Changelog

Unreleased

⚠️ THIS HAS NO VERSION AND CANNOT REACH AN INSTALL UNTIL IT GETS ONE. PKG-06's and PKG-07's rule: the Supervisor keys the built image by version:, so ha apps update is a silent no-op on an unbumped change. This branch deliberately does not pick the number, because the right one depends on a fact the branch cannot observe - whether 0.9.0's image has already been built and pulled. If it has not, this belongs inside 0.9.0's section before it ships; if it has, it needs 0.10.0. Whoever deploys decides.

this branch FCST-04 - the carry-forward fill reaches the plan, and the day it carries survives a restart
this branch FCST-05 - one byte stops stopping the add-on, and the write path gets the read path's standard
this branch FCST-06 - "cannot persist" stops meaning "has no /data" and starts meaning what it says
this branch TARIFF-08 - the day-ahead feed is read in the shape it actually publishes, and the fixtures stop agreeing with the parser

FCST-06 - the second way to be a store that cannot persist

A price cache that could not write went on answering a yesterday the file did not contain. price_history.py's docstring states its rule unconditionally - "A store that cannot persist now records nothing, and both of its answers say the same thing" - and FCST-04 enforced it against not self.ok, which is one symptom: the durable volume is missing. ok is about the DIRECTORY, and a read-only remount and a full disk both leave it True. Reproduced on 5059e28 against two real volumes - a /data bind-mounted read-only and a full tmpfs:

with a /data that cannot be written
last_error could not write ([Errno 30] Read-only file system)
words 2026-01-14 (24 points over 24 h); 2026-01-15 (24 points over 24 h) [could not write (...)]
yesterday() series, 24 points
on disk {}

words and yesterday() were describing two different stores, and the 24 points were gone on the next restart with nothing saying so - the silently-forgetting cache that rule exists to refuse, reached by the condition it did not name. No shipped path reaches it: /data is the Supervisor's durable volume and this module is its only writer. The defect is that a guarantee the module states about itself did not hold in one condition.

"Cannot persist" is now ONE derived predicate, asked once, about the outcome. It cannot be answered before the attempt - a directory that existed and was writable a moment ago is not a write that completed - so _save() returns whether the file now holds what memory holds: False with no durable volume, False on an OSError from the write, True otherwise. _remember() keeps only what that one answer says was kept, and the not self.ok test in _remember() is gone rather than joined by a second one. FCST-04's M4 and FCST-05's HIGH were the same shape - a rule enforced on the conditions somebody thought of - so a third cause now needs no third branch.

What is undone is the MERGE, not the store. The state restored is the last one that is on disk, so a site whose volume fills at 14:00 goes on answering the yesterday it wrote at 13:30 - that record survives a restart, so answering it is not a promise the store cannot keep. It simply stops adding to it. The snapshot is a copy.deepcopy: a one-level copy shares the day record the merge rebinds points on, and measured with one, a store holding 12 persisted points answered 24 after a failed merge.

⚠️ A failed write is still not fatal, and that was a constraint rather than an oversight. §6 and this module's opening: a broken cache must not be a broken controller. An add-on that will not start because /data filled up is a worse defect than the one being fixed, so _save() reports and returns - the failure stays in the log, in last_error, in words and in yesterday()'s reason - and the shipped resolve_tariff() path still returns a provider plan with no §11.4 degradation. What changed is that it is now acted on.

test_price_history.py section 5d drives it on two real failures with different syscalls and different errnos - a directory where the file goes (os.replace, EISDIR) and a volume that moves out from under an open store (mkstemp, ENOENT) - because the rule is enforced on the outcome and one cause would grade a coincidence. See DECISIONS/FCST-06-cannot-persist-is-one-question.md.

TARIFF-08 - no network price provider had ever parsed a live response

generic_dayahead could not read one byte of api.energy-charts.info, and had never been able to. _points_from_json() asks for doc["data"], a list of {start, price_eur_mwh} objects. That document does not exist. Fetched live on 2026-09-10, the feed returns columnar parallel arrays and no data key at all:

top-level keys: ['deprecated', 'license_info', 'price', 'unit', 'unix_seconds']
  unix_seconds: 96 UTC epoch seconds, first 1788991200, spacing 900 s
  price:        96 floats, first 216.08
  unit:         'EUR / MWh'

Driving the shipped parser against that body: SourceUnavailable: the feed carried no 'data' list. Since generic_dayahead is the only shipped provider whose endpoint anybody has reached, dynamic pricing did not work at all.

⚠️ AND §11.4 MADE THAT SILENT, WHICH IS WHY IT LASTED. A parse error becomes no_data, becomes the static profile, becomes arbitrage off - the correct degradation, and it says nothing whatsoever about the cause. A site would have sat on the fallback indefinitely while the status page reported only that the feed was down.

⚠️ THE SUITE COULD NOT SEE IT BECAUSE EVERY FIXTURE WAS BUILT FROM THE PARSER'S OWN ASSUMPTION. test_price.py, test_price_history.py and test_static_tariff.py each built json.dumps({"data": [{"start": ..., "price_eur_mwh": ...}]}) - a shape invented here, published by nobody. The checks graded the parser against the parser's guess: a closed loop that cannot notice the guess is wrong, and no amount of coverage inside it would have. The loop is broken by bytes nobody in this repository wrote: two unmodified response bodies are committed under scenarios/, one quarter-hourly (2026-09-10, 96 points at 900 s) and one hourly (2025-09-10, 24 points at 3600 s - the same endpoint before Belgium's 15-minute MTU), with URL, retrieval time, licence-as-returned and a sha256 recorded beside them in energy-charts-be-price-captures.json and re-derived by the replay, so a fixture edited to make a check pass stops being a capture. The remaining invented fixtures are renamed synthetic_row_feed at every call site.

The columnar document is read by its own function, _points_from_columnar_json(). Not by teaching the row parser to sniff for both: a parser that decides which document it received is a parser that can decide wrong, and a wrong-but- parseable response then becomes a price. Two shapes, two functions, and each plugin names the one its feed publishes. Feeding the row shape to generic_dayahead is now a graded no_data, so the sniff cannot come back quietly.

⚠️ UNEQUAL ARRAYS ARE REFUSED RATHER THAN ZIPPED. zip() stops at the shorter list and says nothing, so a truncated price array would have produced a real price series with its tail missing - and the tail of a Belgian day is the evening peak. That is worse than no series: no_data switches arbitrage off, whereas a short series is traded on as though complete, and nothing downstream can tell them apart. Refused in both directions, with the two lengths in the reason.

⚠️ A UNIT CHANGE IS REFUSED FOR A REASON _validate_raw() CANNOT COVER. The plugin converts with a fixed 0.001; if the feed ever published EUR/kWh under the same keys, every price would come out a thousand times too small and MAX_PLAUSIBLE_EUR_KWH would not fire, because it only bounds prices that are too large. DATA-02's fetcher already refused on this field; the shipped path does now too.

unix_seconds are UTC instants, said so explicitly (datetime.fromtimestamp(t, timezone.utc)); §9.3's rendering at the Brussels offset stays where it already lived, in assemble(), rather than being copied into the plugin where a mutation could not tell it from a no-op. A published null is dropped and logged with a count - a missing quarter is not a free quarter - while an all-null body is no_data named by this parser rather than by the boundary validator.

End to end against the live feed, 2026-09-10: resolve_tariff() returns a TariffPlan with origin='provider', 96 quarter-hourly points, spacing [900] s and no decimation, first point 2026-09-10T00:00:00+02:00 at 0.30608 EUR/kWh all-in. FCST-04's H1 fix was never theoretical - 900 s is the shape of the real feed.

⚠️ WHAT THIS DOES NOT FIX. engie_dynamic, totalenergies_dynamic and eneco_eddy are untouched: their URLs are unverified, no real body can be captured for them, and withdrawing them is TARIFF-07's open decision. Their fixtures are now named synthetic_row_feed so nothing reads them as evidence that those feeds parse. And generic_dayahead still ignores since/until and asks for no date range, so the default URL returns one published day - a full 48 h horizon is reached only through §8.3's carry-forward fill.

FCST-05 - what FCST-04's own contract still did not hold

A single non-UTF-8 byte in /data/price_history.json stopped the add-on from starting. _load() caught (json.JSONDecodeError, OSError). UnicodeDecodeError is ValueError -> UnicodeError -> UnicodeDecodeError - neither of those, and issubclass(UnicodeDecodeError, OSError) is False - so it escaped _load() -> _open() -> PriceHistory.__init__, which Controller.__init__ does not guard. Reproduced: UnicodeDecodeError: 'utf-8' codec can't decode byte 0xff, and the controller did not come up. That is the same class as the day-record defect the store was reworked for, in the one byte class the rework left uncovered: valid-UTF-8-invalid-JSON, a UTF-8 BOM and a non-dict day record all degraded correctly. The suite could not see it because its "unreadable file" fixture writes "{ this is not json", which is valid UTF-8. The handler now names the ValueError family - the file's CONTENT - beside OSError, the file's BYTES, and a fixture holding a genuinely undecodable byte is in test_price_history.py section 5.

A malformed start under the day the feed is writing to killed the tariff plan permanently. _remember() merged a day's points with {q["start"]: q ...} and sorted on q["start"], trusting a value read off /data to be a hashable, sortable string. An int, null, a dict or a list there raised TypeError; run_tariff_refresh catches Exception, so the add-on stayed up while every refresh raised, forever - the plan retiring after TARIFF_MAX_AGE_S and arbitrage and the cheap window off for good, with no self-heal because _remember() raised before reaching _save(). The read path (_parse_points()) was properly defensive throughout, which is why yesterday() survived and the existing fixture passed: it files its malformed rows under a day the feed is not writing to, so _remember() never opened that record. The two paths now share one validator, _point_of(), and neither has a standard of its own. A row that is not a point is dropped and reported, and _save() rewrites the record clean.

⚠️ AND THE STATUS ROW SAID THE STORE WAS HEALTHY WHILE THE PLAN WAS DEAD. words read '2026-01-15 (1 h)' about the record that was killing every refresh. _load() now counts the rows inside a kept record as well as the record itself, so the store stops reporting plain health from the moment it is opened; the note names what was found at open and what was dropped by the refresh, and clears itself once the file has been rewritten.

⚠️ AND THE ROW COUNTED POINTS AND CALLED THEM HOURS. f"{d} ({_n_points(d)} h)" on the quarter-hourly feed this add-on already supports reads '2026-01-13 (96 h)' for a 24-hour day - the same points/hours conflation the sub-hourly defect above was about, on the row that defect's own card shipped. The cell is now 2026-01-13 (96 points over 24 h): two facts, each under its own unit, and the hour figure is the one that says whether tomorrow morning's fill has a whole day to carry.

⚠️ AND THE MERGE KEY IS THE INSTANT RATHER THAN ITS SPELLING, which is what rule 4 already said. Aware datetimes hash and compare by instant. The string key merged by spelling, and the lexicographic sort beside it put the second 02:00 of the 25-hour October day (+01:00) before the first (+02:00); only the stored order was affected, because _parse_points() re-sorts by instant on the way out.

⚠️ TWO STATED REASONS WERE FALSE, AND THIS REPOSITORY TREATS THAT AS A DEFECT. price_forecast._audit()'s "WHY IT IS STRICTER" section claimed the rework refused two things FCST-03's audit did not. A differential over the whole domain the audit can express - every published mask over 3 hours crossed with every output series of length 0-3 - found zero divergence in both directions: the reworked audit is exactly EQUAL to FCST-03's, not stronger. The old seen count already refused the same published point emitted twice (one point twice is one hour twice), and the old identity rule already refused a carried point sharing a published hour. The only behavioural change is the intended relaxation - several distinct published points in one hour - and that stays. The docstring and the two check texts now say what is true, and the differential is committed as a check in test_price_forecast.py rather than left as prose.

⚠️ AND _audit IS NOT WHAT STOPS THE DECIMATION DEFECT RECURRING. It does not check completeness: fed the decimation directly - four published points in an hour, output emitting only the last - it accepts, and it accepts an empty output. That is a limit, not a regression, and the module docstring said otherwise by presenting the audit as the post-condition guarding provenance. What actually guards it is the point count and the pass-through identity checks in test_price_forecast.py and test_price_history.py, and the text now points at them. It is not made complete: published is the whole read while the fill emits only [since, until), so "every published point appears" is not a true post-condition of those two arguments. Measured - the rule as stated takes the 1 h, 12 h and 48 h horizon checks red on legitimate series.

No option was added, config.yaml is untouched, and nothing was deployed.

FCST-03 shipped the fill and no caller. price_forecast.fill_from_yesterday() was complete and checked, and so were the consumers written for it - TariffPlan.firm_points(), cheap_now()'s refusal of a provisional hour, and arbitrage()'s refusal 3, which drops provisional hours from the trade set rather than refusing the whole series. Nothing in app/ called the fill, so no series ever contained a carried point and every one of those consumers was exercising its all-firm branch.

⚠️ THE DEFECT THAT PRODUCED WAS NOT AN ERROR ANYWHERE. load_prices() returns what the feed published and nothing widened it to the requested horizon, so on a dynamic site between midnight and the 14-16 h CET day-ahead publication the plan covered the rest of today and nothing more - typically 10-24 of the 48 hours price_horizon_h asked for. arbitrage() then took max - min over that truncated window and reported a spread. The number was real, the window was half the one configured, and nothing said so: tomorrow evening's peak, the hour a morning charge would be sold into, was not in the series at all, so the spread it would have created was never compared against anything.

What changes:

  • app/price_history.py (new) keeps the published prices of the last few Brussels days in /data/price_history.json, and resolve_tariff() now fills an unpublished hour of the horizon from yesterday's same-wall-clock hour, flagged provisional. ⚠️ "An" unpublished hour, not "every" one: the fill can carry only an hour yesterday actually published, so a partial yesterday leaves the local hours it never held out of the series - §11.4 for those hours, and asking for one raises rather than answering. Correct behaviour, and the wording is now the behaviour.
  • ⚠️ A sub-hourly feed keeps every print. eneco_eddy is the imbalance product and settles per quarter; the fill walks whole hours to decide what needs carrying, and that is not a rule about what a published hour may contain. Every published point inside the horizon passes through by identity, and a carried point is added only for a whole hour with no published coverage at all. The first draft keyed the published set by hour - last point wins - and a 96-point quarter-hourly feed reached the optimiser as 15 points with its spread down from 0.143 to 0.014 EUR/kWh, on an all-firm, fully-published series.
  • The horizon is whole hours at both ends: since is floored to the hour that contains it, and so is until. Asked for 48 hours at 08:17, the plan is 48 hours long and not 49.
  • resolve_tariff(history=...) is required and keyword-only. A caller with no durable volume passes the explicit NoHistory(). A default of None meaning "skip the fill" would hand a caller who forgot the argument exactly the truncated horizon this card removes, silently.
  • A new status row, Price history, names the days held, how many points each holds and how many whole hours they cover (see FCST-05: it shipped counting points and printing them under the hour's name).

⚠️ ONE CHANGE HERE MOVES ENERGY, AND IT IS NOT THE ONE THE CARD IS NAMED FOR. Carried hours are provisional, so §8.3 keeps them out of the trade set: the fill widens what the optimiser can see, never what it may do. What does change a trade is that the filled series is windowed to [since, until), so hours that have already elapsed are no longer in the spread. Before, a cheap night that had already gone sat in the series as the day's cheapest hour - and a cycle cannot buy in an hour that is past, so the trade was quietly never taken. test_price_history.py section 2 grades this by finding the cheapest firm hour with and without the fill and showing it moves.

⚠️ A DEAD FEED IS STILL §11.4, NOT YESTERDAY. The fill runs only on a series read; a feed that published nothing still degrades to the configured static_profile. The two are indistinguishable to the optimiser - both are 100 % provisional, so arbitrage refuses on the firm-pair rung and cheap_now() is False - so preferring yesterday would change a documented degradation for a difference only the status page can see. DECISIONS/FCST-04-the-day-that-is-carried.md carries that and two more.

⚠️ A BROKEN CACHE IS NOT A BROKEN CONTROLLER. No /data, an unreadable file, a schema this build does not know (including a version of 1.0, which == 1), a day record that is not a record, a malformed point - each its own state with its own reason, none of them a price and none of them an empty series. In every one the plan is still a real provider series and the controller still regulates; the horizon is just as short as it was before this card. .words never raises, because Controller.__init__ reads it unguarded and a status line that throws is an add-on that does not start.

⚠️ AND WHERE THERE IS NO /data, NOTHING IS RECORDED AT ALL - not even in memory. An in-memory yesterday answers for one run and is gone on the next restart, which is a cache that forgets without saying so; the honest pair is unavailable on the status row and no prices carried.

⚠️ "YESTERDAY" IS A LOCAL DATE, AND THE ARITHMETIC IS ON THE DATE. brussels() renders at a fixed offset, so subtracting timedelta(days=1) from it subtracts 24 absolute hours - and the Brussels day before a spring-forward is 23 hours long. Between 00:00 and 00:59 on the morning after the March transition that lands on the day before yesterday. No option was added and config.yaml is untouched.

0.9.0

⚠️ MINOR FOR NEW FUNCTIONALITY, NOT FOR A BREAK - AND THAT DISTINCTION IS THE POINT. 0.8.0 was minor because a config that started on 0.7.0 could be REFUSED on it (rule 10 against 0.7.0's own default slew_w: 1000). Nothing of that kind is true here, and it was checked rather than assumed:

  • options: and schema: both hold 71 top-level keys, the same 71 as 0.8.0. The one schema addition is a per-entry key, capacity_kwh: float(0.1,200)? - note the trailing ?, it is OPTIONAL.
  • An unmodified 0.8.0-era config validates clean on 0.9.0. Measured on both the flat single-inverter shape the reference install runs and an N=2 roster with no capacity_kwh on any entry: 0 problems each.
  • The two refusals OPT-09 adds fire only on configs that USE the new key - an unparseable value, or the key stated on one roster entry and left empty on another. Neither can reach a config written before the key existed.

So: existing installs upgrade untouched, and the bump is minor because the option surface and the behaviour grew.

Contents, in merge order since 0.8.0 (06661c5):

3d29993 UX-02 - the validator's refusals, next to the field, before the save
fdb3b69 OPT-09 - the weights parameter nothing ever passed, and what it cannot do
fcaa724 PKG-09 - refuse a deploy that would be a no-op, or that the add-on would reject

UX-02 builds the real configuration surface in the ingress panel, beside the Supervisor Configuration tab that cannot be removed. The prize is not styling: validate.py writes long cross-field refusals the Supervisor UI structurally cannot show, and until now an operator met them as exit 78 in a log, after saving and restarting. ⚠️ Two config surfaces now exist and the DECISIONS record names the stored options blob as authoritative, neither UI.

OPT-09 makes the architecture's one free parameter real. main.py called resolve() without weights, so the split was a fixed 50/50 regardless of what either pack could deliver; it now passes SoC- and capacity-aware weights.

⚠️ OPT-09 SHIPS A DISCLOSED DETECTION REGRESSION AT N=2. delivery. delinquent() reads an ABSOLUTE 500 W gap, so weighting a low-headroom unit down to a small share puts a unit delivering none of what it was asked under the threshold. Measured: a wedged inverter goes from named on 199 of 200 cycles to 0 of 200 at a load its sibling can carry alone. The alarm returns once the healthy pack saturates - swept, that is a 5000 W load on the fixture, below the proportional-regime formula's 6500 W and not above it. ⚠️ N=1 IS UNAFFECTED: allocator.plan() returns before weights are read at all. ⚠️ CLOSED BY SAFETY-43 ON THIS BRANCH - see its section below; the regression above is history, and the record of it is kept because the measurement that found it is what the fix is graded against.

PKG-09 adds tools/predeploy_check.py. ⚠️ RUN IT BEFORE DEPLOYING THIS RELEASE - it is what caught the fact that 0.8.0 had five runtime commits behind it, which is why this section exists:

docker run --rm -v <repo>:/w:ro goodwe-addon-checks:1 \
  python3 /w/goodwe_controller/tools/predeploy_check.py \
  --deployed-version 0.8.0 --options /w/live-options.json

Exit 0 cleared, 1 REFUSED, 2 NOT CLEARED. ⚠️ 2 is not a pass.

✅ RUN AGAINST THIS RELEASE, 2026-09-07: CLEARED, exit 0. The reference install's options were exported from the Supervisor (70 keys) and checked twice

  • the stored blob as-is, and the effective post-upgrade config, being those 70 keys merged over 0.9.0's 71 defaults. Both pass. max_w 5000, slew_w 400 against a rule-10 ceiling of 555.6 W.

⚠️ THE STORED BLOB HAS 70 KEYS, NOT 71, AND THAT IS THE INTERESTING PART. delivery_hold_s arrived with SAFETY-42 in 0.8.0, so an install running 0.7.0 has never stored it - and it is REQUIRED in the schema, no trailing ?, which is the shape that becomes exit 78. It resolves to its options: default of 185, because the Supervisor sets App.options = deepmerge(config.yaml defaults, stored options); tools/supervisor_selfapi_probe.py §D pins that against a real Supervisor image rather than assuming it. The second check above exists because "your saved settings are valid" and "what the box will actually run is valid" are different questions, and only the second one matters.

⚠️ THE VERSION WENT UNBUMPED FOR THE THIRD TIME IN THREE DAYS - PKG-06 six merges, PKG-07 six, this one five - and this time it was caught by PKG-09's own tool during PKG-09's review rather than by a person. ha apps update against an unchanged version installs nothing and reports success. PKG-10 carries the post-merge alarm so that noticing stops being a human's job.

Unreleased

⚠️ THIS HAS NO VERSION AND CANNOT REACH AN INSTALL UNTIL IT GETS ONE. PKG-06's and PKG-07's rule: the Supervisor keys the built image by version:, so ha apps update is a silent no-op on an unbumped change. This branch deliberately does not pick the number, because the right one depends on a fact the branch cannot observe - whether 0.8.0's image has already been built and pulled. If it has not, this belongs inside 0.8.0's section before it ships; if it has, it needs 0.8.1. Whoever deploys decides, and PKG-07 is the record of what happens when nobody does.

this branch UX-02 - a configuration page in the ingress panel, where the validator's refusals can be seen
this branch UX-04 - UX-01's three unmet acceptance criteria: one withdrawn, one built, one re-attributed
this branch TEST-21 - delivery_hold_s's floor re-derived from a harness that is now committed, and the recorded 30.0 s did not reproduce
this branch SAFETY-43 - delinquency measured against the ask as well as against a flat 500 W, closing OPT-09's disclosed detection regression

⚠️ SAFETY-43 CLOSES THE DETECTION REGRESSION OPT-09 DISCLOSED, AND IT IS A TWO-INVERTER FIX. N=1 IS BYTE-IDENTICAL. delivery.delinquent() named a unit whose shortfall exceeded an absolute min_w = saturation_w = 500 W. OPT-09's weights shrink a low-headroom unit's share, and shrinking the share shrinks the gap - so a unit standing at +125 W and delivering 0 W, 100 % delinquent, was never named. It now names a unit whose gap exceeds min_w OR exceeds DELIVERY_SHARE_FRACTION (0.85) of that unit's own share. Measured on the same closed-loop fixture, same weights, same detector:

load 1500 W  OPT-09 weights  the old rule    named on   0/200 cycles
load 1500 W  OPT-09 weights  the shipped one named on 200/200 cycles

⚠️ saturation_w WAS NOT LOWERED, AND THAT IS THE POINT. Lowering it would report normal saturation as delinquency on every unit at once - SAFETY-41's four-attempt false-trip regime, "i'm getting really annoyed by the notifications in my HA". This ADDS a second way to be named: all seven of test_delivery.py part 1's existing fixtures answer identically under the old rule and the new one, and the absolute arm's suppression window is still exactly 1000 W / 6500 W.

0.85 is derived, not chosen. admin/goodwe:sim/delivery_window.py --campaign --fractions grades it over the SAME 2640 no-fault runs that produced delivery_hold_s's floor. The worst continuous legitimate episode is 35.0 s under the absolute arm alone (SAFETY-42 §3.3, reproduced in the same run) and 40.0 s at 0.85. ⚠️ THE CURVE HAS NO CLIFF AND THAT IS THE FINDING: swept at twenty fractions from 0.05 to 0.99, everything from 0.45 to 0.99 is 40.0 or 45.0 s - within one control cycle of every other - and below 0.45 it rises gradually to 90.0 s at 0.05. ⚠️ "Zero false namings" is not achievable at any fraction and the record says so; what is zero is false ALARMS - the longest legitimate episode in the whole sweep is 90.0 s against a 185 s hold, so nothing comes within 95 s of notifying anybody at any fraction measured, and 145 s at the shipped one. The N=1 control arm is 0.0 s at every fraction in all 2640 one-inverter runs, and the flapping family is 0.0 s in all 840.

⚠️ CFG-07 GETS ONE CONTROL CYCLE WORSE AND IS NOT FIXED HERE. delivery_hold_s is declared int(30,900) while the measured legitimate worst was 35.0 s; it is now 40.0 s, so the band of schema-legal false-tripping values widens from [30, 35] to [30, 40]. CFG-07 should be re-derived against 40.0 s. ⚠️ IT MUST CLOSE BEFORE INVERTER B IS COMMISSIONED (~2026-09-12), not before the next deploy: the band is UNREACHABLE at N=1 - delinquent() answers {} for every input at a roster of one, so no delivery_hold_s can false-trip on the install running today - and commissioning B is the moment it becomes reachable. ⚠️ AND CFG-07 HAS NO DECISION DOCUMENT IN THIS TREE - it exists as a card reference here and in SAFETY-43's record and nowhere else, so whoever takes it writes DECISIONS/CFG-07-*.md first. SAFETY-43 CHANGES NO OPTION VALUE, NO SCHEMA BOUND AND NO DEFAULT - the fraction is a derived constant with a committed harness behind it, deliberately not a knob, for the reason there is no delivery_w. The one edit to config.yaml is a COMMENT: the delivery_hold_s block described the check as "short by more than saturation_w", which is now only half of it.

No behaviour change at one inverter, asserted rather than argued: plan() is handed a weights mapping that raises if anything reads it and still answers identically at a roster of one (and the same mapping raises at a roster of two, so the tripwire is real), and delinquent() answers {} on all 84 single-unit (share, measured, rule) combinations including 0 of 125 W. DECISIONS/SAFETY-43-delinquency-relative-to-the-ask.md carries the curve, the positive controls and the CFG-07 assessment.

⚠️ TEST-21 CHANGES NO CODE AND NO OPTION. IT CHANGES A NUMBER THIS RECORD CLAIMED. delivery_hold_s: 185 shipped resting on "30.0 s, the worst continuous legitimate episode at the shipped threshold across all 2640 runs" - from a harness DECISIONS/SAFETY-42-unit-delivery.md §1 deliberately did not commit, because it imports plantsim and frame_check out of admin/goodwe. A shipped safety constant the next reviewer cannot re-run is PROC-01's shape.

The harness is committed now, in admin/goodwe as sim/delivery_window.py, beside sitesim.py. It is there and not here on purpose: those two modules are that repo's, and restating them in this tree is the CI-08 coupling that has broken three times. The dependency runs one way instead - this repo's control, arbiter and the shipped delivery.delinquent() are imported live out of whichever checkout is under test. Re-run it with:

cd goodwe/sim && GOODWE_ADDON_REPO=/path/to/goodwe-addon \
    python3 -B delivery_window.py --selftest --campaign --blag

⚠️ AND 30.0 s DID NOT REPRODUCE - IT IS 35.0 s. Reported as measured rather than adjusted to agree. What DID reproduce is the part the compatibility promise rests on: the N=1 control arm is 0.0 s at every threshold in every run, and the flapping family is 0.0 s everywhere in all 840 runs. What did not: the headline (one control cycle worse), the reversal family (20.0 → 30.0 s), the non-monotone curve (this rebuild's is monotone, so that finding is now an argument and not a measurement), and the low-threshold rows, badly. The B-lag rows moved the other way - a hypothetical unit four times slower than A gives 75.0 s, not 90.0 s - and they are relabelled throughout as a sensitivity study on a hypothesis about inverter B, which does not physically exist yet, rather than as a measurement of it.

delivery_hold_s is NOT changed. 185 s is 5.29× the re-measured worst (was claimed 6.2×), 2.47× the four-times-slower case, 6.2× the firmware's LINK_STALE_S veto and 4.9× inside the billing quarter: all four bounds still clear and none narrowly. ⚠️ One consequence is worth an operator's attention: at 35.0 s the rig's floor is now above the schema's own int(30,900) minimum, so delivery_hold_s: 30 is below a measured legitimate episode and would report on ordinary saturation. The option is marked derived, do not change; raising the schema floor is left to its own card.

⚠️ UX-02 ADDS A SECOND PLACE TO CONFIGURE THIS ADD-ON, AND NO NEW WAY TO COMMAND THE INVERTER. The ingress panel gains a Configuration page beside Home Assistant's Configuration tab. Both edit the same options blob; neither is authoritative, the stored blob is. What the new one can do that the old one structurally cannot is show validate.py's CROSS-FIELD refusals - two inverters naming one setpoint_entity, a maintenance_charge_w above max_w, a flat setpoint_entity left set beside a roster - next to the field, before saving, instead of as exit 78 in a log afterwards. The Supervisor's tab knows only types and ranges and has no way to express a rule spanning two keys.

Four properties are the ones that could hurt somebody, and each is checked rather than asserted (test_selfconfig.py):

  • a blob the shipped validator refuses is never written - because an invalid blob plus a restart is exit 78, and the panel goes down with the add-on;
  • a blob that changed underneath the page is refused, not clobbered, and the keys that moved are named. Two surfaces, one blob;
  • every message comes from the shipped validator. Proven by inserting one new rule into a COPY of validate.py and watching it arrive on the page with every UI file byte-identical;
  • nothing on the surface commands an inverter or clears a latch. Saving does not even restart: applying options costs a control interruption - the wind-down commands 0 W on every inverter - so that is a separate button that says so first.

