adminandClaude Opus 5 5d7e275df4 SAFETY-39: slew_w is a ratio to the rail, and gain is what is still wrong
checks / unit (pull_request) Successful in 5m16s
`slew_w: 1000` was derived on 2026-08-22 against a clamp of 1500 W, where
"capping how far the loop can jump ahead of the inverter" was true because the
rail itself bounded the excursion. The live install went to max_w 5000 and the
constant did not move, so the loop crosses its whole output range in 10 s
against a plant NOTES.md §5.10 measured at ~18 s. Measured on the owner's system
2026-09-05 11:43-11:46: a 3.4 kW export drove the setpoint 380 -> 5000 W in five
2 s ticks, the battery to -5154 W past a 5000 VA rating, and the grid from
3.4 kW of EXPORT to 2.8 kW of IMPORT. Nothing was broken; the rail moved.

REPRODUCED FIRST, and one half of it is not reproducible at all. On
plantsim.Plant and on an independent in-repo model: the setpoint stepping a full
1000 W per tick to the rail (48 of 51 export steps), and the meter crossing from
export into import. The -5154 W figure is NOT reproducible in either model,
because both clamp the plant at its rating - so the card's AC "battery no longer
exceeds max_w in simulation" is unfalsifiable and was rewritten rather than met.

THE DELIVERABLE IS THE RELATIONSHIP.
  SLEW_RAIL_FRAC = LOOP_TICK_S / PLANT_SETTLE_S = 2 s / 18 s = 1/9
  slew_w = 0 now means FOLLOW THE RAIL - SLEW_RAIL_FRAC * max_w - exactly as
  integrator_max_w = 0 already means follow max_w. It is the shipped default:
  222 W at max_w 2000, 556 W at 5000, 1067 W at a ~9600 W two-inverter site.
  validate.py rule 10 refuses an explicit value faster than that, graded against
  sum(unit_caps(opts)) - the roster sum, i.e. Controller.site_max_w - so a
  second inverter moves the bound with no operator action.

VERIFIED BY BREAKING IT: restoring slew_w 1000 at max_w 5000 is refused, and the
refusal names the rail, the crossing time, the measurement and what to do.
Equality, one watt of slack, the live interim 400 and slew_w 0 at every rating
all still start.

GAIN IS THE CONSTANT THAT IS STILL WRONG, and it is NOT changed here. Over 51
export steps the over-absorption is FLAT in slew (958 W at 1000, 1081 W at 250)
and monotone in gain (987 W at 0.6, 876 at 0.3, 435 at 0.2): slew_w bounds the
OUTPUT, while the integrator moves gain*error per cycle and reaches a 5000 W
rail in under three ticks whatever the slew is. Two control-law constants moving
in one release on a running house makes the next measurement uninterpretable.

⚠️ N=2: the site rail becomes sum(max_w) ~ 9600 W (inverter B FROM DATASHEET AND
SERIAL, not measured, and sim/plantsim.py's INVERTER_B is A copied), and the
enforced ratio produces 1067 W there automatically. But a growing rail LOOSENS
this bound, and the >= 900 W symptom goes stale at N=2 the same way the constant
did - both stated in the record rather than left to be discovered.

Nothing reached the inverter. The live install still runs the interim slew_w 400
applied by hand on 2026-09-05, which rule 10 accepts unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-06 01:10:15 +02:00
glenn schrooyenandClaude Opus 5 7b4877d56d TEST-15: purge the bytecode cache before a mutation run, not after
checks / unit (pull_request) Successful in 3m35s
FCST-03's developer reverted `self.provisional` to `here.provisional`, re-ran,
and reported the mutation as a survivor. It was not one. CPython validates a
cached `.pyc` on (source size, source mtime truncated to whole seconds), and
that edit moved neither number - same length, same second - so the interpreter
loaded the bytecode it already had. Disassembly settled it at the time: the
source read `here`, the running code loaded `self`. A mutation run had graded
code that was not there, with no error and exit status 0.

This does not make the results already on the record wrong. It makes them
UNVERIFIED, and that distinction is the whole card - so nothing here re-runs a
campaign and nothing here quietly assumes the old numbers hold.

REPRODUCED, THEN CLOSED. test_bytecode.py builds a real package whose two
return values are the same length, imports it in a real subprocess, rewrites it
inside the same second (retrying until both writes land in one whole second -
milliseconds, no sleep) and reads back which value ran. Part 1 shows the
interpreter running SELF off a file that says HERE.

