Release 0.18.2
Version bump to 0.18.2 and a CHANGELOG section for SAFETY-118 (#198). Co-Authored-By: Claude <noreply@anthropic.com> |
||
|
|
0ee3c3468b |
Release 0.18.1 review: CHANGELOG text fixes
SAFETY-118 line: the add-on already turns a kW forecast into W (main.py read_inputs, abs(raw) < 50), so only the settings-page warning is wrong. Rounding note and rows: the new settings page; UX-44 also changed one DOCS line. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
dec8e7b69f |
Release 0.18.1
Version 0.18.0 -> 0.18.1 (patch, no option changes) and a closed 0.18.1 CHANGELOG section. Co-Authored-By: Claude <noreply@anthropic.com> |
||
|
|
44cd1fde2a |
Release 0.18.0: review fixes to the CHANGELOG section
OPT-15 and OPT-20 rows: the retry is two inverters only, and OPT-20 no longer claims no other battery moves. SAFETY-111 added to known issues. MAINT-19 marked as from code reading. Wording fixes in the SAFETY-112 and MAINT-11 rows, UX-38 and the price service note. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
e7c83d3a57 |
Release 0.18.0: version bump and CHANGELOG section
config.yaml version 0.17.0 -> 0.18.0 and a closed ## 0.18.0 CHANGELOG section for OPT-17, SAFETY-112, OPT-15, MAINT-11, PRICE-01 and OPT-20. No code change. Co-Authored-By: Claude <noreply@anthropic.com> |
||
|
|
808ec04dc4 |
REL-0.17.0 review: CHANGELOG wording fixes
SAFETY-107 row names the tested base; MAINT-17 says code reading only; SAFETY-105 figure is from a simulation; SAFETY-97 edge is 175 W; the maintenance note cites MAINT-14 and MAINT-15; SAFETY-108 "about 15 s". Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
35432ce065 |
Release 0.17.0
Bump version to 0.17.0 and add the closed 0.17.0 CHANGELOG section. No code change, no option change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
1c607a961a |
REL-0.16.0 review: CHANGELOG wording fixes
SAFETY-103 swing 'by about 800 W for about 5 s'; SAFETY-99 'late, by less than 30 s'; MAINT-10 row: one-at-a-time is not new; SAFETY-96: drop the test-only 800 W; SAFETY-90 and MAINT-10 rows trimmed to two sentences. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
756b50ddbb |
Release 0.16.0
version 0.15.0 -> 0.16.0 and a closed ## 0.16.0 CHANGELOG section. No code change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
8c6e5bca2e |
Release 0.15.0: correct the SAFETY-94/97 row, add the ±170 W known issue
Review round 1 (F1-F3) on PR #173. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f01152b113 |
Release 0.15.0: bump version and close the CHANGELOG section
config.yaml version 0.14.0 -> 0.15.0 (minor: behaviour change from SAFETY-94/97, no option change). New `## 0.15.0` section with the contents since 0.14.0 ( |
||
|
|
f13dab1407 |
Release 0.14.0: changelog review fixes
Slew step not one house's 400 W; three two-inverter known issues, not four; commissioning reference covers a new install; SoC example holds for decimal sensors; SAFETY-95 states the jump, not the export. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
b307db1049 |
Release 0.14.0: version bump and changelog
Two inverters are now supported for maintenance and the peak guard (SAFETY-91, SAFETY-93). No option changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
b37b7f95dc |
REL-0.13.0 review: plainer, truer 0.13.0 changelog
Crash, not stop, for SAFETY-61; Watchdog off by default; its own warning for the 50 W peak margin (also under a higher month peak); "refuses power" for SAFETY-52/73; no one-house options claim. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
28cab03947 |
REL-0.13.0: cut 0.13.0
Bump config.yaml version 0.12.0 -> 0.13.0 and close a ## 0.13.0
CHANGELOG section covering every merge since 0.12.0 (
|
||
|
|
1ad4d3a5bb |
PKG-18: cut 0.12.0, so TEL-12's pv_entities can reach an installed 0.11.0
checks / unit (pull_request) Successful in 8m5s
One runtime merge since 0.11.0 (
|
||
|
|
b11bea70d3 |
PKG-17: the SAFETY-57 correction pointed at the wrong paragraph
checks / unit (pull_request) Successful in 8m13s
Self-review. The note added to `### SAFETY-57` said the reading rule it is qualifying is "two paragraphs up"; it is in the paragraph directly above - the same one the note follows. A changelog that misdirects a reader to a paragraph that is not there is the small end of exactly the defect this cut is fixing three sentences of elsewhere, so it is corrected rather than left. Text only, one line pair, still two files in the branch's diff. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
cfafdffaed |
PKG-17: cut 0.11.0, so SAFETY-56's wording fix and TEL-11's pv_entity can reach an installed 0.10.1
checks / unit (pull_request) Successful in 8m0s
Two files, and no third. config.yaml 0.10.1 -> 0.11.0; CHANGELOG.md gains `## 0.11.0` and three corrections to sections below it. A MINOR BUMP, NOT A PATCH. TEL-11 adds an option - `pv_entity`, 75 keys -> 76 in `options:` and `schema:` together - which is the same test 0.8.0, 0.9.0 and 0.10.0 were cut on. Nothing here can refuse a stored blob: the key is `str?` with an `options:` default of "", validate.py does not mention it, no default moved and no enum widened, so a blob that starts the add-on on 0.10.1 starts it on 0.11.0. THE TABLE HAS TWO ROWS AND THE WINDOW HAD FOUR MERGES. CI-9's follow-up ( |
||
|
|
eb88646899 |
PKG-16: cut 0.10.1, so SAFETY-57's fix can reach an installed 0.10.0
checks / unit (pull_request) Successful in 8m0s
The Supervisor decides an update exists by comparing config.yaml's version string with the one the box reports. master and release/1.0 both said 0.10.0, so SAFETY-57 - a deadlock that parked the reference battery for ~13 min on 2026-09-21 while the house exported 2.4 kW - had no way of reaching the box that has it. A patch bump is the delivery mechanism, not bookkeeping. - config.yaml: 0.10.0 -> 0.10.1. Nothing else in the option surface moves: no key added or removed, no default changed, no enum widened, no rule added to validate.py, so a blob that starts on 0.10.0 starts on 0.10.1. - CHANGELOG.md: a new `## 0.10.1` section, holding SAFETY-57's entry moved out of `## 0.10.0`. The entry opened by saying it was misfiled and that whoever cut the next version owned moving it; this is that cut, so that paragraph is replaced by what an operator actually needs in order to decide - what the deadlock does (command parked at 0 W, batt reading gated to MISSING, escape condition unreachable from inside the state), how to recognise it (setpoint stuck at exactly 0 W with the battery register flat, a STALE line and no clearing line) and that a restart of the add-on clears it. - PKG-16 proper: `## 0.10.0`'s preamble still claimed 0.10.0 "has never been built or pulled anywhere" and that the reference install was on 0.7.0. Both stopped being true on 2026-09-20 ~22:18 CEST, when 0.10.0 was installed as a repository add-on (slug 68285ac7_goodwe_controller) and began regulating a real battery. The section's own bump argument was explicitly conditional on that; the condition has fired, so the argument is retold as history and the section is closed. This text is what the Supervisor shows beside Update. Also fixes, in this file only, the three non-blocking documentation defects raised on PR #104 - issuecomments 1445, 1446 and 1447: - 1446: the live episode is 790 s, not 710 s. Re-derived rather than rescaled: at >= 790 s the committed 16-day replay gives 16 of 93, not 17. - 1447: the BMS keep-alive pulse was an inference stated as a measurement. No committed capture identifies one, and on this episode 0x0518 never moved at all. The measured claim replaces the firmware story. - 1445: "neither consumer can reach a verdict inside one window" is universal as written and graded on a fixture that puts the obligation back on every release. It now carries the qualifier the reviewer asked for, and names the unbounded case and why the shipped one-inverter roster cannot reach it. The same three defects also sit in app/freshness.py, test_freshness.py, DOCS.md and the DECISIONS note. They are deliberately NOT touched here: this PR is config.yaml and CHANGELOG.md only, and none of them is worth delaying a live safety fix. SAFETY-56 and SAFETY-58 are likewise untouched. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
43c144b8d9 |
SAFETY-57: the stale-reading verdict gets an exit, because its own consequence is what stopped it being tested
checks / unit (pull_request) Successful in 7m58s
SAFETY-37's freshness gate reports a battery-power register as MISSING when it
stops following its own command, and a missing input is "command 0 W and keep
commanding" (§11.1 rule 1). The gate's only exit was "an arrival carrying a
DIFFERENT number" - and at 0 W nothing is asking the register to be anywhere.
The state had no exit reachable from inside it, and the log line promised the
opposite in the same sentence that announced the 0 W.
REPRODUCED FROM THE WIRE, NOT MODELLED. scenarios/safety57-2026-09-21/ is 3840
verbatim frames off the RS-485 pair, read from the passive sniffer, decoded by
tools/decode_bus_capture.py (0 unparsed, 0 bad CRC, 0 unknown shapes; the
mode->sign convention is graded off the capture, not trusted). The box was
running 0.10.0, so the 0 W in the trace IS the add-on's own claim:
10:51:24.7 0x0518 reaches -3 W. Pack at 11 %, the BMS refuses the discharge,
the inverter idles. THE REGISTER IS HEALTHY AND TRUTHFUL.
10:51:29.7 the command reaches +1060 W - 800 W of travel
10:52:00 the conjunction arms. Inverter.batt becomes None
10:52:21.7 the site commands 0 W, on the wire
... 0x0518 does not change value for 850.0 s. The setpoint does not
change value for 790.0 s. The house exports 2.4 kW throughout
~11:04 a human restarts the add-on. That is what ends it
AND IT HAD BEEN ESCAPING BY LUCK. Replaying the committed 16-day loop capture
through the shipped conjunction finds 93 trips whose wait for the BMS
keep-alive pulse that cleared them has a median of 143.4 s, a worst case of
21440.1 s, and 17 of 93 at or beyond this episode's 710 s. That distribution
belongs to the battery's firmware, not to this code.
THE CARD'S OPTION 2 ALREADY HELD AND IS NOT THE BUG. _grade() has required
|standing| >= MOVE_W since SAFETY-37. The trip was at +1060 W and the stuck
state is at 0 W; they are different moments, and an entry-side rule cannot
reach a state entered legitimately and then persisted. Nothing in the
conjunction is weakened here.
THE RULE, SAFETY-13's SHAPE ONE MODULE OVER - which latches get an exit, not
how long the block lasts:
the verdict is withdrawn when the obligation that produced it has been gone
for RELEASE_S, and the register is then re-graded from scratch.
RELEASE_S is BATT_OBLIGED_S, 17.0 s - the obligation window already derived in
the file (6.0 plant + 10.0 publish + 1.0 read), taken at the FLOOR of its band
for the mirror of MOVE_W's reason. Which half is safe is the opposite of
SAFETY-13's: being wrong long is the failure being fixed, being wrong short
costs one bounded re-grading window. Below 17 s the release pre-empts the
cheaper exit - the register answering by itself - and that is graded
behaviourally, not asserted.
The whole parked interval is now stale_input_s + RELEASE_S = 32 s. On the live
episode: telemetry back at 10:52:39 instead of 11:05:35, with 0x0518 still
answering the same -3 W. RED BEFORE (release_s=inf, a graded counterfactual and
not a second implementation), GREEN AFTER.
WHAT IT COSTS, AND IT IS NOT SMALL. A register dead for good is re-graded for
ever: over 1201 reads the held number reaches a consumer on 630 (52.5 %)
against 35 (2.9 %) before. Payable only because one window is at most 35 s and
the two consumers hold for 75 s and 85 s, so neither can reach a verdict inside
one and the re-trip clears both windows. No detection SAFETY-37 had is given
back - a permanent None clears the same windows for ever too - and the command
is derived from the P1 meter, never from batt.
Two clocks, deliberately: changed_mono/unchanged_s() stay facts about the
REGISTER, graded_from/graded_s() are the VERDICT's window. Collapsing them
either lies to the operator or defeats the re-grading.
main.py's stale line had its ESCAPE CLAUSE corrected - it promised a clearance
the state could not produce - and gained a STALE WITHDRAWN edge that says in
its own words that nothing has been learned about the register. The DIAGNOSIS
half is SAFETY-56's and is deliberately untouched, with a named check asserting
it is still there so that rewrite has to be deliberate.
Battery: 22 mutations, 21 red, 1 argued equivalent, 0 unexplained survivors.