⚠️ NO SCHEMA CHANGE AND NO CONTROL CHANGE. config.yaml is not modified at all by this card: the permissions the panel needs - ingress: true, ingress_port: 8099, hassio_api: true, homeassistant_api: true - were already declared, and the panel was already live. tools/supervisor_selfapi_probe.py re-measures them against Supervisor 2026.08.0's own code, and found things the card had wrong: Supervisor's own /addons/self/options/validate is not reachable from inside an add-on, and the Configuration tab can be removed - at the cost of all 71 options, which is why it stays. DECISIONS/UX-02-two-config-surfaces.md carries both.

⚠️ UX-04 CHANGES NO BEHAVIOUR, NO SCHEMA AND NO DEFAULT. It adds one check file, three assertions to a probe, and a decisions record; config.yaml, translations/ and every module under app/ are byte-identical to 6e7b233. It closes out UX-01, which shipped in 0.7.0 and is live, with three criteria that were never met:

  • AC 3 - "the visible count drops to ~15" - is WITHDRAWN as unsatisfiable. options: and schema: declare the same 71 keys, so the set HA's show unused optional configuration options toggle can hide is empty, and Supervisor's own UiOptions marks 59 of the 71 required - the frontend shows those unconditionally, so 59 is the floor even with options: emptied altogether. The target was ~4x below what any manifest can reach. ⚠️ And the 12 hides that are expressible would be bought with the deep-merge: a key absent from options: has no default for the Supervisor to merge into a 0.7.0 box's stored blob, which is exactly the delivery_hold_s mechanism that makes this release's upgrade safe rather than exit 78. The count was printed by tools/supervisor_shape_probe.py §F from the day it was written and never graded, which is how this passed review; it is now three assertions, and removing one key from options: turns two of them red.
  • AC 4's third clause - the AST check for stray in-code literal fallbacks - is BUILT, as test_defaults_pin.py. It discovers the six *_OPTION_DEFAULTS mirrors from the tree rather than naming them, grades all 30 mirrored keys against config.yaml, and freezes the CFG-03 backlog at exactly today's 27 (module, key) pairs so it can only shrink. It found one previously unreported divergence: main.py answers a missing target_grid_w with 0 where config.yaml ships -10 - unreachable on a Supervisor install, recorded rather than corrected. Its red direction runs on every invocation, and a literal planted in the real tree was shown red.
  • AC 5 / the CFG-04 double-literal max_w hole is closed, by UX-02's bcee235 and not by UX-01's fef6ef2. Re-measured on this branch: the 2000 -> 2500 triple mutation is RED at test_selfconfig.py, where it survived 21/21 green on 0.7.0. The attribution is corrected in DECISIONS/UX-04-the-configuration-tab-and-the-defaults-pin.md; nothing was re-done.

The 8 per-entry inverters: translations stay. They are shipped, validated and measured not to reach the Supervisor tab - ha-selector-object labels those fields fields[name].label || name and the converter sets no label - and UX-02's ingress panel is the surface that can render them. A written decision, not a change.

0.8.0

⚠️ A CONFIG THAT STARTED ON 0.7.0 CAN BE REFUSED ON 0.8.0, AND THAT IS WHY THIS IS A MINOR BUMP. SAFETY-39 adds validator rule 10, which refuses an explicit slew_w above SLEW_RAIL_FRAC x the site rail, where SLEW_RAIL_FRAC is LOOP_TICK_S / PLANT_SETTLE_S = 2/18. On a 5000 W rail that ceiling is 555.6 W.

⚠️ THE VALUE THAT BREAKS IS 0.7.0'S OWN SHIPPED DEFAULT. slew_w defaulted to 1000 and the schema was int(50,5000); 1000 > 555.6, so an install that never touched the key and simply took the default is refused on 0.8.0 until the value is lowered. That is as backward-incompatible as it gets, and it is the whole justification for MINOR over PATCH.

The schema also widens from int(50,5000) to int(0,5000), and slew_w: 0 - a value that was not legal before - now means follow the rail and is the shipped default. This is a new capability rather than a changed meaning.

⚠️ Refusal is SystemExit(78) (EX_CONFIG): the add-on does not start. Read the live options and check them against the ceiling BEFORE ha apps update. That check is NOT performed by this PR and cannot be - see the PR body.

CFG-04's rule and PKG-06's: the Supervisor keys the built image by version:, so shipping a change without a bump means ha apps update is a silent no-op. Six merges accumulated behind an unbumped 0.7.0 before this was caught, for the second time in two days. The automated check that would catch it without a human noticing is still unwritten, and that is PKG-06's standing follow-up.

Contents, in merge order since 0.7.0 (bbc903b). ⚠️ Each row carries the merge subject's whole claim, including the half that is not flattering:

9e42cec CI-06 - test_peakguard.py answered two of its checks with the wall clock
24c3d87 SAFETY-38 - pin site_standing with shares that cannot answer for the site
a4290d3 SAFETY-39 - slew_w is a ratio to the rail, and gain is the constant that is still wrong
c8dcb38 SAFETY-37 - a stale reading is None, and arrival cannot be what says so
0581648 SAFETY-13 - the output freeze gets an exit, and only where it needs one
464d398 SAFETY-42 - a unit that stops delivering, and the discriminator the card asked for does not exist

⚠️ TWO DISCLOSED RESIDUALS SHIP IN THIS RELEASE. SAFETY-13's bounded freeze-exit shows 0 spurious releases on the sweep's measured-plant slice but 2 of 272 on a finer grid, and the docs carry the 2-of-272 figure rather than the flattering one. SAFETY-42's card proposed a discriminator that turned out not to exist, and the branch says so rather than shipping a weaker check under the original name.

0.7.0

⚠️ SCHEMA CHANGE, AND IT IS WHY THIS IS A MINOR BUMP RATHER THAN A PATCH. SAFETY-32 adds bms_soc_floor: int(0,50) as a required per-entry key on the inverters roster - no trailing ?. A config that declares a roster and omits it on any entry is REFUSED at startup. An install running inverters: [], which is every single-inverter install including the reference one, is unaffected: the flat bms_soc_floor still describes the one pack.

CFG-04 recorded the rule this follows - the Supervisor keys the built image by version:, so a schema change without a bump is a schema nobody reads.

Contents, in merge order since 0.6.0 (2d025ee):

3934ad7 MAINT-05 - one recalibration per pack, migration graded against the roster
67e649a SPIKE-04a - inverter B and pack B recorded, from datasheet and serial
3993f9f SAFETY-32 - per-pack bms_soc_floor, rule 8 per unit, package-wide roster pin
f72c48d UX-01 - add-on configuration in English and Dutch
86eaef2 TEL-07 - a second MQTT device for inverter B; A's identity byte-identical
4482cd8 SAFETY-41 - the clamp alarm stops narrating normal anti-windup

⚠️ 0.6.0 WAS NEVER SECTIONED. Its content sits below this heading rather than under one of its own, because the bump shipped without cutting the section. That is a defect in this file, not in the release: the deployed 0.6.0 is 2d025ee and the table above is what is new since it. Splitting it retroactively would mean guessing a boundary; saying so is more useful than a guess.

Detail notes — accumulated, NOT a separate release

⚠️ THIS HEADING USED TO SAY "Unreleased" AND IT WAS WRONG. Everything below has SHIPPED. The section accumulated across 0.6.0, 0.7.0 and 0.8.0 because each release was cut without clearing it, so it names tickets from all three (SAFETY-18 and SAFETY-30 from the 0.6.0 era through SAFETY-42 in 0.8.0). A reader who trusted the old heading would have concluded that shipped, running behaviour was still pending — and there was a SECOND heading saying the same thing further down, from the 0.4.x era.

Retitled rather than re-sorted, on purpose: splitting ~3000 lines by release is real work that does not belong inside a version bump, where it would bury the one line that changes what the Supervisor installs. Card PKG-08 carries it.

⚠️ THE OUTPUT FREEZE NOW HAS AN EXIT, AND ONLY WHERE IT CANNOT END ON ITS OWN (SAFETY-13). While the loop is frozen the command's magnitude may fall but never rise; at prev_w == 0 there is no magnitude left to fall, so a charge cannot start. That refusal is deliberate - the inverter reporting power we did not command means another writer is on the actuator, the §1.5 non-goal - and it is kept. What it did not have was an END: nothing cleared it but the other writer leaving.

The exit is now explicit, and which freezes get one is the decision rather than how long:

  • A divergence a limit could have produced - the inverter doing less than the command, in the command's own direction - clears itself, because the command is pinned at something the inverter can reach. It gets no exit, and that is release/1.0's behaviour kept unchanged.
  • A divergence a limit could not have produced - the inverter overshooting the command, or producing the opposite sign - may not clear itself at all, so it gets one. It releases once the divergence has outlasted the plant's own measured settling time: SETTLE_CYCLES = 12 cycles at the measured tick.

⚠️ THE BOUND COMES FROM THE SLOWER OF THE TWO DIRECTIONS THE PLANT WAS MEASURED IN. NOTES.md §5.10 timed the same 1.78 kW step both ways - ~18 s up, ~23 s down - so PLANT_SETTLE_DOWN_S (23 s) joins PLANT_SETTLE_S (18 s) as a named constant. SAFETY-39 uses 18 correctly, because its bound is a refusal and the looser number refuses less; this bound asks how long the plant may still be the explanation, and there the longer number is the safe one. A bound of 9 derived from 18 fires the exit on a single inverter with nothing else on the bus - measured in the container, 62 of 272 load-step pairs at the plant's own measured shape, against 2 at 12.

⚠️ freeze-released IS A PLACE TO START LOOKING, NOT A FINDING. It says the divergence outlasted the plant's measured settling time. It is not proof of a second writer: a large load or PV swing can leave our own power coasting outside our own command's interval, and a plant slower than the one that was measured does the same. DOCS.md now gives the innocent causes first and the second writer only when the state stands.

⚠️ RELEASING THE OUTPUT FREEZE DOES NOT UNFREEZE THE LOOP. The integrator freeze is untouched, so the command can only walk, one slew step per cycle, toward an accumulator that stopped accumulating when the freeze engaged. Measured at the live install's shape (max_w 5000, slew_w 400, target_grid_w -10) with another writer holding the pack at +700 W and 2 kW of export standing: the command holds at 0 W, starts on the twelfth saturated cycle and settles at -1190 W against a frozen integrator of -1194 W, not at the 5000 W rail. On release/1.0 @ c8dcb38 the same run held 0.0 W on every cycle, for as long as the other writer stayed.

⚠️ THIS IS NOT A REGRESSION FIX AND IT ESCALATES AT TWO INVERTERS. The unbounded block is release/1.0 behaviour, confirmed cycle for cycle against SAFETY-04's branch. At a roster of two, actual_w is the SITE SUM, so the comparison is a site command against two units' power and one unit still moving after the other has stopped can put the site into the block with no external actor at all. ⚠️ That escalation is read from the code and from single-unit runs; it is not measured on two inverters. Inverter B does not physically exist yet and sim/plantsim.py's INVERTER_B is INVERTER_A copied with measured=False, so any two-inverter figure would be two copies of A.

Graded against release/1.0 over the 3780-case sweep in test_control.py: 3267 cases bit-identical, 432 releases, 27 of those change the command - every one a charge from prev_w == 0 that release/1.0 refused to start - and 81 differ in the saturation counter alone, because its ceiling moved with the bound from 10 to 13. That ceiling change also removes a degenerate setting: config.yaml accepts saturation_cycles up to 10, which is now strictly below the release bound, so no accepted configuration can stop the block engaging. At the old bound of 9 a setting of 9 or 10 deleted it silently.

⚠️ THE SITE TARGET IS NO LONGER SPLIT 50/50 BETWEEN TWO PACKS (OPT-09) - AND THIS ADDS A PER-ENTRY OPTION, SO IT IS A SCHEMA CHANGE. capacity_kwh: float(0.1,200)? joins the inverters roster as an optional per-entry key. Optional, where SAFETY-32 made bms_soc_floor required, and for that card's own reason: a missing cut-out would have to be defaulted and one default for two batteries protects the shallower pack with the deeper pack's number, whereas a missing capacity has an honest answer - no opinion about the split, every unit weighs 1.0, which is exactly what shipped. It is all or nothing across the roster and rule 9 refuses a partial one. There is no flat capacity_kwh: at one inverter there is no split to weight.

The allocator has had a weights argument since ALLOC-01 and nothing had ever passed one - main.py called resolve() without it and arbiter.py defaulted it to 1.0 per unit - so the split was fixed 50/50 regardless of what either pack could do. Two things now feed it, and they are not the same kind of thing:

  • an ENVELOPE, which is a permission. A new pack UNIT claim at P_SAFETY closes a unit's hi at 0 W when its own SoC is at or under its own bms_soc_floor, and its lo at 0 W at 100 %. The allocator obeys it absolutely, so an empty pack is not asked to discharge and its share moves to the sibling. ⚠️ Not filed at all at a roster of one - every source routes to the site there, so it would bound the SITE TARGET, and SAFETY-25's Option A (no loop-side SoC floor) stands untouched on the shipped install.
  • WEIGHTS, which are a preference. Between those limits each pack is asked for the fraction matching its energy headroom in kWh - not its power rating. The two packs are asymmetric in opposite directions (5000 W / 15.36 kWh against 4600 W / 20.48 kWh from datasheet), so the two ways of dividing hand the work to different packs.

⚠️ AND WEIGHTS ARE A COMFORT CHOICE FOR STABILITY, NOT FOR DELIVERY. ARCH-01's convex combination guarantees a bad split cannot destabilise the site; it says nothing about whether the site can regulate. Measured (two 2000 W units, one at its floor, modelled plant, real compute()): at a 3000 W load the weighted arm and the shipped arm command the identical +2000 W into the empty pack and deliver the identical 2000 W, because _fill()'s last-resort pass hands the remainder to a zero-weighted unit rather than leave watts unplaced. Closing the envelope does not recover those watts either - it reports them: unmet_w becomes +2000 W and the action log says so, where before the record read impeccable. A unit that cannot deliver still parks the site short by its share, and that is now visible instead of silent.

Also: arbitrage.decide() is sized per pack rather than at the site rating on both sides, so a two-pack site cannot ask to buy 9600 W with one pack able to absorb it; and a 0 W sizing is refused by name, because a 0 W arbitrage claim is a park order that outranks the loop. ⚠️ The sell side is a no-op on every roster today - the sell gate reads the emptiest pack, so it refuses outright in exactly the states where the sum could be smaller - and moving that gate is deliberately not this card's; DECISIONS/OPT-09-soc-aware-weights.md §6 says why.

⚠️ SAFETY-42's end-to-end fixture moved, and its finding did not. That card's evidence was that a wedged unit and a pack at its floor are byte-identical in the power domain. After this card the cold pack is no longer asked, so the shares differ - but the two quantities SAFETY-42's rejected discriminator reads (saturation persistence and |grid error|) are still inseparable on both arms, so the conclusion is unchanged and is now stated on the predicate's own inputs. test_delivery.py part 4 carries the whole argument. The two cards meet at one hazard from opposite sides: OPT-09 stops the site ASKING a pack whose SoC says it cannot deliver; SAFETY-42 alarms when a pack that said it could does not.

⚠️ AND THIS CARD NARROWS SAFETY-42's DETECTION WINDOW. IT IS A DETECTION REGRESSION AT TWO INVERTERS AND IT IS DISCLOSED RATHER THAN FIXED. An earlier draft of this entry and of DECISIONS/OPT-09-soc-aware-weights.md §5 said a wedged unit's weight does not move, so OPT-09 could not see the case at all. The ENVELOPE half is true - a wedged box reads a healthy SoC and nothing closes. The WEIGHT half was false: a weight is a function of a pack's ENERGY HEADROOM, not of what the pack delivers, so a wedged unit's weight moves whenever its headroom differs from its sibling's. And delivery.delinquent() names a unit only while its shortfall exceeds saturation_w - 500 W in absolute watts - so shrinking the share shrinks the gap below the threshold and the alarm stops firing. Measured end to end with the real loop, the real allocator and the real detector, on a unit wedged at a healthy 15 % against its own 10 % floor (a SAFETY-42 true positive by that card's own definition): at a 1500 W load the healthy pack can carry alone, equal weights name it on 199 of 200 cycles and these weights name it on none of the 200 - shares 1505/125, gap 125 W, and 125 W is under the threshold. The suppression window widens from a site target below 1000 W to a site target below saturation_w * (w_A + w_B) / w_B, which on that fixture is 6500 W of a 9600 W site; above it the healthy pack hits its own rating, the allocator's last-resort pass hands the wedged unit a big share again and the alarm returns. So in the quiet regime - where unmet_w is 0, the meter is satisfied and no action-log line fires - a wedged inverter with less energy headroom than its sibling can now go unreported at ordinary house loads.

⚠️ BOTH BOUNDS ARE ARITHMETIC ABOUT _fill()'s PROPORTIONAL REGIME AND NEITHER IS A REACHABLE STEADY STATE. Swept on this fixture, the healthy pack's own 5000 W rating binds FIRST: suppressed 0/200 up to a 3000 W load, 4/200 at 4000 W, 41/200 at 4900 W (site target 5320 W, the largest reached with the wedged unit still under 500 W), then 195/200 at 5000 W once _fill() pins A at its cap and hands B 3000 W. So the alarm returns BELOW the 6500 W formula bound, not above it. The equal-weights 1000 W bound is unreachable for the same reason - the equal arm names the wedged unit 199/200 at every load swept, 1000 W included.

test_packshare.py part 8b grades it and pins the CURRENT behaviour, so the day it changes a named check moves. Closing it means making delinquent() relative to the ask rather than absolute, which is SAFETY-42's code and a design change; that is filed as its own card and is deliberately not done here. ⚠️ Every two-unit figure above is two copies of inverter A through a modelled plant - inverter B does not exist yet - and B's ratings are datasheet and serial.

⚠️ AN INVERTER THAT STOPS DELIVERING ITS SHARE IS NOW REPORTED BY NAME (SAFETY-42) - AND THIS ADDS AN OPTION, SO IT IS A SCHEMA CHANGE. delivery_hold_s: 185 joins options: and schema: (int(30,900)). The Supervisor keys the built image by version:, so this needs a bump before it ships - see the 0.7.0 heading above, which makes the same point about bms_soc_floor. The key is ADDITIVE and defaulted, so an existing options blob stays valid; what a missing bump costs is that nobody's Supervisor re-reads the schema.

Two or more inverters only, and at one inverter it is inert by construction. A unit standing at a discharge share it is not producing - short by more than saturation_w, with nothing this add-on can read to explain it, while at least one sibling is NOT in that state - is named after delivery_hold_s. That fault was invisible to everything: the per-unit sign check needs OPPOSITION and a unit at 0 W is not opposing but ABSENT, the site sum still agrees with the meter in direction, circulating power is exactly zero when one unit does nothing, and the only remaining trace is the saturation freeze - which clamp.py itself calls an alarm operators learn to ignore. It is HW-01's shape, which ran 6 h 25 m.

⚠️ IT REPORTS. IT DOES NOT ACT. Nothing is commanded differently, the loop is untouched, control.py is not modified, and the site goes on running short by that unit's share. Commanding an inverter that has stopped listening achieves nothing (HW-01), and the only re-allocation this add-on can express is all-or-nothing - measured on the rig, dropping a unit derated to 50 % from the split leaves the site 400 W worse than keeping it, and this detector cannot tell that unit from a wedged one. The status row is a CAUTION, not a failure, because the controller has not stopped.

⚠️ THE CARD'S OWN DISCRIMINATOR WAS FALSIFIED, AND THAT IS THE MAIN CONTENT. SAFETY-42 asked for "saturation persisting past N while |grid error| > X, both derived". Built and run on the two-master rig first, it fails in both directions, and no (N, X) fixes either: a pack at its own floor and a wedged unit are identical on all 120 cycles of a run in grid, site target, every share and every measured watt - so the benign case fires - and with a sibling that has headroom the standing grid error collapses to 30 W while the wedged unit stands at a +770 W share delivering nothing, so the real case does not. What replaces it is a per-unit shortfall plus two reductions the card did not ask for: an ACCOUNT (the pack's own bms_soc_floor, the only non-power fact that separates an empty pack from a wedged one) and a PROPER SUBSET of the units asked to discharge (which is what keeps a whole-site derate out, and what makes this inert at N=1 - measured zero in all 1890 one-inverter runs).

The report survives a Home Assistant restart (SAFETY-34) under unit/<name>/delivery_tripped, with one notification id per unit, re-raised on the first cycle of every process and cleared by the same Start press as the other latches. Charge shares are deliberately not graded - there is no configured charge ceiling to explain a constant-voltage taper with, and arming that direction would fire on every maintenance charge. DECISIONS/SAFETY-42-unit-delivery.md carries the campaign (2640 healthy two-inverter runs plus 1890 at one inverter as the control), the inverter-B sensitivity sweep the margin is sized on, and the mutation ledger.

⚠️ AND THE TWO THRESHOLDS IT READS ARE NOW GRADED AT A CONFIG THAT IS NOT THE SHIPPED ONE. saturation_w and each unit's bms_soc_floor are handed to this check from the running config, and the promise that comes with that - raise saturation_w and this check moves with you, there is no fourth copy of a default to keep in step - is only true while the call site passes the configured value. A literal equal to the shipped value keeps every fixture green and removes the promise silently, and two such literals were survivors of all 23 suites - measured, not argued - because no fixture that reaches this check had ever run at a saturation_w other than the shipped 500 or at a bms_soc_floor other than the shipped example's 10. Part 4b of test_delivery.py now runs the same fault at a raised saturation_w and at two cut-outs that bracket 10 from both sides, and each pair must answer two different ways - so no constant passes. §9 of the decision record enumerates every number this check reads and says which were already pinned this way and which were not.

⚠️ A PER-INVERTER POWER READING THAT HAS STOPPED FOLLOWING ITS OWN COMMAND IS NOW None, NOT A HELD NUMBER (SAFETY-37). Inverter.batt (register 0x0518) goes through a freshness gate: unchanged for >= 35 s while the standing command is over 250 W and has travelled over 250 W since the reading last moved. A stale reading is a missing input, which §11.1 rule 1 already answers with 0 W and keeps commanding.

This is a behaviour change at the shipped roster of one, and it is deliberate. Before it, a frozen power register read as a healthy measurement for ever - which is HW-01, where a value held for 6 h 25 m while the pack drained to its floor and every detector read healthy. A healthy install is byte-identical: sixty reads of a dithering register under a reversing command all reach the consumers unchanged, asserted rather than assumed. A false verdict fails toward 0 W, behind the existing stale_input_s hold, and clears itself the moment the register reports a different value.

At two or more inverters it also removes two false alarms that had no gate at all: SAFETY-30's per-unit sign check no longer trips on a frozen reading (measured: it trips without the gate and NEVER with it - the tick index is deliberately not quoted, because it is counted on the wall clock inside cycle() and is therefore load-dependent; the checkable statement is the presence or absence of the trip, which part 3 grades), and SAFETY-31's circulating-power sensor reports None instead of a loop that is not happening.

No new configuration key, and no schema change. The bound is derived from circulation_hold_s and unit_sign_disagree_*, which the checks read out of config.yaml at both ends - so moving either default takes the gate red rather than leaving it silently too slow. DECISIONS/SAFETY-37-freshness-policy.md carries the derivation, what TEL-06 and TEL-08 still owe, and three named survivors - including the largest: this detects a value that STOPPED, not a value that is WRONG.

⚠️ slew_w IS A RATIO TO THE RAIL NOW, AND ITS DEFAULT CHANGED FROM 1000 TO 0 (SAFETY-39). 0 does not mean "off" and does not mean "unset" - it means follow max_w, exactly as integrator_max_w: 0 already does, and resolves to max_w / 9: 222 W at the shipped 2000 W cap, 556 W at the live install's 5000, 1067 W at a ~9600 W two-inverter site. The 9 is PLANT_SETTLE_S / LOOP_TICK_S - an 18 s measured step response against a 2 s meter tick - so the loop takes the plant's own settling time to cross its whole output range at any rail.

An install that has never set slew_w will therefore command smaller steps than it did on 0.7.0, and will converge more slowly after a large disturbance. That is the point rather than a side effect: slew_w: 1000 was derived against a 1500 W clamp in 2026-08 and the live install has run it against 5000 since, which crosses the whole range in 10 s against an 18 s plant. Measured on the owner's system 2026-09-05: a 3.4 kW export drove the setpoint 380 -> 5000 W in five ticks, the battery to -5154 W past a 5000 VA rating, and the grid from 3.4 kW of export to 2.8 kW of import.

An explicit slew_w is still accepted and is never silently reduced. What is new is that a value faster than the rail allows is now REFUSED AT STARTUP (validate.py rule 10), graded against the ROSTER SUM - so slew_w: 1000 with max_w: 5000 will not start. Set it to 0, or to any value at or below max_w / 9. Slower is always accepted, including the interim 400 the reference install has run since 2026-09-05.

⚠️ This does NOT fix the over-absorption, and the record says so at length. Re-deriving the slew removes the >= 900 W setpoint step; the loop still absorbs ~1 kW more than the site needs on a large export step, because that is a gain term and gain: 0.6 was measured and deliberately left alone. See DECISIONS/SAFETY-39-slew-against-the-rail.md §6, and do not read this entry as more than it says.

test_peakguard.py answered two of its own checks with the wall clock (CI-06). The file sits on the required checks / unit (pull_request) context and had a measured ~20 % flake rate. It cost a wrong merge diagnosis (parents green, merge red — read as a semantic merge conflict, it was the flake), a false red on two reviewers' CONTROL runs, and a false "mutation caught" that reached a merged card in four places. A flaky check does not waste a re-run; it manufactures evidence for whichever hypothesis the reader already holds.

Both causes are the control law's own gain 900 / remaining applied to a wall-clock gap the file never intended to have. Neither fix widens anything.

  • The cross-time projection. The "one cycle of the intent form is exactly the delivered form plus the command standing on the wire" check decided the intent form from a second PeakTracker.project(..., datetime.now()) taken after the real cycle had returned, and compared it against a floor decided from the first projection — three lines under a comment saying both run "against the same frozen projection". excess = 900 × (projected − ceiling) / remaining moves at excess / remaining W/s, so at a 1500 W floor the 1.5 W tolerance bought exactly remaining / 1000 seconds: 333 ms with 880 s left in the quarter, 6 ms with 10 s left. The gap between the two statements measured 12.7–39.5 ms over 26 instrumented runs. The check was decided by where in the quarter it ran. It now keeps the Projection object the real cycle graded and decides both forms from it — the clock is out of the comparison and the tolerance is exact, not widened. Measured on a real cycle: re-deciding the delivered form from that object reproduces the controller's own floor to 0.000000000000 W.
  • The fixture's own room. wired_over_limit() laid telegrams with range(0, span + 1, 5), leaving 0–5 s of the open block uncovered by construction, and excess multiplies an uncovered second back up by 900 / remaining. Measured on the shipped file: at 12 s of remaining a fixture that asked for a 1500 W floor delivered 613 W (−59 %), and at 2 s the guard did not engage at all — which fails "the real cycle files the peak claim", "…and the number written to the inverter is the guard's floor" and "the STATUS PAGE row for a floor-limited guard" together. The four-attempt retry could not help: four attempts take ~40 ms and all land in the same dying quarter. Fixed with one telegram stamped at now (what a real meter does, and what the docstring already claimed) plus FIXTURE_ROOM_S, derived from the 1 % accuracy the helper promises rather than picked: net_w × lag / (remaining × want) ≤ 0.01 − lag/900 → 23.6 s → 24 s, at the measured 0.1 s worst-case lag.

Nothing was skipped, disabled or marked xfail — the file still carries all of SAFETY-07 and SAFETY-25's forced-discharge SoC floor, and it gains a check: the delivered form re-decided from the cycle's own projection must reproduce the real controller's number to the bit, which pins the test's decide() kwargs as main.py's actual call rather than an approximation of it. One tolerance got stricter (1.5 W → exact), because removing the clock made exactness possible.

site_standing — the one quantity BOTH site guards are asked about — is now pinned by a fixture whose per-unit shares cannot answer for it (SAFETY-38). app/main.py's site_standing = float(sum(standing.values())) is the first argument of SAFETY-30's latching, site-stopping sign detector and the commanded_w handed to SAFETY-18's looks_frozen(). It was pinned by nothing, and three mutations of it disarmed both guards with the whole suite green. This card changes coverage only: not one byte of app/ moves — the shipped sum is correct and must not be "fixed".

