Claude Opus 5 e06906d65f ARCH-02: rehearse the flat-to-roster switch, and it comes up disarmed
Nothing had ever run the real `Controller` through the transition inverter B's
commissioning performs on 2026-09-12. `tools/rehearse_roster.py` does, over a
COPY of a state file given as an input path, and reports the difference: every
store key that moved, appeared, vanished or was STRANDED under a name no
machine reads; every entity id before and after with orphans named; and whether
the maintenance history MAINT-05 moved once survived being moved again.

⭐ WHAT IT FOUND, AND IT IS SAFETY-44's ANSWER. A store that ran pre-DEV-02 flat
and declares a multi-inverter roster comes up with its SAFETY-02 latch DISARMED
unless the first roster entry happens to be called `inverter-a`.
`Controller.__init__` hands `migrate_unit_keys()` the hardcoded `UNIT_A`, so the
latch lands in `unit/inverter-a/sign_tripped`; a roster of ["garage","shed"]
reads `unit/garage/sign_tripped`, which is absent. And `_grade_store_migration()`
- the guard written for exactly this - sees the migration's OWN misdirected key
satisfy its `namespaced_latched` test and returns without re-arming. Measured,
not argued: the file says `sign_tripped: true`, no inverter is latched, nothing
is held at 0 W. The same state file onto a roster whose first entry IS
`inverter-a` comes up latched, so the finding is attributable to the name.

The staged upgrade reaches it too: the flat start stamps `schema_version`, and
the roster start's migration then takes its early return.

⚠️ NO RUNTIME CODE IS CHANGED HERE. The fix to `migrate_unit_keys()` belongs to
SAFETY-44 reopened as a defect, shown red before it; this commit is the
instrument that shows it red.

THE CHECK CAN FAIL, AND WAS SEEN TO. `test_rehearse.py` establishes two CLEAN
CONTROLS first - two transitions the shipped code gets right, on which the
harness must say nothing - and then breaks the shipped migration and the
entity-id composition six ways in a private copy of the tree, requiring each to
turn its control from green to red WITH THE RIGHT FINDING NAMED. One mutation
is required to SURVIVE, with the reason written down. The synthetic state
carries maintenance history and a legacy-shaped latched `sign_tripped` with no
`schema_version` beside it, because state built by the happy path cannot detect
a migration that only mishandles legacy shapes.

⚠️ THE FIRST DRAFT OF THE HARNESS HAD HABIT 4 IN IT and its own battery caught
it - MUTATION.md's thirteenth instance, third in an instrument. The entity diff
composed both sides with the same build, so renaming the MQTT device moved every
id equally and it reported "no orphans" about a change that orphans everything.
`--live-entities` is the fix: a reference that does not move with the code.

THE RETREAT is supported and does not corrupt state - the flat rollback view
keeps the latch and the first pack's history live - but it orphans eight HA
entities, and the ROUND TRIP is not supported: a maintenance cycle completed
while rolled back is discarded on re-advance. Stated in DOCS.md as a decision.

Fetching /data/state.json, the options blob and the entity list are OWNER STEPS
and are written down. ⚠️ Nothing here was run against real state and nothing
here claims to have been.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
2026-09-08 13:15:05 +02:00

GoodWe RS485 Controller — Home Assistant add-on repository

Replaces a GoodWe battery inverter's vendor controller with a local one: holds net grid exchange at zero by emulating the inverter's smart meter over RS485, and runs the monthly battery maintenance cycle the vendor box was doing.