Two findings kept in DECISIONS: _release()'s move_w test swapped for
unchanged_s SURVIVED at +5 B because every fixture rested at exactly 0 W (habit
11, closed by a 0/100/300 W fixture); and the code shipped a habit-22 comment
claiming the _release/_grade order was load-bearing, which the battery
falsified - the two act on mutually exclusive predicates, so the order is not
observable. MUTATION.md gains habit 23 for a mutation that ran, fingerprinted
clean, and was a no-op on the fixture because `0.0 or x` is x.
Suite: 30/30 in the CI image, checks.yml's exact command, purged tree, :ro, one
file at a time.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
5aba220046 |
PKG-15: fold TEL-10 and SAFETY-48 into 0.10.0, so the version names its contents
checks / unit (pull_request) Successful in 7m53s
0.10.0 was cut by PKG-14 on 2026-09-16 and three tickets have merged into release/1.0 since. Two of them change the built image - one is a CONTROL LAW change and one adds three MQTT entities - and neither is described anywhere in this file. Tagging that tree today would stamp a number on contents the changelog does not account for. FOLDED RATHER THAN CUT AS 0.11.0, AND THE ARGUMENT IS CONDITIONAL. 0.10.0 has never been built or pulled anywhere: the reference install is on 0.7.0 (PKG-14's own predeploy run records `deployed on the box : 0.7.0`), the repository carries exactly one tag, `v0.2.1`, and no release. So the string `0.10.0` does not yet name a tree anyone is running, and the PKG-06/PKG-07 no-op that forbade re-cutting `0.9.0` does not reach it. Cutting 0.11.0 would burn a number on a release that never left the repository. The condition is checkable and the section now says so: run against a box already reporting 0.10.0, `tools/predeploy_check.py` refuses with THE DEPLOY WOULD BE A NO-OP and names the runtime commits since the bump. `config.yaml` stays at 0.10.0, so `test_version_gate.py` 11b still finds the two sides equal. SAFETY-48 IS THE ENTRY THAT MATTERED MOST TO GET RIGHT, AND WHAT IT PROMISES IS LESS EXPORT - NOT A LOWER BILL. The measured result is export 39.61 -> 34.07 kWh over the committed 16-day replay, 14 % of the replayed figure, falling at every plant and tuning variant swept (~4 % to ~16 %, median near an eighth). The section says in its own heading and its first line that the control law changed, and it says PLAINLY that the billed quarter is not a claim: at every plant lag <= 5.0 s - including the one that best reproduces the recorded export - release/1.0's worst quarter is ALREADY 3434 W and this changes it by exactly zero. The 3739 -> 3434 W headline exists at the single longest fitted lag, and the lag is not identified by the recording. The costs are in the entry too: the cap moves a saturation-frozen integrator on 1095 of 79 160 frozen ticks, 679 of them outward; SAFETY-13's settle values moved; SAFETY-39's "the slew does not own the over-absorption" is now false. TEL-10 gets the three site rows, what each one is, and the two things a reader would otherwise get wrong: the lead is NOT a subtraction of two published rows, and `Loop reason` is not the `Why` row. It repeats neither of the two sentences TEL-10's own review retracted - EIGHT messages stay first and the ninth, `goodwe_ctl/availability`, is byte-identical but deliberately moves to last. CI-9 IS DELIBERATELY NOT IN THIS FILE, AND THE OMISSION IS WRITTEN DOWN RATHER THAN SILENT. It changes one file, `.gitea/workflows/checks.yml`, outside `goodwe_controller/` entirely: not in the built image, not in `is_runtime()`'s list, and not observable on any version of the add-on. This file is the release note the Supervisor shows beside the version number, and a row here has to be something the person deciding whether to press Update could act on. The note above SAFETY-48 says so and says the rule is about audience, not importance. THE STRAY `## Unreleased` AT LINE 1777 IS NOT TOUCHED, AND THAT IS A DECISION. It is the 0.8.0-era block PKG-14 annotated: every row in it has shipped, the annotation says which release each went to, and re-filing it is PKG-08's card. It is also load-bearing - `test_version_gate.py` 11d pins the count of `## Unreleased` blocks below the newest section at EXACTLY one, so deleting it is red on the commit that does it, and so is adding a second. TWO MEASURED FIGURES IN PKG-14'S PROSE WENT STALE AND ARE RE-DERIVED, NOT ADJUSTED. The runtime-commit count since `86bdf49` is now 32, not 28, of which the contents table accounts for 24, not 21; both re-run through `predeploy_check.is_runtime()` itself. The other eight are the three misfiled tickets (SAFETY-43 x2, SAFETY-44 x3, TEST-21 x2) and `cb3f686`, PKG-14's own bump, which edits `config.yaml` and so counts as runtime - it was HEAD when PKG-14 measured and is inside the range now. PKG-14's `CLEARED, exit 0` predeploy transcript was NOT re-run and now carries the check that says why it still holds: `config.yaml` is untouched by both tickets; `app/validate.py` imports neither `main` nor `mqtt`, and the three names it takes from `control` - SLEW_RAIL_FRAC, LOOP_TICK_S, PLANT_SETTLE_S - are byte-identical across cb3f686..HEAD. Verified: the full suite in the CI image, `cp -a` of the tree, purged, `:ro` mount, one file at a time, exactly the command in .gitea/workflows/checks.yml - 30/30, exit 0. No runtime file is in this diff. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
cb3f686555 |
PKG-14: cut 0.10.0, and say what an upgrade from 0.7.0 crosses
checks / unit (pull_request) Successful in 7m51s
`config.yaml` 0.9.0 -> 0.10.0, and the top `## Unreleased` block is closed
into `## 0.10.0` with a preamble that names the backward-incompatible
changes and who they reach.
MINOR, and NOT because eighteen tickets landed. A stored options blob the
previous version started on is REFUSED on this one:
* TARIFF-07 retires three `price_provider` ids; a site set to one is
refused BY NAME at startup. Measured on the reference blob, with a
control on an accepted id so the refusals are about the ID.
* TARIFF-18 moves `price_taxes_eur_kwh` 0.06 -> 0.11736. A site that
STORED 0.06 is untouched, and - the non-obvious half - a taxes period
table beside that stored 0.06 does NOT become a startup refusal on
upgrade, because `SUPERSEDED_TAXES_DEFAULTS_EUR_KWH` reads it as
untouched. Measured, with the counterfactual that the rung is not
weakened (ORES's 0.1198 is still refused).
* SAFETY-10 adds `shadow_mode`, shipped `auto`. An existing CONTROLLING
install does not change by one watt and a FRESH one comes up observing.
Measured cross-revision,
|
||
|
|
e3ccd9f6ea |
SAFETY-47: what a shadow run can show, and the watts on its status row
checks / unit (pull_request) Successful in 7m48s
Not a leak and not a write-path defect. Shadow mode's safety is intact -
the substitution, the re-seed, the authorisation gate and the clamp are
untouched. What was wrong is what three merged documents SAY a shadow run
can show you, and a number on the status row that can be 6.61x what a live
controller would command.
SHADOW MODE CANNOT SURFACE A CLOSED-LOOP DEFECT, AND THE DOCUMENTS NOW SAY
SO. The battery is held at 0 W and the carried command is re-seeded to it,
so every measured input - the meter, the billed-quarter accumulator behind
it, the battery power, the SoC - describes a plant that did not respond. A
closed-loop defect is one whose stimulus IS that response. This is the same
property that makes shadow mode safe, so it is not a gap to close later:
the closed-loop answer comes from the closed-loop rig or from a live run.
SAFETY-10 §5 already conceded this for the grid-following loop. It was
never the loop leg's limitation; it is the general case.
THE "STRATEGIES ARE UNAFFECTED" EXEMPTION WAS TRUE UNTIL SAFETY-45 MERGED,
ONE COMMIT EARLIER. That card sizes the buy leg as min(asked, headroom)
with headroom = (900/remaining) x (ceiling - projected), and `projected`
reads the open quarter's accumulator - the meter - which is a function of
what the battery did earlier in that quarter. Measured on TEST-23 stage 3
at peak_cap_w 1500 / house 1200 / max_w 2000, one hour at 5 s:
SAFETY-45's limit cycle NOT visible. 28 onsets live vs 1; grid
-455.5..+3200.0 W vs flat at the 1200 W house;
guard engaged 410/720 cycles vs 0/720.
SAFETY-46's SoC churn NOT visible. The SoC moves 0.000000000 pp.
TARIFF-14's wrong hour VISIBLE, and it is the only one: which hour, at
what price, clearing what spread - identical on
720 of 720 charging cycles at a binding cap.
The exemption narrows to exactly what survives: WHICH hour a strategy picks
and WHY are unaffected; HOW HARD it trades is not. The peak guard's ceiling
and reasons are worth reading from a shadow run; its ENGAGEMENTS are not.
THE NUMBER IS CAVEATED, NOT RE-COMPUTED, AND THAT IS THE DECISION. The
arithmetic is not wrong - 900/remaining is correct for a meter genuinely
under the ceiling, and in shadow the meter genuinely is. It is the right
answer to a question nobody asked. Both surfaces now introduce the watts as
what would have been commanded ON THIS CYCLE, in every state, and carry
shadow.SIZED_FROM_METER whenever a measured billed quarter sized them.
Rejected, and recorded in the decision doc: re-computing it (the recorded
decision would no longer be the decision the shipped path reached, while the
arbiter, clamp, SAFETY-28 gate, log and MQTT all ran on the real one - a
second controller everywhere except the wire); recording nothing (blanks the
row exactly when arbitrage is trading, and the log's edge key is the watts);
and recording the unsized ask beside it (a second number, no warning, and at
the shipped 3500/2000 both figures read 2000 W).
"UPPER BOUND" AND NOT "SMALLER", AND THE DIFFERENCE WAS MEASURED. Charging
only adds offtake, so the shadow size is >= the live size with EQUALITY at
the start of every quarter. Pairwise over 3600 charging cycles in five
configurations: 0 below, 730 exactly equal. The first draft said "smaller",
which would have been false on every one of those 730.
AND THE PREDICATE IS NOT KEYED ON WHETHER THE TRADE WAS CAPPED. arbitrage's
own sentence says "SIZED BY THE CAPACITY-TARIFF GUARD" only when the
headroom came out below the ask - in a shadow run, the START of the quarter,
where the two runs agree to the float. By the end, 900/remaining has
multiplied the headroom past the ask, the trade is not capped, the sentence
is silent, and the record is at its most wrong. A caveat keyed on it would
be quietest exactly where it is needed loudest.
SAFETY-10 §6's COMMITTED EVIDENCE COULD NEVER HAVE FAILED, FOR TWO
INDEPENDENT REASONS, AND CLOSING EITHER ALONE CLOSES NOTHING. Its fixture is
peak_cap_w 15000 against a 350 W house, so the guard never engages and the
sizing is inert - the harness's own comment says so. AND every identity row
reads the FIRST charging sample, where at elapsed=0 the projection IS the
held level and the two runs agree to the float even at a cap that does bind.
Measured: widening the fixture alone leaves that comparison passing. That
second reason is a new shape for MUTATION.md's habit-4 list - an INDEX, not
a fixture - and it is recorded there as the twelfth instance. §6 is re-taken
at a binding cap across the whole run: 716 of 720 charging cycles differ,
headroom 300.0..54000.0 W in shadow against 299.9..307.8 W live, recorded
-2000.0 W against a live -302.4 W.
THE GRADER IS test_arbitrage.py PART 3d, beside SAFETY-45's own closed-loop
regression and built on the same s45_loop() harness, so the runs differ in
one argument. Three lines stand in for _write_unit()'s substitution and
_shadow_settle()'s record and re-seed, marked as a transcription;
test_clamp.py part 8 remains the check on the shipped placement. The section
carries its own precondition into every check: a mutation that stopped
either run trading made it raise on its first min(), kill the file and
report ZERO reds - FCST-06's shape, driven rather than imagined.
AND THE FIX'S OWN FIRST DRAFT CARRIED THE SAME DEFECT. Deleting the caveat
from the action-log line left all 29 files green, because the sentence was
an f-string inside _shadow_settle() and the only suite that drives it uses a
meter_source:off fixture where no arbitrage decision exists. It is
shadow.log_line() now, for the reason words() is a function.