  • ⭐ THE FIXTURE THE SUITE COULD NOT BUILD: per-unit shares EACH BELOW the site gate whose SUM clears it. Two simulated units rated 220 W and 280 W, both obeying exactly, inverted gain, house importing 2000 W — the site commands −500 W against a +2500 W meter and no single share clears the 300 W gate. That is the case the site detector exists for, and it is the only arrangement that can separate sum from the mean and from the largest share. test_watchdog.py part 9a.
  • WHY THE EXISTING FIXTURE COULD NOT. _sign_site, the suite's only N≥2 site fixture, runs shares of about −2500 W each — every one individually over the gate — so sum, mean and largest-share all agree on it. Its values happen to be equal, and a check comparing two things that happen to be equal cannot see the difference it names. MUTATION.md habit 4, ninth instance, inside the site half of the very card that names it.
  • FOUR CANDIDATE REDUCTIONS, FOUR DISTINCT ANSWERS, ONE OVER THE GATE — sum −500, mean −250, max(key=abs) −280, [0] −220 — and that is asserted as a precondition, not described. The asymmetric ratings are load-bearing: equal shares collapse three of the four onto one number, and the smaller unit is first so [0] stays distinct from max(key=abs). The gate is the shipped 300 W; only the hold is shortened, because the hold is a wall clock.
  • ⭐ THE SECOND CONSUMER IS COVERED, NOT SCOPED OUT. The same value is looks_frozen()'s commanded_w at main.py:1926. At the same roster the site rail is 0.95 × 500 = 475 W, so sum = 500 W rails it while 250, 280 and 220 do not. Shipped: the peak guard goes blind on SAFETY-18's conjunction and files floor_w = 0.0. Under both surviving mutations it is not blind at all and files no floor, so the battery may keep importing through a quarter whose billed average is unobservable. test_watchdog.py part 9b. The open quarter is deliberately backfilled with the stuck reading so the mutant cannot reach the same action by the coverage route and mask the difference.
  • AT N=1 NOTHING CHANGES, AND IT IS ASSERTED. On a real one-inverter controller standing has one entry, so sum, the mean, max(key=abs) and [0] are the same number — all three mutations are genuinely equivalent on a shipped install and no N=1 fixture could ever separate them. Printed and checked, beside the site detector still being absent there. Part 9c.
  • ⚠️ A CORRECTION, AND IT IS THE MOST USEFUL LINE IN THIS CARD. An earlier revision of this entry said one of the three — list(standing.values())[0] — was already closed by SAFETY-32's package-wide structural pin, and told future authors not to re-cover it. That was false. It had been measured once, that run hit test_peakguard.py's CI-06 flake (a measured ~20% false-red rate), and the red was recorded as a mutation kill. Re-measured on release/1.0 @ 86eaef2 carrying only that edit: the full 21-file suite is green and test_peakguard.py passes five for five in isolation — the mutation survives. The reason SAFETY-32 cannot see it is not the shape: part 12j taints names bound to roster values and lists accumulated in a loop, and standing is a dict filled by subscript assignment, so it never enters the taint set and sum(standing.values()) is not a roster site at all. 12j's own enumeration on the mutated tree lists main.py:1553, 1555, 1690 — not 1599. All three mutations needed this card; all three are now covered by it. A single red from test_peakguard.py proves nothing — re-run it five times in isolation and name the failing check.
  • ⚠️ AND A ZERO-BYTE SURVIVOR ONE LINE BELOW THE ONE THIS CARD PINNED. Pinning the value site_standing said nothing about where it goes. Swapping the detector's first two arguments — evaluate(site_standing, self.grid, …) → evaluate(self.grid, site_standing, …) — is zero bytes and left the tree fully green, because the check asserted only that "-500 W" appeared somewhere in the banner. It still does: in the meter slot. The swapped banner reads "commanded +2500 W against a meter reading −500 W" — a site charging at −500 W into a +2500 W import, told to the operator exactly backwards, on the one line somebody woken by a latching site-stopping alarm reads first. The check now asserts the ordered pair rather than a substring, and is red on it. No app/ change: the hole was in the test.
  • ⭐ A SURVIVOR THIS CARD WENT LOOKING FOR AND CLOSED. site_standing = float(self.target) — the arbiter's site target instead of the sum of what actually stands on the wire — is −11 bytes and survived the full suite, because in every fixture that existed the two are the same number. They are not when a device's reported range is narrower than its max_w: the device claim is filed per actuator, so it bounds each unit's share and never the site target. A site asking for −500 W while −250 W stands would then take a latching site-wide false trip under its own 300 W gate. Closed by part 9a's device-clamped counterfactual.
  • ⚠️ AND THE SAME ZERO-BYTE DEFECT ONE CALL SITE OVER — THE ONE A SHIPPED INSTALL CAN ACTUALLY SEE. The ordered pair went onto main.py:1620, the site detector. That detector is armed only at N≥2, and part 9c asserts it is absent at a roster of one — so on every install this add-on has, the per-unit banner is the only sign-disagreement sentence that can ever be printed, and its call at main.py:1560 was still unpinned. The identical swap there is 0 bytes and left the tree 21/21 green, and nothing behavioural could ever have caught it: disagrees() is symmetric in those two arguments (commanded_w * against_w < 0, abs() gate on both), so the mutant takes identical actions on every input. What moves is the sentence — measured, 9 emitted banner lines invert in 3 distinct sentences, including the one persisted to sign_reason and read back after a restart: "commanded +1000 W against its own measured power −1000 W" becomes "commanded −1000 W against its own measured power +1000 W". Closed by the ordered pair on both per-unit banners — the N≥2 its own measured power one and the N=1 a meter reading one — with both operands read off the observed cycle rather than off the arguments the detector was handed, plus a precondition on each that the two operands really are different and opposite in sign. Red on four named checks, green in the other twenty files. No app/ change.
  • ⭐ AND THE FAMILY IS NOW ENUMERATED BY MACHINE, because it had been enumerated by hand twice and was short both times. tools/symmetric_message_scan.py finds every call whose argument order is load-bearing for a message rather than for a decision: it renames each parameter pair, erases every formatted string, canonicalises the commutative operators and iterates to a fixpoint (the symmetry is usually one call deep — evaluate() is symmetric only through disagrees()), then classifies each sentence by where it goes. A second census covers sentences the caller builds. It found one open survivor this card does not close and now discloses — rail_unreachable()'s dev_min/dev_max at main.py:3208, 0 bytes, 21/21 green, a status-page row — and twelve unpinned caller-built sentences including SAFETY-31's circ_reason, which is the same shape and is also persisted. The list, the pinned status of every member and the instrument's own blind spots are in DECISIONS/SAFETY-38-site-standing-pin.md §7.
  • ⚠️ AND A LEDGER SENTENCE THIS CARD ITSELF GOT WRONG, CORRECTED WITH THE MEASUREMENT. An earlier revision said "before part 9 existed, three of these left the whole suite green — M1, M2 and M3 — and the remaining seven were caught by SAFETY-30's own N≥2 checks". Eight did. Re-run one at a time on clean release/1.0 @ bbc903b, fresh copy each, bytecode purged, byte delta and main.py fingerprint printed, full 21-file suite every time: M1, M2, M3, M4, M7, M8, M9 and M10 are all 21/21 PASS; only M5 and M6 go red. It is the same species of error this round exists to fix — a survivor recorded as a kill — and the file contradicted itself three times while saying it. And the two that ARE caught make the card's case: M5 (sum(abs …)) and M6 (-sum) are the only two that reverse the sign. Every other entry changes only the magnitude, and the old _sign_site fixture's ~−2500 W shares put nine different magnitudes on the same side of the same 320 W gate. The pre-existing coverage could see a sign and nothing else.
  • 13 mutations — 11 of that line and its call site, plus 2 zero-byte edits to the arbiter claim wiring — each on a fresh full-repo copy mounted :ro, bytecode purged by tools/mutation_run.sh, the edit re-read from disk and the byte delta printed. All 13 red. Every one was re-run independently in this round rather than carried forward from the previous round's report. The claim-wiring pair (sign_site and circulation moved from site scope to unit scope) closes two gaps a reviewer disclosed — though circulation's kill belongs entirely to pre-existing checks and is not claimed by this card. ⚠️ One false red from test_peakguard.py on M10 did not reproduce in four subsequent runs; it is CI-06's known flakiness, no claim here rests on it, and it is recorded rather than quietly dropped — unlike the one that was believed, two bullets up. Ledger, and an enumerated list of what was not mutated, in DECISIONS/SAFETY-38-site-standing-pin.md §4a, §4b and §6a.
  • ⭐ ROUND 4: THE SCANNER COVERED ONE SYNTACTIC SINK AND CALLED IT THE FAMILY, AND TWO LIVE MEMBERS WERE SITTING IN THE HOLE. Every one of census B's 16 members was a sentence that is appended, assigned, or logged. Not one was RETURNED — and census A's return bucket only ever held a callee formatting its own parameters, so a method formatting its own attributes and handing the string back was invisible to both. That is the whole describe() / explain() family, which is where this codebase keeps its operator sentences. Worse than the gap: it was in none of the five blind spots the tool printed about itself. The tool now scans the return sink (census C), resolving it through the returning method's call sites so that a returned key — store.unit_key(), mqtt.unit_state_key() — is not mistaken for a returned sentence; it also scores a sentence handed to a constructor as reason= or placed under a "text" dict key, which added six more caller-built members it had been stepping past. Re-run, it rediscovered both of the members this round was sent to fix without being told where to look.
  • ⭐ ClampResult.describe() — the clamp alarm the owner has been complaining about all day — had a SECOND independent way to lie, and no test_*.py mentioned describe() at all. Transposing requested_w and applied_w in clamp.py:253 is a zero-byte edit that leaves the guard reporting a setpoint clamped UPWARD, in the measured case to +9999 W by a bound whose rating the same sentence gives as 2000 W. It is the §15 action-log row (main.py:1366) and the ClampWatchdog notification reason (main.py:2452). Measured 21/21 green before; now red on 4 checks in test_clamp.py part 6d, pinned on the ordered pair on the contiguous literal at both consumers, with operands read off ctl.target and hass.writes[-1] — what the loop asked and what the device was sent — rather than off the ClampResult the swap lives in.
  • ⭐ PeakDecision.explain() — the status-page banner — the same shape. projected_w ↔ ceiling_w at peakguard.py:493, zero bytes, and the row then reads "quarter projects 5013 W under a 2300 W ceiling": a quarter 2713 W over its ceiling, on a row whose own words say idle and whose own flag says ok. "peak guard idle" appeared in no test_*.py. Measured 21/21 green before; now red on 3 checks in test_peakguard.py part 13, pinned on the decision and on the shipped status row at main.py:3313. ⚠️ A correction the ticket is owed: the idle sentence does not reach main.py:3299/3302 — those are the floor-limited branch, where explain() returns self.reason before the idle literal is built. It reaches main.py:3313 and, on the release edge, main.py:1951.
  • test_arbiter.py's scope-violation check made a claim WIDER than its assertion — it said scope_violations "names the source and the actuator it does not belong on" and asserted "peak" in scope_errors[0], which is still true after the two swap roles. Measured this round: 0 bytes, 21/21 green; now red on 2 checks, pinned on the ordered pair.
  • 14 more zero-byte mutations measured, and 10 SURVIVORS ARE DISCLOSED RATHER THAN CLOSED, each with its file fingerprint and its 21/21 verdict, in DECISIONS/SAFETY-38-site-standing-pin.md §7e–§7g: two in allocator.py's UnitPlan.explain(), three across arbiter.py's two explain()s, two in tariff.py, two in arbitrage.py's trade reasons and one in main.py's SoC-floor notification. The other four of the fourteen are kills: allocator.py:162 was already caught by test_alloc.py, and clamp.py:253, peakguard.py:493 and arbiter.py:264 are closed here. An enumerated list with honest gaps beats a fifth round finding a fifth instance. ⚠️ And the probe that grades those mutations was itself the defect, once. Its first cut numbered the operands by order of appearance, so after a transposition the other leaf took the same number and all thirteen renders came back byte-identical — which reads exactly like the edit is inert. Keying the value to the name fixed it. A measurement comparing the swap against itself, in the instrument this time.
  • The tool now states what it does NOT scan, largest hole first: %s-style lazy logging (_LOG.error("… %s … %s", a, b) puts the operands in arguments, so no census here looks at them and the transposition is the same zero-byte edit — 31 such calls across 8 modules, counted and listed by the tool rather than asserted), .format()/%/+/.join() sentences, a sentence that leaves through a dict or dataclass and is rendered elsewhere, yielded sentences, message attributes outside the reason-shaped set, and everything outside app/. Its five over/under-report gaps stay, and every census row now prints whether the two interpolations share a format spec — the difference between a transposition that is silent and one that merely looks broken.

Inverter B gets its own MQTT device, and inverter A keeps the one it has (TEL-07). MQTT discovery announced one device, and every entity hung off one unique_id prefix, so at two inverters B's per-unit telemetry had nowhere to go. It has one now — without touching a single entity that already exists.

  • ⭐ A's discovery payloads are byte-identical to release/1.0. Same topics, same unique_ids, same payload bytes, same retain flags, in the same order — verified by diffing the announced payloads, not by reading the code: 9 topics, 0 missing, 0 changed, 0 added at a roster of one, and 0 missing, 0 changed, 8 added at a roster of two. That is what protects the live install's recorded history and the three watchdog automations that name its entities.
  • ⚠️ THE ASYMMETRY IS DELIBERATE — DO NOT "CLEAN IT UP". The first roster entry's per-unit rows go on the device it already has; every later entry gets its own device (via_device the controller). "One device per inverter" is tidier and is the change that renames every entity on the live system — and because HA keeps the id it composed at first discovery, a rename produces a new entity beside a dead one: the history stays behind and every dashboard, template and automation goes on pointing at a sensor that quietly stopped updating. The composed ids come out symmetric anyway (sensor.goodwe_inverter_a_battery_power / sensor.goodwe_inverter_b_battery_power).
  • Four per-unit rows — setpoint, battery power, SoC and the SAFETY-02 sign latch — announced only from a roster of two. At N=1 nothing is announced and nothing is published: no second device, no renamed entity, no added topic, asserted rather than assumed.
  • Site-scoped sensors stay site-scoped. grid and p1_sample_age_s are announced once, on A's device, at every roster length 1–6. There is one P1 and one grid connection, and p1_sample_age_s is a watchdog input — a second copy is a second answer to "is the meter fresh?", one of which is always the one nobody is looking at. Circulating power, controller status, maintenance phase and the capacity-tariff peak are site for the same reason.
  • inverter.roster_names() is now the one answer to "what are the units called", read by build_roster() and by the publisher — which has to know the roster before a Controller exists, because announcing happens on the broker's CONNACK.
  • test_mqtt.py, a new suite: the recorded release/1.0 baseline (generated by running that commit's module, not transcribed), the payload diffs, the composed entity ids modelled independently of app/mqtt.py and anchored on the one id verified against the live system (sensor.goodwe_p1_sample_age), the announcement-vs-publication agreement on a real Controller with different SoC, battery sign and latch state on the two units, and twelve mutations of the shipped module, all red, each on a named property.
  • MEASURED, NOT ASSERTED. Three of those properties exist because the mutation table found their absence: dropping the unit from the state topic, moving grid into the per-unit set, and units=() in main()'s publisher call were all green on the first run. So was a roster fallback that named two nameless entries inverter-a. Sixteen mutations were run through tools/mutation_run.sh; the survivors are enumerated with their size in test_mqtt.py part 9.
  • ⚠️ Inverter B does not physically exist (~2026-09-12). Every fixture here is simulated, from the datasheet and serial in NOTES.md §1.1b. Nothing in this card was measured on a second inverter.

The add-on configuration screen now speaks English and Dutch instead of raw option keys (UX-01). There was no translations/ directory at all, so Home Assistant fell back to rendering the option KEYS — an operator opening Configuration read unit_sign_disagree_w, saturation_cycles, integrator_max_w, seventy of them, in file order, with no description and no way to tell a constant derived from 1890 closed-loop test runs from their own inverter's rating. This card changes presentation only: not one default, not one range and not one line of behaviour moved.

  • translations/en.yaml and translations/nl.yaml, with a name and a description for all 70 options and for all 7 per-entry keys of the inverters: repeatable section. The Dutch is written for a Flemish homeowner rather than transliterated: afname and injectie, kwartierpiek and capaciteitstarief, laadniveau, uitschakelgrens — the words that are on the bill and on the meter.
  • ⭐ EVERY DERIVED CONSTANT SAYS WHERE IT CAME FROM AND WHETHER TO TOUCH IT. unit_sign_disagree_s now reads "derived from 1890 closed-loop test runs (SAFETY-30): 85 s is 8.5 times the worst legitimate opposition those runs produce… do not change it without re-deriving"; circulation_w cites its 924 runs and the measured 400 W knee; meter_freeze_s cites the 2399 s capture; bms_soc_floor says it is register 0x0560 read off the pack. The two numbers that are genuinely the operator's — max_w and peak_cap_w — say "THIS IS YOUR NUMBER" instead, and cycle_cost_threshold_eur, which is neither measured nor the operator's, admits it is an open product question (OPT-08) rather than borrowing the others' authority.
  • config.yaml reordered into task order — hardware/entities → meter → ratings and limits → tariff → maintenance → safety → advanced — in both halves, with every comment carried with its key. ⚠️ The rendered order is the schema: half's (App.schema_ui is UiOptions(...)(data["schema"])); the options: half is reordered to match so the file reads the way the tab renders. ⚠️ test_inverter.py part 12's first-match trap is preserved: the nested per-entry max_w: still appears BEFORE the flat one under schema:, and inverters: [] still ships in the options: half. Moving the nested block below the flat one is a 1-byte edit and it was run: red in test_inverter.py and in test_translations.py.
  • MEASURED, NOT ASSERTED. tools/supervisor_shape_probe.py gains a section F that loads both files with Supervisor 2026.08.0's own _read_app_translations() out of the release image (a file that fails SCHEMA_APP_TRANSLATIONS is dropped with a log warning and nothing else), runs its own UiOptions, replays the frontend's label resolution transcribed from the shipped bundle, and prints every rendered row in both languages.
  • ⚠️ ONE MEASURED NEGATIVE RESULT, RECORDED RATHER THAN GLOSSED. The per-entry keys inside the inverters: repeatable section still render RAW. _convertSchemaElement sends type: "schema" with multiple to ha-selector-object, which labels its fields fields[name].label || name, and the converter sets neither label nor translation_key. The fields: translations are shipped and validated because that is the shape Supervisor's own schema defines for exactly this, and a frontend that wires label through would consume them — but on 20250925.1 they do not reach the screen, and this card does not claim they do. The inverters label and description themselves do.
  • A new check, test_translations.py, so this cannot rot. A translation key naming an option that does not exist, or an option with no translation, fails CI — in both directions, for both languages, top-level and per-entry. It is mutation-tested both ways: eleven mutations applied in-process, each required to NAME the key it broke rather than merely to go red, plus a negative control that the unmutated input is clean. Two of the eleven are the ones that cost the WHOLE FILE rather than one label — an unrecognised top-level block, and a network: value that is not a string. Supervisor validates each translation file through SCHEMA_APP_TRANSLATIONS and, on refusal, logs a warning and drops all of it, so those silently return the entire tab to raw keys; neither is reachable through the configuration: coverage, which is why they were hunted for and closed. Six more were run on disk, through the purge-and-re-read protocol: deleting a translation (−65 B), renaming an option in config.yaml (+4 B), adding an orphan key (+47 B), emptying a Dutch description (−711 B), breaking one label's group prefix (−4 B) and deleting a provenance citation (−19 B) each go red.
  • The parser has a licence. There is no PyYAML in the add-on's CI image, so tools/translations_lint.py reads these files by hand — and a hand parser that quietly disagrees with the real loader is the defect this repository keeps finding. The probe imports that same module and asserts, key by key and string by string, that it returns what _read_app_translations() returns. The parser is deliberately strict and raises on anything outside the subset; nine malformed shapes are fed to it to prove it does.
  • ⚠️ WHAT THIS CHECK CANNOT SEE, stated with its size. It grades coverage and provenance citations, not truth. Falsifying a figure inside a description that is not one of the cited tokens survives (run: "8.5 times" → "3 times", −2 B, green), and swapping two options' descriptions survives (0 B, green). Separately and out of this card's scope: changing a shipped default that no suite pins survives — step_w: 10 → 20 (0 B) leaves test_control.py, test_clamp.py, test_validate.py and test_peakguard.py green. That is the same family as CFG-04's DEFECT 2 and the UX-01 rescope moved it to its own card on purpose.

Inverter B's rating is 4600 W, FROM ITS DATASHEET, and every documented copy of it now says so (SPIKE-04a). Three places stated B's rating — config.yaml's commented roster example, DOCS.md's, and tools/supervisor_shape_probe.py's "a blob an operator would POST" — and all three said 3000 W, a number that was never measured, never read off a datasheet, and simply wrong. The owner supplied B's model and serial on 2026-09-04: a GoodWe GW5048D-ES, serial 55048ESU22AW0992, max charging and discharging power 4600 W. No control behaviour changes here; this is documentation and its pin.

  • Serial characters 6-8 read ESU → platform 105, AA55, the supported set. Not ESN/ESC (ES G2, platform 745). SPIKE-01 does not gate this site. ⚠️ A passed platform gate is not a proven control surface: specs.md already calls other platform-105 serials "same protocol family; untested silicon", and this repo's 0x056E/0x056F map was reverse-engineered from a passive tap on one BPS unit. That check is the bench half of SPIKE-04.
  • ⚠️ 4600 W IS FROM A DATASHEET AND IS NOT A MEASUREMENT, and one ambiguity is recorded rather than guessed. The datasheet prints it under Battery Input Data, so it is probably DC, while max_w is graded against 0x0518 — the inverter's own AC power. If it is DC the AC ceiling is nearer 4600 × 0.94 ≈ 4324 W, and the charge direction moves the other way (≈ 4894 W drawn AC-side). Neither reading is written in as fact. SAFETY-20's min(max_w, dev_max) already bounds it correctly under either, once dev_max is read off the unit — so max_w: 4600 is what to configure today. goodwe/NOTES.md §1.1b carries the full record, with the date and the method on every figure.
  • A NEW CHECK, BECAUSE A DOCUMENTATION FIX WITHOUT ONE DRIFTS AGAIN. test_validate.py now pins all three documented rosters: they must be findable, they must agree, and they must say 4600. It also grades the provenance beside the number — the datasheet it came from, the 0x0518 it is graded against, and the 4324 W the DC reading would make it — within 2500 characters of the roster, not file-wide. The first version searched whole files and was already vacuous on two of them, because 0x0518 appeared in config.yaml and DOCS.md for unrelated reasons before this card: a check whose data could not reach the failure it named, in the file that exists to complain about those. Four mutations were run against the fixed version — the probe back to 3000 (0-byte delta), the DOCS.md caveat deleted, config.yaml alone "corrected" to 4324 (0-byte delta), and the probe's entity renamed so the regex finds nothing — and all four are red.
  • THE TEST FIXTURES KEEP 3000 W ON PURPOSE, AND NOW SAY WHY AT THE LINE. test_inverter.py, test_maintenance.py, test_peakguard.py and test_watchdog.py build a second inverter at 3000 W against A's 5000 W. The only property those checks consume is that B's number is unmistakably not A's, and the real pair is a 400 W gap — narrower than slew_w, inside the range where an off-by-one-unit bug and ordinary control arithmetic produce indistinguishable numbers. Collapsing them onto the real values would buy realism those checks do not use and cost them their separating power, which is the defect test_peakguard.py's own §10g precondition exists to prevent. They are illustrative, not B's rating, and no longer a placeholder for it.
  • Two consequences with numbers, recorded in goodwe/NOTES.md §1.1b for the cards that own them. At 94 % battery-to-AC a round trip is ≈ 88 %, so A charging 3 kW while B discharges 3 kW burns ≈ 360 W continuously with the meter at zero — SAFETY-31 argues its threshold from "a few watts" and has no figure. And < 13 W night self-consumption per unit (≈ 26 W for two, ≈ 0.6 kWh/day), which nothing in this add-on accounts for anywhere.
  • The site is asymmetric in opposite directions: A = 5000 W / 15.36 kWh nominal, B = 4600 W / 20.48 kWh — ~33 % more energy, ~8 % less power. No stability implication (ARCH-01's ḡ = Σαᵢgᵢ is a convex combination), but a full recalibration of B moves 33 % more energy and MAINT-05's 12 h drain phase timeout was derived on A; it should be re-checked against B rather than assumed to carry.

Every pack is recalibrated on its own schedule, and only one moves power at a time (MAINT-05). §12's monthly cycle drains a pack to empty and refills it to true its coulomb counter. There was exactly one Maintenance state machine and one un-namespaced history, so at two packs only the first was ever recalibrated and the second's counter drifted forever — and nothing prevented the cycle draining pack A while the loop or arbitrage charged pack B, which is two power-moving phases on one grid connection pulling against each other.

  • ONE Maintenance PER ROSTER ENTRY, each with its own schedule, phase and history under unit/<name>/.... store.migrate_maint_keys() moves an existing install's flat history into the first pack's namespace under migrate_unit_keys()'s three rules — shared in code, not restated — with the same read-back postcondition, and the flat keys are kept live as the rollback view so a downgrade finds a current history rather than one dated migration day.
  • ONE MAINTENANCE SLOT PER SITE. At most one pack may be in a power-moving phase (drain, charge and hold — charge is in the set because a pack pulled full from the grid beside a pack exporting to empty is 4 kW circulating with the meter at zero). The holder is derived from the packs' own stored phases, not persisted, so a restart mid-drain re-derives it. When several packs are due in the same hour the slot goes to the one that has gone longest without a completed cycle; roster order breaks a numeric tie and nothing else. Nothing preempts a cycle in flight.
  • THE DEFERRED PACK IS NOT STARVED AND IS NOT A FAULT. A deferral does not stamp last_start_attempt (that is the 90 min post-abort cooldown, inside a 60 min start hour), and does not move the phase, so neither the 12 h drain nor the 36 h charge timeout — "the battery is not following commands" — can be reached by waiting. It says WAITING, names the pack it waits for, and recalibrates at the next start hour; a test drives the winner's whole cycle and observes it start.
  • THE SCHEDULE IS NOT STAGGERED BY CONSTRUCTION. The interlock defers and the stagger is what comes out of it: one contested month separates two packs by one cycle length and they stay separated. DECISIONS/MAINT-05-per-pack-maintenance.md §3 carries the argument.
  • validate.py rule 6 now grades maintenance_charge_w against the WEAKEST cap on the roster, like rule 5. Its own comment said it would have to move the day maint_unit stopped being inverters[0]; that day is this card. It refuses configurations that used to start — a 3000 W charge beside a 2000 W pack that is now recalibrated too — which is the lo > hi contradiction rule 6 exists to refuse, caught when the config is written. Identical at N=1.
  • AT A ROSTER OF ONE, NOTHING CHANGES, and it is asserted rather than assumed: the state file keeps the flat keys and gains none, the migration does not run, the four cycle events are the shipped strings character for character, and the status banner is the bare phase with no pack name.
  • THE MIGRATION IS GRADED AGAINST THE ROSTER, NOT AGAINST THE NAME IT WAS HANDED (fix round). migrate_maint_keys() takes the roster rather than a pack count and _verify_moves() checks the namespace it wrote against the names the machines actually read. A postcondition that reads back the namespace it was given cannot detect being given the wrong one: handed inverter.UNIT_A on a roster of ["garage", "shed"], the first version of this card wrote all four keys under unit/inverter-a/..., read all four back equal, reported verified, and stamped maint_schema_version — so both packs came up believing they had never been recalibrated and the next start skipped the migration too. That is now misdirected: not ok, the marker is not written, and the next start re-runs and recovers (rule 1 makes the re-run a no-op). build_roster() numbers a nameless roster entry inverter-1, so inverter-a is not even the fallback for a declared roster. Every two-pack fixture that could see this now names its first pack garage; with them all called inverter-a, self.inverters[0].name and UNIT_A were the same string and the swap left all 19 suites green.
  • AND THE REFUSAL NOW SURVIVES THE NEXT START (second fix round). The fix above graded only the keys it had just written, so it refused exactly once: measured at Controller level over one persisted store, roster ["garage", "shed"], with the call site still wrong on both starts — construction 1 ok=False misdirected=4 moved=4 kept=0 marker=<absent>, construction 2 ok=True misdirected=0 moved=0 kept=4 and the marker stamped. On the second start rule 1 finds the wrong keys already there and routes all four to kept, so moved is empty and the roster loop grades nothing — and start 3 skips the migration forever, including after the call site is fixed. Loud-and-recoverable became silent-and-permanent after one restart. _verify_moves() now grades set(moved) | set(kept); both lists are built from the same unit argument, so grading kept grades the same namespace decision. test_maintenance.py part 9c drives two starts with the same wrong unit over one store — the shape nothing in the suite had, since 9b measured recovery along the path where the operator has already fixed the call site.
  • AND THE MARKER GATE IS PINNED ON BOTH GUARDS. if rep.ok: is not lost and not misdirected, and the mutation if rep.ok or rep.kept: stamped the marker on a migration that lost a month of history with all 19 suites green. Part 9d is the fixture that separates the two guards: two keys already namespaced (kept non-empty) and two whose write the store drops (lost non-empty), misdirected empty throughout.
  • ⚠️ AND THE SAME MUTATION ONE FUNCTION UP WAS A SURVIVOR, FOUND HERE AND CLOSED. migrate_unit_keys() — SAFETY-02's latch migration — gates its own marker on rep.ok too, and every check that reached that gate ran on a store where nothing was namespaced yet, so rep.kept was empty in all of them. if rep.ok or rep.kept: there stamps schema_version on a migration that dropped the latch: the guard is off, the file still says sign_tripped: true, and the next start skips the migration that would have re-armed it. Measured a survivor of all 19 files; now red on test_inverter.py part 10, which drops the sign_tripped write beside an already-namespaced sign_reason. No source change — the shipped gate was right; nothing could see it.
  • ⚠️ FOUND, RECORDED, NOT FIXED (SECOND ONE). migrate_unit_keys() — SAFETY-02's latch migration — has the identical hole and it costs a guard rather than a history. It runs before build_roster() (each Inverter restores its latch in its constructor), so it is handed the constant UNIT_A and there is no roster to grade against. On a declared roster a pre-DEV-02 sign_tripped: true lands under unit/inverter-a/sign_tripped, which no unit reads — and _grade_store_migration(), whose job is to re-arm exactly this, is defeated by the key the defect wrote: its "is anything namespaced latched" test is satisfied by the misdirected value itself. Fixing it means naming the migration's target from the config before any Inverter exists, which is inverter.py and SAFETY-02's semantics, with its own battery. Measured and pinned as a running check (test_maintenance.py part 13), whose assertions state the WRONG behaviour on purpose.
  • ⚠️ FOUND, RECORDED, NOT FIXED. A maintenance drain pins its pack while the loop's target is a site claim, so when the site target is below the pin the only split asks the sibling to charge against the drain and allocator.plan() refuses it — the site parks at 0 W and the pack's 12 h timeout would eventually report "drain stuck" about a healthy battery. Pre-existing on release/1.0 at 2d025ee with the unit names swapped; fixing it means changing what the loop's target means while a unit is pinned, which is loop and allocator territory. Pinned as a running check (test_maintenance.py part 12) so it cannot be forgotten.

bms_soc_floor describes a BATTERY, so at two packs it stops being one number (SAFETY-32). The peak guard's energy backstop rests on two figures: the EMS floor peak_soc_floor (the depth a money-saving discharge may never reach) and bms_soc_floor, the percent that pack's own BMS cuts out at — register 0x0560, read as 10 on the reference GW5000S-BP. Rule 8 refuses an EMS floor at or below the cut-out, because such a floor can never bind: the BMS wins and the status page reports a backstop that does not exist. With ONE cut-out for two packs of different models that rule graded the EMS floor against whichever battery happened to be written into the flat key, and a site with cut-outs of 10 % and 30 % under peak_soc_floor: 20 started — the guard would then command a forced discharge that pack B's BMS, not the operator's floor, is the thing that stops. Rule 8's own failure mode, reached through rule 8.

