
the whole schema range, across load reversals, a flapping load and ASYMMETRIC
SPLITS - a family SAFETY-30's campaign did not have and the one that dominates
here) plus 1890 runs at a roster of ONE as the control:

    threshold   reversals   flapping   weighted   N=1 control
     * 500 W      20.0 s      0.0 s      30.0 s      0.0 s

The N=1 column is 0.0 s at EVERY threshold in all 1890 runs, and the flapping
column - the family that defeated SAFETY-30's site window - is zero too, because
a common stimulus makes both units short at once and the subset stops being
proper. ⚠️ The curve is NOT monotone (55.0 s at 250 W against 40.0 s at 100 W):
lowering the threshold can turn a proper subset into the whole roster and BREAK
the run.

⚠️ THE MARGIN IS MEASURED, NOT FELT, BECAUSE INVERTER B DOES NOT PHYSICALLY
EXIST. `plantsim.INVERTER_B` is A COPIED, `measured=False`, so every two-inverter
figure above is two copies of A. Sweeping a different second unit: the worst
legitimate episode is insensitive to B's RAMP (30.0 s at half A's) and scales
with its LAG - 45.0 s at twice A's measured 10 s, 90.0 s at four times it.
185 s is 6.2x the measured worst, 2.06x the four-times-slower case, 6.2x
LINK_STALE_S and 4.9x inside the 900 s quarter. Deliberately not 180, which is
SAFETY-02's site hold.

SAFETY-34. `unit/<name>/delivery_tripped` in the store, one notification id per
unit, re-raised on the first cycle of every process, cleared by the Start press.
No flat mirror: a rollback lands on a version that drives one actuator, where
this check is inert.

⚠️ SCHEMA CHANGE - `delivery_hold_s` joins options: and schema:, so this needs a
version bump before it ships. Additive and defaulted, so an existing options blob
stays valid.

STATED GAPS: charge shares are not graded (no configured charge ceiling exists,
so a constant-voltage taper cannot be explained and arming it would fire on every
maintenance charge); every unit wedged at once is not caught (the subset is not
proper and no instrument here separates that from a plant that cannot).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 19:25:45 +02:00
adminandClaude Opus 5 5d7e275df4 SAFETY-39: slew_w is a ratio to the rail, and gain is what is still wrong
checks / unit (pull_request) Successful in 5m16s
`slew_w: 1000` was derived on 2026-08-22 against a clamp of 1500 W, where
"capping how far the loop can jump ahead of the inverter" was true because the
rail itself bounded the excursion. The live install went to max_w 5000 and the
constant did not move, so the loop crosses its whole output range in 10 s
against a plant NOTES.md §5.10 measured at ~18 s. Measured on the owner's system
2026-09-05 11:43-11:46: a 3.4 kW export drove the setpoint 380 -> 5000 W in five
2 s ticks, the battery to -5154 W past a 5000 VA rating, and the grid from
3.4 kW of EXPORT to 2.8 kW of IMPORT. Nothing was broken; the rail moved.

REPRODUCED FIRST, and one half of it is not reproducible at all. On
plantsim.Plant and on an independent in-repo model: the setpoint stepping a full
1000 W per tick to the rail (48 of 51 export steps), and the meter crossing from
export into import. The -5154 W figure is NOT reproducible in either model,
because both clamp the plant at its rating - so the card's AC "battery no longer
exceeds max_w in simulation" is unfalsifiable and was rewritten rather than met.

THE DELIVERABLE IS THE RELATIONSHIP.
  SLEW_RAIL_FRAC = LOOP_TICK_S / PLANT_SETTLE_S = 2 s / 18 s = 1/9
  slew_w = 0 now means FOLLOW THE RAIL - SLEW_RAIL_FRAC * max_w - exactly as
  integrator_max_w = 0 already means follow max_w. It is the shipped default:
  222 W at max_w 2000, 556 W at 5000, 1067 W at a ~9600 W two-inverter site.
  validate.py rule 10 refuses an explicit value faster than that, graded against
  sum(unit_caps(opts)) - the roster sum, i.e. Controller.site_max_w - so a
  second inverter moves the bound with no operator action.