14 mutations, no survivors; M13 and M14 are +0 B and were confirmed on disk
by sha256 with every run purged. M14's first form was aimed at the wrong
direction and correctly survived - min->max makes the shadow record larger,
which is still an upper bound. All 29 check files green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
8fa4febfef |
SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside while it was happening, and each was paid for at the meter first: SAFETY-45's 28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain 310 Wh. There was no way to watch what the optimiser WOULD do without letting it do it. `shadow_mode` runs strategies, arbiter, clamps and guards, records the decision with its reason, and commands nothing. ⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary single writer. The inverter holds its last command forever - it has no meter timeout - so "commands nothing" implemented as "stops writing" would leave whatever was standing when shadow mode came on standing for as long as it was left on, under a page saying nothing is being commanded. That is the failure this repository keeps finding. Refreshing 0 W is also what firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going quiet would keep that board tripped for the whole run, which is an alarm being used as a mode. ⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its own. It is a substitution inside Controller._write_unit() - the single choke point every write already reaches - in the same form as the three above it, and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still grade the number the decision path produced. ⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The Supervisor composes options as {**config.yaml defaults, **stored user options}, so a new key with a new default reaches EVERY EXISTING INSTALL on the next update - including the one regulating a real battery. A boolean default-on would have stopped it silently. There is no mechanism by which one key can default differently for a new install and an existing one, so "default-on for new" is a value the add-on RESOLVES: `auto` is shadow while control is STOPPED and live once it is STARTED. A fresh install ships `auto_start: false` and comes up observing; an install that is controlling is started and does not change by one watt. THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision they would disagree with a meter that never saw it and LATCH A TRIP THAT SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate (SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation (SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch, because their evidence is measured power. The operator stop is the one deliberate change: enforced at the wire rather than as a P_SAFETY claim, which would otherwise make every recorded decision read "stopped". ⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what stands on the wire, which makes the exit safe by construction - and therefore the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow run answers "what would it command now", not "what would it have done next". The strategies are unaffected; all three defects above are visible from one. Graded on the writes and on the rendered surface, never on the flag: 22 mutations, no survivors, including one that lets a write escape and one that goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig, same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %; shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage decision is identical in action, instant, signed power, reason and arbiter winner. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e1b9254626 |
SAFETY-45: a price-driven charge is SIZED by the capacity guard, not switched by it
checks / unit (pull_request) Successful in 7m42s
With arbitrage armed at the shipped defaults, arbitrage and the capacity-tariff guard drove each other in a sustained limit cycle. Re-measured on TEST-23 stage 3's closed rig against |
||
|
|
995da777ce |
TARIFF-16: the injection leg stops being one number
checks / unit (pull_request) Successful in 7m42s
`price.py` modelled what a site is PAID for export as ONE scalar. The market publishes a line, and the cards say so in their own words: Eneco Zon & Wind Dynamisch `0,1 x BELPEX-H - 1,188` c EUR/kWh - "het injectietarief is dynamisch en kan per uur wijzigen", identical on the January and the September 2026 cards; ENGIE Dynamic `(B x eSpot_15) - A`; Aspiravi `0,07 x Belpex - 2`. `price_export_formula` carries that line with its OWN coefficients. ⚠️ THIS IS NOT A WRONG-TRADE FIX, AND SAYING SO IS PART OF SHIPPING IT. `arbitrage.py` does not read `export_price_eur_kwh` at all - its own comment says so, citing §9.3's near-zero Belgian injection price as the reason the economically sound trade on this market is charge-cheap-to-displace-expensive- IMPORT. Both hours it compares are all-in CONSUMPTION prices. No trade this add-on takes today is decided by an injection price and nothing here changes one. What it changes is what an operator is told, and what a future export-aware strategy rests on: OPT-06 and any export logic would otherwise inherit a scalar that cannot represent the market, and the 6% VAT asymmetry would be invisible in the arithmetic. test_price.py 17h parses every module under app/ and goes red the day something calls an injection reader, so that sentence is graded rather than attested. FOUR PROPERTIES A SCALAR CANNOT HOLD. Its own factor (Eneco 0,102 consumption against 0,100 injection; Aspiravi 0,07 against ~0,10 - not the consumption B with a sign flip). A negative offset, which `price_markup_eur_kwh: float(0,1)` cannot express at all. VAT-exemption - "injectietarieven zijn vrijgesteld van btw" - against 6% on consumption, representable only because `vat_pct` is PER SPEC. And a price that goes below zero with no floor, under 11,88 EUR/MWh of BELPEX-H, which is the middle of a sunny day. ⚠️ A NEGATIVE INJECTION PRICE IS ACCEPTED, AND THAT NEEDED A DIFFERENT BAND RATHER THAN A LOWER FLOOR. `implausible_all_in()` floors the consumption leg at +0.02 EUR/kWh of energy; applied to injection that refuses the real market in the hours it matters most. Measured rather than argued: 17c puts ONE spec through BOTH bands and prints that the consumption band refuses -0.03008 EUR/kWh while the injection band accepts it. The floor was not decoration - it is what catches a card read a hundred times too small, the one unit error the card self-check cannot see because it cancels out of a comparison between the two sides - so the bound moves OFF the price and ONTO the coefficients, where it is index-free and sign-free: a pass-through band (Eneco's injection leg is 1.00x, Aspiravi's 0.70x; the band is 0.10-10x) and an offset magnitude bound (0.20 EUR/kWh against published 0.01188 and 0.02). Two rungs that can both answer a hundredfold error, so each is graded on its REASON, each gets a stimulus the other cannot reach with the precondition asserted as its own check, and they are mutated TOGETHER (TEST-16). ⚠️ THE CARD SELF-CHECK APPLIES WHERE THERE IS A CARD, AND WHERE THERE IS NOT THAT IS STATED RATHER THAN WORKED AROUND. `price_formula` can require a `card` block because a Belgian card prints the consumption formula, the reference index AND the resulting price. Eneco's INJECTION formula is printed with no price beside it. Requiring a block would make the published line inexpressible; inventing the estimate would grade the coefficients against arithmetic done with the same coefficients. So the block is OPTIONAL on this leg and unchanged on the other, the self-check runs at the same tolerance wherever a printed estimate exists, and validate.py says at startup - "its coefficients are UNGRADED" - when it does not, naming the two bounds that ran instead. This is TARIFF-15 demonstrating two tariffs end to end rather than three, one card later. 17e also MEASURES the size of that gap: a factor of 0.070 where the contract says 0.100 - 30% of every export payment - passes both bounds, because 0.70x is a pass-through somebody really publishes. ONE PARSER, NOT TWO. `parse_export_formula()` is `parse_price_formula()` with its OPTION NAME as an argument - TARIFF-17's move on `parse_static_profile()`, exactly - and everything that differs between the legs is a string in one `_LEGS` table. A second copy would be a second unit table, a second NaN rule, a second unknown-key rule and a second `to_resolution()`, diverging first on the 23- and 25-hour days. test_price.py 17b pins it two ways: all 32 grammar names are defined in exactly ONE module under app/, with the scope COMPUTED by parsing every file rather than listed; and twelve refusal sentences for the new option are DERIVED from the old option's own sentence rather than transcribed. The four sentences that deliberately differ are named, with what differs, and asserted to differ. NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships ""; `export_price_eur_kwh()`'s body is byte-identical, pinned on the AST rather than on the source text; `export_price_at()` falls through to it for every index value. 17f compares seven option dicts x five index values against the pre-TARIFF-16 expression with `==`. `price_export_formula` joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is derived from that set, and `code_leaks()` refuses a plugin that names it with nothing else edited. ALSO CORRECTED HERE: config.yaml's comment beside `export_price_eur_kwh` still read "no shipped supplier publishes a dynamic injection curve". TARIFF-07 struck that claim from app/price.py and DOCS.md and did not reach config.yaml, where it has been shipping since. 20 mutations, every one red on a named check, ledger in test_price.py below section 17 - including a ZERO-byte one (the two legs transposed in the VAT-asymmetry banner: no decision moves, only the sentence) and a ONE-byte one (`card_required=True` on the injection leg). Three run over all 29 files and red on test_price.py alone. 29/29 green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
9c65ac2cf8 |
TARIFF-18: price_taxes_eur_kwh stops shipping at half the real figure
checks / unit (pull_request) Successful in 7m48s
`price_taxes_eur_kwh` shipped at 0.06 EUR/kWh with no recorded provenance -
no card, no date, no component list - and roughly HALF the true Flemish
all-in non-energy figure. It now ships at 0.11736, and the rows it is made
of are in the code rather than in this message:
Fluvius distribution (Antwerpen) 5,35 c EUR/kWh
Bijzondere accijns, "Alle verbruik" 4,876
Bijdrage groene stroom en WKK Vlaanderen 1,51
Energiebijdrage (0 EUR/MWh since 2026-08-01) 0
------
11,736 c EUR/kWh = 0.11736
Eneco residential card for Flanders, September 2026, incl. 6 % VAT.
`app/price.py`'s FLEMISH_TAXES_COMPONENTS_EUR_KWH carries the rows and
test_price.py section 1b re-adds them - and also compares the total against
the card's own figures typed in the test file, so an edit that moved the
rows and the default together is still caught.
WHAT THIS IS NOT. It is not an arbitrage-correctness fix and it cannot be.
This scalar is a LEVEL component: an additive constant cancels exactly in
`max - min` and leaves the argmin where it was. TARIFF-17 shipped that proof
and it is unchanged - test_price.py 16b drives six flat scalars spanning and
exceeding the whole per-DSO range and gets the identical cheapest hour and
the identical spread to the last digit. DOCS and the CHANGELOG say so in
those words.
WHAT IT IS. A display and guard fix:
* every number an operator reads, which at half the true value made the
add-on look considerably better than it is; and
* §17's negative-price guard in arbitrage.py - the one rung that tests an
ABSOLUTE all-in price rather than a difference. It fires when
`spot < -(markup + taxes)`, so its boundary moves -0.09 -> -0.14736
EUR/kWh of spot. test_arbitrage.py section 2c drives both sides through
the shipped decide() and pins the boundary from below as well.
The default is Antwerpen's real row, near the LOW end of the 0.117-0.131
per-DSO band, and that is deliberate: the error directions are not
symmetric. Too high carries a genuinely negative hour above zero and the
add-on exports into paid-for disposal - §17's own case. Too low only
declines a discharge that would have paid.
TARIFF-17's INTERACTION, WHICH HAD TO BE DECIDED. Nothing in that rung
hardcoded 0.06; it read PRICE_OPTION_DEFAULTS, so moving the default moves
what it refuses. The Supervisor sets `App.options = deepmerge(config.yaml
defaults, stored options)`, so a saved blob carries the key whether it was
typed or not - every stored 0.06 became "non-default" with nobody editing
anything, and a working Walloon or Brussels site with a taxes table would
have met SystemExit(78) on the upgrade over an inert number. price.py now
carries SUPERSEDED_TAXES_DEFAULTS_EUR_KWH = (0.06,) and validate.py reads a
superseded default as untouched too. The rung is NOT weakened: 0.1198 beside
a table is still refused by name, and the refusal now names both figures.
config.yaml and PRICE_OPTION_DEFAULTS moved together; CFG-03's tripwire
(test_price.py section 1, test_defaults_pin.py) stayed green by agreeing.
test_price.py section 0's fourth check was REWRITTEN rather than re-pointed:
it used to justify the file's own grading constants by observing that the
shipped pair was degenerate (0.06 is exactly twice 0.03). TARIFF-18 ends
that coincidence, so the sentence is no longer true and is not kept.