  • bms_soc_floor becomes a per-entry roster key, and it is REQUIRED there. Nothing is inherited: an entry that omits it has no cut-out, does not borrow the flat one, and is refused by name at startup. A per-entry default was considered and declined — a default is one number for every pack, which is the defect this card removes; DECISIONS/SAFETY-32-per-pack-bms-floor.md records the decision and its migration cost. The flat key is unchanged and is now documented as the single-inverter shape's own cut-out.

  • Rule 8 grades EVERY unit and NAMES the one it refuses, through a new unit_bms_floors_indexed() that carries the roster index the value came off. CFG-04 had just fixed a rule 5/6 bug of exactly this shape — a caps-list index fed to a function that indexes the roster, so the message named the wrong inverter — and this reader skips nothing, so there is no second list for an index to desynchronise from. Graded on a roster whose offender is the SECOND entry and on the same two numbers in the other order.

  • The permission is answered PER PACK. Controller.pack_floor_soc — the emptiest measured pack — is untouched and is still what decide() grades; what changed is the floor. peakguard.pack_permissions() answers one (name, reason) per pack against that pack's own floor, and the floor-limited notification now names the pack that stopped the site rather than "the battery". At a roster of one the alarm is byte-for-byte what SAFETY-25 shipped.

  • An unstated cut-out withholds rather than defaults. None, not 0.0 — discharge_permitted() already treats an unknown floor as no permission, so the absence costs a shave and never a pack, including on sim/inject.py's path which does not run the startup gate.

  • ⚠️ Stated rather than hidden: under any config rule 8 accepts, the per-pack floor reduces to peak_soc_floor for every pack — rule 8 makes it so. The reduction is written for unit_caps_indexed()'s reason ("unreachable" is a claim about rule ordering, not a property of a function) and is graded on both sides: 1775 rule-8-valid (peak_soc_floor, bms_soc_floor) pairs answer the option, and the pair rule 8 refuses answers the cut-out. peak_soc_floor itself is still one number for the site, so the "deeper pack needlessly withheld" half is filed as an open question, not closed.

  • tools/supervisor_shape_probe.py re-run and repaired. MUTATION.md habit 8: a committed transcript is a check and it decays. The required key broke §C and left §D printing PASS on a refusal about a different key. §D is now an isolated counterfactual over an accepted, merged baseline, one key varied per case, asserting the key name in the refusal — all cases passed on amd64-hassio-supervisor:2026.08.0.

  • ⚠️ SECOND FIX ROUND — the round-2 fix carried the defect it was written to close, in its prose. Two more rewrites survived a green 19-file suite on 8501e05: binding_soc_floor()'s max(floors) → max(floors[-2:]) (+5 bytes) and the call site's self.packs → self.packs[:2] (+4 bytes). Both are checks whose TEXT claimed more than their FIXTURE could reach — 12c2's only counterfactual varied the last pack, which every window ending at the roster's end follows, and all three 12g runs drove a two-pack roster, where [:2] is the roster. The general law, now stated in the file: a fixture of N packs cannot separate two reductions that agree on N packs, and the regress does not terminate in a fixture — [:1] needed two packs, [:2] three, [:3] four. So the reduction is now graded by a length sweep (78 simulated rosters, lengths 1–12, deepest cut-out at every position, closing head and tail windows of width 1–11 at once) plus a computed family table of fourteen rewrites that goes red naming any member no roster kills; the call site is graded by three-pack runs with the deep cut-out at index 0, 1 and 2, plus an exact structural pin (the roster argument must unparse to self.packs) for the slice widths no bounded roster can reach. Round 3's own battery found self.packs[:3] / [-3:] surviving all six behavioural runs — the structural pin is what closes them — and one row is recorded NOT CAUGHT: a reduction over a window twelve packs wide, which needs a 13-pack roster to observe. No shipped behaviour changed in this round; only what observes it.

  • Twelve source mutations, eleven red, one argued survivor, through tools/mutation_run.sh (bytecode purged). The battery also found a real weakness of its own: _flat_bms_floor() had the default in two places and each covered for the other, so deleting either survived — masking, in three lines of option reading. One defaulting line now.

  • ⚠️ FIX ROUND — that battery was INCOMPLETE, and the review found what it missed. Neither of the two mutations below appears in the twelve rows above: the ledger graded "the reduction dropped" and "the bare option handed over" and never asked what happens when the reduction is simply the wrong one, or when the roster handed to it is sliced. No shipped behaviour changed here; two checks whose data could not reach the failure they named did. max(floors) → min(floors) in binding_soc_floor() (zero byte delta) and self.packs → self.packs[:1] at the decide() call site (+4 bytes) were each green across all 19 files. Both survived for the same reason: under any rule-8-valid config every pack's pack_floor_pct() equals peak_soc_floor, so floors is a list of identical numbers and max, min, first and last are four spellings of one answer — and the one check using a cut-out above the EMS floor ran on a roster of ONE, where every reduction agrees. The second also walked through part 12g, which asserted "self.packs" in <the unparsed call site>: a slice still contains that substring, so the pin passed on the mutation that grades the whole site against pack A. MUTATION.md habit 4 — a source-text test is a check on how code is spelled, not on what it does.

    • New part 12c2 evaluates binding_soc_floor() on a roster whose per-pack floors all differ — four simulated cut-outs of 30/25/40/35 %, every one above peak_soc_floor, chosen so that max (40), min (25), first (30), last (35) and the mean (32.5) are five different numbers and the two extremes sit at interior roster positions. Two packs cannot separate those four; four is the smallest roster that can. The precondition is its own check (habit 1) and one pack — the last, neither deepest nor shallowest — is then raised past the old maximum and the answer follows it (habit 7).
    • Part 12g is now behaviour, not source text. Real Controller.cycle()s on a two-pack roster, both packs at the same SoC, with the cut-outs as the only thing varied: move the non-first pack's cut-out and the floor reaching decide() moves 20 % → 35 %, with the site's verdict flipping from a sized discharge to FLOOR-LIMITED. self.packs[:1] answers 20 % both times. Which option key the floor comes from stays pinned on the source where it already was, because that claim genuinely is about the code's shape.
    • ⚠️ Two MORE survivors, found by this round's own battery and recorded rather than quietly repaired. (a) The first cut of part 12g varied only pack B's cut-out, so self.packs[-1:] — grade the site against the last pack — agreed with the full roster on both runs and stayed green across all 19 files (+5 bytes). A two-run fixture pins one slice and not the other. Part 12g now runs the same pair of cut-outs in both orders, so the deeper one is on the second pack in one run and on the first in another and the site floor is 35 % in both; no single-position slice passes all three runs. (b) binding_soc_floor()'s empty-roster branch rewritten to return None (−43 bytes) was also green — a defensive branch nothing in the suite reached. Both directions of it are pinned now, with the note that it cannot permit anything either way because pack_floor_soc is None at an empty roster.
  • ⚠️ THIRD FIX ROUND — the same family was alive at the SIBLING ARGUMENT of the same call. Rounds 2 and 3 hardened the FLOOR axis; decide() is handed a second reduction over the same roster beside it, soc=self.pack_floor_soc, and peakguard.py's own docstring names the two as a pair. Three rewrites of Controller.pack_floor_soc were green across all 19 files on 52380c0 and again after the rebase onto 3934ad7: min(float(v) for v in vals) → vals[:2] (+4), vals[-2:] (+5) and vals[:3] (+4), while [:1], [-1:], [1:], [:-1], max() and the mean were all red. The suite's separating power on the SoC axis stopped at exactly N=2 — the state the floor axis was in before round 3. It changes a real answer: a three-pack roster at 50 / 60 / 11 % with the emptiest pack THIRD answers 11 % shipped and 50 % mutated, so the site is graded for discharge PERMISSION against a pack 39 points fuller than the emptiest and spends a pack its own BMS stops. Round 3's machinery transfers directly — new part 12i: six real cycle()s with the emptiest pack at every position of a three-pack roster and both positions of a two-pack one (the observable read off PeakDecision.soc, cut-outs held flat so the floor axis cannot be what moved the answers); computed slice and non-slice tables that go red naming any member nothing kills; a length sweep of 78 real rosters, lengths 1–12, closing head and tail windows of width 1–11 and recording width 12 as honestly unreached; a none-guard sweep over the same 78; and three exact structural pins — the vals comprehension must iterate the bare self.inverters, and both any() and min() must reduce the whole vals — which close every slice width at every roster length. No shipped behaviour changed; only what observes it.

  • ⚠️ SPIKE-04: production is DEGENERATE on the floor axis, so the differing-floor fixtures are the entire exposure. Pack B is 4 × Dyness DL5.0C, DoD 90 → floor 10 % — FROM THE DATASHEET AND THE SERIAL; inverter B does not exist and nothing about it is measured. Pack A is DoD 90 → 10 % as well, and that one is measured. Both packs therefore floor at the same value in the field, max(10, 10) is 10 whatever it reduces, and a differing floor exists only in the fixtures. That is the argument for keeping them, not for simplifying them: anyone who collapses A_PACK_FLOOR != B_PACK_FLOOR_SIM to one number deletes the only data this repository has that can see the reduction at all, and part 12c2's precondition check goes red if they do. The SoC axis has no such degeneracy — two batteries at the same state of charge is a coincidence, not a configuration — which is what makes pack_floor_soc the half of the pair that will be live from the day inverter B is wired up.

  • ⚠️ The FAMILY enumerated rather than the member closed, and it found four more survivors in code this card never touched. Every reduction over self.inverters / self.packs in Controller was found from the AST and mutated to a slice against the full suite. Eighteen were already graded (site_batt_w, site_rating_w, site_max_w, site_dev_bound, site_circulating_w, inputs_ok, units, Controller.packs, maint_unit, the maintenance-due minimum, the store-migration roster, validate_unit_ranges and the round-2/3 sites). Four were not, and three of them are SAFETY-30's, all any(i.sign_wd.tripped for i in self.inverters) — cycle()'s stale-input hold, publish()'s status vocabulary and status_payload()'s banner — each +4 bytes and green across all 19 files, for the reason every blocker on this card was invisible: the only fixture that reached them was a roster of ONE, where self.inverters[:1] IS self.inverters. The first has teeth: a latched unit must take the roster past that hold or its failsafe SET stops being re-filed the moment a poll is missed, which is main.py's own sentence for it. New test_watchdog.py part 8 grades all three with the latch at EACH position plus a no-latch counterfactual, and new part 12j pins all 26 roster comprehensions in Controller to iterating the roster whole — so a reduction added over a slice anywhere in the class is red on the line it is written, with no fixture required. Two rows are reported open rather than closed: _grade_store_migration()'s second disjunct (now red on 12j, and argued to be an equivalent mutant because a unit tripped at startup implies its namespaced key is set) and cycle()'s undeliverable-unit log line, where sorted(...)[:1] (+4 bytes) is still green — it truncates names in one event message; the refusal itself is a different expression and is graded, so the site still stops.

  • ⚠️ FOURTH FIX ROUND — the same family one MODULE over, and the pin widened until it discovers its own scope. Round 4 enumerated the family and closed it inside the Controller class; the review found four more survivors immediately, in validate.py, on a 19/19 green suite: min(caps) → min(caps[:1]) (+4) and → min(caps[-1:]) (+5) at :779, the caps comprehension over caps_ix[:1] (+4) at :778, and min(caps_ix[-1:], key=…) (+5) at :893. None is an equivalent mutant. With max_w: 5000 on inverter-a beside 2000 on inverter-b and sign_disagree_w: 3000, the shipped validator refuses — "the SAFETY-02 sign-disagreement watchdog can never fire" — and all four accept: the site starts with a watchdog reporting armed that cannot trip on pack B. Rule 5's own failure mode reached through rule 5; rule 6 loses its refusal the same way. No shipped behaviour changed by the pin; what changed is that a hand-written scope stopped being trusted.

    • test_peakguard.py part 12j now parses every .py under app/ — no module is named in the check — and finds the roster by transitive closure from one seed, the inverters option key: through returns, through lists accumulated in a loop over a roster (which is what caps, roster and problems are, and what round 4's rule could not express), through attributes and properties, and through call arguments, which is how it walks into peakguard, arbiter, allocator, circulation, maintenance and store without being told they exist. A slice of a roster stays a roster so a mutation cannot cut the taint; an index is one unit and does not. 183 reductions across 9 modules out of 23 files parsed — main.py 96, allocator.py 24, validate.py 19, arbiter.py 14, circulation.py 10, maintenance.py 10, peakguard.py 4, inverter.py 3, store.py 3.
    • The hand-written module list would have been wrong in BOTH directions. It named watchdog.py, which reduces over no roster at all — SAFETY-30's sign watchdogs are strictly per-unit — and omitted maintenance.py and store.py, which both do. A vacuous claim about one module and no claim about two others.
    • The pin rediscovers all four blockers without being told where to look, and finds a fifth beside them (validate.py:783, rule 5's message) that no review round named. Its counterfactual runs at two depths: every enumerated site's own expression mutated with each of the four cuts this card has been defeated by (732 spellings, all reported), and [:1] written into app/validate.py at each blocker position with the whole analysis re-run over the mutated source — a sliced site required at that exact line, where the clean package reports none.
    • And the behavioural half, because a shape pin grades an identity and never a meaning. test_validate.py grows a roster SET for the three rules that reduce over unit_caps_indexed() — widths 2, 3, 4, 5 with the one small cap at every position, 42 runs of the real validator — plus a computed family table of twelve candidate reductions each compared with what the shipped validator actually said on the same roster. Only min agrees everywhere; a member no roster kills is printed as a named survivor.
    • ⚠️ A THIRD RULE WAS READING THE FLAT max_w, AND IT IS SAFETY-30's — found by reading, not by the pin, which is the shape of what the pin cannot see. unit_sign_disagree_w was graded against _number(opts, "max_w", 2000.0) three lines under a branch that had already stopped doing that. Both directions were measured: two 2000 W units beside a leftover max_w: 5000 and unit_sign_disagree_w: 3000 produced zero problems — the site started with a per-unit watchdog that could not trip on either unit — and two 5000 W units with no flat key were refused against a 2000 W default the operator never wrote. It takes the weakest unit's own cap now and names that unit; at a roster of one it is the same comparison, boundary and sentence it always was.
    • ⚠️ What the pin cannot see, with sizes, in DECISIONS/SAFETY-32-per-pack-bms-floor.md §4d: semantics (min vs max is a zero-byte edit); direct index sites that are not reductions; a subscript by a variable (weights[u] is why); a slice through an intermediate call; anything outside app/, including sim/inject.py; and the taint's own seam at *args and unresolvable receivers, where everything downstream goes unenumerated rather than reported unreachable. cycle()'s undeliverable-unit log line is still green at +4 bytes and still filed open, unchanged from round 4.
    • tools/supervisor_shape_probe.py re-run again (2026-09-05, 2026.08.0). The rebase onto 67e649a merged SPIKE-04a's max_w: 4600 into the same §C/§D blocks this card had rewritten, and a transcript stitched by hand out of two runs is not a measurement. all cases passed, exit 0, with B's rating reading 4600 — its datasheet figure, still not a measurement of any unit.
    • ⚠️ THE SWEEP, AND THE NUMBER THAT MUST NOT BE QUOTED ALONE. All 183 sites mutated to [:1], one at a time, against the full 19-file suite in goodwe-addon-ci (:ro, -B, fresh rsync per mutant, 0 .pyc before and after): 183/183 RED — which is tautological on its own, because the pin makes every slice red. The 51 whose first red was test_peakguard.py were re-run with the pin neutralised: 145 of 183 have a behavioural fixture that separates them from a slice of themselves; 38 have only the structural claim. All 38 are listed by site, with what a [:1] there would cost, in §4d and in test_peakguard.py part 12j — 15 of them are rows and counts on the operator's page, 3 are len(targets) arithmetic beside a write path that IS graded, 6 are allocator internals ALLOC-01's fixtures reach but not with enough units to separate. None of the 38 is closed behaviourally by this card, and none is counted as covered.

⚠️ No measurement of inverter B appears anywhere in this change. It does not exist yet. Every second-pack figure — in fixtures, in the probe, in config.yaml's commented example — is simulated and labelled; only inverter A's 10 % is read off hardware.

At two inverters the sign watchdog stops comparing one unit against the whole site meter, and becomes two checks instead of one (SAFETY-30). disagrees(commanded_w, grid_w, ...) compared the command this controller put on ONE actuator against what the whole site is exchanging with the network. At a roster of one those are two views of the same thing - §6.2's identity - and that is what makes the check sound and what earned it the best record in the safety table. At two they are not, and it fails in both directions: inverter A commanded −1500 W while the meter reads +1500 W is evidence of nothing when inverter B is discharging 3000 W exactly as told, and - worse - a unit genuinely driving the wrong way is MASKED by a sibling that covers for it, because the site figure nets. No threshold recovers that; the summation destroys the evidence.

  • PER UNIT: each inverter's own share against its OWN measured power (Inverter.batt, holding register 0x0518, per-instance since DEV-02). Conclusion: the actuator I am driving is not doing what I told it - evidence about one device, so the remedy stays the per-unit failsafe SET that arbiter.CLAIM_SCOPE has classified SCOPE_UNIT since it was written. That entry read "the evidence is site-wide and the remedy is not"; after this card the first half is simply true. Verified by making one unit reverse while its sibling covers it at the meter: the shipped comparison is false on 0 of 14 cycles while the new one convicts that unit on every one, and only that unit is parked.
  • SITE: the SUM of the standing commands against the meter, as a new sign_site SET at P_SAFETY on the site actuator, latched under flat site_sign_tripped / site_sign_reason. This is the fault the 2026-08-20 capture contains and no per-unit check can see it, because every inverter is faithfully executing its share - what is wrong is the number they were given. It stops every inverter and the banner names the site rather than an inverter, so nobody is sent to swap the wrong box.
  • ⚠️ Different questions from SAFETY-31, and the PR and the decision record both say which. circulation.py compares the units against each other and catches two inverters pushing through each other, which nets to zero at the meter and which no single command is evidence about. This compares each unit against its own command. They overlap in exactly one scenario - a unit reversing while its sibling pulls the other way - and test_watchdog.py asserts on that fixture that both fire and what each concludes. It is also not the saturation freeze: that is a magnitude test (|command − measured| > 500 W) that shapes the loop and fires on a merely saturated unit; this is a direction test that latches and parks one.
  • ⚠️ All four thresholds RE-DERIVED at two inverters - one carried with a justification, one refused. 1890 closed-loop runs in which nothing is faulty, over the whole range config.yaml accepts for gain and slew_w, across load reversals with write staggers and flapping loads, run at both rosters so the N=1 arm is the control. unit_sign_disagree_w: 250 is saturation_w / 2, so the smallest divergence this can see is exactly the gap at which the control law itself already says the inverter is not following; unit_sign_disagree_s: 85 is 8.5× the worst legitimate opposition those runs produce (10.0 s), 2.8× the firmware's own 30 s link veto and under half the site hold. site_sign_disagree_w: 300 is carried - its argument is the meter's noise floor and the deadband, and the roster touches neither. site_sign_disagree_s is NOT: 180 s would have shipped a false trip. The worst legitimate crossing at 300 W is 110 s with one inverter and 215 s with two, because the command must travel a rail that is the roster sum at a slew_w that is not - reachable at gain: 0.05, slew_w: 50 and a 2.2 kW load reversal, all schema-legal. 325 s is 1.51× that, inside the 900 s billing quarter and inside every episode of the fault day. See DECISIONS/SAFETY-30-per-unit-sign.md.
  • ⚠️ At ONE inverter this changes nothing, and "nothing" is asserted rather than assumed. The two questions are the same sentence at a roster of one, so only the detector that shipped is armed: same comparison against the meter, same 300 W / 180 s, same reason string byte for byte, same namespaced latch and flat rollback mirror, same failsafe claim, same banner, same single status row - and the site detector's window is never so much as opened. unit_sign_disagree_* and site_sign_disagree_* do nothing on a one-inverter install.
  • The threshold WIRING is pinned, not just the threshold values. Review found that arm(self.sign_cfg if one else self.unit_sign_cfg, ...) could be collapsed to arm(self.sign_cfg, ...) — arming every unit with the meter-facing pair instead of the re-derived per-unit one — with all 19 test files still green, because nothing at a roster of two read sign_wd.cfg and the trips in the fixture happen under either pair. test_watchdog.py part 3 now asserts the pair and the instrument on every detector against literals, and the fixture's three threshold pairs were made pairwise distinct in both coordinates so that a hold delivered from the wrong pair cannot compare equal to the right one. M14–M16 in DECISIONS/SAFETY-30-per-unit-sign.md §5.
  • Known and recorded rather than fixed: the site comparison is defeated by a square-wave load whose half period is about one control cycle, which holds it opposed for ~1000 s at both rosters. The N=1 control arm is what says this is a property of comparing a lagged command against a meter and has nothing to do with the second inverter, so it is not acted on here - it wants an alternation test, not a number, and a card of its own.

An operator can declare a second inverter, and the shape was measured against the Supervisor rather than assumed (CFG-04). DEV-02 made rating, SoC, watchdogs, heartbeat and store keys per-instance, so the code no longer assumed one inverter — but the options schema still described exactly one, and build_roster() returned a list of length one and said so in its own docstring. The roster could only ever be a roster of one. Version bumped to 0.6.0, because the Supervisor keys the built image by version: and a schema change without a bump is a schema nobody reads.

  • inverters: — a list of objects, defaulting to []. Empty is not "unconfigured", it is the single-inverter configuration: the flat setpoint_entity / soc_entity / batt_entity / batt_invert / max_w keys describe the one unit exactly as they always did. An install that upgrades reads identically — same entities, same rating, same behaviour, no operator action, and the whole existing check suite runs against it unchanged.
  • ⚠️ The shape was ESTABLISHED, not assumed, and the empty default is the load-bearing part. There was no list-of-objects anywhere in config.yaml and static_profile carries its structure as a JSON string in a str? precisely because a nested schema was doubted. So Supervisor 2026.08.0's own AppOptions validator — the version this site runs — was run against this repository's config.yaml out of the release image (tools/supervisor_shape_probe.py, committed; the transcript and the reasoning are in DECISIONS/CFG-04-inverter-roster.md). It accepts the list, enforces per-entry types, refuses a missing name / setpoint_entity / max_w by name, and renders the option in the UI as a repeatable section. And the shipped options: block validates as it stands while the same block with only inverters removed is answered with Missing option 'inverters' in root — one key varied, so the refusal is about that key — which is every options blob written before this version, since the key did not exist when they were written. App.options is the shipped options: block deep-merged with the operator's stored one, so inverters: [] in config.yaml is the difference between an upgrade nobody notices and an add-on that cannot start with a schema pinned to the version that would fix it. That is docs/deploy-rollback.md §4's trap in the forward direction, found before it was sprung rather than after.
  • Nothing is inherited by an entry that omits a key, and that is DEV-02 restated as a config rule. name, setpoint_entity and max_w are required of every entry; a missing soc_entity means this unit has no SoC sensor, never use the other one's. A three-line fallback to the flat keys would have rebuilt the sibling-grading defect DEV-02 spent a card removing, in YAML. Defaults still live in exactly one place (CFG-03): there is no per-entry default anywhere, because there is no optional per-entry number.
  • SAFETY-28's actuator_writers() refuses two inverters naming one setpoint_entity — the first configuration in this add-on's life in which that was expressible. The census was already structural and case-folding, so it needed no change; what it needed was a config that could express the hazard, and now there is one. Its sibling refusal is new: a flat setpoint_entity left set beside a declared roster names an actuator nothing will write, and is refused rather than ignored.
  • ⚠️ Two PERMISSIVE READERS in shipped code, found and fixed. Both failed in the direction that hides a defect. (1) validate.py rules 5 and 6 compared sign_disagree_w and maintenance_charge_w against the flat max_w; at a roster of two 2000 W units with max_w: 5000 left over from a single-inverter install, sign_disagree_w: 3000 passed rule 5 while SAFETY-02's watchdog could fire on neither unit — rule 5's own failure mode, reached through rule 5. They now read the roster's caps (unit_caps()), which at one inverter is [max_w] exactly. (2) run_control() re-ran the device-rating check behind if self.o.get("setpoint_entity") — the flat key, which a roster config leaves blank — so on a two-inverter site no inverter's max_w was ever graded against the device it is written to. validate_unit_ranges() grades each unit against its own ESPHome and runs unconditionally.
  • ⚠️ Three config.yaml READERS IN THE CHECKS took the first match on a stripped line, and one of them was already known. test_peakguard.py's read_option() and _schema_bound() and test_inverter.py's read_schema_max() threw indentation away, so the nested per-inverter max_w: began outranking the flat one — silently, and correctly, because the two bounds are the same int(100,5000) today. A reader that is right by coincidence is the failure mode this project is named after. All three are anchored at exactly two spaces now, the halves of the file disambiguate peak_cap_w instead of first-match, and an ambiguous key raises rather than picking one. test_tariff.py's copy of the idiom went with them.
  • The audit is a check, not a promise. test_inverter.py part 11 finds every config.yaml-reading function in the suite — transitively, so a reader that never names the file because it delegates is still found — executes each one against a synthetic two-inverter config.yaml whose per-inverter numbers differ from its flat ones, and fails if any returns the per-inverter value. The table is not maintained by hand: the signature decides, so the eleventh reader is named on its first run. config.yaml declares inverters: before max_w: on purpose, and part 11 asserts that ordering, so the trap stays baited rather than sorted out by an ordering nobody would maintain.
  • Ten mutations run and observed red (tools/mutation_run.sh), listed in test_inverter.py part 12 with the check that bites each. Two survived the first run and the checks were changed, not the table: the inheritance check had blank flat keys, so "inherited" and "not inherited" were the same empty string; and the run_control() check asserted a source line was present, which re-indenting it does not remove. The second is now driven through the shipped run_control() under a deadline, because that mutation's real symptom is a hang rather than a red.

Circulating power - two inverters pushing against each other - becomes a measured quantity, a bounded one, and an alarm that survives a restart (SAFETY-31). Inverter A charging at 3 kW while inverter B discharges at 3 kW nets ~0 W at P1: the site reads idle while the packs are cycled through two round-trip conversion losses continuously. Every guard in this add-on is a consumer of that net figure, so none of them can see it - SAFETY-02's sign watchdog gates on abs(grid_w) > 300 and the gate never opens, and both the peak guard and the capacity tariff bill grid exchange.

  • A site sensor, Σ|Bᵢ| − |ΣBᵢ|. Zero when the units pull the same way, 2 × min(|B_a|,|B_b|) when they oppose. Published as sensor.goodwe_circulating_power beside the grid figure, because "grid 0 W, circulating 6000 W" is the whole phenomenon in two dashboard rows and no arithmetic on the grid figure alone can produce the second one.
  • ⚠️ Derived from MEASURED per-inverter power, never from the allocation record, and that is the whole card. ALLOC-01's sign-coherence gate (REFUSE_SIGN, its AC 7) already refuses any allocation whose shares carry two signs, so a record-derived sensor reads zero by construction and could only ever confirm that the allocator agrees with itself. What this detects is circulation nobody commanded: a unit ignoring or lagging its share, a stale share still being executed, a maintenance or SAFETY-25 pin holding one unit while the loop drives the other, or HW-01's power stage running its last instruction for 6 h 25 m with the comms dead and the allocation record impeccable throughout. Verified by making one unit ignore its share on the TEST-19 rig: the record stays ok with both shares at −1250 W - a record-derived sensor reads 0 W - while the shipped sensor reads 2000 W. Inverter.batt became per-instance in DEV-02; before that this sensor could not have been written.
  • The trip stops the site, and the decision record says why that is an action rather than theatre. Sustained opposition files Claim.set("circulation", P_SAFETY, 0.0) on the site actuator - every inverter to 0 W, latched. HW-01 established that a wedged inverter cannot be commanded at all, so the remedy is not aimed at it: a circulating loop needs two participants and one of them is this controller, faithfully driving the listening sibling into the one that stopped listening. Stopping halves the loop, and - the more important half - makes the residue visible at the meter, where every existing guard can finally see it. What it cannot do is stop the wedged unit; the notification says so, and names the isolator as the last actuator.
  • The threshold and the window were measured, not chosen (AC 3). 924 closed-loop runs on the TEST-19 two-master rig in which nothing is faulty, swept over the whole range the schema accepts for gain and slew_w. Worst continuous legitimate opposition by threshold: 505.0 s at 100 W, 40.0 s at 250 W, 10.0 s at 300 W, 5.0 s at 400 W and above. The knee is 400 W and it is the schema floor. circulation_w: 700 is 1.75× it, the headroom bought for inverter B's ramp and lag being placeholders until SPIKE-04 measures them. circulation_hold_s: 75 clears three bounds - 15× the worst legitimate episode (5.0 s), 2.5× the firmware's own LINK_STALE_S veto, and 12× inside the 900 s capacity-tariff quarter. A momentary opposition while one inverter slews through zero is legitimate - the serialised write path lands B's number up to a control cycle after A's - and the guard does not fire on it, in any of the 924 runs.
  • The alarm survives a Home Assistant restart (SAFETY-34). persistent_notification is in memory, which is exactly how the 2026-09-02 outage went unseen for 6 h 25 m with the detector correct throughout. The latch is persisted to /data as flat, site-level keys - flat because the quantity is defined over the roster and is identically zero for any one unit, so there is no inverter to attribute it to - and the notification is re-raised on the first cycle after every start, through the same code path as a fresh trip.
  • At one inverter the sensor is identically zero and nothing changes (AC 5). |B| − |B| == 0 for every reading, including one nobody took; no claim is ever filed, the arbitration is byte-identical, and the status page says n/a rather than claiming to watch something that cannot happen.
  • Verified by breaking it. 18 mutations against the sensor, the window, the latch, the claim, the store, the alarm, the routing table and both config copies - all red, each on a named check; one equivalent mutant argued rather than claimed; and one genuine survivor found and closed (publish() turning an unknown into a published 0 W). arbiter.CLAIM_SCOPE gains its ninth source and test_peakguard.py's 10f/10g tripwires were updated deliberately, as their own comments require. Full ledger in DECISIONS/SAFETY-31-circulating-power.md.