VERIFIED BY BREAKING IT: restoring slew_w 1000 at max_w 5000 is refused, and the
refusal names the rail, the crossing time, the measurement and what to do.
Equality, one watt of slack, the live interim 400 and slew_w 0 at every rating
all still start.

GAIN IS THE CONSTANT THAT IS STILL WRONG, and it is NOT changed here. Over 51
export steps the over-absorption is FLAT in slew (958 W at 1000, 1081 W at 250)
and monotone in gain (987 W at 0.6, 876 at 0.3, 435 at 0.2): slew_w bounds the
OUTPUT, while the integrator moves gain*error per cycle and reaches a 5000 W
rail in under three ticks whatever the slew is. Two control-law constants moving
in one release on a running house makes the next measurement uninterpretable.

⚠️ N=2: the site rail becomes sum(max_w) ~ 9600 W (inverter B FROM DATASHEET AND
SERIAL, not measured, and sim/plantsim.py's INVERTER_B is A copied), and the
enforced ratio produces 1067 W there automatically. But a growing rail LOOSENS
this bound, and the >= 900 W symptom goes stale at N=2 the same way the constant
did - both stated in the record rather than left to be discovered.

Nothing reached the inverter. The live install still runs the interim slew_w 400
applied by hand on 2026-09-05, which rule 10 accepts unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 01:10:15 +02:00
glenn schrooyenandClaude Opus 5 d8e02ad3f8 PKG-06: bump 0.6.0 -> 0.7.0, because the schema changed and nobody bumped
checks / unit (pull_request) Successful in 5m2s
Six merges landed since 0.6.0 was deployed and the version never moved.
Disk and box both read 0.6.0, so `ha apps update` would have been a
NO-OP: Supervisor keys the built image by `version:`, and the update path
installs `version_latest`, which cannot differ from `version` without a
bump. Found while pre-checking the deploy, not after it silently did
nothing.

⚠️ MINOR RATHER THAN PATCH, BECAUSE THE SCHEMA CHANGED. SAFETY-32 added
`bms_soc_floor: int(0,50)` as a REQUIRED per-entry key on the `inverters`
roster - no trailing `?` - so a config declaring a roster and omitting it
on any entry is refused at startup. Verified against the deployed
2d025ee: the per-entry schema went from 6 keys to 7. Top-level options
and schema are unchanged at 63 each.

An install running `inverters: []` is unaffected, which is every
single-inverter install including the reference one: the flat
`bms_soc_floor` still describes the one pack. But CFG-04 recorded the
rule this follows - "a schema change without a bump is a schema nobody
reads" - and this is exactly that shape.

The CHANGELOG gains a 0.7.0 section listing the six merges by SHA. It
also records, rather than papers over, that 0.6.0 was never sectioned:
its content sits below the new heading because the earlier bump shipped
without cutting a section. Splitting it retroactively would mean guessing
a boundary; the deployed 0.6.0 is 2d025ee and the table says what is new
since it.

Full suite: 21 passed, 0 failed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-05 18:38:41 +02:00
Claude Opus 5 fef6ef20a4 UX-01: translate the add-on config, and order it by task
checks / unit (pull_request) Successful in 5m1s
The add-on had NO translations/ directory, so Home Assistant fell back to
rendering the raw option KEYS. An operator opening Configuration read
`unit_sign_disagree_w`, `saturation_cycles`, `integrator_max_w` - seventy of
them, in file order, with no description and no way to tell a constant derived
from 1890 closed-loop test runs from their own inverter's rating.

⚠️ PRESENTATION ONLY. Not one default, not one schema range and not one line of
behaviour moved. The 175 non-comment lines of config.yaml are byte-identical to
release/1.0's, reordered; the only comment lines that changed are the group
banners and five sentences whose "above"/"below" the reorder made false.

