- CarTracker.car_w returns None when the current reading carries no power
(power entity unavailable or in a non-power unit); it can no longer raise
into the control cycle, /status or the MQTT values.
- mode3 E and F are the card state "fault" (EN and NL).
- chargersim gains fault().
Co-Authored-By: Claude <noreply@anthropic.com>
test_pv.py part 6 says only the PV reader's named modules may mention its
material, so chargers.py no longer imports pv.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Read-only: nothing in this change writes to the charger.
- app/chargers.py: ChargerDriver, AlfenHaDriver, UnavailableCharger, ChargerReading, CarTracker
- options ev_charger/ev_current_entity/ev_max_a/ev_phases (default off), Settings group, validator, census
- Car card on Home, unreachable row and notification, two-writer info row, MQTT sensors
- car out of the House tile and the house profile
- tools/chargersim.py charger model, test_ev03.py
Co-Authored-By: Claude <noreply@anthropic.com>
The two fixtures ran their cycles at _SRC_NOW but set rejected_since from the
real clock, so the cycle saw inverter-b live while live_units() saw it stale.
Both now use _SRC_NOW, and a check asserts both clocks agree. run_cycle's
comment no longer claims ctl_cycle.py:49 is the only clock read.
Co-Authored-By: Claude <noreply@anthropic.com>
c_src's telegrams were laid up to one datetime.now(); each cycle() then read
the real clock again (ctl_cycle.py:49). Under --cpus 0.25 a cycle takes ~1.3 s,
so by the 23rd sweep cycle the last telegram was older than max_hold_s (30 s),
the guard counted the gap and filed peak@site. The cycles now run AT the
fixture's own instant. Test only; the exact-set checks are unchanged.
Co-Authored-By: Claude <noreply@anthropic.com>
H-1: one site limit while the pause holds (the period's largest floor, never under this cycle's), so the other pack no longer gives for the house. New live-try test (A 11 %, B 25 %, 90 min at 6.5 kW) red on 07d23d2. M-1: a 45-min rig-shape test that goes red when the settled check is forced True. M-2/L-2: DECISIONS. CHANGELOG line. test_safety84 n2_charge_banked re-pinned (quarters 3349 and 3950 W, aim 3950 W).
Co-Authored-By: Claude <noreply@anthropic.com>
The same diff as f3f9483..07d23d2 (cap, settled rule, tests, DECISIONS). The merge took the release/1.0 tree, so the rounds are applied as one patch on top of the restored #247.
Co-Authored-By: Claude <noreply@anthropic.com>
Restores #247's code on this branch after the release/1.0 merge. The fix rounds follow in the next commit.
Co-Authored-By: Claude <noreply@anthropic.com>
release/1.0 reverted #247 (7bc8ad2). The tree is taken as release/1.0 here; the next two commits revert that revert and re-apply this PR's four fix rounds, so no history is rewritten.
Co-Authored-By: Claude <noreply@anthropic.com>
- SAFETY-136 row: the gain is at 10 s late; at 15 s a rig test sent more.
- SAFETY-111: the cycle needs more than 4 nights; the 36 h limit ends it.
- MAINT-28: rig counts were 393-468 flips per 45 min, not one figure.
- MAINT-26 / MAINT-25: the next try is the first start hour after the wait.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Takes PR #247 (f3f9483) out of release/1.0 so the 19 Nov release ships
MAINT-24 + MAINT-25 without MAINT-28. The rig failed f3f9483
(reports/MAINT-28-test-report.md) and the fix-forward PR #248 review found
a High regression (reports/MAINT-28-fix-review-report.md). MAINT-28
continues on PR #248 after the release.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner 2026-11-13 ("ok max", relayed by the manager): while the pause holds,
the pack in maintenance CHARGE gives at most the largest floor the guard
claimed in the quarter. The cap is now that pack's own part of the floor
(the floor less what the other units are placed at, split without the cap),
the largest in the 15-minute period, kept per unit (`_m28_hi`). 0 W while
the guard holds it at its reserve. test_maint28b: SoC check stated against
the owner-accepted give (0.70 point, measured 0.64); both-packs-able tests
(B on Cheap hours, B on Solar first); per-unit state and the one-slot
arbitrate. test_maint28 unchanged (5925 W). Pins: test_safety84
n2_charge_banked, test_packshare's one-resolve AST pin (a second call with
the same weights).