Every per-device value stops being a Controller scalar: rating, SoC, battery power, watchdogs, heartbeat, write bookkeeping and store keys are now per-instance (DEV-02). app/inverter.py introduces an Inverter object that owns its entities, its rating, its device range, its SignWatchdog, its last_write and its last_beat, under store keys namespaced by unit name. The Controller holds a list of them and keeps only what is genuinely site-level: the P1 reading, the site integrator, and the tariff quarter.

  • What the scalars were silently asserting. One dev_min/dev_max pair was read from one setpoint_entity, so a second inverter's rating was never read at all and its clamp, its freeze rail and the peak guard's achievable_w were the first one's numbers. One soc fed the maintenance FSM, SAFETY-24's pack floor and arbitrage's bounds. One SignWatchdog - whose own docstring says "one instance per actuator" - latched under flat store keys, so a trip caused by B latched A across restarts and one operator press cleared both. One last_beat and one serialised hass.call() meant a hung write to A ate B's 30 s layer-1 budget.
  • actual_w became SITE level while the readings became per-instance, and those are opposite directions on purpose. compute()'s anti-windup test is abs(prev_w - actual_w) > saturation_w with prev_w the site target, so feeding it one inverter's power compares a site number against a unit number, trips the saturation freeze permanently and leaves a standing grid error. Measured on admin/goodwe's two-master rig, 2 kW load: with one unit's power the aggregate trace at the meter is split-dependent by 510 W at gain: 0.2, 250 W at 0.4 and 50 W at 0.6; with the site sum every split is bit-identical at every gain the schema accepts. That was ALLOC-01's disclosed finding, graded in test_alloc.py part 8 and now closed there.
  • The store migration is graded, not merely performed. sign_tripped / sign_reason move to unit/<name>/... once, verified by reading back what was written, and the version marker is only set when nothing that carried state was lost. The flat keys are left in the file so a rollback still finds its latch. And Controller.__init__ compares the pre-migration flat latch against what unit A actually came up with: if the latch did not survive it is re-armed from the legacy value and shouted about, because a latch that silently fails to migrate is a disarmed safety guard on an install whose state file says it is protected.
  • Heartbeats are independent, and the budget is derived. Each inverter owns its own deadline, the refreshes are dispatched concurrently, and each write is bounded by WRITE_BUDGET_S (4 s). The inequality that fixes that number is graded rather than asserted: 4 + heartbeat_s's schema maximum of 25 < 30, layer 1's FIRMWARE_INGEST_VETO_S. Verified by injecting a transport that accepts and never answers: B's write reaches the wire while A is still hanging, and the serialised shape it replaces is run beside it.
  • live_units() answers honestly. A unit whose every write has been rejected for a whole layer-1 window is not commandable; the allocator drops it, the survivors carry its share, the action log names it, and the dropped unit is commanded 0 W rather than left standing on its last share. A roster entry with no setpoint_entity is deliberately not handled there - that is a configuration that cannot be delivered, and it reaches main.py's refusal branch, which commands 0 W and names the inverter.
  • At N=1 nothing moves. The removed scalars survive as read/write properties of the sole inverter, so every existing replay in this repository runs unmodified - and they refuse at N>=2 rather than answering for the first inverter, which is the tripwire on a consumer that was never made per-instance. test_inverter.py is the new file (77 checks); test_alloc.py part 8, test_peakguard.py 10g/10h, test_watchdog.py and test_clamp.py were re-aimed rather than relaxed.
  • Inverter B still does not exist. build_roster() returns exactly one inverter, from the flat options, and is the one function CFG-04 changes. Every two-unit figure above is architecture, not a measurement of a second device; the second rating in the checks is marked as a hypothesis.

The write path is gated on the allocation record, not on how many config keys exist (SAFETY-28). specs §1.5 makes "any configuration in which two writers can reach one actuator" a non-goal. Until now that non-goal was enforced by len(validate.ACTUATOR_WRITE_KEYS) == 1 - there is exactly one option key, so a second writer is not expressible in the schema. True, and a statement about the shape of the options schema rather than about the writes: add a per-inverter config (CFG-04) and there are two real writers with that length still 1, so the check stays green while the property it protects is gone. sim/inject.py's two_writers scenario asserted on the same tuple and went green with it.

  • The enforcement moved onto the writes. write_setpoint() now refuses any value that is not in this tick's allocation record from ALLOC-01: Controller.write_refusal() asks Allocation.authorises() whether the single allocator placed exactly this number, for this unit, on this tick. A second writer with arithmetic of its own cannot satisfy that - its number appears in no record - so it has to file a Claim and go through resolve(), which is the one allocator. "Exactly one allocator per shared resource" stops being a convention and becomes something the write path checks.
  • A refusal is a refusal, not a log line. The unauthorised value is replaced with 0 W and written. Returning instead would leave the inverter latched on its last command with the ESP32 heartbeat still being fed - holding an unauthorised setpoint quietly, which is the outcome the gate exists to prevent.
  • A stale record cannot be replayed. Every record now carries the tick it was made for, handed in by the caller so allocator.plan() stays the pure function test_alloc.py part 10 grades. The counter advances once per resolution, not once per loop iteration: a new allocation makes the previous record stale immediately, while the "inputs missing, not yet stale" hold - which returns before the allocator runs, so one dropped meter reading does not zero the inverter - leaves the standing authorisation intact for the heartbeat. An unstamped record authorises nothing; "I cannot say when I was made" fails closed.
  • ⚠️ 0 W IS AUTHORISED UNCONDITIONALLY, SO THE FAILSAFE CANNOT DEADLOCK BEHIND THE GATE. write_setpoint() is also how layer 2 commands zero, and every path that does so - cycle()'s two refusal branches, shutdown(), the operator's stop button - runs while the allocator has refused. A gate that asked the allocator's permission to command zero would block the safety write behind the very component whose failure the safety write answers. The exemption is on the value, not on a failsafe=True flag a caller asserts, and the argument is that the hazard §1.5 names is N-times loop gain from broadcast: at S = 0 the broadcast and the correct allocation coincide - a_i = 1 for every unit gives every unit 0 W, which is exactly its share - so there is no over-command to make at zero. Driven end to end through the real refusal branch in test_clamp.py part 7c.
  • unmet_w is still not ok. The gate reads ok and the unit's share and never unmet_w, because an allocation that could not place every watt is still safe to write; fusing them would let one saturated inverter park the whole site. Graded on a record with 3800 W unmet.
  • ACTUATOR_WRITE_KEYS is replaced by actuator_writers(), which counts writers per actuator rather than option keys, and finds them by walking the options tree rather than by looking for a container name CFG-04 has not chosen yet. Two inverters with two entities are accepted - that is what the per-inverter roster is for; two declarations aimed at one entity are refused, naming the actuator and every writer pointed at it. The tuple survives only as the enumeration a census needs, and nothing asserts on its length any more.
  • What neither check observes, said out loud. The census sees configured writers, so a second write path added in code is invisible to it - exactly as it was invisible to the tuple. That half is closed at runtime by the record gate, which does not care what the options look like or who called the method.
  • Verified by breaking it: seven mutations on a purged tree via tools/mutation_run.sh - removing the gate, making the zero exit an amnesty, dropping the tick comparison, deleting the census refusal, fusing unmet_w into ok, freezing the tick on the live path, and moving the gate below the clamp - each turn test_clamp.py or test_validate.py red.

The site grid target is now ALLOCATED across N inverters, sum-invariant, and never broadcast (ALLOC-01). ARB-03 left allocate() as a documented seam that passed through at N<=1 and DECLINED at N>=2; this fills it. The new app/allocator.py turns one site target S into per-inverter shares with one invariant - sum(shares) + unmet_w == S, in integer arithmetic - and each inverter is then told a function of its own share, never of the shared measurement.

  • Why a broadcast is a fault and not merely an inefficiency. The control primitive is meter emulation: the master reports a fabricated grid reading and the inverter regulates itself to it, so one number means "the battery moves X W" here and "the grid is at X W" there - an identity that holds only at N=1. Hand both inverters the same target and each supplies it in full, so the loop gain at the meter becomes N times the per-unit gain. Measured on admin/goodwe's two-master rig (TEST-19): -400 W export overshoot at gain: 0.6, and at gain: 1.0 - which config.yaml accepts as its documented maximum - a permanent 4000 W peak-to-peak limit cycle with not one guard firing. The sign watchdog is evaluated on every cycle and never trips, because the disagreement flips on alternate ticks and never holds its 180 s window.
  • The stability property is structural, not tuned. With sum(a_i) = 1 the gain at the meter is sum(a_i * g_i), a convex combination of the per-unit gains, so it lies in [min g_i, max g_i] for any split. That is what makes the weights a comfort choice (SoC, thermals, wear) rather than a tuning parameter, and it means a bad split cannot destabilise the site. Graded directly in test_alloc.py part 9, and measured end-to-end: a 90/10, a 50/50 and a 100/0 split produce a bit-identical aggregate trace at the meter, and a gain sweep to 1.0 at every split shows a flat tail at all 84 combinations.
  • Rounding is a safety property here. The register is 1 W, and a per-unit round() biases the sum - measured at -125 W over 50 000 ticks at three inverters. At 1-2 Hz that is a permanent standing error the site integrator chases and never reaches. So the target is rounded once, at the top, and the fractional parts are settled by largest remainder with a deterministic tie-break; every sum below that line is integer arithmetic and cannot drift. Verified over 250 000 randomised ticks: 0 sum failures, 0 envelope escapes, and the one rounding that is left - the single site-level quantisation_w, never distributed into a per-unit bias - totals -39.8 W over 137 964 allocations, i.e. -0.0003 W per tick.
  • Each share is clipped to that unit's interval, and THE TWO ENDS OF THE INTERVAL ARE APPLIED INDEPENDENTLY. UnitBounds() defaults to (-inf, +inf), so a one-sided envelope is the ordinary case at N>=2 rather than an edge. The first cut of this work folded both ends into one min(max(v, lo), hi) and substituted v itself for a missing bound, which reads as "an absent bound cannot bind" but is not what it does: with hi == inf the expression collapses to min(max(v, lo), v) == v, so a missing ceiling silently discarded the floor. _clamp_int(0, 2142, inf) returned 0. The worked failure it caused: a unit with a 2000 W floor and no ceiling, beside a symmetric unit, against a +1000 W site target, was allocated +500 W - a quarter of its own floor - and the sign-coherence refusal that the same case with a finite ceiling correctly raises was suppressed with it. Fixed by clamping each end on its own, and UnitPlan.explain() can no longer print a share as being inside an interval that excludes it: that line now reads OUTSIDE ... - ENVELOPE VIOLATED, DO NOT WRITE.
  • The envelope is read per tick, never cached. plan() is a pure function of that tick's intervals and holds no state, because a unit's range moves for reasons unrelated to the allocator - a stale link, a pack at its floor, a device rating that failed to read.
  • A dead link is announced, not absorbed. A unit whose master is stale is dropped from the envelope set; the survivors carry its share, and the allocation record names the unit and the reason so main.py logs it. A site running at half its inverters and reporting nothing reads as healthy on every dashboard.
  • Opposite directions are refused, not averaged. One pack discharging while another charges nets to exactly the right number at the meter, so no existing guard can see it. A sign-coherence gate makes it inexpressible.
  • scope_violations() is now consumed, and it is consumed as a refusal. ARB-03 left it logging without changing the resolution. A mis-routed claim means the number about to be divided may itself be wrong, and dividing a number that may be wrong is worse than not dividing it - the same answer clause 3 already gives a contradiction. It is not promoted into an envelope: a unit-scoped claim that landed on the site names no unit, so promoting it would mean guessing one.
  • At N<=1 it is a pass-through, byte-identical. The share is the site target, as a float, unrounded and unclamped. Every one of the existing suites replays unedited and green.
  • main.py still refuses to act at N>=2, for a new and narrower reason. There is one setpoint_entity, so this controller can command one inverter; a valid two-way split names an inverter it has no writer for, and commanding a partial site is a worse instruction than commanding nothing. The old "no allocator" refusal and its test (test_peakguard.py part 10h) were re-aimed, not deleted - allocated=False is now reachable on a mis-routed claim, an empty envelope set, or sign incoherence, and all three are graded on real cycles.
  • And the replay that missed it was widened, so the fix is graded rather than merely applied. The 250 000-tick replay drew every envelope as B(-uniform(0, rating), uniform(0, rating)) - finite on both ends and containing zero, every time - while the check it fed claimed "no share ever leaves the envelope it was clamped into". The data could only exercise a symmetric closed interval around zero, so it reported 0 escapes against a live defect. The generator now draws from every shape UnitBounds can express: half-open above, half-open below, intervals that exclude zero, and bare UnitBounds(). Measured A/B against the defective clamp on the same seed and the same 250 000 ticks: the old generator sees 0 escapes, the new one sees 39 991. Reverting the clamp fix under the widened generator takes test_alloc.py red on four checks; re-applying it takes it green. The collapse is now a row in part 12's mutation table.
  • Known and not closed here: at a roster of two the loop's actual_w is one inverter's power used as a site measurement, because the add-on binds a single inverter_power sensor. That is the sensing half of the same N=1 identity this card removes from the commanding half, and it makes the aggregate trace split-dependent below gain: 1.0. Measured, with the counterfactual, in test_alloc.py part 8 and tools/alloc_sim.py --splits. It belongs to DEV-02.

Claim carries the actuator specs.md always said it did, and resolve() is three-stage (ARB-03). specs.md §6.1 declares actuator: str as the first field of Claim; the shipped app/arbiter.py had no such field, so every claim was implicitly about "the one and only actuator", resolve() returned one scalar, and main.py assigned it to one self.target. There was no seam an allocator could occupy - and ARCH-01 decided the site grid target is ALLOCATED across several inverters and never broadcast. This is a regression fix against the written design, and it creates that seam. At N=1 it is a pure refactor: every one of the 17 suites replays unedited and green, on the same numbers.

  • The split, verified at each construction site rather than assumed. Four sources are about the grid connection and are SITE claims - loop (regulates grid_w, the P1 measurement), peak (the quarter-hour average offtake the capacity tariff bills), arbitrage (buys and sells at the grid against a day-ahead price) and safety (stopped is the site's switch, inputs missing is the site's own meter). Four are about a pack, a device or one write and are PER-INVERTER - device (one inverter's own reported rating), supervised (max_w caps what may be WRITTEN to one setpoint entity), failsafe (site-wide evidence, per-unit remedy: SAFETY-02 grades the command THIS controller put on THIS actuator, and at N>=2 that evidence cannot be pinned on a sibling nobody here commands) and maintenance (§12's recalibration is a pack procedure). The reasoning is recorded at the line, in arbiter.CLAIM_SCOPE and again at each claims.append in main.py.
  • Getting it wrong is the parked-battery bug, so it is routed rather than written. A per-inverter reserve filed as a site hi against the peak guard's site lo is lo > hi, arbiter clause 3, 0 W in the billed quarter - SAFETY-25 §0a's fatal case. actuator_for() is the one routing point and it raises KeyError on an unclassified source rather than defaulting to the site, because defaulting to the site is the failure itself.
  • Three stages, each a function a test can construct a case at. pre_resolve() turns one inverter's own claims into that unit's interval; site_resolve() turns the site claims into one grid target and is the shipped arbiter, unchanged; allocate() is the seam, and deliberately not an allocator - ALLOC-01 builds it. With at most one unit it passes the target through (§6.2's N=1 identity); with two or more it declines, no shares, allocated=False, because the obvious placeholder - hand the target to each - IS the fault ARCH-01 was filed about. What main.py then does is SUBSTITUTE, not abstain: it replaces the resolution with a 0 W failsafe, logs "refusing to broadcast the site target", and writes that 0 W through write_setpoint() like any other cycle. The refusal is to BROADCAST; the write still happens, in the fail-toward-inaction direction. Graded end to end on a real two-inverter cycle by new part 10h - the branch is unreachable on the shipped roster, and replacing it with if False: had left all 17 suites green.
  • resolve() HONOURS the roster it is handed, and that is now graded too. Left None the roster is derived from the claims, which is the documented default; passed explicitly it is used. Deriving it always - ignoring the argument - makes a unit that filed nothing this cycle cease to exist, so a site of two reads as a site of one and the seam passes the whole grid target through to the inverter that spoke: ARCH-01's fault with its own evidence removed. test_arbiter.py part 7 grades it on the one case that separates the two, a silent unit.
  • The contradiction is no longer guarded against, it CANNOT BE WRITTEN DOWN. The partition is by actuator and it is a partition: a unit's hi and the site's lo are never both terms of one lo > hi test. Constructed and swept - 40 filings (every per-inverter source x unit x bound, a unit contradicting ITSELF included) against a live site floor, and not one moves the site target or raises a contradiction. A unit's own impossible pair parks that unit and says so on its own bounds; it does not park the site. That is SAFETY-25 §0c's table made mechanical.
  • At N=1 nothing splits, and that is §6.2's identity rather than the classification being ignored. With one inverter the fabricated grid reading and the battery setpoint are the same number, so the grid connection and the only unit ARE one actuator and every source routes to the site. Measured: dropping that identity - splitting at N=1 - takes test_peakguard.py, test_freeze.py and part 10g red, because the failsafe and maintenance SET claims would stop competing for the winner, explain() would name a different source and loop_is_following() reads that name.
  • SAFETY-24's floor asymmetry survives, and now has a second half. The combination sweep is re-run and still holds - no negative floor, hi still +inf on every claim the guard files - and it now also asserts every one of them is on the site actuator, because a floor bound to one inverter's share would leave the site, the thing the capacity tariff meters, with no floor.
  • The part 10f tripwire is kept and widened, not adapted around. Its static AST scan and its dynamic SoC sweep are untouched in substance - source is still Claim.set()'s first positional argument precisely so the scan keeps reading it, which is why actuator is the LAST field of Claim and not the first. Its spy gained **kw so the roster passes through unread rather than being silently dropped. New part 10g pins CLAIM_SCOPE to the same eight-source set, so a ninth source now goes red twice. Verified by breaking it: building SAFETY-25's Option B as a ninth source still takes 10f red on the line it is written.
  • And the CALL SITES are pinned statically, at all eight of them. 10g's first cut graded routing only through a real two-inverter cycle and called that "the line a mis-typed actuator_of(...) at a call site goes red on". It was not. That cycle reaches device, supervised and loop and nothing else - three of the eight direct appends - so a mis-type at the other five survived every suite in this repository. Proved on the shipped tree by PR #40's reviewer: actuator_of("maintenance") -> actuator_of("peak") at the maintenance-shaping append left test_arbiter.py, test_peakguard.py and test_arbitrage.py all green while, at a roster of two, it built a site loop of -1500 W against the guard's site lo of 1500 W and the now-misrouted charge-only hi = 0 - lo > hi, arbiter clause 3, 0 W in the billed quarter, SAFETY-25 §0a's fatal case from a one-word typo. That is this repository's named failure mode - a check observing something other than what it claimed - reproduced inside the check written to prevent it, so it is closed the way 10f closes it: over the same AST scan. All eight direct appends expose their actuator as a literal actuator=self.actuator_of('...'), so the literal is required to EQUAL the source the claim is filed under - all eight, on the line the typo is written, in every configuration and at every roster, whether or not any fixture reaches the state that files them. Measured: each of the eight mutated to a wrong actuator in turn, each one red. The two INDIRECT appends (peak_claim, arb_claim) carry no actuator= at the call site to mis-type, and are pinned where their routing is actually chosen - peakguard.claim() by the SWEEP_SITE sweep, arbitrage.claim() by test_arbitrage.py. 10g's dynamic cycle is kept and now says which three of the eight it sees instead of claiming the class.

SAFETY-25's open question is ANSWERED: the BMS cut-out is the DELIBERATE and only backstop for demand-driven discharge, and a loop-side reserve floor is DEFERRED to ALLOC-01 rather than rejected (SAFETY-25). Decided by the product owner on 2026-09-02. Option A is the shipped behaviour, so app/ changed only where a comment claimed the question was still open - no setpoint, no claim, no option, no default moved, and the 17-suite run is green on the same numbers as before.

  • Why deferring is the safe direction, and it is a property of the shape rather than a preference. Option B's proof - bms_soc_floor < loop_soc_floor <= peak_soc_floor, verified through the real arbiter in test_peakguard.py part 10d - has an unstated premise: the reserve predicate and discharge_permitted() read the same state of charge. With two packs they read different numbers. The reserve binds on the emptier pack and files hi = 0 while the peak guard, reading the other pack or an average, files lo = excess > 0; lo > hi is arbiter clause 3 and the answer is 0 W, the battery parked in the billed quarter - the failure the memo itself marks fatal. No config-ordering validator can catch it, because it is a runtime divergence between two readings and not a config ordering, so CFG-01's shape of check would pass on the exact tree that parks the battery. Option A's cost is energy; Option B's cost built too early is a parked battery in the one quarter of the month that sets the bill.
  • The revisit trigger is recorded explicitly, and it is ALLOC-01. Under ARCH-01's host-side allocator the two claims stop sharing a list: the loop floor becomes a per-inverter hi consumed as an interval at stage A, while the peak floor stays a site lo at stage B. Different claim lists, different stages, structurally unable to cross - which is a stronger argument than the ordering rule, because it makes the crossing unreachable rather than harmless. That is the shape in which Option B becomes safe to build, and the memo says so at the point a future reader will look.
  • What will have to be RE-EARNED at N=2 is stated plainly rather than left for someone to discover. SAFETY-27 now names five floors across two packs, so "the SoC" stops being a scalar the config can bound. And test_peakguard.py part 10f - the pin that made SAFETY-25 mergeable - cannot express two packs: its dynamic half is a scalar 0-100 % SoC sweep against a single-series capture, and a two-pack exposure lives in the difference between two readings, which that sweep visits at no resolution. Its static half (the AST scan pinning the eight claim sources) still bites at N=2; the dynamic half goes silent. Merging a two-pack reserve on 10f's current green would be merging on a check that cannot see the failure.
  • The options analysis is kept intact on purpose. A memo that recorded the verdict and deleted the reasoning is the failure mode this DECISIONS/ directory exists to prevent, so §1-§7 stand exactly as written - including §5's "(recommended)" on Option B and §6's recommendation - with the new §0 saying what was decided and §6 marked as answered. Part 10e's check moved with the memo: it used to pin the honest Status: OPEN line and now pins that the memo names the option, the date and the trigger and still carries both options and the recommendation.
  • The tripwire stays, and "deferred" is why it stays. Part 10 and mutation 13 are unchanged in substance: a ninth claim source in Controller.cycle() still takes 10f red on the line it is written. Deferred, not rejected, is precisely the state in which someone builds Option B by accident.

Operator-facing surfaces follow the decision and nothing else changed on them: DOCS.md's SAFETY-25 section now says a choice was made and points at the trigger, and app/freeze.py's finding and app/peakguard.py's point 2 say "decided, on purpose" where they said "open".

PeakStore.record_block() now has its POLICY ARGUMENT graded, and the SAFETY-20 import check now looks at all three ways of writing an import (TEST-13). Two survivors from TARIFF-01's review, both closed in test_tariff.py only - app/ is untouched and no shipped behaviour changed.

  • The plumbing of the per-phase reduction was unobservable. Mutating record_block()'s billed_w(block, policy) to billed_w(block, POLICY_NET) left all 17 suites green (+4 B; recorded by TARIFF-01's reviewer, re-run through the purge harness for TEST-15, and re-run again here). The cause is the third instance of the same shape as WITNESS-02's span normalisation and TARIFF-01's own DST window: a stimulus evaluated where the quantity it grades is degenerate. billed_w() short-circuits to block.offtake_avg_w whenever per_phase_offtake_avg_w is absent, and every block that reached a store anywhere in the suite was single-phase or built with per_phase_offtake_avg_w=None - so NET, SUM and MAX collapsed onto one number and the argument could not be seen. Section 7 already owns an UNBALANCED fixture, (3000, 500, -200) W, whose three reductions are 3300 / 3500 / 3000 W; that block is now round-tripped through the store under each policy and read back from both tables. NET is the smallest of the three here, so a store that quietly billed NET while asked for MAX would under-record the month's peak - maximum headroom for SAFETY-07, the same under-guarding direction as the getattr(..., 0.0) default SAFETY-07 already removed from project().
  • The import half of the SAFETY-20 grader made a claim it did not check. It collected ImportFrom.module only, which is blind to two of Python's three import spellings: from . import arbiter as _ab is an ImportFrom whose .module is None (the module name is in .names), and import app.arbiter is an ast.Import node the walk never visited. Both were added to app/tariff.py and the shipped suite stayed green. Never a live exposure - the _names half still catches any USE of either alias - but the printed sentence "it imports nothing from arbiter, clamp or control" was false for two forms out of three, which is worse than claiming less. The grader now walks Import as well, joins from . import X onto its base, and matches per dotted SEGMENT so app.arbiter cannot hide behind a package prefix while clamps / arbiters / controller are not falsely flagged. Both graders are also now shown non-vacuous against main.py, which really does import all three modules.
  • Two items on the card were already closed and are struck, not re-implemented. PeakReading.is_observed is self.state == OBSERVED (app/tariff.py:266), already false for NO_RECORD; and project()'s held read is max(averager.held_net_w, 0.0) with no getattr default, fixed by SAFETY-07 in 616b62d with a comment naming TEST-13 item 4. Restoring a default there would re-open a money guard. Removing clear_partial() also stays green and that remains a PASS: the quarter_start PRIMARY KEY plus ON CONFLICT ... WHERE excluded > existing makes a replay a structural no-op, which is TARIFF-01's claim rather than a hole in it.

Verified through tools/mutation_run.sh (purge, python3 -B, tree re-read from disk, mutated line grepped off disk, byte delta recorded): 7 mutations, all red on the named checks, plus green baselines before and after and a control run showing the shipped suite passing every one of them.

The two arbitrage() rungs SAFETY-26's AC4 sweep found pinned from ONE SIDE ONLY are now pinned from both - and, the actual finding, are pinned so they stop MASKING EACH OTHER (TEST-16). spread == 0.0 weakened to <= 0.001 survived the whole suite at +2 B, and len(firm) < 2 weakened to < 1 survived at +0 B - the delta MUTATION.md names as the risky one. Neither was individually live, and that was the problem: a single firm hour also has a spread of zero, so each rung's failure was absorbed by the other and both could be weakened together with nothing reporting it. That is invisible to single-mutation testing, which is how the pair survived four rounds of review on TARIFF-03 and FCST-03. test_static_tariff.py gains section 9, which grades WHICH RUNG answered each stimulus rather than only whether it refused - the masked case refuses correctly while reporting the false sentence "the tariff is flat" about a series that is not flat, so a check asserting only "refused" passes on a broken tree. The flat rung is swept with small-but-REAL spreads down to 0.000001 EUR/kWh at min_spread_eur_kwh=0.0 (a value arbitrage()'s docstring documents and its validator accepts on purpose), the firm-pair rung is probed with a ONE-FIRM-HOUR series and graded on §8.3's sentence coming back rather than the flat rung's, and a five-row table denies the masking on both sides. Verified through TEST-15's tools/mutation_run.sh unchanged - recursive __pycache__ purge, python3 -B, tree re-copied from disk between rounds, mutated line grepped off disk, byte delta printed: 7 mutations plus a green baseline, 4 of them at +0 B, ALL RED, including both rungs weakened AT ONCE (5 checks red). No shipped behaviour changed - both rungs were correct all along; app/ is untouched. MUTATION.md gains a section on masking as a second way a survivor lies, and test_arbitrage.py's SAFETY-26 AC4 note is marked closed rather than left reading as an open finding.

check_output_clamp() could be moved above write_setpoint() in cycle() with test_clamp.py, test_freeze.py and test_loop.py all staying GREEN — the guard's write-path evidence, self.clamp_last, had nothing watching it. Measured before the fix, on the move itself: all three suites green. The guard has two evidence sources and only one of them was covered. self.loop_clamped is set from the Decision well above the write, so it survives the move — and on the §10.3 runaway replay it is the source of every engagement the alarm reports (0 write-path engagements against 2 loop-side ones), which is precisely what made the move nearly invisible. self.clamp_last is assigned by write_setpoint() and by nothing else (main.py), is None until it has run, and is what engaged_write reads; moved above the write, that consumer goes quietly false and a DEVICE-bound clamp — max_w above the inverter's own rating, SAFETY-20's install — stops being reported by anything. test_clamp.py gains part 6, and it grades the CONSEQUENCE rather than the position: a spy subclassed from the shipped ClampWatchdog records what self.clamp_last held each time the guard consulted it, over a slew-limited ramp where every cycle's command is a different number, and asserts the evidence is always the write of THAT cycle. Hooking clamp_wd.note() rather than the guard's name is what keeps a rename legitimate; the same assertions are re-run through a controller whose guard is renamed and whose write lives in a helper, and were verified against main.py itself — renaming the method throughout and moving both calls into a new _emit_and_guard() helper keeps part 6 green, while swapping the two calls turns it red on a line that names clamp_last. AC 3 needed a stimulus of its own: through the real cycle() the write-path half can never engage, because the arbiter files the device range and max_w as P_SAFETY LIMIT claims and resolution.target_w is already inside both bounds before write_setpoint() re-applies them — that duplication is deliberate defence in depth, and part 6 now measures the 0 engagements rather than leaving it as a claim in a comment. So the write path is driven directly at max_w 5000 against a ±2500 W device: the wire carries 2500 W, every loop-side flag stays clean, and the alarm fires on clamp_last alone — with the two calls swapped, the same stimulus clamps the same value and the alarm is silent. main.py gains one comment sentence pointing at the check, mirroring the one SAFETY-18's block already carries for test_freeze.py part 5.

max_w and the LIVE_MAX_W literal beside it were unpinned in test_freeze.py and test_tariff.py, the same gap TEST-06 closed one key over for meter_freeze_s (TEST-10). Measured before the fix: max_w: 2000 -> 4500 in config.yaml left every check in both files GREEN, and LIVE_MAX_W = 5000.0 was a bare literal that silently disagreed with the shipped default (2000) with nothing saying so — for contrast, deadband_w: 15 -> 5 already went RED 2 + 1, so the pinning technique itself was known to work, just not applied here. Fixed three ways. First, test_freeze.py gained a check comparing Tuning()'s code default (control.py, 2000.0) against SHIPPED_MAX_W, read from config.yaml by extending the file's existing _cfg_default() regex reader rather than reimplementing test_arbitrage.py's _shipped. Second, the literal itself is renamed LIVE_INSTALL_MAX_W in both files, with a comment stating plainly that 5000 is the live install's own override and not config.yaml's shipped max_w — the defect was the silent literal, not the number. Third, test_freeze.py now states PINNED_KEYS = ("meter_freeze_s", "deadband_w", "max_w") in one place as the complete set of config keys this suite pins, deliberately excluding maintenance_* (CFG-03 gave those a separate source of truth in app/maintenance.py). Verified by breaking what the new check watches: max_w: 2000 -> 4500 in config.yaml now fails exactly "the code default and the shipped default agree on max_w too" and nothing else, and reverting returns the file to all-green.