* translations/en.yaml and translations/nl.yaml: a name and a description for
  all 70 options and all 7 per-entry keys of the `inverters:` repeatable
  section. The Dutch is written for a Flemish homeowner - afname/injectie,
  kwartierpiek, capaciteitstarief - not transliterated from the English.
* ⭐ Every derived constant says WHERE IT CAME FROM and whether to touch it.
  `unit_sign_disagree_s` cites its 1890 closed-loop runs (SAFETY-30);
  `circulation_w` its 924 runs and the measured 400 W knee (SAFETY-31);
  `meter_freeze_s` its 2399 s capture (SAFETY-18); `bms_soc_floor` register
  0x0560. The two numbers that are the operator's - max_w and peak_cap_w - say
  "THIS IS YOUR NUMBER". `cycle_cost_threshold_eur`, which is neither, says it
  is an open product question (OPT-08).
* config.yaml reordered into task order in BOTH halves, comments carried with
  their keys: hardware -> meter -> ratings and limits -> tariff -> maintenance
  -> safety -> advanced.
  ⚠️ test_inverter.py:1788's trap is PRESERVED: the nested per-entry `max_w:`
  still precedes the flat one under `schema:`, and `inverters: []` still ships
  in the `options:` half. Moving the nested block below the flat one is a 1-byte
  edit; it was run and goes red in test_inverter.py and test_translations.py.
* tools/supervisor_shape_probe.py section F MEASURES the result against
  ghcr.io/home-assistant/amd64-hassio-supervisor:2026.08.0 - Supervisor's own
  _read_app_translations(), its own UiOptions, and the frontend's label
  resolution transcribed from the shipped bundle - and prints every rendered row
  in both languages. `all cases passed`, exit 0.
* ⚠️ ONE MEASURED NEGATIVE RESULT, NOT GLOSSED: the per-entry keys inside the
  `inverters:` section still render RAW on frontend 20250925.1, because a
  list-of-objects goes to ha-selector-object and the converter sets no `label`
  and no `translation_key`. The `fields:` translations are shipped and validated
  - that is Supervisor's own shape for this - but this card does not claim they
  reach the screen. The `inverters` label and description do.
* test_translations.py: a translation naming a non-existent option, or an option
  with no translation, fails CI - both directions, both languages, top level and
  per entry. Mutation-tested BOTH WAYS: eleven in-process mutations each
  required to NAME the key they broke, plus a negative control; six more run on
  disk through the purge-and-re-read protocol. Two of the eleven are the ones
  that cost the WHOLE FILE rather than one label - an unrecognised top-level
  block, and a `network:` value that is not a string. Supervisor drops a file
  that fails SCHEMA_APP_TRANSLATIONS with only a log warning, so those silently
  return the entire tab to raw keys; neither is reachable through the
  `configuration:` coverage, which is why they were hunted for and closed.
* tools/translations_lint.py is the hand parser CI needs (no PyYAML in the
  add-on image) and the probe grades it, key by key and string by string,
  against Supervisor's own loader. It is strict and RAISES rather than skipping;
  nine malformed shapes prove it.

Full 20-file suite green (19 existing + test_translations.py).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-05 12:02:56 +02:00
adminandClaude Opus 5 f9e7fbf86d SAFETY-32: bms_soc_floor per pack, rule 8 per unit
`bms_soc_floor` describes A BATTERY, not a site. At two packs of different
models the cut-outs differ, and one number for both graded the shallower pack
against the deeper one's BMS - so a site with cut-outs of 10 % and 30 % under
`peak_soc_floor: 20` STARTED, and the guard would command a forced discharge
that pack B's BMS, not the operator's floor, is the thing that stops. That is
rule 8's own failure mode, reached through rule 8.

Scoped to the card's third bullet, per its PM PROOFREAD: the aggregate
anti-windup (DEV-02) and per-instance `achievable_w` (CFG-04) were verified as
already shipped and are untouched.

