Files
goodwe-addon/goodwe_controller/DECISIONS
glenn schrooyenandClaude 88ab8a50e3
checks / unit (pull_request) Successful in 56m44s
infra-pin / fresh (pull_request) Successful in 1s
SAFETY-125: a grid charge counts a late meter reading's seconds; the guard row says "over" when it is
A meter reading late near a quarter's end left seconds the projection did
not count (SAFETY-99), and charge_headroom_w() read them as room: the cheap
run (and price trading, and the N=2 maintenance charge) went back to full
power in the quarter's last seconds and the quarter could land over a banked
month peak or the cap. peakguard.charge_room_w() counts those seconds at the
held reading for the charge only; the guard's floor is unchanged.

The guard row said "idle, heading for 5 814 W, under this month's 5 413 W
peak". Over the limit at the current rate the row and the month-peak line
now say so, and that the grid charge is cut back.

Version 0.19.2, CHANGELOG, DECISIONS. test_safety125.py new; the lag pins
in test_price_run_fixes.py and test_opt20.py and the AST pin in
test_arbitrage.py follow the change (see the pull request).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-29 02:08:38 +01:00
..