Maintenance option defaults lived in three places that had already disagreed, and MAINT-04's tripwire was holding them apart rather than closing them (CFG-03). config.yaml shipped maintenance_charge_w: 2000, main.py carried two opts.get("maintenance_charge_w", 2500) fallbacks, and MaintConfig's dataclass carried a third 2500.0. An options dict with the key absent was therefore accepted by validate.py's rule 6 — which read 2000 — and then built by main.py at 2500, against a 2000 W ceiling. Demonstrated through the shipped code:

options dict with maintenance_charge_w ABSENT, max_w=2000
  validate_startup_config  ->  [] (ACCEPTED, no problems)
  MaintConfig().charge_w   ->  2500.0
  arbiter.resolve()        ->  0.0 W, contradiction=True

That is the bug rule 6 exists to refuse, passing rule 6. Unreachable through the Supervisor, which always supplies every key from config.yaml; fully reachable from sim/inject.py and from the test suite, which is where anyone debugging maintenance is.

maintenance_discharge_w had the identical divergence (config.yaml 2000, MaintConfig 2500) and the card named only the charge side. Closing one key and leaving its twin would have reproduced the defect one line down, so both are closed.

The single source of truth is config.yaml's options: block — the file the Supervisor reads and the operator edits. There is now exactly one in-code copy, maintenance.MAINT_OPTION_DEFAULTS, which is TARIFF-02's PRICE_OPTION_DEFAULTS and SAFETY-24's PEAK_OPTION_DEFAULTS pattern applied to the family that named the card. A mirror rather than a runtime read because the Dockerfile copies app/ and run.sh into the image and not config.yaml: the running add-on cannot open the file it is configured by. test_maintenance.py pins every entry by reading the shipped file, so a drift is a CI failure rather than a comment. Every other declaration site now derives from it or has ceased to exist:

  • MaintConfig's eight dataclass defaults are indexed out of the mirror — no numeric literal survives in the class that held the third opinion;
  • MaintConfig.from_options() is the only place in the add-on that reads a maintenance_* option. main.py's eight inline opts.get(key, <literal>) calls are gone;
  • main.py's second fallback site (the cheap-window charge floor) reads self.maint.cfg.charge_w instead of re-opening the options dict, so the rate the shaping asks for and the rate the state machine drains at cannot be two numbers from one install;
  • validate.py's rule 6 and its maintenance_discharge_w warning take their fallbacks from the mirror.

Where the RANGE lives is now stated and checked, so the next person does not add a fifth site. maintenance_charge_w: int(500,5000) in config.yaml's schema: block is a fourth declaration of a different kind — a bound, not a default. Bounds live in the schema block only: the Supervisor enforces them and reads only that file. test_maintenance.py asserts that every mirrored key has a schema entry (or the Supervisor silently drops the option and the add-on runs on the mirror instead of the operator's value) and that every shipped default lies inside its own range. What the schema grammar cannot express is a relation between keys — maintenance_charge_w against max_w — which is why rule 6 is written in Python and does not belong in the mirror either.

MAINT-04's tripwire in test_validate.py is DELETED, not left passing, as it and validate.py's ⚠️ block both instructed each other to do. Its passing condition was the bug. In its place, the same four consumers exercised the same way and now agreeing: the validator accepts a dict with every maintenance_* key missing, a real Controller built from that dict holds 2000 W, MaintConfig() answers 2000 W with no dict at all, and the real arbiter emits -2000 W, limited by supervised(max_w) instead of 0 W, contradiction=True.

Checked by breaking it, five ways, each observed red before being reverted: move config.yaml alone → the mirror pin fails; move config.yaml and the mirror to 1500 → every consumer follows together (MaintConfig() 1500 W, the Controller 1500 W, the arbiter -1500 W, limited by maintenance(cheap-window charge)) and both suites go green again; retype charge_w: float = 2500.0 into the dataclass → red; restore opts.get("maintenance_charge_w", 2500) in main.py → red; delete a key from config.yaml's options block → red.

Stale prose that asserted the closed divergence as current is corrected in app/watchdog.py, test_watchdog.py and test_peakguard.py.

peak_soc_floor reads like a pack-wide reserve and is not one, and on a sustained-load evening the grid-following loop discharges straight past it to the BMS cut-out (SAFETY-25). The gap has been written down four times without being filed — SAFETY-18's finding (freeze.py), SAFETY-24's module note, its PR body, and its honestly-uncaught 13th mutation — and never once measured. It is measured now, on the committed 2026-08-20 capture, driving the shipped control.compute(), peakguard.decide(), peakguard.claim() and the real arbiter.resolve():

19:00-22:00 UTC, 830 W mean, minimum 701 W, not one watt of export
reference pack (300 Ah x 51.2 V x DoD 90) started at 21 %, one point
above peak_soc_floor

  ends at 10.0 %  -  the bms_soc_floor cut-out
  1525 Wh delivered by the LOOP over 587 cycles
  549 cycles below peak_soc_floor, 343 of them still discharging
  0 cycles on which the peak guard filed any floor at all

And it is a behaviour, not a config value. The same evening ends at 9.9715 % at peak_soc_floor = 5, 11, 20 and 60 — the shipped value and both ends of the schema range — identical to four decimal places. The option an operator would reach for cannot move the number by any amount. On the same day's high-load block the two states coexist: 49 cycles reporting PEAK GUARD FLOOR-LIMITED and, on all 49, the arbiter simultaneously granting the loop up to 2000 W of discharge.

Why SAFETY-24 could not close it. The peak guard files a lo limit — a lower bound. That asymmetry is what makes it provably unable to lower a target, cap a discharge or contradict the arbiter, and it is therefore equally unable to stop a discharge the loop itself wants. A floor on the guard cannot become a floor on the pack by being raised.

What changed is the honesty, on four operator-facing surfaces, because that half is required whichever way the open question is answered and it is the actual misstatement on the live system today:

  • config.yaml says next to the option that it bounds the peak guard only and is not a pack-wide reserve, with the replayed evening and the sweep;
  • DOCS.md says it in the options table and in a new section carrying the figures above;
  • the status-page row for a floor-limited guard carries the scope sentence — it is the one line a human reads at the moment the guard stops, and read alone it implies a reserve the replay shows does not exist;
  • the persistent notification says what has stopped (the guard buying a lower bill) and what has not (the pack being spent).

peakguard.py and freeze.py carry the measurement beside the findings they already recorded.

The product decision is NOT taken here. Whether the loop gets a reserve floor of its own moves real energy on this house and belongs to the owner. DECISIONS/SAFETY-25-loop-soc-floor.md records the options, what each costs and protects, weighed against MAINT-01 and against the fact that this would be the fifth SoC key (OPT-04's arbitrage_soc_floor fired SAFETY-24's "revisit if a third floor appears" trigger unremarked), and a recommendation. It also records a trap found while writing it and now checked through the real arbiter: the obvious shape — a hi limit on the loop — crosses the peak guard's lo and resolves to a CONTRADICTION at 0 W, the battery parked in the quarter that sets the bill, unless bms_soc_floor < loop_soc_floor <= peak_soc_floor is enforced at startup.

test_peakguard.py part 10 is a tripwire, not a guarantee, and part 10f is what makes it one. The replay half records the defect; on its own it could not see the defect being FIXED, because replay_loop() hand-builds main.py's claim list and is therefore blind to any claim main.py adds — which is exactly where a loop-side floor would be built. PR #31's reviewer proved that by building the memo's own Option B in main.py and watching the whole suite stay green. 10f pins the claim-source set: every claims.append(...) in Controller.cycle() is read off its AST and must be one of eight named sources, and real Controller.cycle()s — spied at main.py's own resolve, swept over the whole 0–100 % state-of-charge range in both the idle and the floor-limited state — must hand the arbiter exactly {device, supervised, loop} and {device, supervised, loop, peak}. A ninth source, at any state of charge, in any configuration, takes part 10 red on the line it is written. A floor built inside control.compute() or the guard instead moves 10a–10c's replayed numbers, which the replay drives directly. So the exposure cannot change size under a green suite.

Nine mutations, re-run against the fixed tree, each against a freshly copied tree with no __pycache__ present at all, mounted :ro — the same structural immunity MUTATION.md records for CI. Six are the AC 3 and behaviour mutations already on this ticket's record (the status row's scope sentence, the notification's, config.yaml's, the memo deleted, the loop's gain zeroed, the guard's claim given a hi); two are the reviewer's, and are the ones that motivated 10f — the memo's own Option B at its recommended default, now three checks red where it was fully green, and an absurd always-binding 95 % reserve, six red; one is new, against the banner short form below. All nine are red, no survivors, and no byte delta is +0 B.

The gate has never once graded the content a pull request would land, and a run that never started reported as a test failure (CI-02). Both halves were measured on a deliberately conflicted throwaway pull request rather than read off the workflow, because the Actions log endpoints 404 on this Gitea and a step's own conclusion is the only channel out of a job.

Case 1, and the ticket's mechanism was wrong in a way that made it worse. CI-02 was filed saying a conflicted pull request loses its merge ref, so that git fetch $GITHUB_REF || git fetch $GITHUB_SHA falls through and grades the bare branch head. The symptom was real — PR #14 reported checks / unit -> success while mergeable: false — but the mechanism is not. On this server GITHUB_REF is refs/pull/<n>/head, GITHUB_SHA is the same commit, and git ls-remote origin 'refs/pull/*' advertises no /merge refs at all, for open and closed pull requests alike. The first fetch has always succeeded; the fallback has never fired once. So the gate did not lose merged content on conflicted pull requests — it has never had merged content, on any pull request in this repository's history. Green has meant "this branch passed on its own", which on a base that has moved is not what lands, and block_on_outdated_branch is off on release/1.0 so the base usually has moved.

The checkout now fetches the base tip and the pull request head, merges them, and refuses if the merge does not apply — as its own named step, so /actions/runs/<id>/jobs distinguishes "nothing was tested" from "the tests spoke". Verified by producing it: with the fix on a conflicted pull request the required context went failure in 2 s with the two test steps skipped. The --depth 1 is gone (a merge needs a merge base; a full fetch of this repository is 6.8 MB and 1.1 s), and the fallback survives only on the workflow_dispatch path, which has no pull request to merge and now says so in its output.

Case 2: concurrency: is gone, and cancel-in-progress was never the knob. Runs 531 and 533 on PR #14 were cancelled at 0 s each at the exact second the next run was created, having never started; a cancelled run posts failure on the required context, described Canceled after 0s, and branch protection compares state and not description — so "nothing ran" and "your tests are broken" arrive at the gate as the same red, wanting opposite responses. Three settings were measured with one run holding the single runner slot and two pushes behind it: with no block at all both queued runs survived and executed; with the group kept and cancel-in-progress: false the queued run was still cancelled at 0 s. A shared group cancels a run that has not started regardless of that flag. Having no group is the only configuration measured to leave a queued run alive, and it is what ships. The cost — a developer who pushes four times occupies the shared runner four times — is CI-01's own trade written the other way round: a delayed verdict, never a destroyed one.

test_ci_gate.py grades the gate by running it, not by reading it. It extracts the checkout and merge steps out of checks.yml and executes the shipped commands against two throwaway local repositories it builds — one whose pull request merges, one whose does not — and pins that the old one-liner exits 0 on the unmergeable one while the new steps refuse. It also pins the two tokens that assemble checks / unit (pull_request): renaming name: or the unit: job key would leave every open and future pull request waiting forever on a context that never arrives, with no error anywhere in that sequence. Seven mutations of checks.yml were each confirmed red. .gitea/ci/Dockerfile gains git for it.

What was NOT established, stated so nobody reads more into this. The original report that "no run was ever created for 0942228d" was already corrected on the card — run 533 was created and cancelled — and this work confirms that from the runs list and the per-commit status history. A commit that never had a run carries an empty /statuses/<sha> list; a queued one carries pending / Waiting to run within seconds, and a concurrency-held one pending / Blocked by required conditions. Those are distinguishable at the API. /actions/tasks, which is what was polled originally, lists only tasks that started, and cannot answer the question at all.

The NOT READY banner no longer repeats the row underneath it. status_payload() renders the first hard-failing check as the page headline, so the scope sentence above turned the loudest element on the page into a 550-character paragraph that the checks list then repeated verbatim. A row may now carry an optional short banner form; the floor-limited row does, and its headline is the guard's own line plus a 68-character scope tag. The row itself is unchanged — the checks list is where an operator reads what the floor does and does not bound, and shortening that would have been weakening AC 3. Rows without the key are unaffected, and the page still renders with textContent.

A setpoint device smaller than max_w silently disarmed the frozen-meter detector, and the status page reported it as armed (SAFETY-20). SAFETY-18's conjunction needs abs(commanded_w) >= 0.95 * max_w, but the emitted command is clipped to the setpoint device's own [dev_min, dev_max] range as well as to max_w — in clamp_to_rating() and again as the arbiter's device P_SAFETY limit claim. Measured on the shipped predicate at the ticket's numbers, max_w: 5000 on a ±4700 W inverter:

looks_frozen(unchanged_s=3600, commanded_w=4700, max_w=5000)  ->  False

The command is pinned at the hardware's rail, the meter has been frozen for an hour, and term 2 is unsatisfiable by construction because 4700 < 4750. Any rating at or below 0.95 * max_w disarms the conjunction outright. The page then printed armed (… command is over 4750 W) — a guard that cannot fire, advertising that it can, which is the failure SAFETY-15, SAFETY-19 and validate.py rule 5 all exist to prevent.

The rail is now measured against min(max_w, |dev_min|, |dev_max|) — freeze.rail_ceiling_w(), threaded through looks_frozen(), FreezeWatchdog.evaluate() and both call sites in main.py. An unread rating (hass.limits() returning None when ESPHome is not up) leaves the old behaviour exactly, and correctly: on that path no device clamp is applied either, so max_w really is the ceiling. A rating larger than max_w cannot raise the rail — this is a min(), not a swap. The status row prints the rail the predicate actually uses and names the device when the device is what capped it; the log line and the HA notification do the same, since they outlive the page.

The smaller of the two device bounds, not a per-sign pair. A per-sign rail is tighter and is not wrong, but it is two rails needing two coverage verdicts on a status row that carries one number, and the only configuration that distinguishes them is refused at startup anyway. The symmetric ceiling can only lower the rail, which widens term 2 rather than disarming it; term 1 carries the no-false-positive argument and is untouched.

A ceiling of 0 W is NOT COVERED, not "armed at 0 W". A device that can command nothing in one direction would make abs(command) >= 0 true of every command including a parked one — term 2 degenerately true, collapsing the conjunction into the bare unchanged_s > N threshold TEL-05 refused for false-tripping at this controller's own operating point. rail_unreachable() returns the reason, looks_frozen() stays silent, and the page uses the NOT COVERED row the unsupported-transport case already has — a second reason to use that surface, not a new mechanism.

AC4, decided rather than assumed: no new validate.py rule. The configuration is max_w above the device rating, which rule 2 (CFG-01) already refuses on the identical predicate, re-run by run_control() once the real rating is known. A rail-specific rule would fire on a strict subset of what rule 2 refuses (0.95 * max_w > dev_max implies max_w > dev_max) and could never be the rule that stopped a start. The residue is the state where hass.limits() answered (None, None) and the range checks were skipped — there is nothing to refuse there, by construction, which is why the answer is a runtime row. Written into validate.py's "deliberately not refused" list, and pinned by four checks in test_validate.py so the decision's premise goes red if rule 2 is ever softened back to a warning.

And it was verified by breaking it. Reverting rail_w() to bare max_w fails nine checks; deleting the NOT COVERED handling fails five; and — the one that mattered — shipping the corrected predicate while not passing the rating from check_meter_frozen() originally left the whole suite green, because nothing graded the caller. test_freeze.py part 5b now drives the real cycle() on a ±4700 W device and asserts on the notification that leaves the process; the unwiring mutation fails three checks there. The peak-guard call site's wiring is still ungraded — it sits behind p1_enabled and needs a fed averager to have any observable consequence — and that gap is named in the file rather than implied. A mutation run could grade code that was not there, and the fix is a purge rather than a flag (TEST-15). FCST-03's developer reverted self.provisional to here.provisional, re-ran, and reported a survivor; disassembly showed the source read here while the running code loaded self. CPython validates a .pyc on (source size, source mtime truncated to whole seconds), and a size-preserving edit reverted inside one second moves neither number, so the stale bytecode was reused. That does not make past results wrong - it made them unverified, and the distinction is the whole card.

Reproduced rather than reasoned about. test_bytecode.py builds a real package whose two return values are the same length, imports it in a real subprocess, rewrites it inside the same second and reads back which value ran. Part 1 shows the interpreter running SELF off a file that says HERE.

And it shows the two obvious mitigations do not work. python3 -B and PYTHONDONTWRITEBYTECODE=1 are write-side only: neither stops an EXISTING stale .pyc being read, and a mutation run always has one because the previous run wrote it. The advice already in test_control.py's coverage audit led with -B and is corrected here - the purge is the half that works, and -B earns its place by protecting the NEXT edit rather than this one. No sleep anywhere: one-second mtime resolution is the mechanism, and waiting it out would slow every run down while still only covering the edit somebody remembered to slow.

goodwe_controller/tools/mutation_run.sh is the harness the house adopts: it purges, prints a sha256/byte fingerprint of every app/*.py it is about to grade - so a mutation report can say WHICH source produced it - runs each suite under python3 -B, refuses a tree with no test_*.py (CI-01's rule), and fails if a cache appears during the run. It takes the tree as an argument so the infra repo's replay harnesses can call it.

MUTATION.md states the guarantee where a mutation gets written, and every one of the 16 suites now points at it from its docstring - a list test_bytecode.py derives from the tree, so a new suite joining without the pointer is red.

CI was already immune and is described that way rather than as a hole being closed: checks.yml mounts the checkout -v "$WS:/w:ro", and a read-only tree cannot take a __pycache__ at all - measured, and it fails silently, exit status 0 - while each job rm -rfs its workspace and clones afresh. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces, because the :ro is one character wide. The shipped add-on was never affected: Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was written.

The survey of this week's mutation claims is in MUTATION.md, scoped by the property rather than by re-running everything. The defect is one-directional - stale bytecode turns a red into a green survivor and never the reverse - so every "all red, no survivors" result in the window is not at risk, and the exposure is the recorded SURVIVORS from source-edit runs made before the purge discipline landed on 2026-08-31. Two of them were re-run here under the harness and both still stand (TARIFF-01's record_block() ignoring its policy argument; SAFETY-03's abs() on the clamp limit). The rest are labelled still-unverified rather than quietly assumed or noisily re-run.

Out of scope and recorded: the infra repo's sim/ replay harnesses import the add-on and write bytecode into both trees. Anyone mutating a module graded by a replay must purge both by hand until that repo adopts the harness.

release/1.0 went red at midnight on a commit nobody had touched (TEST-17). Controller.checks() read the capacity-tariff peak with self.peak.peak() - no argument - so tariff.py resolved the month from datetime.now(), while test_tariff.py section 10 banks its quarter at the fixed fixture 2026-08-30. From 1 September the page was correctly asked for September, correctly answered NO_RECORD, and the row read "no completed quarter recorded yet" - a string containing no "peak", which the section's filter required. Four checks failed. The suite had been a latent time bomb since TARIFF-01 merged on 2026-08-30 and every PR that ran it ran in August.

Isolated by holding the commit and the image constant and moving only the clock under libfaketime: green at 2026-08-30, four failures at 2026-09-01, identical at f4914a1, 04292c4~1 and 04292c4. The calendar, not a regression.

The product was right and the test was wrong, so the fix does not change what the live page says. checks() takes when: datetime | None = None and threads it into peak() and warning_frac() - the convention every other peak query in tariff.py already follows. The single production caller passes nothing and still means today. Section 10 now grades at its own fixture's month.

Three new checks make the defect detectable rather than seasonal: the same controller read at two different reference months must produce two different rows, which no clock can satisfy; the later month must read NO_RECORD and stay distinguishable from both an observed peak and an unreadable store; and calling checks() with no argument must still mean today. Verified by mutation - a checks() that drops when is now red at every clock tried, where the old section went green in August. Full suite green, 15 files, at the real clock and at faked clocks in four other months.

One thing left alone deliberately: only the UNREADABLE branch prefixes its row with capacity-tariff peak:. The NO_RECORD row carries neither that phrase nor the word peak, which is what made the original filter brittle and what broke the first draft of the new checks too. It is product text with other suites reading it, so it is noted here rather than changed.

Thirty days of the real meter, and the acceptance criterion three cards deferred is now a number (DATA-01). TARIFF-01 and SAFETY-07 both merged with AC 3 - "monthly peak held under the soft limit in >= 95 % of intervals over a 30-day simulation replay" - honestly unmet, on the belief that only two days of capture existed and nothing longer could be produced. That belief came from a true statement about the past being read as one about the future: HA's recorder still held the whole month. scenarios/p1-net-30d-2026-08/ is 2026-08-01 to 2026-08-30, 485,841 samples, 30/30 days read, 0 failed, 4.13 MB gzipped, in the same schema as the two days that were already there.

tools/export_p1_history.py is the exporter, committed and runnable - the 2026-08-25 one-off was not, and that is exactly why the data was thought unobtainable. It reads day-at-a-time, retries, and never lets a failed read look like an empty hour: a day whose read fails writes no file, is recorded as "read": "FAILED", and the run exits non-zero; the entity is proved to exist before any empty day is believed. Nothing is interpolated, so the month's 13 gaps (1291 s, 99.95 % covered) and its 3 unavailable samples stay visible. --verify re-fetches the two committed days by the same route and reproduces them byte for byte after decompression.

tools/replay_ac3.py runs the month. Over 30 days the criterion measures 98.89 % uncontrolled and 98.99 % guarded, so it is met on that reading - and the uncontrolled figure is the finding: a month with no controller at all passes it. On the other reading of the same sentence it is not met - the guard takes August's peak from 5029.8 W to 4107.3 W, still over the 3500 W soft limit, because once a month peak is set CEILING_MONTH_PEAK defends that peak rather than the cap. Neither number is hidden; both are in that directory's README.

The size decision is committed and measured, not absorbed: a git bundle of the whole history goes from 1.58 MB to 5.28 MB (+3.70 MB, x3.3), which a Home Assistant supervisor clones on every install. Downsampling was not available - meter_max_age_s is 30 s, so any coarser resample converts real coverage into modelled meter-gap and moves the number being measured.

The thirty files sit in a SUBDIRECTORY on purpose: test_tariff.py part 9 and test_peakguard.py part 6 glob scenarios/p1-net-*.jsonl.gz non-recursively, so CI keeps replaying the two small days and does not grow ~50 s per PR. Both files' honesty notes are corrected to point at the month.

OPT-04's AC4 is met: twelve months of real EPEX BE day-ahead prices are now in the repository, and the strategy has been replayed against them (DATA-02). AC4 asked for "net-positive across 12 months of replayed prices". OPT-04 shipped it as NOT MET and replayed a synthetic year instead, because scenarios/ held only P1 meter captures. That was the right call at the time and the wrong diagnosis of why: the criterion was being carried alongside a 30-day meter criterion as though both needed waiting, and EPEX BE day-ahead is public data, not a capture. It needed a fetch, not a month.

scenarios/epex-be-dayahead-2025-09-01_2026-09-01.json — 8760 hourly points, 2025-09-01 to 2026-09-01 Brussels-local, in §9.3's canonical three-field shape. scenarios/fetch_epex_be.py produced it and --verify re-derives every claim it makes about itself without touching the network.

Licensing was checked before anything was committed. The source is Fraunhofer ISE's Energy-Charts API, which publishes the BE zone under CC BY 4.0 from Bundesnetzagentur | SMARD.de and other zones under private-use-only terms — so this zone is redistributable with attribution and the data is committed rather than left as a script plus a checksum. The fetcher refuses to write a file whose per-response license_info stops saying CC BY 4.0. Cross-checked against the upstream: SMARD's own 4996/DE series matched this feed on all 96 quarter-hours of 2026-04-10, maximum difference 0.00 EUR/MWh.

The figures are raw wholesale and the file says so. "all_in": false, with the markup/tax assumption carried in provenance.all_in_assumption as numbers to apply rather than numbers already applied — TARIFF-02's double-counting trap in data form. test_arbitrage.py section 7B applies it in one visible place and asserts arithmetically that its two additive terms cancel out of every daily spread, so the trade counts depend on the VAT multiplier alone and not on the guessed markup. The same replay is run on raw wholesale as well, so how much of the answer rests on the guess is reported (110 trades all-in, 88 raw).

DST is handled by construction, not by a special case. The fetcher iterates in UTC and renders through price.brussels(), so 2025-10-26 comes out 25 points and 2026-03-29 comes out 23 — verified by counting per Brussels day rather than asserting 24, and by checking that October's 02:00 appears twice at +02:00 and +01:00 with two different prices while March's 02:00 does not appear at all. The window is bounded at local midnight: bounding it at 00:00 UTC produced a 22-hour first day, and a 24-hour day silently missing from the end, both of which the point-and-gap accounting caught.

The result, at the shipped default, whatever it is. At cycle_cost_threshold_eur 0.10 widened by FCST-03's no-weather 1.5× to a required 0.1500 EUR/kWh, the real year completes 110 round trips and is net-positive at +24.88 EUR of benefit net of the cycle cost (2 kWh a trade). Unwidened it completes 173. Nothing was tuned: the shipped default and the 2.5/1.5 factors are untouched, and every figure comes out of the same decide().

What the product owner's open decision now has under it. The four independent reports that a static day/night spread of ~0.0840 does not clear 0.10 all stand — a static-tariff site still never trades. What was missing was the other half: a dynamic site's daily spread clears the widened requirement on 121 of 365 days, median daily all-in spread 0.1130. The threshold at which a median day would clear is 0.0754, and at that value the same year completes 156 trips for +35.42 EUR. Both numbers are reported; neither is applied.

And the synthetic year stays, because the real one cannot grade §17. Not one of the 365 real days has a negative dearest hour — 372 negative wholesale hours and 0 days where the strategy would have sold into one — so "0 discharges into a negative-price hour" over real prices is a count of something that could not happen, and deleting the guard would not change it. Section 7B asserts that degeneracy instead of quietly reporting the zero; section 7's generator is still the only thing here that puts a negative price where the strategy would sell.

Size, measured rather than assumed. Plain JSON: 893 KB in the working tree but 74.6 KB as a git object, against 56.5 KB for a committed .json.gz. Git already compresses blobs, so gzipping saves 18 KB and costs a reviewer the ability to read the provenance block — including the licence claim they are meant to check — in the diff. Plain, and load() still accepts .gz for a future dataset that earns it.

Nothing is wired into the add-on. generic_dayahead remains the live fetch path; nothing under app/ imports the script, and the dataset is for replay.

The capacity-peak guard's forced discharge now has an EMS-side energy floor (SAFETY-24). SAFETY-07 can command a discharge to hold a billed quarter down, and nothing below it consulted the state of charge — soc_floor belongs to the maintenance cycle, and freeze.py already recorded that for the grid-following loop "the BMS is the sole energy backstop". On the 2026-08-20 replay the guard asks for 878 Wh in a day. Relying on the BMS is not absurd — it is a real floor and it works — but it is the pack's protection rather than the operator's, and a month of aggressive quarters leaves the battery repeatedly at that cut-out with no EMS-side record of why.

decide() now takes soc and soc_floor, both required and neither defaulted. Above the floor nothing changes. At or below it the guard files a 0 W floor instead of a sized one — one-directional, so charging stays blocked and no discharge is capped — and reports floor_limited with the reason it bound. It is not a trip: every stop in §11.2's table still outranks the claim, and the floor can never be negative, so §9.1's "discharge and export are never capped by the peak guard" survives as a property of the object (swept: 0 negative floors across 1296 combinations of load, elapsed, battery, SoC and floor).

Failing to shave is not silent. A floor-limited cycle raises one notification per episode (goodwe_peak_soc_floor), distinct from the saturation alarm because the two ask the operator for opposite things, and renders its own status row. An unreadable SoC is floor-limited, not a full battery — a full battery is exactly the value that would disarm the floor, and this project has shipped that defaulting once before (| float(100) in the stage-5 loop).

Verified by replay, not by argument. The 2026-08-20 capture is driven against a modelled pack sized from the day's own measured appetite, so it genuinely exhausts: without the floor it reaches the BMS cut-out and sits there for 1227 guard cycles; with it the pack stops at 20.0 % and never touches the BMS. The energy withheld equals the energy between the two floors to within one cycle at the rail. The honest half is reported too — the worst quarter goes from 4338 W to 5030 W, because a floor-limited guard shaves less on purpose.