* config.yaml: `bms_soc_floor: int(0,50)` REQUIRED per `inverters:` entry.
  Nothing is inherited; the flat key stays the single-inverter shape's own
  cut-out. A per-entry DEFAULT was declined - a default is one number for every
  pack, which is this card's defect - and the decision is recorded.
* inverter.py: `Inverter.bms_soc_floor`; an entry that states none gets None,
  not a borrowed number and not 0.0 (the most permissive value the key has).
* peakguard.py: `Pack`, `pack_floor_pct()`, `pack_permissions()`,
  `binding_soc_floor()`. `discharge_permitted()` is unchanged and is still the
  one place the question is answered.
* validate.py: `unit_bms_floors_indexed()` carries the ROSTER index; rule 8
  grades EVERY unit and NAMES the one it refuses. Graded with the offender
  SECOND and with the same two numbers in the other order.
* main.py: `Controller.packs`; `decide(soc_floor=...)` is the per-pack
  reduction of the same option; the floor-limited notification names the pack
  that stopped the site. `pack_floor_soc` - the emptiest pack, and its
  None-on-missing behaviour - is untouched.
* tools/supervisor_shape_probe.py: RE-RUN and repaired. The required key broke
  §C and left §D printing PASS on a refusal about a different key. §D is now an
  isolated counterfactual over an accepted merged baseline, one key varied,
  asserting the key name. `all cases passed` on 2026.08.0.

Stated rather than hidden: under any config rule 8 accepts the per-pack FLOOR
reduces to `peak_soc_floor` for every pack. The reduction is written for
`unit_caps_indexed()`'s reason and graded on both sides - 1775 rule-8-valid
pairs answer the option, the pair rule 8 refuses answers the cut-out.
`peak_soc_floor` is still one number for the site, so the "deeper pack
needlessly withheld" half is filed as an open question, not closed.

Full 19-file suite green. Twelve source mutations through
tools/mutation_run.sh: eleven red, one argued survivor. The battery also found
`_flat_bms_floor()` defaulting in two places, each covering for the other.

No measurement of inverter B appears anywhere: it does not exist yet. Every
second-pack figure is simulated and labelled.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-05 03:01:57 +02:00
glenn schrooyenandClaude Opus 5 a9993aeda2 SPIKE-04a: inverter B is 4600 W FROM ITS DATASHEET, and the copies are pinned
checks / unit (pull_request) Successful in 4m51s
The desk half of SPIKE-04. No control behaviour changes; this is documentation
and the check that stops it drifting again.

Three places stated inverter B's rating - config.yaml's commented roster
example, DOCS.md's, and tools/supervisor_shape_probe.py's "a blob an operator
would POST" - and all three said 3000 W, a number nobody had measured or read
off anything. The owner supplied B's model and serial on 2026-09-04: a GoodWe
GW5048D-ES, serial `55048ESU22AW0992`, max charging and discharging power
4600 W. Serial characters 6-8 are `ESU`, platform 105 / AA55, so SPIKE-01 does
not gate this site. All three copies now read 4600.

⚠️ 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT, and the one ambiguity
is recorded rather than guessed. The datasheet prints it under BATTERY INPUT
DATA, so it is probably DC, while max_w is graded against 0x0518 - the
inverter's own AC power. If it is DC the AC ceiling is nearer 4324 W. Neither
reading is written in as fact; SAFETY-20's min(max_w, dev_max) already bounds
it correctly under either, once dev_max is read off the unit, so `max_w: 4600`
is what an operator should configure today. goodwe/NOTES.md §1.1b carries the
full record with the date and the method on every figure.

A NEW CHECK, BECAUSE A DOCUMENTATION FIX WITHOUT ONE DRIFTS AGAIN.
test_validate.py now pins all three documented rosters: findable, in agreement,
and equal to 4600 - with an explicit len(...) == 3 guard so that a regex which
stopped matching cannot leave "they all agree" green on the two sites still
read. It also grades the PROVENANCE beside the number (the datasheet, the
0x0518 it is graded against, and the 4324 W the DC reading would make it)
WITHIN 2500 characters of the roster rather than file-wide.