repository.yaml            add-on repository metadata
goodwe_controller/         the add-on
  config.yaml              manifest + options schema (the per-site config form)
  app/                     the controller
    control.py             the control law — pure functions, no I/O
    maintenance.py         the monthly cycle state machine
    hass.py                Supervisor/Core API access
    store.py               persistent state in /data
    mqtt.py                optional status entities
    web.py                 ingress UI — routes only, status and configuration
    config_page.py         the configuration page's markup, style and script
    configui.py            its field model, built from the Supervisor's own
                           schema + translations — owns no key, label or rule
    selfconfig.py          reading and writing this add-on's own options,
                           with the validate-first / compare-and-swap gate
    main.py                orchestration, heartbeat, failsafe behaviour
  test_control.py          runnable checks — no framework needed
  test_maintenance.py      runnable checks — walks a full cycle in fake time
  DOCS.md                  the add-on's documentation tab
  MUTATION.md              how to run a mutation so the result means something
  tools/mutation_run.sh    the mutation harness - purges bytecode, then grades
  tools/supervisor_selfapi_probe.py  what the Supervisor really permits and
                           returns, run against its own release image
firmware/goodwe-master.yaml  ESPHome config for the T-CAN485
estop/rs485_log.py           optional RS485 e-stop / bus witness
docs/GoodWe-RS485-Field-Guide.pdf  the guide techs carry (10pp, A4)
docs/build_guide.py          its single source - rebuilds the HTML and PDF
FIELD-GUIDE.md             how to edit and rebuild the guide

Picking this up after a break? Read HANDOVER.md first — current state, what is known broken, and what to do next.

Install

Settings → Add-ons → Add-on store → ⋮ → Repositories → add

https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon

then install GoodWe RS485 Controller.

⚠️ The repository must be PUBLIC for this to work. Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy goodwe_controller/ into the machine's /addons/ folder, then ha store reload — it appears as a Local add-on.

⚠️ Bump version: in goodwe_controller/config.yaml for every change. Supervisor keys the built image by that version, so without a bump it silently reuses the old image and your fix appears not to work — on your bench and on every client's machine.

Requires Home Assistant OS or Supervised. Add-ons cannot be installed on HA Container or Core.

Read this first

The inverter holds its last command forever. It has no meter-timeout of its own — a controller that dies mid-command leaves the battery running until a human intervenes. Measured on real hardware: 5 kW of discharge held for 113 seconds after a controller went silent.

Three layers exist because of that, and only the third covers the Home Assistant machine itself dying:

  1. ESP32 watchdog — no fresh setpoint for ~30 s → command 0 W, and keep commanding it.
  2. Wind-down before firmware updates — 0 W written before the update starts.
  3. RS485 e-stop (optional) — writes 0 W after 30 s of total bus silence.

Sites sold without the e-stop must have the acknowledgement in FIELD-GUIDE.md §10 signed.

Development

The control law and the maintenance machine are pure Python with no Home Assistant imports, so they run anywhere:

cd goodwe_controller
python3 test_control.py
python3 test_maintenance.py

Both must pass before shipping any change. To prove a check bites - the way almost every claim in this repository was established - mutate the module and run tools/mutation_run.sh, which clears __pycache__ first. It is not optional: a same-size edit reverted inside one second leaves CPython reusing the old bytecode, and the run grades code that is not there. goodwe_controller/MUTATION.md has the mechanism, the measurement, and what the flags do not do. They are not unit-test theatre — each assertion corresponds to a rule whose absence produced an observed failure on real hardware, and the comments in control.py say which.

Compatibility

Check the serial number, not the model name. Characters 6-8 of the serial are the platform tag:

tag platform verdict
ESU EMU ESA BPS BPU EMJ IJL 105 — ES/EM/BP, AA55-era meter bus supported
SPB SPN 745 — SBP G2 (GW…-SBP-20) no
ESN ESC 745 — ES G2 (GW…-ES-20) no
ETU EHU BTU … 205/745/753 — ET/EH/BT hybrids no
SDT DST MSU NSU … PV-only inverters — no battery to control no

A "-20" or "G2" suffix means a different platform with a different meter protocol. The tags come from the goodwe library's PLATFORM_105_MODELS, which is also what Home Assistant's own integration uses to pick a protocol.

  • GoodWe ES / BP family inverters (AA55 / RS485 meter-bus generation)
  • The protocol is reverse-engineered. There is no vendor contract, and a firmware change on GoodWe's side could break every installation at once. Say so when you sell it.
S
Description
No description provided
Readme
27 MiB
Languages
Python 98%
JavaScript 1.3%
CSS 0.3%
Shell 0.2%
HTML 0.2%