29/29 test files green. Mutation ledger on the PR.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
2fac0aaf06 |
TARIFF-17: a price component that varies by hour has somewhere to live
checks / unit (pull_request) Successful in 7m25s
`price.py` modelled the whole non-energy part of a Belgian bill as ONE flat scalar. This adds `price_taxes_profile`, which carries the TAXES component as a period table, and makes `assemble()` evaluate it at each point's own instant. ⚠️ THE FLAT SCALAR WAS NOT A WRONG NUMBER, AND THIS IS NOT A CORRECTION OF ONE. The optimiser reads exactly two quantities off a series - the spread `max - min` over the firm points, and which hour is cheapest - and an additive constant identical in every hour cancels out of the first and leaves the second where it was. It is provably inert. Measured, and printed by test_price.py 16b on every run: with a flat taxes figure of 0.00, 0.0739, 0.1198, 0.1327 or 1.00 EUR/kWh the same 24-hour feed is cheapest at 13:00 in all five cases and its spread is 0.1500 EUR/kWh in all five cases. What was missing is anywhere for an HOUR-VARYING non-energy component to live. This is a missing capability, not a bad constant. Belgium has one. Fluvius distribution is a single rate - its tariff-card row reads `Normaal | Uitsl. nacht`, where exclusive night is a separate physical circuit and not a night register - so nothing changes for the reference site in Flanders. The Walloon DSOs and Sibelga are on the same card with four columns, `Enkelvoudig | Dag | Nacht | Uitsl. nacht`, and the gap is real money (c/kWh): ORES 13,27 / 7,39; AIESH 15,17 / 8,21; Tecteo RESA 12,20 / 7,01; Sibelga 9,39 / 7,10; ORES IMPACT 2026 16,578 / 5,090. ⚠️ AND THE BANDS ARE ANTI-CORRELATED WITH WHAT THE BATTERY WANTS TO DO. The cheap network hours are the cheap spot hours, so flattening them does not shift the curve - it UNDERSTATES the spread and declines cycles that would have paid. Same feed, same markup, the only difference being the taxes argument: flat 0.0000 / 0.0739 / 0.1198 / 0.1327 / 1.0000 -> cheapest hour 13, spread 0.1500 ORES dag 0.1327 / nacht 0.0739 -> cheapest hour 03, spread 0.1788 The regression check grades WHICH HOUR IS CHEAPEST, not the spread: an implementation that reads the table once and adds one number to every point is the LEVEL bucket wearing a period table - right magnitude, wrong shape - and a spread assertion passes on it. Measured: hoisting the lookup out of `assemble()`'s loop (+17 B) is red on six named checks in test_price.py and GREEN in the other 28 files. ONE GRAMMAR, NOT TWO. `static_tariff.py` already shipped the periods, the day selectors, the tiling rule and the DST handling, so `parse_taxes_profile()` is the same parser with the option name and the "what this number means" clause as arguments. A second tiling rule would be a second set of 23- and 25-hour-day bugs. test_static_tariff.py section 10 pins that two ways: by parsing every module under `app/` and asserting the grammar is defined in exactly one of them, and by deriving each of thirteen refusal sentences for the new option from the old option's own sentence rather than transcribing them. `Component.TAXES` semantics, `code_leaks()` and the double-counting guarantee are untouched. The new key joins FRAMEWORK_KEYS, BANNED_IN_PLUGIN_CODE is derived from that set, and a plugin that names it is refused at `register()`. It reaches both plugins that take taxes - `custom_formula` ({ENERGY, MARKUP}) and `generic_dayahead` ({ENERGY}) - and not `manual_csv`, which is all-in: the table is routed through `capabilities().adds`, exactly as the scalar is. ⚠️ A MALFORMED TABLE IS REFUSED AT STARTUP, NOT AT THE NEXT FETCH. It is read on the ~30 s planning path, and a table that first fails at 03:00 is a site that stops pricing at 03:00, which §11.4 turns into a quiet fallback indistinguishable from a healthy fixed-tariff day. validate.py refuses three things: a table that does not tile the day; a table set beside a NON-DEFAULT `price_taxes_eur_kwh`, because the table wins and the scalar would then be a number the operator typed that decides nothing; and a whole card typed in CENTS, which is how these figures are printed. That last rung is not a restatement of the parser's +-10 EUR/kWh bound - ORES's 13,27 trips the parser, but Sibelga's entire card, 9,39 and 7,10, is under it and would otherwise have started as a 9.39 EUR/kWh levy. Both rungs are graded by the REASON each gives, and mutating them together (TEST-16) moves three rows. NOTHING CHANGES FOR A SITE THAT DOES NOT SET IT. The option ships "", and the scalar path is unchanged arithmetically rather than merely in intent: test_price.py 16f reproduces the pre-TARIFF-17 expression and compares 12 capability/scalar combinations point for point with `==`. 13 mutations, every one red on a named check, ledger in test_price.py below section 16k with byte deltas and the one equivalent mutant named. 29/29 green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
a11597e0b3 |
Merge remote-tracking branch 'origin/release/1.0' into TARIFF-11
checks / unit (pull_request) Successful in 7m20s
# Conflicts: # goodwe_controller/CHANGELOG.md |
||
|
|
610725bed9 |
TARIFF-11: the plan's account of itself, corrected and put on the page
Four defects of one shape - the add-on's report of its own tariff plan was wrong, always in the direction that flattered it - and one check, which is the deliverable. 1. `TariffPlan.words` counted POINTS and called them HOURS. The live add-on logged `dynamic_dayahead from generic_dayahead, 132 h` for 132 quarter-hourly points = 33 hours. Belgium moved to a 15-minute MTU on 2025-10-01, so this was wrong every time it was printed, and NOT by a constant factor: a 40-hour soak measured 1.79x .. 5.33x, because §8.3's carried points are hourly while the firm ones are quarter-hourly. `words` now reports both quantities, plus the firm/carried split and the spacing, in FCST-04's *Price history* wording so the two rows can be compared. 2. §8.3's firm-pair refusal and the flat-tariff refusal did the same, and they reach an operator through `self.arb.explain()`. This is exactly the point<->hour conflation TARIFF-14 removed from `at()`, left standing in the prose. `price_forecast.py`'s §8.3 carry-forward log line carried the third instance - a carried-HOUR count over a POINT count - and DOCS quotes it verbatim, so it is corrected here too. 3. The plan reached no HTTP surface at all. `rows["Tariff"]` was `static_status()`'s 30 s-tick sentence and never saw the provider plan - it read 'no static profile' at all 802 soak samples on a site whose feed was answering. It now carries the plan's shape. ⚠️ The two sources are kept distinguishable: the plan half is stamped with its own age, measured from `tariff_at`, because it can be up to TARIFF_MAX_AGE_S (5400 s) old. FCST-04 pins that row to DOCS as a pair; DOCS moves in this commit. 4. `main.py`'s "if and only if" was false. `cycle()` returns at the input hold before `self.arb = None`, so an armed site read `off (arbitrage_enabled)` - naming an option that is on - and, after one completed cycle, showed a decision up to 15 s stale as a current one. The row now reads the OPTION and separates three facts; `cycle_at` and `arb_at` make "this cycle reached no decision" an observation. THE DELIVERABLE IS THE CHECK. All four survived 29 green suites because nothing graded the strings a human is shown. `test_price.py` section 12 renders through the shipped `status_payload()`, parses each number out of its OWN SLOT and compares it against a figure computed from the fixture's construction parameters - not from the property the row was built out of (habit 4), and not as a substring of a sentence the same file wrote (habit 14). The fixture set is four plan shapes and the check computes and prints the field pairs no fixture separates. The *Arbitrage* row's states are driven through real cycles with a sensor answering None and graded by INEQUALITY. No behaviour changed: no threshold, refusal rung, claim or setpoint moved. MUTATIONS: 16, no survivors, one at +0 B (the risky delta) and red. Two were found by the battery INSIDE THIS CARD'S OWN CHECK: a -190 B survivor whose fixture varied two things at once (habit 4), and a mutation whose red was a TRACEBACK in an f-string operand and therefore named nothing (FCST-06). Both closed; the table is on the PR. All 29 test files green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
a991438e40 |
TARIFF-13: the coverage figure beside the peak stops resetting at a restart
checks / unit (pull_request) Successful in 7m27s
The capacity-tariff status row printed a peak read from SQLite next to a count
of banked quarters read from PROCESS MEMORY - `PeakTracker.recorded`, an `int`
set to 0 in `__init__` and counted up inside `sync()`. A 40-hour soak caught
what that means at a driven restart, on both instances independently:
before: 2026-09: peak 365 W, set by the quarter at 2026-09-11T18:45:00+00:00
- 10 % of the 3500 W soft limit; 120 quarter(s) banked
after : 2026-09: peak 365 W, set by the quarter at 2026-09-11T18:45:00+00:00
- 10 % of the 3500 W soft limit; 0 quarter(s) banked
Reproduced here before anything changed, through the real Controller and a real
restart - a second Controller object against the same file on disk - at 12 -> 0
with 12 rows standing in `quarter_blocks`.
The peak is durable and was never wrong. The COUNT is what says how much of the
billing month that peak covers, and 365 W over 120 quarters and 365 W over 0
quarters are different claims about the same number. Mid-month, after every
restart, the page made the weaker claim while displaying the stronger one's
value. That is TARIFF-01's own argument - an unreadable store must not read as a
zero peak, because a zero peak is disarming - one column over.
`PeakStore.banked_count(month)` asks the database, and `recorded` is a property
over it. Two more defects in the same variable fell out once it was driven, and
neither was in the ticket: it was never scoped to a MONTH (on 1 October the row
still showed September's tally beside October's empty month - measured), and it
missed the block `restore()` banks from the checkpoint, which never passes
through `sync()`.
⚠️ NOT 0, AND NOT None, WHEN THE STORE WILL NOT ANSWER. `banked_count()` returns
None and the row renders `an unreadable number of quarter(s) banked`.
`f"{None} quarter(s) banked"` was rejected because it reads as the same zero.
`0 quarter(s) banked` stays true and reachable - it is what a month nothing has
been written to says, and the two are asserted to be different text.
⚠️ THE DEDUPE IS NOT REMOVED WITH THE COUNTER. `_seen` still stops `cycle()`'s
once-a-second `sync()` re-banking a block `P1Ingest.blocks` keeps for a day. The
check that graded it asserted `recorded == 1` - the dedupe and the figure
reporting it were the same variable - and now grades `sync()`'s RETURN, because
counting rows cannot see a re-bank at all (PRIMARY KEY no-op).
THE TIE RULE, DECIDED RATHER THAN EMERGENT: at equal wattage the EARLIEST
quarter keeps the attribution. No bill and no guard moves - `peak_w` is still
only ever raised, the `>` term is untouched, SAFETY-07 reads the same watts.
The two readers DID disagree: the upsert's strict `>` kept whichever tied block
was WRITTEN first while `recompute_month()` has always kept the earliest, the
same only while blocks arrive in time order, and measured to diverge (09:45
against 09:00) fed newest-first.
⚠️ AND THE SOAK'S DRIFTING QUARTER WAS NOT A TIE. Six exactly equal 365.0 W
quarters re-attributed zero times on the shipped tree - `>` is strict. What
moved it was a real new maximum BELOW THE ROW'S OWN RESOLUTION: the row renders
whole watts, so 365.0000001 W is a new peak to the database and the same 365 W
to the reader. Left alone deliberately, and pinned so it is not re-diagnosed.
test_tariff.py parts 11 and 12. 12 mutations, all red, listed on the PR; M2 -
`banked_count()`'s sqlite3.Error arm returning 0 - was a SURVIVOR at -3 B on the
first battery, because a handle that never opened short-circuits before any SQL
runs and nothing reached the except arm. Closed with an open store whose table
is dropped under it, with a precondition that the same call answered 4 first.
main.py is NOT touched - TARIFF-11 holds its status rows. The row picks this up
without editing because `recorded` is an attribute access and is now a property.
The residual is stated in DECISIONS §3: `recorded` answers for now() while the
peak follows `checks(when=...)`, and the shipped install has exactly one call
site - `self.checks()` with no argument, main.py:4359 - where they are the same
month, so the live page is correct and durable. `recorded_in(when)` is shipped
and the row's move onto it is one token, for whoever holds main.py next; part 10
pins the present behaviour against a row count taken from `quarter_blocks` so
the gap cannot be quietly forgotten.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
ac9854886b |
TARIFF-15: your own tariff card, as two coefficients the card itself grades
checks / unit (pull_request) Successful in 7m14s
A Belgian dynamic contract prices energy as `B x index + A`, and the two
coefficients exist on exactly one artefact: the customer's own tariff card.
There is no machine-readable source for them anywhere - CREG's consumer
tariff-card pages 404, CREG Scan is a JS wizard, the annual report has the
supplier list without per-product coefficients, VREG was unreachable, and
every coefficient found in research came off a supplier's own PDF, one
image-only. So nothing can be scraped and a per-supplier plugin would have no
source for its numbers, which is why TARIFF-07 withdrew three of them. The
customer is the only party who can see their own coefficients; they type them.
New provider `custom_formula`, one new option `price_formula` (a JSON string,
the `static_profile` precedent exactly), and a new module
`app/custom_formula.py`. The index path is `generic_dayahead`'s, not a second
one: the URL/override decision is now one shared `dayahead_feed_url()` both
plugins call, same feed, same Brussels-calendar range, same columnar parser,
same declared egress hosts.
It declares {ENERGY, MARKUP}, NOT ALL_IN. A card's Tariefformule line is the
energy component alone - Eneco tabulates network tariffs and levies
separately, ENGIE states the formula excludes network, distribution,
transport, levies and excise - so ALL_IN would lie for every operator who
typed what their card says and would drop the taxes from every hour
(0.2125 -> 0.1555 EUR/kWh, measured).
THE CARD IS THE GRADER, and that is why this is safe to ship. The framework
already mechanises that a PLUGIN cannot double-count. This introduces a risk
none of those guards can see because it is config, not code: the OPERATOR
double-counting, by folding network charges into `offset` while
price_taxes_eur_kwh carries them too. So validate.py recomputes the card's own
printed price from the operator's coefficients at startup and refuses to start
unless the two agree to within 0.01, naming the discrepancy. An inflated
offset cannot pass: 15.55 becomes 28.27. The same check catches VAT omitted,
VAT doubled, a transposed digit and a unit mismatch between the two sides.