⚠️ The first version of that provenance check searched whole files and was
ALREADY VACUOUS on two of them: 0x0518 appeared once in config.yaml and once in
DOCS.md before this card, for unrelated reasons, so `"0x0518" in src` was green
no matter what happened next to B's rating. That is a check whose data cannot
reach the failure it names, in the file that exists to complain about them. It
is fixed, and the window is what fixes it - deleting the caveat beside the
number now goes red even where the same token survives elsewhere in the file.
The windowed version immediately found that the DOCS.md caveat did not name
0x0518 at all; DOCS.md now says it.

Four mutations, bytecode purged and counted at 0 before and after each, all
RED (two of them 0-byte deltas that change a printed answer):
  M1  probe's operator blob 4600 -> 3000        0 B   RED (value + agreement)
  M2  DOCS.md's DC/AC caveat deleted         -157 B   RED (provenance)
  M3  config.yaml alone 4600 -> 4324            0 B   RED (agreement)
  M4  probe entity renamed, regex finds nothing       RED (the vacuity guard)
Restored, green again. The probe itself was re-run against Supervisor
2026.08.0's own AppOptions validator with the 4600: all cases passed, exit 0.

⚠️ THE TEST FIXTURES KEEP 3000 W ON PURPOSE AND NOW SAY WHY AT THE LINE.
test_inverter.py, test_maintenance.py, test_peakguard.py and test_watchdog.py
build a second inverter at 3000 W against A's 5000 W. The only property those
checks consume is that B's number is unmistakably not A's, and the real pair is
a 400 W gap - narrower than slew_w, inside the range where an off-by-one-unit
bug and ordinary control arithmetic produce indistinguishable numbers.
Collapsing them onto the real values would buy realism those checks do not use
and cost them their separating power, which is exactly what test_peakguard.py's
own §10g PRECONDITION exists to prevent. Their comments no longer call 3000 W a
hypothesis about B's rating; they call it illustrative, and not a placeholder
either - the placeholder era ended on 2026-09-04.

Also recorded in the changelog for the cards that own them: 94 % battery-to-AC
=> ~88 % round trip => ~360 W burned continuously to circulate 3 kW, which is
the number SAFETY-31 argues its threshold from without having one; < 13 W night
self-consumption per unit, which nothing accounts for; and the A/B asymmetry in
opposite directions (~33 % more energy, ~8 % less power), which means MAINT-05's
12 h drain timeout was derived on A and should be re-checked against B.

⚠️ Honest survivors:
- goodwe/NOTES.md §1.1b, where all of this is actually recorded, is graded by
  nothing here. Rewriting its 16 occurrences of 4600 to 3000 and turning every
  FROM DATASHEET label into MEASURED ON THE UNIT leaves all 19 files GREEN.
  This CI cannot fetch admin/goodwe - private, and GITHUB_TOKEN is minted for
  this repository only, as .gitea/workflows/checks.yml already states - so the
  cross-repo check is not buildable here.
- No check can see whether 4600 is the RIGHT number. Everything above pins a
  datasheet reading against itself. Only the bench half of SPIKE-04 can say
  whether the unit agrees, and the DC-vs-AC ambiguity is the live example.
- The constant is still named B_RATING_HYPOTHESIS in four test files, which
  reads as a hypothesis about B's rating when it is now an illustrative
  fixture. It is left alone deliberately: renaming ~20 sites across
  test_peakguard.py and test_inverter.py would collide hard with the open
  SAFETY-32 pull request, which rewrites 1255 lines of the first. The comment
  directly above each definition says what the value is and is not.

Suite: 19/19 green in goodwe-addon-ci, mounted :ro, bytecode purged and
verified 0 before and after.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-04 22:19:31 +02:00