EV-05 round 7: Solar watches while not writing; shadow start writes nothing
Review of b4a222f, brief v6 Expected 11 (owner 2026-11-18):
- Solar keeps watching for another writer while it is not writing (Stop,
  shadow, safety stop), so hold is true for every reader: the exit, the
  shutdown, the peak alarms, and Start afterwards.
- car_solar_can_cut() also needs Solar to be writing: the peak alarms stand
  as in Off and the quarter is banked.
- A start or restart in Solar with shadow on writes nothing (the
  not-writing 0 A is owed only when Solar had the charger before).
- Once that exit 0 A is taken, nothing more is written, shutdown included.

Tests: alarm rows for Stop, shadow on and safety stop against an Off twin;
shutdown after another writer in shadow and Stop; a start in shadow with the
car already charging; Start after a stop; two variants inside the 30 s watch.

Co-Authored-By: Claude <noreply@anthropic.com>