glenn schrooyenandClaude Opus 5 f109153216
checks / unit (pull_request) Successful in 6m58s
SAFETY-44: ship only what this suite can measure, and split the two clauses it cannot
⚠️ REVIEW FOUND THE INJECTIVITY CHECK INERT IN THE SAME WAY M12's FIRST DRAFT
WAS, three paragraphs below the comment diagnosing it. Removing the whole
mechanism left 28/28 GREEN: part 5's two destinations are `sign_reason` and
`sign_tripped`, DIFFERENT bare keys, which can never contend. The
`len(_dests) >= 2` precondition was true and established nothing - "not
asserting over an empty list" was correct, "this run can exercise injectivity"
was not.

Review also measured a second, narrower silent loss: `moved_to` accepts a
destination regardless of whether the TRANSITION put the value there, so a
roster unit already latched in its own right is a free suppression slot. A build
deleting `old-a` while renaming `old-b` -> `shed` reported exit 0, NO FINDINGS,
with `old-a` "migrated" into a key that already held True.

⚠️ I WROTE BOTH ONE-LINE FIXES AND HAVE REVERTED BOTH, because THIS SUITE
CANNOT MEASURE EITHER. Three attempts, three different ways of proving nothing:

  1. assert injectivity over part 5's real destinations
     -> passes with the entire mechanism deleted (non-contending bare keys)
  2. build a dedicated fixture for the two-claimant case
     -> discriminates NOTHING: both snapshots read one state file, so nothing
        vanishes and there are no migrated lines with the clause or without it
  3. rebuild M12's fixture so the destination is transition-made, to reach the
     provenance case
     -> ⚠️ DISARMED M12 FOR THE NARROWING. All three clause-removals came back
        GREEN at once, and the control I had measured RED last round was gone.

⭐ (3) IS WHY THIS IS A SPLIT AND NOT A JUDGEMENT CALL. A later fix to the same
function silently disarmed the control for an earlier one, and I saw it only
because I re-drove the removal rather than trusting the suite's exit code.
Shipping two more unmeasured clauses into the rehearsal instrument, on a card
whose entire subject is checks that cannot reach what they name, would be the
fourth inert artifact in one PR. They go on their own card, with review's
measurements as the starting evidence and the fixture built BEFORE the fix -
which is the ordering that worked for M12 and failed every time I inverted it.

⚠️ AND THE SPLIT IS SAFE, WHICH IS WHY IT IS AVAILABLE. Both remaining holes are
in the REHEARSAL TOOL, not the controller. The round-2 narrowing guarantees a
suppressed key is always OFF the roster, so no roster unit loses protection;
what is left is rollback-view/history mis-reporting on a tool an operator runs
before commissioning. Nothing here can disarm a latch on a live site, and
inverter B goes in on ~2026-09-12. Review offered this split explicitly.

M12's PRECONDITION IS STRENGTHENED, because the exit code could not carry it.
It now requires the shipped tree to be clean AND to not already report the
finding the mutation exists to produce. The first draft passed on exactly that
gap: the fixture's own litter made the run red and nothing separated the two.

Re-driven after the revert, on the round-3 fixture:

    shipped                                   exit 0
    `vanished_unit not in after.units` gone   ⚠️ exit 1

28/28 files pass. The controller half is unchanged since d1b7e3f and review has
no further concerns about it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 18:44:38 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
18 MiB
Languages
Python 98.1%
JavaScript 1.2%
CSS 0.3%
Shell 0.2%
HTML 0.2%