And the limit, in the same sentence as the claim: it grades the coefficients
against the card, NOT the card against reality. A consistent-but-wrong pair
passes. A second refusal covers the one unit error the first cannot see - the
one applied to both sides at once - by bounding the card's own point to
0.02-1.00 EUR/kWh. Its FLOOR is applied to the energy figure rather than the
all-in one because the shipped 0.06 of taxes is three times that floor and
would carry a hundredfold error over it alone; found by writing the mutation,
not by review (M10, +0 B).
The market's own arithmetic, reproduced through the shipped code:
Eneco (0.102 x 133.9905 + 1) x 1.06 = 15.5471 card prints 15,55
ENGIE (0.1 x 61.96 + 0.9) x 1.06 = 7.5218 card prints 7,522
NO EXPRESSION EVALUATION OF ANY KIND. The string is settable over HTTP through
the add-on's own ingress page, so eval on it is RCE in a root container
holding SUPERVISOR_TOKEN and driving an inverter over RS485 - but the deciding
argument is that an expression is UNVERIFIABLE: two coefficients can be graded
against the card, an arbitrary expression cannot be graded against anything,
so it would make the invisible-wrong-coefficient problem strictly worse. An
unknown field is REFUSED rather than ignored, so `"expr"` is told it does not
exist. Future shapes become named fields, never a grammar. test_price.py 15f
walks the module's AST for eval/exec/compile/__import__/literal_eval and
exercises the scanner's red direction on every run.
Refused at startup: card absent or out by >0.01; `units` absent (no default);
factor == 0 (every spread 0, arbitrage silently never fires - the message
points at static_profile); factor < 0 (inverts the market); vat_pct outside
0-30 (0 stays legitimate); non-finite or non-numeric; unknown field, index or
resolution; the plausibility band. A card older than ~6 months WARNS and does
not refuse - ENGIE freezes coefficients for a contract's duration. Negative
output prices are not refused anywhere.
A startup preview logs the next 24 h as `index EUR/MWh -> all-in EUR/kWh` with
min/median/max and the day's spread, through a new default-silent
`PriceProvider.startup_preview()` hook - only the plugin knows what went in to
its own arithmetic. Emitted once per process, and a preview that raises cannot
cost the site its prices.
`custom_formula` joins the config.yaml enum through the DERIVED set
PROVIDERS | RETIRED_PROVIDERS | {"off"}, not a hardcoded list. Both
translations describe the option and the new id. DOCS.md replaces the
"planned" sentence with the shape, a worked example from a real card, a real
startup transcript and the limit of the check stated beside the claim.
22 mutations, one per check added, no survivors - MUTATION.md carries the
ledger. M13 (the preview's index column) was a -13 B survivor of the whole
suite on the first attempt because the check graded the HEADING and not the
row; it is graded on a rendered row now. All 29 suites green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
f620f7cf80 |
TARIFF-07: three plugins that never fetched a price are withdrawn, and a site configured on one is told so
checks / unit (pull_request) Successful in 7m12s
engie_dynamic, totalenergies_dynamic and eneco_eddy are removed from PROVIDERS and from every surface that listed them. They did not stop working - they never worked. Re-verified by hand on 2026-09-13 before deleting anything: 404 with Kong's "no Route matched with those values"; a TLS handshake that fails because api.totalenergies.be is absent from the certificate's SAN list; 404 with an empty body. All three are also structurally impossible - the coefficients are per-contract and behind a customer login, there is no regulator index, and "Eddy" is not an Eneco product at all. ⚠️ BACKWARD-INCOMPATIBLE. A config legal on the current version is refused on the next. That is the point of the change: §11.4 turned every failed fetch into a silent fall back, so a site on one of these ids has been running on static_profile - or on nothing - since the day it was set, with nothing on its status page ever differing from a working provider that never found a cheap hour. validate.py now refuses a retired id with a message naming the id, the endpoint, what that endpoint answers, which tariff has really been in force, and what to set instead. No version number is picked here; that depends on a fact about the live box. ⚠️ config.yaml's price_provider enum deliberately KEEPS all three ids. The Supervisor validates the options file against that enum before the add-on starts, so removing them would make an existing config schema-invalid and the refusal above would never be reached on exactly the sites that need it. PROVIDERS is two; the enum stays six; test_price.py asserts the schema offers exactly PROVIDERS | RETIRED_PROVIDERS | {"off"}, derived rather than typed, and register() refuses to re-register a retired id. PriceProduct.REALTIME, _WIDE, Uncertainty.REALTIME_PRODUCT and WIDEN_FACTOR's 2.5 are KEPT with no shipped declarer - it is the AC2 seam, and a reviewer finding a mechanism with zero callers would reasonably delete it. Recorded in DECISIONS/TARIFF-07-withdrawing-three-plugins.md and pinned by a check. False claims corrected: every "Belgian imbalance product" claim about eneco_eddy (DOCS.md, price_forecast.py, price_history.py, static_tariff.py, FCST-04, CHANGELOG - the two released entries annotated in place rather than rewritten); the quarter-hourly examples now cite Belgian day-ahead, which really does settle per quarter since the 15-minute MTU; and export_price_eur_kwh's "no shipped supplier publishes a dynamic injection curve", which is false - Eneco publishes 0,1 x BELPEX-H - 1,188 and ENGIE (B x eSpot_15) - A, same two-coefficient shape with its own coefficients and its own VAT treatment, so the scalar is a simplification and not the market. DOCS.md's provider table is two rows and now says honestly what a Belgian dynamic customer should do today, including that generic_dayahead cannot express B x spot + A and that price_markup_eur_kwh: float(0,1) could not hold a negative offset. The formula provider is referenced as planned, not built. _points_from_json() went with the plugins it served: it read a shape no feed anybody here has ever reached publishes. The one place it survives is a negative stimulus, named row_shape_body(). Nine mutations driven, all red; table in the decision record. 29/29 suites green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
028c3e53fb |
Merge release/1.0 (TARIFF-12) into TARIFF-14
checks / unit (pull_request) Successful in 7m13s
Second base move while this card was open: |
||
|
|
435e1b6f7c |
Merge release/1.0 (TARIFF-10) into TARIFF-14
checks / unit (pull_request) Successful in 7m10s
CI on PR #80 was NOT a test failure. The workflow's "grade the merge, not the branch" step refused the PR because it does not apply, and said so itself: "REFUSED: refs/pull/80/head does not merge into release/1.0. NOTHING HAS BEEN TESTED. This is not a test failure - no test ran." Conflicts were CHANGELOG.md and test_price.py; app/price.py auto-merged. CONFLICTS RESOLVED * CHANGELOG.md - both entries belong under ## Unreleased. TARIFF-10's table row and section come first because it landed first. No version number is picked here; PKG-06/07's note stands untouched. * test_price.py - BOTH cards appended a section "13". Nothing is dropped: TARIFF-10's stays 13, this card's is renumbered 14, and TARIFF-10's temp-directory teardown stays at the end of the file. The two share no fixture, option dict or helper name. WHAT TARIFF-10 CHANGES FOR THIS CARD - nothing in the reasoning, and the check is recorded rather than asserted (decision note §7). In app/price.py the two do not meet: TARIFF-10 added provider_id() and provider_configured() beside price_option() and routed load_prices() through them - the option-reading layer, touching nothing in _Series, at(), covers(), window() or _cover_table(). The merged at() is byte-identical to the one the mutations were driven against. Behaviourally TARIFF-10 makes run_tariff_refresh() run with arbitrage OFF, so a provider-configured site now has a standing plan - and therefore a _Series - where before it had none. It does NOT add an at() consumer to the 30 s tick: static_status() builds a STATIC plan (hourly, immune), main.py calls only plan.words on the fetched plan, and price_forecast.price_permits()/begin_phase() have no caller in main.py at all. So TARIFF-10 neither creates nor closes any exposure this card is about - it enlarges the defect's reach the moment such a site arms trading, which strengthens the fix without changing it. RE-GRADED ON THE MERGED TREE, not carried over * all 29 test files green; * all EIGHT mutations re-driven, purged before each run, each reverted with the fingerprint re-checked. Same verdicts and same red-check counts as before the merge: M1 (the shipped one-hour scan, +68 B) red on 24 named checks across both files; M3 (the ZERO-BYTE tail rule) red on 4; M2/M4/M6 on 1 each, M5 on 2, M7 on 16, M8 on 14. * Clean app/price.py on the merged tree: 90d8ca31f7c0109d, 85953 B. * None of TARIFF-10's 650 new lines of checks moves under any of the eight - they grade resolve_tariff()'s reachability from a configuration, not the lookup. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
f5ea39784d |
Merge release/1.0 (TARIFF-10) into TARIFF-12
checks / unit (pull_request) Successful in 7m16s
CHANGELOG.md was the only conflict: both entries belong under the same
`## Unreleased` heading, TARIFF-10's first because it merged first. No
version number picked.
app/main.py auto-merged, and was re-read because of it. TARIFF-10 changed
WHICH installs run `run_tariff_refresh()` (`arbitrage.enabled(opts)` ->
`tariff_refresh_wanted(opts)`); this card changed what that task does on
a failed fetch. Nothing in the keep/replace reasoning changed, and the
two newly reachable configurations are now DRIVEN in test_arbitrage.py
8b rather than reasoned about:
* a provider configured with trading DISARMED is the case the guard
was designed for, and needs no second fixture because nothing on
this path reads `arbitrage_enabled` at all - asserted over the AST's
symbols and non-docstring constants, after two drafts of that check
went red on a CORRECT tree for matching the word "arbitrage" in a
docstring and in a log line;
* `price_provider: off` + a `static_profile` resolves to the
CONFIGURED product (`origin: "static"`), so `standing.from_feed` is
false on every refresh and the guard never latches - driven twice in
a row, because a guard that latched there would freeze a static
site's plan at its first window for the life of the install.
Also: the kept-plan log line said "arbitrage stops with it", which after
TARIFF-10 is false on a site that fetches without trading; it now says
"arbitrage, where it is armed, stops with it". The keep decision is
strictly downstream of `resolve_tariff()`, so the §8.3 carry into
price_history - TARIFF-10's whole point - is unaffected either way.
All 29 suites green on the merged tree, including TARIFF-10's new
test_price.py section 13. All eleven mutations RE-DRIVEN on the merged
tree rather than carried over: eleven red, no survivors, every revert
fingerprinted. M11 is new - making the guard conditional on
`arbitrage.enabled(self.o)` (+86 B) is red on five named checks.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
7f2c4e20e1 |
TARIFF-14: the point whose own interval covers the instant
checks / unit (pull_request) Failing after 2s
`_Series.at()` asked `s <= u < s + 1 h` of every point IN LIST ORDER and
returned the FIRST match. On the hourly shape every fixture in this
repository carried before TARIFF-08 that is right by accident. Belgium
moved to a 15-minute MTU on 2025-10-01 and the live day-ahead feed
returns 96 points at 900 s, where it is wrong twice over - measured
against the shipped code at
|
||
|
|
c81289527f |
TARIFF-12: a returned degradation is not a refresh
checks / unit (pull_request) Successful in 7m12s
`run_tariff_refresh()` promised in its own docstring that "a failure does not clear the plan", and enforced it with `except Exception` - a branch a supplier outage never reaches. `load_prices()` states the reason in its own words: it "RETURNS, NEVER RAISES, for every failure a site can actually have", because a degradation arriving as a traceback into the planning tick would stop the controller regulating over an expired certificate. So a dead feed RETURNS a §11.4 plan, the `try` succeeds, and the assignment below it overwrote the good plan unconditionally. With `static_profile` unset - the shipped default, and the normal state of a dynamic-tariff site - `_degrade()` returns `TariffPlan(no_data, None, "none")`: a complete 48-hour plan replaced by nothing, at the FIRST failed fetch, ~27 minutes after the last good one. `TARIFF_MAX_AGE_S` (5400 s) never governed anything and there was no serve-stale window at all. Fourth card in one family: FCST-04's M4 (`not ok` only), FCST-05's HIGH (`(JSONDecodeError, OSError)` only), FCST-06 (`not self.ok` only), and now `except Exception` only, for a path that never raises. The question is now asked once, after the attempt, from the evidence that exists - FCST-06's answer, one module over. The evidence is `TariffPlan.from_feed` (did this resolution observe the configured feed) and the shipped `fresh_tariff_plan()`, reused rather than transcribed. A degradation replaces a standing observation only once that observation has aged out, so `TARIFF_MAX_AGE_S` is now the serve-stale window it reads like. A §11.4 static fallback does not replace a fresh provider plan either, although it carries real prices: every point `_degrade()` builds is `provisional=True`, so `firm_points()` is empty, `arbitrage()` refuses and `cheap_now()` is False - everything a consumer may act on is already off - while a day-ahead price for a given hour does not change once published. The rule is deliberately not symmetrical: a standing plan that is itself a degradation IS replaced, or an outage would freeze the operator's static profile at the window it was first generated for. `tariff_at` does not move on a kept plan. It is the moment of the fetch that produced the plan standing, `fresh_tariff_plan()` judges the age from it, and an unmoved timestamp is the only thing that tells a kept plan from a freshly fetched one. test_arbitrage.py section 8b drives the whole chain with nothing stubbed but the socket: the transport raises the way aiohttp does, load_prices() returns no_data, _degrade() builds the §11.4 plan, and the shipped run_tariff_refresh() decides. A check that patched resolve_tariff to RAISE would have passed against the defect. Ten mutations, ten reds, no survivors; 29/29 suites green. Out of scope and unchanged: the persisted price store still does not back the plan during an outage (FCST-03), and the status banner and the Arbitrage row's lag are separately carded. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
e6c45a61e7 |
TARIFF-10: configuring a price provider is what fetches prices
checks / unit (pull_request) Successful in 7m19s
amain() started the background tariff refresh only when arbitrage_enabled was
on, and that option ships false. run_tariff_refresh is the only caller of
resolve_tariff(), which is the only caller of price_history.carry() - so on a
shipped install with a price provider configured nothing was ever fetched: no
plan resolved, /data/price_history.json never created, the Price history status
row reading `empty` for the life of the install, and TARIFF-09's short-horizon
warning unable to fire because there was no fetch to warn about. Measured over
a 40 h two-instance soak on one feed: 0 requests and `present: false` across all
802 samples, against a resolved 132-point plan on the instance with arbitrage
armed.