Two new options, mirrored once. peak_soc_floor (20) and bms_soc_floor (10), whose defaults live in peakguard.PEAK_OPTION_DEFAULTS — TARIFF-02's pattern — imported by validate.py and main.py rather than typed as literals, and pinned to config.yaml by a check that reads the file. CFG-03 still tracks three places. validate.py rule 8 refuses peak_soc_floor <= bms_soc_floor at startup, in CFG-01/MAINT-04's manner. maintenance_soc_floor is deliberately not reused and deliberately not renamed: it is a drain target, not a spend limit, and the rename is recorded as a decision to revisit if a third floor ever appears.

Price arbitrage - the first strategy that trades on a price (OPT-04). Four cards built the price stack and nothing traded on it. app/arbitrage.py is §10.1's priority 3: charge in the cheapest published hour, discharge in the dearest, and only when the spread covers cycle_cost_threshold_eur. It is off by default (arbitrage_enabled: false) - it is the first strategy in this add-on that commands the battery against the meter on purpose.

It consumes the four cards rather than re-deciding anything. Whether a trade is permitted at all, on which two hours, and against which widened threshold is TariffPlan.arbitrage()'s answer (TARIFF-03), and that answer cannot be obtained without first stating whether the peak guard is holding. So §9.1's "give peak shaving priority over arbitrage" is honoured structurally: there is no code path to a tradeable spread that skips the question. And because the claim is filed at P_ARBITRAGE (30) while peakguard files its floor at P_PEAK (50), the arbiter clamps an arbitrage charge even if that interlock were bypassed. Two independent mechanisms, neither re-implemented here.

A guard that never ran is not a guard that is clear. On meter_source: off there is no telegram stream, so the peak guard is never evaluated. That third state is carried as None and it refuses: charging at the rail creates the billed quantity while nothing measures the quarter it lands in. validate.py refuses that configuration at startup too, along with arbitrage armed on a site with no price source at all, and a SoC floor at or above the ceiling.

§17: never export into a negative price. The guard is on the hour being sold into, not on the spread - a day priced -0.30 ... -0.05 has a 0.25 EUR/kWh spread that clears any shipped threshold and a dearest hour that is still negative. Buying in a negative hour stays allowed; being paid to charge is the right trade.

Prices are fetched in the background, never on the tick. resolve_tariff() may open an HTTPS connection, and the control tick is what feeds the ESP32 heartbeat - a supplier's TLS timeout there is a supplier able to push the add-on towards layer 1's 30 s veto. A separate task refreshes every 30 minutes; the tick reads an attribute and an age bound, and a plan whose refresh has stopped answering retires rather than standing as if it were current.

What is honestly not measured. The acceptance criterion asked for net-positivity across 12 months of replayed prices. This repository holds no price history - scenarios/ is P1 meter data - so that criterion is not met, and is not restated. What test_arbitrage.py section 7 does instead is replay a synthetic year and assert the property that does not need real prices: every executed round trip cleared its own widened requirement, on all of them, across a year containing 522 hours priced below zero and zero discharges into one. And at the shipped 0.10 EUR/kWh threshold a realistic Belgian day/night site does not trade at all - reported, not tuned. That number, and the widening factors beside it, are one product decision and it is open.

Provisional prices, and what may not rest on one (FCST-03). Day-ahead prices arrive once a day, around 14–16 h CET. Until they do, §8.3 says the unknown hours use yesterday's profile and are flagged provisional: true — and no irreversible action may be taken on a provisional price. app/price_forecast.py does the fill, and the whole module is shaped by one defect: a carried-forward point and a published one are the same three fields and a bool, so the natural line PricePoint(..., provisional=y.provisional) copies yesterday's False onto today's guess and produces stale data presented as current. That is the meter-side SAFETY-18 failure one layer up — the reading arrives on time, looks fresh, and is wrong.

So the flag is never passed through. Carried points are built by a constructor that has no provisional parameter at all (the literal True lives in one place, and there is nothing for a caller to forget or copy); published points are passed through by identity, so there is no copy that could lose a flag; and an audit re-derives the expected flag for every emitted point from the set of hours the feed actually published and raises rather than repairing one. A published point may itself be provisional — eneco_eddy's current-quarter imbalance print is — so the audit's rule for a published hour is "whatever the feed said", never "False".

The fill keys on the Brussels wall clock, not on t − 24 h. A 23-hour day has no 02:00 and a 25-hour day has two, so a fixed 24-hour subtraction shifts every carried hour by one across a transition and misprices a whole day with nothing to show for it. Re-running the fill after a late publication replaces the carried hours with the real print: the number and the flag move together because the series is rebuilt, never patched.

Arbitrage now drops provisional hours instead of refusing the whole day. The refusal that read "the plan is provisional" would have switched arbitrage off every morning on every dynamic site once carry-forward filling landed — a part-firm series is the normal state before the print. What §8.3 forbids is acting on a provisional price, so the provisional hours are dropped and the spread, the cheapest hour and the dearest hour are computed over the published ones only; fewer than two firm hours is still a refusal, which is where the §11.4 fallback (wholly provisional) lands. The permitting variant now refuses to be constructed around a provisional point at all. The cheap-window flag became per-hour for the same reason, so a site's maintenance charge floor does not go dark every morning.

Real-time / imbalance products get measurably wider thresholds. One widening path, driven by a set of active uncertainty sources: the product's own (§9.2 row 2, derived from the declared PriceProduct and never from a plugin id) and §11.4's "no weather data" row, which the spec widens by a different trigger and which is the same mechanism. The combination rule is max, not a product — two independent doubts must not compound into a threshold nothing can clear. The caller supplies the base round-trip cost threshold, so OPT-04 still owns what the number is; this owns only how much wider it gets and why, and the allowed verdict reports the threshold it cleared.

An irreversible action is a value, not a judgement call at each call site. Irreversible carries the hours an action commits — the maintenance drain's window is derived from maintenance.DRAIN_TIMEOUT_MIN rather than typed twice — and the gate looks at exactly those hours, blocking on a provisional one, on an hour the series does not cover, and on no price data at all: three different reasons, none of them an answer. ⚠️ It is the entry point for a start being justified by a price; the calendar path main.py runs today is untouched, because a gate that blocked on no_data would stop the monthly cycle on every default install — §12's opening sentence.

Zero new options. No config.yaml key, no new defaults dict, no o.get(k, X) in main.py: the module reads no options at all, so CFG-03 did not widen.

The grid-following loop is now capped against the month's billed capacity peak (SAFETY-07). New app/peakguard.py. TARIFF-01 measured the quarter; this is the consumer it was built for. Every cycle the guard projects the open quarter, compares it to a ceiling and files ONE arbiter claim: a lower bound on the setpoint at P_PEAK. That shape is both behaviours §10.1 asks for — a hard clamp on charging and pre-emptive discharge — and it cannot cap discharge or export, because a floor cannot. excess = 900 × (projected − ceiling) ÷ remaining, and the floor is the MEASURED battery power plus that: a floor built on the standing command winds itself to the rail whenever the inverter fails to follow, and one built on delivered power cannot.

It trips where SAFETY-18 only notifies, and the captures decided that. On the healthy reference day it engages on zero of 95 quarters; the action is level-triggered, unlatched and re-derived every cycle, so a false engagement costs one cycle of discharge rather than a parked battery. Replayed on 2026-08-20 the billed quarter goes from 5029.8 W — above the inverter's own 5000 W rating — to 3485 W, under the soft limit and without saturating. Quarters under the limit across both committed days: 189/190 → 190/190. Two days is not thirty; AC 3 is still TARIFF-01's open item and this does not claim it.

Blindness forbids importing, and it is checked before the projection is graded. A fresh averager projects a confident 0 W, which is under every ceiling there is; a meter gap longer than meter_max_age_s makes the projection read LOW; and a frozen meter reading export projects 0 W at full coverage. All three become a floor of 0 W, which is one-directional and cannot cost pack energy. That is the backstop SAFETY-18 could not be — its alarm arrives at 300 s of a 900 s quarter and commands nothing. The frozen term is freeze.looks_frozen() itself, evaluated on this cycle's standing command, not a second copy of the conjunction.

The ceiling is peak_cap_w, raised only by an OBSERVED reading. NO_RECORD and NOT_OBSERVED both leave it at the cap, so an unreadable peak store makes the guard STRICTER. The gate is the reading's STATE, not whether a number happens to be attached to it: today a peak_w is not None test behaves identically, and depending on that coincidence is how a future last-known-peak field would silently raise the ceiling off a read that failed. headroom_w() is deliberately not consumed — cap − peak turns a zero peak into FULL freedom.

Two defects found building it, both in the interaction rather than the arithmetic. A LIMIT does not out-vote another LIMIT — arbiter.resolve() applies every limit at or above the winner's priority and takes the most restrictive — so the peak floor (lo ≥ 0) and the maintenance charge-only shaping (hi ≤ 0) resolved to a CONTRADICTION and 0 W, parking the battery in the exact quarter it should shave. Fixed by suppression rather than priority: main.py drops the maintenance shaping while the guard is engaged, which is what that branch already did for the optional peak_forecast_entity — a key that is empty on a default install, so until now the suspension could not fire on the site that needed it. And thresholding excess > 0 released the claim the instant it started working, producing seventeen engage/release cycles in one 900 s quarter (§10.2's oscillation) and leaving that quarter 49 W over; the threshold is now the floor itself, which is the same arithmetic read as a level rather than as a switch.

PeakTracker.project() no longer reads a private name with a default. getattr(averager, "_last_net", 0.0) failed quiet AND in the disarming direction: a rename credits 0 W held, the projection reads low, and the money guard does not engage. QuarterAverager.held_net_w is now a documented public property, read without a default, and Projection carries it. TEST-13 item 4.

No new option, and no fourth defaults site. The ceiling is peak_cap_w, the coverage threshold is meter_max_age_s, the freeze predicate is meter_freeze_s, and the achievable discharge comes from max_w and the device rating. config.yaml and validate.py are untouched; §14's capacity_peak_limit_kw stays declined as the kW/W mismatch trap it is. On meter_source: off there are no telegrams, so the guard does not run at all and the status page says NOT COVERED — running it there would have blinded it permanently and stopped every legacy install from charging, which is what the first cut did until test_clamp.py's export case caught it.

Static day/night and fully-fixed tariffs, first-class (TARIFF-03). §9.2 puts a large share of the Belgian installed base on a static profile, and an EMS that only works under dynamic pricing is an EMS for a minority. A new static_profile option describes a two-period day/night tariff — or a single fixed price — as JSON, and app/static_tariff.py turns it into the same canonical {start, eur_per_kwh, provisional} series the fetched providers emit, so nothing downstream learns that a tariff can be static.

It is not a sixth provider plugin, and the reason is mechanical. PriceProvider.capabilities() is a classmethod, so a plugin's PriceProduct is fixed when the class is written — but §9.2 makes STATIC and FIXED two different products with two different required behaviours, and which one a site is on is a property of the operator's data, not of any class. StaticProfile.product derives it from the number of distinct prices instead. The second reason: the plugin framework exists to stop a fetched figure being marked up twice, and a number the operator typed as all-in has no publisher to disagree with.

So the profile sits where §11.4 already says it does — under the providers, as the fallback. The configured-product path and the feed-is-down path are the same generator differing in one flag: provisional. A static-tariff site runs that path every day, so the degradation path for a dynamic site cannot rot unused.

"No arbitrage" is a type, not a boolean somebody has to remember to check. TariffPlan.arbitrage() returns a variant: the allowed arm carries the spread and the cheapest and dearest hours, and the refused arm carries a reason and nothing else — .spread_eur_kwh on a refusal raises rather than answering 0.0. An optimiser cannot compute a trade from a refusal because it cannot get the inputs out of one. Four refusals, all derived: the peak guard is holding, there is no price data, the plan is provisional, or the series is flat. That last one is AC2 — a fully-fixed tariff disables arbitrage by arithmetic rather than by matching on an enum, and a dynamic feed that happens to print one price all day is refused for the same true reason.

Peak shaving outranks arbitrage, expressed so OPT-04 cannot skip it. arbitrage() takes peak_guard_active as a required keyword argument, so the spread is not obtainable without first answering whether §10.1's priority 2 is holding. §9.1's capacity tariff is a network cost charged whatever the energy product is.

Time-window shifting reaches the one shiftable load that exists. main.py's cheap-window flag — previously fed only by the price_now_entity / price_avg_entity pair — now falls back to the static profile, and the Web UI gained a Tariff row naming the window, the price, when it next changes and why it is or is not cheap. The rule is strictly below the seven-day mean: under a flat tariff <= would call every hour cheap and a fixed-tariff site would top up from the grid at any hour, which is the opposite of self-consumption only. Seven days rather than 48 hours because a 48 h mean taken on a Friday is two-thirds weekend, and the same Tuesday 09:00 would come out cheap or dear depending on when you asked.

A profile must tile every day type exactly once, checked at startup. A gap is refused with the uncovered range named rather than filled in — an invented price is one an optimiser would trade on — and an overlap is refused because otherwise one of two prices wins silently on list order. The trap this catches in practice: 22:00–07:00 mon-fri does not cover Saturday morning, because a window applies on the day the clock reads.

validate.py rule 7's stated reason expired, exactly as TARIFF-02 predicted. That ticket left a tripwire in test_price.py section 12 asserting that nothing in app/ consumed load_prices(), with instructions to fix the refusal's wording in the same commit when it went red. It went red naming static_tariff.py. The message now says what is true instead — the series is consumed, but main.py acts on the static side of it and not on a fetched one — and the tripwire is re-aimed rather than removed: the consumer set is pinned, so a second consumer (OPT-04) goes red again, and the expired phrase is asserted gone so a bad merge cannot restore it. Rule 7 also grew a second refusal: static_profile alongside the Home Assistant price pair is the same silent-loser conflict, and a live one.

No new place for an option default (CFG-03 is not widened). static_profile was added to app/price.py's PRICE_OPTION_DEFAULTS — the one in-code mirror TARIFF-02 created and pinned to config.yaml by a check — rather than to a defaults dict in the new module, which has none. main.py grew no o.get("static_profile", …) fallback. That is TARIFF-02's pattern, stated here so a reviewer does not have to infer it.

Measured, on the data that exists. test_static_tariff.py replays the two committed days of this house's real P1 meter (scenarios/p1-net-2026-08-{20,23}) priced under a Belgian day/night profile. 2026-08-20 is a Thursday: 15.220 kWh imported, 9.606 in the day window and 5.614 in the night one, EUR 4.7185 under day/night against EUR 4.6725 flat, and shifting the day-window energy into the night window saves EUR 0.8069 — which is 9.606 kWh x the 0.0840 spread, derived twice and required to agree. 2026-08-23 is a Sunday: 0.728 kWh, all of it night-priced, which is the weekend row proving itself on real data. §17 names six Belgian scenarios and a static-profile case is not among them; this is the seventh, and it is two captured days rather than a season — the file says so rather than implying an annual figure.

Also worth knowing before OPT-04: on realistic Belgian day/night numbers the whole-tariff spread is about 0.08 EUR/kWh, below the shipped cycle_cost_threshold_eur of 0.10. A correct optimiser will decline to cycle for the tariff alone on such a site. That is a product finding, not a defect.

Price provider plugins, and one canonical all-in price format (TARIFF-02). app/price.py ships five providers - generic_dayahead (wholesale EPEX BE), engie_dynamic, totalenergies_dynamic, eneco_eddy and the offline manual_csv - all emitting exactly {"prices": [{"start", "eur_per_kwh", "provisional"}]}, tz-aware at the Brussels offset, EUR/kWh, all-in. Nothing consumes it yet: this is the seam, landed first, so that the arbitrage work that follows never learns a supplier's name.

Double-counting the markup is refused rather than discouraged, given a correct declaration. A plugin does not return a price; it returns the figure its source published and declares which of {energy, markup, taxes} that figure contains. The framework adds the complement, once. Engie and TotalEnergies publish a retail figure with their margin already inside; adding the configured 3 c/kWh on top would make every future arbitrage decision wrong by that amount with nothing reporting it.

Two mechanisms, because one was not enough. PluginOptions raises on the framework-owned keys - and review of PR #16 then wrote a double-counting plugin three more ways, one of them touching nothing but PRICE_OPTION_DEFAULTS, a public dict in the module every plugin already imports. So register() now also refuses at import any plugin whose own code mentions a framework key (code_leaks(), docstrings stripped via ast so a plugin's mandated SOURCES: line does not false-positive). Honest wholesale baseline 0.188 EUR/kWh; every attack landed 0.219.

The guarantee's precise shape, stated because an overclaim is worse than no claim: the framework adds the complement exactly once given a correct sources declaration. A plugin that declares {energy} while its feed is really all-in still comes out one markup high while touching no framework name, and no code can catch that - the declaration is the plugin's unverifiable claim about somebody else's tariff. What is mechanised is reachability; what stays human is truthfulness.

The product type is declared, not inferred from the plugin's name. eneco_eddy is a real-time/imbalance product and gets widened arbitrage thresholds; that reaches a consumer through capabilities().product and volatility_regime(), never through a name comparison. test_price.py asserts mechanically that no plugin id appears anywhere in the framework's own code, and drives a sixth provider defined inside the test file to the correct regime with price.py untouched.

"No price data" is a type, not an empty list. Following the same rework sim/riglock.py took, a fetch returns PriceRead.series(...) or PriceRead.no_data(reason), and only the first carries fields. An empty series is not constructible; no_data has no .points to iterate, no .at(), and .get("points", []) raises rather than returning the default. A day of free electricity and a day with no prices are different instructions - arbitrage is pointless under the first and forbidden under the second - and an implementation that returns [] on a failed fetch cannot tell them apart. Every site-level failure returns no_data; nothing raises into the control tick.

What is not verified, and cannot be by an offline suite: every fixture is synthetic, so the five feed URLs and JSON shapes are checked against a belief about what those suppliers publish, not against the feeds. The parse layer is exercised; the contract with each supplier is not. Expect the first live fetch of each to need a shape fix, and note that a wrong shape degrades to no-price-data rather than to a wrong price.

manual_csv is the documented offline fallback and needs no network, no supplier account and no HTTP stack. See DOCS.md for the format. Its start column must carry a UTC offset - a bare local timestamp is refused, because one hour every October names two moments.

Injection is priced separately (export_price_eur_kwh), a scalar rather than a second series, and negative values are accepted. Consumption plugins cannot reach it.

price_provider may not be combined with price_now_entity / price_avg_entity - the add-on refuses to start on that pair. The Home Assistant sensors are the existing delegation of pricing to HA and still work alone; with both configured they would silently keep deciding while the status page named a supplier that decided nothing.

No timezone database is used. The shipped Alpine image has no tzdata, so Brussels offsets are computed from the EU rule and every instant is carried as UTC and rendered at the offset that applies to it. The checks drive both 2026 transitions - the 23-hour and 25-hour days - rather than a normal day, where a fixed 24-slot implementation and a correct one agree.

The capacity-tariff peak is now measured, banked and survives a restart (TARIFF-01). New app/tariff.py. The 15-minute block average itself was already built and unwired - p1.QuarterAverager computes clock-aligned 900 s blocks, time-weighted over irregular telegram spacing, offtake-only and per-phase - and P1Ingest.blocks was a 96-entry list a restart erased. This adds the SQLite behind it (/data/tariff.db): one row per completed quarter in the indefinite 15-min tier, one row per calendar month in the permanent peak tier, and no DELETE against either anywhere in the module.

Blocks, not a sliding window. The card says "rolling"; 9.1 bills "the highest 15-minute average offtake", stated per QUARTER. "Rolling" here means continuously updated, not a trailing-15-minutes window - a trailing window reports a peak the meter never bills, and reports it HIGH, because a burst straddling :15 fills it completely while contributing to two block averages at partial weight.

A restart mid-block resumes it, and a restart that outlives the block banks it. QuarterAverager grew snapshot()/restore(); the tracker checkpoints the open block every 15 s (worst case 1.7 % of one quarter) and clears the checkpoint in the same breath as a block close. The held sample keeps its ORIGINAL timestamp across the restart, so the outage is integrated under the same max_hold_s rule a running process would apply and uncovered seconds drag the closed block DOWN rather than being held forward. quarter_start is the primary key and a re-bank may only ever RAISE a figure, so a replay cannot double-count and a partial re-run cannot lower a quarter already measured.

An unreadable store is not a zero peak. peak() answers OBSERVED / NO_RECORD / NOT_OBSERVED and carries peak_w = None unless observed - the riglock.holder() fix applied to something that spends money. A peak read as 0 W hands SAFETY-07 maximum headroom and silently disarms the guard at the moment its own storage breaks, so there is no accessor that defaults it: a caller who forgets gets a TypeError, and the status page prints a different row for "no quarter yet" than for "the database did not answer".

Calendar months are LOCAL, blocks are UTC. A quarter starting 22:15 UTC on 31 August bills in September. Block alignment still needs no timezone.

No new option, and no second peak entity. The soft limit is the existing peak_cap_w; config.yaml and validate.py are untouched, so CFG-03 is not widened. peak_forecast_entity stays the input to maintenance_charge_floor()

  • repointing that consumer changes what moves energy and belongs to SAFETY-07.

It measures and nothing else. No claim, no clamp, no command; graded on the parsed syntax in test_tariff.py, which also proves the same grader lights up on main.py. Per SAFETY-20, the quantity is DELIVERED power - tariff.py only ever sees P1Sample, the meter's own reading, never a setpoint.

AC 3 is not met and the check says so. It asks for 30 days of replay; two days of this house's real meter exist (2026-08-20, 2026-08-23), now committed as scenarios/p1-net-*.jsonl.gz. test_tariff.py part 9 replays them, reports the percentage under the shipped limit next to the sample size in days, and asserts nothing about the 95 % figure.

A computed setpoint over the rating now alarms instead of being clipped in silence (SAFETY-03). The clamp was never the missing half - specs.md 10.3 records an unclamped integrator climbing ~130 W per 4 s past 10 kW and reporting 14 768 W while pinned at the 5 kW rail, and a silent clamp turns exactly that into a flat, legal-looking 5000 W hold. write_setpoint() - the one path every write takes, cycle, heartbeat, operator button and shutdown alike - now clamps to the validated max_w and reports whether the raw value differed, and Controller.check_output_clamp() raises OUTPUT_CLAMP: a persistent notification (goodwe_output_clamp), an ERROR, an event row and a red status banner. Not a trip: the clamped value is written and the loop keeps running, per 11.2's "clamp and alarm".

The bound is max_w and nothing is min()ed at runtime. Section 14 requires the loop clamp and the driver's setpoint_limit_w to agree, validated at startup with a refusal on mismatch - which CFG-01 already ships. The device range is still applied second, as defence in depth; after a successful validation it cannot engage, so if it ever does, that is louder than the first stage and it alarms too, naming the bound. No new config key: the guard's limit is the one the operator already set, and its cadence is a module constant.

Decision grew i_clamped / clamped booleans, and that is the load-bearing part. reason is one string that later stages overwrite - a cycle that clamps the integrator and is then slew limited reports slew-limited, and one that clamps while saturated reports saturated-freeze. Both are the winding case, so an alarm keyed on the string is silent on exactly the cycles it exists for: mutating main.py back onto "clamp" in decision.reason drops the 10.3 replay from 2 engagements to 0. The flags are set where the clamp happens and are never overwritten. On a default install (integrator_max_w following max_w) the integrator bound is the one that bites and the output clamp is unreachable, so the integrator flag is the whole signal.

Distinct from the saturation freeze, and checked in the negative. A clamp is a software bug signal; saturation is the hardware failing to follow a legal command, and its action is to freeze the integrator, not to alarm. They share no reason code, notification id, status row or counter. test_clamp.py drives a loop that saturates for 10 consecutive cycles at 1.4 % of the rating and asserts zero clamp notifications, zero engagements, no log row and no status row - after first asserting that the saturation freeze really did engage, so the silence is an observation rather than a scenario that did nothing.

The action log is coalesced per episode, and that was a real bug. log_event() keeps 40 rows; one row per engagement flushed the entire ring within 40 cycles of a winding loop, and the first thing it evicted was SAFETY-18's own METER FROZEN? row - this guard silencing another guard's log. Caught by test_freeze.py going red, not by inspection. One row per episode now, carrying the exact engagement count read off the counter.

A non-finite setpoint is refused, and it was worse than passing one through. nan is loss of input (11.1 rule 1: command zero, keep commanding), not an out-of-range value. Measured: because every comparison against nan is False, a naive max(-limit, min(limit, nan)) keeps its first argument and turns a nan into a command at the full rating, then reports it as a clamp engagement.

Review fixes (PR #12). Three, and the first was a behavioural regression this PR introduced: clamp_to_rating() returned early from the max_w stage, so the device bound - the "applied second, defence in depth" half - was reached only when the rating bound had NOT fired. The bigger the overshoot, the less the guard did. At max_w 5000 against a +-4000 device, +9999 emitted +5000 W, outside the device range, while a mere +4500 was correctly held to +4000. That undid the pre-PR guarantee "never send a value the device will reject outright" and undercut this module's own case for clamping to max_w rather than a runtime min(), which rests entirely on that stage catching a validation that did not run. Both stages now always run, the result names both bounds when both bite (max_w+device), and the property is asserted over a 492-point sweep rather than on witness values - the defect was invisible to any single-value check that happened to sit inside one stage. No reachable production path was found for it (two validation gates and the arbiter bound sit in front), but latent is not harmless.

Two harness defects, both of the kind where a check cannot fail for the value it forbids: the hysteresis check issued range(CLEAR_CYCLES - 1) clean cycles, which at CLEAR_CYCLES = 1 issues zero and passes while printing "0 clean cycles do NOT clear it" - green for the chatter setting the constant exists to prevent. And the re-assert check stimulated at REASSERT_S + 9, green for any value including 3600, i.e. the hour of silence the module promises not to produce. Both are now written in wall-clock terms that do not move when the constant does: one clean cycle must not clear the alarm, and a loop pinned across the 900 s capacity-tariff quarter must speak at least 5 times and on no more than 20 % of cycles. CLEAR_CYCLES = 1, REASSERT_S = 3600 and REASSERT_S = 0 each go red.

test_clamp.py (new, assert-based, no framework) covers the clamp arithmetic and its boundaries - exactly +-max_w is not an engagement - the alarm's edge/re-assert/hysteresis cadence, the 10.3 runaway replayed through the real Controller.cycle() against an unclamped transcription, the saturation negative, and the direct-write path. Six author mutations reproduced red, including "clamp kept, alarm deleted" (the historical build) and "alarm keyed on reason". Two of the check's own hypotheses about how the freeze and the clamp interact were refused by the sweep and rewritten to what it measured: a frozen cycle can clamp, and does so exactly when the integrator reverses.

test_freeze.py's notification assertions now filter by notification_id rather than by service - the add-on raises more than one kind of notification, and its railing scenarios legitimately raise this one too.

Cheap-window maintenance charging was unreachable at the shipped defaults, and now the config that makes it unreachable is refused (MAINT-04). config.yaml shipped max_w: 2000 against maintenance_charge_w: 2500. The cheap-window shaping files Claim.limit(hi = -maintenance_charge_w) against the supervised SAFETY limit's lo = -max_w, so lo > hi — the arbiter's clause 3, correctly resolved to 0 W and logged as a CONTRADICTION. Maintenance silently never charged in a cheap window on a default install, and the only evidence read like a bug in the arbiter rather than like the two numbers an operator set. Measured against the real arbiter, loop asking +500 W:

max_w=2000  hi=-2500  ->     +0 W  contradiction=True
max_w=2500  hi=-2500  ->  -2500 W  limited by supervised(max_w)
max_w=3000  hi=-2500  ->  -2500 W  limited by maintenance(cheap-window charge)

validate_startup_config() now refuses maintenance_charge_w > max_w (rule 6), the same shape as CFG-01's sign_disagree_w >= max_w: a number the operator set, overridden by a layer they cannot see. Equality is reachable (-max_w is a single valid point) and deliberately not refused. Verified by starting the add-on on the pre-fix pair: exit 78, the refusal banner, no traceback.

maintenance_discharge_w was checked, not assumed, and it is NOT the same case. The shaping is not symmetric. The drain phase does not shape the loop, it OWNS the actuator — Claim.set(P_MAINTENANCE, +discharge_w) — and a SET is clamped by the limits above it rather than contradicted by them. 2500 against a 2000 W ceiling emits +2000 W, and the arbiter's own explain() prints maintenance -> 2000 W, limited by supervised(max_w) every cycle. Nothing is silent and energy still moves; the cycle completes slower (13.8 kWh usable at 2000 W is ~6.9 h against the 720 min drain timeout). Warned about, not refused.

The shipped defaults changed so the validator does not reject them. maintenance_charge_w and maintenance_discharge_w are now 2000, at the shipped max_w. max_w was deliberately NOT raised instead: it is the supervised safety ceiling and raising a default upward ships more power to every new install. Raising max_w (the reference install runs 5000) is what unlocks a faster maintenance cycle — raise it first, then these. test_validate.py now reads config.yaml itself and asserts the shipped numbers pass the rule, so a default that the validator refuses cannot ship again.

⚠️ Upgrading an existing default install: the add-on may refuse to start

An install still carrying maintenance_charge_w: 2500 against max_w: 2000 now meets rule 6 and exits 78 with the refusal banner instead of starting. That is the intended behaviour — the configuration was already broken, it was just silent about it — but an add-on that will not come back after an update needs the fix stated here rather than only in the log.

The fix, either way: set maintenance_charge_w to 2000 or lower, OR raise max_w to 2500 or higher (Settings → Add-ons → GoodWe RS485 Controller → Configuration), then start it. The banner in the log says the same thing and names both numbers.

Whether you hit this at all depends on whether the Supervisor kept the old value, and both cases are covered above because we did not verify which one applies here. The Supervisor merges an add-on's stored options over the defaults in config.yaml, so:

  • A key the operator never edited re-derives from the new config.yaml and becomes 2000 on upgrade. Non-event, nothing to do.
  • A key the operator did set persists at 2500 and the add-on refuses to start until it is changed. Note this includes anyone who used the Configuration page's YAML editor, which writes the whole options block back — so "I never touched that field" is not a guarantee the old value is gone.