AND THE TWO OBVIOUS MITIGATIONS DO NOT WORK. Measured, not read off
documentation: `python3 -B` and PYTHONDONTWRITEBYTECODE=1 are write-side only.
Neither stops an EXISTING stale .pyc being read, and a mutation run always has
one, because the previous run wrote it. Part 2 grades both still running the old
code. The advice in test_control.py's coverage audit led with `-B`; it is
corrected here - the purge is the half that works, and `-B` earns its place by
keeping THIS run from leaving a cache for the NEXT edit to inherit.

NO SLEEP ANYWHERE. One-second mtime resolution is the mechanism, not the enemy.
Waiting it out would slow every run down and would still only cover the edit
somebody remembered to slow down.

THE HARNESS. tools/mutation_run.sh purges, prints a sha256/byte fingerprint of
every app/*.py it is about to grade - so a mutation report can say WHICH source
produced it, which is the reviewer's addition to this card - runs each suite
under `python3 -B`, refuses a tree with no test_*.py (CI-01's rule, for CI-01's
reason), and fails if a cache appears during the run. It takes the tree as an
argument so the infra repo's replay harnesses can call it without being moved.

WHERE IT IS SAID (AC 2). MUTATION.md carries the mechanism, the measurement,
the reporting rules and the survey, and every one of the 16 suites now points at
it from its docstring. That list is DERIVED FROM THE TREE by test_bytecode.py
part 5, so a new suite that joins this directory without the pointer is red -
the same failure shape CI-01's file glob exists to prevent.

CI WAS ALREADY IMMUNE, AND IS DESCRIBED THAT WAY (AC 4). Verified rather than
reasoned: with the checkout bind mounted `-v "$WS:/w:ro"` the interpreter writes
no __pycache__ into the tree at all, and it fails SILENTLY - no error, exit
status 0 - while the same probe on a writable mount produces one. Each job also
rm -rf's its workspace and clones afresh, so nothing crosses between jobs on the
shared runner. PYTHONDONTWRITEBYTECODE=1 is added as belt and braces only: the
`:ro` is one character wide and the next person debugging a write will be
tempted by it. Part 6 grades both ON THE DOCKER COMMAND LINE rather than on the
file - the first draft searched the whole workflow and stayed green after the
flag was deleted, because the comment explaining it still named it.

THE SHIPPED ADD-ON IS NOT AFFECTED and the question is closed:
goodwe_controller/Dockerfile has set PYTHONDONTWRITEBYTECODE=1 since it was
written. There is no deploy-side finding.

THE SURVEY (AC 3), in MUTATION.md, scoped BY THE PROPERTY. The defect is
one-directional - a mutation that never took leaves the suite green, so stale
bytecode manufactures SURVIVORS and cannot manufacture a red - which puts every
"all red, no survivors" claim in the window out of scope, along with mutations
executed in-process (SAFETY-07's B1/B2/B3, test_peakguard parts 7 and 10, where
no source file is edited) and everything run after the purge discipline landed
on 2026-08-31 (SAFETY-24, SAFETY-26, OPT-04, FCST-03's re-run). What is left is
the recorded SURVIVORS from source-edit runs before that date. Two were re-run
here under the harness and both still stand: TARIFF-01's record_block() ignoring
its policy argument, and SAFETY-03's abs() on the clamp limit - 15 suites green
each, on the tree as it stood. The rest are labelled still-unverified rather
than assumed or re-run; each is one harness run to close, and the moment to
spend it is when somebody next touches that module.

OUT OF SCOPE AND RECORDED: the infra repo's sim/ replay harnesses import the
add-on and write bytecode into both trees (goodwe/sim/__pycache__ exists today),
so SAFETY-02's headline replay carries the same exposure. mutation_run.sh takes
a tree argument for exactly that, but the change belongs in that repo and some
of those harnesses want the rig.

RED AND GREEN. Every new check was broken and watched fail: the purge commented
out of the harness turns part 4 red (and its non-vacuity probe already proves
the fixture would mis-grade without it); one docstring pointer removed turns
part 5 red naming the file; `:ro` and the `-e` flag removed from the workflow
turn part 6 red. Full suite green, 16 files, in the CI image on a read-only
mount - the shape the runner uses.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-01 02:07:09 +02:00
glenn schrooyenandClaude Opus 5 aae74d7571 SAFETY-12 review: name the safety claim that could not fire, and fix two figures
Review fixes.