git log -S puts the refresh task, its arbitrage.enabled() guard AND the DOCS.md
sentence saying a configured provider still fetches in the same commit - OPT-04,
bdd7f18; config.yaml has carried the claim since TARIFF-02,
|
||
|
|
17b7b447c4 |
TARIFF-09: ask the day-ahead feed for the horizon it was handed
checks / unit (pull_request) Successful in 7m10s
`generic_dayahead.fetch()` accepted `since` and `until` and requested the
bare `?bzn=BE`, which answers ONE Brussels day. Everything past today was
then filled from yesterday's profile by FCST-04, flagged provisional, and
§8.3 drops provisional hours from the trade set -- so the optimiser never
saw tomorrow as firm, at any hour of any day, and nothing reported it.
Measured on
|
||
|
|
7a5281e97f |
Merge release/1.0 (FCST-06) into TARIFF-08
checks / unit (pull_request) Successful in 7m10s
One conflict, in CHANGELOG.md's `## Unreleased` block, exactly as expected from two branches landing beside each other: both `_this branch_` table rows and both sections are kept, FCST-06's first. Nothing else conflicted - FCST-06's `test_price_history.py` section 5d and this branch's columnar `feed_body()` merged cleanly - and all 29 test files are green on the result. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
6eba18968c |
TARIFF-08: the day-ahead feed is read in the shape it actually publishes
checks / unit (pull_request) Failing after 3s
`generic_dayahead` could not read one byte of `api.energy-charts.info`, and
never had been able to. `_points_from_json()` asks for `doc["data"]`, a list of
`{start, price_eur_mwh}` objects; that document does not exist. Fetched live on
2026-09-10 the feed returns COLUMNAR parallel arrays and no `data` key at all -
`unix_seconds` (96 UTC epoch seconds, 900 s apart), `price` (96 floats),
`unit: 'EUR / MWh'`. Driving the shipped parser against that body:
`SourceUnavailable: the feed carried no 'data' list`. It is the only shipped
provider whose endpoint anybody has reached, so dynamic pricing did not work.
AND §11.4 MADE IT SILENT, which is why it survived to release: a parse error
becomes no_data, becomes the static profile, becomes arbitrage off - the
CORRECT degradation, saying nothing about the cause. A site would have sat on
the fallback indefinitely.
AND THE SUITE COULD NOT SEE IT, because every fixture was built from the
parser's own assumption. test_price.py, test_price_history.py and
test_static_tariff.py each built `json.dumps({"data": [...]})`, a shape invented
here and published by nobody, so the checks graded the parser against the
parser's guess - a closed loop no coverage inside it could ever have escaped.
MUTATION.md habit 19 records it as the fourteenth instance of habit 4 and the
first where the fixture and the code under test shared a SHAPE, not a number.
WHAT CHANGED
* `_points_from_columnar_json()` - a SECOND function, not a sniff. A parser that
decides which document it received is one that can decide wrong, and a
wrong-but-parseable response then becomes a price. Feeding the row shape to
`generic_dayahead` is now a graded no_data.
* Unequal arrays are refused in both directions, with the two lengths in the
reason. `zip()` stops at the shorter list silently, and a truncated `price`
array would have produced a real series missing the evening peak - traded on
as complete, where no data at all switches arbitrage off.
* A unit that is not EUR/MWh is refused. The plugin converts with a fixed
0.001, and `MAX_PLAUSIBLE_EUR_KWH` only bounds prices that are too LARGE.
* `unix_seconds` are read as UTC instants explicitly; §9.3's Brussels rendering
stays in `assemble()` rather than being copied into the plugin, where a
mutation could not tell it from a no-op (M4 proved exactly that on a first
draft, and the line was removed rather than fenced).
* A published null is dropped and logged with a count; an all-null body is
no_data named by this parser rather than by the boundary validator.
FIXTURES
Two unmodified response bodies under `scenarios/`, captured by hand on
2026-09-10: quarter-hourly (2026-09-10, 96 points at 900 s) and hourly
(2025-09-10, 24 at 3600 s - the same endpoint before Belgium's 15-minute MTU).
`energy-charts-be-price-captures.json` records the URL, retrieval time, unit,
licence-as-returned and a sha256 of each, and the replay RE-DERIVES the
checksums, so a fixture edited to make a check pass stops being a capture. Data
CC BY 4.0, Bundesnetzagentur | SMARD.de, via Energy-Charts (Fraunhofer ISE),
published without changes - the same BE-zone licence check DATA-02 established.
The surviving invented fixtures are renamed `synthetic_row_feed` at every call
site. `engie_dynamic`, `totalenergies_dynamic` and `eneco_eddy` are untouched
and have no capture: their URLs are unverified and withdrawing them is
TARIFF-07's open decision. Nothing should read their green checks as evidence
that those feeds parse.
MUTATIONS - 12, all red, no survivors. Purged tree, mounted `:ro`, `python3 -B`
(TEST-15). M1 drop the equal-length refusal; M2 make it one-sided; M3 drop the
unit check; M4 `assemble()` stops rendering at the Brussels offset; M5 read
`unix_seconds` as a naive local clock; M6 zero-fill a null instead of dropping
it; M7 drop the all-null refusal; M8 sniff for the row shape; M9 drop the
deprecated warning; M10 drop the dropped-nulls warning; M11 edit one price in
the committed capture; M12 point `generic_dayahead` back at the row parser -
red across all three price suites.
END TO END, LIVE, 2026-09-10: `resolve_tariff()` returns a `TariffPlan`,
`origin='provider'`, 96 quarter-hourly points, spacing [900] s, no decimation,
first point 2026-09-10T00:00:00+02:00 at 0.30608 EUR/kWh all-in. FCST-04's H1
fix was never theoretical. All 29 test files green.
STILL OPEN: `generic_dayahead` asks for no date range, so the default URL
returns one published day - a full 48 h horizon is reached only through §8.3's
carry-forward fill.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
c45893ffad |
FCST-06: "cannot persist" becomes one question, asked once, about the outcome
checks / unit (pull_request) Successful in 7m14s
price_history.py's docstring states its rule unconditionally - "A store that
cannot persist now records nothing, and both of its answers say the same
thing" - and FCST-04 enforced it against `not self.ok` only, which is one
SYMPTOM: the durable volume is missing. `ok` is about the DIRECTORY, and a
read-only remount and a full disk both leave it True. Reproduced on
|
||
|
|
375a1e29d2 |
FCST-05: one byte stops stopping the add-on, and the write path gets the read path's standard
checks / unit (pull_request) Successful in 7m10s
HIGH - a non-UTF-8 byte in /data/price_history.json stopped the add-on
from starting. `_load()` caught `(json.JSONDecodeError, OSError)`.
`UnicodeDecodeError` is `ValueError -> UnicodeError -> UnicodeDecodeError`:
neither of those, and `issubclass(UnicodeDecodeError, OSError)` is False. So
it escaped `_load()` -> `_open()` -> `PriceHistory.__init__`, which
`Controller.__init__` does not guard - breaking `_load()`'s own stated
contract, "a corrupt cache must not stop the controller". The handler now
names the ValueError FAMILY (the file's content) beside OSError (its bytes),
because a third subclass nobody has thought of is how this arrived the first
time. The suite could not see it: its "unreadable file" fixture writes
"{ this is not json", which is valid UTF-8 and fails one step later, in
`json`. A fixture holding a genuinely undecodable byte is now beside it,
with the difference between the two asserted as a precondition.
MEDIUM - a malformed `start` under the day the feed is writing to killed the
tariff plan permanently. `_remember()` merged with `{q["start"]: q ...}` and
sorted on `q["start"]`, trusting a value read off /data to be a hashable,
sortable string. An int, null, a dict or a list raised TypeError out of
`carry()` -> `resolve_tariff()` -> `run_tariff_refresh`, which catches
Exception - so the add-on stayed UP while every refresh raised forever, the
plan retiring after TARIFF_MAX_AGE_S with arbitrage and the cheap window off
for good, and no self-heal because `_remember()` raised before `_save()`.
The read path was properly defensive throughout, which is why `yesterday()`
survived and the existing fixture passed - it files its malformed rows under
a day the feed is NOT writing to. Both paths now share one validator,
`_point_of()`. A row that is not a point is dropped, reported, and written
back out clean.
...and the status row said the store was healthy while the plan was dead:
`words` read '2026-01-15 (1 h)'. `_load()` now counts the rows inside a kept
record as well as the record itself, so the store stops reporting plain
health from the moment it is opened; the note names what was FOUND at open
and what was DROPPED by the refresh, and clears once the file is rewritten.
...and the merge key is the validated INSTANT rather than its spelling,
which is what rule 4 already said. The lexicographic sort beside the string
key also put the second 02:00 of the 25-hour October day (+01:00) before the
first (+02:00); stored order only, since `_parse_points()` re-sorts.
LOW - the status row counted POINTS and printed them under the HOUR's name:
'2026-01-13 (96 h)' for a 24-hour day on the quarter-hourly feed this add-on
already supports. It is now '96 points over 24 h' - two facts, each under
its own unit.
LOW - two stated reasons were false. `_audit`'s "WHY IT IS STRICTER" claimed
the rework refused the same published point emitted twice and a carried
point sharing a published hour, "which the old count never looked at". A
differential over the whole domain the audit can express finds ZERO
divergence in both directions: the old `seen` count already refused the
first (one point twice is one hour twice) and the old IDENTITY rule already
refused the second. The reworked audit is EQUAL to FCST-03's, not stronger;
the only behavioural change is the intended relaxation, and it stays. The
differential is committed as a check rather than left as prose.
...and the audit's real limit is named: it does not check COMPLETENESS. Fed
the decimation defect FCST-04 was raised for it ACCEPTS, and it accepts an
empty output. So `_audit` is not what stops that recurring - the count and
identity checks are, and the text now points at them. Not made complete:
`published` is the whole read while the fill emits only [since, until), so
the rule as stated is wrong, and building it takes the 1/12/48 h horizon
checks red on a healthy feed. Measured, not assumed.