⚠️ This is reasoned from the Supervisor's documented merge behaviour, not measured on the live install. The reference install's stored options could not be read (/api/hassio/ refuses a long-lived token) and probing it was out of scope — it regulates a real battery. It runs max_w: 5000 and is unaffected either way.

⚠️ Known, deliberately left, and worth a follow-up: main.py and maintenance.py still fall back to 2500 when the key is absent from the options dict, while config.yaml and validate.py now say 2000. Unreachable on a Supervisor install (every key is always supplied) and reachable only from tests/sim. The real fix is one source of truth for option defaults, which is bigger than this ticket and touches files another ticket is in.

0.5.2

A meter frozen at a wrong-but-fresh value now raises an alarm. It still is not stopped. (SAFETY-18)

A meter that answers 200 OK with a stale document forever is arriving on every poll, so every freshness mechanism in the stack reads it as healthy: meter_max_age_s is reset by each response, the firmware watchdog is fed by the heartbeat and by a sample age that never climbs, and the arbiter contributes only ±max_w. The loop integrates a constant error and rails — replaying the real compute() at 15 s cycles, in 150/60/30 s at max_w: 2000 for a meter frozen at 350/1000/≥3000 W, and 360/135/75 s at max_w: 5000. The live install runs max_w: 5000, which is both the schema maximum and the device rating.

The new detector (app/freeze.py) is a conjunction, not the bare unchanged_s threshold TEL-05 measured and rejected:

unchanged_s ≥ meter_freeze_s   AND   |command| within 5 % of max_w

Both terms already existed and were already on the status page. They fail for independent reasons: at the converged point the command is nowhere near the rail, and at the rail against a real load the kWh registers move within seconds. At the shipped 300 s there is also a structural relation, not just a margin — the slowest a healthy 1 Wh register can tick and still look unchanged is 12 W, which is inside the 15 W deadband, so the command there is parked at 0 W and the two halves cannot both be true.

Notification only, deliberately. An HA persistent notification (fixed notification_id, so a repeat replaces rather than stacks), an ERROR log line, a UI event and a red status banner. No claim, no latch, no 0 W: a false trip parks the battery and the operator's next move is to switch the guard off; a false notification costs an alert. The trip is a separate decision that needs data from a real install.

  • New option meter_freeze_s (default 300, range 60–3600, no "off").
  • Only meter_source: homewizard_local is covered — it is the only transport that sees the meter's own document. Everywhere else the status page says NOT COVERED rather than "armed".
  • DOCS.md now states the capacity-tariff exposure this does not close: peak_cap_w caps maintenance charging and nothing caps the loop, so a lying meter can drive a 5 kW unattended import, and ≥15 minutes of that sets the month's billed peak (measured: one 4998 W quarter moved a monthly peak from 4832 → 5013 W). That cap is SAFETY-07.
  • test_freeze.py grades it in both directions: silent over 40 minutes of the live house's real converged capture (committed as scenarios/p1-age-2026-08-26.jsonl.gz), silent over an hour of TEL-05's low-power case where a bare threshold is shown to fire, and alarming on a genuinely frozen meter driven over real HTTP through the real HomeWizardLocalSource — against the rig's own hwsim freeze fault when the infra repo is reachable, an equivalent stub otherwise. Its negative twin is the load-bearing one: the same railed command against a meter that is still moving must stay silent at the same threshold.

0.5.1

SAFETY-02's latch now survives an add-on restart, which is the difference between a latch and a pause. auto was persisted and sign_wd.tripped was not, so reconstructing the Controller against the same store — exactly what a container restart does — brought it back armed, into the same fault, with no operator involved: tripped=False, banner back to NOT READY, and it resumed commanding (measured: −1000 W, −2000 W) before re-tripping 180 s later. Under a Supervisor that restarts a crashed add-on that is a loop of three-minute wrong-direction bursts — and "restart the add-on" is the first thing an operator looking at a FAILSAFE banner and a 0 W inverter will try.

sign_tripped and sign_reason are now Store keys beside the maintenance state, written the moment the trip happens (reason first, flag second, so a crash between the two can never persist a latch with no explanation) and restored in Controller.__init__. Cleared only by the operator's start. DOCS.md said "it does not clear itself"; that was false across a restart and now is not.

Also in this release, all of it review follow-up rather than new behaviour:

  • The arming gate is tested against the real arbiter. It was the decision the whole ticket turns on and it was asserted in three comment blocks and verified by nothing — every case passed following in as a literal. test_watchdog.py now derives it from resolve() across twelve claim configurations, including the redirect case winner == "loop" alone would have got wrong and the lo limit that raises magnitude without flipping sign.

  • The MQTT status: "failsafe" value is tested. The check that claimed to cover it restated the assertion three lines above it and never touched the payload.

  • A forward hazard written down where it will be read, and made to bite. winner == "loop" disarms the watchdog under any higher-priority SET claim. Today only maintenance and the safety stops emit one and neither follows the meter; a peak-shaving strategy at P_PEAK does, and would blind the watchdog for every peak event.

    The gate is now watchdog.loop_is_following(), called by both main.py and the test, for the same reason disagrees() was extracted: the test held a transcription of the shipped expression, so editing the shipped gate alone to winner in ("loop", "peak") left every suite green while the watchdog went blind. Two copies, and the one that drifts is the one doing the grading.

    ⚠️ Extracting it was not sufficient on its own. The realistic P_PEAK row — peak shaving asking for more than the loop — still could not detect the widened gate, because the magnitude term rejects it regardless and masks the winner term. A second row with peak asking for less isolates winner as the only deciding term, and that is the one that turns red.

  • The worked example described a configuration that does not ship. At the defaults maintenance_charge_w (2500) exceeds max_w (2000), so that claim is an arbiter contradiction resolving to 0 W, not a −2500 W charge. The example is now written at 1500 W. (The contradiction is a real pre-existing bug — a default cheap-window maintenance charge silently never happens — filed separately, deliberately not fixed here.)

  • disagrees() is public, so sim/replay_sign.py stops carrying its own copy of the predicate it grades.

  • held_s takes the clock instead of reading one, restoring the pure-function property the module advertises.

  • The sign_reason-before-sign_tripped write ordering is enforced, not just documented. Swapping the two lines used to pass every check. A store that fails the second write now proves the property the ordering exists for: what survives a crash mid-trip is a reason with no latch, never a latch with no explanation.

  • Measured figures corrected throughout: 93.4 % / 4212 of 17280 (was 92.9 % / 4127 of 16349), per-cluster 0.3 / 0.9 / 10.5 / 0.0 %.

0.5.0

SAFETY-02 — the sign-disagreement watchdog. The add-on now watches whether the setpoint it is emitting and the grid figure it is regulating on point the same way. If they oppose each other, both over sign_disagree_w (300 W), for sign_disagree_s (180 s) continuously, it files a failsafe claim at P_SAFETY, commands 0 W, and latches there until an operator starts control again. New module app/watchdog.py; new options sign_disagree_w and sign_disagree_s.

This is the gap the existing failsafes leave open. The stale-input watchdog asks whether the meter is still talking, the saturation freeze asks whether the inverter can follow, the output clamp asks whether the number is too big — a loop can pass all three while charging the battery out of the grid, because the only thing wrong is the sign. On 2026-08-20 a commercial controller did exactly that four times in one day, for up to 77 minutes at a stretch, and reached a commanded −14 768 W against a ±5000 W inverter.

Validated against that day. sim/replay_sign.py in the infra repo drives this module over the committed RS485 captures of both 2026-08-20 (the four episodes) and 2026-08-23 (healthy): 18 trips on the fault day, every one inside a window NOTES.md §4.7 accounts for, and 0 on the healthy day. The four episodes do share one signature rather than merely resembling each other — sign agreement runs 0.3 / 0.9 / 10.5 / 0.0 % inside them against 93.4 % on the healthy day.

Three decisions worth knowing about:

  • It is disarmed whenever the grid-following loop is not what is driving. Sign agreement is a property of a loop that follows the meter. A maintenance grid charge opposes the meter by design — 2500 W of charge into a house drawing 500 W is +3000 W on the meter against a −2500 W command, for hours — and armed unconditionally this would trip on every maintenance cycle. The gate tests the emitted number, not the winning claim's name: a limit claim can let the loop "win" and still replace its value with one pointing the other way.
  • The trip latches. Commanding 0 W removes the command side of the comparison, so the disagreement always clears the moment the trip works. Un-latched, this would trip, clear, and hand the actuator back to the loop that was driving the wrong way, every three minutes forever.
  • sign_disagree_w at or above max_w is refused at startup (validator rule 5). The arbiter never lets a command exceed max_w, so such a threshold makes the watchdog incapable of firing while the status page still reports it armed. A disarmed guard that advertises itself as armed is the failure mode this project keeps refusing to ship.

What it does not catch, stated so nobody assumes otherwise: an inverter that acts opposite to what it was told moves the meter further the same way, so command and meter agree while everything runs away. That is the saturation freeze's job, which compares the command against the battery's actual power.

test_validate.py's "the smallest sane max_w still starts" case now names a reachable sign threshold, because a 1 W ceiling genuinely does disarm the 300 W default and is now correctly refused.

0.4.0

CFG-01. The add-on now refuses to start on a configuration it cannot honour, instead of logging a line and carrying on. validate_startup_config() runs in amain() before the broker, the web server or any task exists, so a refusal cannot leave half a controller running behind a UI.

It refuses only where continuing produces one of two outcomes: (a) a stated limit is untrue - the operator configured a bound and a lower layer silently enforces a different one - or (b) the add-on is inert and indistinguishable from healthy. (b) is not a special case of (a): with no setpoint_entity, layer 1 pinning the inverter at 0 W is the failsafe working. The system does not become unsafe, it becomes a convincing impression of a working controller.

Four things qualify:

  • max_w above (or below) the setpoint device's own rating. This is the one that changed behaviour. It used to warn the device wins and run anyway, with write_setpoint() silently clamping, so the configured ceiling was never the real one and the only evidence had scrolled off the log. The refusal names the configured value, the device's value, and which wins.
  • No setpoint_entity. A controller with no actuator: every write is a no-op, the device rating is never read, and the ESP32 heartbeat that holds off the layer-1 failsafe never happens. It ran, looked healthy, and moved nothing.
  • A meter_source that can never produce a reading - missing p1_host, missing p1_net_entity, a blank MQTT topic, a phase list disagreeing with meter_phases, an unknown source name, or a meter_poll_s at or past meter_max_age_s. These were already caught, but they only disabled ingestion, which leaves the grid reading None forever: permanent "inputs missing", 0 W, and a status page indistinguishable from a healthy meter nobody has sent anything to yet.
  • meter_max_age_s above the firmware's ingest veto. The schema accepts int(5,300); the ESP32's threshold is a compile-time max_age_s: "30" and it trips layer 1 at p1_age_s >= 30. Set 120 and the add-on treats a 119 s reading as fresh and keeps commanding, while the firmware has already vetoed and is holding the inverter at 0 W - healthy meter, running controller, nothing moving, and no line anywhere saying the number you set was overruled. Structurally the same fault as the max_w case. Only above the veto is refused: below it the add-on gives up first, which is fail-safe and visible on its own status page. Mirrored as validate.FIRMWARE_INGEST_VETO_S - it cannot be imported from a compile-time YAML substitution, so it carries a note about the one direction in which it can go stale.

max_w at or below zero is refused too. Schema-blocked on a real install, but validate_startup_config() is now also the simulation suite's entry point, and a non-positive max_w inverts the arbiter's supervised bounds into a contradiction that resolves to 0 W - i.e. it would read as a safety trip rather than as the typo it is.

The predicates for the meter group still live in p1.validate_meter_options(), which build_source() also calls - one definition, two callers, not two competing validators. Two transports gained a check they never had: ha_dsmr with only one of its two entities, and mqtt_p1 with a blank topic, both of which previously built a transport that could never read.

Deliberately not refused, because it is untidy rather than unsafe: integrator_max_w above max_w (the arbiter still bounds the wire to ±max_w, so the cost is unwind latency, not amperage - warned), a missing soc_entity / batt_entity (fail-safe, and already a red NOT READY banner naming it), a setpoint_entity that has not appeared on the Core API yet (ESPHome is routinely late; refusing would make a slow boot need a human - re-checked once the real rating arrives), and a thin-but-nonzero meter_poll_s margin.

A refusal is legible as a refusal: a banner that says in words that this is a configuration problem and nothing is broken, the numbered problems, no traceback, and exit status 78 (EX_CONFIG).

SAFETY-12. The control loop now evaluates on a clock as well as on a change. run_control() ran cycle() only when the meter value differed from the previous poll, so a meter that repeated a value ran no control cycles at all - while the heartbeat went on re-emitting the last command and the firmware went on putting it on the wire every 2 s. Layer 1 stayed fed, every indicator read healthy, and a command computed from an old reading kept being executed through whatever the load did next. Measured on the rig during TEL-05: 70 s at a literally constant 350.0 W with 14 arrivals and zero cycles.

It was worse than a latency limit: it was a safety claim that could not fire. stale_input_s and the inputs missing -> 0 W claim both live inside cycle(). Pre-fix, if the meter value happened to be constant, cycle() was never called again - so that claim had no way to run. Constant meter, SoC entity dying at t=4 s, same binary:

pre-fix    writes: [(0.0, 220.0), (0.0, 220.0), (10.1, 220.0)]
           final target: 220.0 W   reason: 'loop -> 220 W'
post-fix   writes: [(0.0, 220.0), (0.0, 220.0), (3.0, 430.0), (9.1, 0.0), (10.1, 0.0)]
           final target: 0.0 W     reason: 'safety -> 0 W'

The pre-fix controller held 220 W through the entire input outage with its status line still reading loop -> 220 W, and layer 1 does not cover that case on a meter_source: off install: no P1 age sensor is published, so the firmware has nothing to veto on, while the heartbeat keeps its watchdog fed. So the old behaviour was not "holds a stale command safely" - it was a failsafe that a repeating meter switched off. test_loop.py asserts both halves.

cycle_floor_s (default 15 s) is a deadline on the gap between cycles, not a second scheduler: every cycle resets it, whichever trigger fired. On a healthy meter it never elapses, so the cycle rate, the write sequence and therefore the per-cycle gain the tuning was measured against are unchanged - asserted in test_loop.py by driving the real loop twice on one binary (a huge cycle_floor_s reproduces the old behaviour exactly) and comparing the commanded values.

The reset is not the only thing holding that up, and the other argument is the sturdier one: the combined cycle rate is max(arrival rate, 1/floor), never the sum. At 1/15 s the floor is strictly slower than the ~1/5 s arrival rate, so even a hypothetical floor racing the arrivals could not exceed the nominal healthy rate. The re-tune is unreachable by construction. ⚠️ That holds only while cycle_floor_s stays above the meter's update interval, and the schema minimum is 5 s - which is exactly the reference meter's interval. Nothing enforces the relationship; validate.py is the obvious home for it and does not have it yet.

Observed over six real minutes on the same rig, one binary, meter held at a literally constant 350.0 W: before, 1 cycle (at startup) and then nothing, the command stuck at 220 W against a 350 W import for the rest of the window. After, 24 cycles, worst gap 15.14 s, and the ordinary PI ramp doing its job - 220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle, rail at t=136 s and flat after. Three minutes with the meter parked at the target instead: 1 cycle before, 12 after, and 19 writes either way - the same 19. Three minutes on a normally-changing meter: 36 cycles and 49 writes on both sides, the same values in the same order. The heartbeat write count never moves; the only writes the fix adds are the ten the loop was supposed to be making all along.

15 s is bracketed, not round.

Below it, ~11 s, and it arises more routinely than a dropped poll. HomeWizardLocalSource polls at 5.0 s against a meter that updates every 4.97 s (NOTES.md:640). Two near-equal periods beat, so roughly once every ~14 minutes the poller steps over an update entirely - a ~10 s gap between changed values on a perfectly healthy meter, plus up to 1 s for the 1 s tick to notice. A failed HTTP poll (retried on the next tick, no backoff) adds another 5 s. The floor sits above the beat-skip so it does not fire on that alone; what it takes to reach 15 s is a beat-skip and a failed poll coinciding.

Above it, 30 s. meter_max_age_s is 30 s, past which there is no reading to evaluate, and the firmware's ingest veto is also 30 s - so the loop is guaranteed to have re-decided at least twice inside any window in which layer 1 might otherwise be the only thing deciding. ⚠️ The default is therefore not independently justified at 15: if the firmware's veto ever moves, this moves with it. Noted beside the constant in main.py.

It is also exactly stale_input_s, this system's existing answer to "how long may we hold without re-deciding".

A floor cycle runs the full law on the same inputs, integrator included. In P1 mode the freshness question is already answered upstream and answered harder

  • past meter_max_age_s the reading is None, which is "inputs missing", which is a P_SAFETY 0 W claim - so a floor cycle there can only ever run on a reading this system already calls fresh. ⚠️ That is transport-conditional: with meter_source: off, read_inputs() takes the grid figure straight from hass.number() with no age gate at all, so a Home Assistant entity that has gone quiet reads as current on that path, with or without this change. Running the full law is still right there - the alternative is a degraded second law reasoning about an age nobody measured - but the floor does not make that path fresh. The integrator advances per cycle, not per second, so bounding the gap bounds the accumulation; integrator_max_w bounds it after that. A gentler second law for floor cycles would be a second set of dynamics nobody can test on this hardware.

⚠️ This is not a freeze detector, and TEL-05 established one cannot be built here: at the converged -10 W target a 1 Wh register needs ~6 minutes to move while the power figure legitimately repeats, so any threshold on unchanged_s false-trips at the exact operating point we run at. Nothing in this change decides whether a repeated reading is true. It stops "the number is the same" from meaning "do not think". The consequence, stated plainly: against a meter genuinely frozen at a wrong value the loop will now correct toward that wrong value rather than hold a stale command, bounded by max_w, the arbiter and the device rating. That was already what happened to a lying meter whose value merely jittered; bit-exact repetition was never a safety property.

DOCS.md's "Saturation is counted in cycles, not seconds" section documented the old behaviour as an accepted deviation. It is qualified, not deleted: the deviation survives (the window is still counted in cycles, and 3 x 15 s is still not the specification's 10 s) but it is now bounded at 45 s instead of open-ended, and the passage's second justification - "nothing accumulates while it is stalled" - is called out as having covered integrator windup and not staleness, which was the actual hazard. The same wrong argument in control.py's saturation comment is corrected too.

TEL-04. meter_source: ha_signed reads a single signed power entity, which is the shape a HomeWizard P1 publishes. Both transports 0.3.0 shipped require two unsigned registers and refuse negatives, so neither fits the meter installed here.

TEL-05. meter_source: homewizard_local polls the meter's own local API directly. This exists because of something the HA paths cannot do: Home Assistant fires no state change for a repeated reading and exposes no arrival signal at all, so sensor.p1_sample_age_s on those transports measures time since the value changed, not since the meter reported. Real captured data has gaps of 42 s and 97 s between changes on a perfectly healthy meter - long enough for a 30 s staleness threshold to command 0 W for no reason. Every HTTP response to the local API is a genuine arrival, so the age means what it says.

Verified on the rig against a literally constant 350.0 W for 70 s - the exact state where the HA path recorded zero samples in 45 s - with 14 arrivals and the age never exceeding the poll cadence.

Set p1_host to the meter's address and meter_poll_s (default 5 s, matching the meter's own ~5 s update). Still defaults to off; nothing changes for an install that does not opt in.

Freeze detection is separate and deliberately not thresholded: a meter answering 200 OK with a stale number is arriving, so no arrival stamp can flag it. The energy registers carry that as unchanged_s, surfaced on the status line for a human to read rather than alarmed on - at a converged -10 W a 1 Wh register needs about six minutes to move, so any threshold would false-trip at the target operating point.

Detail notes from the 0.4.x era — NOT unreleased

⚠️ Retitled with the same correction as the section above: TEL-05 and the entries under this heading shipped long ago. Two headings in one file both claiming "Unreleased" is how a reader ends up believing running behaviour is still pending.

TEL-05. A fourth meter_source, homewizard_local, which polls a HomeWizard P1's own local API (GET /api/v1/data) instead of watching a Home Assistant entity. Set p1_host to the meter's address; meter_poll_s (default 5 s, the meter's own update rate) sets the cadence.

✅ This is the first transport whose sensor.p1_sample_age_s measures when the meter reported, and therefore the first one a firmware watchdog may threshold. Every HTTP response is an arrival: the meter answered, now, with its current reading, and whether the number moved is not consulted. Home Assistant cannot express that at all — a repeated reading emits no state_changed, advances last_reported on neither serialiser, and state_reported is not subscribable ("Event filter is required"). On ha_signed that made a healthy meter under a flat load indistinguishable from a dead one, and our own capture of this house's meter goes 42.2 s and 97.0 s between changes — both past the default meter_max_age_s of 30, i.e. a false trip to 0 W on a meter that is fine. If you have a HomeWizard P1, move to this mode.

Everything TEL-01 established is reused, not re-implemented: ingest timestamping, meter_max_age_s, the clock-recomputed age, the plausibility bounds and the §20 unsigned-decode rejection, and the same split_signed sign convention ha_signed uses. A failed or timed-out poll submits nothing, so it is a missing reading — never 0 W — and it does not reset the age.

Verified on the ENV-01 rig against sim/hwsim.py, steady and with --fault freeze injected. Still defaults to off.

⚠️ An arrival stamp still cannot see a frozen meter, and no arrival detector can: a meter answering 200 OK forever with a stale number is arriving. The local API does expose what the HA path never had — the total_power_*_kwh registers stop advancing — and the transport tracks it as unchanged_s, but that is deliberately not folded into the age and not thresholded: this controller regulates grid power toward ~0 W, and at a converged −10 W the export register needs six minutes to move by its 1 Wh resolution while the power figure legitimately repeats. Thresholding it at 30 s would rebuild the false-trip limit cycle at the exact operating point we aim for. Freeze detection needs the low-power case solved first, separately. It is shown on the status page's P1 line instead — leaving it unthresholded only holds up if a human can read it, so now they can.

TEL-04. A third meter_source, ha_signed, reading one signed Home Assistant entity: positive = import, negative = export. That is the shape a HomeWizard P1 publishes (sensor.p1_meter_active_power), and it is the meter actually fitted here - which neither TEL-01 transport can read, because ha_dsmr needs two unsigned registers and refuses a negative one, i.e. every exporting telegram. Set p1_net_entity, and p1_phase_net_entities for the per-phase capacity-tariff figures on a three-phase connection.

Everything TEL-01 established is inherited rather than re-implemented - the new transport is a subclass of the ha_dsmr one overriding only which entities it wants and how they become a sample. So ingest timestamping, meter_max_age_s, sensor.p1_sample_age_s recomputed against the clock and republished once a second, the plausibility bounds, and unavailable / unknown treated as a missing reading and never 0 W all behave identically across the three sources.

Still defaults to off; an existing install is unaffected until it opts in.

⚠️ sensor.p1_sample_age_s is published on ha_signed, but must not yet be thresholded by the ESP32 stale-input watchdog. On the HA WebSocket paths the age is stamped from state_changed, so it measures time since the value changed, not since the meter reported - and Home Assistant exposes no arrival signal for a repeated reading (no state_changed, no last_reported movement on either serialiser, and state_reported is not subscribable over the WebSocket). Measured on the ENV-01 rig against the real HomeWizard integration. ha_dsmr mostly escapes it because a telegram moves several entities at once; ha_signed has one, so a healthy meter under a flat load is indistinguishable from a dead one. Our own capture has the house meter going 42.2 s and 97.0 s between changes. Raising meter_max_age_s does not fix that, it only chooses which error you get; the fix is an arrival stamp from the meter itself and is a separate ticket. Full detail in DOCS.md.

0.3.0

SAFETY-04. The control law's integrator is now an explicit accumulator, bounded independently of the output clamp instead of inheriting whatever headroom the clamp happened to leave. It also freezes while the inverter is not tracking, rather than continuing to wind up against a command nothing is acting on. integrator_max_w (default 0) governs the bound; 0 means "follow max_w", which is the existing behaviour.

Behaviour is unchanged at the defaults - a 4,928-case equivalence sweep against the previous control law confirms it decides identically at integrator_max_w: 0.

TEL-01. P1 meter ingestion, so a Belgian P1's two unsigned registers (consumption, injection) no longer need a hand-written signed template sensor: the subtraction moves into the add-on, done once and tested. Two transports, chosen with the new meter_source option: ha_dsmr subscribes to the DSMR integration over the HA WebSocket, mqtt_p1 reads a topic. Defaults to off, which keeps the existing meter_entity path untouched - nothing changes for an install that does not opt in.

Enabling it publishes sensor.p1_sample_age_s: seconds since the newest accepted telegram, recomputed against the clock and republished roughly once a second rather than only when a telegram lands. That is deliberate - Home Assistant only pushes a state on change, so a meter sitting at a genuinely constant reading would otherwise look identical to a dead one. Watching the age instead means a frozen meter shows a climbing age, not a flat line. The firmware watchdog subscribes to this exact entity id.

Known limits, both already in DOCS.md: on mqtt_p1, a bridge stuck republishing its last telegram still "arrives", so the age cannot detect that particular failure - prefer ha_dsmr where both are available. And a dead P1 meter takes 45 s to reach 0 W commanded (30 s for meter_max_age_s to call the reading stale, then 15 s of stale_input_s on top), which is meter_max_age_s and stale_input_s stacking, not either one alone.

0.2.1

target_grid_w (default -10 W): what the meter should rest at. The deadband holds any resting point inside it indefinitely, and the meter bills import and export on separate registers, so resting at +14 W import costs 0.34 kWh/day with the loop behaving perfectly. Biasing the target slightly negative moves that residue onto the export register. Configurable in the Configuration tab; see DOCS.md for the trade-off table.

Behaviour is unchanged at target_grid_w: 0.

0.2.0

Precedence between strategies is now a first-class object instead of an if/else ladder, ahead of there being more than three of them.

Every strategy returns a CLAIM each cycle - set ("I want X") or limit ("the result must stay within these bounds") - and arbiter.py resolves them by one rule:

  1. Highest-priority set wins; no claim at all means 0 W.
  2. Then every limit whose priority is >= that set's priority applies, most restrictive first.
  3. Contradictory limits are a BUG: command 0 W and say so.

Clause 2 is why "money outranks maintenance" is now a consequence of the priorities rather than a special case in a Jinja template: the maintenance charge-only limit binds the loop, but will not bind a higher-priority peak shaving claim when one exists.

  • Maintenance shaping (charge-only, cheap-window floor) moved out of the control law. control.py is once again only a controller that tracks the meter.
  • The loop computes from the ARBITER's last output, not its own last wish. If something outranked it, that is what the hardware actually did, and tracking anything else makes it jump when it regains control.
  • Every decision is explainable: "loop -> 0 W, limited by maintenance (charge-only)" now appears in the UI and the log, instead of a bare number.
  • Safety limits (device rating, supervised max_w) bind every strategy including the highest, and are still enforced a second time at the point of writing.

0.1.6

Findings from installing this on a live system, replacing a working YAML implementation. Every one of these was silent - the add-on looked healthy while being completely unable to do its job.

  • run.sh must use #!/usr/bin/with-contenv sh. The HA base images run s6-overlay, which starts services with a SANITISED environment. With a plain shebang, SUPERVISOR_TOKEN is simply absent and every Home Assistant call returns 401 - while homeassistant_api: true makes the permissions look correctly granted. Startup now logs the token length and probes the Core API, so the next person sees it in one line.
  • Bump version: for every change. Supervisor keys the built image by version, so editing source and rebuilding silently reuses the old image. Two fixes appeared not to work because of this.
  • Dependencies come from apk, not pip. Alpine is musl and there are no musl wheels for aiohttp; pip would compile it on the client's Pi.
  • paho-mqtt 1.x and 2.x are both supported. Alpine ships 1.x, which has no CallbackAPIVersion; that raised and took the whole add-on down with it.
  • MQTT can no longer take down control. Publisher construction is wrapped - observability must never stop the controller.
  • MQTT discovery is published from on_connect. paho drops QoS-0 publishes issued before the CONNACK, so announcing straight after connect() published nothing at all while logging "MQTT connected".
  • Repeated failures log at most once a minute. The control loop retries every second; unthrottled warnings rolled the log buffer and destroyed the startup diagnostics needed to debug the 401 above.
  • auto_start works. The store's defaults supplied auto: False, so the fallback to the option could never fire.

Known issue: after deleting the MQTT entities from the registry during development, Home Assistant would not re-adopt them from retained discovery - not even after clearing the retained topics and reconnecting. The add-on publishes correct discovery and live state (verified on the broker); this is an HA-side adoption problem and affects status entities only, never control.

0.1.0

First packaged release. Ports the control loop and the monthly maintenance cycle from the reference Home Assistant implementation into an add-on.

  • Grid-following control: gain/slew/clamp/deadband with anti-windup, all tuned against measured hardware behaviour (see FIELD-GUIDE.md §14).
  • Saturation freeze with the duration term — three consecutive diverging cycles, not one. The instantaneous test fires on every large correction, because the plant itself needs 3-6 s to settle.
  • Monthly maintenance cycle as an ownership state machine: drain / charge / hold, with exactly one writer of the setpoint at any moment.
  • Capacity-tariff awareness: the maintenance charge is capped by quarter-hour peak headroom, and peak shaving outranks the maintenance schedule.
  • Failsafe behaviour: commands 0 W on missing inputs, on stop, and on shutdown. Never replays a stale setpoint - the reference implementation did, and the hardware watchdog cannot catch that.
  • Ingress UI with a commissioning checklist that names problems in words.
  • Optional MQTT discovery for status entities.

Known limits:

  • Home Assistant OS / Supervised only (add-ons cannot run on Container/Core).
  • The inverter protocol is reverse-engineered; no vendor contract.
  • Without the optional RS485 e-stop, nothing covers the host machine dying.