A. test_loop.py takes 73 s, not the ~35 s claimed in three places. That number
is the whole defence against a future developer deleting a slow test, so it was
understated by 2x in exactly the place it matters. Corrected - and it is now
~95 s (measured 93 s), because this commit adds the scenario below rather than
trimming windows to make an inconvenient number smaller. Both call sites carry
an instruction to re-measure if the windows change.

B. "242 checks" was test_p1's own count quoted as the total for all five
suites. The real figure is 395 across the five, plus 14 here.

And the finding this PR should have led with. stale_input_s and the
`inputs missing -> 0 W` claim both live INSIDE cycle(), so pre-fix, on a meter
whose value happened to repeat, that claim could not fire at all. Constant
meter, SoC entity dying at t=4 s, one binary:

  pre-fix   final target 220.0 W, reason 'loop -> 220 W'
  post-fix  final target   0.0 W, reason 'safety -> 0 W'

The old controller held 220 W through the whole input outage with its status
line still reading loop -> 220 W, and layer 1 does not cover that on a
`meter_source: off` install - no P1 age sensor is published, so the firmware has
nothing to veto on, while the heartbeat keeps its watchdog fed. The pre-fix
behaviour was not "holds a stale command safely"; it was a failsafe a repeating
meter switched off. Asserted in test_loop.py, both halves.

Three points of reasoning tightened, none of them wrong before:

- the re-tune is unreachable by construction, not merely by the reset: the
  combined cycle rate is max(arrival rate, 1/floor), never the sum, and 1/15 s
  is strictly slower than the ~1/5 s arrival rate. That holds only while the
  floor exceeds the meter's update interval - and the schema minimum of 5 s is
  exactly the reference meter's interval. Flagged for validate.py, not fixed
  here.
- the ~11 s lower bracket is not only a dropped poll: a 5.0 s poller against a
  4.97 s meter beats, so about every 14 minutes the poller steps over an update
  entirely. Reaching 15 s takes a beat-skip AND a failed poll.
- the "freshness is decided upstream" guarantee is transport-conditional. On
  `meter_source: off` the grid figure comes straight from hass.number() with no
  age gate. Running the full law is still right; the claim is narrower than it
  was stated.

The 15 s default is not independently justified - it rests on the firmware's
30 s ingest veto and moves if that ever does. Said beside the constant.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 21:14:58 +02:00
glenn schrooyenandClaude Opus 5 88cd97cc7a SAFETY-12: the loop thinks on a clock, not only when the number moves
run_control() ran cycle() only when the meter value differed from the previous
poll. A meter that repeats a value therefore ran no control cycles at all -
while the heartbeat kept re-emitting the last command and the firmware kept
putting it on the wire every 2 s. Layer 1 stayed fed and every indicator read
healthy, so a command computed from an old reading went on being executed
through whatever the load did next. TEL-05 measured it: 70 s at a literally
constant 350.0 W, 14 arrivals, zero cycles.

cycle_floor_s (default 15 s) is a deadline on the GAP between cycles, reset by
every cycle whichever trigger fired - not a second scheduler. On a healthy meter
it never elapses, so the cycle rate and the commanded sequence are unchanged;
test_loop.py asserts that by driving the real loop twice on one binary (a huge
cycle_floor_s reproduces the old behaviour) and diffing the writes.

15 s is bracketed: above the ~11 s worst gap on a merely-unlucky healthy meter
(~5 s arrivals, 1 s detection, one dropped poll retried on the next tick), below
meter_max_age_s and the firmware's 30 s ingest veto, and equal to stale_input_s.

A floor cycle runs the full law. Freshness is already decided upstream - past
meter_max_age_s the reading is None, which is a P_SAFETY 0 W claim - and the
integrator advances per cycle, not per second, so bounding the gap bounds the
accumulation.

Not a freeze detector: nothing here decides whether a repeated reading is true.
DOCS.md's "accepted deviation" passage is qualified rather than deleted - the
window is now bounded at 3 x cycle_floor_s instead of open-ended, and its
"nothing accumulates while it is stalled" argument is called out as having
covered windup and not staleness. Same correction in control.py's comment.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
2026-08-28 20:29:16 +02:00