12 mutations, purged tree, every one RED, no survivors. All 29 test files
green. Nothing deployed; no option added; config.yaml untouched.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
b59f5ce31b |
FCST-04: the carry-forward stops decimating a quarter-hourly feed, and a broken cache stops stopping the add-on
checks / unit (pull_request) Successful in 7m22s
Rework of the FCST-04 branch against review. Every finding below was proven by a runnable script before it was touched and re-run after; every check added or repaired was driven red by a mutation, `__pycache__` purged first (MUTATION.md, TEST-15). 29/29 test files green. ⚠️ H1 - A SUB-HOURLY FEED WAS DECIMATED TO ONE POINT AN HOUR, AND THE SPREAD WENT WITH IT. `fill_from_yesterday()` keyed the published set as `{_utc_hour(p.start): p for p in r.points}` - LAST POINT OF THE HOUR WINS, the other three dropped. `eneco_eddy` is the Belgian imbalance product and settles per QUARTER, and `_validate_raw()` accepts any strictly-increasing spacing, so this is a shape the product supports today. Measured on a 96-point quarter-hourly feed - ALL FIRM, FULLY PUBLISHED, nothing to carry: the plan reached the optimiser as 15 points, the arbitrage spread fell from 0.143 to 0.014 EUR/kWh, and the cheapest "hour" became a `:45` point whose `at()` window runs into the next one. Not the windowing effect this card is about; a feed losing 84 % of its own prints, with no flag anywhere reporting it. The fill now decides only WHICH WHOLE HOURS NEED CARRYING: every published point inside the window passes through BY IDENTITY, and a carried point is added only for a whole hour with no published coverage at all. Same feed, same fixture: 60 of 60 firm points kept, spread 0.134 over the hours still ahead. ⚠️ AND `_audit()` GOT STRICTER, NOT LOOSER - that was the condition on doing it at all. The old post-condition refused any repeated `_utc_hour`, a count that cannot express four points in one hour. Two rules replace it and SUBSUME it: a published point must BE one of that hour's published points by identity and may be emitted only once; a carried point may stand only in an hour absent from the published set, must be flagged True, and may not repeat. So the duplicated carried hour it existed to catch still raises, the same published point emitted twice now raises, and a carried point sharing an hour with a real print now raises too - which the count never looked at. Three mutations, three reds. ⚠️ H2 - A DAY RECORD THAT WAS NOT A RECORD STOPPED THE ADD-ON FROM STARTING. `_load()` validated `version` and that `days` is a dict, never that each VALUE is one. `{"version": 1, "days": {"2026-01-14": "oops"}}` loaded as ok=True, last_error=None, and then `rec.get(...)` raised AttributeError out of `words`, `yesterday()` and `resolve_tariff()` alike. `PriceHistory(...)` and `.words` are both unguarded in `Controller.__init__`, so the controller did not come up - and it never self-healed, because `_remember()` raised on the same record before it could reach `_save()`. That falsifies the CHANGELOG's "A BROKEN CACHE IS NOT A BROKEN CONTROLLER" in the one direction that matters. The asymmetry that produced it is visible in the file: `_parse_points()` is carefully defensive about every field of a POINT and `_load()` was not defensive about the record holding them. Unusable records are now dropped and REPORTED (`words` says how many and why), and `words` is total by construction as a second line. M3 - `yesterday()` WAS OFF BY ONE DAY FOR 00:00-00:59 AFTER SPRING-FORWARD. `brussels()` renders at the FIXED offset for that instant, so `brussels(stamp) - timedelta(days=1)` subtracts 24 ABSOLUTE hours - and the Brussels day before the March transition is 23 hours long. At 2026-03-30T00:30+02:00 it returned 2026-03-28's prices as "yesterday", or `no_data` naming a date that is not yesterday. The arithmetic is now on the local DATE, which has no offset to lose, and both transitions have a check - the module's headline claim had none. M4 - WITH NO /data THE STORE STILL FILLED, IN MEMORY. `_save()` short-circuited on `not ok` while `_remember()` populated `self._days` anyway: `words` said "unavailable" and `yesterday()` answered A SERIES that is gone on the next restart. The module docstring rejects exactly that ("a yesterday that silently forgets") as its reason for not calling makedirs, so the code now matches the docstring rather than contradicting it. M5 - THE PRUNE MUTATION SURVIVED BECAUSE THE STIMULUS WAS DEGENERATE. §8's clock-jump check seeded ONE day, so `if len(self._days) <= KEEP_DAYS: return` fired and the body it is named after never ran: pruning by arithmetic against the clock - which empties the store on exactly the morning the fill is for - passed the whole 29-file suite. The fixture is now written to a file and reopened (`_load()` does not prune, which is how a store legitimately holds more than the cap) with KEEP_DAYS + 2 days, and the mutant is red. M6 - THE AST ORDERING CHECK COULD NOT CATCH A REVERSAL, AND TWO DOCUMENTS CITED IT AS A GUARANTEE. `_calls.index("_remember") < _calls.index("yesterday")` grades `ast.walk` BFS DEPTH: `self._remember(...)` is a statement and `self.yesterday(...)` is an ARGUMENT of the fill, one level deeper, so `_remember` came out first whichever statement was written first - shipped and reversed both scored True. It is now line numbers AND, the half that matters, the behaviour: a feed carrying yesterday alongside today into an EMPTY store must fill the whole horizon; reversed, the lookup finds nothing and the plan is only the published hours. Reversing the two statements is red on both. L14/L9 - KEEP_DAYS = 3 IS THE STEADY STATE EXACTLY, so a newest-N cap has no slack: a feed publishing to D+2, or ONE stray point in the wrong year - which sorts LAST and can never age out - pushes yesterday out for good. `_prune()` now PINS the two days a lookup can actually ask for on top of the cap. Pinning is additive, so it can only RETAIN and the WITNESS-03 property (nothing is deleted by clock arithmetic) is preserved by construction; `stamp` stops being a dead parameter; the store is bounded at KEEP_DAYS + 2. L8 - the horizon end was not floored while `since` was, so a 48 h request made at any instant off the hour returned 49 points. §1's count was green only because its NOW was exactly :00:00, a shape production never has; the fixture now sits at :17:43. L10 - a failed `_save()` leaked its temp file; at 48 writes a day a persistent write failure leaked 48 inodes a day onto the volume that was already the problem. L15 - `{"version": 1.0}` passed, since `1.0 == 1`. L16 - the `_remember` tree walk scanned `app/*.py` only and matched a bare string; it now parses `app/`, `tools/`, `scenarios/` and `estop/` and looks for the NAME, so a comment does not fail it and a call in `tools/` cannot pass unseen. CLAIM-ACCURACY DEFECTS, WHICH THIS REPO TREATS AS REAL: * L7. DOCS said "*Tariff* on the status page reads `provisional` through the morning". FALSE - `tariff_words` is assigned only from the HA price-entity branch and from `static_status()`, both on the 30 s tick, and the plan's own sentence reaches `_LOG.info`. The doc now says what an operator can see (the Price history row, the Arbitrage row's own refusal sentence, the refresh log line) and a check pins the PAIRING - wiring the plan into the row is fine, correcting the doc is fine, doing one without the other is red. * L11. "fills EVERY unpublished hour" is conditional: a partial yesterday leaves the local hours it never held out of the series (§11.4 for those hours, and `at()` raises rather than answering). Correct behaviour, overclaimed wording, and untested - all three fixed. * L12. DECISIONS §1 leaned on `TariffPlan.cheap_now()`, which has NO PRODUCTION CALLER on the provider plan (`self.cheap` comes from `static_status()`, which builds its own). The conclusion holds on `arbitrage()`'s firm-pair refusal alone, which does reach control; the evidence is now stated at the reach it has. * L13. §1's "passed through by identity" check compared `eur_per_kwh` between two SEPARATE `resolve_tariff()` calls, where `is` could never have held. The value comparison is kept and now says what it grades; identity is graded on a read the file constructs and still holds. * L17. `PriceHistory.words` and the new status row had no check at all - and `words` is one of the two things H2 crashed. Both now have one. * L18. main.py's inline note carried the "widens what the optimiser can SEE, never what it may act on" guarantee without the windowing caveat that the CHANGELOG, DOCS and `resolve_tariff()`'s docstring all carry. It is the one place a maintainer reads it unqualified. EVIDENCE. All eight reviewer proofs re-run: p1/p1b return 29 March, p4 keeps 60 of 60 firm points at spread 0.134, p5 starts and reports, p6 D leaves no temp, p6 E refuses 1.0, p6 F records nothing, p7 returns 48 for 48. p2's script still scores True/True because it re-implements the OLD algorithm - the reversal is now driven as a mutation instead, and is red. p3's script always showed the shipped code correct; what was wrong was the fixture, and its mutant is now red. Twenty mutations driven, no survivors, tree fingerprinted and `__pycache__` purged before each: decimation (2 suites red), audit x3, unfloored `until` (2), unvalidated day records (7 checks), instant-subtraction yesterday, in-memory fill on a volume-less store, clock-arithmetic prune, cap without the pin, leaked temp, loose schema type, empty `words` (5), reversed `carry()` (2), a `_remember` leak in tools/ spelled two ways, a neighbour-filling fallback, a copy instead of identity (2), the DOCS claim in both directions, and the caveat removed from main.py. Baseline and the unmutated tree both green. No option added, config.yaml untouched, and the CHANGELOG entry still picks no version: PKG-07's rule, and only the deployer knows whether 0.9.0's image has been pulled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
0618194d9c |
FCST-04: the carry-forward fill reaches the plan, and the day it carries survives a restart
checks / unit (pull_request) Successful in 7m11s
FCST-03 shipped `fill_from_yesterday()` complete and checked, and shipped the consumers written for it - `TariffPlan.firm_points()`, `cheap_now()`'s refusal of a provisional hour, and `arbitrage()`'s refusal 3, which drops provisional hours from the trade set rather than refusing the whole series. It shipped NO CALLER. Nothing in `app/` named the fill, so no series ever contained a carried point and every one of those consumers was exercising its all-firm branch. ⚠️ THE DEFECT THAT PRODUCED WAS NOT AN ERROR ANYWHERE. `load_prices()` returns what the feed published and nothing widened it to the requested horizon, so on a dynamic site between midnight and the 14-16 h CET publication the plan covered the rest of today and nothing more - measured on the fixture here, 24 h against a 48 h request. `arbitrage()` then took `max - min` over that truncated window and reported a spread. The number was real, the window was half the one configured, and nothing said so: tomorrow evening's peak, the hour a morning charge would be sold into, was not in the series to be compared against anything. A missing hour is not a wrong price - it is an hour the optimiser never learns exists. WHAT THIS ADDS. `app/price_history.py` keeps the PUBLISHED prices of the last KEEP_DAYS Brussels days in /data/price_history.json; `resolve_tariff()` gains a required keyword-only `history` and fills every unpublished hour of the horizon from yesterday's same-wall-clock hour, flagged. Persistence rather than a variable on the refresh task, because the window the fill exists for is midnight -> publication and an add-on restarted at 08:00 would otherwise spend all of it on the truncated series. Not in state.json: the refresh runs every 1800 s and that file holds the maintenance history and SAFETY-02's latch. ⚠️ ONE CHANGE HERE MOVES ENERGY, AND IT IS NOT THE ONE THE CARD IS NAMED FOR. Carried hours are provisional, so §8.3 keeps them out of the trade set: the fill widens what the optimiser can SEE, never what it may DO, and test_price_history.py checks that so it cannot be overclaimed later. What does change a trade is that the filled series is windowed to [since, until), so hours that have ALREADY ELAPSED are no longer in the spread. Before, a cheap night that had gone sat in the series as the day's cheapest hour - and a cycle cannot buy in an hour that is past, so the trade was quietly never taken. Section 2 grades this by finding the cheapest firm hour with and without the fill and showing it MOVES, from 02:00 UTC to 08:00 UTC on the fixture. ⚠️ A DEAD FEED IS STILL §11.4, NOT YESTERDAY. The fill runs only on a `series` read. The two are indistinguishable to the optimiser - both 100 % provisional, so arbitrage refuses on the firm-pair rung and `cheap_now()` is False - so preferring yesterday's feed over the `static_profile` an operator configured FOR that case would change a documented degradation for a difference only the status page can see. That, and two more, in DECISIONS/FCST-04-the-day-that-is-carried.md. ⚠️ THE ANTI-DECAY RULE IS AN ORDERING, NOT A VALIDATION, and saying so is more useful than a guarantee that would not hold. Feeding the filled series back in is how this rots - day 2 carries day 1's guesses, day 3 carries day 2's carry of them, behind a `provisional` flag that stays TRUE while the NUMBER decays. No value-level check can catch it: a carried point and `eneco_eddy`'s published-provisional quarter are the same three fields with the same flag. So `carry()` is the only public entry, it records BEFORE it fills, the filled series exists only as a return value the object never sees again, and test_price_history.py walks app/ for any other module naming `_remember` and reads `carry()`'s AST to pin the order. EVIDENCE. 29/29 test files pass in the CI image. Eight mutations driven against app/price_history.py and app/static_tariff.py, __pycache__ purged before each run per MUTATION.md/TEST-15: newest-record lookup (5 red), recording the filled series (1), replace-instead-of-merge (10), UTC-date keying (10), removing the fill call entirely (12), a lost price field defaulting to 0.0 (2), prune by clock arithmetic (1), a degraded reason that stops naming its cause (1). No survivors; baseline and revert both green. Three of those first crashed the harness instead of reporting a FAIL - "it was refused" and "it broke on the way to being refused" must not grade the same - so `why()` and `_priced()` were added and the run repeated. No option added, config.yaml untouched, and the CHANGELOG entry deliberately picks no version: PKG-07's rule, and only the deployer knows whether 0.9.0's image has been pulled. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