Co-Authored-By: Claude <noreply@anthropic.com>
test_maint28 quarter bound back to aim + 1 W (now 5925 W; the guard alone landed
5960.1 W): the pack's limit is the largest floor the guard claimed in the 15-minute
period. A pack in peak_guard.held (the guard places its claim on the others) gets
0 W. test_safety84 n2_charge_banked re-pinned again, its banked quarters asserted
under the aim. New test: guard claims on the other pack only.
Co-Authored-By: Claude <noreply@anthropic.com>
Owner go 2026-11-13. The pack in maintenance CHARGE gets a unit limit with hi
= the guard's own floor while the pause holds, at any SoC (replaces the
under-reserve limit). Sim 45 min: A give 2.39 -> 0.02 kWh, SoC 49.0 %, charge
back 4 s. test_safety84 n2_charge_banked re-pinned (192 of 480 rows),
test_maint28 quarter bound to the month peak. Tests: test_maint28b.py.
Co-Authored-By: Claude <noreply@anthropic.com>
Rig FAIL (TEST-23, f3f9483). F-1: the hold ended at each guard step because
grid + site_batt_w added a new meter reading to a battery reading up to 10 s
old. It now ends only when no battery reading may pre-date a step up of its
command (Controller._batts_settled()). F-2: while the pause holds, a pack in
maintenance CHARGE at or under its peak reserve is limited to 0 W, so it gives
only what the guard claims for the peak. Sim: Lag.batt_period_s (a held 10 s
register). Tests: test_maint28b.py. DECISIONS updated.
Co-Authored-By: Claude <noreply@anthropic.com>
homeview.maintenance_runs() ignored backoff_until(); it drew a cycle every
night of the wait. Now no run and a plain line (EN, NL). test_maint25.py.
Co-Authored-By: Claude <noreply@anthropic.com>
The mode trade still lets a SAFETY-73 probe (PROBE_W alone) go on while a pack
is in its maintenance CHARGE phase; test_opt20.py g7 pins it. ch_ch_maint
digest moved (B no longer grid-charges beside A's charge).
Co-Authored-By: Claude <noreply@anthropic.com>
While a pack is in its maintenance CHARGE phase the mode trade files no grid
charge for the other packs (why "cycle", mirror of SAFETY-78). The maintenance
shaping check and charge floor aim at peakguard.quarter_target_w, month peak
included (SAFETY-80). Tests through cycle(): test_maint24.py.
Co-Authored-By: Claude <noreply@anthropic.com>
With battery modes on, a grid charge the peak guard (or a measured headroom)
stops in the first 60 s of a period no longer latches off for the period: it
may start again once the period is 60 s old, if the guard is clear and the
headroom is over START_W. A stop after 60 s latches as before. In a young
period no charge starts while the batteries' give is still falling (over
START_W within 15 s), since the meter may not show that drop yet. The guard
itself is unchanged, so a real over-aim load is cut on the same cycle.
DECISIONS/SAFETY-135-young-period.md, test_safety135.py.
Co-Authored-By: Claude <noreply@anthropic.com>
F1 the on-change case is tested as slow, F2 override and direction checks,
F3 the 3.75 s rule in the texts, F4 the quarter figures and the live note.
No behaviour change.
Co-Authored-By: Claude <noreply@anthropic.com>
On a meter whose readings come 4 s or more apart, the loop runs at half its
gain after a move of 150 W or more, until the meter has fallen by half of the
move or 2 cycles have passed. With readings 10 s late on a 5 s meter the export
falls 44 % over oven, kettle and hob, owner shape, steps; 1-2 s meters are
untouched.
Co-Authored-By: Claude <noreply@anthropic.com>
test_safety118's "size rule is gone" and test_validate's "no numeric
maintenance_* fallback" read app/main.py only; the code they guard can now
sit in app/ctl_*.py, where a regression passed unseen. Both read
main_files.source() for main.py now. Tests only; no app change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>