b21e229adf |
SAFETY-43 round 2: the cut-out "positive control" was vacuous, and the record
checks / unit (pull_request) Successful in 6m29s
stated the wrong mechanism ⚠️ REVIEW FINDING, BLOCKING, AND IT IS THE EVIDENCE THAT WAS WRONG RATHER THAN THE BEHAVIOUR. Part 8b's cut-out arm claimed an "identical power trace" to the wedged arm and that "what separates them is `account()`". EVERY PART OF THAT WAS FALSE, and the check survived deleting the gate it named. Measured: cut-out arm, account() live named 0/200, distinct B shares: [0] cut-out arm, account() FORCED None named 0/200, distinct B shares: [0] wedged arm, account() live named 200/200, shares 77/125/133/154 W At its own cut-out the pack's usable energy ABOVE that cut-out is zero, so `weights()` answers 0.0, `_fill()`'s preferred pass gives it nothing, the healthy sibling covers the load alone so the last-resort pass never runs, and its share is 0 W ON ALL 200 CYCLES. A unit with a 0 W share is not in `asked`, so `len(asked) < 2` returns {} BEFORE EITHER ARM IS EVALUATED and `account()` is never consulted. Nothing was identical, "100 % of the ask" was 0/0, and the arm never reached the comparison it was written to grade. WHAT REPLACES IT IS A BETTER FACT, NOT A WEAKER ONE: at its own cut-out OPT-09 STOPS ASKING THE PACK AT ALL, so SAFETY-43's relative arm is never reached. That is a SECOND, INDEPENDENT protection sitting UPSTREAM of `account()` - the allocator declines to ask before the detector has to decline to alarm. So the arm is kept and re-pointed, not deleted: * the 0 W share is now ASSERTED (`_sat_last[1][Bee] == 0`), not inferred from the silence - a control that cannot say WHY it is quiet cannot fail; * the arm runs a SECOND time with `account()` DELETED (`no_account=True`) and must still be silent, which is what proves which mechanism does the work; * the account gate's claim is re-pointed at test_delivery.py part 1, where it is graded on a REAL positive 125 W share. ⚠️ AND IT WAS INVISIBLE FOR ONE REASON WORTH KEEPING: that was the ONLY line in part 8b that did not print its shares. `inverter-b+0` would have been on screen from the first run. Every line in the part prints them now. The derated control's vacuity guard also now asserts ITS OWN unit is asked, rather than re-asserting a different run's 200/200 - which is exactly why the old guard could not see this. ALSO, from the same review: N1 app/delivery.py said 0.05 was "twelve times more sensitive" than 0.85. 0.85/0.05 = 17 and no reading of the pair gives 12. An unsupported number in shipped source; replaced with what was actually measured. N2 M14's recorded count was 4 named checks in test_delivery.py and it is 5 - part 1's pre-existing "a shortfall AT the threshold is not one" also goes red. It under-claimed, so it never inflated the evidence, but a recorded figure that does not reproduce is still one. N3 test_delivery.py part 1 printed the alarm sentence with a bare `delinquent(...)["b"]`, which raises KeyError under M12/M13 and ABORTED THE FILE AT PART 1, leaving parts 2-8 ungraded. The direction is safe (an abort is a red; MUTATION.md's defect fabricates only greens) but the recorded coverage read smaller than the truth. It is a `.get` now, and M12/M13's counts are re-run: 7 and 7 named checks, not 5 and 6. CFG-07: the assessment is unchanged (worse by one control cycle, 35.0 -> 40.0 s, deliberately not fixed here) and now says WHEN it has to close - BEFORE INVERTER B IS COMMISSIONED (~2026-09-12), because the band is unreachable at N=1 and commissioning B is when it first becomes reachable - and that CFG-07 HAS NO DECISION DOCUMENT IN THIS TREE, so whoever takes it writes one first. No behaviour change. `delinquent()`'s two arms, the fraction, `min_w` and the N=1 path are all untouched by this commit. 27/27 suites green. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU |
||
|
|
2271e147c6 |
SAFETY-43: delinquency measured against the ask, not against a flat 500 W
checks / unit (pull_request) Successful in 6m20s
`delivery.delinquent()` named a unit whose `short_by()` gap exceeded an
ABSOLUTE `min_w = Tuning.saturation_w = 500 W`. OPT-09's SoC-aware weights
shrink a low-headroom unit's share, and shrinking the share shrinks the gap, so
a unit standing at +125 W and delivering 0 W - 100 % delinquent - was never
named. Measured end to end on the real loop (test_packshare.py part 8b):
load 1500 W, B wedged at 15 %, equal weights named on 199/200 cycles
load 1500 W, B wedged at 15 %, OPT-09 weights named on 0/200 cycles
⚠️ The suppressed regime is the quiet one: at a load the healthy sibling covers,
the meter is satisfied, `unmet_w` is 0 and no action-log line fires, so this
alarm is the ONLY instrument that would have told the operator.
WHAT CHANGED, in one line:
named if short_by() > min_w OR short_by() > frac * share
⚠️ `min_w` WAS NOT LOWERED. It exists to stop normal saturation being reported
as delinquency, and lowering it trades a missed alarm for a false one on every
unit at once - SAFETY-41's four-attempt regime. This is a SECOND way to be
named, not a looser first one: all seven of test_delivery.py part 1's existing
fixtures answer identically under both rules, and the absolute arm's suppression
window is still exactly 1000 W / 6500 W, still asserted in part 8b.
THE FRACTION IS DERIVED, 0.85. admin/goodwe:sim/delivery_window.py gained a
`--fractions` axis and grades the constant over the SAME 2640 no-fault runs that
produced `delivery_hold_s`'s 35.0 s floor. Worst continuous legitimate episode,
worst of three families, twenty fractions:
frac 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50
worst 90.0 90.0 70.0 70.0 60.0 55.0 55.0 60.0 45.0 45.0 s
frac 0.55 0.60 0.65 0.70 0.75 0.80 *0.85 0.90 0.95 0.99
worst 40.0 40.0 45.0 45.0 45.0 45.0 40.0 40.0 40.0 40.0 s
absolute arm alone: 35.0 s (SAFETY-42 §3.3, reproduced in the same runs)
⚠️ NO CLIFF ANYWHERE: 0.45-0.99 is flat within one control cycle, and it is not
monotone - §3.3's own mechanism (c). ⚠️ "Zero false namings" is NOT achievable
at any fraction and the record says so; what is zero is false ALARMS - 90.0 s
worst against a 185 s hold, so nothing comes within 95 s of notifying anybody.
N=1 control 0.0 s at every fraction in all 2640 one-inverter runs; flapping
0.0 s in all 840.
DRIVEN. Part 8b pinned the SUPPRESSED behaviour and said "if it ever goes red
because the alarm fired, read the card that made it fire". It now grades BOTH
rules on one run - `share_frac=None` is SAFETY-42's rule exactly:
OPT-09 weights, absolute arm alone named on 0/200
OPT-09 weights, the shipped rule named on 200/200
POSITIVE CONTROL. Same fixture, same weights, same 125 W share, one legitimate
fact changed: a pack at its own 10 % cut-out is named on 0/200 (account() still
gates it), and a unit delivering HALF its share is named on 0/200.
N=1 BYTE-IDENTICAL, asserted: `plan()` handed a `weights` mapping that raises on
any read still answers identically at a roster of one, and the same mapping
raises at a roster of two; `delinquent()` answers {} on all 84 single-unit
(share, measured, rule) combinations including 0 of 125 W.
MUTATION, run on fresh :ro trees: M12 (drop the relative arm), M13 (frac -> 1.0)
and M14 (frac -> 0.05) are all red on named checks. The constant cannot move in
either direction unseen.
⚠️ CFG-07 gets ONE CONTROL CYCLE WORSE and is deliberately not fixed here: the
worst legitimate episode goes 35.0 -> 40.0 s, so the schema's `int(30,900)`
false-tripping band widens from [30,35] to [30,40]. CFG-07 should be re-derived
against 40.0 s.
No option value, no schema bound and no default changed. 27/27 suites green.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
57775d4e06 |
TEST-21: delivery_hold_s's floor re-derived, and 30.0 s did not reproduce
No code and no option changes. What changes is a number this repository claimed
about a shipped safety constant.
`delivery_hold_s: 185` shipped resting on "30.0 s, the worst continuous
legitimate episode at the shipped threshold across all 2640 runs", plus a lag
sweep giving 45.0 s and 90.0 s - from a harness `DECISIONS/SAFETY-42` §1
deliberately did NOT commit, because it imports `plantsim` and `frame_check` out
of admin/goodwe. So the floor under a safety constant could not be re-run. That
is PROC-01's shape, with eleven instances in three days.
The harness is committed now, in admin/goodwe as `sim/delivery_window.py`, and
NOT here. `plantsim` and `frame_check` are that repo's; restating them in this
tree is CI-08's coupling, which has broken three times, and the alternative
fate - skipped for want of its imports - is a green that establishes nothing.
There the dependency runs one way: THIS repo's `control`, `arbiter` and the
shipped `delivery.delinquent()` are imported live out of whichever checkout is
under test. Its `--selftest` is now a step in that repo's `checks.yml`, so a
change here that moves `saturation_w`, `max_w`, `delivery_hold_s` or the shape
of `delinquent()` goes red there instead of leaving a stale number here.
cd goodwe/sim && GOODWE_ADDON_REPO=/path/to/goodwe-addon \
python3 -B delivery_window.py --selftest --campaign --blag
⚠️ THE HEADLINE DID NOT REPRODUCE: 35.0 s, not 30.0 s. Recorded as measured. The
harness was not adjusted until it agreed - the one correction made during the
rebuild was made AGAINST the doc's number (§1 records it) and made every figure
LARGER.
WHAT REPRODUCED - and it is the part the compatibility promise rests on:
* the N=1 control arm is 0.0 s at EVERY threshold in EVERY run. §3.2's algebra
measured, not argued.
* the flapping family is 0.0 s everywhere in all 840 runs - the family that
defeated SAFETY-30's site window still cannot touch this check.
* 45.0 s at twice A's lag, to the cycle.
WHAT DID NOT:
* the headline, by one control cycle (30.0 -> 35.0 s); the reversal family by
two (20.0 -> 30.0 s).
* the NON-MONOTONE curve. §3.3 finding 3 read 55.0 s at 250 W against 40.0 s
at 100 W as a property of the reduction. This rebuild's curve is monotone.
The mechanism is real and is still the reason not to read either table as a
sensitivity curve, but it is an ARGUMENT now, not a measurement, and it is
written down as weaker.
* the low-threshold rows, badly (40.0 -> 120.0 s at 100 W). Nothing ships
there, but that gap is the honest measure of how much of the original table
was a property of axes nobody wrote down. §3.3 fixes every axis COUNT and
RANGE and no individual value; the rebuild prints its choices above its own
table so the caveat travels with the number.
* the four-times-slower row moved the OTHER way: 75.0 s, not 90.0 s.
185 s IS NOT CHANGED. It is 5.29x the re-measured worst (the record claimed
6.2x), 2.47x the four-times-slower case, 6.2x the firmware's LINK_STALE_S veto
and 4.9x inside the billing quarter. All four bounds clear and none narrowly,
and the ordering of the argument is unchanged. Moving a shipped safety constant
because a margin went from 6.2x to 5.3x while every bound holds would re-open
SAFETY-41's four-attempt false-trip regime for nothing.
⚠️ ONE CONSEQUENCE AN OPERATOR CAN HIT. At 30.0 s the rig's floor coincided with
the firmware's veto and a reader could not tell which was binding. At 35.0 s the
rig's is strictly the binding one - and it is ABOVE the schema's own
`int(30,900)` minimum. `delivery_hold_s: 30` is therefore below a MEASURED
legitimate episode and would report on ordinary saturation. Both translations
now say so. Raising the schema floor is a change to a shipped option's contract
and is left to its own card rather than smuggled in here.
⚠️ THE B-LAG ROWS ARE RELABELLED THROUGHOUT. Inverter B does not physically
exist (~2026-09-12); `plantsim.INVERTER_B` is A COPIED, `measured=False`. Every
two-inverter figure in this record is two copies of A, and the lag sweep is a
SENSITIVITY STUDY ON A HYPOTHESIS ABOUT B, not a measurement of it. The old
wording - "MEASURED, not felt" - overstated exactly that, and "the RAMP does not
move it at all" was too strong: halving it is worth 0 s at A's lag and +5 s at
twice it.
Touched: DECISIONS/SAFETY-42 §1 and §3.3, app/delivery.py's provenance comment,
config.yaml's `delivery_hold_s` block, both translations, CHANGELOG Unreleased.
26/26 suites pass.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
|
||
|
|
21f22b393a |
UX-04: nothing was hidden, the defaults pin was never built, and CFG-04 was closed by UX-02
checks / unit (pull_request) Successful in 6m20s
UX-01's three unmet acceptance criteria, closed out. It shipped in 0.7.0 and is LIVE, so all three describe the running install. No behaviour, no schema and no default moves here: config.yaml, translations/ and every module under app/ are byte-identical to |